Electronic Vacuum Regulator. Standard Specifications. Model Voltage

Size: px
Start display at page:

Download "Electronic Vacuum Regulator. Standard Specifications. Model Voltage"

Transcription

1 Electronic Vacuum Regulator Series ITV9/9 Stepless control of vacuum in proportion to an electric signal Straight type Piping/Wiring Diagram (VDC, madc) Vacuum pump, Ejector ITV9 Right angle type Tank Set (Vacuum) Standard Specifications Model Voltage Current consumption Minimum supply vacuum () Maximum supply vacuum Regulating range Input impedance Output signal () (Monitor output) Current type () Voltage type Current type Voltage type Analog output Switch output Linearity Hysteresis Repeatability Sensitivity Temperature characteristics Accuracy Output display Units Ambient and fluid temperature Enclosure Weight ITV9 ITV9 4 VDC ±% to 5 VDC voltage 4 VDC type:. A or less voltage to 5 VDC type:.8 A or less Set. kpa kpa. to 8 kpa 4 to ma, to ma to 5 VDC, to VDC 4 points 5 Ω or less Approximately 6.5 kω Approximately. kω to 5 VDC (Load impedance: kω or more) 4 to ma (Sink type) (Load impedance: 5 Ω or less) NPN open collector output: Max. V, ma PNP open collector output: Max. ma Within ±% (Full span) Within.5% (Full span) Within ±.5% (Full span) Within.% (Full span) Within ±.% (Full span)/ C ±% (Full span) kpa (4) Minimum display: to 5 C (With no condensation) IP65 equivalent 5 g Note ) The minimum supply vacuum should be. kpa less than the maximum vacuum setting value. Note ) 4 to ma is not possible with the -wire type. voltage (4 VDC or to 5 VDC) is required. Note ) Either analog output or switch output must be selected. Furthermore, when switch output is selected, either NPN output or PNP output must also be selected. Use caution that the preset input type is not equipped with an output signal function. Note 4) Please contact SMC regarding indication with other units of. voltage 4 4 VDC to 5 VDC Current type 4 to madc Current type to madc Voltage type to 5 VDC Voltage type to VDC How to Order ITV 9 S 5 Pressure range 9. to 8 kpa 4 Monitor output None (For preset input) Analog output to 5 VDC Switch output/npn output Switch output/pnp output Analog output 4 to madc Thread type Nil N T F Rc NPT NPTF Pressure display unit 5 kpa Cable connector type Port size /4 S L N Option (Bracket) Nil B C Straight type m Right angle type m Without cable connector Without bracket 4-8-

2 Working Principle q Vacuum r Diaphragm (Vacuum pump, etc.) ATM (Atmospheric ) Series ITV9 Pressure display i Control circuit Output signal w Atmospheric Atmospheric u Pressure sensor e Pilot chamber t Vacuum valve. (Set ) y Atmospheric valve Working Principle When the input signal increases, the vacuum solenoid valve q turns, and the atmospheric w turns. Because of this, and the pilot chamber e are connected, the in the pilot chamber e becomes negative and acts on the top of the diaphragm. As a result, the vacuum valve t which is linked to the diaphragm r opens, and are connected, and the set becomes negative. This negative feeds back to the control circuit i via the sensor u. Then, a correct operation works until a vacuum proportional to the input signal is reached, and a vacuum is obtained which is always proportional to the input signal. Input signal + t Control circuit Block Diagram q Vacuum w Atmospheric u Pressure sensor. r Diaphragm Pilot valve Set F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA Linearity Hysteresis Repeatability. VE VY Output (kpa) Return Out.5.5 PPA AL (% F.S.) Pressure Characteristics. Set point side (Supply ) (kpa) (% F.S.) Flow Set : kpa Characteristics Supply : kpa Flow characteristics measurement conditions Set (kpa) Flow rate (l /min(anr)) Count Exhaust flow rate of the vacuum pump used for measurement: 5 l/min (ANR) Inlet vacuum : kpa (When outlet flow rate is l/min (ANR)) Maximum flow rate: l/min (ANR) (With inlet vacuum at 9 kpa) 4-8-

3 Dimensions ITV9 Note) Do not attempt to rotate the cable connector, as it does not turn. Cable connector (4-wire) Right angle type Cable connector (4-wire) Straight type 5 4-ø Mounting hole SMC E PREULATOR SMC E PREULATOR RESET SET 4 5 ITV9 ITV9 UNLOCK LOCK 84.5 M x Cable connection thread (99) () 9 ATM (Atmospheric ) SMC E PREULATOR ITV9 (Set ) Rc /4 port (Vacuum ).6 6 P4 (Option) 4-M5 x.8 thread depth 6 mm through Mounting hole -Rc /4 ATM port, port 5 9 R () () 6 INI (Option) -Rc /4 ATM port, port

4 Accessory (Option)/Part No. Description Cable Straight type connector Right angle type Caution Part no. P4 INI TM-4DSXH4 TM-4DLXH4 Dimensions 4 - ø ø 84. Connect the vacuum pump to the port, which is labeled.. Pressure adjustment changes from atmospheric to vacuum when the input signal is increased, and from vacuum to atmospheric when the input signal is decreased.. When adjusting the vacuum, be careful not to block the atmospheric inlet port labeled ATM. 4. Since this product is designed exclusively for use with negative, be careful not to apply positive in error. 5. In cases where the vacuum pump being used has a relatively small capacity, or the piping has a small inside diameter, etc., large variations in the set (the range of variation when changing from no flow to flow state) may appear. In this situation, the vacuum pump or the piping, etc. should be changed. In cases where it is not practical to change the vacuum pump, install a capacity tank (volume depending on the operating conditions) on the side. 6. The vacuum response time after a change in the input signal is influenced by the internal volume on the setting side (including piping). Since the capacity of the vacuum pump also influences the response time, give careful consideration to these points before operation.. If the electric power is shut off when in a control state, the on the setting side will go into a holding condition. However, this setting side will be held only temporarily and is not guaranteed. In addition, when atmospheric is desired, shut off the power after reducing the set, and then introduce atmospheric by using a vacuum release valve, etc. 8. If the power for this product is cut off by a power failure, etc. when it is in a controlled state, the setting side will be held temporarily. Further, if operated without sealing the setting side so that atmospheric air is sucked in, handle with care as air will continue to be sucked in Precautions Be sure to read before handling. Refer to pages 4-- to 4--4 for Safety Instructions and Common Precautions. Handling 5 5 () () R ø If the side to this product is interrupted while the power is still on, the internal will continue to operate and may cause a humming noise. Since this may shorten the life of the product, be sure to shut off the power when the side is shut off.. The setting side cannot be completely released from this product in the range below. kpa. In cases where the needs to be reduced completely to kpa, install a port valve, etc. on the setting side to discharge the residual.. This product is adjusted for each specification at the factory before shipment. Avoid careless disassembly or removal of parts, as this can cause failure.. The optional cable connector is a 4-wire type. When the monitor output (analog output, switch output) is not being used, keep it from touching the other wires, as this can cause malfunction.. Use caution that the right angle cable does not rotate and is limited to only one entry direction. 4. Take the following steps to avoid malfunction due to noise. ) Eliminate power supply noise during operation by installing a line filter, etc. in the AC power line. ) Install this product so that it will not be effected by noise, keeping the product and its wiring away from strong electric field sources such as motors and power lines. ) Make sure to take protective measures against load surge for an induction load (s, relays, etc.). 5. Refer to the instruction manual included with the product for details on its handling.. F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY PPA AL 4-8-

5 Caution Connect the cable to the connector on the body with the wiring arranged as shown below. Proceed carefully, as incorrect wiring can cause damage. Further, use DC power with sufficient capacity and a low ripple. Note) : () : () 4: () : () Precautions Be sure to read before handling. Refer to pages 4-- to 4--4 for Safety Instructions and Common Precautions. Wiring Monitor output wiring diagram Analog output: Voltage type Monitor output voltage Body RESET Current Signal Type Voltage Signal Type 4 ND (COMM) Monitor output Preset Input Type 4 ND (COMM) Note) A right angle type cable is also available. The entry direction for the right angle type connector is to the left (SUP port side). Never rotate it, since it's not designed to turn. Switch output: NPN type Load Wiring diagram Current signal type A Voltage signal type Vin Switch output: PNP type Load : 4 VDC to 5 VDC A : 4 to madc tomadc type S S : 4 VDC to 5 VDC Vin: to 5 VDC to VDC Analog output: Current type Monitor output current : 4 VDC to 5 VDC One of the preset s P through P4 is selected by the / combination of S and S. S S Preset P P P P4 For safety reasons, it is recommended that one of the preset s be set to MPa. When madc or more is applied, detecting device for overcurrent starts activating and then emits an error signal. (Error number 5 ) 4-8-4

Electronic Vacuum Regulator. How to Order ITV S 5. Monitor output

Electronic Vacuum Regulator. How to Order ITV S 5. Monitor output Electronic Vacuum Regulator Series ITV29/29 How to Order [Option] RoHS ITV 29 2 S 5 Pressure range 9.3 to 8 kpa Power supply voltage 24 VDC to 5 VDC Note) Communication models are available only for 24

More information

Series 10-ZSE30A(F)/10-ISE30A

Series 10-ZSE30A(F)/10-ISE30A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High-Precision Digital Pressure Switch Clean series For positive For vacuum/ compound Rated range ISEA 0.1 to 1 MPa How to Order 10 ISEA 01 N M 01 N01 C4H

More information

Series 10-ZSE80/10-ISE80

Series 10-ZSE80/10-ISE80 Series 0-ZSE80/0-ISE80 RoHS -Color Display Digital Pressure Switch For General Fluids Directional Control Valves For positive 0 80 For vacuum/ compound 80 80F N P B R T S V Rated range Symbol -X50 Clean

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree of protection

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

MM1/MM2 CONTROL VALVES CLOSED LOOP PROPORTIONAL PRESSURE CONTROLS THE FUTURE OF CONTROL TM

MM1/MM2 CONTROL VALVES CLOSED LOOP PROPORTIONAL PRESSURE CONTROLS THE FUTURE OF CONTROL TM THE FUTURE OF CONTROL TM MM1/MM CONTROL VALVES CLOSED LOOP PROPORTIONAL PRESSURE CONTROLS 317-335-60 P.O. Box 18 McCordsville, Indiana 46055 www.proportionair.com FEATURES Universal Mounting Din Rail,

More information

Valve Island with Electronic I/O

Valve Island with Electronic I/O Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

THE FUTURE OF CONTROLTM MM1/MM2 CONTROL VALVES CLOSED LOOP PROPORTIONAL PRESSURE CONTROLS

THE FUTURE OF CONTROLTM MM1/MM2 CONTROL VALVES CLOSED LOOP PROPORTIONAL PRESSURE CONTROLS THE FUTURE OF CONTROLTM MM1/MM CONTROL VALVES CLOSED LOOP PROPORTIONAL PRESSURE CONTROLS 317-335-60 P.O. Box 18 McCordsville, Indiana 46055 www.proportionair.com FEATURES Universal Mounting Din Rail, Panel

More information

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation Pressure Transmitter ATM.ECO - Analog Pressure Transmitter with Temperature Compensation CUSTOMER BENEFITS Entry level series into precision pressure measurement High measurement accuracy is ensured by

More information

Proportional pressure controller. Pressure range PSI/BAR. D Differential pressure G Gage pressure X X X - X X. Cover options

Proportional pressure controller. Pressure range PSI/BAR. D Differential pressure G Gage pressure X X X - X X. Cover options Proportional pressure controller Series PPC9A Port size Flow (Max) (Cv/Nl/min) Individual mounting Series 1/ /4 OPERATIONAL BENEFITS 6./600 covered analog base mount 1. Reliable operation, using two MAC

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

Optimising controls Vacuum switches

Optimising controls Vacuum switches Vacuum switches, pneumatic Converts a vacuum level to a pneumatic signal. Vacuum-actuated membrane linked to a pneumatic switch. Available preset or with adjustable vacuum level. Unit Value Feed pressure,

More information

Correction Reissue. Product Discontinuation Notices

Correction Reissue. Product Discontinuation Notices PRODUCT NEWS Correction Reissue Product Discontinuation Notices January 6, 2014 Pressure Sensors No. 2011265E(2) Discontinuation Notice of Pressure Sensor (Stainless diaphragm) E8AA series (Special product),

More information

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance 1 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1 guide... P.11~ General precautions... P.19 PHOTO PHOTO MEASURE panasonic.net/id/pidsx/global

More information

USER S MANUAL. EX-20 Series. Amplifier Built-in Ultra-compact Type Photoelectric Sensor

USER S MANUAL. EX-20 Series. Amplifier Built-in Ultra-compact Type Photoelectric Sensor Amplifier Built-in Ultra-compact Type Photoelectric Sensor EX-20 Series USER S MANUAL WUME-EX20-3 Contens 1. Cautions 3 2. Part Description 4 3. Mounting 6 3-1 Mounting the sensor 6 3-2 Mounting to sensor

More information

Base Mounted Plug-in Unit

Base Mounted Plug-in Unit For details about certified products conforming to international standards, visit us at www.smcworld.com. 000 Plug-in Unit SI unit COM N V V C C C6 M CM 6 B B B6 B M 000 Manifold model Plug-in unit Stations

More information

Proportional pressure controller

Proportional pressure controller Proportional pressure controller Introduction I. Introducing : Proportional Pressure Controller Input signal I or E Output pressure The MAC Proportional Pressure Controller, (PPC) is an innovative product

More information

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance 13 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F- Glossary of terms... P.139 Sensor selection guide... P.9~ General precautions... P.1 PHOTO PHOTO

More information

Conductivity Transmitter

Conductivity Transmitter Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

0.01kV (0 to ±0.99 kv)

0.01kV (0 to ±0.99 kv) Handheld Electrostatic Meter Series IZH10 Easy-to-use handheld electrostatic meter Rated charge amount range: ±20.0 kv Minimum display unit: 0.1kV (±1.0 to ±20.0 kv) Check the current situation before

More information

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions... Flow meter Content F2-UN Description... 3 Technical data... 4 Dimension drawings... Operation... 8 Mounting instructions... 9 Order code... 10 F1-FP Description... 11 Technical Data... 12 Dimension drawings...

More information

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING Technical leaflet 2 RD.5G.H4.02 Danfoss A/S (IC-MC/mr), 09-2004 Introduction AKS 32 and AKS 33 are pressure transmitters that

More information

INSTALLATION & MAINTENANCE INSTRUCTIONS

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION INSTALLATION & MAINTENANCE INSTRUCTIONS The GX series control valve is an electronic pressure regulator designed to precisely control the pressure of gaseous media proportional

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display, DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration

More information

FEATURES. 15 m ft. 4 m ft. 2 m ft. 100 mm in. 600 mm in. 15 m ft. 4 m ft. 2 m ft. 100 mm 3.

FEATURES. 15 m ft. 4 m ft. 2 m ft. 100 mm in. 600 mm in. 15 m ft. 4 m ft. 2 m ft. 100 mm 3. 273 Cylindrical Photoelectric Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1549~ guide... P.231~ General precautions... P.1552~ PHOTO PHOTO MEASURE -LS200

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Magnetic Inductive Flow Sensor induq

Magnetic Inductive Flow Sensor induq Operating manual (Translation) Operating manual... page 1-16 Magnetic Inductive Flow Sensor induq Series VMZ SIKA Ba_VMZ_en 10/2014. Please keep this operating manual for future reference. If the device

More information

USER S MANUAL. EX-30 Series. Amplifier Built-in Type Threaded Miniature Photoelectric Sensor

USER S MANUAL. EX-30 Series. Amplifier Built-in Type Threaded Miniature Photoelectric Sensor Amplifier Built-in Type Threaded Miniature Photoelectric Sensor EX-30 Series USER S MANUAL WUME-EX30-3 Contents 1. Cautions 3 2. Part Description 4 3. Mounting 5 3-1 Mounting the sensor 5 3-2 Installation

More information

FMG90 Series Electromagnetic Flow Meter

FMG90 Series Electromagnetic Flow Meter . FMG90 Series Electromagnetic Flow Meter - 2 - Series FMG90 Series FMG90 Table of contents page 0 About this operating manual... 4 1 Device description... 5 1.1 Delivery, unpacking and accessories...

More information

Online data sheet FFUS15-1N1IO FFU FLOW SENSORS

Online data sheet FFUS15-1N1IO FFU FLOW SENSORS Online data sheet FFUS15-1N1IO FFU A B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Measurement principle Medium Ordering information Other models and accessories

More information

Proportional pressure controller

Proportional pressure controller Proportional pressure controller Introduction I. Introducing : Proportional Pressure Controller Input signal I or E Output pressure The MAC Proportional Pressure Controller, (PPC) is an innovative product

More information

Laser Photoelectric Sensor

Laser Photoelectric Sensor Sensing Supply voltage Output Laser beam Laser beam 12-24 VDC ±10% 2 m, 10 m 20 to 50 m 80 ma Laser Photoelectric Sensor Prewired DC Sensor Provides Long-Distance Sensing of Objects as Small as 0.1 mm

More information

Most Suitable for a Variety of High-precision Displacement Measurements. Regular Reflective Sensors. Line Beam Sensors.

Most Suitable for a Variety of High-precision Displacement Measurements. Regular Reflective Sensors. Line Beam Sensors. / Length (2D CMOS Laser Type) Advanced Functions Integrated into a Compact Sensor for Easy Handling of High-grade Applications A Controller the size of a business card combined with the smallest Sensor

More information

Proportional pressure controller

Proportional pressure controller Proportional pressure controller Introduction I. Introducing : Proportional Pressure Controller Input signal I or E Output pressure The MAC Proportional Pressure Controller, (PPC) is an innovative product

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763)

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763) A Sensor Designed with the Customer Applications in Mind! High Accuracy The PS400 and PS500 provide an accuracy rating of ±0.5 percent of the full scale. Flexible Mounting Options Multiple threaded connections

More information

Installation and Connection Manual

Installation and Connection Manual Installation and Connection Manual (E Controller) Kawasaki Heavy Industries, Ltd. 90202-1003DEA PREFACE This manual explains the installation and connection procedures for Kawasaki Painting Robot. Read

More information

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information with Linear Output or Manual Setting Detects Changes in Machine ON/OFF output can be set and checked quickly and easily from the vibration level meter. waveforms can be checked using the AC monitor output.

More information

QL55 Series Luminescence Sensor

QL55 Series Luminescence Sensor Self-contained, microprocessor-based luminescence sensor Features Self-contained design in a robust, compact metal housing High sensitivity Microprocessor-controlled Senses luminescent marks, even on luminescent

More information

Pressure transmitter AKS 32 and AKS 33

Pressure transmitter AKS 32 and AKS 33 Data sheet Pressure transmitter AKS 32 and AKS 33 AKS 32 and AKS 33 are pressure transmitters that measure a pressure and convert the measured value to a standard signal: y 1 5 V DC or 0 10 V DC for AKS

More information

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ). ISO-14001 ISO-9001 SPECIFICATION SHEET CP SERIES 2-WIRE TYPE DO TRANSMITTER Models: DCP-20T FEATURES Rigid aluminium enclosure with free angle mounting. Simple operation offers free range setting, auto-calibration,

More information

HG-C SERIES. Micro Laser Distance Sensor. Reliable detection in 10 μm precision. We offer three types of laser sensor heads for various applications

HG-C SERIES. Micro Laser Distance Sensor. Reliable detection in 10 μm precision. We offer three types of laser sensor heads for various applications 215 PHOTO PHOTO LIGHT CURTAINS / USE Micro Laser Distance Sensor SERIES Related Information General terms and conditions... F-7 Glossary of terms / General precautions.. P.1455~ / P.1458~ Sensor selection

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y RA 9 /6.98 -Way Proportional Logic Cartridge Valve Model FE.. (Series X and X) Size 6... 6... 6 PSI (5 bar)... 75 GPM (8 L/min) RA 9 /6.98 Replaces: 5.9 Characteristics: Single land throttle valve (main

More information

2/2 way Proportional Valve (motordriven)

2/2 way Proportional Valve (motordriven) 2/2 way Proportional (motordriven) Actuator isolated from fl ow path Excellent range and fast response times Low power consumption Orifi ce sizes 8 to 25 mm Versions: Standard, positioner, process controller

More information

E3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features

E3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features bottle sensor Ideal for detecting transparent glass and plastic containers Features Stable operation even if container interval is shortened for higher productivity. Stable detection of 5 mm gaps that

More information

FMG70B Series Magnetic Inductive Flow Sensor

FMG70B Series Magnetic Inductive Flow Sensor . FMG70B Series Magnetic Inductive Flow Sensor - 2 - M-5575/0416 Table of contents page 0 About this operating manual...4 1 Device description...5 1.1 Delivery, unpacking and accessories...5 1.2 Intended

More information

Electronically controlled proportional pressure regulating valves

Electronically controlled proportional pressure regulating valves Overview Description airfit control Electronically valve G1/4, G3/8, Type SRE-.. airfit control Electronically valve G3/8, G1/2, Type CRE-.. airfit control Electronically valve G3/4, G1, Type A25RE-..

More information

Electronic Pressure Switch Type MEP

Electronic Pressure Switch Type MEP MAKING MODERN LIVING POSSIBLE Data sheet Electronic Pressure Switch Type MEP MEP 2200 and MEP 2250 versions: Dual output Output : Switch output Hysteresis % FS Time constant ms Output 2: Analogue output

More information

Z4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information.

Z4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information. / Length Micro Sensor LED-type Micro Sensor with Many Features in a Compact Body Compact body only /4th the volume of our previous product. % cost reduction over our previous product. High performance

More information

Pressure Transmitter SIL

Pressure Transmitter SIL Pressure Transmitter SI Characteristics - TRANSDUCER - Pressure: Range: Output: Accuracy: Temperature of medium: Material enclosure: Pressure connection: Electrical connection: Protection: relative / absolute

More information

Fuzzy Temperature Controllers E5AF

Fuzzy Temperature Controllers E5AF Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate

More information

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer. 99 PHOTO PHOTO LED Beam Sensor - SERIES Related Information General terms and conditions... P.1 Sensor selection guide...p.11~ / P.~ CA... P.79 ~ General precautions... P.7 Conforming to EMC Directive

More information

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems WLL 0(T) Photoelectric switches Photoelectric switches with fibre-optic cable Proximity mode Photoelectric switches with fibre-optic cable Through-beam mode Photoelectric switches WLL 0(T), fibre-optic

More information

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information *09005137* BA_EN_DE50 Rev.A 11/12 *09005137* d e v e l o p i n g s o l u t i o n s DE50 Operating Manual Differential pressure transmitter Table of Contents 1 Safety guidelines 2 Application purpose 3

More information

Ultrasonic Displacement Sensor E4DA

Ultrasonic Displacement Sensor E4DA Sensing Supply voltage Output Ultrasonic beam Ultrasonic Displacement Sensor Sensor s Narrow Ultrasonic Beam Accurately Detects Small Objects, Provides Linear Analog Output For Inspection, Measurement

More information

WLL 170 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC. Dimensional drawing R1.6 2-R

WLL 170 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC. Dimensional drawing R1.6 2-R WLL 0 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC 0... 0 mm Through-beam systems Dimensional drawing R. -R. Scanning distance 0... 0 mm. Proximity systems

More information

CompoBus/D-type Digital Controller

CompoBus/D-type Digital Controller CompoBus/D-type Digital Controller Digital Controller for the CompoBus/D and Conforming the DeviceNet Conforms the DeviceNet and connects a Programmable Controller without any programming. High performance

More information

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5) Electronic pressure measurement OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5) WIKA data sheet PE 81.65 Applications Hydraulics and pneumatics Pumps and compressors

More information

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span 2-way motor valve Actuator isolated from flow path Excellent range and fast response times Low power consumption Orifice sizes 1 to 10 mm Versions: Standard, positioner, process controller and high pressure

More information

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module / - ; 0 PSI Advantages / Benefits Wireless easy mounting and dismounting of sensor head by a Turn & Lock technique 3-wire Hall version to interface directly with PLC's (both NPN and PNP) Easy to connect:

More information

Digital Amplifier Ultrasonic Sensor E4C-UDA Series

Digital Amplifier Ultrasonic Sensor E4C-UDA Series Digital Amplifier Ultrasonic Sensor E4C-UDA Series A Reflective Sensor That Handles All Types of Sensing Object Colors and Patterns Sensor Heads Head Variations 300-mm Model E4C-DS30 Sensing Distance:

More information

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer. 99 PHOTO PHOTO LED Beam Sensor - SERIES Related Information General terms and conditions... P.1 Sensor selection guide...p.11~ / P.~ CA... P.79 ~ General precautions... P.7 Conforming to EMC Directive

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

SS2 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

SS2 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments Smart Valve Positioner SS2 Linear / Rotary Smart performance with innovative and ever-strong coil drive even under harsh working environments Easy and quick auto-calibration Detecting RA (reverse acting)

More information

40 mm Beam Pitch General Purpose Area Sensor NA40 SERIES

40 mm Beam Pitch General Purpose Area Sensor NA40 SERIES 9 0 mm Beam Pitch General Purpose Area Sensor SERIES Related Information General terms and conditions... F- Glossary of terms / General precautions...p.59~ / P.55~ guide... P.9~ Korea s S-mark... P.60

More information

Laser Photoelectric Sensor

Laser Photoelectric Sensor Laser Photoelectric Sensor Prewired DC Sensor Provides Long- Distance Sensing of Objects as Small as 0.1 mm Detect small objects over longer sensing distances with highly accurate positioning Attachable

More information

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE: Unit 1 / 14 Biscayne Way Jandakot WA 6104 P.O. Box 3232, Success WA 6964 Tel: (08) 9414 7666 Fax: (08) 9414 7677 Email: dg@dginstruments.com.au Website: www.dginstruments.com.au A.B.N: 59 113 005 959 DATE:

More information

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range GT3A Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEDs UL,

More information

How to Order Manifold. Manifold mounting. DIN rail mounting style Direct mounting style

How to Order Manifold. Manifold mounting. DIN rail mounting style Direct mounting style Plug Lead Unit Series 000 [Option] How to Order Manifold S 0 FD D Electrical entry F kit D-sub connector kit P kit Kit type Flat ribbon cable connector kit J kit Flat ribbon cable (0P) (PC Wiring System

More information

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm. Series Digital LCD Timer DIN W48 H48mm Features Power supply : 4-4VAC 5/6Hz, 4-4VDC universal Easy to switch Up/Down mode programmable output modes and timing ranges () Selectable function by front digital

More information

KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB

KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 Manual-NEO_5003-4_1-17

More information

Proportional pressure controller

Proportional pressure controller Introduction I. Introducing : Proportional Pressure Controller Input signal I or E Output pressure The MAC Proportional Pressure Controller, (PPC) is an innovative product which converts an electrical

More information

Ionizer. IZS40/41/42 Series. Potential amplitude: 25 V or less Rapid neutralization of static electricity: Fastest time: 0.

Ionizer. IZS40/41/42 Series. Potential amplitude: 25 V or less Rapid neutralization of static electricity: Fastest time: 0. Ionizer // Series Note ) Potential amplitude: V or less Rapid neutralization of static electricity: Fastest time:. seconds Note ) RoHS Dual AC type Series Potential amplitude of the workpiece is reduced

More information

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5) Pressure OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5) WIKA data sheet PE 81.65 for further approvals see page 11 Applications Hydraulics and pneumatics Pumps and compressors

More information

XPC10 High temperature miniature pressure sensor

XPC10 High temperature miniature pressure sensor Absolute, sealed and gauge ranges 10 to 500 bar [150 to 7 500 psi] High temp. operation from -40 up to 220 ºC [-40 to 428 F] Stainless steel construction Amplified output available For static and dynamic

More information

SERVO VALVES. Maximum Flow. Maximum Operating Pressure MPa (PSI) U.S.GPM Page. Graphic Symbols.

SERVO VALVES. Maximum Flow. Maximum Operating Pressure MPa (PSI) U.S.GPM Page. Graphic Symbols. I SERVO VALVES Valve Graphic Symbols Maximum Operating Pressure MPa (PSI) Maximum Flow U.S.GPM.5 1 2 5 50 0 0 500 1 2 3 5 30 50 0 0 300 500 00 00 L/min Page Direct High Speed Linear Servo Valves LSVG-03

More information

Absolute Rotary Encoder

Absolute Rotary Encoder Absolute Rotary Encoder Use the Tough (Rated IP64 for Degree of Protection) Combined with a PLC or Cam Positioner for Optimum Control and Ease-of-Use Incorporates a sealed bearing, meeting IP64 for durability

More information

FLOWPET-EG. Description 1 Accumulated total flow (8-digit) 2 Instantaneous flowrate, L/h (mode:b1) and L/min (mode:b2) Selectable with

FLOWPET-EG. Description 1 Accumulated total flow (8-digit) 2 Instantaneous flowrate, L/h (mode:b1) and L/min (mode:b2) Selectable with GENERAL SPECIFICATION FLOWPET-EG MODEL LS 7 6 7-4 GS.No.GBB323-1-E GENERAL FLOWPET-EG is an OVAL flowmeter primarily intended for use in boiler feed water and fuel oil metering applications. Field proven

More information

37 mm x Width 30 mm. Rapid neutralization of static electricity: Fastest time 0.1 S. Dual AC Type IZT42 Series

37 mm x Width 30 mm. Rapid neutralization of static electricity: Fastest time 0.1 S. Dual AC Type IZT42 Series Separate Controller Bar Type Ionizer Space saving Height Potential amplitude: 25 V or less *1 37 mm x Width 3 mm Rapid neutralization of static electricity: Fastest time.1 S *2 37 mm 3 mm High-voltage

More information

Series LC8. Positioning Driver/For AC Servomotor. Compliant actuators/series LJ1, Series LG1, Series LTF

Series LC8. Positioning Driver/For AC Servomotor. Compliant actuators/series LJ1, Series LG1, Series LTF Positioning Driver/For AC Servomotor Series LC Compliant actuators/series LJ, Series LG, Series LTF Ho to Order Master LC B H N M F 50 W 0 W 00 W Poer voltage 0 VAC/5 VAC 00 VAC/ VAC Command I/O N NPN

More information

SERVICE INSTRUCTIONS Model 9670 Lubricant Pump

SERVICE INSTRUCTIONS Model 9670 Lubricant Pump TM TM SERVICE INSTRUCTIONS Model 9670 Lubricant Pump 9670 DESCRIPTION Model 9670 Lubricant Pump is designed to pump light to heavy oils directly from the original container. This design features a 10:1

More information

NA1-PK3 SERIES. Compact Size Picking Sensor. Boasts a compact, pocket lighter size enabling universal installation

NA1-PK3 SERIES. Compact Size Picking Sensor. Boasts a compact, pocket lighter size enabling universal installation 44 PHOTO PHOTO Compact Size Sensor NA-PK SERIES Related Information General terms and conditions... F- Glossary of terms... P.549~ guide... P.49~ General precautions...p.55~ Recognition Make sure to use

More information

Digital batch controller

Digital batch controller INSERTION Digital batch controller Type 8025 can be combined with... Compact or remote version for DN06 to DN400, PN10 Dosing On site calibration by Teach-In Check of input/output signals Total and daily

More information

Indicator (4digit) (5digit) 8-pin plug counter

Indicator (4digit) (5digit) 8-pin plug counter 8 Pin Plug type DIN W8 H8mm 8 Pin plug counter Features Upgraded counting speed : 1cps / cps / 2kcps / 5kcps Decimal point setting(fixed decimal point of display) Wide range of power : 1-2VAC 5/6Hz 12-2VAC

More information

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter for general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter for general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Machine tools Measurement and control technology

More information

Non-contact conveyance is possible.

Non-contact conveyance is possible. Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (8) 26-8 www.cmafh.com Cyclone Pad Non-contact conveyance is possible. Workpiece with uneven and/or viscous surface

More information

Solid-state Timer H3DS

Solid-state Timer H3DS Solid-state Timer H3DS DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to 230 VAC/VDC

More information

Triple Beam Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

Triple Beam Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global 337 Triple Beam Adjustable Range Reflective Photoelectric SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1549~ guide... P.231~ General precautions... P.1552~ PHOTO

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

Though the size is compact, the measurement display uses 4 digit, 8 mm in letter height, red 7-segment LEDs. Letter height 8mm (0.

Though the size is compact, the measurement display uses 4 digit, 8 mm in letter height, red 7-segment LEDs. Letter height 8mm (0. SERIES Ultra-compact Digital Panel Controller CA Convenient s packed in a small body! Ultra-compact Large display Flexible scaling Conforming to EMC Directive Ultra-compact size of W 48 H 24 D 65.5 mm

More information

Magnetic Inductive Flow Sensor

Magnetic Inductive Flow Sensor Operating manual (Translation) Operating manual... page 1-20 Magnetic Inductive Flow Sensor Series VMZ Types VMZ 030 VMZ 081 VMZ 082 VMZ 153 VMZ 204 VMZ 205 VMZ 256 SIKA Ba_VMZ_en 11/2017. Please keep

More information