Filled Solid ALPETH Cable
|
|
- Aileen Chapman
- 5 years ago
- Views:
Transcription
1 I. Exchange Cables Filled Solid ALPETH Cable REA/RUS PE CONDUCTORS: Solid, annealed copper wires, in 2, 24, 22 and 19 AWG. INSULATION: Solid, high-density polyeylene or polypropylene in distinctive colors, conforming to telephone industry standards. PAIRS: Insulated conductors are twisted togeer to form pairs, wi different twist lay lengs to minimize capacitance unbalance and crosstalk. CORE ASSEMBLY: In cables wi pairs or less, e pairs are laid forming a cylindrical shape. For larger cables, units of pairs or superunits of or pairs are assembled to form e final core. The core is filled wi ETPR (80 C) compound. Then covered wi a non-hygroscopic tape wi an overlap. A filling compound is applied over e wrap. All units and superunits are identified wi color coded, non-hygroscopic, non-wicking binders. In order to have a rounder shape and better electrical performance, all units and superunits are divided into and 13 pair sub-units. SHIELD: Corrugated, copolymer coated, 8-mil ick aluminum tape applied longitudinally wi an overlap. The coating reduces e risk of shield corrosion. A flooding compound wi adhesive properties is applied over e shield. JACKET: weight polyeylene. Sequential footage (or meter) markings are printed on e jacket at 2 foot (or 1 m) intervals. Outside plant telephony or underground installation. Meets REA/RUS PE-39 ANSI/ICEA S Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor. Telecordia (Bellcore) equivalent: none ISO-1 Quality Assurance System Packaged on wooden reels wi a ermal wrap applied over e cable. The reels are also lagged for additional protection. Condumex Wire and Cable Street - Grand Prairie, TX 7 - (800)
2 2 AWG AWG AWG AWG Note: Values shown are nominal, subject to manufacturing tolerances. Special lengs are available upon request.
3 I. Exchange Cables Filled Foam Skin ALPETH Cable REA/RUS PE CONDUCTORS: Solid, annealed copper wires, in 2, 24, 22 AND 19 AWG. INSULATION: Expanded polyeylene (Foam Skin) wi an external layer of solid, high-density polyeylene in distinctive colors, conforming to telephone industry standards. PAIRS: Insulated conductors are twisted togeer to form pairs, wi different twist lay lengs to minimize capacitance unbalance and cross-talk. CORE ASSEMBLY: In cables wi pairs or less, e pairs are laid forming a cylindrical shape. For larger cables, units of pairs or superunits of or pairs are assembled to form e final core. The core is filled wi ETPR (80 C) compound. Then covered wi a non-hygroscopic tape wi an overlap. A filling compound is applied over e wrap. All units and superunits are identified wi color coded, non-hygroscopic, non-wicking binders. In order to have a rounder shape and better electrical performance, all units and super-units are divided into and 13 pairs sub-units. SHIELD: Corrugated, copolymer coated, 8-mil ick aluminum tape applied longitudinally wi an overlap. The coating reduces e risk of shield corrosion. A flooding compound wi adhesive properties is applied over e shield. JACKET: weight polyeylene. Sequential footage (or meter) markings are printed on e jacket at 2 foot (or 1 m) intervals. Outside plant telephony or underground installation. Meets REA/RUS PE-89 ANSI/ICEA S Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor. Telecordia (Bellcore) equivalent: AN_A ISO-1 Quality Assurance System Packaged on wooden reels wi a ermal wrap applied over e cable. The reels are also lagged for additional protection. Condumex Wire and Cable Street - Grand Prairie, TX 7 - (800)
4 2 AWG AWG AWG AWG Note: Values shown are nominal, subject to manufacturing tolerances. Special lengs are available upon request.
5 I. Exchange Cables Filled Foam Skin CACSP Cable REA/RUS PE CONDUCTORS: Solid, annealed copper wires, in 2, 24, 22 and 19 AWG. INSULATION: Expanded polyeylene (Foam Skin) wi an external layer of solid, high-density polyeylene in distinctive colors, conforming to telephone industry standards. PAIRS: Insulated conductors are twisted togeer to form pairs, wi different twist lay lengs to minimize capacitance unbalance and cross-talk. CORE ASSEMBLY: In cables wi pairs or less, e pairs are laid forming a cylindrical shape. For larger cables, units of pairs or superunits of or pairs are assembled to form e final core. The core is filled wi ETPR (80 C) compound. Then covered wi a non-hygroscopic tape wi an overlap. Filling compound is also applied over e wrap. All units and superunits are identified wi color coded, non-hygroscopic, non-wicking binders. In order to have a rounder shape and better electrical performance, all units and superunits are divided into and 13 pairs sub-units. SHIELD: Corrugated, copolymer coated aluminum tape, 8-mil ick applied longitudinally wi a gap. A flooding compound is applied over e shield. ARMOR: Corrugated shield of copolymer coated steel tape, -mil ick. A flooding compound wi adhesive properties is applied over e armor. JACKET: weight polyeylene. Sequential footage (or meter) markings are printed on e jacket at 2 foot (or 1 m) intervals. Outside plant telephony, direct burial or underground installation. Meets REA/RUS PE-89 ANSI/ICEA S Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor. Telecordia (Bellcore) equivalent: AN W ISO-1 Quality Assurance System Condumex Wire and Cable Street - Grand Prairie, TX 7 - (800)
6 2 AWG AWG AWG AWG Note: Values shown are nominal, subject to manufacturing tolerances. Special lengs are available upon request.
7 I. Exchange Cables Aircore ALPETH Cable REA/RUS PE CONDUCTORS: Solid, annealed copper wires, in 2, and 19 AWG. INSULATION: Solid, high-density polyeylene or polypropylene in distinctive colors, conforming to telephone industry standards. PAIRS: Insulated conductors are twisted togeer to form pairs, wi different twist lay lengs to minimize capacitance unbalance and crosstalk. CORE ASSEMBLY: In cables wi pairs or less, e pairs are laid forming a cylindrical shape. For larger cables, units of pairs or superunits of or pairs are assembled to form e final core. All units and superunits are identified wi color coded, non-hygroscopic, non-wicking binders. In order to have a rounder shape and better electrical performance, all units and superunits are divided into and 13 pairs sub-units. SHIELD: Corrugated, copolymer coated, 8-mil ick aluminum tape applied longitudinally wi an overlap. The coating reduces e risk of shield corrosion. JACKET: weight polyeylene. Sequential footage (or meter) markings are printed on e jacket at 2 foot (or 1 m) intervals. Meets REA/RUS PE-22 ANSI/ICEA S Standard for Telecommunications Cable Air Core, Polyolefin Insulated, Copper Conductor. Telecordia (Bellcore) equivalent: BH A ISO-1 Quality Assurance System Packaged on wooden reels wi a ermal wrap applied over e cable. The reels are also lagged for additional protection. Condumex Wire and Cable Street - Grand Prairie, TX 7 - (800)
8 8 2 AWG AWG AWG AWG Note: Values shown are nominal, subject to manufacturing tolerances. Special lengs are available upon request.
9 II. Buried Wire Double Jacketed Buried Distribution Wire (Gopher resistent) PE CONDUCTORS: Solid, annealed 22 AWG copper wi a nominal diameter of 0.00 (0.34 mm) INSULATION: Solid, high-density, polyeylene or polypropylene in distinctive colors, conforming to telephone industry standards. PAIRS: Insulated conductors are twisted togeer to form pairs, wi different twist lay lengs, wi a maximum leng of.5 (15 mm). CORE ASSEMBLY: The core is filled wi ETPR (80 C) compound, en covered wi a non-hygroscopic tape wi an overlap. A filling compound is also applied over e wrap. INNER JACKET weight polyeylene. SHIELD: Corrugated, copper-clad alloy steel (0.005 ick) tape applied longitudinally wi an overlap. A flooding compound is applied on bo sides of e tape. OUTER JACKET: Black, linear, low density, high molecular weight polyeylene. Sequential footage (or meter) markings are printed on e jacket at 2 foot (or 1 m) intervals. Service drop for telephony, underground installation or direct burial. ANSI/ICEA S Standard for Telecommunications Cable Filled, Polyolefin Insulated, Cooper Conductor. Meets REA/RUS PE-8 (for 2 and 3 pair, 22 AWG when a bronze shield - BDW B or when a cooper clad steel armor - BDW G DJ is used) ISO-1 Quality Assurance System Packaged on wooden reels at are lagged for additional protection. Condumex Wire and Cable Street - Grand Prairie, TX 7 - (800)
10 II. Buried Wire Double Jacketed Buried Distribution Wire (Gopher resistent) PE Number Of 2 3 MECHANICAL PROPERTIES Nominal Cable Net Weight Shipping Leng Approximate OD Shipping Weight In Mm Lbs/kft kg/km FT m Lbs kg or or or 2 or 70 or or or 70 or Note: Values shown are nominal, subject to manufacturing tolerances. ELECTRICAL CHARACTERISTICS MUTUAL CAPACITANCE, average nf/mile nf/km CAPACITANCE UNBALANCE: Pair to pair Maximum Individual CAPACITANCE UNBALANCE: Pair to Ground Individual Maximum FEXT Far end CROSSTALK, db/kft minimum Power khz NEXT Near end CROSSTALK, db/kft minimum Power khz 1 20 C, Maximum Individual Nominal db/kft Nominal db/km HIGH VOLTAGE TEST, d-c kv for 3 seconds Conductor to Conductor Conductor to Shield D-c CONDUCTOR 20 C, Maximum Individual Ù/kft Ù/km RESISTANCE UNBALANCE Maximum Individual Maximum Average INSULATION RESISTANCE, Minimum MÙ Mile MÙ km 80 pf/kft 145 pf/km 800 pf/kft 2 pf/km % 1.5% 1,000 1, 10
11 I. Exchange Cables Filled ASP Cable, Foam Skin Insulation DESCRIPTION: AN_W Telecordia (Bellcore) 2.AN_W.01 CONDUCTORS: Solid, annealed copper wires, in 2, 24, 22 and 19 AWG. INSULATION: Expanded polyeylene (Foam Skin) wi an external layer of solid, high-density polyeylene in distinctive colors, conforming to telephone industry standards. PAIRS: Insulated conductors are twisted togeer to form pairs, wi different twist lay lengs to minimize capacitance unbalance and cross-talk. CORE ASSEMBLY: In cables wi pairs or less, e pairs are laid forming a cylindrical shape. For larger cables, units of pairs or superunits of or pairs are assembled to form e final core. The core is filled wi ETPR (80 C) compound. Then covered wi a non-hygroscopic tape wi an overlap. Filling compound is also applied over e wrap. All units and superunits are identified wi color coded, non-hygroscopic, non-wicking binders. In order to have a rounder shape and better electrical performance, all units and super-units are divided into and 13 pair sub-units. SHIELD: Corrugated, bare aluminum tape, 8-mil ick applied longitudinally wi an overlap. A flooding compound wi adhesive properties is applied over e shield. ARMOR: A corrugated shield of steel tape, -mil ick. JACKET weight polyeylene. Sequential footage (or meter) markings are printed on e jacket at 2 foot (or 1 m) intervals. APPLICATION: Outside plant telephony, direct burial or underground installation. REFERENCE SPECIFICATIONS: Telecordia (Bellcore) TR-NWT-00421/3. ANSI/ICEA Generic Requirements for metallic telecommunication cables. CERTIFICATION: ISO-1 Quality Assurance System PACKAGING: Packaged on wooden reels wi a ermal wrap applied over e cable. The reels are also lagged for additional protection. Condumex Wire and Cable Street - Grand Prairie, TX 7 - (800)
12 2 AWG ANTW AWG , AWG AWG ANBW Note: Values shown are nominal, subject to manufacturing tolerances. Special lengs are available upon request.
13 II. Buried Wire Buried Service Wire (Aluminium shield, single jacket) BSW A 2.BSW.01 CONDUCTORS: Solid, annealed 22 AWG copper wi a nominal diameter 0.00 (0.34mm) INSULATION: Solid, high-density, polyeylene or polypropylene in distinctive colors, conforming to telephone industry standards. PAIRS: Insulated conductors are twisted togeer to form pairs, wi different twist lay lengs, wi a maximum leng of.5 (15 mm). CORE ASSEMBLY: The core is filled wi ETPR (80 C) compound. Then covered wi a nonhygroscopic tape wi an overlap. A filling compound is also applied over e wrap. SHIELD: Smoo, copolymer coated, 8-mil ick aluminum tape applied longitudinally wi an overlap. The coating reduces e risk of shield corrosion. A flooding compound wi adhesive properties is applied over e shield. JACKET: weight polyeylene, able to wistand exposure to sunlight, ground humidity and chemicals. Sequential footage (or meters) markings are printed on e jacket at 2 foot (or 1 m) intervals. Service drop for telephony, underground installation or in ducts. ANSI/ICEA S Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor. ISO-1 Quality Assurance System Packaged on wooden reels at are lagged for additional protection Condumex Wire and Cable Street - Grand Prairie, TX 7 - (800)
14 II. Buried Wire Buried Service Wire (Aluminium shield, single jacket) BSW A 2.BSW.01 Number Of 2 3 Nominal Cable Net Weight Shipping Leng Approximate OD Shipping Weight In Mm Lbs/kft kg/km FT m Lbs kg Note: Values shown are nominal, subject to manufacturing tolerances. MUTUAL CAPACITANCE, average nf/mile nf/km CAPACITANCE UNBALANCE: Pair to pair Maximum Individual CAPACITANCE UNBALANCE: Pair to Ground Individual Maximum FEXT Far end CROSSTALK, db/kft minimum Power khz NEXT Near end CROSSTALK, db/kft minimum Power khz 1 20 C, Maximum Individual Nominal db/kft Nominal db/km HIGH VOLTAGE TEST, d-c kv for 3 seconds Conductor to Conductor Conductor to Shield D-c CONDUCTOR 20 C, Maximum Individual Ù/kft Ù/km RESISTANCE UNBALANCE Maximum Individual Maximum Average INSULATION RESISTANCE, Minimum MÙ Mile MÙ km 80 pf/kft 145 pf/km 800 pf/kft 2 pf/km % 1.5% 1,000 1, 14
15 II. Buried Wire Double Jacketed Buried Distribution Wire (Aluminium shield, double polyeylene jacket) BDW A 2.BDW_A.01 DESCRIPTION: CONDUCTORS: Solid, annealed 22 AWG copper wi a nominal diameter of 0.00 (0.34mm) INSULATION: Solid, high-density, polyeylene or polypropylene in distinctive colors, conforming to telephone industry standards. PAIRS: Insulated conductors are twisted togeer to form pairs, wi different twist lay lengs, wi maximum leng of.5 (15 mm). CORE ASSEMBLY: The core is filled wi ETPR (80 C) compound. Then covered wi a nonhygroscopic tape wi an overlap. A filling compound is also applied over e wrap. INNER JACKET weight polyeylene. SHIELD: Smoo, copolymer coated, 8-mil ick aluminum tape applied longitudinally wi an overlap. The coating reduces e risk of shield corrosion. A flooding compound wi adhesive properties is applied over e shield. JACKET: weight polyeylene, able to wistand exposure to sunlight, ground humidity and chemicals. Sequential footage (or meter) markings are printed on e jacket at 2 foot (or 1 m) intervals. APPLICATION: Service drop for telephony, underground installation. REFERENCE SPECIFICATIONS: ANSI/ICEA S Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor. CERTIFICATION: ISO-1 Quality Assurance System PACKAGING: Packaged on wooden reels at are lagged for additional protection. Condumex Wire and Cable Street - Grand Prairie, TX 7 - (800)
16 II. Buried Wire Double Jacketed Buried Distribution Wire (Aluminium shield, double polyeylene jacket) BDW A 2.BDW_A.01 Number Of 2 3 MECHANICAL PROPERTIES Nominal Cable Net Weight Shipping Leng Approximate OD Shipping Weight In Mm Lbs/kft kg/km FT m Lbs kg Note: Values shown are nominal, subject to manufacturing tolerances. ELECTRICAL CHARACTERISTICS MUTUAL CAPACITANCE, average nf/mile nf/km CAPACITANCE UNBALANCE: Pair to pair Individual Maximum CAPACITANCE UNBALANCE: Pair to Ground Maximum Individual FEXT Far end CROSSTALK, db/kft minimum Power khz NEXT Near end CROSSTALK, db/kft minimum Power khz 1 20 C, Maximum Individual Nominal db/kft Nominal db/km HIGH VOLTAGE TEST, d-c kv for 3 seconds Conductor to Conductor Conductor to Shield D-c CONDUCTOR 20 C, Maximum Individual Ù/kft Ù/km RESISTANCE UNBALANCE Maximum Individual Maximum Average INSULATION RESISTANCE, Minimum MÙ Mile MÙ km 80 pf/kft 145 pf/km 800 pf/kft 2 pf/km % 1.5% 1,000 1, 1
17 II. Buried Wire Buried Service Wire (Non-shielded, non-armored, single jacket) BSW USJ 2.BSWUSJ.01 CONDUCTORS: Solid, annealed 22 AWG copper wi a, nominal diameter 0.00 (0.34mm) or 24 AWG wi a nominal diameter of (0.511 mm) INSULATION: Solid, high-density, polyeylene or polypropylene in distinctive colors, according to telephone industry standards. PAIRS: Insulated conductors are twisted togeer to form pairs, wi different twist lay lengs wi a maximum leng of.5 (15 mm). CORE ASSEMBLY: The core is filled wi ETPR (80 C) compound. Then covered wi a nonhygroscopic tape wi an overlap. A filling compound is also applied over wrap. OUTER JACKET: weight polyeylene, able to wistand exposure to sunlight, ground humidity and chemicals. Sequential footage (or meter) markings are printed on e jacket at 2 foot (or 1 m) intervals. Service drop for telephony or underground installation in ducts. ANSI/ICEA S Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor. ISO-1 Quality Assurance System On wooden reels at are lagged for additional protection. Number Of 2 4 Nominal Cable Net Weight Shipping Leng Approximate OD Shipping Weight In Mm Lbs/kft kg/km FT m Lbs kft or 2 or 305 or 70 or Note: Values shown are nominal, subject to manufacturing tolerances. Condumex Wire and Cable Street - Grand Prairie, TX 7 - (800)
18 II. Buried Wire Buried Service Wire (Non-shielded, non-armored, single jacket) BSW USJ 2.BSWUSJ.01 Number Of 2 Nominal Cable Net Weight Shipping Leng Approximate OD Shipping Weight In Mm Lbs/kft kg/km FT m Lbs kg or 2 or 305 or 70 or Note: Values shown are nominal, subject to manufacturing tolerances. 22 AWG 24 AWG MUTUAL CAPACITANCE, average nf/mile nf/km CAPACITANCE UNBALANCE: Pair to pair Maximum Individual 80 pf/kft 145 pf/km CAPACITANCE UNBALANCE: Pair to Ground Individual Maximum 800 pf/kft 2 pf/km FEXT Far end CROSSTALK, db/kft minimum Power khz 3 NEXT Near end CROSSTALK, db/kft minimum Power khz C, Maximum Individual Nominal db/kft Nominal db/km HIGH VOLTAGE TEST, d-c kv for 3 seconds Conductor to Conductor Conductor to Shield D-c CONDUCTOR 20 C, Maximum Individual Ù/kft Ù/km RESISTANCE UNBALANCE Maximum Individual Maximum Average INSULATION RESISTANCE, Minimum MÙ Mile MÙ km % 1.5% 1,000 1,
19 AERIAL SERVICE WIRE 2.ASW.01 DESCRIPTION: Bare copper 22 AWG conductors Solid, high-density polyeylene insulation Galvanized steel messenger wire 2.11mm O.D. Color coded to industry standards Sunlight-resistant PVC jacket Packaging available in reels, cartons and coils APPLICATIONS: PROPERTIES: Pair Count Extending telephone circuits from a distribution terminal to a subscriber s station protectors. Aerial applications. MECHANICAL PROPERTIES Conductor Diameter (mm) Insulation Diameter (mm) Overall Diameter (mm) * Values shown are nominal, subject to manufacturing tolerances. Net Weight (kg/km) x x 15 0 SPECIFICATIONS: Bellcore: GR-492-CORE UL Listed Bellcore: TR-NWT-0002 Quality System, ISO-0 c.d. Resistance of Conductor (ohm/km) ELECTRICAL PROPERTIES DC Resistance Unbalance Mutual Capacitance (nf/km) 5.5 5% max avg 58.4 max. ind. Capacitance Unbalance (Pair to Pair) (pf/km) Insulation Resistance (Megaohs-km) 145 max. 1 min TRANSMISSION CHARACTERISTICS Frequency KHz Attenuation db/km NEXT db/km min. FEXT db/km 58 min. Condumex Wire and Cable Street - Grand Prairie, TX 7 - (800)
Canadian OSP Copper I-1. Table of Contents
Canadian OSP Copper Premises Copper Table of Contents CELFIL BJBB, BJAB, BJMB and BJTB................................. I-2 Canadian ALPETH BHBB, BHAB, BKMB and BKTB.................... I-4 SEALPAP BHBF,
More informationCaledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:
Caledonian www.caledonian-cables.co.uk www.caledonian-cables.net Profibus L2 Indoor Application: This system cable is used to interconnect L2-BUS components. This cable is an economical solution for the
More informationAddison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:
Addison www.addison-tech.com www.addison-cables.com Profibus SK Indoor + Outdoor Application: The application of these Profibus SK cables are in the cell and field area, just as for conventional types.
More informationElectrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.
734A COAXIAL CABLE Application Intended for interconnection of transmission and switching systems equipment. Features UL listed as NEC Type CMR and CSA certified as Type CMR. NORDX/CDT 734A coaxial was
More informationCOPPER + LWL RAW CABLES
COPPER + LWL RAW Twisted Pair Cables... 112 TV/SAT Cables... 116 Fiber Optic Raw Cables... 120 DIGITUS CAT 7 twisted pair installation cable 4x2xAWG23 S-FTP CAT 7 1000 MHz LSZH installation cable For installation
More informationNETWORK CONNECTIVITY SYSTEMS
NETWORK CONNECTIVITY SYSTEMS Installation Cable KS-STP Category 7 Installation Cable Certificates 10GBaseT FTP Category 6 Installation Cable UTP Category 6 Installation Cable UTP Category 5E Installation
More informationDrop Cable Product Catalog
Drop Cable Product Catalog Table of Contents Drop Cable Product Catalog The Basics of CommScope Drop Cable... 2, 3 Drop Cable Reel Dimensions...4 Drop Cable Packaging Information... 4, 5 Explanation of
More informationData sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft
Page 1/6 MC GC0 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft 18427034141 Illustrations Principle diagram Product specification 10 GBit installation cable, simplex installation cable Cat.7 AWG 23 S/FTP with wires
More informationFor information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.
Telecommunication and fire alarm cables For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation. J-YY Bd 14 J-YY BMK 15 J-Y(St)Y Lg 16 J-Y(St)Y
More informationMEDIUM VOLTAGE
WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent
More informationK20 & L120 LSZH Armoured F/FTP Cat6 Cables
K20 & L120 LSZH Armoured F/FTP Cat6 Cables The cables are designed for high speed data transmissions, and are suitable for installations in cable trays or on hooks. RATP CAT6-K20 (for K20 cable) FRANCE
More information14 AWG 2 AWG: 600 Volt
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.70 600V Type MC Metal Clad and Teck-Style Cables Overview Metal Clad Interlocked PVC Outer Jacket Teck-Style PVC Outer Jacket Introduction Polyester Wrap
More informationCross-Connect and Distribution Frame Wire 5
Datacom Cross-Connect and Distribution Frame Wire 5 With extended experience in the field of cross-connect wires, General Cable provides a variety of indoor and outdoor UL-listed cross-connect and distributing
More information11-SDMS-03 REV. 02 SPECIFICATIONS FOR
11-SDMS-03 REV. 02 SPECIFICATIONS FOR XLPE INSULATED POWER CABLES FOR RATED VOLTAGES FROM 15 KV UP TO 36 KV (U m ) This specification is property of SEC and subject to change or modification without notice
More informationLTE high-performance coaxial cables (RG replacement)
LTE high-performance coaxial cables (RG replacement) Center Conductor: See table below. Dielectric: LTE (extruded low-density PTFE) or low density / composite. Inner Shield: 875-892: None. 900-142: Flat
More informationCORFLEX VFD CORFLEX VFD Part Number: Drive Cable
Part Number: Drive Cable Armored Variable Frequency Drive Cable UL Type MC HL, 600V, 90 C rated - LEAD FREE Description 3 conductor with 3 ground wires, continuous corrugated and welded, impervious aluminum
More informationInstrumentation Cables
around a world of cables UL INSTRUMENTATION CABLES UL THHN CABLES UL THWN CABLES Instrumentation Cables INDEX Introduction Specialty Cables 300V & 00V Instrumentation Cable Types Certificates and Standards
More informationIndex WIRE AND CABLE FOR ASSEMBLIES. Condumex Wire and Cable Street, Suite Grand Prairie, TX (800) CONTENTS
Index WIRE ND CBLE FR SSEMBLIES CNTENTS SVT JCKETED FLEXIBLE CRD SPT JCKETED FLEXIBLE CRD SPT DUPLEX FLEXIBLE CRD WITH GRUND CNDUCTR 07/1569 FLEXIBLE HK UP CNDUCTR 15 FLEXIBLE HK UP CNDUCTR 1275 HK UP
More informationMedium Voltage Power Cables
N2XSY 6/0, /20, /30 NA2XSY 6/0, /20, /30 N2XS2Y 6/0, /20, /30 NA2XS2Y 6/0, /20, /30 N2XS(F)2Y 6/0, /20, /30 NA2XS(F)2Y 6/0, /20, /30 N2XSEY 3 x 6/0 Medium Voltage Power Cables Photo: HELUKABEL Q 47 Medium
More informationCOMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationCUSTOM DESIGN COAXIAL CABLES BY SICAB
CUSTOM DESIGN COAXIAL CABLES BY SICAB. COAX RG 58 C/U Application: Coaxial Cable 50 Ohm For indoor installation as well as in industrial areas in conduits and cable ducts, for transmission of high frequency
More informationData sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2
Page 1/7 Illustrations Principle diagram See enlarged drawings at the end of document Product specification 10 GBit installation cable, simplex installation cable Cat.7A AWG 22 S/FTP with wires shielded
More information3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded (CCW) Type Cables*)
Design Parameters Description Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX
More informationDetailed Specifications & Technical Data
For more Information please call 1-800-Belden1 General Description: PTZ (CCTV+Control+Power) Cable, Rated-CM, 1-RG59 20 AWG solid bare copper with foam polyolefin, 95% bare copper braid, 1-22 AWG stranded
More informationSBCA Industry Standards Subcommittee. Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations
SBCA Industry Standards Subcommittee Document: SBCA Series 6 Recommended Practices Date of Issue: Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations
More information2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties
2. CONDUCTORS 2.1 Strand Types 2.1.1 Concentric Strand 7 2.1.2 Bunch Strand 7 2.1.3 Rope Strand 8 2.1.4 Sector Conductor 8 2.1.5 Segmental Conductor 8 2.1.6 Annular Conductor 8 2.1.7 Compact Strand 8 2.1.8
More information3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded Type Cables*)
Design Parameters Description Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX
More informationTwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm
name: TKF article number: 10305 description Nr.: POE- PS- 10305 PT F F F 800 B C 1 2 3 4 5 6 7 Assembly: 1. Primary tube 5 mm 2. CAT 5 E FTP cable 3. CAT 5 E FTP cable 4. Bus cable 5. Coax 9 cable 6. Separation
More informationCopperclad Steel Wire High Strength/Extra High Strength
Copperclad Steel Wire High Strength/Extra High Strength High Strength (HS) and Extra High Strength (EHS) copperclad steel wire provides the same conductivity and corrosion resistance as copper while maintaining
More informationGO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry
GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry ADC is a proud Sustaining Member of the IMSA organization and is the largest manufacturer in
More informationCAT 5e UTP Cable: NETSET BOX [305m], indoor
Code: E08_05 CAT 5e UTP Cable: NETSET BOX [05m], indoor NETSET BOX UTP 5e Ethernet cable far exceeds the requirements for Category 5e twisted pair cables. View of the cable box - inside 05m of the cable.
More informationField Instrument Cable. Electrical Noise
Field Instrument Cable Electrical Noise 1 Electrical Noise Instrument Cables are Susceptible to 4 Types of Noise: Static Magnetic Cross-Talk Common Mode 2 Static Noise Static Noise is caused by an electric
More informationPRELIMINARIES. Generators and loads are connected together through transmission lines transporting electric power from one place to another.
TRANSMISSION LINES PRELIMINARIES Generators and loads are connected together through transmission lines transporting electric power from one place to another. Transmission line must, therefore, take power
More information600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables
Applications Multiconductor cable with stranded copper conductors, extruded high dielectric strength cross-linked polyethylene (XLPE) insulation, Type XHHW-2, cabled with bare copper grounding conductors
More informationData sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft
Page 1/7 Illustrations Principle diagram Product specification 10 GBit installation cable, duplex installation cable Cat.7A AWG 22 S/FTP with wires shielded in pairs 2x4 pairs (PiMF) pair shield: plastic
More informationEXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)
XTRA GUARD 1 MULTICONDUCTOR, SUPRASHIELD EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE UL TYPE CM, AWM 2464 CSA CMG FT4 300 VOLT 34 CHOOSE XTRA GUARD 1FOR: Unsurpassed Flame and Moisture Resistance
More informationLV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments
ife? No S n K P r o ble m! No? aw a proven, rugged product for harsh environments No LV AIRGUARD LV AIRGUARD Low Voltage Cables for Harsh Environments FEATURES - No Knife? No Saw? No Problem! installation
More informationFOR INTERCONNECT AND CROSS-CONNECT APPLICATIONS
FOR INTERCONNECT AND CROSS-CONNECT APPLICATIONS HIGH SPEED DS-3 & DS-4 CABLES Belden Your Widest Selection for Meeting DS-3 and DS-4 Network Requirements BELDEN, THE CABLE TECHNOLOGY LEADER IN HIGH-SPEED
More informationC400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR
C400-UMUM-100 Product Classification Brand Product Series Product Type CNT Jumper with interface types UHF Male and UHF Male, 30.48 m CNT Braided cable assembly General Specifications Body Style, Connector
More informationDetailed Specifications & Technical Data
Description: Series 11, 14 AWG solid.064" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond IV quad shield (60% and 40% coverage), PVC jacket Physical Characteristics
More informationAVA5-50FX. Product Classification. Standards And Qualifications. Construction Materials. Dimensions. Electrical Specifications
AVA5RK-50FX, HELIAX Andrew Virtual Air Coaxial Cable, corrugated copper, 7/8 in, black, Non-halogenated, fire retardant polyolefin jacket B2ca-s1b,d1 Product Classification Brand Product Series Product
More informationInformation technology. Generic cabling systems, General requirements
KRAMER WELL CONNECTED WITH KRAMER BCLS-33OR-5 Al-Mylar Conductor CAT6A F/UTP LSZH Cable Drain Wire Kramer s BCLS-33OR is a high performance CAT6A F/UTP cable designed for IT, LAN and Ethernet installations.
More informationOutdoor, CCTV or CCTV, Fig 8 Armored.
Outdoor, CCTV or CCTV, Fig 8 Armored. Outdoor stranded Fig 8 Armored, Fiber optic cable for aerial installation. It support application such as IEEE802.3, 10G Ethernet, Gigabit Ethernet, Fast Ethernet,
More informationAddison Medium Voltage Cables
Addison Medium Voltage Cables www.addison-cables.com www.addison-tech.com 1 Caledonian Medium Voltage Cables(ICEA) Company Profile Caledonian. established in 1978.offers one of the most complete lines
More informationCIR (Crush & Impact Resistant) VFD Power Cable
37-2 CIRVFD CIR (Crush & Impact Resistant) VFD Power Cable Gexol Insulated Three Conductor 2kV Rated 90 C UL Listed as Type TC-ER Power Conductors (x3) Soft annealed flexible stranded tinned copper per
More informationKerman & Kavian Cable Industries ( KCI )
KCI Kerman & Kavian Cable Industries ( KCI ) KCI Cables for control and instrumentation circuits 150/250 V (300 V) According to of IEC 60092-376 (2003) Electrical installations in ships - Part 376: Kerman
More informationConnection technology for wireless communication systems
Connection technology for wireless communication systems Rosenberger Rosenberger, founded in 1958, is a family owned company and ranks today among the top global manufacturers of high-frequency coaxial
More informationEC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s
EC 200 EC200 - Rev. 3-23.06.11 Characteristic impedance 50 ± 2 Material copper wire Nominal capacity (pf/m) 80.5 Construction - Relative propagation velocity (%) 83 Diameter (mm) 1.05 Inductance (µh/m)
More informationContent. - DDF Frame Pair Screen Cable Pair Screen Cable
Content - 120 1.1 Ohm 120ohm DDF DDF Accessories Cables 1.1.1 2 Pair Screen Cable - DDF Frame 1.1.2 4 Pair Screen Cable - 120 Ohm 1.1.3 DDF 8 Pair Cable Screen Cable 1.1.4 16 Pair Screen Cable 1.1.5 50
More informationStandard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables
Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES ( Data Sheets ) 11 kv XLPE-Insulated Three-Core Underground Cables (3x240 mm 2 ) ADWEA/ADDC/AADC STANDARD : D-AAA-CAB-11-3Cx240
More informationCCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations
CCW Continuously Corrugated Welded Cable Armored Cable for Hazardous Locations CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the most comprehensive line
More information5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables
5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables Applications Three copper conductors cable, each with a semiconducting conductor shield, high dielectric strength VOLTALENE TRXLPE
More informationALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers
Features and Benefits Fully waterblocked loose tube, gel-free design Simple access and no clean up Single-armored construction Provides additional crush and rodent protection High-strength ripcord Ease
More informationSECTION COMMUNICATIONS COPPER BACKBONE CABLING
SECTION 27 13 13 COMMUNICATIONS COPPER BACKBONE CABLING PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such
More informationJULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.
FOREWORD This Standard is intended to be used within and for Iranian Ministry of Petroleum (N.I.O.C, N.I.G.C, N.P.C., N.I.O.R.D.C. and other affiliate organizations and companies) and has been prepared
More information5-46kV 3/C TRXLPE POWER CSA Medium Voltage Commercial & Industrial Cables
5-46kV 3/C TRXLPE POWER CSA Medium Voltage Commercial & Industrial Cables Description Three conductor cable with stranded copper or aluminum conductors, triple extruded insulation system consisting of
More informationfeatures and benefits
features and benefits Fully waterblocked loose tube, gel-free design Medium-density polyethylene jacket Figure-8 cable design Available in 62.5 µm, 50 µm, single-mode and hybrid versions Simple access
More informationFiber Optic Outside Plant Cables (4-144 Fibers)
Fiber Optic Outside Plant Cables (4-144 ) Central Tube Dielectric Cable 4-12 Fiber Water Blocking Strength Members Multi-Tube Dielectric Cable 24-216 Fiber The number of tubes changes depending on fiber
More informationMongoose PT Platform Shale Shaker
Mongoose PT Platform Shale Shaker (UL VERSION) Revision: A By: MT Mongoose Platform Page 1 of 10 NOTE: Mongoose PT Platform Shale Shaker The attached is a reference to M-I SWACO s STANDARD Mongoose Platform
More informationSingle-Armored Cables, Fibers
Features and Benefits Fully waterblocked loose tube, gel-free design Simple access and no clean up Single-armored construction Provides additional crush and rodent protection High-strength ripcord Ease
More information600 Volt MULTICONDUCTOR EPR MC Low Voltage Commercial & Industrial Cables
Applications Multiconductor cable with stranded copper conductors, extruded high dielectric strength thermosetting EPR-based insulation, Type XHHW-2, cabled with bare copper grounding conductors and fillers,
More informationC400-TMTM-30-X. Jumper Assembly Sample Label. Product Classification. General Specifications. Electrical Specifications
C400-TMTM-30-X Product Classification Brand Product Series Product Type CNT-400-FR CNT Jumper with interface types TNC Male and TNC Male, 9.14 m CNT CNT-400 Braided cable assembly General Specifications
More informationCABLE.
CABLE www.pcnet-cable.com.tw sales@pcnet-cable.com.tw PCnet Leading Your Net! PCnet was founded in 1985 and is a leading manufacturer of netwking industries. We provide a complete range of products f structured
More informationSECTION COMMUNICATIONS COPPER BACKBONE CABLING
PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications shall include all labor necessary to perform and complete such construction, all materials and equipment incorporated
More informationContinuous Flex Data Cable
1,! gti',',n Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA 080--Main Office: () 88-00-Outside Local Area: (800) 8-00-www.stevenengineering.com Continuous Flex Data Cable UNITRONIC
More information1) The addition of TCL and ELTCTL requirements to Category 6
Subject 444 TO: SUBJECT: 455 East Trimble Road San Jose, CA 95131 July 28, 2008 Subscribers to UL s Listing and Verification Services for Communications Cable (DUZX) Revised Test and Follow-Up Service
More informationDOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES
DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES El Dorado, Arkansas Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology
More informationCOPPERCLAD STEEL WIRE. Dead Soft Annealed Jacketed High Strength. Extra High Strength Composite Conductors Guy Wire
COPPERCLAD STEEL WIRE Dead Soft Annealed Jacketed High Strength Extra High Strength Composite Conductors Guy Wire Founded in 1984, AFL is an international manufacturer providing end-to-end solutions to
More informationDetailed Specifications & Technical Data
For more Information please call 1-800-Belden1 Description: Banana Peel Composite - (2) Cat 5e 4-pair 24 AWG unshielded plus (2) Series 6 Coax with Duobond IV Quad shield, polyolefin insulation on the
More informationInstrumentation Cable PLTC/ITC and TC Types
Instrumentation Cable PLTC/ITC and TC Types The Quality Connection 2 The Quality Connection Product range Telecommunication cables Data- and Bus cables (copper and fiber optic) Mining cables Cables for
More informationMGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES 1. Qualifying Requirement of AB Cable Manufacture/Supplier The manufacturer should have manufactured, successfully type tested
More informationCoated Dead-end NOMENCLATURE GENERAL RECOMMENDATIONS
NOMENCLATURE Crossover Marks: Indicate starting point for application. Gritted and Neoprene Dipped Legs: Grit is permanently embedded in a coating of neoprene. GENERAL RECOMMENDATIONS Coated Dead-ends:
More information012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)
012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 8051 Fax: +94 11 232 5387 CONTENTS Page 1.0
More informationDetailed Specifications & Technical Data
Description: 24 AWG stranded (7x32) TC conductor, Datalene insulation, pairs individually shielded with bonded Beldfoil with a drain wire and have numbered and color-coded PVC jackets, overall Beldfoil
More informationDETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, TWELVE INDIVIDUALLY SHIELDED PAIRS 22 (7 X 30) AWG
INCH-POUND MIL-DTL-49285/22B 27 March 2018 SUPERSEDING MIL DTL 49285/22A 1 March 2010 DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, TWELVE INDIVIDUALLY SHIELDED PAIRS 22 (7 X 30) AWG Inactive
More informationCoax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3
Overview Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3 Example drawing (see the chapter belonging to the cable for details) (see the chapter belonging
More informationENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 177 2012 Specification for Braided 75 Ω, Mini-Series Quad Shield Coaxial Cable for CMTS and SDI cables NOTICE
More informationCoaxial Cables. Coaxial Cables. & Addison.
Coaxial Cables Coaxial Cables & Addison www.caledonian-cables.co.uk www.caledonian-cables.net www.addison-cables.net www.addison-cables.com 1 Company Profile Coaxial Cabless. established in 1978.offers
More informationGEXOL WORLD CLASS OIL & GAS CABLES
GEXOL WORLD CLASS OIL & GAS CABLES Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant
More informationGameChanger Cable. Unshielded Twisted Pair Riser Rated - CMR PRYWB (legacy part no)
GameChanger Cable Unshielded Twisted Pair Riser Rated - CMR 258310333 46224PRYWB (legacy part no) 1.0 Scope 1.1 This cable consists of 4 pair solid bare copper; color-coded high density polyethylene (HDPE)
More informationIGS. IGS-M-IT-008(1) Sep Communication Cables (Telephone and Data Transmission ) Approved مصوب. Fax:(9821)
IGS-M-IT-008(1) Sep. 2016 Approved مصوب شركت ملي گازايران مديريت پژوهش و فنĤوري امورتدوين استانداردها IGS مشخصات فني خريد كابلهاي مخابراتي ) خطوط تلفن و انتقال اطلاعات ( Communication Cables (Telephone
More informationTo offer our customer the highest quality Broadband products at a competitive price with efficient Delivery and Inventory.
ALANTEK COMMUNICATIONS Founded in 1998 and headquartered in the USA, is a professional manufacturer of Broadband Coaxial Cables & Accessories. Its strength th in engineering and manufacturing is reflected
More informationIndustrial Data Solutions Industrial Ethernet Cables Category 5e DataTuff Twisted Pair Cables Heavy Duty Sunlight- and Oil-Resistant Jackets
I N D U S T R I A L C A B L E S 18.7 Cat 5e 24 AWG Bonded-Pair Solid 0.5 Bare Copper Polyethylene Insulation Industrial Grade Sunlight- and Oil-Resistant FRNC /LSNH Jacket (Black and Grey) Diaeter Noinal
More informationTECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)
TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm 2 + 80mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of, 3C x95mm 2 +
More informationCAT. 5e U/UTP 4x2x24AWG/1 CCA DOUBLE SHEATH
CAT. 5e U/UTP 4x2x24AWG/1 CCA DOUBLE SHEATH FIGURE CONSTRUCTION Inner conductor CCA Φ 0.50±0.01mm Insulation Solid HDPE Φ 0.90±0.05mm Color 1 Blue & White/ Blue 2 Orange & White/ Orange 3 Green & White/
More informationStandards Update Notice (SUN) Issued: June 6, 2017
Standard Information Standard Number: UL 758 Standard Name: Standard for Safety for Appliance Wiring Material Standard Edition and Issue Date: 3 rd Edition Dated May 2, 2014 Date of Revisions: 2 nd Ed.
More informationInstall & Go Cat.8 S/FTP Trunk Cable Assembly Description
Description Cat 8 Filler Cat.8.2 S/FTP Horizontal cables (x6) Fan-Out Cables Cat 8 STP Keystones TRUNK CABLE SECTION VIEW Assembly Isometric Front View RiT s Copper Install & Go System provides a pre-terminated
More informationFireproof Cables (Fire Resistant LSOH Sheathed Cables) КИФнг(A)-HF for RS485
Content Page Certificates 3 Industrial Cables Production 4-5 Industrial Cables of PJSC «Odeskabel» 6 КИФ-В for RS485 (CAN) КИФ-В 1х2х0,6; КИФ-В 1,5х2х0,6; КИФ-В 2х2х0,6; КИФ-В 3х,2х0,6; КИФ-В 4х2х0,6 8
More informationPOLYIMIDE INSULATED WIRES AND CABLES, LOW FREQUENCY, 600V, -200 TO +200 C BASED ON TYPE SPL. ESCC Detail Specification No.
Page 1 of 23 POLYIMIDE INSULATED WIRES AND CABLES, LOW FREQUENCY, 600V, -200 TO +200 C BASED ON TYPE SPL ESCC Detail Specification Issue 3 May 2013 Document Custodian: European Space Agency see https://escies.org
More informationMESP TECHNICAL SPECIFICATION FOR MURL JUMPER WIRE HARD-DRAWN COPPER 19/ mm 2
Engineering Specification Electrical Networks MESP 130400-07 TECHNICAL SPECIFICATION FOR Version: 1 Issued: February 2017 Owner: Engineering Division Approved By: Andrew Russack Head of Engineering (Electrical)
More informationC400-NMTM-1M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR
C400-NMTM-1M Product Classification Brand Product Series Product Type CNT-400 CNT Jumper with interface types N Male and TNC Male, 1m CNT CNT-400 Braided cable assembly General Specifications Body Style,
More information* Peaks of 1.3mm MAX allowed only in a rate of 2% or less
COAXIAL CABLE 50 OHM LOW LOSS 956163-3 A C 800275 Rev: D. 08 October 2014 Rev: C Maximum MHz db/100m MHz db/100m 100 16.3 1000 56.5 200 23.5 1500 70.2 500 38.2 1800 77.2 800 49.5 2000 81.5 Diameter of
More informationSUPERIOR MARINE CABLE SOLUTIONS
SUPERIOR MARINE CABLE SOLUTIONS FLEXIBLE FINE STRANDED Horizon Maximus II Company Profile Through over 35 years of history and experience, we have built a renowned reputation for supplying superior cables
More informationC195-SMQM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR
C195-SMQM-3M Product Classification Brand Product Series Product Type CNT-195 CNT Jumper with interface types SMA Male and QMA Male, 3M CNT CNT-195 Braided cable assembly General Specifications Body Style,
More informationP Low Voltage Catalogue Cables Australia Powering your Project
P +61 8 9367 8978 Low Voltage Catalogue Cables Australia Powering your Project CABLES AUSTRALIA PTY LTD LOW VOLTAGE CATALOGUE ABOUT US Cables Australia is a locally owned and operated distributor of high
More informationShip Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4
Wiking Ship Hybrid Cable Application Hybrid cable for shipboard applications DATA ELEMENT Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T
More informationC240-NFSM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR
C240-NFSM-3M Product Classification Brand Product Series Product Type CNT Jumper with interface types N Female and SMA Male, 3m CNT Braided cable assembly General Specifications Body Style, Connector A
More informationOutdoor, Fig 8 Armored, Multi Tube
Outdoor, Fig 8 Armored, Multi Tube Outdoor stranded Fig 8 Armored, Fiber optic cable for aerial installation. It support application such as IEEE802.3, 10G Ethernet, Gigabit Ethernet, Fast Ethernet, Ethernet,
More informationDetailed Specifications & Technical Data
RFP Specification #17-11125-C, Exhibit 2 Programmable Light Poles for BART Plaza ENGLISH MEASUREMENT VERSION 1502SB Multi-Conductor - Multimedia Control Cable For more Information please call 1-800-Belden1
More informationPage 1 of 5 Application Engineering Note Proc. 001 Interlock Armor and Corrugated Steel Tape Cables Pulling Grip Installation Procedure Rev.
Page 1 of 5 Scope: The scope of this procedure is to describe how to properly install a cable pulling grip on an Optical Cable Corporation interlocked armor (ILA) and corrugated steel tape (CST) fiber
More information