1 technical bulletin Data communication technology 12/2015 UTP vs STP Shielded data cables make the grade Unshielded data cables reach the limits of their performance Business Unit Datacom LEONI Kerpen GmbH Zweifaller Strasse Stolberg Germany Telefon +49(0) Telefax +49 (0) Author: Strategic market development and standardisation We reserve the right to make technical modification LEONI Kerpen GmbH LEONI technical bulletin 12/2015 1

2 Topics dealt with in this bulletin: Types What about the shield? Types Transmission characteristics Electromagnetic compatibility a) MICE concept b) Performance comparison c) Separation distances Thermal behavior Fire behavior Equipotential bonding, earthing, shielding Conclusions There is a wide range of different types of data cables. They can be classified according to number and position of the shields within the cable structure. Thus, U/UTP data cables have no shield whatsoever. In contrast, S/FTP data cables have a pair shield made of aluminum foil and an overall shield made of tin-plated copper braid. Between these two types, there are other variants that differ in the type of shielding used. The following nomenclature illustrates the most common types. Cable types xx/x x x Overall shielding F Braided shielding S Braiding and foil shielding SF What about the shield? Individual shielding Unshielded Symmetrical element U F P Shielded vs. unshielded data cables The question as to whether shielded or unshielded data cables should be used is as old as data cables themselves. There are justified arguments for and against on both sides which constantly rekindle the long-standing controversy. There is no doubt whatsoever that the unshielded technology now so widespread worldwide meets all requirements when data rates of up to 1 Gbit/s are to be transmitted. S/FTP (PiMF with overall shielding) F/FTP U/FTP Braided shielding So why do you need a shield? It is equally true that shielded cablings offer the best protection against irradiation and radiant emittance, and this is becoming more and more critical in view of the constantly increasing transmission frequencies and the rising degree of electromagnetic contamination. So do Category 8 cables with a bandwidth of 2 GHz provide the answer to the crucial question: What about the shield? SF/UTP F/UTP U/UTP Braiding and foil shielding Figure 1: Construction Data cables over cross element Which cable design is ultimately used depends on the transmission performance required, the electromagnetic compatibility (EMC), the installation conditions, the thermal behavior, the fire behavior and the expected service life. Regional as well as historically conditioned conventions and the inertia of the installed basis also frequently affect the choice of medium. 2 LEONI technical bulletin 12/2015 LEONI technical bulletin 12/2015 3

3 Transmission characteristics Electromagnetic compatibility The capacity of data cables is defined by a set of low-frequency and high-frequency transmission characteristics which, taken together, lead to a maximum transmission frequency / bandwidth. For greater clarity, data cables are divided into Categories 3 to 8 with regard to their transmission characteristics. The correlating cabling system classes C to F A / I/II also allow a correlation to be made with the transmission rate supported (usually an Ethernet protocol). The following table shows the currently existing cable categories in connection with the typical cable design, the maximum transmission frequency and the maximum transmission rate. Unshielded data cables: The table shows that unshielded data cables can only be used up to a maximum of Category 6 A (500 MHz). The reason for this is that the so-called alien crosstalk, i.e. the mutual influencing of adjacent data cables, disturbs data transmission inadmissibly with rising frequency. Electromagnetic compatibility (EMC) describes the ability of electrotechnical devices to work satisfactorily without disturbing other equipment or being disturbed themselves. Fundamentally, the operation of electric or electronic devices should not interfere with the function of other radio and telecommunication systems. This is mainly achieved because the transient emissions of an electrotechnical device are limited on the one hand and the device must have a minimum immunity to interference on the other. a) MICE concept Environmental class The relevant cabling standards ISO/IEC and EN classify the electromagnetic load or contamination of a defined environment in terms of the so-called MICE concept. Parameter/ Level Mechanical Ingress 1 M 1 I 1 2 M 2 I 2 3 M 3 I 3 Climatic C 1 C 2 C 3 Electromagnetic E 1 E 2 E 3 Figure 3: MICE-Conzept relevant ISO/IEC and EN Shielded data cables cover the entire bandwidth up to Category 8.2 (2 GHz). The requirements with regard to alien crosstalk are met by design here. Here there are 3 electromagnetic classes E1, E2 and E3 whose demands rise in step with the index. A simple rule of thumb: The higher the category, the higher the transmission frequency and the bandwidth, i.e. the higher the performance of the data cable. Category Class Max. Frequency Typical Design Transmission rate Ethernet 3 C 16 MHZ U/UTP, F/UTP, SF/UTP up to 10 Mbit/s 5 old "D" 100 MHZ U/UTP, F/UTP, SF/UTP up to 10 Mbit/s 5E D 100 MHZ U/UTP, F/UTP, SF/UTP up to 1 Gbit/s, 2 Gbit/s *(in consulting) 6 E 250 MHZ U/UTP, F/UTP, U/FTP up to 1 Gbit/s, 5 Gbit/s *(in consulting) 6 A E A 500 MHZ U/UTP, F/UTP, U/FTP. F/FTP up to 10 Gbit/s 7 F 600 MHZ S/FTP, F/FTP >10 Gbit/s, hight reserves 7 A F A 1 GHZ S/FTP up to 25 Gbit/s, hight reserves 8.1 I (30 m) 2 GHZ F/UTP up to 40 Gbit/s not backwards compatible to Cat. 7 and 7 A 8.2 II (30 m) 2 GHZ S/FTP up to 40 Gbit/s, very hight reserves * Shielded performance fulfilled as design Figure 2: Category & class, typical design & transmission frequency Electromagnetic E1 E2 E3 Operating range Office Data center Industrial Electrostatic discharge - Contact (0,667 µc) 4 kv 4 kv 4 kv Electrostatic discharge - Air (0,667 µc) 8 kv 8 kv 8 kv Radiated radio frequency, amplitude modulated (RF - Am) 3 V/m at ( ) Mz 3 V/m at ( ) Mz 10 V/m at ( ) Mz 3 V/m at ( ) Mz 3 V/m at ( ) Mz 3 V/m at ( ) Mz 1 V/m at ( ) Mz 1 V/m at ( ) Mz 1 V/m at ( ) Mz Conducted radio frequency (RF) 3 V at 150 khz - 80 MHz 3 V at 150 khz - 80 MHz 10 V at 150 khz - 80 MHz Electrical fast transient /Burst (EFT/B) AC mains power including the protective earth Electrical fast transient / Burst (EFT/B) I/O (signal/ data/control) Surge (transient ground potential difference) - signal, line to earth 1000 V 1000 V 2000 V 500 V 500 V 1000 V 500 V 1000 V 1000 V Magnetic (50/60 Hz) 1 A/m 3 A/m 30 A/m Magnetic (60 Hz to Hz) ffs ffs ffs Figure 4: Demand MICE-Class E 1, E 2, E 3 Class E1 is usually required in the office field, whereas E2 and E3 are mainly encountered in the industrial environment. This explains why shielded data cables are often obligatory there. 4 LEONI technical bulletin 12/2015 LEONI technical bulletin 12/2015 5

4 b) Performance comparison Minimum seperation S A GHMT study comparing the performance of shielded and unshielded cabling systems on location assessed the transient emissions and immunity to interference for 1 Gbit/s and 10 Gbit/s applications. The final ranking underlines the technical superiority of shielded systems in terms of their electromagnetic compatibility. Parameter System 01 U/UTP System 02 U/UTP System 03 F/UTP System 04 S/FTP System 05 S/FTP Radiated radio-frequency disturbance field strength test DIN EN Segration Classification Separation without electromagnetic barrier Containment applied to information technology or mains power cabeling S Open metallic containment Perforated metallic containment Figure. 6: Minimum separation distances as a function of the installation ducts used and the separation class excerpt from EN ) Solid metallic containment d 10 mm 8 mm 5 mm 0 mm c 50 mm 38 mm 25 mm 0 mm b 100 mm 75 mm 50 mm 0 mm a 300 mm 225 mm 150 mm 0 mm Testing immunity to radio-frequency electromagnetic fields DIN EN Electrical fast transient/burst immunity test DIN EN Table for minimum separation distances Test relating to the immunity to conducted disturbances, induced by radio-frequency fields DIN EN A correction factor resulting from the number of electric circuits installed must now be added to the minimum separation distances determined. The minimum separation distances can increase or decrease as a function of the electric circuits installed. Power-frequency magnetic field immunity test DIN EN Electrostatic discharge immunity test DIN EN Ranking Figure. 5: Electromagnetic compatibility of shielded and unshielded systems in comparison (excerpt from GHMT study) c) Separation distances Incidentally, the degree of electromagnetic compatibility also leads to normative specifications for the minimum separation distances of data cables and energy cables installed in a jointly used installation duct. Separation class d can be used for data cables with a coupling attenuation of at least 80 db, i.e. for all data cables according to EN of Category 7 and higher. The separation class d allows the shortest distance between the parallel data and energy cable routes. This has a positive effect on the space requirements. Electrical circuit type Quantity of circuits Power cabeling factor P 1 to 3 0,2 4 to 6 0,4 7 to 9 0,6 10 to 12 0,8 20 A, 230 V, single phase 13 to 15 1,0 16 to to to to 75 5 >75 6 Figure 7: Correction factors for power supply cables (excerpt from EN ) Separation class c must be used for data cables with a coupling attenuation of at least 55 db. This usually concerns shielded cables of Category 5 and Category 6. Separation class b must be used for data cables with a coupling attenuation of at least 40 db. This usually concerns unshielded cables of Category 5 and Category 6. 6 LEONI technical bulletin 12/2015 LEONI technical bulletin 12/2015 7

5 Thermal behavior Fire behavior In conjunction with the accumulation of cables in the installation duct, the constant increase in the power transmitted via Power over Ethernet (PoE) (100W in future) can cause noticeable temperature increases in the data cables which can become inadmissible in extreme cases. The heating up of cables depends on the following factors: Power load (as a function of the PoE standard used) Cable design (in particular conductor cross-section) Number of cable bundles in the installation duct Installation environment (heat dissipation) Environmental temperature Data cables permanently installed in buildings fall under the Construction Products Regulation EU No. 305/2011, which has now come into full force for all member states of the EU. 7 different European fire classes (Aca, B1ca, B2ca, Cca, Dca, Eca and Fca) as well as 3 additional classifications (smoke development, acidity and burning drops) were designated in this connection. A is the highest fire class and F is the lowest. Ranking A ca B1 ca B2 ca C ca D ca E F Standard EN ISO 1716 FIPEC Sce n2 FIPEC Sce n2 FIPEC Sce n2 FIPEC Sce n2 EN H (mm) FS (m) 1,75 1,5 2,0 THR (MJ) The correct cable design makes a crucial contribution to minimizing the heating up of the cable. EN HRR (kw) FIGRA (W/s) Rule of thumb: The higher the category, the lower the heating up additional classification EN smoke emission s1a, s1b, s2, s3 s1a, s1b, s2,s3 s1a, s1b, s2, s3 s1a, s1b, s2, s3 nein nein EN acid liberates a1, a2, a3 a1, a2, a3 a1, a2, a3 a1, a2, a3 nein nein This is because the conductor cross-section rises in step with the increasing category; the DC resistance drops and so does the heat dissipated. EN burning drops d0, d1, d2 d0, d1, d2 d0, d1, d2 d0, d1, d2 nein nein Figure 9: Requirements of European fire classes In the example from ISO/IEC TR shown here, shielded data cables of Category 7 A show 36 % less heating up compared with unshielded data cables of Category 5. Considered according to economic and technical aspects, the use of Class B2ca will probably be required for very high safety requirements, and Cca for high safety requirements. Size of cable bundle (Quantity cable) Temperature rise C Category 5 Category 6 Category 6 A Category 7 Category 7 A Special designs with very high safety requirements (for hospitals, rest homes and kindergartens) and in escape routes: use of cables of Class B2ca In buildings with high security requirements (administrative and office buildings, multi-storey buildings, hotels): use of cables of Class Cca Figure 8: Heating up of cables as a function of the cable category (from ISO/IEC TR 29125) -36% Proposal as to the European classes to be used for fire protection cables Euroclasses Additional classes Security requirements Flame progagation / heat development Smoke production / density Acidity development / particles Flaming droplets / particles in a bulding A ca very high B1 ca very high B2 ca s1 a1 d1 very high C ca s1 a1 d1 high D ca s2 a1 d2 medium E ca low none F ca Figure 10: Recommendation for fire classes as a function of the fire risk In a shielded data cable, the cable functions as a protective shield in case of fire. The result is a significantly better fire behavior than with unshielded versions 8 LEONI technical bulletin 12/2015 LEONI technical bulletin 12/2015 9

6 Equipotential bonding, earthing, shielding System security with regard to transmission technology and the protection of persons... is achieved by means of the shielding of the data cabling and via the equipotential bonding system within the building. Here the power supply has to be realized according to the TN-S system (separate neutral and protective conductor) so that no leakage currents can flow across the data cable shields. The cable shield must have contact with the connector on both sides and be continuous in order to form a Faraday cage and thus achieve a good EMC. All-round contacting (i.e. 360 ) is the most effective solution. Health and safety requirements demand at least one one-sided connection of the shield to the equipotential bonding system of the building (for example on the patch panel). All equipotential bonding conductors run via the shortest possible distance to a common equipotential bonding rail connected with the central earthing point of the building. Equipotential bonding therefore ensures that a potential difference cannot arise between devices and that dangerous contact voltages or compensation currents do not flow through the shielding. The earthing and equipotential bonding system is realized according to ISO/IEC internationally and according to EN and EN and 2 in Europe. Incidentally, the earthing of data cable outlets is not obligatory, even when they have housings made of metal or other conductive materials. Conclusions As described above, even though unshielded cable technology is still predominant worldwide, there is a clear trend towards using shielded. The fact that cables of Category 8 (2 GHz) can only be realized with a shield demonstrates the technical limits of unshielded cables. The Technical Bulletin also demonstrates many more advantages of shielded cables which allow real customer benefits, thus providing numerous arguments for using them. In the comparison of the transmission characteristics, the electromagnetic compatibility, the thermal behavior and the fire behavior, the shield is the downright winner. 10 LEONI technical bulletin 12/2015

Independent 3rd Party Test Study for 10GBE. New insights for end users and consultants

Independent 3rd Party Test Study for 10GBE. New insights for end users and consultants Independent 3rd Party Test Study for 10GBE New insights for end users and consultants Content Why & Who & What & How? Qualification Testing Study Results Study Conclusions Unmasking of UTP fairytales Where

More information

High precision measurement system for current and voltage IHC-A/B-RM01/03

High precision measurement system for current and voltage IHC-A/B-RM01/03 Measurement Offset-free and low-noise 16 bit data acquisition system ISA-ASIC Internal sample rate 3,500 Hz Communication Standard RS232- or RS485 interface Advantages Direct measurement on the bus bar

More information

Comparison of vario. ous cables & channels

Comparison of vario. ous cables & channels Noise Immunity Performance Analysis of Screened Cab bling Systems Comparison of vario ous cables & channels Martin Rossbach, Nexans Cabling Solutions Victoria, BC, Canada May 16, 2013 Overview Definition

More information

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Cable Solutions for Servo and Variable Frequency Drives (VFD) Cable Solutions for Servo and Variable Frequency Drives (VFD) Electric drive systems with continuous torque and speed control are widespread today. They allow an optimal adjustment of the drive with respect

More information

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor. Introduction to EMC Schurter has over 75 years experience in the electronics and electrical industries, developing and manufacturing components that ensure a clean and safe supply of power. Schurter provides

More information

Category 6 A F/FTP Euroclass C ca Cables

Category 6 A F/FTP Euroclass C ca Cables Category 6 A F/FTP Euroclass C ca s Datasheet: GD103266v2 APPLICATION The Brand-Rex AC6F/FTP C ca cables are compliant with the European Construction Products Regulation, achieving Euroclass level C ca

More information

9 Specifications. Specifications NOMINAL CHARACTERISTICS

9 Specifications. Specifications NOMINAL CHARACTERISTICS 9 Specifications Specifications NOMINAL CHARACTERISTICS WARRANTED CHARACTERISTICS Nominal characteristics describe parameters and attributes that are guaranteed by design, but do not have associated tolerances.

More information

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation

More information

2620 Modular Measurement and Control System

2620 Modular Measurement and Control System European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2620 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic

More information

This specification describes termination procedures of AMP Netconnect Cat.6 Compact Patch Panel 0.5U:

This specification describes termination procedures of AMP Netconnect Cat.6 Compact Patch Panel 0.5U: Application 4-9300 Specification Nov 06 Rev.C AMP Netconnect* Cat.6 Compact Patch Panel 0.5U, 4 Ports. SCOPE This specification describes termination procedures of AMP Netconnect Cat.6 Compact Patch Panel

More information

ACR (Attenuation to Crosstalk Ratio) ACR-F. Alien Crosstalk. Attenuation (signal attenuation, conductor attenuation)

ACR (Attenuation to Crosstalk Ratio) ACR-F. Alien Crosstalk. Attenuation (signal attenuation, conductor attenuation) ACR (Attenuation to Crosstalk Ratio) The distance between the wanted signal and the interfering signal (ACR) is an important factor for the transmission quality. To ensure a faultless transmission, the

More information

Data sheet Patch cord Cat.6 A AWG m yellow

Data sheet Patch cord Cat.6 A AWG m yellow Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification especially suitable for shielded and unshielded class E A systems fully shielded Cat.6 A patch

More information

EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN

EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN OVERVIEW Purpose: Examine the common-mode and differential RF ingress levels of 4-pair UTP, F/UTP, and F/FTP cables at an (RJ45) MDI port

More information

EMI AND BEL MAGNETIC ICM

EMI AND BEL MAGNETIC ICM EMI AND BEL MAGNETIC ICM ABSTRACT Electromagnetic interference (EMI) in a local area network (LAN) system is a common problem that every LAN system designer faces, and it is a growing problem because the

More information

C series Product brief

C series Product brief Product brief Key applications Landlord sub-metering Object metering Meter performance Direct connected up to 0 ctive energy Low power consumption larm function Pulse output Installation Small size - 1

More information

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog NOVOHALL Rotary Sensor non-contacting Series RSC2800 analog The RSC 2800 sensor utilizes a contactless magnetic measurement technology to determine the measured angle. Unlike conventional Hall sensors,

More information

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation

More information

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University Overview of EMC Regulations and Testing Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University What is EMC Electro-Magnetic Compatibility ( 電磁相容 ) EMC EMI (Interference) Conducted

More information

Category 6 UTP EuroClass C ca Cables

Category 6 UTP EuroClass C ca Cables Category 6 UTP EuroClass C ca Cables Datasheet: GD103704v1 APPLICATION Brand-Rex Cat6Plus C6U cables exceed the Category 6 performance standards. They are rated to 250MHz and are suitable for use in all

More information

Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN :2007 (IEC :2007)

Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN :2007 (IEC :2007) Compressor set Equipment Under Test (EUT) Type 028 Type 047 Type 052 Type 085 Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN 60601-1-2:2007 (IEC 60601-1-2:2007) 2017 PARI

More information

One-day Conference 18 March Power Supply, EMC and Signalling, in Railway Systems

One-day Conference 18 March Power Supply, EMC and Signalling, in Railway Systems One-day Conference 18 March 2017 Power Supply, EMC and Signalling, in Railway Systems EMC Management and Related Technical Aspects in Railway Systems By Dr Peter S W LEUNG http://www.ee.cityu.edu.hk/~pswleung/

More information

BIODEX MULTI- JOINT SYSTEM

BIODEX MULTI- JOINT SYSTEM BIODEX MULTI- JOINT SYSTEM CONFORMANCE TO STANDARDS 850-000, 840-000, 852-000 FN: 18-139 5/18 Contact information Manufactured by: Biodex Medical Systems, Inc. 20 Ramsey Road, Shirley, New York, 11967-4704

More information

NETWORK CONNECTIVITY SYSTEMS

NETWORK CONNECTIVITY SYSTEMS NETWORK CONNECTIVITY SYSTEMS Installation Cable KS-STP Category 7 Installation Cable Certificates 10GBaseT FTP Category 6 Installation Cable UTP Category 6 Installation Cable UTP Category 5E Installation

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61156-1 Third edition 2007-06 Multicore and symmetrical pair/quad cables for digital communications Part 1: Generic specification Commission Electrotechnique Internationale International

More information

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

Modem 9600 baud 500FSD11 EDS500 series - FSK modems Data sheet Modem 9600 baud 500FSD11 EDS500 series - FSK modems Voice frequency telegraphy device (VFT) Transparent up to 9600 baud Can be connected to 23WT24 DIN rail mounted 24...60 V DC supply voltage

More information

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi TS ii ortable Tourniquet System Guidance and manufacturer s declaration electromagnetic emissions The TS ii ortable Tourniquet

More information

EMC filters. Mounting instructions. Date: January 2006

EMC filters. Mounting instructions. Date: January 2006 Date: January 2006 EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet and the information contained therein without EPCOS prior express consent is prohibited. EMC cannot be assured

More information

EDBEMV!PZi. Ä!PZiä. Electromagnetic compatibility. Global Drive Basic information on controller applications in plants and machinery

EDBEMV!PZi. Ä!PZiä. Electromagnetic compatibility. Global Drive Basic information on controller applications in plants and machinery EDBEMV!PZi Ä!PZiä L Electromagnetic compatibility Global Drive Basic information on controller applications in plants and machinery 2003 Lenze Drive Systems GmbH Without written approval of Lenze Drive

More information

Power Quality. Case Study. Conrad Bottu Laborelec January 2008

Power Quality. Case Study. Conrad Bottu Laborelec January 2008 Case Study Electromagnetic compatibility (EMC) study Breakdown of low voltage electronic equipment in a 25 kv substation Conrad Bottu Laborelec January 2008 Power Quality Power Quality 1 Introduction Description

More information

Test Report based on DIN EN ISO/IEC 17025: 2005

Test Report based on DIN EN ISO/IEC 17025: 2005 Test Report based on DIN EN ISO/IEC 1725: 25 GHMT Type Approval 2 Connector Permanent Link, Copper, Class EA according ISO/IEC 1181-1 Ed.1. Document-no: P582a-18-E This Test Report with the measurements

More information

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description Description Cat 8 Filler Cat.8.2 S/FTP Horizontal cables (x6) Fan-Out Cables Cat 8 STP Keystones TRUNK CABLE SECTION VIEW Assembly Isometric Front View RiT s Copper Install & Go System provides a pre-terminated

More information

Technical information Release 07/2010. Cable management systems for improvement of EMC

Technical information Release 07/2010. Cable management systems for improvement of EMC Technical information Release 07/2010 Cable management systems for improvement of EMC Definition of electromagnetic compatibility (EMC) In recent years, the use of electronic circuits has increased continually.

More information

EMC in the railway environment Hans Bängtsson

EMC in the railway environment Hans Bängtsson EMC in the railway environment 2018-05-17 Hans Bängtsson Aspects of EMC in the railway environment LEGAL radio-, TV- and tele communications must not be interfered SAFETY The railway signaling ( red and

More information

1) The diagrams in the section Assembly notes were provided by Rittal GmbH Co. KG, Herborn and by Invensys Systems GmbH EUROTHERM, Limburg/ Lahn.

1) The diagrams in the section Assembly notes were provided by Rittal GmbH Co. KG, Herborn and by Invensys Systems GmbH EUROTHERM, Limburg/ Lahn. EMC cannot be achieved by the use of EMC filters alone. It must be considered as an integrated system and requires careful planning and preparations. Measures such as shielded motor leads, grounding and

More information

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2 Page 1/7 Illustrations Principle diagram See enlarged drawings at the end of document Product specification 10 GBit installation cable, simplex installation cable Cat.7A AWG 22 S/FTP with wires shielded

More information

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi Features Special relay for alternating loads, for applications with pumps, compressors, air conditioning or refrigeration units 2 independent NO output, 12 A 4 functions 2 independent control signals,

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

Cabling systems for LAN Office, LAN Home, LAN Industry, Access Networks, MAN, WAN and SAN. 10 GBit. ELine, MegaLine, FLine, GigaLine

Cabling systems for LAN Office, LAN Home, LAN Industry, Access Networks, MAN, WAN and SAN. 10 GBit. ELine, MegaLine, FLine, GigaLine COMPETENCE IN CABLE TECHNOLOGY ready for 0 GBit E t h e r n e t ELine, MegaLine, FLine, GigaLine Solutions@KERPEN Cabling systems for LAN Office, LAN Home, LAN Industry, Access Networks, MAN, WAN and SAN

More information

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft Page 1/6 MC GC0 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft 18427034141 Illustrations Principle diagram Product specification 10 GBit installation cable, simplex installation cable Cat.7 AWG 23 S/FTP with wires

More information

INTERNATIONAL TELECOMMUNICATION UNION SERIES K: PROTECTION AGAINST INTERFERENCE

INTERNATIONAL TELECOMMUNICATION UNION SERIES K: PROTECTION AGAINST INTERFERENCE INTERNATIONAL TELECOMMUNICATION UNION ITU-T K.42 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (05/98) SERIES K: PROTECTION AGAINST INTERFERENCE Preparation of emission and immunity requirements for

More information

Test Report based on DIN EN ISO/IEC 17025:2005

Test Report based on DIN EN ISO/IEC 17025:2005 Test Report based on DIN EN ISO/IEC 1725:25 GHMT Type Approval 2 Connector Permanent Link, Copper, Class E according ISO/IEC 1181-1 Ed.1. 217-11 Document-no: P4945b-18-E This Test Report with the measurements

More information

Power supply CP-E 24/20.0

Power supply CP-E 24/20.0 2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output

More information

SERIES K: PROTECTION AGAINST INTERFERENCE

SERIES K: PROTECTION AGAINST INTERFERENCE International Telecommunication Union ITU-T K.49 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (12/2005) SERIES K: PROTECTION AGAINST INTERFERENCE Test requirements and performance criteria for voice

More information

EMC Test Report. Report Number: M030826

EMC Test Report. Report Number: M030826 Page 1 of 36 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EMC Test Report Report

More information

Harmonizing the ANSI-C12.1(2008) EMC Tests. Harmonizing the ANSI-C12.1(2008) EMC Tests

Harmonizing the ANSI-C12.1(2008) EMC Tests. Harmonizing the ANSI-C12.1(2008) EMC Tests Harmonizing the ANSI-C12.1(2008) EMC Tests Subcommittee 1 (Emissions) Subcommittee 5 (Immunity) Joint Task Force on C12.1 June 17, 2013 1 The Accredited Standards Committee C63 presents Harmonizing the

More information

UC DATA CABLES - CAT 5,6, 7 & 8

UC DATA CABLES - CAT 5,6, 7 & 8 UC DATA CABLES - CAT 5,6, 7 & 8 Fast and reliable copper cables for network solutions Connecting communities with communications PRYSMIAN GROUP A MARKET LEADER IN THE TELECOM INDUSTRY As the worldwide

More information

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

Coupling attenuation and EMC considerations Draft 1.2 Comments #363 and #364

Coupling attenuation and EMC considerations Draft 1.2 Comments #363 and #364 Coupling attenuation and EMC considerations Draft 1.2 Comments #363 and #364 Dieter Schicketanz Reutlingen University Page 1 Due to measurement implications CISPR divided the frequency range in: Below

More information

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact Data sheet Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact The CT-EBE is an electronic time relay with the function flasher starting with OFF. It is from the CT-E range. The CT-E

More information

Understanding Design, Installation, and Testing Methods That Promote Substation IED Resiliency for High-Altitude Electromagnetic Pulse Events

Understanding Design, Installation, and Testing Methods That Promote Substation IED Resiliency for High-Altitude Electromagnetic Pulse Events Understanding Design, Installation, and Testing Methods That Promote Substation IED Resiliency for High-Altitude Electromagnetic Pulse Events Tim Minteer, Travis Mooney, Sharla Artz, and David E. Whitehead

More information

Overview of the ATLAS Electromagnetic Compatibility Policy

Overview of the ATLAS Electromagnetic Compatibility Policy Overview of the ATLAS Electromagnetic Compatibility Policy G. Blanchot CERN, CH-1211 Geneva 23, Switzerland Georges.Blanchot@cern.ch Abstract The electromagnetic compatibility of ATLAS electronic equipments

More information

EMC Data Sheet CSD100 Model size 4 to 6. Variable Speed AC drive for permanent magnet motors

EMC Data Sheet CSD100 Model size 4 to 6. Variable Speed AC drive for permanent magnet motors EMC Data Sheet CSD100 Model size 4 to 6 Variable Speed AC drive for permanent magnet motors Safety Warnings A Warning contains information which is essential for avoiding a safety hazard. A Caution contains

More information

z48831 / z :1/ 16:1 6 GHz Multiplexer Module

z48831 / z :1/ 16:1 6 GHz Multiplexer Module TECHNICAL SPECIFICATIONS z48831 / z48832 8:1/ 16:1 6 GHz Multiplexer Module 2017 LitePoint, A Teradyne Company. All rights reserved. Port Descriptions Front Panel Label Type Description 1-16 SMA RF1 to

More information

Data sheet Cable connector class F A

Data sheet Cable connector class F A Illustrations Dimensional drawing See enlarged drawings at the end of document Product specification cable connector for field assembly Class F A for 8 wire cables to connect / extend / repair / relocate

More information

Three-phase monitoring relay CM-PVE

Three-phase monitoring relay CM-PVE Data sheet Three-phase monitoring relay CM-PVE The three-phase monitoring relay CM-PVE monitors the phase parameter phase failure as well as over- and undervoltage in three-phase mains. 2CDC 251 006 S0012

More information

SERIES K: PROTECTION AGAINST INTERFERENCE

SERIES K: PROTECTION AGAINST INTERFERENCE International Telecommunication Union ITU-T K.21 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (04/2008) SERIES K: PROTECTION AGAINST INTERFERENCE Resistibility of telecommunication equipment installed

More information

BICSI Standards Update December Stephen Banks RCDD CDCDP

BICSI Standards Update December Stephen Banks RCDD CDCDP BICSI Standards Update December 2009 Stephen Banks RCDD CDCDP Nightlake Limited 22 Highgate Square Birmingham B12 0DU 1 Phone : + 44 (0) 870 765 3301 Fax : + 44 (0) 870 765 3302 Web : www.nightlake.com

More information

Install & Go Cat.8 STP Trunk Cable Assembly Description

Install & Go Cat.8 STP Trunk Cable Assembly Description Description Cat 8 Filler Cat.8.2 S/FTP Horizontal cables (x6) Fan-Out Cables Cat 8 STP Keystones TRUNK CABLE SECTION VIEW Assembly Isometric Front View RiT s Copper Install & Go System provides a pre-terminated

More information

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc. A Comparison Between MIL-STD and Commercial EMC Requirements Part 2 By Vincent W. Greb President, EMC Integrity, Inc. OVERVIEW Compare and contrast military (i.e., MIL-STD) and commercial EMC immunity

More information

POINTAX 6000L2 Point Recorder

POINTAX 6000L2 Point Recorder GOSSEN METRAWATT CAMILLE BAUER Special Features 6 measuring channels Last printed point visible from front Electrically isolated, earth-free measuring channels Process signals ranging from 0/4... 20 ma,

More information

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13 INSTALLATION MANUAL Model: Smart Analyzer Manufacturer: Smart Impulse Power meter with consumption breakdown by use 03/12/13 Table of contents Table of contents... 2 1. Introduction... 3 2. Installation

More information

Power supply CP-D 12/2.1

Power supply CP-D 12/2.1 2CDC 271 025 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 12 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 2.1 A Rated output power

More information

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 48/20.0 Primary switch mode power supply Data sheet Power supply CP-T 48/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

MID energy meter B21 Single-phase energy meter, 65 A

MID energy meter B21 Single-phase energy meter, 65 A MID energy meter B2 Single-phase energy meter, 5 Single-phase energy meter ( + ) Direct connection up to 5 Width, 2 DI modules Tested and approved per MID * and IEC * Regional different requirements apply

More information

MDEX. on customized sensors. Technical information. Torque transducer. CS-T-04-MDEX Special features

MDEX. on customized sensors. Technical information. Torque transducer. CS-T-04-MDEX Special features MDEX Torque transducer CS-T-04-MDEX Special features - Explosion proof acc. to ATEX 95 - Exx II 2 G Ex deq IIC T4 - Nominal (rates) torque of 100kNm, 130kNm and 150kNm - HBM Accuracy Class 0,1 - Digital

More information

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O DATASHEET NI REM-11120 Temperature Input Module for Remote I/O 4 thermocouple channels with input range of ±100 mv 1 voltage input channel with range of ±5V 24-bit resolution Optional external CJC or additional

More information

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft Page 1/7 Illustrations Principle diagram Product specification 10 GBit installation cable, duplex installation cable Cat.7A AWG 22 S/FTP with wires shielded in pairs 2x4 pairs (PiMF) pair shield: plastic

More information

OPSJ1900 J1900 Open Pluggable Specification Products

OPSJ1900 J1900 Open Pluggable Specification Products J1900 Open Pluggable Specification Products Extensive range of computational power and letting you choose between diffrent operating systems, Finlux always offers you the most suitable choice that will

More information

IEEE RTPGE Automotive Datalinks over Twisted Quad Cabling

IEEE RTPGE Automotive Datalinks over Twisted Quad Cabling Automotive Datalinks over Twisted Quad Cabling T. Müller, G. Armbrecht, S. Kunz Rosenberger Hochfrequenztechnik GmbH & Co. KG Outline Automotive Datalinks over Twisted Quad Cabling Twisted Quad fundamentals

More information

Powered Traction Unit OPERATION MANUAL

Powered Traction Unit OPERATION MANUAL Powered Traction Unit OPERATION MANUAL CONTENTS Symbols Safety precautions Symbol for CAUTION Symbol for CONSULT INSTRUCTIONS FOR USE Symbol for SERIAL NUMBER Symbol for CATALOGUE NUMBER Symbol for AUTHORISED

More information

SERIES K: PROTECTION AGAINST INTERFERENCE

SERIES K: PROTECTION AGAINST INTERFERENCE International Telecommunication Union ITU-T K.21 TELECOMMUNICTION STNDRDIZTION SECTOR OF ITU (11/2011) SERIES K: PROTECTION GINST INTERFERENCE Resistibility of telecommunication equipment installed in

More information

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14 3-349-813-3 1/9.14 Insulation measurement per EN 61557-2/VDE 413, part 2 Test voltages: 5 V, 1 V, 25 V, 5 V and 1 V Analog display of measured values and limit values Intelligent filter precise and measurement-dependent

More information

EMC Data Sheet Unidrive-M Model size 3. Variable Speed AC drive for induction and permanent magnet motors

EMC Data Sheet Unidrive-M Model size 3. Variable Speed AC drive for induction and permanent magnet motors EMC Data Sheet Unidrive-M Model size 3 Variable Speed AC drive for induction and permanent magnet motors Safety Warnings A Warning contains information which is essential for avoiding a safety hazard.

More information

NOVOHALL Rotary Sensor touchless technology transmissive. Series RFC4800 analog

NOVOHALL Rotary Sensor touchless technology transmissive. Series RFC4800 analog NOVOHALL Rotary Sensor touchless technology transmissive Series RFC4800 analog The RFC 4800 utilizes a separate magnet or magnetic position marker, attached to the rotating shaft to be measured. The orientation

More information

SWT 3000 Teleprotection technical data siemens.com

SWT 3000 Teleprotection technical data siemens.com Power network telecommunication SWT 3000 Teleprotection technical data siemens.com Sustainable success for high-voltage power networks The SWT 3000 Teleprotection system has been the first choice for reliable

More information

Power Quality Issues from an EMC Point of View

Power Quality Issues from an EMC Point of View Power Quality Issues from an EMC Point of View Brian Jones BSc (Hons) C Eng MIEE MIEEE Overview What is EMC? How does it apply to power quality? The effects of equipment on power quality The effects of

More information

ECE 528 Understanding Power Quality

ECE 528 Understanding Power Quality ECE 528 Understanding Power Quality http://www.ece.uidaho.edu/ee/power/ece528/ Paul Ortmann portmann@uidaho.edu 208-733-7972 (voice) Lecture 41 1 Today Wiring for communications Decibels Coupling Avoiding

More information

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental NOVOHALL Rotary Sensor non-contacting Series RSC2800 digital SSI, SPI, Incremental The RSC 2800 sensor utilizes a contactless magnetic measurement technology to determine the measured angle. Unlike conventional

More information

SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT International Telecommunication Union ITU-T L.1005 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (02/2014) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE

More information

Standardisation and Immunity Tests regarding IEMI

Standardisation and Immunity Tests regarding IEMI Standardisation and Immunity Tests regarding IEMI Véronique Beauvois ULG ERTMS: European Railway Traffic Management System ERTMS = Unique signalling standards throughout Europe M O D E M GSM-R Data and

More information

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS EMC-E20130903E EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS Prepared for : MPP SOLAR INC Address : 4F, NO. 50-1, SECTION 1, HSIN-SHENG S. RD. TAIPEI, TAIWAN Prepared by

More information

Bulk Current Injection instead of Radiated immunity testing, in the range from 1 MHz upto 1 GHz: Measuring results

Bulk Current Injection instead of Radiated immunity testing, in the range from 1 MHz upto 1 GHz: Measuring results Immunity Testing: radiated immunity 41 Bulk Current Injection instead of Radiated immunity testing, in the range from 1 MHz upto 1 GHz: Measuring results Immunity Testing: radiated immunity 42 Bulk Current

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61000-2-13 First edition 2005-03 BASIC EMC PUBLICATION Electromagnetic compatibility (EMC) Part 2-13: Environment High-power electromagnetic (HPEM) environments Radiated and

More information

75W Constant Current (700mA) LED Driver

75W Constant Current (700mA) LED Driver 75W Constant Current (700mA) LED Driver IZC070-075A-9267C-SA Product Overview The IZC070-075A-9267C-SA operates from a 90-305 Vac input range. This unit will provide up to 700mA of output current and a

More information

Electromagnetic Compatibility of Power Converters

Electromagnetic Compatibility of Power Converters Published by CERN in the Proceedings of the CAS-CERN Accelerator School: Power Converters, Baden, Switzerland, 7 14 May 2014, edited by R. Bailey, CERN-2015-003 (CERN, Geneva, 2015) Electromagnetic Compatibility

More information

Datasheet. messtechnik gmbh. Torque ranges from 0,5 to 1000 Nm. Features. Extra Features DRBK-A. Torque Transducer DRBK + DRBK-A

Datasheet. messtechnik gmbh. Torque ranges from 0,5 to 1000 Nm. Features. Extra Features DRBK-A. Torque Transducer DRBK + DRBK-A messtechnik gmbh tel. +49 (0)79 72 93 10-0 hagstrasse 10. D-74417 gschwend vertrieb@eth-messtechnik.de Datasheet Torque Transducer DRBK + DRBK- Torque ranges from 0,5 to 1000 Nm Features Very short Broad

More information

Industrial, 2-Pole ZS Type RA2A

Industrial, 2-Pole ZS Type RA2A Solid State Relays Industrial, 2-Pole ZS Type 2-Pole AC Solid State Relay Zero switching For resistive and inductive AC loads Direct copper bonding (DCB) technology LED indication Rated operational current:

More information

SERIES K: PROTECTION AGAINST INTERFERENCE

SERIES K: PROTECTION AGAINST INTERFERENCE I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T K.21 TELECOMMUNICTION STNDRDIZTION SECTOR OF ITU (07/2017) SERIES K: PROTECTION GINST INTERFERENCE Resistibility of telecommunication

More information

Three-phase monitoring relays CM-PFE and CM-PFE.2

Three-phase monitoring relays CM-PFE and CM-PFE.2 Data sheet Three-phase monitoring relays CM-PFE and CM-PFE.2 The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251

More information

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

EMC Seminar Series All about EMC Testing and Measurement Seminar 1 EMC Seminar Series All about EMC Testing and Measurement Seminar 1 Introduction to EMC Conducted Immunity Jeffrey Tsang Organized by : Department of Electronic Engineering 1 Basic Immunity Standards: IEC

More information

Immunity Testing for the CE Mark

Immunity Testing for the CE Mark Immunity Testing for the CE Mark Summary The European Union (EU) currently has 25 member countries with 2 additional countries to be added in 2007. The total population at that time will be nearly a half

More information

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply Data sheet Power supply CP-T 48/5.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Modeling and Practical Suggestions to Improve ESD Immunity Test Repeatability

Modeling and Practical Suggestions to Improve ESD Immunity Test Repeatability 17 th Symposium IMEKO TC, 3 rd Symposium IMEKO TC 19 and 15 th IWDC Workshop Sept. -1, 1, Kosice, Slovakia Modeling and Practical Suggestions to Improve ESD Immunity Test Repeatability. Morando 1, M. Borsero,.

More information

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC Features DIN-Rail Description 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection

More information

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC Features DIN-Rail 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection Parallel

More information

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING Technical leaflet 2 RD.5G.H4.02 Danfoss A/S (IC-MC/mr), 09-2004 Introduction AKS 32 and AKS 33 are pressure transmitters that

More information

Information technology. Generic cabling systems, General requirements

Information technology. Generic cabling systems, General requirements KRAMER WELL CONNECTED WITH KRAMER BCLS-33OR-5 Al-Mylar Conductor CAT6A F/UTP LSZH Cable Drain Wire Kramer s BCLS-33OR is a high performance CAT6A F/UTP cable designed for IT, LAN and Ethernet installations.

More information

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load Features Regulated Converter Description 4mW max. no load power consumption High efficiency up to 76% Isolated output 3kVAC / 1 min SCP, OVP protection Wide operating temperature range: -4 C to +85 C Universal

More information

EC6011-ELECTROMAGNETICINTERFERENCEANDCOMPATIBILITY

EC6011-ELECTROMAGNETICINTERFERENCEANDCOMPATIBILITY EC6011-ELECTROMAGNETICINTERFERENCEANDCOMPATIBILITY UNIT-3 Part A 1. What is an opto-isolator? [N/D-16] An optoisolator (also known as optical coupler,optocoupler and opto-isolator) is a semiconductor device

More information