How to Order Manifold. Manifold mounting. DIN rail mounting style Direct mounting style

Size: px
Start display at page:

Download "How to Order Manifold. Manifold mounting. DIN rail mounting style Direct mounting style"

Transcription

1 Plug Lead Unit Series 000 [Option] How to Order Manifold S 0 FD D Electrical entry F kit D-sub connector kit P kit Kit type Flat ribbon cable connector kit J kit Flat ribbon cable (0P) (PC Wiring System compatible) C kit 0 Note) P ( 0P ) FD0 FD FD FD PD0 PD PD PD PDC JD0 Stations station stations Note) The maximum number of stations depends on the type of electrical entries. D E Note) Lead wire connector location () Manifold mounting DIN rail mounting style Direct mounting style Note) Type E is only available with a C kit. Refer to page 0 for details. Cable specifications D-sub connector (P) kit, without cable D-sub connector (P) kit, with. m cable D-sub connector (P) kit, with.0 m cable D-sub connector (P) kit, with.0 m cable Flat ribbon cable (P) kit, without cable Flat ribbon cable (P) kit, with. m cable Flat ribbon cable (P) kit, with.0 m cable Flat ribbon cable (P) kit, with.0 m cable Flat ribbon cable (0P) kit, without cable Flat ribbon cable (0P) PC Wiring System compatible CE compliant Nil Q CE marked (P), (R) port size Nil (P), (R) port, One-touch fittings for ø0 00T (P), (R) port, One-touch fittings for ø/" Option Nil None 0 to () DIN rail length specified B Back pressure check valve K () Special wiring specifications (Except double wiring) N With name plate (Side ported only) R External pilot specifications S Built-in silencer, direct exhaust Note ) Specify DIN rail length with D at the end. (Enter the number of stations inside.) The number of stations that may be displayed is longer than the manifold number of stations. Example: -D0 Note ) When installing back pressure check valves only on the stations required, enter the part number and specify the mounting stations on a manifold specification sheet. Note ) Standard wiring specifications are for double wiring. Indicate wiring specifications for single wiring or mixed single and double wiring, or when exceeding the standard maximum number of stations. (Except C kit.) Note ) For specifying two or more options, enter them alphabetically. Example: -BKN Refer to pages 0 to 0 for manifold option parts. Stations to stations to stations to stations to stations Max. number of stations for special wiring specifications stations stations stations () Max. number of solenoids C Connector kit to stations Connector kit 0 Note ) Separately order the 0P type cable assembly for the P kit. Note ) The maximum number of stations should not be more than the maximum number of solenoids. (The number of solenoids are counted as: for single solenoids and for type P and P double solenoids.) Refer to page 0 for manifold spare parts.

2 Type of actuation position single () B C 0 position closed center ()(B) position exhaust center ()(B) position double (Latching) () ()(B) (R)(P)(R) (R) (P)(R) position double (Double solenoid) () ()(B) ()(B) (R) (P)(R) position pressure center ()(B) position dual port valve (R) N.C. () (B) (R) (P)(R) (R) (P)(R) (R) (P)(R) (R) (P)(R) () (P) (B) ()(B) (R) (P)(R) (R) (R) N.C. (P) N.C. position dual port valve () () (B) (R) (R) N.O. (P) N.O. position dual port valve () () (B) (R) N.O. Note ) Refer to page 0 for precautions. Note ) For double solenoid specifications, the function symbol below is D. Note ) Only rubber seal types are applicable. Seal 0 Function Nil Standard type (.0 W DC) position double (Double solenoid specifications) D (Latching type: Nil) N Negative COM Y () () Low wattage type (0. W DC) () R External pilot specifications Note ) Except double (latching) type. Note ) Please select when you expect to energize the unit for extended periods of time. Refer to page for details. Note ) Except dual port valves. Note ) When two or more symbols are specified, indicate them alphabetically. How to Order Valves L C Manual override Nil Non-locking push type (Tool required) Coil voltage VDC VDC When ordering with manifolds When only valves are required. Note) Except double (latching) type. Note) Light/Surge voltage suppressor is built-in. Port plug mounting port Nil None Port () B Port (B) Cylinder port C One-touch fitting for ø C One-touch fitting for ø C One-touch fitting for ø L One-touch fitting for ø L One-touch fitting for ø L One-touch fitting for ø B Note) Locking type (Tool required) Electrical entry L Plug connector type With 00 mm lead wire With/Without manifold block Nil M MB Without manifold block CE compliant Nil Q CE marked With manifold block Lead wire is not included. Lead wire is not included. For adding stations Side ported () Top ported Note ) Can be changed to side ported configuration. Note ) Refer to page 0 for the inch-size one-touch fittings. D Note) Slide locking type (Manual type) Only side ported type applicable LO Plug connector type without connector With manifold block, built-in back pressure check valve For F, P, J kit manifolds Note) Note) Indicate LO when ordering centralized wiring type manifolds, F, P, and J kits, since the lead wire will be attached to the manifold side. 0 J VP C Z

3 R P R P Series 000 Manifold Option Blanking plate S P. 0 Individual SUP/EXH spacer P. 0 Name plate (-N) P. 0 External pilot P. 0 C S000-PR-- S000-N-n specifications (-R) L External pilot port SUP/EXH block P. 0 SUP block plate P. 0 S000-PR--C0 (-S) S000-B-R Blanking plug KQP-0/0/0/0 P. 0 Dual flow fitting C0 S000--N P. 0 Individual SUP spacer C S000-P-- L P. 0 EXH block plate S000-B-R P. 0 Port plug VZ000-CP P. 0 Silencer (For EXH port) P. 0 SMC N00 Individual EXH spacer C S000-R-- L P. 0 Back pressure check valve (-B) P. 0 Built-in silencer (-S) P. 0 Special wiring specifications (-K) P. 00 S000-BP D-sub connector Terminal no. 0 0 station stations stations stations stations stations stations stations SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) Connector terminal no. lthough the standard products come with double wiring, mixed single and double wiring is available upon request. 0

4 How to Order Manifold ssembly (Example) Example: D-sub connector kit, with cable ( m) position single ( VDC) 0-L0-C ( sets) position double (Double solenoid) ( VDC) 0D-L0-C ( sets) position exhaust center ( VDC) 0-L0-C ( set) Blanking plate S ( set) m D-sub connector cable XT00-DS-00 Stations F kit (D-sub connector kit) 0-L0-C 0-L0-C 0-L0-C S-0FD-D set (F kit -station manifold base) 0-L0-C sets ( position single) 0D-L0-C sets ( position double [double solenoid]) 0-L0-C set ( position exhaust center) S set (Blanking plate) 0D-L0-C 0D-L0-C Cylinder port fitting C: ø One-touch fitting Manifold base ( stations) S-0FD-D The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. dd the valve and option part numbers in order starting from the first station on the. When entry of part numbers becomes complicated, indicate on the manifold specification sheet. S L0-C 0D-L0-C J VP C Z 0

5 Series 000 Valve Specifications Model Series 000 position position position position single () (B) (R) (P)(R) position double (Latching) ()(B) ()(B) (R) (P)(R) (R) (P)(R) position double (Double solenoid) () (B) () (B) (R) (P)(R) Number of solenoids Single Double (Latching) Double (Double solenoid) Closed center Exhaust center Pressure center Dual port valve JIS Symbol Flow characteristics () Model / (P /B) / / (/B R/R) C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv 0 0 0D D (R) (P)(R) B C. 0. Specifications 0.0. Valve construction Fluid Maximum operating pressure Single Double (Latching) Double (Double solenoid) position position mbient and fluid temperature Lubrication Pilot valve manual override Vibration/Impact resistance () Protection structure Coil rated voltage llowable voltage fluctuation Coil insulation type Power consumption VDC (Current) VDC Response time (ms) () Standard: Low W wattage 0 or less or less or less or less or less or less or less 0 or less 0 or less or less or less or less or less or less or less or less or less or less or less or less or less or less or less or less Note ) Values for the top ported cylinder port size of C, CYL Values of EXH. The side ported type will be about 0% less. Note ) Based on JIS B -. (Values with a supply pressure of 0. MPa and light/surge voltage suppressor. Values fluctuate depending on the pressure and air quality.) Valve specifications Solenoid specifications Min. operating pressure Mass (g) ir/inert gas 0. MPa 0. MPa 0. MPa 0. MPa 0. MPa 0. MPa 0. MPa 0. MPa 0. MPa 0. MPa 0 to 0 C () Not required Push type (Tool required)/locking type (Tool required) Slide locking type (Manual type) 0/0 m/s Dust tight VDC, VDC ±0% of rated voltage Equivalent to class B W DC ( m), 0. W DC ( m) () W DC ( m), 0. W DC ( m) () Note ) Use dry air to prevent condensation when operating at low temperatures. Note ) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and deenergized states every once for each condition. Note ) Values for the low wattage (0. W) specifications. position closed center ()(B) (R) (P)(R) position exhaust center ()(B) position pressure center ()(B) (R)(P)(R) position dual port valve () position dual port valve (B) N.O. N.O. position dual port valve (C) (R) (P)(R) N.C. N.C. N.C. N.O. 00

6 Manifold Specifications Base model Porting specifications Port size (), (B) (P), (R) Port location Port size pplicable solenoid valve Type of connection pplicable station () () () station station mass mass (g) (g) S- - C0 (For ø0) Option Built-in silencer, direct exhaust C (For ø) C (For ø) C (For ø) L (For ø) L (For ø) L (For ø) 0 F kit: D-sub connector to stations P to stations P kit: Flat ribbon cable 0P to stations J kit: Flat ribbon cable to stations PC Wiring System compatible C kit: Connector kit to stations Note ) One-touch fittings in inch sizes are also available. For details, refer to page 0. Note ) Can be changed to side ported configuration. Note ) n optional specification for special wiring is available to increase the maximum number of stations. Refer to page 00 for details. Note ) Except valves. For valve mass, refer to page00. P F kit Side () Top (), (B) port (R) port (P) port P/0P (P kit) 0P (J kit) P kit J kit J VP C Z C kit 0

7 Series 000 F Kit (D-sub Connector kit) Simplification and labor savings for wiring work can be achieved by using a D-sub connector for the electrical connection. Using connector for flat ribbon cable (P) conforming to MIL standard permits the use of connectors put on the market and gives a wide interchangeability. Top or side entry for the connector can be changed freely, allowing later changes according to the mounting space. Manifold specifications Series 000 Port location Side, Top Porting specifications Port size (P), (R) (), (B) C0 C, C, C Maximum number of stations stations ( as an option) D-sub Connector ( pins) XT00-DS D-sub connector cable assemblies can be ordered with manifolds. Refer to manifold ordering. L (.) D-sub Connector Cable ssembly Cable ssembly part no. length (L) Note. m m m 0 SMC.0 XT00-DS-0 XT00-DS-00 XT00-DS-00 Cable 0. mm x cores O.D. ø. ø0 Seal (length indication) Molded cover x M. x 0. Connector DB-SF-N manufactured by Japan viation Electronics Industry, Ltd. Socket side Terminal no. Cable 0. mm x cores Cable assembly D-sub Connector Cable ssembly Terminal No. Terminal number 0 0 Lead wire color Dot marking None Brown None Red None Orange None Yellow None Pink None Blue None Purple White Gray White White Red Yellow Red Orange Red Yellow Pink Blue White Purple None Gray None Orange Red White Brown White Pink Red Gray Red White White None For other commercial connectors, use a pins type with female connector conforming to MIL-C-0. Cannot be used for transfer wiring. Lengths other than the above are also available. Please contact SMC for details. Electric characteristics Item Characteristics Conductor resistance Ω/km, 0 C or less Withstand voltage VC, min. 000 Insulation resistance MΩ/km, 0 C or more 0 Note) The minimum bending radius for D- sub connector cables is 0 mm. Connector manufacturers example Fujitsu, Ltd. Japan viation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd. Hirose Electric Co., Ltd. stations Valves are numbered from the. Electrical wiring specifications D-sub connector 0 station stations stations stations stations stations stations stations stations 0 stations stations stations 0 s the standard electrical wiring specifications, double wiring (connected to SOL. and SOL. B) is adopted for the internal wiring of each station for stations or less, regardless of valve and option types. Mixed single and double wiring is available as an option. For details, refer to page 00. Connector terminal no. Lead wire colors for D-sub connector assembly XT00-DS Terminal no. Polarity Lead wire Dot color marking SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. 0 0 ( ) None ( ) Yellow ( ) Brown None ( ) Pink ( ) Red None ( ) Blue White ( ) Orange None ( ) Purple None ( ) Yellow None ( ) Gray None ( ) Pink None ( ) Orange ( ) Blue None ( ) Red White ( ) Purple White ( ) Brown White ( ) Gray ( ) Pink Red ( ) White ( ) Gray Red ( ) White Red ( ) White ( ) Yellow Red ( ) White None ( ) Orange Red Note) Positive common Negative common specifications specifications Note) When using the negative common specifications, use valves for negative common.

8 (Mounting hole dimension) (.).. pplicable connector: D-sub connector (P) (Conforming to MIL-C-0) L. L L M: External pilot port.. P =. Release for switching 0 connector direction ( position). [Single, Double, Dual port valve]. () EXH outlet C0: (R) port C0: (P) port Stations n R P 0. P =. For top ported B. Indicator light Manual override x M clamp screw J VP C Z n x C, C, C ((), (B) port) C: One-touch fitting for ø C: One-touch fitting for ø C: One-touch fitting for ø Dimensions L L L L n Formula: L =.n + 0 n: Stations (Maximum stations)

9 Series 000 P Kit (Flat ribbon cable connector) Simplification and labor savings for wiring work can be achieved by using a MIL type for the electrical connection. Using connector for flat ribbon cable (P, 0P) conforming to MIL standard permits the use of connectors put on the market and gives a wide interchangeability. Top or side entry for the connector can be changed freely, allowing later changes according to the mounting space. Flat Ribbon Cable ( pins, 0 pins) Manifold Specifications Series 000 Port location Porting specifications Port size (P), (R) (), (B) Side, Top C0 C, C, C Maximum number of stations stations ( as an option) 0 XT00-FC - Type P flat ribbon cable connector assemblies can be ordered with manifolds. Refer to manifold ordering. 0 (0P).(P) Flat Ribbon Cable Connector ssembly Cable ssembly part no. length (L). m m m Terminal no. (.) Red P XT00-FC- XT00-FC- XT00-FC- L Cable assembly WG 0P XT00-FC0- XT00-FC0- XT00-FC0- For other commercial connectors, use a pins or 0 pins with strain relief conforming to MIL-C-0. Cannot be used for transfer wiring. Lengths other than the above are also available. Please contact SMC for details. Connector manufacturers example Hirose Electric Co., Ltd. Sumitomo M Limited Fujitsu Limited Japan viation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd. Oki Electric Cable Co,. Ltd. stations Valves are numbered from the. Electrical wiring specifications Flat ribbon cable connector station stations stations stations stations stations stations stations stations 0 stations stations stations 0 0 <P> Connector terminal no. Terminal no. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. Double wiring (connected to SOL. and SOL. B) is adopted for the internal wiring of each station, regardless of valve and option types. Mixed single and double wiring is available as an option. For details, refer to page 00. Triangle mark indicator position Polarity station stations stations stations stations stations stations stations stations ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) 0 ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) 0 ( ) ( ) ( ) ( ) ( ) ( ) ( ) Note) Positive Negative common common specifications specifications <0P> Terminal no. Polarity SOL. ( ) ( ) SOL. ( ) ( ) SOL. ( ) ( ) SOL. ( ) ( ) SOL. ( ) 0 ( ) SOL. ( ) ( ) SOL. ( ) ( ) SOL. ( ) ( ) SOL. ( ) ( ) 0 Positive common specifications Note) Negative common specifications 0 Note) When using the negative common specifications, use valves for negative common.

10 (Mounting hole dimension) (.).. L. L M: External pilot port L. P =. Release for switching 0 connector direction ( position). [Single, Double, Dual port valve]. () Triangle mark indicator position pplicable connector: Flat ribbon cable connector (P) (Conforming to MIL-C-0). EXH outlet C0: (R) port C0: (P) port 0 R P. P =. For top ported B. Stations n Indicator light Manual override x M clamp screw..... n x C, C, C ((), (B) port) C: One-touch fitting for ø C: One-touch fitting for ø C: One-touch fitting for ø 0 J VP C Z Dimensions L L L L n Formula: L =.n + 0 n: Stations (Maximum stations)

11 Series 000 J Kit (PC wiring system compatible flat ribbon cable Kit) PC Wiring System compatible. Using connector for flat ribbon cable (0P) conforming to MIL standard permits the use of connectors put on the market and gives a wide interchangeability. Top or side entry for the connector can be changed freely, allowing later changes according to the mounting space. Manifold specifications Series 000 Port location Side, Top Porting specifications Port size (P), (R) (), (B) C0 C, C, C Maximum number of stations stations ( as an option) stations Valves are numbered from the. Electrical wiring specifications Double wiring (connected to SOL. and SOL. B) is adopted for the internal wiring of each station, regardless of valve and option types. Mixed single and double wiring is available as an option. For details, refer to page 00. Terminal no. Polarity SOL. 0 ( ) station ( ) Flat ribbon cable connector SOL. ( ) stations ( ) 0 SOL. ( ) stations 0 ( ) SOL. ( ) stations ( ) SOL. ( ) 0 stations ( ) Connector terminal no. SOL. ( ) stations ( ) Triangle mark SOL. ( ) indicator position stations ( ) SOL. ( ) stations ( ) ( ) ( ) ( ) ( ) Note) Positive Negative common common specifications specifications Note) When using the negative common specifications, use valves for negative common. For details about the PC Wiring System, refer to catalog CT.E0-0 separately. 0

12 .TURN.PUSH.TURN.PUSH (Mounting hole dimension) (.).. M: External pilot port Release for switching connector direction ( position). [Single, Double, Dual port valve] Triangle mark indicator position pplicable connector: Flat ribbon cable connector (0P) (Conforming to MIL-C-0) ().. EXH outlet C0: (R) port C0: (P) port. 0 Stations R P L L L P =. 0. P =. B B n For top ported B. Indicator light Manual override x M clamp screw n x C, C, C ((), (B) port) C: One-touch fitting for ø C: One-touch fitting for ø C: One-touch fitting for ø J VP C Z Dimensions L L L L n Formula: L =.n + 0 n: Stations (Maximum stations)

13 Series 000 C Kit (Connector) Standard with lead wires connected to each valve individually. Manifold Specifications Series 000 Port location Side, Top Porting specifications Port size (P), (R) (), (B) Maximum number of stations C0 C, C, C stations Wiring Specifications: Positive COM Specifications Since lead wires are connected to the valves as shown below, connect each wire to the power supply. stations Valves are numbered from the. Wiring Specifications: Negative COM Specifications (Option) Since lead wires are connected to the valves as shown below, connect each wire to the power supply. Single solenoid : side solenoid ( ) Single solenoid Red: side solenoid SOL. Lead wire color ( ) Red Red: COM SOL. Lead wire color Red ( ) : COM ( ) Double solenoid SOL. ( ) Lead wire color Red ( ) White Individual Common Connector ssembly Part No. Lead wire length Socket only ( pcs.) 00 mm 00 mm 000 mm 000 mm 000 mm : side solenoid ( ) White: B side solenoid ( ) Red: COM Single solenoid Double solenoid XT-L XT-L XT-L XT-L- XT-L- XT-L-0 XT-L-0 XT-L-0 XT-L-0 XT-L-0 XT-L-0 Plug connector lead wire length The lead wire length of the valves with lead wire is 00 mm. When ordering a lead wire length of 00 mm or longer, list the part numbers for the valve without connector and the connector assembly. Example) For lead wire length of 000 mm: 0-LO-C pcs. XT-L-0 pcs. Double solenoid SOL. Lead wire color Red ( ) White Red: side solenoid White: B side solenoid : COM ( ) Connector ssembly Part No. Lead wire length Single solenoid Double solenoid Socket only ( pcs.) XT-L 00 mm XT-NL XT-NL 00 mm XT-NL- XT-NL- 000 mm XT-NL-0 XT-NL mm XT-NL-0 XT-NL mm XT-NL-0 XT-NL-0 Note) When using the negative common specifications, use valves for negative common. Plug connector lead wire length The lead wire length of the valves with lead wire is 00 mm. When ordering a lead wire length of 00 mm or longer, list the part numbers for the valve without connector and the connector assembly. Example) For lead wire length of 000 mm: 0-LO-C pcs. XT-NL-0 pcs. ll Common Connector ssembly for ll Common Type Part No. Mounted valve (n: Station) Part no. Connector assembly shape Mounted valve (n: Station) Part no. Connector assembly shape Station n Single type XT-0B- Note) CB Red Station n Single type XT-0BN- Note) CB Red Station to (n ) station Single type XT-0- Note) CB Station to (n ) station Single type XT-0N- Note) CB Station n Latching, double solenoid -position, dual -port blanking plate Station to (n ) station Latching, double solenoid -position, dual -port blanking plate XT-B- Note) XT-- Note) Note) : Lead wire length. 0: 0. m, 0: 0. m, 0: m, 0: m, 0: m, 0: m 0 CB CB Red White White Station n Latching, double solenoid -position, dual -port blanking plate Station to (n ) station Latching, double solenoid -position, dual -port blanking plate XT-BN- Note) XT-N- Note) CB CB Red White White

14 (Mounting hole dimension) (.).. Lead wire length: 00 M: External pilot port ( position). [Single, Double, Dual port valve] L L L L P =...PUSH B.TURN.PUSH B.TURN B Indicator light Manual override x M clamp screw... J VP (). EXH outlet C0: (R) port C0: (P) port Stations n R P For top ported.. 0 C Z. 0. P =. n x C, C, C ((), (B) port) C: One-touch fitting for ø C: One-touch fitting for ø C: One-touch fitting for ø Dimensions L L L L L n Formula: L =.n +, L =.n + 0 n: Stations (Maximum stations)

15 Construction: Series 000 Plug Lead Type Main Parts and Pilot Valve ssembly type Single: 0 r e q w type Single: re q w 0 ()(B) ()(B) Double (Latching): 0 t e q w Double (Double solenoid): 0D y e q w e u position: 0 y e q w e u (R) (P)(R) 0 ()(B) (R)(P)(R) 0D ()(B) (R) (P)(R) ()(B) ()(B) ()(B) Double (Latching): t e q w Double (Double solenoid): D y e q w e u position: y e q w e u () (B) ()(B) (R) (P)(R) () (B) (R) (P)(R) D ()(B) (R)(P)(R) () (B) J VP C Z (R) (P)(R) Component Parts No. Description Body Spool/Sleeve Spool Piston (R)(P)(R) (R)(P)(R) Material Zinc die-casted Stainless steel () luminum () Resin (R)(P)(R) (R) (P)(R) Dual port valve: B C i e w q w e (R) (P)(R) Pilot Valve ssembly Note) No. For single Model For double (Latching) For double (Double solenoid) on side P: For side For double (Double solenoid) on B side P: For B side Dual port: For side Dual port: For B side Note) Nil : Standard N : Negative COM specifications Y : Low wattage specifications S(Y)- (N)J 0SL- J Negative COM: 0SN- J S(Y)- (N)J S(Y)- J S(Y)- (N)J-X S(Y)- J-X o B N.C. N.C. N.O. N.O. C N.C. N.O. 0

How to Order Manifold. Option. (1) DIN rail length specified B. (2) (3) Back pressure check valve (4)

How to Order Manifold. Option. (1) DIN rail length specified B. (2) (3) Back pressure check valve (4) Plug-in Unit Series SQ000 [Option] SSQ 0 0 Note) stations Note) The maximum number of stations depends on the type of electrical entries. Manifold mounting D DIN rail mounting style Note) E Direct mounting

More information

Base Mounted Plug-in Unit

Base Mounted Plug-in Unit For details about certified products conforming to international standards, visit us at www.smcworld.com. 000 Plug-in Unit SI unit COM N V V C C C6 M CM 6 B B B6 B M 000 Manifold model Plug-in unit Stations

More information

Series 10-ZSE80/10-ISE80

Series 10-ZSE80/10-ISE80 Series 0-ZSE80/0-ISE80 RoHS -Color Display Digital Pressure Switch For General Fluids Directional Control Valves For positive 0 80 For vacuum/ compound 80 80F N P B R T S V Rated range Symbol -X50 Clean

More information

Series 10-ZSE30A(F)/10-ISE30A

Series 10-ZSE30A(F)/10-ISE30A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High-Precision Digital Pressure Switch Clean series For positive For vacuum/ compound Rated range ISEA 0.1 to 1 MPa How to Order 10 ISEA 01 N M 01 N01 C4H

More information

Powerpole Connectors - PP75: up to 120 Amps

Powerpole Connectors - PP75: up to 120 Amps Powerpole Connectors - PP75: up to 120 Amps PP75 with Mounting Wings PP75 series Powerpole housings can be used for wire-to-wire, wire-to-board, and wire-to-busbar applications. Wire sizes from #16 AWG

More information

Serial Transmission Type (Integrated)

Serial Transmission Type (Integrated) TypeS Series SX000/000 Base Mounted Manifold Stacking Type IN Rail Mounted Serial Transmission Type (Integrated) How to Order Manifold SSX S A 0 U 0 Series SX000 SX000 Symbol Specifications O Without A

More information

SB 50 Connectors - up to 120 amps

SB 50 Connectors - up to 120 amps Connectors - up to 120 amps Based off the design pioneered by Anderson in 1953, APP s two pole SB connectors set the standard for DC power distribution and battery connections. connectors feature a one

More information

Powerpole Connectors - PP75: up to 120 Amps

Powerpole Connectors - PP75: up to 120 Amps Powerpole Connectors - PP75: up to 120 Amps PP75 with Mounting Wings PP75 series Powerpole housings can be used for wire-to-wire, wire-to-board, and wire-to-busbar applications. Wire sizes from #16 AWG

More information

Powerpole Connectors - PP75: up to 120 Amps

Powerpole Connectors - PP75: up to 120 Amps Powerpole Connectors - PP75: up to 120 Amps PP75 with Mounting Wings PP75 series Powerpole housings can be used for wire-to-wire, wire-to-board, and wire-to-busbar applications. Wire sizes from #16 AWG

More information

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0 Touch Switch Unique 18 mm Capacitive Touch Switch with Choice of Three Actuators is Activated with Only a Very Slight Physical Contact Lightweight objects, such as thin wire or foil can be accurately detected.

More information

WIRE-PRESS SOCKETS (AXW)

WIRE-PRESS SOCKETS (AXW) FOR PC BORD TO WIRE XW WIRE-PRESS SOCKETS (XW) FETURES 1. Pressure welding method for superior wiring and no need to strip wires. pplicable wires: WG #22, #24, #26, #28. 2. Two pressure weldings assure

More information

RG Connector (Molded Mating Extension Cable Required) A H B G. MS Connector (Mating Connector: P/N ; MS3116F-12-10S or Extension Cable)

RG Connector (Molded Mating Extension Cable Required) A H B G. MS Connector (Mating Connector: P/N ; MS3116F-12-10S or Extension Cable) T E M P O S O N I C S L S E R I E S INSTALLATION A N A L O G O U T P U T 550570 B W I R I N G - A N A L O G O U T P U T S RG Connector: (Voltage or Current Output) 1 Gray 0 to 10 Vdc, 4 to 20 ma, or 0

More information

6th digit. 5th digit. 4th digit. Code Specifications 3 20-bit absolute (standard) D 20-bit incremental (standard) Design Revision Order

6th digit. 5th digit. 4th digit. Code Specifications 3 20-bit absolute (standard) D 20-bit incremental (standard) Design Revision Order Rotary s Model Designations - 3 D Series st+nd digits 3rd digit th digit th digit th digit 7th digit st+nd digits Rated Output th digit Serial Encoder 7th digit Options Code 3 3 W W 9 8 W 3.3 kw.8 kw 3.9

More information

Information. A hard stop is not required for the clamping. Mounting conditions are reproducible when the cylinder is replaced.

Information. A hard stop is not required for the clamping. Mounting conditions are reproducible when the cylinder is replaced. Information SMC Corporation Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 11-21, JAPAN http://www.smcworld.com 213 SMC Corporation All Rights Reserved Slim-line Power Clamp Cylinder (Clamp arm

More information

FAS 10 mm PICOSOL Direct acting solenoid valve

FAS 10 mm PICOSOL Direct acting solenoid valve FS 0 mm PICOSOL > > /, /; Manifold mounting > > Long life 00 million cycles > > Compact Design > > Low power consumption Technical features Medium: ir, oxygen, neutral gases (0 %... 9 % humidity, non condensing),

More information

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8 to 1/2 NPT. Proportional Valves. Features. 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/8" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Control achieved by applying straight voltage between 0 and 24 VDC

More information

SBS Connectors - up to 110 amps

SBS Connectors - up to 110 amps SBS Connectors - up to 11 amps SBS 75G SBS 75X Wire to Wire The patented SBS connector family is designed to provide high power in a compact ergonomic housing with protection against accidental contact

More information

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications Latching Relay MMK CSM_MMK_DS_E_1_1 Mechanically Latching Relays Based on the MM Power Relay Low power consumption due to mechanical latch for economic operation. Relays with mixed coil specifications

More information

Directional valves Electrically operated Series 563, 565, 567. Brochure

Directional valves Electrically operated Series 563, 565, 567. Brochure Directional valves Electrically operated Brochure 2 Directional valves Electrically operated 3/2-directional valve, Series 563 Qn = 1350 l/min plate connection Electr. connection: Plug, Form B, industry

More information

Proportional pressure controller

Proportional pressure controller Proportional pressure controller Introduction I. Introducing : Proportional Pressure Controller Input signal I or E Output pressure The MAC Proportional Pressure Controller, (PPC) is an innovative product

More information

Coaxial Switch. Ordering Information. High-frequency, High-capacity Coaxial Switch Supporting Bandwidth to 26.5 GHz. Model Number Legend:

Coaxial Switch. Ordering Information. High-frequency, High-capacity Coaxial Switch Supporting Bandwidth to 26.5 GHz. Model Number Legend: Coaxial Switch High-frequency, High-capacity Coaxial Switch Supporting Bandwidth to 26.5 GHz Models supporting bandwidth of 26.5 GHz achieve superior high-frequency characteristics, such as an isolation

More information

XXXX e. X d.. X X X a

XXXX e. X d.. X X X a The Heavy uty incremental encoder type 0H boasts a high degree of ruggedness in a very compact design. Its special construction makes it perfect for all applications in very harsh environments. / RoHS

More information

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4 to 1/2 NPT. Proportional Valves. Features. 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

TWIN ROD CYLINDERS 6 CONTENTS

TWIN ROD CYLINDERS 6 CONTENTS CAD drawing data catalog is available. ACTUATORS GENERAL CATALOG TWIN ROD CYLINDERS6 CONTENTS TWIN ROD CYLINDERS 6 Features 745 Specifications/Order Codes 747 Inner Construction and Major Parts 748 Dimensions

More information

Rotary Measurement Technology Incremental Encoders

Rotary Measurement Technology Incremental Encoders -20 to 60 C Temperature Shock/vibration resistant Short-circuit protection Reverse polarity protection High rotational speed Rugged Balanced, stainless-steel clamping rings, special bearing-shaft connection

More information

MODEL: KS. Plug-in Signal Conditioners K-UNIT

MODEL: KS. Plug-in Signal Conditioners K-UNIT Plug-in Signal Conditioners K-UNIT DC ALARM Functions & Features Providing relay contact closures at preset DC input levels Dual (Hi/Lo) trip Multi-turn screwdriver setpoint adjustments Monitor jacks provided

More information

60 mm sq. (2.36 inch sq.)

60 mm sq. (2.36 inch sq.) 6 mm sq. (.36 inch sq.) 1.8 /step RoHS Unipolar winding, Connector type Unipolar winding, Dimensions for attaching NEMA3 are interchangeable (47.14 mm-pitch) Bipolar winding, Connector type p. 76 Bipolar

More information

SBS Connectors - up to 110 amps

SBS Connectors - up to 110 amps Connectors - up to 1 amps NEW 75G 75X Wire to Wire The patented connector family is designed to provide high power in a compact ergonomic housing with protection against accidental contact with live circuits.

More information

Electronic Vacuum Regulator. Standard Specifications. Model Voltage

Electronic Vacuum Regulator. Standard Specifications. Model Voltage Electronic Vacuum Regulator Series ITV9/9 Stepless control of vacuum in proportion to an electric signal Straight type Piping/Wiring Diagram (VDC, madc) Vacuum pump, Ejector ITV9 Right angle type Tank

More information

MODEL: AS4V. Plug-in Signal Conditioners M-UNIT

MODEL: AS4V. Plug-in Signal Conditioners M-UNIT Plug-in Signal Conditioners M-UNIT DC ALARM (dual or quad alarm trip; field-configurable) Functions & Features Provides relay outputs at preset DC input levels Quad or dual trip Setting and display in

More information

37 mm x Width 30 mm. Rapid neutralization of static electricity: Fastest time 0.1 S. Dual AC Type IZT42 Series

37 mm x Width 30 mm. Rapid neutralization of static electricity: Fastest time 0.1 S. Dual AC Type IZT42 Series Separate Controller Bar Type Ionizer Space saving Height Potential amplitude: 25 V or less *1 37 mm x Width 3 mm Rapid neutralization of static electricity: Fastest time.1 S *2 37 mm 3 mm High-voltage

More information

Electronically controlled proportional pressure regulating valves

Electronically controlled proportional pressure regulating valves Overview Description airfit control Electronically valve G1/4, G3/8, Type SRE-.. airfit control Electronically valve G3/8, G1/2, Type CRE-.. airfit control Electronically valve G3/4, G1, Type A25RE-..

More information

2.5mm Pitch Connectors for Full Lock and Discrete Wire Connection

2.5mm Pitch Connectors for Full Lock and Discrete Wire Connection .5mm Pitch Connectors for Full Lock and Discrete Wire Connection DF1E Series UL, C-UL Listed Full lock function added Inner-lock system full lock mechanism Features 1. Full Lock Function dded The inner

More information

Field Network SRT Series

Field Network SRT Series Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-600 032 Ph: +91 44 4353 8888 Fax: 044 4353 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com Field Network SRT Series

More information

Details on the New G2RS

Details on the New G2RS New G2RS Series The G2RS Space-saving Power Plug-in Relay has a mechanical indicator and nameplate as standard features. A relay with a lockable test button is also available. Details on the New G2RS Overview

More information

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet Temposonics Magnetostrictive Linear Position Sensors GB-M / GB-T SSI Sensor element and electronics can be changed Flat & compact sensor electronics housing Electrical connection is freely rotatable MEASURING

More information

Products catalogue (I-P Edition)

Products catalogue (I-P Edition) Products catalogue (I-P Edition) Products catalogue (I-P Edition) FROM QUALITY OUR NATURAL DEVELOPMENT Active in the industry of Refrigeration and Air Conditioning for fifty-five years, Castel is well-established

More information

Absolute Rotary Encoder

Absolute Rotary Encoder Absolute Rotary Encoder Use the Tough (Rated IP64 for Degree of Protection) Combined with a PLC or Cam Positioner for Optimum Control and Ease-of-Use Incorporates a sealed bearing, meeting IP64 for durability

More information

Series LC8. Positioning Driver/For AC Servomotor. Compliant actuators/series LJ1, Series LG1, Series LTF

Series LC8. Positioning Driver/For AC Servomotor. Compliant actuators/series LJ1, Series LG1, Series LTF Positioning Driver/For AC Servomotor Series LC Compliant actuators/series LJ, Series LG, Series LTF Ho to Order Master LC B H N M F 50 W 0 W 00 W Poer voltage 0 VAC/5 VAC 00 VAC/ VAC Command I/O N NPN

More information

VP60. 5/3 Way proportional directional control valves Nominal diameter 8 direct operated sliding valves with µp-driven position control

VP60. 5/3 Way proportional directional control valves Nominal diameter 8 direct operated sliding valves with µp-driven position control / Way proportional directional control valves Nominal diameter 8 direct operated sliding valves with µp-driven position control Adjusted, linear flow characteristic Zero-overlap-characteristic High flow

More information

400 (±2,5 V/ V/ ,3% V4A

400 (±2,5 V/ V/ ,3% V4A LVDT Inductive Position Transducer - Hydraulic Series Series Hydraulic position measurement in hydraulic cylinders of machine controls ranges 10...300 mm temperature -40...+150 C (sensors) 0...+60 C (external

More information

Valve Island with Electronic I/O

Valve Island with Electronic I/O Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication

More information

JARVIS. Model25CL-4,5,6 Hock Cutter and Loin Dropper. 25CL--5 Front Legs and Horns. 25CL--4 Hind Legs and Horns. 25CL--6 Loins

JARVIS. Model25CL-4,5,6 Hock Cutter and Loin Dropper. 25CL--5 Front Legs and Horns. 25CL--4 Hind Legs and Horns. 25CL--6 Loins Model25CL-4,5,6 Hock Cutter and Loin Dropper 25CL--4 Hind Legs and Horns 25CL--5 Front Legs and Horns 25CL--6 Loins EQUIPMENT SELECTION... Ordering No. TABLE OF CONTENTS... Page 25CL--4... 4025007 25CL--5...

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

Disc Gap Control DGC-2. Technical Manual

Disc Gap Control DGC-2. Technical Manual GB Disc Gap Control DGC-2 Technical Manual Contents Introduction Electronic unit... 1 Tracer valve... 1 Technical data... 2 Component layout... 4 Functions, electronic unit Stepper motor operation...

More information

ES Series Features Detecting distance twice that of conventional

ES Series Features Detecting distance twice that of conventional Long-distance Separate-amplifier Series Features Detecting distance twice that of conventional sensors Detecting distance easily adjustable Wide range of sensor head types available Built-in alarm output

More information

2.4mm coaxial connectors for frequency test measurements

2.4mm coaxial connectors for frequency test measurements 2.4mm coaxial connectors for frequency test measurements 2.4mm Series Functional diagram Straight plug H2.4-P-SS085 Plug side Attenuator PlugJack H2.4-AT (**)-PJ ** 0, 3, 6, 10, 20dB Features 1. Complies

More information

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure General-purpose Relays MK-S (New Models) CSM_MK-S_DS_E 1 New Super MK Relays. Latching Lever Added to the Series. Same mounting and internal wiring as the previous Super MK Relays Built-in mechanical indicator

More information

Proportional Directional Control Valves Size 6

Proportional Directional Control Valves Size 6 Proportional Directional Control Valves Size 6 Direct controlled, electrically adjustable Interface to DIN 2 30 and ISO 0 PN [p max. ] = 35 bar 750055.06.02.06 Description (standard units) Design The proportional

More information

Optimising controls Vacuum switches

Optimising controls Vacuum switches Vacuum switches, pneumatic Converts a vacuum level to a pneumatic signal. Vacuum-actuated membrane linked to a pneumatic switch. Available preset or with adjustable vacuum level. Unit Value Feed pressure,

More information

SGMJV. Rotary Servomotors SGMJV - 01 A D A 2 1. Model Designations. 2Without Gears. 1st+2nd digits. 3rd digit. 5th digit. 6th digit.

SGMJV. Rotary Servomotors SGMJV - 01 A D A 2 1. Model Designations. 2Without Gears. 1st+2nd digits. 3rd digit. 5th digit. 6th digit. Rotary s Designations 2Without s - D 2 Series st+2nd s rd 4th th th 7th st+2nd s Rated Output th Design Revision Order 7th Options Code W W C2 W 2 2 W 4 4 W W 8 7 W rd Power Supply Voltage Code th Code

More information

40 mm Beam Pitch General Purpose Area Sensor NA40 SERIES

40 mm Beam Pitch General Purpose Area Sensor NA40 SERIES 9 0 mm Beam Pitch General Purpose Area Sensor SERIES Related Information General terms and conditions... F- Glossary of terms / General precautions...p.59~ / P.55~ guide... P.9~ Korea s S-mark... P.60

More information

5th digit. 4th digit. 6th digit. Design Revision Order. Shaft End. Code Specifications

5th digit. 4th digit. 6th digit. Design Revision Order. Shaft End. Code Specifications Rotary s Designations 2Without Gears - 0 D 2 Series st+2nd digits 3rd digit 4th digit 5th digit 6th digit 7th digit st+2nd digits Rated Output 5th digit Design Revision Order 7th digit Options Code 5 50

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.8... 4 mm Port connection 1/8, 1/4 or sub-base Type 2873 can be combined with Type 8605 Digital

More information

Electric Actuator/ High Rigidity Slider Type

Electric Actuator/ High Rigidity Slider Type INFORMATION Electric Actuator/ High Rigidity Slider Type RoHS Clean Room Specification ISO Class 4 * (Class ) *2, *3! Built-in vacuum piping Possible to mount the main body without removing the external

More information

3RH1 contactor relays, 4- and 8-pole

3RH1 contactor relays, 4- and 8-pole Siemens AG 2010 RH, TH Contactor Relays RH1 contactor relays, 4- and 8-pole Overview AC and DC operation IEC 60947, EN 60947. The RH1 contactor relays are suitable for use in any climate. They are finger-safe

More information

Components for safety applications

Components for safety applications Metal, turret head, types CS-A, CS-C and CS-E Double insulated, turret head, types CS-PA, CS-TA and CS-TE Presentation Metal, types CS-A, CS-C, CS-E Switches with or without locking of the actuator Pages

More information

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y RA 9 /6.98 -Way Proportional Logic Cartridge Valve Model FE.. (Series X and X) Size 6... 6... 6 PSI (5 bar)... 75 GPM (8 L/min) RA 9 /6.98 Replaces: 5.9 Characteristics: Single land throttle valve (main

More information

THT TYPE. Interface unit with built-in DO module FEATURES

THT TYPE. Interface unit with built-in DO module FEATURES INTERFACE UNIT THT TYPE FEATURES Both and DO modules of the THT type interface unit have the same structure, providing a smart appearance. The connector sockets and operation indicators are located at

More information

Palm-sized, 16-channel Relay Terminals

Palm-sized, 16-channel Relay Terminals Palm-sized, -channel Relay Terminals RELAY TERMINAL FEATURES. Possible to select relay for use in the relay terminal in accordance with load. [Mountable relay: PA relay and Power PhotoMOS (voltage sensitive

More information

High Accuracy Positioning Sensors EG Series Features

High Accuracy Positioning Sensors EG Series Features High ccuracy Positioning s EG Series Features Ultra-small sensor head Non-contact, stable detection in wide temperature range Highly stable amplifier provides 1 µm. Mil repeatability Hi/Lo tolerance detection

More information

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm. Perfect data processing 0.

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm. Perfect data processing 0. R-Series Temposonics Absolute, Non-Contact Position Sensors R-Series Temposonics RP and RH 25 7600 mm Perfect data processing 0.5 μm Rugged industrial sensor Linear and absolute measurement LEDs for sensor

More information

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI General-purpose Relay CSM_GR-_-S_DS_E Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped

More information

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR General-purpose Relay MY New model Versatile and Function-filled Miniature Power Relay for Sequence Control and Power Switching Applications Models with lockable test buttons now available. Many variations

More information

Tools for other contacts Tools for FOC contacts Crimping machine TC-C Crimping machine TK-M

Tools for other contacts Tools for FOC contacts Crimping machine TC-C Crimping machine TK-M Contents Page for contacts Han D... 99.02 for contacts Han E... 99.04 for contacts Han-Yellock... 99.06 for contacts Han C... 99.09 for contacts D-Sub... 99.11 for other contacts... 99.12 for FOC contacts...

More information

New Servo Concept: Junma

New Servo Concept: Junma New Servo Concept: Junma Junma uses the world s premier servo technology to provide unmatched performance with a quick and efficient setup. This totally new plug and play design concept requires no parameter

More information

30 AMP POWER RELAY WITH SPACE SAVING DESIGN

30 AMP POWER RELAY WITH SPACE SAVING DESIGN VDE 3 AMP POWER RELAY WITH SPACE SAVING DESIGN JH-RELAYS 2..2 3.. FEATURES Many safety-oriented characteristics incorporated Contact gap: more than 3 mm. inch for Form A and 2 Form A Breakdown voltage

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

Engineering Data Single Reduction Parts List Item # Description Basic Single Reduction Unit 1. Gear Housing 2. Pipe Plug 3. Vent Plug 4. Splash Guard

Engineering Data Single Reduction Parts List Item # Description Basic Single Reduction Unit 1. Gear Housing 2. Pipe Plug 3. Vent Plug 4. Splash Guard Engineering Data Single Reduction Parts List Item # Description Basic Single Reduction Unit 1. Gear Housing 2. Pipe Plug 3. Vent Plug 4. Splash Guard 5. Input Cover 6. O-Ring 7. Hex Head Cap Screw 8. Input

More information

Proportional Directional Control Valves Nominal sizes 16 and 25

Proportional Directional Control Valves Nominal sizes 16 and 25 Proportional Directional Control Valves Nominal sizes 16 and 25 Pilot operated, electrically adjustable Interface acc. to DIN 24 340 and ISO 4401 PN [p max. ] = 315 bar 7502968.06.01.06 Description Design

More information

Heavy-duty Metal Body Safety Interlock Switch. DIN mounting pattern for globally recognized mounting configuration

Heavy-duty Metal Body Safety Interlock Switch. DIN mounting pattern for globally recognized mounting configuration C R US Conforms to EN1088, EN292, EN60947-5-1, EN60204-1, EN50041 UL and C-UL listed T4011 Heavy-duty Metal Body Safety Interlock Switch Rugged enclosure the all metal housing and stainless steel actuator

More information

RT-3 UNIT RELAY 4-POINT TERMINAL

RT-3 UNIT RELAY 4-POINT TERMINAL Slim, Space-saving, -point Unit Relay RT-3 UNIT RELAY -POINT TERMINAL [PA-N Relay type, PhotoMOS Power (Voltage sensitive type)] -point Terminal [PA-N relay, PhotoMOS Power (Voltage sensitive type)] Mountable

More information

B34 Series Regulator Commercial and Industrial Regulator

B34 Series Regulator Commercial and Industrial Regulator B34 Series Regulator Commercial and Industrial Regulator Appropriate for many commercial and industrial uses such as gas engines, burners, furnaces and boilers. The rapid response of the B34 is particularly

More information

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Type 4WRPEH RE 29035 Edition: 2017-04 Replaces: 2015-02 Size 6 Component series 2X Maximum

More information

Compact, Space-saving (61% reduction in volume compared to the SMC conventional products) 124.5

Compact, Space-saving (61% reduction in volume compared to the SMC conventional products) 124.5 Electric Slide Table Easy setting Data can be set with only items: position and speed. Data xis Step No. 0 Posn 0.00 mm Speed 00 mm/s Teaching box screen Compact, Space-saving (% reduction in volume compared

More information

Spring Return DuraDrive Proportional Actuator

Spring Return DuraDrive Proportional Actuator MS40-7043, MS4-7073, MS4-753 Spring Return DuraDrive Proportional Actuator For spring return applications that require proportional modulation control of dampers and valves in HVAC systems. Features: Proportional

More information

Electronic Vacuum Regulator. How to Order ITV S 5. Monitor output

Electronic Vacuum Regulator. How to Order ITV S 5. Monitor output Electronic Vacuum Regulator Series ITV29/29 How to Order [Option] RoHS ITV 29 2 S 5 Pressure range 9.3 to 8 kpa Power supply voltage 24 VDC to 5 VDC Note) Communication models are available only for 24

More information

Main Components. Pipe and Bolt Threading Machine 300/300A. Early Style. Printed in U.S.A. Ridge Tool Company/Elyria, Ohio, U.S.A.

Main Components. Pipe and Bolt Threading Machine 300/300A. Early Style. Printed in U.S.A. Ridge Tool Company/Elyria, Ohio, U.S.A. Pipe and Bolt Threading Machine 00/00A Main Components Early Style 0 0 * 0 0 0 For Information on Cutters, Die Heads and Reamers SEE INDEX Ref. 0 0 Catalog 0 00 00 0 0 0 00 0 0 0 0 0 0 0 00 0 00 00 00

More information

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples. Miniature High Capacity Relays with SPST-NO 0A and SPST-NO + SPST-NC A SPST-NO 0A and SPST-NO + SPST-NC A for power switching and output that satisfy the needs for space-saving. Small High-capacity Relays

More information

Small-sized, plastic type, push-pull lock connectors

Small-sized, plastic type, push-pull lock connectors Small-sized, plastic type, push-pull lock connectors RP17 Series Product Specifications Ratings Rated current Rated voltage Features 1. Superior mating operability Secure mating and easy unmating is achieved

More information

OptiLine 45 Floor boxes

OptiLine 45 Floor boxes OptiLine 45 Floor outlet boxes P89490 Type Colour Dimensions A/B/C (mm) Qty per pack Ref. No. Floor outlet box including mounting frames for Altira, trim frame with four quick-fix devices and lid with

More information

RoHS. High shaft load capacity. Shock / vibration resistant

RoHS. High shaft load capacity. Shock / vibration resistant Due to their sturdy bearing construction in Safety Lock Design, the Sendix 5000 and 5020 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up

More information

Through and Ground Conductor Terminal Blocks 290 Series

Through and Ground Conductor Terminal Blocks 290 Series 11 474 Through and Ground Conductor Terminal Blocks 290 Series 0.34-1. mm"f-st" 0.31-1 mm"s" 1 00 V/6 kv/3 2 1 AWG 22-16"f-st" AWG 22-18"s" I N 13. A Terminal block width mm / 0.197 in 0.34-1. mm"f-st"

More information

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation General Purpose Relays MKS Exceptionally Reliable General Purpose Relay now available with Lockable Test Button IEC Rating of A 0 V AC 0/0 Hz, General use 100,000 cycles. Mechanical indicator standard

More information

Incremental encoders With blind or through hollow shaft pulses per revolution programmable

Incremental encoders With blind or through hollow shaft pulses per revolution programmable Features Size mm Precise optical sensing Output signal level programmable (TTL or HTL) Blind or through hollow shaft, ø8 15 mm Connection axial, radial or tangential Pulses per revolution 1...65536, programmable

More information

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm. Perfect data processing I 7 I

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm. Perfect data processing I 7 I Temposonics Absolute, Non-Contact Position Sensors R-Series Temposonics RP and RH Measuring length 5-7600 mm Perfect data processing 0,5 µm Rugged Industrial Sensor Linear and Absolute Measurement LEDs

More information

Proportional pressure controller

Proportional pressure controller Proportional pressure controller Introduction I. Introducing : Proportional Pressure Controller Input signal I or E Output pressure The MAC Proportional Pressure Controller, (PPC) is an innovative product

More information

RT-3 UNIT RELAY 4-POINT TERMINAL

RT-3 UNIT RELAY 4-POINT TERMINAL Slim, Space-saving, -point Unit Relay RT-3 UNIT RELAY -POINT TERMINAL [PA Relay type, PhotoMOS Power (Voltage sensitive type)] RT-3 Unit relay -point Terminal [PA relay, PhotoMOS Power (Voltage sensitive

More information

Absolute Encoders Singleturn

Absolute Encoders Singleturn The absolute singleturn encoders Sendix 5853 SIL and 5873 SIL are perfectly suited for use in safety-related applications up to SIL3 according to DIN EN ISO 6800-5- or PLe to DIN EN ISO 3849. The extra

More information

SBE 320 / SBX 350 Connectors - up to 350 Amps

SBE 320 / SBX 350 Connectors - up to 350 Amps Connectors - up to 350 Amps ORDERING INFORMATION SBX and SBE connectors can integrate up to 8 auxiliary power / signal contacts along with the two primary power circuits. Sequencing within auxiliary positions

More information

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance 1 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1 guide... P.11~ General precautions... P.19 PHOTO PHOTO MEASURE panasonic.net/id/pidsx/global

More information

Thru-beam Sensors. Model SM800 Series. Ideal for small object detection

Thru-beam Sensors. Model SM800 Series. Ideal for small object detection Model SM800 Series MICROSONIC Thru-beam Sensors Ideal for small object detection Extremely reliable thru-beam sensing in a smaller package and ranges up to 1016 mm (40") They are miniature in size, powerful

More information

MEGA - AS-Interface version 3.0

MEGA - AS-Interface version 3.0 NEUMATIC SOOL VALVE ISLANDS by field bus with the following protocol MEGA - AS-Interface version. Installation manual NTERFACE MS-7-6.R GB CONTENTS age. The BUSLINK MEGA system with the AS-Interface protocol.

More information

Standard valves to ISO Product range overview

Standard valves to ISO Product range overview Standard valves to ISO 15218 Product range overview Function Electrical connection Voltage Manual override Page/Internet Pilot valve to ISO 15218 Plug connector Plug connector type C, to EN 175301-803

More information

REMA FLAT BLADE CONTACT CONNECTORS SR50 SR175 SR350

REMA FLAT BLADE CONTACT CONNECTORS SR50 SR175 SR350 REMA FLAT BLADE CONTACT CONNECTORS SR50 SR175 SR350 Productfeatures and advantages Reliable power connection solution for Electric vehicle batteries Battery chargers Forklift trucks Other DC voltage applications

More information

LSV(H)G Series High-speed Linear Servo Valves

LSV(H)G Series High-speed Linear Servo Valves LSV(H)G Series High-speed Linear Servo Valves LSVG-03 (3/8) & LSVHG-04/06/10 (1/2,3/4,1) Sub-plate Mounting LSVG/LSVHG Series High-Speed Linear Servo Valves offer extremely high response and excellent

More information

FITTINGS & GAUGES 20,000 PSI

FITTINGS & GAUGES 20,000 PSI PRESSURE GAUGE Features 4" high visibility face with laminated safety glass dial cover Accurate within +/- 0.5% of full scale range Stainless steel case and internals Heavy-duty movement Glycerine-filled

More information

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function. Ultrasonic Displacement Sensor Now, more advanced with a new mutual interference prevention function. Long-distance detection of up to 6,000 mm supports a wide variety of applications. The Sensor is not

More information

XV 1000 PARTS MANUAL Carousel ATC Fanuc / Siemens May 2007

XV 1000 PARTS MANUAL Carousel ATC Fanuc / Siemens May 2007 XV 1000 PARTS MANUAL Carousel ATC Fanuc / Siemens May 2007 Document Number 0705002A Issue A May 2007 XV1000 X Axis Assembly Drawing No. L-1060R0031 Feb-07 32 8-102003 M6 Spring Washer 8 33 8-101001 M6

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information