1 2007 Technical Documentation Pressure Independent Characterized Control Valves (PICCV) Patented Effective December 2007 Table of Contents Control Valve Product Range...2 Valve /Actuator Selection At A Glance...4 Pressure Independent Characterized Control Valves (PICCV) Features and Benefits...6 1/2 to 1 without P/T Ports...8 1/2 to 2 with P/T Ports Larger Flow PICCV with P/T Ports...10 Technical Data...12 Feedback Charts...35 Field Adjustable Flow Ranges and P/T Port Pressure Flow Data...51 Field Adjustable Flow Ranges and P/T Port Pressure Flow Data for Customized Flows...52 Available Customized Flows and Certified Factory Calibrated Flows...53 PICCV Running Times...54 Field Adjustment of Flow and Valve Sizing and Selection...56 PICCV Test and Balance Procedure...57 Parallel Piping Information...58 Dimensions...59 Wiring Diagrams...61 Heat Pump Applications (PICCV) Features and Benefits /2 to 1 without P/T Ports /2 to 1 with P/T Ports...67 Technical Data...68 Dimensions...69 Wiring Diagrams...69 Accessories...70 Flexible Products...71 Valve Specifications...75 Actuator/Valve Specifications...77 Terms and Conditions of Sale and Warranty Custom MFT Configuration Order Form....82

2 Control Valve Product Range Electronic Pressure Independent Characterized Control Valves U.S. Patent Electronic Characterized Control Valves U.S. Patent Electronic Zone Valves PICCV CCV PICCV Service: Flow Rate: Material: Control: Two-way 1/2 to 2 Chilled/Hot Water, 60% glycol GPM Brass Body Brass/Stainless Trim Floating Multi-Function Technology Spring Return or Non-Spring Return Typical Application Air Handling Units: Heating Coils Cooling Coils Unit Ventilators VAV Box Re-heat Coils Heat Pumps B2 Series B3 Series B6 Series Two-way Three-way Mixing/Diverting Two-way Flanged 1/2 to 3 Service: Chilled/Hot Water, 60% glycol C v Range: Material: Stainless Trim or Brass Trim Control: On/Off, Floating, 2-10 VDC Multi-Function Technology Spring Return or Non-Spring Return Typical Application Air Handling Units: Heating Coils Cooling Coils Fan Coil Units: Heating Coils Cooling Coils Unit Ventilators VAV Box Re-heat Coils Bypass Loops ZONE2 N Series Two-way NPT ZONE2 S Series Two-way Sweat ZONE3 N Series Three-way Diverting NPT ZONE3 S Series Three-way Diverting Sweat Service: Chilled/Hot Water, 50% glycol C v Range: Material: Brass Body Control: On/Off Spring Return Typical Application Fan Coil Units: 1/2 to 1 Baseboard Radiation Heating Coils Cooling Coils For detailed information and submittal data, see Technical Documentation at or on CD-ROM. 2

3 Control Valve Product Range Electronic Globe Valves Electronic Butterfly Valves Electronic Ball Valves VS Series G2 (S) Two-way Screwed Series Bronze or Stainless Trim G6 C (S) Two-way Flanged ANSI 125 S e r i e s Bronze or Stainless Trim G6 (S) Two-way Flanged ANSI 125 S e r i e s Bronze or Stainless Trim G6 (S)-250 Two-way Flanged ANSI 250 Series Bronze or Stainless Trim G3 (D) Three-way Screwed Series Bronze Trim G7 D (S) Three-way Flanged Series ANSI 125 Bronze or Stainless Trim G7 D (S)-250 Three-way Flanged Series ANSI 250 Bronze or Stainless Trim Three-way Valves available in Mixing or Diverting Service: C v Range: Material: Control: 1/2 to 6 Chilled/Hot Water, 60% Glycol, Steam (Two-way) (Three-way Mix.) (Three-way Div.) Stainless Steel Stem, Bronze Trim or Stainless Trim On/Off, Floating, 2-10 VDC Multi-Function Technology Spring Return or Non-Spring Return Typical Application Air Handling Units: Heating Coils Cooling Coils Fan Coil Units: Heating Coils Cooling Coils Unit Ventilators VAV Box Re-heat Coils Bypass Loops F6 Series (HS,HSU) F7 Series (HS,HSU) Two-way Three-way Mixing/Diverting F6 SHP Two-way ANSI 150/300 Series F7 SHP Three-way ANSI 150/300 Series Mixing/Diverting Typical Application Chiller and Cooling Tower Isolation Change-over Systems Large Air Handler Coil Control Bypass Control Applications B2 VS Series B3 VS Series B2 VSS Series B6 VS Series 2 to 30 1/2 to 10 Service: Chilled/Hot Water, 50% Glycol C v Range: ,426 Material: Stainless Shaft Stainless Disc Cast Iron, Full Lug Body EPDM Liner Control: On/Off, Floating, 2-10 VDC On/Off, Floating 2-10 VDC, 1-5 VDC, 4-20mA (NEMA 4 Actuator) Multi-Function Technology Spring Return or Non-Spring Return Two-way Screwed Stainless Steel Trim Three-way Mixing/ Diverting Screwed Stainless Steel Trim Two-way Screwed Stainless Steel Body and Trim Two-way Flanged Stainless Steel Trim Service: Chilled/Hot Water, 50% Glycol, Steam C v Range: 1 to 12,400 Material: Bronze or Stainless Body Stainless Steel Trim RPTFE Seats Control: On/Off, Floating, 2-10 VDC On/Off, Floating 2-10 VDC, 1-5 VDC, 4-20mA (NEMA 4 Actuator) Multi-Function Technology Spring Return or Non-Spring Return Typical Application Unit Ventilators Humidifiers Heating and Cooling Coils For detailed information and submittal data, see Technical Documentation at or on CD-ROM. Call Customer Service to discuss your application. 3

4 Valve/Actuator Selection At A Glance Base product nomenclature PICCV PT + LRX24-MFT VALVE ACTUATOR P I C C V P T L R X M F T VALVE SIZES GPM Ex: 003 = 3.0 GPM 24 VAC/DC Power* Valve Designation Sizes PICCV 15 1/2 20 3/ / / LR AR DESIGNATOR MFT DESCRIPTION Multi-Function Technology (MFT) 2 10 VDC Control or Selectable (See MFT chart opposite) -3 Floating control TYPE OF VALVE PRESSURE INDEPENDENT CHARACTERIZED CONTROL VALVE (PICCV) P I C C V 2-way Chrome Plated Brass Ball & Brass Stem TF LF AF D e s c r i p t i o n P T with P/T ports to measure delta P to verify the flow rate without P/T port s 4

5 Valve/Actuator Selection At A Glance Specify upon ordering P NO+AHU MFT CONFIGURATION SET-UP TAGGING P N O A H U SET UP* Non-Spring Models NO = Normally Open NC = Normally Closed Spring Return Models NO/FO = Normally Open/Fail Open NO/FC = Normally Open/Fail Closed NC/FO = Normally Closed/Fail Open NC/FC = Normally Closed/Fail Closed *Refers to valve port inlet to outlet, per flow arrow designation TAGGING Valves may be tagged per customer specification Example: AHU FCU-2 Valve set up required prior to ordering. Multi-Function Technology Model Control Input Running Time Built-in Feedback List Price P VDC VDC No Charge P VDC VDC No Charge P VDC VDC No Charge P VDC VDC No Charge P VDC VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P Floating Point VDC No Charge P-10019* On/Off VDC No Charge E x a m p l e : LRX24-MFT is the basic model. Add the P pre-set MFT configuration number and list price to the actuator when ordering, as needed. Note: Most popular configurations available at no additional cost. All other configurations carry a $30.00 list price. *Please Note: For On/Off control input, please order P and wire as on/off. ORDERING EXAMPLE 1 2 Choose the desired valve/actuator combination based on valve ratings and actuator control parameters from the following pages. PICCV PT + LRX24-MFT Specify Configuration (important) Multi-Function Technology: P (2-10 VDC input / 2-10 VDC feedback) Set-up: NO (Normally Open) Tagging: AHU PICCV PT+LRX24-MFT+P NO+AHU Total List Price 5

6 Pressure Independent Characterized Control Valves (PICCV) Features and Benefits Characterizing disc made of Tefzel known for excellent strength and chemical resistance Thermal isolating adapter between flange and actuator Easy direct coupling of actuator with a single screw Vent holes reduce condensation build-up Actuator can be mounted in four different positions Pe rpendicular mounting flange and square dri ve head eliminate l a t e ral forces on the stem Blow-out proof stem with thrust-bearing Teflon disc and double O-ring design for long service life* Forged brass valve body no pin-hole leaks Teflon seats with O-rings provide constant seating force against the ball and Non-corroding Regulator Assembly Patented Disadvantages of Today s Systems Time consuming balancing effort Rebalancing required when adding to system or remodeling Poor valve authority at average or low load Balancing procedure dictates quality Potential spreading of control problems can occur when one or more loops are instabl e, due to intera c t i ve nature of circuits Low T reduces efficiency of chillers, condensing boilers, or coils Starving of terminals in less favored spaces results in long start-up time Advantages of the PICCV Easy selection, no Cv calculation required Hydronic balancing is simplified, as the circuits are not interactive Flexible commissioning One piece installation saves 50% of labor costs, installation space, and investment for for balancing valve Reduces pumping costs Maintains T for higher efficiency of chillers and condensing boilers Visualizes flow in a BMS system and provides accurate flow for each degree of opening Prevents overflow or underflow for fast start-up Features Automatic dynamic system balancing Field adjustable flow rate 5 50 PSI differential pressure operating range (gradual flow will increase from 0-5 PSI) GPM (1/2 2 ) 5 year warranty Options P/T ports for flow or temperature measurement Belimo PC-Tool for commissioning Customized Flows Certified Factory Calibrated Flows Weather shields Auxiliary switches Metric threads *Teflon is a registered product of Dupont 6

7 Pressure Independent Characterized Control Valve TM (PICCV) The Best Way to Control Flow Maintain design flow independent of pressure variations The PICCV is a two-way valve that will supply a specific flow for each degree of ball opening regardless of pressure variations in a system. Flow accuracy ± 5% (5 to 50 PSI) (absolute) Variation due to ± 5% (5 to 50 PSI) manufacturing tolerances Hysteresis 1% (absolute) Operation PICCV consists of a differential pressure regulator in series with a control valve. Regulator Section Control Valve Section The amount of flow that passes through the valve is controlled by the use of a pressure regulator that moves according to the change in pressure above and below it. Water exits valve pressure is P2 (low) All pressure changes are absorbed by the pressure regulator allowing the differential pressure to be held constant over the control valve section thereby giving the same flow. Water enters valve pressure is P1 (high) Water passes through regulator, disc, and ball pressure drops Ports sense pressure drop and transfer it through this channel below regulator Low pressure pulls regulator down against the spring force hence reducing the regulator opening, reducing the flow. 7

8 P2 Series Pressure Independent Characterized Control Valve with MFT, Non-Spring Return Actuator Two-way Valve with Chrome Plated Brass Ball and Brass Stem, NPT Female Ends Service: Flow Characteristic: Media Temp Range: Ambient Temp Range: Differential Pressure Across Valve Range ( P): chilled or hot water, 60% glycol equal percentage 0 F to 212 F [-18 C to 100 C] -22 F to 122 F [-30 C to 50 C] 5 to 50 psid Maximum Flow Setting: Manual Field Adjustable LRB24-3 Actuators PC Tool Field Adjustable MFT Actuators LRB P2 Pressure Independent Characterized Control Valve, Chrome Plated Brass Ball and Brass Stem Va l v e Non-Spring Return Actuator M o d e l Va l v e Floating Proportional/MFT # F l ow Rate Nominal Size C l o s e - P I C C V L i t e r / D N O f f Va l v e G P M s e c I n ch e s m m p s i LRB24-3 LRX24-MFT PICCV * / Pg 12 Pg 13 PICCV * / Pg 12 Pg 13 PICCV * / Pg 12 Pg 13 PICCV * / Pg 12 Pg 13 PICCV * / Pg 12 Pg 13 PICCV * / Pg 12 Pg 13 PICCV * / Pg 12 Pg 13 PICCV / Pg 12 Pg 13 PICCV / Pg 12 Pg 13 PICCV / Pg 12 Pg 13 PICCV / Pg 12 Pg 13 PICCV / Pg 12 Pg 13 PICCV ** Pg 12 Pg 13 PICCV ** Pg 12 Pg 13 PICCV ** Pg 12 Pg 13 PICCV ** Pg 12 Pg 13 Electrical 3 ft cable 3 ft cable Connection 1/2 conduit fitting 1/2 conduit fitting When ordering MFT, see configuration codes under MFT Adjustment Tables (for example, see page 14). Note: FlowSetR only available on (-3) actuator. Refer to page 53 for customized flows and certified factory calibration flows. Options (add to list price) LRB24-3-S Built-in aux. switch (-S) Pg 12 * 1 / 2 body has two different disc sizes (.50 GPM to 1 GPM) (1.5 GPM to 5.5 GPM) * * 1 body has two different disc sizes (11 GPM to 16 GPM) (17 GPM to 19 GPM) 8

9 P2 Series Pressure Independent Characterized Control Valve with MFT, Spring Return Actuator Two-way Valve with Chrome Plated Brass Ball and Brass Stem, NPT Female Ends Service: Flow Characteristic: Media Temp Range: Ambient Temp Range: Differential Pressure Across Valve Range ( P): chilled or hot water, 60% glycol equal percentage 0 F to 212 F [-18 C to 100 C] -22 F to 122 F [-30 C to 50 C] 5 to 50 psid Maximum Flow Setting: PC Tool Field Adjustable MFT Actuators TF LF P2 Pressure Independent Characterized Control Valve, Chrome Plated Brass Ball and Brass Stem Va l v e Spring Return Actuator M o d e l Va l v e Proportional/MFT # F l ow Rate Nominal Size C l o s e - P I C C V L i t e r / D N O f f Va l v e G P M s e c I n ch e s m m p s i TF24-MFT US LF24-MFT US PICCV * / Pg 17 Pg 19 PICCV * / Pg 17 Pg 19 PICCV * / Pg 17 Pg 19 PICCV * / Pg 17 Pg 19 PICCV * / Pg 17 Pg 19 PICCV * / Pg 17 Pg 19 PICCV * / Pg 17 Pg 19 PICCV / Pg 19 PICCV / Pg 19 PICCV / Pg 19 PICCV / Pg 19 PICCV / Pg 19 PICCV ** Pg 19 PICCV ** Pg 19 PICCV ** Pg 19 PICCV ** Pg 19 Electrical 3 ft cable 3 ft cable Connection 1/2 conduit fitting 1/2 conduit fitting When ordering MFT, see configuration codes under MFT Adjustment Tables (for example, see page 18). Refer to page 53 for customized flows and certified factory calibration flows. Options (add to list price) LF24-MFT-S US Built-in aux. switch (-S) Pg 19 *1/2 body has two different disc sizes (.50 GPM to 1 GPM) (1.5 GPM to 5.5 GPM) **1 body has two different disc sizes (11 GPM to 16 GPM) (17 GPM to 19 GPM) 9

10 P2 Series Pressure Independent Characterized Control Valve with MFT, Non-Spring Return Actuator Two-way Valve with Chrome Plated Brass Ball and Brass Stem with P/T ports, NPT Female Ends Service: Flow Characteristic: Media Temp Range: Ambient Temp Range: Differential Pressure Across Valve Range ( P): chilled or hot water, 60% glycol equal percentage 0 F to 212 F [-18 C to 100 C] -22 F to 122 F [-30 C to 50 C] 5 to 50 psid Maximum Flow Setting: Manual Field Adjustable LRB24-3 Actuators PC Tool Field Adjustable MFT Actuators ARX P2 Pressure Independent Characterized Control Valve, Chrome Plated Brass Ball and Brass Stem, P/T ports 10 Va l v e Non-Spring Return Actuator M o d e l Va l v e Floating Proportional/MFT # F l ow Rate Nominal Size C l o s e - P I C C V L i t e r / D N O f f LRB24-3 LRX24-MFT Va l v e G P M s e c I n ch e s m m p s i ARX24-MFT PICCV PT* / Pg 12 Pg 13 PICCV PT* / Pg 12 Pg 13 PICCV PT* / Pg 12 Pg 13 PICCV PT* / Pg 12 Pg 13 PICCV PT* / Pg 12 Pg 13 PICCV PT* / Pg 12 Pg 13 PICCV PT* / Pg 12 Pg 13 PICCV PT / Pg 12 Pg 13 PICCV PT / Pg 12 Pg 13 PICCV PT / Pg 12 Pg 13 PICCV PT / Pg 12 Pg 13 PICCV PT / Pg 12 Pg 13 PICCV PT** Pg 12 Pg 13 PICCV PT** Pg 12 Pg 13 PICCV PT** Pg 12 Pg 13 PICCV PT** Pg 12 Pg 13 PICCV PT / Pg 23 PICCV PT / Pg 23 PICCV PT / Pg 23 PICCV PT / Pg 23 PICCV PT / Pg 23 PICCV PT / Pg 23 PICCV PT / Pg 23 PICCV PT / Pg 23 PICCV PT / Pg 23 PICCV PT Pg 23 PICCV PT Pg 23 PICCV PT Pg 23 PICCV PT Pg 31 PICCV PT Pg 31 PICCV PT Pg 31 PICCV PT Pg 31 PICCV PT Pg 31 PICCV PT Pg 31 PICCV PT Pg 31 PICCV PT Pg 31 PICCV PT Pg 31 PICCV PT Pg 31 PICCV PT Pg 31 Electrical 3 ft cable 3 ft cable Connection 1/2 conduit fitting 1/2 conduit fitting When ordering MFT, see configuration codes under MFT Adjustment Tables (for example, see page 14). Note: FlowSetR only available on (-3) actuator. Refer to page 53 for customized flows and certified factory calibration flows. Options (add to list price) LRB24-3-S Built-in aux. switch (-S) Pg 12 *1/2 body has two different disc sizes (.50 GPM to 1 GPM) (1.5 GPM to 5.5 GPM) **1 body has two different disc sizes (11 GPM to 16 GPM) (17 GPM to 19 GPM)

11 P2 Series Pressure Independent Characterized Control Valve with MFT, Spring Return Actuator Two-way Valve with Chrome Plated Brass Ball and Brass Stem with P/T ports, NPT Female Ends Service: Flow Characteristic: Media Temp Range: Ambient Temp Range: Differential Pressure Across Valve Range ( P): chilled or hot water, 60% glycol equal percentage 0 F to 212 F [-18 C to 100 C] -22 F to 122 F [-30 C to 50 C] 5 to 50 psid Maximum Flow Setting: PC Tool Field Adjustable MFT Actuators AF P2 Pressure Independent Characterized Control Valve, Chrome Plated Brass Ball and Brass Stem, P/T ports Va l v e Spring Return Actuator M o d e l Va l v e Proportional/MFT # F l ow Rate Nominal Size C l o s e - P I C C V L i t e r / D N O f f TF24-MFT US LF24-MFT US Va l v e G P M s e c I n ch e s m m p s i AF24-MFT US PICCV PT* / Pg 17 Pg 19 PICCV PT* / Pg 17 Pg 19 PICCV PT* / Pg 17 Pg 19 PICCV PT* / Pg 17 Pg 19 PICCV PT* / Pg 17 Pg 19 PICCV PT* / Pg 17 Pg 19 PICCV PT* / Pg 17 Pg 19 PICCV PT / Pg 19 PICCV PT / Pg 19 PICCV PT / Pg 19 PICCV PT / Pg 19 PICCV PT / Pg 19 PICCV PT** Pg 19 PICCV PT** Pg 19 PICCV PT** Pg 19 PICCV PT** Pg 19 PICCV PT / Pg 27 PICCV PT / Pg 27 PICCV PT / Pg 27 PICCV PT / Pg 27 PICCV PT / Pg 27 PICCV PT / Pg 27 PICCV PT / Pg 27 PICCV PT / Pg 27 PICCV PT / Pg 27 PICCV PT Pg 27 PICCV PT Pg 27 PICCV PT Pg 27 PICCV PT Pg 33 PICCV PT Pg 33 PICCV PT Pg 33 PICCV PT Pg 33 PICCV PT Pg 33 PICCV PT Pg 33 PICCV PT Pg 33 PICCV PT Pg 33 PICCV PT Pg 33 PICCV PT Pg 33 PICCV PT Pg 33 Electrical 3 ft cable 3 ft cable Connection 1/2 conduit fitting 1/2 conduit fitting When ordering MFT, see configuration codes under MFT Adjustment Tables (for example, see page 18). Refer to page 53 for customized flows and certified factory calibration flows. Options (add to list price) LF24-MFT-S US AF24-MFT-S US Built-in aux. switch (-S) Pg 19 Pg 27 & 33 *1/2 body has two different disc sizes (.50 GPM to 1 GPM) (1.5 GPM to 5.5 GPM) **1 body has two different disc sizes (11 GPM to 16 GPM) (17 GPM to 19 GPM) 11

12 Pressure Independent Characterized Control Valve with Floating, Non-Spring Return Actuator, P/T Ports (Optional) A p p l i c a t i o n : The Pressure Independent Chara c t e ri zed Control Va l ve is typically used in air handling units on heating and cooling coils and fan coil unit heating or cooling coils. Some other common applications include unit ventilators and VAV re-heat coils. This va l ve is suitabl e for use in a hydronic system with constant or va ri a ble flow. Valve Specifications S e rv i c e chilled or hot wa t e r, 60% glycol F l ow chara c t e ri s t i c equal percentage S i ze 1/2, 3/4, 1 Type of end fitting fe m a l e, NPT M a t e ri a l s : B o d y forged bra s s, nickel plated B a l l chrome plated bra s s S t e m chrome plated bra s s Seat O-ri n g s V i t o n S e a t fiberglass reinforced teflon PTFE C h a ra c t e rizing disc T E F Z E L Pa ck i n g 2 EPDM O-ri n g s, lubri c a t e d D i a p h ra g m p o l yester reinforced silicone Regulator components stainless steel/bra s s / D e l rin 500 AF S p ri n g stainless steel Pe t e s Plugs* (Qty 2) 1 / 4 b ra s s / N o rtel (Optional-P/T) Body pressure ra t i n g 600 PSI Media temp. ra n g e 0 F to 212 F [-18 C to 100 C] Close off pressure 200 PSI L e a k a g e ANSI Class IV (0.01% of rated va l ve capacity at 50 psi diffe r e n t i a l ) F l ow rate 1/2 0.5 GPM [.03 l/s], 1 GPM [.06 l/s], 1.50 GPM [0.09 l/s], 2 GPM [.13 l/s], 3 GPM [.19 l/s], 4 GPM [.25 l/s], 5 GPM [.32 l/s] F l ow rate 3/4 6 GPM [0.37 l/s], 7 GPM [0.44 l/s], 8 GPM [0.50 l/s], 9 GPM [0.57 l/s], 10 GPM [0.63 l/s] F l ow rate 1 12 GPM [0.76 l/s], 14 GPM [0.88 l/s], 16 GPM [1.01 l/s], 18 GPM [1.14 l/s] R a n g e a b i l i t y 100 : 1 D i f ferential pressure 5 to 50 PSI o p e rating ra n g e F l ow accuracy (absolute) ± 5% (5 to 50 PSI) Va riation due to ± 5% (5 to 50 PSI) m a nu fa c t u ring tolera n c e s Hysteresis (absolute) 1% Weight of va l ve body 1 / 2 = 2.52 lbs 3 / 4 = 3.05 lbs 1 = 4.98 lbs Te f zel and Teflon are registered tra d e m a rks of Dupont Actuator Specifications LRB24-3 on/off-floating Power Supply 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% Power Consumption 1.5 W (0.2 W) Transformer Sizing 3 VA (Class 2 power source) Electrical Connection 3 ft, 18 GA plenum rated cable 3 ft, 18 GA appliance rated cable (-S) 1/2 conduit connector Overload Protection electronic throughout 0 to 95 rotation Control on/off, floating point Input Impedance 600 Direction of Rotation reversible with switch Position Indication handle Manual Override external push button and handle Running Time 95 seconds, constant independent of load Humidity 5 to 95% RH non condensing (EN ) Ambient Temperature -22 F to +122 F [-30 C to +50 C] Storage Temperature -40 F to +176 F [-40 C to +80 C] Housing NEMA 2/IP54 Housing Material UL94-5VA Agency Listings culus acc. to UL A/-2-14, CAN/CSA E , CSA C22.2 No , CE acc. to 89/336/EEC and (-S Models) 2006/95/EC Noise Level <35dB(A) Servicing maintenance free Quality Standard ISO 9001 Weight 1.1lbs [0.5 Kg], LRB24-3-S Auxiliary switch 1 x SPDT, 3A (0.5A 250 VAC Weight of actuator 1.4 lbs [0.64 Kg] Rated Impulse Voltage 800V, Type of action 1, (1.B for -S version), Control Pollution Degree 3. 12

13 Pressure Independent Characterized Control Valve with MFT, Non-Spring Return Actuator, P/T Ports (Optional) A p p l i c a t i o n : The Pressure Independent Chara c t e ri zed Control Va l ve is typically used in air handling units on heating and cooling coils and fan coil unit heating or cooling coils. Some other common applications include unit ventilators and VAV re-heat coils. This va l ve is suitabl e for use in a hydronic system with constant or va ri a ble flow. This valve is designed with MFT functionality which facilitates the use of various control input. Valve Specifications S e rv i c e chilled or hot wa t e r, 60% glycol F l ow chara c t e ri s t i c equal percentage S i ze 1/2, 3/4, 1 Type of end fitting fe m a l e, NPT M a t e ri a l s : B o d y forged bra s s, nickel plated B a l l chrome plated bra s s S t e m chrome plated bra s s Seat O-ri n g s V i t o n S e a t fiberglass reinforced teflon PTFE C h a ra c t e rizing disc T E F Z E L Pa ck i n g 2 EPDM O-ri n g s, lubri c a t e d D i a p h ra g m p o l yester reinforced silicone Regulator components stainless steel/bra s s / D e l rin 500 AF S p ri n g stainless steel Pe t e s Plugs* (Qty 2) 1 / 4 b ra s s / N o rtel (Optional-P/T) Body pressure ra t i n g 600 PSI Media temp. ra n g e 0 F to 212 F [-18 C to 100 C] Close off pressure 200 PSI L e a k a g e ANSI Class IV (0.01% of rated va l ve capacity at 50 psi diffe r e n t i a l ) F l ow rate 1/2 0.5 GPM [.03 l/s], 1 GPM [.06 l/s], 1.50 GPM [0.09 l/s], 2 GPM [.13 l/s], 3 GPM [.19 l/s], 4 GPM [.25 l/s], 5 GPM [.32 l/s] F l ow rate 3/4 6 GPM [0.37 l/s], 7 GPM [0.44 l/s], 8 GPM [0.50 l/s], 9 GPM [0.57 l/s], 10 GPM [0.63 l/s] F l ow rate 1 12 GPM [0.76 l/s], 14 GPM [0.88 l/s], 16 GPM [1.01 l/s], 18 GPM [1.14 l/s] R a n g e a b i l i t y 100 : 1 D i f ferential pressure 5 to 50 PSI o p e rating ra n g e F l ow accuracy (absolute) ± 5% (5 to 50 PSI) Va riation due to ± 5% (5 to 50 PSI) m a nu fa c t u ring tolera n c e s Hysteresis (absolute) 1% Weight of va l ve body 1 / 2 = 2.52 lbs 3 / 4 = 3.05 lbs 1 = 4.98 lbs Te f zel and Teflon are registered tra d e m a rks of Dupont Actuator Specifications LRX24-MFT Power Supply 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% Power Consumption 2 W (1.2 W) Transformer Sizing 3.5 VA (Class 2 power source) Electrical Connection Overload Protection Operating Range Y 18 GA plenum rated cable 1/2 conduit connector 3 ft [1m] 10 ft [3m] 16 ft [5m] electronic throughout 0 to 95 rotation 2 to 10 VDC, 4 to 20 ma (default) Va ri a ble (VDC, PWM, Floating Po i n t, O n / O f f ) Input Impedance 100k (0.1 ma), (PWM, Floating Po i n t, On/Off) Feedback Output U 2 to 10 Vdc, 0.5mA max VDC Variable Torque 45 in-lb [5 Nm] Direction of Rotation reversible with switch Position Indication reflective visual indicator (snap-on) Manual Override external push button Running Time Motor* 100 sec constant Humidity 5 to 95% RH non condensing (EN ) Ambient Temperature Storage Temperature Housing Housing Material Agency Listings Noise Level Servicing -22 F to +122 F [-30 C to +50 C] -40 F to +176 F [-40 C to +80 C] NEMA 2/IP54 UL94-5VA culus acc. to UL A/-2-14, CAN/CSA E , CSA C22.2 No , CE acc. to 89/336/EEC <35dB(A) maintenance free Quality Standard ISO 9001 Weight 1.10 lbs [0.50 kg] * P I C CV/LRX24-MFT must remain at 100 sec constant run time Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3. 13

14 Pressure Independent Characterized Control Valve with MFT, Non-Spring Return Actuator, P/T Ports (Optional) 1/2, GPM The PICCV has a unique feature in that the GPM can be adjusted by adjusting the minimum and maximum settings. Selecting the Proper Flow Rate: The PICCV (-PT) can be ordered in 0.50 GPM or 1.0 GPM flow rates. The PICCV (-PT) can be ordered in 1.5 GPM to 5.5 GPM flow rate increments, as stated in the table below. If you wish to re-program to the values listed in the table below : Example 1: The application requires a 2 GPM flow rate. Solution: Order the PICCV Example 2: The application requires a 3.5 GPM flow rate. S o l u t i o n : Order the PICCV and re-program to the below setting for 3.5 GPM. As a standard, the PICCV is available in flows of 4 GPM and 3 GPM. If you desire 3.5 GPM and have a Normally Closed (NC) valve, simply reprogram the maximum setting to 71%, and minimum setting of 0% as indicated on the chart below. MFT Adjustment Table NC will open as voltage increases (no flow at 0-2V) - actuator switch on Y2 Default* Flow Adjustable** Flow rate Flow rate MFT angle of MFT angle of Product Range GPM l/s GPM l/s rotation max. setting rotation min. setting PICCV (-PT) + LRX24-MFT % 0% NEW PICCV (-PT) + LRX24-MFT % 0% NEW PICCV (-PT) + LRX24-MFT % 0% PICCV (-PT) + LRX24-MFT % 0% PICCV (-PT) + LRX24-MFT % 0% PICCV (-PT) + LRX24-MFT % 0% % 0% PICCV (-PT) + LRX24-MFT % 0% % 0% PICCV (-PT) + LRX24-MFT % 0% % 0% PICCV (-PT) + LRX24-MFT % 0% % 0% MFT Adjustment Table NO will close as voltage increases (no flow at 10V) - actuator switch on Y1 Default* Flow Adjustable** Flow rate Flow rate MFT angle of MFT angle of Product Range GPM l/s GPM l/s rotation max. setting rotation min. setting PICCV (-PT) + LRX24-MFT % 33% NEW PICCV (-PT) + LRX24-MFT % 12% NEW PICCV (-PT) + LRX24-MFT % 55% PICCV (-PT) + LRX24-MFT % 37% PICCV (-PT) + LRX24-MFT % 43% PICCV (-PT) + LRX24-MFT % 40% % 37% PICCV (-PT) + LRX24-MFT % 35% % 32% PICCV (-PT) + LRX24-MFT % 28% % 25% PICCV (-PT) + LRX24-MFT % 20% % 18% *Preprogrammed at factory **Customer reprogrammable using MFT PC tool / or can be factory set. Note: 1/2 valve has 2 disc sizes (.5 to 1 GPM) (1.5 to 5.5 GPM) For replacement or re-programming, please contact Technical Support Multi-Function Technology 14 Please note that the settings are different for Normally Closed (NC) and Normally Open (NO) operation. When ordering, please specify NO or NC operation. Selecting the Proper Control Signal Select one of the MFT codes below for the signal required. Example: A 3 GPM flow rate is required, non-spring return actuator, 2-10 VDC signal. Solution: PICCV LRX24-MFT + P Engineering Note: The 1/2 PICCV utilizes two uniquely engineered va l ve bodies to achieve the listed flow rate offe ri n g s. Va ri a ble GPMs are further realized using Belimo s registered Multi- Function Te c h n o l o g y. The PICCV offers nominal flow rates that are adjustable from 0.5 to 1.0 GPM. The PICCV o f fers nominal flow rates that are adjustable from 1.5 to 5.5 GPM ra n g e. Please fo l l ow MFT guideline settings when configuring the PICCV MFT actuators in the field. For complete technical information and list of configuration codes refer to Product Documentation Multi-Function Technology For Damper and Control Valve Applications Model Control Input Running Time Built-in Feedback List Price P VDC VDC No Charge P VDC VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P Floating Point VDC No Charge P-10019* On/Off VDC No Charge E x a m p l e : LRX24-MFT is the basic model. Add the P pre-set MFT configuration number and list price to the actuator when ordering, as needed. Note: Most popular configurations available at no additional cost. All other configurations carry a $30.00 list price. *Please Note: For On/Off control input, please order P and wire as on/off.

15 Pressure Independent Characterized Control Valve with MFT, Non-Spring Return Actuator, P/T Ports (Optional) 3/4, 6 10 GPM The PICCV has a unique feature in that the GPM can be adjusted by adjusting the minimum and maximum settings. Selecting the Proper Flow Rate: The PICCV (-PT) can be ordered in 6 GPM to 10 GPM flow rate increments, as stated in the table below. If you wish to re-program to the values listed in the table below : Example 1: The application requires a 6 GPM flow rate. Solution: Order the PICCV Example 2: The application requires a 8.5 GPM flow rate. S o l u t i o n : Order the PICCV and re-program to the b e l ow setting for 8.5 GPM. As a standard, the PICCV is ava i l a ble in flows of 8 GPM and 9 GPM. If you desire 8.5 GPM and have a Normally Closed (NC) va l ve, simply reprogram the maximum setting to 82%, and minimum setting of 0% as indicated on the chart below. Please note that the settings are different for Normally Closed (NC) and Normally Open (NO) operation. When ordering, please specify NO or NC operation. Selecting the Proper Control Signal Select one of the MFT codes below for the signal required. Example: A 6 GPM flow rate is required, non-spring return actuator, 2-10 VDC signal. Solution: PICCV LRX24-MFT + P Engineering Note: The 3/4 PICCV utilizes a uniquely engineered va l ve body to achieve the listed flow rate offe ri n g s. Va ri a ble GPMs are further realized using Belimo s registered Multi-Function Te c h n o l o g y. The PICCV offers nominal f l ow rates that are adjustable from 6 to 10 GPM. Please fo l l ow MFT guideline settings when configuring the PICCV MFT actuators in the field. MFT Adjustment Table NC will open as voltage increases (no flow at 0-2V) - actuator switch on Y 2 Default* Flow Adjustable** Flow rate Flow rate MFT angle of MFT angle of Product Range GPM l/s GPM l/s rotation max. setting rotation min. setting PICCV (-PT) + LRX24-MFT % 0% % 0% PICCV (-PT) + LRX24-MFT % 0% % 0% PICCV (-PT) + LRX24-MFT % 0% % 0% PICCV (-PT) + LRX24-MFT % 0% % 0% PICCV (-PT) + LRX24-MFT % 0% MFT Adjustment Table NO will close as voltage increases (no flow at 10V) - actuator switch on Y 1 Default* Flow Adjustable** Flow rate Flow rate MFT angle of MFT angle of Product Range GPM l/s GPM l/s rotation max. setting rotation min. setting PICCV (-PT) + LRX24-MFT % 31% % 28% PICCV (-PT) + LRX24-MFT % 27% % 25% PICCV (-PT) + LRX24-MFT % 24% % 22% PICCV (-PT) + LRX24-MFT % 19% % 18% PICCV (-PT) + LRX24-MFT % 13% *Preprogrammed at factory **Customer reprogrammable using MFT PC tool / or can be factory set. Multi-Function Technology For complete technical information and list of configuration codes refer to Product Documentation Multi-Function Technology For Damper and Control Valve Applications Model Control Input Running Time Built-in Feedback List Price P VDC VDC No Charge P VDC VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P Floating Point VDC No Charge P-10019* On/Off VDC No Charge E x a m p l e : LRX24-MFT is the basic model. Add the P pre-set MFT configuration number and list price to the actuator when ordering, as needed. Note: Most popular configurations available at no additional cost. All other configurations carry a $30.00 list price. *Please Note: For On/Off control input, please order P and wire as on/off. 15

16 Pressure Independent Characterized Control Valve with MFT, Non-Spring Return Actuator, P/T Ports (Optional) 1, GPM The PICCV has a unique feature in that the GPM can be adjusted by adjusting the minimum and maximum settings. Selecting the Proper Flow Rate: The PICCV can be ordered in 2 ways. The PICCV can be reprogrammed to offer flows from 11 GPM 16 GPM. Example 1: The application requires a 14 GPM flow rate. Solution: Order the PICCV Example 2: The application requires a 15 GPM flow rate. S o l u t i o n : Order the PICCV and re-program to the b e l ow setting for 15 GPM. As a standard, the PICCV is ava i l a ble in flows of 14 GPM and 16 G P M. If you desire 15 GPM and have a Norm a l l y Closed (NC) va l ve, simply reprogram the maximu m setting to 83%, and minimum setting of 0% as indicated on the chart below. Please note that the settings are different for Normally Closed (NC) and Normally Open (NO) operation. When ordering, please specify NO or NC operation. Selecting the Proper Control Signal Select one of the MFT codes below for the signal required. Example: A 14 GPM flow rate is required, non-spring return actuator, 2-10 VDC signal. Solution: PICCV LRX24-MFT+ P Engineering Note: The 1 PICCV utilizes two uniquely engineered va l ve bodies to achieve the listed flow rate offe ri n g s. Va ri a bl e GPMs are further realized using Belimo s registered Multi-Function Te c h n o l o g y. The PICCV offers nominal flow rates that are adjustable from 11 to 16 GPM. The PICCV offers nominal flow rates that are adjustable from 17 to 19 GPM ra n g e. Please fo l l ow MFT guideline settings when configuring the PICCV MFT actuators in the field. MFT Adjustment Table NC will open as voltage increases (no flow at 0-2V) - actuator switch on Y 2 Default* Flow Adjustable** Flow rate Flow rate MFT angle of MFT angle of Product Range GPM l/s GPM l/s rotation max. setting rotation min. setting % 0% PICCV (-PT) + LRX24-MFT % 0% % 0% PICCV (-PT) + LRX24-MFT % 0% % 0% PICCV (-PT) + LRX24-MFT % 0% PICCV (-PT)+ LRX24-MFT % 0% % 0% % 0% MFT Adjustment Table NO will close as voltage increases (no flow at 10V) - actuator switch on Y 1 Default* Flow Adjustable** Flow rate Flow rate MFT angle of MFT angle of Product Range GPM l/s GPM l/s rotation max. setting rotation min. setting % 26% PICCV (-PT) + LRX24-MFT % 24% % 20% PICCV (-PT) + LRX24-MFT % 16% % 9% PICCV (-PT) + LRX24-MFT % 0% PICCV (-PT) + LRX24-MFT % 22% % 15% % 11% *Preprogrammed at factory **Customer reprogrammable using MFT PC tool / or can be factory set. 1 valve has 2 disc sizes (11 GPM to 16 GPM) (17 GPM to 19 GPM) Multi-Function Technology Model Control Input Running Time Built-in Feedback List Price P VDC VDC No Charge P VDC VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P Floating Point VDC No Charge P-10019* On/Off VDC No Charge E x a m p l e : LRX24-MFT is the basic model. Add the P pre-set MFT configuration number and list price to the actuator when ordering, as needed. Note: Most popular configurations available at no additional cost. All other configurations carry a $30.00 list price. *Please Note: For On/Off control input, please order P and wire as on/off. 16 For complete technical information and list of configuration codes refer to Product Documentation Multi-Function Technology For Damper and Control Valve Applications

17 Pressure Independent Characterized Control Valve with MFT, Spring Return Actuator, P/T Ports (Optional) Valve Specifications S e rv i c e chilled or hot wa t e r, 60% glycol F l ow chara c t e ri s t i c equal percentage S i ze 1 / 2 Type of end fitting fe m a l e, NPT M a t e ri a l s : B o d y forged bra s s, nickel plated B a l l chrome plated bra s s S t e m chrome plated bra s s Seat O-ri n g s V i t o n S e a t fiberglass reinforced teflon PTFE C h a ra c t e rizing disc T E F Z E L Pa ck i n g 2 EPDM O-ri n g s, lubri c a t e d D i a p h ra g m p o l yester reinforced silicone Regulator components stainless steel/bra s s / D e l rin 500 AF S p ri n g stainless steel Pe t e s Plugs* (Qty 2) 1 / 4 b ra s s / N o rtel (Optional-P/T) Body pressure ra t i n g 600 PSI Media temp. ra n g e 0 F to 212 F [-18 C to 100 C] Close off pressure 200 PSI L e a k a g e ANSI Class IV (0.01% of rated va l ve capacity at 50 psi diffe r e n t i a l ) F l ow rate 1/2 0.5 GPM [.03 l/s], 1 GPM [.06 l/s], 1.50 GPM [0.09 l/s], 2 GPM [.13 l/s], 3 GPM [.19 l/s], 4 GPM [.25 l/s], 5 GPM [.32 l/s] R a n g e a b i l i t y 100 : 1 D i f ferential pressure 5 to 50 PSI o p e rating ra n g e F l ow accuracy (absolute) ± 5% (5 to 50 PSI) Va riation due to ± 5% (5 to 50 PSI) m a nu fa c t u ring tolera n c e s Hysteresis (absolute) 1% Weight of va l ve body 1 / 2 = 2.52 lbs 3 / 4 = 3.05 lbs 1 = 4.98 lbs Te f zel and Teflon are registered tra d e m a rks of Dupont A p p l i c a t i o n : The Pressure Independent Chara c t e ri zed Control Va l ve is typically used in air handling units on heating and cooling coils and fan coil unit heating or cooling coils. Some other common applications include unit ventilators and VAV re-heat coils. This va l ve is suitabl e for use in a hydronic system with constant or va ri a ble flow. This valve is designed with MFT functionality which facilitates the use of various control input. Actuator Specifications TF24-MFT US Power supply 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption running: 2.5 W; holding: 1 W Transformer sizing 4 VA (class 2 power source) E l e c t rical connection T F 24 - M F T U S 3 ft, 18 GA plenum rated cabl e 1 / 2 conduit connector O ve rload protection electronic throughout 0 to 95 rotation Operating range Y 2 to 10 V D C 4 to 20 ma (w/500, 1/4 W resistor) ZG- R 01 Input impedance 100k f or 2 to 10 VDC (0.1 ma) 500 f or 4 to 20 ma 1500 f or PWM, Floating point and On-Off control Fe e d b a ck output U 2 to 10 V D C, 0.5 ma max To r q u e min 18 in-lb (2 Nm) Direction of rotation spring: r eve r s i ble with cw/ccw mounting m o t o r: r eve r s i ble with built-in sw i t c h M e c h. angle of rotation max 95, adjust with mechanical stop Running time motor* 100 sec constant Running time spring <25 F to F [-20 C to +50 C] <60 F [-30 C] Angle of Rotation Off (Default) Adaptation Override control Min. (Min Position) = 0% - ZS (Mid. Position) = 50% - M a x. ( M a x. Position) = 100% Position indication visual indicator, 0 to 95 Humidity 5 to 95% RH, non-condensing Ambient temperature -22 to +122 F (-30 to +50 C) Storage temperature -40 to +176 F (-40 to +80 C) Housing NEMA 2, IP42 Housing material UL 94-5VA Noise level Max: <35 db (A) Spring Return <65 db (A) Agency listings culus acc.to UL A/-2-14, CAN/CSA E , CSA C22.2 No.24-93, CE acc. to 89/336/EEC Quality standard ISO 9001 Servicing maintenance free Weight 1.4 lbs. (0.6 kg.) * P I C CV/TF24-MFT US must remain at 100 sec constant run time Rated Impulse Voltage 800V, Type of action 1.AA (1.AA.B for -S version), Control Pollution Degree 3. 17

18 Pressure Independent Characterized Control Valve with MFT, Spring Return Actuator, P/T Ports (Optional) 1/2, GPM The PICCV has a unique feature in that the GPM can be adjusted by adjusting the minimum and maximum settings. Selecting the Proper Flow Rate: The PICCV (-PT) can be ordered in 0.50 GPM or 1.0 GPM flow rates. The PICCV (-PT) can be ordered in 1.5 GPM to 5.5 GPM flow rate increments, as stated in the table below. If you wish to re-program to the values listed in the table below : Example 1: The application requires a 2 GPM flow rate. Solution: Order the PICCV Example 2: The application requires a 3.5 GPM flow rate. S o l u t i o n : Order the PICCV and re-program to the b e l ow setting for 3.5 GPM. As a standard, the PICCV is ava i l a ble in flows of 4 GPM and 3 GPM. If you desire 3.5 GPM and have a Norm a l l y Closed, Fail Open (NC, FO) va l ve, simply reprogram the maximum setting to 75%, and minimum setting of 0% as indicated on the chart below. Please note that the settings are different for Normally Closed, Fail Open or Fail Closed (NC, FO or FC) and Normally Open, Fail Open or Fail Closed (NO, FO or FC) operation. When ordering, please specify NO or NC operation. Selecting the Proper Control Signal Select one of the MFT codes below for the signal required. Example: A 3 GPM flow rate is required, spring return actuator, 2-10 VDC signal. Solution: PICCV TF24-MFT US + P Engineering Note: The 1/2 PICCV utilizes two uniquely engineered va l ve bodies to achieve the listed flow rate offe ri n g s. Va ri a ble GPMs are further realized using Belimo s registered Multi- Function Te c h n o l o g y. The PICCV offers nominal flow ra t e s that are adjustable from 0.5 to 1.0 GPM. The PICCV offe r s nominal flow rates that are adjustable from 1.5 to 5.5 GPM ra n g e. Please fo l l ow MFT guideline settings when configuring the PICCV MFT actuators in the field. MFT Adjustment Table NC will open as voltage increases (no flow at 0-2V) - actuator switch on W Default* Flow Adjustments** MFT angle of MFT angle of Flow rate Flow rate rotation max. setting rotation min. setting Product Range GPM l/s GPM l/s MFT angle of rotation values are subject to change. PICCV (-PT)+ TF24-MFT US FO 80%, FC 73% FO, FC 0% PICCV (-PT) + TF24-MFT US FO 94%, FC 90% FO, FC 0% PICCV (-PT)+ TF24-MFT US FO 62%, FC 58% FO, FC 0% PICCV (-PT) + TF24-MFT US FO 66%, FC 62% FO, FC 0% FO 69%, FC 65% FO, FC 0% PICCV (-PT) + TF24-MFT US FO 72%, FC 69% FO, FC 0% FO 75%, FC 71% FO, FC 0% PICCV (-PT) + TF24-MFT US FO 77%, FC 73% FO, FC 0% FO 81%, FC 77% FO, FC 0% PICCV (-PT) + TF24-MFT US FO 85%, FC 81% FO, FC 0% FO 89%, FC 85% FO, FC 0% MFT Adjustment Table NO will close as voltage increases (no flow at 10V) - actuator switch on CW Default* Flow Adjustments** MFT angle of MFT angle of Flow rate Flow rate rotation max. setting rotation min. setting Product Range GPM l/s GPM l/s MFT angle of rotation values are subject to change. PICCV (-PT)+ TF24-MFT US FO, FC 100% FO 29%, FC 34% PICCV (-PT) + TF24-MFT US FO, FC 100% FO 13%, FC 15% PICCV (-PT)+ TF24-MFT US FO, FC 100% FO 43%, FC 47% PICCV (-PT) + TF24-MFT US FO, FC 100% FO 39%, FC 43% FO, FC 100% FO 36%, FC 41% PICCV (-PT) + TF24-MFT US FO, FC 100% FO 34%, FC 38% FO, FC 100% FO 31%, FC 36% PICCV (-PT) + TF24-MFT US FO, FC 100% FO 28%, FC 33% FO, FC 100% FO 25%, FC 29% PICCV (-PT) + TF24-MFT US FO, FC 100% FO 20%, FC 25% FO, FC 100% FO 17%, FC 22% *Preprogrammed at factory **Customer reprogrammable using MFT PC tool / or can be factory set. Note: 1/2 valve has 2 disc sizes (.5 GPM to 1 GPM) (1.5 GPM to 5.5 GPM) Multi-Function Technology Model Control Input Running Time Built-in Feedback List Price P VDC VDC No Charge P VDC VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P Floating Point VDC No Charge P-10019* On/Off VDC No Charge E x a m p l e : TF24-MFT US is the basic model. Add the P pre-set MFT configuration number and list price to the actuator when ordering, as needed. Note: Most popular configurations available at no additional cost. All other configurations carry a $30.00 list price. *Please Note: For On/Off control input, please order P and wire as on/off. 18 For complete technical information and list of configuration codes refer to Product Documentation Multi-Function Technology For Damper and Control Valve Applications

19 Pressure Independent Characterized Control Valve with MFT, Spring Return Actuator, P/T Ports (Optional) A p p l i c a t i o n : The Pressure Independent Chara c t e ri zed Control Va l ve is typically used in air handling units on heating and cooling coils and fan coil unit heating or cooling coils. Some other common applications include unit ventilators and VAV re-heat coils. This va l ve is suitabl e for use in a hydronic system with constant or va ri a ble flow. This valve is designed with MFT functionality which facilitates the use of various control input. Valve Specifications S e rv i c e chilled or hot wa t e r, 60% glycol F l ow chara c t e ri s t i c equal percentage S i ze 1/2, 3/4, 1 Type of end fitting fe m a l e, NPT M a t e ri a l s : B o d y forged bra s s, nickel plated B a l l chrome plated bra s s S t e m chrome plated bra s s Seat O-ri n g s V i t o n S e a t fiberglass reinforced teflon PTFE C h a ra c t e rizing disc T E F Z E L Pa ck i n g 2 EPDM O-ri n g s, lubri c a t e d D i a p h ra g m p o l yester reinforced silicone Regulator components stainless steel/bra s s / D e l rin 500 AF S p ri n g stainless steel Pe t e s Plugs* (Qty 2) 1 / 4 b ra s s / N o rtel (Optional-PT) Body pressure ra t i n g 600 PSI Media temp. ra n g e 0 F to 212 F [-18 C to 100 C] Close off pressure 200 PSI L e a k a g e ANSI Class IV (0.01% of rated va l ve capacity at 50 psi diffe r e n t i a l ) F l ow rate 1/2 0.5 GPM [.03 l/s], 1 GPM [.06 l/s], 1.50 GPM [0.09 l/s], 2 GPM [.13 l/s], 3 GPM [.19 l/s], 4 GPM [.25 l/s], 5 GPM [.32 l/s] F l ow rate 3/4 6 GPM [0.37 l/s], 7 GPM [0.44 l/s], 8 GPM [0.50 l/s], 9 GPM [0.57 l/s], 10 GPM [0.63 l/s] F l ow rate 1 12 GPM [0.76 l/s], 14 GPM [0.88 l/s], 16 GPM [1.01 l/s], 18 GPM [1.14 l/s] R a n g e a b i l i t y 100 : 1 D i f ferential pressure 5 to 50 PSI o p e rating ra n g e F l ow accuracy (absolute) ± 5% (5 to 50 PSI) Va riation due to ± 5% (5 to 50 PSI) m a nu fa c t u ring tolera n c e s Hysteresis (absolute) 1% Weight of va l ve body 1 / 2 = 2.52 lbs, 3/4 = 3.05 lbs 1 = 4.98 lbs Te f zel and Teflon are registered tra d e m a rks of Dupont Actuator Specifications LF24-MFT US C o n t r o l M F T Control signal Y 2 to 10 VDC (Defa u l t ) Power supply 24 VAC ± 20% 50/60 Hz, 24 VDC ± 10% Power consumption 2.5 W running, 1 W holding Transformer sizing 5 VA (Class 2 power source) E l e c t rical c o n n e c t i o n 3 ft, 18 GA, plenum rated cable, O ve rload protection Operating range Input impedance Fe e d b a ck output U Direction of rotation 1/2 conduit electronic throughout 0 to 95 rotation 2 to 10 V D C, 4 to 20 ma (w/500, 1/4 W resistor) ZG- R k f or 2 to 10 VDC (0.1 ma) 500 f or 4 to 20 ma, 1500 f or PWM, Floating point and On-Off control 2 to 10 V D C, 0.5 ma max s p ring return reve r s i ble with CW/CCW m o u n t i n g. Control direction selected by switch: CW=CW with decrease in signal CCW=CCW with a decrease in signal Running time motor* 100 sec constant Running time spring <25 F to F [-20 C to +50 C] <60 F [-30 C] Position indication visual indicator, 0 to 95 Humidity 5 to 95% RH, non-condensing Operating temp. -22 to +122 F (-30 to +50 C) Storage temp. -40 to +176 F (-40 to +80 C) Housing NEMA 2, IP54 Housing material zinc coated metal Noise level Max: <30 db (A) Spring Return <62 db (A) Agency listings U L 87 3 l i s t e d, C E, C S A C22.2 No. 24 c e rt i f i e d Quality standard ISO 9001 Servicing maintenance free LF24-MFT-S US Auxiliary switch 1 SPDT, 3A (0.5A VAC Weight of actuator 3.26 lbs [1.48 Kg] * P I C CV/LF24-MFT US must remain at 100 sec constant run time 19

20 Pressure Independent Characterized Control Valve with MFT, Spring Return Actuator, P/T Ports (Optional) 1/2, GPM The PICCV has a unique feature in that the GPM can be adjusted by adjusting the minimum and maximum settings. Selecting the Proper Flow Rate: The PICCV (-PT) can be ordered in 0.50 GPM or 1.0 GPM flow rates. The PICCV (-PT) can be ordered in 1.5 GPM to 5.5 GPM flow rate increments, as stated in the table below. If you wish to re-program to the values listed in the table below : Example 1: The application requires a 2 GPM flow rate. Solution: Order the PICCV Example 2: The application requires a 3.5 GPM flow rate. S o l u t i o n : Order the PICCV and re-program to the b e l ow setting for 3.5 GPM. As a standard, the PICCV is ava i l a ble in flows of 4 GPM and 3 GPM. If you desire 3.5 GPM and have a Normally Closed (NC) va l ve, simply reprogram the maximum setting to 71%, and minimum setting of 0% as indicated on the chart below. Please note that the settings are different for Normally Closed (NC) and Normally Open (NO) operation. When ordering, please specify NO or NC operation. Selecting the Proper Control Signal Select one of the MFT codes below for the signal required. Example: A 3 GPM flow rate is required, spring return actuator, 2-10 VDC signal. Solution: PICCV LF24-MFT US + P Engineering Note: The 1/2 PICCV utilizes two uniquely engineered va l ve bodies to achieve the listed flow rate offe ri n g s. Va ri a ble GPMs are further realized using Belimo s registered Multi- Function Te c h n o l o g y. The PICCV offers nominal flow ra t e s that are adjustable from 0.5 to 1.3 GPM. The PICCV offe r s nominal flow rates that are adjustable from 1.5 to 5.5 GPM ra n g e. Please fo l l ow MFT guideline settings when configuring the PICCV MFT actuators in the field. MFT Adjustment Table Multi-Function Technology NC will open as voltage increases (no flow at 0-2V) - actuator switch on CW Default* Flow Adjustments** MFT angle of MFT angle of Flow rate Flow rate rotation max. setting rotation min. setting Product Range GPM l/s GPM l/s MFT angle of rotation values are subject to change. PICCV (-PT) + LF24-MFT US FO 72%, FC 68% FO, FC 0% NEW PICCV (-PT) + LF24-MFT US FO 91%, FC 88% FO, FC 0% NEW PICCV (-PT) + LF24-MFT US % 0% PICCV (-PT) + LF24-MFT US % 0% PICCV (-PT) + LF24-MFT US % 0% PICCV PT + LF24-MFT US % 0% % 0% PICCV (-PT) + LF24-MFT US % 0% % 0% PICCV (-PT) + LF24-MFT US % 0% % 0% PICCV (-PT) + LF24-MFT US % 0% % 0% MFT Adjustment Table NO will close as voltage increases (no flow at 10V) - actuator switch on CCW Default* Flow Adjustments** MFT angle of MFT angle of Flow rate Flow rate rotation max. setting rotation min. setting Product Range GPM l/s GPM l/s MFT angle of rotation values are subject to change. PICCV (-PT) + LF24-MFT US FO, FC 100% FO 30%, FC 33% N E W PICCV (-PT) + LF24-MFT US FO, FC 100% FO 11%, FC 15% N E W PICCV (-PT) + LF24-MFT US % 55% PICCV (-PT) + LF24-MFT US % 37% PICCV (-PT) + LF24-MFT US % 43% PICCV (-PT) + LF24-MFT US % 40% % 37% PICCV (-PT) + LF24-MFT US % 35% % 32% PICCV (-PT) + LF24-MFT US % 28% % 25% PICCV (-PT) + LF24-MFT US % 20% % 18% *Preprogrammed at factory **Customer reprogrammable using MFT PC tool / or can be factory set. FO = Fail Open, FC = Fail Closed Note: 1/2 valve has 2 disc sizes (.5 to 1 GPM) (1.5 to 5.5 GPM) For replacement or re-programming, please contact Technical Support For complete technical information and list of configuration codes refer to Product Documentation Multi-Function Technology For Damper and Control Valve Applications Model Control Input Running Time Built-in Feedback List Price P VDC VDC No Charge P VDC VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P Floating Point VDC No Charge P-10019* On/Off VDC No Charge E x a m p l e : LF24-MFT US is the basic model. Add the P pre-set MFT configuration number and list price to the actuator when ordering, as needed. Note: Most popular configurations available at no additional cost. All other configurations carry a $30.00 list price. *Please Note: For On/Off control input, please order P and wire as on/off. 20

21 Pressure Independent Characterized Control Valve with MFT, Spring Return Actuator, P/T Ports (Optional) 3/4, 6 10 GPM The PICCV has a unique feature in that the GPM can be adjusted by adjusting the minimum and maximum settings. Selecting the Proper Flow Rate: The PICCV (-PT) can be ordered in 6 GPM to 10 GPM flow rate increments, as stated in the table below. If you wish to re-program to the values listed in the table below : Example 1: The application requires a 6 GPM flow rate. Solution: Order the PICCV Example 2: The application requires a 8.5 GPM flow rate. S o l u t i o n : Order the PICCV and re-program to the b e l ow setting for 8.5 GPM. As a standard, the PICCV is ava i l a ble in flows of 8 GPM and 9 GPM. If you desire 8.5 GPM and have a Normally Closed (NC) va l ve, simply reprogram the maximum setting to 82% and minimum setting of 0% as indicated on the chart below. Please note that the settings are different for Normally Closed (NC) and Normally Open (NO) operation. When ordering, please specify NO or NC operation. Selecting the Proper Control Signal Select one of the MFT codes below for the signal required. Example: A 6 GPM flow rate is required, spring return actuator, 2-10 VDC signal. Solution: PICCV LF24-MFT US + P Engineering Note: The 3/4 PICCV utilizes a uniquely engineered va l ve body to achieve the listed flow rate offe ri n g s. Va ri a ble GPMs are further realized using Belimo s registered Multi-Function Te c h n o l o g y. The PICCV offers nominal f l ow rates that are adjustable from 6 to 10 GPM. Please fo l l ow MFT guideline settings when configuring the PICCV MFT actuators in the field. MFT Adjustment Table NC will open as voltage increases (no flow at 0-2V) - actuator switch on CW Default* Flow Adjustments** MFT angle of MFT angle of Flow rate Flow rate rotation max. setting rotation min. setting Product Range GPM l/s GPM l/s MFT angle of rotation values are subject to change. PICCV (-PT) + LF24-MFT US % 0% % 0% PICCV (-PT) + LF24-MFT US % 0% % 0% PICCV (-PT) + LF24-MFT US % 0% % 0% PICCV (-PT) + LF24-MFT US % 0% % 0% PICCV (-PT) + LF24-MFT US % 0% MFT Adjustment Table NO will close as voltage increases (no flow at 10V) - actuator switch on CCW Default* Flow Adjustments** MFT angle of MFT angle of Flow rate Flow rate rotation max. setting rotation min. setting Product Range GPM l/s GPM l/s MFT angle of rotation values are subject to change. PICCV (-PT) + LF24-MFT US % 31% % 28% PICCV (-PT) + LF24-MFT US % 27% % 25% PICCV (-PT) + LF24-MFT US % 24% % 22% PICCV (-PT) + LF24-MFT US % 19% % 18% PICCV (-PT) + LF24-MFT US % 13% *Preprogrammed at factory **Customer reprogrammable using MFT PC tool / or can be factory set. Multi-Function Technology For complete technical information and list of configuration codes refer to Product Documentation Multi-Function Technology For Damper and Control Valve Applications Model Control Input Running Time Built-in Feedback List Price P VDC VDC No Charge P VDC VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P Floating Point VDC No Charge P-10019* On/Off VDC No Charge E x a m p l e : LF24-MFT US is the basic model. Add the P pre-set MFT configuration number and list price to the actuator when ordering, as needed. Note: Most popular configurations available at no additional cost. All other configurations carry a $30.00 list price. *Please Note: For On/Off control input, please order P and wire as on/off. 21

22 Pressure Independent Characterized Control Valve with MFT, Spring Return Actuator, P/T Ports (Optional) 1, GPM The PICCV has a unique feature in that the GPM can be adjusted by adjusting the minimum and maximum settings. Selecting the Proper Flow Rate: The PICCV (-PT) can be ordered in 11 GPM to 16 GPM flow increments, as stated in the table below. The PICCV (-PT) can be ordered in 17 GPM to 19 GPM flow rate increments, as stated in the table below. If you wish to re-program to the values listed in the table below : Example 1: The application requires a 14 GPM flow rate. Solution: Order the PICCV Example 2: The application requires a 15 GPM flow rate. S o l u t i o n : Order the PICCV and re-program to the b e l ow setting for 15 GPM. As a standard, the PICCV is ava i l a ble in flows of 14 GPM and 16 GPM. If yo u desire 15 GPM and have a Normally Closed (NC) va l ve, simply reprogram the maximum setting to 83%, and minimum setting of 0% as indicated on the chart below. Please note that the settings are different for Normally Closed (NC) and Normally Open (NO) operation. When ordering, please specify NO or NC operation. Selecting the Proper Control Signal Select one of the MFT codes below for the signal required. Example: A 14 GPM flow rate is required, non-spring return actuator, 2-10 VDC signal. Solution: PICCV LF24-MFT US + P Engineering Note: The 1 PICCV utilizes two uniquely engineered va l ve bodies to achieve the listed flow rate offe ri n g s. Va ri a bl e GPMs are further realized using Belimo s registered Multi-Function Te c h n o l o g y. The PICCV offers nominal flow rates that are adjustable from 11 to 16 GPM. The PICCV offers nominal flow rates that are adjustable from 17 to 19 GPM ra n g e. Please fo l l ow MFT guideline settings when configuring the PICCV MFT actuators in the field. MFT Adjustment Table NC will open as voltage increases (no flow at 0-2V) - actuator switch on CW Default* Flow Adjustments** MFT angle of MFT angle of Flow rate Flow rate rotation max. setting rotation min. setting Product Range GPM l/s GPM l/s MFT angle of rotation values are subject to change % 0% PICCV (-PT) + LF24-MFT US % 0% % 0% PICCV (-PT) + LF24-MFT US % 0% % 0% PICCV (-PT) + LF24-MFT US % 0% PICCV (-PT) + LF24-MFT US % 0% % 0% % 0% MFT Adjustment Table NO will close as voltage increases (no flow at 10V) - actuator switch on CCW Default* Flow Adjustments** MFT angle of MFT angle of Flow rate Flow rate rotation max. setting rotation min. setting Product Range GPM l/s GPM l/s MFT angle of rotation values are subject to change % 26% PICCV (-PT) + LF24-MFT US % 24% % 20% PICCV (-PT) + LF24-MFT US % 16% % 9% PICCV (-PT) + LF24-MFT US % 0% PICCV (-PT) + LF24-MFT US % 22% % 15% % 11% *Preprogrammed at factory **Customer reprogrammable using MFT PC tool / or can be factory set. 1 valve has 2 disc sizes (11 to 16 GPM) (17 to 19 GPM) Multi-Function Technology Model Control Input Running Time Built-in Feedback List Price P VDC VDC No Charge P VDC VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P Floating Point VDC No Charge P-10019* On/Off VDC No Charge E x a m p l e : LF24-MFT US is the basic model. Add the P pre-set MFT configuration number and list price to the actuator when ordering, as needed. Note: Most popular configurations available at no additional cost. All other configurations carry a $30.00 list price. *Please Note: For On/Off control input, please order P and wire as on/off. 22 For complete technical information and list of configuration codes refer to Product Documentation Multi-Function Technology For Damper and Control Valve Applications

23 Pressure Independent Characterized Control Valve with P/T Ports and MFT, Non-Spring Return Actuator A p p l i c a t i o n : The Pressure Independent Chara c t e ri zed Control Va l ve is typically used in air handling units on heating and cooling coils, and fan coil unit heating or cooling coils. Some other common applications include unit ventilators and VAV re-heat coils. This va l ve is suitabl e for use in a hydronic system with constant or va ri a ble flow. This valve is designed with MFT functionality which facilitates the use of various control input. Valve Specifications S e rv i c e chilled or hot wa t e r, 60% glycol F l ow chara c t e ri s t i c equal percentage S i ze 1-1/4, 1-1/2, 2 Type of end fitting M a t e ri a l s : B o d y B a l l S t e m Seat O-ri n g s fe m a l e, NPT forged bra s s, nickel plated chrome plated bra s s chrome plated bra s s V i t o n S e a t fiberglass reinforced teflon PTFE C h a ra c t e rizing disc T E F Z E L Pa ck i n g 2 EPDM O-ri n g s, lubri c a t e d D i a p h ra g m p o l yester reinforced silicone R e g u l a t o r stainless steel/bra s s / D e l rin 500 AF S p ri n g stainless steel Pe t e s Plugs* (Qty 2) Pressure ra t i n g Media temp. ra n g e Close off pressure L e a k a g e F l ow rate 1-1/4 F l ow rate 1-1/2 F l ow rate 2 1 / 4 b ra s s / N o rtel (Standard) 400 PSI 0 F to 212 F [-18 C to 100 C] 200 PSI ANSI Class IV (0.01% of rated va l ve capacity at 50 psi diffe r e n t i a l ) 18 GPM [1.14 l/s], 20 GPM [1.26 l/s], 22 GPM [1.33 l/s], 24 GPM [1.51 l/s], 26 GPM [1.64 l/s] 26 GPM [1.64 l/s], 28 GPM [1.77 l/s], 30 GPM [1.89 l/s], 33 GPM [2.08 l/s] 33 GPM [2.08 l/s], 36 GPM [2.27 l/s], 40 GPM [2.52 l/s] R a n g e a b i l i t y 100 : 1 D i f ferential pressure 5 to 50 PSI ra n g e F l ow accuracy (absolute) ± 5% (5 to 50 PSI) Va riation due to ± 5% (5 to 50 PSI) m a nu fa c t u ring tolera n c e s Hysteresis (absolute) 1% Weight of va l ve body 1-1 / 4 = 8.31 lbs 1-1 / 2 = 7.70 lbs 2 = 9.38 lbs *Consult page 51 and 52 for flow verification data. Te f zel and Teflon are registered tra d e m a rks of Dupont Actuator Specifications ARX24-MFT Power Supply 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% Power Consumption 4 W (1.25 W) Transformer Sizing 6 VA (Class 2 power source) Electrical Connection 18 GA plenum rated cable 1/2 conduit connector 3 ft [1m] 10 ft [3m] 16 ft [5m] Overload Protection electronic throughout 0 to 95 rotation Operating Range Y 2 to 10 VDC, 4 to 20 ma (default) Va ri a ble (VDC, PWM, Floating Po i n t, O n / O f f ) Input Impedance 100 k (0.1 ma), (PWM, Floating P oint, On/Off) Feedback Output U 2 to 10 VDC, 0.5 ma max VDC Variable Direction of Rotation reversible with switch Position Indication handle Manual Override external push button and handle Running Time Motor* 100 sec constant Humidity 5 to 95% RH non condensing (EN ) Ambient Temperature -22 F to +122 F [-30 C to +50 C] Storage Temperature -40 F to +176 F [-40 C to +80 C] Housing NEMA 2/IP54 Housing Material UL94-5VA Agency Listings culus acc. to UL A/-2-14, CAN/CSA E , CSA C22.2 No , CE acc. to 89/336/EEC Noise Level <45dB(A) Servicing maintenance free Quality Standard ISO 9001 Weight of Actuator 2.02 lbs [0.92 kg] *PICCV/ARX24-MFT must remain at 100 sec constant run time Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3. 23

24 Pressure Independent Characterized Control Valve with P/T Ports and MFT, Non-Spring Return Actuator 1-1/4, GPM The PICCV has a unique feature in that the GPM can be adjusted by adjusting the minimum and maximum settings. Selecting the Proper Flow Rate: The PICCV PT can be ordered in 26 GPM to 33 GPM flow rate increments, as stated in the table below. If you wish to re-program to the values listed in the table below : Example 1: The application requires a 22 GPM flow rate. Solution: Order the PICCV PT Example 2: The application requires a 25 GPM flow rate. S o l u t i o n : Order the PICCV PT and re-program to the below setting for 25 GPM. As a standard, the PICCV is available in flows of 18, 20, 22, 24 and 26 GPM. If you desire 25 GPM and have a Normally Closed (NC) valve, simply reprogram the maximum setting to 87%, and minimum setting of 0% as indicated on the chart below. Please note that the settings are different for Normally Closed (NC) and Normally Open (NO) operation. When ordering, please specify NO or NC operation. Selecting the Proper Control Signal Select one of the MFT codes below for the signal required. Example: A 22 GPM flow rate is required, non-spring return actuator, 2-10 VDC signal. Solution: PICCV PT + ARX24-MFT + P Engineering Note: The 1-1/4 PICCV utilizes a uniquely engineered va l ve body to achieve the listed flow rate offe ri n g s. Variable GPMs are further realized using Belimo s registered Multi-Function Technology. Please fo l l ow MFT guideline settings when configuring the PICCV MFT actuators in the field. Note: Minimum and Maximum Settings differ for the ARX24-MFT and AF24-MFT US actuators. MFT Adjustment Table NC will open as voltage increases (no flow at 0-2V) - actuator switch on Y 2 Default* Flow Adjustments** MFT angle of MFT angle of Flow rate Flow rate rotation max. setting rotation min. setting Product Range GPM l/s GPM l/s MFT angle of rotation values are subject to change. PICCV PT + ARX24-MFT % 0% % 0% PICCV PT + ARX24-MFT % 0% % 0% PICCV PT + ARX24-MFT % 0% % 0% PICCV PT + ARX24-MFT % 0% % 0% PICCV PT + ARX24-MFT % 0% MFT Adjustment Table NO will close as voltage increases (no flow at 10V) - actuator switch on Y 1 Default* Flow Adjustments** MFT angle of MFT angle of Flow rate Flow rate rotation max. setting rotation min. setting Product Range GPM l/s GPM l/s MFT angle of rotation values are subject to change. PICCV PT + ARX24-MFT % 25% % 24% PICCV PT + ARX24-MFT % 23% % 22% PICCV PT + ARX24-MFT % 19% % 18% PICCV PT + ARX24-MFT % 17% % 14% PICCV PT + ARX24-MFT % 11% * Preprogrammed at factory ** Customer reprogrammable using MFT PC tool / or can be factory set. Multi-Function Technology For complete technical information and list of configuration codes refer to Product Documentation Multi-Function Technology For Damper and Control Valve Applications Model Control Input Running Time Built-in Feedback List Price P VDC VDC No Charge P VDC VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P Floating Point VDC No Charge P-10019* On/Off VDC No Charge E x a m p l e : ARX24-MFT is the basic model. Add the P pre-set MFT configuration number and list price to the actuator when ordering, as needed. Note: Most popular configurations available at no additional cost. All other configurations carry a $30.00 list price. *Please Note: For On/Off control input, please order P and wire as on/off. 24

25 Pressure Independent Characterized Control Valve with P/T Ports and MFT, Non-Spring Return Actuator 1-1/2, GPM The PICCV has a unique feature in that the GPM can be adjusted by adjusting the minimum and maximum settings. Selecting the Proper Flow Rate: The PICCV PT can be ordered in 26 GPM to 33 GPM flow rate increments, as stated in the table below. If you wish to re-program to the values listed in the table below : Example 1: The application requires a 28 GPM flow rate. Solution: Order the PICCV PT Example 2: The application requires a 31 GPM flow rate. S o l u t i o n : Order the PICCV PT and re-program to the below setting for 31 GPM. As a standard, the PICCV is available in flows of 26, 28, 30, and 33 GPM. If you desire 31 GPM and have a Normally Closed (NC) valve, simply reprogram the maximum setting to 89%, and minimum setting of 0% as indicated on the chart below. Please note that the settings are different for Normally Closed (NC) and Normally Open (NO) operation. When ordering, please specify NO or NC operation. Selecting the Proper Control Signal Select one of the MFT codes below for the signal required. Example: A 26 GPM flow rate is required, non-spring return actuator, 2-10 VDC signal. Solution: PICCV PT + ARX24-MFT + P Engineering Note: The 1-1/2 PICCV utilizes a uniquely engineered va l ve body to achieve the listed flow rate offe ri n g s. Variable GPMs are further realized using Belimo s registered Multi-Function Technology. Please fo l l ow MFT guideline settings when configuring the PICCV MFT actuators in the field. Note: Minimum and Maximum Settings differ for the ARX24-MFT and AF24-MFT US actuators. MFT Adjustment Table NC will open as voltage increases (no flow at 0-2V) - actuator switch on Y 2 Default* Flow Adjustments** MFT angle of MFT angle of Flow rate Flow rate rotation max. setting rotation min. setting Product Range GPM l/s GPM l/s MFT angle of rotation values are subject to change. PICCV PT + ARX24-MFT % 0% % 0% PICCV PT + ARX24-MFT % 0% % 0% PICCV PT + ARX24-MFT % 0% % 0% % 0% PICCV PT + ARX24-MFT % 0% MFT Adjustment Table NO will close as voltage increases (no flow at 10V) - actuator switch on Y 1 Default* Flow Adjustments** MFT angle of MFT angle of Flow rate Flow rate rotation max. setting rotation min. setting Product Range GPM l/s GPM l/s MFT angle of rotation values are subject to change. PICCV PT + ARX24-MFT % 25% % 24% PICCV PT + ARX24-MFT % 22% % 20% PICCV PT + ARX24-MFT % 16% % 12% % 10% PICCV PT + ARX24-MFT % 6% * Preprogrammed at factory ** Customer reprogrammable using MFT PC tool / or can be factory set. Multi-Function Technology For complete technical information and list of configuration codes refer to Product Documentation Multi-Function Technology For Damper and Control Valve Applications Model Control Input Running Time Built-in Feedback List Price P VDC VDC No Charge P VDC VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P Floating Point VDC No Charge P-10019* On/Off VDC No Charge E x a m p l e : ARX24-MFT is the basic model. Add the P pre-set MFT configuration number and list price to the actuator when ordering, as needed. Note: Most popular configurations available at no additional cost. All other configurations carry a $30.00 list price. *Please Note: For On/Off control input, please order P and wire as on/off. 25

26 Pressure Independent Characterized Control Valve with P/T Ports and MFT, Non-Spring Return Actuator 2, GPM The PICCV has a unique feature in that the GPM can be adjusted by adjusting the minimum and maximum settings. Selecting the Proper Flow Rate: The PICCV PT can be ordered in 33 GPM to 40 GPM flow rate increments, as stated in the table below. If you wish to re-program to the values listed in the table below: Example 1: The application requires a 33 GPM flow rate. Solution: Order the PICCV PT Example 2: The application requires a 34 GPM flow rate. Solution: Order the PICCV PT and re-program to the below setting for 34 GPM. As a standard, the PICCV is available in flows of 33 GPM and 36 GPM. If you desire 34 GPM and have a Normally Closed (NC) valve, simply re-program the maximum setting to 79%, and a minimum setting of 0% as indicated on the chart below. Please note that the settings are different for Normally Closed (NC) and Normally Open (NO) operation. When ordering, please specify NO or NC operation. Selecting the Proper Control Signal: Select one of the MFT codes below for the signal required. Example: A 33 GPM, flow rate is required, non-spring return actuator, 2-10 VDC signal. Solution: PICCV PT + ARX24-MFT + P Engineering Note: The 2" PICCV utilizes a uniquely engineered va l ve body to achieve the listed flow rate offe ri n g s. Va ri a ble GPMs are further realized using Belimo s registered Multi-Function Technology. The PICCV PT offe r s nominal flow rates that are adjustable from 33 to 40 GPM. Please fo l l ow MFT guideline settings when configuring the PICCV MFT actuators in the field. Note: Minimum and Maximum Settings differ for the ARX24-MFT and AF24-MFT US actuators. MFT Adjustment Table NC will open as voltage increases (no flow at 0-2V) - actuator switch on Y 2 Default* Flow Adjustments** MFT angle of MFT angle of Flow rate Flow rate rotation max. setting rotation min. setting Product Range GPM l/s GPM l/s MFT angle of rotation values are subject to change. PICCV PT + ARX24-MFT % 0% % 0% % 0% PICCV PT + ARX24-MFT % 0% % 0% % 0% % 0% PICCV PT + ARX24-MFT % 0% MFT Adjustment Table NO will close as voltage increases (no flow at 10V) - actuator switch on Y 1 Default* Flow Adjustments** MFT angle of MFT angle of Flow rate Flow rate rotation max. setting rotation min. setting Product Range GPM l/s GPM l/s MFT angle of rotation values are subject to change. PICCV PT + ARX24-MFT % 23% % 22% % 20% PICCV PT + ARX24-MFT % 19% % 18% % 17% % 16% PICCV PT + ARX24-MFT % 15% *Preprogrammed at factory **Customer reprogrammable using MFT PC tool / or can be factory set. Multi-Function Technology Model Control Input Running Time Built-in Feedback List Price P VDC VDC No Charge P VDC VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P Floating Point VDC No Charge P-10019* On/Off VDC No Charge E x a m p l e : ARX24-MFT is the basic model. Add the P pre-set MFT configuration number and list price to the actuator when ordering, as needed. Note: Most popular configurations available at no additional cost. All other configurations carry a $30.00 list price. *Please Note: For On/Off control input, please order P and wire as on/off. 26 For complete technical information and list of configuration codes refer to Product Documentation Multi-Function Technology For Damper and Control Valve Applications

27 Pressure Independent Characterized Control Valve with P/T Ports and MFT, Spring Return Actuator A p p l i c a t i o n : The Pressure Independent Chara c t e ri zed Control Va l ve is typically used in air handling units on heating and cooling coils, and fan coil unit heating or cooling coils. Some other common applications include unit ventilators and VAV re-heat coils. This va l ve is suitabl e for use in a hydronic system with constant or va ri a ble flow. This valve is designed with MFT functionality which facilitates the use of various control input. Valve Specifications S e rv i c e chilled or hot wa t e r, 60% glycol F l ow chara c t e ri s t i c equal percentage S i ze 1-1/4, 1-1/2, 2 Type of end fitting fe m a l e, NPT M a t e ri a l s : B o d y forged bra s s, nickel plated B a l l chrome plated bra s s S t e m chrome plated bra s s Seat O-ri n g s V i t o n S e a t fiberglass reinforced teflon PTFE C h a ra c t e rizing disc T E F Z E L Pa ck i n g 2 EPDM O-ri n g s, lubri c a t e d D i a p h ra g m p o l yester reinforced silicone R e g u l a t o r stainless steel/bra s s / D e l rin 500 AF S p ri n g stainless steel Pe t e s Plugs* (Qty 2) 1 / 4 b ra s s / N o rtel (Standard) Pressure ra t i n g 400 PSI Media temp. ra n g e 0 F to 212 F [-18 C to 100 C] Close off pressure 200 PSI L e a k a g e ANSI Class IV (0.01% of rated va l ve capacity at 50 psi diffe r e n t i a l ) F l ow rate 1-1/4 18 GPM [1.14 l/s], 20 GPM [1.26 l/s], 22 GPM [1.33 l/s], 24 GPM [1.51 l/s], 26 GPM [1.64 l/s] F l ow rate 1-1/2 26 GPM [1.64 l/s], 28 GPM [1.77 l/s], 30 GPM [1.89 l/s], 33 GPM [2.08 l/s] F l ow rate 2 33 GPM [2.08 l/s], 36 GPM [2.27 l/s], 40 GPM [2.52 l/s] R a n g e a b i l i t y 100 : 1 D i f ferential pressure 5 to 50 PSI ra n g e F l ow accuracy (absolute) ± 5% (5 to 50 PSI) Va riation due to ± 5% (5 to 50 PSI) m a nu fa c t u ring tolera n c e s Hysteresis (absolute) 1% Weight of va l ve body Weight of va l ve body 1-1 / 4 = 8.31 lbs, 1-1/2 = 7.70 lbs 2 = 9.38 lbs *Consult page 51 and 52 for flow verification data. Te f zel and Teflon are registered tra d e m a rks of Dupont Actuator Specifications AF24-MFT US C o n t r o l M F T Control signal: 2 to 10 V D C, (4 to 20 ma with 500 resistor) Power supply 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption: 6 W running, 2.5 W holding Tra n s fo rmer sizing: 10 VA, class 2 powe r E l e c t rical connection: 3 ft, 18 GA appl. c a bl e, 1/2 conduit fit. E l e c t rical protection: Au x. switches double insulated O ve rload protection: electronic throughout rotation Input impedance: 100 K for 2 to 10 VDC (0.1 ma) 500 for 4 to 20 ma 750 for PWM 1500 for on/off and floating point Fe e d b a ck output: 2 to 10 V D C, 0.5 ma max Angle of rotation: 95 Direction of rotation: selected by sw i t c h : CW=CW with decrease signal CCW=CCW with decrease signal S p ring return direction: CW/CCW mounting Position indication: visual indicator M a nual ove r ri d e : h ex crank Running time motor:* 100 sec constant Ambient tempera t u r e : -22 F to 122 F [-30 C to 50 C] H o u s i n g : NEMA 2 / IP54 Agency listings: UL 873, CSA C22.2 N o. 24 certified, CE Noise leve l : m a x. 45 db(a) A F 24 - M F T-S US Au x i l i a ry sw i t c h 2 x SPDT 5 fixed/25 to 85, 7A 250 VAC Weight of actuator 6.28 lbs [2.85 Kg] *PICCV/AF24-MFT US must remain at 100 sec constant run time 27

28 Pressure Independent Characterized Control Valve with P/T Ports and MFT, Spring Return Actuator 1-1/4, GPM The PICCV has a unique feature in that the GPM can be adjusted by adjusting the minimum and maximum settings. Selecting the Proper Flow Rate: The PICCV PT can be ordered in 18 GPM to 26 GPM flow rate increments, as stated in the table below. If you wish to re-program to the values listed in the table below : Example 1: The application requires a 22 GPM flow rate. Solution: Order the PICCV PT Example 2: The application requires a 25 GPM flow rate. S o l u t i o n : Order the PICCV PT and re-program to the below setting for 25 GPM. As a standard, the PICCV is available in flows of 18, 20, 22, 24 and 26 GPM. If you desire 25 GPM and have a Normally Closed (NC) valve, simply reprogram the maximum setting to 87%, and minimum setting of 0% as indicated on the chart below. Please note that the settings are different for Normally Closed (NC) and Normally Open (NO) operation. When ordering, please specify NO or NC operation. Selecting the Proper Control Signal Select one of the MFT codes below for the signal required. Example: A 22 GPM flow rate is required, non-spring return actuator, 2-10 VDC signal. Solution: PICCV PT + AF24-MFT US + P Engineering Note: The 1-1/4 PICCV utilizes a uniquely engineered va l ve body to achieve the listed flow rate offe ri n g s. Variable GPMs are further realized using Belimo s registered Multi-Function Technology. Please fo l l ow MFT guideline settings when configuring the PICCV MFT actuators in the field. Note: Minimum and Maximum Settings differ for the ARX24-MFT and AF24-MFT US actuators. MFT Adjustment Table NC will open as voltage increases (no flow at 0-2V) - actuator switch on CW Default* Flow Adjustments** MFT angle of MFT angle of Flow rate Flow rate rotation max. setting rotation min. setting Product Range GPM l/s GPM l/s MFT angle of rotation values are subject to change. PICCV PT + AF24-MFT US % 0% % 0% PICCV PT + AF24-MFT US % 0% % 0% PICCV PT + AF24-MFT US % 0% % 0% PICCV PT + AF24-MFT US % 0% % 0% PICCV PT + AF24-MFT US % 0% MFT Adjustment Table NO will close as voltage increases (no flow at 10V) - actuator switch on CCW Default* Flow Adjustments** MFT angle of MFT angle of Flow rate Flow rate rotation max. setting rotation min. setting Product Range GPM l/s GPM l/s MFT angle of rotation values are subject to change. PICCV PT + AF24-MFT US % 25% % 24% PICCV PT + AF24-MFT US % 23% % 22% PICCV PT + AF24-MFT US % 19% % 18% PICCV PT + AF24-MFT US % 17% % 14% PICCV PT + AF24-MFT US % 11% * Preprogrammed at factory ** Customer reprogrammable using MFT PC tool / or can be factory set. Multi-Function Technology Model Control Input Running Time Built-in Feedback List Price P VDC VDC No Charge P VDC VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P Floating Point VDC No Charge P-10019* On/Off VDC No Charge E x a m p l e : AF24-MFT US is the basic model. Add the P pre-set MFT configuration number and list price to the actuator when ordering, as needed. Note: Most popular configurations available at no additional cost. All other configurations carry a $30.00 list price. *Please Note: For On/Off control input, please order P and wire as on/off. 28 For complete technical information and list of configuration codes refer to Product Documentation Multi-Function Technology For Damper and Control Valve Applications

29 Pressure Independent Characterized Control Valve with P/T Ports and MFT, Spring Return Actuator 1-1/2, GPM The PICCV has a unique feature in that the GPM can be adjusted by adjusting the minimum and maximum settings. Selecting the Proper Flow Rate: The PICCV PT can be ordered in 26 GPM to 33 GPM flow rate increments, as stated in the table below. If you wish to re-program to the values listed in the table below : Example 1: The application requires a 28 GPM flow rate. Solution: Order the PICCV PT Example 2: The application requires a 31 GPM flow rate. S o l u t i o n : Order the PICCV PT and re-program to the below setting for 31 GPM. As a standard, the PICCV is available in flows of 26, 28, 30, and 33 GPM. If you desire 31 GPM and have a Normally Closed (NC) valve, simply reprogram the maximum setting to 89%, and minimum setting of 0% as indicated on the chart below. Please note that the settings are different for Normally Closed (NC) and Normally Open (NO) operation. When ordering, please specify NO or NC operation. Selecting the Proper Control Signal Select one of the MFT codes below for the signal required. Example: A 26 GPM flow rate is required, non-spring return actuator, 2-10 VDC signal. Solution: PICCV PT + AF24-MFT US + P Engineering Note: The 1-1/2 PICCV utilizes a uniquely engineered va l ve body to achieve the listed flow rate offe ri n g s. Variable GPMs are further realized using Belimo s registered Multi-Function Technology. Please fo l l ow MFT guideline settings when configuring the PICCV MFT actuators in the field. Note: Minimum and Maximum Settings differ for the ARX24-MFT and AF24-MFT US actuators. MFT Adjustment Table NC will open as voltage increases (no flow at 0-2V) - actuator switch on CW Default* Flow Adjustments** MFT angle of MFT angle of Flow rate Flow rate rotation max. setting rotation min. setting Product Range GPM l/s GPM l/s MFT angle of rotation values are subject to change. PICCV PT + AF24-MFT US % 0% % 0% PICCV PT + AF24-MFT US % 0% % 0% PICCV PT + AF24-MFT US % 0% % 0% % 0% PICCV PT + AF24-MFT US % 0% MFT Adjustment Table NO will close as voltage increases (no flow at 10V) - actuator switch on CCW Default* Flow Adjustments** MFT angle of MFT angle of Flow rate Flow rate rotation max. setting rotation min. setting Product Range GPM l/s GPM l/s MFT angle of rotation values are subject to change. PICCV PT + AF24-MFT US % 25% % 24% PICCV PT + AF24-MFT US % 22% % 20% PICCV PT + AF24-MFT US % 16% % 12% % 10% PICCV PT + AF24-MFT US % 6% * Preprogrammed at factory ** Customer reprogrammable using MFT PC tool / or can be factory set. Multi-Function Technology For complete technical information and list of configuration codes refer to Product Documentation Multi-Function Technology For Damper and Control Valve Applications Model Control Input Running Time Built-in Feedback List Price P VDC VDC No Charge P VDC VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P Floating Point VDC No Charge P-10019* On/Off VDC No Charge E x a m p l e : AF24-MFT US is the basic model. Add the P pre-set MFT configuration number and list price to the actuator when ordering, as needed. Note: Most popular configurations available at no additional cost. All other configurations carry a $30.00 list price. *Please Note: For On/Off control input, please order P and wire as on/off. 29

30 Pressure Independent Characterized Control Valve with P/T Ports and MFT, Spring Return Actuator 2, GPM The PICCV has a unique feature in that the GPM can be adjusted by adjusting the minimum and maximum settings. Selecting the Proper Flow Rate: The PICCV PT can be ordered in 33 GPM to 40 GPM flow rate increments, as stated in the table below. If you wish to re-program to the values listed in the table below : Example 1: The application requires a 33 GPM flow rate. Solution: Order the PICCV PT Example 2: The application requires a 34 GPM flow rate. Solution: Order the PICCV PT and re-program to the below setting for 34 GPM. As a standard, the PICCV is available in flows of 33 GPM and 36 GPM. If you desire 34 GPM and have a Normally Closed (NC) valve, simply re-program the maximum setting to 79%, and a minimum setting of 0% as indicated on the chart below. Please note that the settings are different for Normally Closed (NC) and Normally Open (NO) operation. When ordering, please specify NO or NC operation. Selecting the Proper Control Signal: Select one of the MFT codes below for the signal required. Example: A 33 GPM, flow rate is required, non-spring return actuator, 2-10 VDC signal. Solution: PICCV PT + AF24-MFT US + P Engineering Note: The 2" PICCV utilizes a uniquely engineered va l ve body to achieve the listed flow rate offe ri n g s. Va ri a ble GPMs are further realized using Belimo s registered Multi-Function Technology. The PICCV PT offe r s nominal flow rates that are adjustable from 33 to 40 GPM. Please fo l l ow MFT guideline settings when configuring the PICCV MFT actuators in the field. Note: Minimum and Maximum Settings differ for the ARX24-MFT and AF24-MFT US actuators. MFT Adjustment Table NC will open as voltage increases (no flow at 0-2V) - actuator switch on CW Default* Flow Adjustments** MFT angle of MFT angle of Flow rate Flow rate rotation max. setting rotation min. setting Product Range GPM l/s GPM l/s MFT angle of rotation values are subject to change. PICCV PT + AF24-MFT US % 0% % 0% % 0% PICCV PT + AF24-MFT US % 0% % 0% % 0% % 0% PICCV PT + AF24-MFT US % 0% MFT Adjustment Table NO will close as voltage increases (no flow at 10V) - actuator switch on CCW Default* Flow Adjustments** MFT angle of MFT angle of Flow rate Flow rate rotation max. setting rotation min. setting Product Range GPM l/s GPM l/s MFT angle of rotation values are subject to change. PICCV PT + AF24-MFT US % 23% % 22% % 20% PICCV PT + AF24-MFT US % 19% % 18% % 17% % 16% PICCV PT + AF24-MFT US % 15% *Preprogrammed at factory **Customer reprogrammable using MFT PC tool / or can be factory set. Multi-Function Technology Model Control Input Running Time Built-in Feedback List Price P VDC VDC No Charge P VDC VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P Floating Point VDC No Charge P-10019* On/Off VDC No Charge Example:AF24-MFT US is the basic model. Add the P pre-set MFT configuration number and list price to the actuator when ordering, as needed. Note: Most popular configurations available at no additional cost. All other configurations carry a $30.00 list price. *Please Note: For On/Off control input, please order P and wire as on/off. 30 For complete technical information and list of configuration codes refer to Product Documentation Multi-Function Technology For Damper and Control Valve Applications

31 2 Pressure Independent Characterized Control Valve with P/T Ports and MFT, Non-Spring Return Actuator A p p l i c a t i o n : The Pressure Independent Chara c t e ri zed Control Va l ve is typically used in air handling units on heating and cooling coils, and fan coil unit heating or cooling coils. Some other common applications include unit ventilators and VAV re-heat coils. This va l ve is suitabl e for use in a hydronic system with constant or va ri a ble flow. This valve is designed with MFT functionality which facilitates the use of various control input. Valve Specifications S e rv i c e F l ow chara c t e ri s t i c S i ze Type of end fitting M a t e ri a l s : B o d y B a l l S t e m Seat O-ri n g s S e a t s chilled or hot wa t e r, 60% glycol equal percentage 2 (44 GPM to 100 GPM) fe m a l e, NPT C h a ra c t e rizing disc T E F Z E L Pa ck i n g D i a p h ra g m Regulator components S p ri n g Pe t e s Plugs* Qty (2) Body pressure ra t i n g Media temp. ra n g e forged bra s s, nickel plated chrome plated bra s s chrome plated bra s s V i t o n fiberglass reinforced teflon PTFE 2 EPDM O-ri n g s, lubri c a t e d p o l yester reinforced silicone stainless steel/bra s s / D e l rin 500 AF stainless steel 1 / 4 b ra s s / N o rtel (Standard) 400 PSI 0 F to 212 F [-18 C to 100 C] Close off pressure 200 PSI L e a k a g e ANSI Class IV (0.01% of rated va l ve capacity at 50 psi diffe r e n t i a l ) F l ow rate 2 44 GPM [2.78 l/s], 48 GPM [3.03 l/s], 52 GPM [3.28 l/s], 56 GPM [3.53 l/s], 60 GPM [3.79 l/s], 65 GPM [4.10 l/s], 70 GPM [4.42 l/s], 75 GPM [4.73 l/s], 80 GPM [5.05 l/s], 90 GPM [5.68 l/s], 100 GPM [6.31 l/s] R a n g e a b i l i t y 100 : 1 D i f ferential pressure 5 to 50 PSI ra n g e F l ow accuracy (absolute) ± 5% (5 to 50 PSI) Va riation due to ± 5% (5 to 50 PSI) m a nu fa c t u ring tolera n c e s Hysteresis (absolute) 1% Weight of va l ve body 29.1 lbs Actuator Specifications ARX24-MFT Power Supply 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% Power Consumption 4 W (1.25 W) Transformer Sizing 6 VA (Class 2 power source) Electrical Connection 18 GA plenum rated cable 1/2 conduit connector 3 ft [1m] 10 ft [3m] 16 ft [5m] Overload Protection Operating Range Y electronic throughout 0 to 95 rotation 2 to 10 VDC, 4 to 20 ma (default) Va ri a ble (VDC, PWM, Floating Po i n t, O n / O f f ) Input Impedance 100 k (0.1 ma), (PWM, Floating P oint, On/Off) Feedback Output U 2 to 10 VDC, 0.5 ma max VDC Variable Direction of Rotation reversible with switch Position Indication handle Manual Override external push button and handle Running time motor* 100 sec constant Humidity Ambient Temperature Storage Temperature Housing Housing Material 5 to 95% RH non condensing (EN ) -22 F to +122 F [-30 C to +50 C] -40 F to +176 F [-40 C to +80 C] NEMA 2/IP54 UL94-5VA Agency Listings culus acc. to UL A/-2-14, CAN/CSA E , CSA C22.2 No , CE acc. to 89/336/EEC Noise Level <45dB(A) Servicing maintenance free Quality Standard ISO 9001 Weight of actuator 2.02 lbs [0.92 kg] *PICCV/ARX24-MFT US must remain at 100 sec constant run time Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3. Te f zel and Teflon are registered tra d e m a rks of Dupont *Consult page 51 and 52 for flow verification data. 31

32 2 Pressure Independent Characterized Control Valve with P/T Ports and MFT, Non-Spring Return Actuator 2, GPM The PICCV has a unique feature in that the GPM can be adjusted by adjusting the minimum and maximum settings. Selecting the Proper Flow Rate: The PICCV PT can be ordered in 44 GPM to 80 GPM flow rate increments, as stated in the table below. If you wish to re-program to the values listed in the table below: Example 1: The application requires a 50 GPM flow rate, and a Normally Closed valve. Solution: Order the PICCV PT Example 2: The application requires a 56 GPM flow rate. Solution: Order the PICCV PT and re-program to a maximum setting of 87%, and a minimum setting of 0% as indicated on the chart below. Please note that the settings are different for Normally Closed (NC) and Normally Open (NO) operation. When ordering, please specify NO or NC operation. Selecting the Proper Control Signal: Select one of the MFT codes below for the signal required. Example: A 50 GPM, flow rate is required, non-spring return actuator, 2-10 VDC signal. Solution: PICCV PT + ARX24-MFT + P Engineering Note: The 2" PICCV utilizes a uniquely engineered va l ve body to achieve the listed flow rate offe ri n g s. Va ri a ble GPMs are further realized using Belimo s registered Multi-Function Te c h n o l o g y. The PICCV PT offers nominal flow rates that are adjustable from 44 to 80 GPM. P l e a s e fo l l ow MFT guideline settings when configuring the PICCV MFT actuators in the field. Note: Minimum and Maximum Settings differ for the ARX24-MFT and AF24-MFT US actuators. 32 MFT Adjustment Table NC will open as voltage increases (no flow at 0-2V) - actuator switch on Y 2 Default* MFT angle of MFT angle of Flow rate rotation max. setting rotation min. setting Product Range GPM l/s MFT angle of rotation values are subject to change. PICCV PT + ARX24-MFT % 0% PICCV PT + ARX24-MFT % 0% PICCV PT + ARX24-MFT % 0% PICCV PT + ARX24-MFT % 0% PICCV PT + ARX24-MFT % 0% PICCV PT + ARX24-MFT % 0% PICCV PT + ARX24-MFT % 0% PICCV PT + ARX24-MFT % 0% PICCV PT + ARX24-MFT % 0% PICCV PT + ARX24-MFT % 0% PICCV PT + ARX24-MFT % 0% MFT Adjustment Table NO will close as voltage increases (no flow at 10V) - actuator switch on Y 1 Default* MFT angle of MFT angle of Flow rate rotation max. setting rotation min. setting Product Range GPM l/s MFT angle of rotation values are subject to change. PICCV PT + ARX24-MFT % 28% PICCV PT + ARX24-MFT % 26% PICCV PT + ARX24-MFT % 24% PICCV PT + ARX24-MFT % 22% PICCV PT + ARX24-MFT % 20% PICCV PT + ARX24-MFT % 17% PICCV PT + ARX24-MFT % 13% PICCV PT + ARX24-MFT % 10% PICCV PT + ARX24-MFT % 1% PICCV PT + ARX24-MFT % 11% PICCV PT + ARX24-MFT % 0% *Preprogrammed at factory **Customer reprogrammable using MFT PC tool / or can be factory set. Note: 2 valves has 2 disc sizes (44 GPM to 80 GPM) (90 GPM to 100 GPM) Multi-Function Technology For complete technical information and list of configuration codes refer to Product Documentation Multi-Function Technology For Damper and Control Valve Applications Model Control Input Running Time Built-in Feedback List Price P VDC VDC No Charge P VDC VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P Floating Point VDC No Charge P-10019* On/Off VDC No Charge E x a m p l e : ARX24-MFT is the basic model. Add the P pre-set MFT configuration number and list price to the actuator when ordering, as needed. Note: Most popular configurations available at no additional cost. All other configurations carry a $30.00 list price. *Please Note: For On/Off control input, please order P and wire as on/off.

33 2 Pressure Independent Characterized Control Valve with P/T Ports and MFT, Spring Return Actuator A p p l i c a t i o n : The Pressure Independent Chara c t e ri zed Control Va l ve is typically used in air handling units on heating and cooling coils, and fan coil unit heating or cooling coils. Some other common applications include unit ventilators and VAV re-heat coils. This va l ve is suitabl e for use in a hydronic system with constant or va ri a ble flow. This valve is designed with MFT functionality which facilitates the use of various control input. Valve Specifications S e rv i c e chilled or hot wa t e r, 60% glycol F l ow chara c t e ri s t i c equal percentage S i ze 2 (44 GPM GPM) Type of end fitting fe m a l e, NPT M a t e ri a l s : B o d y forged bra s s, nickel plated B a l l chrome plated bra s s S t e m chrome plated bra s s Seat O-ri n g s V i t o n S e a t s fiberglass reinforced teflon PTFE C h a ra c t e rizing disc T E F Z E L Pa ck i n g 2 EPDM O-ri n g s, lubri c a t e d D i a p h ra g m p o l yester reinforced silicone Regulator components stainless steel/bra s s / D e l rin 500 AF S p ri n g stainless steel Pe t e s Plugs* (Qty 2) 1 / 4 b ra s s / N o rtel (Standard) Body pressure ra t i n g 400 PSI Media temp. ra n g e 0 F to 212 F [-18 C to 100 C] Close off pressure 200 PSI L e a k a g e ANSI Class IV (0.01% of rated va l ve capacity at 50 psi diffe r e n t i a l ) F l ow rate 2 44 GPM [2.78 l/s], 48 GPM [3.03 l/s], 52 GPM [3.28 l/s], 56 GPM [3.53 l/s], 60 GPM [3.79 l/s], 65 GPM [4.10 l/s], 70 GPM [4.42 l/s], 75 GPM [4.73 l/s], 80 GPM [5.05 l/s], 90 GPM [5.68 l/s], 100 GPM [6.31 l/s] R a n g e a b i l i t y 100 : 1 D i f ferential pressure 5 to 50 PSI ra n g e F l ow accuracy (absolute) ± 5% (5 to 50 PSI) Va riation due to ± 5% (5 to 50 PSI) m a nu fa c t u ring tolera n c e s Hysteresis (absolute) 1% Weight of va l ve body 29.1 lbs Actuator Specifications AF24-MFT US C o n t r o l M F T Control signal: 2 to 10 V D C, (4 to 20 ma with 500 resistor) Power supply Power consumption: Tra n s fo rmer sizing: E l e c t rical connection: E l e c t rical protection: O ve rload protection: 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% 6 W running, 2.5 W holding 10 VA, class 2 powe r 3 ft, 18 GA appl. c a bl e, 1/2 conduit fit. Au x. switches double insulated electronic throughout rotation Input impedance: 100 K for 2 to 10 VDC (0.1 ma) 500 for 4 to 20 ma 750 for PWM 1500 for on/off and floating point Fe e d b a ck output: 2 to 10 V D C, 0.5 ma max Angle of rotation: 95 Direction of rotation: selected by sw i t c h : CW=CW with decrease signal CCW=CCW with decrease signal S p ring return direction: CW/CCW mounting Position indication: visual indicator M a nual ove r ri d e : h ex crank Au x i l i a ry sw i t c h e s : 2 x SPDT. 5 fixed/25 to 85 (-S) Running time motor:* 100 sec constant Ambient tempera t u r e : -22 F to 122 F [-30 C to 50 C] H o u s i n g : NEMA 2 / IP54 Agency listings: UL 873, CSA C22.2 N o. 24 certified, CE Noise leve l : m a x. 45 db(a) A F 24 - M F T-S US Au x i l i a ry sw i t c h 2 x SPDT 5 fixed/25 to 85, 7A 250 VAC Weight of actuator 6.28 lbs [2.85 Kg] *PICCV/AF24-MFT US must remain at 100 sec constant run time Te f zel and Teflon are registered tra d e m a rks of Dupont *Consult page 51 and 52 for flow verification data. 33

34 2 Pressure Independent Characterized Control Valve with P/T Ports and MFT, Spring Return Actuator 2, GPM The PICCV has a unique feature in that the GPM can be adjusted by adjusting the minimum and maximum settings. Selecting the Proper Flow Rate: The PICCV PT can be ordered in 44 GPM to 80 GPM flow rate increments, as stated in the table below. If you wish to re-program to the values listed in the table below: Example 1: The application requires a 50 GPM flow rate, and a Normally Closed valve. Solution: Order the PICCV PT Example 2: The application requires a 56 GPM flow rate. Solution: Order the PICCV PT and re-program to a maximum setting of 81%, and a minimum setting of 0% as indicated on the chart below. Please note that the settings are different for Normally Closed (NC) and Normally Open (NO) operation. When ordering, please specify NO or NC operation. Selecting the Proper Control Signal: Select one of the MFT codes below for the signal required. Example: A 50 GPM, flow rate is required, spring return actuator, 2-10 VDC signal. Solution: PICCV PT + AF24-MFT US + P Engineering Note: The 2" PICCV utilizes a uniquely engineered va l ve body to achieve the listed flow rate offe ri n g s. Va ri a ble GPMs are further realized using Belimo s registered Multi-Function Te c h n o l o g y. The PICCV PT offers nominal flow rates that are adjustable from 44 to 80 GPM. P l e a s e fo l l ow MFT guideline settings when configuring the PICCV MFT actuators in the field. Note: Minimum and Maximum Settings differ for the ARX24-MFT and AF24-MFT US actuators. 34 MFT Adjustment Table Multi-Function Technology NC will open as voltage increases (no flow at 0-2V) - actuator switch on CW Default* MFT angle of MFT angle of Flow rate rotation max. setting rotation min. setting Product Range GPM l/s MFT angle of rotation values are subject to change. PICCV PT + AF24-MFT US % 0% PICCV PT + AF24-MFT US % 0% PICCV PT + AF24-MFT US % 0% PICCV PT + AF24-MFT US % 0% PICCV PT + AF24-MFT US % 0% PICCV PT + AF24-MFT US % 0% PICCV PT + AF24-MFT US % 0% PICCV PT + AF24-MFT US % 0% PICCV PT + AF24-MFT US % 0% PICCV PT + AF24-MFT US FO 93%, FC 89% FO, FC 0% PICCV PT + AF24-MFT US FO, FC 100% FO, FC 0% MFT Adjustment Table NO will close as voltage increases (no flow at 10V) - actuator switch on CCW Default* MFT angle of MFT angle of Flow rate rotation max. setting rotation min. setting Product Range GPM l/s MFT angle of rotation values are subject to change. PICCV PT + AF24-MFT US % 24% PICCV PT + AF24-MFT US % 22% PICCV PT + AF24-MFT US % 21% PICCV PT + AF24-MFT US % 19% PICCV PT + AF24-MFT US % 17% PICCV PT + AF24-MFT US % 13% PICCV PT + AF24-MFT US % 11% PICCV PT + AF24-MFT US % 2% PICCV PT + AF24-MFT US % 0% PICCV PT + AF24-MFT US FO, FC 100% FO 12%, FC 16% PICCV PT + AF24-MFT US FO, FC 100% FO, FC 0% *Preprogrammed at factory **Customer reprogrammable using MFT PC tool / or can be factory set. Note: 2 valves has 2 disc sizes (44 GPM to 80 GPM) (90 GPM to 100 GPM) For complete technical information and list of configuration codes refer to Product Documentation Multi-Function Technology For Damper and Control Valve Applications Model Control Input Running Time Built-in Feedback List Price P VDC VDC No Charge P VDC VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P sec. PWM VDC No Charge P Floating Point VDC No Charge P-10019* On/Off VDC No Charge E x a m p l e : AF24-MFT US is the basic model. Add the P pre-set MFT configuration number and list price to the actuator when ordering, as needed. Note: Most popular configurations available at no additional cost. All other configurations carry a $30.00 list price. *Please Note: For On/Off control input, please order P and wire as on/off.

35 Feedback Charts for PICCVs with MFT Actuator PICCV (-PT) to PICCV (-PT) (.5 to 1 GPM) NEW NEW NEW NEW Note: Set point does not equal feedback on the TF24-MFT US, LF24-MFT US and AF24-MFT US. Set point does equal the feedback for the New Generation LRX24-MFT and ARX24-MFT. Please use NEW if the order was placed after July 24,

36 Feedback Charts for PICCVs with MFT Actuator PICCV (-PT) to PICCV (-PT) (1.5 to 3 GPM) Note: Set point does not equal feedback on the TF24-MFT US, LF24-MFT US and AF24-MFT US. Set point does equal the feedback for the New Generation LRX24-MFT and ARX24-MFT. 36

37 Feedback Charts for PICCVs with MFT Actuator PICCV (-PT) to PICCV (-PT) (4 to 5 GPM) Note: Set point does not equal feedback on the TF24-MFT US, LF24-MFT US and AF24-MFT US. Set point does equal the feedback for the New Generation LRX24-MFT and ARX24-MFT. 37

38 Feedback Charts for PICCVs with MFT Actuator PICCV (-PT) to PICCV (-PT) (6 to 8 GPM) Note: Set point does not equal feedback on the TF24-MFT US, LF24-MFT US and AF24-MFT US. Set point does equal the feedback for the New Generation LRX24-MFT and ARX24-MFT. 38

39 Feedback Charts for PICCVs with MFT Actuator PICCV (-PT) to PICCV (-PT) (9 to 10 GPM) Note: Set point does not equal feedback on the TF24-MFT US, LF24-MFT US and AF24-MFT US. Set point does equal the feedback for the New Generation LRX24-MFT and ARX24-MFT. 39

40 Feedback Charts for PICCVs with MFT Actuator PICCV (-PT) to PICCV (-PT) (12 to 14 GPM) Note: Set point does not equal feedback on the TF24-MFT US, LF24-MFT US and AF24-MFT US. Set point does equal the feedback for the New Generation LRX24-MFT and ARX24-MFT. 40

41 Feedback Charts for PICCVs with MFT Actuator PICCV (-PT) to PICCV (-PT) (16 to 18 GPM) Note: Set point does not equal feedback on the TF24-MFT US, LF24-MFT US and AF24-MFT US. Set point does equal the feedback for the New Generation LRX24-MFT and ARX24-MFT. 41

42 Feedback Charts for PICCVs with MFT Actuator PICCV PT to PICCV PT (18 to 22 GPM) Note: Set point does not equal feedback on the TF24-MFT US, LF24-MFT US and AF24-MFT US. Set point does equal the feedback for the New Generation LRX24-MFT and ARX24-MFT. 42

43 Feedback Charts for PICCVs with MFT Actuator PICCV PT to PICCV PT (24 to 26 GPM) Note: Set point does not equal feedback on the TF24-MFT US, LF24-MFT US and AF24-MFT US. Set point does equal the feedback for the New Generation LRX24-MFT and ARX24-MFT. 43

44 Feedback Charts for PICCVs with MFT Actuator PICCV PT to PICCV PT (26 to 28 GPM) Note: Set point does not equal feedback on the TF24-MFT US, LF24-MFT US and AF24-MFT US. Set point does equal the feedback for the New Generation LRX24-MFT and ARX24-MFT. 44

45 Feedback Charts for PICCVs with MFT Actuator PICCV PT to PICCV PT (30 to 33 GPM) Note: Set point does not equal feedback on the TF24-MFT US, LF24-MFT US and AF24-MFT US. Set point does equal the feedback for the New Generation LRX24-MFT and ARX24-MFT. 45

46 Feedback Charts for PICCVs with MFT Actuator PICCV PT to PICCV PT (33 to 40 GPM) Note: Set point does not equal feedback on the TF24-MFT US, LF24-MFT US and AF24-MFT US. Set point does equal the feedback for the New Generation LRX24-MFT and ARX24-MFT. 46

47 Feedback Charts for PICCVs with MFT Actuator PICCV PT to PICCV PT (44 to 52 GPM) Note: Set point does not equal feedback on the TF24-MFT US, LF24-MFT US and AF24-MFT US. Set point does equal the feedback for the New Generation LRX24-MFT and ARX24-MFT. 47

48 Feedback Charts for PICCVs with MFT Actuator PICCV PT to PICCV PT (56 to 65 GPM) Note: Set point does not equal feedback on the TF24-MFT US, LF24-MFT US and AF24-MFT US. Set point does equal the feedback for the New Generation LRX24-MFT and ARX24-MFT. 48

49 Feedback Charts for PICCVs with MFT Actuator PICCV PT to PICCV PT (70 to 80 GPM) Note: Set point does not equal feedback on the TF24-MFT US, LF24-MFT US and AF24-MFT US. Set point does equal the feedback for the New Generation LRX24-MFT and ARX24-MFT. 49

50 Feedback Charts for PICCVs with MFT Actuator PICCV PT to PICCV PT (90 to 100 GPM) Note: Set point does not equal feedback on the TF24-MFT US, LF24-MFT US and AF24-MFT US. Set point does equal the feedback for the New Generation LRX24-MFT and ARX24-MFT. 50

51 Field Adjustable Flow Ranges and P/T Port Pressure Flow Data Procedure: (1) Adjust valve to its full rated GPM opening. (2) Measure pressure across P/T ports. (3) For default flow rate, compare DeltaP to chart value. P/T ports to verify flow P/T Port Pressure Flow Data Model # Flow Rate DeltaP across Valve (GPM) P/T Ports PICCV (-PT) PICCV (-PT) PICCV (-PT) NEW PICCV (-PT) NEW PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) Field Adjustable Flow Ranges with the LRB24-3 and FlowSetR Default Model # Flow Rate Field Adjustable Valve (GPM)* Design Flow (GPM)** PICCV (-PT) 0.5 PICCV (-PT) 1 PICCV (-PT) 1.5 PICCV (-PT) to 1.3 PICCV (-PT) to 5.5 PICCV (-PT) 4 PICCV (-PT) 5 PICCV (-PT) 6 PICCV (-PT) 7 PICCV (-PT) 8 2 to 10 PICCV (-PT) 9 PICCV (-PT) 10 PICCV (-PT) 12 PICCV (-PT) 14 2 to 16 PICCV (-PT) 16 PICCV (-PT) 18 6 to 19 *The indicated default flows are maximum flow values at 100% actuator travel. However, the PICCV maintains a steady flow at any degree of ball opening and balances the system dynamically from 0 to 100% of the heating or cooling load. **Specified accuracy not guaranteed. PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT Please use NEW readings if order was placed after July 24,

52 Field Adjustable Flow Ranges and P/T Port Pressure Flow Data for Customized Flows Procedure: (1) Adjust valve to its full rated GPM opening. (2) Measure pressure across P/T ports. (3) For default flow rate, compare DeltaP to chart value. P/T ports to verify flow P/T Port Pressure Flow Data Model # Flow Rate DeltaP across Valve (GPM) P/T Ports PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) Field Adjustable Flow Ranges with the LRB24-3 and FlowSetR Default Model # Flow Rate Field Adjustable Valve (GPM)* Design Flow (GPM)** PICCV (-PT) 2.5 PICCV (-PT) 3.5 PICCV (-PT) to 5.5 PICCV (-PT) 5.5 PICCV (-PT) 6.5 PICCV (-PT) 7.5 PICCV (-PT) 8.5 PICCV (-PT) to 10 PICCV (-PT) 11 PICCV (-PT) 13 2 to 16 PICCV (-PT) 15 PICCV (-PT) 17 6 to 19 PICCV (-PT) 19 *The indicated default flows are maximum flow values at 100% actuator travel. However, the PICCV maintains a steady flow at any degree of ball opening and balances the system dynamically from 0 to 100% of the heating or cooling load. **Specified accuracy not guaranteed. PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT PICCV PT

53 Available Customized Flows and Certified Factory Calibrated Flows Customized Flows* PICCV s are available in a wide variety of the standard maximum flow rates as listed. This allows you to match the design flow rate much more accurately then it was possible with the selection of Cv-value of a conventional valve. If you want to customize the maximum flow rate of a PICCV you can do so, as noted in the increments in the table below. In an additional process we will set the PICCV to a specific flow rate to match your design flow, as noted in the table below. The smallest available increment is 0.50 GPM and the smallest flow is 0.50 GPM. Certified Factory Calibrated Flows (ZP-PICCV-CAL) Factory calibrated PICCV s will be programmed to a customized flow setting as mentioned in the opposite paragraph. Additionally, each single valve will be installed in a calibration rig to verify the flow rate with a high quality flow measurement device, calibrated to the requirements of ANSI/ISA , with traceability to NIST standards. For each PICCV calibrated you will receive a test certificate. Using this procedure allows for the highest flow accuracy in the field. Operating pressure ranges are 5-10 psi,10-30 psi, psi. Default pressure range is 5-30 psi. Expected flow accuracy ±5% (related to nominal va l ve flow ). This service is ava i l a ble for the 1/2 to 1-1/4 PICCV (-PT) to PICCV P T. Valve Size GPM Custom Flow Rates Actuator selections 1/2 2.5, 3.5, 4.5, 5.5 3/4 6.5, 7.5, 8.5, , 13, 15, 17, 19 Available Customized Flows* LRB24-3, LRCX24-3, LRX24-MFT, ARX24-MFT TF24-MFT US, LF24-MFT US, AF24-MFT US LRB24-3, LRCX24-3, LRX24-MFT, ARX24-MFT LF24-MFT US, AF24-MFT US LRB24-3, LRCX24-3, LRX24-MFT, ARX24-MFT LF24-MFT US, AF24-MFT US 1-1/4 19, 21, 23, 25 ARX24-MFT, AF24-MFT US 1-1/2 27, 29, 31, 32 ARX24-MFT, AF24-MFT US 2 34, 35, 37, 38, 39 ARX24-MFT, AF24-MFT US *Part numbers for the valve body custom flows are noted in the charts on page 52. Actuator selections are the same as the standard offerings. ORDERING EXAMPLE 1 2 Choose the desired valve/actuator combination based on valve ratings and actuator control parameters. PICCV PT + LRX24-MFT Specify Configuration (important) Multi-Function Technology: Set-up: Tagging: Calibration Charge: P (2-10 VDC input / 2-10 VDC feedback) NC (Normally Closed) AHU ZP-PICCV-CAL PICCV LRX24-MFT+P NC+AHU+ZP-PICCV-CAL 53

54 PICCV Running Times All MFT actuators have constant running time of 100 seconds. Whether they are set for on/off, floating or proportional control, the running time remains constant. Note for Floating Point Control with LRB24-3: These actuators have a constant running time. The running time is dependent on the model number or FlowSetR position as indicated in the table below. Some DDC controllers need an adjustment of the running time, otherwise they lose the position information. In any case, we recommend a position reset once a day. Running Time (sec.) Running Time (sec.) Model # Flow Rate LRX24-MFT, ARX24-MFT Valve (GPM) LRB24-3 TF24-MFT US, LF24-MFT US, AF24-MFT US PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV PT 18 na 100 PICCV PT 20 na 100 PICCV PT 22 na 100 PICCV PT 24 na 100 PICCV PT 26 na 100 PICCV PT 26 na 100 PICCV PT 28 na 100 PICCV PT 30 na 100 PICCV PT 33 na 100 PICCV PT 33 na 100 PICCV PT 36 na 100 PICCV PT 40 na 100 PICCV PT 44 na 100 PICCV PT 48 na 100 PICCV PT 52 na 100 PICCV PT 56 na 100 PICCV PT 60 na 100 PICCV PT 65 na 100 PICCV PT 70 na 100 PICCV PT 75 na 100 PICCV PT 80 na 100 PICCV PT 90 na 100 PICCV PT 100 na

55 PICCV Customized Flow Rate Running Times Running Time (sec.) Running Time (sec.) Model # Flow Rate LRX24-MFT, ARX24-MFT Valve (GPM) LRB24-3 TF24-MFT US, LF24-MFT US, AF24-MFT US PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV (-PT) PICCV PT 19 na 100 PICCV PT 21 na 100 PICCV PT 23 na 100 PICCV PT 25 na 100 PICCV PT 27 na 100 PICCV PT 29 na 100 PICCV PT 31 na 100 PICCV PT 32 na 100 PICCV PT 34 na 100 PICCV PT 35 na 100 PICCV PT 37 na 100 PICCV PT 38 na 100 PICCV PT 39 na

56 Instructions for Field Adjustment of Flow and Valve Sizing and Selection Instructions for Non-Spring Actuator Utilizing the FlowSetR Non-Spring Return Actuator: LRB24-3 Default set-up: FlowSetR The factory setting corresponds to the ordered flow rate (selected from Belimo s standard product range). The valves factory setting is in open position (valve always closes in CW direction). PICCV flow can be field adjusted by using a hex tool. T h e r e fo r e, the maximum flow can be increased or decreased within the va l ves adjustable flow ra n g e. Integrated Hex Tool To set or adjust desired maximum flow (actuator, FlowSetR and valve are connected): 1. Fully close the va l ve via actuator control signal or via manu a l ove r ride (press button and turn handle in clockwise direction). N o t e : The FlowSetR fixed clockwise end stop purposely p r events the actuator from returning to its full ze r o - d e gree position, eliminating excess rotation. 2. Use the integrated hex tool in the actuator lever to turn adjustment screw in plus (+) or minus (-) direction in order to move scale indicator to desired flow ra t e. A standard hex tool (i.e. Allen wrench) size 5/32 or 4mm can also be used to turn adjustment screw. FlowSetR Adjustable with hex tool size 5/32 [4mm] Sample scale PICCV On Floating Point actuators, the running time is constant but dependent on the overall angle of rotation. Avoid disconnecting FlowSetR from actuator or valve! If necessary, refer to instruction sheet on how to install FlowSetR to valve, and actuator to FlowSetR. Sizing and Selection of PICCVs To select the proper flow rate and actuation for your application: Sizing of the Pressure Independent Chara c t e ri zed Control Va l ves is based on GPM, and there is no need to calculate Cv ra t i n g. Pressure Independent Chara c t e ri zed Control Va l ves are 2 - way va l ves that operate between a 5-50 PSI operating ra n g e. For example: If an application requires 4 GPM: Select the valve rated for 4 GPM. In the catalog, this part number is the PICCV For example: If you wish to narrow the flow to 3.5 GPM: Narrowing the flow to 3.5 GPM can be achieved with the use of the FlowSetR if you have the LRB24-3 actuator. With the use of a 5/32" or 4 mm hex tool, the flow can be adjusted in the field. For all other MFT actuators, you may reprogram to 3.5 GPM using the PC software and following the MFT guidelines. Note: Please note that PICCV bodies have a range of flow. Consult page 51 and 52 for details. For example, the valve body PICCV can maintain flows from 0.50 GPM to 1.0 GPM, and the PICCV can maintain flows between 1.5 GPM to 5.5 GPM. There will be two Pressure/Te m p e rature ports as a standard o f fe ring for the 1-1/4" va l ves and larger, and ava i l a ble as an option for the 1" va l ves and smaller. The Pressure/Te m p e ra t u r e p o rts will be reflected in the part number as "PT". i.e PICCV PT + LF24-MFT US. The remaining step is to select the type of actuation, based on your requirements. Prior to ordering, please provide whether you wish to have the valve normally open or normally closed, and if spring return actuation is required, please note whether the valve is to spring open or spring closed upon power loss. For ex a m p l e : If your application for the above va l ve requires s p ring return, 2-10 VDC input signal, 100 sec run time and 2-10 VDC fe e d b a ck signal, select LF24-MFT US and MFT progra m- ming code P

57 PICCV Test and Balance Procedure, Troubleshooting PICCV Test and Balance Procedure 1. Verify that the system is purged and filled to the proper pressure. 2. Verify pump rotation. 3. Open all valves through the building management system if the total connected load➀ matches the pump GPM. Systems with diversity must have a percent of the valves closed to match the pump GPM. 4. Test total flow by accurate method.* 5. Decrease the pump speed until a flow decrease occurs. 6. Increase the pump speed until the original flow is reestablished. 7. Record system ΔP and provide this value to the ATC contractor. 8. Perform a Practical Test to verify that the designer s intent has been met. Taking a leaving air temperature can quickly verify the operation. *Accurate Methods Calibrated circuit setters on main lines Orifice Venturi Equipment pressure drops if the components are clean Ultrasonic Flowmeter Pump curves and triple duty valves have less accuracy than the above listed items PICCV Troubleshooting 1. Is the pump on and rotating properly? 2. Is the pressure differential adequate to produce design GPM? 3. Is the water temperature at the required level? 4. Is the PICCV installed in the right direction? 5. Is there too much diversity in the system? 6. Does the valve tag GPM match the listed design GPM? 7. Does the ATC signal stroke the valve in the right direction? 8. Are strainers plugged? 9. Is the coil installed counterflow? 10. Discharge temperature not to required rating: A. Is reset temperature high enough? B. Is air by-passing the coil? C. Are all coil areas heating/cooling uniformly? 11. Room cold complaints: A. Is there enough throw➁ to penetrate air to the occupancy level? ➁Throw is the distance discharge air is propelled in order to reach the occupant level. B. Test discharge air temperature and stratification. C. Is the building under a negative pressure? D. Is the hot water temperature at design? Resets may not be effective for reheat coils. GOOD IDEAS: Install taps on at least one valve with the largest DP requirement, or near the end run or near the DP transmitter. ➀Total connected load is the summation of all terminal GPM. Often, engineers will design a pumping system for the total GPM as listed for all of the coils. Some engineers will take advantage of diversity and realize that no more than ± 80% of the valves will be calling at any one time during normal operation. For instance, if you have 100 GPM of total connected load, a pump sized for 80 GPM could be installed. In this case, if all valves open after a weekend of being closed, none of the valves will handle the design flow rate. A requirement of 20% of the valves would have to be closed to match the pump to the total connected load. 57

58 Parallel Piping the PICCV to Achieve an Increase in Flow Rate Typical Parallel Piping in Relation to The Input and Output (Scale: None) The Pressure Independent Chara c t e ri zed Control Va l ves can be be piped in a parallel orientation to achieve increased flow ra t e s. Our PICCV va l ves are ava i l a ble in flows to 100 GPM. To a c h i eve flows larger than this, it is recommended to connect t wo of these va l ves in parallel leading to a common manifo l d. To correctly operate these va l ve s, the Belimo Multi Function Technology (MFT) will be employed to utilize one common control signal. For ex a m p l e, the first va l ve will be outfitted with an MFT actuator that will correspond to a 2-5 or 2.6 VDC signal. The second va l ve would be outfitted with an MFT actuator that would correspond to a 6-10 VDC signal. T h e r e fo r e, through a single 2-10 VDC output, the full flow range will be achieve d. The actuators will be wired in a parallel arra n g e m e n t. The established configured P Codes are P for 2-5 V D C, P for 2-6 V D C, and P for 6-10 V D C. This recommended application provides the control of flows up to 200 GPM by using two va l ve s.the top diagram details va l ves piped in a parallel arra n g e m e n t. The bottom diagra m features a typical single piping arra n g e m e n t. Typical Piping in Relation to The Input and Output (Scale: None) 58

59 Dimensions Pressure Independent Characterized Control Valve with Non-Spring Return Actuator Dimension with LRB24-3, LRX24-3 Dimensions with LRX24-MFT Dimensions (All ratings in brackets are in millimeters.) Valve A B C D E F 1/2" NPT 4.80 [122] 4.6 [117] 4.02 [102] 2.28 [58] 1.04 [24.4] 1.3 [33] 3/4" NPT 5.25 [133] 5.03 [128] 4.22[107] 2.38 [61] 1.04 [24.4] 1.3 [33] 1" NPT 7.05 [179] 6.85 [174] 4.80 [122] 3.23 [82] 1.60 [40.6] 1.60 [40.6] Dimensions with LRB24-3, LRX24-3 with P/T Ports Dimensions (All ratings in brackets are in millimeters.) Valve A B C D E F 1/2" NPT 4.80 [122] 4.6 [117] 4.02 [102] 2.28 [58] 1.04 [24.4] 1.3 [33] 3/4" NPT 5.25 [133] 5.03 [128] 4.22 [107] 2.38 [61] 1.04 [24.4] 1.3 [33] 1" NPT 7.05 [179] 6.85 [174] 4.80 [122] 3.23 [82] 1.60 [40.6] 1.60 [40.6] Dimensions with LRX24-MFT with P/T Ports Dimensions (All ratings in brackets are in millimeters.) Valve A B C D E F 1/2" NPT 5.3 [135] 4.6 [117] 5.4 [137] 3.69 [94] 1.04 [24.4] 2.60 [66] 3/4" NPT 5.8 [147] 5.03 [128] 5.7 [145] 3.69 [94] 1.04 [24.4] 2.60 [66] 1" NPT 7.05 [179] 6.85 [174] 6.05 [154] 4.0 [102] 1.60 [40.6] 2.90 [73.65] Dimensions (All ratings in brackets are in millimeters.) Valve A B C D E F 1/2" NPT 5.3 [135] 4.6 [117] 5.4 [137] 3.69 [94] 1.04 [24.4] 2.60 [66] 3/4" NPT 5.8 [147] 5.03 [128] 5.7 [145] 3.69 [94] 1.04 [24.4] 2.60 [66] 1" NPT 7.05 [179] 6.85 [174] 6.05 [154] 4.0 [102] 1.60 [40.6] 2.90 [73.65] Dimensions with ARX24-MFT with P/T ports Dimensions with ARX24-MFT with P/T ports Dimensions (All ratings in brackets are in millimeters.) Valve A B C D E F 1-1/4" NPT 8.75 [222] 8.75 [222] 6.62 [168] 4.33 [110] 1.77 [45] 3.03 [77] 1-1/2" NPT 8.00 [203] 8.00 [203] 6.62 [168] 4.33 [110] 1.77 [45] 3.03 [77] 2" NPT* 8.5 [216] 8.5 [216] 6.62 [168] 4.4 [112] 1.77 [45] 3.03 [77] *Flows to 40 GPM. Dimensions (All ratings in brackets are in millimeters.) Valve* A B C D E F G H 2" NPT [416.2] 15.6 [396.2] 9.38 [238.3] 6.31 [160.3] 2.65 [67.3] 3.05 [77.5] [ ] 20.6 [523.24] 2" NPT with larger flows from 44 GPM to 100 GPM 59

60 Dimensions Pressure Independent Characterized Control Valve with Spring Return Actuator TF24-MFT US TF24-MFT US with P/T ports Dimensions (All ratings in brackets are in millimeters.) Valve A B C D E F 1/2" NPT 4.80 [122] 4.6 [117] 4.02 [102] 2.28 [58] 1.04 [24.4] 1.3 [33] Dimensions (All ratings in brackets are in millimeters.) Valve A B C D E F 1/2" NPT 5.3 [135] 4.6 [117] 5.4 [137] 3.69 [94] 1.04 [24.4] 2.60 [66] LF24-MFT US AF24-MFT US with P/T ports Dimensions (All ratings in brackets are in millimeters.) Valve A B C D E F 1/2" NPT 4.80 [122] 4.6 [117] 4.02 [102] 2.28 [58] 1.04 [24.4] 1.3 [33] 3/4" NPT 5.25 [133] 5.03 [128] 4.22 [107] 2.38 [61] 1.04 [24.4] 1.3 [33] 1" NPT 7.05 [179] 6.85 [174] 4.80 [122] 3.23 [82] 1.60 [40.6] 1.60 [40.6] LF24-MFT US with P/T ports Dimensions (All ratings in brackets are in millimeters.) Valve A B C D E F 1-1/4" NPT 8.75 [222] 8.75 [222] 6.62 [168] 4.33 [110] 1.77 [45] 3.03 [77] 1-1/2" NPT 8.0 [203] 8.0 [203] 6.62 [168] 4.33 [110] 1.77 [45] 3.03 [77] 2" NPT 8.5 [216] 8.5 [216] 6.62 [168] 4.4 [112] 1.77 [45] 3.03 [77] *Flows to 40 GPM. AF24-MFT US with P/T ports Dimensions (All ratings in brackets are in millimeters.) Valve A B C D E F 1/2" NPT 5.3 [135] 4.6 [117] 5.4 [137] 3.69 [94] 1.04 [24.4] 2.60 [66] 3/4" NPT 5.8 [147] 5.03 [128] 5.7 [145] 3.69 [94] 1.04 [24.4] 2.60 [66] 1" NPT 7.05 [179] 6.85 [174] 6.05 [154] 4.0 [102] 1.60 [40.6] 2.90 [73.65] Dimensions (All ratings in brackets are in millimeters.) Valve* A B C D E F G H 2" NPT [416.2] 15.6 [396.2] 9.38 [238.3] 6.31 [160.3] 2.65 [67.3] 3.05 [77.5] [ ] 21.9 [556.3] 2" NPT with larger flows from 44 GPM to 100 GPM 60

61 Wiring Diagrams for LRB24-3 Actuator 61

62 Wiring Diagrams for LRX24-MFT and ARX24-MFT Actuators 62

63 Wiring Diagrams for TF24-MFT US Actuators Wiring Diagrams 4 to 20 ma Control Signal Notes Provide overload protection and disconnect as required. Actuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. Actuator may also be powered by 24 VDC. ZG-R01 may be used. 2 to 10 VDC Control Signal 63

64 Wiring Diagrams for LF24-MFT US and AF24-MFT US Actuators 4 to 20 ma Control Signal Auxiliary Switch AF24-MFT-S US Notes Provide overload protection and disconnect as required. 1 Actuators may be connected in parallel if not mechanically mounted 2 to the same shaft. Power consumption and input impedance must be observed. 3 Actuator may also be powered by 24 VDC. Auxiliary Switch LF24-MFT-S US 2 to 10 VDC Control Signal ZG-R01 may be used. For end position indication, interlock control, fan startup, etc., AF24-MFT-S US incorporates two built-in auxiliary switches: 2 x SPDT, 7A VAC, UL listed, one switch is fixed at +5, one is adjustable 25 to 85. LF24-MFT-S US incorporates one built-in auxiliary switch: 1 x SPDT, 6A VAC, UL listed, adjustable 0 to 95. Meets UL and CSA requirements without the need of an electrical ground connection.

65 Pressure Independent Characterized Control Valve Heat Pump Applications Optimize Your Heat Pump Application by Using a Pressure Independent Characterized Control Valve What are the benefits? A balanced system is achieved without the need for a balancer to manually balance each circuit. Because the system is dynamic and the PICCV performs dynamic balancing, Differential Pressures are no longer an issue to be concerned with. The PICCV will maintain a constant flow at part load and during morning warm-up when all loops become critical. With the PICCV, each terminal gets the required flow, no over-flow or under-flow at this critical time. The PICCV allows a mechanic to easily commission additional circuits after the initial system is up and running, again thanks to dynamic balancing capability. The PICCV is available in flow rates from.5 GPM to 19 GPM. Choosing the right PICCV is as easy as determining the appropriate flow for your heat pump and then choosing the valve that satisfies the flow requirement. How does it work? Keep with the same idea of a conventional heat pump system, then add the Belimo PICCV (2-way Pressure Independent Characterized Control Valve). Think savings, and not necessarily first cost of equipment. Add a VFD (with its known and accepted benefits) and a Belimo PICCV as your flow control valve, and you have now optimized your system flow for very little additional cost. Heat Pump in Heating Mode Heat Pump in Cooling Mode 65

66 P2 Series PICCV for Water Source Heat Pumps for Fast Running Time with Switch Options and On/Off, Non-Spring Return Actuator Two-way Valve with Chrome Plated Brass Ball and Brass Stem Service: Flow Characteristic: Media Temp Range: Ambient Temp Range: Differential Pressure Across Valve Range ( P): chilled or hot water, 60% glycol equal percentage 0 F to 212 F [-18 C to 100 C] -22 F to 122 F [-30 C to 50 C] 5 to 50 psid Actuator: Running Time: Power Supply 40 sec 24 VAC/VDC LRCB P2 Pressure Independent Characterized Control Valve, Chrome Plated Brass Ball and Brass Stem Va l v e N o n -Spring Return Actuator M o d e l Va l v e On/Off # F l ow Rate Nominal Size C l o s e - P I C C V L i t e r / D N O f f Va l v e G P M s e c I n ch e s m m p s i LRCB24-3 PICCV * / Pg 66 PICCV * / Pg 66 PICCV * / Pg 66 PICCV * / Pg 66 PICCV * / Pg 66 PICCV * / Pg 66 PICCV * / Pg 66 PICCV / Pg 66 PICCV / Pg 66 PICCV / Pg 66 PICCV / Pg 66 PICCV / Pg 66 PICCV ** Pg 66** PICCV ** Pg 66 PICCV ** Pg 66 PICCV ** Pg 66 Electrical 3 ft cable Connection 1/2 conduit fitting N o t e : Other actuator options including switch options are ava i l a bl e. Please contact your Belimo Account Manager or call for assistance. Options (add to list price) LRCB24-3-S Built-in aux. switch (-S) Pg 68 * 1 / 2 body has two different disc sizes (.50 GPM to 1 GPM) (1.5 GPM to 5.5 GPM) * * 1 body has two different disc sizes (12 GPM to 16 GPM) (17 GPM to 19 GPM) 66

67 P2 Series PICCV for Water Source Heat Pumps for Fast Running Time with Switch Option and On/Off, Non-Spring Return Actuator Two-way Valve with Chrome Plated Brass Ball and Brass Stem with P/T Ports, NPT Female Ends Service: Flow Characteristic: Media Temp Range: Ambient Temp Range: Differential Pressure Across Valve Range ( P): chilled or hot water, 60% glycol equal percentage 0 F to 212 F [-18 C to 100 C] -22 F to 122 F [-30 C to 50 C] 5 to 50 psid Actuator: Running Time: Power Supply 40 sec 24 VAC/VDC L R C B P2 Pressure Independent Characterized Control Valve, Chrome Plated Brass Ball and Brass Stem, P/T Ports Va l v e N o n -Spring Return Actuator M o d e l Va l v e O n / O f f # F l ow Rate Nominal Size C l o s e - P I C C V L i t e r / D N O f f Va l v e G P M s e c I n ch e s m m p s i LRCB24-3 PICCV PT* / Pg 66 PICCV PT* / Pg 66 PICCV PT* / Pg 66 PICCV PT* / Pg 66 PICCV PT* / Pg 66 PICCV PT* / Pg 66 PICCV PT* / Pg 66 PICCV PT / Pg 66 PICCV PT / Pg 66 PICCV PT / Pg 66 PICCV PT / Pg 66 PICCV PT / Pg 66 PICCV PT** Pg 66 PICCV PT** Pg 66 PICCV PT** Pg 66 PICCV PT** Pg 66 Electrical 3 ft cable Connection 1/2 conduit fitting Options (add to list price) LRCB24-3-S Built-in aux. switch (-S) Pg 68 *1/2 body has two different disc sizes (.50 GPM to 1 GPM) (1.5 GPM to 5.5 GPM) **1 body has two different disc sizes (12 GPM to 16 GPM) (17 GPM to 19 GPM) 67

68 Pressure Independent Characterized Control Valve with On/Off, Non-Spring Return Actuator, P/T Ports (Optional) A p p l i c a t i o n : The Pressure Independent Chara c t e ri zed Control Va l ve along with the LRCB24-3 is paired together specifically for use in Heat Pump applications to precisely control the flow of condenser water. This assembly is suitable for use in a hydronic system with constant or variable flow. Valve Specifications S e rv i c e chilled or hot wa t e r, 60% glycol F l ow chara c t e ri s t i c equal percentage S i ze 1/2, 3/4, 1 Type of end fitting fe m a l e, NPT M a t e ri a l s : B o d y forged bra s s, nickel plated B a l l chrome plated bra s s S t e m chrome plated bra s s Seat O-ri n g s V i t o n S e a t fiberglass reinforced teflon PTFE C h a ra c t e rizing disc T E F Z E L Pa ck i n g 2 EPDM O-ri n g s, lubri c a t e d D i a p h ra g m p o l yester reinforced silicone Regulator components stainless steel/bra s s / D e l rin 500 AF S p ri n g stainless Steel Pe t e s Plug* (Qty 2) 1 / 4 b ra s s / N o rtel (Optional P/T) Body pressure ra t i n g 600 PSI Media temp. ra n g e 0 F to 212 F [-18 C to 100 C] Close off pressure 200 PSI L e a k a g e ANSI Class IV (0.01% of rated va l ve capacity at 50 psi diffe r e n t i a l ) F l ow rate 1/2 0.5 GPM [.03 l/s], 1 GPM [.06 l/s], 1.50 GPM [0.09 l/s], 2 GPM [.13 l/s], 3 GPM [.19 l/s], 4 GPM [.25 l/s], 5 GPM [.32 l/s] F l ow rate 3/4 6 GPM [0.37 l/s], 7 GPM [0.44 l/s], 8 GPM [0.50 l/s], 9 GPM [0.57 l/s], 10 GPM [0.63 l/s] F l ow rate 1 12 GPM [0.76 l/s], 14 GPM [0.88 l/s], 16 GPM [1.01 l/s], 18 GPM [1.14 l/s] R a n g e a b i l i t y 100 : 1 D i f ferential pressure 5 to 50 PSI o p e rating ra n g e F l ow accuracy (absolute) ± 5% (5 to 50 PSI) Va riation due to ± 5% (5 to 50 PSI) m a nu fa c t u ring tolera n c e s Hysteresis (absolute) 1% Weight of va l ve body 1 / 2 = 2.52 lbs, 3/4 = 3.05 lbs 1 = 4.98 lbs Te f zel and Teflon are registered tra d e m a rks of Dupont * Pe t e s Plugs offered as an option on 1/2, 3/4 and 1 va l ve s. Actuator Specifications LRCB24-3 On/Off Power Supply 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% Power Consumption 1.5 W (0.2 W) Transformer Sizing 3 VA (Class 2 power source) Electrical Connection 18 GA plenum rated cable 1/2 conduit connector 3 ft [1m] 10 ft [3m] 16 ft [5m] Overload Protection electronic throughout 0 to 95 rotation Control On/Off Input Impedance 600 Angle of Rotation 95 Direction of Rotation reversible with protected switch Position Indication handle Manual Override external push button and handle Running Time Humidity 40 second constant independent of load 5 to 95% RH non condensing (EN ) Ambient Temperature -22 F to +122 F [-30 C to +50 C] Storage Temperature -40 F to +176 F [-40 C to +80 C] Housing NEMA 2/IP54 Housing Material Agency Listings Noise Level UL94-5VA culus acc. to UL A/-2-14, CAN/CSA E , CSA C22.2 No , CE acc. to 89/336/EEC and (-S Models) 2006/95/EC <35dB(A) Quality Standard ISO 9001 LRCB24-3-S Auxiliary Switch 1 SPDT, 3A (0.5A 250 V Weight of Actuator 1.08 lbs [0.49 Kg] Rated Impulse Voltage 800V, Type of action 1 (1.B for -S version), Control Pollution Degree 3. 68

69 Pressure Independent Characterized Control Valve with On/Off, Non-Spring Return Actuator Dimensions LRCB24-3 LRCB24-3 with P/T Ports Dimensions (All ratings in brackets are in millimeters.) Valve A B C D E F 1/2" NPT 4.80 [122] 4.6 [117] 4.02 [102] 2.28 [58] 1.04 [24.4] 1.3 [33] 3/4" NPT 5.25 [133] 5.03 [128] 4.22[107] 2.38 [61] 1.04 [24.4] 1.3 [33] 1" NPT 7.05 [179] 6.85 [174] 4.80 [122] 3.23 [82] 1.60 [40.6] 1.60 [40.6] Dimensions (All ratings in brackets are in millimeters.) Valve A B C D E F 1/2" NPT 5.3 [135] 4.6 [117] 5.4 [137] 3.69 [94] 1.04 [24.4] 2.60 [66] 3/4" NPT 5.8 [147] 5.03 [128] 5.7 [145] 3.69 [94] 1.04 [24.4] 2.60 [66] 1" NPT 7.05 [179] 6.85 [174] 6.05 [154] 4.0 [102] 1.60 [40.6] 2.90 [73.65] Wiring Diagram LRCB24-3 On/Off 69

70 ZS-CCV New Control Valve Weather Shield Installation Instructions APPLICATION The ZS-CCV weather shield provides moderate protection for valves which are mounted outdoors. This product is designed as a water tight enclosure. The housing allows easy mounting over the actuator, while allowing easy viewing of the actuator in operation. Weather shield for PICCV/CCV to provide protection fo r a c t u a t o rs in outdoor applications. S p e c i f i c a t i o n s C ove r Pe rimeter Gaske t R u bber Gaske t S p ring Clips Te m p e rature limitations: Plate (ZS-CCV- 100 ) P l a t e PETG with UV resistant smoke tint Silicon Rubb e r Silicon Rubb e r Stainless Steel -22 F to 122 F (-30 C to 50 C) A l u m i nu m G a l vaneal w/bl a ck powder coat Part Number L W H ZS - CCV [254] 7.75 [197] 4 [100] ZS - CCV [413] 8.75 [222] 4.5 [114] ZS - CCV [398] 7.61 [193] 4.0 [102] WEATHER SHIELDS* ZS-CCV-60 Pressure Independent Characterized Control Valves (PICCV) ZS-CCV-90 Pressure Independent Characterized Control Valves (PICCV) ZS-CCV-100 Pressure Independent Characterized Control Valves (PICCV) LR (B) (X) (CX) AR (X) (CX) LF AF List Price with CCV EXT-KIT *Designed for NEMA 4 specifications PARTS LIST Cover including Rubber Perimeter Gasket, Rubber Gasket Back Plate Anti-Rotation Post with screw and lock washer Valve Gasket Assorted Cap plugs for unused holes Screws: LF - 2 screws provided AF - 2 bolts with nylon insert locking nuts LR(B)(X)(CX), AR(X)(CX) - 1 screw, 1 washer 70

71 Flexible Products Introduction Table of Contents Flexible Section Introduction...73 Ordering...74 Non-Spring Return At A Glance...75 MFT Programming Codes...76 Non-Spring Return Base Actuator Table...76 Multi-Functional Technology Belimo damper actuators and control valves with Multi-Function Technology (MFT) include standard 2 to 10 VDC proportional control functions, plus they can be re-programmed. Parameters can be changed on-site to optimize/enable application. Parameters can be set for voltage control (VDC), time proportional control (PWM), floating point, on-off or feedback signal. You can also set, modify or read position, running time, mechanical working range, address, status, and diagnostics. MFT allows you to adapt the actuator to your system for service replacement and to improve system functionality. 71

B2 Series Characterized Control Valve, Spring Return Actuator

B2 Series Characterized Control Valve, Spring Return Actuator Series Characterized Control Valve, Spring ctuator Two-way Valve with Stainless Steel all and Stem, NPT Female Ends Service: Flow Characteristic: Media Temp Range: Maximum Differential: Pressure ( P) mbient

More information

Technical Documentation Electronic Characterized Control Valves (CCV)

Technical Documentation Electronic Characterized Control Valves (CCV) Technical Documentation Electronic Characterized Control Valves (CCV) Effective March 005 Table of Contents Control Valve Product Range... Valve/ctuator Selection t Glance...4 Electronic Characterized

More information

B350L, 3-Way, Diverting Ball Valve Chrome Plated Brass Ball and Nickel Plated Brass Stem

B350L, 3-Way, Diverting Ball Valve Chrome Plated Brass Ball and Nickel Plated Brass Stem B350L, 3-Way, Diverting Ball Valve hrome Plated Brass Ball and Nickel Plated Brass Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating

More information

P2050B050, 1/2, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends

P2050B050, 1/2, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends pplication The Pressure Independent haracterized ontrol Valve is typically used in air handling units on heating and cooling coils, and fan coil unit heating or cooling coils. Some other common applications

More information

B212, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem

B212, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem , -Way, haracterized ontrol Valve Stainless Steel all and Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils. Some

More information

F780HD, 3, 3-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F780HD, 3, 3-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc F80HD, 3, 3-Way utterfly Valve Resilient Seat, 304 Stainless Steel Disc pplication Valve is designed for use in NSI flanged piping systems to meet the needs of bi-directional high flow HV hydronic applications

More information

P2075B100-P, 3/4, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends

P2075B100-P, 3/4, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends P2075100-P, 3/4, Pressure Independent Valve hrome Plated rass all and rass Stem, NPT emale nds pplication The Pressure Independent haracterized ontrol Valve is typically used in air handling units on heating

More information

P2050B005, 1/2, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends

P2050B005, 1/2, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends P2050005, 1/2, Pressure Independent Valve hrome Plated rass all and rass Stem, NPT emale nds pplication The Pressure Independent haracterized ontrol Valve is typically used in air handling units on heating

More information

F6 Series 2-Way, Victaulic Butterfly Valve

F6 Series 2-Way, Victaulic Butterfly Valve F6 Series 2-Way, Victaulic Butterfly Valve 200 psi (2 to 12 ) bubble tight shut-off Long stem design allows for 2 insulation Completely assembled and tested, ready for installation Application These valves

More information

B2150VB-055, 1-1/2, V Ball Control Valve Hardened Chrome Plated Carbon Steel Body, Stainless Steel Ball and Stem

B2150VB-055, 1-1/2, V Ball Control Valve Hardened Chrome Plated Carbon Steel Body, Stainless Steel Ball and Stem 50V-055, -/, V all ontrol Valve Hardened hrome Plated arbon Steel ody, Stainless Steel all and Stem Product eatures ast quarter turn open or closed operation, Stainless steel ball and stem, Positive shut-off,

More information

F650HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F650HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc 650H, -Way utterfly Valve Resilient Seat, 304 Stainless Steel isc Product eatures 00 psi ( to ) and 50 psi (4 to 4 ) 0% leakage, Long stem design allows for insulation, Valve face-to-face dimensions comply

More information

B6400VB-350, 4, V Ball Control Valve Carbon Steel Body, Hardened Chrome Plated, Stainless Steel Ball and Stem

B6400VB-350, 4, V Ball Control Valve Carbon Steel Body, Hardened Chrome Plated, Stainless Steel Ball and Stem 6400V-350, 4, V all ontrol Valve arbon Steel ody, Hardened hrome Plated, Stainless Steel all and Stem Product eatures ast quarter turn open or closed operation, Stainless steel ball and stem, Positive

More information

7000 Series Bronze Globe Valves Two-Way Normally Open

7000 Series Bronze Globe Valves Two-Way Normally Open 7000 Series Bronze Globe Valves Two-Way Normally Open / to in. Screwed NPT Two-Way Normally Open Spring Return Stem Up Open Globe Valves Two-Way Normally Open Assemblies Size in. / /4 Cv (K vs ) 0.4 (0.4).

More information

B6400S-186, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem

B6400S-186, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem 6400S-86, 2-Way, haracterized ontrol Valve Stainless Steel all and Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils.

More information

Spring Return DuraDrive Proportional Actuator

Spring Return DuraDrive Proportional Actuator MS40-7043, MS4-7073, MS4-753 Spring Return DuraDrive Proportional Actuator For spring return applications that require proportional modulation control of dampers and valves in HVAC systems. Features: Proportional

More information

B250, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem

B250, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem 250, 2-ay, haracterized ontrol Valve Stainless Steel all and Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils.

More information

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A) echnical Data sheets GRK4A-SR-5 Modulating SuperCap rotary actuator with emergency setting function and extended functionalities for butterfly valves and ball valves with mounting flange ISO 511-F05 orque

More information

Non-Spring Return DuraDrive Modulating Actuator

Non-Spring Return DuraDrive Modulating Actuator MS41-60xx Series n-spring Return DuraDrive Modulating Actuator The DuraDrive direct coupled 24 Vac non-spring return rotary electric actuators are designed for modulating control of dampers. S41-60xx ries

More information

F6125HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6125HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc 6125H, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc Product eatures 200 psi (2 to 12 ) and 150 psi (14 to 24 ) 0% leakage, Long stem design allows for 2 insulation, Valve face-to-face dimensions

More information

GM24-MFT US. Proportional damper actuator, non-spring return, Multi-Function Technology

GM24-MFT US. Proportional damper actuator, non-spring return, Multi-Function Technology GM-MFT US Proportional damper actuator, non-spring return, Multi-Function Technology GM-MFT US Torque min. 0 in-lb Control to 0 VDC (DEFULT) Feedback to 0 VDC (DEFULT) pplication For proportional modulation

More information

F6100HD, 4, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6100HD, 4, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc 6100H, 4, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc pplication Valve is designed for use in NSI flanged piping systems to meet the needs of bi-directional high flow HV hydronic applications

More information

B240, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem

B240, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem 0, 2-ay, haracterized ontrol Valve Stainless Steel all and Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils. Some

More information

F680HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F680HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc 680H, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc Product eatures 200 psi (2 to 12 ) and 150 psi (14 to 24 ) 0% leakage, Long stem design allows for 2 insulation, Valve face-to-face dimensions

More information

Functional data Factory settings Variable Settings

Functional data Factory settings Variable Settings echnical data sheet Rotary actuator RF-MF(-O) Multifunctional rotary actuator with emergency control for and 3 way control ball valve orque Nm Nominal voltage AC/DC V Control: Modulating DC... V or variable

More information

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable echnical data sheet S--MF- Multifunctional rotary actuator for butterfly valves orque 00 Nm Nominal volta e V Control: ontrol configurable confi urable Position feedback: configurable Auxiliary u iliary

More information

B2...VS Series, 2-way, Ball Valve Bronze Body, Stainless Steel Ball and Stem

B2...VS Series, 2-way, Ball Valve Bronze Body, Stainless Steel Ball and Stem 2...VS Series, 2-way, all Valve ronze ody, Stainless Steel all and Stem Live-load packing set Stainless steel ball & stem low-out proof stem design Technical Data Media chilled or hot water, glycol, #

More information

Non-Spring Return EconoDrive Proportional Actuator

Non-Spring Return EconoDrive Proportional Actuator MSD-0x3 Series Non-Spring Return EconoDrive Actuator EconoDrive overshaft actuators are designed to provide an economical and reliable solution for many overshaft damper and ball valve requirements. All

More information

SENSORS. Seamlessly Integrated SENSORS

SENSORS. Seamlessly Integrated SENSORS 20 Seamlessly Integrated Innovative technology to work seamlessly with all leading control companies ensuring performance. Reliable and accurate readings providing energy and cost-effi cient control backed

More information

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

Technical data. Safety notes.  T3-LR24A-SR en v Subject to changes 1 / 2 echnical data sheet LR4A-SR Modulating rotary actuator for and -way control ball valves orque Nm Nominal voltage AC/DC 4 V Control: Modulating DC... V Position feedback: DC... V echnical data Safety notes

More information

3-Way Ball Valves. Overview. Applications. Features & Benefits. Datasheet

3-Way Ball Valves. Overview. Applications. Features & Benefits. Datasheet 3-Way Ball s Datasheet Overview 3-way Ball s are coupled with DA-Series Actuators to provide three-way mixing or diverting flow control. The ball valves are 1/4-turn rotary control valves and are available

More information

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool echnical data sheet LMA-MF-P Multifunctional damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx.

More information

Ball Valve Features and Benefi ts B2...VS / VSS and B3...L

Ball Valve Features and Benefi ts B2...VS / VSS and B3...L all Valve Features and enefi ts 2...VS / VSS and 3...L Tech.Doc - 07/17 - Subject to change. elimo ircontrols (US), Inc. 2-way and 3-way confi guration ronze with stainless steel trim (2-way) Nickel plated

More information

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool echnical data sheet SMA--P Multifunctional damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. m orque

More information

LM Series Direct Coupled Actuator

LM Series Direct Coupled Actuator LM Series Direct Coupled Actuator Small Yet Powerful Minimum in-lb torque in a compact package. For damper areas up to 8 sq-ft*. Quiet Plus VAV terminal unit by Warren Technology Areas of Application VAV

More information

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

Technical data.  T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC echnical data sheet SMASR Modulating damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. 4 m orque Nm

More information

Overview of types. Technical data

Overview of types. Technical data echnical data sheet SHA-.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control dampers

More information

F6100HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6100HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc 6100H, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc Product eatures 200 psi (2 to 12 ) and 150 psi (14 to 24 ) 0% leakage, Long stem design allows for 2 insulation, Valve face-to-face dimensions

More information

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC echnical data sheet SMA-PC Parameterisable damper actuator for adjusting air dampers in ventilation and air-conditioning systems in buildings Air damper size up to approx. m orque 0 Nm Nominal voltage

More information

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing echnical data sheet Rotary actuator LR4A Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage AC/DC 4 V Control: Open/close or -point echnical data Electrical data Nominal voltage

More information

Technical data. Parameterisable damper actuator in the

Technical data. Parameterisable damper actuator in the echnical data sheet Parameterisable damper actuator in the IP66 protective housing for or adjusting ad usting air dampers in industrial plants and in technical building installations For air dampers up

More information

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque echnical data sheet GK4A- Communicative SuperCap rotary actuator with emergency setting function and extended functionalities for adjusting air dampers in ventilation and air-conditioning systems for building

More information

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O echnical data sheet NRF24A-SR-S2(-O) Modulating rotary actuator with emergency function for 2- and 3-way ball valves orque or ue 10 Nm Nominal voltage AC/DC 24 V Control: modulating DC 0... 10 V Position

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet GM4A-SR-P Modulating damper actuator for operating air control dampers in ventilation and airconditioning systems for building services installations For air dampers up to approx. 8

More information

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2 echnical data sheet Rotary actuator LRA Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage AC... 4 V Control: Open/close or -point echnical data Electrical data Nominal voltage

More information

Technical data sheet. Technical data. Safety notes

Technical data sheet. Technical data. Safety notes echnical data sheet LM4A-F Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. m orque 5 Nm Nominal

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet GR24A--R Communicative Retrofit rotary actuator for rotary valves and butterfly valves Nominal torque 40 Nm Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Position

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet SM4A-SR-P Modulating damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. 4 m orque

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet MC4A-SR-F Modulating damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx..4 m orque

More information

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return echnical data sheet SF24A- Communicative spring return actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx.

More information

Explosion proof rotary actuator - On/Off or programmable regulating actuator

Explosion proof rotary actuator - On/Off or programmable regulating actuator Explosion proof rotary actuator - On/Off or programmable regulating actuator Direct mounting for quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Type 3004 can

More information

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8 to 1/2 NPT. Proportional Valves. Features. 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/8" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Control achieved by applying straight voltage between 0 and 24 VDC

More information

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4 to 1/2 NPT. Proportional Valves. Features. 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

2/2 way Proportional Valve (motordriven)

2/2 way Proportional Valve (motordriven) 2/2 way Proportional (motordriven) Actuator isolated from fl ow path Excellent range and fast response times Low power consumption Orifi ce sizes 8 to 25 mm Versions: Standard, positioner, process controller

More information

FEATURES OPTIONAL FEATURES

FEATURES OPTIONAL FEATURES -00--0 B Series The Assured Automation B Series electric valve actuators offer a rugged design for quarter turn industrial applications. Designed for use on quarter turn (0 ) ball valves, butterfly valves,

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

B6300VB-207, 3, V Ball Control Valve Carbon Steel Body, Hardened Chrome Plated, Stainless Steel Ball and Stem

B6300VB-207, 3, V Ball Control Valve Carbon Steel Body, Hardened Chrome Plated, Stainless Steel Ball and Stem 6300V-207, 3, V all ontrol Valve arbon Steel ody, Hardened hrome Plated, Stainless Steel all and Stem Product eatures ast quarter turn open or closed operation, Stainless steel ball and stem, Positive

More information

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Electrical data Nominal voltage AC 230 V Nominal voltage frequency echnical data sheet SY3-30-MP- Communicative rotary actuator for butterfly valves ominal torque 50 m ominal voltage Control modulating, communicative DC (0)...0 V Variable Position feedback DC...0 V Variable

More information

Technical data. Safety notes

Technical data. Safety notes echnical data sheet M3A-F Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. m orque 5 m ominal

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet Communicative damper actuator for adjusting dampers in technical building installations Air damper size up to approx. m² Nominal torque 5 Nm Nominal voltage AC/DC 24 V Control Modulating

More information

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator ANSI version Application Control valves designed for mechanical and plant engineering. Suitable for liquids, gases and steam

More information

.1 Materials and installation for steel piping, valves and fittings for hydronic systems in building services piping..2 Related Sections.

.1 Materials and installation for steel piping, valves and fittings for hydronic systems in building services piping..2 Related Sections. Issued 2006/08/01 Section 15183 Hydronic Systems: Steel Page 1 of 6 PART 1 GENERAL 1.1 SUMMARY.1 Section Includes..1 Materials and installation for steel piping, valves and fittings for hydronic systems

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet SVK24A--PC Communicative globe valve actuator with emergency control function for 2-way and 3-way globe valves Actuating force 1500 N Nominal voltage AC/DC 24 V Control modulating,

More information

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation Vmax low-n: Vmax for low-noise operation

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation Vmax low-n: Vmax for low-noise operation echnical data sheet EP..R-R6+BAC Characterised control valve with sensor-operated flow control, 6-way, Internal thread, PN 16 (EPIV) Nominal voltage AC/DC 24 V Control modulating, communicative wo sequences

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet GM24A--P Communicative damper actuator for adjusting dampers in technical building installations Air damper size up to approx. 8 m² Nominal torque 4 Nm Nominal voltage AC/DC 24 V Control

More information

Power consumption Operation At rest Wire sizing

Power consumption Operation At rest Wire sizing echnical data sheet NM24P-SR Modulating Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx..6 m 2 orque 8

More information

Technical data. Safety notes. Power consumption In operation At rest For wire sizing

Technical data. Safety notes. Power consumption In operation At rest For wire sizing echnical data sheet Damper actuator NM4A-SR-P Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air control dampers up

More information

Rotary gear motor series AG8...

Rotary gear motor series AG8... Rotary gear motor series AG8... The electric actuator belonging to AG8 series is designed to operate gas valves and air dampers in ventilation and air conditioning systems. The compact design and universal

More information

Provides line voltage capable single Pole Double-Throw (SPDT) switch and 140Ω, 1KΩ, 2KΩ or 10KΩ feedback potentiometric.

Provides line voltage capable single Pole Double-Throw (SPDT) switch and 140Ω, 1KΩ, 2KΩ or 10KΩ feedback potentiometric. VA9310 Non Spring Return Actuators Product Bulletin The VA9310 Series Electric Non Spring Return Actuators are used to provide accurate positioning on Johnson Controls VG1000 Series DN15 up to DN50 ball

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet LH24A-00 Communicative linear actuator adjusting dampers and slide valves in technical building installations Air damper size up to approx. m² Actuating force 50 N Nominal voltage AC/DC

More information

Cover Page - Electric Actuators & Accessories. Standard & Optional Features. OM Actuator Standard Features. OM Actuator Optional Features

Cover Page - Electric Actuators & Accessories. Standard & Optional Features. OM Actuator Standard Features. OM Actuator Optional Features SECTION 5 INDEX DESCRIPTION Cover Page - Electric Actuators & Accessories Standard & Optional Features OM Actuator Standard Features OM Actuator Optional Features V / Actuator Selection Chart OM1 Actuator

More information

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series OpenAir GQD Series Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators Technical Instructions Document No. 155-760 EA GQD Description Features Application The OpenAir GQD Series direct-coupled

More information

LA-5000 SERIES LINEAR VALVE ACTUATORS

LA-5000 SERIES LINEAR VALVE ACTUATORS LA-5000 SERIES LINEAR VALVE ACTUATORS GENERAL DESCRIPTION The LA-5000 Series are bi-directional, linear actuators internally geared to produce up to 6,500 lbs. (28,913 N) of thrust, and offer continuous

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet NM24A- Communicative damper actuator for adjusting dampers in technical building installations Air damper size up to approx. 2 m² Nominal torque Nm Nominal voltage AC/DC 24 V Control

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet GK24G-MF Parameterisable SuperCap damper actuator with emergency control function and extended functionalities in the IP66 protective housing for adjusting dampers in technical building

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

Conductivity Transmitter

Conductivity Transmitter Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Signet 9950 Dual Channel Transmitter

Signet 9950 Dual Channel Transmitter Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for (Gen 2a) or later in Simplified Chinese,

More information

Series 70 24V and 120V Actuator 600 to 18,000 lb.-in.

Series 70 24V and 120V Actuator 600 to 18,000 lb.-in. Application Bray s years of proven success in quarter turn electric actuation, combined with innovative engineering, has produced the modern Series 70. The Series 70 has become the industry standard in

More information

Technical Instructions Document No EA GQD June 23, OpenAir

Technical Instructions Document No EA GQD June 23, OpenAir OpenAir Spring Return, 20 lb-in (2 Nm), Rotary GQD Series, Electronic Damper Actuators Technical Instructions Document No. 155-760 EA GQD Description Features Application The OpenAir GQD Series direct-coupled

More information

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems 3 048 RCU15 Room Temperature Controllers for heating and cooling systems RCU15 Choice of two-position or modulating PI control ON / OFF or PWM outputs for heating and cooling Control depending on room-

More information

Brief description. Type overview

Brief description. Type overview echnical data sheet VAV-Compact KNX A pressure sensor, digital VAV controller and damper actuator all in one, providing a VAV-Compact solution with a communications capability for pressureindependent VAV

More information

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service Product Bulletin Code No. LIT-977319 Issued September 26, 2014 The VA-9070 Series Electric Rotary Actuators for Two-Position

More information

Contents. ensure product integrity and each product manufactured undergoes rigorous testing to guarantee its performance and dependability.

Contents. ensure product integrity and each product manufactured undergoes rigorous testing to guarantee its performance and dependability. Contents More than a quarter of a century s manufacturing experience has gone into every product that carries the Neptronic name. From inspiration to realization, innovation has been the standard in design.

More information

Overview of types. Technical data. T5-NRDVX24-SR-T-.. en v Subject to changes 1 / 3

Overview of types. Technical data.   T5-NRDVX24-SR-T-.. en v Subject to changes 1 / 3 echnical data sheet NRDVX4-SR--.. Modulating short stroke actuator for the motorisation of Cazzaniga and Siemens short stroke valves in HVAC systems Nominal stroke max. 5.5 mm Actuation force 500 Nm Nominal

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet LR24A-KNX Communicative rotary actuator for ball valves Nominal torque 5 Nm Nominal voltage AC/DC 24 V Control modulating Conversion of sensor signals Communication via KNX (S-Mode)

More information

PRODUCT DATASHEET MOTORIZED 2- OR 3-WAY CONTROL VALVES TYPE RH..D..

PRODUCT DATASHEET MOTORIZED 2- OR 3-WAY CONTROL VALVES TYPE RH..D.. PRODUCT DATASEET OTORIZED 2- OR 3-WA COTRO VAVES TPE R..D.. Specialized periphery integrator in VAC IGIGTS Suitable for the control of hot and chilled water (0...+130 C) in VAC systems control of heating

More information

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration

More information

ED701 General Industry Pressure Transmitter

ED701 General Industry Pressure Transmitter ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

Type overview. Technical data

Type overview. Technical data echnical data sheet P..W..EV-BAC Characterised control valve (CCV) with adjustable flow rate and sensor-operated flow control, as well as power and energy-monitoring function, 2-way, with flange PN For

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet SHK24A-MF Parameterisable linear SuperCap actuator with emergency control function and extended functionalities for adjusting dampers and slide valves in technical building installations

More information

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span 2-way motor valve Actuator isolated from flow path Excellent range and fast response times Low power consumption Orifice sizes 1 to 10 mm Versions: Standard, positioner, process controller and high pressure

More information

DCS-62 Series Spring Return Electronic Actuator Product Bulletin

DCS-62 Series Spring Return Electronic Actuator Product Bulletin Delta Control Products, Inc. 0 West Rose Garden Lane Phoenix, Z 807 6-780-08 DCS-6 Series Spring Return Electronic ctuator Product ulletin Description The Delta DCS-6 direct-coupled spring return electronic

More information

AC centrifugal fan. R2E180-AS backward curved, single inlet. Nominal data

AC centrifugal fan.     R2E180-AS backward curved, single inlet. Nominal data Nominal data Type Motor ME68-BF Phase ~ ~ Nominal voltage VAC Frequency Hz 5 6 Type of data definition fa fa Valid for approval / standard CE CE Speed min - Power input W 8 Current draw A.6.5 Motor capacitor

More information

Product Data Sheet 8214 J/2H4P

Product Data Sheet 8214 J/2H4P The engineer's choice 8214 J/2H4P INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical

More information

BONOMI NORTH AMERICA SERIES 500N - 500S

BONOMI NORTH AMERICA SERIES 500N - 500S BOI RTH AERICA SERIES 500N - 500S NYON COATED DISC CF SS DISC anually operated butterfly valves. Epoxy coated cast iron wafer body. Full port sizes / to. EPD resilient seat -0 F to 50 F. API609 face to

More information