Cabling systems for LAN Office, LAN Home, LAN Industry, Access Networks, MAN, WAN and SAN. 10 GBit. ELine, MegaLine, FLine, GigaLine

Size: px
Start display at page:

Download "Cabling systems for LAN Office, LAN Home, LAN Industry, Access Networks, MAN, WAN and SAN. 10 GBit. ELine, MegaLine, FLine, GigaLine"

Transcription

1 COMPETENCE IN CABLE TECHNOLOGY ready for 0 GBit E t h e r n e t ELine, MegaLine, FLine, GigaLine Solutions@KERPEN Cabling systems for LAN Office, LAN Home, LAN Industry, Access Networks, MAN, WAN and SAN

2 KERPEN Who are we? For more than 80 years now, KERPEN as one of the leading companies in the cable industry has been successfully meeting the complex demands of international markets. The company now employs more than 700 people. A central element of the KERPEN philosophy is the quest for constant improvement feet firmly planted in the past and head in the world of the future! And it is to the future that we look, producing high-quality, innovative cable and cabling products which are always one step ahead of the standards of the time. As a competent developer and manufacturer of cables and cabling systems, we now supply the high-end market segment in information technology and industry LAN Office, LAN Industry, city networks/telecom and LAN Home. The common denominator of Ethernet and Internet Protocol (IP) are integrating and changing the world of telecommunications. KERPEN has the necessary passive system solutions in the form of copper data cables and fibre optic cables. MegaLine copper data cables and ELine systems engineering are used to build up high-performance systems for structured indoor cabling. When broadband data transfer over long distances in LANs and city networks is required, GigaLine fibre optic cables with the new improved Gigabit Ethernet quality and KERPEN FLine systems engineering are now the solution of choice. For the purposes of industry and the international project business in plant engineering, KERPEN provides high-quality cables for measurement and control engineering which comply fully with national and international standards. Kerpen can also provide cables to factory specifications and custom-made according to the specific wishes of our customers. The development and production of compounds for the cable and plastics industry rounds off our varied product portfolio. KERPEN with its committed, creative and competent employees is at home in the markets of the world, by way of branches and sales offices or via representatives. Quality is, and always will be, the KERPEN yardstick. This is documented by the quality management system DIN EN ISO 900 certified in 990. Since 998, KERPEN has also been certified according to the environmental management system DIN ISO 00.

3 Contents Introduction Page Market segments and applications Page 6 Copper Solutions MegaLine Data Cables MegaLine Space Page 8 MegaLine G-0 S/F Page 8 MegaLine F0-0 S/F Page 0 MegaLine F0-0 S/F Page MegaLine F6-90 S/F Page MegaLine F6-80 S/F Page 6 MegaLine E-70 S/F Page 8 MegaLine E-70 F/F Page 0 MegaLine E- U/F Page MegaLine E-0 F/U Page MegaLine E-0 U/U Page 6 MegaLine D-0 SF/U Page 8 MegaLine D-0 F/U Page 0 MegaLine D-0 U/U Page MegaLine F0-0 S/F flex Page MegaLine F6-90 S/F flex Page 6 MegaLine E-70 S/F flex Page 8 MegaLine E- U/F flex Page 0 MegaLine E-0 U/U flex Page MegaLine D-0 SF/U flex Page MegaLine D-0 F/U flex Page 6 MegaLine Contents ELine Systems Engineering ELine PREMIUM system Page 8 ELine 00 EC7 Page 60 ELine 00 RJ S Page 6 ELine 0 RJ Page 66 Products Page 68 Accessories Page 70 Floorboxes Page 79 ELine NOVUM system Page 80 ELine 600 GG Page 8 ELine 0 MLS/MLU Page 86 Products Page 87 Accessories Page 88 ELine FIXUM system Page 9 Acceptance testing Page 9 ELine GigaLine FLine

4 Fibre Optic Solutions GigaLine Data Cables GigaLine Page 98 GigaLine FO indoor cables Page 00 GigaLine FO universal cables Page 0 GigaLine FO outdoor cables Page 06 GigaLine abbreviations Page 0 GigaLine fibre qualities Page GigaLine colour codes Page FLine Systems Engineering FLine system overview Page GigaLine ready-made Page 9 FLine housings Page 8 FLine Hybrid Page 8 FLine compact Page 0 FLine office and floor distributors Page FLine outlets Page 8 FLine floorbox solutions Page Services in the Internet Page Specifications and tender texts Planning documents Certificates Link Matrix Warranty programme References Technical articles Certification programme KERPEN Trained Networker Seminars and roadshows Up-to-date information/standardisation

5 competence and performance all from one supplier High-quality universal cables and optimised high-performance cabling systems KERPEN offers you economical solutions for an infrastructure designed to meet the demands of the future in the fields LAN Office, LAN Industry, LAN Home, Access, MAN, WAN and SAN. Why not profit from our know-how as one of the leading developers and suppliers on the European cable market? You can rely on tried and tested high-quality products, matching components and comprehensive services with regard to counselling and support for your projects! Let us help you to implement the optimum solution for your network! This catalogue at a glance shows our entire range of products and services in the field of IT cabling. Copper solutions high-performance cables and systems for LAN Office, LAN Industry and LAN Home Universal high-performance MegaLine copper data cables and innovative ELine systems engineering from KERPEN give you high-performance copper solutions for all categories and classes. With the new MegaLine SPACE types, KERPEN has yet again raised the standards for copper data cables. Fibre optic solutions high-performance cables and systems for LAN, Access, MAN, WAN and SAN GigaLine fibre optic cables and FLine systems engineering are used to build up high-speed fibre optic cabling systems designed to meet the demands of the future on all network levels. GigaLine fibre optic cables with optimised multimode and single-mode fibres allow the implementation of powerful and economical solutions. Added value helpful tools for your planning Besides detailed information on our range of products, this catalogue provides you with important supplementary information on the standards situation and on technical trends and developments. We also assist you in your detailed planning via Specifications and tender texts on CD Planner tools under kerpen.com Your own personal contacts Competence, efficiency, advice why not talk with us? We support your project and help you to bring it to a successful finish. Here's what you can expect from us as your partner: We offer project support and advice from our competent employees on location if required We provide you with supportive information on the standards situation and demonstrate their interpretation, application and consequences We prepare tender texts and send them to you so you can integrate them into your technical specifications We advise you in detail and support you in the use of all products to help you to develop arguments for using KERPEN products Without any obligation on your part, we reserve the quantities you require for your projects We offer you training and support We won't be satisfied until you are! Introduction

6 Market segments and applications LAN Office The scalability of Ethernet technology allows the constant expansion of the networks used for information engineering in buildings. In banks and insurance companies, research and development, universities, hospitals, hotels, airports and many other fields of application, high-performance, highly available Ethernet networks are indispensable for smooth operation and economic success. Besides the economically sound networking of PCs and printers, the intelligent combination of fibre optic technology in the backbone and copper technology up to the user allows IP telephony too. In addition, Power over Ethernet supplies terminal equipment such as WEB cameras, WLAN access points, IP telephones and notebooks with electricity and voltage all via the structured copper cabling! LAN Home Whereas the LAN Office field focuses on the networking of printers and PCs, multimedia applications are the centre of interest in the LAN Home segment. Service-independent broadband multimedia cablings provide the platform for combining information and communication engineering at the home workplace with the range of entertainment offered in the leisure field. There are now an increasing number of components with network capabilities which can turn your PC into a television set, your television set into an Internet access point with a playstation and your stereo system into a storage medium for MP files. 6

7 LAN Industry LAN Industry has become successfully established as a communication medium in industrial automation. The technology is now used on all levels for the networking of controls, drives, PCs and remote I/Os. Ethernet offers the advantage of a sophisticated, standardised technology as well as great potential for rationalisation: The worldwide IT standard Consistent communication to office computer technology Standardised protocols for data communication and web functions Scalable Transparent communication between all network participants Simplified programming, taking into operation and servicing This and a large number of other advantages make Ethernet an interesting proposition for use in industrial automation. No matter whether the projects involved are in the field of manufacture, process or building automation, Ethernet is the technology for all applications. MAN/WAN The networking of the individual branches of a company within a city is usually achieved via a public MAN (Metropolitan Area Network). The introduction of the 0 GbE standard provided a reasonably priced alternative to the classical telecommunication standards. Ethernet also provides alternatives in the field of long-distance communications. Thus, standard singlemode fibres allow rapid WANs (Wide Area Networks) to be operated over distances of up to 0 km without additional active components. LAN/MAN/WAN/SAN However, Ethernet technology has become a part of WANs for lower data rates too: Deutsche Telekom gives its customers the opportunity to interconnect Local Area Networks (LANs) via Ethernet WANs at different locations. The bandwidth provided starts at 0 MBit/s and can be increased to up to 00 MBit/s depending on the requirements. SAN Large companies also often have extensive Storage Area Networks (SANs) whose high demands can also be met using 0 Gigabit Ethernet. Besides price and performance, the general serviceability of the company network often plays a major role here. Conclusion: Ethernet technology now offers the information technology platform for virtually all market segments, in particular via the rapid Gigabit and 0 Gigabit Ethernet protocols. KERPEN also offers the necessary high-performance cabling solutions designed to meet the demands of the future. 7

8 MegaLine Introduction In addition to numerous discoveries and achievement, the last thousend years have brought us the still young age of information. Now we are experiencing a veritable information explosion. Whereas humanity required about 0,000 years to double its knowledge, Robert Anton Wilson tells us that this is now happening every two years. Since the invention of the Internet, this knowledge has been available everywhere around the clock. Worldwide networking makes this possible. Knowledge transfer thus no longer takes place in the form of analog voice transmission via the 00-year-old telephone network but preferably as digital data, image or voice transmission. The information quantity is not measured in printed A pages now but in bits and bytes. In the course of 0 years, the transmission performance of networks designed to meet the demands of the future has increased by the incredible factor of 0,000 and there is no end in sight. Demands made on availability Susceptibility to interference Data rates Prices Did you know that a file size of up to 8 Mbytes is required for a PowerPoint presentation? And that digital photographs occupy memory space of 8 Mbytes? Quality of the installations/ planning/ concepts Incredible but true: an uncompressed HDTV film with a length of two hours swallows up. Tbytes! The demands made on network processors and the system periphery are rising considerably in step with the rapid increase in file size. The prospective development of high-performance network technologies takes this fact into consideration. As far back as 990, the network industry allowed the transmission of 0 Mbit/s up to the user, thus replacing the techniques used in the first phase. Five years later, performance at the workplace had been multiplied by 0 to reach 00 Mbit/s. Since the year 000, Gigabit Ethernet has been on the increase. A new era will be rung in with the introduction of 0 Gigabit Ethernet in 006. However, rising data rates, increased demands made on availability and growing susceptibility to interference on the one hand against price drops and the associated reduction in the quality of the planning and implementation of network installations on the other are now the cause of increasingly frequent network failure or reduced network performance. According to a survey carried out by well-known experts, % of faults are due to unsuitable installations and % are a result of insufficient planning. In 8 % of cases, faulty or insufficiently dimensioned cabling components were the cause of network problems. If you consider that, measured against an expected service life of 0 to years for the cabling required for information technology, the costs only make up % of the total network costs, minimum budgets for the cabling often turn out to be bad investments. Sometimes the follow-up costs are several times the amount spent on the initial installation. 8

9 The SPACE concept With its new SPACE concept, KERPEN offers the market and its customers a decision-making matrix for finding the correct data cable in a pragmatic, structured way. The SPACE concept is based on the classification of the main selection criteria for determining the potential overall performance of a data cable. Performance EMC Security Application Construction The demands made on the segment in question rise in step with the increase in the SPACE index. For example, the cable marked in yellow is a data cable with the SPACE code! This means that the data cable in question passes the fire test according to IEC 60-- (Security Level ), meets the minimum requirements of the new Class F A (Performance Level ) and is dimensioned for applications with more than 0 GbE (Application Level ). It consists of a conductor with AWG (Construction Level ) and thus has low attenuation values and an increased current-handling capacity. The noise suppression totals > 80 db (EMC Level ). After SPACE classification, the appropriately structured MegaLine specifications allow the elaboration of further unique technical features such as the safety reserves of the electrical characteristics in comparison to the minimum requirements of the standard and the freedom from heavy metals according to RoHS. SPACE The SPACE concept also allows the value for money to be assessed and creates space for alternative technical and economical scenarios. With the VDE kitemark (an independent hallmark of quality including production monitoring), KERPEN documents that it guarantees the SPACE quality features at all times. SPACE Matrix Performance Construction Security (Fire behaviour) (Cabling class, Application S P bandwidth) A C (Ethernet, TV) (Conductor dimensions, tensile strength) E EMC (Coupling losses) IEC 60-- > Class E > 0 MHz > 00 MbE AWG 7 > 0 db IEC-60-- > Class E A > 00 MHz > GbE AWG 6/ > 0 db IEC-60-- > Class F > 600 MHz bis 0 GbE AWG > 60 db EFP Grade > Class F A >,000 MHz > 0 GbE AWG > 70 db EFP Grade > Class G >,00 MHz > 0 GbE TV AWG > 80 db 9

10 MegaLine S:SECURITY Fire behaviour As a result of the constant increase in the installed basis and the installation density, the fire behaviour of data cables is an important safety criterion for avoiding fire damage to persons and material assets. In themselves, data cables are safe resources. When manufactured according to the legal regulations and installed correctly, they cannot cause a fire. Like all objects made of plastic, however, if cables catch fire, they can ignite and spread the fire. The aim is to prevent or minimise the spreading of fire and the consequential damage it causes. This is achieved via flameresistant, halogen-free cable designs. MegaLine data cables have improved fire protection characteristics: The extremely low smoke development according to IEC 60 makes rescue and salvage operations easier The low toxicity (dioxins are not produced) means that the risk of poisoning is reduced As a result of the freedom from halogens according to IEC 607-, there is no consequential damage to material assets as a result of corrosion The low fire load values limit the exacerbating effects on the source of the fire The high oxygen index (0I up to ) reduces the flammability The KERPEN SPACE concept offers five different security levels with regard to the fire propagation / flame retardance: S : IEC 60--: Testing of the vertical flame propagation in a core or individual cable. Test method: incandescent flame. S : IEC 60--: Testing of the vertical flame propagation in a core or individual cable. Test procedure: KW flame. A flame is applied to the lower end of a vertical sample of the cable with a length of approx. 60 cm for about 60 seconds using a type of Bunsen burner. After removal of the burner, the flames must go out by themselves. The parts of the cable damaged by the flames must not reach its upper end (distance: 0 mm). S : IEC 60--: Testing of the flame propagation in an arrangement of several cables, a so-called cable bundle, is carried out according to IEC In this cable bundle test, a flame is applied to the lower part of the test samples on a vertical ladder with a length of 60 cm using a high-performance burner. During and after intensive application of the flame for a test period of 0 minutes, the cables must not burn higher than 0 cm. S : EFP (Enhanced Fire Performance) Grade In this cable bundle test, a flame is applied to the lower part of the test samples on a vertical ladder with a length of 60 cm using a high-performance burner. During and after intensive application of the flame for a test period of 0 minutes, only about m of the section to which the flame is applied must burn. Immediately after removal of the flame, the self-extinguishing process must start. Only specially designed data cables can stand up to this exacting fire test. S : EFP (Enhanced Fire Performance) Grade This stricter safety level is application-specific. Safety levels S to S are used in particular where high and very high safety measures are required for the protection of persons (in hospitals, schools, hotels, airports, stations, department stores etc.) or material assets (in power stations, computer centres, banks and insurance companies, alarm systems etc.). 0

11 P:PERFORMANCE Cabling class/bandwidth SPACE Indoor cablings are expected to have a service life of 0 to years. This requires far-sighted planning of the necessary performance of cabling systems and their components. The international standards have often not gone far enough due to the compromises struggled for and in view of the swiftly increasing transmission rates. Since the development of 0 Gigabit Ethernet, none of the cabling classes below Class F can be said to meet the demands of the future. P : better than Class E A (00 MHz) MHz E-70 F/F E-70 S/F Class EA MegaLine For example MegaLine E-70 S/F: better than Category 6 according to EN 088 and IEC 66 very good NEXT, very good shield characteristics (shielding of pairs and overall shielding), low SKEW P : better than Class F (600 MHz) Hard work is currently being done to standardise new classes in order to meet to the demands of the future. With the MegaLine SPACE concept, KERPEN provides five different performance classes to choose from. Each of them in itself has very high reserves with regard to the standard involved. P : better than Class F (0 MHz) MHz E-0 U/U E-0 F/U E- U/F Class E MegaLine MHz,00, F6-80 S/F F6-90 S/F Class F MegaLine For example MegaLine F6-90 S/F: better than Category 7 according to EN 088 and IEC 66 excellent NEXT, excellent shield characteristics (shielding of pairs and overall shielding), low SKEW For example MegaLine E- U/F: better than Category 6 according to EN 088 and IEC 66 very good NEXT, low SKEW

12 MegaLine P : better than Class F A (,000 MHz) MHz,0,00,0,00,00, F0-0 S/F F0-0 S/F Class FA MegaLine For example MegaLine F0-0 S/F: better than Category 7 according to EN 088 and IEC 66 excellent NEXT, low attenuation, excellent shield characteristics (shielding of pairs and overall shielding), low SKEW P : better than Class G (,00 MHz) MHz,600,00,00, G-0 S/F Class G MegaLine MegaLine G-0 S/F is better than Category 7 ( 8 ) according to EN 088 and IEC 66 excellent NEXT, excellent shield characteristics (shielding of pairs and overall shielding), low SKEW MegaLine data cables have excellent transmission performance. They offer high safety reserves and are always one step ahead of the standard. MegaLine : an investment with a future!

13 A:APPLICATION Ethernet/TV SPACE MegaLine data cables are real all-rounders. Their excellent performance, their total universal capabilities and their convincing economic efficiency make them an unbeatable transmission medium for the last mile. No other transmission medium has as many advantages when the aim is to network communication and information facilities in an economical way which meets the demands of the future. The large safety reserves mean that multimedia applications like TV or transmission protocols with high bandwidth requirements such as 0 Gigabit Ethernet and 8 Gigabit Fiberchannel can be transmitted over 00 m. Experts have calculated that, as far as we know today, MegaLine Category 7 data cables allow transmission distances of as much as 6 Gbit/s. The use of low-loss broadband S/FTP cables with individual or overall shield in conjunction with multimedia cabling systems such as ELine 00 EC7 allows socalled cable or duty sharing. Cables and connectors form a perfect symbiosis: pairs, connecting clips: each with GHz performance. This allows the parallel, simultaneous use of different applications via one cable and one connector: data, voice and images. Ultimately, this multimedia system does not need to cost more than conventional systems, in which an individual cable and an individual connector is usually required for each service. This allows savings of up to 0 % of the necessary cables, connectors, outlets and patch panels. Multiple use reduces the system costs by 0 % (depending on the services used). The reduction of the cables and outlets actually required usually also allows reductions in the costs for cable channels, switching cabinets etc. But MegaLine data cables are capable of more. The supply of current (up to 0 ma) and voltage (up to 8 V) can be provided via PoE (according to IEEE 80.af). The current is fed in centrally via the floor distributor or switch. Devices such as IP telephones, Web cameras, WLAN access points etc. are supplied via the telecommunications outlet. The voltage is tapped via a phantom circuit or two unassigned pairs. KERPEN provides five different application levels with the MegaLine SPACE concept. Systematic multimedia PC Telephone Video/audio/TV/radio A : up to 00 Mbit/s (Fast Ethernet) IEEE 80. u A : up to,000 Mbit/s (Gigabit Ethernet) IEEE 80. ab A : up to 0,000 Mbit/s (0 Gigabit Ethernet) IEEE 80. an (draft) A : over 0,000 Mbit/s (0 Gigabit Ethernet) IEEE 80. an (draft) A : over 0,000 Mbit/s (0 Gigabit Ethernet) and TV IEEE 80. an (draft) and multimedia MegaLine data cables have a convincingly wide range of applications and are unbeatable value for money.

14 MegaLine C:CONSTRUCTION Conductor dimensions The demands made on data cables designed to meet the demands of the future are varied and at times contradictory. MegaLine data cables of all categories and classes combine high-performance, universal capabilities and economic efficiency. This standard of quality can only be achieved via an integrated cable design. KERPEN first put MegaLine data cables in -pair S/FTP design (00 Ohm) on the market in the early 90s. This KERPEN innovation has been constantly optimised and adapted to the requirements of the market ever since. High-precision conductor and core geometries, optimally matched lay lengths in the pairs and the use of very high-quality insulation and sheath materials are the characteristic features of MegaLine data cables. C : AWG 7 (7x0. mm/0. mm ) Tensile stress: 0/0 N (P/P) maximum Conductor resistance: 6 ohm/km maximum C : AWG 6 / AWG C : AWG 6 (7x0.6 mm/0. mm ) Tensile stress: 60/0 N (P/P) maximum Conductor resistance: ohm/km maximum C : AWG (7x0.8 mm/0.7 mm ) Tensile stress: 70/ N (P/P) maximum Conductor resistance: 0.6 ohm/km maximum C : AWG (0. mm/0.0 mm ) MegaLine data cables are produced on ultra-modern equipment. As a result of procedural innovations, the machinery used corresponds with the state of the art in the data cable industry. The use of physical foaming in the manufacture of high-frequency cores allows excellent, uniform electrical and geometrical characteristics to be achieved. Double skin layers ensure excellent mechanical stability. Patented stranding techniques show that, from a technical point of view, KERPEN takes the lead in the data cable industry. Tensile stress: 90/ N (P/P) maximum Conductor resistance: 86.8 ohm/km maximum C : AWG (0.7 mm/0.8 mm ) Tensile stress: 0/ N (P/P) maximum Conductor resistance: 68.9 ohm/km maximum C : AWG (0.6 mm/0. mm ) Tensile stress: 0/6 N (P/P) maximum Conductor resistance:.7 ohm/km maximum MegaLine data cables have low external diameters, thus allowing high packing densities and small bending radii. The weight savings and the robust cable structure are beneficial in assembly and installation, even under difficult conditions. MegaLine data cables can be recognized by their unmistakable Ethernet yellow. But there's only KERPEN inside if it says so on the outside! With the MegaLine SPACE concept, KERPEN divides the MegaLine range into five different conductor classes. The conductor classes describe the permitted tensile stress during installation and the conductor resistance. The current-handling capacity for a maximum environmental temperature of 60 C and the maximum installation lengths in the transmission channel can be derived from this on request.

15 E:EMC Coupling attenuation SPACE The electromagnetic compatibility (EMC) is the ability of devices, systems and plants to function satisfactorily in an electromagnetic environment without negative effects on other devices, systems or plants. EMC legislation prescribes the electromagnetic compatibility of devices, systems and plants. The limits for the emission of interference and the immunity to interference which must be observed are regulated in EN 0 (Class B) and EN 008-/ / EN 0. The purpose of a data cable is to resist electromagnetic influences coming from the outside to the inside (immunity to interference) and from the inside to the outside (emission of interference). The susceptibility of data cable systems to interference increases in step with the transmission frequency and the data rates (currently 0 Gigabit Ethernet). The main danger is increasingly a result of the Alien Crosstalk between adjacent data cables. Depending on their structure, data cables have different capabilities with regard to the prevention or reduction of interference. Unshielded data cables have very good symmetry characteristics but are not shielded against internal, external or adjacent sources of interference. They are endangered to a high degree by the environment of the installation. Data cables with individual or overall shield have very good symmetry characteristics and good or even very good shield characteristics. The EMC is very good or even excellent. Interference coming from the environment of the installation (adjacent data cables) can be ruled out completely. With the MegaLine SPACE concept, KERPEN provides five different EMC levels to choose from. The evaluation criteria are the coupling attenuation (interference power suppression). As the sum of the shield attenuation and the symmetry attenuation, the coupling attenuation are the be-all and end-all for the assessment and comparison of the overall EMC behaviour of data cables with various different structures. MegaLine data cables with a dual shield reach values of > 80 db up to,000 MHz, thus suppressing incoming or outgoing potential interference by a factor of > 0,000. E : Coupling attenuation > 0 db Interference suppression exceeding a factor of 00 E : Coupling attenuation > 0 db Interference suppression exceeding a factor of 00 E : Coupling attenuation > 60 db Interference suppression exceeding a factor of,000 E : Coupling attenuation > 70 db Interference suppression exceeding a factor of,000 E : Coupling attenuation > 80 db Interference suppression exceeding a factor of 0,000 MegaLine S/FTP data cables with overall shield and individually shielded S/FTP data cables have an excellent EMC, making them an obvious choice for the fail-safe transmission of high data rates such as those offered by 0 Gigabit Ethernet etc. Electromagnetic compatibility Structure U/UTP F/UTP S/FTP Symmetry characteristics Shield characteristics./ Influence of the installation environment./.

16 MegaLine Nomenclature There are a large number of different type designations. The standardisation defined in ISO/IEC 80 nd Edition determines the elements of the design in an unambiguous way: xx/xxx Balanced element TP Individual shield U F = Unshielded = Foil shield Cable types S/FTP F/FTP Overall shield F = Foil shield S = Copper braid shield SF = Cooper braid and foil shield U/FTP Examples: SF/UTP = Cable with overall copper braid and foil shield with unshielded individual elements. S/FTP = Cable with overall copper braid shield and individual elements with foil shield. Letter for cabling class Bandwidth acc. to standard (factor 00) Bandwidth MegaLine (factor 0) G = Class G F = Class F E = Class E D = Class D =,00 MHz 0 =,000 MHz 6 = 600 MHz = 00 MHz = 0 MHz = 00 MHz 0 =,00 MHz 0 =,00 MHz 0 =,00 MHz 90 = 900 MHz 8 = 800 MHz 70 = 700 MHz = 0 MHz 0 = 00 MHz 0 = 00 MHz 6

17 SPACE SF/UTP F/UTP With the SPACE concept, KERPEN has introduced a new nomenclature for Megaline. This makes it easier to assign cables to the old and new cabling classes and the corresponding categories. The new nomenclature also includes the indication of the bandwidth of MegaLine in comparison to the standard. This allows you to make the perfect choice at a glance. The new nomenclature is rounded off by information on design according to the international standard and the material used for the sheath. Example: U/UTP MegaLine F0-0 S/F H: data cable according to new cabling class F A (,000 MHz) with a bandwidth of,00 MHz in S/FTP design and with a halogen-free outer sheath. Design TP (Twisted Pair) Sheath H = Halogen-free, flame-retardant Y = PVC Y = PE Y = PUR S/F = Overall shield (copper braid)/individual shield (foil) F/F = Overall shield (foil)/individual shield (foil) U/F = Unshielded/individual shield (foil) SF/U = Overall shield (copper braid & foil)/unshielded F/U = Overall shield (foil)/unshielded U/U = Unshielded/unshielded 7

18 8MegaLine MegaLine G-0 S/F S P A C E Type: KS-0YSCH xxawg / PIMF Construction: Conductor: bare copper wire, AWG / Insulation: cellular-pe, core-ø: nominal value.6 mm Twisting element: Pair Individual screen: aluminium bonded polyester tape Twisting: pairs Overall screen: tinned copper wire braid Outer sheath: halogen-free, flame retardend compound Printing outer sheath: KERPEN MegaLine G-0 S/F P H SPACE CODE VDE approval mark Production lot code Meter marking Fire behaviour: Flame retardance: acc. to IEC 60-- Halogen acid gas emission: acc. to IEC 607- Smoke density: acc. to IEC 60 Calorific value (MJ/m): 0.7 (approx.) Performance: Better than category 7 ( 8 ) acc. EN 088 and IEC 66 excellent NEXT, very low attenuation, excellent screening characteristics (individual and overall screen), low SKEW Bandwidth,00 MHz Applications: Installation cable for generic cabling systems acc. ISO/IEC 80 and EN 07 (. edition) and for residential cabling and SOHO acc. ISO/IEC 08 and EN 07- (draft). Ideal for all applications of classes D up to F A Multimedia (TV, Video, Data, Voice) >0 GbE acc. IEEE 80. an (draft), Cable sharing, VoIP, PoE Mechanical characteristics: Bending radius: during installation: 8 x overall diameter (min.) after installation: x overall diameter (min.) Tensile strength: 0 (max.) Crush (N/00mm):,000 Impact (number of shocks): 0 Electromagnetic behaviour: Transfer impedance at 0 MHz (mohm/m): (nominal value) Screening attenuation up to,000 MHz (db): 80 (nominal value) Coupling attenuation up to,000 MHz (db): 90 (nominal value) S Colour code: wh/bu, wh/or, wh/gn, wh/bn Colour outer sheath: yellow, RAL 0 Security (Fire behaviour) P IEC > class E > 0 MHz Conductor Insulation Individual screen Overall screen Outer sheath IEC > class E A > 00 MHz Performance (Cabling class, bandwidth) A > 00 MbE > GbE Application (Ethernet, TV) C AWG 7 AWG 6/ Construction (Conductor size, Tensile strength) E > 0 db > 0 db EMC (Coupling attenuation) IEC > class F > 600 MHz up to 0 GbE AWG > 60 db EFP Grade > class F A >,000 MHz > 0 GbE AWG > 70 db EFP Grade > class G >,00 MHz > 0 GbE TV AWG > 80 db

19 Electrical characteristics at 0 C: DC resistance (Ohm/km): 7. (max.) Insulation resistance (Gohm x km): (min.) Mutual capacitance (pf/m): (approx.) Transfer capacitance (e) (pf/km):,00 (approx.) Signal velocity (c): 0.8 (approx.) Propagation delay (ns/00m): 0 (approx.) Skew at 00 MHz (ns/00m): (approx.) Characteristic impedance at 00 MHz (Ohm): 00 ± Test voltage Ueff (V):,000 Operating voltage Ueff (V): (max.) Frequency Attenuation NEXT PS-NEXT ACR PS-ACR EL-FEXT PS-ELFEXT RL MHz db/00m db db db@00m db@00m db@00m db@00m db typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 max.* min.* min.* min.* min.* min.* min.* min.* , , , , , * EN 088--/IEC 66- PS-A-NEXT@00m f/mhz PS-A-NEXT/dB P P P P Class E Class F MegaLine G-0 S/F Chemical characteristics: Free of hazardous substances acc. to RoHS 00/9/EG Certificates and Approvals: Quality mark with production control: VDE Link performance: KERPEN ELine systems and further commercial cabling systems Inspection certificate: acc. to DIN respectively EN 00 In agreement to LVD (7//EEC): Thermal characteristics: Temperature range for fixed installation -0 C up to + 60 C Temperature range for mobile operation 0 C up to + 0 C Article number Size Overall diameter Weight Copper number Colour sheat mm kg/km kg/km 7KS8000 P 8.6 (approx.) 80 (approx.) 8 yellow, RAL 0 Package: Drum,000 m 9

20 MegaLine MegaLine F0-0 S/F S P A C E Type: KS-0YSCH xxawg / PIMF Type: KS-0YSCH x (xxawg / PIMF) Construction: Conductor: bare copper wire, AWG / Insulation: cellular-pe, core-ø: nominal value.6 mm Twisting element: Pair Individual screen: aluminium bonded polyester tape Twisting: pairs Overall screen: tinned copper wire braid Outer sheath: halogen-free, flame retardend compound Conductor Insulation Individual screen Overall screen Outer sheath Printing outer sheath: KERPEN MegaLine F0-0 S/F P H SPACE CODE VDE approval markk Production lot code Meter marking Colour code: wh/bu, wh/or, wh/gn, wh/bn Colour outer sheath: yellow, RAL 0 Fire behaviour: Flame retardance: acc. to IEC 60-- Halogen acid gas emission: acc. to IEC 607- Smoke density: acc. to IEC 60 Calorific value (MJ/m): 0.7 (approx.) S IEC Security (Fire behaviour) IEC IEC EFP Grade EFP Grade Performance: Better than category 7 acc. EN 088 and IEC 66 excellent NEXT, low attenuation, excellent screening characteristics (individual and overall screen), low SKEW Bandwidth,00 MHz P > class E > 0 MHz > class E A > 00 MHz Performance (Cabling class, bandwidth) > class F > 600 MHz > class F A >,000 MHz > class G >,00 MHz Applications: Installation cable for generic cabling systems acc. ISO/IEC 80 and EN 07 (. edition). Ideal for all applications of classes D up to F A Multimedia (Video, Data, Voice) >0 GbE acc. IEEE 80. an (draft), Cable sharing, VoIP, PoE A > 00 MbE > GbE Application (Ethernet, TV) up to 0 GbE > 0 GbE > 0 GbE TV Mechanical characteristics: Bending radius: during installation: 8 x overall diameter (min.) after installation: x overall diameter (min.) Tensile strength: 0 (max.) Crush (N/00 mm):,000 Impact (number of shocks): 0 C AWG 7 AWG 6/ Construction (Conductor size, Tensile strength) AWG AWG AWG Electromagnetic behaviour: Transfer impedance at 0 MHz (mohm/m): (nominal value) Screening attenuation up to,000 MHz (db): 70 (nominal value) Coupling attenuation up to,000 MHz (db): 8 (nominal value) E > 0 db > 0 db EMC (Coupling attenuation) > 60 db > 70 db > 80 db 0

21 Electrical characteristics at 0 C: DC resistance (Ohm/km): 7. (max.) Insulation resistance (Gohm x km): (min.) Mutual capacitance (pf/m): 0 (approx.) Transfer capacitance (e) (pf/km):,00 (approx.) Signal velocity (c): 0.8 (approx.) Propagation delay (ns/00m): 0 (approx.) Skew at 00 MHz (ns/00m): (approx.) Characteristic impedance at 00 MHz (Ohm): 00 ± Test voltage Ueff (V):,000 Operating voltage Ueff (V): (max.) Frequency Attenuation NEXT PS-NEXT ACR PS-ACR EL-FEXT PS-ELFEXT RL MHz db/00m db db db@00m db@00m db@00m db@00m db typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 max.* min.* min.* min.* min.* min.* min.* min.* , , , * EN 088--/IEC 66- PS-A-NEXT/dB PS-A-NEXT@00m f/mhz P P P P Class E Class F MegaLine F0-0 S/F Chemical characteristics: Free of hazardous substances acc. to RoHS 00/9/EG Certificates and Approvals: Quality mark with production control: VDE Link performance: KERPEN ELine systems and further commercial cabling systems Inspection certificate: acc. to DIN respectively EN 00 In agreement to LVD (7//EEC): Thermal characteristics: Temperature range for fixed installation: -0 C up to + 60 C Temperature range for mobile operation: 0 C up to + 0 C Article number Size Overall diameter Weight Copper number Colour sheat mm kg/km kg/km 7KS7000 P 8.6 (approx.) 80 (approx.) 8 yellow, RAL 0 7KS7000 xp 8.6 x 7. (approx.) 6 (approx.) 96 yellow, RAL 0 Package: Drum,000 m

22 MegaLine MegaLine F0-0 S/F S P A C E Type: KS-0YSCH xxawg / PIMF Type: KS-0YSCH x(xxawg / PIMF) Construction: Conductor: bare copper wire, AWG / Insulation: cellular-pe, core-ø: max..0 mm Twisting element: Pair Twisting: pairs Overall screen: tinned copper wire braid Outer sheath: halogen-free, flame retardend compound Conductor Insulation Individual screen Overall screen Outer sheath Printing outer sheath: KERPEN MegaLine F0-0 S/F P H SPACE CODE VDE approval mark Production lot code Meter marking Colour code: wh/bu, wh/or, wh/gn, wh/bn Colour outer sheath: yellow, RAL 0 Fire behaviour: Flame retardance: acc. to IEC 60-- Halogen acid gas emission: acc. to IEC 607- Smoke density: acc. to IEC 60 Calorific value (MJ/m): 0.60/. (approx.) S IEC Security (Fire behaviour) IEC IEC EFP Grade EFP Grade Performance: Better than category 7 acc. EN 088 and IEC 66 excellent NEXT, excellent screening characteristics (individual and overall screen), low SKEW Bandwidth,00 MHz P > class E > 0 MHz > class E A > 00 MHz Performance (Cabling class, bandwidth) > class F > 600 MHz > class F A >,000 MHz > class G >,00 MHz Applications: Installation cable for generic cabling systems acc. ISO/IEC 80 and EN 07 (. edition). Ideal for all applications of classes D up to F A Multimedia (Video, Data, Voice) >0 GbE acc. IEEE 80. an (draft), Cable sharing, VoIP, PoE A > 00 MbE > GbE Application (Ethernet,TV) up to 0 GbE > 0 GbE > 0 GbE TV Mechanical characteristics: Bending radius: during installation: 8 x overall diameter (min.) after installation: x overall diameter (min.) Tensile strength: 0/0 (max.) Crush (N/00 mm):,000 Impact (number of shocks): 0 C AWG 7 AWG 6/ Construction (Conductor size, Tensile strength) AWG AWG AWG Electromagnetic behaviour: Transfer impedance at 0 MHz (mohm/m): (nominal value) Screening attenuation up to,000 MHz (db): 70 (nominal value) Coupling attenuation up to,000 MHz (db): 8 (nominal value) E > 0 db > 0 db EMC (Coupling attenuation) > 60 db > 70 db > 80 db

23 Electrical characteristics at 0 C: DC resistance (Ohm/km): 7 (max.) Insulation resistance (Gohm x km): (min.) Mutual capacitance (pf/m): (approx.) Transfer capacitance (e) (pf/km):,00 (approx.) Signal velocity (c): 0.8 (approx.) Propagation delay (ns/00m): 0 (approx.) Skew at 00 MHz (ns/00m): (approx.) Characteristic impedance at 00 MHz (Ohm): 00 ± Test voltage Ueff (V):,000 Operating voltage Ueff (V): (max.) Frequency Attenuation NEXT PS-NEXT ACR PS-ACR EL-FEXT PS-ELFEXT RL MHz db/00m db db db@00m db@00m db@00m db@00m db typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 max.* min.* min.* min.* min.* min.* min.* min.* , , * EN 088--/IEC 66- PS-A-NEXT@00m f/mhz PS-A-NEXT/dB P P P P Class E Class F MegaLine F0-0 S/F Chemical characteristics: Free of hazardous substances acc. to RoHS 00/9/EG Certificates and Approvals: Quality mark with production control: VDE Link performance: KERPEN ELine systems and further commercial cabling systems Inspection certificate: acc. to DIN respectively EN 00 In agreement to LVD (7//EEC): Thermal characteristics: Temperature range for fixed installation: -0 C up to + 60 C Temperature range for mobile operation: 0 C up to + 0 C Article number Size Overall diameter Weight Copper number Colour sheat mm kg/km kg/km 7KS70008 P 7. (approx.) 67 (approx.) 7 yellow, RAL 0 7KS70009 xp 7. x. (approx.) 6 (approx.) 7 yellow, RAL 0 Package: Drum,000 m

24 MegaLine MegaLine F6-90 S/F S P A C E Type: KS-0YSCH xxawg / PIMF Type: KS-0YSCH x(xxawg / PIMF) Construction: Conductor: bare copper wire, AWG / Insulation: cellular-pe, core-ø: max..0 mm Twisting element: Pair Individual screen: aluminium bonded polyester tape Twisting: pairs Overall screen: tinned copper wire braid Outer sheath: halogen-free, flame retardend compound Conductor Insulation Individual screen Overall screen Outer sheath Printing outer sheath: KERPEN MegaLine F6-90 S/F P H SPACE CODE VDE approval mark Production lot code Meter marking Colour code: wh/bu, wh/or, wh/gn, wh/bn Colour outer sheath: yellow, RAL 0 Fire behaviour: Flame retardance: acc. to IEC 60-- Halogen acid gas emission: acc. to IEC 607- Smoke density: acc. to IEC 60 Calorific value (MJ/m): 0.6/. (approx.) S IEC Security (Fire behaviour) IEC IEC EFP Grade EFP Grade Performance: Better than category 7 acc. EN 088 and IEC 66 excellent NEXT, excellent screening characteristics (individual and overall screen), low SKEW Bandwidth 900 MHz P > class E > 0 MHz > class E A > 00 MHz Performance (Cabling class, bandwidth) > class F > 600 MHz > class F A >,000 MHz > class G >,00 MHz Applications: Installation cable for generic cabling systems acc. ISO/IEC 80 and EN 07 (. edition). Ideal for all applications of classes D up to F Multimedia (Video, Data, Voice) >0 GbE acc. IEEE 80. an (draft), Cable sharing, VoIP, PoE A > 00 MbE > GbE Application (Ethernet, TV) up to 0 GbE > 0 GbE > 0 GbE TV Mechanical characteristics: Bending radius: during installation: 8 x overall diameter (min.) after installation: x overall diameter (min.) Tensile strength: 0/0 (max.) Crush (N/00mm):,000 Impact (number of shocks): 0 C AWG 7 AWG 6/ Construction (Conductor size, Tensile strength) AWG AWG AWG Electromagnetic behaviour: Transfer impedance at 0 MHz (mohm/m): (nominal value) Screening attenuation up to,000 MHz (db): 70 (nominal value) Coupling attenuation up to,000 MHz (db): 8 (nominal value) E > 0 db > 0 db EMC (Coupling attenuation) > 60 db > 70 db > 80 db

25 Electrical characteristics at 0 C: DC resistance (Ohm/km): 7 (max.) Insulation resistance (GOhm x km): (min.) Mutual capacitance (pf/m): (approx.) Transfer capacitance (e) (pf/km):,00 (approx.) Signal velocity (c): 0.8 (approx.) Propagation delay (ns/00m): 0 (approx.) Skew at 00 MHz (ns/00m): (approx.) Characteristic impedance at 00 MHz (Ohm): 00 ± Test voltage Ueff (V):,000 Operating voltage Ueff (V): (max.) Frequency Attenuation NEXT PS-NEXT ACR PS-ACR EL-FEXT PS-ELFEXT RL MHz db/00m db db db@00m db@00m db@00m db@00m db typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 max.* min.* min.* min.* min.* min.* min.* min.* * EN 088--/IEC 66- PS-A-NEXT/dB PS-A-NEXT@00m f/mhz P P P P Class E Class F MegaLine F6-90 S/F Chemical characteristics: Free of hazardous substances acc. to RoHS 00/9/EG Certificates and Approvals: Quality mark with production control: VDE Link performance: KERPEN ELine systems and further commercial cabling systems Inspection certificate: acc. to DIN respectively EN 00 In agreement to LVD (7//EEC): Thermal characteristics: Temperature range for fixed installation: -0 C up to + 60 C Temperature range for mobile operation: 0 C up to + 0 C Article number Size Overall diameter Weight Copper number Colour sheat mm kg/km kg/km 7KS7000 P 7. (approx.) 67 (approx.) 7 yellow, RAL 0 7KS700 xp 7. x. (approx.) 6 (approx.) 7 yellow, RAL 0 Package: Drum,000 m

26 MegaLine MegaLine F6-80 S/F S P A C E Type: KS-0YSCH xxawg / PIMF Type: KS-0YSCH x(xxawg / PIMF) Construction: Conductor: bare copper wire, AWG / Insulation: cellular-pe, core-ø: max..0 mm Twisting element: Pair Individual screen: aluminium bonded polyester tape Twisting: pairs Overall screen: tinned copper wire braid Outer sheath: halogen-free, flame retardend compound Conductor Insulation Individual screen Overall screen Outer sheath Printing outer sheath: KERPEN MegaLine F6-80 S/F P H SPACE CODE Number of registration Production lot code Meter marking Colour code: wh/bu, wh/or, wh/gn, wh/bn Colour outer sheath: yellow, RAL 0 Fire behaviour: Flame retardance: acc. to IEC 60-- Halogen acid gas emission: acc. to IEC 607- Smoke density: acc. to IEC 60 Calorific value (MJ/m): 0.6/. (approx.) S IEC Security (Fire behaviour) IEC IEC EFP Grade EFP Grade Performance: Better than category 7 acc. IEC 66 excellent NEXT, excellent screening characteristics (individual and overall screen), low SKEW Bandwidth 800 MHz P > class E > 0 MHz > class E A > 00 MHz Performance (Cabling class, bandwidth) > class F > 600 MHz > class F A >,000 MHz > class G >,00 MHz Applications: Installation cable for generic cabling systems acc. ISO/IEC 80 and EN 07 (. edition). Ideal for all applications of classes D up to F Multimedia (Video, Data, Voice) >0 GbE acc. IEEE 80. an (draft), Cable sharing, VoIP, PoE A > 00 MbE > GbE Application (Ethernet, TV) up to 0 GbE > 0 GbE > 0 GbE TV Mechanical characteristics: Bending radius: during installation: 8 x overall diameter (min.) after installation: x overall diameter (min.) Tensile strength: 0/0 (max.) Crush (N/00mm):,000 Impact (number of shocks): 0 C AWG 7 AWG 6/ Construction (Conductor size, Tensile strength) AWG AWG AWG Electromagnetic behaviour: Transfer impedance at 0 MHz (mohm/m): 0 (nominal value) Screening attenuation up to,000 MHz (db): (nominal value) Coupling attenuation up to,000 MHz (db): 80 (nominal value) E > 0 db > 0 db EMC (Coupling attenuation) > 60 db > 70 db > 80 db 6

27 Electrical characteristics at 0 C: DC resistance (Ohm/km): 7 (max.) Insulation resistance (Gohm x km): (min.) Mutual capacitance (pf/m): (approx.) Transfer capacitance (e) (pf/km):,00 (approx.) Signal velocity (c): 0.8 (approx.) Propagation delay (ns/00m): 0 (approx.) Skew at 00 MHz (ns/00m): (approx.) Characteristic impedance at 00 MHz (Ohm): 00 ± Test voltage Ueff (V):,000 Operating voltage Ueff (V): (max.) Frequency Attenuation NEXT PS-NEXT ACR PS-ACR EL-FEXT PS-ELFEXT RL MHz db/00m db db db@00m db@00m db@00m db@00m db typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 max.* min.* min.* min.* min.* min.* min.* min.* * EN (draft)/en 088--/IEC 66- PS-A-NEXT/dB PS-A-NEXT@00m f/mhz P P P P Class E Class F MegaLine F6-80 S/F Chemical characteristics: Free of hazardous substances acc. to RoHS 00/9/EG Certificates and Approvals: Quality mark with production control: VDE Number of registration VDE Link performance: KERPEN ELine systems and further commercial cabling systems Inspection certificate: acc. to DIN respectively EN 00 In agreement to LVD (7//EEC): Thermal characteristics: Temperature range for fixed installation: -0 C up to + 60 C Temperature range for mobile operation: 0 C up to + 0 C Article number Size Overall diameter Weight Copper number Colour sheat mm kg/km kg/km 7KS700 P 7. (approx.) 8 (approx.) yellow, RAL 0 7KS700 xp 7. x.0 (approx.) 0 (approx.) 68 yellow, RAL 0 Package: Drum,000 m 7

28 MegaLine MegaLine E-70 S/F S P A C E Type: KS-0YSCH xxawg / PIMF Type: KS-0YSCH x(xxawg / PIMF) Construction: Conductor: bare copper wire, AWG / Insulation: cellular-pe, core-ø: max..0 mm Twisting element: Pair Individual screen: aluminium bonded polyester tape Twisting: pairs Overall screen: tinned copper wire braid Outer sheath: halogen-free, flame retardend compound Conductor Insulation Individual screen Overall screen Outer sheath Printing outer sheath: KERPEN MegaLine E-70 S/F P H SPACE CODE VDE approval mark Production lot code Meter marking Farbcode: wh/bu, wh/or, wh/gn, wh/bn Colour outer sheath: yellow, RAL 0 Fire behaviour: Flame retardance: acc. to IEC 60-- Halogen acid gas emission: acc. to IEC 607- Smoke density: acc. to IEC 60 Calorific value (MJ/m): 0.6/. (approx.) S IEC Security (Fire behaviour) IEC IEC EFP Grade EFP Grade Performance: Better than category 6 acc. EN 088 and IEC 66 very good NEXT, very good screening characteristics (individual and overall screen), low SKEW Bandwidth 700 MHz P > class E > 0 MHz > class E A > 00 MHz Performance (Cabling class, bandwidth) > class F > 600 MHz > class F A >,000 MHz > class G >,00 MHz Applications: Installation cable for generic cabling systems acc. ISO/IEC 80 and EN 07 (. edition). Ideal for all applications of classes D up to E A up to 0 GbE acc. IEEE 80. an (draft), Cable sharing, VoIP, PoE A > 00 MbE > GbE Application (Ethernet, TV) up to 0 GbE > 0 GbE > 0 GbE TV Mechanical characteristics: Bending radius: during installation: 8 x overall diameter (min.) after installation: x overall diameter (min.) Tensile strength: 0/0 (max.) Crush (N/00mm):,000 Impact (number of shocks): 0 C AWG 7 AWG 6/ Construction (Conductor size, Tensile strength) AWG AWG AWG Electromagnetic behaviour: Transfer impedance at 0 MHz (mohm/m): (nominal value) Screening attenuation up to,000 MHz (db): 60 (nominal value) Coupling attenuation up to,000 MHz (db): 80 (nominal value) E > 0 db > 0 db EMC (Coupling attenuation) > 60 db > 70 db > 80 db 8

29 Electrical characteristics at 0 C: DC resistance (Ohm/km): 7 (max.) Insulation resistance (Gohm x km): (min.) Mutual capacitance (pf/m): (approx.) Transfer capacitance (e) (pf/km):,00 (approx.) Signal velocity (c): 0.8 (approx.) Propagation delay (ns/00m): 0 (approx.) Skew at 00 MHz (ns/00m): 7 (approx.) Characteristic impedance at 00 MHz (Ohm): 00 ± Test voltage Ueff (V):,000 Operating voltage Ueff (V): (max.) Frequency Attenuation NEXT PS-NEXT ACR PS-ACR EL-FEXT PS-ELFEXT RL MHz db/00m db db db@00m db@00m db@00m db@00m db typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 max.* min.* min.* min.* min.* min.* min.* min.* * EN (draft)/en 088--/IEC 66- PS-A-NEXT/dB PS-A-NEXT@00m f/mhz P P P P Class E Class F MegaLine E-70 S/F Chemical characteristics: Free of hazardous substances acc. to RoHS 00/9/EG Certificates and Approvals: Quality mark with production control: VDE Link performance: KERPEN ELine systems and further commercial cabling systems Inspection certificate: acc. to DIN respectively EN 00 In agreement to LVD (7//EEC): Thermal characteristics: Temperature range for fixed installation: -0 C up to + 60 C Temperature range for mobile operation: 0 C up to + 0 C Article number Size Overall diameter Weight Copper number Colour sheat mm kg/km kg/km 7KS600 P 7.6 (approx.) 67 (approx.) yellow, RAL 0 7KS600 xp 7. x. (approx.) 6 (approx.) 68 yellow, RAL 0 Package: Drum,000 m 9

30 MegaLine MegaLine E-70 F/F S P A C E Type: KS-0YS(ST)H xxawg / PIMF Type: KS-0YS(ST)H x(xxawg / PIMF) Construction: Conductor: bare copper wire, AWG / Insulation: cellular-pe, core-ø: max..0 mm Twisting element: Pair Individual screen: aluminium bonded polyester tape Twisting: pairs Overall screen: aluminium bonded polyester tape, metal side inside, with underlayed tinned copper drain wire AWG / Outer sheath: halogen-free, flame retardend compound Conductor Insulation Individual screen Overall screen Outer sheath Copper drain wire Printing outer sheath: KERPEN MegaLine E-70 F/F P H SPACE CODE VDE approval mark Production lot code Meter marking Colour code: wh/bu, wh/or, wh/gn, wh/bn Colour outer sheath: yellow, RAL 0 Fire behaviour: Flame retardance: acc. to IEC 60-- Halogen acid gas emission: acc. to IEC 607- Smoke density: acc. to IEC 60 Calorific value (MJ/m): 0.6/. (approx.) S IEC Security (Fire behaviour) IEC IEC EFP Grade EFP Grade Performance: Better than category 6 acc. EN 088 and IEC 66 very good NEXT, good screening characteristics (individual and overall screen), low SKEW Bandwidth 700 MHz P > class E > 0 MHz > class E A > 00 MHz Performance (Cabling class, bandwidth) > class F > 600 MHz > class F A >,000 MHz > class G >,00 MHz Applications: Installation cable for generic cabling systems acc. ISO/IEC 80 and EN 07 (. edition). Ideal for all applications of classes D up to E A up to 0 GbE acc. IEEE 80. an (draft), Cable sharing, VoIP, PoE A > 00 MbE > GbE Application (Ethernet, TV) up to 0 GbE > 0 GbE > 0 GbE TV Mechanical characteristics: Bending radius: during installation: 8 x overall diameter (min.) after installation: x overall diameter (min.) Tensile strength: 0/0 (max.) Crush (N/00mm):,000 Impact (number of shocks): 0 C AWG 7 AWG 6/ Construction (Conductor size, Tensile strength) AWG AWG AWG Electromagnetic behaviour: Transfer impedance at 0 MHz (mohm/m): 0 (nominal value) Screening attenuation up to,000 MHz (db): 60 (nominal value) Coupling attenuation up to,000 MHz (db): 70 (nominal value) E > 0 db > 0 db EMC (Coupling attenuation) > 60 db > 70 db > 80 db 0

31 Electrical characteristics at 0 C: DC resistance (Ohm/km): 8 (max.) Insulation resistance (Gohm x km): (min.) Mutual capacitance (pf/m): (approx.) Transfer capacitance (e) (pf/km):,00 (approx.) Signal velocity (c): 0.8 (approx.) Propagation delay (ns/00m): 7 (approx.) Skew at 00 MHz (ns/00m): 7 (approx.) Characteristic impedance at 00 MHz (Ohm): 00 ± Test voltage Ueff (V):,000 Operating voltage Ueff (V): (max.) Frequency Attenuation NEXT PS-NEXT ACR PS-ACR EL-FEXT PS-ELFEXT RL MHz db/00m db db db@00m db@00m db@00m db@00m db typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 max.* min.* min.* min.* min.* min.* min.* min.* * EN (draft)/en 088--/IEC 66- PS-A-NEXT@00m f/mhz PS-A-NEXT/dB P P P P Class E Class F MegaLine E-70 F/F Chemical characteristics: Free of hazardous substances acc. to RoHS 00/9/EG Certificates and Approvals: Quality mark with production control: VDE Link performance: KERPEN ELine systems and further commercial cabling systems Inspection certificate: acc. to DIN respectively EN 00 In agreement to LVD (7//EEC): Thermal characteristics: Temperature range for fixed installation: -0 C up to + 60 C Temperature range for mobile operation: 0 C up to + 0 C Article number Size Overall diameter Weight Copper number Colour sheat mm kg/km kg/km 7KS600 P 7. (approx.) 8 (approx.). yellow, RAL 0 7KS600 xp 7. x. (approx.) 0 (approx.) 7 yellow, RAL 0 Package: Drum,000 m

32 MegaLine MegaLine E- U/F S P A C E Type: KS-0YSH xxawg / PIMF Type: KS-0YSH x(xxawg / PIMF) Construction: Conductor: bare copper wire, AWG / Insulation: cellular-pe, core-ø: max..0 mm Twisting element: Pair Individual screen: aluminium bonded polyester tape Twisting: pairs Tape: plastic foil (optional) with underlayed tinned copper drain wire AWG / Outer sheath: halogen-free, flame retardend compound Conductor Insulation Individual screen Outer sheath Copper drain wire Printing outer sheath: KERPEN MegaLine E- U/F P H SPACE CODE VDE approval mark Production lot code Meter marking Colour code: wh/bu, wh/or, wh/gn, wh/bn Colour outer sheath: yellow, RAL 0 Fire behaviour: Flame retardance: acc. to IEC 60-- Halogen acid gas emission: acc. to IEC 607- Smoke density: acc. to IEC 60 Calorific value (MJ/m): 0.6/. (approx.) S IEC Security (Fire behaviour) IEC IEC EFP Grade EFP Grade Performance: Better than category 6 acc. EN 088 and IEC 66 very good NEXT, low SKEW Bandwidth 0 MHz P > class E > 0 MHz > class E A > 00 MHz Performance (Cabling class, bandwidth) > class F > 600 MHz > class F A >,000 MHz > class G >,00 MHz Applications: Installation cable for generic cabling systems acc. ISO/IEC 80 and EN 07 (. edition). Ideal for all applications of classes D up to E up to GbE acc. IEEE 80. an (draft), Cable sharing, VoIP, PoE A > 00 MbE > GbE Application (Ethernet, TV) up to 0 GbE > 0 GbE > 0 GbE TV Mechanical characteristics: Bending radius: during installation: 8 x overall diameter (min.) after installation: x overall diameter (min.) Tensile strength: 0/0 (max.) Crush (N/00mm):,000 Impact (number of shocks): 0 C AWG 7 AWG 6/ Construction (Conductor size, Tensile strength) AWG AWG AWG Electromagnetic behaviour: Transfer impedance at 0 MHz (mohm/m): 80 (nominal value) Screening attenuation up to,000 MHz (db): 0 (nominal value) Coupling attenuation up to,000 MHz (db): 60 (nominal value) E > 0 db > 0 db EMC (Coupling attenuation) > 60 db > 70 db > 80 db

33 Electrical characteristics at 0 C: DC resistance (Ohm/km): 8 (max.) Insulation resistance (Gohm x km): (min.) Mutual capacitance (pf/m): (approx.) Transfer capacitance (e) (pf/km):,00 (approx.) Signal velocity (c): 0.8 (approx.) Propagation delay (ns/00m): 0 (approx.) Skew at 00 MHz (ns/00m): 7 (approx.) Characteristic impedance at 00 MHz (Ohm): 00 ± Test voltage Ueff (V):,000 Operating voltage Ueff (V): (max.) Frequency Attenuation NEXT PS-NEXT ACR PS-ACR EL-FEXT PS-ELFEXT RL MHz db/00m db db db@00m db@00m db@00m db@00m db typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 max.* min.* min.* min.* min.* min.* min.* min.* * EN 088--/IEC 66- PS-A-NEXT@00m f/mhz PS-A-NEXT/dB P P P P Class E Class F MegaLine E- U/F Chemical characteristics: Free of hazardous substances acc. to RoHS 00/9/EG Certificates and Approvals: Quality mark with production control: VDE Number of registration VDE Link performance: KERPEN ELine systems and further commercial cabling systems Inspection certificate: acc. to DIN respectively EN 00 In agreement to LVD (7//EEC): Thermal characteristics: Temperature range for fixed installation: -0 C up to + 60 C Temperature range for mobile operation: 0 C up to + 0 C Article number Size Overall diameter Weight Copper number Colour sheat mm kg/km kg/km 7KS6000 P 7. (approx.) (approx.). yellow, RAL 0 7KS60006 xp 7. x. (approx.) (approx.) 7 yellow, RAL 0 Package: Drum,000 m

34 MegaLine MegaLine E-0 F/U S P A C E Type: KS-Y(ST)H xxawg / Construction: Conductor: bare copper wire, AWG / Insulation: PE Twisting element: Pair Twisting: pairs Overall screen: aluminium bonded polyester tape, metal side inside, with underlayed tinned copper drain wire AWG / Outer sheath: halogen-free, flame retardend compound Conductor Insulation Central cross element Overall screen Outer sheath Copper drain wire Printing outer sheath: KERPEN MegaLine E-0 F/U P H SPACE CODE Production lot code Meter marking Colour code: whbu/bu, whor/or, whgn/gn, whbn/bn Colour outer sheath: yellow, RAL 0 Fire behaviour: Flame retardance: acc. to IEC 60-- Halogen acid gas emission: acc. to IEC 607- Smoke density: acc. to IEC 60 Calorific value (MJ/m): 0.7 (approx.) S IEC Security (Fire behaviour) IEC IEC EFP Grade EFP Grade Performance: Better than category 6 acc. EN 088 and IEC 66 Bandwidth 00 MHz P > class E > 0 MHz > class E A > 00 MHz > class F > 600 MHz > class F A >,000 MHz > class G >,00 MHz Performance (Cabling class, bandwidth) Applications: Installation cable for generic cabling systems acc. ISO/IEC 80 and EN 07 (. edition). Ideal for all applications of classes D up to E up to GbE acc. IEEE 80. ab, VoIP, PoE A > 00 MbE > GbE Application (Ethernet, TV) up to 0 GbE > 0 GbE > 0 GbE TV Mechanical characteristics: Bending radius: during installation: 8 x overall diameter (min.) after installation: x overall diameter (min.) Tensile strength: 0 (max.) Crush (N/00mm):,000 Impact (number of shocks): 0 C AWG 7 AWG 6/ Construction (Conductor size, Tensile strength) AWG AWG AWG Electromagnetic behaviour: Transfer impedance at 0 MHz (mohm/m): 0 (nominal value) Screening attenuation up to,000 MHz (db): 0 (nominal value) Coupling attenuation up to,000 MHz (db): 70 (nominal value) E > 0 db > 0 db EMC (Coupling attenuation) > 60 db > 70 db > 80 db

35 Electrical characteristics at 0 C: DC resistance (Ohm/km): 7 (max.) Insulation resistance (Gohm x km): (min.) Mutual capacitance (pf/m): 6 (approx.) Transfer capacitance (e) (pf/km):,00 (approx.) Signal velocity (c): 0.7 (approx.) Propagation delay (ns/00m): 80 (approx.) Skew at 00 MHz (ns/00m): (approx.) Characteristic impedance at 00 MHz (Ohm): 00 ± Test voltage Ueff (V):,000 Operating voltage Ueff (V): (max.) Frequency Attenuation NEXT PS-NEXT ACR PS-ACR EL-FEXT PS-ELFEXT RL MHz db/00m db db db@00m db@00m db@00m db@00m db typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 max.* min.* min.* min.* min.* min.* min.* min.* * EN 088--/IEC 66- A-EL-FEXT/dB PS-A-NEXT@00m f/mhz P P P P Class E Class F MegaLine E-0 F/U Certificates and Approvals: Link performance: KERPEN ELine systems and further commercial cabling systems Inspection certificate: acc. to DIN respectively EN 00 In agreement to LVD (7//EEC): Thermal characteristics: Temperature range for fixed installation: -0 C up to + 60 C Temperature range for mobile operation: 0 C up to + 0 C Article number Size Overall diameter Weight Copper number Colour sheat mm kg/km kg/km 7KS6000 P 7. (approx.) (approx.) yellow, RAL 0 Package: Drum,000 m

36 MegaLine MegaLine E-0 U/U S P A C E Type: KS-YH xxawg / Construction: Conductor: bare copper wire, AWG / Insulation: PE Twisting element: Pair Twisting: pairs Tape: plastic foil (optional) Outer sheath: halogen-free, flame retardend compound Conductor Insulation Central cross element Outer sheath Printing outer sheath: KERPEN MegaLine E-0 U/U P H SPACE CODE Production lot code Meter marking Colour code: whbu/bu, whor/or, whgn/gn, whbn/bn Colour outer sheath: yellow, RAL 0 Fire behaviour: Flame retardance: acc. to IEC 60-- Halogen acid gas emission: acc. to IEC 607- Smoke density: acc. to IEC 60 Calorific value (MJ/m): 0.6 (approx.) S IEC Security (Fire behaviour) IEC IEC EFP Grade EFP Grade Performance: Better than category 6 acc. EN 088 and IEC 66 Bandwidth 00 MHz P > class E > 0 MHz > class E A > 00 MHz > class F > 600 MHz > class F A >,000 MHz > class G >,00 MHz Performance (Cabling class, bandwidth) Applications: Installation cable for generic cabling systems acc. ISO/IEC 80 and EN 07 (. edition). Suitable for all applications of classes D up to E up to GbE acc. IEEE 80. ab, VoIP, PoE A > 00 MbE > GbE Application (Ethernet, TV) up to 0 GbE > 0 GbE > 0 GbE TV Mechanical characteristics: Bending radius: during installation: 8 x overall diameter (min.) after installation: x overall diameter (min.) Tensile strength(n): 0 (max.) Crush (N/00mm):,000 Impact (number of shocks): 0 C AWG 7 AWG 6/ Construction (Conductor size, Tensile strength) AWG AWG AWG Electromagnetic behaviour: Coupling attenuation up to,000 MHz (db): (nominal value) E > 0 db > 0 db > 60 db > 70 db > 80 db EMC (Coupling attenuation) 6

37 Electrical characteristics at 0 C: DC resistance (Ohm/km): 78 (max.) Insulation resistance (Gohm x km): (min.) Mutual capacitance (pf/m): 0 (approx.) Transfer capacitance (e) (pf/km):,00 (approx.) Signal velocity (c): 0.67 (approx.) Propagation delay (ns/00m): 8 (approx.) Skew at 00 MHz (ns/00m): 0 (approx.) Characteristic impedance at 00 MHz (Ohm): 00 ± Test voltage Ueff (V):,000 Operating voltage Ueff (V): (max.) Frequency Attenuation NEXT PS-NEXT ACR PS-ACR EL-FEXT PS-ELFEXT RL MHz db/00m db db db@00m db@00m db@00m db@00m db typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 max.* min.* min.* min.* min.* min.* min.* min.* * EN /IEC 66- MegaLine E-0 U/U Certificates and Approvals: Link performance: KERPEN ELine systems and further commercial cabling systems Inspection certificate: acc. to DIN respectively EN 00 In agreement to LVD (7//EEC): Thermal characteristics: Temperature range for fixed installation: -0 C up to + 60 C Temperature range for mobile operation: 0 C up to + 0 C Article number Size Overall diameter Weight Copper number Colour sheat mm kg/km kg/km 7KS6000 P 6. (approx.) (approx.) yellow, RAL 0 Package: Drum,000 m, 00 m, box 00 m 7

38 MegaLine MegaLine D-0 SF/U S P 0 A C E Type: KS-0YS(ST+C)H xxawg / Type: KS-0YS(ST+C)H x(xxawg /) Construction: Conductor: bare copper wire, AWG / Insulation: cellular-pe, core-ø: nominal value. mm Twisting element: Pair Twisting: pairs Overall screen: aluminum-bonded polyester tape and tinned copper wire braid Outer sheath: halogen-free, flame retardend compound Conductor Insulation Overall screen Outer sheath Printing outer sheath: KERPEN MegaLine D-0 SF/U P H SPACE CODE 0 Production lot code Meter marking Colour code: whbu/bu, whor/or, whgn/gn, whbn/bn Colour outer sheath: yellow, RAL 0 Fire behaviour: Flame retardance: acc. to IEC 60-- Halogen acid gas emission: acc. to IEC 607- Smoke density: acc. to IEC 60 Calorific value (MJ/m): 0./0.7 (approx.) S IEC Security (Fire behaviour) IEC IEC EFP Grade EFP Grade Performance: Better than category acc. EN 088 and IEC 66 very good screening characteristics Bandwidth 00 MHz P > class E > 0 MHz > class E A > 00 MHz Performance (Cabling class, bandwidth) > class F > 600 MHz > class F A >,000 MHz > class G >,00 MHz Applications: Installation cable for generic cabling systems acc. ISO/IEC 80 and EN 07 (. edition). Ideal for all applications of class D up to GbE acc. IEEE 80. ab, VoIP, PoE A > 00 MbE > GbE Application (Ethernet, TV) up to 0 GbE > 0 GbE > 0 GbE TV Mechanical characteristics: Bending radius: during installation: 8 x overall diameter (min.) after installation: x overall diameter (min.) Tensile strength: 8/70 (max.) Crush (N/00mm):,000 Impact (number of shocks): 0 C AWG 7 AWG 6/ Construction (Conductor size, Tensile strength) AWG AWG AWG Electromagnetic behaviour: Transfer impedance at 0 MHz (mohm/m): 0 (nominal value) Screening attenuation up to,000 MHz (db): (nominal value) Coupling attenuation up to,000 MHz (db): 70 (nominal value) E > 0 db > 0 db EMC (Coupling attenuation) > 60 db > 70 db > 80 db 8

39 Electrical characteristics at 0 C: DC resistance (Ohm/km): 9 (max.) Insulation resistance (Gohm x km): 00 (min.) Mutual capacitance (pf/m): (approx.) Transfer capacitance (e) (pf/km):,00 (approx.) Signal velocity (c): 0.7 (approx.) Propagation delay (ns/00m): 0 (approx.) Skew at 00 MHz (ns/00m): (approx.) Characteristic impedance at 00 MHz (Ohm): 00 ± Test voltage Ueff (V):,000 Operating voltage Ueff (V): (max.) Frequency Attenuation NEXT PS-NEXT ACR PS-ACR EL-FEXT PS-ELFEXT RL MHz db/00m db db db@00m db@00m db@00m db@00m db typ. Cat. typ. Cat. typ. Cat. typ. Cat. typ. Cat. typ. Cat. typ. Cat. typ. Cat. max.* min.* min.* min.* min.* min.* min.* min.* , , * EN 088--/IEC 66- MegaLine D-0 SF/U Chemical characteristics: Free of hazardous substances acc. to RoHS 00/9/EG Certificates and Approvals: Link performance: KERPEN ELine systems and further commercial cabling systems Inspection certificate: acc. to DIN respectively EN 00 In agreement to LVD (7//EEC): Thermal characteristics: Temperature range for fixed installation: -0 C up to + 60 C Temperature range for mobile operation: 0 C up to + 0 C Article number Size Overall diameter Weight Copper number Colour sheat mm kg/km kg/km 7KS000 P 6.0 (approx.) (approx.) 6 yellow, RAL 0 7KS0006 xp 6.0 x. (approx.) 86 (approx.) yellow, RAL 0 Package: Drum,000 m 9

40 MegaLine MegaLine D-0 F/U S P 0 A C E Type: KS-Y(ST)H xxawg / Construction: Conductor: bare copper wire, AWG / Insulation: PE Twisting element: Pair Twisting: pairs Overall screen: aluminium bonded polyester tape, metal side inside, with underlayed tinned copper drain wire AWG / Outer sheath: halogen-free, flame retardend compound Conductor Insulation Overall screen Outer sheath Copper drain wire Printing outer sheath: KERPEN MegaLine D-0 F/U P H SPACE CODE 0 Production lot code Meter marking" Colour code: whbu/bu, whor/or, whgn/gn, whbn/bn Colour outer sheath: yellow, RAL 0 Fire behaviour: Flame retardance: acc. to IEC 60-- Halogen acid gas emission: acc. to IEC 607- Smoke density: acc. to IEC 60 Calorific value (MJ/m): 0. (approx.) S IEC Security (Fire behaviour) IEC IEC EFP Grade EFP Grade Performance: Better than category acc. EN 088 and IEC 66 Bandwidth 00 MHz P > class E > 0 MHz > class E A > 00 MHz > class F > 600 MHz > class F A >,000 MHz > class G >,00 MHz Performance (Cabling class, bandwidth) Applications: Installation cable for generic cabling systems acc. ISO/IEC 80 and EN 07 (. edition). Ideal for all applications of class D up to GbE acc. IEEE 80. ab, VoIP, PoE A > 00 MbE > GbE Application (Ethernet, TV) up to 0 GbE > 0 GbE > 0 GbE TV Mechanical characteristics: Bending radius: during installation: 8 x overall diameter (min.) after installation: x overall diameter (min.) Tensile strength: 8 (max.) Crush (N/00mm):,000 Impact (number of shocks): 0 C AWG 7 AWG 6/ Construction (Conductor size, Tensile strength) AWG AWG AWG Electromagnetic behaviour: Transfer impedance at 0 MHz (mohm/m): 80 (nominal value) Screening attenuation up to,000 MHz (db): 0 (nominal value) Coupling attenuation up to,000 MHz (db): 60 (nominal value) E > 0 db > 0 db EMC (Coupling attenuation) > 60 db > 70 db > 80 db 0

41 Electrical characteristics at 0 C: DC resistance (Ohm/km): 9. (max.) Insulation resistance (Gohm x km): 00 (min.) Mutual capacitance (pf/m): 0 (approx.) Transfer capacitance (e) (pf/km):,00 (approx.) Signal velocity (c): 0.66 (approx.) Propagation delay (ns/00m): 7 (approx.) Skew at 00 MHz (ns/00m): (approx.) Characteristic impedance at 00 MHz (Ohm): 00 ± Test voltage Ueff (V):,000 Operating voltage Ueff (V): (max.) Frequency Attenuation NEXT PS-NEXT ACR PS-ACR EL-FEXT PS-ELFEXT RL MHz db/00m db db db@00m db@00m db@00m db@00m db typ. Cat. typ. Cat. typ. Cat. typ. Cat. typ. Cat. typ. Cat. typ. Cat. typ. Cat. max.* min.* min.* min.* min.* min.* min.* min.* * EN 088--/IEC 66- MegaLine D-0 F/U Certificates and Approvals: Link performance: KERPEN ELine systems and further commercial cabling systems Inspection certificate: acc. to DIN respectively EN 00 In agreement to LVD (7//EEC): Thermal characteristics: Temperature range for fixed installation: -0 C up to + 60 C Temperature range for mobile operation: 0 C up to + 0 C Article number Size Overall diameter Weight Copper number Colour sheat mm kg/km kg/km 7KS000 P 6. (approx.) 7 (approx.) 8 yellow, RAL 0 Package: Drum,000 m

42 MegaLine MegaLine D-0 U/U S P 0 A C E Type: KS-YH xxawg / Construction: Conductor: bare copper wire, AWG / Insulation: PE Twisting element: Pair Twisting: pairs Outer sheath: halogen-free, flame retardend compound Conductor Insulation Outer sheath Printing outer sheath: KERPEN MegaLine D-0 U/U P H SPACE CODE 0 Production lot code Meter marking Colour code: whbu/bu, whor/or, whgn/gn, whbn/bn Colour outer sheath: yellow, RAL 0 Fire behaviour: Flame retardance: acc. to IEC 60-- Halogen acid gas emission: acc. to IEC 607- Smoke density: acc. to IEC 60 Calorific value (MJ/m): 0.0 (approx.) S IEC Security (Fire behaviour) IEC IEC EFP Grade EFP Grade Performance: Better than category acc. EN 088 and IEC 66 Bandwidth 00 MHz P > class E > 0 MHz > class E A > 00 MHz > class F > 600 MHz > class F A >,000 MHz > class G >,00 MHz Performance (Cabling class, bandwidth) Applications: Installation cable for generic cabling systems acc. ISO/IEC 80 and EN 07 (. edition). Suitable for all applications of class D up to GbE acc. IEEE 80. ab, VoIP, PoE A > 00 MbE > GbE Application (Ethernet, TV) up to 0 GbE > 0 GbE > 0 GbE TV Mechanical characteristics: Bending radius: during installation: 8 x overall diameter (min.) after installation: x overall diameter (min.) Tensile strength: 8 (max.) Crush (N/00mm):,000 Impact (number of shocks): 0 C AWG 7 AWG 6/ Construction (Conductor size, Tensile strength) AWG AWG AWG Electromagnetic behaviour: Coupling attenuation up to,000 MHz (db): (nominal value) E > 0 db > 0 db EMC (Coupling attenuation) > 60 db > 70 db > 80 db

43 Electrical characteristics at 0 C: DC resistance (Ohm/km): 9. (max.) Insulation resistance (Gohm x km): (min.) Mutual capacitance (pf/m): 6 (approx.) Transfer capacitance (e) (pf/km):,00 (approx.) Signal velocity (c): 0.68 (approx.) Propagation delay (ns/00m): 7 (approx.) Skew at 00 MHz (ns/00m): (approx.) Characteristic impedance at 00 MHz (Ohm): 00 ± Test voltage Ueff (V):,000 Operating voltage Ueff (V): (max.) Frequency Attenuation NEXT PS-NEXT ACR PS-ACR EL-FEXT PS-ELFEXT RL MHz db/00m db db db@00m db@00m db@00m db@00m db typ. Cat. typ. Cat. typ. Cat. typ. Cat. typ. Cat. typ. Cat. typ. Cat. typ. Cat. max.* min.* min.* min.* min.* min.* min.* min.* * EN 088--/IEC 66- MegaLine D-0 U/U Certificates and Approvals: Link performance: KERPEN ELine systems and further commercial cabling systems Inspection certificate: nach acc. to DIN respectively EN 00 In agreement to LVD (7//EEC): Thermal characteristics: Temperature range for fixed installation: -0 C up to + 60 C Temperature range for mobile operation: 0 C up to + 0 C Article number Size Overall diameter Weight Copper number Colour sheat mm kg/km kg/km 7KS000 P. (approx.) 0 (approx.) 7. yellow, RAL 0 Package: Drum,000 m/00 m, box 00 m

44 MegaLine MegaLine F0-0 S/F flex S P A C E Type: KS-0YSCH xxawg 6/7 PIMF Type: KS-0YSCH xxawg 6/7 PIMF Construction: Conductor: bare stranded copper wire, AWG 6/7 Insulation: cellular-pe, core-ø: max..0 mm Twisting element: Pair Individual screen: aluminium bonded polyester tape Twisting: pairs Overall screen: tinned copper wire braid Outer sheath: halogen-free, flame retardend compound Conductor Insulation Individual screen Overall screen Outer sheath Printing outer sheath: KERPEN MegaLine F0-0 S/F flex P H SPACE CODE VDE approval mark Production lot code Meter marking Colour code: wh/bu, wh/or, wh/gn, wh/bn Colour outer sheath: grey, RAL 70; yellow, RAL 0; green, RAL 608; blue, RAL 0; red, RAL 000 Fire behaviour: Flame retardance: acc. to IEC 60-- Halogen acid gas emission: acc. to IEC 607- Smoke density: acc. to IEC 60 Calorific value (MJ/m): 0.8 (approx.) S IEC Security (Fire behaviour) IEC IEC EFP Grade EFP Grade Performance: Better than category 7 acc. EN 088 and IEC 66 excellent NEXT, low attenuation, excellent screening characteristics (individual and overall screen), low SKEW, Bandwidth,00 MHz P > class E > 0 MHz > class E A > 00 MHz Performance (Cabling class, bandwidth) > class F > 600 MHz > class F A >,000 MHz > class G >,00 MHz Applications: Connecting cable and patch cord for generic cabling systems acc. ISO/IEC 80 and EN 07 (. edition) and for residential cabling and SOHO acc. ISO/IEC 08 and EN 07- (draft). Ideal for all applications of classes D up to F A Multimedia (TV, Video, Data, Voice) >0 GbE acc. IEEE 80. an (draft), Cable sharing, VoIP, PoE A > 00 MbE > GbE Application (Ethernet, TV) up to 0 GbE > 0 GbE > 0 GbE TV Mechanical characteristics: Bending radius: during operation: min. x overall diameter Tensile strength: 60 (max.) C AWG 7 AWG 6/ Construction (Conductor size, Tensile strength) AWG AWG AWG Electromagnetic behaviour: Transfer impedance at 0 MHz (mohm/m): (nominal value) Screening attenuation up to,000 MHz (db): 60 (nominal value) Coupling attenuation up to,000 MHz (db): 8 (nominal value) E > 0 db > 0 db EMC (Coupling attenuation) > 60 db > 70 db > 80 db

45 Electrical characteristics at 0 C: DC resistance (Ohm/km): 0 (max.) Insulation resistance (Gohm x km): (min.) Mutual capacitance (pf/m): (approx.) Signal velocity (c): 0.7 (approx.) Propagation delay (ns/00m): 60 (approx.) Skew at 00 MHz (ns/00m):. (approx.) Characteristic impedance at 00 MHz (Ohm): 00 ± Test voltage Ueff (V):,000 Operating voltage Ueff (V): (max.) Frequency Attenuation NEXT PS-NEXT ACR PS-ACR EL-FEXT PS-ELFEXT RL MHz db/0m db db db@0m db@0m db@0m db@0m db typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 max.* min.* min.* min.* min.* min.* min.* min.* , , , * EN /IEC 66-6 MegaLine F0-0 S/F flex Chemical characteristics: Free of hazardous substances acc. to RoHS 00/9/EG Certificates and Approvals: Quality mark with production control: VDE Link performance: KERPEN ELine systems and further commercial cabling systems Inspection certificate: acc. to DIN respectively EN 00 In agreement to LVD (7//EEC): Thermal characteristics: Temperature range for fixed installation: -0 C up to + 60 C Temperature range for mobile operation: 0 C up to + 0 C Article number Size Overall diameter Weight Copper number Colour sheat mm kg/km kg/km 7KS7000 P 6.0 (approx.) (approx.). grey, RAL 70 7KS7000 P 6.0 (approx.) (approx.). yellow, RAL 0 7KS7000 P 6.0 (approx.) (approx.). green, RAL 608 7KS70006 P 6.0 (approx.) (approx.). blue, RAL 0 7KS70007 P 6.0 (approx.) (approx.). red, RAL 000 Package: Drum,000 m

46 MegaLine MegaLine F6-90 S/F flex S P A C E Type: KS-0YSCH xxawg 7/7 PIMF Construction: Conductor: bare stranded copper wire, AWG 7/7 Insulation: cellular-pe, core-ø: max..0 mm Twisting element: Pair Individual screen: aluminium bonded polyester tape Twisting: pairs Overall screen: tinned copper wire braid Outer sheath: halogen-free, flame retardend compound Conductor Insulation Individual screen Overall screen Outer sheath Printing outer sheath: KERPEN MegaLine F6-90 S/F flex P H SPACE CODE Number of registration VDE 8080 Production lot code Meter marking Colour code: wh/bu, wh/or, wh/gn, wh/bn Colour outer sheath: grey, RAL 70; yellow, RAL 0; green, RAL 608; blue, RAL 0; red, RAL 000 Fire behaviour: Flame retardance: acc. to IEC 60-- Halogen acid gas emission: acc. to IEC 607- Smoke density: acc. to IEC 60 Calorific value (MJ/m): 0. (approx.) S IEC Security (Fire behaviour) IEC IEC EFP Grade EFP Grade Performance: Better than category 7 acc. EN 088 and IEC 66 excellent NEXT, excellent screening characteristics (individual and overall screen), low SKEW Bandwidth 900 MHz P > class E > 0 MHz > class E A > 00 MHz Performance (Cabling class, bandwidth) > class F > 600 MHz > class F A >,000 MHz > class G >,00 MHz Applications: Connecting cable and patch cord for generic cabling systems acc. ISO/IEC 80 and EN 07 (. edition). Ideal for all applications of classes D up to F Multimedia (Video, Data, Voice) >0 GbE acc. IEEE 80. an (draft), Cable sharing, VoIP, PoE A > 00 MbE > GbE Application (Ethernet, TV) up to 0 GbE > 0 GbE > 0 GbE TV Mechanical characteristics: Bending radius: during operation: min. x overall diameter Tensile strength: 0 (max.) C AWG 7 AWG 6/ Construction (Conductor size, Tensile strength) AWG AWG AWG Electromagnetic behaviour: Transfer impedance at 0 MHz (mohm/m): (nominal value) Screening attenuation up to,000 MHz (db): 60 (nominal value) Coupling attenuation up to,000 MHz (db): 80 (nominal value) E > 0 db > 0 db EMC (Coupling attenuation) > 60 db > 70 db > 80 db 6

47 Electrical characteristics at 0 C: DC resistance (Ohm/km): 70 (max.) Insulation resistance (Gohm x km): (min.) Mutual capacitance (pf/m): (approx.) Signal velocity (c): 0.78 (approx.) Propagation delay (ns/00m): 0 (approx.) Skew at 00 MHz (ns/00m):. (approx.) Characteristic impedance at 00 MHz (Ohm): 00 ± Test voltage Ueff (V):,000 Operating voltage Ueff (V): (max.) Frequency Attenuation NEXT PS-NEXT ACR PS-ACR EL-FEXT PS-ELFEXT RL MHz db/0m db db db@0m db@0m db@0m db@0m db typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 typ. Cat.7 max.* min.* min.* min.* min.* min.* min.* min.* * EN 088--/IEC 66-6 MegaLine F6-90 S/F flex Chemical characteristics: Free of hazardous substances acc. to RoHS 00/9/EG Certificates and Approvals: Quality mark with production control: Number of registration VDE Link performance: KERPEN ELine systems and further commercial cabling systems Inspection certificate: acc. to DIN respectively EN 00 In agreement to LVD (7//EEC): Thermal characteristics: Temperature range for fixed installation: -0 C up to + 60 C Temperature range for mobile operation: 0 C up to + 0 C Article number Size Overall diameter Weight Copper number Colour sheat mm kg/km kg/km 7KS700 P.7 (approx.) (approx.) 7 grey RAL 70 7KS700 P.7 (approx.) (approx.) 7 yellow, RAL 0 7KS7006 P.7 (approx.) (approx.) 7 green, RAL 608 7KS7007 P.7 (approx.) (approx.) 7 blue, RAL 0 7KS7008 P.7 (approx.) (approx.) 7 red, RAL 000 Package: Drum,000 m 7

48 MegaLine MegaLine E-70 S/F flex S P A C E Type: KS-0YSCH xxawg 7/7 PIMF Construction: Conductor: bare stranded copper wire, AWG 7/7 Insulation: cellular-pe, core-ø: max..0 mm Twisting element: Pair Individual screen: aluminium bonded polyester tape Twisting: pairs Overall screen: tinned copper wire braid Outer sheath: halogen-free, flame retardend compound Conductor Insulation Individual screen Overall screen Outer sheath Printing outer sheath: KERPEN MegaLine E-70 S/F flex P H SPACE CODE Number of registration VDE 808 Production lot code Meter marking Colour code: wh/bu, wh/or, wh/gn, wh/bn Colour outer sheath: grey, RAL 70; yellow, RAL 0; green, RAL 608; blue, RAL 0; red, RAL 000 Fire behaviour: Flame retardance: acc. to IEC 60-- Halogen acid gas emission: acc. to IEC 607- Smoke density: acc. to IEC 60 Calorific value (MJ/m): 0. (approx.) S IEC Security (Fire behaviour) IEC IEC EFP Grade EFP Grade Performance: Better than category 6 acc. EN 088 and IEC 66 very good NEXT, very good screening characteristics (individual and overall screen), low SKEW Bandwidth 700 MHz P > class E > 0 MHz > class E A > 00 MHz Performance (Cabling class, bandwidth) > class F > 600 MHz > class F A >,000 MHz > class G >,00 MHz Applications: Connecting cable and patch cord for generic cabling systems acc. ISO/IEC 80 and EN 07 (. edition). Ideal for all applications of classes D up to E A Multimedia (Video, Data, Voice) up to 0 GbE acc. IEEE 80. an (draft), Cable sharing, VoIP, PoE A > 00 MbE > GbE Application (Ethernet, TV) up to 0 GbE > 0 GbE > 0 GbE TV Mechanical characteristics: Bending radius: during operation: min. x overall diameter Tensile strength: 0 (max.) C AWG 7 AWG 6/ Construction (Conductor size, Tensile strength) AWG AWG AWG Electromagnetic behaviour: Transfer impedance at 0 MHz (mohm/m): (nominal value) Screening attenuation up to,000 MHz (db): 60 (nominal value) Coupling attenuation up to,000 MHz (db): 80 (nominal value) E > 0 db > 0 db EMC (Coupling attenuation) > 60 db > 70 db > 80 db 8

49 Electrical characteristics at 0 C: DC resistance (Ohm/km): 70 (max.) Insulation resistance (Gohm x km): (min.) Mutual capacitance (pf/m): (approx.) Signal velocity (c): 0.78 (approx.) Propagation delay (ns/00m): 0 (approx.) Skew at 00 MHz (ns/00m):. (approx.) Characteristic impedance at 00 MHz (Ohm): 00 ± Test voltage Ueff (V):,000 Operating voltage Ueff (V): (max.) Frequency Attenuation NEXT PS-NEXT ACR PS-ACR EL-FEXT PS-ELFEXT RL MHz db/0m db db db@0m db@0m db@0m db@0m db typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 max.* min.* min.* min.* min.* min.* min.* min.* MegaLine E-70 S/F flex * EN (draft)/en 088--/IEC 66-6 Chemical characteristics: Free of hazardous substances acc. to RoHS 00/9/EG Certificates and Approvals: Quality mark with production control: Number of registration VDE Link performance: KERPEN ELine systems and further commercial cabling systems Inspection certificate: acc. to DIN respectively EN 00 In agreement to LVD (7//EEC): Thermal characteristics: Temperature range for fixed installation: -0 C up to + 60 C Temperature range for mobile operation: 0 C up to + 0 C Article number Size Overall diameter Weight Copper number Colour sheat mm kg/km kg/km 7KS60009 P.7 (approx.) (approx.) 7 grey, RAL 70 7KS6000 P.7 (approx.) (approx.) 7 yellow, RAL 0 7KS600 P.7 (approx.) (approx.) 7 green, RAL 608 7KS600 P.7 (approx.) (approx.) 7 blue, RAL 0 7KS600 P.7 (approx.) (approx.) 7 red, RAL 000 Package: Drum,000 m 9

50 MegaLine MegaLine E- U/F flex S P A C E Type: KS-0YSH xxawg 7/7 PIMF Construction: Conductor: bare stranded copper wire, AWG 7/7 Insulation: cellular-pe, core-ø: max..0 mm Twisting element: Pair Individual screen: aluminium bonded polyester tape Twisting: pairs Outer sheath: halogen-free, flame retardend compound Printing outer sheath: KERPEN MegaLine E- U/F flex P H SPACE CODE Number of registration VDE 808 Production lot code Meter marking Conductor Insulation Individual screen Outer sheath Copper drain wire Colour code: wh/bu, wh/or, wh/gn, wh/bn Colour outer sheath: grey, RAL 70 Fire behaviour: Flame retardance: acc. to IEC 60-- Halogen acid gas emission: acc. to IEC 607- Smoke density: acc. to IEC 60 Calorific value (MJ/m): 0. (approx.) S IEC Security (Fire behaviour) IEC IEC EFP Grade EFP Grade Performance: Better than category 6 acc. EN 088 and IEC 66 very good NEXT, low SKEW Bandwidth 0 MHz P > class E > 0 MHz > class E A > 00 MHz Performance (Cabling class, bandwidth) > class F > 600 MHz > class F A >,000 MHz > class G >,00 MHz Applications: Connecting cable and patch cord for generic cabling systems acc. ISO/IEC 80 and EN 07 (. edition). Ideal for all applications of classes D up to E Multimedia (Video, Data, Voice) up to GbE acc. IEEE 80. ab, Cable sharing, VoIP, PoE A > 00 MbE > GbE Application (Ethernet, TV) up to 0 GbE > 0 GbE > 0 GbE TV Mechanical characteristics: Bending radius: during operation: min. x overall diameter Tensile strength: 0 (max.) C AWG 7 AWG 6/ Construction (Conductor size, Tensile strength) AWG AWG AWG Electromagnetic behaviour: Transfer impedance at 0 MHz (mohm/m): (nominal value) Screening attenuation up to,000 MHz (db): 0 (nominal value) Coupling attenuation up to,000 MHz (db): 60 (nominal value) E > 0 db > 0 db > 60 db > 70 db EMC (Coupling attenuation) > 80 db 0

51 Electrical characteristics at 0 C: DC resistance (Ohm/km): 70 (max.) Insulation resistance (Gohm x km): (min.) Mutual capacitance (pf/m): (approx.) Signal velocity (c): 0.78 (approx.) Propagation delay (ns/00m): 0 (approx.) Skew at 00 MHz (ns/00m):. (approx.) Characteristic impedance at 00 MHz (Ohm): 00 ± Test voltage Ueff (V):,000 Operating voltage Ueff (V): (max.) Frequency Attenuation NEXT PS-NEXT ACR PS-ACR EL-FEXT PS-ELFEXT RL MHz db/0m db db db@0m db@0m db@0m db@0m db typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 max.* min.* min.* min.* min.* min.* min.* min.* * EN 088--/IEC 66-6 MegaLine E- U/F flex Chemical characteristics: Free of hazardous substances acc. to RoHS 00/9/EG Certificates and Approvals: Quality mark with production control: Number of registration VDE Link performance: KERPEN ELine systems and further commercial cabling systems Inspection certificate: acc. to DIN respectively EN 00 In agreement to LVD (7//EEC): Thermal characteristics: Temperature range for fixed installation: -0 C up to + 60 C Temperature range for mobile operation: 0 C up to + 0 C Article number Size Overall diameter Weight Copper number Colour sheat mm kg/km kg/km 7KS60008 P. (approx.) (approx.). grey, RAL 70 Package: Drum,000 m

52 MegaLine MegaLine E-0 U/U flex S P A C E Type: KS-0YSH xxawg /7 Construction: Conductor: bare stranded copper wire, AWG /7 Insulation: cellular-pe Twisting element: Pair Twisting: pairs Outer sheath: halogen-free, flame retardend compound Conductor Insulation Central cross element Outer sheath Printing outer sheath: KERPEN MegaLine E-0 U/U flex P H SPACE CODE Production lot code Meter marking Colour code: whbu/bu, whor/or, whgn/gn, whbn/bn Colour outer sheath: grey, RAL 70 Fire behaviour: Flame retardance: acc. to IEC 60-- Halogen acid gas emission: acc. to IEC 607- Smoke density: acc. to IEC 60 Calorific value (MJ/m): 0.6 (approx.) S IEC Security (Fire behaviour) IEC IEC EFP Grade EFP Grade Performance: Better than category 6 acc. EN 088 and IEC 66 Bandwidth 00 MHz P > class E > 0 MHz > class E A > 00 MHz Performance (Cabling class, bandwidth) > class F > 600 MHz > class F A >,000 MHz > class G >,00 MHz Applications: Connecting cable and patch cord for generic cabling systems acc. ISO/IEC 80 and EN 07 (. edition). Suitable for all applications of classes D up to E up to GbE acc. IEEE 80. ab, VoIP, PoE A > 00 MbE > GbE Application (Ethernet, TV) up to 0 GbE > 0 GbE > 0 GbE TV Mechanical characteristics: Bending radius: during operation: min. x overall diameter Tensile strength: 80 (max.) C AWG 7 AWG 6/ Construction (Conductor size, Tensile strength) AWG AWG AWG Electromagnetic behaviour: Coupling attenuation up to,000 MHz (db): (nominal value) E > 0 db > 0 db > 60 db > 70 db > 80 db EMC (Coupling attenuation)

53 Electrical characteristics at 0 C: DC resistance (Ohm/km): 88 (max.) Insulation resistance (Gohm x km): (min.) Mutual capacitance (pf/m): 0 (approx.) Signal velocity (c): 0.67 (approx.) Propagation delay (ns/00m): 00 (approx.) Skew at 00 MHz (ns/00m): (approx.) Characteristic impedance at 00 MHz (Ohm): 00 ± Test voltage Ueff (V):,000 Operating voltage Ueff (V): (max.) Frequency Attenuation NEXT PS-NEXT ACR PS-ACR EL-FEXT PS-ELFEXT RL MHz db/0m db db db@0m db@0m db@0m db@0m db typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 typ. Cat.6 max.* min.* min.* min.* min.* min.* min.* min.* * EN /IEC 66-6 MegaLine E-0 U/U flex Chemical characteristics: Free of hazardous substances acc. to RoHS 00/9/EG Certificates and Approvals: Quality mark with production control: VDE Link performance: KERPEN ELine systems and further commercial cabling systems Inspection certificate: acc. to DIN respectively EN 00 In agreement to LVD (7//EEC): Thermal characteristics: Temperature range for fixed installation: -0 C up to + 60 C Temperature range for mobile operation: 0 C up to + 0 C Article number Size Overall diameter Weight Copper number Colour sheat mm kg/km kg/km 7KS60007 P 6. (approx.) (approx.) 9. grey, RAL 70 Package: Drum,000 m

54 MegaLine MegaLine D-0 SF/U flex S P 0 A C E Type: KS-0YS(ST+C)H xxawg 6/7 Construction: Conductor: bare stranded copper wire, AWG 6/7 Insulation: cellular-pe, core-ø: max..0 mm Twisting element: Pair Twisting: pairs Overall screen: aluminum-bonded polyester tape and tinned copper wire braid Outer sheath: halogen-free, flame retardend compound Conductor Insulation Overall screen Outer sheath Printing outer sheath: KERPEN MegaLine D-0 SF/U flex P H SPACE CODE 0 Production lot code Meter marking Colour code: whbu/bu, whor/or, whgn/gn, whbn/bn; Colour outer sheath: grey, RAL 70; yellow, RAL 0; green, RAL 608; blue, RAL 0; red, RAL 000 Fire behaviour: Flame retardance: acc. to IEC 60-- Halogen acid gas emission: acc. to IEC 607- Smoke density: acc. to IEC 60 Calorific value (MJ/m): 0.0 (approx.) S IEC Security (Fire behaviour) IEC IEC EFP Grade EFP Grade Performance: Better than category acc. EN 088 and IEC 66 very good screening characteristics Bandwidth 00 MHz P > class E > 0 MHz > class E A > 00 MHz Performance (Cabling class, bandwidth) > class F > 600 MHz > class F A >,000 MHz > class G >,00 MHz Applications: Connecting cable and patch cord for generic cabling systems acc. ISO/IEC 80 and EN 07 (. edition). Ideal for all applications of class D up to GbE acc. IEEE 80. ab, VoIP, PoE A > 00 MbE > GbE Application (Ethernet, TV) up to 0 GbE > 0 GbE > 0 GbE TV Mechanical characteristics: Bending radius: during operation: min. x overall diameter Tensile strength: 60 (max.) C AWG 7 AWG 6/ Construction (Conductor size, Tensile strength) AWG AWG AWG Electromagnetic behaviour: Transfer impedance at 0 MHz (mohm/m): 0 (nominal value) Screening attenuation up to,000 MHz (db): 0 (nominal value) Coupling attenuation up to,000 MHz (db): 6 (nominal value) E > 0 db > 0 db EMC (Coupling attenuation) > 60 db > 70 db > 80 db

55 Electrical characteristics at 0 C: DC resistance (Ohm/km): (max.) Insulation resistance (Gohm x km): 00 (min.) Mutual capacitance (pf/m): 7 (approx.) Signal velocity (c): 0.69 (approx.) Propagation delay (ns/00m): 8 (approx.) Skew at 00 MHz (ns/00m): (approx.) Characteristic impedance at 00 MHz (Ohm): 00 ± Test voltage Ueff (V):,000 Operating voltage Ueff (V): (max.) Frequency Attenuation NEXT PS-NEXT ACR PS-ACR EL-FEXT PS-ELFEXT RL MHz db/0m db db db@0m db@0m db@0m db@0m db typ. Cat. typ. Cat. typ. Cat. typ. Cat. typ. Cat. typ. Cat. typ. Cat. typ. Cat. max.* min.* min.* min.* min.* min.* min.* min.* * EN 088--/IEC 66-6 MegaLine D-0 SF/U flex Chemical characteristics: Free of hazardous substances acc. to RoHS 00/9/EG Certificates and Approvals: Link performance: KERPEN ELine systems and further commercial cabling systems Inspection certificate: acc. to DIN respectively EN 00 In agreement to LVD (7//EEC): Thermal characteristics: Temperature range for fixed installation: -0 C up to + 60 C Temperature range for mobile operation: 0 C up to + 0 C Article number Size Overall diameter Weight Copper number Colour sheat mm kg/km kg/km 7KS00 P. (approx.) (approx.) grey RAL 70 7KS00 P. (approx.) (approx.) yellow, RAL 0 7KS00 P. (approx.) (approx.) green, RAL 608 7KS006 P. (approx.) (approx.) blue, RAL 0 7KS007 P. (approx.) (approx.) red, RAL 000 Package: Drum,000 m

56 MegaLine MegaLine D-0 F/U flex S P 0 A C E Type: KS-0YS(ST)H xxawg 6/7 Construction: Conductor: bare stranded copper wire, AWG6/7 Insulation: cellular-pe, core-ø: max..0 mm Twisting element: Pair Twisting: pairs Overall screen: aluminium bonded polyester tape, metal side inside, with underlayed tinned copper drain wire AWG 6/7 Outer sheath: halogen-free, flame retardend compound Conductor Insulation Overall screen Outer sheath Copper drain wire Printing outer sheath: KERPEN MegaLine D-0 F/U flex P H SPACE CODE 0 Production lot code Meter marking Colour code: whbu/bu, whor/or, whgn/gn, whbn/bn Colour outer sheath: grey, RAL 70 Fire behaviour: Flame retardance: acc. to IEC 60-- Halogen acid gas emission: acc. to IEC 607- Smoke density: acc. to IEC 60 Calorific value (MJ/m): 0.0 (approx.) S IEC Security (Fire behaviour) IEC IEC EFP Grade EFP Grade Performance: Better than category acc. EN 088 and IEC 66 Bandwidth 00 MHz P > class E > 0 MHz > class E A > 00 MHz > class F > 600 MHz > class F A >,000 MHz > class G >,00 MHz Performance (Cabling class, bandwidth) Applications: Connecting cable and patch cord for generic cabling systems acc. ISO/IEC 80 and EN 07 (. edition). Ideal for all applications of class D up to GbE acc. IEEE 80. ab, VoIP, PoE A > 00 MbE > GbE Application (Ethernet, TV) up to 0 GbE > 0 GbE > 0 GbE TV Mechanical characteristics: Bending radius: during operation: min. x overall diameter Tensile strength: 60 (max.) C AWG 7 AWG 6/ Construction (Conductor size, Tensile strength) AWG AWG AWG Elektromagnetisches Verhalten: Transfer impedance at 0 MHz (mohm/m): 80 (nominal value) Screening attenuation up to,000 MHz (db): 0 (nominal value) Coupling attenuation up to,000 MHz (db): 60 (nominal value) E > 0 db > 0 db EMC (Coupling attenuation) > 60 db > 70 db > 80 db 6

57 Electrical characteristics at 0 C: DC resistance (Ohm/km): (max.) Insulation resistance (Gohm x km): 00 (min.) Mutual capacitance (pf/m): 7 (approx.) Signal velocity (c): 0.69 (approx.) Propagation delay (ns/00m): 8 (approx.) Skew at 00 MHz (ns/00m): 8 (approx.) Characteristic impedance at 00 MHz (Ohm): 00 ± Test voltage Ueff (V):,000 Operating voltage Ueff (V): (max.) Frequency Attenuation NEXT PS-NEXT ACR PS-ACR EL-FEXT PS-ELFEXT RL MHz db/0m db db db@0m db@0m db@0m db@0m db typ Cat. typ Cat. typ Cat. typ Cat. typ Cat. typ Cat. typ Cat. typ Cat. max.* min.* min.* min.* min.* min.* min.* min.* * EN 088--/IEC 66-6 MegaLine D-0 F/U flex Chemical characteristics: Free of hazardous substances acc. to RoHS 00/9/EG Certificates and Approvals: Link performance: KERPEN ELine systems and further commercial cabling systems Inspection certificate: acc. to DIN respectively EN 00 In agreement to LVD (7//EEC): Thermal characteristics: Temperature range for fixed installation: -0 C up to + 60 C Temperature range for mobile operation: 0 C up to + 0 C Article number Size Overall diameter Weight Copper number Colour sheat mm kg/km kg/km 7KS0007 P.0 (approx.) 6 (approx.) 6 grey, RAL 70 Package: Drum,000 m 7

58 8ELineTM The ELine PREMIUM system ELine 00 EC7 ELine 00 RJ S ELine 0 RJ S ELine 0 RJ U A combination meeting top requirements ELine adapter clip ELine triple outlet by adapter clip ELine dual outlet The ELine PREMIUM system includes the modular jacks ELine 00 EC7 for multimedia applications, ELine 00 RJ S for Cat. 6 A applications according to the draft.0 standard IEEE 80.an for 0 GbE Ethernet via copper and ELine 0 RJ for Cat. 6 applications in a shielded and an unshielded version. Due to their especially compact design, these high-performance jacks are easy to integrate into high-density racks and wall outlets. In addition to the ELine dual outlet, the ELine triple outlet provides space for up to three modular jacks. Besides the standard ELine -port panel, KERPEN also offers the ELine 8-port panel with double-density capacity on one rack unit only. The product range also includes patch cords tailor-made for the application in question. The ELine PREMIUM range is rounded off by an extensive set of accessories for under-floor installation.

59 ELine ports/ U panel compatible with the PREMIUM series ELine 8 ports/ U panel ELine floorbox adapter (Ackermann, Kleinhuis, Deutsche Elektraplan) ELine ports/ U panel ELine 6 ports/ U panel ELine mini patch 6, 8 and 6 ports ELine TM PREMIUM system Multimedia Class E A / Cat. 6 A Class E / Cat. 6 Class E / Cat. 6 shielded shielded shielded unshielded ELine 00 Article no. ELine 00 Article no. ELine 0 Article no. ELine 0 Article no. EC7 RJ S RJ S RJ U MegaLine cable G-0 S/F 7KS8000 F0-0 S/F 7KS7000 F0-0 S/F 7KS70008 E-0 U/U 7KS6000 SY 7KS06 F0-0 S/F 7KS70008 F6-90 S/F 7KS7000 SY 7KS068 F6-90 S/F 7KS7000 F6-80 S/F 7KS700 F0-0 S/F 7KS7000 E-70 S/F 7KS6000 F6-0 S/F 7KS70008 E-70 F/F 7KS6008 ELine jack EC7 9ZE 00 RJ S 9ZE 0 RJ S 9ZE000 0 RJ U 9ZE0009 ELine outlet dual 9ZE00 dual 9ZE00 dual 9ZE00 dual 9ZE00 (0 x 0) triple 9ZE000 triple 9ZE000 triple 9ZE000 triple 9ZE000 ELine ports U 9ZE000 ports U 9ZE000 ports U 9ZE000 ports U 9ZE000 panel 9 8 ports U 9ZE ports U 9ZE ports U 9ZE ports U 9ZE0008 ELine floorbox holder* GB complete for a maximum of inserts 9ZE6000 floorbox holder* GB complete for a maximum of inserts 9ZE6000 Insert for floorbox holder Insert for floorbox holder (up to jacks) 9ZE60006 ELine EC7-RJ 0.m 9KE000 RJ-RJ.0m 9KWT00 RJ-RJ.0m 9KW600 RJ-RJ.0m 9KW7900 patch cord flex EC7-RJ.0m 9KE000 RJ-RJ.0m 9KWT00 RJ-RJ.0m 9KW600 RJ-RJ.0m 9KW7900 (selection) EC7-RJ.0m 9KE000 RJ-RJ.0m 9KWT00 RJ-RJ.0m 9KW600 RJ-RJ.0m 9KW7900 EC7-RJ.0m 9KE000 RJ-RJ.0m 9KWT00 RJ-RJ.0m 9KW600 RJ-RJ.0m 9KW7900 EC7-RJ.0m 9KE000 RJ-RJ 0m 9KWT00 RJ-RJ.0m 9KW600 RJ-RJ 0 m 9KW7900 * Other floorbox holders on request 9

60 60ELineTM ELine 00 EC7 Multimedia up to. GHz via twisted pairs! If a passive cabling system is connected with the term multimedia, the question which immediately arises is how does that all go together? after all, the term is more well-known in connection with products from entertainment electronics. But ELine 00 EC7 really does manage multimedia, because it allows the parallel use of different media via structured in-house cabling: data, voice, image and even television. ELine 00 EC7 the concept Since the early 990s, KERPEN has been offering 00 Ω data cables of the MegaLine series with individual shielding of each pair. This principle was the model for the chamber system used in the ELine 00 plug connector. There's a method to Multimedia PC Telephone Video/audio/TV/radio The individually shielded chambers, each containing one pair, make the EC7 plug connector an ideal improvement on individually shielded S/FTP cables. data services of Class A to F PC PC PC Cable and plug connector form the ideal symbiosis: pairs = chambers with GHz performance. The advantages are obvious: Consistent separation of the signal paths in an ideally matched system expands the possible applications in unimagined ways. It is thus also possible to use two data services of Class A to F simultaneously via only one cable and one EC7 jack. However, different services such as telephone and data services can also be operated in parallel without the risk of NEXT problems. These possibilities are referred to under the name of cable-sharing or service-sharing. The units are connected via appropriately matched -, - or -pair ELine EC7 work area cords: Mixed telephone/data services Telephone Telephone

61 TV via twisted pairs! The task of transmitting analogue CATV services via twisted pairs is technically very demanding. In order to be able to transmit all channels, transmission frequencies of up to 86 MHz are necessary this demands the utmost in reserve performance of the system and especially good attenuation characteristics. During development, ELine 00 EC7 was optimised especially for this purpose, the current product range providing a wide range of tools for transmitting CATV signals. The world of twisted pairs (00 Ω) is connected to the world of television (7 Ω) via twisted passive work area cords with an integrated balun. In contrast to conventional solutions, outlets can be used flexibly: Thus, from being a telephone or data outlet, EC7 is easy to turn into a TV connection later if necessary. PC/TV/Telephone PC Telephone The reduction in the number of cables and outlets required usually allows reductions in the costs for cable channels, switching cabinets etc. Service-sharing via ELine 00 EC7 allows you to cut costs. Our experience! TV ELine 00 EC7 Economy! There is a price to pay for high-tech and added value. In the long run, it is not necessary for the system to cost more than conventional systems, which usually require a special cable and a special plug connector for each service. ELine 00 EC7 allows you to save up to 0 % of the cables, plug connectors, outlets and patch fields. Multiple use reduces the system costs by between and 0 % (depending on the services used). ELine 00 EC7 includes many innovative new ways of going about things. This is why it could come as a surprise to discover that KERPEN introduced it into the market as early as 996. Since then we have cooperated closely with our customers at all times, so that many of our customers' ideas on adding to or optimising our products have been included into the system concept over the last years. Thus, ELine 00 EC7 now includes a sophisticated system solution which follows the market requirements and is unparalleled at present! As a four-lane data highway, ELine 00 EC7 provides true multimedia to the desk. This is appreciated by customers all over the world we can refer you to a widely installed basis with top references. Why not ask us for our up-to-date list? 6

62 6ELineTM New jack design! The ELine 00 EC7 jack has been completely redesigned. Its robust full-metal design allows it to be integrated completely into the panel and the outlets used for the ELine PREMIUM series. This allows the use of up to EC7 jacks in the PREMIUM outlet and up to 8 ports on one height unit in the switching cabinet! The PREMIUM series also allows the mixed equipping of outlets and panel with the Cat. 6 jacks ELine 0 RJ S and ELine 0 RJ U (mixed-media application). Last but not least, the assembly time is reduced dramatically in comparison with the EC7 jack used up to now! The new jack consists of individual elements only, thus allowing rapid and extremely easy assembly. The completely redesigned ELine 00 EC7 jack makes assembly child's play and further improves performance while leaving the interface unchanged! Backward-compatible! Our multimedia system has been put to widespread use over the years and made many friends. This is why it was especially important for us to keep the system backwardcompatible to the old range although the jack was redesigned: It goes without saying that all patch cords and work area cords ever supplied also fit into the new EC7 jack. Adapter clips allow the retrofitting of existing panels from the old ELine outlet/panel program. More bandwidth, more flexibility with regard to connections, a more reliable future and more unbeatable value for money are not provided by any other system solution! ELine 00 EC7 jack, pair separator from front and strain relief

63 Technical data Compatible outlets/panels etc. See PREMIUM series ELine 00 EC7 (old series) via ELine mounting clip (Article number: 9ZE00) Category Better than Category 7/Class F according to ISO/IEC 80 and EN 07 nd Edition Better than IEC 08 SOHO standard ELine 00 EC7 Jack type EC7 multimedia jack New design: Full metal body -part jack set Shielded Connection method: push-in, gas-tight IDC Shielding: 60 Recommended conductors: AWG /) Colour coding 6

64 ELine TM ELine 00 RJ S a new cabling system for 0 Gigabit Ethernet With ELine 00 RJ S, KERPEN presents a new shielded RJ cabling system specially developed and optimised for the future transmission standard 0 Gigabit Ethernet (IEEE 80.an). In order to improve the signal-to-noise ratio which is critical at 0 GbE, it is also planned to reduce the attenuation and to define the Alien NEXT for the first time with the aim of reducing interference to a minimum. Alien NEXT is the sum of the interference affecting a data pair in a cable A and induced by one or more data pairs in an adjacent cable B. Fig. : The new ELine 00 RJ S jack from KERPEN Fig. : Diagram of Alien NEXT 0 Gigabit Ethernet With a transmission performance 0 times as high as that prescribed by the old,000 BASE T standard, the requirements for cabling systems designed to meet the demands of the future have also increased considerably. The use of shielded cabling is the safest and most economical method of reducing the Alien NEXT to a negligible value. In order to guarantee the transmission of 0 GbE, the relevant cabling committees have agreed on the standardisation of a new Class E A with a bandwidth of 00 MHz. As with ISO/TEC 80 and EN 07 nd Edition, a channel with a length of 00m is to be supported using a maximum number of connector transitions. ELine 00 RJ S performance Although the future cabling standard provides for a bandwidth of 00 MHz, ELine 00 RJ S was evaluated up to a maximum frequency of 6 MHz. Evaluation is based on the channel requirements according to JTC SC N98 a) The NEXT of ELine 00 RJ S has a security reserve of > db up to 00 MHz compared with the limits of Class E. The security reserve is still >db compared with the limits extrapolated up to 00 MHz. 6

65 Fig. : NEXT curve up to 6 MHz b) The RL curve shows excellent homogeneity of the components selected within the ELine 00 RJ S cabling system. ELine 00 RJ S short description Extremely well-matched components are used for ELine 00 RJ S. The jack is an improved version of the ELine 0 RJ S jack. The dimensions have remained unchanged. However, the engine at the heart of it has been optimised once more for frequencies of more than 0 MHz. The refined surface of the housing allowed optimum shield attenuation values to be achieved. The highquality products MegaLine F6-90 S/F and F6-90 S/F flex tested at more than 600 MHz are used as cables. ELine 00 TM RJ S ELine 00 RJ S other highlights in a nutshell Space-saving The components of the ELine 00 RJ S system have especially small dimensions. jacks fit into the space taken up by a conventional dual outlet. A new panel with U provides room for 8 ports. Fig. : RL curve up to 6 MHz c) The ELFEXT of ELine 00 RJ S behaves extremely safely, especially at the limits above 00 MHz. Extremely easy to mount Only three components in one compact high-grade zinc die-cast housing the ELine 00 RJ is easy to mount quickly and safely. The clear colour coding virtually makes mounting errors and the resulting additional costs a thing of the past. The compact ELine 00 RJ S modules can be mounted in panel and outlet from the front and from the back. Fig. : ELFEXT curve up to 6 MHz The measurements were carried out successfully on long cable links (80 m) as well as short ones ( m). Compatible The ELine 00 RJ S is part of the PREMIUM product family and is therefore compatible with the existing ELine 00 EC7 and ELine 0 RJ S components. Economical Easy to mount, designed to meet the demands of the future and priced to suit the market all in all, ELine 00 RJ is a highly economical system with a high degree of investment protection! 6

66 66ELineTM ELine 0 RJ the real Category 6 ELine 0 RJ S (shielded) and ELine 0 RJ U (unshielded) ELine 0 RJ jacks of the PREMIUM system were developed for the highest of demands: Optimum performance, easy assembly and compact design for high packing density make this series unique. In addition, the dimensions of the housing are compatible with the multimedia jack ELine 00 EC7. This ensures problem-free upgrading within the PREMIUM system. ELine 0 RJ: the concept ELine 0 RJ plug connectors are based on completely redesigned plug connections. Extremely short individual contacts and a multilayer circuit board of a very short design are used. The concept makes parallel conductors largely unnecessary, thus minimising coupling between the individual pairs of contacts. The benefits! Space-saving The ELine 0 RJ is very much smaller than conventional RJ plug connectors and provides maximum performance in a small space. The components of the ELine 0 RJ system have especially small dimensions. A triple outlet only takes up the space of a conventional dual outlet. A new panel with HU provides room for /8 ports. Of course, the conventional panels in the ELine system can also be used via mounting clips. Extremely easy to mount! ELine 0 RJ is a convincing solution due to its simple, rapid and flexible (modular) connecting technology. Only three components in one compact zinc die-cast housing the ELine 0 RJ is easy to mount quickly and safely. The clear colour coding virtually makes mounting errors and the resulting additional costs a thing of the past. Protection from incorrect use via RJ, RJ or incorrectly moulded RJ work area cords increases safety. The compact ELine 0 RJ modules can be mounted in panels and outlets from the front and from the back.

67 The fully shielded ELine 0 RJ offer good electromagnetic compatibility and supports EN 0/008. The real Cat. 6! Thanks to the revolutionary design, a worldwide first, ELine 0 RJ goes far beyond all requirements of Class E/Category 6 according to ISO/IEC 80 and EN 07, nd Edition. Measurements and certificates from the accredited test laboratory GHMT prove the excellent electrical characteristics of the system. ELine 0 RJ offers maximum performance even in worst case configurations in a -connector channel and a -connector permanent link. The excellent values for NEXT, ELFEXT and ACR provide maximum headroom in comparison to the standard for all pair combinations up to 0 MHz. The certification of the ELine 0 RJ module according to Category 6 (de-embedded measuring method according to IEC and TIA 86 B.) gives the system the rating 'real Category 6'. What we recommend today: Invest in ELine 0 RJ for standardised Class E cabling with excellent transmission characteristics, for example in connection with MegaLine F6-90 S/F and MegaLine F6-90 S/F flex. Technical data Compatible outlets/panels etc. See PREMIUM series (pages 8 9) Category Better than Category and Category 6 according to ISO/IEC 80 and EN 07 nd Edition for Class D (up to 00 MHz) and Class E (up to 0 MHz) Cat. 6 de-embedded according to EIA/TIA-68-B.- Jack type RJ, Cat. 6 (de-embedded) for 0 MHz performance Shielded (ELine 0 RJ S, Article number 9ZE000) or Unshielded (ELine 0 RJ U, Article number: 9ZE0009) Connecting method: punch-down, gas-tight IDC Recommended conductors: AWG /.. Colour coding Certificates Certified by GHMT* according to: - Class E in a -connector permanent link - Class E in a -connector channel - According to ISO/IEC 80 and EN 07 nd Edition Cat. 6 de-embedded ELine 0 RJ 67

68 ELine TM Jacks, outlets and patch panels Multimedia. GHz ELine 00 EC7 jack 6 x x 6.9 mm (WxHxD) Mounting depth: 0 mm ELine 00 RJ S jack 6 x x 6.9 mm (WxHxD) Mounting depth: 0 mm Product description: Product description: Jack body: zinc die-cast, silver-plated Strain relief: nickel silver Contacts: gold-plated IDC contacts: bronze, tinned Short assembly time Suitable for use in patch panels, floorboxes and outlet inserts of the PREMIUM series Jack body: zinc die-cast, silver-plated Strain relief: nickel silver Contacts: 8-pole RJ jack Short assembly time Suitable for use in patch panels, floorboxes and outlet inserts of the PREMIUM series Article number: 9ZE Pcs. per packing unit: 8 Article number: 9ZE Pcs. per packing unit: 8 ELine 0 RJ S jack 6 x x 6.9 mm (WxHxD) Mounting depth: 0 mm ELine 0 RJ U jack 6 x x 6.9 mm (WxHxD) Mounting depth: 0 mm Product description: Product description: Jack body: fully shielded Strain relief: metal Contacts: 8-pole RJ jack Short assembly time Suitable for use in patch panels, floorboxes and outlet inserts of the PREMIUM series Jack body: fully shielded Strain relief: metal Contacts: 8-pole RJ jack Short assembly time Suitable for use in patch panels, floorboxes and outlet inserts of the PREMIUM series Article number: 9ZE000 Pcs. per packing unit: 8 Article number: 9ZE0009 Pcs. per packing unit: 8 68

69 Jacks, outlets and patch panels Multimedia. GHz Products ELine PREMIUM triple outlet insert 0 x 0 x 0. mm (WxHxD) Mounting depth: mm Inclination: 0 ELine PREMIUM dual outlet insert 0 x 0 x 0. mm (WxHxD) Mounting depth: mm Inclination: 0 Product description: Without components Suitable for mounting in parapet ducts and for surface mounting, concealed mounting and many underfloor systems M thread for earth connection Dust protection cover Delivery without cover frame For up to jacks Compatible with ELine 0 RJ S, ELine 0 RJ U and ELine 00 EC7 jacks Pure white, RAL 900 Product description: Without components Suitable for mounting in parapet ducts and for surface mounting, concealed mounting and many underfloor systems M thread for earth connection Dust protection cover Delivery without cover frame For up to two modules Compatible with ELine 00 EC7, ELine 00 RJ S, ELine 0 RJ S and ELine 0 RJ U Pure white, RAL 900 Article number: 9ZE000 Pcs. per packing unit: 8 Article number: 9ZE00 Pcs. per packing unit: 8 ELine PREMIUM patch panel, U, 8 ports (RJ/EC7) 8 x U x 98 mm (WxHxD) ELine patch panel, U, ports (RJ/EC7) 8 x U x 98 mm (WxHxD) Product description: Without components, takes up a maximum of 8 jacks (including mixed media): ELine 0 RJ S, ELine 0 RJ U, ELine 0 EC7 on one U! Front panel light grey, RAL 70 Snap-in assembly Mounting clip not required Traction relief Earth connection Product description: Without components, takes up a maximum of jacks (including mixed media): ELine 0 RJ S, ELine 0 RJ U, ELine 00 EC7 Front panel light grey, RAL 70 Snap-in assembly Mounting clip not required Traction relief Earth connection Article number: 9ZE0008 Pcs. per packing unit: Article number: 9ZE000 Pcs. per packing unit: 69

70 70ELineTM Patch cords and work area cords (data) wt bl wt gn EC7 back view wt or wt br ELine 00 EC7 patch cord/work area cord Product description: P (7KS089), light grey RAL 70 A end equipped with -pair EC7 plug B end equipped with -pair EC7 plug Assignment: / Colour of bending protection sleeve EC7/EC7: yellow Application: Gigabit Ethernet Article number: 9KEC00 9KEC00 9KEC00 9KEC00 Pcs. per packing unit: EC7 back view wt or bl wt EC7 back view ELine 00 EC7 patch cord/work area cord Product description: P (7KS0068), light grey, RAL70 A end equipped with -pair EC7 plug B end equipped with -pair EC7 plug Colour of bending protection sleeve: light grey, RAL 70 Article number: 9KE m 9KE000.0 m 9KE000.0 m 9KE000.0 m 9KE000.0 m Pcs. per packing unit: wt bl wt gn EC7 back view RJ front view wt bl wt gn ELine 00 EC7 patch cord/work area cord Product description: P (7KS089), light grey RAL 70 A end equipped with -pair EC7 plug B end equipped with RJ plug Assignment EC7-RJ Colour of bending protection sleeve EC7/RJ: yellow Application: Gigabit Ethernet Article number: 9KEC00 9KEC00 9KEC00 9KEC00 Pcs. per packing unit: EC7 back view Article number: 9KEC000 9KEC000 9KEC000 9KEC000 Pcs. per packing unit: wt or bl Open end wt wt bl wt gn Product description: EC7 back view Open end wt bl wt gn ELine 00 EC7 patch cord/work area cord Product description: ELine 00 EC7 patch cord/work area cord P (7KS089), light grey RAL 70 A end equipped with -pair EC7 plug Colour of bending protection sleeve EC7/RJ: yellow B end without components (for self-mounted RJ plug etc.) P (7KS0068), light grey, RAL70 A end equipped with -pair EC7 plug B end unterminated (for self-mounted RJ plug etc.) Colour of bending protection sleeve: light grey, RAL 70 Article number: 9KE m 9KE000.0 m 9KE000.0 m 9KE000.0 m 9KE000.0 m Pcs. per packing unit:

71 Patch cords and work area cords (data) wt EC7 back view or wt bl RJ front view ELine 00 EC7 patch cord/work area cord Product description: EC7 back view wt or bl wt RJ front view ELine 00 EC7 patch cord/work area cord Product description: Accessories P (7KS0068), light grey, RAL70 A end equipped with -pair EC7 plug B end equipped with RJ plug Assignment RJ: /, /6 Colour of bending protection sleeve EC7/RJ: yellow Sticker: Crossover Application: Ethernet crossover P (7KS0068), light grey, RAL70 A end equipped with -pair EC7 plug B end equipped with RJ plug Assignment RJ: /, /6 Colour of bending protection sleeve EC7/RJ: yellow Application: Ethernet Article number: 9KE00 0. m 9KE00.0 m 9KE00.0 m 9KE00.0 m 9KE00.0 m Pcs. per packing unit: Article number: 9KE m 9KE000.0 m 9KE000.0 m 9KE000.0 m 9KE000.0 m Pcs. per packing unit: EC7 back view EC7 back view wt or bl wt wt or bl wt RJ front view ELine 00 EC7 patch cord/work area cord RJ front view ELine 00 EC7 patch cord/work area cord Product description: P (7KS0068), light grey, RAL70 A end equipped with -pair EC7 plug B end equipped with RJ plug Assignment RJ: /, /6 Colour of bending protection sleeve EC7/RJ: blue Application: Token Ring Product description: P (7KS0068), light grey, RAL70 A end equipped with -pair EC7 plug B end equipped with RJ plug Assignment RJ: /, /6 Colour of bending protection sleeve EC7/RJ: green Application: ATM and TP-PMD Article number: 9KE m 9KE000.0 m 9KE000.0 m 9KE000.0 m 9KE000.0 m Pcs. per packing unit: Article number: 9KE m 9KE000.0 m 9KE000.0 m 9KE000.0 m 9KE000.0 m Pcs. per packing unit: 7

72 7ELineTM Patch cords and work area cords (telephone) EC7-P back view br wt EC7-P back view Groove and flattening Groove and flattening ELine 00 EC7 patch cord/work area cord Product description: conductors (7KS08), black A end equipped with -pair EC7 plug B end equipped with -pair EC7 plug Colour of bending protection sleeve: black Application: analog and digital telecommunication systems Article number: 9KE m 9KE700.0 m 9KE700.0 m 9KE700.0 m 9KE700.0 m Pcs. per packing unit: EC7-P back view wt br RJ (/) front view Groove and flattening ELine 00 EC7 patch cord/work area cord Product description: conductors (7KS08), black A end equipped with -pair EC7 plug Colour of bending protection sleeve: black B end equipped with RJ0 plug (/) Application: analog and digital telecommunication systems Article number: 9KE m 9KE m 9KE m 9KE m 9KE m Pcs. per packing unit: EC7-P back view br wt br wt EC7-P Open back endview Groove and flattening Groove and flattening ELine 00 EC7 patch cord/work area cord Product description: conductors (7KS08), black A end equipped with -pair EC7 plug Colour of bending protection sleeve: black B end unterminated (for self-mounted RJ plug etc.) Application: analog and digital telecommunication systems Article number: 9KE m 9KE700.0 m 9KE700.0 m 9KE700.0 m 9KE700.0 m Pcs. per packing unit: EC7-P back view wt 6 br RJ (6/) front view Groove and flattening ELine 00 EC7 patch cord/work area cord Product description: conductors (7KS08), black A end equipped with -pair EC7 plug Colour of bending protection sleeve: black B end equipped with RJ plug (6/) Application: analog and digital telecommunication systems Article number: 9KE m 9KE m 9KE m 9KE m 9KE m Pcs. per packing unit:

73 Patch cords and work area cords(telephone) EC7-P back view wt br RJ front view Groove and flattening ELine 00 EC7 patch cord/work area cord Product description: Accessories conductors (7KS08), black A end equipped with -pair EC7 plug Colour of bending protection sleeve: black B end equipped with RJ plug Application: digital telephony Article number: 9KE m 9KE m 9KE m 9KE m 9KE m Pcs. per packing unit: EC7-P back view Groove and flattening EC7 back view wt br ge gn br wt gn RJ front view ELine 00 patch cord/work area cord RJ front view ELine 00 patch cord/work area cord Product description: conductors (7KS08), black A end equipped with -pair EC7 plug Colour of bending protection sleeve: black B end equipped with RJ plug Application: analog telephony for terminal devices with earth key Product description: conductors (7KS08), black A end equipped with -pair EC7 plug Colour of bending protection sleeve: black B end equipped with RJ plug, without bending protection Assignment RJ = /6, / Application: ISDN Article number: 9KE m 9KE m 9KE m 9KE m 9KE m Pcs. per packing unit: Article number: 9KE m 9KE m 9KE m 9KE m 9KE m Pcs. per packing unit: 7

74 7ELineTM Components for CATV use ELine 00 EC7-CATV work area cord Product description: conductor (7KS007), grey A end equipped with EC7 P plug Colour of bending protection sleeve: black B end equipped with CATV balun 00/7 Ω F plug (slide-on) Additional adapter: F jack to IEC plug Application: CATV cable Article number: 9KE m 9KE000.0 m Pcs. per packing unit: ELine 00 EC7-CATV dual quadruple balun 7/00 Ω (distributor insert) 9 x 6 x 0 mm (WxHxD) Product description: Input: x coax, F jack (7 Ω) Output: x ELine 00 EC7 jack (8xP 00 Ω) Metal housing with cover and mounting thread, also suitable for earth connection When mounted in ELine 00 EC7 distributor: occupies two ports 6 x terminating resistors Application: x quadruple CATV balun function Only in conjunction with ELine patch panel (6 ports) (Article number 9ZE07), see p. 77 additional accessories Article number: 9ZE07 Pcs. per packing unit: ELine 00 EC7-CATV patch cord Product description: conductor (7KS007), grey A end equipped with EC7 P plug B end equipped with EC7 P plug Colour of bending protection sleeve: black Application: CATV patch cord for x quadruple balun etc. Article number: 9KE m 9KE m 9KE m 9KE m 9KE m Pcs. per packing unit: ELine 00 EC7 equalizer Product description: Input: coax, F jack (7 Ω) Output: coax, F jack (7 Ω) Switchable via jumper: 9 db, 8 db, 7 db Article number: 9ZE0 Pcs. per packing unit:

75 Components for telephone use ELine 00 EC7 telephone patch panel 8 x x 06 mm (WxHxD) Mounting depth: 0 mm Accessories Product description: Complete with x ( x ) two-conductor jacks 00 double conductors for operation with up to 00 telephone services on U Rear connections x 8 LSA Punch-down connections on x basic modules Article number: 9ZE0 Pcs. per packing unit: Measuring equipment ELine 00 EC7 measuring adapter pair for Fluke DTX,800 (distributor insert) 9 x 6 x 0 mm (WxHxD) ELine 00 E7 back-to-back plug Product description: Suitable for testing EC7 cabling systems up to Class F (600 MHz), permanent link and channel Measuring tip consists of an EC7 back-to-back plug which can be replaced when worn out Product description: ELine 00 E7 back-to-back plug Plug face: four-pair EC7 on both sides Application: EC7 measuring tip for Class F measurements, for permanent link and channel measuring adapter for Fluke DTX,800 Article number: 9ZE008 Pcs. per packing unit: pair Article number: 9ZE00 Pcs. per packing unit: 7

76 ELine TM Other accessories for ELine 00 EC7 and ELine 0 RJ ELine PREMIUM mini patch panel 7 x 7 x 8 mm (WxHxD) ELine PREMIUM mini patch panel 7 x 7 x 8 mm (WxHxD) Product description: Product description: Closed Without components For mounting on wall, floor or ceiling, in industrial environments etc. 6 dual ports to take up a maximum of 6 ELine 00 EC7 or ELine 0 RJ jacks for mounting with adapter clip (Article number 9ZE0006) Closed Without components For mounting on wall, floor or ceiling in industrial environments etc. 8 dual ports to take up a maximum of 8 ELine 00 EC7 or ELine 0 RJ jacks for mounting with adapter clip (Article number 9ZE0006) Article number: 9ZE006 Pcs. per packing unit: Article number: 9ZE008 Pcs. per packing unit: ELine PREMIUM mini patch panel 8 x 7 x 8 mm (WxHxD) ELine PREMIUM mounting clip 8 x 7 x 8 mm (WxHxD) Product description: Product description: Closed Without components For mounting on wall, floor or ceiling, in industrial environments etc. 6 dual ports to take up a maximum of 6 ELine 00 EC7 or ELine 0 RJ jacks for mounting with adapter clip (Article number 9ZE0006) For mounting ELine 0 RJ, ELine 00 RJ and ELine 00 EC7 jacks to existing patch panels/ outlets from the old ELine range Pure white, RAL 900 Hinged dust protection cover Article number: 9ZE0007 Pcs. per packing unit: Article number: 9ZE00 Pcs. per packing unit: 8 76

77 Other accessories for ELine 00 EC7 and ELine 0 RJ Accessories ELine PREMIUM patch panel, U 8 x x 0 mm (WxHxD) Mounting depth: 8 mm ELine PREMIUM patch panel, U 8 x 88 x 0 mm (WxHxD) Mounting depth: 8 mm Product description: Without components Takes up a maximum of 6 ELine 00 EC7 or ELine 0 RJ jacks for mounting with adapter clip, Article number 9ZE0006 U Light grey, RAL 70 Product description: Without components Takes up a maximum of ELine 00 EC7 or ELine 0 RJ jacks for mounting with adapter clip, Article number 9ZE0006 U Light grey, RAL 70 Article number: 9ZE07 Pcs. per packing unit: Article number: 9ZE08 Pcs. per packing unit: 77

78 78ELineTM Other accessories for ELine 00 EC7 and ELine 0 RJ ELine 00 EC7 bending protection sleeve Product description: For ELine 00 EC7 patch cords and work area cords Reversible fastening Available in different colours for optical coding Article number: 9ZE0069 red 9ZE0070 blue 9ZE007 yellow 9ZE007 green 9ZE007 black 9ZE007 grey Pcs. per packing unit: 0 ELine PREMIUM assembly tool Product description: For simple, safe connection of the jacks ELine 0 RJ S ELine 0 RJ U and ELine 00 EC7 Article number: 9ZE0007 Pcs. per packing unit: ELine 00 EC7 terminator plug Product description: EC7 resistive plug, P, with x 00 Ω terminator resistors Application: Pluggable terminator for ISDN So-Bus networks ELine 00 EC7 Article number: 9ZE00 Pcs. per packing unit:

79 ELine floorbox solutions Floorboxes ELine device adapter ELine floorbox insert ELine floorbox insert Product description: For mounting in ELine floorbox insert (for Ackermann UF system GES other underfloor systems on request!) Mass connection Earth connection Integrated strain relief Adapter made of. mm sheet steel Surfaces electroplated Device adapter for: pcs. ELine 00 EC7 pcs. ELine 00 RJ S pcs. ELine 0 RJ S pcs. ELine 0 RJ U Product description: GES6 insert for a maximum of mounting plates For mounting in Ackermann floorbox GES 6 and TEHALIT floorbox Device cup and locking device made of. mm sheet steel Surfaces powder-coated deep black RAL 900 Self-adhesive marking strips for marking as required Adjustable cable strain relief for up to 9 individual cables/copper. The cable strain relief is not part of the scope of delivery) Dust protection cover for fibre optical (optional) Optionally available mounting plates: FLine x SC duplex FLine x E,000/SC/MTRJ ELine device adapter Dummy cover Product description: GES6 insert for a maximum of mounting plates For mounting in Ackermann floorbox GES 6 and TEHALIT floorbox Device cup and locking device made of. mm sheet steel Surfaces powder-coated deep black RAL 900 Self-adhesive marking strips for marking as required Adjustable cable strain relief for up to 9 individual cables/copper. (The cable strain relief is not part of the scope of delivery) Dust protection cover for fibre optical (optional) Optionally available mounting plates: FLine x SC duplex FLine x E,000/SC/MTRJ ELine device adapter Dummy cover The following system accessories are available: Separate strain relief mm and 6. mm The following system accessory is available: Separate strain relief mm and 6. mm Article number: 9ZE60006 Pcs. per packing unit: Article number: 9ZE6000 Pcs. per packing unit: Article number: 9ZE6000 Pcs. per packing unit: 79

80 80ELineTM The ELine NOVUM system ELine 600 GG + adapter clip ELine 0 MLS RJ Cat. 6, shielded ELine 0 MLU RJ Cat. 6, unshielded ELine 0 MLU and ELine 0 MLS with flexible NOVUM technology ELine wall outlet MLS/MLU (86 x 86 mm) The universal NOVUM technology is a concept for flexibly combining ELine jacks of different power stages with NOVUM outlets and panels. At the centre of the NOVUM series are RJ ELine 0 MLU (unshielded) and ELine 0 MLS (shielded) jacks*. Extremely easy mounting and good performance in conjunction with MegaLine data cables guarantee optimum value for money! * Both models can be mounted in the NOVUM panel and the NOVUM outlets

81 ELine wall outlets MLS/MLU ( x mm) ELine port/u panel GG MLS/MLU ELine wall outlets MLS/MLU (80 x 80 mm) ELine TM NOVUM system Class F / Kat. 7 Class E / Cat. 6 Class E / Cat. 6 shielded shielded ELine 600 GG Article no. ELine 0 RJ Article no. ELine 0 RJ Article no. MLS MLU MegaLine cable SY 7KS06 E-70 S/F 7KS6000 E-0 U/U SY 7KS068 E-70 F/F 7KS6008 E- F/F 7KS600 E- U/F 7KS6000 E-0 F/U 7KS6000 ELine jack GG (Keystone) 9ZE000 MLS (Keystone) 9ZK000 MLU (Keystone) 9ZK0000 ELine German 0 x 0 mm 9ZE000 german 80 x 80 mm 9ZK0000 german 80 x 80 mm 9ZK0000 outlet p 0 x 0 mm p flat 0 x 0 mm p flat german 80 x 80 mm 9ZK0000 german 80 x 80 mm 9ZK x 0 mm p º 0 x 0 mm p º french 80 x 80mm 9ZK000 french 80 x 80mm 9ZK000 x mm p flat x mm p flat french 80 x 80 mm 9ZK0000 french 80 x 80 mm 9ZK0000 x, mm p flat x, mm p flat GB 86 x 86 mm 9ZK00007 GB 86 x 86 mm 9ZK x 60 mm p flat 0 x 60 mm p flat GB 86 x 86 mm 9ZK00006 GB 86 x 86 mm 9ZK x 60 mm p º 0 x 60 mm p º ELine panel 9", U, Port 9ZK000 9", U, Port 9ZK000 9", U, Port 9ZK000 (Keystone) ELine patch cord GG-GG m 9KN000 RJ-RJ m 9KW600 RJ-RJ m 9KW7900 (selection) GG-GG m 9KN000 RJ-RJ m 9KW600 RJ-RJ m 9KW7900 GG-GG m 9KN000 RJ-RJ m 9KW600 RJ-RJ m 9KW7900 GG-GG m 9KN000 RJ-RJ m 9KW600 RJ-RJ m 9KW7900 GG-GG 0 m 9KN000 RJ-RJ 0 m 9KW600 RJ-RJ 0 m 9KW7900 8

82 8ELineTM ELine 600 GG two in one: Cat. 6 and Cat. 7 now up to,000 MHz ELine 600 GG: the concept At the heart of the GG concept is the snap-in connector. For the development of the GG, four new contacts for Cat. 7 transmission were added to the RJ. These are activated via a switch mechanism in the jack. The GG jack thus has the first ever switching mechanism for passive cabling. In conjunction with the GG plug, transmission up to,000 MHz is possible on the outer contacts with a suitable cable. This transmission bandwidth ensures that applications of the future F A class can also be transmitted. The GG plug activates the switch via a spacer on the front which activates the new contacts responsible for Cat. 7 transmission. Class E 8 contacts 00 % compatible with RJ new contacts for 600 MHz Class F When the RJ is snapped in, the usual 8 contacts are activated and 00, 0 or 00 MHz are transmitted depending on the cable used. The integrated switch is extremely robust and reliable mechanically. Even after over,00 plug-in cycles (RJ onto new contacts), there is virtually no wear on the switch. The RJ leaves no plastic deposits in the jack and does not affect performance in any way. Two in one: Cat. 6 and Cat. 7! As a two-in-one connector (complete RJ and new 600 MHz interface), GG is fully backward-compatible and meets all requirements of Categories, 6 and 7. If you invest in ELine 600 GG for Class E and F today, considerable savings are guaranteed in comparison with other Class F cabling: For patch and work area purposes, you can for example continue to use the conventional RJ patch cords/work area cords. If necessary, you can then successively invest in Category 7 patch cords/work area cords. GG is a registered trademark of Nexans HQ, Paris

83 A secure future and backward compatibility! ELine 600 GG allows economical migration from Cat. e and 6 to Cat. 7 by simply replacing the patch cords. This makes the decision for later Class F cabling a justin-time investment: the performance is not paid for until it is required! Compatibility matrix Jack Plug Cable Performance of channel GG GG,000 MHz,000 MHz GG GG 0 MHz 0 MHz GG RJ 00 MHz 0 MHz (depending on quality of RJ) RJ GG 600 MHz Not compatible With the two system cables MegaLine SY (AWG ) and SY (AWG ), KERPEN offers two system cables specially designed for this connector which make it much easier to install. Optimum performance certified Measurements by the Gesellschaft für Hochfrequenztechnik GHMT (association high-frequency measuring technology) prove the excellent electrical performance of ELine 600 GG systems for Class E and F. Even in the worst-case configuration with connectors, the system provides real Cat. 6 and Cat. 7 respectively and high NEXT reserves. Who needs Class E and F? ELine 600 GG Flexibility of use only with panels and outlets of the NOVUM series! The choice is yours: The ELine 600 GG jack can be mounted into the specially designed GG patch panel and in outlet inserts or integrated into the NOVUM series via an adapter clip. Easy assembly in standard environments The GG is integrated into standard technology and can be used with standard components like a standard cover frame and standard floorboxes. The installation is based on existing technology and can be used like Cat. and Cat. 6 installations. The EMC covers on the back of the connector ensure optimum EMC protection via 60 shielding. If it's a secure future and reserve performance you're after, the answer is obvious: everybody does! One look at the current standardisation shows that Cat. /Class D is being phased out. Use for,000base-tx specified in draft standard 67- of ANSI TIA/EIA-8 requires a Class E cabling. In contrast to the Gigabit Ethernet standard,000base-t used up to now, this standardisation project includes only pairs each for transmitting and receiving, i.e. it allows a considerable reduction in the Gigabit Ethernet cards required ( low-cost Gigabit Ethernet ). Cell-based,000 Mbit/s (CBG), the use specified by the ATM Forum in af-phy-06000, is not supported by Class D/Cat. cabling. Applications requiring Class F are also planned. Key word: Standardisation for TP and Fibre Channel via Class F (ISO/IEC CD 6-). However, the largest project of all is 0 GbE via copper: IEEE 80.an is to support 0 GbE via Class F (00 m). 8

84 8ELineTM Class F and multimedia The GG is at present designed for connecting information technology at the workplace. The concept will be expanded in future to include additional products in order to allow multimedia applications. Conclusion: The ELine 600 GG cabling system offers considerable advantages and potential savings: When you first take it into operation, you can connect reasonably priced RJ patch cords to the GG jack. If more performance is expected of the LAN in later years, you can upgrade the system to a Class F system by simply replacing the RJ patch cords by GG patch cords. The advantage of this upgrading method is that it can be carried out by the network operator himself. The purchase cost is reduced via just-in-time invest- NEXT in db NEXT Class E Pins -6 Pins - Frequenz in MHz Pins -78 Pins 6-78 Pins 6- Pins -78 Limit nach Klasse E, Channel ments (work area cords). And you get the security which only a product standardised worldwide provides! Excellent electrical performance is guaranteed, even in worst case configurations. A cabling system remains in a building for an average of years. It is impossible to foresee today what new demands will be made on networks during this period. If it's economy and a secure future you're looking for, you should invest in Class F right away. Today we recommend that you invest in ELine 600 G for a Class E and F cabling, for example in conjunction with the MegaLine SY and SY GG system cable! NEXT Class F Pins -6 Pins - Frequenz in MHz Pins -78 Pins 6-78 Pins 6- Pins -78 Limit nach Klasse F, Channel

85 Technical data Compatible outlets/panels etc NOVUM (see p. 80 8) and ELine 600 GG Category Mode : Cat. 6 IEC FJ up to 0 MHz Mode : Cat. 7 IEC up to 600 MHz ELine 600 GG Jack type GG, Cat. 7 backward-compatible to RJ plug connectors Article number: 9ZE000 Connecting technology: punch-down, gas-tight IDC System cable Recommended system cable: MegaLine SY Article number: 7KS06 MegaLine SY Article number: 7KS068 Certificate GHMT certificate for RJ Mode Category 6/Class E GHMT certificate for GG Mode Category 7/Class F 600 8

86 86ELineTM Technical data Compatible outlets/panel etc. ELine outlet inserts MLS/MLU ELine panel MLS/MLU Jack type RJ, Cat. 6 (mated) for 0 MHz performance Shielded (ELine 0 MLS, Article number: 9ZK000) or Unshielded (ELine 0 MLU, Article number: 9ZK0000) Connection method: 0 type punch-down, gas-tight Recommended conductors: AWG / AWG Colour coding according to 68A and 68B Certificates ETL certified according to Cat. 6 (mated link) UL certified according to EIA/TIA-68-A- (UL/cUL 86 listed)

87 Jacks Category 6/7 0/,000 MHZ Products ELine 600 GG jack (individual module) 7 x 0 x mm (WxHxD) Mounting depth: mm ELine 0 MLS RJ jack, shielded Product description: Snap-in jack for use in panels/outlet inserts of the following series: ELine 600 GG or NOVUM via adapter clip Incl. keystone clip Product description: Shielded 8-pole RJ jack Suitable for use in patch panels and outlet inserts of the NOVUM series (see page 88 89) Category 6 Article number: 9ZE000 Pcs. per packing unit: 8 Article number: 9ZK000 Pcs. per packing unit: ELine 0 MLS RJ jack, unshielded Product description: Shielded 8 pole RJ jack Suitable for use in patch panels and outlet inserts of the NOVUM series (see page 88-89) Category 6 Article number: 9ZK0000 Pcs. per packing unit: 87

88 88ELineTM Jacks, outlets and patch panels Category 6/7 0/600 MHz ELine NOVUM patch panel, ports 8 mm (= 9") x mm x 0 mm (WxHxD) Product description: For a maximum of x GG or x RJ MLS/MLU or mixed media Front panel: light grey RAL 70 Extremely easy to mount Traction relief on back Can be earthed via screw connection Article number: 9ZK000 Pcs. per packing unit: ELine 600 GG dual outlet insert, long 0 x 0 x 0 mm (WxHxD) Mounting depth: mm Inclination: Product description: Without components For concealed and underfloor mounting Can be equipped with up to ELine 600 GG jacks, screwless mounting of jacks Connecting point for an additional terminal clamp for traction relief or earthing Suitable for 0 x 0 frames Pure white, RAL 900 Scope of delivery: central panel (0 x 0), snap-in mounting ring, marking window (delivery without cover frame) Article number: 9ZE000 Pcs. per packing unit: 8 ELine 600 GG patch panel, ports x 6 9", U, 80 x x mm (WxHxD) Mounting depth: mm Product description: Without components Steel design, can be equipped with up to ELine 600 GG outlets, x sextuple mounting clips, snap-in assembly of outlets, clip-on cable guide with large-surface shield contacting, insertable marking strips, front panel Scope of delivery: Modular patch panel, marking strips Colour: light grey, RAL 70 Article number: 9ZE00, fixed 9ZE000, telescopic Pcs. per packing unit: ELine 600 GG dual outlet insert, short 0 x 0 x 0 mm (WxHxD) Mounting depth: mm Inclination: Product description: Without components For concealed and cable duct mounting Can be equipped with up to ELine 600 GG jacks, screwless mounting of jacks Suitable for mm round hole frames and 0 x 0 frames Pure white, RAL 900 Scope of delivery: central panel (0 x 0), snap-in mounting ring, marking window (delivery without cover frame) Article number: 9ZE000 Pcs. per packing unit: 8

89 Jacks, outlets and patch panels Accessories ELine 0 ML dual outlet insert 86 x 86 mm (WxH) ELine 0 ML dual outlet insert 80 x 80 mm (WxH) Product description: For a maximum of x RJ ELine MLS (9ZK000) or x RJ ELine MLU (9ZK0000) or mixed media Pearl white, RAL 906 Product description: For a maximum of x RJ ELine MLS (9ZK000) or x RJ ELine MLU (9ZK0000) or mixed media Pure white, RAL 900 models: Article number: 9ZK00006 Pcs. in packing unit: 90 Article number: 9ZK00007 Pcs. in packing unit: models: Article number: 9ZK0000 Pcs. in packing unit: 90 Article number: 9ZK0000 Pcs. in packing unit: 0 ELine 0 ML single outlet insert x mm (WxH) ELine 0 ML single module for outlet insert. x mm (WxH) Product description: For a maximum of x RJ ELine MLS (9ZK000) or x RJ ELine MLU (9ZK0000) Pure white, RAL 900 Product description: ELine single outlet insert for dual outlet x RJ ELine MLS (9ZK000) or x RJ ELine MLU (9ZK0000) Pure white, RAL 900 Model: 90 Article number: 9ZK000 Pcs. in packing unit: Model: 90 Article number: 9ZK0000 Pcs. in packing unit: 89

90 90ELineTM Jacks, outlets and patch panels ELine 600 GG Cat. 7 patch cord/work area cord Product description: P (ML F6-90 S/F flex, 7KS700 A end equipped with -pair GG plug B end equipped with -pair GG plug Assignment: / Colour of bending protection sleeve GG/GG: black Application: Cat. 7 services Article number: 9KN000.0 m 9KN000.0 m 9KN000.0 m 9KN000.0 m Pcs. per packing unit: ELine 0 ML assembly tool Product description: For simple, safe connection of the jacks ELine 0 RJ MLS/MLU Article number: 9ZK00009 Pcs. per packing unit: ELine 600 GG assembly tool Product description: Assembly tool or simple, safe moulding of the ELine 600 GG jack Article number: 9ZKE0006 Pcs. per packing unit:

91 Accessories 9

92 9ELineTM The ELine FIXUM system ELine 0 RJ FS Cat. 6 LSA solution ELine 0 RJ FS Panel, ports, Cat. 6 ELine 0 RJ FU Telephone panel, 0 ports, Cat. ELine 0 RJ FU Telephone panel, ports, Cat. ELine 0 RJ FS Dual outlet, Cat. 6 ELine 0 RJ FS offers good performance with reserves exceeding the Cat. 6 specification in the channel and in the permanent link. In addition, the components are manufactured according to the well-known LSA method, making them extremely easy to mount.

93 LSA products ELine 0 RJ FIXUM panel, ports, shielded 9", U 8 x x 98 mm (WxHxD) ELine 0 RJ FIXUM dual outlet, shielded 80 x 80 mm ELine TM FIXUM Product description: -port RJ panel, shielded, Cat. 6 Rear connection via 8-pole LSA punch-down connection strips Suitable for solid conductors AWG -6 Short assembly time Suitable for mounting in 9" cabinets Colour: pure white, RAL 70 Product description: Outlet for cable duct, surface, concealed and floorbox mounting Two RJ slots, Cat. 6 Rear LSA punch-down connections suitable for solid conductors AWG -6 Colour coding according to EIA / TIA 68 A + B Short assembly time Article number: 9ZE7000 Pcs. per packing unit: Cable guide right/left Cable guide right/left Article number: 9ZE7000 (RAL 900) Article number: 9ZE7000 (RAL 0) Pcs. per packing unit: Pcs. per packing unit: Cable guide top/bottom Cable guide top/bottom Article number: 9ZE70006 (RAL 900) Article number: 9ZE70007 (RAL 0) Pcs. per packing unit: Pcs. per packing unit: ELine FIXUM telephone patch panel, 0 ports 9", U 8 x x 9 mm (WxHxD) Product description: Suitable for ISDN applications Connections: front: 0 x RJ jacks, unshielded Rear: x 0 LSA punch-down connections Connection method: punch-down connections suitable for solid conductors up to AWG Assignment: pin,,, 6 Colour: light grey, RAL 70 ELine FIXUM telephone patch panel, ports 9", U 8 x x 9 mm (WxHxD) Product description: Suitable for ISDN applications Connections: front: x RJ jacks, unshielded Rear: x LSA punch-down connections Connection method: punch-down connections suitable for solid conductors up to AWG Assignment: pin,,, 6 Colour: light grey, RAL 70 Article number: 9ZE7000 Pcs. per packing unit: Article number: 9ZE7000 Pcs. per packing unit: 9

94 9ELineTM Acceptance tests for ELine cabling systems The acceptance tests for ELine cabling systems are carried out according to the requirements of ISO/IEC 80 / EN 07, nd Edition, for channels and permanent links. Further standards related to acceptance tests (execution of tests): DIN EN 06 and DIN EN 69 Channel Class F Frequency/MHZ Attenuation/dB Near-end cross-talk attenuation/db PS NEXT/dB ACR/dB PS ACR/dB ELFEXT/dB PS ELFEXT/dB Reflection attenuation/db Asymmetry attenuation/db Time delay/µs Time delay difference/µs Channel Class E Max. loop resistance ohm Max. loop resistance asymmetry 0.7 ohm Frequency/MHZ Attenuation/dB Near-end cross-talk attenuation/db PS NEXT/dB ACR/dB PS ACR/dB ELFEXT/dB PS ELFEXT/dB Reflection attenuation/db Asymmetry attenuation/db Time delay/µs Time delay difference/µs Max. loop resistance ohm Max. loop resistance asymmetry 0.7 ohm

95 In situ measurement according to Class F In order to guarantee customer satisfaction, in-situ measurement is becoming more and more important for the approval of a system after installation. Customers who have installed a high-quality Class F system are increasingly demanding proof that the promised specifications are complied with over the entire frequency range of Class F up to 600 MHz as an expression of the high quality of their systems. With the two systems ELine 00 and EC7 and ELine 600 GG, KERPEN offers not one but two cabling platforms suitable for Class F. State-of-the-art in-situ measurement techniques are used for approval measurements and certifications according to Class F. In the field of Class F insitu measuring, KERPEN works with the manufacturers Ideal and Fluke in order to measure the performance in the permanent link and in the channel. Measuring instruments from both manufacturers can also be used with their RJ adapters for measuring according to Draft Class E A. Standard Class F acceptance testing according to ISO/IEC 80 and EN 07 up to 600 MHz: Recommended measuring instruments and adapters: IDEAL LANTEK 7G (ELine 00 EC7 Fluke and ELine 600 GG adapters available from IDEAL Ind.) Fluke DTX,800 (ELine 00 EC7 adapter available from KERPEN, Article number 9ZE008) Acceptance tests IDEAL Fluke Fluke DTX,800 Ideal Industries LANTEK 7G Measuring adapter for the ELine 00 EC7 cabling system: Measuring adapter for the ELine 600 GG cabling system: In the acceptance testing of a GG cabling system according to Class F, separate Class E testing of the RJ contacts is no longer necessary as full testing of the jacks is carried out by the manufacturer. 9

96 96ELineTM A selection of measuring instruments (examples): Fluke DSP 00 Acceptance testing ELine 0 RJ S ELine 0 RJ U ELine 0 MLS ELine 0 MLU ELine 0 MLU ELine 0 FIXUM Standard acceptance testing up to 0 MHz Acceptance testing according to Class E 0 MHz permanent link Recommended measuring instruments (as of May 00): Fluke: OMNIscanner, OMNIscanner, DSP 00, DSP 00 or DSP 000, DIX,800 IDEAL: LANTEK 7, LANTEK 6 (Information on other recommended measuring instrument on request) For user information please go to: Fluke OMNIScanner IDEAL Industries LANTEK 7

97 Acceptance tests 97

98 98GigaLine GigaLine enhanced fibre optic technology The increasing degree of automation in industry and the rising information density in office communication make increasing demands on the transmission of analog and digital data. Conventional links based on copper cables are now often reaching the limits of their capacity. The problems caused by electromagnetic effects, differences in potential and operation in explosive environments require technical and economical solutions. The use of GigaLine fibre optic cables solves these problems more reliably than the use of conventional copper cables. The special advantages of GigaLine fibre optic cables make them suitable in the following cases: When electromagnetic effects can occur When reliable potential separation is required When low attenuation and thus long channels are necessary When crosstalk must not occur. When sparks must not form (for explosive environments) When low weight and small dimensions are an advantage When increase security against tapping is required KERPEN GigaLine means a comprehensive delivery program for fibre optic cables for virtually all applications. Besides easy-to-assemble internal cables with compact wire technology for the patch and floor area, universal cables for the backbone indoors and outdoors and the classical outdoor cables for LAN/MAN and WAN, KERPEN offers manufacturing options for a large number of additional designs such as GigaLine outdoor cables with a corrugated steel sheath, a steel band or SWA armour or with an additional lead covering as a protection against chemicals. Gigabit and 0Gigabit Ethernet: new demands on the quality of the fibre optic cabling Improved multimode fibres for Gigabit Ethernet ( OMe ) Gigabit Ethernet in the backbone of structured in-house cabling is now often a reality or is soon to be implemented. The corresponding standard IEEE 80.z was made official as early as July 998. As a consequence of the requirements this entails, since the beginning of this year GigaLine has been delivered with improved multimode fibres. The process used to manufacture the fibres has been optimised in such a way that the profile of the multimode fibre is extremely precise and disturbances in the fibre core are virtually eliminated. As differential mode delay does not occur under these circumstances, mode-conditioning patch cords are not necessary. For more than five years now, the standard versions of GigaLine fibre optic cables with an improved multimode fibre G0/ have provided bandwidth/distance products of 600 MHz x km in the first window and,00 MHz x km in the second window as well as Gigabit Ethernet segment lengths of 70 /,000 m.

99 Improved multimode fibres for 0 Gigabit Ethernet (OM, OMe ) Just a few months after publication of this standard, IEEE started work on the next stage of development with a higher speed: 0 Gigabit Ethernet. The draft of this new 0 Gigabit Ethernet standard was ratified as early as June 00. The official standard was also published by the IEEE in autumn 00. This higher maximum degree of utilisation of the OSe fibre is achieved by reducing the OH peak usual for single-mode fibres up to now, an attenuation peak at,8 nm. Typical attennation curve GigaLine The development of a 0 µm multimode fibre for 0 GbE applications up to 00 m and optimised for 80 nm lasers was also successful. This type of fibre was not only given a standard of its own (OM) in the nd Edition of the cabling standard EN 07 it was also included in the GigaLine product program as early as spring 00. However, development continues even with the newly developed OM fibre. In many cases, the distances to be bridged in the backbone exceed the 00 m possible with a standard OM fibre. For this field of application, KERPEN has been offering GigaLine fibre optic cables with further improved OMe fibres since November 00. These fibres offer optimum conditions for transmitting 0 GbE at segment lengths of up to 0 m. This allows the economical implementation of 0 GbE in the backbone of a building in virtually all possible cases. These fibres allow the use of CWDM (Coarse Wavelength Division Multiplex), a method for the parallel transmission of different wavelengths with a channel separation of 0 nm in the so-called E band (,60,60 nm). The minimum demands made on these improved singlemode fibres with a reduced OH peak are defined in IEC B. / ITU G.6.C/G.6.D (International Telecommunication Union). Among other requirements, the fibre attenuation must be < 0. db/km over the entire wavelength range. Improved single-mode fibres for increased transmission capacity ( OSe /OS) In order to bridge even longer distances, since November 00 KERPEN has complemented the GigaLine fibre optic cables with high-quality multimode fibres of the categories OMe, OM and OMe by also offering GigaLine cables with improved single-mode fibres of the category OSe. Besides the maximum possible 0 Gigabit Ethernet segment lengths of 0 / 0 km, KERPEN GigaLine cables with OSe fibres also offer an increased transmission capacity via a higher maximum degree of utilisation of the fibre. With attenuation values of 0.6 db/km at,0 nm and 0. db/km at 0 nm, KERPEN GigaLine cables with OSe fibres are far below these maximum values. Thus, at 0 nm these fibres also provide a more than 0 % longer range than the standard fibres used up to now. Even today, the KERPEN OSe fibre quality meets the requirements discussed in the draft standards pren07 for the future definition of an OS fibre. Conclusion: The control of the data flows of the future therefore requires maximum care in the planning and execution of the passive network infrastructure. One important aspect here is the selection of the suitable fibre type and quality! 99

100 GigaLine Comparison of the transmission characteristics of KERPEN GigaLine with the requirements of the standard: Comparison between fibre category OM and KERPEN GigaLine G6./ OMe 80 nm,00/0 nm Requirements of standard KERPEN GigaLine Requirements of standard KERPEN GigaLine Attenuation. db/km.0 db/km. db/km 0.7 db/km Bandwidth/length product 00 MHz x km 0 MHz x km 00 MHz x km 800 MHz x km Gigabit Ethernet segment length 7 m 00 m 0 m,000 m 0 Gigabit Ethernet segment length m 6 m 00 m 0 m Comparison between fibre category OM and KERPEN GigaLine G0/ OMe 80 nm,00/0 nm Requirements of standard KERPEN GigaLine Requirements of standard KERPEN GigaLine Attenuation. db/km. db/km. db/km 0.7 db/km Bandwidth/length product 00 MHz x km 600 MHz x km 00 MHz x km,00 MHz x km Gigabit Ethernet segment length 0 m 70 m 0 m,000 m 0 Gigabit Ethernet segment length 8 m 0 m 00 m 900 m Comparison between fibre category OM and KERPEN GigaLine G0/ OM 80 nm,00/0 nm Requirements of standard KERPEN GigaLine Requirements of standard KERPEN GigaLine Attenuation. db/km. db/km. db/km 0.7 db/km Bandwidth/length product,00 MHz x km,00 MHz x km 00 MHz x km 00 MHz x km Laser bandwidth,000 MHz x km,000 MHz x km Gigabit Ethernet segment length 0 m 900 m 0 m 0 m 0 Gigabit Ethernet segment length 00 m 00 m 00 m 00 m Comparison between fibre category OM and KERPEN GigaLine G0/ OMe 80 nm.00/0 nm Requirements of standard KERPEN GigaLine Requirements of standard KERPEN GigaLine Attenuation. db/km. db/km. db/km 0.7 db/km Bandwidth/length product,00 MHz x km,00 MHz x km 00 MHz x km 00 MHz x km Laser bandwidth,000 MHz x km,700 MHz x km Gigabit Ethernet segment length 0 m,000 m 0 m 0 m 0 Gigabit Ethernet segment length 00 m 0 m 00 m 00 m Comparison between fibre category OS and KERPEN GigaLine E9 0/ OSe 0 nm 0 nm Requirements of standard KERPEN GigaLine Requirements of standard KERPEN GigaLine Attenuation.0 db/km 0.6 db/km.0 db/km 0. db/km Attenuation at 8 nm not defined 0. db/km 0 Gigabit Ethernet segment length 0,000 m 0,000 m 0,000 m 0,000 m 00

101 GigaLine Fibre optic indoor cables GigaLine DX 00, 00, 6 GigaLine DXO 00, 00, 6 GigaLine AT 00, 00, 6 GigaLine M 00, 00, 6 Easy plug assembly and good splicing behaviour are the characteristics of GigaLine indoor cables. In the standard version, all designs of indoor cables are supplied with a halogen-free outer sheath compound. GigaLine indoor cables are flame-retardant according to IEC 60-- and usually also according to IEC FO indoor cables They also have the following characteristics: High flexibility Excellent resistance to transverse and longitudinal stress and to thermal stress High tensile strength 0

102 0GigaLine GigaLine DX 00 GigaLine DX 00 GigaLine DX 6 Fibre optic indoor cables (duplex figure 8) KL-J-V(ZN)H G/E Structure: Two compact wires in a figure 8 sheath with a separator and strain relief. Sheath: halogen-free compound Field of application: Work area/patch cords, suitable for direct plug mounting and splicing Dimensions Outer Ø Weight Tensile Transverse compression Fire load Article number Sheath colour strength strength permanent short-term mm kg/km N N/cm N/cm MJ/m kwh/m (approx.) (approx.) (approx.) (approx.) (approx.) (approx.) (approx.) G0/.8x (x0) DA000 orange G0/ OM.8x (x0) DA000 orange G6./.8x (x0) DB7000 orange E9 0/.8x (x0) DC700 yellow GigaLine DXO 00 GigaLine DXO 00 GigaLine DXO 6 Fibre optic ndoor cables (duplex figure 0) KL-J-V(ZN)H G/E Structure: Two individual cables with strain relief (Ø. mm; compact wires in inner sheath) in parallel under an outer sheath. Sheath: halogen-free compound Field of application: Floor cabling, suitable for direct plug mounting and splicing Dimensions Outer Ø Weight Tensile Transverse compression Fire load Article number Sheath colour strength strength permanent short-term mm kg/km N N/cm N/cm MJ/m kwh/m (approx.) (approx.) (approx.) (approx.) (approx.) (approx.) (approx.) G0/.x (x00) DA00 orange G0/ OM.x (x00) DA00 orange G6./.x (x00) DB700 orange E9 0/.x (x00) DC7000 yellow

103 GigaLine AT 00 GigaLine AT 00 GigaLine AT 6 Fibre optic indoor cables, splittable (breakout cables) KL-AT-V(ZN)HH n G/E Structure: Up to individual cables with strain relief (Ø. mm; compact wires in inner sheath) stranded under an outer sheath. Sheath: halogen-free compound, colour: yellow Field of application: Floor cabling, suitable for direct plug mounting and splicing FO indoor cables Dimen- Outer Weight Tensile Transverse Fire load Article number sions ø strength compression strength permanent short-term G 0/ G 0/ OM G 6./ E 9 0/ mm kg/km N N/cm N/cm MJ/m kwh/m (approx.) (approx.) (approx.) (max.) (max.) (approx.) (approx.) G/E 7.0 6, BA000 8BA000 8BB7000 8BC G/E 8. 66, BA000 8BA000 8BB7000 8BC G/E 9.6 8, BA000 8BA000 8BB7000 8BC G/E., BA000 8BA000 8BB7000 8BC7000 G/E., BA0006 8BA0006 8BB BC70006 GigaLine M 00 GigaLine M 00 GigaLine M 6 Fibre optic indoor cables, (multi) KL-J-V(ZN)H n G/E Structure: Up to individual cables stranded under an outer sheath, with common strain relief. Sheath: halogen-free compound, colour: yellow Field of application: Floor cabling, suitable for direct plug mounting and splicing. Dimen- Outer Weight Tensile Transverse Fire load Article number sions ø strength compression strength permanent short-term G 0/ G 0/ OM G 6./ E 9 0/ mm kg/km N N/cm N/cm MJ/m kwh/m (approx.) (approx.) (approx.) (max.) (max.) (approx.) (approx.) G/E MA000 8MA000 8MB7000 8MC G/E MA000 8MA000 8MB7000 8MC G/E MA000 8MA000 8MB7000 8MC G/E MA000 8MA000 8MB7000 8MC7000 G/E MA0006 8MA0006 8MB MC

104 0GigaLine GigaLine Fibre optic universal cables GigaLine DQ 00, 00, 6 U GigaLine universal cables can be used for house leadins without additional transfer points: universal and they cut costs. GigaLine universal cables can be used outdoors and indoors, especially in the case of increased mechanical requirements. Equipped with a metal-free rodent protection made of glass fibres. Another guarantee of safety: flame-retardant according to IEC GigaLine DQ 00, 00, 6 Uc In addition to the features listed above, this version is suitable for direct underground installation.

105 GigaLine DQ 00 Uc Fibre optic universal cable, longitudinally watertight, with metal-free rodent protection KL-U-DQ(ZNS)Hc n x m G0/ OMe Structure: Filled loose tube, central or stranded, water blocking tape, metal-free rodent protection. Sheath: halogen-free compound, UV-resistant Colour: black RAL 900 Field of application: Campus/backbone cabling, suitable for splicing, indoor installation in the case of increased mechanical requirements and danger through rodents, outdoor installation in dry tubes or directly in the ground, house lead-ins possible without additional transfer points (splices). FO universal cables Dimensions Outer ø Weight Tensile Transverse compression strength Fire load Article number strength permanent short-term mm kg/km N N/cm N/cm MJ/m kwh/m G 0/ OMe x LA70006 x LA70009 x LA70N08 0

106 06GigaLine GigaLine DQ 00 U GigaLine DQ 00 U GigaLine DQ 6 U Fibre optic universal cable, longitudinally watertight, with non-metallic rodent protection KL-U-DQ(ZNS)H n x m G/E Structure: Filled loose tube, central or stranded, water blocking tape, non-metallic rodent protection. Sheath: halogen-free compound, colour: yellow Field of application: Campus/backbone cabling, suitable for splicing, indoor installation in the case of increased mechanical requirements and danger through rodents, outdoor installation in dry tubes, house lead-ins possible without additional transfer points (splices). Dimen- Outer Weight Tensile Transverse Fire load Article number sions ø strength compression strength permanent short-term G 0/ G 0/ OM G 6./ E 9 0/ mm kg/km N N/cm N/cm MJ/m kwh/m (approx.) (approx.) (approx.) (max.) (max.) (approx.) (approx.) x UA000 8UA000 8UB7000 8UC7000 x UA000 8UA000 8UB7000 8UC7000 x UA000 8UA000 8UB7000 8UC7000 x UA000 8UA000 8UB7000 8UC7000 x UA000 8UA000 8UB7000 8UC7000 x UA0006 8UA0006 8UB UC70006 x UA0007 8UA0007 8UB UC70007 x UA0008 8UA0008 8UB UC70008 x UA0009 8UA0009 8UB UC70009 x UA0N0 8UA0N0 8UB70N0 8UC70N0 x UA0N0 8UA0N0 8UB70N0 8UC70N0 x UA0N0 8UA0N0 8UB70N0 8UC70N0 x UA0N0 8UA0N0 8UB70N0 8UC70N0 x UA0N0 8UA0N0 8UB70N0 8UC70N0 x UA0N06 8UA0N06 8UB70N06 8UC70N06 x UA0N07 8UA0N07 8UB70N07 8UC70N07 x UA0N08 8UA0N08 8UB70N08 8UC70N08 x UA0N09 8UA0N09 8UB70N09 8UC70N09 6 x UA0N0 8UA0N0 8UB70N0 8UC70N0 8 x UA0N 8UA0N 8UB70N 8UC70N 0 x UA0N 8UA0N 8UB70N 8UC70N x UA0N 8UA0N 8UB70N 8UC70N

107 GigaLine Fibre optic outdoor cables GigaLine DQ 00, 00, 6 N GigaLine DQ 00, 00, 6 SR Excellent performance, robust design but still easy to handle: these are the features of GigaLine outdoor cables. GigaLine outdoor cables were designed for use in city networks and industrial plants and in the campus and backbone area of LAN cabling and meet all demands made on transmission and installation conditions. Besides the designs with non-metallic rodent protection, the GigaLine product range also includes versions with a corrugated steel armour. FO outdoor cables If neither rodent protection nor mechanical protection are required, there are versions with a simple nonmetallic strain relief, alternatively with an easy-toassemble dry twisted structure or a classical petrolate filling, the latter optionally with a layered sheath as a perfect protection from humidity. A wide range of additional designs can also be manufactured, for example GigaLine outdoor cables with steel band or SWA armour or with an additional lead covering as a protection against chemicals. 07

108 08GigaLine GigaLine DQ 00 N GigaLine DQ 00 N GigaLine DQ 6 N Fibre optic outdoor cable, longitudinally watertight, with non-metallic rodent protection KL-A-DQ(ZNS)Y n x m G/E Structure: Filled loose tube, central or stranded, water blocking tape, non-metallic rodent protection. Sheath: PE, colour: black, UV-resistant Field of application: Outdoor cable for direct ground burial or in tubes, for MAN (city networks) and LAN (campus/backbone), suitable for splicing. Dimens- Outer Weight Tensile Transverse compression Fire load Article number ions ø strength strength permanent short-term G 0/ G 0/ OM G 6,/ E 9 0/ mm kg/km N N/cm N/cm MJ/m kwh/m (approx.) (approx.) (max.) (max.) (max.) (approx.) (approx.) x 7.9, AA000 8AA000 8AB7000 8AC7000 x 7.9, AA000 8AA000 8AB7000 8AC7000 x 6 7.9, AA000 8AA000 8AB7000 8AC7000 x 8 7.9, AA000 8AA000 8AB7000 8AC7000 x 0 7.9, AA000 8AA000 8AB7000 8AC7000 x 7.9, AA0006 8AA0006 8AB AC70006 x , AA0007 8AA0007 8AB AC70007 x , AA0008 8AA0008 8AB AC70008 x 8. 60, AA0009 8AA0009 8AB AC70009 x , AA0N0 8AA0N0 8AB70N0 8AC70N0 x , AA0N0 8AA0N0 8AB70N0 8AC70N0 x , AA0N0 8AA0N0 8AB70N0 8AC70N0 x , AA0N0 8AA0N0 8AB70N0 8AC70N0 x , AA0N0 8AA0N0 8AB70N0 8AC70N0 x. 0 6, AA0N06 8AA0N06 8AB70N06 8AC70N06 x. 0 6, AA0N07 8AA0N07 8AB70N07 8AC70N07 x. 0 6, AA0N08 8AA0N08 8AB70N08 8AC70N08 x. 0 6, AA0N09 8AA0N09 8AB70N09 8AC70N09 6 x. 78 6, AA0N0 8AA0N0 8AB70N0 8AC70N0 8 x. 78 6, AA0N 8AA0N 8AB70N 8AC70N 0 x 6.9 6, AA0N 8AA0N 8AB70N 8AC70N x , AA0N 8AA0N 8AB70N 8AC70N

109 GigaLine DQ 00 SR GigaLine DQ 00 SR GigaLine DQ 6 SR Fibre optic outdoor cable, longitudinally watertight, armoured with corrugated steel sheath KL-A-DQ(ZN)Y(SR)Y n x m G/E Structure: Filled loose tube, central or stranded, water blocking tape, strain relief Inner sheath: PE, armour: corrugated steel sheath Outer sheath: PE, colour: black, UV-resistant Field of application: Outdoor cable for installing direct ground burial or in tubes, for MAN (city networks) and LAN (campus/backbone), suitable for splicing. FO outdoor cables Dimens- Outer Weight Tensile Transverse compression Article number ions ø strength strength permanent short-term G 0/ G 0/ OM G 6,/ E 9 0/ mm kg/km N N/cm N/cm (approx.) (approx.) (max.) (max.) (max.) x,, AA00 8AA00 8AB700 8AC700 x,, AA00 8AA00 8AB700 8AC700 x 6,, AA00 8AA00 8AB700 8AC700 x 8,, AA00 8AA00 8AB700 8AC700 x 0,, AA00 8AA00 8AB700 8AC700 x,, AA006 8AA006 8AB7006 8AC7006 x 6,0 0, AA007 8AA007 8AB7007 8AC7007 x 0,0 0, AA008 8AA008 8AB7008 8AC7008 x,0 0, AA009 8AA009 8AB7009 8AC7009 x 8 8, 70, AA090 8AA090 8AB7090 8AC7090 x 0 8, 70, AA090 8AA090 8AB7090 8AC7090 x 0 8, 70, AA090 8AA090 8AB7090 8AC7090 x 0 8, 70, AA090 8AA090 8AB7090 8AC7090 x 0 8, 70, AA090 8AA090 8AB7090 8AC7090 x 8, 70, AA0906 8AA0906 8AB AC70906 x 8, 70, AA0907 8AA0907 8AB AC70907 x 8, 70, AA0908 8AA0908 8AB AC70908 x 8, 70, AA0909 8AA0909 8AB AC x,0 6, AA090 8AA090 8AB7090 8AC x,0 6, AA09 8AA09 8AB709 8AC709 0 x, 0, AA09 8AA09 8AB709 8AC709 x 7,0, AA09 8AA09 8AB709 8AC709 09

110 0GigaLine GigaLine abbreviations for easy identification of the structural elements to be found in fibre optic cables KL Fibre optical communication cable J Indoor cable AT Indoor cable, breakout V Semi-loose tube D Filled loose tube (ZN) Non-metallic strain relief elements H Halogen-free flame-retardant sheath of basic element (AT only) H Halogen-free flame-retardant sheath Number of fibres / number of loose tubes x number of Fibres per loose tube G Multimode fibre E Single-mode fibre Core diameter in µm (multimode fibre) Field diameter in µm (single-mode fibre) Cladding diameter in µm Attenuation coefficient in db/km Wavelength B = 80 nm F =,00/,0 nm H =,0 nm Bandwidth in MHz for km in the case of multimode fibres, dispersion parameter in ps/nm for km in the case of single-mode fibres Indoor fibre optical cable / 9 0

111 Universal fibre optic/outdoor cables / 9 0 Abbreviations Bandwidth in MHz for km in the case of multimode fibres, dispersion parameter in ps/nm for km in the case of single-mode fibres Wavelength B = 80 nm F =,00/,0 nm H =,0 nm Attenuation coefficient in db/km Cladding diameter in µm Core diameter in µm (multimode fibre) Field diameter in µm (single-mode fibre) G Multimode fibre E Single-mode fibre Number of fibres/number of loose tubes x number of Fibres per loose tube (SR)Y Corrugated steel sheath with outer sheath made of PE BY Armour with outer sheath made of PE Y Outer sheath made of PE (L)Y Layered sheath H Halogen-free flame-retardant outer sheath (ZN) Non-metallic strain relief elements (ZNS) Non-metallic strain relief elements and rodent protection elements F Filling compound in cable core Q Water blocking tape over cable core D Filled loose tube A Outdoor cable U Universal cable KL Fibre optical communication cable

112 GigaLine GigaLine Fibre qualities G0/ OMe G0/ OM G 0/ OMe G6./ OMe E9 0/ OSe Attenuation coefficient at 80 nm: max.. db/km max.. db/km max.. db/km max..0 db/km at,00 nm: max. 0.7 db/km max. 0.7 db/km max. 0.7 db/km max. 0.7 db/km at,0 nm: at,8 nm: at,0 nm: Bandwidth at 80 nm: min. 600 MHz x km min.,00 MHz x km min.,00 MHz x km min. 0 MHz x km at,00 nm: min.,00 MHz x km min. 00 MHz x km min. 00 MHz x km min. 800 MHz x km Laser bandwidth at 80 nm: min.,000 MHz x km min.,700 MHz x km Dispersion at,0 nm: at,0 nm: Segment length at Gigabit Ethernet at 80 nm (,000BASE-SX): min. 70 m min. 900 m min.,000 m min. 00 m at,00 nm (,000BASE-LX):,000 m min. min. 0 m min. 0 m min.,000 m Segment length at 0 Gigabit Ethernet at 80 nm (0GBASE-SR): min. 0 m min. 00 m min. 0 m min. 6 m max. 0.6 db/km max. 0.0 db/km max. 0. db/km max.. ps/nm x km max. 8 ps/nm x km at,00 nm (0GBASE-LX): min. 900 m min. 00 m min. 00 m min. 0 m min. 0,000 Numerical aperture Nominal value 0.0 Nominal value 0.0 Nominal value 0.0 Nominal value 0.7 Nominal value 0. Refraction index at 80 nm: Nominal value.8 Nominal value.8 Nominal value.8 Nominal value.96 at,00 nm: Nominal value.77 Nominal value.77 Nominal value.8 Nominal value.9 at,0 nm: Nominal value.67 at,0 nm: Nominal value.68 Other Fibre qualities on request Test load 00 kpsi 00 kpsi 00 kpsi 00 kpsi 00 kpsi

113 GigaLine colour codes Wires (in the case of stranded loose tubes) Fibres (in the case of loose tubes) Counting wire red Fibre no. Colour red green Other wires green for G0/ blue blue for G6./ yellow yellow for E9 0/ white 6 grey Dummy natural colour 7 brown elements 8 violet 9 turquoise 0 black orange pink red-black green-black blue-black 6 yellow-black 7 withe-black 8 grey-black 9 brown-black The wires are counted consecutively starting with the wire adjacent to the counting element. Dummy elements are not included in counting. 0 violet-black turquoise-black natural-black orange-black pink-black Fibre qualities & colour codes

114 Fibre Optic Solutions Fibre optical solutions cables and systems for LAN, MAN, WAN and SAN As the degree of automation increases in industry and the information density rises in office communication, higher and higher demands are made on the transmission of analog and digital data. In this situation, conventional links based on copper cable engineering often reach the limits of their performance. FLine the system for glass fibres The constant increase in Internet and Intranet traffic, multimedia applications and the implementation of socalled SANs or Storage Area Networks in companies has led to fundamental changes in the traffic and load distribution in the networks. Also, new media require new passive network infrastructures. On the basis of EN 07, KERPEN has introduced the new FLine classes FLine 0, FLine 00 and FLine 0 for link lengths for 0 GbE and GbE. FLine systems engineering is based on pre-terminated ready-to-connect units. The ready-made cables guarantee rapid, reliable and economic installation. The quality of the link is ensured by matching system components. The installation times are short and easy to calculate. GigaLine enhanced fibre optic technology In conjunction with multimode fibres and single-mode fibres, GigaLine fibre optical cables offer reserves which go far beyond the specifications of the standard. Following the fibre categories OM, OM, OM and OS according to EN 07, KERPEN offers the quality grades OMe, OMe, OMe and OSe with optimised transmission characteristics.

115 FLine the complete system for fibre-to-the-desk and fibre-to-the-office at maximum quality and security Building distributor Multifunctional office and floor distributor for ready-made cables and/or splicing Collapsed backbone network topology System overview 9" patch panel for ready-made cables and/or splicing with coloured pigtails FLine FLine smart FLine compact Ready-made components, high-fibre count ready-made universal cables for the secondary and backbone area Ready-made mini-breakout and breakout cables for floor cabling Conventional network topology Building distributor Floor distributor 9" patch panel for ready-made cables and/or splicing with coloured pigtails FLine FLine smart FLine compact Ready-made components, high-fibre count preassembled universal cables for the secondary and backbone area Ready-made mini-breakout and breakout cables for floor cabling

116 6FLine FLine 0, FLine 00 und FLine 0 the new FLine classes In order to give the user a clear protocol-dependent planning foundation building up-on EN 07 for link lengths at 0 GbE and GbE, KERPEN has introduced the new FLine classes: FLine 0 FLine 00 FLine 0 0, 00 and 0 refer to the maximum link lengths for 0 GbE. These FLine classes include components optimised for performance and quality which together provide an ideally matched system. The interaction of high-quality fibres (OMe, OM, OMe) which go far beyond the standard and of high-quality plug connectors allow maximum range and performance for the applications involved (GbE / 0 GbE). The system components are selected in such a way that the demands made on the link length (0, 00 and 0) and on the data rate are met. This is why KERPEN consistently uses the same fibre quality for each system (cables, pigtails, patch cords). For the user, this means that he selects the FLine class (system) he requires depending on the link length he needs and the protocols to be transmitted (GbE / 0 GbE). Tables and give him the protocol-dependent attenuation budget according to EN 07. From this he can derive the number of possible connections for the entire link. When the FLine classes were put together, the following matched system components were taken into account: Fibre optical cables (GigaLine ) with laser-/dispersionoptimised multimode fibres which go far beyond the requirements of the standard (OMe, OM or OMe) and have the necessary reserve performance. (For fibre specifications please see GigaLine ) Fibre optical connectors (LC or SC etc.) with low insertion losses and high return losses attenuation. Maximum link lengths for 0 Gigabit Ethernet system solutions Multimode G 0 Multimode G 0 FLine classes for 0 GbE FLine classes for 0 GbE FLine 0 FLine 00 FLine 0 Maximum link length for GbE ,000 Attenuation budget,6 db,6 db,6 db for the link and for GbE application Recommended ST, SC, LC SC, LC SC,LC plug connectors FC-PC E,000 Number of possible 6 plug connections All data refer to the first optical window, 80 nm FLine 0 FLine 00 FLine 0 Maximum link length for GbE 0GBASE-SR Attenuation budget,8 db,6 db,6 db for the link and for 0 GbE application Recommended ST, SC, LC SC, LC SC,LC plug connectors FC-PC E,000 Number of possible 8 6 plug connections All data refer to the first optical window, 80 nm Maximum link lengths for Gigabit Ethernet system solutions

117 Diagram shows the system reserves resulting from the high-quality fibres and connectors in relation to the EN 07 standard. The main advantages of these system reserves are as follows: Longer transmission distances for certain applications (00 Mb/s, GbE/s, 0 GbE/s) The option of inserting more patch cords or splices Additional losses resulting from aging processes can be compensated for Network extensions can be implemented more easily and with a certain degree of security within the link length Diagram : FLine 0, 00 and 0 system reserves in relation to the standard Attenuation limiting FLine 0 FLine 00 FLine 0 Norm OM Norm OM Dispersion limiting Quality is our benchmark In the manufacturing of fibre optical connectors, sophisticated grinding and polishing processes are necessary in addition to the adjustment of the fibres in the ferrule. The aim here is to use precisely optimised processes to fashion the connector in such a way that insertion losses and reflections are kept to a minimum. For this purpose, the so-called PC (physical contact) finish was developed, mainly for multimode fibres but also for single-mode ones. The spherical polish of the ferrule, which is flexibly supported in the plug housing, results in a fibre/fibre transition on the end faces. Thus, when two connectors are inserted into a coupling, the spring pressure causes all of the air between the two fibres of both plugs to be pushed out. The glass/glass transition then has virtually no reflections and low losses. In order to maximise the performance of a PC plug, the surface parameters of the plugs must be carefully monitored during the polishing process. The interferometer is a leading edge measuring instrument for this purpose. The overlapping of coherent light waves is used as a basis for measuring the quality of optical surfaces (ferrule surfaces). System overview The most important parameters are as follows: Bandwidth in MHz The pole offset: this is the distance between the highest point of the ferrule and the centre of the fibre (eccentricity of the polish) The tolerances of the ferrule opening to the diameter of the fibre The optimum radius of the ferrule and the fibre. The fibre height in the ferrule (undercut, protrusion) 7

118 8FLine These parameters are important factors determining the long-term behaviour of a connector after plastic deformation. The following are derived in this way: Physical contact Insertion losses / return losses Fibre stress Fibre migration All FLine components are subjected to the most stringent of pre-delivery inspections. These include the following: The attenuation measurement of each individual ready-made component. The defined limits for attenuation measurement go far beyond the requirements of the international standards Optional OTDR measurement, for example for readymade components The monitoring of the individual process flows for plug manufacture via interferometer Application: 0 GbE; attenuation budget OM =.8 db, OM =.6 db Number of plug connectors Insertion attenuation of plug connector in db Link length in meters FLine 0 0 / / / / / < 0. FLine / < 0. FLine / < 0. All data refer to the first optical window (80 nm) Application: GbE; attenuation budget.6 db Number of plug connectors Insertion attenuation of plug connector in db Link length in meters FLine / / / / < 0. FLine < 0. FLine < 0. All data refer to the first optical window (80 nm)

119 GigaLine ready-made safely through thick and thin Ready-to-connect units are at the heart of FLine systems engineering. Ready-made GigaLine cables guarantee rapid, reliable and economic installation. The quality of the link is ensured by matched system components. The installation times can now be calculated. A permanent solution On site installation often takes place in unfavourable conditions. Humidity, dirt and inaccessible places are common. In order to do justice to the conditions involved, KERPEN has developed Distribution heads and installation tubes of different protection classes for fibre optical cables with filled loose tubes. IP0 (dust-proof) for indoor cabling IP67 (splash-proof) for rough construction site environments and for outdoor cabling GigaLine ready-made Ready-made GigaLine ensures that these conditions do not affect the quality of the links, either during installation or afterwards. The installation tube is flexible and has a small diameter. This means that the ready-made trunk can be easily fed into narrow, intricate shafts for secondary cabling and installation ducts. There is a power grip connection to the distribution head. Like all other strain relief elements, it works on the cladding, not the cores. This means that the fibres remain stress-free. The design of the distribution head ensures the stability of the physical parameters and a long life. Time is money GigaLine VKT stands for reliable and predictable installations. Reduced install time. Subsequent down times, for example due to the interruption of current operation of a computer system, are minimised. This makes it possible to dispense with the splicing of cables or mounting of plugs, which often take place under adverse conditions on location. High investments in splicing devices and specially trained expert personnel can also be dispensed with. GigaLine VKT can also be used as cables with one end ready-made. Fields of application GigaLine ready-made is the ideal choice for backbone cabling in the primary and secondary area and for collapsed backbones. Quality means maximum safety The assembly of plugs with high-quality ceramic ferrules is carried out in a clean environment. The end faces of the plugs are polished in an optimum way, this ensuring excellent plug transitions in reproducible quality (insertion and return losses). A test report showing the attenuation values for each fibre is supplied with the unit. As an option, OTDR measurements can also be carried out. 9

120 0FLine VKT IP67 GigaLine DQ 00, 00, 6 N Ready-made outdoor fibre optical cable, longitudinally watertight, with non-metallic rodent protection Type: KL-A-DQ(ZNS)Y Aluminium distribution head with installation tube Protection from water and dirt Strain relief via distribution head Stress-free fibres Stability of transmission parameters Long life Characteristics of plug: Single-mode standard Multimode standard, FLine 0 Multimode FLine 00, FLine 0 Characteristics of fibre: E9...0/ Insertion losses: < 0. db; return losses: > 0 db Insertion losses: < 0. db; return losses: > db Insertion losses: < 0. db; return losses: > db Single-mode fibre, transmission characteristics better than OS. Attenuation coefficient: 0.6 db/km at,0 nm; 0. db/km at,0 nm Dispersion: max.. ps/nm x km at,0 nm; max. 8ps/nm x km at,0 nm G0/ Multimode fibre optimised for Gigabit Ethernet, transmission characteristics better than OM, OM. FLine 0 Attenuation coefficient:. db/km at 80 nm; 0.7 db/km at,00 nm Bandwidth: min. 600 MHz x km at 80 nm; min.,00 MHz x km at,00 nm Segment length with Gigabit Ethernet: min. 70 m at 80 nm; min.,000 m at,00 nm Segment length with 0 Gigabit Ethernet: min. 0 m at 80 nm; min. 900 m at,00 nm G0/ OM Multimode fibre optimised for 0 Gigabit Ethernet, transmission characteristics better than OM. FLine 00 Attenuation coefficient:. db/km at 80 nm; 0.7 db/km at,00 nm Laser bandwidth: min.,000 MHz x km at 80 nm Bandwidth: min.,00 MHz x km at 80 nm; min. 00 MHz x km at,00 nm Segment length with Gigabit Ethernet: min. 900 m at 80 nm; min. 0 m at,00 nm Segment length with 0 Gigabit Ethernet: min. 00 m at 80 nm; min. 00 m at,00 nm G0/ OM e Multimode fibre optimised for 0 Gigabit Ethernet, transmission characteristics better than OM. FLine 0 G6,/ Characteristics of the distribution head: Number Ø of distribution head Ø of installation Strain relief of Fibres in mm (max) tube in mm (max) N (max) to to Attenuation coefficient:. db/km at 80 nm; 0.7 db/km at,00 nm Laser bandwidth: min.,700 MHz x km at 80 nm Bandwidth: min.,00 MHz x km at 80 nm; min. 00 MHz x km at,00 nm Segment length with Gigabit Ethernet: min.,000 m at 80 nm; min. 0 m at,00 nm Segment length with 0 Gigabit Ethernet: min. 0 m at 80 nm; min. 00 m at,00 nm Multimode fibre optimised for 0 Gigabit Ethernet, transmission characteristics better than OM. Attenuation coefficient:.0 db/km at 80 nm; 0.7 db/km at,00 nm Bandwidth: min. 0 MHz x km at 80 nm; min. 800 MHz x km at,00 nm Segment length with Gigabit Ethernet: min. 00 m at 80 nm; min.,000 m at,00 nm Segment length with 0 Gigabit Ethernet: min. 6 m at 80 nm; min. 0 m at,00 nm

121 Single-mode standard: insertion losses < 0. db; return losses: > 0 db No. of Fibres SC ST E,000 E,000HRL FC-PC FC-PC HRL 9VA00XXX 9VA09XXX 9VA0IXXX 9VA0SXXX 9VAXXX 9VACXXX 6 9VA0XXX 9VA0AXXX 9VA0JXXX 9VA0TXXX 9VAXXX 9VADXXX 8 9VA0XXX 9VA0BXXX 9VA0KXXX 9VA0UXXX 9VAXXX 9VAEXXX 9VA0XXX 9VA0CXXX 9VA0LXXX 9VA0VXXX 9VA6XXX 9VAFXXX 6 9VA0XXX 9VA0DXXX 9VA0MXXX 9VA0WXXX 9VA7XXX 9VAGXXX 9VA06XXX 9VA0FXXX 9VA0PXXX 9VA0YXXX 9VA9XXX 9VAIXXX 8 9VA08XXX 9VA0HXXX 9VA0RXXX 9VA0XXX 9VABXXX 9VAKXXX FLine 0, Multimode G0/ OM: insertion losses: < 0. db; return losses: > db No. of Fibres SC ST E,000 MT-RJ FC-PC LC 9VAXXX 9VAAXXX 9VAJXXX 9VAKXXX 9VALXXX 9VAWXXX 6 9VAXXX 9VABXXX 9VAKXXX 9VALXXX 9VAMXXX 9VAXXXX 8 9VAXXX 9VACXXX 9VALXXX 9VAMXXX 9VANXXX 9VAYXXX 9VAXXX 9VADXXX 9VAMXXX 9VANXXX 9VAPXXX 9VAZXXX 6 9VAXXX 9VAEXXX 9VANXXX 9VAPXXX 9VAQXXX 9VA0XXX 9VA7XXX 9VAGXXX 9VAQXXX 9VARXXX 9VASXXX 9VAXXX 8 9VA9XXX 9VAIXXX 9VASXXX 9VATXXX 9VAUXXX 9VAXXX GigaLine ready-made FLine 00, Multimode G0/ OM: insertion losses: < 0. db; return losses: > db No. of Fibres SC ST E,000 MT-RJ FC-PC LC 9VAXXXX 9VAXXX 6 9VAYXXX 9VA6XXX 8 9VAZXXX 9VA7XXX 9VA60XXX 9VA8XXX 6 9VA6XXX 9VA9XXX 9VA6XXX 9VABXXX 8 9VA6XXX - 9VADXXX FLine 0, Multimode G0/ OM e : insertion losses: < 0. db; return losses: > db No. of Fibres SC ST E,000 MT-RJ FC-PC LC 9VAXXXXXX 9VAEXXX 6 9VAXXXXXX 9VAFXXX 8 9VAXXXXXX 9VAGXXX 9VAXXXXXX 9VAHXXX 6 9VAXXXXXX 9VAIXXX 9VAXXXXXX 9VAKXXX 8 9VAXXXXXX 9VAMXXX Multimode G6./ OM, standard: insertion losses: < 0. db; return losses: > db No. of Fibres SC ST E,000 MT-RJ FC-PC LC 9VATXXX 9VAXXX 9VABXXX 9VAUXXX 9VAVXXX 6 9VAUXXX 9VAXXX 9VACXXX 9VAVXXX 9VAWXXX 8 9VAVXXX 9VAXXX 9VADXXX 9VAWXXX 9VAXXXX 9VAWXXX 9VAXXX 9VAEXXX 9VAXXXX 9VAYXXX 6 9VAXXXX 9VA6XXX 9VAFXXX 9VAYXXX 9VAZXXX 9VAZXXX 9VA8XXX 9VAHXXX 9VA0XXX 9VAXXX 8 9VAXXX 9VAAXXX 9VAJXXX 9VAXXX 9VAXXX xxx length in m; other designs with other connectors on request

122 FLine VKT IP0 GigaLine DQ 00, 00, 6 U Ready-made universal fibre optical cable, longitudinally watertight, with non-metallic rodent protection Type: KL-U-DQ(ZNS)H Aluminium distribution head with installation tube Protection from dirt Strain relief via distribution head Stress-free fibres Stability of transmission parameters Long life Characteristics of plug: Single-mode standard Multimode standard, FLine 0 Multimode FLine 00, FLine 0 Fibre characteristics: E9...0/ Insertion losses: < 0. db; return losses: > 0 db Insertion losses: < 0. db; return losses: > db Insertion losses: < 0. db; return losses: > db Single-mode fibre, transmission characteristics better than OS. Attenuation coefficient: 0.6 db/km at,0 nm; 0. db/km at,0 nm Dispersion: max.. ps/nm x km at,0 nm; max. 8 ps/nm x km at,0 nm G0/ Multimode fibre optimised for Gigabit Ethernet, transmission characteristics better than OM, OM. FLine 0 Attenuation coefficient:. db/km at 80 nm; 0.7 db/km at,00 nm Bandwidth: min. 600 MHz x km at 80 nm; min.,00 MHz x km at,00 nm Segment length with Gigabit Ethernet: min. 70 m at 80 nm; min.,000 m at,00 nm Segment length with 0 Gigabit Ethernet: min. 0 m at 80 nm; min. 900 m at,00 nm G0/ OM Multimode fibre optimised for 0 Gigabit Ethernet, transmission characteristics better than OM. FLine 00 Attenuation coefficient:. db/km at 80 nm; 0.7 db/km at,00 nm Laser bandwidth: min.,000 MHz x km at 80 nm Bandwidth: min.,00 MHz x km at 80 nm; min. 00 MHz x km at,00 nm Segment length with Gigabit Ethernet: min. 900 m at 80 nm; min. 0 m at,00 nm Segment length with 0 Gigabit Ethernet: min. 00 m at 80 nm; min. 00 m at,00 nm G0/ OM e Multimode fibre optimised for 0 Gigabit Ethernet, transmission characteristics better than OM. FLine 0 G6,/ Characteristics of the distribution head: Number Ø of distribution head Ø of installation Strain relief of Fibres in mm (max) tube in mm (max) N (max) to to Attenuation coefficient:. db/km at 80 nm; 0.7 db/km at,00 nm Laser bandwidth: min.,700 MHz x km at 80 nm Bandwidth: min.,00 MHz x km at 80 nm; min. 00 MHz x km at,00 nm Segment length with Gigabit Ethernet: min.,000 m at 80 nm; min. 0 m at,00 nm Segment length with 0 Gigabit Ethernet: min. 0 m at 80 nm; min. 00 m at,00 nm Multimode fibre optimised for 0 Gigabit Ethernet, transmission characteristics better than OM. Attenuation coefficient:.0 db/km at 80 nm; 0.7 db/km at,00 nm Bandwidth: min. 0 MHz x km at 80 nm; min. 800 MHz x km at,00 nm Segment length with Gigabit Ethernet: min. 00 m at 80 nm; min.,000 m at,00 nm Segment length with 0 Gigabit Ethernet: min. 6 m at 80 nm; min. 0 m at,00 nm

123 GigaLine VKT IP0, equipped with plugs at both ends and installation tube Single-mode standard: insertion losses < 0. db; return losses: > 0 db No. of Fibres SC ST E,000 E,000HRL FC-PC FC-PC HRL 9VUI0XXX 9VUI9XXX 9VUIIXXX 9VUISXXX 9VULXXX 9VULCXXX 6 9VUIXXX 9VUIAXXX 9VUIJXXX 9VUITXXX 9VULXXX 9VULDXXX 8 9VUIXXX 9VUIBXXX 9VUIKXXX 9VUIUXXX 9VULXXX 9VULEXXX 9VUIXXX 9VUICXXX 9VUILXXX 9VUIVXXX 9VUL6XXX 9VULFXXX 6 9VUIXXX 9VUIDXXX 9VUIMXXX 9VUIWXXX 9VUL7XXX 9VULGXXX 9VUI6XXX 9VUIFXXX 9VUIPXXX 9VUIYXXX 9VUL9XXX 9VULIXXX 8 9VUI8XXX 9VUIHXXX 9VUIRXXX 9VUJ0XXX 9VULBXXX 9VULKXXX FLine 0, Multimode G0/ OM: insertion losses: < 0. db; return losses: > db No. of Fibres SC ST E,000 MT-RJ FC-PC LC 9VUJXXX 9VUJAXXX 9VUJJXXX 9VUKKXXX 9VULLXXX 9VUMWXXX 6 9VUJXXX 9VUJBXXX 9VUJKXXX 9VUKLXXX 9VULMXXX 9VUMXXXX 8 9VUJXXX 9VUJCXXX 9VUJLXXX 9VUKMXXX 9VULNXXX 9VUMYXXX 9VUJXXX 9VUJDXXX 9VUJMXXX 9VUKNXXX 9VULPXXX 9VUMZXXX 6 9VUJXXX 9VUJEXXX 9VUJNXXX 9VUKPXXX 9VULQXXX 9VUN0XXX 9VUJ7XXX 9VUJGXXX 9VUJQXXX 9VUKRXXX 9VULSXXX 9VUNXXX 8 9VUJ9XXX 9VUJIXXX 9VUJSXXX 9VUKTXXX 9VULUXXX 9VUNXXX GigaLine ready-made FLine 00, Multimode G0/ OM: insertion losses: < 0. db; return losses: > db No. of Fibres SC ST E,000 MT-RJ FC-PC LC 9VUNXXXX 9VUNXXX 6 9VUNYXXX 9VUN6XXX 8 9VUNZXXX 9VUN7XXX 9VUP0XXX 9VUN8XXX 6 9VUPXXX 9VUN9XXX 9VUPXXX 9VUNBXXX 8 9VUPXXX 9VUNDXXX FLine 0, Multimode G0/ OM e : insertion losses: < 0. db; return losses: > db No. of Fibres SC ST E,000 MT-RJ FC-PC LC 9VAXXXXXX 9VUNEXXX 6 9VAXXXXXX 9VUNFXXX 8 9VAXXXXXX 9VUNGXXX 9VAXXXXXX 9VUNHXXX 6 9VAXXXXXX 9VUNIXXX 9VAXXXXXX 9VUNKXXX 8 9VAXXXXXX 9VUNMXXX Multimode G6./ OM, standard: insertion losses: < 0. db; return losses > db No. of Fibres SC ST E,000 MT-RJ FC-PC LC 9VUJTXXX 9VUKXXX 9VUKBXXX 9VUKUXXX 9VULVXXX 6 9VUJUXXX 9VUKXXX 9VUKCXXX 9VUKVXXX 9VULWXXX 8 9VUJVXXX 9VUKXXX 9VUKDXXX 9VUKWXXX 9VULXXXX 9VUJWXXX 9VUKXXX 9VUKEXXX 9VUKXXXX 9VULYXXX 6 9VUJXXXX 9VUK6XXX 9VUKFXXX 9VUKYXXX 9VULZXXX 9VUJZXXX 9VUK8XXX 9VUKHXXX 9VUL0XXX 9VUMXXX 8 9VUKXXX 9VUKAXXX 9VUKJXXX 9VULXXX 9VUMXXX xxx length in m; other designs with other connectors on request

124 FLine GigaLine VKT mini-breakout IP0 GigaLine M 00, 00, 6 Ready-made fibre optical mini-breakout cable. Type: KL-J-V(ZN)H Splice-free distribution with installation tube Protection from dirt Stability of transmission parameters Long life Field of application: Floor cabling Characteristics of plug: Single-mode standard Multimode standard, FLine 0 Multimode FLine 00, FLine 0 Fibre characteristics: E9...0/ Insertion losses: < 0. db; return losses: > 0 db Insertion losses: < 0. db; return losses: > db Insertion losses: < 0. db; return losses: > db Characteristics of installation tube: No. of Fibres Ø of installation tube Strain relief in in mm (max) N (max) to 7 0 Single-mode fibre, transmission characteristics better than OS. Attenuation coefficient: 0.6 db/km at,0 nm; 0. db/km at,0 nm Dispersion: max.. ps/nm x km at,0 nm; max. 8 ps/nm x km at,0 nm G0/ Multimode fibre optimised for Gigabit Ethernet, transmission characteristics better than OM, OM. FLine 0 Attenuation coefficient:. db/km at 80 nm; 0.7 db/km at,00 nm Bandwidth: min. 600 MHz x km at 80 nm; min.,00 MHz x km at,00 nm Segment length with Gigabit Ethernet: min. 70 m at 80 nm; min.,000 m at,00 nm Segment length with 0 Gigabit Ethernet: min. 0 m at 80 nm; min. 900 m at,00 nm G0/ OM Multimode fibre optimised for 0 Gigabit Ethernet, transmission characteristics better than OM. FLine 00 Attenuation coefficient:. db/km at 80 nm; 0.7 db/km at,00 nm Laser bandwidth: min.,000 MHz x km at 80 nm Bandwidth: min.,00 MHz x km at 80 nm; min. 00 MHz x km at,00 nm Segment length with Gigabit Ethernet: min. 900 m at 80 nm; min. 0 m at,00 nm Segment length with 0 Gigabit Ethernet: min. 00 m at 80 nm; min. 00 m at,00 nm G0/ OM e Multimode fibre optimised for 0 Gigabit Ethernet, transmission characteristics better than OM. FLine 0 G6,/ Attenuation coefficient:. db/km at 80 nm; 0.7 db/km at,00 nm Laser bandwidth: min.,700 MHz x km at 80 nm Bandwidth: min.,00 MHz x km at 80 nm; min. 00 MHz x km at,00 nm Segment length with Gigabit Ethernet: min.,000 m at 80 nm; min. 0 m at,00 nm Segment length with 0 Gigabit Ethernet: min. 0 m at 80 nm; min. 00 m at,00 nm Multimode fibre optimised for 0 Gigabit Ethernet, transmission characteristics better than OM. Attenuation coefficient:.0 db/km at 80 nm; 0.7 db/km at,00 nm Bandwidth: min. 0 MHz x km at 80 nm; min. 800 MHz x km at,00 nm Segment length with Gigabit Ethernet: min. 00 m at 80 nm; min.,000 m at,00 nm Segment length with 0 Gigabit Ethernet: min. 6 m at 80 nm; min. 0 m at,00 nm

125 GigaLine VKT (ready-made) mini-breakout IP0, equipped with plugs at both ends and installation tube Single-mode standard: insertion losses < 0. db; return losses: > 0 db No. of Fibres SC ST E,000 E,000HRL FC-PC FC-PC HRL 9VM00XXX 9VM06XXX 9VM0PXXX 9VM0VXXX 9VM0CXXX 9VM0IXXX 9VM0XXX 9VM07XXX 9VM0QXXX 9VM0WXXX 9VM0DXXX 9VM0JXXX 6 9VM0XXX 9VM08XXX 9VM0RXXX 9VM0XXXX 9VM0EXXX 9VM0KXXX 8 9VM0XXX 9VM09XXX 9VM0SXXX 9VM0YXXX 9VM0FXXX 9VM0LXXX 0 9VM0XXX 9VM0AXXX 9VM0TXXX 9VM0ZXXX 9VM0GXXX 9VM0MXXX 9VM0XXX 9VM0BXXX 9VM0UXXX 9VM0XXX 9VM0HXXX 9VM0NXXX FLine 0, Multimode G0/ OM: insertion losses: < 0. db; return losses: > db No. of Fibres SC ST E,000 MT-RJ FC-PC LC 9VMXXX 9VM7XXX 9VMDXXX 9VMQXXX 9VMJXXX 9VUMWXXX 6 9VMXXX 9VM8XXX 9VMEXXX 9VMRXXX 9VMKXXX 9VUMXXXX 8 9VMXXX 9VM9XXX 9VMFXXX 9VMSXXX 9VMLXXX 9VUMYXXX 9VMXXX 9VMAXXX 9VMGXXX 9VMTXXX 9VMMXXX 9VUMZXXX 6 9VMXXX 9VMBXXX 9VMHXXX 9VMUXXX 9VMNXXX 9VUN0XXX 9VM6XXX 9VMCXXX 9VMIXXX 9VMVXXX 9VMPXXX 9VUNXXX GigaLine ready-made FLine 00, Multimode G0/ OM: insertion losses: < 0. db; return losses: > db No. of Fibres SC ST E,000 MT-RJ FC-PC LC 9VMLXXX 9VMSXXX 6 9VMMXXX 9VMTXXX 8 9VMNXXX 9VMUXXX 9VMPXXX 9VMVXXX 6 9VMQXXX 9VMWXXX 9VMRXXX 9VMXXXX FLine 0, Multimode G0/ OM e : insertion losses: < 0. db; return losses: > db No. of Fibres SC ST E,000 MT-RJ FC-PC LC 9VMYXXX 9VMXXX 6 9VMZXXX 9VMXXX 8 9VM0XXX 9VM6XXX 9VMXXX 9VM7XXX 6 9VMXXX 9VM8XXX 9VMXXX 9VM9XXX Multimode G6./ OM, standard: insertion losses: < 0. db; return losses > db No. of Fibres SC ST E,000 MT-RJ FC-PC LC 9VMWXXX 9VMXXX 9VMEXXX 9VMKXXX 9VM8XXX 6 9VMXXXX 9VMXXX 9VMFXXX 9VMLXXX 9VM9XXX 8 9VMYXXX 9VMXXX 9VMGXXX 9VMMXXX 9VMAXXX 9VMZXXX 9VMXXX 9VMHXXX 9VMNXXX 9VMBXXX 6 9VM0XXX 9VM6XXX 9VMIXXX 9VMPXXX 9VMCXXX 9VMXXX 9VM7XXX 9VMJXXX 9VMQXXX 9VMDXXX xxx length in m; other designs with other connectors on request

126 6FLine GigaLine VKT Breakout IP0 GigaLine AT 00, 00, 6 Ready-made fibre optical breakout cable Type: KL-J-V(ZN)H Splice-free distribution with installation tube Protection from dirt. Stability of transmission parameters. Long life. Field of application: Floor cabling Characteristics of plug: Single-mode standard Multimode standard, FLine 0 Multimode FLine 00, FLine 0 Fibre characteristics: E9...0/ Insertion losses: < 0. db; return losses: > 0 db Insertion losses: < 0. db; return losses: > db Insertion losses: < 0. db; return losses: > db Characteristics of installation tube: No. of Fibres Ø of installation tube Strain relief in in mm (max) N (max) to 7 0 Single-mode fibre, transmission characteristics better than OS. Attenuation coefficient: 0.6 db/km at,0 nm; 0. db/km at,0 nm Dispersion: max.. ps/nm x km at,0 nm; max. 8 ps/nm x km at,0 nm G0/ Multimode fibre optimised for Gigabit Ethernet, transmission characteristics better than OM, OM. FLine 0 Attenuation coefficient:. db/km at 80 nm; 0.7 db/km at,00 nm Bandwidth: min. 600 MHz x km at 80 nm; min.,00 MHz x km at,00 nm Segment length with Gigabit Ethernet: min. 70 m at 80 nm; min.,000 m at,00 nm Segment length with 0 Gigabit Ethernet: min. 0 m at 80 nm; min. 900 m at,00 nm G0/ OM Multimode fibre optimised for 0 Gigabit Ethernet, transmission characteristics better than OM FLine 00 Attenuation coefficient:. db/km at 80 nm; 0.7 db/km at,00 nm Laser bandwidth: min.,000 MHz x km at 80 nm Segment length with Gigabit Ethernet: min. 900 m at 80 nm; min. 0 m at,00 nm Segment length with 0 Gigabit Ethernet: min. 00 m at 80 nm; min. 00 m at,00 nm G0/ OM e Multimode fibre optimised for 0 Gigabit Ethernet, transmission characteristics better than OM. FLine 0 G6,/ Attenuation coefficient:. db/km at 80 nm; 0.7 db/km at,00 nm Laser bandwidth: min.,700 MHz x km at 80 nm Bandwidth: min.,00 MHz x km at 80 nm; min. 00 MHz x km at,00 nm Segment length with Gigabit Ethernet: min.,000 m at 80 nm; min. 0 m at,00 nm Segment length with 0 Gigabit Ethernet: min. 0 m at 80 nm; min. 00 m at,00 nm Multimode fibre optimised for 0 Gigabit Ethernet, transmission characteristics better than OM. Attenuation coefficient:.0 db/km at 80 nm; 0.7 db/km at,00 nm Bandwidth: min. 0 MHz x km at 80 nm; min. 800 MHz x km at,00 nm Segment length with Gigabit Ethernet: min. 00 m at 80 nm; min.,000 m at,00 nm Segment length with 0 Gigabit Ethernet: min. 6 m at 80 nm; min. 0 m at,00 nm

127 GigaLine VKT breakout IP0, equipped with plugs at both ends and installation tube Single-mode standard: insertion losses < 0. db; return losses: > 0 db No. of Fibres SC ST E,000 E,000HRL FC-PC FC-PC HRL 9VB00XXX 9VB06XXX 9VB0PXXX 9VB0VXXX 9VB0CXXX 9VB0IXXX 9VB0XXX 9VB07XXX 9VB0QXXX 9VB0WXXX 9VB0DXXX 9VB0JXXX 6 9VB0XXX 9VB08XXX 9VB0RXXX 9VB0XXXX 9VB0EXXX 9VB0KXXX 8 9VB0XXX 9VB09XXX 9VB0SXXX 9VB0YXXX 9VB0FXXX 9VB0LXXX 0 9VB0XXX 9VB0AXXX 9VB0TXXX 9VB0ZXXX 9VB0GXXX 9VB0MXXX 9VB0XXX 9VB0BXXX 9VB0UXXX 9VB0XXX 9VB0HXXX 9VB0NXXX FLine 0, Multimode G0/ OM: insertion losses: < 0. db; return losses: > db No. of Fibres SC ST E,000 MT-RJ FC-PC LC 9VBXXX 9VB7XXX 9VBDXXX 9VBQXXX 9VBJXXX 9VUBWXXX 6 9VBXXX 9VB8XXX 9VBEXXX 9VBRXXX 9VBKXXX 9VUBXXXX 8 9VBXXX 9VB9XXX 9VBFXXX 9VBSXXX 9VBLXXX 9VUBYXXX 9VBXXX 9VBAXXX 9VBGXXX 9VBTXXX 9VBMXXX 9VUBZXXX 6 9VBXXX 9VBBXXX 9VBHXXX 9VBUXXX 9VBNXXX 9VUB0XXX 9VB6XXX 9VBCXXX 9VBIXXX 9VBVXXX 9VBPXXX 9VUBXXX GigaLine ready-made FLine 00, Multimode G0/ OM: insertion losses: < 0. db; return losses: > db No. of Fibres SC ST E,000 MT-RJ FC-PC LC 9VBLXXX 9VBSXXX 6 9VBMXXX 9VBTXXX 8 9VBNXXX 9VBUXXX 9VBPXXX 9VBVXXX 6 9VBQXXX 9VBWXXX 9VBRXXX 9VBXXXX FLine 0, Multimode G0/ OM e : insertion losses: < 0. db; return losses: > db No. of Fibres SC ST E,000 MT-RJ FC-PC LC 9VBYXXX 9VBXXX 6 9VBZXXX 9VBXXX 8 9VB0XXX 9VB6XXX 9VBXXX 9VB7XXX 6 9VBXXX 9VB8XXX 9VBXXX 9VB9XXX Multimode G6./ OM, standard: insertion losses: < 0. db; return losses: > db No. of Fibres SC ST E,000 MT-RJ FC-PC LC 9VMWXXX 9VMXXX 9VMEXXX 9VMKXXX 9VM8XXX 6 9VMXXXX 9VMXXX 9VMFXXX 9VMLXXX 9VM9XXX 8 9VMYXXX 9VMXXX 9VMGXXX 9VMMXXX 9VMAXXX 9VMZXXX 9VMXXX 9VMHXXX 9VMNXXX 9VMBXXX 6 9VM0XXX 9VM6XXX 9VMIXXX 9VMPXXX 9VMCXXX 9VMXXX 9VM7XXX 9VMJXXX 9VMQXXX 9VMDXXX xxx length in m; other designs with other connectors on request 7

128 8FLine FLine and FLine smart multifunctional housing engineering FLine and FLine smart patch and splice housings can be used in all areas of in-house data cabling. The components are designed in such a way that speed and reliability are ensured in initial installation, maintenance and extensions. FLine patch and splice housings A replaceable cable entry on the back offers the user all the freedom he requires during installation, no matter whether a straight cable entry, a angled entry or breakout cable support is required. These parts can be replaced easily on location. FLine smart patch and splice housings FLine smart panel engineering differs in design due to a prespecified straight cable and distribution head entry (VKT). Here it is possible to mount up to four PG glands or two distribution heads. Facts which guarantee rapid and reliable initial installation: General Standard versions of the housings are available as or U The front panel is light grey, RAL 70. One U can be equipped with up to x SC-Duplex, x LC-Duplex, x MT_RJ, x E,000, x ST, x FC couplings The body of the housing is made of aluminium, ensuring low weight Exchangeable front panels to accommodate all usual fibre optic couplings The couplings are premounted The admissible bending radii and the ease of assembly are observed even at high packing densities A telescopic extension makes the connecting components easy to access for the purposes of measurements and maintenance work Splice housings Splice cassettes with pigtails already included The wires in the splice cassette are ready for splicing Pigtails are coloured (primary and secondary coating) according to the DIN IEC 600 colour code The pigtails are marked (primary and secondary coating) according to the DIN IEC 600 colour code. The result is rapid, safe assembly as it is no longer necessary to mark the individual pigtails Patch housings The strain relief of the distribution head is based on fixing the distribution head into a V groove immediately on the housing. This means that no other complicated fixing measures are required for the distribution head on the housing The distribution head of the ready-made trunk is secured on the housing to prevent twisting

129 FLine patch/splice housing, telescopic FLine splice housing FLine patch housing 9" housing, / U Characteristics: Installation of a maximum of fibre optic cables with a maximum total of 8 fibres Body of housing made of aluminium, exchangeable front panel made of sheet steel Telescopic, extension depth at least 00 mm Colour of front panel: light grey, RAL 70 Cable entry at an angle of for better cable management Strain relief for the ready-made distribution head on the housing or PG gland for cable entries Dust protection Splice cassette with coloured pigtails, Gigabit Ethernet fibres (MM) Pigtail colour code: E9 0/ according to DIN IEC 600 G0/ according to DIN IEC 600 G6,/ green Pigtails already inserted into splice cassette, splice protector Height: mm ( U) Width: 8 mm (9") Depth: 8 mm Weight:. kg Screen-printed markings: Channel - / -, A/B coding with SC/ST/FC components FLine housing FLine breakout housing Components: Available with up to slots or without components The following couplings can be used: SC-Duplex/SC-Duplex FC-PC, FC-PC(HRL) (SM) ST/ST E,000/E,000 E,000HRL/E,000HRL (SM) MT-RJ/MT-RJ (MM) LC-Duplex Accessories: Blind plug for front panel, Splice protector (maximum of pcs. in one splice cassette) 9

130 0FLine FLine splice housing, telescopic Single-mode standard: insertion losses: < 0. db; return losses: > 0 db No. of Fibres SC-DX ST E,000 E,000HRL FC-PC FC-PC HRL (Met/Cer) (Met/Cer) (Plastic/Cer) (Plastic/Cer) (Met/Cer) (Met/Cer) 9FX900 9FX90 9FX90 9FX906 9FX900 9FX90 8 9FX900 9FX90 9FX90 9FX906 9FX900 9FX90 9FX9060 9FX906 9FX906 9FX9066 9FX9060 9FX906 9FX90 9FX9 9FX9 9FX96 9FX90 9FX9 8 9FX90* 9FX9* 9FX9* 9FX96* 9FX90* 9FX9* FLine 0, Multimode G0/ OM: insertion losses: < 0. db; return losses: > db No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FX00 9FX00 9FX0 9FX0 9FX07 9FX0 8 9FX00 9FX00 9FX0 9FX0 9FX07 9FX0 9FX060 9FX060 9FX06 9FX06 9FX067 9FX06 9FX0 9FX0 9FX 9FX 9FX7 9FX 8 9FX0* 9FX0* 9FX* 9FX* 9FX7 9FX FLine 00, Multimode G0/ OM: insertion losses: < 0. db; return losses: > db No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FXB00 9FXB0 8 9FXB00 9FXB0 9FXB060 9FXB06 9FXB0 9FXB 8 9FXB0* 9FXB FLine 0, Multimode G0/ OM e : insertion losses: < 0. db; return losses: > db No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FXD00 9FXD0 8 9FXD00 9FXD0 9FXD060 9FXD06 9FXD0 9FXD 8 9FXD0* 9FXD Multimode G6,/ OM, Standard: insertion losses: < 0. db; return losses: > db No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FX600 9FX600 9FX60 9FX60 9FX607 9FX60 8 9FX600 9FX600 9FX60 9FX60 9FX607 9FX60 9FX6060 9FX6060 9FX606 9FX606 9FX6067 9FX606 9FX60 9FX60 9FX6 9FX6 9FX67 9FX6 8 9FX60* 9FX60* 9FX6* 9FX6* 9FX67 9FX6 *U version, other or hybrid versions available on request Included in delivery: mounting, splice box(es) with cover, splice protector with holder, xpg6 gland, pigtails marked (primary and secondary coating) and plugged into couplings ready for splicing, possibly with blind plugs

131 FLine distribution panel, telescopic Single-mode-standard No. of Fibres SC-DX ST E,000 E,000HRL FC-PC FC-PC HRL (Met/Cer) (Met/Cer) (Plastic/Cer) (Plastic/Cer) (Met/Cer) (Met/Cer) 9FV900 9FV90 9FV90 9FV906 9FV900 9FV90 8 9FV900 9FV90 9FV90 9FV906 9FV900 9FV90 9FV9060 9FV906 9FV906 9FV9066 9FV9060 9FV906 9FV90 9FV9 9FV9 9FV96 9FV90 9FV9 8 9FV90* 9FV9* 9FV9* 9FV96* 9FV90* 9FV9* FLine housing FLine 0, FLine 00, FLine 0, Multimode-G0, G6. No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FV900 9FVM00 9FV90 9FVM0 9FVM07 9FVM0 8 9FV900 9FVM00 9FV90 9FVM0 9FVM07 9FVM0 9FV9060 9FVM060 9FV906 9FVM06 9FVM067 9FVM06 9FV90 9FVM0 9FV9 9FVM 9FVM7 9FVM 8 9FV90* 9FVM0* 9FV9* 9FVM* 9FVM7 9FVM *U version, other or hybrid versions available on request Included in delivery: mounting, ready-made holder, possibly with blind plugs

132 FLine FLine patch/splice housing, fixed 9" housing, / U Characteristics: Installation of a maximum of fibre optic cables with a maximum total of 8 fibres Body of housing made of aluminium, exchangeable front panel made of sheet steel Colour of front panel: light grey, RAL 70 Cable entry at angle for better cable management Strain relief for the ready-made distribution head on the housing or PG gland for cable entries Dust protection Splice cassette with coloured pigtails, Gigabit Ethernet fibres (MM) Pigtail colour code: E9 0/ according to DIN IEC 600 G0/ according to DIN IEC 600 G6./ green Pigtails already inserted into splice cassette, splice protector FLine patch housing, fixed Height: mm ( U) Width: 8 mm (9") Depth: 0 mm Weight:. kg Screen-printed markings: Channel - / -, A/B coding with SC/ST/FC components Components: Available with up to slots or without components The following couplings can be used: SC-Duplex/SC-Duplex FC-PC, FC-PC(HRL) (SM) ST/ST E,000/E,000 E,000HRL/E,000HRL (SM) MT-RJ/MT-RJ (MM) LC-Duplex Accessories: Blind plug for front panel, splice protector (maximum of pcs. in one splice cassette) Single-mode standard: No. of Fibres SC-DX ST E,000 E,000HRL FC-PC FC-PC HRL (Met/Cer) (Met/Cer) (Plastic/Cer) (Plastic/Cer) (Met/Cer) (Met/Cer) 9FW900 9FW90 9FW90 9FW906 9FW900 9FW90 8 9FW900 9FW90 9FW90 9FW906 9FW900 9FW90 9FW9060 9FW906 9FW906 9FW9066 9FW9060 9FW906 9FW90 9FW9 9FW9 9FW96 9FW90 9FW9 8 9FW90* 9FW9* 9FW9* 9FW96* 9FW90* 9FW9* FLine 0, FLine 00, FLine 0, Multimode-G0, G6. No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FW900 9FWM00 9FW90 9FWM0 9FWM07 9FWM0 8 9FW900 9FWM00 9FW90 9FWM0 9FWM07 9FWM0 9FW9060 9FWM060 9FW906 9FWM06 9FWM067 9FWM06 9FW90 9FWM0 9FW9 9FWM 9FWM7 9FWM 8 9FW90* 9FWM0* 9FW9* 9FWM* 9FWM7 9FWM *U version, other or hybrid versions available on request Included in delivery: mounting, ready-made holder, possibly with blind plugs

133 FLine splice housing, fixed Single-mode E9..0/, insertion losses: < 0. db; return losses: > 0 db No. of Fibres SC-DX ST E,000 E,000HRL FC-PC FC-PC HRL (Met/Cer) (Met/Cer) (Plastic/Cer) (Plastic/Cer) (Met/Cer) (Met/Cer) 9FY900 9FY90 9FY90 9FY906 9FY900 9FY90 8 9FY900 9FY90 9FY90 9FY906 9FY900 9FY90 9FY9060 9FY906 9FY906 9FY9066 9FY9060 9FY906 9FY90 9FY9 9FY9 9FY96 9FY90 9FY9 8 9FY90* 9FY9* 9FY9* 9FY96* 9FY90* 9FY9* FLine housing FLine 0, Multimode G0/ OM: insertion losses: < 0. db; return losses: > db No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FY00 9FY00 9FY0 9FY0 9FY07 9FY0 8 9FY00 9FY00 9FY0 9FY0 9FY07 9FY0 9FY060 9FY060 9FY06 9FY06 9FY067 9FY06 9FY0 9FY0 9FY 9FY 9FY7 9FY 8 9FY0* 9FY0* 9FY* 9FY* 9FY7 9FY FLine 00, Multimode G0/ OM: insertion losses: < 0. db; return losses: > db No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FYB00 9FYB0 8 9FYB00 9FYB0 9FYB060 9FYB06 9FYB0 9FYB 8 9FYB0* 9FYB FLine 0, Multimode G0/ OM e : insertion losses: < 0. db; return losses: > db No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FYD00 9FYD0 8 9FYD00 9FYD0 9FYD060 9FYD06 9FYD0 9FYD 8 9FYD0* 9FYD Multimode G6,/ OM, standard: insertion losses: < 0. db; return losses: > db No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FY600 9FY600 9FY60 9FY60 9FY607 9FY60 8 9FY600 9FY600 9FY60 9FY60 9FY607 9FY60 9FY6060 9FY6060 9FY606 9FY606 9FY6067 9FY606 9FY60 9FY60 9FY6 9FY6 9FY67 9FY6 8 9FY60* 9FY60* 9FY6* 9FY6* 9FY67 9FY6 *Model with U; other or mixed designs available on request Included in delivery: assembly, splice cassette(s) with cover, splice protector with holder, xpg6 gland, pigtails marked and plugged into couplings ready for splicing, possibly blind plugs.

134 FLine FLine patch/splice housing smart, telescopic 9" housing, / U Characteristics: Installation of a maximum of fibre optic cables with a maximum total of 8 fibres Body of housing made of aluminium, exchangeable front panel made of sheet steel Telescopic extension, extension depth at least 00 mm Colour of front panel: grey, RAL 70 Strain relief for the ready made distribution head on the housing or PG gland for cable entries Dust protection Splice cassette with coloured pigtails, Gigabit Ethernet fibres (MM) Pigtail colour code: E9 0/ according to DIN IEC 600 G0/ according to DIN IEC 600 G6./ green Pigtails already inserted into splice cassette, splice protector FLine patch/splice housing, telescopic Height: mm ( U) Width: 8 mm (9") Depth: 8 mm Weight:. kg Screen-printed markings: Channel - / -, A/B coding with SC/ST/FC components Components: Available with up to slots or without components The following couplings can be used: SC-Duplex/SC-Duplex FC-PC, FC-PC(HRL) (SM) ST/ST E,000/E,000 E,000HRL/E,000HRL (SM) MT-RJ/MT-RJ (MM) LC-Duplex Accessories: Blind plug for front panel, splice protector (maximum of pcs. in one splice cassette) Single-mode standard: No. of Fibres SC-DX ST E,000 E,000HRL FC-PC FC-PC HRL (Met/Cer) (Met/Cer) (Plastic/Cer) (Plastic/Cer) (Met/Cer) (Met/Cer) 9FF900 9FF90 9FF90 9FF906 9FF900 9FF90 8 9FF900 9FF90 9FF90 9FF906 9FF900 9FF90 9FF9060 9FF906 9FF906 9FF9066 9FF9060 9FF906 9FF90 9FF9 9FF9 9FF96 9FF90 9FF9 8 9FF90* 9FF9* 9FF9* 9FF96* 9FF90* 9FF9* FLine 0, FLine 00, FLine 0, Multimode-G0, G6. No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FF900 9FFM00 9FF90 9FFM0 9FFM07 9FFM0 8 9FF900 9FFM00 9FF90 9FFM0 9FFM07 9FFM0 9FF9060 9FFM060 9FF906 9FFM06 9FFM067 9FFM06 9FF90 9FFM0 9FF9 9FFM 9FFM7 9FFM 8 9FF90* 9FFM0* 9FF9* 9FFM* 9FFM7 9FFM *Model with U; other or mixed designs available on request Included in delivery: assembly, ready-made holder, possibly blind plugs.

135 FLine patch/splice housing smart, telescopic Single-mode E9..0/, insertion losses: < 0. db; return losses: > 0 db No. of Fibres SC-DX ST E,000 E,000HRL FC-PC FC-PC HRL (Met/Cer) (Met/Cer) (Plastic/Cer) (Plastic/Cer) (Met/Cer) (Met/Cer) 9FS900 9FS90 9FS90 9FS906 9FS900 9FS90 8 9FS900 9FS90 9FS90 9FS906 9FS900 9FS90 9FS9060 9FS906 9FS906 9FS9066 9FS9060 9FS906 9FS90 9FS9 9FS9 9FS96 9FS90 9FS9 8 9FS90* 9FS9* 9FS9* 9FS96* 9FS90* 9FS9* FLine housing FLine 0, Multimode G0/ OM:insertion losses: < 0. db; return losses: > db No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FS00 9FS00 9FS0 9FS0 9FS07 9FS0 8 9FS00 9FS00 9FS0 9FS0 9FS07 9FS0 9FS060 9FS060 9FS06 9FS06 9FS067 9FS06 9FS0 9FS0 9FS 9FS 9FS7 9FS 8 9FS0* 9FS0* 9FS* 9FS* 9FS7 9FS FLine 00, Multimode G0/ OM: insertion losses: < 0. db; return losses: > db No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FSB00 9FSB0 8 9FSB00 9FSB0 9FSB060 9FSB06 9FSB0 9FSB 8 9FSB0* 9FSB FLine 0, Multimode G0/ OM e : insertion losses: < 0. db; return losses: > db No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FSD00 9FSD0 8 9FSD00 9FSD0 9FSD060 9FSD06 9FSD0 9FSD 8 9FSD0* 9FSD Multimode G6,/ OM, standard: insertion losses: < 0. db; return losses: > db No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FS600 9FS600 9FS60 9FS60 9FS607 9FS60 8 9FS600 9FS600 9FS60 9FS60 9FS607 9FS60 9FS6060 9FS6060 9FS606 9FS606 9FS6067 9FS606 9FS60 9FS60 9FS6 9FS6 9FS67 9FS6 8 9FS60* 9FS60* 9FS6* 9FS6* 9FS67 9FS6 *Model with U; other or mixed designs available on request Included in delivery: assembly, splice cassette(s) with cover, splice protector with holder, xpg6 gland, pigtails marked and plugged into couplings ready for splicing, possibly blind plugs.

136 6FLine FLine patch/splice housing smart, fixed 9" housing, / U Characteristics: Installation of a maximum of fibre optic cables with a maximum total of 8 fibres Body of housing made of aluminium, exchangeable front panel made of sheet steel Colour of front panel: light grey,ral 70 Strain relief for the ready-made distribution head on the housing or PG gland for cable entries Dust protection Splice cassette with coloured pigtails, Gigabit Ethernet fibres (MM) Pigtail colour code: E9 0/ according to DIN IEC 600 G0/ according to DIN IEC 600 G6./ green Pigtails already inserted into splice cassette, splice protector FLine patch housing smart, fixed Height: mm ( U) Width: 8 mm (9") Depth: 0 mm Weight:. kg Screen-printed markings: Channel - / -, A/B coding with SC/ST/FC components Components: Available with up to slots or without components The following couplings can be used: SC-Duplex/SC-Duplex FC-PC, FC-PC(HRL) (SM) ST/ST E,000/E,000 E,000HRL/E,000HRL (SM) MT-RJ/MT-RJ (MM) LC-Duplex Accessories: Blind plug for front panel, splice protector (maximum of pcs. in one splice cassette) Single-mode standard: No. of Fibres SC-DX ST E,000 E,000HRL FC-PC FC-PC HRL (Met/Cer) (Met/Cer) (Plastic/Cer) (Plastic/Cer) (Met/Cer) (Met/Cer) 9FF900 9FF90 9FF90 9FF906 9FF900 9FF90 8 9FF900 9FF90 9FF90 9FF906 9FF900 9FF90 9FF9060 9FF906 9FF906 9FF9066 9FF9060 9FF906 9FF90 9FF9 9FF9 9FF96 9FF90 9FF9 8 9FF90* 9FF9* 9FF9* 9FF96* 9FF90* 9FF9* FLine 0, FLine 00, FLine 0, Multimode-G0, G6. No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FF900 9FFM00 9FF90 9FFM0 9FFM07 9FFM0 8 9FF900 9FFM00 9FF90 9FFM0 9FFM07 9FFM0 9FF9060 9FFM060 9FF906 9FFM06 9FFM067 9FFM06 9FF90 9FFM0 9FF9 9FFM 9FFM7 9FFM 8 9FF90* 9FFM0* 9FF9* 9FFM* 9FFM7 9FFM *Model with U; other or mixed designs available on request Included in delivery: assembly, ready-made holder, possibly blind plugs.

137 FLine splice housing smart, fixed Single-mode E9..0/, insertion losses: < 0. db; return losses: > 0 db No. of Fibres SC-DX ST E,000 E,000HRL FC-PC FC-PC HRL (Met/Cer) (Met/Cer) (Plastic/Cer) (Plastic/Cer) (Met/Cer) (Met/Cer) 9FG900 9FG90 9FG90 9FG906 9FG900 9FG90 8 9FG900 9FG90 9FG90 9FG906 9FG900 9FG90 9FG9060 9FG906 9FG906 9FG9066 9FG9060 9FG906 9FG90 9FG9 9FG9 9FG96 9FG90 9FG9 8 9FG90* 9FG9* 9FG9* 9FG96* 9FG90* 9FG9* FLine housing FLine 0, Multimode G0/ OM, insertion losses: < 0. db; return losses: > db No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FG00 9FG00 9FG0 9FG0 9FG07 9FG0 8 9FG00 9FG00 9FG0 9FG0 9FG07 9FG0 9FG060 9FG060 9FG06 9FG06 9FG067 9FG06 9FG0 9FG0 9FG 9FG 9FG7 9FG 8 9FG0* 9FG0* 9FG* 9FG* 9FG7 9FG FLine 00, Multimode G0/ OM: insertion losses: < 0. db; return losses: > db No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FGB00 9FGB0 8 9FGB00 9FGB0 9FGB060 9FGB06 9FGB0 9FGB 8 9FGB0* 9FGB FLine 0, Multimode G0/ OM e : insertion losses: < 0. db; return losses: > db No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FGD00 9FGD0 8 9FGD00 9FGD0 9FGD060 9FGD06 9FGD0 9FGD 8 9FGD0* 9FGD Multimode G6,/ OM, standard: insertion losses: < 0. db; return losses: > db No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FG600 9FG600 9FG60 9FG60 9FG607 9FG60 8 9FG600 9FG600 9FG60 9FG60 9FG607 9FG60 9FG6060 9FG6060 9FG606 9FG606 9FG6067 9FG606 9FG60 9FG60 9FG6 9FG6 9FG67 9FG6 8 9FG60* 9FG60* 9FG6* 9FG6* 9FG67 9FG6 *Model with U; other or mixed designs available on request Included in delivery: assembly, splice cassette(s) with cover, splice protector with holder, xpg6 gland, pigtails marked and plugged into couplings ready for splicing (primary and secondary coating), possibly blind plugs. 7

138 8FLine FLine Hybrid FLine Hybrid was developed for special system applications in SANs, LANs and Data Centres where combined fibre optic and copper cabling is used. The Hybrid panel has a high packing density and is easy to mount. The basic housing was designed to accommodate up to four modular ELine 0 RJ, ELine 00 RJ or EC7 jacks and up to x SC-Duplex and up to x LC-Duplex couplings. An optional splice cassette holder allows the entry and processing of up to fibre pigtails. The FLine Hybrid system combines the advantages of fibre optic and copper cabling. FO: high bandwidths long ranges Copper: for data and telecommunications (conventional / Voice over IP Power over LAN Characteristics: Compact design U The front panel is light grey, RAL 70 Exchangeable front panel The front panel can be equipped with up to x ELine 0 RJ, x ELine 00 and x EC7 x SC-Duplex, x LC-Duplex The couplings are premounted Front panel with combined screen-printed for jacks and couplings The body of the housing is made of sheet steel Optional splice insert: The splice insert is detachable Up to two splice cassettes with fibres each can be inserted Splice cassettes with pigtails already included and ready for splicing Pigtails are marked (primary and secondary coating) according to the DIN IEC 600 colour code The result is rapid, safe assembly as it is no longer necessary to mark the individual pigtails FLine Hybrid housings: Front panel with: SC-DX LC-DX Housing 9FJZ000 9FJZ00 Splice insert 9FZZ089 9FZZ089

139 Single-mode E9..0/, insertion losses: < 0. db; return losses >0 db No. of Fibres SC-DX SC-DX SC-DX LC-DX LC-DX (Met/Cer) (Plastic/Cer) (Plastic/PhBz) (Plastic/Cer) (Plastic/PhBz) 6 9FJ900 9FJ900 9FJ900 9FJ90 9FJ906 9FJ9060 9FJ9060 9FJ9060 9FJ906 9FJ9066 9FJ90 9FJ90 9FJ90 9FJ9 9FJ96 FLine 0, Multimode G0/ OMe, insertion losses: < 0. db; return losses > db No. of Fibres SC-DX SC-DX SC-DX LC-DX LC-DX (Met/Cer) (Plastic/Cer) (Plastic/PhBz) (Plastic/Cer) (Plastic/PhBz) FLine Hybrid 6 9FJ900 9FJ900 9FJ900 9FJ90 9FJ906 9FJ9060 9FJ9060 9FJ9060 9FJ906 9FJ9066 9FJ90 9FJ90 9FJ90 9FJ9 9FJ96 FLine 00, Multimode G0/ OM: insertion losses: < 0. db; return losses > db No. of Fibres SC-DX SC-DX SC-DX LC-DX LC-DX (Met/Cer) (Plastic/Cer) (Plastic/PhBz) (Plastic/Cer) (Plastic/PhBz) 6 9FJB00 9FJB00 9FJB00 9FJB0 9FJB06 9FJB060 9FJB060 9FJB060 9FJB06 9FJB066 9FJB0 9FJB0 9FJB0 9FJB 9FJB6 FLine 0, Multimode G0/ OM e : insertion losses: < 0. db; return losses > db No. of Fibres SC-DX SC-DX SC-DX LC-DX LC-DX (Met/Cer) (Plastic/Cer) (Plastic/PhBz) (Plastic/Cer) (Plastic/PhBz) 6 9FJD00 9FJD00 9FJD00 9FJD0 9FJD06 9FJD060 9FJD060 9FJD060 9FJD06 9FJD066 9FJD0 9FJD0 9FJD0 9FJD 9FJD6 Multimode G6,/ OM, standard: insertion losses: < 0. db; return losses > db No. of Fibres SC-DX SC-DX SC-DX LC-DX LC-DX ((Met/Cer) (Plastic/Cer) (Plastic/PhBz) (Plastic/Cer) (Plastic/PhBz) 6 9FJ600 9FJ600 9FJ600 9FJ60 9FJ606 9FJ6060 9FJ6060 9FJ6060 9FJ606 9FJ6066 9FJ60 9FJ60 9FJ60 9FJ6 9FJ66 Available equipped with other components on request. 9

140 0FLine FLine compact high packing density and maximum flexibility FLine compact is a user-friendly fibre optic cable patch system to hold a maximum of up to fibres with conventional couplings like SC, ST, E,000 and even 0 fibres with LC and 88 fibres with MT-RJ. In spite of its compactness, the system offers optimum fibre optic cable management. FLine compact is used when there is little room and maximum flexibility is required (computer centres, subnetworks). Characteristics of FLine compact U (height units) high, DU (division units) deep, aluminium front panels with screen printing (exception for LC, 8 DU) Maximum flexibility through optional equipping with SC, ST, E,000, E,000 HRL, FC-PC, MT-RJ, LC, LC HRL and FC-PC (by the module) Can be equipped with up to modules (0 with LC-Duplex) Protection of pigtails through closable cable management and splice cassettes The pigtails are coloured (primary and secondary coating) according to the DIN IEC 600 colour code for safe and rapid installation The wires in the splice cassette are marked and ready for splicing The couplings can be mounted at any time later Cable management bar The cable management bar can be pulled out to the rear, takes up the filled loose tube reserve loops and serves to fix the fibre optic cables The switching channel on the front panel organises the patch cord guidance while observing the bending radii

141 FLine compact module Characteristics: Installation of a maximum of fibres Body of housing made of sheet steel Front panel made of aluminium Colour of front panel: aluminium With cable management and splice cassette rest With splice cassette incl. pigtails, Gigabit Ethernet fibres (MM) Pigtail colour code: E9 0/ according to DIN IEC 600 G0/ according to DIN IEC 600 G6./ green Pigtails already inserted into splice cassette, splice protector Depth: 0 mm (without components). Protection of pigtails via closable cable management and splice cassettes The wires in the splice cassette are marked and ready for splicing Fixing screws FLine compact Components: Available with up to, 8 or slots or without components The following couplings can be used: SC-Duplex/SC-Duplex FC-PC, FC-PC(HRL) (SM) ST/ST E,000/E,000 E,000HRL/E,000HRL (SM) MT-RJ/MT-RJ (MM) LC-Duplex (8TE) Compact Modul with LC-Duplex 8 TE Accessories: Blind plug for front panel, splice protector

142 FLine FLine compact U/7 DU splice plug-in module Splice solution: Single-mode E9..0/, insertion losses: < 0. db; return losses: > 0 db No. of Fibres SC-DX ST E,000 E,000HRL FC-PC FC-PC HRL (Met/Cer) (Met/Cer) (Plastic/Cer) (Plastic/Cer) (Met/Cer) (Met/Cer) 9FK900 9FK90 9FK90 9FK906 9FK900 9FK90 8 9FK900 9FK90 9FK90 9FK906 9FK900 9FK90 9FK9060 9FK906 9FK906 9FK9066 9FK9060 9FK906 FLine 0, Multimode G0/ OM, insertion losses: < 0. db; return losses: > db No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX* (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FK00 9FK00 9FK0 9FK0 9FK07 9FK0 8 9FK00 9FK00 9FK0 9FK0 9FK07 9FK0 9FK060 9FK060 9FK06 9FK06 9FK067 9FK06 9FK7 9FK FLine 00, Multimode G0/ OM: insertion losses: < 0. db; return losses: > db No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX* (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FKB00 9FKB0 8 9FKB00 9FKB0 9FKB060 9FKB06 9FKB FLine 0, Multimode G0/ OM e : insertion losses: < 0. db; return losses: > db No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX* (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FKD00 9FKD0 8 9FKD00 9FKD0 9FKD060 9FKD06 9FKD Multimode G6./ OM, standard: insertion losses: < 0. db; return losses: > db No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX* (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FK600 9FK600 9FK60 9FK60 9FK607 9FK60 8 9FK600 9FK600 9FK60 9FK60 9FK607 9FK60 9FK6060 9FK6060 9FK606 9FK606 9FK6067 9FK606 9FK67 9FK6 * 8 DU splice plug-in-module Other or mixed designs available on request Included in delivery: assembly, splice cassette(s) with cover, splice protector with holder, pigtails marked and plugged into couplings ready for splicing, possibly blind plugs.

143 FLine compact U/7 DU patch plug-in module Solution for ready-made breakout cables: Single-mode standard: No. of Fibres SC-DX ST E,000 E,000HRL FC-PC FC-PC HRL (Met/Cer) (Met/Cer) (Plastic/Cer) (Plastic/Cer) (Met/Cer) (Met/Cer) 9FKS00 9FKS0 9FKS0 9FKS06 9FKS00 9FKS0 8 9FKS00 9FKS0 9FKS0 9FKS06 9FKS00 9FKS0 9FKS060 9FKS06 9FKS06 9FKS066 9FKS060 9FKS06 FLine compact FLine 0, FLine 00, FLine 0, Multimode-G0, G6. No. of Fibres SC-DX SC-DX ST E,000 MT-RJ LC-DX* (Met/Cer) (Plastic/Cer) (Met/Cer) (Plastic/Cer) (Plastic) (Plastic/Cer) 9FKS00 9FKM00 9FKS0 9FKM0 9FKM07 9FKM0 8 9FKS00 9FKM00 9FKS0 9FKM0 9FKM07 9FKM0 9FKS060 9FKM060 9FKS06 9FKM06 9FKM067 9FKM06 9FKM7 9FKM * 8 DU splice plug-in-module Other or mixed designs available on request Included in delivery: assembly, splice cassette(s) with cover, splice protector with holder, pigtails marked and plugged into couplings ready for splicing, possibly blind plugs. Splice distributor Compact Cable management bar Product description: 9" component chassis, U, 8 DU, mounted and without components Body of housing and front panel made of aluminium Depth: mm (without compact module) Product description: 9" component chassis, U Front panel with patch cord guidance/ cable management Drawer for clear organisation of filled loose tube reserve loops and fixing Drawer can be extended backwards Completely assembled incl. fastening material Colour: light grey, RAL 70 Depth: 0 mm Article number: 9FKZ000 Article number: 9FKZ000

144 FLine FLine patch cords GigaLine DX 00, 00, 6 Ready-made fibre optical duplex cables for patch field and workplace cabling Type: KL-J-V(ZN)H Sheath material: halogen-free, flame-retardant compound Sheath colour: yellow (single-mode), orange (multimode) Single-mode standard: insertion losses: < 0. db; return losses: > 0 db SC-Duplex/SC-Duplex SC-Duplex/ST ST/ST FC-PC 9FP0XXX 9FPXXX 9FPXXX 9FPXXX FC-PC HRL/FC-PC HRL E,000/E,000 E,000 HRL/E,000 HRL LC-DX/LC-DX (mini-zip) 9FP6XXX 9FPXXX 9FPXXX 9FPAXXX (orange) FC-DX/LC-DX (Duplex) LC-DX/SC-Duplex (mini-zip) LC-DX/SC-Duplex (Duplex) LC-DX/LC-DX (mini-zip) 9FPXXXX (yellow) 9FPXXXX (yellow) 9FPFXXX (yellow) 9FPZXXX (yellow) FLine 0, Multimode G0/ OM: insertion losses: < 0. db; return losses: > db SC-Duplex/SC-Duplex SC-Duplex/ST ST/ST E,000/E,000 9FP0XXX 9FP0XXX 9FP08XXX 9FPXXX MT-RJ/MT-RJ SC-Duplex/MT-RJ LC-DX/LC-DX (mini-zip) LC-DX/LC-DX (Duplex) 9FPXXX 9FP7XXX 9FPAXXX 9FPCXXX LC-DX/MT-RJ (mini-zip) SC-Duplex/LC-DX (mini-zip) SC-Duplex/LC-DX (Duplex) ST/LC-DX (Duplex) 9FPIXXX 9FP7XXX 9FPDXXX 9FPJXXX FLine, Multimode G0/ OM: insertion losses: < 0. db; return losses: > db SC-Duplex/SC-Duplex SC-Duplex/ST ST/ST E,000/E,000 9FPXXX 9FPXXX 9FPTXXX 9FPFXXX LC-DX/LC-DX (Duplex) LC-DX/LC-DX (mini-zip) SC-Duplex/LC-DX (Duplex) ST/LC-DX (Duplex) 9FPGXXX 9FPLXXX 9FPYXXX 9FPAXXX FLine 00, Multimode G0/ OM: insertion losses: < 0. db; return losses: > db SC-Duplex/SC-Duplex 9FPCXXX LC-DX/LC-DX 9FPYXXX FLine 0, Multimode G0/ OM e : insertion losses: < 0. db; return losses: > db SC-Duplex/SC-Duplex 9FPCXXX LC-DX/LC-DX 9FPYXXX Multimode G6,/ OM, standard: insertion losses: < 0. db; return losses: > db SC-Duplex/SC-Duplex SC-Duplex/ST ST/ST E,000/E,000 9FP0XXX 9FP06XXX 9FP09XXX 9FPXXX MT-RJ/MT-RJ SC-Duplex/MT-RJ LC-DX/LC-DX (mini-zip) SC-Duplex/LC-DX (mini-zip) 9FPXXX 9FP8XXX 9FP6AXXX 9FP6XXXX XXX length in decimetres Other or mixed designs available on request Example: KL-J-V(ZN)H E9 0/ with SC-Duplex/SC-Duplex ready-made, length: meters: 9FP000

145 FLine office and floor distributors multifunctional housings for FTTD/FTTO cabling Network installations are increasingly being implemented with disturbance-proof fibre optic systems technology with future capabilities. This allows EMC problems as well as different earthing potentials to be avoided for cabling reaching through whole buildings. When a fibre optic cabling with a star structure is used in a building, the long ranges involved make it possible to dispense with active components on the individual floors. 9" distributor cabinets and separate security areas (rooms) are no longer necessary. The space-saving office and floor cables are perfectly suited for the transitions from high-fibre backbone cables to breakout cables for workplace cabling. They are easy to install and offer space-saving organisation and optimum protection for FO systems engineering. Characteristics which ensure a high degree of flexibility The FLine office and floor distributors can be optionally equipped with splice cassettes and/or distributor plates for taking up fibre optical couplings. Later modifications to the components used are possible at any time Takes up a maximum of up to 9 fibres The pigtails are coloured (primary and secondary coating) according to the DIN IEC 600 colour code for safe and reliable installation The pigtails in the splice cassette are ready for splicing The arriving and departing fibre optic cables are fixed to a strain relief strip in the housing The cable entries are sealed via brush strips or PG glands Housing with two pivoted doors, lockable Housing colour: light grey, RAL 70 FLine office and floor distributors

146 6FLine FLine office and floor distributors multifunctional housings for FTTD/FTTO cabling Size A: 00 x 0 x 0 mm The wall distributor/splice box can be equipped with the following components: Up to 8 splice cassettes with a total of 96 fibres One integrated coupling panel can be equipped with up to 8 couplings for fibre optic connectors Optionally, different cable entry modules can be used ( x at top and x at bottom) light grey, RAL 70 Size B: 0 x 0 x 0 mm The wall distributor/splice box can be equipped with the following components: Up to 6 splice cassettes with a total of 9 fibres One integrated coupling panel can be equipped with up to 96 couplings for fibre optic plug connectors Optionally, different cable entry modules can be used ( x at top and x at bottom) light grey, RAL 70 In general: Optionally, different cable entry modules can be used ( x at top at x at bottom) - Brush strip - x PG 6 - x PG Scope of delivery: Fibre optical wall distributor/splice box housing empty, without cable entry modules with standard closing cylinder Coupling panel Cable entry modules Accessories: Coupling panel to take up ST, SC-Duplex, E,000, LC-Duplex, MT-RJ Splice cassette with holder and cover Pigtails Crimp/shrink splice protector Cable guide bar with velcro band Dummy plates Office/wall distributor/splice box Article no. Office/wall distributor/splice box Article no. Size A: 00 x 0 x 0 mm 9FW08V Size B: 0 x 0 x 0 mm 9FW096V Housing empty Housing empty Coupling panel for a max. of x SC-Duplex 9FZW0 for a max. of x SC-Duplex 9FZW0 for a max. of x ST 9FZW for a max. of 8 x ST 9FZW x FC-PC 8 x FC-PC for a max. of x E,000, 9FZW for a max. of 8 x E,000 9FZW x LC-Duplex x LC-Duplex x MT-RJ 8 x MT-RJ

147 Couplings Multimode Single-mode SC-Duplex 9FZ9000 SC-Duplex 9FZ9000 ST 9FZ900 ST 9FZ900 LC-Duplex 9FZM00 LC-Duplex 9FZ900 E,000 9FZM00 E,000 9FZ900 MT-RJ 9FZM007 MT-RJ 9FZ9007 FC-PC 9FZM000 FC-PC 9FZ9000 Cable entry modules x PG 6 9FZZ0069 x PG 9FZZ0070 Brush strip 9FZZ007 Dummy plate 9FZZ007 Cable guide bar with velcro band 9FZZ007 Splice cassette 9FZZ000 Cover for the splice cassette 9FZZ00 Splice protector 9FZZ0006 Splice protector holder 9FZZ0007 Splice cassettes with inserted pigtails Article number FLine 0, Multimode G 0/, insertion losses < 0. db; return losses > db OMe Splice cassette with x SC pigtails 9F060 Splice cassette with x ST pigtails 9F060 Splice cassette with x LC pigtails 9F06 Splice cassette with x E,000 pigtails 9F06 Splice cassette with x FC-PC pigtails 9F060 FLine office and floor distributors FLine 00, Multimode G 0/, insertion losses < 0. db; return losses > db OM Splice cassette with x SC pigtails Splice cassette with x LC pigtails 9FB060 9FB06 FLine 0, Multimode G 0 /, insertion losses < 0. db; return losses > db OMe Splice cassette with x SC pigtails Splice cassette with x LC pigtails 9FD060 9FD06 Single-mode E 9...0/, insertion losses < 0. db, return losses > 0 db Splice cassette with x SC pigtails Splice cassette with x ST pigtails Splice cassette with x LC pigtails Splice cassette with x E,000 HRL pigtails Splice cassette with x E,000 pigtails Splice cassette with x FC-PC pigtails Splice cassette with x FC-PC-HRL pigtails 9F9060 9F9060 9F906 9F9066 9F906 9F9060 9F906 7

148 8FLine FLine the complete fibre-to-the-desk system Compact fibre optical connection engineering high performance, immunity to disturbances, future capabilities Of course, the FLine system also includes comprehensive connectivity solutions for fibre-to-the-desk. Here it is possible to use a wide range of outlets with the corresponding materials for installation in ducts and floorbox solutions Lifetime (years) ,0 0,000 0 FLine UP outlet 0 0 Bendingradius (mm) As a result of a specific outlet design, bending never goes below the admissible bending radii of the fibres, thus ensuring that the fibre keeps its full functionality even in the long term. A defined bending radius of the fibre ensures the lifetime An effective strain relief for cables and pigtails and clean guidance within the outlet ensure minimum strain on the fibre and preservation of the physical characteristics The dimensions of the outlets are as small as possible years FLine UP outlet loops loops loops loops loop The UP outlet can be installed in ducts or concealed mounting can be used. The special features of this professional version are as follows: It can be equipped with up to two duplex or simplex couplings Possible types of coupling: SC-Duplex, ST-Simplex, E,000, LC-Duplex The bending radius of the fibre of at least 0 mm is ensured by the cable reservoir and the cable guide The outlet has a downward inclination of 0. This ensures optimum protection against mechanical stress. The universal carrying frame is compatible with usual mounting cups All current connecting techniques are supported: - Mounting of fibre optical plugs on location - Use of ready-made cables - Splicing of pigtails

149 FLine outlets FLine outlet Product description: FLine cable reservoir KR Product description: FLine cable guide KF Product description: FLine outlets For mounting in parapet ducts and for underfloor mounting Termination of up to channels/ 6 fibres Outlet direction: downwards at an angle of 0 Bending radius > 0 mm in conjunction with cable reservoir KR or cable guide KF Marking insert enclosed Delivery: completely equipped with all components Colour: pearl white, RAL 0 For UP jack to take up excessive cable lengths and/or safety reserves (at least x m at an external diameter of mm) Minimum bending radius > 0 mm Direction-independent cable entry with cable tie strain relief on input and output side FLine cable reservoir KR Installation height 0 mm Installation height mm For UP FO jack to comply with the minimum bending radii for FO cables (> 0 mm) in conjunction with assembly holder FLine cable guide KF Article number: 9FK00 Pcs. per packing unit: Article number: 9FK0007/9ZK0008 Pcs. per packing unit: Article number: 9FK0009 Pcs. per packing unit: 0 FLine EK outlet FLine EK outlet The advantage of the EK outlet is its compact design. It can be installed in ducts in a horizontal or vertical position. The EK outlet has the following characteristics: It can be equipped with up to one duplex coupling or two simplex couplings Possible types of coupling: SC-Duplex, ST-Simplex, E,000, LC-Duplex The integrated cable guide ensures compliance with the admissible bending radius The universal central piece can be combined with various different switch programs Ready-mounted plugs as well as plugs mounted on location can be used 9

150 0FLine FLine outlets FLine EK outlet Product description: For horizontal and vertical mounting in parapet ducts, termination of channels/ fibres Outlet direction: downwards at an angle of, defined bending radius in conjunction with suitable assembly holder MH Cable tie strain relief Central piece 0 x 0 mm according to DIN 07 Part, 989 Colour: pearl white, RAL 0 Article number: 9FK000 Pcs. per packing unit: Designation, coupling ST/ST Monomode, ceramic SC/ST Monomode, ceramic SC/SC Monomode, ceramic ST/ST Multimode, ceramic SC/ST Multimode, ceramic FLine assembly holder MH Product description: For EK or UP outlet in conjunction with cable guide KF Horizontal mounting Suitable for all Tehalit duct systems and Ackermann Te li ko (WIK + SIS) Installation height 0 mm Installation height mm Article number: 9FK00/9FK00 Pcs. per packing unit: 0 Article No. 9FK000 9FK00 9FK00 9FK00 9FK00 Installation systems for Ackermann floorbox GES 6 and GES 9 More and more frequently, modern office infrastructures are being based on flexible underfloor systems (double floors, duct systems). KERPEN has followed the leading manufacturers of these systems and developed suitable connecting components. Designation, coupling SC/SC Multimode, ceramic ST/ST Multimode, PhBz SC/ST Multimode, PhBz SC/SC Multimode, PhBz FLine assembly holder MH Product description: For EK or UP outlet in conjunction with cable guide KF Horizontal mounting Suitable for all Tehalit duct systems and Ackermann Te li ko (WIK + SIS) Installation height 0 mm Installation height mm Article number: 9FK006/9FK007 Pcs. per packing unit: 0 Article No. 9FK00 9FK006 9FK007 9FK008 Product features: The device cup can take up X SC Duplex, x E,000, x MT-RJ and X LC Duplex The device cup consists of. mm sheet steel Surface powder-coated black, RAL 900 Self-adhesive marking strips for marking as required

151 Solution for ready-made cables FLine device cup (dual) Product description: For taking up the mounting plates for fibre optic couplings For Ackermann floorboxes GES 6 Article number: 9ZE6000 FLine device cup (triple) Product description: For taking up the mounting plates for fibre optic couplings (as in examples on top right) For Ackermann floorboxes GES 6 Article number: 9ZE6000 FLine adjustable cable strain relief Product description: For up to 9 individual cables Article number: 9ZE6000 FLine floorbox solutions FLine mounting plate FLine mounting plate Product description: For up to x SC-Duplex couplings Product description: For up to x LC/Duplex and/or x E,000 Simplex Article number: 9FZZ008 Article number: 9FZZ0079 Floorbox solutions for splices (pigtails) FLine cable management module FLine splice tray with splice holder Product description: For storing the wires and for the strain relief of the fibre optic cables Product description: For x splice protector Article number (GES 9): 9FZZ0080 Article number (GES 9): 9FZZ008 Article number (GES 6): 9FZZ008 Article number (GES 6): 9FZZ008

152 Services Here's the information you'll find under: Specifications and tender texts Planning documents Certificates Link Matrix Warranty programme References Technical articles Certification programme KERPEN Trained Networker Seminars and roadshows Up-to-date information If you save on the cabling Active components 7% In network installation, the passive cabling only accounts for about % of the costs, whereas the active components have a share of 7 %. About one third of the costs ( %) are invested in the workstation and the software swallows up the lion's share with %. Taking into account that the passive cabling has a product lifetime of years, it's clear for all to see: If you save on the cabling, you're saving in the wrong place! Workstations % Cabling % Software % %

153 Notes

154 Notes

155

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2 Page 1/7 Illustrations Principle diagram See enlarged drawings at the end of document Product specification 10 GBit installation cable, simplex installation cable Cat.7A AWG 22 S/FTP with wires shielded

More information

COPPER + LWL RAW CABLES

COPPER + LWL RAW CABLES COPPER + LWL RAW Twisted Pair Cables... 112 TV/SAT Cables... 116 Fiber Optic Raw Cables... 120 DIGITUS CAT 7 twisted pair installation cable 4x2xAWG23 S-FTP CAT 7 1000 MHz LSZH installation cable For installation

More information

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft Page 1/6 MC GC0 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft 18427034141 Illustrations Principle diagram Product specification 10 GBit installation cable, simplex installation cable Cat.7 AWG 23 S/FTP with wires

More information

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft Page 1/7 Illustrations Principle diagram Product specification 10 GBit installation cable, duplex installation cable Cat.7A AWG 22 S/FTP with wires shielded in pairs 2x4 pairs (PiMF) pair shield: plastic

More information

NETWORK CONNECTIVITY SYSTEMS

NETWORK CONNECTIVITY SYSTEMS NETWORK CONNECTIVITY SYSTEMS Installation Cable KS-STP Category 7 Installation Cable Certificates 10GBaseT FTP Category 6 Installation Cable UTP Category 6 Installation Cable UTP Category 5E Installation

More information

technical bulletin UTP vs STP Shielded data cables make the grade Unshielded data cables reach the limits of their performance

technical bulletin UTP vs STP Shielded data cables make the grade Unshielded data cables reach the limits of their performance technical bulletin Data communication technology 12/2015 UTP vs STP Shielded data cables make the grade Unshielded data cables reach the limits of their performance Business Unit Datacom LEONI Kerpen GmbH

More information

Data sheet Patch cord Cat.6 A AWG m yellow

Data sheet Patch cord Cat.6 A AWG m yellow Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification especially suitable for shielded and unshielded class E A systems fully shielded Cat.6 A patch

More information

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations Page 1/7 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection cable drag chain suitable Cat.6A, 8 pole, X-coded

More information

Information technology. Generic cabling systems, General requirements

Information technology. Generic cabling systems, General requirements KRAMER WELL CONNECTED WITH KRAMER BCLS-33OR-5 Al-Mylar Conductor CAT6A F/UTP LSZH Cable Drain Wire Kramer s BCLS-33OR is a high performance CAT6A F/UTP cable designed for IT, LAN and Ethernet installations.

More information

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4 Wiking Ship Hybrid Cable Application Hybrid cable for shipboard applications DATA ELEMENT Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T

More information

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation. Telecommunication and fire alarm cables For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation. J-YY Bd 14 J-YY BMK 15 J-Y(St)Y Lg 16 J-Y(St)Y

More information

CAT 5e UTP Cable: NETSET BOX [305m], indoor

CAT 5e UTP Cable: NETSET BOX [305m], indoor Code: E08_05 CAT 5e UTP Cable: NETSET BOX [05m], indoor NETSET BOX UTP 5e Ethernet cable far exceeds the requirements for Category 5e twisted pair cables. View of the cable box - inside 05m of the cable.

More information

Selection table for flat & ribbon cables

Selection table for flat & ribbon cables Just click on the products in the selection table. Click on the HELUKABEL logo at the end of the page to go back. Cables & Wires Selection table for flat & ribbon cables www.helukabel.com FLAT & RIBBON

More information

Category 6 A F/FTP Euroclass C ca Cables

Category 6 A F/FTP Euroclass C ca Cables Category 6 A F/FTP Euroclass C ca s Datasheet: GD103266v2 APPLICATION The Brand-Rex AC6F/FTP C ca cables are compliant with the European Construction Products Regulation, achieving Euroclass level C ca

More information

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description Description Cat 8 Filler Cat.8.2 S/FTP Horizontal cables (x6) Fan-Out Cables Cat 8 STP Keystones TRUNK CABLE SECTION VIEW Assembly Isometric Front View RiT s Copper Install & Go System provides a pre-terminated

More information

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking A Technical data Special PVC control cables, adapted to DINVDE0 part3 Temperature range flexing -5 C ) to +0 C fixed installation

More information

Category 6 UTP EuroClass C ca Cables

Category 6 UTP EuroClass C ca Cables Category 6 UTP EuroClass C ca Cables Datasheet: GD103704v1 APPLICATION Brand-Rex Cat6Plus C6U cables exceed the Category 6 performance standards. They are rated to 250MHz and are suitable for use in all

More information

Medium Voltage Power Cables

Medium Voltage Power Cables N2XSY 6/0, /20, /30 NA2XSY 6/0, /20, /30 N2XS2Y 6/0, /20, /30 NA2XS2Y 6/0, /20, /30 N2XS(F)2Y 6/0, /20, /30 NA2XS(F)2Y 6/0, /20, /30 N2XSEY 3 x 6/0 Medium Voltage Power Cables Photo: HELUKABEL Q 47 Medium

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 Description: Banana Peel Composite - (2) Cat 5e 4-pair 24 AWG unshielded plus (2) Series 6 Coax with Duobond IV Quad shield, polyolefin insulation on the

More information

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications. Industrial Ethernet Petrol Forecourt Cable (Solid) 3014P24S1001 Industrial Ethernet Petrol Forecourt Cable (Solid) 3014P24S1001-10 Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

More information

MULTIMEDIA CABLE H6091ZHB

MULTIMEDIA CABLE H6091ZHB CAVEL News MULTIMEDIA CABLE H6091ZHB MULTIMEDIA CABLE H6091ZHB Multimedia is a must in the modern way of life. Growing communication needs in any environment whether at home or the office the connection

More information

Install & Go Cat.8 STP Trunk Cable Assembly Description

Install & Go Cat.8 STP Trunk Cable Assembly Description Description Cat 8 Filler Cat.8.2 S/FTP Horizontal cables (x6) Fan-Out Cables Cat 8 STP Keystones TRUNK CABLE SECTION VIEW Assembly Isometric Front View RiT s Copper Install & Go System provides a pre-terminated

More information

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm name: TKF article number: 10305 description Nr.: POE- PS- 10305 PT F F F 800 B C 1 2 3 4 5 6 7 Assembly: 1. Primary tube 5 mm 2. CAT 5 E FTP cable 3. CAT 5 E FTP cable 4. Bus cable 5. Coax 9 cable 6. Separation

More information

H155A02. Product Description. Product Specifications. Technical Specifications. Application. Bend Radius. CCB-Sub-Crush Resistance.

H155A02. Product Description. Product Specifications. Technical Specifications. Application. Bend Radius. CCB-Sub-Crush Resistance. H155A02 Part Number: H155A02 COAX RF H155 FRNC Product Description COAX RF H155 FRNC Product Specifications Application Application 1: Application 2: 50 Ohm low loss coaxial transmission cable designed

More information

ACR (Attenuation to Crosstalk Ratio) ACR-F. Alien Crosstalk. Attenuation (signal attenuation, conductor attenuation)

ACR (Attenuation to Crosstalk Ratio) ACR-F. Alien Crosstalk. Attenuation (signal attenuation, conductor attenuation) ACR (Attenuation to Crosstalk Ratio) The distance between the wanted signal and the interfering signal (ACR) is an important factor for the transmission quality. To ensure a faultless transmission, the

More information

Product Bulletin. Belden DataTwist 4800 Cables

Product Bulletin. Belden DataTwist 4800 Cables Product Bulletin PB 296 Belden DataTwist 4800 Cables DataTwist 4800 UTP Cables provide significant headroom and robust data transmission performance for today s most demanding applications. The cables

More information

Cables for data transmission in industrial automation

Cables for data transmission in industrial automation Cables for data transmission in industrial automation The Quality Connection The LEONI Group Cable expertise for the most various industrial markets. LEONI is a leading supplier of cable systems and related

More information

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES FOR CABLE CARRIERS EDITION 09-2012 Durable, reliable, cost-effective

More information

Install & Go SMARTen (Cat.6A) STP Trunk Cable Assembly General

Install & Go SMARTen (Cat.6A) STP Trunk Cable Assembly General Install & Go SMARTen (Cat.6A) STP Trunk General Cat 8 Filler Cat.6A U/FTP Horizontal cables (x6) Fan-Out Cables Cat.6A STP Keystones TRUNK CABLE SECTION VIEW Trunk Isometric Front View RiT s Copper Install

More information

UC DATA CABLES - CAT 5,6, 7 & 8

UC DATA CABLES - CAT 5,6, 7 & 8 UC DATA CABLES - CAT 5,6, 7 & 8 Fast and reliable copper cables for network solutions Connecting communities with communications PRYSMIAN GROUP A MARKET LEADER IN THE TELECOM INDUSTRY As the worldwide

More information

Cables for Data Transmission in Industrial Automation. Fieldbus Cables Copper Cables Fibre Optic Cables

Cables for Data Transmission in Industrial Automation. Fieldbus Cables Copper Cables Fibre Optic Cables Cables for Data Transmission in Industrial Automation Fieldbus Cables Copper Cables Fibre Optic Cables 2 KERPEN GmbH & Co. KG 2005 2.2006 Printing errors excepted. Subject to alteration. Contents Seite

More information

The Quality Connection. Cable and Systems for Rolling Stock Business Unit Rolling Stock

The Quality Connection. Cable and Systems for Rolling Stock Business Unit Rolling Stock The Quality Connection Cable and Systems for Rolling Stock Business Unit Rolling Stock Consulting and Sales Cable solutions Phone +41 (0)62-288-8356 Fax +41 (0)62-288-8383 System solutions Phone +49 (0)9172-6844-11

More information

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors

More information

Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION BUILDING MANAGEMENT SYSTEMS

Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION BUILDING MANAGEMENT SYSTEMS Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION SOLUTIONS COAXIAL CABLES BUILDING MANAGEMENT SYSTEMS BROADCASTING & STUDIO Prysmian Group Linking

More information

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

K20 & L120 LSZH Armoured F/FTP Cat6 Cables K20 & L120 LSZH Armoured F/FTP Cat6 Cables The cables are designed for high speed data transmissions, and are suitable for installations in cable trays or on hooks. RATP CAT6-K20 (for K20 cable) FRANCE

More information

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable ENERGY (N)SHTOEU Low Voltage Reeling Cable Technical Data Type Type designation Approvals/standards Application (N)SHTOEU-J/-O DIN VDE 0250, Part 814; VDE-Reg.-Nr. 7519; GOST R Flexible reeling cable for

More information

Category 7 A /Class F A Products

Category 7 A /Class F A Products CATEGORY 7 A /CLASS F A PRODUCTS Category 7 A /Class F A Products Exceeding ISO/IEC category 7 A /class F A specifications, Siemonʼs fully shielded TERA endto-end cabling solution is the highest-performing,

More information

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified - Screened servo cable for high dynamic power chain application in harsh conditions with UL/CSA AWM and

More information

Ship and Offhsore. Approved cables for ship- and offshoreindustry

Ship and Offhsore. Approved cables for ship- and offshoreindustry Ship and Offhsore Approved cables for ship- and offshoreindustry NEK Kabel AS - Norway. (NEK Sealine Marine products) tel. +47 67 91 21 80 - Firmapost@nek-kabel.no 1 OVER 100 YEARS OF EXPERIENCE 1913-2013

More information

Data sheet C6 A modul K 90 jack - keystone style

Data sheet C6 A modul K 90 jack - keystone style Illustrations Dimensional drawing Cut-out Page 1/7 See enlarged drawings at the end of document Product specification modular Cat.6 A termination unit RJ45 mounting version: Keystone, 90 cable feed solid,

More information

Electric cables. Cranes

Electric cables. Cranes Electric cables. Cranes Electric cables for mobile connections. Aristoncavi spa reserve the right to modify the data in this catalogue without notice. 01/2012 Copyright Drawings and technical descriptions

More information

Data sheet C6 A modul K 180 jack - Keystone style

Data sheet C6 A modul K 180 jack - Keystone style Illustrations Dimensional drawing Cut-out Page 1/7 See enlarged drawings at the end of document Product specification modular Cat.6 A termination unit RJ45 mounting version: Keystone, 180 cable feed solid,

More information

CAT. 5e U/UTP 4x2x24AWG/1 CCA DOUBLE SHEATH

CAT. 5e U/UTP 4x2x24AWG/1 CCA DOUBLE SHEATH CAT. 5e U/UTP 4x2x24AWG/1 CCA DOUBLE SHEATH FIGURE CONSTRUCTION Inner conductor CCA Φ 0.50±0.01mm Insulation Solid HDPE Φ 0.90±0.05mm Color 1 Blue & White/ Blue 2 Orange & White/ Orange 3 Green & White/

More information

Data sheet. C5 RJ45 field plug pro 2P 360 PROFINET. Illustrations P/N 130E405042PE EAN Product specification. Page 1/

Data sheet. C5 RJ45 field plug pro 2P 360 PROFINET. Illustrations P/N 130E405042PE EAN Product specification. Page 1/ Page 1/6 Illustrations Dimensional drawing Wiring See enlarged drawings at the end of document Product specification Cat.5 class D RJ45 plug, 2 pairs, to be assembled in the field fully shielded and multi-port

More information

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or

More information

Copper and Fiber Optic Cables

Copper and Fiber Optic Cables Copper and Fiber Optic Cables Pietro Nicoletti piero[at]studioreti.it Cables-Engl - 1 P. Nicoletti: see note pag. 2 Copyright note These slides are protected by copyright and international treaties. The

More information

Data sheet E-DAT Industry RJ45 plug black Cat.6 Class E A

Data sheet E-DAT Industry RJ45 plug black Cat.6 Class E A Illustrations Dimensional drawing Page 1/7 See enlarged drawings at the end of document Product specification multi-port Cat.6 class E A plug compliance with class E A to ISO/IEC 11801 Ed.2.2:2011-06,

More information

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A Illustrations Dimensional drawing See enlarged drawings at the end of document Product specification multi-port Cat.6 class E A plug to be assembled in the field compliance with class E A to ISO/IEC 11801

More information

TRAXLINE CABLES FOR MOTION

TRAXLINE CABLES FOR MOTION TRAXLINE CABLES FOR MOTION CONTINUOUS BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS TRAXLINE PRE-ASSEMBLED CABLES FOR CABLE CARRIERS EDITION 5-2016 Cost-effective, reliable, durable cables

More information

Fireproof Cables (Fire Resistant LSOH Sheathed Cables) КИФнг(A)-HF for RS485

Fireproof Cables (Fire Resistant LSOH Sheathed Cables) КИФнг(A)-HF for RS485 Content Page Certificates 3 Industrial Cables Production 4-5 Industrial Cables of PJSC «Odeskabel» 6 КИФ-В for RS485 (CAN) КИФ-В 1х2х0,6; КИФ-В 1,5х2х0,6; КИФ-В 2х2х0,6; КИФ-В 3х,2х0,6; КИФ-В 4х2х0,6 8

More information

OPENETICS. P/N E-DAT Industry RJ45 field plug insert Cat.6A. Specialist Manufacturer Voice Data Security.

OPENETICS. P/N E-DAT Industry RJ45 field plug insert Cat.6A. Specialist Manufacturer Voice Data Security. Illustrations Dimensional drawing See enlarged drawings at the end of document Product specification Cat.6 class E A plug to be assembled in the field and mounted in IP67 plug housings of variants 1, 4,

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61156-1 Third edition 2007-06 Multicore and symmetrical pair/quad cables for digital communications Part 1: Generic specification Commission Electrotechnique Internationale International

More information

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s EC 200 EC200 - Rev. 3-23.06.11 Characteristic impedance 50 ± 2 Material copper wire Nominal capacity (pf/m) 80.5 Construction - Relative propagation velocity (%) 83 Diameter (mm) 1.05 Inductance (µh/m)

More information

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications... Content page ❿! Applications... /2 ❿! Construction examples of special cables... /3-6 ❿! S 670 PUR hybrid field bus control cable, suitable for cable tracks UL/CSA... /7 ❿! S 671 PVC hybrid field bus control

More information

Data sheet E-DAT modul 2 port AP Cat.6 A, pearl white

Data sheet E-DAT modul 2 port AP Cat.6 A, pearl white Illustrations Dimensional drawing Wiring Page 1/7 See enlarged drawings at the end of document Product specification surface-mounted termination unit with E-DAT modul component testing for Cat.6 A to ISO/IEC

More information

Data sheet E-DAT Industry RJ45 field plug insert Cat.6 Class E A

Data sheet E-DAT Industry RJ45 field plug insert Cat.6 Class E A Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification Cat.6 class E A plug to be assembled in the field and mounted in IP67 plug housings of variants

More information

Data sheet C6 A RJ45 field plug pro 360

Data sheet C6 A RJ45 field plug pro 360 Illustrations Dimensional drawing See enlarged drawings at the end of document Product specification Cat.6 A class E A RJ45 plug to be assembled in the field fully shielded and multi-port capable variable

More information

Data sheet C6 A RJ45 field plug pro

Data sheet C6 A RJ45 field plug pro Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification Cat.6 A class E A RJ45 plug to be assembled in the field fully shielded and multi-port capable

More information

Railway products. Edition 2014

Railway products. Edition 2014 Railway products Edition 2014 Bridging our technologies Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical interconnectivity components

More information

Data sheet C6 A RJ45 field plug pro 360

Data sheet C6 A RJ45 field plug pro 360 Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification Cat.6 A class E A RJ45 plug to be assembled in the field fully shielded and multi-port capable

More information

Data sheet. E-DAT modul 3 port AP Cat.6A, pure white. Illustrations P/N E EAN Product specification. Page 1/

Data sheet. E-DAT modul 3 port AP Cat.6A, pure white. Illustrations P/N E EAN Product specification. Page 1/ Page 1/7 Illustrations Dimensional drawing Wiring See enlarged drawings at the end of document Product specification surface-mounted termination unit with E-DAT modul component testing for Cat.6A to ISO/IEC

More information

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m Page 1/6 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12-jack to RJ45-plug Ethernet connection line Cat.5, 4-pole, D-coded (IEC

More information

Coaxial Cables Coax Serie. HF Steckverbinder für Mobilfunk-Anwendungen. in Bulk Rings or on Cable Drums

Coaxial Cables Coax Serie. HF Steckverbinder für Mobilfunk-Anwendungen. in Bulk Rings or on Cable Drums 4.3-10 Coax Serie Coaxial Cables HF Steckverbinder für Mobilfunk-Anwendungen in Bulk Rings or on Cable Drums Coaxial Cables In addition to the wide range of coaxial connectors, Telegärtner offers suitable

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 177 2012 Specification for Braided 75 Ω, Mini-Series Quad Shield Coaxial Cable for CMTS and SDI cables NOTICE

More information

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction: Caledonian www.caledonian-cables.co.uk www.caledonian-cables.net Profibus L2 Indoor Application: This system cable is used to interconnect L2-BUS components. This cable is an economical solution for the

More information

Bus Cables HELUKABEL

Bus Cables HELUKABEL Photo: HELUKABEL Bus Cables HELUKABEL Bus technology is being used in an increasing number of industrial applications. This technology can be applied in every branch in industry where processcontrol techniques

More information

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction: Addison www.addison-tech.com www.addison-cables.com Profibus SK Indoor + Outdoor Application: The application of these Profibus SK cables are in the cell and field area, just as for conventional types.

More information

CABLE.

CABLE. CABLE www.pcnet-cable.com.tw sales@pcnet-cable.com.tw PCnet Leading Your Net! PCnet was founded in 1985 and is a leading manufacturer of netwking industries. We provide a complete range of products f structured

More information

Data sheet Cable connector class F A

Data sheet Cable connector class F A Illustrations Dimensional drawing See enlarged drawings at the end of document Product specification cable connector for field assembly Class F A for 8 wire cables to connect / extend / repair / relocate

More information

THE WORLD OF LAPP. Cables for power chains

THE WORLD OF LAPP. Cables for power chains THE WORLD OF LAPP Cables for power chains Tested to breaking (or making) point The new generation of premium cables for highly dynamic applications in power chains is growing ÖLFLEX SERVO FD/CHAIN New

More information

Part Number: 7953A Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor

Part Number: 7953A Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor Part Number: Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor Product Description Four Cat 6 23 AW G solid bare copper conductors, bonded pair polypropylene insulation,

More information

Data sheet C6 A RJ45 field plug pro 360

Data sheet C6 A RJ45 field plug pro 360 Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification Cat.6 A class E A RJ45 plug to be assembled in the field fully shielded and multi-port capable

More information

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive Illustrations Principle diagram Page 1/7 Product specification connection cable for direct connector termination with higher robustness cable structure: I-V(ZN)HH2, duplex patch cable with additional outer

More information

n Proper pin termination at each end n Continuity to the remote end n Shorts between any two or more conductors n Transposed pairs: n Crossed pairs.

n Proper pin termination at each end n Continuity to the remote end n Shorts between any two or more conductors n Transposed pairs: n Crossed pairs. INTRODUCTION Structured Cabling or data cabling (also known Local Area Network or LAN Cabling) is increasing in its deployment for business, commercial and residential use to carry signaling for networks

More information

UTP Cat 5e cable (200 MHz) (PVC sheath)

UTP Cat 5e cable (200 MHz) (PVC sheath) JetLan is the only structured cabling system that includes all the passive components required for the installation or adaptation of your data network, as we include all the different types of high performance

More information

Test Report based on DIN EN ISO/IEC 17025:2005

Test Report based on DIN EN ISO/IEC 17025:2005 Test Report based on DIN EN ISO/IEC 1725:25 GHMT Type Approval 2 Connector Permanent Link, Copper, Class E according ISO/IEC 1181-1 Ed.1. 217-11 Document-no: P4945b-18-E This Test Report with the measurements

More information

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable Rubber Insulation and Rubber Sheathed Application Range Heavy duty flexible cables for medium mechanical stress For dry and wet applications Can be used for domestic electric tools According to HD 516

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 General Description: PTZ (CCTV+Control+Power) Cable, Rated-CM, 1-RG59 20 AWG solid bare copper with foam polyolefin, 95% bare copper braid, 1-22 AWG stranded

More information

Connection technology for wireless communication systems

Connection technology for wireless communication systems Connection technology for wireless communication systems Rosenberger Rosenberger, founded in 1958, is a family owned company and ranks today among the top global manufacturers of high-frequency coaxial

More information

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568B. Illustrations P/N I-B1 EAN Product specification. Page 1/

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568B. Illustrations P/N I-B1 EAN Product specification. Page 1/ Page 1/9 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification modular termination unit Cat.6A, RJ45 component testing for Cat.6A to ISO/IEC 11801

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 Description: Coax (2-1505A Type) 20 AWG BC, GIFPE isulation, Duofoil plus TC braid (95% cv.), PVC inner jackets. Pairs (4-9451 Type): 22 AWG TC, PP insul.,

More information

Data sheet C5 RJ45 field plug pro 2P PROFINET

Data sheet C5 RJ45 field plug pro 2P PROFINET Illustrations Dimensional drawing Page 1/5 See enlarged drawings at the end of document Product specification Cat.5 class D RJ45 plug, 2 pairs, to be assembled in the field fully shielded and multi-port

More information

Understanding and Inspecting THE DIGITAL BUS. by Jim Sparks

Understanding and Inspecting THE DIGITAL BUS. by Jim Sparks Understanding and Inspecting THE DIGITAL BUS by Jim Sparks 1 Means of Avionics Communication Analog Uses variable signals Voltage Amperage Frequency Discrete Changes a signal state Hi or Lo 1 or 0 On or

More information

Amphenol Cable. Features Allows for mass termination Up to 64 conductors

Amphenol Cable. Features Allows for mass termination Up to 64 conductors G80.7mm Economical Flat Ribbon 94V-0 A G80 X X XX X FLAT RIBBON CABLE.7mm Up to 64 conductors VARIATION CODE Blank: Standard PACAGING LENGTH NUMBER OF CONDUCTORS : 500 Feet 09: 9 Position : 400 Feet 4:

More information

SAC-5P- 1,5-PUR/M12FS SH

SAC-5P- 1,5-PUR/M12FS SH Extract from the online catalog SAC-5P- 1,5-PUR/M12FS SH Order No.: 1682935 Sensor/Actuator cable, 5-position, PUR, halogen-free, Black-gray RAL 7021, shielded, Free conductor end M12, on Socket, straight

More information

C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR C400-UMUM-100 Product Classification Brand Product Series Product Type CNT Jumper with interface types UHF Male and UHF Male, 30.48 m CNT Braided cable assembly General Specifications Body Style, Connector

More information

CUSTOM DESIGN COAXIAL CABLES BY SICAB

CUSTOM DESIGN COAXIAL CABLES BY SICAB CUSTOM DESIGN COAXIAL CABLES BY SICAB. COAX RG 58 C/U Application: Coaxial Cable 50 Ohm For indoor installation as well as in industrial areas in conduits and cable ducts, for transmission of high frequency

More information

SAC-3P- 5,0-PUR/M12FR SH

SAC-3P- 5,0-PUR/M12FR SH Extract from the online catalog SAC-3P- 5,0-PUR/M12FR SH Order No.: 1682838 Sensor/Actuator cable, 3-position, PUR, halogen-free, Black-gray RAL 7021, shielded, Free conductor end, on Socket, angled M12,

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data RFP Specification #17-11125-C, Exhibit 2 Programmable Light Poles for BART Plaza ENGLISH MEASUREMENT VERSION 1502SB Multi-Conductor - Multimedia Control Cable For more Information please call 1-800-Belden1

More information

Copyright June Nexans

Copyright June Nexans Nexans is the worldwide leader in the cable industry, with an industrial presence in 29 countries and commercial activities in 65 countries. Nexans brings an extensive range of advanced copper and optical

More information

MULTIMEDIA & DATA TRANSMISSION

MULTIMEDIA & DATA TRANSMISSION NEXANS, every c a b l e t h a t m a k e s a t r a i n r o l l Whoever you are, rolling stock OEM, subsystem supplier or operator, Nexans provides everything from energy & telecom cable to integrated cabling

More information

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3 Overview Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3 Example drawing (see the chapter belonging to the cable for details) (see the chapter belonging

More information

Four Cat 5e 24 AW G Bonded-Pairs solid bare copper conductors, polyolefin insulation, PVC jacket.

Four Cat 5e 24 AW G Bonded-Pairs solid bare copper conductors, polyolefin insulation, PVC jacket. Part Number: 7923A Cat 5e MSHA DataTuff, (4 pr) 24 AW G Solid BC, PO/PVC, EtherNet/IP, CMR, CMX-Outdoor Product Description Four Cat 5e 24 AW G Bonded-Pairs solid bare copper conductors, polyolefin insulation,

More information

Test Report based on DIN EN ISO/IEC 17025: 2005

Test Report based on DIN EN ISO/IEC 17025: 2005 Test Report based on DIN EN ISO/IEC 1725: 25 GHMT Type Approval 2 Connector Permanent Link, Copper, Class EA according ISO/IEC 1181-1 Ed.1. Document-no: P582a-18-E This Test Report with the measurements

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61935-1 Edition 3.0 2009-07 Specification for the testing of balanced and coaxial information technology cabling Part 1: Installed balanced cabling as specified in ISO/IEC 11801

More information

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø Automated Stacking Cranes (ASC) Ship To Shore Container Cranes (STS) Rubber Tyre Gantry (RTG)

More information

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Train-to-ground communication

Train-to-ground communication Train-to-ground communication Railway antennas Edition 2014 Bridging our technologies Your partner for integrated solutions HUBER+SUHNER is a leading international manufacturer and supplier of components

More information

ECOFLEX 10 Characteristics Diameter 10,2 mm. ECOFLEX 15 Characteristics Diameter 14,6 mm. AIRCOM PLUS Characteristics Diameter 10,3 mm

ECOFLEX 10 Characteristics Diameter 10,2 mm. ECOFLEX 15 Characteristics Diameter 14,6 mm. AIRCOM PLUS Characteristics Diameter 10,3 mm AIRCOM PLUS Characteristics Diameter 10,3 mm Attenuation @ 1 GHz/100m 13,4 db Attenuation @ 1 GHz/100ft 4,08 db 10 GHz ECOFLEX 10 Characteristics Diameter 10,2 mm Attenuation @ 1 GHz/100m 14,2 db Attenuation

More information

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information GORN Central Loose Tube Cables Outdoor A-DQ(ZN)BY Improved Rodent Protection, 000N Permanent Load 05--0 v6.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4 6.5/5-OM GORN0

More information