5-46kV 3/C TRXLPE POWER CSA Medium Voltage Commercial & Industrial Cables
|
|
- Collin Doyle
- 5 years ago
- Views:
Transcription
1 5-46kV 3/C TRXLPE POWER CSA Medium Voltage Commercial & Industrial Cables Description Three conductor cable with stranded copper or aluminum conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength VOLTALENE TRXLPE insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductor(s), overall binder tape, and overall PVC jacket. Specifications CSA- CSA C68.10 Ratings FT1-40 C Sunlight Resistant For continuous, 130 C emergency, 250 C short-circuit operation. Options - Strandseal - Super smooth conductor shield - EPROTENAX (EPR) insulation - Zero or three grounding conductor(s) - Colored Jackets - LLDPE, CPE or LSOH Jacket - Copper tape shield with 20% overlap - Mine Power Feeder (MP, MP-GC) - Lead Sheath or Armour Installation in Air Underground Wet Locations With Messenger Direct Buried in Air Dry Locations Industrial Design Parameters CONDUCTOR: Class B Compressed concentric strand aluminum alloy 1350 or compact concentric soft drawn annealed copper per ASTM. CONDUCTOR SHIELD: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. INSULATION: Natural high dielectric strength tree-retardant cross-linked polyethylene (TRXLPE) VOLTALENE insulation, exhibiting an optimum balance of mechanical and electrical properties, insuring resistance to treeing. INSULATION SHIELD: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. METALLIC SHIELD: Helically applied non-magnetic copper tape over the insulation shield with a maximum 15% gap. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w/red, 1C w/blue, and 1C w/black. ASSEMBLY: Phase identified shielded conductors cabled with fillers forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability. JACKET: Black, sunlight resistant, polyvinyl chloride (PVC) jacket tightly applied the binder tape. 1
2 5kV 3/C TRXLPE POWER CSA Diameter (mm) 5kV 100%/133% Copper Three Q4256ZC 4 AWG CU Q4456ZC 2 AWG CU Q4656ZC 1 AWG CU Q4856ZC 1/0 AWG CU Q4956ZC 2/0 AWG CU Q4A56ZC 3/0 AWG CU Q4B56ZC 4/0 AWG CU Q4C56ZC 250 MCM CU Q4D56ZC 350 MCM CU Q4E56ZC 500 MCM CU Q4F56XC 750 MCM CU Q4G56XC 1000 MCM CU Underground per 2011 NEC Table (C)(79): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(75): Single three-conductor per 2011 NEC Table (C)(71): Single three-conductor 2
3 5kV 3/C TRXLPE POWER CSA Diameter (mm) 5kV 100%/133% Aluminum Three Q4K56ZC 4 AWG AL Q4M56ZC 2 AWG AL Q4O56ZC 1 AWG AL Q4Q56ZC 1/0 AWG AL Q4R56ZC 2/0 AWG AL Q4S56ZC 3/0 AWG AL Q4T56ZC 4/0 AWG AL Q4U56ZC 250 MCM AL Q4V56ZC 350 MCM AL Q4W56ZC 500 MCM AL Q4X56ZC 750 MCM AL Q4Y56ZC 1000 MCM AL Underground per 2011 NEC Table (C)(80): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(76): Single three-conductor per 2011 NEC Table (C)(72): Single three-conductor 3
4 8kV 3/C TRXLPE POWER CSA Diameter (mm) 8kV 100% Copper Three Q5256ZC 4 AWG CU Q5456ZC 2 AWG CU Q5656ZC 1 AWG CU Q5856ZC 1/0 AWG CU Q5956ZC 2/0 AWG CU Q5A56ZC 3/0 AWG CU Q5B56ZC 4/0 AWG CU Q5C56ZC 250 MCM CU Q5D56ZC 350 MCM CU Q5E56ZC 500 MCM CU Q5F56XC 750 MCM CU Q5G56XC 1000 MCM CU kV 133% Copper Three Q6456ZC 2 AWG CU Q6656ZC 1 AWG CU Q6856ZC 1/0 AWG CU Q6956ZC 2/0 AWG CU Q6A56ZC 3/0 AWG CU Q6B56ZC 4/0 AWG CU Q6C56ZC 250 MCM CU Q6D56ZC 350 MCM CU Q6E56ZC 500 MCM CU Q6F56XC 750 MCM CU Q6G56XC 1000 MCM CU Underground per 2011 NEC Table (C)(79): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(75): Single three-conductor per 2011 NEC Table (C)(71): Single three-conductor 4
5 8kV 3/C TRXLPE POWER CSA Diameter (mm) 8kV 100% Aluminum Three Q5K56ZC 4 AWG AL Q5M56ZC 2 AWG AL Q5O56ZC 1 AWG AL Q5Q56ZC 1/0 AWG AL Q5R56ZC 2/0 AWG AL Q5S56ZC 3/0 AWG AL Q5T56ZC 4/0 AWG AL Q5U56ZC 250 MCM AL Q5V56ZC 350 MCM AL Q5W56ZC 500 MCM AL Q5X56ZC 750 MCM AL Q5Y56ZC 1000 MCM AL kV 133% Aluminum Three Q6M56ZC 2 AWG AL Q6O56ZC 1 AWG AL Q6Q56ZC 1/0 AWG AL Q6R56ZC 2/0 AWG AL Q6S56ZC 3/0 AWG AL Q6T56ZC 4/0 AWG AL Q6U56ZC 250 MCM AL Q6V56ZC 350 MCM AL Q6W56ZC 500 MCM AL Q6X56ZC 750 MCM AL Q6Y56ZC 1000 MCM AL Underground per 2011 NEC Table (C)(80): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(76): Single three-conductor per 2011 NEC Table (C)(72): Single three-conductor 5
6 15kV 3/C TRXLPE POWER CSA Diameter (mm) 15kV 100% Copper Three Q7456ZC 2 AWG CU Q7656ZC 1 AWG CU Q7856ZC 1/0 AWG CU Q7956ZC 2/0 AWG CU Q7A56ZC 3/0 AWG CU Q7B56ZC 4/0 AWG CU Q7C56ZC 250 MCM CU Q7D56ZC 350 MCM CU Q7E56ZC 500 MCM CU Q7F56XC 750 MCM CU Q7G56XC 1000 MCM CU kV 133% Copper Three Q8456ZC 2 AWG CU Q8656ZC 1 AWG CU Q8856ZC 1/0 AWG CU Q8956ZC 2/0 AWG CU Q8A56ZC 3/0 AWG CU Q8B56ZC 4/0 AWG CU Q8C56ZC 250 MCM CU Q8D56ZC 350 MCM CU Q8E56ZC 500 MCM CU Q8F56XC 750 MCM CU Q8G56XC 1000 MCM CU Underground per 2011 NEC Table (C)(79): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(75): Single three-conductor per 2011 NEC Table (C)(71): Single three-conductor 6
7 15kV 3/C TRXLPE POWER CSA Diameter (mm) 15kV 100% Aluminum Three Q7M56ZC 2 AWG AL Q7O56ZC 1 AWG AL Q7Q56ZC 1/0 AWG AL Q7R56ZC 2/0 AWG AL Q7S56ZC 3/0 AWG AL Q7T56ZC 4/0 AWG AL Q7U56ZC 250 MCM AL Q7V56ZC 350 MCM AL Q7W56ZC 500 MCM AL Q7X56ZC 750 MCM AL Q7Y56ZC 1000 MCM AL kV 133% Aluminum Three Q8M56ZC 2 AWG AL Q8O56ZC 1 AWG AL Q8Q56ZC 1/0 AWG AL Q8R56ZC 2/0 AWG AL Q8S56ZC 3/0 AWG AL Q8T56ZC 4/0 AWG AL Q8U56ZC 250 MCM AL Q8V56ZC 350 MCM AL Q8W56ZC 500 MCM AL Q8X56ZC 750 MCM AL Q8Y56ZC 1000 MCM AL Underground per 2011 NEC Table (C)(80): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(76): Single three-conductor per 2011 NEC Table (C)(72): Single three-conductor 7
8 25kV 3/C TRXLPE POWER CSA Diameter (mm) 25kV 100% Copper Three Q9656ZC 1 AWG CU Q9856ZC 1/0 AWG CU Q9956ZC 2/0 AWG CU Q9A56ZC 3/0 AWG CU Q9B56ZC 4/0 AWG CU Q9C56ZC 250 MCM CU Q9D56ZC 350 MCM CU Q9E56ZC 500 MCM CU Q9F56XC 750 MCM CU kV 133% Copper Three QA656ZC 1 AWG CU QA856ZC 1/0 AWG CU QA956ZC 2/0 AWG CU QAA56ZC 3/0 AWG CU QAB56ZC 4/0 AWG CU QAC56ZC 250 MCM CU QAD56ZC 350 MCM CU QAE56ZC 500 MCM CU QAF56XC 750 MCM CU Underground per 2011 NEC Table (C)(79): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(75): Single three-conductor per 2011 NEC Table (C)(71): Single three-conductor 8
9 25kV 3/C TRXLPE POWER CSA Diameter (mm) 25kV 100% Aluminum Three Q9O56ZC 1 AWG AL Q9Q56ZC 1/0 AWG AL Q9R56ZC 2/0 AWG AL Q9S56ZC 3/0 AWG AL Q9T56ZC 4/0 AWG AL Q9U56ZC 250 MCM AL Q9V56ZC 350 MCM AL Q9W56ZC 500 MCM AL Q9X56ZC 750 MCM AL Q9Y56ZC 1000 MCM AL kV 133% Aluminum Three QAO56ZC 1 AWG AL QAQ56ZC 1/0 AWG AL QAR56ZC 2/0 AWG AL QAS56ZC 3/0 AWG AL QAT56ZC 4/0 AWG AL QAU56ZC 250 MCM AL QAV56ZC 350 MCM AL QAW56ZC 500 MCM AL QAX56ZC 750 MCM AL Underground per 2011 NEC Table (C)(80): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(76): Single three-conductor per 2011 NEC Table (C)(72): Single three-conductor 9
10 28kV 3/C TRXLPE POWER CSA Diameter (mm) 28kV 100% Copper Three QV656ZC 1 AWG CU QV856ZC 1/0 AWG CU QV956ZC 2/0 AWG CU QVA56ZC 3/0 AWG CU QVB56ZC 4/0 AWG CU QVC56ZC 250 MCM CU QVD56ZC 350 MCM CU QVE56ZC 500 MCM CU QVF56XC 750 MCM CU kV 133% Copper Three QB656ZC 1 AWG CU QB856ZC 1/0 AWG CU QB956ZC 2/0 AWG CU QBA56ZC 3/0 AWG CU QBB56ZC 4/0 AWG CU QBC56ZC 250 MCM CU QBD56ZC 350 MCM CU QBE56ZC 500 MCM CU Underground per 2011 NEC Table (C)(79): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(75): Single three-conductor per 2011 NEC Table (C)(71): Single three-conductor 10
11 28kV 3/C TRXLPE POWER CSA Diameter (mm) 28kV 100% Aluminum Three QVO56ZC 1 AWG AL QVQ56ZC 1/0 AWG AL QVR56ZC 2/0 AWG AL QVS56ZC 3/0 AWG AL QVT56ZC 4/0 AWG AL QVU56ZC 250 MCM AL QVV56ZC 350 MCM AL QVW56ZC 500 MCM AL QVX56ZC 750 MCM AL QVY56ZC 1000 MCM AL kV 133% Aluminum Three QBO56ZC 1 AWG AL QBQ56ZC 1/0 AWG AL QBR56ZC 2/0 AWG AL QBS56ZC 3/0 AWG AL QBT56ZC 4/0 AWG AL QBU56ZC 250 MCM AL QBV56ZC 350 MCM AL QBW56ZC 500 MCM AL QBX56ZC 750 MCM AL Underground per 2011 NEC Table (C)(80): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(76): Single three-conductor per 2011 NEC Table (C)(72): Single three-conductor 11
12 35kV 3/C TRXLPE POWER CSA Diameter (mm) 35kV 100% Copper Three QB856ZC 1/0 AWG CU QB956ZC 2/0 AWG CU QBA56ZC 3/0 AWG CU QBB56ZC 4/0 AWG CU QBC56ZC 250 MCM CU QBD56ZC 350 MCM CU QBE56ZC 500 MCM CU kV 133% Copper Three QC856ZC 1/0 AWG CU QC956ZC 2/0 AWG CU QCA56ZC 3/0 AWG CU QCB56ZC 4/0 AWG CU QCC56ZC 250 MCM CU QCD56ZC 350 MCM CU QCE56ZC 500 MCM CU Underground per 2011 NEC Table (C)(79): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(75): Single three-conductor per 2011 NEC Table (C)(71): Single three-conductor 12
13 35kV 3/C TRXLPE POWER CSA Diameter (mm) 35kV 100% Aluminum Three QBQ56ZC 1/0 AWG AL QBR56ZC 2/0 AWG AL QBS56ZC 3/0 AWG AL QBT56ZC 4/0 AWG AL QBU56ZC 250 MCM AL QBV56ZC 350 MCM AL QBW56ZC 500 MCM AL QBX56ZC 750 MCM AL kV 133% Aluminum Three QCQ56ZC 1/0 AWG AL QCR56ZC 2/0 AWG AL QCS56ZC 3/0 AWG AL QCT56ZC 4/0 AWG AL QCU56ZC 250 MCM AL QCV56ZC 350 MCM AL QCW56ZC 500 MCM AL Underground per 2011 NEC Table (C)(80): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(76): Single three-conductor per 2011 NEC Table (C)(72): Single three-conductor PRYSMIAN - A Brand of The All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of. The information is believed correct at the time of issue. reserves the right to amend any specifications without notice. These specifications are not contractually valid unless authorized by. Issued June
POWER CSA. Jacket Black sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.
5-46kV 1/C TRXLPE July 2002 Description Design Parameters Options Single conductor cable with stranded copper or aluminum conductor, triple extruded insulation system consisting of a thermosetting semiconducting
More information5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables
5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables Applications Three copper conductors cable, each with a semiconducting conductor shield, high dielectric strength VOLTALENE TRXLPE
More information600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables
Applications Multiconductor cable with stranded copper conductors, extruded high dielectric strength cross-linked polyethylene (XLPE) insulation, Type XHHW-2, cabled with bare copper grounding conductors
More information5-35kV 1/C TRXLE MV-90 POWER (wire shield) Medium Voltage Commercial & Industrial Cables
5-35kV 1/C TRXLE MV-90 POWER (wire shield) Medium Voltage Commercial & Industrial Cables Description Single conductor cable with stranded copper or aluminum conductor, triple extruded insulation system
More information3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded (CCW) Type Cables*)
Design Parameters Description Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX
More information600 Volt MULTICONDUCTOR EPR MC Low Voltage Commercial & Industrial Cables
Applications Multiconductor cable with stranded copper conductors, extruded high dielectric strength thermosetting EPR-based insulation, Type XHHW-2, cabled with bare copper grounding conductors and fillers,
More information3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded Type Cables*)
Design Parameters Description Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX
More information5-35kV 1/C EPR MV-105 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables
5-35kV 1/C EPR MV-105 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables Description Single conductor cable with stranded copper or aluminum conductor, triple extruded insulation system
More information5-35kV 1/C TRXLE MV-90 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables
5-35kV 1/C TRXLE MV-90 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables Description Single conductor cable with stranded copper or aluminum conductor, triple extruded insulation system
More informationMV-105 Power. (Tape Shield) 5-35kV 1/C EPR. Design Parameters. Description. Options. Installations
5-35kV MV-105 Power (Tape Shield) 20120124 Description Design Parameters Options Single conductor cable with stranded copper or aluminum conductor, triple extruded insulation system consisting of a thermosetting
More informationAddison Medium Voltage Cables
Addison Medium Voltage Cables www.addison-cables.com www.addison-tech.com 1 Caledonian Medium Voltage Cables(ICEA) Company Profile Caledonian. established in 1978.offers one of the most complete lines
More informationCATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables
CATALOG OF PRODUCTS Isolated Copper Wire THHN/MTW/THWN-2 600V, single conductor having flame-retardant and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material.
More informationCORFLEX VFD CORFLEX VFD Part Number: Drive Cable
Part Number: Drive Cable Armored Variable Frequency Drive Cable UL Type MC HL, 600V, 90 C rated - LEAD FREE Description 3 conductor with 3 ground wires, continuous corrugated and welded, impervious aluminum
More informationTIGER BRAND MINING CABLES
TIGER BRAND MINING CABLES 5-kV TYPE SHD-GC & MP-GC -55 TYPE SHD-GC /C MOLD-CURED CPE JACKET 0 VOLTS 00% INSULATION LEVEL s Flexible tinned copper Flexible tinned copper with yellow polypropylene insulation
More information600 Volt SUPERSEAL Self-Repairing Low Voltage Utility Cables
Applications Secondary UD Power Cable, with aluminum conductors and a cross-linked polyethylene insulation that is formulated for a balance of flexibility and mechanical toughness. Superseal uses a patented
More informationMEDIUM VOLTAGE
WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent
More informationLV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments
ife? No S n K P r o ble m! No? aw a proven, rugged product for harsh environments No LV AIRGUARD LV AIRGUARD Low Voltage Cables for Harsh Environments FEATURES - No Knife? No Saw? No Problem! installation
More information14 AWG 2 AWG: 600 Volt
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.70 600V Type MC Metal Clad and Teck-Style Cables Overview Metal Clad Interlocked PVC Outer Jacket Teck-Style PVC Outer Jacket Introduction Polyester Wrap
More informationCOMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationOKONITE CABLES STOCK CATALOG In Stock for Immediate Delivery
Bulletin OSC OKONITE CABES STOCK CATAOG In Stock for Immediate Delivery THE OKONITE COMPANY 0 Hilltop Road, Ramsey, New Jersey 07 Phone.8.000 www.okonite.com INDEX Data Sheet Section:Sheet GOSSARY OF TERMS
More informationCIR (Crush & Impact Resistant) VFD Power Cable
37-2 CIRVFD CIR (Crush & Impact Resistant) VFD Power Cable Gexol Insulated Three Conductor 2kV Rated 90 C UL Listed as Type TC-ER Power Conductors (x3) Soft annealed flexible stranded tinned copper per
More information600 Volt SUPERFLEX XLP Low Voltage Utility Cables
Applications Secondary UD Power Cable, with aluminum conductors and a single-layer cross-linked polyethylene insulation that is formulated for a balance of flexibility and mechanical toughness. Specifications
More informationDLO Flexible Power Cable
Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable...................................... 2-3 n Type W Cables Type W 1/C Motor Lead Cable.................................... 4-5 Type W 2/C
More informationInstrumentation Cables
around a world of cables UL INSTRUMENTATION CABLES UL THHN CABLES UL THWN CABLES Instrumentation Cables INDEX Introduction Specialty Cables 300V & 00V Instrumentation Cable Types Certificates and Standards
More informationUnderground System Design TADP 547
Underground System Design TADP 547 Industry Standards, Specifications and Guides Presentation 6.4 Instructor: Frank Frentzas Industry Organizations Several professional organizations develop standards
More informationDOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES
DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES El Dorado, Arkansas Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology
More informationSIMpull THHN, it slips and slides - all with NoLube.
SOUTHWIRE S SIMpull THHN Southwire maintains its goal of revolutionizing the wire industry by providing its consumers with a product that is not only SIMpull but also requires NoLube. SIMpull THHN is a
More informationProduct Index. 1 Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products Power and Control Tray Cable Products 31 39
Product Index SECTION PAGES Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products 0 Power and Control Tray Cable Products 9 Armored Products 0 5 5 Merchandising 5 Technical Information
More informationConductors and Raceway Design
IEEE Southern Alberta Section, Industrial Applications and Power & Energy Chapter Technical Program Conductors and Raceway Design Blair Sackney, Southwire Canada George Morlidge SMIEEE, Fluor Canada May
More informationVFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS
VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS INDUSTRIAL VFD CABLES Index n Variable Frequency Drive (VFD) Power Cables Extra Flexible VFD Power Cable............... 2-3 Crush & Impact Resistant
More informationLow Voltage AIRGUARD. A proven, rugged product for harsh environments
Low Voltage AIRGUARD A proven, rugged product for harsh environments Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable
More informationINDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS
INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable................................ 2-3 n Type W Cables Type W 1/C
More informationDOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES
DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology cables like
More informationOver 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships
Tray Cable Our Commitment Our commitment to our customers is simple - we deliver even when others can t. As one of Canada s largest wire, cable and data communication distributors for over 35 years, Texcan
More informationMedium Voltage Power Cables
N2XSY 6/0, /20, /30 NA2XSY 6/0, /20, /30 N2XS2Y 6/0, /20, /30 NA2XS2Y 6/0, /20, /30 N2XS(F)2Y 6/0, /20, /30 NA2XS(F)2Y 6/0, /20, /30 N2XSEY 3 x 6/0 Medium Voltage Power Cables Photo: HELUKABEL Q 47 Medium
More informationEXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV
CABLE DESCRIPTION Single- or multi-phase electric cable for creating a weak external magnetic field,so as to obtain a cable wherein at last one of the conductors is assembled from two or more insulated
More informationSANS 1339:2010 Electric cables Cross-linked polyethylene (XLPE) insulated cables for rated voltages 3,8/6,6 kv to 19/33 kv
DRAFT SOUTH AFRICAN STANDARD (DSS): PUBLIC ENQUIRY STAGE Document number: 66/1339/4 Reference: SANS 1339 Date of circulation: 2009-12-08 Closing date: 2010-02-08 Number and title: SANS 1339:2010 Electric
More informationFault location on power cables. Fault location on power cables
Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 1. Introduction Fault location on communication and power cables
More informationVSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)
KSXCY Series... 72 MDXCY Series... 73 HDXCY Series... 74 FDXCY Series... 76 P: (09) 264 1000 www.firstflex.co.nz KSXCY High Performance Fixed Copper Tape VSD Cable Flexible Conductors for Fixed Applications
More informationCCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations
CCW Continuously Corrugated Welded Cable Armored Cable for Hazardous Locations CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the most comprehensive line
More informationKerman & Kavian Cable Industries ( KCI )
KCI Kerman & Kavian Cable Industries ( KCI ) KCI Cables for control and instrumentation circuits 150/250 V (300 V) According to of IEC 60092-376 (2003) Electrical installations in ships - Part 376: Kerman
More informationMV Power Cable Testing Training
MV Power Cable Testing Training Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq Since power cables are used
More informationNotes 3 Explanatory Information 4-10
Low Voltage Cables Section Three SECTION THREE - LOW VOLTAGE CABLES PAGE Notes 3 Explanatory Information 4-10 Construction 4 Current Ratings 5 Rating Factors 6 Voltage Drops 8 Selection Procedures 10 Minimum
More informationGO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry
GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry ADC is a proud Sustaining Member of the IMSA organization and is the largest manufacturer in
More information11-SDMS-03 REV. 02 SPECIFICATIONS FOR
11-SDMS-03 REV. 02 SPECIFICATIONS FOR XLPE INSULATED POWER CABLES FOR RATED VOLTAGES FROM 15 KV UP TO 36 KV (U m ) This specification is property of SEC and subject to change or modification without notice
More informationElectrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.
734A COAXIAL CABLE Application Intended for interconnection of transmission and switching systems equipment. Features UL listed as NEC Type CMR and CSA certified as Type CMR. NORDX/CDT 734A coaxial was
More informationCUSTOM DESIGN COAXIAL CABLES BY SICAB
CUSTOM DESIGN COAXIAL CABLES BY SICAB. COAX RG 58 C/U Application: Coaxial Cable 50 Ohm For indoor installation as well as in industrial areas in conduits and cable ducts, for transmission of high frequency
More informationFilled Solid ALPETH Cable
I. Exchange Cables Filled Solid ALPETH Cable REA/RUS PE-39 2.39.01 CONDUCTORS: Solid, annealed copper wires, in 2, 24, 22 and 19 AWG. INSULATION: Solid, high-density polyeylene or polypropylene in distinctive
More informationVFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE
VFD CABLES 0% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE Nexans AmerCable VFD CABLES Index Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable.... - 5 CIR VFD Power Cable... - 7 CIR Arctic
More informationA. Product Description: Stranded conductor insulated wire.
SECTION 16120CPPR CONDUCTORS AND CABLE PART 1 - GENERAL 1.1 SYSTEM DESCRIPTION A. Product Requirements: Provide products as follows: 1. All building wire shall be stranded copper (no aluminum wire). 2.
More informationENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 177 2012 Specification for Braided 75 Ω, Mini-Series Quad Shield Coaxial Cable for CMTS and SDI cables NOTICE
More informationSECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.
SECTION 26 05 19 PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents. 1.2 CONTRACTOR SUBMITTALS A. The
More informationP Low Voltage Catalogue Cables Australia Powering your Project
P +61 8 9367 8978 Low Voltage Catalogue Cables Australia Powering your Project CABLES AUSTRALIA PTY LTD LOW VOLTAGE CATALOGUE ABOUT US Cables Australia is a locally owned and operated distributor of high
More informationShielded Fire Alarm Cables
PLENUM Low-Smoke PVC JACKET UL TYPE FPLP/CMP/CL3P C(UL) CMP 300 VOLT Shielded Fire Alarm Cables Fire Alarm, Signal Monitor/Detection Audio or Control Circuits Description: Chart F, Page 41 Shielded Plenum
More informationTHHN12STGN500 THHN 12 STR Green 500
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com Catalog Number Manufacturer Description Weight per unit Product Category Features Conductor
More informationTHHN2BK2500 THHN 2 STR Black 2500
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com Catalog Number Manufacturer Description Weight per unit Product Category Features Conductor
More informationStandard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables
Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES ( Data Sheets ) 11 kv XLPE-Insulated Three-Core Underground Cables (3x240 mm 2 ) ADWEA/ADDC/AADC STANDARD : D-AAA-CAB-11-3Cx240
More informationSBCA Industry Standards Subcommittee. Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations
SBCA Industry Standards Subcommittee Document: SBCA Series 6 Recommended Practices Date of Issue: Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations
More informationCoated Dead-end NOMENCLATURE GENERAL RECOMMENDATIONS
NOMENCLATURE Crossover Marks: Indicate starting point for application. Gritted and Neoprene Dipped Legs: Grit is permanently embedded in a coating of neoprene. GENERAL RECOMMENDATIONS Coated Dead-ends:
More informationDescriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN12S0LBK500 THHN 12 Sol Black 500 Southwire Company Catalog Number Manufacturer Description Weight per unit Product
More informationDescriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN500BK500 THHN 500 STR Black 500 Southwire Company Catalog Number Manufacturer Description Weight per unit Product
More informationTHHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500 Southwire Company Catalog Number Manufacturer Description Weight per
More informationCanadian OSP Copper I-1. Table of Contents
Canadian OSP Copper Premises Copper Table of Contents CELFIL BJBB, BJAB, BJMB and BJTB................................. I-2 Canadian ALPETH BHBB, BHAB, BKMB and BKTB.................... I-4 SEALPAP BHBF,
More informationTHHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C)
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category THHN6WH500 THHN 6 STR White 500 Southwire Company
More informationEXCELLENT ELECTRICAL PERFORMANCES
50OHMS CORRUGATED COPPER TUBE COAXIAL CABLE PRODUCT INTRODUCTION 2 Hansen's manufacturing of wide-scope 50ohms corrugated copper coaxial Cable is the fruitful result of the engineers' diligent research
More informationModule 2 Unit 6, 7, 8
Module 2 Unit 6, 7, 8 1. What is the definition of an ideal conductor? Material that will carry the greatest current with the lowest temperature rise 2. How much does copper weigh compared to aluminum?
More informationJULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.
FOREWORD This Standard is intended to be used within and for Iranian Ministry of Petroleum (N.I.O.C, N.I.G.C, N.P.C., N.I.O.R.D.C. and other affiliate organizations and companies) and has been prepared
More informationHendrix Tap, Tie & Ground Wire
Hendrix Tap, Tie & Ground Wire MADE IN U.S.A. 53 Old Wilton Road Milford, NH 03055-3119 603-673-2040 www.marmonutility.com A Marmon Wire & Cable/Berkshire Hathaway Company Tap Wire Description Hendrix
More informationDetailed Specifications & Technical Data
Description: Series 11, 14 AWG solid.064" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond IV quad shield (60% and 40% coverage), PVC jacket Physical Characteristics
More informationHO7RN-F 450/750V BS EN Highly Flexible Rubber Cable
Rubber Insulation and Rubber Sheathed Application Range Heavy duty flexible cables for medium mechanical stress For dry and wet applications Can be used for domestic electric tools According to HD 516
More informationRepublic Wire Inc. Our Raw Materials Make A Quality Difference. Diversity Of Products Meets Customer Needs
Republic Wire Inc. began operations in Cincinnati, Ohio in January of 1982. Ron Rosenbeck, owner and president of RWI, has been in the copper industry since 1973. Republic Wire orginally manufactured top-quality
More information2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties
2. CONDUCTORS 2.1 Strand Types 2.1.1 Concentric Strand 7 2.1.2 Bunch Strand 7 2.1.3 Rope Strand 8 2.1.4 Sector Conductor 8 2.1.5 Segmental Conductor 8 2.1.6 Annular Conductor 8 2.1.7 Compact Strand 8 2.1.8
More informationSPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET
INDEPENDENT POWER TRANSMISSION OPERATOR S.A. TNPRD/ SUBSTATION SPECIFICATION & EQUIPMENT SECTION December 2016 SPECIFICATION 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION
More informationFieldLink MC at 20 x outer diameter Torsion
Power cable for permanent installation and flexible applications with low mechanical stress DIN VDE 0281 Part 1 / HD21.1S3 Conductor Stranded bare copper wire acc. to IEC 60228 Cl.5 and Cl. 6, insulation
More information6419X Conduit Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10
6419X Conduit Cable Application: Industrial and commercial wiring, these cables are intended for installation in trunking and conduit. They may also be used inside fixed, protected installations such as
More informationCCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS
CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS OCTOBER 2014 CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the most comprehensive
More informationPRELIMINARIES. Generators and loads are connected together through transmission lines transporting electric power from one place to another.
TRANSMISSION LINES PRELIMINARIES Generators and loads are connected together through transmission lines transporting electric power from one place to another. Transmission line must, therefore, take power
More informationn 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible
n 0% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible Nexans AmerCable VFD CABLES CABLES Index VFD Cables Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable...
More informationJCN cables. The. splice is an
Molded Rubber Splices 15kV 3M molded rubber QS and QS-II kits are inline splices made from specially formulated, peroxide-cured, EPDM rubbers to ensure a stable seal and a splice that will last the life
More informationGeneral Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables
Islamic Republic of Iran Vice Presidency for Strategic Planning and Supervision General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables NO: 452-1 Office
More informationExtremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488
ÖLFLEX TRAY II/TRAY II CY Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded ÖLFLEX TRAY II ÖLFLEX TRAY II CY Unshielded Construction : Finely stranded bare copper Jacket:
More informationMETAL CLAD WIRING SYSTEM
METAL CLAD WIRING SYSTEM The Preferred Cable for CLASS I, DIVISION 1 OR ZONE 1 Best Cable for PWM Circuits THE OKONITE COMPANY Ramsey, New Jersey 07446 METAL CLAD WIRING SYSTEM The Preferred Cable for
More informationGEXOL WORLD CLASS OIL & GAS CABLES
GEXOL WORLD CLASS OIL & GAS CABLES Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant
More informationWire Gauge Chart. Cigar Lighter 10 to 12. Dome Light 1. Radio 2 to 4. Gauges 0.7 to 1. Instrument Lights 1.5 to 3
Wire Gauge Chart Amp Capacity Total Length of Wire in Circuit from Power Supply to Accessory 12 Volt 6 Volt 10-ft 20-ft 30-ft 40-ft 50-ft 60-ft 70-ft 80-ft 90-ft 100-ft 1.0 0.5 18 ga 18 ga 18 ga 18 ga
More informationÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary
TRAY-RATED CABLE Quick Select Chart 48 TC 600/TC 600 S 50 Flexible Tray Cable with TC-ER for Easier Installations; Unshielded & Shielded TRAY II/TRAY II CY 52 Extremely Oil-Resistant & Flexible Tray Cable
More informationIMSA TRAFFIC SIGNAL CABLE
IMSA TRAFFIC SIGNAL CABLE A tradition of excellence... Exceptional Performance.. is a worldwide leader in the development, design, manufacture, marketing & distribution of wire and cable products. A Broad
More informationLow Voltage Splices, 1000 V or less
Low Splices, 000 V or less For installations from 20 V to kv, 3M offers several low voltage splice options, including 3M-developed cold shrink technology, heat shrink, resin and tape. 3M Low Splices are
More informationShip Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4
Wiking Ship Hybrid Cable Application Hybrid cable for shipboard applications DATA ELEMENT Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T
More informationEC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s
EC 200 EC200 - Rev. 3-23.06.11 Characteristic impedance 50 ± 2 Material copper wire Nominal capacity (pf/m) 80.5 Construction - Relative propagation velocity (%) 83 Diameter (mm) 1.05 Inductance (µh/m)
More informationCreating. There is one basic question every customer needs to address when creating custom
Wire and cable have a very deep history in industry, and remain indispensable for a wide variety of applications today. In our current digitized and online landscape, getting the best wire and cable is
More informationTECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)
TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm 2 + 80mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of, 3C x95mm 2 +
More informationTPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT
TPE-INSULATED CABLES Products TPE - Cables TPE-INSULATED CABLES 105 C O N T E N T S C O N T E N T S Page TPE single cores according to DIN 72551, type A 107 TPE single cores according to DIN 72551, type
More informationSECTION MEDIUM-VOLTAGE CABLES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 05 13 MEDIUM-VOLTAGE CABLES SPEC WRITER NOTE: Delete between //-----// if not applicable to project. Also delete any other item or paragraph not applicable in
More informationAIRGUARD CATALOG. Low and Medium Voltage Cable Products and Accessories
AIRGUARD CATALOG Low and Medium Voltage Cable Products and Accessories VISION We believe in the effective, efficient and sustainable supply of energy and information as a primary driver in the development
More informationAIRGUARD CATALOG. Low and Medium Voltage Cable Products and Accessories
AIRGUARD CATALOG Low and Medium Voltage Cable Products and Accessories VISION We believe in the effective, efficient and sustainable supply of energy and information as a primary driver in the development
More informationPower Cables and their Application
Power Cables and their Application Parti Materials Construction Criteria for Selection Project Planning Laying and Installation Accessories Measuring and Testing Editor: Lothar Heinhold 3rd revised edition,
More informationDate: / TECHNICAL SPECIFICATIONS FOR 11 KV XLPE INSULATED UNDERGROUND CABLES
1 Date:19.09.2013/08.01.2014 TECHNICAL SPECIFICATIONS FOR 11 KV XLPE INSULATED UNDERGROUND 1.0 SCOPE: CABLES 1.1 The scope of this specification covers the design, manufacture, stage inspection at works,
More informationXLPE CABLE (33KV) September Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED
XLPE CABLE (33KV) September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata 700091. CIN: U40101WB2007SGC113474;
More informationMedium Voltage YOUR ENERGY, OUR SYSTEMS, ANYWHERE
Medium Voltage YOUR ENERGY, OUR SYSTEMS, NYWHERE Contents Introduction 3 Cable Components 4 Cable Handling 7 Product Codes 8 Health, Safety and Environment 9 Exploded Cable View 11 Copper 1.9/3.3kV 12
More informationWIRE & CABLE FILS ET CÂBLES ALAMBRES Y CABLES. 63 Technical information. 64 Primary Wire. 66 Brake Cable & Portable Extension Cable
05 63 Technical information 64 Primary Wire 66 Brake Cable & Portable Extension Cable 67 SXL & Bonded Wire WIRE & CABLE FILS ET CÂBLES 68 Trailer Cable 70 Battery Cable 71 Welding Cable 72 Booster Cable
More information