Electronic Vacuum Regulator. How to Order ITV S 5. Monitor output

Size: px
Start display at page:

Download "Electronic Vacuum Regulator. How to Order ITV S 5. Monitor output"

Transcription

1 Electronic Vacuum Regulator Series ITV29/29 How to Order [Option] RoHS ITV 29 2 S 5 Pressure range 9.3 to 8 kpa Power supply voltage 24 VDC to 5 VDC Note) Communication models are available only for 24 V DC. CE compliant Q CE compliant Pressure display unit 5 kpa Note) For the communication models, CC, DN, PR and RC, only is available as it does not have a display. Input signal/ Communication model Current type 4 to 2 ma DC (Sink type) Current type to 2 ma DC (Sink type) CC DN PR RC Voltage type to 5 VDC Voltage type to VDC Preset input CC-Link DeviceNet PROFIBUS DP RS-232C communication Monitor output Analog output to 5 VDC Switch output/npn output Switch output/pnp output Analog output 4 to 2 ma DC (Sink type) None Cable connector type S L N Straight type 3 m Right angle type 3 m Without cable connector Note) Order communication cable (other than RS-232C) separately. See below. Bracket B C Without bracket Flat bracket L-bracket Port size 2 /4 Thread type N T F Rc NPT NPTF G For communications cables, use the parts listed below (refer to the catalog [M8/M Connector] CAT.ES-73 for details) or order the product certified for the respective protocol (with M connector) separately. Application Communication cable part number Remarks CC-Link compatibility PCA (Socket type) Dedicated Bus adapter supplied PCA with the product. DeviceNet PROFIBUS DP PCA (Socket type) PCA (Socket type) compatibility compatibility PCA PCA T-branch connector not supplied. T-branch connector not supplied. Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA Main Office: (65) Outside Local Area: (8)

2 Series ITV29/29 Standard Specifications Stepless control of vacuum in proion to an electrical signal Piping/Wiring Diagram Power supply and input signal (VDC, ma DC) VAC Vacuum pump, Ejector ITV29 OUT Tank Set (Vacuum) Model Voltage Power supply Current consumption Note ) Minimum supply vacuum Maximum supply vacuum Set range Note 2) Current type Input signal Voltage type Preset input Current type Input Voltage type impedance Preset input Output signal (Monitor output) Linearity Hysteresis Repeatability Sensitivity Temperature characteristics Output Accuracy display Units Ambient and fluid temperature Enclosure Note 7) Weight Note 4) Analog output Switch output ITV29 ITV29 24 VDC ±% to 5 VDC Note 6) Power supply voltage 24 VDC type:. A or less Power supply voltage to 5 VDC type:.8 A or less Set 3.3 kpa kpa.3 to 8 kpa 4 to 2 ma DC, to 2 ma DC to 5 VDC, to VDC 4 points (Negative common) Note 3) 25 Ω or less Approximately 6.5 kω Power supply voltage 24 VDC type: Approximately 4.7 kω Power supply voltage VDC type: Approximately 2. kω to 5 VDC (Load impedance: kω or more) 4 to 2 ma DC (Sink type) (Load impedance: 25 Ω or less) Output accuracy within ±6% (Full span) NPN open collector output: Max. 3 V, 8 ma PNP open collector output: Max. 8 ma Within ±% (Full span) Within.5% (Full span) Within ±.5% (Full span) Within.2% (Full span) Within ±.% (Full span)/ C ±2%F.S. digit kpa Note 5) Minimum display: to 5 C (No condensation) IP65 35 g Note ) The minimum supply vacuum should be 3.3 kpa less than the maximum vacuum setting value. Note 2) 4 to 2 ma DC is not possible with the 2-wire type. Power supply voltage (24 VDC or to 5 VDC) is required. Note 3) Value for the state with no over current circuit included. If an allowance is provided for an over current circuit, the input impedance varies depending on the input power supply. This is 35 Ω or less for an input current of 2 ma DC. Note 4) Either analog output or switch output must be selected. Furthermore, when switch output is selected, either NPN output or PNP output must also be selected. Use caution that the preset input type is not equipped with an output signal function. Note 5) Please contact SMC regarding indication with other units of. Note 6) For communication models, the maximum current consumption is.6 A or less. Note 7) For communication models, add roughly 8 g to the weight ( g for the PROFIBUS DP). Communication Specifications (CC, DN, PR, RC) Model Protocol Note ) Version Communication speed ITV -CC CC-Link Ver. 56 k/625 k 2.5 M/5 M/ M bps Configulation file Note 2) I/O occupation area 4 word/4 word, 32 bit/32 bit (input/output data) (per station, remote device station) Communication data resolution bit (496 resolution) Fail safe HOLD Note 3) /CLEAR (Switch setting) Terminating resistor ITV -DN DeviceNet Release2. 5 k/25 k/5 k bps EDS 6 bit/6 bit bit (496 resolution) HOLD/CLEAR (Switch setting) Note ) Note that version information is subject to change. Note 2) Configulation files can be downloaded from the SMC's website: Note 3) The output HOLD value when a CC-Link communications error occurs can be set based on the bit area data. ITV -PR PROFIBUS DP DP-V 9.6 k/9.2 k/45.45 k k/87.5 k/5 k.5 M/3 M/6 M/ M bps GSD 6 bit/6 bit bit (496 resolution) CLEAR Built into the product (Switch setting) ITV -RC RS-232C 9.6 kbps bit (4 resolution) HOLD 35 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA Main Office: (65) Outside Local Area: (8)

3 Electronic Vacuum Regulator Series ITV29 Working Principle Working Principle Power supply Input signal q Vacuum r Diaphragm Pressure display i Control circuit Output signal w Atmospheric Atmospheric u Pressure sensor e Pilot chamber When the input signal increases, the vacuum solenoid valve q turns ON, and the atmospheric w turns OFF. Because of this, VAC. and the pilot chamber e are connected, the in the pilot chamber e becomes negative and acts on the top of the diaphragm r. As a result, the vacuum valve t which is linked to the diaphragm r opens, VAC. and OUT. are connected, and the set becomes negative. This negative feeds back to the control circuit i via the sensor u. Then, a correct operation works until a vacuum proional to the input signal is reached, and a vacuum is obtained which is always proional to the input signal. Block Diagram VAC. (Vacuum pump, etc.) ATM (Atmospheric ) t Vacuum valve OUT. (Set ) y Atmospheric valve Input signal + t Control circuit q Vacuum w Atmospheric VAC. u Pressure sensor r Diaphragm Pilot valve Set Series ITV29 Linearity Hysteresis Repeatability. Output (kpa) Output deviation factor (% F.S.).5.5 Return Out Output deviation factor (% F.S.) Pressure Characteristics Output deviation factor (% F.S.) Set point.5.5 Input signal (% F.S.) Set : 2 kpa Set (kpa) Input signal (% F.S.) Count Flow Characteristics Supply vacuum : kpa Flow characteristics measurement conditions Exhaust flow rate of the vacuum pump used for measurement: 5 l/min (ANR) Inlet vacuum : kpa (When outlet flow rate is l/min (ANR)) Maximum flow rate: 32 l/min (ANR) (With inlet vacuum at 39 kpa) VAC. side (Supply ) (kpa) Flow rate (l /min(anr)) Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA Main Office: (65) Outside Local Area: (8)

4 Series ITV29 Dimensions ITV29 Flat bracket Note) Do not attempt to rotate the cable connector, as it does not turn. Right angle type (4-wire) Straight type (4-wire) x ø7 Mounting hole 52 (33) 4 Connector.5 M5 x.8 Breathing hole 99 (53) 9 ATM. (Atmospheric ) OUT (Set ) Flat bracket assembly KT-ITV-F2 (Option) VAC. (Vacuum ) x 4 x M5 x.8 thread depth 6 mm through L-bracket 4 x R (8.5) L-bracket assembly KT-ITV-L2 (Option) Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA Main Office: (65) Outside Local Area: (8)

5 Electronic Vacuum Regulator Series ITV29 Dimensions (CC-Link, DeviceNet, PROFIBUS DP and RS-232C) CC-Link/ITV29-CC (53) Communication cable connection thread (Socket type) Power cable connection thread BUS adapter Communication cable connection thread DeviceNet /ITV29-DN Communication cable connection thread Power cable connection thread M5 x.8 36 M5 x.8 6 ATM. OUT VAC. ATM. OUT VAC. 2 x 2 x PROFIBUS DP/ITV29-PR Communication cable connection thread (Socket type).5.5 (6) Communication cable connection thread 9.5 RS-232C/ITV29-RC Communication cable connection thread Power cable connection thread 8.5 M5 x.8 36 M5 x.8 6 ATM. OUT VAC. ATM. OUT VAC. 2 x 2 x With power cable connector ITV29- CC DN PR RC common dimensions Straight type (4-wire) Right angle type (4-wire) (33) Note) Do not attempt to rotate the cable connector, as it does not turn. Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA Main Office: (65) Outside Local Area: (8)

6 Series ITV29 Accessories (Option)/Part No. Description Flat bracket assembly Part no. KT-ITV-F2 L-bracket assembly Power cable connector Straight type 3 m Right angle type 3 m Bus adapter (CC-Link model only) KT-ITV-L2 P P EX9-ACY-MJ Dimensions Flat bracket L-bracket x ø x ø4.5 4 x ø5.5 (8.5) x ø4.5 4 x ø x R Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA Main Office: (65) Outside Local Area: (8)

Electronic Vacuum Regulator. Standard Specifications. Model Voltage

Electronic Vacuum Regulator. Standard Specifications. Model Voltage Electronic Vacuum Regulator Series ITV9/9 Stepless control of vacuum in proportion to an electric signal Straight type Piping/Wiring Diagram (VDC, madc) Vacuum pump, Ejector ITV9 Right angle type Tank

More information

Series 10-ZSE30A(F)/10-ISE30A

Series 10-ZSE30A(F)/10-ISE30A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High-Precision Digital Pressure Switch Clean series For positive For vacuum/ compound Rated range ISEA 0.1 to 1 MPa How to Order 10 ISEA 01 N M 01 N01 C4H

More information

Series 10-ZSE80/10-ISE80

Series 10-ZSE80/10-ISE80 Series 0-ZSE80/0-ISE80 RoHS -Color Display Digital Pressure Switch For General Fluids Directional Control Valves For positive 0 80 For vacuum/ compound 80 80F N P B R T S V Rated range Symbol -X50 Clean

More information

Base Mounted Plug-in Unit

Base Mounted Plug-in Unit For details about certified products conforming to international standards, visit us at www.smcworld.com. 000 Plug-in Unit SI unit COM N V V C C C6 M CM 6 B B B6 B M 000 Manifold model Plug-in unit Stations

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

Optimising controls Vacuum switches

Optimising controls Vacuum switches Vacuum switches, pneumatic Converts a vacuum level to a pneumatic signal. Vacuum-actuated membrane linked to a pneumatic switch. Available preset or with adjustable vacuum level. Unit Value Feed pressure,

More information

Valve Island with Electronic I/O

Valve Island with Electronic I/O Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

MM1/MM2 CONTROL VALVES CLOSED LOOP PROPORTIONAL PRESSURE CONTROLS THE FUTURE OF CONTROL TM

MM1/MM2 CONTROL VALVES CLOSED LOOP PROPORTIONAL PRESSURE CONTROLS THE FUTURE OF CONTROL TM THE FUTURE OF CONTROL TM MM1/MM CONTROL VALVES CLOSED LOOP PROPORTIONAL PRESSURE CONTROLS 317-335-60 P.O. Box 18 McCordsville, Indiana 46055 www.proportionair.com FEATURES Universal Mounting Din Rail,

More information

THE FUTURE OF CONTROLTM MM1/MM2 CONTROL VALVES CLOSED LOOP PROPORTIONAL PRESSURE CONTROLS

THE FUTURE OF CONTROLTM MM1/MM2 CONTROL VALVES CLOSED LOOP PROPORTIONAL PRESSURE CONTROLS THE FUTURE OF CONTROLTM MM1/MM CONTROL VALVES CLOSED LOOP PROPORTIONAL PRESSURE CONTROLS 317-335-60 P.O. Box 18 McCordsville, Indiana 46055 www.proportionair.com FEATURES Universal Mounting Din Rail, Panel

More information

Conductivity Transmitter

Conductivity Transmitter Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants

More information

Proportional pressure controller

Proportional pressure controller Proportional pressure controller Introduction I. Introducing : Proportional Pressure Controller Input signal I or E Output pressure The MAC Proportional Pressure Controller, (PPC) is an innovative product

More information

Proportional pressure controller. Pressure range PSI/BAR. D Differential pressure G Gage pressure X X X - X X. Cover options

Proportional pressure controller. Pressure range PSI/BAR. D Differential pressure G Gage pressure X X X - X X. Cover options Proportional pressure controller Series PPC9A Port size Flow (Max) (Cv/Nl/min) Individual mounting Series 1/ /4 OPERATIONAL BENEFITS 6./600 covered analog base mount 1. Reliable operation, using two MAC

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree of protection

More information

FRnet Remote I/O Modules

FRnet Remote I/O Modules FRnet Remote I/O Modules.1. Overview P-1-1.2. Selection Guide P-2-1.2.1. Analog Input Module - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P-2-1.2.2. Analog Output

More information

Correction Reissue. Product Discontinuation Notices

Correction Reissue. Product Discontinuation Notices PRODUCT NEWS Correction Reissue Product Discontinuation Notices January 6, 2014 Pressure Sensors No. 2011265E(2) Discontinuation Notice of Pressure Sensor (Stainless diaphragm) E8AA series (Special product),

More information

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits RHE11 Hazardous Area Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mount Built in safety barriers allow operation with RHM sensor in hazardous area Selectable Metric and English

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Non-contact conveyance is possible.

Non-contact conveyance is possible. Cyclone Pad Non-contact conveyance is possible. Supply port Nozzle Workpiece with uneven and/or viscous surface Solar battery cell Whirlwind flow Air layer Electrode line Reflection prevention (viscous)

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Proportional pressure controller

Proportional pressure controller Proportional pressure controller Introduction I. Introducing : Proportional Pressure Controller Input signal I or E Output pressure The MAC Proportional Pressure Controller, (PPC) is an innovative product

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

INSTALLATION & MAINTENANCE INSTRUCTIONS

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION INSTALLATION & MAINTENANCE INSTRUCTIONS The GX series control valve is an electronic pressure regulator designed to precisely control the pressure of gaseous media proportional

More information

Cylindrical type proximity sensor

Cylindrical type proximity sensor Cylindrical type Cylindrical type proximity Features Improved the noise resistance with dedicated IC Built-in reverse polarity protection circuit (DC 3-wire type) Built-in surge protection circuit Built-in

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

DP2500 DP0100 DP0250 Differential Pressure Transmitter

DP2500 DP0100 DP0250 Differential Pressure Transmitter PB_DPT_03 2010 DP2500 DP0100 DP0250 Differential Pressure Transmitter The DP Low Differential Pressure Transmitter series is an accurate and cost competitive solution for measuring low pressures of air

More information

Introduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter

Introduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter Field Intelligent Device Series Electromagnetic Flowmeter Converter LF620,LF622 Introduction Combined with a multi-functional converter LF620 (combined type) or LF622 (separate type) equipped with its

More information

2/2 way Proportional Valve (motordriven)

2/2 way Proportional Valve (motordriven) 2/2 way Proportional (motordriven) Actuator isolated from fl ow path Excellent range and fast response times Low power consumption Orifi ce sizes 8 to 25 mm Versions: Standard, positioner, process controller

More information

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5) Electronic pressure measurement OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5) WIKA data sheet PE 81.65 Applications Hydraulics and pneumatics Pumps and compressors

More information

How to Order Manifold. Option. (1) DIN rail length specified B. (2) (3) Back pressure check valve (4)

How to Order Manifold. Option. (1) DIN rail length specified B. (2) (3) Back pressure check valve (4) Plug-in Unit Series SQ000 [Option] SSQ 0 0 Note) stations Note) The maximum number of stations depends on the type of electrical entries. Manifold mounting D DIN rail mounting style Note) E Direct mounting

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter.   TEMPERATURE. Technology Solutions Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof

More information

Electronically controlled proportional pressure regulating valves

Electronically controlled proportional pressure regulating valves Overview Description airfit control Electronically valve G1/4, G3/8, Type SRE-.. airfit control Electronically valve G3/8, G1/2, Type CRE-.. airfit control Electronically valve G3/4, G1, Type A25RE-..

More information

Multi-point Temperature Controller

Multi-point Temperature Controller Multi-point Temperature Controller Controls Up to Eight Zones, Built-in DeviceNet Communications Applications include plastic injection and extrusion machines, and continuous temperature control processes

More information

SS2 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

SS2 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments Smart Valve Positioner SS2 Linear / Rotary Smart performance with innovative and ever-strong coil drive even under harsh working environments Easy and quick auto-calibration Detecting RA (reverse acting)

More information

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5) Pressure OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5) WIKA data sheet PE 81.65 for further approvals see page 11 Applications Hydraulics and pneumatics Pumps and compressors

More information

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span 2-way motor valve Actuator isolated from flow path Excellent range and fast response times Low power consumption Orifice sizes 1 to 10 mm Versions: Standard, positioner, process controller and high pressure

More information

Model Sono-Trak Transit Time

Model Sono-Trak Transit Time Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic

More information

A new approach to static electricity countermeasures

A new approach to static electricity countermeasures Advanced intelligent Sensors NEW ELECTROSTATIC SENSOR EF-SSERIES A new approach to static electricity countermeasures Measurement of surface potentials while a production line is running Phone: 8.894.42

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution P R o D u c T I n F o R m at I o n TDR Level Sensor The clean solution Level sensors The clean solution Product description The is a hygienic level sensor for liquids using TDR technology a process for

More information

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING Technical leaflet 2 RD.5G.H4.02 Danfoss A/S (IC-MC/mr), 09-2004 Introduction AKS 32 and AKS 33 are pressure transmitters that

More information

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation Pressure Transmitter ATM.ECO - Analog Pressure Transmitter with Temperature Compensation CUSTOMER BENEFITS Entry level series into precision pressure measurement High measurement accuracy is ensured by

More information

Pressure Transmitter SIL

Pressure Transmitter SIL Pressure Transmitter SI Characteristics - TRANSDUCER - Pressure: Range: Output: Accuracy: Temperature of medium: Material enclosure: Pressure connection: Electrical connection: Protection: relative / absolute

More information

Electronic Pressure Switch Type MEP

Electronic Pressure Switch Type MEP MAKING MODERN LIVING POSSIBLE Data sheet Electronic Pressure Switch Type MEP MEP 2200 and MEP 2250 versions: Dual output Output : Switch output Hysteresis % FS Time constant ms Output 2: Analogue output

More information

Pressure transmitter AKS 32 and AKS 33

Pressure transmitter AKS 32 and AKS 33 Data sheet Pressure transmitter AKS 32 and AKS 33 AKS 32 and AKS 33 are pressure transmitters that measure a pressure and convert the measured value to a standard signal: y 1 5 V DC or 0 10 V DC for AKS

More information

Proportional pressure controller

Proportional pressure controller Proportional pressure controller Introduction I. Introducing : Proportional Pressure Controller Input signal I or E Output pressure The MAC Proportional Pressure Controller, (PPC) is an innovative product

More information

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters

Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters Data Sheet Brooks Industrial Brooks Digital Series Digital MFC's and MFM's Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters General Features:

More information

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y RA 9 /6.98 -Way Proportional Logic Cartridge Valve Model FE.. (Series X and X) Size 6... 6... 6 PSI (5 bar)... 75 GPM (8 L/min) RA 9 /6.98 Replaces: 5.9 Characteristics: Single land throttle valve (main

More information

Fuzzy Temperature Controllers E5AF

Fuzzy Temperature Controllers E5AF Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate

More information

SM32 SHOWN WITH 92 SERIES

SM32 SHOWN WITH 92 SERIES SM32 SHOWN WITH 92 SERIES S M 3 2 REMOTE STACK INPUT/OUTPUT MODULES TETHERED INPUT/OUTPUT MODULES B E N E F I T S 1. Ability to interface with the MAConnect system 2. Ease of installation 3. Reduction

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

Select digital Control Units matching your network

Select digital Control Units matching your network Digital Refer to our website for product details. CCS Use a search engine. Search You can also use your smartphone or cell phone. Select digital matching your network Digital Compliant The supplied AC

More information

Series LC8. Positioning Driver/For AC Servomotor. Compliant actuators/series LJ1, Series LG1, Series LTF

Series LC8. Positioning Driver/For AC Servomotor. Compliant actuators/series LJ1, Series LG1, Series LTF Positioning Driver/For AC Servomotor Series LC Compliant actuators/series LJ, Series LG, Series LTF Ho to Order Master LC B H N M F 50 W 0 W 00 W Poer voltage 0 VAC/5 VAC 00 VAC/ VAC Command I/O N NPN

More information

Field Network SRT Series

Field Network SRT Series Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-600 032 Ph: +91 44 4353 8888 Fax: 044 4353 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com Field Network SRT Series

More information

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm Electronic pressure measurement Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm WIKA data sheet PE 86.05 Applications Process technology Machine building and plant

More information

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display, DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration

More information

CompoBus/D-type Digital Controller

CompoBus/D-type Digital Controller CompoBus/D-type Digital Controller Digital Controller for the CompoBus/D and Conforming the DeviceNet Conforms the DeviceNet and connects a Programmable Controller without any programming. High performance

More information

USER S MANUAL. EX-20 Series. Amplifier Built-in Ultra-compact Type Photoelectric Sensor

USER S MANUAL. EX-20 Series. Amplifier Built-in Ultra-compact Type Photoelectric Sensor Amplifier Built-in Ultra-compact Type Photoelectric Sensor EX-20 Series USER S MANUAL WUME-EX20-3 Contens 1. Cautions 3 2. Part Description 4 3. Mounting 6 3-1 Mounting the sensor 6 3-2 Mounting to sensor

More information

DP2500 DP0100 DP0250 Differential Pressure Transmitter

DP2500 DP0100 DP0250 Differential Pressure Transmitter PB_DP_03 2011 DP2500 DP0100 DP0250 Differential Pressure Transmitter The DP Low Differential Pressure Transmitter series is an accurate and cost competitive solution for measuring low pressures of air

More information

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions

More information

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter for general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter for general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Machine tools Measurement and control technology

More information

Product Discontinuation Notices

Product Discontinuation Notices PRODUCT NEWS Product Discontinuation Notices August 1, 2011 Ultrasonic Sensors No. 2011264E Discontinuation Notice of Ultrasonic Sensor E4A special specification model, E4B special specification model,

More information

Signet 9950 Dual Channel Transmitter

Signet 9950 Dual Channel Transmitter Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for (Gen 2a) or later in Simplified Chinese,

More information

Target disk flowmeter for liquids and gases

Target disk flowmeter for liquids and gases Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

3- and 4-Wire DC 18 mm Diameter Inductive Sensors

3- and 4-Wire DC 18 mm Diameter Inductive Sensors -Wire -Wire - Inductive Sensors 5 to 20 mm sensing ranges 18 mm threaded barrels target indication Cable Micro (M12) quick disconnect models 80-85 for 85-872 for Technical Specifications 18 mm SUPPLY VOLTAGE

More information

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance 1 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1 guide... P.11~ General precautions... P.19 PHOTO PHOTO MEASURE panasonic.net/id/pidsx/global

More information

Proportional pressure controller

Proportional pressure controller Introduction I. Introducing : Proportional Pressure Controller Input signal I or E Output pressure The MAC Proportional Pressure Controller, (PPC) is an innovative product which converts an electrical

More information

Online data sheet FFUS15-1N1IO FFU FLOW SENSORS

Online data sheet FFUS15-1N1IO FFU FLOW SENSORS Online data sheet FFUS15-1N1IO FFU A B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Measurement principle Medium Ordering information Other models and accessories

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding

More information

& Control. Pressure Measurement. 600 Series Selection Guide BARATRON ABSOLUTE CAPACITANCE MANOMETERS

& Control. Pressure Measurement. 600 Series Selection Guide BARATRON ABSOLUTE CAPACITANCE MANOMETERS & Control Pressure Measurement W W W. M K S I N S T. C O M 600 Series Selection Guide BARATRON ABSOLUTE CAPACITANCE MANOMETERS 600 Series Absolute Capacitance Manometers The MKS 600 Series Baratron Absolute

More information

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter for general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter for general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Machine tools Measurement and control technology

More information

Electronic temperature switch with display Model TSD-30

Electronic temperature switch with display Model TSD-30 Electrical temperature measurement Electronic temperature switch with display Model TSD-30 WIKA data sheet TE 67.03 Applications Machine tools Hydraulic power packs Coolant and lubrication systems Machine

More information

MTS AND MTS PR¼ 16 OUTPUT SEQUENTIAL TIMER PENTAIR CLEAN AIR SYSTEMS

MTS AND MTS PR¼ 16 OUTPUT SEQUENTIAL TIMER PENTAIR CLEAN AIR SYSTEMS MTS AND MTS PR¼ 16 OUTPUT PENTAIR CLEAN AIR SYSTEMS MTS DESCRIPTION The Model MTS sequencer has been designed to guarantee the control of diaphragm valves mounted on pulse-jet dust collector filters containing

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Digital batch controller

Digital batch controller INSERTION Digital batch controller Type 8025 can be combined with... Compact or remote version for DN06 to DN400, PN10 Dosing On site calibration by Teach-In Check of input/output signals Total and daily

More information

Refer to manual. Failure to read message could result in personal injury or serious damage to the equipment or both.

Refer to manual. Failure to read message could result in personal injury or serious damage to the equipment or both. CERAVAC Transmitter CTR 100 N Short form manual 300544675_002_C0 Part numbers: 230 300V02 230 310V02 230 301V02 230 311V02 230 302V02 230 312V02 230 303V02 230 313V02 230 304V02 230 314V02 230 305V02 230

More information

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors. SilverMax Datasheet NEMA 23 Servomotors QuickSilver Controls, Inc. www.quicksilvercontrols.com SilverMax Datasheet - NEMA 23 Servomotors 23 Frame Sizes: 23-3, 23-5, 23H-1, 23H-3, 23H-5 / Series: E, E3,

More information

SCHMIDT Flow Sensor SS SS FB

SCHMIDT Flow Sensor SS SS FB Product description Flow sensor with integrated microcontroller transducer for the measurement of air-flow velocity and for the determination of the flow rate and flow volume. The aerodynamically styled

More information

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions... Flow meter Content F2-UN Description... 3 Technical data... 4 Dimension drawings... Operation... 8 Mounting instructions... 9 Order code... 10 F1-FP Description... 11 Technical Data... 12 Dimension drawings...

More information

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information with Linear Output or Manual Setting Detects Changes in Machine ON/OFF output can be set and checked quickly and easily from the vibration level meter. waveforms can be checked using the AC monitor output.

More information

PAD - Heavy Duty Differential Pressure Trasmitter

PAD - Heavy Duty Differential Pressure Trasmitter Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:

More information

Spring Return DuraDrive Proportional Actuator

Spring Return DuraDrive Proportional Actuator MS40-7043, MS4-7073, MS4-753 Spring Return DuraDrive Proportional Actuator For spring return applications that require proportional modulation control of dampers and valves in HVAC systems. Features: Proportional

More information

VP60. 5/3 Way proportional directional control valves Nominal diameter 8 direct operated sliding valves with µp-driven position control

VP60. 5/3 Way proportional directional control valves Nominal diameter 8 direct operated sliding valves with µp-driven position control / Way proportional directional control valves Nominal diameter 8 direct operated sliding valves with µp-driven position control Adjusted, linear flow characteristic Zero-overlap-characteristic High flow

More information

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance 13 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F- Glossary of terms... P.139 Sensor selection guide... P.9~ General precautions... P.1 PHOTO PHOTO

More information

SLAMf Series. Data Sheet. Elastomer Sealed, Digital, Thermal Mass Flow Meters and Controllers. Overview. Product Description.

SLAMf Series. Data Sheet. Elastomer Sealed, Digital, Thermal Mass Flow Meters and Controllers. Overview. Product Description. DS-TMF-SLAMf-Series-RevB-MFC-eng August, 2017 Data Sheet SLAMf Series Model SLAMf Thermal Mass Flow Elastomer Sealed, Digital, Thermal Mass Flow Meters and Controllers Overview The SLA Series mass flow

More information

44.5 mm mm. Long-range Models. 2 m. 5-pin Mini QD. Q45UBB63DAQ6 20, 40, 160 or 640 ms Q45UBB63DAC Yes. 5-pin Euro QD.

44.5 mm mm. Long-range Models. 2 m. 5-pin Mini QD. Q45UBB63DAQ6 20, 40, 160 or 640 ms Q45UBB63DAC Yes. 5-pin Euro QD. SENSORS ACCESSORIES LIGHT GAUGING ULTRASONIC MEASURING ARRAYS RADAR U-GAGE QU Flexible Ultrasonic Push-button TEACH programming makes it easy to set the near/far limits of the sensing window. Available

More information

Signet 2750 DryLoc ph/orp Sensor Electronics

Signet 2750 DryLoc ph/orp Sensor Electronics Signet 2750 DryLoc ph/ Sensor Electronics Features In-line integral mount and submersible installation versions Automatic temperature compensation Auto configuration for ph or operation In-line 2750 Submersible

More information

Positioner with HART Communication Type 3780

Positioner with HART Communication Type 3780 Positioner with HART Communication Type 780 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Supplied with an electric input signal from to 20 ma Travels

More information

Signet 2751 DryLoc ph/orp Smart Sensor Electronics

Signet 2751 DryLoc ph/orp Smart Sensor Electronics Signet 2751 DryLoc ph/ Smart Sensor Electronics Features Probe health monitoring, glass impedance and broken glass detection Memory chip interface that allows for transferable calibration, runtime data,

More information

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer. 99 PHOTO PHOTO LED Beam Sensor - SERIES Related Information General terms and conditions... P.1 Sensor selection guide...p.11~ / P.~ CA... P.79 ~ General precautions... P.7 Conforming to EMC Directive

More information

I-SERIES. A Wide Variety of Application Modes for Easy, High-Accuracy Measurements. Multi-Purpose CCD Laser Micrometre. IG Series LASER EDGE SENSOR

I-SERIES. A Wide Variety of Application Modes for Easy, High-Accuracy Measurements. Multi-Purpose CCD Laser Micrometre. IG Series LASER EDGE SENSOR Multi-Purpose CCD Laser Micrometre IG Series A Wide Variety of Application Modes for Easy, High-Accuracy Measurements LASER EDGE SENSOR Intelligent sensor I-SERIES Low-cost High Performance Thrubeam Digital

More information

How to Order Manifold. Manifold mounting. DIN rail mounting style Direct mounting style

How to Order Manifold. Manifold mounting. DIN rail mounting style Direct mounting style Plug Lead Unit Series 000 [Option] How to Order Manifold S 0 FD D Electrical entry F kit D-sub connector kit P kit Kit type Flat ribbon cable connector kit J kit Flat ribbon cable (0P) (PC Wiring System

More information