Grundfos Direct Sensor

Size: px
Start display at page:

Download "Grundfos Direct Sensor"

Transcription

1 GRUNDFOS DT OOKLET Grundfos Direct Sensor sensors

2 Grundfos Direct Sensor Table of contents 1. Product introduction 3 Type key 4 2. Relative- sensor, Industry (RPI) 5 RPI / RPI +T general data 5 RPI, bar (0-8.7 psi) 6 RPI, bar ( psi) 7 RPI, bar ( psi) 8 RPI, bar ( psi) 9 RPI, bar ( psi) 10 RPI, bar ( psi) 11 RPI, bar ( psi) 12 RPI, bar ( psi) 13 RPI, bar ( psi) ccessories 51 Sensor interface, SI 001 PSU 51 M12 cable 51 Capillary tube 51 daptor for mounting in Grundfos CR pumps 51 Sensor interface, SI 010 CNV ppendix 53 Installation of RPI, DPI sensor Grundfos Product Center Differential- sensor, Industry (DPI)15 DPI, general data 15 DPI, bar (0-8.7 psi) 16 DPI, bar ( psi) 17 DPI, bar ( psi) 18 DPI, bar ( psi) 19 DPI, bar ( psi) 20 DPI, bar ( psi) 21 DPI, bar ( psi) 22 DPI, bar ( psi) Differential- sensor, Industry (DPI V.2) 24 DPI V.2, general data 24 DPI V.2, bar (0-8.7 psi) 25 DPI V.2, bar ( psi) 26 DPI V.2, bar ( psi) 27 DPI V.2, bar ( psi) 28 DPI V.2, bar ( psi) 29 DPI V.2, bar ( psi) 30 DPI V.2, bar ( psi) 31 DPI V.2, bar ( psi) Relative- sensor, Standard (RPS) 33 RPS, general data 33 RPS, bar (0-8.7 psi) 34 RPS, bar ( psi) 35 RPS, bar ( psi) 36 RPS, bar ( psi) 37 RPS, bar ( psi) 38 RPS, bar ( psi) 39 RPS, bar ( psi) Differential- sensor, Standard (DPS) 41 DPS, general data 41 DPS, bar (0-8.7 psi) 42 DPS, bar ( psi) 43 DPS, bar ( psi) 44 DPS, bar ( psi) 45 DPS, bar ( psi) 46 DPS, bar ( psi) Product range 48 RPI sensor 48 DPI V.2 sensor 49 DPI sensor 50 RPS, DPS sensor 50 2

3 Grundfos Direct Sensor 5 5. Relative- sensor, Standard (RPS) RPS, general data Fig. 101 RPS sensor Technical overview The RPS sensor is a combined pressure and temperature sensor (two-in-one solution) from Grundfos Direct Sensors. The RPS sensors are fully compatible with wet, aggressive media. They use MEMS sensing technology in combination with the corrosion-resistant Silicoat coating technology on the sensor chip. pplications Water treatment and distribution water utility water monitoring HVC systems chiller systems HPC and IT cooling systems micro CHP heat pumps solar systems: heating and cooling. Features Wide temperature measuring range: C ( F) compact design MEMS technology. ranges [bars] [psi] enefits and temperature measurement in one sensor (two-in-one solution) compatible with wet, aggressive media accurate, linearised and temperature-compensated output signal quick temperature response (direct contact with medium) cost-effective and robust design system solution with Grundfos pumps. TM TM pprovals WRS KTW CS. Certificates Electrical connections Fig. 102 Electrical connections Power supply requirements 5 VDC separated from hazardous live circuitry by double or reinforced insulation power limitation of 150 V; current limitation of 8. Options + 75 CE C, CS, US C-Tick Pin Description Colour 1 signal (0.5 to 3.5 V relative to pin 3) Yellow 2 signal (0.5 to 3.5 V relative to pin 3) White 3 GND (0 V) Green 4 Voltage supply (+5 VDC), PELV rown Fig. 103 sensor options Pos. V 1 V 2 PE Description 1/2'' nipple, stainless steel (316L) 3 Cable connection: Overmoulded (left) Cable connection: Snap-on (right) 4 Pipe system TM TM TM Relative- sensor, Standard (RPS) 33

4 5 Grundfos Direct Sensor Relative- sensor, Standard (RPS) RPS, bar (0-8.7 psi) Fig. 104 RPS sensor Dimensions [mm] C Fig. 105 Dimensions of RPS sensor C D E F G mm in [V] D E F G TM TM Specifications C C C C Media and environment Media (peak) mbient air temperature mbient air temperature (peak) Humidity System burst pressure Electrical data bar (0-8.7 psi) ± 2 % FS ± 3 % FS < 0.5 s 5 mbar (0.07 psi) ± 1 K ± 2 K < 1.5 s 0.5 K Liquids C ( F), non-freezing C ( F) C ( F) 0-95 % (relative), non-condensing 30 bar (435 psi) 5 VDC (± 5 %), PELV Power supply Grounding of sensor supply recommended. signal signal Power consumption < 50 mw Load impedance > 10 kω Maximum cable length 3 m (9.8 ft) Sensor materials Sensor Silicon-based MEMS sensor Seal (sensor to housing) EPDM Housing Composite (PPS) Wetted materials Corrosion-resistant coating, EPDM, FKM, PPS Environmental standards Enclosure class IP44 cycling IEC Vibration (non-destructive) Hz, 10G, 4 h Electromagnetic compatibility EN P max T max TM Fig. 106 and temperature response of RPS sensor 34

5 Grundfos Direct Sensor 5 RPS, bar ( psi) Fig. 107 RPS sensor Dimensions [mm] C Fig. 108 Dimensions of RPS sensor C D E F G mm in [V] D E F G TM TM Specifications C C C C Media and environment Media (peak) mbient air temperature mbient air temperature (peak) Humidity System burst pressure Electrical data bar ( psi) ± 2 % FS ± 3 % FS < 0.5 s 5 mbar (0.07 psi) ± 1 K ± 2 K < 1.5 s 0.5 K Liquids C ( F), non-freezing C ( F) C ( F) 0-95 % (relative), non-condensing 30 bar (435 psi) 5 VDC (± 5 %), PELV Power supply Grounding of sensor supply recommended. signal signal Power consumption < 50 mw Load impedance > 10 kω Maximum cable length 3 m (9.8 ft) Sensor materials Sensor Silicon-based MEMS sensor Seal (sensor to housing) EPDM Housing Composite (PPS) Wetted materials Corrosion-resistant coating, EPDM, FKM, PPS Environmental standards Enclosure class IP44 cycling IEC Vibration (non-destructive) Hz, 10G, 4 h Electromagnetic compatibility EN Relative- sensor, Standard (RPS) P max T max TM Fig. 109 and temperature response of RPS sensor 35

6 5 Grundfos Direct Sensor Relative- sensor, Standard (RPS) RPS, bar ( psi) Fig. 110 RPS sensor Dimensions [mm] Fig. 111 C D Dimensions of RPS sensor C D E F G mm in [V] E F G TM TM Specifications C C C C Media and environment Media (peak) mbient air temperature mbient air temperature (peak) Humidity System burst pressure Electrical data bar ( psi) ± 1.5 % FS ± 2.5 % FS < 0.5 s 5 mbar (0.07 psi) ± 1 K ± 2 K < 1.5 s 0.5 K Liquids C ( F), non-freezing C ( F) C ( F) 0-95 % (relative), non-condensing 30 bar (435 psi) 5 VDC (± 5 %), PELV Power supply Grounding of sensor supply recommended. signal signal Power consumption < 50 mw Load impedance > 10 kω Maximum cable length 3 m (9.8 ft) Sensor materials Sensor Silicon-based MEMS sensor Seal (sensor to housing) EPDM Housing Composite (PPS) Wetted materials Corrosion-resistant coating, EPDM, FKM, PPS Environmental standards Enclosure class IP44 cycling IEC Vibration (non-destructive) Hz, 10G, 4 h Electromagnetic compatibility EN P max T max TM Fig. 112 and temperature response of RPS sensor 36

7 Grundfos Direct Sensor 5 RPS, bar ( psi) Fig. 113 RPS sensor Dimensions [mm] Fig. 114 C D Dimensions of RPS sensor C D E F G mm in [V] E F G TM TM Specifications C C C C Media and environment Media (peak) mbient air temperature mbient air temperature (peak) Humidity System burst pressure Electrical data bar ( psi) ± 1.5 % FS ± 2 % FS < 0.5 s 20 mbar (0.29 psi) ± 1 K ± 2.5 K < 1.5 s 0.5 K Liquids C ( F), non-freezing C ( F) C ( F) 0-95 % (relative), non-condensing 30 bar (435 psi) 5 VDC (± 5 %), PELV Power supply Grounding of sensor supply recommended. signal signal Power consumption < 50 mw Load impedance > 10 kω Maximum cable length 3 m (9.8 ft) Sensor materials Sensor Silicon-based MEMS sensor Seal (sensor to housing) EPDM Housing Composite (PPS) Wetted materials Corrosion-resistant coating, EPDM, FKM, PPS Environmental standards Enclosure class IP44 cycling IEC Vibration (non-destructive) Hz, 10G, 4 h Electromagnetic compatibility EN Relative- sensor, Standard (RPS) P max T max TM Fig. 115 and temperature response of RPS sensor 37

8 5 Grundfos Direct Sensor Relative- sensor, Standard (RPS) RPS, bar ( psi) Fig. 116 RPS sensor Dimensions [mm] Fig. 117 C D Dimensions of RPS sensor C D E F G mm in [V] E F G TM TM Specifications C C C C Media and environment Media (peak) mbient air temperature mbient air temperature (peak) Humidity System burst pressure Electrical data bar ( psi) ± 2 % FS ± 2.5 % FS < 0.5 s 20 mbar (0.29 psi) ± 1 K ± 2 K < 1.5 s 0.5 K Liquids C ( F), non-freezing C ( F) C ( F) 0-95 % (relative), non-condensing 30 bar (435 psi) 5 VDC (± 5 %), PELV Power supply Grounding of sensor supply recommended. signal signal Power consumption < 50 mw Load impedance > 10 kω Maximum cable length 3 m (9.8 ft) Sensor materials Sensor Silicon-based MEMS sensor Seal (sensor to housing) EPDM Housing Composite (PPS) Wetted materials Corrosion-resistant coating, EPDM, FKM, PPS Environmental standards Enclosure class IP44 cycling IEC Vibration (non-destructive) Hz, 10G, 4 h Electromagnetic compatibility EN P max T max TM Fig. 118 and temperature response of RPS sensor 38

9 Grundfos Direct Sensor 5 RPS, bar ( psi) Fig. 119 RPS sensor Dimensions [mm] C Fig. 120 Dimensions of RPS sensor C D E F G mm in [V] D E F G TM TM Specifications C C C C Media and environment Media (peak) mbient air temperature mbient air temperature (peak) Humidity System burst pressure Electrical data bar ( psi) ± 2 % FS ± 2.5 % FS < 0.5 s 20 mbar (0.29 psi) ± 1 K ± 2.5 K < 1.5 s 0.5 K Liquids C ( F), non-freezing C ( F) C ( F) 0-95 % (relative), non-condensing 30 bar (435 psi) 5 VDC (± 5 %), PELV Power supply Grounding of sensor supply recommended. signal signal Power consumption < 50 mw Load impedance > 10 kω Maximum cable length 3 m (9.8 ft) Sensor materials Sensor Silicon-based MEMS sensor Seal (sensor to housing) EPDM Housing Composite (PPS) Wetted materials Corrosion-resistant coating, EPDM, FKM, PPS Environmental standards Enclosure class IP44 cycling IEC Vibration (non-destructive) Hz, 10G, 4 h Electromagnetic compatibility EN Relative- sensor, Standard (RPS) P max T max TM Fig. 121 and temperature response of RPS sensor 39

10 5 Grundfos Direct Sensor Relative- sensor, Standard (RPS) RPS, bar ( psi) Fig. 122 RPS sensor Dimensions [mm] C Fig. 123 Dimensions of RPS sensor C D E F G mm in [V] D E F G TM TM Specifications C C C C Media and environment Media (peak) mbient air temperature mbient air temperature (peak) Humidity System burst pressure Electrical data bar ( psi) ± 2 % FS ± 2.5 % FS < 1.0 / 1.5 s 20 mbar (0.29 psi) ± 1 K ± 2.5 K < 1.5 s 0.5 K Liquids C ( F), non-freezing C ( F) C ( F) 0-95 % (relative), non-condensing 30 bar (435 psi) 5 VDC (± 5 %), PELV Power supply Grounding of sensor supply recommended. signal signal Power consumption < 50 mw Load impedance > 10 kω Maximum cable length 3 m (9.8 ft) Sensor materials Sensor Silicon-based MEMS sensor Seal (sensor to housing) EPDM Housing Composite (PPS) Wetted materials Corrosion-resistant coating, EPDM, FKM, PPS Environmental standards Enclosure class IP44 cycling IEC Vibration (non-destructive) Hz, 10G, 4 h Electromagnetic compatibility EN P max T max TM Fig. 124 and temperature response of RPS sensor 40

11 Grundfos Direct Sensor 6 6. Differential- sensor, Standard (DPS) DPS, general data TM enefits and temperature measurement in one sensor (two-in-one solution) compatible with wet, aggressive media accurate, linearised and temperature-compensated output signal quick temperature response (direct contact with medium) cost-effective and robust design system solution with Grundfos pumps. pprovals WRS KTW CS. Differential- sensor, Standard (DPS) Fig. 125 DPS sensor Certificates Technical overview The DPS sensor is a combined differential-pressure and temperature sensor (two-in-one solution) from Grundfos Direct Sensors. The DPS sensors are fully compatible with wet, aggressive media. They use MEMS sensing technology in combination with the corrosion-resistant Silicoat coating technology on the sensor chip CE C, CS, US C-Tick Electrical connections pplications Water treatment and distribution water utility water monitoring HVC systems chiller systems HPC and IT cooling systems micro CHP heat pumps solar systems: heating and cooling. Features Wide temperature measuring range: C ( C) compact design MEMS technology. ranges [bars] [psi] Fig. 126 Electrical connections Pin Description Colour 1 signal (0.5 to 4.5 V relative to pin 3) Yellow 2 signal (0.5 to 4.5 V relative to pin 3) White 3 GND (0 V) Green 4 Voltage supply (+5 VDC), PELV rown Power supply requirements 5 VDC separated from hazardous live circuitry by double or reinforced insulation power limitation of 150 V; current limitation of 8. Options V Part Housing for DPS Fitting 6 mm (0.23") Fitting 8 mm (0.31") ISI 316 Fitting 6 mm (0.23") Fitting 8 mm (0.31") Wall bracket (housing for DPS) V PE Pipe system Tube connection Compression fitting TM

12 6 Grundfos Direct Sensor Differential- sensor, Standard (DPS) DPS, bar (0-8.7 psi) Fig. 127 DPS sensor Dimensions [mm] C C D E F G H mm /8-27 in NPT [V] 0 2 x H Fig. 128 Differential-pressure and temperature response of DPS sensor D F E P max T max G TM TM TM Specifications bar (0-8.7 psi) C ± 2 % FS ± 3.0 % FS < 0.5 s System pressure deviation 6 mbar/bar (0.09 psi/psi) 1.2 mbar (0.02 psi) C ± 1 K ± 2 K, sensing element to output < 1.0 s change 0.2 K Media and environment Media Liquids (peak) C ( F), non-freezing mbient air temp C ( F) mbient air temp. (peak) C ( F) Humidity (relative) 0-95 %, non-condensing System pressure, p 1 Max. 16 bar at 70 C (232 psi at 158 F) Max. 12 bar at 100 C (174 psi at 212 F) Differential pressure, p 1 - p 2 Max. 10 bar (145 psi) urst pressure, p 1 Max. 30 bar (435 psi) urst pressure, p 2 Max. 10 bar (145 psi) Electrical data Power supply 5 VDC (± 5 %), PELV. Grounding of sensor supply required. Ratiometric signal V signal V Power consumption < 50 mw Load impedance > 10 kω Maximum cable length 3 m (9.8 ft) Sensor materials Sensing element Silicon-based MEMS sensor Sealing cap EPDM Housing Composite (PPS) Wetted materials Corrosion-resistant coating, EPDM, FKM, PPS Environmental standards Enclosure class IP44 cycling IEC Vibration (nondestructive) Hz, 10G, 4 h Electromagnetic compatibility EN

13 Grundfos Direct Sensor 6 DPS, bar ( psi) Fig. 129 DPS sensor Dimensions [mm] C C D E F G H mm /8-27 in NPT [V] 0 2 x H Fig. 130 Differential-pressure and temperature response of DPS sensor D F E P max T max G TM TM TM Specifications bar ( psi) C ± 2 % FS ± 3.0 % FS < 0.5 s System pressure deviation 6 mbar/bar (0.09 psi/psi) 1.3 mbar (0.02 psi) C ± 1 K ± 2 K, sensing element to output < 1.0 s change 0.2 K Media and environment Media Liquids (peak) C ( F), non-freezing mbient air temp C ( F) mbient air temp. (peak) C ( F) Humidity (relative) 0-95 %, non-condensing System pressure, p 1 Max. 16 bar at 70 C (232 psi at 158 F) Max. 12 bar at 100 C (174 psi at 212 F) Differential pressure, p 1 - p 2 Max. 10 bar (145 psi) urst pressure, p 1 Max. 30 bar (435 psi) urst pressure, p 2 Max. 10 bar (145 psi) Electrical data Power supply 5 VDC (± 5 %), PELV. Grounding of sensor supply required. Ratiometric signal V signal V Power consumption < 50 mw Load impedance > 10 kω Maximum cable length 3 m (9.8 ft) Sensor materials Sensing element Silicon-based MEMS sensor Sealing cap EPDM Housing Composite (PPS) Wetted materials Corrosion-resistant coating, EPDM, FKM, PPS Environmental standards Enclosure class IP44 cycling IEC Vibration (nondestructive) Hz, 10G, 4 h Electromagnetic compatibility EN Differential- sensor, Standard (DPS) 43

14 6 Grundfos Direct Sensor Differential- sensor, Standard (DPS) DPS, bar ( psi) Fig. 131 DPS sensor Dimensions [mm] C C D E F G H mm /8-27 in NPT [V] 0 2 x H Fig. 132 Differential-pressure and temperature response of DPS sensor D F E P max T max G TM TM TM Specifications bar ( psi) C ± 2 % FS ± 2.5 % FS < 0.5 s System pressure deviation 6 mbar/bar (0.09 psi/psi) 1.6 mbar (0.023 psi) C ± 1 K ± 2 K, sensing element to output < 1.0 s change 0.2 K Media and environment Media Liquids (peak) C ( F), non-freezing mbient air temp C ( F) mbient air temp. (peak) C ( F) Humidity (relative) 0-95 %, non-condensing System pressure, p 1 Max. 16 bar at 70 C (232 psi at 158 F) Max. 12 bar at 100 C (174 psi at 212 F) Differential pressure, p 1 - p 2 Max. 10 bar (145 psi) urst pressure, p 1 Max. 30 bar (435 psi) urst pressure, p 2 Max. 10 bar (145 psi) Electrical data Power supply 5 VDC (± 5 %), PELV. Grounding of sensor supply required. Ratiometric signal V signal V Power consumption < 50 mw Load impedance > 10 kω Maximum cable length 3 m (9.8 ft) Sensor materials Sensing element Silicon-based MEMS sensor Sealing cap EPDM Housing Composite (PPS) Wetted materials Corrosion-resistant coating, EPDM, FKM, PPS Environmental standards Enclosure class IP44 cycling IEC Vibration (nondestructive) Hz, 10G, 4 h Electromagnetic compatibility EN

15 Grundfos Direct Sensor 6 DPS, bar ( psi) Fig. 133 DPS sensor Dimensions [mm] C C D E F G H mm /8-27 in NPT [V] 0 2 x H Fig. 134 Differential-pressure and temperature response of DPS sensor D F E P max T max G TM TM TM Specifications bar ( psi) C ± 2 % FS ± 2.5 % FS < 0.5 s System pressure deviation 6 mbar/bar (0.09 psi/psi) 2.5 mbar (0.07 psi) C ± 1 K ± 2 K, sensing element to output < 1.0 s change 0.2 K Media and environment Media Liquids (peak) C ( F), non-freezing mbient air temp C ( F) mbient air temp. (peak) C ( F) Humidity (relative) 0-95 %, non-condensing System pressure, p 1 Max. 16 bar at 70 C (232 psi at 158 F) Max. 12 bar at 100 C (174 psi at 212 F) Differential pressure, p 1 - p 2 Max. 10 bar (145 psi) urst pressure, p 1 Max. 30 bar (435 psi) urst pressure, p 2 Max. 10 bar (145 psi) Electrical data Power supply 5 VDC (± 5 %), PELV. Grounding of sensor supply required. Ratiometric signal V signal V Power consumption < 50 mw Load impedance > 10 kω Maximum cable length 3 m (9.8 ft) Sensor materials Sensing element Silicon-based MEMS sensor Sealing cap EPDM Housing Composite (PPS) Wetted materials Corrosion-resistant coating, EPDM, FKM, PPS Environmental standards Enclosure class IP44 cycling IEC Vibration (nondestructive) Hz, 10G, 4 h Electromagnetic compatibility EN Differential- sensor, Standard (DPS) 45

16 6 Grundfos Direct Sensor Differential- sensor, Standard (DPS) DPS, bar ( psi) Fig. 135 DPS sensor Dimensions [mm] C C D E F G H mm /8-27 in NPT [V] 0 2 x H Fig. 136 Differential-pressure and temperature response of DPS sensor D F E P max T max G TM TM TM Specifications bar ( psi) C ± 2 % FS ± 2.5 % FS < 0.5 s System pressure deviation 6 mbar/bar (0.09 psi/psi) 4.0 mbar (0.06 psi) C ± 1 K ± 2 K, sensing element to output < 1.0 s change 0.2 K Media and environment Media Liquids (peak) C ( F), non-freezing mbient air temp C ( F) mbient air temp. (peak) C ( F) Humidity (relative) 0-95 %, non-condensing System pressure, p 1 Max. 16 bar at 70 C (232 psi at 158 F) Max. 12 bar at 100 C (174 psi at 212 F) Differential pressure, p 1 - p 2 Max. 10 bar (145 psi) urst pressure, p 1 Max. 30 bar (435 psi) urst pressure, p 2 Max. 10 bar (145 psi) Electrical data Power supply 5 VDC (± 5 %), PELV. Grounding of sensor supply required. Ratiometric signal V signal V Power consumption < 50 mw Load impedance > 10 kω Maximum cable length 3 m (9.8 ft) Sensor materials Sensing element Silicon-based MEMS sensor Sealing cap EPDM Housing Composite (PPS) Wetted materials Corrosion-resistant coating, EPDM, FKM, PPS Environmental standards Enclosure class IP44 cycling IEC Vibration (nondestructive) Hz, 10G, 4 h Electromagnetic compatibility EN

17 Grundfos Direct Sensor 6 DPS, bar ( psi) Fig. 137 DPS sensor Dimensions [mm] C C D E F G H mm /8-27 in NPT [V] 0 2 x H Fig. 138 Differential-pressure and temperature response of DPS sensor D F E P max T max G TM TM TM Specifications bar ( psi) C ± 2 % FS ± 2.5 % FS < 0.5 s System pressure deviation 6 mbar/bar (0.09 psi/psi) 6.0 mbar (0.09 psi) C ± 1 K ± 2 K, sensing element to output < 1.0 s change 0.2 K Media and environment Media Liquids C (peak) C ( F), non-freezing mbient air temp C ( F) mbient air temp. (peak) C ( F) Humidity (relative) 0-95 %, non-condensing System pressure, p 1 Max. 16 bar at 70 C (232 psi at 158 F) Max. 12 bar at 100 C (174 psi at 212 F) Differential pressure, p 1 - p 2 Max. 10 bar (145 psi) urst pressure, p 1 Max. 30 bar (435 psi) urst pressure, p 2 Max. 10 bar (145 psi) Electrical data Power supply 5 VDC (± 5 %), PELV. Grounding of sensor supply required. Ratiometric signal V signal V Power consumption < 50 mw Load impedance > 10 kω Maximum cable length 3 m (9.8 ft) Sensor materials Sensing element Silicon-based MEMS sensor Sealing cap EPDM Housing Composite (PPS) Wetted materials Corrosion-resistant coating, EPDM, FKM, PPS Environmental standards Enclosure class IP44 cycling IEC Vibration (nondestructive) Hz, 10G, 4 h Electromagnetic compatibility EN Differential- sensor, Standard (DPS) 47

18 7 Grundfos Direct Sensor Product range 7. Product range RPI sensor Scope of delivery: RPI sensor 2 m cable (6.5 ft) quick guide. O-ring Complete product range range Thread Product number measurement EPDM FKM RPI b-1-C-N -EG W RPI b-1-C-N -VG W bar RPI b-1-F-N -EG W 1 (0-8.7 psi) RPI b-1-F-N -VG W RPI b-1-C-N -EG W RPI b-1-C-N -VG W bar RPI b-1-F-N -EG W 1 ( psi) RPI b-1-F-N -VG W RPI b-1-C-N -EG W RPI b-1-C-N -VG W bar RPI b-1-F-N -EG W 1 ( psi) RPI b-1-F-N -VG W RPI b-1-C-N -EG W RPI b-1-C-N -VG W bar RPI b-1-F-N -EG W 1 ( psi) RPI b-1-F-N -VG W RPI b-1-C-N -EG W RPI b-1-C-N -VG W bar RPI b-1-F-N -EG W 1 ( psi) RPI b-1-F-N -VG W RPI b-1-C-N -EG W RPI b-1-C-N -VG W bar RPI b-1-F-N -EG W 1 ( psi) RPI b-1-F-N -VG W RPI- 0-10b-1-C-N -EG W RPI- 0-10b-1-C-N -VG W bar RPI- 0-10b-1-F-N -EG W 1 ( psi) RPI- 0-10b-1-F-N -VG W RPI- 0-16b-1-C-N -EG W RPI- 0-16b-1-C-N -VG W bar RPI- 0-16b-1-F-N -EG W 1 ( psi) RPI- 0-16b-1-F-N -VG W RPI- 0-25b-1-C-N -EG W RPI- 0-25b-1-C-N -VG W bar RPI- 0-25b-1-F-N -EG W 1 ( psi) RPI- 0-25b-1-F-N -VG W

19 Grundfos Direct Sensor 7 DPI V.2 sensor Scope of delivery: DPI V.2 sensor 2 m cable (6.5 ft) capillary tube with fitting quick guide. Product range O-ring Complete product range range Thread Product number measurement EPDM FKM DPI b-2-C-M2.000X-EG6- - -SW DPI b-2-C-M2.000X-VG6- - -SW bar DPI b-2-F-M2.000X-EG6- - -SW 1 (0-8.7 psi) DPI b-2-F-M2.000X-VG6- - -SW DPI b-2-C-M2.000X-EG6- - -SW DPI b-2-C-M2.000X-VG6- - -SW bar DPI b-2-F-M2.000X-EG6- - -SW 1 ( psi) DPI b-2-F-M2.000X-VG6- - -SW DPI b-2-C-M2.000X-EG6- - -SW DPI b-2-C-M2.000X-VG6- - -SW bar DPI b-2-F-M2.000X-EG6- - -SW 1 ( psi) DPI b-2-F-M2.000X-VG6- - -SW DPI b-2-C-M2.000X-EG6- - -SW DPI b-2-C-M2.000X-VG6- - -SW bar DPI b-2-F-M2.000X-EG6- - -SW 1 ( psi) DPI b-2-F-M2.000X-VG6- - -SW DPI b-2-C-M2.000X-EG6- - -SW DPI b-2-C-M2.000X-VG6- - -SW bar DPI b-2-F-M2.000X-EG6- - -SW 1 ( psi) DPI b-2-F-M2.000X-VG6- - -SW DPI b-2-C-M2.000X-EG6- - -SW DPI b-2-C-M2.000X-VG6- - -SW bar DPI b-2-F-M2.000X-EG6- - -SW 1 ( psi) DPI b-2-F-M2.000X-VG6- - -SW DPI- 0-10b-2-C-M2.000X-EG6- - -SW DPI- 0-10b-2-C-M2.000X-VG6- - -SW bar DPI- 0-10b-2-F-M2.000X-EG6- - -SW 1 ( psi) DPI- 0-10b-2-F-M2.000X-VG6- - -SW DPI- 0-16b-2-C-M2.000X-EG6- - -SW DPI- 0-16b-2-C-M2.000X-VG6- - -SW bar DPI- 0-16b-2-F-M2.000X-EG6- - -SW 1 ( psi) DPI- 0-16b-2-F-M2.000X-VG6- - -SW

20 7 Grundfos Direct Sensor Product range DPI sensor The DPI sensor is available as a single sensor as well as in sets with capillary tubes. s standard, the scope of delivery includes: DPI sensor cable with bracket installation and operating instructions for Grundfos DPI sensor. See table below for sets with special parts. Product description range Cable length Wall bracket Motor bracket Capillary tube Reducing piece 7/16-20 UNF - R 1/4 Service instructions Product number DPI Complete bar (0-8.7 psi) DPI Complete bar ( psi) DPI Complete bar ( psi) DPI Complete bar ( psi) DPI Complete bar ( psi) DPI Complete bar ( psi) DPI Complete bar ( psi) DPI Set bar (0-8.7 psi) DPI Set bar ( psi) DPI Set bar ( psi) DPI Set bar ( psi) DPI Set bar ( psi) DPI Set bar ( psi) DPI Set bar ( psi) DPI Set bar ( psi) 5 m (16.4 ft) DPI Set bar ( psi) 5 m (16.4 ft) DPI Set 2Wou bar ( psi) 5 m (16.4 ft) DPI Set bar ( psi) 5 m (16.4 ft) DPI Set bar ( psi) 5 m (16.4 ft) RPS, DPS sensor Grundfos offers a wide range of custom-built RPS and DPS sensors. The RPS and DPS sensors can be customized depending on the application. Therefore, please contact Grundfos Direct Sensors when proceeding to selection. 50

21 Grundfos Direct Sensor 8 8. ccessories Sensor interface, SI 001 PSU The sensor interface, type SI 001 PSU, from Grundfos Direct Sensors is an external power supply for the DPI sensor. The external power supply must be used where the distance between the sensor and the controller is longer than 30 m (98 ft). daptor for mounting in Grundfos CR pumps This adaptor is required when mounting the RPI / RPI+T or DPI V.2 / DPI V.2 +T on CR pumps. Grundfos CR pump size Pump type CR, CRE ccessories CRI, CRIE CRN, CRNE Fig. 139 sensor interface, SI 001 PSU TM Does not require an adaptor. Requires an adaptor if the sensor and coupling guard are in direct contact (will create unnecessary acoustic noise). lways requires an adaptor. Description Product number Specifications: Voltage range: VC. Frequency: Hz. mbient temperature: -20 to +50 C (-4 to 122 F). Enclosure class: IP54. Part Product number Sensor interface, SI 001 PSU M12 cable 4-wire screened cable with M12 connector in sensor end and open end in equipment end. daptor for RPI / RPI+T and DPI / DPI+T Description Length Product number Cable, industry M2.000X 2 m (6.6 ft) Cable, industry M5.000X 5 m (16.4 ft) Capillary tube The capillary tube is used together with the DPI / DPI V.2 and DPI+T / DPI V.2 +T to connect the sensor to the low-pressure side of the equipment. Description Product number Capillary tube 7/16-20 UNF 00ID

22 8 Grundfos Direct Sensor ccessories Sensor interface, SI 010 CNV The sensor interface, type SI 010 CNV, from Grundfos Direct Sensors is an external power supply, signal amplifier and signal converter for Grundfos sensors, standard variants (VFS, RPS, DPS). SI 010 CNV has built-in precision resistors enabling the sensor to send 4-20 m, 1-5 V and 2-10 V output signals. SI 010 CNV should be used in applications where sensors from the standard product range are used, but the controller requires a 4-20 m input signal. TM Fig. 140 Sensor interface, SI 010 CNV Specifications: Voltage range: VC ± 10 % or 24 VDC. Frequency: Hz. Power consumption: max. 2.5 W. mbient temperature: -20 to +50 C (-4 to 122 F). Enclosure class: IP20. Part Product number Sensor interface, SI 010 CNV, IP

23 Grundfos Direct Sensor 9 9. ppendix Installation of RPI, DPI sensor ppendix RPI P2 P1 Sensor 2 Sensor 1 Pump/system DPI P1 Sensor (p-) P2 (p+) Pump/system! M12 M12, IP67, UL CCN: CYJV and CYJV7 >65 C (>149 F) ISO 228/ 1 G½ EPDM, FKM 32 mm 20 Nm d1 d1 = 16.3 mm d2 = 2.4 mm d2-25 to Max. 28 bar IP67-30 to 120 C 60 C (406 PSI) (-22 to 248 F) (-13 to 140 F) TM

24 10 Grundfos Direct Sensor Grundfos Product Center 10. Grundfos Product Center Online search and sizing tool to help you make the right choice. SIZING enables you to size a pump based on entered data and selection choices. REPLCEMENT enables you to find a replacement product. Search results will include information on the lowest purchase price the lowest energy consumption the lowest total life cycle cost. CTLOGUE gives you access to the Grundfos product catalogue. LIQUIDS enables you to find pumps designed for aggressive, flammable or other special liquids. ll the information you need in one place Downloads Performance curves, technical specifications, pictures, dimensional drawings, motor curves, wiring diagrams, spare parts, service kits, 3D drawings, documents, system parts. The Product Center displays any recent and saved items - including complete projects right on the main page. On the product pages, you can download installation and operating instructions, data booklets, service instructions, etc. in PDF format. Subject to alterations. 54

25 55

26 ECM: The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding /S or Grundfos /S, Denmark. ll rights reserved worldwide. Copyright Grundfos Holding /S GRUNDFOS /S DK-8850 jerringbro. Denmark Telephone:

Your Global Automation Partner. PT2000 Pressure Transmitter

Your Global Automation Partner. PT2000 Pressure Transmitter Your Global Automation Partner PT000 Pressure Transmitter PT000 Pressure Transmitters Solution for demanding pressure measurements Turck's PT000 pressure transmitters offer an ideal solution for demanding

More information

Pressure Transmitter SIL

Pressure Transmitter SIL Pressure Transmitter SI Characteristics - TRANSDUCER - Pressure: Range: Output: Accuracy: Temperature of medium: Material enclosure: Pressure connection: Electrical connection: Protection: relative / absolute

More information

XPC10 High temperature miniature pressure sensor

XPC10 High temperature miniature pressure sensor Absolute, sealed and gauge ranges 10 to 500 bar [150 to 7 500 psi] High temp. operation from -40 up to 220 ºC [-40 to 428 F] Stainless steel construction Amplified output available For static and dynamic

More information

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939 Electronic pressure measurement Pressure transmitter for mobile hydraulic applications With output signals CNopen and J1939 Model MHC-1 WIK data sheet PE 81.49 pplications Construction machinery gricultural

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0) DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter for general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter for general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Machine tools Measurement and control technology

More information

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter for general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter for general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Machine tools Measurement and control technology

More information

ED701 General Industry Pressure Transmitter

ED701 General Industry Pressure Transmitter ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Ship building Measurement and control technology

More information

Electronic Temperature Transmitters

Electronic Temperature Transmitters Electronic Temperature Transmitters ELECTRONIC TEMPERATURE TRANSMITTERS As with the pressure transmitters, HYDAC ELECTRONIC also has temperature transmitters appropriate for every application. The transmitters

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding

More information

Technical Data Measuring principle Thick-film-on-ceramic 25 C typ. ± 0.3 % FS typ. (± 0.5 % FS typ., ± 1 % FS typ.)

Technical Data Measuring principle Thick-film-on-ceramic 25 C typ. ± 0.3 % FS typ. (± 0.5 % FS typ., ± 1 % FS typ.) ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economic transmitter

More information

OEM pressure transmitter For mobile working machines Model MH-3

OEM pressure transmitter For mobile working machines Model MH-3 Electronic pressure measurement OEM pressure transmitter For mobile working machines Model MH-3 WIKA Data sheet PE 81.59 Applications Load monitoring Load moment limitation Hydraulic drive control Special

More information

Industrial Pressure Transmitter

Industrial Pressure Transmitter Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economic transmitter ECT

More information

ECT Applications. Features

ECT Applications. Features ECT 847 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter

More information

High-quality pressure transmitter For general industrial applications Model S-10

High-quality pressure transmitter For general industrial applications Model S-10 Electronic pressure measurement High-quality pressure transmitter For general industrial applications Model S-10 WIKA data sheet PE 81.01 for further approvals see page 4 Applications Machine building

More information

INDUSTRIAL PRESSURE TRANSMITTER

INDUSTRIAL PRESSURE TRANSMITTER ECT 87 INDUSTRIAL PRESSURE TRANSMITTER Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economic transmitter

More information

NAT Applications. Features

NAT Applications. Features NAT 85 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of pressure and temperature. The industrial

More information

High-quality pressure transmitter For general industrial applications Model S-20

High-quality pressure transmitter For general industrial applications Model S-20 Electronic pressure measurement High-quality pressure transmitter For general industrial applications Model S-20 WIKA data sheet PE 81.61 Applications Critical industrial applications Demanding applications

More information

Miniature pressure sensor

Miniature pressure sensor SPECIFICATIONS Ranges 0.5 to 350 bar [7 psi to 5 000 psi] Absolute, sealed and gauge Titanium construction For static and dynamic applications Linearity up to ±0.25% FS The XP5 serie is designed in titanium

More information

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5) Pressure OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5) WIKA data sheet PE 81.65 for further approvals see page 11 Applications Hydraulics and pneumatics Pumps and compressors

More information

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation Pressure Transmitter ATM.ECO - Analog Pressure Transmitter with Temperature Compensation CUSTOMER BENEFITS Entry level series into precision pressure measurement High measurement accuracy is ensured by

More information

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5) Electronic pressure measurement OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5) WIKA data sheet PE 81.65 Applications Hydraulics and pneumatics Pumps and compressors

More information

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet PX2 Series bar to 46 bar 00 kpa to 4.6 MPa 5 psi to 667 psi Datasheet Table. Electrical Specifications Characteristic Ratiometric Regulated Transfer Function Order Code (See Figure 5.) AA AB AC AD CH BC

More information

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

NAT Applications. Features

NAT Applications. Features NAT 85 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of pressure and temperature. The industrial

More information

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350 Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350 Technical brochure Features Designed for use in severe maritime environments For medium and ambient temperatures

More information

Relative and absolute pressure transmitter type 528

Relative and absolute pressure transmitter type 528 Relative and absolute pressure transmitter type 528 The compact type 528 pressure transmitter is based upon the Huba Control developed and since over 20 years well proven ceramic technology. These transmitters

More information

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

Pressure measurement PBMR Fully welded pressure transmitter for railway applications Fully welded pressure transmitter for railway Product highlights Ecellent accuracy and long term stability up to % FS Active temperature compensation over the entire operating temperature range Sensor

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm Electronic pressure measurement Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm WIKA data sheet PE 86.05 Applications Process technology Machine building and plant

More information

GRUNDFOS DATA BOOKLET DIP. Measuring amplifiers and controllers, preassembled systems. Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP)

GRUNDFOS DATA BOOKLET DIP. Measuring amplifiers and controllers, preassembled systems. Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP) GRUNDFOS DATA BOOKLET Measuring amplifiers and controllers, preassembled systems Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP) Table of contents 1. Product introduction 3 measuring amplifier and controller

More information

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters Class l, Division 1 Group A-D IIC T4 As our products are continuously improved, we reserve the right to make any change in the stated

More information

Electronic Pressure Switch Type MEP

Electronic Pressure Switch Type MEP MAKING MODERN LIVING POSSIBLE Data sheet Electronic Pressure Switch Type MEP MEP 2200 and MEP 2250 versions: Dual output Output : Switch output Hysteresis % FS Time constant ms Output 2: Analogue output

More information

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE

More information

DN 16 ISO-KF. Dimensional drawings THERMOVAC TM 101 (mm)

DN 16 ISO-KF. Dimensional drawings THERMOVAC TM 101 (mm) Products Handheld Measuring Instruments Digital PIEZOVAC Sensor PV 101 Digital THERMOVAC Sensor TM 101 The digital compact PIEZOVAC PV 101 and THERMOVAC TM 101 combine high-quality sensor technology with

More information

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING Technical leaflet 2 RD.5G.H4.02 Danfoss A/S (IC-MC/mr), 09-2004 Introduction AKS 32 and AKS 33 are pressure transmitters that

More information

Paddle wheel flow controller for On/Off control

Paddle wheel flow controller for On/Off control addle wheel flow controller for On/Off control Type 8032 compact Type 8032 can be combined with... Type 8032 remote Indication, monitoring, transmitting and On/Off control in one device. rogrammable outputs

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

Materials (other materials see WIKA diaphragm seal program) Model S-10

Materials (other materials see WIKA diaphragm seal program) Model S-10 2.0 Specifications WIKA Tronic catalog pages and data sheets have a consistent layout of technical information that is required to select the correct transmitter. The second page of the data sheet lists

More information

XP5 Miniature pressure sensor

XP5 Miniature pressure sensor Absolute, sealed and gauge ranges 1 to 350 [15 psi to 5 000 psi] Titanium construction Amplified output available For static and dynamic applications Linearity up to ±0.25% FSO DESCRIPTION The XP5 miniature

More information

Low Pressure NSL Applications. Features

Low Pressure NSL Applications. Features NSL 87 Low Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The very compact NSL low transmitter

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.8... 4 mm Port connection 1/8, 1/4 or sub-base Type 2873 can be combined with Type 8605 Digital

More information

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in

More information

TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN

TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN TECHNICAL DATA TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN Main features Ranges: from 0...10 to 0...1000 bar Output signal 4...0mA -wires / 0.1...5.1Vdc / 0.1...10.1Vdc / 0...5Vdc

More information

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction

More information

Pressure transmitters SPTW

Pressure transmitters SPTW Product range overview Method of measurement Pressure measuring range [bar] Measured variable Pneumatic connection Operating voltage Electrical connection [V DC] Piezoresistive pressure sensor Thin-film

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Pressure transmitter AKS 32 and AKS 33

Pressure transmitter AKS 32 and AKS 33 Data sheet Pressure transmitter AKS 32 and AKS 33 AKS 32 and AKS 33 are pressure transmitters that measure a pressure and convert the measured value to a standard signal: y 1 5 V DC or 0 10 V DC for AKS

More information

DTM.OCS.S/N - Modbus Level Transmitter

DTM.OCS.S/N - Modbus Level Transmitter Digital Submersible Level Transmitter with Modbus Interface DTM.OCS.S/N - Modbus Level Transmitter CUSTOMER BENEFITS High precision digital level transmitter with standard Modbus interface Fast customization

More information

Valve Island with Electronic I/O

Valve Island with Electronic I/O Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication

More information

Process Protection Acoustic sensors for pump monitoring

Process Protection Acoustic sensors for pump monitoring coustic sensors for pump monitoring acoustic diagnostic unit Overview The acoustic diagnostic unit acoustically measures the structure-borne noise In the version for pump monitoring; on oscillating displacement

More information

Relative and absolute pressure transmitter type 528

Relative and absolute pressure transmitter type 528 Relative and absolute pressure transmitter type 528 Pressure range -1... 0 60 bar Váš dodavatel: JSP, s.r.o. Raisova 547 506 01 Jičín JSP Měření a regulace www.jsp.cz tel.: +420 493 760 811 fax: +420 493

More information

PD30ETD10xxSA. Photoelectrics, Diffuse reflective. Main features. Description

PD30ETD10xxSA. Photoelectrics, Diffuse reflective. Main features. Description Photoelectrics, Diffuse reflective Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments. They are designed for use in

More information

Temposonics. Magnetostrictive Linear Position Sensors. ET Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. ET Analog Data Sheet Temposonics Magnetostrictive Linear Position Sensors ET Analog High operating temperature Compact sensor housing ATEX / IECEx / CEC / NEC certified MEASURING TECHNOLOGY The absolute, linear position sensors

More information

Conductivity Transmitter

Conductivity Transmitter Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants

More information

SUNSTAR 传感与控制 TEL: FAX: Relative and absolute pressure transmitter type 528

SUNSTAR 传感与控制   TEL: FAX: Relative and absolute pressure transmitter type 528 Relative and absolute pressure transmitter type 528 Pressure range -1... 0 60 bar The compact type 528 pressure transmitter is based upon the well proven ceramic technology developed by Huba Control over

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters ll 2G EEx ia llc T6 As our products are continuously improved, we reserve the right to make any change in the stated specifications

More information

Electronic temperature switch with display Model TSD-30

Electronic temperature switch with display Model TSD-30 Electrical temperature measurement Electronic temperature switch with display Model TSD-30 WIKA data sheet TE 67.03 Applications Machine tools Hydraulic power packs Coolant and lubrication systems Machine

More information

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor GmbH Postal address: House address Fon (+49) 0 22 42-870-0 Postbox 26 Löhestr. 7 Fax (+49) 0 22 42-870-20 http: // www.tematec.de 5759 Hennef 577 Hennef e-mail: team@tematec.de Data Sheet Page /5 Intelligent

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

2/2 way Proportional Valve (motordriven)

2/2 way Proportional Valve (motordriven) 2/2 way Proportional (motordriven) Actuator isolated from fl ow path Excellent range and fast response times Low power consumption Orifi ce sizes 8 to 25 mm Versions: Standard, positioner, process controller

More information

Series 10-ZSE30A(F)/10-ISE30A

Series 10-ZSE30A(F)/10-ISE30A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High-Precision Digital Pressure Switch Clean series For positive For vacuum/ compound Rated range ISEA 0.1 to 1 MPa How to Order 10 ISEA 01 N M 01 N01 C4H

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

Incremental Encoder Model: FOI58

Incremental Encoder Model: FOI58 Incremental Encoder Model: FI58 Document no. FI 188 BE Date: 1.01.201 Robust mechanical construction, high vibration and shock resistance 1 to 16,8 pulses/ revolution perating temperature - 0 C to + 85

More information

B2 Series Characterized Control Valve, Spring Return Actuator

B2 Series Characterized Control Valve, Spring Return Actuator Series Characterized Control Valve, Spring ctuator Two-way Valve with Stainless Steel all and Stem, NPT Female Ends Service: Flow Characteristic: Media Temp Range: Maximum Differential: Pressure ( P) mbient

More information

M5200 Industrial Pressure Transducer

M5200 Industrial Pressure Transducer SPECIFICATIONS Wide Temperature Range Compact Variety of Pressure Ports and Electrical Configurations Optional Stainless Steel Snubber CE Compliant and Weatherproof Gage, Sealed, Compound The M5200 pressure

More information

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8 to 1/2 NPT. Proportional Valves. Features. 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/8" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Control achieved by applying straight voltage between 0 and 24 VDC

More information

RS /M MZ SERIES

RS /M MZ SERIES The RS 310-410-510-610/M MZ burners series covers a firing range from 1300 to 6300 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic

More information

CombiTemp TCR6 Standard RTD temperature sensor

CombiTemp TCR6 Standard RTD temperature sensor Main features Sensor and connection in stainless steel, ISI 6 DIN form B housing Robust design pplications Industrial applications with industrial process connection Pipe systems Heating systems Water

More information

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F,

More information

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU Level probe Features Assembly Device for hydrostatic pressure measurement in liquids High resistance to overload High-precision, robust ceramic measuring cell with longterm stability Simultaneous level

More information

U5700 Submersible Liquid Level Pressure Transducer

U5700 Submersible Liquid Level Pressure Transducer High Accuracy CE Compliant Compact Variety of Pressure Port Configurations Waterproof Optional Stainless Steel Snubber IP68 Rated Connection and Submersible Polyurethane Jacketed Cable Gage, Sealed, Absolute,

More information

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics

More information

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span 2-way motor valve Actuator isolated from flow path Excellent range and fast response times Low power consumption Orifice sizes 1 to 10 mm Versions: Standard, positioner, process controller and high pressure

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

IP26 Series Current to Pneumatic Converter

IP26 Series Current to Pneumatic Converter Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear

More information

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering Change from one to two columns Data Sheet 10/10-3.61-EN Rev. D SensyTemp TSB (B R) Resistance thermometer for building automation, machine construction and environmental engineering Measurement made easy

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Relative pressure transmitter type 522 for shipbuilding

Relative pressure transmitter type 522 for shipbuilding Relative pressure transmitter type 522 for shipbuilding Pressure range 0... 2.5 1000 bar The compact type 522 pressure transmitter for shipbuilding is based upon the Huba Control developed thick film technology

More information

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763)

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763) A Sensor Designed with the Customer Applications in Mind! High Accuracy The PS400 and PS500 provide an accuracy rating of ±0.5 percent of the full scale. Flexible Mounting Options Multiple threaded connections

More information

U5300 Industrial Pressure Transducer

U5300 Industrial Pressure Transducer Superior Accuracy and Total Error Band Instrument Grade CE Compliant Compact Variety of Pressure Ports and Electrical Configurations Optional Stainless Steel Snubber Weatherproof Gage, Sealed, Absolute,

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

OPTIFLUX 1000 Technical Datasheet

OPTIFLUX 1000 Technical Datasheet OPTIFLUX 1000 Technical Datasheet Electromagnetic flow sensor in sandwich design Lightweight and compact Excellent price performance ratio Quick and easy to install The documentation is only complete when

More information

Series 10-ZSE80/10-ISE80

Series 10-ZSE80/10-ISE80 Series 0-ZSE80/0-ISE80 RoHS -Color Display Digital Pressure Switch For General Fluids Directional Control Valves For positive 0 80 For vacuum/ compound 80 80F N P B R T S V Rated range Symbol -X50 Clean

More information

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Ultrasonic level measuring device, non-contact

Ultrasonic level measuring device, non-contact Ultrasonic level measuring device, non-contact For level measurement up to 8 m 4... 20 ma/hart - 2 wires Suitable for solids ATEX approvals Type 8177 can be combined with... Type 8611 Type 8793 Type 8802-GB

More information

Low Frequency Velocity Sensor

Low Frequency Velocity Sensor 330505 Low Frequency Velocity Sensor Product Datasheet Bently Nevada* Asset Condition Monitoring Product Datasheet The Bently Nevada 330505 Low Frequency Velocity Sensor is specifically designed for hydroelectric

More information

Heavy Duty Pressure Transducers

Heavy Duty Pressure Transducers Installation Instructions for the Heavy Duty Pressure Transducers General Information Honeywell s PX3 Series Pressure Transducers use piezoresistive sensing technology with ASIC (Application Specific Integrated

More information

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description Photoelectrics, Background suppression reflective - PointSpot Main features Miniature sensor range The visible red PointSpot light makes alignment very easy Range: 250 mm Sensitivity adjustment by potentiometer

More information

phix Compact 4.10 PH, TEMPERATURE AND REDOX MEASUREMENT DATASHEET EN 4.10 PHIX DATASHEET 1812

phix Compact 4.10 PH, TEMPERATURE AND REDOX MEASUREMENT DATASHEET EN 4.10 PHIX DATASHEET 1812 PH, TEMPERATURE AND REDOX MEASUREMENT General The advanced and unique design of phix Compact ensures that your work is done fast, easy and with accuracy. The compact design offers a union in one end, and

More information

prosonic T FMU230, FMU231

prosonic T FMU230, FMU231 Technical Information prosonic T FMU230, FMU231 Ultrasonic Level Measurement Compact transmitters for non-contact level measurement of fluids and coarse bulk materials Application The compact transmitters

More information