P Low Voltage Catalogue Cables Australia Powering your Project

Size: px
Start display at page:

Download "P Low Voltage Catalogue Cables Australia Powering your Project"

Transcription

1 P Low Voltage Catalogue Cables Australia Powering your Project

2 CABLES AUSTRALIA PTY LTD LOW VOLTAGE CATALOGUE ABOUT US Cables Australia is a locally owned and operated distributor of high quality cables and hardware for the electrical industry, offering a cost-effective alternative for your project requirements. With offices and warehousing facilities located in Shanghai, Guangzhou and Perth, Cables Australia is uniquely positioned to service Australia s resources, energy and heavy industrial sectors and understands the logistical and environmental challenges faced in this area. Cables Australia has successfully sourced and supplied a number of major projects including the Wickham town site underground power project (Rio Tinto), Cloudbreak and Christmas Creek Expansion Projects (Fortescue Metals Group), PNG Gas Conditioning Plant (Kentz) and Yurralyi Maya Power Station (IHI & ABB). OUR PRODUCTS Cables Australia can provide a comprehensive range of cabling, conductor, steel poles and powerline hardware, including speciality LV & HV cabling designed to meet your project requirements. Through our manufacturing partnerships, we source the highest quality products from internationally Lloyds accredited manufacturers who operate in compliance with the International Standard of Quality Management Systems. The strength of these relationships allow us to offer competitive pricing, reduced lead times and continuity of supply as well as technical support and design services. OUR CUSTOMERS We strive to build long standing customer relationships based on honesty and integrity. Our exacting quality standards will be measured by high levels of customer satisfaction and confidence in Cables Australia as a trusted and valued supplier. OUR MISSION It is the mission of Cables Australia to deliver the highest quality products manufactured to exacting quality control standards. We aim to deliver cost effective cabling and hardware solutions that meet project requirements and customer specifications, on site and on time. By training and retaining the best employees, Cables Australia will be able to deliver the highest level of customer service, while complying with all statutory and regulatory requirements. Page 2

3 CONTENTS ABOUT US... 2 Our Products... 2 Our Customers... 2 Our Mission... 2 OUR COMMITMENT TO QUALITY... 4 Australian Standards... 4 International Standards... 5 Cables Australia Capabilities... 5 SINGLE CORE... 6 PVC Earth... XLPE Earth PVC SDI XLPE/PVC Nylon Jacketed Armoured Armoured & Nylon Jacketed... Speciality Cables MULTI CORE PVC Multi-Core XLPE Multi-Core Multi-Core Nylon Cable Multi-Core Armoured Cable Multi-Core Armoured & Nylon Jacketed Cable GENERAL INFORMATION Page 3

4 CABLES AUSTRALIA PTY LTD OUR COMMITMENT TO QUALITY All our products are subject to exacting quality control procedures at every stage of manufacture, ensuring high performance in the field. Lloyds certification is available on all orders, providing even greater peace of mind. All products are manufactured to meet the requirements of the following International and Australian standards; Australian Standards AS 1531 s Bare overhead Aluminium and aluminium alloy. AS/NZS 26 Electric cables - Impregnated paper insulated - For working voltages up to and including 19/33 (36) kv. AS/NZS 11 s in insulated electric cables and flexible cords. AS/NZS Electric cables - Polymeric insulated - For working voltages /3.3 (3.6) kv up to and including 19/33 (36) kv. AS/NZS Electric cables - Polymeric insulated - For working voltages above 19/33 (36) kv up to and including 87/1 (1) kv. AS 1746 s - Bare overhead - Hard-drawn copper. AS/NZS 60.1 Electric cables - Cross-linked polyethylene insulated - Aerial bundled. - For working voltages up to and including 0.6/1()kV - Aluminium conductors. AS/NZS 60.2 Electric cables - Cross-linked polyethylene insulated - Aerial bundled. - For working voltages up to and including 0.6/1() kv - Copper conductors. AS/NZS 99.1 Electric cables - Aerial bundled - Polymeric insulated - Voltages 6./11(12) kv and 12.7/22(24) kv - Metallic screened. AS/NZS 99.2 Electric cables - Aerial bundled - Polymeric insulated - Voltages 6./11(12) kv and 12.7/22(24) kv - Non-metallic screened. AS 3607 s - Bare overhead, aluminium and aluminium alloy - Steel reinforced. AS/NZS 3675 s - Covered overhead - For working voltages 6./11(12) kv up to and including 19/33(36) kv. AS/NZS 00.1 Electric Cables Polymetric Insulated - For working voltages up to and including 0.6/1 (kv). AS/NZS 00.2 Electric cables - Polymeric insulated - For working voltages up to and including 4/7 V. AS/NZS 00.3 Electric cables - Polymeric insulated - Multicore control cables. AS/NZS Polyvinyl chloride (PVC) insulated cables of rated voltages up to and including 4/7 V - Flexible cables (cords). AS/NZS Rubber insulated cables - Rated voltage up to and including 4/7 V - Cords and flexible cables. Page 4

5 International Standards IEC s of insulated cables. IEC 602 Power cables with extruded insulation and their accessories for rated voltages from 1KV up to 30KV. IEC Calculation of the cyclic and emergency current rating of cables. IEC Calculation of thermally permissible short-circuit currents, taking into account non-adiabatic heating effects. IEC Amendment 1 - Short-circuit temperature limits of electric cables with rated voltages of 1 kv (Um = 1,2 kv) and 3 kv (Um = 3,6 kv). IEC Short-circuit temperature limits of electric cables with rated voltages from 6 kv (Um = 7,2 kv) up to 30 kv (Um = 36 kv). CABLES AUSTRALIA CAPABILITIES SALES SUPPORT Specification review & assistance Electrical Engineering & Design Services Local experience to suit your needs Design & implementation services Technical Support LOGISTICS SUPPORT Global Sourcing Expertise Shortest possible lead times Detailed production and shipping schedules allow your order to be tracked Flexible delivery & storage solutions QUALITY GUARANTEE Proof of Performance including Certificates of Compliance and Test Reports available Lloyds Certification All Cable Manufactured to meet stringent Australian and International Quality Standards Page 5

6 CABLES AUSTRALIA PTY LTD LOW VOLTAGE CATALOGUE SINGLE CORE 0.6/1kV PVC sheathed power cables are mostly used for buildings, industrial plants, gantry wiring, and road transport depots where not subject to mechanical damage. Page 6

7 CUSTOM DESIGN Our technical team can design an infinite number of highly engineered cables to suit your requirements while meeting relevant Australian, New Zealand and IEC quality standards. Page 7

8 CABLES AUSTRALIA PTY LTD LOW VOLTAGE CATALOGUE TECHNICAL DATA Current Carrying Capacity 1. Maximum conductor temperature: 90ºC 2. Environment temperature: 40ºC 3. Ground heat transfer resistance: Km/W 4. Depth of laying: m 5. Laying distance > cable diameter 6. Single circuit configuration Current Carrying Capacity in air Enviroment temperature (air) temperature ºC Current Carrying Capacity in soil Enviroment temperature (ground) temperature ºC Ground heat transfer resistance Ground heat transfer resistancepw = (K m/w) Voltage (kv) 0.6/ Page 8

9 MAX CONDUCTOR RESISTANCE Page DC Resistance CU (20ºC) AL AC Resistance CU (90ºC) AL

10 PVC EARTH Configuration : Plain annealed copper (CU) as specified in AS/NZS 11. : Colour: Polyvinyl Chloride Compound PVC V90 as specified in AS3808. Green & Yellow. Electrical Characteristics Rated Voltage: 0.6/1 kv Operating Temp: -ºC ~ 75ºC MAX 90ºC Max Short Circuit Temp: 0ºC for 5 seconds Minimum Bending Radius: 15x cable O.D during installation 12x cable O.D after installation NB. - The maximum conductor temperatures specified are based on the properties of the insulation material but in practice may need to be derated to take account of joints, terminations and environmental conditions. - The cables should not be flexed when either the ambient or cable temperature is below ºC. Standards AS/NZS00.1, AS/NZS11, AS/NZS /1kV CU/PVC V90 Cond. Outer 2 kg/km A A Page

11 XLPE EARTH Configuration : : Colour: Plain annealed copper (CU) as specified in AS/NZS 11. Cross-linked Polyethylene (XLPE) as specified in AS3808. Green & Yellow. Electrical Characteristics Rated Voltage: Operating Temp: Max Short Circuit Temp: Minimum Bending Radius: 0.6/1 kv -40ºC ~ 90ºC 2 ºC for 5 seconds 15x cable O.D during installation 12x cable O.D after installation NB. - The maximum conductor temperatures specified are based on the properties of the insulation material but in practice may need to be derated to take account of joints,terminations and environmental conditions. - The cables should not be flexed when either the ambient or cable temperature is below 0ºC. Standards AS/NZS00.1, AS/NZS11, AS/NZS /1kV CU/XLPE Cond. Outer 2 kg/km A A Page 11

12 PVC SDI Configuration : Inner : Outer : Sheath Colour: Plain annealed copper (CU) or plain aluminium (AL) as specified in AS/NZS 11. Polyvinyl Chloride PVC as specified in AS3808. Flame retardant Polyvinyl Chloride PVC V90 as specified in AS3808. Black or Orange. Electrical Characteristics Rated Voltage: Operating Temp: Max Short Circuit Temp: Minimum Bending Radius: 0.6/1 kv -ºC ~ 75ºC MAX 90ºC 0ºC for 5 seconds 15x cable O.D during installation 12x cable O.D after installation NB. - The maximum conductor temperatures specified are based on the properties of the insulation material but in practice may need to be derated to take account of joints,terminations and environmental conditions. - The cables should not be flexed when either the ambient or cable temperature is below 0ºC. Standards AS/NZS00.1, AS/NZS11, AS/NZS /1 kv CU/PVC/PVC/V90 Cond. Jacket Outer 2 kg/km A A Page 12

13 XLPE/PVC Configuration : Inner : Outer : Sheath Colour: Plain annealed copper (CU) or plain aluminium (AL) as specified in AS/NZS 11. Cross-linked Polyethylene (XLPE) as specified in AS3808. Flame retardant Polyvinyl Chloride PVC V90 as specified in AS3808. Black or Orange. Electrical Characteristics Rated Voltage: Operating Temp: Max Short Circuit Temp: Minimum Bending Radius: 0.6/1 kv -40ºC ~ 90ºC 2ºC for 5 seconds 15x cable O.D during installation 12x cable O.D after installation NB. - The maximum conductor temperatures specified are based on the properties of the insulation material but in practice may need to be derated to take account of joints,terminations and environmental conditions. - The cables should not be flexed when either the ambient or cable temperature is below 0ºC. Standards AS/NZS00.1, AS/NZS11, AS/NZS /1 kv CU/XLPE/PVC/V90 Cond. Jacket Outer 2 kg/km A A Page 13

14 NYLON JACKETED Configuration : Inner : Bedding: Extruded Layer: Outer : Sheath Colour: Plain annealed copper (CU) or plain aluminium (AL) as specified in AS/NZS 11. Cross-linked Polyethylene (XLPE) as specified in AS3808. Polyvinyl Chloride PVC as specified in AS3808. Extruded Polyamide Nylon Jacket. Flame retardant Polyvinyl Chloride PVC V90 as specified in AS3808. Black or Orange. Electrical Characteristics Rated Voltage: Operating Temp: Max Short Circuit Temp: Minimum Bending Radius: 0.6/1 kv -40ºC ~ 90ºC 2ºC for 5 seconds 18x cable O.D during installation 15x cable O.D after installation NB. - The maximum conductor temperatures specified are based on the properties of the insulation material but in practice may need to be derated to take account of joints,terminations and environmental conditions. - The cables should not be flexed when either the ambient or cable temperature is below 0ºC. Standards AS/NZS00.1, AS/NZS11, AS/NZS /1 kv CU/XLPE/PVC/NY/PVC/V90 Cond. Nylon Jacket Outer 2 kg/km A A Page 14

15 ARMOURED Configuration : Inner : Armour: Outer : Sheath Colour: Plain annealed copper (CU) or plain aluminium (AL) as specified in AS/NZS 11. Polyvinyl Chloride PVC as specified in AS3808. Single layer galvanized steel or stainless steel wires helically applied. Flame retardant Polyvinyl Chloride PVC V90 as specified in AS3808. Black or Orange. Electrical Characteristics Rated Voltage: Operating Temp: Max Short Circuit Temp: Minimum Bending Radius: 0.6/1 kv -ºC ~ 75ºC MAX 90ºC 0ºC for 5 seconds 18x cable O.D during installation 15x cable O.D after installation NB. - The maximum conductor temperatures specified are based on the properties of the insulation material but in practice may need to be derated to take account of joints,terminations and environmental conditions. - The cables should not be flexed when either the ambient or cable temperature is below 0ºC. Standards AS/NZS00.1, AS/NZS11, AS/NZS /1 kv CU/PVC/SSWA/PVC/V90 Cond. S/Steel Jacket Outer 2 kg/km A A Page 15

16 ARMOURED & NYLON JACKETED CABLE Configuration : Inner : Armour: Extruded Layer: Outer : Sheath Colour: Plain annealed copper (CU) or plain aluminium (AL) as specified in AS/NZS 11. Polyvinyl Chloride PVC as specified in AS3808. Single layer galvanized steel or stainless steel wires helically applied. Extruded Polyamide Nylon Jacket. Flame retardant Polyvinyl Chloride PVC V90 as specified in AS3808. Black or Orange. Electrical Characteristics Rated Voltage: Operating Temp: Max Short Circuit Temp: Minimum Bending Radius: 0.6/1 kv Operating Temp: Max Short Circuit Temp: Minimum Bending Radius: -ºC ~ 75ºC MAX 90ºC 0ºC for 5 seconds 18x cable O.D during installation 15x cable O.D after installation NB. - The maximum conductor temperatures specified are based on the properties of the insulation material but in practice may need to be derated to take account of joints, terminations and environmental conditions. - The cables should not be flexed when either the ambient or cable temperature is below 0ºC. Standards AS/NZS00.1, AS/NZS11, AS/NZS /1kV CU/PVC/SSWA/PVC/NY/PVC V90 Cond. S/Steel Nylon Jacket Outer 2 kg/km A A Page

17 SPECIALITY CABLES CABLE CONFIGURATION OPTIONS Phase : Stranded compacted plain aluminium or plain annealed copper conductor manufactured to AS/NZS 11. Phase Core: Semi-conductive conductor screen with cross linked polyethylene (XLPE) insulation and semi-conductive insulation screen to AS/NZS Metallic screen: Copper Wire Screen provides high conductivity for faulty current and can be manufactured to give different fault current characteristics. Armour: SWA single layer galvanised steel wires SSWA stainless steel wires AWA aluminium. Extruded Layer: Extruded Polyamide Nylon Jacket. Corrosion Protection: Double brass, copper or stainless steel tape offers an extra layer of protection if required. Bedding: Flame retardant 90ºC polyvinyl chloride (PVC). Sheathing: High density polyethylene (HDPE) or Continuous polyvinyl chloride compound PVC V90 as specified in AS3808. UV Protection 5V 90 (UV) Flame Retardant 5V-90 (FR) Low Smoke Zero Halogen / LS0H/5V-90 (FA). Page 17

18 CABLES AUSTRALIA PTY LTD LOW VOLTAGE CATALOGUE MULTI CORE 0.6/1kV PVC sheathed multi core power cables for mains, submains and subcircuits unenclosed, in conduit, buried direct or in underground ducts for buildings and industrial plants where not subject to mechanical damage. Page 18

19 CUSTOM DESIGN Our technical team can design an infinite number of highly engineered cables to suit your requirements while meeting relevant Australian, New Zealand and IEC quality standards. Page 19

20 PVC MULTI-CORE 0.6/1kV CU/PVC/PVC V90 Installation Suitable for installation indoor/outdoor, enclosed in conduit or in underground duct where not subject to mechanical force or damage. Additional protection is available for UV, low smoke zero halogen (LS0H) and Flame Retardant (FR) properties where required. Configuration : Plain annealed copper of the type specified in AS/NZS 11. : Polyvinyl chloride compound PVC as specified in AS3808. Laying-up: Cores are laid up with a right-hand direction of lay & non-hygroscopic filler where necessary. Sheath: Continuous polyvinyl chloride compound PVC V90 as specified in AS3808. Core Identification 2C + E Phase core: Red Neutral core: Black Earth Core: Green/Yellow 3C + E Phase core: Red, White, Blue Earth Core: Green/Yellow 4C + E Phase core: Red, White, Blue Neutral core: Black Earth Core: Green/Yellow Sheath: Orange (standard) or Black (optional ultraviolet radiation stabilized). Technical Data Rated Voltage: 0.6/1kV Operating Range: -ºC ~ 75ºC MAX 90ºC Max Short Circuit Temp: 0ºC for 5 seconds Minimum ambient temperature 0ºC, after installation and only when cable is in a fixed position. Minimum bending radius Stranded conductors: 9x cable O.D during installation 6x cable O.D after installation Compacted conductors: 12x cable O.D during installation 8x cable O.D after installation Standards AS/NZS00.1, AS/NZS11, AS/NZS3808 Plain annealed copper Non-hygroscopic filler 4C + E Polyvinyl Chloride Continuous polyvinyl chloride V90 Page 20

21 Jacket Cable Phase Earth A A kg/km C + E 3C + E A A kg/km A A kg/km C + E Page 21 Jacket Cable Jacket Cable Phase Earth Phase Earth

22 XLPE MULTI-CORE 0.6/1kV CU/XLPE/PVC V90 Installation Suitable for installation indoor/outdoor, enclosed in conduit or in underground duct where not subject to mechanical force or damage and/or where conditions of overload may occur. Additional protection is available for UV, low smoke zero halogen (LS0H) and Flame Retardant (FR) properties where required. Configuration : Pain annealed copper of the type specified in AS/NZS 11. : Cross-linked polyethylene compound XLPE as specified in AS3808. Laying-up: Cores are laid up with a right-hand direction of lay & non-hygroscopic filler where necessary. Sheath: Continuous polyvinyl chloride compound PVC V90 as specified in AS3808. Core Identification 2C + E Phase core: Red Neutral core: Black Earth Core: Green/Yellow 3C + E Phase core: Red, White, Blue Earth Core: Green/Yellow 4C + E Phase core: Red, White, Blue Neutral core: Black Earth Core: Green/Yellow Sheath: Orange (standard) or Black (optional ultraviolet radiation stabilized). Technical Data Rated Voltage: 0.6/1kV Operating Range: -40ºC ~ 90ºC MAX 90ºC Max Short Circuit Temp: 2ºC for 5 seconds Minimum ambient temperature 0ºC, after installation and only when cable is in a fixed position. Minimum bending radius Stranded conductors: 9x cable O.D during installation 6x cable O.D after installation Compacted conductors: 12x cable O.D during installation 8x cable O.D after installation Standards AS/NZS00.1, AS/NZS11, AS/NZS3808 Plain annealed copper Non-hygroscopic filler 4C + E Cross-linked polyethylene compound XLPE Continuous polyvinyl chloride V90 Page 22

23 A A kg/km C + E 3C + E A A kg/km A A C + E Page 23 Phase Earth Jacket Cable Phase Earth Jacket Cable Phase Earth Jacket Cable

24 MULTI-CORE NYLON CABLE 0.6/1kV CU/XLPE/PVC/NY/PVC V90 Installation Due to high mechanical strength and excellent thermal stability, the cable is suitable in areas where termites, insects and vermin resistance is required. Suitable for installation indoor/outdoor, enclosed in conduit or in underground duct and/or where conditions of overload may occur. Configuration : Plain annealed copper of the type specified in AS/NZS 11. : Cross-linked polyethylene compound XLPE as specified in AS3808. Laying-up: Cores are laid up together with a right-hand direction of lay, with nonhygroscopic filler where necessary. Extruded Layer: Extruded Polyamide Nylon Jacket. Sheath: Continuous polyvinyl chloride compound PVC V90 as specified in AS3808. Core Identification 2C + E Phase core: Red Neutral core: Black Earth Core: Green/Yellow 3C + E Phase core: Red, White, Blue Earth Core: Green/Yellow 4C + E Phase core: Red, White, Blue Neutral core: Black Earth Core: Green/Yellow Sheath: Orange (standard) or Black (optional ultraviolet radiation stabilized). Technical Data Rated Voltage: 0.6/1kV Operating Range: XLPE insulated, -40ºC ~ 90ºC Max Short Circuit Temp: 2ºC for 5 seconds Minimum ambient temperature 0ºC, after installation and only when cable is in a fixed position. Minimum bending radius Stranded conductors: 9x cable O.D during installation 6 x cable O.D after installation 4C + E Compacted conductors: 12x cable O.D during installation 8x cable O.D after installation Standards AS/NZS00.1, AS/NZS11, AS/NZS3808 Plain annealed copper Non-hygroscopic filler Cross-linked polyethylene compound XLPE Extruded Polyamide Nylon Continuous polyvinyl chloride V90 Page 24

25 A A kg/km C + E Nylon A A kg/km C + E A A kg/km C + E Jacket Cable Phase Earth Nylon Jacket Cable Phase Earth Nylon Jacket Cable Phase Earth

26 MULTI-CORE ARMOURED CABLE 0.6/1kV CU/XLPE/PVC/NY/PVC V90 Installation Suitable for installation indoor/outdoor/underwater, enclosed in conduit or in underground duct where mechanical damage and/or where conditions of overload may occur. Able to bear mechanical pressure and moderate pulling force. Configuration : Plain annealed copper of the type specified in AS/NZS 11. : Cross-linked polyethylene compound XLPE as specified in AS3808. Laying-up: Cores are laid up together with a right-hand direction of lay, with nonhygroscopic filler where necessary. Armour: SWA Galvanised Steel Wire Armoured SSWA Stainless Steel Wires Armoured AWA Aluminium Wire Armoured CWA Copper Wire Armoured Sheath: Continuous polyvinyl chloride compound PVC V90 as specified in AS3808. Core Identification 2C + E Phase core: Red Neutral core: Black Earth Core: Green/Yellow 3C + E Phase core: Red, White, Blue Earth Core: Green/Yellow 4C + E Phase core: Red, White, Blue Neutral core: Black Earth Core: Green/Yellow Sheath: Orange (standard) or Black (optional ultraviolet radiation stabilized). Technical Data Rated Voltage: 0.6/1kV Operating Range: -40ºC ~ 90ºC Max Short Circuit Temp: 2ºC for 5 seconds Minimum ambient temperature 0ºC, after installation and only when cable is in a fixed position. Minimum bending radius Stranded conductors: 9x cable O.D during installation 6x cable O.D after installation Plain annealed copper 4C + E Compacted conductors: 12x cable O.D during installation 8x cable O.D after installation Standards AS/NZS00.1, AS/NZS11, AS/NZS3808 Non-hygroscopic filler Cross-linked polyethylene compound XLPE Galvanised Steel Wire Armour Continuous polyvinyl chloride V90 Page 26

27 Jacket Cable Phase Earth A A kg/km C + E SWA A A kg/km C + E A A kg/km C + E Jacket Cable Phase Earth SWA Jacket Cable Phase Earth SWA

28 MULTI-CORE ARMOURED & NYLON JACKETED CABLE 0.6/1kV CU/XLPE/PVC/SWA/PVC/NY/PVC V90 Installation Suitable in areas where termites, insects and vermin resistance is required. Suitable for installation indoor/outdoor/ underwater, enclosed in conduit or in underground duct where mechanical damage may occur and/or where conditions of overload may occur. Able to bear mechanical pressure and moderate pulling force. Configuration : Plain annealed copper of the type specified in AS/NZS 11. : Cross-linked polyethylene compound XLPE as specified in AS3808. Laying-up: Cores are laid up together with a right-hand direction of lay, with nonhygroscopic filler where necessary. Armour: SWA Galvanised Steel Wire Armoured SSWA Stainless Steel Wires Armoured AWA Aluminium Wire Armoured CWA Copper Wire Armoured Extruded Layer: Extruded Polyamide Nylon Jacket. Sheath: Continuous polyvinyl chloride compound PVC V90 as specified in AS3808. Core Identification 2C + E Phase core: Red Neutral core: Black Earth Core: Green/Yellow 3C + E Phase core: Red, White, Blue Earth Core: Green/Yellow 4C + E Phase core: Red, White, Blue Neutral core: Black Earth Core: Green/Yellow Sheath: Orange (standard) or Black (optional ultraviolet radiation stabilized). Technical Data Rated Voltage: 0.6/1kV Operating Range: -40ºC ~ 90ºC Max Short Circuit Temp: 2ºC for 5 seconds Minimum ambient temperature 0ºC, after installation and only when cable is in a fixed position. Minimum bending radius Stranded conductors: 9x cable O.D during installation 6x cable O.D after installation Compacted conductors: 12x cable O.D during installation 8x cable O.D after installation Plain annealed copper Non-hygroscopic filler Cross-linked polyethylene compound XLPE 4C + E Standards AS/NZS00.1, AS/NZS11, AS/NZS3808 Galvanised Steel Wire Armour Extruded Polyamide Nylon Continuous polyvinyl chloride V90 Page 28

29 A A kg/km A A kg/km A A kg/km C + E 3C + E 4C + E Phase Earth Jacket Cable SWA Nylon Phase Earth Jacket Cable SWA Nylon Phase Earth Jacket Cable SWA Nylon

30 GENERAL INFORMATION CABLE SELECTION Refer to AS/NZS 8. for detailed information of cable selection. CURRENT RATING Current rating of a cable depends on: 1. Whether the cable is installed in air or ground, enclosed or unenclosed. 2. Installation environment, eg. ambient temperature, depth of laying, presence of other cables etc. 3. Operating temperatures for PVC insulated cables are 75ºC and XLPE insulated cables are 90ºC. 4. The type of overcurrent protective device is being used, appropriate derating factor: - for semi-enclosed (rewireable) fuses. - for fuses, e.g. AS 2005 series fuses, with I2 = x IN. - No derating is required for circuit breakers, e.g. AS/NZS 4898 circuit breakers, with I2 = 5 x IN. Where: I2 = conversional overcurrent fusing or tripping current. IN = nominal current of the fuse/circuit breaker. VOLTAGE DROP Wiring Rules stipulate a maximum voltage drop of 5% of the nominal voltage between the point of supply and any point in the installation when the conductors are carrying maximum demand. Voltage drops are based on: 1. Maximum conductor temperatures of 75 C, 90 C and 1 C as indicated. 2. Load power factor to give maximum voltage drop. 3. Single core cables are touching in trefoil or flat formation. 4. Supply frequency of Hz. An Equation to determine minimum required cable size due to voltage drop is: Vc = Vd x 00/I x L millivolts/ampere metre Where: Vc Millivolts drop/ampere metre as given in the tables. Vd Maximum permissible voltage drop in volts. I Current in Amperes. L Route length in metres. A Cable can now be selected such that Vc is equal to or less than calculated, and check that it will carry the current. ORDERING GUIDELINES Please supply the following information at the time of ordering: For specialty products, please supply list of specifications. Total length of cable required. Individual drum lengths required as well as drum preference (steel/wooden). Whether you require a certificate of compliance. Delivery requirements: standard delivery is EX Fremantle yard, however our logistics team can arrange delivery direct to project site or loading yard as project requirements dictate. Page 30

31 NOTES Whilst every care has been taken in the preparation of this publication, Cables Australia takes no responsibility for any errors and/or omissions. This technical manual is intended as a guide only and reference must be made by any person using this information to the appropriate Australian Standard and/or to local Electricity Supply Authority rulings. Copyright Cables Australia (ABN ) All rights reserved. Subject to change without notice. Page 31

32 PERTH SHANGHAI GUANGZHOU P F Suite, 0 Mill Point Rd, South Perth WA 6151

Notes 3 Explanatory Information 4-10

Notes 3 Explanatory Information 4-10 Low Voltage Cables Section Three SECTION THREE - LOW VOLTAGE CABLES PAGE Notes 3 Explanatory Information 4-10 Construction 4 Current Ratings 5 Rating Factors 6 Voltage Drops 8 Selection Procedures 10 Minimum

More information

Flexitime! Our flexible cables save you time and money.

Flexitime! Our flexible cables save you time and money. Flexitime! Our flexible cables save you time and money. We re flexible so you won t have to be. With our improved range of flexible cables we ve brought flexibility to a completely new level. From now

More information

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum. FOREWORD This Standard is intended to be used within and for Iranian Ministry of Petroleum (N.I.O.C, N.I.G.C, N.P.C., N.I.O.R.D.C. and other affiliate organizations and companies) and has been prepared

More information

Medium Voltage Power Cables

Medium Voltage Power Cables N2XSY 6/0, /20, /30 NA2XSY 6/0, /20, /30 N2XS2Y 6/0, /20, /30 NA2XS2Y 6/0, /20, /30 N2XS(F)2Y 6/0, /20, /30 NA2XS(F)2Y 6/0, /20, /30 N2XSEY 3 x 6/0 Medium Voltage Power Cables Photo: HELUKABEL Q 47 Medium

More information

Chapter 6. WIRING SYSTEMS Safe Electrical Design

Chapter 6. WIRING SYSTEMS Safe Electrical Design Chapter 6 WIRING SYSTEMS Safe Electrical Design Topic 6-3 CABLE SELECTION BASED ON CURRENT CARRYING CAPACITY REQUIREMENTS INSTALLATION CONDITIONS Current carrying capacity (CCC) is the maximum continuous

More information

Armoured Power and Control Cables to BS7917

Armoured Power and Control Cables to BS7917 1 Armoured Power and Control Cables to BS Fire Resistant, TAC. MGT. EPR. ZH. GSWB. SW, 00/00 V. Low Smoke Zero Halogen Application Armoured cables for fixed wiring in ships and offshore units where circuit

More information

Armoured Power and Control Cables Fire Resistant

Armoured Power and Control Cables Fire Resistant Armoured Power and Control Cables Fire Resistant Low Smoke Zero Halogen TAC. MGT. EPR. ZH. GSWB. SW, 00/00V Application Armoured cables for fixed wiring in ships and offshore units where circuit integrity

More information

Armoured Power and Control Cables to BS6883

Armoured Power and Control Cables to BS6883 Armoured Power and Control Cables to BS Low Smoke Zero Halogen Single-Core - T.A.C EPR, SW, TPBWB. SW 00/00 V Multicore - T.A.C EPR, SW, GSWB, SW 00/00 V Application Armoured cables for fixed wiring in

More information

Technical Specification. for 1.1 KV Copper Control Cable

Technical Specification. for 1.1 KV Copper Control Cable WEST BENGAL STATE ELECTRICITY DISTRIBUTION COMPANY LIMITED (A Govt. of West Bengal Enterprise) Office of the Chief Engineer, Procurement & Contracts Department Vidyut Bhavan, 4 th. floor, Bidhannagar,

More information

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09) KSXCY Series... 72 MDXCY Series... 73 HDXCY Series... 74 FDXCY Series... 76 P: (09) 264 1000 www.firstflex.co.nz KSXCY High Performance Fixed Copper Tape VSD Cable Flexible Conductors for Fixed Applications

More information

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV CABLE DESCRIPTION Single- or multi-phase electric cable for creating a weak external magnetic field,so as to obtain a cable wherein at last one of the conductors is assembled from two or more insulated

More information

Kerman & Kavian Cable Industries ( KCI )

Kerman & Kavian Cable Industries ( KCI ) KCI Kerman & Kavian Cable Industries ( KCI ) KCI Cables for control and instrumentation circuits 150/250 V (300 V) According to of IEC 60092-376 (2003) Electrical installations in ships - Part 376: Kerman

More information

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

11-SDMS-03 REV. 02 SPECIFICATIONS FOR 11-SDMS-03 REV. 02 SPECIFICATIONS FOR XLPE INSULATED POWER CABLES FOR RATED VOLTAGES FROM 15 KV UP TO 36 KV (U m ) This specification is property of SEC and subject to change or modification without notice

More information

CABLES AND WIRES

CABLES AND WIRES CABLES AND WIRES VOLTEX CATALOGUE 41 3 PVC GENERAL PURPOSE WIRE 1kV House Wire 600/1000V Cable Description High conductivity annealed stranded copper conductors to SANS 1411 Part 1. Insulated with PVC

More information

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY. INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn

More information

Fault location on power cables. Fault location on power cables

Fault location on power cables. Fault location on power cables Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 1. Introduction Fault location on communication and power cables

More information

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES ( Data Sheets ) 11 kv XLPE-Insulated Three-Core Underground Cables (3x240 mm 2 ) ADWEA/ADDC/AADC STANDARD : D-AAA-CAB-11-3Cx240

More information

Cables. Cables. Power. Fire Resistant WILSON CABLES PRIVATE LIMITED. Distributed By :

Cables. Cables. Power. Fire Resistant WILSON CABLES PRIVATE LIMITED. Distributed By : Power Cables Fire Resistant Cables Distributed By : WILSON CABLES PRIVATE LIMITED 142, Gul Circle, Jurong Industrial Estate, Singapore 629602 Tel : + 65 68617888 Fax : + 65 68617871 E-mail : exports@wilson-cables.com.sg

More information

6419X Conduit Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

6419X Conduit Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10 6419X Conduit Cable Application: Industrial and commercial wiring, these cables are intended for installation in trunking and conduit. They may also be used inside fixed, protected installations such as

More information

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET INDEPENDENT POWER TRANSMISSION OPERATOR S.A. TNPRD/ SUBSTATION SPECIFICATION & EQUIPMENT SECTION December 2016 SPECIFICATION 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION

More information

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured) WEST BENGAL STATE ELECTRICITY DISTRIBUTION COMPANY LIMITED (A Govt. of West Bengal Enterprise) Office of the Chief Engineer, Procurement & Contracts Department Vidyut Bhavan, 4 th. floor, Bidhannagar,

More information

Power Cables and their Application

Power Cables and their Application Power Cables and their Application Parti Materials Construction Criteria for Selection Project Planning Laying and Installation Accessories Measuring and Testing Editor: Lothar Heinhold 3rd revised edition,

More information

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES 2 TABLE OF CONTENTS SHIPBOARD CABLES 2 TELE-FONIKA KABLE 3 PRODUCTION POTENCIAL 5 SHIPBOARD POWER CABLES FlameBlocker KONS 0,6/1 kv 8 FlameBlocker

More information

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables Applications Multiconductor cable with stranded copper conductors, extruded high dielectric strength cross-linked polyethylene (XLPE) insulation, Type XHHW-2, cabled with bare copper grounding conductors

More information

Medium Voltage YOUR ENERGY, OUR SYSTEMS, ANYWHERE

Medium Voltage YOUR ENERGY, OUR SYSTEMS, ANYWHERE Medium Voltage YOUR ENERGY, OUR SYSTEMS, NYWHERE Contents Introduction 3 Cable Components 4 Cable Handling 7 Product Codes 8 Health, Safety and Environment 9 Exploded Cable View 11 Copper 1.9/3.3kV 12

More information

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables Islamic Republic of Iran Vice Presidency for Strategic Planning and Supervision General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables NO: 452-1 Office

More information

Technical cable guide

Technical cable guide Technical cable guide June 2015 One stop-shop for all your cable needs New Zealand edition DISCLAIMER Cables must be installed according to the requirements of AS/NZS 3000, the Wiring Rules and any supplementary

More information

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable Rubber Insulation and Rubber Sheathed Application Range Heavy duty flexible cables for medium mechanical stress For dry and wet applications Can be used for domestic electric tools According to HD 516

More information

CIR (Crush & Impact Resistant) VFD Power Cable

CIR (Crush & Impact Resistant) VFD Power Cable 37-2 CIRVFD CIR (Crush & Impact Resistant) VFD Power Cable Gexol Insulated Three Conductor 2kV Rated 90 C UL Listed as Type TC-ER Power Conductors (x3) Soft annealed flexible stranded tinned copper per

More information

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm 2 + 80mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of, 3C x95mm 2 +

More information

SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V

SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V LEDBURN CABLES IS AN INDEPENDENTLY OWNED CABLE DISTRIBUTOR. SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V Internal equipment wire. Also used in instrumentation panels of power switchgear. Suitable

More information

XLPE CABLE (33KV) September Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

XLPE CABLE (33KV) September Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED XLPE CABLE (33KV) September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata 700091. CIN: U40101WB2007SGC113474;

More information

Welding Cables Rubber Insulated

Welding Cables Rubber Insulated Welding Cables Rubber Insulated C 0 V Application Primary use is for the secondary (high current) connection to automatic or hand-held metal arc welding electrodes. May also be used for non-welding applications

More information

SUBMERSIBLE PUMP CABLES

SUBMERSIBLE PUMP CABLES 12 SUBMERSIBLE PUMP CABLES 1-450 / 750 V Termoplastic rubber, round orflat flexibe cable ACCORDING TO NF C -102 HD 22.4 S2 Water absorption tests: IEC 811.1.3 VDE 0472 Teil 2 NF C -026 HD 505-1-3 s1 Maximum

More information

Contents. Introduction 3 Cable Components 4 Cable Handling 8 Health, Safety and Environment 9 Quick Reference Guide 10 Underground Mining - Coal 12

Contents. Introduction 3 Cable Components 4 Cable Handling 8 Health, Safety and Environment 9 Quick Reference Guide 10 Underground Mining - Coal 12 Mining Cables Contents Introduction 3 Cable Components 4 Cable Handling 8 Health, Safety and Environment 9 Quick Reference Guide 10 Underground Mining - Coal 12 Type 241 and 241SF 14 Type 245SF 16 Type

More information

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES 1. Qualifying Requirement of AB Cable Manufacture/Supplier The manufacturer should have manufactured, successfully type tested

More information

Collection of standards in electronic format (PDF) 1. Copyright

Collection of standards in electronic format (PDF) 1. Copyright Collection of standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance

More information

EDS LV WAVEFORM MAINS CABLE RATINGS

EDS LV WAVEFORM MAINS CABLE RATINGS Document Number: EDS 02-0033 Network(s): Summary: ENGINEERING DESIGN STANDARD EDS 02-0033 LV WAVEFORM MAINS CABLE RATINGS EPN, LPN, SPN This standard details the technical and practical information required

More information

SANS 1339:2010 Electric cables Cross-linked polyethylene (XLPE) insulated cables for rated voltages 3,8/6,6 kv to 19/33 kv

SANS 1339:2010 Electric cables Cross-linked polyethylene (XLPE) insulated cables for rated voltages 3,8/6,6 kv to 19/33 kv DRAFT SOUTH AFRICAN STANDARD (DSS): PUBLIC ENQUIRY STAGE Document number: 66/1339/4 Reference: SANS 1339 Date of circulation: 2009-12-08 Closing date: 2010-02-08 Number and title: SANS 1339:2010 Electric

More information

NZQA registered unit standard version 5 Page 1 of 5. Demonstrate knowledge of electrical cables and accessories

NZQA registered unit standard version 5 Page 1 of 5. Demonstrate knowledge of electrical cables and accessories Page 1 of 5 Title Demonstrate knowledge of electrical cables and accessories Level 3 Credits 7 Purpose This unit standard is intended for people in the electrical and related trades, who need to be able

More information

Armoured Instrumentation Cables to BS6883

Armoured Instrumentation Cables to BS6883 Armoured Instrumentation Cables to BS Low Smoke Zero Halogen Pairs/Triples - Collectively Screened. TAC, EPR, SCRN, SW, GSWB, SW 0/0V Application Armoured control and instrumentation cables for fixed wiring

More information

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable Part Number: Drive Cable Armored Variable Frequency Drive Cable UL Type MC HL, 600V, 90 C rated - LEAD FREE Description 3 conductor with 3 ground wires, continuous corrugated and welded, impervious aluminum

More information

FLEXIBLE MULTI CORE CABLES

FLEXIBLE MULTI CORE CABLES FLEXIBLE MULTI FTM Series...22 MTSV Series...23 TW-T Series...24 PF Series...25 OD Series... 27 HD Series...28 MLG2 Multi Series...30 HO Plus Series...32 HR Series... 34 HRP Series...36 FX Series... 37

More information

MEDIUM VOLTAGE

MEDIUM VOLTAGE WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent

More information

Substation HV Cables. Document Number: 1-11-FR-07

Substation HV Cables. Document Number: 1-11-FR-07 Substation HV Cables Document Number: 1-11-FR-07 VERSION 1.0 June 2018 This functional requirements document is in line with the organisation's 1-11-ACS-07 Substation HV Cables Asset Class Strategy Intellectual

More information

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS OFFSHORE CABLES GENERAL CATALOGUE Offshore Cables technergy INTEGRATED CABLING SOLUTIONS TM 1 TEOF Offshore Cables INTEGRATED CABLING SOLUTIONS TM technergy Introduction Every offshore platform requires

More information

Instrumentation Cables

Instrumentation Cables around a world of cables UL INSTRUMENTATION CABLES UL THHN CABLES UL THWN CABLES Instrumentation Cables INDEX Introduction Specialty Cables 300V & 00V Instrumentation Cable Types Certificates and Standards

More information

Safety Warning. Installation

Safety Warning. Installation The NZ Handbook 2011 Edition Safety Warning Cables are insulated and sheathed with stable materials which may contain certain toxic substances including lead. Insulation and sheathing materials should

More information

VOLUME - 4 (GENERAL TECHNICAL SPECIFICATIONS)

VOLUME - 4 (GENERAL TECHNICAL SPECIFICATIONS) TENDER DOCUMENT NIT No. DLI/C&E/WI-665/535R FOR Tender for Supply of 3CX185 mm2, 11 KV (UE) grade, Power Cable for Augmentation of Raw Material Handling Receipt and Handling Facilities with new OHP Part

More information

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4 Page 1 of 12 STANDARD SPECIFICATION FOR INSTRUMENT CABLES DOCUMENT NO : 44-LK-5100-00/J.02/0014-A4 Rev No. Issue Date Pages Rev Description Prepared A 12-08-08 12 Issued for Comments / Approval By Checked

More information

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES FOR CABLE CARRIERS EDITION 09-2012 Durable, reliable, cost-effective

More information

CABLES AND BUSBAR SYSTEMS

CABLES AND BUSBAR SYSTEMS ELEC9713 Industrial and Commercial Power Systems CABLES AND BUSBAR SYSTEMS 1. Introduction Electrical power distribution in buildings and industrial sites is achieved primarily by use of cables or busbars.

More information

MV water-proof and water tree retardant power cable

MV water-proof and water tree retardant power cable MV water-proof and water tree retardant power cable 1 Standard GB/T16-8 1kV 35kV, IEC The products should be manufactured according to standard GB/T16-8 and also as per IEC, BS and HD as requested. 2 Application

More information

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables CATALOG OF PRODUCTS Isolated Copper Wire THHN/MTW/THWN-2 600V, single conductor having flame-retardant and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material.

More information

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships Tray Cable Our Commitment Our commitment to our customers is simple - we deliver even when others can t. As one of Canada s largest wire, cable and data communication distributors for over 35 years, Texcan

More information

ABOUT US ABOUT US 1 CRANE CABLES

ABOUT US ABOUT US 1 CRANE CABLES ABOUT US ABOUT US ÜNTEL KABLO, one of the leading cable manufacturers of Europe was established in 1972, Turkey. With almost 45 years of experience, it has been continuously developing and optimizing its

More information

Product information. Marine, Oil & Gas.

Product information. Marine, Oil & Gas. Product information Marine, Oil & Gas www.drakamog.com DRAKA Product information MOG 2010 Draka ShipLine range; the choice for reliability and flexibility For more than 100 years, Draka has met and exceeded

More information

Underground System Design TADP 547

Underground System Design TADP 547 Underground System Design TADP 547 Industry Standards, Specifications and Guides Presentation 6.4 Instructor: Frank Frentzas Industry Organizations Several professional organizations develop standards

More information

14 AWG 2 AWG: 600 Volt

14 AWG 2 AWG: 600 Volt INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.70 600V Type MC Metal Clad and Teck-Style Cables Overview Metal Clad Interlocked PVC Outer Jacket Teck-Style PVC Outer Jacket Introduction Polyester Wrap

More information

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications... Content page ❿! Applications... /2 ❿! Construction examples of special cables... /3-6 ❿! S 670 PUR hybrid field bus control cable, suitable for cable tracks UL/CSA... /7 ❿! S 671 PVC hybrid field bus control

More information

5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables

5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables 5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables Applications Three copper conductors cable, each with a semiconducting conductor shield, high dielectric strength VOLTALENE TRXLPE

More information

600 Volt MULTICONDUCTOR EPR MC Low Voltage Commercial & Industrial Cables

600 Volt MULTICONDUCTOR EPR MC Low Voltage Commercial & Industrial Cables Applications Multiconductor cable with stranded copper conductors, extruded high dielectric strength thermosetting EPR-based insulation, Type XHHW-2, cabled with bare copper grounding conductors and fillers,

More information

Tratos High Voltage cables

Tratos High Voltage cables March 2013 Tratos High Voltage cables Cables for a moving world www.tratos.eu Introduction High Voltage Cables Tratos is an international manufacturer and supplier of High & Extra High Voltage cable up

More information

EDS KV TRIPLEX CABLE RATING

EDS KV TRIPLEX CABLE RATING Document Number: EDS 02-0027 Network(s): Summary: EPN, LPN, SPN ENGINEERING DESIGN STANDARD EDS 02-0027 11KV TRIPLEX CABLE RATING This engineering design standard provides the cable ratings and important

More information

REPORT OF PERFORMANCE TIC

REPORT OF PERFORMANCE TIC REPORT OF PERFORMANCE TIC 1580-13 OBJECT TYPE Three-core power cable 18/30(36) kv, 3x500 mm2, 2XWY(P)-FR XLPE Rated voltage, U 0/U (U m) 18/30 (36) kv Conductor material Cu Conductor cross-section 3x500

More information

conductor Extruded Cross - Linked Polyethylene Insulated (XLPE) Power Cable Rated Voltage U 0 /U = 12/20 kv U 0 /U = 18/30 kv

conductor Extruded Cross - Linked Polyethylene Insulated (XLPE) Power Cable Rated Voltage U 0 /U = 12/20 kv U 0 /U = 18/30 kv Israel Electric Corporation Ltd. - Customer Division - National Network Unit Issued date: February 2018 THE ISRAEL ELECTRIC CORPORATION LTD. National Network Unit Specification No. NPS - 361 for Single

More information

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded (CCW) Type Cables*)

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded (CCW) Type Cables*) Design Parameters Description Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX

More information

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking A Technical data Special PVC control cables, adapted to DINVDE0 part3 Temperature range flexing -5 C ) to +0 C fixed installation

More information

H05Z-K / H07Z-K BS EN LSZH Wire

H05Z-K / H07Z-K BS EN LSZH Wire Application: In pipes or ducts and internal wiring of appliances with maximum operating temperatures of 90 C, and generally in areas (such as public and government buildings) where smoke and toxic fumes

More information

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations CCW Continuously Corrugated Welded Cable Armored Cable for Hazardous Locations CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the most comprehensive line

More information

Specification for pvc-insulated cables for electricity supply

Specification for pvc-insulated cables for electricity supply KENYA STANDARD KS 194: 2018 ICS 29.035.01 Specification for pvc-insulated cables for electricity supply (Third Revision, 2018) PUBLIC REVIEW DRAFT, FEBRUARY 2018 TECHNICAL COMMITTEE REPRESENTATION The

More information

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

K20 & L120 LSZH Armoured F/FTP Cat6 Cables K20 & L120 LSZH Armoured F/FTP Cat6 Cables The cables are designed for high speed data transmissions, and are suitable for installations in cable trays or on hooks. RATP CAT6-K20 (for K20 cable) FRANCE

More information

CABLE TRADE PRICE LIST TRADE PRICE LIST NO.TR21

CABLE TRADE PRICE LIST TRADE PRICE LIST NO.TR21 CABLE TRADE PRICE LIST TRADE PRICE LIST NO.TR21 12th March 2004 12th March 2004 TRADE PRICE LIST TR21 FOR PVC CABLES, LSOH CABLES AND FIRE RESISTANT CABLES These cables are sold subject to Pirelli s Standard

More information

Marine Cables General Catalogue

Marine Cables General Catalogue Marine Cables General Catalogue Marine Cables Special cables for civil and defence ship applications General catalogue Linking the Future As the worldwide leader in the cable industry, Prysmian Group believes

More information

Tri-Rated Flexible PVC Equipment Wire

Tri-Rated Flexible PVC Equipment Wire Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier

More information

SY CONTROL FLEXIBLE PVC INSULATED, BEDDED AND SHEATHED WITH GALVANISED STEEL BRAID

SY CONTROL FLEXIBLE PVC INSULATED, BEDDED AND SHEATHED WITH GALVANISED STEEL BRAID ISSUE DATE: 05/02/2016 PAGE: 1 Manufactured generally to BS EN 50525-2-11:2011 Plain Annealed Flexible Copper Conductors / PVC Insulated / PVC Bedding / GSWB (Galvanised Steel Wire Braid) / PVC Sheathed.

More information

TRAXLINE CABLES FOR MOTION

TRAXLINE CABLES FOR MOTION TRAXLINE CABLES FOR MOTION CONTINUOUS BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS TRAXLINE PRE-ASSEMBLED CABLES FOR CABLE CARRIERS EDITION 5-2016 Cost-effective, reliable, durable cables

More information

Chapter Seven. Under Ground Cables

Chapter Seven. Under Ground Cables Chapter Seven Under Ground Cables Construction of cables In the fig (7.1)below, shows the general construction of (3-condctor) cable The various part of cable are : 1- Core or conductor A cable may have

More information

EDS KV SINGLE CORE XLPE CABLES

EDS KV SINGLE CORE XLPE CABLES THIS IS AN UNCONTROLLED DOCUMENT, THE READER MUST CONFIRM ITS VALIDITY BEFORE USE Document Number: EDS 02-0034 ENGINEERING DESIGN STANDARD EDS 02-0034 33KV SINGLE CORE XLPE CABLES Network(s): EPN, LPN,

More information

TIGER BRAND MINING CABLES

TIGER BRAND MINING CABLES TIGER BRAND MINING CABLES 5-kV TYPE SHD-GC & MP-GC -55 TYPE SHD-GC /C MOLD-CURED CPE JACKET 0 VOLTS 00% INSULATION LEVEL s Flexible tinned copper Flexible tinned copper with yellow polypropylene insulation

More information

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS INDUSTRIAL VFD CABLES Index n Variable Frequency Drive (VFD) Power Cables Extra Flexible VFD Power Cable............... 2-3 Crush & Impact Resistant

More information

J S C E l e c t r o c a b l e W o r k s, K o l c h u g i n o. Product Catalogue

J S C E l e c t r o c a b l e W o r k s, K o l c h u g i n o. Product Catalogue J S C E l e c t r o c a b l e W o r k s, K o l c h u g i n o Product Catalogue P r o d u c t C a t a l o g u e c o n t e n t s Power Cables for Fixed Installation 7 Control cables 77 Cables for Alarm and

More information

Licensed Electricians Practical Assessment (LEP)

Licensed Electricians Practical Assessment (LEP) Licensed Electricians Practical Assessment (LEP) Surname: Given Names: Date: Time: Location: Assessment Time (includes reading and preparation time): At the end of this time you will be asked to stop.

More information

MarineLine YOZp 0,6/1 kv

MarineLine YOZp 0,6/1 kv Properties Application: Light, armoured, reduced low voltage power cables for power and lighting applications in all ship areas. Characteristics: Class 2 s Light, reduced Halogen free and low smoke, flame

More information

Low Voltage Cable Range. Edition 4 Brochure

Low Voltage Cable Range. Edition 4 Brochure Low Voltage Range Edition Brochure Revised 07/ 2012 COMPANY PROFILE Aberdare s, a member of the Powertech Group, is a leading African manufacturer of cables and electrical accessories, with seven manufacturing

More information

Sizing conductors and selecting protection devices

Sizing conductors and selecting protection devices Sizing conductors and selecting protection devices 04 POWER GUIDE 2009 / BOOK 04 INTRO Careful selection of the sizes of the conductors in wiring systems and the characteristics of protection devices will

More information

Addison Medium Voltage Cables

Addison Medium Voltage Cables Addison Medium Voltage Cables www.addison-cables.com www.addison-tech.com 1 Caledonian Medium Voltage Cables(ICEA) Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

15 years of experience

15 years of experience Wires and Cables 15 years of experience APS supplies standard and special copper and fiber optic cables based on its 15 years of experience in the sector, 8 of which in designing and manufacturing. Since

More information

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc. ()TSCGEWOEU TEAX TTS-LWL 3,6/6 kv: Application Flexible medium voltage reeling cable with integrated fibre-optics for the combined transmission of energy and data, for application under high mechanical

More information

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded Type Cables*)

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded Type Cables*) Design Parameters Description Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX

More information

Tests on Extruded Cables

Tests on Extruded Cables Tests on Extruded Cables Pierre Argaut Chairman of CIGRE SC B1 October 26 th, 2011 At least, once in your life, you have heard these words: Development Tests Long-term Tests Prequalification Tests Extension

More information

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø Automated Stacking Cranes (ASC) Ship To Shore Container Cranes (STS) Rubber Tyre Gantry (RTG)

More information

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments ife? No S n K P r o ble m! No? aw a proven, rugged product for harsh environments No LV AIRGUARD LV AIRGUARD Low Voltage Cables for Harsh Environments FEATURES - No Knife? No Saw? No Problem! installation

More information

CUSTOM DESIGN COAXIAL CABLES BY SICAB

CUSTOM DESIGN COAXIAL CABLES BY SICAB CUSTOM DESIGN COAXIAL CABLES BY SICAB. COAX RG 58 C/U Application: Coaxial Cable 50 Ohm For indoor installation as well as in industrial areas in conduits and cable ducts, for transmission of high frequency

More information

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION) 012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 8051 Fax: +94 11 232 5387 CONTENTS Page 1.0

More information

GEXOL WORLD CLASS OIL & GAS CABLES

GEXOL WORLD CLASS OIL & GAS CABLES GEXOL WORLD CLASS OIL & GAS CABLES Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant

More information

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. For more information please call 1-800-Belden1 See Put-ups and Colors Description:

More information

FLAME RETARDANT INSTRUMENTATION CABLE. Application Standard

FLAME RETARDANT INSTRUMENTATION CABLE. Application Standard FLAME RETARDANT INSTRUMENTATION CABLE Designation 150/250V TTY, FA-TTY, 150/250V TTYC, FA-TTYC, 150/250V TTYCY, FA-TTYCY 250V TTYC - Design guide : JIS C 3410(2010) - Flameretardant : IEC 60332-1 : IEC

More information

5-46kV 3/C TRXLPE POWER CSA Medium Voltage Commercial & Industrial Cables

5-46kV 3/C TRXLPE POWER CSA Medium Voltage Commercial & Industrial Cables 5-46kV 3/C TRXLPE POWER CSA Medium Voltage Commercial & Industrial Cables Description Three conductor cable with stranded copper or aluminum conductors, triple extruded insulation system consisting of

More information

POLYIMIDE INSULATED WIRES AND CABLES, LOW FREQUENCY, 600V, -200 TO +200 C BASED ON TYPE SPL. ESCC Detail Specification No.

POLYIMIDE INSULATED WIRES AND CABLES, LOW FREQUENCY, 600V, -200 TO +200 C BASED ON TYPE SPL. ESCC Detail Specification No. Page 1 of 23 POLYIMIDE INSULATED WIRES AND CABLES, LOW FREQUENCY, 600V, -200 TO +200 C BASED ON TYPE SPL ESCC Detail Specification Issue 3 May 2013 Document Custodian: European Space Agency see https://escies.org

More information