DATA TRANSMISSION CABLES
|
|
- Warren Stokes
- 6 years ago
- Views:
Transcription
1
2
3 DATA TRANSMISSION CABLES UTP 4x2x24 AWG Cat 5e 1- Conductor Solid copper wire 2- Insulation PE (ring coded) insulation 3- Cable core Pairs twisted in layers 4- Outer sheath PVC outer sheath (Ral-7001) These connection cables are used in telecommunication networks for transmission of either analog or digital signals. Maximum working transmission speed 100 Mbit/sn. Solid conductor of bare copper wire (0.51 mm), PE insulation. Cores twisted in pairs, four pairs twisted in layers. PVC-based compound of outer sheath, gray. TECHNICAL CHARACTERISTICS Impedance 100Ω± %15 in range of MHz Mutual Capacity Max. 56 nf/km (at 1 khz) Conductor Resistance Max. 94Ω/km Insulation Resistance Min MΩ km Working Temperature -30 C to + 70 C Working Voltage 250 volt Test Voltage 1200 volt Min. Bending Radius 25 mm Frequency (MHz) Return loss (SRL) (db) Attenuations (db/100 m) Next (Near-End crosstalk) (db)
4 DATA TRANSMISSION CABLES S/UTP 4x2x24 AWG Cat 5e F/UTP 4x2x24 AWG Cat 5e 1- Conductor Solid copper wire 2- Insulation PE (ring coded) insulation 3- Cable Base Pairs twisted in layers 4- Wrapping Tape PES tape 5- Drain wire Tinned copper wire 6- Screen ALPES tape 7- Outer Sheath PVC outer sheath, gray (Ral-7001) These connection cables are used in telecommunication networks for transmission of either analog or digital signals. Maximum working transmission speed 100 Mbit/sn. Solid conductor of bare copper wire (0.51 mm), PE insulation. Cores twisted in pairs, four pairs twisted in layers, over the base polyster foil wrapping tape, tinned copper drain wire, over the cable static screen of plastic coated aluminum foil (AL-PES). PVC-based compound of outer sheath, gray. TECHNICAL CHARACTERISTICS Impedance 100Ω± %15 in range of MHz Mutual Capacity Max. 56 nf/km (at 1 khz) Conductor Resistance Max. 94Ω/km Insulation Resistance Min MΩ km Working Temperature -30 C to + 70 C Working Voltage 250 volt Test Voltage 1200 volt Min. Bending Radius 25 mm Frequency (MHz) Return loss (SRL) (db) Attenuations (db/100 m) Next (Near-End crosstalk) (db)
5 STP 4x2x24 AWG Cat 5e F/FTP 4x2x24 AWG Cat 5e 1- Conductor Solid copper wire 2- Insulation PE (ring coded) insulation 3- Pairs Screened twisted pairs 4- Cable Base Pairs twisted in layers 5- Wrapping Tape PES tape 6- Drain Tinned copper wire 7- Screen AL-PES-AL tape 8- Outer Sheath PVC outer sheath, gray (RAL-7001) These connection cable are used in telecommunication networks for transmission of either analog or digital signals. Maximum working transmission speed 100 Mbit/sn. Solid conductor of bare copper wire (0.51 mm), PE insulation. Cores twisted in pairs, four individual screened pairs twisted in layers. Over the screened pairs twisted in layers; polyester tape, tinned copper wire and ALPESAL tape applied. PVC-based compound of outer sheath, gray. TECHNICAL CHARACTERISTICS Impedance 100Ω± %15 in range of MHz Mutual Capacity Max. 56 nf/km (at 1 khz) Conductor Resistance Max. 94Ω/km Insulation Resistance Min MΩ km Working Temperature -30 C to + 70 C Working Voltage 250 volt Test Voltage 1200 volt Min. Bending Radius 25 mm Frequency (MHz) Return loss (SRL) (db) Attenuations (db/100 m) Next (Near-End crosstalk) (db)
6 DATA TRANSMISSION CABLES C/STP 4x2x24 AWG Cat 5e S/FTP 4x2x24 AWG Cat 5e 1- Conductor Solid copper wire 2- Insulation PE (ring coded) insulation 3- Pairs Cores twisted in pairs 4- Drain Tinned solid copper wire 5-1 st Screen AL-PES-AL tape 6- Cable Base Four pairs twisted in layers 7-2 nd Screen Tinned copper wire braiding 8- Outer Sheath PVC outer sheath, gray (Ral-7001) These connection cables are used in telecommunication networks for transmission of either analog or digital signals. Maximum working transmission speed 100 Mbit/sn. Solid conductor of bare copper wire (0.51 mm), PE insulation. Cores twisted in pairs and drain tinned copper wire covered with plastic coated aluminum foil (AL-PES-AL). Four pairs twisted in layers. Screen braiding of tinned copper wire. Outer sheath of PVC-based compound, gray. TECHNICAL CHARACTERISTICS Impedance 100 Ω± %15 in range of MHz Mutual Capacity Max. 56 nf/km (at 1 khz) Conductor Resistance Max. 94Ω/km Insulation Resistance Min MΩ km Working Temperature -30 C to + 70 C Working Voltage 250 volt Test Voltage 1200 volt Min. Bending Radius 25 mm Frequency (MHz) Return loss (SRL) (db) Attenuations (db/100 m) Next (Near-End crosstalk) (db)
7 U/UTP 4x2x26 AWG Cat 5e F/UTP 4x2x26 AWG Cat 5e 1- Conductor Stranded copper wire (7x0.16 mm) 2- Insulation PE (ring coded) insulation 3- Cable Core Pairs twisted in layers 4- Outer Sheath PVC outer sheath, gray (Ral-7001) These connection cables are used in telecommunication networks for transmission of either analog or digital signals. Maximum working transmission speed 100 Mbit/sn. Fine stranded copper wire (7x0.16 mm), PE insulation. Cores twisted in pairs, four pairs twisted in layers. PVCbased compound of outer sheath, gray. TECHNICAL CHARACTERISTICS Impedance 100 Ω±%15 in range of MHz Mutual Capacity Max. 56 nf/km (at 1 khz) Conductor Resistance Max. 138.Ω/km Insulation Resistance Min MΩ km Working Temperature -30 C to + 70 C Working Voltage 250 volt Test Voltage 500 volt Min. Bending Radius 25 mm Frequency (MHz) Return loss (SRL) (db) Attenuations (db/100 m) Next (Near-End crosstalk) (db)
8 DATA TRANSMISSION CABLES FS/UTP 4x2x24 AWG Cat 5e F/UTP 4x2x24 AWG Cat 5e 1- Conductor Stranded copper wire (7x0.20 mm) 2- Insulation PE (ring coded) insulation 3- Cable Core Pairs twisted in layers 4- Wrapping Tape Polyster tape 5- Drain Multi stranded tinned copper wire 6- Screen AL-PES tape 7- Outer Sheath PVC outer sheath, gray (Ral-7001) These connection cable are used in telecommunication networks for transmission of either analog or digital signals. Special flexible design for patch panels. Maximum working transmission speed 100 Mbit. Fine stranded cooper wire (7x0.20mm) conductor, solid PE insulation. Cores twisted in pairs, four pairs twisted in layers. Polyster wrapping tape. Multi stranded tinned copper wire drain wire. Screen of plastic coated aluminum foil. PVC-based compound of outer sheath, gray. (RAL 7001) TECHNICAL CHARACTERISTICS Impedance 100 Ω±%15 in range of MHz Mutual Capacity Max. 56 nf/km (at 1 khz) Conductor Resistance Max. 88.Ω/km Insulation Resistance Min MΩ km Working Temperature -30 C to + 70 C Working Voltage 250 volt Test Voltage 1200 volt Min. Bending Radius 25 mm Frequency (MHz) Return loss (SRL) (db) Attenuations (db/100 m) Next (Near-End crosstalk) (db)
9 FC/UTP 4x2x26 AWG Cat 5e S/UTP 4x2x26 AWG Cat 5e 1- Conductor Stranded copper wire (7x0.16 mm) 2- Insulation PE (ring coded) insulation 3- Cable Core Pairs twisted in layers 4- Wrapping Tape Polyster tape 5- Screen Tinned copper wire braiding 6- Outer Sheath PVC outer sheath, gray (Ral-7001) These connection cables are used in telecommunication networks for transmission of either analog or digital signals. Special flexible design for patch panels. Maximum working transmission speed 100 Mbit. Fine stranded copper wire (7x0.20 mm) conductor, solid PE insulation. Cores twisted in pairs, four pairs twisted in layers. Polyster wrapping tape. Screen braiding of tinned copper wire. Outer sheath of PVC-based compound, gray (RAL 7001). TECHNICAL CHARACTERISTICS Impedance 100 Ω±%15 in range of MHz Mutual Capacity Max. 56 nf/km (at 1 khz) Conductor Resistance Max. 138.Ω/km Insulation Resistance Min MΩ km Working Temperature -30 C to + 70 C Working Voltage 250 volt Test Voltage 1200 volt Min. Bending Radius 26 mm Frequency (MHz) Return loss (SRL) (db) Attenuations (db/100 m) Next (Near-End c rosstalk) (db)
10 DATA TRANSMISSION CABLES UTP 4x2x24 AWG Cat 6 1- Conductor Solid copper wire (0.51 mm) 2- Insulation Polyolefin (ring coded) 3- Cable Core Pairs twisted in layers 4- Outer Sheath PVC-based, gray (Ral-7001, Ral-7032) These connection cables are used in telecommunication networks for transmission of either analog or digital signals. Maximum working transmission speed 125 Mbit/sn. Solid conductor of bare copper wire (0.51 mm), Polyelefin insulation. Cores twisted in pairs, four screened pairs twisted in layers. PVC-based compound of outer sheath, gray. TECHNICAL CHARACTERISTICS Impedance 100 Ω±%15 in range of MHz 100 Ω±%22 in range of 125 MHz Efective Capacity Max. 56 nf/km (at 1 khz) Conductor Resistance Max. 94.Ω/km Insulation Resistance Min MW.km Temperature Range -30 C to + 70 C Working Voltage 250 volt Test Voltage 1200 volt Min. Bending Radius 25 mm Frequency (MHz) Return loss (SRL) (db) Attenuations (db/100 m) Next (Near-End crosstalk) (db)
11 RS 232/00 1- Conductor Fine stranded tinned annealed copper wire 2- Insulation PVC insulation 3- Wrapping Tape PES tape 4- Drain Stranded tinned copper wire 5- Screen Tinned copper wire braiding 6- Outer Sheath PVC outer sheath, gray (Ral-7032) These connection cables are used in telecommunication networks and electronic control systems for signal transmission. Fine stranded tinned annealed copper wire, semi rigid PVC-based insulation. Cores twisted in pairs, pairs twisted in layers, polyster wrapping tape with drain stranded annealed tinned copper wire. Screen braiding of tinned copper wire. Outer sheath of PVC- based compound, gray (RAL-7032). TECHNICAL CHARACTERISTICS Mutual Capacity AWG : max. 100 nf/km AWG 20 : max. 120 nf/km Working Temperature -30 C to + 70 C Insulation Resistance 50 MΩ Working Voltage 250 volt Test Voltage 1200 volt Min. Bending Radius 15xCable diameter Number of cores and Approx. outside diameter (mm) Copper factorial (per km) Approx. weigth (kg/km) cross-section (mm 2 ) DAT-232/00 AWG 24 2x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x
12 DATA TRANSMISSION CABLES RS 232/00 Number of cores and Approx. outside diameter (mm) Copper factorial (per km) Approx. weigth (kg/km) cross-section (mm 2 ) DAT-232/00 AWG 24 18x2x x2x x2x DAT-232/00 AWG 22 2x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x DAT-232/00 AWG 20 2x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x
13 RS 422/00 1- Conductor Stranded tinned copper wire 2- Insulation PE insulation 3- Wrapping Tape Polyster tape 4- Screen AL-PES tape 5- Drain Stranded tinned copper wire 6- Screen Tinned copper wire braiding 7- Outer Sheath PVC outer sheath, gray (Ral-7032) These connection cables are used in telecommunication networks and electronic control systems for signal transmission. Fine stranded tinned annealed copper wire, PE core insulation. Cores twisted in pairs, pairs twisted in layers, polyster wrapping tape. Screen of aluminum coated polyester foil. Screen braiding of tinned copper wire with tinned copper wire drain. Outer sheath of PVC- based compound, gray. (RAL-7032) TECHNICAL CHARACTERISTICS Mutual Capacity max. 50 nf/km Working Temperature -30 C to + 80 C Insulation Resistance 5 GΩkm Working Voltage 250 volt Test Voltage 1200 volt Min. Bending Radius 15xCable diameter Number of cores and Approx. outside diameter (mm) Copper factorial (per km) Approx. weigth (kg/km) cross-section (mm 2 ) DAT-422/00 AWG 24 2x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x
14 DATA TRANSMISSION CABLES RS 422/00 Number of cores and Approx. outside diameter (mm) Copper factorial (per km) Approx. weigth (kg/km) cross-section (mm 2 ) DAT-422/00 AWG 22 2x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x DAT-422/00 AWG 20 2x2x x2x x2x x2x x2x x2x x2x x2x
15 TWINAXIAL 105 Ω 1- Conductor Solid electrolitic copper wire 2- Insulation Foam PE 3- Paired cores Two cores twisted in pairs 4-2nd Screen Braiding of tinned copper wire 5-3rd Screen AL-PES-AL 6-4th Screen Braiding of tinned copper wire 7- Outer Sheath PVC compound, gray These LAN data transmission cables are used for ethernet networks. Can be used to link main units, Data transmission speed is 10 mbit/s. Solid electrolitic copper wire, Foam PE insulation. Screen of aluminum coated polyester foil (AL-PES). Screen braiding of tinned copper wire. Screen of aluminum coated polyester foil; two sided (AL-PES-AL). Screen braiding of tinned copper wire. Outer sheath of PVC compound, yellow. TECHNICAL CHARACTERISTICS Impedance Efective capacity Conductor resistance Insulation resistance Temperature range Working voltage Test voltage Min. bending radius 50 ± 2Ω max. 85 nf/m max. 4.7 Ω/km min MΩ km -30 C to +70 C max. 2.5 V max. 5.0 V 200 mm Frequency (MHz) Attenuation (db/100 m)
16 DATA TRANSMISSION CABLES RG-62 A/U INDOOR 1- Conductor Copper clad steel wire 2- Insulation Semi-solid PE insulation 3- Screen Annealed copper wire braiding 4- Outer sheath PVC outer sheath, black These data transmission cables are used IBM networks as data transmission cable. No outdoor use. Copper clad, steel wire, semi-solid PE-air spaced-insulation. Screen braiding of electrolitic annealed copper wire. Outer sheath of PVC compound, black. TECHNICAL CHARACTERISTICS Impedance Mutual capacity Conductor resistance Insulation resistance Working temperature Working voltage Test voltage Min. bending radius 93 ± 5Ω max. 43 pf/km max. 144 Ω/km (29ºC) min MΩ km -40 C to +70 C max. 2.5 kv max. 5.0 kv 5xD mm Frequency (MHz) Attenuation (db/100 m)
17 RG-62 A/U OUTDOOR 1- Conductor Copper clad steel wire 2- Insulation Semi-solid PE insulation 3- Screen Annealed copper wire braiding 4- Wrapping tape Polyester tape 5- Outer sheath PVC outer sheath, black These data transmission cables are used IBM networks as data transmission cable. Application for outdoor use. Copper clad, steel wire, semi-solid PE-air spaced-insulation. Screen braiding of electrolitic annealed copper wire. Outer sheath of PE compound, black. TECHNICAL CHARACTERISTIC Impedance Mutual capacity Conductor resistance Insulation resistance Working temperature Working voltage Test voltage Min. bending radius 93 ± 5Ω max. 43 pf/km max. 144 Ω/km (29ºC) min MΩ km -40 C to +70 C max. 2.5 kv max. 5.0 kv 5xD mm Frequency (MHz) Attenuation (db/100 m)
18 DATA TRANSMISSION CABLES RG-59 / U-4 1- Conductor Ø 0.83 mm electrolitic copper wire 2- Insulation Ø 3.90 mm foam polyethylene insulation 3-1 st Screen AL-PES tape 4-2 nd Screen Tinned copper wire braiding 5- Outer sheath PVC outer sheath, Ø 6.0 mm, white Used as connection cable in CATV, CCTV and satellite and common antenna TV systems. Electrolitic annealed copper wire conductor. Foam Polyethylene insulation. Screen of plastic coated aluminum foil AL-PES-AL (100% coverage). Screen braiding of tinned copper wire (85% coverage). Outer sheath of PVC compound, white. TECHNICAL CHARACTERISTICS Impedance Mutual capacity Conductor resistance Insulation resistance Working temperature Working voltage Test voltage Min. bending radius 75 ± 3Ω max.61 pf/km max. 144 Ω/km (29ºC) min MΩ km -40 C to +70 C max. 1.1 kv 2.5 kv 10xD mm Frequency (MHz) Attenuation (db/100 m)
19 TVVF-F2/TVGF 1- Conductor Solid conductor 2- Insulation PVC or halogen-free insulation 3- Wrapping Polyester tape 4- Drain wire Solid tinned copper 5- Screen ALPES tape 6 6- Outer sheath Flame retardant PVC or halogen-free outer sheath Flame retardent or halogen free telephone and fire alarm systems cables for interior installations. Solid bare copper conductor, PVC or halogen free insulated, cores twisted in pairs, pairs twisted in layers over the base polyester foil wrapping tape, tinned copper drain wire over the cable static screen of plastic coated aluminum foil (ALPES). temperature range Occasional flexing -5 C to +70 C Fixed installation -30 C to +70 C test voltage 1000 V (AC) bending radius 10xD FIRE PERFORMANCE Flame retardant No flame propagation IEC , DIN EN /-2-1, VDE 0482 P265-1/2-1 IEC /-3-24, DIN EN /-2-4, VDE 0482 P266-1/-2-4 MATERIAL PROPERTIES FOR HALOGEN FREE Halogen-free IEC , VDE 0482 P , DIN EN No corrosive gases IEC , VDE 0482 P , DIN EN Low smoke emission IEC /-2, VDE 0482 P268-1/-2, DIN EN /-2 17
20 DATA TRANSMISSION CABLES TVVF-F2/TVGF Number of cores x Approx. outside diameter (mm) Net weight approx.(kg/km) nominal conductor diameter (mm) 1x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x
21 TWAVB 1- Conductor Solid bare conductor 2- Insulation PE insulation 5 3- Filler Extruded PVC filler 4- Armour 2Galvanized steel tape with drain wire or galvanized steel wires 5- Outer Sheath Flame retardant PVC outer sheath Telephone and signalisation cables, cores twisted in pairs, armoured and flame retardant, for outdoor installations. Solid bare copper conductor, Polyethylene insulated, armoured and flame retardant PVC outer sheathed cables. temperature range Occasional flexing -5 C to +70 C Fixed installation -30 C to +70 C test voltage bending radius 1000 V (AC) 15xD FIRE PERFORMANCE Flame retardant IEC , DIN EN /-2-1, VDE 0482 P265-1/2-1 Number of cores x Approx. outside diameter (mm) Net weight approx.(kg/km) nominal conductor diameter (mm) 1x4x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x
22 DATA TRANSMISSION CABLES SVV-F2/SVG-F2 1- Conductor Solid bare conductor 2- Insulation PVC or halogen-free insulation 3- Outer Sheath Flame retardant PVC or halogen-free outer sheath Telephone and signalisation cables, cores laid up concentric layers and flame retardant, for interior installations. Halogen free version is SVG-F2. Solid bare copper conductor, PVC or halogen-free insulated, flame retardant PVC or halogen-free outer sheathed (low smoke) cables. temperature range Occasional flexing -5 C to +70 C Fixed installation -30 C to +70 C test voltage 2500 V (AC) bending radius 15xD FIRE PERFORMANCE Flame retardant No flame propagation IEC , DIN EN /-2-1, VDE 0482 P265-1/2-1 IEC /-3-24, DIN EN /-2-4, VDE 0482 P266-1/-2-4 MATERIAL PROPERTIES FOR HALOGEN FREE Halogen-free IEC , VDE 0482 P , DIN EN No corrosive gases IEC , VDE 0482 P , DIN EN Low smoke emission IEC /-2, VDE 0482 P268-1/-2, DIN EN /-2 Number of cores x Approx. outside diameter (mm) Net weight approx.(kg/km) nominal conductor diameter (mm) 2x x x x x x x x x x
23 TPVF-F2/TPGF 1- Conductor Solid tinned conductor 2- Insulation PE insulation 3- Pairs Screened twisted pairs 4- Cable Base Pairs twisted in layers 5- Drain Solid tinned copper wire 6- Wrapping Polyester tape 5 7- Outer Sheath Flame retardant PVC or halogen free outer sheath Telephone and signalisation cables, cores twisted in pairs and pairs shielded, flame retardant, for interior installations. Halogen free version is TPGF. Solid tinned copper conductor, Polyethylene insulated, flame retardant PVC or halogen-free (low smoke) outer sheathed cables. temperature range Occasional flexing -5 C to +70 C Fixed installation -30 C to +70 C test voltage 1000 V (AC) bending radius 10xD FIRE PERFORMANCE Flame retardant No flame propagation EC , DIN EN /-2-1, VDE 0482 P265-1/2-1 IEC /-3-24, DIN EN /-2-4, VDE 0482 P266-1/-2-4 MATERIAL PROPERTIES FOR HALOGEN FREE Halogen-free IEC , VDE 0482 P , DIN EN No corrosive gases IEC , VDE 0482 P , DIN EN Low smoke emission IEC /-2, VDE 0482 P268-1/-2, DIN EN /-2 Number of cores x nominal conductor diameter (mm) Approx. outside diameter (mm) Net weight approx. (kg/km) 1X2X X2X X2X X2X X2X X2X X2X X2X X2X X2X X2X X2X X2X Number of cores x nominal conductor diameter (mm) Approx. outside diameter (mm) Net weight approx. (kg/km) 1X2X X2X X2X X2X X2X X2X X2X X2X X2X X2X X2X X2X X2X X2X
24 DATA TRANSMISSION CABLES VVT-F2/GGT-F2 1- Conductor Solid tinned conductor 2- Insulation PVC or halogen-free insulation 3- Earth Wire PVC or halogen-free insulated solid tinned copper 4- Wrapping Tape Polyester tape 5- Outer Sheath Flame retardant PVC or halogen-free outer sheath Telephone and signalisation cables, twisted pairs laid up concentric layers with insulated earth wire and flame retardant, for interior installations. Halogen free version is GGT-F2. Solid tinned copper conductor, PVC or halogen-free insulated, flame retardant PVC or halogen-free outer sheathed (low smoke) cables. temperature range Occasional flexing -5 C to +70 C Fixed installation -30 C to +70 C test voltage 1000 V (AC) bending radius 20xD FIRE PERFORMANCE Flame retardant No flame propagation IEC , DIN EN /-2-1, VDE 0482 P265-1/2-1 IEC /-3-24, DIN EN /-2-4, VDE 0482 P266-1/-2-4 MATERIAL PROPERTIES FOR HALOGEN FREE Halogen-free IEC , VDE 0482 P , DIN EN No corrosive gases IEC , VDE 0482 P , DIN EN Low smoke emission IEC /-2, VDE 0482 P268-1/-2, DIN EN / /-2 22
25 VVT-F2/GGT-F2 Number of cores x Approx. outside diameter (mm) Net weight approx.(kg/km) nominal contuctor diameter (mm 2 ) 1x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x x2x
26 DATA TRANSMISSION CABLES LOUD SPEAKER 1- Conductor Fine stranded copper conductor 2- Insulation PVC insulation 2 1 These cables are used in professional broadcasting systems for the transmission of analogue audio signals. The cable consists of stranded multiwire copper conductors and PVC insulated according to BS EN standard. Type Nominal cable dimension MAX. conductor Weight (Thicknessx width) (mm) resistance (Ohm/km) (kg/km) 2x x x x x x x x x x x x x x x x
27 Technical Data British and US Dimensions for Cable and Leads In the US area of influence the dimensions of copper conductors for power and data transmission purposes are usually expressed in AWG Nos*. The corresponding values are: AWG Diameter Cross-section Conductor resistance No. mm mm² Ω/km / / / / AWG Diameter Cross-section Conductor resistance No. mm mm² Ω/km General Dimensions The basic units are in the English gravitational system in the English obsolute system Lenght (ft)-force (lbf=lb)-time (s) Lenght (ft)-mass (lb)-time (s) Lenght Dimensions Cubic Dimensions 1 ml = mm 1 cubic inch =16.39 cm³ 1 inch (in, ) =25.4 mm 1 cubic foot = cm³ 1 foot (ft, ) =0.305 m 1 cubic yard = mm² 1 yard (yd) = m 1 US liquid galon = chain (ch) =20.1 m 1 pint = statue mile = 1.61 km 1 quart = nautical mile = km 1 brit gallon = statue mile = 1760 yards 1 barrel = Area Dimensions 1 circ. mil (CM) = ³ mm² 1 MCM = mm² 1 square inch (sg. in.) = mm² 1 square foot (sq. ft.) = m² 1 square yard = m² 1 acre = km² 1 square mile = 2.59 km² 1m2 = sq. ft. Mass Units English gravitation system 1 slug = 1 lbs s²/ft English 1 pound = 1 lb 1 slug = lb, with ft/s² as the standard value of acceleration due to grativity. Conversion to metric units 1 grain = mg 1 dram = g 1 ounce (oz) = 16 drams = g 1 pound (lb) = 16 oz = g 1 stone = 14 lbs = 6.35 kg 1 US ton (short ton) = t 1 Brit. Ton (long ton) = t Units of Force English gravitational systems: pound-force 1 lbf = 1 Lb English absolute systems: poundal 1 pdl = 1 lb ft / s² 1 lbf = pdl lb m/s² Conversion to metric units 1 pound-force (lbf) = kp 1 Brit. ton force = 1016 kp 1 poundal (pdl) = N 1 lbf = N Electrical units per unit lenght Density 1 μf per mile =0.62μF/km 1 lb/ft3 = kg/m³ 1 megohm per mile = 1.61 MΩ km 1 decibel per mile = 71.5 m/n/km Weight (specific weight) 1 μf per foot =3.28 pf/m 1 lbf/ft3 = kp/m³ 1 decibel per 100 ft =3.77 N/km 1 ohm per 1000 ft = 3.28 Ω /km Copper wire weight per mile 1 ohm per 1000 yd = Ω/km lb/ mile Ø mm Weight per unit lenght lb per foot = kg/m lb per yard = kg/m lb per mile = kg/m Units of Energy 1 horsepower = kw (H.P.) 1 brit. therm unit = kcal The insulation wall thicknesses are often expressed in n/64 inches, 1.64 inch being rougly equal to 0.4 mm Further dimensions for wire weights and for electrical field strengths: lbf pr. MFeet = kg/km 40 V/mil =1.6 kv/mm lbf pr. Mile = kg/km 80V/mil = 3.2 kv/mm 100V/mil =4.0 kv/mm 250V/mil =10.0 kv/mm 25
28 DATA TRANSMISSION CABLES Drum Capacities for Plastic-Insulated Cable in Metres to DIN Reel Cables TYPE Diameter in mm Width in mm Max. load Weight Drum No Drum size d1 d2 d4 L1 L4 kg kg / / / / / / / / / / / / /
29 DIN Colour Codes The colour code for DEMTRONIK and DEMFLEKS cables is in accordance with DIN 47100/Nov In each pair there is always one A-core and one B-core. Upwards of 23 pairs, the identification repeats itself for the first time and from 45 pairs fort he second time. The first is always the basic colour of the core and the second colour is applied in ring-form. No of Pairs Colour a-core Colour b-core No of Pairs Colour a-core Colour b-core 1 white brown 13 white/black brown/black 2 green yellow 14 grey/green yellow/grey 3 grey pink 15 pink/green yellow/pink 4 blue red 16 green/blue yellow/blue 5 black violet 17 green/red yellow/red 6 grey/pink red/blue 18 green/black yellow/ black 7 white/green brown/green 19 grey/blue pink/blue 8 white/yellow yellow/brown 20 grey/red pink/red 9 white/grey grey/brown 21 grey/black pink/black 10 white/pink pink/brown 22 blue/black red/black 11 white/blue brown/blue see above see above 12 white/red brown/red see above see above DIN Colour Codes (without colour repetition) The core insulation gives the first colour the second colour is provided by a coloured ringing or band. Where three colours are specified the second and third colours are printed alternately over the basic colour (1 st colour). 1 white 22 brown/ blue 43 blue/black 2 brown 23 white/red 44 red/black 3 green 24 brown/red 45 white/brown/black 4 yellow 25 white/black 46 yellow/green/black 5 grey 26 brown/black 47 grey/pink/black 6 pink 27 grey/green 48 red/blue/black 7 blue 28 yellow/grey 49 white/green/black 8 red 29 pink/green 50 brown/green/black 9 black 30 yellow/pink 51 white/yellow/black 10 violet 31 green/blue 52 yellow/brown/black 11 grey/pink 32 yellow/blue 53 white/grey/black 12 red/blue 33 green/red 54 grey/brown/black 13 white/green 34 yellow/red 55 white/pink/black 14 brown/green 35 green/black 56 pink/brown/black 15 white/yellow 36 yellow/black 57 white/blue/black 16 yellow/brown 37 grey/blue 58 brown/blue/black 17 white/grey 38 pink/blue 59 white/red/black 18 grey/brown 39 grey/red 60 brown/red/black 19 white/pink 40 pink/red 61 black/white 20 pink/brown 41 grey/black 21 white/blue 42 pink/black LAN (Local area network) a-wire pair nr. b-wire white-blue 1 blue white-orange 2 orange white-green 3 green white-brown 4 brown 27
30 DATA TRANSMISSION CABLES Network Structure Ring Star Bus Mesh Tree CODE DESIGNATION ACCORDING TO VDE ACR Attenuation to Crosstalk Ratio ISDN Integrated Services Digital Network BD Building Entrance Facilities ISO International Organisation for Standardization BFOC B-ISDN Bayonet Fibre Optic Connector Broadband ISDN ITU-T International Telecommunication Union Telecommunication Standardization Bureau (formerly CCITT) BRI Basic Rate ISDN JTC Join Technical Commitee CD Campus Distributor LAN Local Area Network c Speed of light LCL Longitudinal Conversion Loss CISPR International Special Committee on Radio Interference LCTL Longitudinal Conversion Transfer Loss CSMA/CD Carrier Sence Miltiple Access with Collision Detection N/A Not Applicable DCE Data Circuit Terminating Equipment N-BNC N type to BNC Convertor DTE Data Terminal Equipment NEXT Near And Crosstalk DUT Device Under Test OTDR Optical Time Domain Reflectometer EMC Electromagnetic Compability PBX Private Branch Exchange EMI Electromagnetic Interference PDAM Proposed Draft Amendment ER Equipment Room PMD Physical Layer Medium Dependent FD Floor Distributor SC Subsscriber Connector (Optical fibre connector) FDDI Fibre Distributed Data Interface SC-D Duplex SC connector FOIRL Fibre Optic Inter-Repeater Link STI Surface Transfer Impedance FWHM Full Width Half Maximum TC Telecommunications Closet IC Integrated Circuit TDR Time Domain Reflectometer IDC Insulation Displacement Connection TO Telecommunications Outlet IEC International Electrotechnical Commission TP Transition Point CAT2 CAT3 CAT4 CAT5 Frequency Attenuation Next Attenuation Next Attenuation Next Attenuation Next MHz db/100m (max) db (min) db/100m (max) db (min) db/100m (max) db (min) db/100m (max) db (min) Cable level Data speed 1 ve 2 Ses Frekans Sistemleri 3 10 MBit/s 4 16 MBit/s MBit/s MBit/s 28
31 NOTE
32 NOTE
33 NOTE
34 NOTE
35
36 DEMES KABLO SAN. TİC. LTD. ŞTİ Kıraç Bel. 3. Bölge Feyzi Çakmak Cd. No: 56 B. Çekmece - İST Telefon: /Pbx Faks:
COPPER + LWL RAW CABLES
COPPER + LWL RAW Twisted Pair Cables... 112 TV/SAT Cables... 116 Fiber Optic Raw Cables... 120 DIGITUS CAT 7 twisted pair installation cable 4x2xAWG23 S-FTP CAT 7 1000 MHz LSZH installation cable For installation
More informationFor information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.
Telecommunication and fire alarm cables For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation. J-YY Bd 14 J-YY BMK 15 J-Y(St)Y Lg 16 J-Y(St)Y
More informationNETWORK CONNECTIVITY SYSTEMS
NETWORK CONNECTIVITY SYSTEMS Installation Cable KS-STP Category 7 Installation Cable Certificates 10GBaseT FTP Category 6 Installation Cable UTP Category 6 Installation Cable UTP Category 5E Installation
More informationInformation technology. Generic cabling systems, General requirements
KRAMER WELL CONNECTED WITH KRAMER BCLS-33OR-5 Al-Mylar Conductor CAT6A F/UTP LSZH Cable Drain Wire Kramer s BCLS-33OR is a high performance CAT6A F/UTP cable designed for IT, LAN and Ethernet installations.
More informationTwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm
name: TKF article number: 10305 description Nr.: POE- PS- 10305 PT F F F 800 B C 1 2 3 4 5 6 7 Assembly: 1. Primary tube 5 mm 2. CAT 5 E FTP cable 3. CAT 5 E FTP cable 4. Bus cable 5. Coax 9 cable 6. Separation
More informationMultimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION BUILDING MANAGEMENT SYSTEMS
Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION SOLUTIONS COAXIAL CABLES BUILDING MANAGEMENT SYSTEMS BROADCASTING & STUDIO Prysmian Group Linking
More informationData sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2
Page 1/7 Illustrations Principle diagram See enlarged drawings at the end of document Product specification 10 GBit installation cable, simplex installation cable Cat.7A AWG 22 S/FTP with wires shielded
More informationData sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft
Page 1/6 MC GC0 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft 18427034141 Illustrations Principle diagram Product specification 10 GBit installation cable, simplex installation cable Cat.7 AWG 23 S/FTP with wires
More informationUNIRAIL D RS485 and BUS cables
UNIRAIL D RS485 and BUS cables Type: 1x2x22 AWG/7 + 1x22 AWG/7 (1x2x0,35 + 1x0,35) Code: RW103A stranded tinned copper wire 22 AWG/7 (0,35 mm²) white blue POWER ELEMENTS: stranded bare copper wire 22 AWG/7
More informationInstrumentation Cable PLTC/ITC and TC Types
Instrumentation Cable PLTC/ITC and TC Types The Quality Connection 2 The Quality Connection Product range Telecommunication cables Data- and Bus cables (copper and fiber optic) Mining cables Cables for
More informationShip Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4
Wiking Ship Hybrid Cable Application Hybrid cable for shipboard applications DATA ELEMENT Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T
More informationData sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft
Page 1/7 Illustrations Principle diagram Product specification 10 GBit installation cable, duplex installation cable Cat.7A AWG 22 S/FTP with wires shielded in pairs 2x4 pairs (PiMF) pair shield: plastic
More informationDB EN valid from: Application SERVO LK SMS FX8PLUS SIGNAL
Application LAPP servo cables according to Siemens * (see footnote) Standard FX8008 PLUS SIGNAL are a new generation of very highly flexible screened signal (encoder and resolver)- cables (P/Ns 00277101
More informationEC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s
EC 200 EC200 - Rev. 3-23.06.11 Characteristic impedance 50 ± 2 Material copper wire Nominal capacity (pf/m) 80.5 Construction - Relative propagation velocity (%) 83 Diameter (mm) 1.05 Inductance (µh/m)
More informationMULTIMEDIA CABLE H6091ZHB
CAVEL News MULTIMEDIA CABLE H6091ZHB MULTIMEDIA CABLE H6091ZHB Multimedia is a must in the modern way of life. Growing communication needs in any environment whether at home or the office the connection
More informationShip and Offhsore. Approved cables for ship- and offshoreindustry
Ship and Offhsore Approved cables for ship- and offshoreindustry NEK Kabel AS - Norway. (NEK Sealine Marine products) tel. +47 67 91 21 80 - Firmapost@nek-kabel.no 1 OVER 100 YEARS OF EXPERIENCE 1913-2013
More informationCUSTOM DESIGN COAXIAL CABLES BY SICAB
CUSTOM DESIGN COAXIAL CABLES BY SICAB. COAX RG 58 C/U Application: Coaxial Cable 50 Ohm For indoor installation as well as in industrial areas in conduits and cable ducts, for transmission of high frequency
More informationAddison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:
Addison www.addison-tech.com www.addison-cables.com Profibus SK Indoor + Outdoor Application: The application of these Profibus SK cables are in the cell and field area, just as for conventional types.
More informationEXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)
XTRA GUARD 1 MULTICONDUCTOR, SUPRASHIELD EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE UL TYPE CM, AWM 2464 CSA CMG FT4 300 VOLT 34 CHOOSE XTRA GUARD 1FOR: Unsurpassed Flame and Moisture Resistance
More informationContent. - DDF Frame Pair Screen Cable Pair Screen Cable
Content - 120 1.1 Ohm 120ohm DDF DDF Accessories Cables 1.1.1 2 Pair Screen Cable - DDF Frame 1.1.2 4 Pair Screen Cable - 120 Ohm 1.1.3 DDF 8 Pair Cable Screen Cable 1.1.4 16 Pair Screen Cable 1.1.5 50
More informationCaledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:
Caledonian www.caledonian-cables.co.uk www.caledonian-cables.net Profibus L2 Indoor Application: This system cable is used to interconnect L2-BUS components. This cable is an economical solution for the
More informationK20 & L120 LSZH Armoured F/FTP Cat6 Cables
K20 & L120 LSZH Armoured F/FTP Cat6 Cables The cables are designed for high speed data transmissions, and are suitable for installations in cable trays or on hooks. RATP CAT6-K20 (for K20 cable) FRANCE
More informationCAT 5e UTP Cable: NETSET BOX [305m], indoor
Code: E08_05 CAT 5e UTP Cable: NETSET BOX [05m], indoor NETSET BOX UTP 5e Ethernet cable far exceeds the requirements for Category 5e twisted pair cables. View of the cable box - inside 05m of the cable.
More informationData sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m
Page 1/6 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12-jack to RJ45-plug Ethernet connection line Cat.5, 4-pole, D-coded (IEC
More informationCoax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3
Overview Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3 Example drawing (see the chapter belonging to the cable for details) (see the chapter belonging
More informationSelection table for flat & ribbon cables
Just click on the products in the selection table. Click on the HELUKABEL logo at the end of the page to go back. Cables & Wires Selection table for flat & ribbon cables www.helukabel.com FLAT & RIBBON
More informationCopyright June Nexans
Nexans is the worldwide leader in the cable industry, with an industrial presence in 29 countries and commercial activities in 65 countries. Nexans brings an extensive range of advanced copper and optical
More informationDetailed Specifications & Technical Data
For more Information please call 1-800-Belden1 Description: Banana Peel Composite - (2) Cat 5e 4-pair 24 AWG unshielded plus (2) Series 6 Coax with Duobond IV Quad shield, polyolefin insulation on the
More informationInstall & Go Cat.8 S/FTP Trunk Cable Assembly Description
Description Cat 8 Filler Cat.8.2 S/FTP Horizontal cables (x6) Fan-Out Cables Cat 8 STP Keystones TRUNK CABLE SECTION VIEW Assembly Isometric Front View RiT s Copper Install & Go System provides a pre-terminated
More informationFilled Solid ALPETH Cable
I. Exchange Cables Filled Solid ALPETH Cable REA/RUS PE-39 2.39.01 CONDUCTORS: Solid, annealed copper wires, in 2, 24, 22 and 19 AWG. INSULATION: Solid, high-density polyeylene or polypropylene in distinctive
More informationIndustrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.
Industrial Ethernet Petrol Forecourt Cable (Solid) 3014P24S1001 Industrial Ethernet Petrol Forecourt Cable (Solid) 3014P24S1001-10 Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.
More informationDetailed Specifications & Technical Data
Description: Series 11, 14 AWG solid.064" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond IV quad shield (60% and 40% coverage), PVC jacket Physical Characteristics
More informationList Price w.e.f. 02nd January, 2018
w.e.f. 02nd January, 2018 HRFR/FR-LSH/HFFR/ PVC Insulated Industrial Cables Multicore Round PVC Cables Flat Three Core Industrial Cable for Sumersible use Telecom & Co-axial Cables LAN Cables CCTV Cables
More informationDetailed Specifications & Technical Data
Description: 24 AWG stranded (7x32) TC conductor, Datalene insulation, pairs individually shielded with bonded Beldfoil with a drain wire and have numbered and color-coded PVC jackets, overall Beldfoil
More informationCIR (Crush & Impact Resistant) VFD Power Cable
37-2 CIRVFD CIR (Crush & Impact Resistant) VFD Power Cable Gexol Insulated Three Conductor 2kV Rated 90 C UL Listed as Type TC-ER Power Conductors (x3) Soft annealed flexible stranded tinned copper per
More informationData sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations
Page 1/7 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection cable drag chain suitable Cat.6A, 8 pole, X-coded
More informationDetailed Specifications & Technical Data
For more Information please call 1-800-Belden1 General Description: PTZ (CCTV+Control+Power) Cable, Rated-CM, 1-RG59 20 AWG solid bare copper with foam polyolefin, 95% bare copper braid, 1-22 AWG stranded
More information16-2-C Series. Specification Table. Page <1> 19/06/10 V1.0. : Varies with colour and packing.
: Varies with colour and packing. Description : Sub-miniature Cable, 16-2-1C, to Def Stan 61-12 (Part 6). Conductors : 0.5mm² tinned annealed copper wires to IEC 60228, (as far as applicable), class 5.
More informationWIRE & CABLE. 99 Wire Low fire hazard wire and cable
Applications 99 wire has a dual wall construction of radiation cross-linked modified polyester. This combines excellent mechanical performance and chemical resistance with a range of enhanced fire hazard
More informationENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 177 2012 Specification for Braided 75 Ω, Mini-Series Quad Shield Coaxial Cable for CMTS and SDI cables NOTICE
More informationContents. Category7 SSTP Solid Indoor Cable - Page 03
Product Catalog Contents Category7 SSTP Solid Indoor Cable - Page 03 Category6A UTP Solid Indoor Cable - Page 04 Category6A Keystone Jack - Page 05 Category6A Unshielded Patch Cord - Page 05 Category6
More informationSBCA Industry Standards Subcommittee. Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations
SBCA Industry Standards Subcommittee Document: SBCA Series 6 Recommended Practices Date of Issue: Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations
More informationCables for Data Transmission in Industrial Automation. Fieldbus Cables Copper Cables Fibre Optic Cables
Cables for Data Transmission in Industrial Automation Fieldbus Cables Copper Cables Fibre Optic Cables 2 KERPEN GmbH & Co. KG 2005 2.2006 Printing errors excepted. Subject to alteration. Contents Seite
More informationWire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits
Dual Wall 20ºC rated, Modified Polyester 99 wire has a dual wall construction of radiation crosslinked modified polyester. This combines excellent mechanical performance and chemical resistance with a
More informationCategory 6 UTP EuroClass C ca Cables
Category 6 UTP EuroClass C ca Cables Datasheet: GD103704v1 APPLICATION Brand-Rex Cat6Plus C6U cables exceed the Category 6 performance standards. They are rated to 250MHz and are suitable for use in all
More informationY-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking
Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking A Technical data Special PVC control cables, adapted to DINVDE0 part3 Temperature range flexing -5 C ) to +0 C fixed installation
More informationENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable
ENERGY (N)SHTOEU Low Voltage Reeling Cable Technical Data Type Type designation Approvals/standards Application (N)SHTOEU-J/-O DIN VDE 0250, Part 814; VDE-Reg.-Nr. 7519; GOST R Flexible reeling cable for
More informationElectrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.
734A COAXIAL CABLE Application Intended for interconnection of transmission and switching systems equipment. Features UL listed as NEC Type CMR and CSA certified as Type CMR. NORDX/CDT 734A coaxial was
More informationInstrumentation Cables
around a world of cables UL INSTRUMENTATION CABLES UL THHN CABLES UL THWN CABLES Instrumentation Cables INDEX Introduction Specialty Cables 300V & 00V Instrumentation Cable Types Certificates and Standards
More informationHO7RN-F 450/750V BS EN Highly Flexible Rubber Cable
Rubber Insulation and Rubber Sheathed Application Range Heavy duty flexible cables for medium mechanical stress For dry and wet applications Can be used for domestic electric tools According to HD 516
More informationCoaxial Cables Coax Serie. HF Steckverbinder für Mobilfunk-Anwendungen. in Bulk Rings or on Cable Drums
4.3-10 Coax Serie Coaxial Cables HF Steckverbinder für Mobilfunk-Anwendungen in Bulk Rings or on Cable Drums Coaxial Cables In addition to the wide range of coaxial connectors, Telegärtner offers suitable
More informationTPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT
TPE-INSULATED CABLES Products TPE - Cables TPE-INSULATED CABLES 105 C O N T E N T S C O N T E N T S Page TPE single cores according to DIN 72551, type A 107 TPE single cores according to DIN 72551, type
More informationCoaxial Cables. Coaxial Cables. & Addison.
Coaxial Cables Coaxial Cables & Addison www.caledonian-cables.co.uk www.caledonian-cables.net www.addison-cables.net www.addison-cables.com 1 Company Profile Coaxial Cabless. established in 1978.offers
More informationContent HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...
Content page ❿! Applications... /2 ❿! Construction examples of special cables... /3-6 ❿! S 670 PUR hybrid field bus control cable, suitable for cable tracks UL/CSA... /7 ❿! S 671 PVC hybrid field bus control
More informationC400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR
C400-UMUM-100 Product Classification Brand Product Series Product Type CNT Jumper with interface types UHF Male and UHF Male, 30.48 m CNT Braided cable assembly General Specifications Body Style, Connector
More informationRG58 Coaxial Cable: 2) Approval:
RG58 Coaxial Cable: Center Conductor:---------- 19X0.18mm Solid Copper/20 AWG Solid Copper Dielectric:--------------------2.95±0.05mm Solid PE Braid Coverage:-------------95%X16X6X0.127±0.005mm Tinned
More information- Characteristic impedance of cabling links is characterised by Return Loss
ISO/IEC 11801 ISO 11801 is the principle design standard for structured cabling systems for all countries of the world that do not have more specific standards, such as ISO 11801 (European Union), TIA
More informationLTE high-performance coaxial cables (RG replacement)
LTE high-performance coaxial cables (RG replacement) Center Conductor: See table below. Dielectric: LTE (extruded low-density PTFE) or low density / composite. Inner Shield: 875-892: None. 900-142: Flat
More informationTECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers)
TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED (SM 2~24 Fibers) Product: Single Mode Optical Fiber Cable Producer: XCOM LTD. / Bulgaira Date: August 1, 2012 Write by: Petar Georgiev
More informationCommunication, Control, and Industrial Cable
Communication, Control, and Industrial Cable Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 291 Get control of demanding applications T he broad
More informationFOR INTERCONNECT AND CROSS-CONNECT APPLICATIONS
FOR INTERCONNECT AND CROSS-CONNECT APPLICATIONS HIGH SPEED DS-3 & DS-4 CABLES Belden Your Widest Selection for Meeting DS-3 and DS-4 Network Requirements BELDEN, THE CABLE TECHNOLOGY LEADER IN HIGH-SPEED
More informationOFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS
OFFSHORE CABLES GENERAL CATALOGUE Offshore Cables technergy INTEGRATED CABLING SOLUTIONS TM 1 TEOF Offshore Cables INTEGRATED CABLING SOLUTIONS TM technergy Introduction Every offshore platform requires
More informationCables for data transmission in industrial automation
Cables for data transmission in industrial automation The Quality Connection The LEONI Group Cable expertise for the most various industrial markets. LEONI is a leading supplier of cable systems and related
More informationKerman & Kavian Cable Industries ( KCI )
KCI Kerman & Kavian Cable Industries ( KCI ) KCI Cables for control and instrumentation circuits 150/250 V (300 V) According to of IEC 60092-376 (2003) Electrical installations in ships - Part 376: Kerman
More informationCOMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationNew Product Bulletin. Belden Digital Audio Cable. Belden Brilliance AES/EBU
New Product Bulletin NP 267 Belden Digital Audio Cable Belden Brilliance AES/EBU Digital Audio Cable, Part No. 1353A, is a robust single-pair Cat 5e patch cord that utilizes Belden s exclusive Bonded-Pair
More informationWIRE&CABLE FILS&CÂBLES S I N C E
WIRE&CABLE FILS&CÂBLES 50 CELEBRATING 50+ YEARS S I N C E 1 9 6 0 Dear Friend: Thank you for choosing Provo Ltd. As the leader in providing Canadian industry, coast-to-coast with a full line of electronic
More informationABOUT US ABOUT US 1 CRANE CABLES
ABOUT US ABOUT US ÜNTEL KABLO, one of the leading cable manufacturers of Europe was established in 1972, Turkey. With almost 45 years of experience, it has been continuously developing and optimizing its
More informationEXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV
CABLE DESCRIPTION Single- or multi-phase electric cable for creating a weak external magnetic field,so as to obtain a cable wherein at last one of the conductors is assembled from two or more insulated
More informationDetailed Specifications & Technical Data
For more Information please call 1-800-Belden1 Description: Coax (2-1505A Type) 20 AWG BC, GIFPE isulation, Duofoil plus TC braid (95% cv.), PVC inner jackets. Pairs (4-9451 Type): 22 AWG TC, PP insul.,
More information* Peaks of 1.3mm MAX allowed only in a rate of 2% or less
COAXIAL CABLE 50 OHM LOW LOSS 956163-3 A C 800275 Rev: D. 08 October 2014 Rev: C Maximum MHz db/100m MHz db/100m 100 16.3 1000 56.5 200 23.5 1500 70.2 500 38.2 1800 77.2 800 49.5 2000 81.5 Diameter of
More informationPhoto: HELUKABEL. Motor, Servo & Feedback Cables D 1
Photo: HELUKABEL Motor, Servo & Feedback Cables D Motor, Servo & Feedback Cables A multitude of applications requires the construction of many special cables. Corresponding to the customers requirements,
More informationTransmission Media. Two main groups:
Transmission Media Two main groups: -Wire based media (hardwire, or guided), either : -electric, like twisted pair cable TP, coaxial cable -optic, like fiber optics -Wireless (softwire, or unguided), like
More informationMotor, Servo & Feedback Cables
Photo: HELUKABEL Motor, Servo & Feedback Cables D Motor, Servo & Feedback Cables A multitude of applications requires the construction of many special cables. Corresponding to the customers requirements,
More informationMedium Voltage Power Cables
N2XSY 6/0, /20, /30 NA2XSY 6/0, /20, /30 N2XS2Y 6/0, /20, /30 NA2XS2Y 6/0, /20, /30 N2XS(F)2Y 6/0, /20, /30 NA2XS(F)2Y 6/0, /20, /30 N2XSEY 3 x 6/0 Medium Voltage Power Cables Photo: HELUKABEL Q 47 Medium
More informationServo Cable Selection
Servo Cables Servo Cable Selection Chainflex cable Jacket Shield Class Bending radius moving (factor x d) Temperature moving from/to F ( C) Oil-resistant V max. ft/s (m/s) unsupported V max. ft/s (m/s)
More informationProduct information. Marine, Oil & Gas.
Product information Marine, Oil & Gas www.drakamog.com DRAKA Product information MOG 2010 Draka ShipLine range; the choice for reliability and flexibility For more than 100 years, Draka has met and exceeded
More informationCabling systems for LAN Office, LAN Home, LAN Industry, Access Networks, MAN, WAN and SAN. 10 GBit. ELine, MegaLine, FLine, GigaLine
COMPETENCE IN CABLE TECHNOLOGY ready for 0 GBit E t h e r n e t ELine, MegaLine, FLine, GigaLine Solutions@KERPEN Cabling systems for LAN Office, LAN Home, LAN Industry, Access Networks, MAN, WAN and SAN
More informationAmphenol Cable. Features Allows for mass termination Up to 64 conductors
G80.7mm Economical Flat Ribbon 94V-0 A G80 X X XX X FLAT RIBBON CABLE.7mm Up to 64 conductors VARIATION CODE Blank: Standard PACAGING LENGTH NUMBER OF CONDUCTORS : 500 Feet 09: 9 Position : 400 Feet 4:
More informationRAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø
RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø Automated Stacking Cranes (ASC) Ship To Shore Container Cranes (STS) Rubber Tyre Gantry (RTG)
More informationConnection technology for wireless communication systems
Connection technology for wireless communication systems Rosenberger Rosenberger, founded in 1958, is a family owned company and ranks today among the top global manufacturers of high-frequency coaxial
More informationThe Quality Connection. Flex Flexible Control Cable
The Quality Connection ible Control Cable 2 Introduction Introduction 3 The LEONI Group Concentrated competence in cables The Business Unit Industrial Projects Our products have maximum quality in coon
More informationNexans Industrial Solutions PRODUCT CATALOG
Nexans Industrial Solutions PRODUCT CATALOG i NEXANS BRINGS ENERGY TO LIFE COPPER CABLES Nexans brings energy to life through an extensive range of cables and cabling solutions that deliver increased performance
More informationStandard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables
Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES ( Data Sheets ) 11 kv XLPE-Insulated Three-Core Underground Cables (3x240 mm 2 ) ADWEA/ADDC/AADC STANDARD : D-AAA-CAB-11-3Cx240
More informationEXCELLENT ELECTRICAL PERFORMANCES
50OHMS CORRUGATED COPPER TUBE COAXIAL CABLE PRODUCT INTRODUCTION 2 Hansen's manufacturing of wide-scope 50ohms corrugated copper coaxial Cable is the fruitful result of the engineers' diligent research
More informationFireproof Cables (Fire Resistant LSOH Sheathed Cables) КИФнг(A)-HF for RS485
Content Page Certificates 3 Industrial Cables Production 4-5 Industrial Cables of PJSC «Odeskabel» 6 КИФ-В for RS485 (CAN) КИФ-В 1х2х0,6; КИФ-В 1,5х2х0,6; КИФ-В 2х2х0,6; КИФ-В 3х,2х0,6; КИФ-В 4х2х0,6 8
More informationINDUSTRIAL DATA LAND. The best solution for the industrial automation.
The best solution for the industrial automation www.ceamcavi.it There is a quality, in CEAM s production, that goes beyond the features of each single cable, a value which involves all the company processes
More informationECOFLEX 10 Characteristics Diameter 10,2 mm. ECOFLEX 15 Characteristics Diameter 14,6 mm. AIRCOM PLUS Characteristics Diameter 10,3 mm
AIRCOM PLUS Characteristics Diameter 10,3 mm Attenuation @ 1 GHz/100m 13,4 db Attenuation @ 1 GHz/100ft 4,08 db 10 GHz ECOFLEX 10 Characteristics Diameter 10,2 mm Attenuation @ 1 GHz/100m 14,2 db Attenuation
More informationCABLE.
CABLE www.pcnet-cable.com.tw sales@pcnet-cable.com.tw PCnet Leading Your Net! PCnet was founded in 1985 and is a leading manufacturer of netwking industries. We provide a complete range of products f structured
More informationCY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED
PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED ISSUE DATE: 04/02/2016 PAGE: 1 Manufactured generally to BS EN 50525-2-11 Plain Annealed Flexible Copper Conductors / PVC Insulated / Tinned
More informationOptical Systems Contents
Optical Systems Optical Systems Contents Distribution Cables C Type Page 3.7 Breakout Cables T Type Page 3.9 Loose Tube Cables Unitube Page 3.14 Multi Loose Tube Page 3.18 Optical Components Pig / Patch
More informationH155A02. Product Description. Product Specifications. Technical Specifications. Application. Bend Radius. CCB-Sub-Crush Resistance.
H155A02 Part Number: H155A02 COAX RF H155 FRNC Product Description COAX RF H155 FRNC Product Specifications Application Application 1: Application 2: 50 Ohm low loss coaxial transmission cable designed
More informationSAC-5P- 1,5-PUR/M12FS SH
Extract from the online catalog SAC-5P- 1,5-PUR/M12FS SH Order No.: 1682935 Sensor/Actuator cable, 5-position, PUR, halogen-free, Black-gray RAL 7021, shielded, Free conductor end M12, on Socket, straight
More informationTo keep your family safe and protected V-Guard Wires & Cables
The Suraksha Chakra To keep your family safe and protected V-Guard Wires & Cables Efficient Performance For over four decades V-Guard lived up to the reputation of making reliable products that were designed
More informationCABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES
CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES FOR CABLE CARRIERS EDITION 09-2012 Durable, reliable, cost-effective
More informationCable Type 125. CAI Certification Specification
Cable Type 125 CAI Certification Specification Ref: CAI-008-C / 125 / 12-2016 Confederation of Aerial Industries Ltd Communications House 41a Market Street WATFORD Herts WD18 0PN Tel: 01923 803030 Fax:
More informationScreened servo cable with PUR outer sheath for highly dynamic power chain application - certified
Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified - Screened servo cable for high dynamic power chain application in harsh conditions with UL/CSA AWM and
More informationVFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS
VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS INDUSTRIAL VFD CABLES Index n Variable Frequency Drive (VFD) Power Cables Extra Flexible VFD Power Cable............... 2-3 Crush & Impact Resistant
More informationJumper cable. Feeder cable + connector. Cable clamp. Grounding kit
Mobile Networks 1 Jumper cable Feeder cable + connector Cable clamp Grounding kit 2 28 Superflexible and Extraflexible Cables Draka superflexible RFF cables and extraflexible RFE cables offer the most
More informationDetailed Specifications & Technical Data
RFP Specification #17-11125-C, Exhibit 2 Programmable Light Poles for BART Plaza ENGLISH MEASUREMENT VERSION 1502SB Multi-Conductor - Multimedia Control Cable For more Information please call 1-800-Belden1
More information