5-46kV 3/C TRXLPE POWER CSA Medium Voltage Commercial & Industrial Cables

Size: px
Start display at page:

Download "5-46kV 3/C TRXLPE POWER CSA Medium Voltage Commercial & Industrial Cables"

Transcription

1 5-46kV 3/C TRXLPE POWER CSA Medium Voltage Commercial & Industrial Cables Description Three conductor cable with stranded copper or aluminum conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength VOLTALENE TRXLPE insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductor(s), overall binder tape, and overall PVC jacket. Specifications CSA- CSA C68.10 Ratings FT1-40 C Sunlight Resistant For continuous, 130 C emergency, 250 C short-circuit operation. Options - Strandseal - Super smooth conductor shield - EPROTENAX (EPR) insulation - Zero or three grounding conductor(s) - Colored Jackets - LLDPE, CPE or LSOH Jacket - Copper tape shield with 20% overlap - Mine Power Feeder (MP, MP-GC) - Lead Sheath or Armour Installation in Air Underground Wet Locations With Messenger Direct Buried in Air Dry Locations Industrial Design Parameters CONDUCTOR: Class B Compressed concentric strand aluminum alloy 1350 or compact concentric soft drawn annealed copper per ASTM. CONDUCTOR SHIELD: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. INSULATION: Natural high dielectric strength tree-retardant cross-linked polyethylene (TRXLPE) VOLTALENE insulation, exhibiting an optimum balance of mechanical and electrical properties, insuring resistance to treeing. INSULATION SHIELD: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. METALLIC SHIELD: Helically applied non-magnetic copper tape over the insulation shield with a maximum 15% gap. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w/red, 1C w/blue, and 1C w/black. ASSEMBLY: Phase identified shielded conductors cabled with fillers forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability. JACKET: Black, sunlight resistant, polyvinyl chloride (PVC) jacket tightly applied the binder tape. 1

2 5kV 3/C TRXLPE POWER CSA Diameter (mm) 5kV 100%/133% Copper Three Q4256ZC 4 AWG CU Q4456ZC 2 AWG CU Q4656ZC 1 AWG CU Q4856ZC 1/0 AWG CU Q4956ZC 2/0 AWG CU Q4A56ZC 3/0 AWG CU Q4B56ZC 4/0 AWG CU Q4C56ZC 250 MCM CU Q4D56ZC 350 MCM CU Q4E56ZC 500 MCM CU Q4F56XC 750 MCM CU Q4G56XC 1000 MCM CU Underground per 2011 NEC Table (C)(79): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(75): Single three-conductor per 2011 NEC Table (C)(71): Single three-conductor 2

3 5kV 3/C TRXLPE POWER CSA Diameter (mm) 5kV 100%/133% Aluminum Three Q4K56ZC 4 AWG AL Q4M56ZC 2 AWG AL Q4O56ZC 1 AWG AL Q4Q56ZC 1/0 AWG AL Q4R56ZC 2/0 AWG AL Q4S56ZC 3/0 AWG AL Q4T56ZC 4/0 AWG AL Q4U56ZC 250 MCM AL Q4V56ZC 350 MCM AL Q4W56ZC 500 MCM AL Q4X56ZC 750 MCM AL Q4Y56ZC 1000 MCM AL Underground per 2011 NEC Table (C)(80): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(76): Single three-conductor per 2011 NEC Table (C)(72): Single three-conductor 3

4 8kV 3/C TRXLPE POWER CSA Diameter (mm) 8kV 100% Copper Three Q5256ZC 4 AWG CU Q5456ZC 2 AWG CU Q5656ZC 1 AWG CU Q5856ZC 1/0 AWG CU Q5956ZC 2/0 AWG CU Q5A56ZC 3/0 AWG CU Q5B56ZC 4/0 AWG CU Q5C56ZC 250 MCM CU Q5D56ZC 350 MCM CU Q5E56ZC 500 MCM CU Q5F56XC 750 MCM CU Q5G56XC 1000 MCM CU kV 133% Copper Three Q6456ZC 2 AWG CU Q6656ZC 1 AWG CU Q6856ZC 1/0 AWG CU Q6956ZC 2/0 AWG CU Q6A56ZC 3/0 AWG CU Q6B56ZC 4/0 AWG CU Q6C56ZC 250 MCM CU Q6D56ZC 350 MCM CU Q6E56ZC 500 MCM CU Q6F56XC 750 MCM CU Q6G56XC 1000 MCM CU Underground per 2011 NEC Table (C)(79): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(75): Single three-conductor per 2011 NEC Table (C)(71): Single three-conductor 4

5 8kV 3/C TRXLPE POWER CSA Diameter (mm) 8kV 100% Aluminum Three Q5K56ZC 4 AWG AL Q5M56ZC 2 AWG AL Q5O56ZC 1 AWG AL Q5Q56ZC 1/0 AWG AL Q5R56ZC 2/0 AWG AL Q5S56ZC 3/0 AWG AL Q5T56ZC 4/0 AWG AL Q5U56ZC 250 MCM AL Q5V56ZC 350 MCM AL Q5W56ZC 500 MCM AL Q5X56ZC 750 MCM AL Q5Y56ZC 1000 MCM AL kV 133% Aluminum Three Q6M56ZC 2 AWG AL Q6O56ZC 1 AWG AL Q6Q56ZC 1/0 AWG AL Q6R56ZC 2/0 AWG AL Q6S56ZC 3/0 AWG AL Q6T56ZC 4/0 AWG AL Q6U56ZC 250 MCM AL Q6V56ZC 350 MCM AL Q6W56ZC 500 MCM AL Q6X56ZC 750 MCM AL Q6Y56ZC 1000 MCM AL Underground per 2011 NEC Table (C)(80): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(76): Single three-conductor per 2011 NEC Table (C)(72): Single three-conductor 5

6 15kV 3/C TRXLPE POWER CSA Diameter (mm) 15kV 100% Copper Three Q7456ZC 2 AWG CU Q7656ZC 1 AWG CU Q7856ZC 1/0 AWG CU Q7956ZC 2/0 AWG CU Q7A56ZC 3/0 AWG CU Q7B56ZC 4/0 AWG CU Q7C56ZC 250 MCM CU Q7D56ZC 350 MCM CU Q7E56ZC 500 MCM CU Q7F56XC 750 MCM CU Q7G56XC 1000 MCM CU kV 133% Copper Three Q8456ZC 2 AWG CU Q8656ZC 1 AWG CU Q8856ZC 1/0 AWG CU Q8956ZC 2/0 AWG CU Q8A56ZC 3/0 AWG CU Q8B56ZC 4/0 AWG CU Q8C56ZC 250 MCM CU Q8D56ZC 350 MCM CU Q8E56ZC 500 MCM CU Q8F56XC 750 MCM CU Q8G56XC 1000 MCM CU Underground per 2011 NEC Table (C)(79): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(75): Single three-conductor per 2011 NEC Table (C)(71): Single three-conductor 6

7 15kV 3/C TRXLPE POWER CSA Diameter (mm) 15kV 100% Aluminum Three Q7M56ZC 2 AWG AL Q7O56ZC 1 AWG AL Q7Q56ZC 1/0 AWG AL Q7R56ZC 2/0 AWG AL Q7S56ZC 3/0 AWG AL Q7T56ZC 4/0 AWG AL Q7U56ZC 250 MCM AL Q7V56ZC 350 MCM AL Q7W56ZC 500 MCM AL Q7X56ZC 750 MCM AL Q7Y56ZC 1000 MCM AL kV 133% Aluminum Three Q8M56ZC 2 AWG AL Q8O56ZC 1 AWG AL Q8Q56ZC 1/0 AWG AL Q8R56ZC 2/0 AWG AL Q8S56ZC 3/0 AWG AL Q8T56ZC 4/0 AWG AL Q8U56ZC 250 MCM AL Q8V56ZC 350 MCM AL Q8W56ZC 500 MCM AL Q8X56ZC 750 MCM AL Q8Y56ZC 1000 MCM AL Underground per 2011 NEC Table (C)(80): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(76): Single three-conductor per 2011 NEC Table (C)(72): Single three-conductor 7

8 25kV 3/C TRXLPE POWER CSA Diameter (mm) 25kV 100% Copper Three Q9656ZC 1 AWG CU Q9856ZC 1/0 AWG CU Q9956ZC 2/0 AWG CU Q9A56ZC 3/0 AWG CU Q9B56ZC 4/0 AWG CU Q9C56ZC 250 MCM CU Q9D56ZC 350 MCM CU Q9E56ZC 500 MCM CU Q9F56XC 750 MCM CU kV 133% Copper Three QA656ZC 1 AWG CU QA856ZC 1/0 AWG CU QA956ZC 2/0 AWG CU QAA56ZC 3/0 AWG CU QAB56ZC 4/0 AWG CU QAC56ZC 250 MCM CU QAD56ZC 350 MCM CU QAE56ZC 500 MCM CU QAF56XC 750 MCM CU Underground per 2011 NEC Table (C)(79): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(75): Single three-conductor per 2011 NEC Table (C)(71): Single three-conductor 8

9 25kV 3/C TRXLPE POWER CSA Diameter (mm) 25kV 100% Aluminum Three Q9O56ZC 1 AWG AL Q9Q56ZC 1/0 AWG AL Q9R56ZC 2/0 AWG AL Q9S56ZC 3/0 AWG AL Q9T56ZC 4/0 AWG AL Q9U56ZC 250 MCM AL Q9V56ZC 350 MCM AL Q9W56ZC 500 MCM AL Q9X56ZC 750 MCM AL Q9Y56ZC 1000 MCM AL kV 133% Aluminum Three QAO56ZC 1 AWG AL QAQ56ZC 1/0 AWG AL QAR56ZC 2/0 AWG AL QAS56ZC 3/0 AWG AL QAT56ZC 4/0 AWG AL QAU56ZC 250 MCM AL QAV56ZC 350 MCM AL QAW56ZC 500 MCM AL QAX56ZC 750 MCM AL Underground per 2011 NEC Table (C)(80): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(76): Single three-conductor per 2011 NEC Table (C)(72): Single three-conductor 9

10 28kV 3/C TRXLPE POWER CSA Diameter (mm) 28kV 100% Copper Three QV656ZC 1 AWG CU QV856ZC 1/0 AWG CU QV956ZC 2/0 AWG CU QVA56ZC 3/0 AWG CU QVB56ZC 4/0 AWG CU QVC56ZC 250 MCM CU QVD56ZC 350 MCM CU QVE56ZC 500 MCM CU QVF56XC 750 MCM CU kV 133% Copper Three QB656ZC 1 AWG CU QB856ZC 1/0 AWG CU QB956ZC 2/0 AWG CU QBA56ZC 3/0 AWG CU QBB56ZC 4/0 AWG CU QBC56ZC 250 MCM CU QBD56ZC 350 MCM CU QBE56ZC 500 MCM CU Underground per 2011 NEC Table (C)(79): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(75): Single three-conductor per 2011 NEC Table (C)(71): Single three-conductor 10

11 28kV 3/C TRXLPE POWER CSA Diameter (mm) 28kV 100% Aluminum Three QVO56ZC 1 AWG AL QVQ56ZC 1/0 AWG AL QVR56ZC 2/0 AWG AL QVS56ZC 3/0 AWG AL QVT56ZC 4/0 AWG AL QVU56ZC 250 MCM AL QVV56ZC 350 MCM AL QVW56ZC 500 MCM AL QVX56ZC 750 MCM AL QVY56ZC 1000 MCM AL kV 133% Aluminum Three QBO56ZC 1 AWG AL QBQ56ZC 1/0 AWG AL QBR56ZC 2/0 AWG AL QBS56ZC 3/0 AWG AL QBT56ZC 4/0 AWG AL QBU56ZC 250 MCM AL QBV56ZC 350 MCM AL QBW56ZC 500 MCM AL QBX56ZC 750 MCM AL Underground per 2011 NEC Table (C)(80): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(76): Single three-conductor per 2011 NEC Table (C)(72): Single three-conductor 11

12 35kV 3/C TRXLPE POWER CSA Diameter (mm) 35kV 100% Copper Three QB856ZC 1/0 AWG CU QB956ZC 2/0 AWG CU QBA56ZC 3/0 AWG CU QBB56ZC 4/0 AWG CU QBC56ZC 250 MCM CU QBD56ZC 350 MCM CU QBE56ZC 500 MCM CU kV 133% Copper Three QC856ZC 1/0 AWG CU QC956ZC 2/0 AWG CU QCA56ZC 3/0 AWG CU QCB56ZC 4/0 AWG CU QCC56ZC 250 MCM CU QCD56ZC 350 MCM CU QCE56ZC 500 MCM CU Underground per 2011 NEC Table (C)(79): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(75): Single three-conductor per 2011 NEC Table (C)(71): Single three-conductor 12

13 35kV 3/C TRXLPE POWER CSA Diameter (mm) 35kV 100% Aluminum Three QBQ56ZC 1/0 AWG AL QBR56ZC 2/0 AWG AL QBS56ZC 3/0 AWG AL QBT56ZC 4/0 AWG AL QBU56ZC 250 MCM AL QBV56ZC 350 MCM AL QBW56ZC 500 MCM AL QBX56ZC 750 MCM AL kV 133% Aluminum Three QCQ56ZC 1/0 AWG AL QCR56ZC 2/0 AWG AL QCS56ZC 3/0 AWG AL QCT56ZC 4/0 AWG AL QCU56ZC 250 MCM AL QCV56ZC 350 MCM AL QCW56ZC 500 MCM AL Underground per 2011 NEC Table (C)(80): Single three-conductor cable in plastic duct, 75cm depth of burial, conductor temperature, 20 C ambient temperature, earth RHO of -cm/watt, 100% load factor, and shields in Air per 2011 NEC Table (C)(76): Single three-conductor per 2011 NEC Table (C)(72): Single three-conductor PRYSMIAN - A Brand of The All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of. The information is believed correct at the time of issue. reserves the right to amend any specifications without notice. These specifications are not contractually valid unless authorized by. Issued June

POWER CSA. Jacket Black sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.

POWER CSA. Jacket Black sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape. 5-46kV 1/C TRXLPE July 2002 Description Design Parameters Options Single conductor cable with stranded copper or aluminum conductor, triple extruded insulation system consisting of a thermosetting semiconducting

More information

5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables

5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables 5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables Applications Three copper conductors cable, each with a semiconducting conductor shield, high dielectric strength VOLTALENE TRXLPE

More information

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables Applications Multiconductor cable with stranded copper conductors, extruded high dielectric strength cross-linked polyethylene (XLPE) insulation, Type XHHW-2, cabled with bare copper grounding conductors

More information

5-35kV 1/C TRXLE MV-90 POWER (wire shield) Medium Voltage Commercial & Industrial Cables

5-35kV 1/C TRXLE MV-90 POWER (wire shield) Medium Voltage Commercial & Industrial Cables 5-35kV 1/C TRXLE MV-90 POWER (wire shield) Medium Voltage Commercial & Industrial Cables Description Single conductor cable with stranded copper or aluminum conductor, triple extruded insulation system

More information

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded (CCW) Type Cables*)

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded (CCW) Type Cables*) Design Parameters Description Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX

More information

600 Volt MULTICONDUCTOR EPR MC Low Voltage Commercial & Industrial Cables

600 Volt MULTICONDUCTOR EPR MC Low Voltage Commercial & Industrial Cables Applications Multiconductor cable with stranded copper conductors, extruded high dielectric strength thermosetting EPR-based insulation, Type XHHW-2, cabled with bare copper grounding conductors and fillers,

More information

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded Type Cables*)

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded Type Cables*) Design Parameters Description Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX

More information

5-35kV 1/C EPR MV-105 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables

5-35kV 1/C EPR MV-105 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables 5-35kV 1/C EPR MV-105 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables Description Single conductor cable with stranded copper or aluminum conductor, triple extruded insulation system

More information

5-35kV 1/C TRXLE MV-90 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables

5-35kV 1/C TRXLE MV-90 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables 5-35kV 1/C TRXLE MV-90 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables Description Single conductor cable with stranded copper or aluminum conductor, triple extruded insulation system

More information

MV-105 Power. (Tape Shield) 5-35kV 1/C EPR. Design Parameters. Description. Options. Installations

MV-105 Power. (Tape Shield) 5-35kV 1/C EPR. Design Parameters. Description. Options. Installations 5-35kV MV-105 Power (Tape Shield) 20120124 Description Design Parameters Options Single conductor cable with stranded copper or aluminum conductor, triple extruded insulation system consisting of a thermosetting

More information

Addison Medium Voltage Cables

Addison Medium Voltage Cables Addison Medium Voltage Cables www.addison-cables.com www.addison-tech.com 1 Caledonian Medium Voltage Cables(ICEA) Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables CATALOG OF PRODUCTS Isolated Copper Wire THHN/MTW/THWN-2 600V, single conductor having flame-retardant and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material.

More information

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable Part Number: Drive Cable Armored Variable Frequency Drive Cable UL Type MC HL, 600V, 90 C rated - LEAD FREE Description 3 conductor with 3 ground wires, continuous corrugated and welded, impervious aluminum

More information

TIGER BRAND MINING CABLES

TIGER BRAND MINING CABLES TIGER BRAND MINING CABLES 5-kV TYPE SHD-GC & MP-GC -55 TYPE SHD-GC /C MOLD-CURED CPE JACKET 0 VOLTS 00% INSULATION LEVEL s Flexible tinned copper Flexible tinned copper with yellow polypropylene insulation

More information

600 Volt SUPERSEAL Self-Repairing Low Voltage Utility Cables

600 Volt SUPERSEAL Self-Repairing Low Voltage Utility Cables Applications Secondary UD Power Cable, with aluminum conductors and a cross-linked polyethylene insulation that is formulated for a balance of flexibility and mechanical toughness. Superseal uses a patented

More information

MEDIUM VOLTAGE

MEDIUM VOLTAGE WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent

More information

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments ife? No S n K P r o ble m! No? aw a proven, rugged product for harsh environments No LV AIRGUARD LV AIRGUARD Low Voltage Cables for Harsh Environments FEATURES - No Knife? No Saw? No Problem! installation

More information

14 AWG 2 AWG: 600 Volt

14 AWG 2 AWG: 600 Volt INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.70 600V Type MC Metal Clad and Teck-Style Cables Overview Metal Clad Interlocked PVC Outer Jacket Teck-Style PVC Outer Jacket Introduction Polyester Wrap

More information

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

OKONITE CABLES STOCK CATALOG In Stock for Immediate Delivery

OKONITE CABLES STOCK CATALOG In Stock for Immediate Delivery Bulletin OSC OKONITE CABES STOCK CATAOG In Stock for Immediate Delivery THE OKONITE COMPANY 0 Hilltop Road, Ramsey, New Jersey 07 Phone.8.000 www.okonite.com INDEX Data Sheet Section:Sheet GOSSARY OF TERMS

More information

CIR (Crush & Impact Resistant) VFD Power Cable

CIR (Crush & Impact Resistant) VFD Power Cable 37-2 CIRVFD CIR (Crush & Impact Resistant) VFD Power Cable Gexol Insulated Three Conductor 2kV Rated 90 C UL Listed as Type TC-ER Power Conductors (x3) Soft annealed flexible stranded tinned copper per

More information

600 Volt SUPERFLEX XLP Low Voltage Utility Cables

600 Volt SUPERFLEX XLP Low Voltage Utility Cables Applications Secondary UD Power Cable, with aluminum conductors and a single-layer cross-linked polyethylene insulation that is formulated for a balance of flexibility and mechanical toughness. Specifications

More information

DLO Flexible Power Cable

DLO Flexible Power Cable Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable...................................... 2-3 n Type W Cables Type W 1/C Motor Lead Cable.................................... 4-5 Type W 2/C

More information

Instrumentation Cables

Instrumentation Cables around a world of cables UL INSTRUMENTATION CABLES UL THHN CABLES UL THWN CABLES Instrumentation Cables INDEX Introduction Specialty Cables 300V & 00V Instrumentation Cable Types Certificates and Standards

More information

Underground System Design TADP 547

Underground System Design TADP 547 Underground System Design TADP 547 Industry Standards, Specifications and Guides Presentation 6.4 Instructor: Frank Frentzas Industry Organizations Several professional organizations develop standards

More information

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES El Dorado, Arkansas Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology

More information

SIMpull THHN, it slips and slides - all with NoLube.

SIMpull THHN, it slips and slides - all with NoLube. SOUTHWIRE S SIMpull THHN Southwire maintains its goal of revolutionizing the wire industry by providing its consumers with a product that is not only SIMpull but also requires NoLube. SIMpull THHN is a

More information

Product Index. 1 Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products Power and Control Tray Cable Products 31 39

Product Index. 1 Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products Power and Control Tray Cable Products 31 39 Product Index SECTION PAGES Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products 0 Power and Control Tray Cable Products 9 Armored Products 0 5 5 Merchandising 5 Technical Information

More information

Conductors and Raceway Design

Conductors and Raceway Design IEEE Southern Alberta Section, Industrial Applications and Power & Energy Chapter Technical Program Conductors and Raceway Design Blair Sackney, Southwire Canada George Morlidge SMIEEE, Fluor Canada May

More information

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS INDUSTRIAL VFD CABLES Index n Variable Frequency Drive (VFD) Power Cables Extra Flexible VFD Power Cable............... 2-3 Crush & Impact Resistant

More information

Low Voltage AIRGUARD. A proven, rugged product for harsh environments

Low Voltage AIRGUARD. A proven, rugged product for harsh environments Low Voltage AIRGUARD A proven, rugged product for harsh environments Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable

More information

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable................................ 2-3 n Type W Cables Type W 1/C

More information

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology cables like

More information

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships Tray Cable Our Commitment Our commitment to our customers is simple - we deliver even when others can t. As one of Canada s largest wire, cable and data communication distributors for over 35 years, Texcan

More information

Medium Voltage Power Cables

Medium Voltage Power Cables N2XSY 6/0, /20, /30 NA2XSY 6/0, /20, /30 N2XS2Y 6/0, /20, /30 NA2XS2Y 6/0, /20, /30 N2XS(F)2Y 6/0, /20, /30 NA2XS(F)2Y 6/0, /20, /30 N2XSEY 3 x 6/0 Medium Voltage Power Cables Photo: HELUKABEL Q 47 Medium

More information

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV CABLE DESCRIPTION Single- or multi-phase electric cable for creating a weak external magnetic field,so as to obtain a cable wherein at last one of the conductors is assembled from two or more insulated

More information

SANS 1339:2010 Electric cables Cross-linked polyethylene (XLPE) insulated cables for rated voltages 3,8/6,6 kv to 19/33 kv

SANS 1339:2010 Electric cables Cross-linked polyethylene (XLPE) insulated cables for rated voltages 3,8/6,6 kv to 19/33 kv DRAFT SOUTH AFRICAN STANDARD (DSS): PUBLIC ENQUIRY STAGE Document number: 66/1339/4 Reference: SANS 1339 Date of circulation: 2009-12-08 Closing date: 2010-02-08 Number and title: SANS 1339:2010 Electric

More information

Fault location on power cables. Fault location on power cables

Fault location on power cables. Fault location on power cables Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 1. Introduction Fault location on communication and power cables

More information

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09) KSXCY Series... 72 MDXCY Series... 73 HDXCY Series... 74 FDXCY Series... 76 P: (09) 264 1000 www.firstflex.co.nz KSXCY High Performance Fixed Copper Tape VSD Cable Flexible Conductors for Fixed Applications

More information

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations CCW Continuously Corrugated Welded Cable Armored Cable for Hazardous Locations CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the most comprehensive line

More information

Kerman & Kavian Cable Industries ( KCI )

Kerman & Kavian Cable Industries ( KCI ) KCI Kerman & Kavian Cable Industries ( KCI ) KCI Cables for control and instrumentation circuits 150/250 V (300 V) According to of IEC 60092-376 (2003) Electrical installations in ships - Part 376: Kerman

More information

MV Power Cable Testing Training

MV Power Cable Testing Training MV Power Cable Testing Training Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq Since power cables are used

More information

Notes 3 Explanatory Information 4-10

Notes 3 Explanatory Information 4-10 Low Voltage Cables Section Three SECTION THREE - LOW VOLTAGE CABLES PAGE Notes 3 Explanatory Information 4-10 Construction 4 Current Ratings 5 Rating Factors 6 Voltage Drops 8 Selection Procedures 10 Minimum

More information

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry ADC is a proud Sustaining Member of the IMSA organization and is the largest manufacturer in

More information

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

11-SDMS-03 REV. 02 SPECIFICATIONS FOR 11-SDMS-03 REV. 02 SPECIFICATIONS FOR XLPE INSULATED POWER CABLES FOR RATED VOLTAGES FROM 15 KV UP TO 36 KV (U m ) This specification is property of SEC and subject to change or modification without notice

More information

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a. 734A COAXIAL CABLE Application Intended for interconnection of transmission and switching systems equipment. Features UL listed as NEC Type CMR and CSA certified as Type CMR. NORDX/CDT 734A coaxial was

More information

CUSTOM DESIGN COAXIAL CABLES BY SICAB

CUSTOM DESIGN COAXIAL CABLES BY SICAB CUSTOM DESIGN COAXIAL CABLES BY SICAB. COAX RG 58 C/U Application: Coaxial Cable 50 Ohm For indoor installation as well as in industrial areas in conduits and cable ducts, for transmission of high frequency

More information

Filled Solid ALPETH Cable

Filled Solid ALPETH Cable I. Exchange Cables Filled Solid ALPETH Cable REA/RUS PE-39 2.39.01 CONDUCTORS: Solid, annealed copper wires, in 2, 24, 22 and 19 AWG. INSULATION: Solid, high-density polyeylene or polypropylene in distinctive

More information

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE VFD CABLES 0% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE Nexans AmerCable VFD CABLES Index Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable.... - 5 CIR VFD Power Cable... - 7 CIR Arctic

More information

A. Product Description: Stranded conductor insulated wire.

A. Product Description: Stranded conductor insulated wire. SECTION 16120CPPR CONDUCTORS AND CABLE PART 1 - GENERAL 1.1 SYSTEM DESCRIPTION A. Product Requirements: Provide products as follows: 1. All building wire shall be stranded copper (no aluminum wire). 2.

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 177 2012 Specification for Braided 75 Ω, Mini-Series Quad Shield Coaxial Cable for CMTS and SDI cables NOTICE

More information

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents. SECTION 26 05 19 PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents. 1.2 CONTRACTOR SUBMITTALS A. The

More information

P Low Voltage Catalogue Cables Australia Powering your Project

P Low Voltage Catalogue Cables Australia Powering your Project P +61 8 9367 8978 Low Voltage Catalogue Cables Australia Powering your Project CABLES AUSTRALIA PTY LTD LOW VOLTAGE CATALOGUE ABOUT US Cables Australia is a locally owned and operated distributor of high

More information

Shielded Fire Alarm Cables

Shielded Fire Alarm Cables PLENUM Low-Smoke PVC JACKET UL TYPE FPLP/CMP/CL3P C(UL) CMP 300 VOLT Shielded Fire Alarm Cables Fire Alarm, Signal Monitor/Detection Audio or Control Circuits Description: Chart F, Page 41 Shielded Plenum

More information

THHN12STGN500 THHN 12 STR Green 500

THHN12STGN500 THHN 12 STR Green 500 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com Catalog Number Manufacturer Description Weight per unit Product Category Features Conductor

More information

THHN2BK2500 THHN 2 STR Black 2500

THHN2BK2500 THHN 2 STR Black 2500 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com Catalog Number Manufacturer Description Weight per unit Product Category Features Conductor

More information

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES ( Data Sheets ) 11 kv XLPE-Insulated Three-Core Underground Cables (3x240 mm 2 ) ADWEA/ADDC/AADC STANDARD : D-AAA-CAB-11-3Cx240

More information

SBCA Industry Standards Subcommittee. Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations

SBCA Industry Standards Subcommittee. Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations SBCA Industry Standards Subcommittee Document: SBCA Series 6 Recommended Practices Date of Issue: Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations

More information

Coated Dead-end NOMENCLATURE GENERAL RECOMMENDATIONS

Coated Dead-end NOMENCLATURE GENERAL RECOMMENDATIONS NOMENCLATURE Crossover Marks: Indicate starting point for application. Gritted and Neoprene Dipped Legs: Grit is permanently embedded in a coating of neoprene. GENERAL RECOMMENDATIONS Coated Dead-ends:

More information

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN12S0LBK500 THHN 12 Sol Black 500 Southwire Company Catalog Number Manufacturer Description Weight per unit Product

More information

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN500BK500 THHN 500 STR Black 500 Southwire Company Catalog Number Manufacturer Description Weight per unit Product

More information

THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500

THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500 Southwire Company Catalog Number Manufacturer Description Weight per

More information

Canadian OSP Copper I-1. Table of Contents

Canadian OSP Copper I-1. Table of Contents Canadian OSP Copper Premises Copper Table of Contents CELFIL BJBB, BJAB, BJMB and BJTB................................. I-2 Canadian ALPETH BHBB, BHAB, BKMB and BKTB.................... I-4 SEALPAP BHBF,

More information

THHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C)

THHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C) 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category THHN6WH500 THHN 6 STR White 500 Southwire Company

More information

EXCELLENT ELECTRICAL PERFORMANCES

EXCELLENT ELECTRICAL PERFORMANCES 50OHMS CORRUGATED COPPER TUBE COAXIAL CABLE PRODUCT INTRODUCTION 2 Hansen's manufacturing of wide-scope 50ohms corrugated copper coaxial Cable is the fruitful result of the engineers' diligent research

More information

Module 2 Unit 6, 7, 8

Module 2 Unit 6, 7, 8 Module 2 Unit 6, 7, 8 1. What is the definition of an ideal conductor? Material that will carry the greatest current with the lowest temperature rise 2. How much does copper weigh compared to aluminum?

More information

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum. FOREWORD This Standard is intended to be used within and for Iranian Ministry of Petroleum (N.I.O.C, N.I.G.C, N.P.C., N.I.O.R.D.C. and other affiliate organizations and companies) and has been prepared

More information

Hendrix Tap, Tie & Ground Wire

Hendrix Tap, Tie & Ground Wire Hendrix Tap, Tie & Ground Wire MADE IN U.S.A. 53 Old Wilton Road Milford, NH 03055-3119 603-673-2040 www.marmonutility.com A Marmon Wire & Cable/Berkshire Hathaway Company Tap Wire Description Hendrix

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data Description: Series 11, 14 AWG solid.064" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond IV quad shield (60% and 40% coverage), PVC jacket Physical Characteristics

More information

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable Rubber Insulation and Rubber Sheathed Application Range Heavy duty flexible cables for medium mechanical stress For dry and wet applications Can be used for domestic electric tools According to HD 516

More information

Republic Wire Inc. Our Raw Materials Make A Quality Difference. Diversity Of Products Meets Customer Needs

Republic Wire Inc. Our Raw Materials Make A Quality Difference. Diversity Of Products Meets Customer Needs Republic Wire Inc. began operations in Cincinnati, Ohio in January of 1982. Ron Rosenbeck, owner and president of RWI, has been in the copper industry since 1973. Republic Wire orginally manufactured top-quality

More information

2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties

2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties 2. CONDUCTORS 2.1 Strand Types 2.1.1 Concentric Strand 7 2.1.2 Bunch Strand 7 2.1.3 Rope Strand 8 2.1.4 Sector Conductor 8 2.1.5 Segmental Conductor 8 2.1.6 Annular Conductor 8 2.1.7 Compact Strand 8 2.1.8

More information

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET INDEPENDENT POWER TRANSMISSION OPERATOR S.A. TNPRD/ SUBSTATION SPECIFICATION & EQUIPMENT SECTION December 2016 SPECIFICATION 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION

More information

FieldLink MC at 20 x outer diameter Torsion

FieldLink MC at 20 x outer diameter Torsion Power cable for permanent installation and flexible applications with low mechanical stress DIN VDE 0281 Part 1 / HD21.1S3 Conductor Stranded bare copper wire acc. to IEC 60228 Cl.5 and Cl. 6, insulation

More information

6419X Conduit Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

6419X Conduit Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10 6419X Conduit Cable Application: Industrial and commercial wiring, these cables are intended for installation in trunking and conduit. They may also be used inside fixed, protected installations such as

More information

CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS

CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS OCTOBER 2014 CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the most comprehensive

More information

PRELIMINARIES. Generators and loads are connected together through transmission lines transporting electric power from one place to another.

PRELIMINARIES. Generators and loads are connected together through transmission lines transporting electric power from one place to another. TRANSMISSION LINES PRELIMINARIES Generators and loads are connected together through transmission lines transporting electric power from one place to another. Transmission line must, therefore, take power

More information

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible n 0% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible Nexans AmerCable VFD CABLES CABLES Index VFD Cables Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable...

More information

JCN cables. The. splice is an

JCN cables. The. splice is an Molded Rubber Splices 15kV 3M molded rubber QS and QS-II kits are inline splices made from specially formulated, peroxide-cured, EPDM rubbers to ensure a stable seal and a splice that will last the life

More information

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables Islamic Republic of Iran Vice Presidency for Strategic Planning and Supervision General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables NO: 452-1 Office

More information

Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488

Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488 ÖLFLEX TRAY II/TRAY II CY Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded ÖLFLEX TRAY II ÖLFLEX TRAY II CY Unshielded Construction : Finely stranded bare copper Jacket:

More information

METAL CLAD WIRING SYSTEM

METAL CLAD WIRING SYSTEM METAL CLAD WIRING SYSTEM The Preferred Cable for CLASS I, DIVISION 1 OR ZONE 1 Best Cable for PWM Circuits THE OKONITE COMPANY Ramsey, New Jersey 07446 METAL CLAD WIRING SYSTEM The Preferred Cable for

More information

GEXOL WORLD CLASS OIL & GAS CABLES

GEXOL WORLD CLASS OIL & GAS CABLES GEXOL WORLD CLASS OIL & GAS CABLES Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant

More information

Wire Gauge Chart. Cigar Lighter 10 to 12. Dome Light 1. Radio 2 to 4. Gauges 0.7 to 1. Instrument Lights 1.5 to 3

Wire Gauge Chart. Cigar Lighter 10 to 12. Dome Light 1. Radio 2 to 4. Gauges 0.7 to 1. Instrument Lights 1.5 to 3 Wire Gauge Chart Amp Capacity Total Length of Wire in Circuit from Power Supply to Accessory 12 Volt 6 Volt 10-ft 20-ft 30-ft 40-ft 50-ft 60-ft 70-ft 80-ft 90-ft 100-ft 1.0 0.5 18 ga 18 ga 18 ga 18 ga

More information

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary TRAY-RATED CABLE Quick Select Chart 48 TC 600/TC 600 S 50 Flexible Tray Cable with TC-ER for Easier Installations; Unshielded & Shielded TRAY II/TRAY II CY 52 Extremely Oil-Resistant & Flexible Tray Cable

More information

IMSA TRAFFIC SIGNAL CABLE

IMSA TRAFFIC SIGNAL CABLE IMSA TRAFFIC SIGNAL CABLE A tradition of excellence... Exceptional Performance.. is a worldwide leader in the development, design, manufacture, marketing & distribution of wire and cable products. A Broad

More information

Low Voltage Splices, 1000 V or less

Low Voltage Splices, 1000 V or less Low Splices, 000 V or less For installations from 20 V to kv, 3M offers several low voltage splice options, including 3M-developed cold shrink technology, heat shrink, resin and tape. 3M Low Splices are

More information

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4 Wiking Ship Hybrid Cable Application Hybrid cable for shipboard applications DATA ELEMENT Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T

More information

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s EC 200 EC200 - Rev. 3-23.06.11 Characteristic impedance 50 ± 2 Material copper wire Nominal capacity (pf/m) 80.5 Construction - Relative propagation velocity (%) 83 Diameter (mm) 1.05 Inductance (µh/m)

More information

Creating. There is one basic question every customer needs to address when creating custom

Creating. There is one basic question every customer needs to address when creating custom Wire and cable have a very deep history in industry, and remain indispensable for a wide variety of applications today. In our current digitized and online landscape, getting the best wire and cable is

More information

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm 2 + 80mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of, 3C x95mm 2 +

More information

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT TPE-INSULATED CABLES Products TPE - Cables TPE-INSULATED CABLES 105 C O N T E N T S C O N T E N T S Page TPE single cores according to DIN 72551, type A 107 TPE single cores according to DIN 72551, type

More information

SECTION MEDIUM-VOLTAGE CABLES

SECTION MEDIUM-VOLTAGE CABLES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 05 13 MEDIUM-VOLTAGE CABLES SPEC WRITER NOTE: Delete between //-----// if not applicable to project. Also delete any other item or paragraph not applicable in

More information

AIRGUARD CATALOG. Low and Medium Voltage Cable Products and Accessories

AIRGUARD CATALOG. Low and Medium Voltage Cable Products and Accessories AIRGUARD CATALOG Low and Medium Voltage Cable Products and Accessories VISION We believe in the effective, efficient and sustainable supply of energy and information as a primary driver in the development

More information

AIRGUARD CATALOG. Low and Medium Voltage Cable Products and Accessories

AIRGUARD CATALOG. Low and Medium Voltage Cable Products and Accessories AIRGUARD CATALOG Low and Medium Voltage Cable Products and Accessories VISION We believe in the effective, efficient and sustainable supply of energy and information as a primary driver in the development

More information

Power Cables and their Application

Power Cables and their Application Power Cables and their Application Parti Materials Construction Criteria for Selection Project Planning Laying and Installation Accessories Measuring and Testing Editor: Lothar Heinhold 3rd revised edition,

More information

Date: / TECHNICAL SPECIFICATIONS FOR 11 KV XLPE INSULATED UNDERGROUND CABLES

Date: / TECHNICAL SPECIFICATIONS FOR 11 KV XLPE INSULATED UNDERGROUND CABLES 1 Date:19.09.2013/08.01.2014 TECHNICAL SPECIFICATIONS FOR 11 KV XLPE INSULATED UNDERGROUND 1.0 SCOPE: CABLES 1.1 The scope of this specification covers the design, manufacture, stage inspection at works,

More information

XLPE CABLE (33KV) September Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

XLPE CABLE (33KV) September Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED XLPE CABLE (33KV) September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata 700091. CIN: U40101WB2007SGC113474;

More information

Medium Voltage YOUR ENERGY, OUR SYSTEMS, ANYWHERE

Medium Voltage YOUR ENERGY, OUR SYSTEMS, ANYWHERE Medium Voltage YOUR ENERGY, OUR SYSTEMS, NYWHERE Contents Introduction 3 Cable Components 4 Cable Handling 7 Product Codes 8 Health, Safety and Environment 9 Exploded Cable View 11 Copper 1.9/3.3kV 12

More information

WIRE & CABLE FILS ET CÂBLES ALAMBRES Y CABLES. 63 Technical information. 64 Primary Wire. 66 Brake Cable & Portable Extension Cable

WIRE & CABLE FILS ET CÂBLES ALAMBRES Y CABLES. 63 Technical information. 64 Primary Wire. 66 Brake Cable & Portable Extension Cable 05 63 Technical information 64 Primary Wire 66 Brake Cable & Portable Extension Cable 67 SXL & Bonded Wire WIRE & CABLE FILS ET CÂBLES 68 Trailer Cable 70 Battery Cable 71 Welding Cable 72 Booster Cable

More information