Technical data. Safety notes. Power consumption In operation At rest For wire sizing

Size: px
Start display at page:

Download "Technical data. Safety notes. Power consumption In operation At rest For wire sizing"

Transcription

1 echnical data sheet Damper actuator NM4A-SR-P Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air control dampers up to approx. m orque Nm Nominal voltage AC/DC 4 V Control: modulating DC... V, position feedback DC... V echnical data Electrical data Nominal voltage AC 4 V, 5/6 Hz DC 4 V Nominal voltage range AC/DC V Power consumption In operation At rest For wire sizing nominal torque.4 W 4 VA Connection erminals 4 mm (Cable Ø 4... mm, four-core) Functional data orque (nominal torque) Min. nominal voltage Control Control signal Working range DC... V, typical input impedance kω DC... V Position feedback (Measuring voltage) DC... V, max. ma Position accuracy ±5% Direction of rotation Reversible with switch / Direction of rotation at = V At switch position resp. Manual override Gearing latch disengaged with pushbutton, detentable Angle of rotation Max. 95, limited on both sides by means of adjustable, mechanical end stops Running time 5 s / 9 Sound power level Max. 35 db (A) Position indication Mechanical, pluggable Safety Protection class III Safety extra-low voltage Degree of protection IP54 in any mounting position EMC CE according 89/336/EEC Mode of operation ype (to EN 673-) Rated impulse voltage.8 kv (to EN 673-) Control Pollution Degree 3 (to EN 673-) Ambient temperature range C Non-operating temperature C Ambient humidity range 95% r.h., non-condensating (EN 673-) Maintenance Maintenance-free Dimensions / Weight Dimensions See «Dimensions» on page Weight Approx. 8 g Safety notes he damper actuator is not allowed to be used outside the specified field of applica tion, especially in aircraft or any other form of air transport. Assembly must be carried out by trained personnel. Any legal regulations or regulations issued by authorities must be observed during assembly. he device may only be opened at the manufacturer s site. It does not contain any parts that can be replaced or repaired by the user. When calculating the required torque, the specifications supplied by the damper manufacturers (cross section, design, installation site), and the air flow conditions must be observed. he device contains electrical and electronic components and is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed.

2 NM4A-SR-P Damper actuator AC/DC 4 V, Nm Product features Mode of operation Simple direct mounting Manual override he actuator is controlled by means of a standard control signal DC... V. It opens to the position dictated by this signal. he measuring voltage allows the damper position (... %) to be electrically indicated and serves as a follow-up control signal for other actuators. Simple direct mounting on the damper spindle with a universal spindle clamp, supplied with an anti-rotation strap to prevent the actuator from rotating. Manual operation is possible with the pushbutton (the gearing latch remains disengaged as long as the pushbutton is pressed or detented). Adjustable angle of rotation High functional reliability Adjustable angle of rotation with mechanical end stops. he actuator is overload-proof, requires no limit switches and automatically stops when the end stop is reached. Accessories Description Data sheet Electrical accessories Auxiliary switch S..A.. - S..A.. Feedback potentiometer P..A.. - P..A.. Range controller SBG4 - SBG4 Positioner SG..4 - SG..4 Digital position indication ZAD4 - ZAD4 Mechanical accessories Various accessories (clamps, shaft extensions etc.) - Z-NM..A.. Electrical installation Wiring diagram Notes Connection via safety isolating transformer. Other actuators can be connected in parallel. Please note the performance data. 3 5 DC V DC V Dimensions [mm] Dimensional drawings 5 7 6,5 mm 35 mm 4... mm 4 Damper spindle Length Clamp on top > > 8 < 6.7 Clamp on bottom * > 8... > 8 < * Option (Accessory K-NA) NM4A-SR-P en-gb Subject to modification

3 NM..A E Nm mm mm M-NM..A.. v..3 /

4 NM..A.. N L N L 3 3 AC 4 V / DC 4 V DC V (NM7A..) 3 3 S S S3 3 S S S3...% NM4A.. NM7A.. NM4A-S.. NM4AP5.. AC... 4 V N L L 3 N L L 3 S S S3 S S S3 S S S3 NM3A.. NM3A-S.....% AC 4 V / DC 4 V DC V DC V DC V MP NM4A-SR.. NM4A-MF.. NM4A-MP.. DC V (NM7A-SR..) SG..4 5 DC V DC V AC 4 V / DC 4 V (NM4A-V / VR..) 3 5 NM7A-SR.. AC... 4 V N L SG..4 5 DC V DC V VR NM4A-V NM3ASR.. NM4A-V / VR.. / M-NM..A.. v..3

5 M..P / LM..P / NM..P / SM..P / GM..P B mm 35 mm Options mm mm ype ype mm ype max 4 Nm

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet GM4A-SR-P Modulating damper actuator for operating air control dampers in ventilation and airconditioning systems for building services installations For air dampers up to approx. 8

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet SM4A-SR-P Modulating damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. 4 m orque

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet MC4A-SR-F Modulating damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx..4 m orque

More information

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool echnical data sheet LMA-MF-P Multifunctional damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx.

More information

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

Technical data.  T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC echnical data sheet SMASR Modulating damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. 4 m orque Nm

More information

Technical data sheet. Technical data. Safety notes

Technical data sheet. Technical data. Safety notes echnical data sheet LM4A-F Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. m orque 5 Nm Nominal

More information

Technical data. Safety notes

Technical data. Safety notes echnical data sheet M3A-F Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. m orque 5 m ominal

More information

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool echnical data sheet SMA--P Multifunctional damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. m orque

More information

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

Technical data. Safety notes.  T3-LR24A-SR en v Subject to changes 1 / 2 echnical data sheet LR4A-SR Modulating rotary actuator for and -way control ball valves orque Nm Nominal voltage AC/DC 4 V Control: Modulating DC... V Position feedback: DC... V echnical data Safety notes

More information

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing echnical data sheet Rotary actuator LR4A Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage AC/DC 4 V Control: Open/close or -point echnical data Electrical data Nominal voltage

More information

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC echnical data sheet SMA-PC Parameterisable damper actuator for adjusting air dampers in ventilation and air-conditioning systems in buildings Air damper size up to approx. m orque 0 Nm Nominal voltage

More information

Power consumption Operation At rest Wire sizing

Power consumption Operation At rest Wire sizing echnical data sheet NM24P-SR Modulating Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx..6 m 2 orque 8

More information

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2 echnical data sheet Rotary actuator LRA Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage AC... 4 V Control: Open/close or -point echnical data Electrical data Nominal voltage

More information

Overview of types. Technical data. T5-NRDVX24-SR-T-.. en v Subject to changes 1 / 3

Overview of types. Technical data.   T5-NRDVX24-SR-T-.. en v Subject to changes 1 / 3 echnical data sheet NRDVX4-SR--.. Modulating short stroke actuator for the motorisation of Cazzaniga and Siemens short stroke valves in HVAC systems Nominal stroke max. 5.5 mm Actuation force 500 Nm Nominal

More information

Technical data. Parameterisable damper actuator in the

Technical data. Parameterisable damper actuator in the echnical data sheet Parameterisable damper actuator in the IP66 protective housing for or adjusting ad usting air dampers in industrial plants and in technical building installations For air dampers up

More information

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A) echnical Data sheets GRK4A-SR-5 Modulating SuperCap rotary actuator with emergency setting function and extended functionalities for butterfly valves and ball valves with mounting flange ISO 511-F05 orque

More information

Technical data. Safety notes. T5-HT24-SR-T en v Subject to changes 1 / 3

Technical data. Safety notes.   T5-HT24-SR-T en v Subject to changes 1 / 3 echnical data sheet H24-SR- Modulating rotary actuator in connection with a mounting kit for the motorisation of the most common mixing valves in HVAC systems orque 10 m ominal voltage AC/DC 24 V Control:

More information

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque echnical data sheet GK4A- Communicative SuperCap rotary actuator with emergency setting function and extended functionalities for adjusting air dampers in ventilation and air-conditioning systems for building

More information

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return echnical data sheet SF24A- Communicative spring return actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx.

More information

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O echnical data sheet NRF24A-SR-S2(-O) Modulating rotary actuator with emergency function for 2- and 3-way ball valves orque or ue 10 Nm Nominal voltage AC/DC 24 V Control: modulating DC 0... 10 V Position

More information

Functional data Factory settings Variable Settings

Functional data Factory settings Variable Settings echnical data sheet Rotary actuator RF-MF(-O) Multifunctional rotary actuator with emergency control for and 3 way control ball valve orque Nm Nominal voltage AC/DC V Control: Modulating DC... V or variable

More information

Overview of types. Technical data

Overview of types. Technical data echnical data sheet SHA-.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control dampers

More information

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable echnical data sheet S--MF- Multifunctional rotary actuator for butterfly valves orque 00 Nm Nominal volta e V Control: ontrol configurable confi urable Position feedback: configurable Auxiliary u iliary

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet Communicative damper actuator for adjusting dampers in technical building installations Air damper size up to approx. m² Nominal torque 5 Nm Nominal voltage AC/DC 24 V Control Modulating

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet GM24A--P Communicative damper actuator for adjusting dampers in technical building installations Air damper size up to approx. 8 m² Nominal torque 4 Nm Nominal voltage AC/DC 24 V Control

More information

Extension for ground plate Z-SMA. Shaft extension AV8-25. Reversible spindle clamp K-SA. Damper crank arm KH8. Extension from SM.. or AM.. to SM..A..

Extension for ground plate Z-SMA. Shaft extension AV8-25. Reversible spindle clamp K-SA. Damper crank arm KH8. Extension from SM.. or AM.. to SM..A.. echnical data sheet Mechanical accessories for SM..A.. Extension for ground plate Z-SMA Extension from SM.. or AM.. to SM..A.. Galvanized steel Shaft extension AV8-25 Length approx. 250 mm For damper spindles

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet NM24A- Communicative damper actuator for adjusting dampers in technical building installations Air damper size up to approx. 2 m² Nominal torque Nm Nominal voltage AC/DC 24 V Control

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet SM24A--P Communicative damper actuator for adjusting dampers in technical building installations Air damper size up to approx. 4 m² Nominal torque 2 Nm Nominal voltage AC/DC 24 V Control

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet GK24G-MF Parameterisable SuperCap damper actuator with emergency control function and extended functionalities in the IP66 protective housing for adjusting dampers in technical building

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet GR24A--R Communicative Retrofit rotary actuator for rotary valves and butterfly valves Nominal torque 40 Nm Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Position

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet LM24A-KNX Communicative damper actuator for adjusting dampers in technical building installations Nominal torque 5 Nm Nominal voltage AC/DC 24 V Conversion of sensor signals echnical

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet LH24A-00 Communicative linear actuator adjusting dampers and slide valves in technical building installations Air damper size up to approx. m² Actuating force 50 N Nominal voltage AC/DC

More information

Brief description. Type overview

Brief description. Type overview echnical data sheet VAV-Compact KNX A pressure sensor, digital VAV controller and damper actuator all in one, providing a VAV-Compact solution with a communications capability for pressureindependent VAV

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet LR24A-KNX Communicative rotary actuator for ball valves Nominal torque 5 Nm Nominal voltage AC/DC 24 V Control modulating Conversion of sensor signals Communication via KNX (S-Mode)

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet SHK24A-MF Parameterisable linear SuperCap actuator with emergency control function and extended functionalities for adjusting dampers and slide valves in technical building installations

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet SVK24A--PC Communicative globe valve actuator with emergency control function for 2-way and 3-way globe valves Actuating force 1500 N Nominal voltage AC/DC 24 V Control modulating,

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet Communicative RobustLine damper actuator for adjusting dampers in industrial plants and in technical building installations Air damper size up to approx. 2 m² orque motor Nm Nominal

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet LR24A-KNX Communicative rotary actuator for ball valves Nominal torque 5 Nm Nominal voltage AC/DC 24 V Conversion of sensor signals echnical data Electrical data Nominal voltage AC/DC

More information

GMU24. Technical data. Dimensions [mm] For operation of air control dampers in HVAC system Torque: 40Nm Nominal voltage: AC/DC 24V Control: Open/Close

GMU24. Technical data. Dimensions [mm] For operation of air control dampers in HVAC system Torque: 40Nm Nominal voltage: AC/DC 24V Control: Open/Close GMU24 For operation of air control dampers in HVAC system orque: 4m ominal voltage: AC/ Control: Open/Close echnical data Electrical data Functional data Working conditions Dimensions / weight ominal voltage

More information

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Electrical data Nominal voltage AC 230 V Nominal voltage frequency echnical data sheet SY3-30-MP- Communicative rotary actuator for butterfly valves ominal torque 50 m ominal voltage Control modulating, communicative DC (0)...0 V Variable Position feedback DC...0 V Variable

More information

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation Vmax low-n: Vmax for low-noise operation

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation Vmax low-n: Vmax for low-noise operation echnical data sheet EP..R-R6+BAC Characterised control valve with sensor-operated flow control, 6-way, Internal thread, PN 16 (EPIV) Nominal voltage AC/DC 24 V Control modulating, communicative wo sequences

More information

Image. Installation VAV-Universal Retrofit-Set. General Information. Safety notes

Image. Installation VAV-Universal Retrofit-Set. General Information. Safety notes VAV-Universal Retrofit-Set VRD-RE-SET VAV-Universal Retrofit Set for utilisation of existing VAV devices made by various manufacturers. VRD-RE-SET for air velocity up to m/s. Image Suitable only for round

More information

Adaptive control system for duct and room pressure applications. Table of Contents

Adaptive control system for duct and room pressure applications. Table of Contents Product information STP system MP BUS TECHNOLOGY BY BELIMO Adaptive control system for duct and room pressure applications Table of Contents Overview of the system 2 System description 3 Technical data

More information

Type overview. Technical data

Type overview. Technical data echnical data sheet P..W..EV-BAC Characterised control valve (CCV) with adjustable flow rate and sensor-operated flow control, as well as power and energy-monitoring function, 2-way, with flange PN For

More information

Non-Spring Return EconoDrive Proportional Actuator

Non-Spring Return EconoDrive Proportional Actuator MSD-0x3 Series Non-Spring Return EconoDrive Actuator EconoDrive overshaft actuators are designed to provide an economical and reliable solution for many overshaft damper and ball valve requirements. All

More information

Rotary gear motor series AG8...

Rotary gear motor series AG8... Rotary gear motor series AG8... The electric actuator belonging to AG8 series is designed to operate gas valves and air dampers in ventilation and air conditioning systems. The compact design and universal

More information

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control s OpenAir Air damper actuators GDB..1E Electronic motor driven actuators for open-close, three-position and modulating control Nominal torque 5 Nm Operating voltage AC 24 V ~ / DC 24 48 V or AC 100 240

More information

Spring Return DuraDrive Proportional Actuator

Spring Return DuraDrive Proportional Actuator MS40-7043, MS4-7073, MS4-753 Spring Return DuraDrive Proportional Actuator For spring return applications that require proportional modulation control of dampers and valves in HVAC systems. Features: Proportional

More information

LM Series Direct Coupled Actuator

LM Series Direct Coupled Actuator LM Series Direct Coupled Actuator Small Yet Powerful Minimum in-lb torque in a compact package. For damper areas up to 8 sq-ft*. Quiet Plus VAV terminal unit by Warren Technology Areas of Application VAV

More information

Non-Spring Return DuraDrive Modulating Actuator

Non-Spring Return DuraDrive Modulating Actuator MS41-60xx Series n-spring Return DuraDrive Modulating Actuator The DuraDrive direct coupled 24 Vac non-spring return rotary electric actuators are designed for modulating control of dampers. S41-60xx ries

More information

Brief description. VAV-Compact MP en-gb Changes reserved 1. Application. Pressure measurement. Actuator

Brief description.  VAV-Compact MP en-gb Changes reserved 1. Application. Pressure measurement. Actuator Product information VAV-Compact MP A pressure sensor, digital VAV controller and damper actuator all in one, providing a compact solution with a communications capability for pressure-independent VAV and

More information

Configured air damper actuators 6FU11xx-xDxxx-xxxx

Configured air damper actuators 6FU11xx-xDxxx-xxxx s OpenAir Configured air damper actuators 6FU11xx-xDxxx-xxxx Electronic motor driven actuators for open-close, three-position and modulating control Nominal torque 5 Nm Operating voltage AC 24 V ~ / DC

More information

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle s 4 502 ACVATIX Electromotoric rotary actuators for butterfly or slipper valves SAL.. with 90 rotary angle SAL31.. Operating voltage AC 230 V, 3-position control signal SAL61.. Operating voltage AC/DC

More information

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004 Current Monitoring Relay Data Sheet 08/2004 Functions Structure Current monitoring of direct and alternating current in 1-phase networks with settable threshold values, starting override and response delay

More information

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke s 4 509 ACVATIX Electromotoric actuators for valves SAX..P with a 20 mm stroke SAX31P.. Operating voltage AC 230 V, 3-position control signal SAX61P.. Operating voltage AC/DC 24 V, control signal DC 0

More information

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet EP..R+KMP Communicative characterised control valve with sensor-operated flow control and emergency control function, Nominal voltage AC/DC 24 V Control Modulating For closed cold and

More information

GM24-MFT US. Proportional damper actuator, non-spring return, Multi-Function Technology

GM24-MFT US. Proportional damper actuator, non-spring return, Multi-Function Technology GM-MFT US Proportional damper actuator, non-spring return, Multi-Function Technology GM-MFT US Torque min. 0 in-lb Control to 0 VDC (DEFULT) Feedback to 0 VDC (DEFULT) pplication For proportional modulation

More information

SAX.. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

SAX.. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke s 4 501 ACVATIX Electromotoric actuators for valves SAX.. with a 20 mm stroke SAX31.. Operating voltage AC 230 V, 3-position control signal SAX61.. Operating voltage AC/DC 24 V, control signal DC 0 10

More information

E Series 9.00 (1/2) E series

E Series 9.00 (1/2) E series Clamp-on AC/DC current probes E Series The clamps use Hall effect technology for the measurement of AC and DC currents from several milliamps to over 100 A. The elongated, narrow design of these clamps

More information

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force 4 584 ACVATIX Electromotoric actuators for valves SAT.. with a 5.5 mm stroke and 300 N positioning force SAT31.. Operating voltage AC 230 V, 3-position control signal SAT61.. Operating voltage AC/DC 24

More information

Air damper actuators Rotary version with spring return, AC 24 V / DC V / AC 230 V

Air damper actuators Rotary version with spring return, AC 24 V / DC V / AC 230 V 4 614 OpenAir T Air damper actuators Rotary version with spring return, / DC 24 48 V / AC 230 V GA..1 Electronic motor driven actuators for two-position, three-position, and modulating control, nominal

More information

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet EP..R+MOD Communicative characterised control valve with sensor-operated flow control, 2-way, internal thread (EPIV) Nominal voltage AC/DC 24 V Control communicative For closed cold

More information

Air damper actuators. OpenAir GSD...1A. Electric motor-driven rotary actuators for open-close, three-position and modulating control

Air damper actuators. OpenAir GSD...1A. Electric motor-driven rotary actuators for open-close, three-position and modulating control s OpenAir Air damper actuators SD...1A Electric motor-driven rotary actuators for open-close, three-position and modulating control 2 m nominal torque Operating voltage / DC 24 48 V or AC 100 240 V ~ Prewired

More information

Rp [ ] [ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Rp [ ] [ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet EV..R+BAC Characterised control valve with sensor-operated flow rate or power control, power and energy-monitoring function, 2-way, Internal thread, PN 16 (Energy Valve), Nominal voltage

More information

Explosion proof rotary actuator - On/Off or programmable regulating actuator

Explosion proof rotary actuator - On/Off or programmable regulating actuator Explosion proof rotary actuator - On/Off or programmable regulating actuator Direct mounting for quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Type 3004 can

More information

GLB...9. Ball Valve actuators. Building Technologies HVAC Products. for valves VAI61... AC 24 V / AC 230 V

GLB...9. Ball Valve actuators. Building Technologies HVAC Products. for valves VAI61... AC 24 V / AC 230 V 4 657 Ball Valve actuators GLB...9 for valves VAI61... / Electronic motor driven actuators for three-position and modulating control, pre-wired with 0.9 m long connection cables. Remarks This data sheet

More information

Electronic Air / Fuel Ratio Control System

Electronic Air / Fuel Ratio Control System 7 871 ISO 9001 Electronic Air / Fuel Ratio Control System RVW20... Electronic control unit - for use with modulating single- and dual-fuel burners - with extended functionality for mechanical air / fuel

More information

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke s 4 501 ACVATIX Electromotoric actuators for valves SAX.. with a 20 mm stroke SAX31.. Operating voltage AC 230 V, 3-position control signal Operating voltage AC/DC 24 V, control signal DC 0 10 V, 4 20

More information

Power supply CP-D 24/1.3

Power supply CP-D 24/1.3 2CDC 271 027 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 24 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 1.3 A Rated output power

More information

Any installation position possible. 1K5, but C. < 2 % of the control range. < 0,2 % / 0,1 bar, type 824.P < 0,1 % / 0,1 bar. Approx.

Any installation position possible. 1K5, but C. < 2 % of the control range. < 0,2 % / 0,1 bar, type 824.P < 0,1 % / 0,1 bar. Approx. General data Mounting Enclosure material On linear actuators On quarter-turn actuators ARCA-integrated or acc. to IEC 534-6 (NAMUR) Range of stroke 10... 120 mm ARCA-integrated or acc. to VDI/VDE 3845

More information

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke s 4 501 ACVATIX Electromotoric actuators for valves SAX.. with a 20 mm stroke SAX31.. Operating voltage AC 230 V, 3-position control signal SAX61.. Operating voltage AC/DC 24 V, control signal DC 0 10

More information

MODEL: MRP6. Final Control Elements

MODEL: MRP6. Final Control Elements Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator Electrical positioner incorporated 1/1000 high resolution Easy adjustment: electronic

More information

Power supply CP-E 24/0.75

Power supply CP-E 24/0.75 2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output

More information

M7061 ROTARY VALVE ACTUATORS

M7061 ROTARY VALVE ACTUATORS M0 ROTARY VALVE ACTUATORS PRODUCT DATA FEATURES Protected against overload and blocking Maintenance-free electrical actuator for rotary valves Clear position indicator Direct mounting on rotary valves

More information

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet 2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer

More information

AE SERIES ACTUATORS. Electric Actuators. Standard Voltages 110/240/380/480V 24VAC/24VDC. Modulating Capable. 100% Duty Cycle Models Fast Acting Models

AE SERIES ACTUATORS. Electric Actuators. Standard Voltages 110/240/380/480V 24VAC/24VDC. Modulating Capable. 100% Duty Cycle Models Fast Acting Models AE SERIES ACTUATORS Electric Actuators Standard Voltages 110/240/380/480V 24/24VDC Modulating Capable 100% Duty Cycle Models Fast Acting Models Max-Air Technology, Inc. 751 Hoff Rd O Fallon, Missouri 63366

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

SAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke

SAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke s A6V10628469 ACVATIX Electromotoric actuators for valves SAY..P.. with a 15 mm stroke SAY31P03 Operating voltage AC 230 V, 3-position control signal Operating voltage AC/DC 24 V, control signal DC 0 10

More information

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke s A6V10628469 ACVATIX Electromotoric actuators for VPI46 SAY..P.. with a 15 mm stroke Operating voltage AC 230 V, 3-position control signal Operating voltage AC/DC 24 V, control signal DC 0 10 V, 4 20

More information

Power supply CP-E 24/20.0

Power supply CP-E 24/20.0 2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output

More information

27/04/2015

27/04/2015 Modular Carril DIN 35 mm HIL Part number 84871120 Control of AC and DC currents Automatic recognition of AC/DC Measurement ranges from 2 ma to 10 A Choice between over and undercurrent True RMS measurement

More information

Type 3374 Electric Actuator

Type 3374 Electric Actuator Type 3374 Electric Actuator Application Electric actuator for plant engineering and HVAC The actuator is a linear actuator with or without fail-safe action available either in a version with a three-step

More information

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet 2CDC 271 028 F0008 OUTPUT L+, L+, L-, L-: terminals - output Features Rated output voltage 48 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 5 A Rated

More information

CR24-.. Single room controllers

CR24-.. Single room controllers Product information CR4- CR4- Single room controllers Table of contents wwwbelimocom Overview of the system Overview of functions 3 Technical data sheets CR4-B1 / CR4-A1 Single room controllers CR4-B /

More information

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC P AC/DC voltage monitoring Multifunction Supply voltage 24 V DC or 230V AC/DC Supply circuit = Measuring circuit 1 change-over contact Width 22,5 mm Control elements Tripping delay Maximum threshold Minimum

More information

SERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A.

SERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A. Pinces Current ampèremetriques clamps for AC/DC pour current courant AC SERIE E N The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over

More information

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet 1SVR 430 103 F0200 CT-ERS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the

More information

SINEAX U 553 Transducer for AC Voltage

SINEAX U 553 Transducer for AC Voltage With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U 55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load

More information

COMMERCIAL. GA Series - Actuator Operating Instructions. GA Non-Spring Return Actuator - (GA24-562) 04/08 /15

COMMERCIAL. GA Series - Actuator Operating Instructions. GA Non-Spring Return Actuator - (GA24-562) 04/08 /15 COMMERCIAL Bray Controls Commercial Diision 13788 West Road, Suite 200A Houston, Texas 77041 BCDSales@Bray.com Phone: 1-888-412-2729 Fax: 1-888-412-2720 www.braycommercialdiision.com GA Series - Actuator

More information

Electromotoric actuators for stroke valves

Electromotoric actuators for stroke valves s ACVATIX Electromotoric actuators for stroke valves SAS.. Electromotoric actuators with 5.5 mm stroke and 400 N positioning force SAS31.. Operating voltage AC 230 V, 3-position control signal Operating

More information

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator 1/1 high resolution Easy adjustment: electronic limiter at the valve open & closed

More information

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC 2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from

More information

Rotary actuators for ball valves

Rotary actuators for ball valves s ACVATIX Rotary actuators for ball valves GLB..9E Electromotoric rotary actuators for open-close, three-position or modulating control. Used in heating, ventilation and air conditioning plants. For 2-port

More information

Installation of VAV-Compact Retrofit with ZDMS-..

Installation of VAV-Compact Retrofit with ZDMS-.. Installation of VAV-Compact Retrofit with ZDMS-.. LMVAX-D3-MP NMVAX-D3-MP ZDMS-.. VAV-Compact Retrofit for utilisation of existing VAV devices made by various manufacturers. for various air velocities

More information

Specification GRUNER YSP 227C

Specification GRUNER YSP 227C Specification 227CM & CMX Written by: Dillinger Kevin Issue 1 Date: 26.03.2013 14:11:00 Side 1 of 35 TOC Seite 1. Additional information... 3 1.1. Preamble... 3 1.2. Version... 3 2. General Description...

More information