Gladiator G1 Series. Microwave Waveguide Information. Data Sheet. Overview. A Higher Level of Performance. Beam Blockage Detection
|
|
- Charleen Goodwin
- 6 years ago
- Views:
Transcription
1 Higher Level of Performance Data Sheet Gladiator G1 Series Microwave Waveguide Information eam lockage Detection For more information, please visit >
2 G1R or G1S Waveguide oncept M-WG01 M-WG11 1 Waveguides M-WG10-L=xxx *where xxx = System with Waveguide length extensions of pipe in for mm remote mounting / signal transmission. 1 Waveguides can be used for difficult to access areas or to isolate the electronics from high temperature or non-compatible processes M-WG1 M-WG02 Safe / accessible / hazard free area M-WG0 M-WG1 Non accessible / High temperature / Hazard area G1R or G1S Safe / accessible / hazard free area M-WG01 M-WG11 1 M-WG10-L=xxx *where xxx = length of pipe in mm Non accessible / High temperature / Hazard area M-WG1 M-WG02 M-WG0 M-WG1 2
3 Waveguides with Process Seals Waveguides with windowed weldment / coupling process seals System with Waveguide extensions for remote mounting / signal transmission. Waveguides can be used for difficult to access areas or to isolate the electronics from high temperature or non-compatible processes 1 Process Process 1 Pictured system: M2-W-SS (1) G1R Weldment / coupling (2) G1S with UHMW window 5 5 () Qty2 of M-WG01 () Qty2 of M-WG-L=xx (5) 1 Qty2 of M-WG0 2 2 eramic windows for high temperature applications Process Process 5 5 Pictured system: (1) G1R (2) G1S () Qty2 of M-WG01 () Qty2 of M-WG02 (5) Qty2 of M-WG-0 M16 Weldment with ceramic window
4 accessible / / ture temperature Example / / Setup rd area Example Waveguide setup with exploded parts M-WG0 ( horn) with M-WG1 ( teflon window) can be swapped with M-0 (1-1/2 horn) with M-WG12 (2 teflon plug). 1 G1 unit 0-L=xxx x = pipe in mm Locking nut (included with G1 unit) M-WG01 Threaded connecter connects unit to pipe. M-WG11 Locking nut M-WG10 Straight pipe G1 M-WG1 M-WG10 Straight pipe M-WG02 bend pipe M-WG1 pipe to pipe threaded connecter M-WG11 Locking nut M-WG1 teflon window M-WG11 Locking nut M-WG1 pipe to pipe threaded connecter M-WG11 Locking nut M-WG11 Locking nut M-WG0 waveguide horn M-WG02 end pipe Non accessible / High temperature / Hazard area Non accessible / High temperature / Hazard area
5 Dimensions Waveguides and Waveguide ccessories dditional mounting accessory variants and materials including high temperature ceramics are available. See Gladiator Gen Microwave datasheet available at M-WG0 M-WG0 with M-WG1 window M-WG0 /" SP /" SP /" SP 7.8 M-WG02 /" SP M-WG " SP 88 " NPT THD M-WG12 M-WG12L=xxx /" SP on either ends 2" SP Min Min L= ustomer specified 60 M-WG M-WG " SP /" SP /" SP INT /" SP 5
6 Part Numbers G1 Series Model G1S Gladiator 1 Microwave Integral Sender G1R Gladiator 1 Microwave Integral Receiver, 1 Relay with Failsafe Electronics Housing (Sensor element is 16L with Teflon face) S Powder oated luminium 16L Stainless Steel Power Supply 2VD U 2VD and V Mounting Thread T 1 SP TN 1 NPT pprovals X Not Required 22 TEX Grp II at GD T85 IP67 Tamb -0 to 70 G1S T X Mounting ccessories M 1 1 UHMW Window & mild steel weldment/coupling each 1-SS 1 UHMW Window & 16L stainless steel weldment/coupling each 1-UW 1 UHMW Window each 1-W 1 mild steel weldment/coupling each 1-W-SS 1 16L stainless steel weldment/coupling each 2 2 UHMW Window & mild steel weldment/coupling each 2-SS 2 UHMW Window & 16L stainless steel weldment/coupling each 2-UW 2 UHMW Window each 2-W 2 mild steel weldment/coupling each 2-W-SS 2 16L stainless steel weldment/coupling each M 2 dditional mounting accessory variants and materials including high temperature ceramics are available. See Gladiator Gen Microwave datasheet available at Waveguides & Waveguide accessories M-WG 01 16L Threaded connector for Sender / Receiver 02 16L 90deg bend pipe (150mm + 150mm). Includes qty 2 of M-WG L 1-1/2 Wave guide horn. Includes qty 1 of M-WG1 and qty 1 of M-WG1 0 16L Wave guide horn assembly. Includes qty 1 of M-WG1 and qty 1 of M-WG1 10-L= 1 16L Straight pipe extension 1 L= length in mm. Includes qty 2 of M11-WG L Locking nut 12 2 SP teflon plug with socket to match M-WG0 horn 1 16L Pipe to pipe connector coupling 1 Teflon window to match M-WG0 Horn. Fits into M18 weldment. M-WG 01 6
7 Specifications Specifications See G1 Microwave datasheet for full specifications available at Temperature 16L/0 parts: 800 o eramic parts (alumina ceramic 95%) -50 to 800 o Teflon parts: 250 o UHMW parts: 80 o M-WG0 O-ring seals: NR (Nitrile) 90 o. O-ring can be replaced with appropriate material for application. Weights M-WG01: 0.2kg M-WG02: 0.6kg M-WG0: 0.kg M-WG0: 1.1kg M-WG10L=: 0.2kg per 10cm M-WG11: 0.025kg M-WG12: 0.2kg M-WG1: 0.1kg M-WG1: 0.kg 7
8 Higher Level of Performance HWK, Since 1988 Remote Innovation Hawk Measurement Systems Pty Ltd (HWK) was established in It's founding members saw the universal requirement of various industries requiring improved process control and efficiency in their operations. We an Help HWK understands the difficulties customers face when seeking accurate level measurement. Every application is different, involving a multitude of environmental factors. This is where HWK excels. Our aim is to ensure that customers feel comfortable with our technology, and are provided with long term and reliable solutions. We believe that a combination of application and product expertise, as well as forward thinking and proactive support policies are the foundation of successful customersupplier relationships. Progressive Technical Support HWK believes that the future of the Level Measurement Industry revolves around the quality of pre and post sales - support. Our aim is for all sales & support staff to be product experts, and more importantly application experts making our customers applications as efficient and consistent as possible. HWK understands the need for immediate technical assistance. The HWKLink G communication device allows any computer with internet access and our free GosHawk diagnostic & calibration software; to dial in, calibrate, test, and check the performance of HWK products. This innovative system allows our Global Support Team to assist with commissioning and after sales service of HWK equipment worldwide. Measurement problems are addressed as they happen; not days or weeks later. Knowledge Sharing HWK believes that knowledge sharing is key to creating long term relationships. Empowering our customers and our worldwide distribution network, whilst being available at all times to lend a helping hand, is the perfect recipe for long term solutions and relationships. HWK openly extends an invitation to share our 25 years of level measurement experience, and ensure that your day to day processes are efficient, understood, and always working. ll company or product names are registered trademarks or trademarks of their respective owners. Hawk Measurement Systems (Head Office) Maurice ourt Nunawading VI 11, USTRLI Phone: Fax: info@hawk.com.au Hawk Measurement 96 Glenn Street Lawrence, M 018, US Phone: HWKLEVEL ( ) Phone: Fax: info@hawkmeasure.com For more information and global representatives: dditional product warranty and application guarantees upon request. Technical data subject to change without notice. Represented by: DO-G1MI-SWITH-WP&G-DT Rev
Gladiator G1 Series. Microwave Waveguide Information. Data Sheet. Overview. A Higher Level of Performance. Beam Blockage Detection
Higher Level of Performance Data Sheet Gladiator G Series Microwave Waveguide Information eam lockage Detection For more information, please visit > www.hawkmeasure.com Unit must have T mounting thread
More informationGladiator. Gen 3 Doppler Microwave Switch Series. Data Sheet. Overview. A Higher Level of Performance. Product Flow Detection Circular Polarisation
Overview Higher Level of Performance Data Sheet Gladiator Gen Doppler Microwave Switch Series Product Flow Detection Circular Polarisation For more information, please visit > www.hawkmeasure.com Overview
More informationA Higher Level of Performance. Data Sheet. Hydrobar. Level Transmitters. For more information, please visit >
A Higher Level of Performance Data Sheet Hydrobar Level Transmitters For more information, please visit > www.hawkmeasure.com Overview Hydrobar Overview Description Submersible level transmitters The Hydrobar
More informationHAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX, IECEx)
Heading Product Name A Higher Level of Performance Data Sheet HAWK Magnetostrictive Level Transmitter For more information, please visit > www.hawkmeasure.com Model HLT Transmitter with Analog Output and
More informationHAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)
Heading Product Name A Higher Level of Performance Data Sheet HAWK Magnetostrictive Level Transmitter For more information, please visit > www.hawkmeasure.com Model HLT Transmitter with Analog Output and
More informationGladiator. Gen 3 Microwave Switch Series. Data Sheet. Overview. A Higher Level of Performance. Beam Blockage Detection Circular Polarisation
Overview Gladiator Microwave Series A Higher Level of Performance Data Sheet Gladiator Gen 3 Microwave Switch Series Beam Blockage Detection Circular Polarisation For more information, please visit > www.hawkmeasure.com
More informationGladiator. Gen 3 Microwave Switch Series. Data Sheet. Overview. A Higher Level of Performance. Beam Blockage Detection Circular Polarisation
Gladiator Microwave Series A Higher Level of Performance Data Sheet Gladiator Gen 3 Microwave Switch Series Beam Blockage Detection Circular Polarisation For more information, please visit > www.hawkmeasure.com
More informationSultan Flow. Data Sheet. Overview. A Higher Level of Performance. Real Time Flow Measurement for Liquids.
A Higher Level of Performance Data Sheet Real Time Flow Measurement for Liquids For more information, please click on > www.hawk.com.au Principle of Operation The measurement system operates by transmitting
More informationSultan Liquid- Acoustic Wave Technology
A higher level of performance Data Sheet Sultan Liquid- Acoustic Wave Technology Liquids level and position measurements to 10m (33ft) Principle of Operations The Sultan Liquid series emits a high powered
More informationSultan Acoustic Wave Series
Overview Higher Level of Performance Data Sheet Sultan coustic Wave Series Level, Flow, Positioning, Collision Protection For more information, please visit > www.hawkmeasure.com Overview Principle of
More informationA Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >
A Higher Level of Performance Data Sheet Series 000 Pressure and Level Transmitters For more information, please visit > www.hawkmeasure.com Series 000 000-SAN Cable with separate electronics Description
More informationORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.
A Higher Level of Performance Data Sheet ORCA Sonar System Sludge and Settling Level Interface Monitoring For more information, please visit > www.hawkmeasure.com Overview Principle of Operation The ORCA
More informationGladiator. Doppler Microwave Series. Manual. A Higher Level of Performance. Sultan Sonar Manual Rev 1.0. Product Flow Detection Circular Polarisation
Sultan Sonar Manual Rev.0 A Higher Level of Performance Manual Gladiator Doppler Microwave Series Product Flow Detection Circular Polarisation For more information, please visit > www.hawkmeasure.com Table
More informationFlow Detection MDS Integral or Remote Housing FUNCTION TYPICAL USES. Microwave Doppler Switch Solids - Chute and Conveyor GHz Sender Receiver
Flow Detection MDS Integral or Remote Housing Microwave Doppler Switch Solids - Chute and Conveyor.525 GHz Sender Receiver FUNCTION Flow/no flow detection in solid material handling applications such as
More informationSultan Flow. Data Sheet. Overview. A Higher Level of Performance. Real Time Flow Measurement for Liquids.
A Higher Level of Performance Data Sheet Real Time Flow Measurement for Liquids For more information, please click on > www.hawk.com.au Principle of Operation The measurement system operates by transmitting
More informationORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.
A Higher Level of Performance Data Sheet ORCA Sonar System Sludge and Settling Level Interface Monitoring For more information, please visit > www.hawkmeasure.com Principle of Operation The ORCA Sonar
More informationSultan. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Submerged Interface Level Measurement.
A Higher Level of Performance Data Sheet Sultan Sonar System Sludge and Submerged Interface Level Measurement For more information, please visit > www.hawkmeasure.com Overview Principle of Operation The
More informationSultan Flow. Data Sheet. Real Time Flow Measurement for Liquids. A higher level of performance
higher level of performance Data Sheet Real Time Flow Measurement for Liquids Principle of Operations The measurement system operates by transmitting an acoustic wave signal from its transducer towards
More informationSultan Acoustic Wave Series
A Higher Level of Performance Data Sheet Sultan Acoustic Wave Series Machinery Positioning Systems For more information, please visit > www.hawkmeasure.com Principle of Operation The Sultan for Machinery
More informationSultan. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Submerged Interface Level Measurement.
A Higher Level of Performance Data Sheet Sultan Sonar System Sludge and Submerged Interface Level Measurement For more information, please visit > www.hawkmeasure.com Sultan Sonar Level System System Principle
More informationSultan Radar. Data Sheet. Typical Uses: Typical Features: The New Dimension Radar System. A higher level of performance
higher level of performance Sultan Radar Data Sheet The ew Dimension Radar System The Sultan based Radar System is a high power, high sensitivity narrow beam system which gives excellent performance in
More informationFlow Detection MDS Integral or Remote Housing. Installation and Operating Instructions
Flow Detection MDS Integral or Remote Housing Solids - Chute and Conveyor 10.525 GHz Sender Receiver Installation and Operating Instructions Measurement Systems INTRODUCTION CONTENTS PROPRIETARY NOTICE
More informationORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.
A Higher Level of Performance Data Sheet ORCA Sonar System Sludge and Settling Level Interface Monitoring For more information, please visit > www.hawkmeasure.com Overview Principle of Operation The ORCA
More informationXXXX e. X d.. X X X a
The Heavy Duty incremental encoder type 0H boasts a high degree of ruggedness in a very compact design. Its special construction makes it perfect for all applications in very harsh environments. / RoHS
More informationFOSTEN AUTOMATION SÉRIE F500-RD
FOSTEN AUTOMATION SÉRIE Guided Wave Radar Level Transmitter Guided wave radar level transmitter. Low maintenance, auto calibrated references. Easy installation, directly in tanks or auxiliary vessels.
More informationHAWK GLADIATOR MICROWAVE COLLISION PREVENTION SWITCHES
HAWK GLADIATOR MICROWAVE COLLISION PREVENTION SWITCHES SET UP PROCEDURE 1 Introduction Hawk Gladiator Microwave Switches can be used to detect & indicate a possible collision and therefore prevent boom
More informationIncremental Encoder Model: FOI58
Incremental Encoder Model: FI58 Document no. FI 188 BE Date: 1.01.201 Robust mechanical construction, high vibration and shock resistance 1 to 16,8 pulses/ revolution perating temperature - 0 C to + 85
More informationInstruction Manual for MHE Products DeepWater2 PushPoint Sampler Ver. 2.0 November 21, 2016
Instruction Manual for MHE Products DeepWater2 PushPoint Sampler Ver. 2.0 November 21, 2016 The DeepWater2 is heavier-duty a version of the PushPoint Sampler made of stainless steel pipe instead of SS
More informationFlow Meter FC100. Description FC100. Ordering information
Flow Meter FC00 Microcontroller operated Flow Meter to monitor and display flow rates and temperature. Once correctly adjusted it can also be used for mass flow measurements. Factory preset for air and
More informationSensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering
Change from one to two columns Data Sheet 10/10-3.61-EN Rev. D SensyTemp TSB (B R) Resistance thermometer for building automation, machine construction and environmental engineering Measurement made easy
More informationph or ORP Transmitter
ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes
More informationGladiator. Gen 3 Microwave Switch Series. Manual. A Higher Level of Performance. Sultan Sonar Manual Rev 1.0
Sultan Sonar Manual Rev 1.0 A Higher Level of Performance Manual Gladiator Gen 3 Microwave Switch Series Beam Blockage Detection Circular Polarisation For more information, please visit > www.hawkmeasure.com
More informationConductivity Analyzer
Data Sheet Conductivity Analyzer Comprehensive range of field-proven conductivity cells satisfies broad range of applications. Comprehensive diagnostics facility with in-built software protection ensures
More informationPressure transmitter for mobile hydraulic applications With output signals CANopen and J1939
Electronic pressure measurement Pressure transmitter for mobile hydraulic applications With output signals CNopen and J1939 Model MHC-1 WIK data sheet PE 81.49 pplications Construction machinery gricultural
More informationConductivity Transmitter
Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants
More informationAccuTrak Rotary Position Monitors Explosionproof/Flameproof ATEX/IEC
ccutrak Rotary Position Monitors Explosionproof/Flameproof TEX/IEC Rotary position monitors certified to Ex II G and specifically engineered for hazardous environments. vailable with either low-copper
More informationC10. Data sheet. Force transducer. Special features. B de
C10 Force transducer Data sheet Special features Force transducer for static and dynamic applications Made of non-rusting materials Precise (accuracy class from 0.03) Numerous options (double bridge, TEDS,
More informationValve Island with Electronic I/O
Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication
More informationPaddle wheel flow controller for On/Off control
addle wheel flow controller for On/Off control Type 8032 compact Type 8032 can be combined with... Type 8032 remote Indication, monitoring, transmitting and On/Off control in one device. rogrammable outputs
More informationprocess measurement solutions Mobrey MSP IP wire 24V loop powered ultrasonic level transmitters
process measurement solutions Mobrey MSP 2 wire 24V loop powered ultrasonic level transmitters IP2045 MSP Advanced ultrasonics This new family of ultrasonic non-contacting liquid level transmitters is
More informationRelative Humidity & Temperature Transmitters
Relative Humidity & Temperature Transmitters High Temperature Models up to 150 C (300 F) Series 740 and 741 EMC Immunity to EN 50082-1 Series 741: 2-Wire 4-20mA Ouput Series 740: User- Selectable Signals
More informationThe transducer component converts the measured signal and displays the actual value.
Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version
More informationAccuTrak Rotary Position Monitors Explosionproof/Flameproof ATEX/IEC
ccutrak Rotary Position Monitors Explosionproof/Flameproof TEX/IEC Rotary position monitors certified to Ex II G and specifically engineered for hazardous environments. vailable with either low-copper
More informationData Sheet. Acoustic Wave Series. A higher level of performance. Features:
A higher level of performance Data Sheet Acoustic Wave Series - Level, Flow, Positioning, Collision Protection - Principle of Operations The SULTAN 234 emits a high powered acoustic wave transmit pulse
More informationPart No. Thread Size B Design Load Approx. Wt./100 A in. (mm) Lbs. (kn) Lbs. (kg)
ttachments Fig. 3199R - eiling Flange Fig. 3199RT - eiling Flange ura-opper oated Size Range: 3 /8"-16 & 1 /2"-13 rod Material: Malleable Iron (Stainless Steel Type 304 available) Standard 3199RT is UR-OPPER
More informationXXXX e. X d.. X X X a
The Heavy uty incremental encoder type 0H boasts a high degree of ruggedness in a very compact design. Its special construction makes it perfect for all applications in very harsh environments. / RoHS
More informationElectromotoric actuators
s 4 540 ACVATIX Electromotoric actuators for Combi valves VPI45.., DN40/50 SQD65 operating voltage AC 230 V, 3-position control signal operating voltage AC 24 V, 3-position control signal SQD65 operating
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More informationLocator Accessories DATA SHEETS. Accessory Range for Pipe & Cable Location Equipment
Locator Accessories DATA SHEETS Accessory Range for Pipe & Cable Location Equipment GENERAL PURPOSE SONDE The C.SCOPE 8kHz and 33kHz General Purpose Sondes are transmitters used to trace the direction
More information600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet
Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration
More informationProducts catalogue (I-P Edition)
Products catalogue (I-P Edition) Products catalogue (I-P Edition) FROM QUALITY OUR NATURAL DEVELOPMENT Active in the industry of Refrigeration and Air Conditioning for fifty-five years, Castel is well-established
More informationRCM DIRECT READING FLOWMETER
RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:
More informationQUANTiC series encoder system
L-9517-9778-02-C QUANTiC series encoder system The QUANTiC encoder series provides robust incremental position measurement with excellent metrology and wide installation tolerances that reduce or eliminate
More informationINSERTION paddle wheel flowmeter for continuous flow measurement
INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both
More informationB r e a k t h r o u g h F l o wmeter Technology. Ultrasonic Flowmeter Range
TM B r e a k t h r o u g h F l o wmeter Technology Ultrasonic Flowmeter Range IDEAL FOR: Drink dispensing Laboratory tests Cooling equipment Active flow alarms Semiconductor plant OEM applications Pilot
More informationJumper Assembly Pressure Balanced Oil Filled Cabling Solutions
DEUTSCH Rochester Cable SEACON Jumper Assembly Pressure Balanced Oil Filled Cabling Solutions SEACON Jumper Assembly Pressure Balanced Oil Filled Cabling Solutions Rugged Durability that Runs Deep Subsea
More informationMRS-MRR-MRA. Solid/Liquid Level GHz Sender Receiver
REMOTE AMPLIFIER VERSIO Presence & Absence Detection MRS-MRR-MRA Microwave Pulse Switch Solid/Liquid Level.525 GHz Sender Receiver Safe Alternitive to uclear Switches Replaces Tilt Switches FUCTIO Point
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationA Higher Level of Performance. Manual. OptioLaser S300. Liquid Laser Sensor. For more information, please visit >
A Higher Level of Performance Manual OptioLaser S300 Liquid Laser Sensor For more information, please visit > www.hawkmeasure.com Table of Contents Contents Overview 3 Introduction 3 System Components
More informationCombiTemp TCR6 Standard RTD temperature sensor
Main features Sensor and connection in stainless steel, ISI 6 DIN form B housing Robust design pplications Industrial applications with industrial process connection Pipe systems Heating systems Water
More informationBP Brine Pro Brine Maker. Parts List. This Parts List is for BP-2000 brine makers with serial numbers beginning with and higher.
November, 0 Lit. No., Rev. 0 BP-000 Brine Pro Brine Maker Parts List This Parts List is for BP-000 brine makers with serial numbers beginning with 00 and higher. A DIVISION OF DOUGLAS DYNAMICS, LLC FRAME
More informationCondumax W CLS15 and CLS15D
Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationWe Are the Worldwide Provider for All Your Valve and Fitting Needs
Product Catalog We Are the Worldwide Provider for All Your and Fitting Needs C&C strives to earn your business by offering an extensive line of high quality products with a proven track record for successful
More informationEchotel Model 910 Ultrasonic Level Switch
Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit
More informationCondumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.
Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers
More informationKMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display
Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications
More informationCable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*
Features Assembly Cable gland series for shielded EMC cables Brass nickel-plated or stainless steel AISI 316 Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex d, Ex e and Ex tb Metric and NPT
More informationMagnetic Inductive Flow Sensor induq
Operating manual (Translation) Operating manual... page 1-16 Magnetic Inductive Flow Sensor induq Series VMZ SIKA Ba_VMZ_en 10/2014. Please keep this operating manual for future reference. If the device
More informationINSTALLATION INSTRUCTIONS Y-Connector Accessory (For Multi-Dual Arm Mounting Systems) Model: KSA-1011
INSTALLATION INSTRUCTIONS Y-Connector Accessory (For Multi-Dual Arm Mounting Systems) Model: KSA-1011 Specifications: Installs to K-Series desk or wall mount. Accommodates K-Series mounting arms (fixed
More informationINSTRUCTION MANUAL. Microwave Smart Switch Series. - Beam Blockage Detection - A higher level of performance
INSTRUCTION MNUL Microwave Smart Switch Series - eam lockage Detection - higher level of performance INTRODUCTION Microwave Smart Switch Series CONTENTS PROPRIETRY NOTICE The information contained in this
More informationDigital flow transmitter for continuous flow measurement
Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:
More informationWalk-Behind Broadcast Spreader
January 1, 2019 Lit. No. 83679, Rev. 01 Walk-Behind Broadcast Spreader SP-8 & SP-8SS Parts List This document is for SnowEx SP-8 walk-behind broadcast spreaders beginning with serial numbers PD-288 and
More informationMagnetic Inductive Flow Sensors induq. Series VMI
Magnetic Inductive Flow Sensors induq Series VMI Free Flow! Compact - cost-effective - robust! The induq from SIKA is a trio of extremly compact, low cost, magnetic inductive fl ow sensors. This new product
More informationThis specification describes the minimum requirements for piping systems for the following service:
SPEC-3004 1/7 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Service Water Design Conditions Operating Conditions 10 PSIG @ 33 o F to
More informationU15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants
U15 Force transducer Special features - Tensile/compressive force transducer - Nominal (rated) forces 2.5 kn to 2.5 MN - lass 0.5 to ISO 376 in force measurement range between 10% and 100% of the nominal
More informationProcess Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors
Process Automation Accurate Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors Flexible Sensors and Systems: www.fafnir.com Reliable FAFNIR Sensors and Systems Reliable,
More information600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)
Specification Sheet 600T Series Transmitters Model 65T Electronic temperature transmitter (PC programmable) High flexibility and wide rangeability Single transmitter accepts RTD/THC/mV/ohm Galvanically
More informationSultan 2 - Acoustic Wave Technology
A higher level of performance Sultan 2 - Acoustic Wave Technology 2 Wire Solids / Liquids level measurements to 60m (196ft) Data Sheet Principle of Operations The SULTAN 2 emits a high powered acoustic
More informationProcess Protection Acoustic sensors for pump monitoring
coustic sensors for pump monitoring acoustic diagnostic unit Overview The acoustic diagnostic unit acoustically measures the structure-borne noise In the version for pump monitoring; on oscillating displacement
More informationHopper and Drive Components
January, 07 Lit. No. 7586, Rev. 00 Hopper and Drive Components Model SP-00- & SP-5- Low-Profile Tailgate Spreader Parts List This manual is for SnowEx SP-00- & SP-5- tailgate spreaders with serial numbers
More informationOperating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher
Operating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher Model # 100 Standard Model #100-U Heavy Duty CAUTION: Read and Understand
More informationQUANTiC series encoder system
L-9517-9778-03-A QUANTiC series encoder system The QUANTiC encoder series provides robust incremental position measurement for linear and rotary systems with excellent metrology and wide installation tolerances.
More informationEchotel Model 910 Ultrasonic Level Switch
Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit
More informationTEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions
Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof
More informationGas Mass Flow Control Products
Gas Mass Flow Control Products The Standard of Excellence in Mass Flow Porter Mass Flow products reflect over four decades of experience in the design and manufacture of precision instruments for the measurement
More informationElectromagnetic flowmeters and switches DWM 1000/2000
KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass
More informationModular Radio Telemetry System
Simple to Use Remote Control 8 Channels per Transmitter 16 Channels per Receiver Upto 48 Transmitters per system Auto Transmit Mode Secure RF Protocol Automatic Watchdog Transmission Range: Upto 200 metres
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationOur Company. We are major supplier to:
VACUUM METROLOGY Our Company Hositrad Holland and Hositrad Deutschland combine more than 50 years of experience in vacuum and cryogenic technology. Customers profit from a broad range of capabilities,
More informationDigital conductivity transmitter
Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due
More informationThis specification describes the minimum requirements for piping systems for the following service:
201/01/13 1/ 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Service Air Design Conditions Operating Conditions Blast Air (see Note 1)
More informationUlt r a s o n i c le v e l me t e r s ULM 55
Ult r a s o n i c le v e l me t e r s ULM 55 For continuous level measurement of liquids (even if polluted), mash and paste materials in open or closed vessels, sumps, open channels etc. Xi version for
More informationGrundfos Direct Sensor
GRUNDFOS DT OOKLET Grundfos Direct Sensor sensors Grundfos Direct Sensor Table of contents 1. Product introduction 3 Type key 4 2. Relative- sensor, Industry (RPI) 5 RPI / RPI +T general data 5 RPI, 0-0.6
More informationAmer Technical Information TI 312e00 Solids Content Sensor SAH-T/E Solids Content Sensor for Average Concentrations Using the Light Abso
Technical Information TI 312e00 Solids Content Sensor 51508363 7510 SAH-T/E Solids Content Sensor for Average Concentrations Using the Light Absorption Method The 7510 sensor is used for optical solid
More informationDUK COMPACT ULTRASONIC FLOWMETER
DUK COMPACT ULTRASONIC FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Measuring Ranges: 0.0- GPM to 0.6-60 GPM Accuracy: ±. % of F.S. Turndown Ratio: 0: P max : 30 PSI; T max
More informationElectromagnetic Flowmeter
Data Sheet Electromagnetic Flowmeter MagMaster Loflo Industry-specific design for the water and waste water industries in diameters from 5mm ( /2 in.) to 6mm (24in.) Wide flow range with.25% accuracy Extended
More informationDouble-Ridged Waveguide Horn Antennas
Models 3112, 3106B, 3119, 3115, 3117, 3116C Double-Ridged Waveguide Horn Antennas User Manual ETS-Lindgren Inc. Although the information in this document has been carefully reviewed and is believed to
More informationRoof Mount Ground Mount Specialised Clamps Spares Application Notes
DPA Solar Racking Solutions Solar PV Racking Catalogue Roof Mount Ground Mount Specialised Clamps Spares Application Notes www.dpasolar.com.au 1300 447 500 Rails & Splices Page 3 Mid & End Clamps Page
More informationT40B. Torque Flange. Special features. Data sheet. Overall concept
T40B Torque Flange Special features - Nominal (rated) torques 50 N m, 0 N m, 200 N m, 500 N m, 1 kn m, 2 kn m, 3 kn m, 5 kn m and kn m - Nominal rated rotational speed up to 24000 rpm (depending on nominal
More informationThis specification describes the minimum requirements for piping systems for the following service:
SPEC-3501 1/ 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Instrument Air Design Conditions 150 PSIG @ 180 F Operating Conditions 125
More information