5-35kV 1/C TRXLE MV-90 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables
|
|
- Kelly Welch
- 6 years ago
- Views:
Transcription
1 5-35kV 1/C TRXLE MV-90 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables Description Single conductor cable with stranded copper or aluminum conductor, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength VOLTALENE TRXLPE insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, and black PVC jacket. Specifications AEIC- AEIC CS8 ICEA- ICEA S ICEA- ICEA S UL- UL-1072 Ratings Type MV-90 Sunlight Resistant For 90 C continuous, 130 C emergency, 250 C short-circuit operation. Options - Strandseal - Compact stranded conductors - Super smooth conductor shield - Colored Jackets - LLDPE, CPE or LSOH Jacket - Oil Resistant jacket - Multiplex cables Installation Design Parameters CONDUCTOR: Class B Compressed concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM. CONDUCTOR SHIELD: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. INSULATION: Natural high dielectric strength VOLTALENE TRXLPE insulation, exhibiting an optimum balance of mechanical and electrical properties, insuring resistance to treeing. INSULATION SHIELD: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. METALLIC SHIELD: elically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. JACKET: Black, sunlight resistant, polyvinyl chloride (PVC) jacket tightly applied the copper tape. Conduit in Air Underground Duct With Messenger Dry Loctations Direct Buried Isolated in Air Wet Loctations Industrial 1
2 5kV 1/C TRXLPE MV-90 POWER (Tape Shield) Diameter (in) 5kV 100% Copper One Q42410A 4 AWG CU Q44410A 2 AWG CU Q46410A 1 AWG CU Q48410A 1/0 AWG CU Q49410A 2/0 AWG CU Q4A410A 3/0 AWG CU Q4B410A 4/0 AWG CU Q4C410A 250 MCM CU Q4D410A 350 MCM CU Q4E410A 500 MCM CU Q4F410A 750 MCM CU Q4G410A 1000 MCM CU kV 133% Copper One Q52410A 4 AWG CU Q54410A 2 AWG CU Q56410A 1 AWG CU Q58410A 1/0 AWG CU Q59410A 2/0 AWG CU Q5A410A 3/0 AWG CU Q5B410A 4/0 AWG CU Q5C410A 250 MCM CU Q5D410A 350 MCM CU Q5E410A 500 MCM CU Q5F410A 750 MCM CU Q5G410A 1000 MCM CU In Duct 2011 NEC Table (C)(77): Three single cables in Isolated in Air (2011 NEC Table (C)(69)): Single conductor In Cable Tray:per 2011 NEC (B)(2)(b), for single conductor ampacities shall not exceed the allowable ampacities stated in 2011 NEC Table (C)(69) (Copper), Isolated in Air values noted above. 2
3 5kV 1/C TRXLPE MV-90 POWER (Tape Shield) Diameter (in) 5kV 100% Aluminum One Q4K410A 4 AWG AL Q4M410A 2 AWG AL Q4O410A 1 AWG AL Q4Q410A 1/0 AWG AL Q4R410A 2/0 AWG AL Q4S410A 3/0 AWG AL Q4T410A 4/0 AWG AL Q4U410A 250 MCM AL Q4V410A 350 MCM AL Q4W410A 500 MCM AL Q4X410A 750 MCM AL Q4Y410A 1000 MCM AL kV 133% Aluminum One Q5K410A 4AWG AL Q5M410A 2AWG AL Q5O410A 1AWG AL Q5Q410A 1/0AWG AL Q5R410A 2/0AWG AL Q5S410A 3/0AWG AL Q5T410A 4/0AWG AL Q5U410A 250MCM AL Q5V410A 350MCM AL Q5W410A 500MCM AL Q5X410A 750MCM AL Q5Y410A 1000MCM AL In Duct (2011 NEC Table (C)(78): Three single cables in Isolated in Air (2011 NEC Table (C)(70): Single conductor In Cable Tray: per 2011 NEC (B)(2)(b), for single conductor ampacities shall not exceed the allowable ampacities stated in 2011 NEC Table (C)(70) (Aluminum), Isolated in Air values noted above. 3
4 8kV 1/C TRXLPE MV-90 POWER (Tape Shield) Diameter (in) 8kV 100% Copper One Q52410A 4 AWG CU Q54410A 2 AWG CU Q56410A 1 AWG CU Q58410A 1/0 AWG CU Q59410A 2/0 AWG CU Q5A410A 3/0 AWG CU Q5B410A 4/0 AWG CU Q5C410A 250 MCM CU Q5D410A 350 MCM CU Q5E410A 500 MCM CU Q5F410A 750 MCM CU Q5G410A 1000 MCM CU kV 133% Copper One Q64410A 2 AWG CU Q66410A 1 AWG CU Q68410A 1/0 AWG CU Q69410A 2/0 AWG CU Q6A410A 3/0 AWG CU Q6B410A 4/0 AWG CU Q6C410A 250 MCM CU Q6D410A 350 MCM CU Q6E410A 500 MCM CU Q6F410A 750 MCM CU Q6G410A 1000 MCM CU In Duct 2011 NEC Table (C)(77): Three single cables in Isolated in Air (2011 NEC Table (C)(69)): Single conductor In Cable Tray:per 2011 NEC (B)(2)(b), for single conductor ampacities shall not exceed the allowable ampacities stated in 2011 NEC Table (C)(69) (Copper), Isolated in Air values noted above. 4
5 8kV 1/C TRXLPE MV-90 POWER (Tape Shield) Diameter (in) 8kV 100% Aluminum One Q5K410A 4 AWG AL Q5M410A 2 AWG AL Q5O410A 1 AWG AL Q5Q410A 1/0 AWG AL Q5R410A 2/0 AWG AL Q5S410A 3/0 AWG AL Q5T410A 4/0 AWG AL Q5U410A 250 MCM AL Q5V410A 350 MCM AL Q5W410A 500 MCM AL Q5X410A 750 MCM AL Q5Y410A 1000 MCM AL kV 133% Aluminum One Q6M410A 2 AWG AL Q6O410A 1 AWG AL Q6Q410A 1/0 AWG AL Q6R410A 2/0 AWG AL Q6S410A 3/0 AWG AL Q6T410A 4/0 AWG AL Q6U410A 250 MCM AL Q6V410A 350 MCM AL Q6W410A 500 MCM AL Q6X410A 750 MCM AL Q6Y410A 1000 MCM AL In Duct (2011 NEC Table (C)(78): Three single cables in Isolated in Air (2011 NEC Table (C)(70): Single conductor In Cable Tray: per 2011 NEC (B)(2)(b), for single conductor ampacities shall not exceed the allowable ampacities stated in 2011 NEC Table (C)(70) (Aluminum), Isolated in Air values noted above. 5
6 15kV 1/C TRXLPE MV-90 POWER (Tape Shield) Diameter (in) 15kV 100% Copper One Q74410A 2 AWG CU Q76410A 1 AWG CU Q78410A 1/0 AWG CU Q79410A 2/0 AWG CU Q7A410A 3/0 AWG CU Q7B410A 4/0 AWG CU Q7C410A 250 MCM CU Q7D410A 350 MCM CU Q7E410A 500 MCM CU Q7F410A 750 MCM CU Q7G410A 1000 MCM CU kV 133% Copper One Q84410A 2 AWG CU Q86410A 1 AWG CU Q88410A 1/0 AWG CU Q89410A 2/0 AWG CU Q8A410A 3/0 AWG CU Q8B410A 4/0 AWG CU Q8C410A 250 MCM CU Q8D410A 350 MCM CU Q8E410A 500 MCM CU Q8F410A 750 MCM CU Q8G410A 1000 MCM CU In Duct 2011 NEC Table (C)(77): Three single cables in Isolated in Air (2011 NEC Table (C)(69)): Single conductor In Cable Tray:per 2011 NEC (B)(2)(b), for single conductor ampacities shall not exceed the allowable ampacities stated in 2011 NEC Table (C)(69) (Copper), Isolated in Air values noted above. 6
7 15kV 1/C TRXLPE MV-90 POWER (Tape Shield) Diameter (in) 15kV 100% Aluminum One Q7M410A 2 AWG AL Q7O410A 1 AWG AL Q7Q410A 1/0 AWG AL Q7R410A 2/0 AWG AL Q7S410A 3/0 AWG AL Q7T410A 4/0 AWG AL Q7U410A 250 MCM AL Q7V410A 350 MCM AL Q7W410A 500 MCM AL Q7X410A 750 MCM AL Q7Y410A 1000 MCM AL kV 133% Aluminum One Q8M410A 2 AWG AL Q8O410A 1 AWG AL Q8Q410A 1/0 AWG AL Q8R410A 2/0 AWG AL Q8S410A 3/0 AWG AL Q8T410A 4/0 AWG AL Q8U410A 250 MCM AL Q8V410A 350 MCM AL Q8W410A 500 MCM AL Q8X410A 750 MCM AL Q8Y410A 1000 MCM AL In Duct (2011 NEC Table (C)(78): Three single cables in Isolated in Air (2011 NEC Table (C)(70): Single conductor In Cable Tray: per 2011 NEC (B)(2)(b), for single conductor ampacities shall not exceed the allowable ampacities stated in 2011 NEC Table (C)(70) (Aluminum), Isolated in Air values noted above. 7
8 25kV 1/C TRXLPE MV-90 POWER (Tape Shield) Diameter (in) 25kV 100% Copper One Q96410A 1 AWG CU Q98410A 1/0 AWG CU Q99410A 2/0 AWG CU Q9A410A 3/0 AWG CU Q9B410A 4/0 AWG CU Q9C410A 250 MCM CU Q9D410A 350 MCM CU Q9E410A 500 MCM CU Q9F410A 750 MCM CU Q9G410A 1000 MCM CU kV 133% Copper One QB8410A 1/0 AWG CU QB9410A 2/0 AWG CU QBA410A 3/0 AWG CU QBB410A 4/0 AWG CU QBC410A 250 MCM CU QBD410A 350 MCM CU QBE410A 500 MCM CU QBF410A 750 MCM CU QBG410A 1000 MCM CU In Duct 2011 NEC Table (C)(77): Three single cables in Isolated in Air (2011 NEC Table (C)(69)): Single conductor In Cable Tray:per 2011 NEC (B)(2)(b), for single conductor ampacities shall not exceed the allowable ampacities stated in 2011 NEC Table (C)(69) (Copper), Isolated in Air values noted above. 8
9 25kV 1/C TRXLPE MV-90 POWER (Tape Shield) Diameter (in) 25kV 100% Aluminum One Q9O410A 1 AWG AL Q9Q410A 1/0 AWG AL Q9R410A 2/0 AWG AL Q9S410A 3/0 AWG AL Q9T410A 4/0 AWG AL Q9U410A 250 MCM AL Q9V410A 350 MCM AL Q9W410A 500 MCM AL Q9X410A 750 MCM AL Q9Y410A 1000 MCM AL kV 133% Aluminum One QBQ410A 1/0 AWG AL QBR410A 2/0 AWG AL QBS410A 3/0 AWG AL QBT410A 4/0 AWG AL QBU410A 250 MCM AL QBV410A 350 MCM AL QBW410A 500 MCM AL QBX410A 750 MCM AL QBY410A 1000 MCM AL In Duct (2011 NEC Table (C)(78): Three single cables in Isolated in Air (2011 NEC Table (C)(70): Single conductor In Cable Tray: per 2011 NEC (B)(2)(b), for single conductor ampacities shall not exceed the allowable ampacities stated in 2011 NEC Table (C)(70) (Aluminum), Isolated in Air values noted above. 9
10 35kV 1/C TRXLPE MV-90 POWER (Tape Shield) Diameter (in) 35kV 100% Copper One QB8410A 1/0 AWG CU QB9410A 2/0 AWG CU QBA410A 3/0 AWG CU QBB410A 4/0 AWG CU QBC410A 250 MCM CU QBD410A 350 MCM CU QBE410A 500 MCM CU QBF410A 750 MCM CU QBG410A 1000 MCM CU kV 133% Copper One QC8410A 1/0 AWG CU QC9410A 2/0 AWG CU QCA410A 3/0 AWG CU QCB410A 4/0 AWG CU QCC410A 250 MCM CU QCD410A 350 MCM CU QCE410A 500 MCM CU QCF410A 750 MCM CU QCG410A 1000 MCM CU In Duct 2011 NEC Table (C)(77): Three single cables in Isolated in Air (2011 NEC Table (C)(69)): Single conductor In Cable Tray:per 2011 NEC (B)(2)(b), for single conductor ampacities shall not exceed the allowable ampacities stated in 2011 NEC Table (C)(69) (Copper), Isolated in Air values noted above. 10
11 35kV 1/C TRXLPE MV-90 POWER (Tape Shield) Diameter (in) 35kV 100% Aluminum One QBQ410A 1/0 AWG AL QBR410A 2/0 AWG AL QBS410A 3/0 AWG AL QBT410A 4/0 AWG AL QBU410A 250 MCM AL QBV410A 350 MCM AL QBW410A 500 MCM AL QBX410A 750 MCM AL QBY410A 1000 MCM AL kV 133% Aluminum One QCQ410A 1/0 AWG AL QCR410A 2/0 AWG AL QCS410A 3/0 AWG AL QCT410A 4/0 AWG AL QCU410A 250 MCM AL QCV410A 350 MCM AL QCW410A 500 MCM AL QCX410A 750 MCM AL QCY410A 1000 MCM AL In Duct (2011 NEC Table (C)(78): Three single cables in Isolated in Air (2011 NEC Table (C)(70): Single conductor In Cable Tray: per 2011 NEC (B)(2)(b), for single conductor ampacities shall not exceed the allowable ampacities stated in 2011 NEC Table (C)(70) (Aluminum), Isolated in Air values noted above. PRYSMIAN - A Brand of The All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of. The information is believed correct at the time of issue. reserves the right to amend any specifications without notice. These specifications are not contractually valid unless authorized by. Issued July
5-35kV 1/C TRXLE MV-90 POWER (wire shield) Medium Voltage Commercial & Industrial Cables
5-35kV 1/C TRXLE MV-90 POWER (wire shield) Medium Voltage Commercial & Industrial Cables Description Single conductor cable with stranded copper or aluminum conductor, triple extruded insulation system
More information600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables
Applications Multiconductor cable with stranded copper conductors, extruded high dielectric strength cross-linked polyethylene (XLPE) insulation, Type XHHW-2, cabled with bare copper grounding conductors
More information5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables
5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables Applications Three copper conductors cable, each with a semiconducting conductor shield, high dielectric strength VOLTALENE TRXLPE
More information5-35kV 1/C EPR MV-105 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables
5-35kV 1/C EPR MV-105 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables Description Single conductor cable with stranded copper or aluminum conductor, triple extruded insulation system
More information5-46kV 3/C TRXLPE POWER CSA Medium Voltage Commercial & Industrial Cables
5-46kV 3/C TRXLPE POWER CSA Medium Voltage Commercial & Industrial Cables Description Three conductor cable with stranded copper or aluminum conductors, triple extruded insulation system consisting of
More information600 Volt MULTICONDUCTOR EPR MC Low Voltage Commercial & Industrial Cables
Applications Multiconductor cable with stranded copper conductors, extruded high dielectric strength thermosetting EPR-based insulation, Type XHHW-2, cabled with bare copper grounding conductors and fillers,
More information3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded Type Cables*)
Design Parameters Description Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX
More informationMV-105 Power. (Tape Shield) 5-35kV 1/C EPR. Design Parameters. Description. Options. Installations
5-35kV MV-105 Power (Tape Shield) 20120124 Description Design Parameters Options Single conductor cable with stranded copper or aluminum conductor, triple extruded insulation system consisting of a thermosetting
More information3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded (CCW) Type Cables*)
Design Parameters Description Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX
More informationPOWER CSA. Jacket Black sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.
5-46kV 1/C TRXLPE July 2002 Description Design Parameters Options Single conductor cable with stranded copper or aluminum conductor, triple extruded insulation system consisting of a thermosetting semiconducting
More information600 Volt SUPERFLEX XLP Low Voltage Utility Cables
Applications Secondary UD Power Cable, with aluminum conductors and a single-layer cross-linked polyethylene insulation that is formulated for a balance of flexibility and mechanical toughness. Specifications
More informationAddison Medium Voltage Cables
Addison Medium Voltage Cables www.addison-cables.com www.addison-tech.com 1 Caledonian Medium Voltage Cables(ICEA) Company Profile Caledonian. established in 1978.offers one of the most complete lines
More informationMEDIUM VOLTAGE
WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent
More informationLV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments
ife? No S n K P r o ble m! No? aw a proven, rugged product for harsh environments No LV AIRGUARD LV AIRGUARD Low Voltage Cables for Harsh Environments FEATURES - No Knife? No Saw? No Problem! installation
More informationCATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables
CATALOG OF PRODUCTS Isolated Copper Wire THHN/MTW/THWN-2 600V, single conductor having flame-retardant and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material.
More information600 Volt SUPERSEAL Self-Repairing Low Voltage Utility Cables
Applications Secondary UD Power Cable, with aluminum conductors and a cross-linked polyethylene insulation that is formulated for a balance of flexibility and mechanical toughness. Superseal uses a patented
More informationCORFLEX VFD CORFLEX VFD Part Number: Drive Cable
Part Number: Drive Cable Armored Variable Frequency Drive Cable UL Type MC HL, 600V, 90 C rated - LEAD FREE Description 3 conductor with 3 ground wires, continuous corrugated and welded, impervious aluminum
More informationOKONITE CABLES STOCK CATALOG In Stock for Immediate Delivery
Bulletin OSC OKONITE CABES STOCK CATAOG In Stock for Immediate Delivery THE OKONITE COMPANY 0 Hilltop Road, Ramsey, New Jersey 07 Phone.8.000 www.okonite.com INDEX Data Sheet Section:Sheet GOSSARY OF TERMS
More information14 AWG 2 AWG: 600 Volt
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.70 600V Type MC Metal Clad and Teck-Style Cables Overview Metal Clad Interlocked PVC Outer Jacket Teck-Style PVC Outer Jacket Introduction Polyester Wrap
More informationCOMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationSIMpull THHN, it slips and slides - all with NoLube.
SOUTHWIRE S SIMpull THHN Southwire maintains its goal of revolutionizing the wire industry by providing its consumers with a product that is not only SIMpull but also requires NoLube. SIMpull THHN is a
More informationDOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES
DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES El Dorado, Arkansas Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology
More informationCIR (Crush & Impact Resistant) VFD Power Cable
37-2 CIRVFD CIR (Crush & Impact Resistant) VFD Power Cable Gexol Insulated Three Conductor 2kV Rated 90 C UL Listed as Type TC-ER Power Conductors (x3) Soft annealed flexible stranded tinned copper per
More informationInstrumentation Cables
around a world of cables UL INSTRUMENTATION CABLES UL THHN CABLES UL THWN CABLES Instrumentation Cables INDEX Introduction Specialty Cables 300V & 00V Instrumentation Cable Types Certificates and Standards
More informationLow Voltage AIRGUARD. A proven, rugged product for harsh environments
Low Voltage AIRGUARD A proven, rugged product for harsh environments Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable
More informationTIGER BRAND MINING CABLES
TIGER BRAND MINING CABLES 5-kV TYPE SHD-GC & MP-GC -55 TYPE SHD-GC /C MOLD-CURED CPE JACKET 0 VOLTS 00% INSULATION LEVEL s Flexible tinned copper Flexible tinned copper with yellow polypropylene insulation
More informationUnderground System Design TADP 547
Underground System Design TADP 547 Industry Standards, Specifications and Guides Presentation 6.4 Instructor: Frank Frentzas Industry Organizations Several professional organizations develop standards
More informationTHHN12STGN500 THHN 12 STR Green 500
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com Catalog Number Manufacturer Description Weight per unit Product Category Features Conductor
More informationTHHN2BK2500 THHN 2 STR Black 2500
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com Catalog Number Manufacturer Description Weight per unit Product Category Features Conductor
More informationDescriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN500BK500 THHN 500 STR Black 500 Southwire Company Catalog Number Manufacturer Description Weight per unit Product
More informationDescriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN12S0LBK500 THHN 12 Sol Black 500 Southwire Company Catalog Number Manufacturer Description Weight per unit Product
More informationTHHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C)
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category THHN6WH500 THHN 6 STR White 500 Southwire Company
More informationTHHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500 Southwire Company Catalog Number Manufacturer Description Weight per
More informationDLO Flexible Power Cable
Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable...................................... 2-3 n Type W Cables Type W 1/C Motor Lead Cable.................................... 4-5 Type W 2/C
More informationProduct Index. 1 Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products Power and Control Tray Cable Products 31 39
Product Index SECTION PAGES Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products 0 Power and Control Tray Cable Products 9 Armored Products 0 5 5 Merchandising 5 Technical Information
More informationDOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES
DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology cables like
More informationVFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS
VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS INDUSTRIAL VFD CABLES Index n Variable Frequency Drive (VFD) Power Cables Extra Flexible VFD Power Cable............... 2-3 Crush & Impact Resistant
More informationSt. Monica Food Pantry Low Voltage (600V and less) Conductors and Cables sys-tek No
St. Monica Food Pantry 26 0519-1 ELECTRICAL WORK DIVISION 26 SECTION 260519 LOW VOLTAGE (600V AND LESS) PART 1. GENERAL 1.1 WIRES (SINGLE CONDUCTOR) AND CABLES (MULTI-CONDUCTOR ASSEMBLIES) USED FOR THE
More informationCCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations
CCW Continuously Corrugated Welded Cable Armored Cable for Hazardous Locations CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the most comprehensive line
More informationSECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.
SECTION 26 05 19 PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents. 1.2 CONTRACTOR SUBMITTALS A. The
More informationRepublic Wire Inc. Our Raw Materials Make A Quality Difference. Diversity Of Products Meets Customer Needs
Republic Wire Inc. began operations in Cincinnati, Ohio in January of 1982. Ron Rosenbeck, owner and president of RWI, has been in the copper industry since 1973. Republic Wire orginally manufactured top-quality
More informationIMSA TRAFFIC SIGNAL CABLE
IMSA TRAFFIC SIGNAL CABLE A tradition of excellence... Exceptional Performance.. is a worldwide leader in the development, design, manufacture, marketing & distribution of wire and cable products. A Broad
More informationINDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS
INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable................................ 2-3 n Type W Cables Type W 1/C
More informationStandards Update Notice (SUN) Issued: June 6, 2017
Standard Information Standard Number: UL 758 Standard Name: Standard for Safety for Appliance Wiring Material Standard Edition and Issue Date: 3 rd Edition Dated May 2, 2014 Date of Revisions: 2 nd Ed.
More information11-SDMS-03 REV. 02 SPECIFICATIONS FOR
11-SDMS-03 REV. 02 SPECIFICATIONS FOR XLPE INSULATED POWER CABLES FOR RATED VOLTAGES FROM 15 KV UP TO 36 KV (U m ) This specification is property of SEC and subject to change or modification without notice
More informationMV Power Cable Testing Training
MV Power Cable Testing Training Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq Since power cables are used
More informationSBCA Industry Standards Subcommittee. Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations
SBCA Industry Standards Subcommittee Document: SBCA Series 6 Recommended Practices Date of Issue: Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations
More informationElectrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.
734A COAXIAL CABLE Application Intended for interconnection of transmission and switching systems equipment. Features UL listed as NEC Type CMR and CSA certified as Type CMR. NORDX/CDT 734A coaxial was
More informationKerman & Kavian Cable Industries ( KCI )
KCI Kerman & Kavian Cable Industries ( KCI ) KCI Cables for control and instrumentation circuits 150/250 V (300 V) According to of IEC 60092-376 (2003) Electrical installations in ships - Part 376: Kerman
More information2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties
2. CONDUCTORS 2.1 Strand Types 2.1.1 Concentric Strand 7 2.1.2 Bunch Strand 7 2.1.3 Rope Strand 8 2.1.4 Sector Conductor 8 2.1.5 Segmental Conductor 8 2.1.6 Annular Conductor 8 2.1.7 Compact Strand 8 2.1.8
More informationVFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE
VFD CABLES 0% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE Nexans AmerCable VFD CABLES Index Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable.... - 5 CIR VFD Power Cable... - 7 CIR Arctic
More informationA. Product Description: Stranded conductor insulated wire.
SECTION 16120CPPR CONDUCTORS AND CABLE PART 1 - GENERAL 1.1 SYSTEM DESCRIPTION A. Product Requirements: Provide products as follows: 1. All building wire shall be stranded copper (no aluminum wire). 2.
More informationGO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry
GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry ADC is a proud Sustaining Member of the IMSA organization and is the largest manufacturer in
More informationGEXOL WORLD CLASS OIL & GAS CABLES
GEXOL WORLD CLASS OIL & GAS CABLES Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant
More informationExtremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488
ÖLFLEX TRAY II/TRAY II CY Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded ÖLFLEX TRAY II ÖLFLEX TRAY II CY Unshielded Construction : Finely stranded bare copper Jacket:
More informationENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 177 2012 Specification for Braided 75 Ω, Mini-Series Quad Shield Coaxial Cable for CMTS and SDI cables NOTICE
More informationHendrix Tap, Tie & Ground Wire
Hendrix Tap, Tie & Ground Wire MADE IN U.S.A. 53 Old Wilton Road Milford, NH 03055-3119 603-673-2040 www.marmonutility.com A Marmon Wire & Cable/Berkshire Hathaway Company Tap Wire Description Hendrix
More informationModule 2 Unit 6, 7, 8
Module 2 Unit 6, 7, 8 1. What is the definition of an ideal conductor? Material that will carry the greatest current with the lowest temperature rise 2. How much does copper weigh compared to aluminum?
More informationAIRGUARD CATALOG. Low and Medium Voltage Cable Products and Accessories
AIRGUARD CATALOG Low and Medium Voltage Cable Products and Accessories VISION We believe in the effective, efficient and sustainable supply of energy and information as a primary driver in the development
More informationAIRGUARD CATALOG. Low and Medium Voltage Cable Products and Accessories
AIRGUARD CATALOG Low and Medium Voltage Cable Products and Accessories VISION We believe in the effective, efficient and sustainable supply of energy and information as a primary driver in the development
More informationOver 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships
Tray Cable Our Commitment Our commitment to our customers is simple - we deliver even when others can t. As one of Canada s largest wire, cable and data communication distributors for over 35 years, Texcan
More informationCUSTOM DESIGN COAXIAL CABLES BY SICAB
CUSTOM DESIGN COAXIAL CABLES BY SICAB. COAX RG 58 C/U Application: Coaxial Cable 50 Ohm For indoor installation as well as in industrial areas in conduits and cable ducts, for transmission of high frequency
More informationJCN cables. The. splice is an
Molded Rubber Splices 15kV 3M molded rubber QS and QS-II kits are inline splices made from specially formulated, peroxide-cured, EPDM rubbers to ensure a stable seal and a splice that will last the life
More informationBX /2 Solid Ac/BX Aluminum Cable
3804 South Street 759647263, TX Nacogdoches Phone: 9365697941 Fax: 9365604685 BX102250 10/2 Solid Ac/BX Aluminum Cable Southwire Company Catalog Number Manufacturer Description Weight per unit Product
More informationConductors and Raceway Design
IEEE Southern Alberta Section, Industrial Applications and Power & Energy Chapter Technical Program Conductors and Raceway Design Blair Sackney, Southwire Canada George Morlidge SMIEEE, Fluor Canada May
More informationÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary
TRAY-RATED CABLE Quick Select Chart 48 TC 600/TC 600 S 50 Flexible Tray Cable with TC-ER for Easier Installations; Unshielded & Shielded TRAY II/TRAY II CY 52 Extremely Oil-Resistant & Flexible Tray Cable
More informationMedium Voltage Power Cables
N2XSY 6/0, /20, /30 NA2XSY 6/0, /20, /30 N2XS2Y 6/0, /20, /30 NA2XS2Y 6/0, /20, /30 N2XS(F)2Y 6/0, /20, /30 NA2XS(F)2Y 6/0, /20, /30 N2XSEY 3 x 6/0 Medium Voltage Power Cables Photo: HELUKABEL Q 47 Medium
More informationField Instrument Cable. Electrical Noise
Field Instrument Cable Electrical Noise 1 Electrical Noise Instrument Cables are Susceptible to 4 Types of Noise: Static Magnetic Cross-Talk Common Mode 2 Static Noise Static Noise is caused by an electric
More informationTRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 BONDING METHODS
1.0 SCOPE 2.0 BONDING METHODS 2.1 Introduction 2.2 Design 2.3 Single-Point Bonding 2.4 Cross Bonding 2.5 Sheath Sectionalizing Joints 2.6 Sheath Standing Voltage 2.7 Sheath Voltage at Through Fault 2.8
More informationSKINTOP ÖLFLEX CLICK & VFD CLICK FLEX. Products for Variable Frequency Drive Applications. ake the right connection
SKINTOP ÖLFLEX CLICK & VFD CLICK FLEX Products for Variable Frequency Drive Applications ake the right connection ake the right connection Connectivity solutions that keep you moving. Variable Frequency
More information6419X Conduit Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10
6419X Conduit Cable Application: Industrial and commercial wiring, these cables are intended for installation in trunking and conduit. They may also be used inside fixed, protected installations such as
More informationGround Clamps Cable Tray
commercial and industrial fittings: ing Fittings and Solderless Connectors Clamps Cable Tray Terminates ground wire to cable tray. For aluminum or copper conductors. 1 4 hex wrench tightens both tray and
More informationMulti-Paired Cable Product Finder
Multi-Paired Cable Product Finder Technical Information NO. STRAND TYPE C00 U......................, 0 0 C000 F........................ C0 FB....................... C FB....................... C0 F.......................
More informationAirport Cables & Connectors
Airport Cables & Connectors Aircraft Cable & Connector Products Descrip on 0 Hz Single Jacket No Contact Sec on 0 Hz Single Jacket With Replaceable Durable Hard Nose Contact Sec on 0 Hz Single Jacket -
More informationNotes 3 Explanatory Information 4-10
Low Voltage Cables Section Three SECTION THREE - LOW VOLTAGE CABLES PAGE Notes 3 Explanatory Information 4-10 Construction 4 Current Ratings 5 Rating Factors 6 Voltage Drops 8 Selection Procedures 10 Minimum
More informationn 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible
n 0% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible Nexans AmerCable VFD CABLES CABLES Index VFD Cables Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable...
More informationCoated Dead-end NOMENCLATURE GENERAL RECOMMENDATIONS
NOMENCLATURE Crossover Marks: Indicate starting point for application. Gritted and Neoprene Dipped Legs: Grit is permanently embedded in a coating of neoprene. GENERAL RECOMMENDATIONS Coated Dead-ends:
More informationFilled Solid ALPETH Cable
I. Exchange Cables Filled Solid ALPETH Cable REA/RUS PE-39 2.39.01 CONDUCTORS: Solid, annealed copper wires, in 2, 24, 22 and 19 AWG. INSULATION: Solid, high-density polyeylene or polypropylene in distinctive
More informationCCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS
CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS OCTOBER 2014 CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the most comprehensive
More informationMETAL CLAD WIRING SYSTEM
METAL CLAD WIRING SYSTEM The Preferred Cable for CLASS I, DIVISION 1 OR ZONE 1 Best Cable for PWM Circuits THE OKONITE COMPANY Ramsey, New Jersey 07446 METAL CLAD WIRING SYSTEM The Preferred Cable for
More informationDetailed Specifications & Technical Data
Description: 24 AWG stranded (7x32) TC conductor, Datalene insulation, pairs individually shielded with bonded Beldfoil with a drain wire and have numbered and color-coded PVC jackets, overall Beldfoil
More informationSECTION MEDIUM-VOLTAGE CABLES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 05 13 MEDIUM-VOLTAGE CABLES SPEC WRITER NOTE: Delete between //-----// if not applicable to project. Also delete any other item or paragraph not applicable in
More informationPRELIMINARIES. Generators and loads are connected together through transmission lines transporting electric power from one place to another.
TRANSMISSION LINES PRELIMINARIES Generators and loads are connected together through transmission lines transporting electric power from one place to another. Transmission line must, therefore, take power
More informationINTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.
INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn
More informationINTERMEDIATE METAL CONDUIT
PRODUCT GUIDE 08 CONDUIT PIPES CONDUIT FITTINGS FITTINGS FOR FLEXIBLE CONDUITS METALLIC ELECTRICAL BOXES AND COVERS CONDUIT BODIES WEATHERPROOF BOXES AND COVERS CHANNELS & SUPPORTS METAL ENCLOSURES CHANNELS
More informationDetailed Specifications & Technical Data
Description: Series 11, 14 AWG solid.064" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond IV quad shield (60% and 40% coverage), PVC jacket Physical Characteristics
More information3-10. General Quick Selection Introduction 3-Cordsets PannelConnect Safety. Connection. Network Media
16 AWG, STOOW PVC Heavy duty STOOW-A 16 AWG cable PVC jacket offers good oil and chemical 2-, 3-, 4-, 5-, and 6-pin configurations Contact Material Gold-plated palladium/nickel Cable Type Oil-resistant
More informationWire Gauge Chart. Cigar Lighter 10 to 12. Dome Light 1. Radio 2 to 4. Gauges 0.7 to 1. Instrument Lights 1.5 to 3
Wire Gauge Chart Amp Capacity Total Length of Wire in Circuit from Power Supply to Accessory 12 Volt 6 Volt 10-ft 20-ft 30-ft 40-ft 50-ft 60-ft 70-ft 80-ft 90-ft 100-ft 1.0 0.5 18 ga 18 ga 18 ga 18 ga
More informationShip Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4
Wiking Ship Hybrid Cable Application Hybrid cable for shipboard applications DATA ELEMENT Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T
More informationShielded Fire Alarm Cables
PLENUM Low-Smoke PVC JACKET UL TYPE FPLP/CMP/CL3P C(UL) CMP 300 VOLT Shielded Fire Alarm Cables Fire Alarm, Signal Monitor/Detection Audio or Control Circuits Description: Chart F, Page 41 Shielded Plenum
More informationFault location on power cables. Fault location on power cables
Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 1. Introduction Fault location on communication and power cables
More information25 mm 2 stranded 35 mm 2 flexible Aluminium cable
6 A multitude of cables and conductors of the most diverse types and versions are used to connect electrical and electronic components. The cables and conductors must be accurately prepared depending on
More informationTratos High Voltage cables
March 2013 Tratos High Voltage cables Cables for a moving world www.tratos.eu Introduction High Voltage Cables Tratos is an international manufacturer and supplier of High & Extra High Voltage cable up
More informationContinuous Flex Data Cable
1,! gti',',n Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA 080--Main Office: () 88-00-Outside Local Area: (800) 8-00-www.stevenengineering.com Continuous Flex Data Cable UNITRONIC
More informationElectrical Wiring: Commercial, Seventh Canadian Edition
Electrical Wiring Commercial Canadian 7th Edition Mullin SOLUTIONS MANUAL Full download at: https://testbankreal.com/download/electrical-wiring-commercialcanadian-7th-edition-mullin-solutions-manual/ Unit
More information3.1 Overview of ATCO Electric s URD System Design
Page: 3-1 3.0 URD DESIGN GUIDELINES 3.1 Overview of ATCO Electric s URD System Design ATCO Electric s design for distribution power supply to URD areas is a primary looped supply system. This is generically
More informationSECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION
SECTION 16715 COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION PART 1 - GENERAL 1.01 SECTION DESCRIPTION AND BASIC REQUIREMENTS A. The Electrical Power Distribution System provides power distribution from
More informationDETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, TWELVE INDIVIDUALLY SHIELDED PAIRS 22 (7 X 30) AWG
INCH-POUND MIL-DTL-49285/22B 27 March 2018 SUPERSEDING MIL DTL 49285/22A 1 March 2010 DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, TWELVE INDIVIDUALLY SHIELDED PAIRS 22 (7 X 30) AWG Inactive
More informationGeneral Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables
Islamic Republic of Iran Vice Presidency for Strategic Planning and Supervision General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables NO: 452-1 Office
More informationVSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)
KSXCY Series... 72 MDXCY Series... 73 HDXCY Series... 74 FDXCY Series... 76 P: (09) 264 1000 www.firstflex.co.nz KSXCY High Performance Fixed Copper Tape VSD Cable Flexible Conductors for Fixed Applications
More information