Primary winding current transformer, type WSK
|
|
- Patricia Boyd
- 6 years ago
- Views:
Transcription
1 Technical documentation winding transformer, type DEIF /S Frisenborgvej 33 DK-7800 Sive Tel.: Fax: Document no.: D
2 Current transformers overview Clic on a product name or chec mar to jump to information page. Page Page nominal 30* 40* 40 N* N 31.5 nominal conductor in mm Round conductor in mm Transform. width in mm * For the transformers above, clic-on mountings are available for fitment onto 35mm DIN-rails (DIN 50022). conductor in mm Round conductor in mm Transform. width in mm 2
3 winding transformer Based on the physical operating principle of transformers, the required core volume transferring an amount of power, increases rapidly with a decreasing nominal. s there are limits on increasing the transformer size, winding transformer are being used. Interim transformers also belong to the group of winding transformer. This construction is mainly used for primary s of up to 10, and achieves a transformation at a higher or lower secondary values. In addition to their application in adapting a measuring circuit on existing measuring units, interim transformers are being used also for lowering the power loss by the transmission of analogically measured values over great distances. This is made possible by means of a squared dependence of the power loss from the flowing. PV = I 2 Z[V] apparent power [V] This means when the original nominal is halved, the conductor loss drops down to 25% of its original value. Indication: The selection of the nominal power of the initially activated main transformer is achieved through the application of the following measurement comparisions. 2 I P GH = P Z ( 2 ) I 1 + P E + P HZ P GH P Z P E P HZ I 1 I 2 apparent power of the main transformer secondary performance of the interim transformer (nominal performance inclusive of conductor losses) consumption of the interim transformer by nominal conductor losses between main- and interim transformer by nominal primary nominal of the interim transformer secondary nominal of the interim transformer 3
4 winding transformer 30 Secondary ccuracy class ccuracy class V rt.-no. rt.-no. rt.-no. rt.-no (1.3 7 ) (1.1 8 ) (1.8 5 ) (2.4 4 ) (2.4 0 ) l (3.0 9 ) (2.9 7 ) - P 1 M a d e in G erm any x x x x x x x xxx xxx (2.3 6 ) g ( lbs) DIN rail mounting Item number: Sealed shutter Type:
5 winding transformer 40 Secondary (1.7 7 ) (1.5 7 ) (2.2 4 ) (2.8 3 ) ccuracy class ccuracy class V rt.-no. rt.-no. rt.-no. rt.-no (2.7 9 ) l (3.4 8 ) (3.3 6 ) - P 1 M a d e in G erm any x x x x x x x xxx xxx (1.9 7 ) (2.7 5 ) g ( lbs) DIN rail mounting Item number: Sealed shutter Type:
6 winding transformer 40 N Secondary ccuracy class ccuracy class V rt.-no. rt.-no. rt.-no. rt.-no (2.1 6 ) (1.9 6 ) (2.6 7 ) (3.2 2 ) (2.7 7 ) l (4.3 3 ) (4.3 1 ) - P 1 M a d e in G erm any x x x x x x x xxx xxx (1.9 6 ) (2.7 5 ) g ( lbs) DIN rail mounting Item number: Sealed shutter Type:
7 winding transformer 60 Secondary (1.7 7 ) ccuracy class ccuracy class V rt.-no. rt.-no. rt.-no. rt.-no (2.3 6 ) (3.0 3 ) (3.6 2 ) (2.7 9 ) L (1.9 7 ) (2.7 5 ) g ( lbs) DIN rail mounting Not available Sealed shutter Type:
8 winding transformer 70.6 N Secondary (1.7 7 ) (2.3 6 ) (3.0 3 ) (3.6 2 ) (2.7 9 ) ccuracy class ccuracy class V rt.-no. rt.-no. rt.-no. rt.-no. V e d M 8 x 2 5 m m M 1 0 x3 0 m m (3.4 8 ) (3.3 6 ) L L (1.3 7 ) (1.9 6 ) (2.7 5 ) (3.3 8 ) (4.5 6 ) (5.3 5 ) g ( lbs) DIN rail mounting Not available Sealed shutter Type:
9 winding transformer 31.5 Secondary (1.6 9 ) L -H 2 -P (1.9 6 ) (2.7 6 ) (2.5 2 ) ccuracy class ccuracy class V rt.-no. rt.-no. rt.-no. rt.-no L (1.2 2 ) (3.9 3 ) (2.0 4 ) (2.5 5 ) (3.6 2 ) (4.5 2 ) g ( lbs) DIN rail mounting Not available Sealed shutter Type:
10 Current transformers ccessories for DCT Test certificate On request, we can provide you with a test certificate for a specific transformer along with the CT. Please inform us when placing your order. Sealed shutter On request, we can supply a transparent plastic cover. The cover seals the connections on the CT in a way that leaves the type label visible. Please chec availability on each individual data sheet. Excitation curve On request, we can provide you with an excitation curve for a specific transformer along with the CT. Please inform us when placing your order. Optional frequency Frequency range for a standard CT is 50-60Hz. On request, we can provide you with a frequency range from 16 2/3 400Hz. Please inform us when placing your order. Cast resin Cast resin is standard for all CT s with a nominal >4,000. On request, all CT s with a nominal <4,000 can be produced with cast resin. Please inform us when placing your order. The min. and max. weight specification for each type refers to standard versions. The specification is different if cast resin is ordered for CT s <4,000. Mounting Foot angle for screw mounting and busbar mounting screws with isolating protection caps are supplied along with the CT. DIN-rail mounting for tubes, plug-ins and protection transformers is available on request for certain CT types. Please chec availability on each individual data sheet. 10
Summation current transformers, type KSU/SUSK
Technical documentation Summation transformers, type KSU/SUSK DEIF /S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4921210113E Data sheet
More informationDATA SHEET Selectable AC transducer TAS-311DG
DATA SHEET Selectable AC transducer Measuring on AC networks Class 0.5 (IEC688) measurement Supply/measur. voltage up to 690 V Easy configuration via PC interface possible DEIF A/S Frisenborgvej 33 DK-7800
More informationDATA SHEET AC current single function transducer TAC-311DG/TAC-321DG
DATA SHEET AC current single function transducer TAC-311DG/TAC-321DG Compact design, 55 x 75 mm Easily accessible terminals Accuracy class 0.5 35 mm DIN rail or base mounting DEIF A/S Frisenborgvej 33
More informationDATA SHEET Reverse power relays, RMP-121D ANSI code 32
DATA SHEET Reverse power relays, RMP-121D ANSI code 32 Protection against "motoring" Single phase measurement LED indication of fault condition Timer-controlled tripping LED indication for activated relay
More informationDEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions
Installation and start up instructions TAS-311DG Selectable AC transducer Voltage, current, frequency or phase angle transducer Supply voltage up to 690V DEIF A/S Configuration via PC-interface possible
More informationDATA SHEET Differential current relays, RMC-131D ANSI code 87
DATA SHEET Differential current relays, RMC-131D ANSI code 87 Measurement of 3-phase currents Non-stabilised measurement Timer-controlled tripping Extra change-over relay contact for signalling DEIF A/S
More informationRMV-122D, RMV-132D ANSI
DATA SHEET Voltage relays, RMV-112D, RMV-122D, RMV-132D ANSI codes 27/59, 59, 27 Under-voltage/over-voltage 3-phase measurement LED indication of fault condition Timer-controlled tripping LED indication
More informationInstallation and start up instructions. Synchroniser type FAS-115DG uni-line H (UK) Synchronisation of generator to busbar
Installation and start up instructions Synchroniser type FAS-115DG uni-line Synchronisation of generator to busbar With voltage matching Circuit breaker time compensation LED indication of status DEIF
More informationProtection relays and controllers. Types TRANSAL DC-2TF, ACV-3TF, ACI-3TF, PFC-2TF TRANSAL DC-2TB, AVC- 3TB, ACI-3TB, PFC-2TB
Protection relays and controllers Types TRANSAL DC-2TF, ACV-3TF, ACI-3TF, PFC-2TF TRANSAL DC-2TB, AVC- 3TB, ACI-3TB, PFC-2TB 4921250026C Transal TF Transal TB DEIF A/S Available for the following inputs:
More informationInstallation and start up instructions. Paralleling relay type HAS-111DG uni-line G (UK) Synchronisation of generator to busbar
Installation and start up instructions Paralleling relay type HAS-111DG uni-line 4189340146G (UK) Synchronisation of generator to busbar Setting of phase angle difference Setting of frequency and voltage
More informationInstallation and start up instructions. Synchroniser type FAS-113DG uni-line F (UK) Synchronisation of generator to busbar
Installation and start up instructions Synchroniser type FAS-113DG uni-line Synchronisation of generator to busbar Circuit breaker time compensation LED indication of status LED indication for activated
More informationTransducers for AC measurement. Types TAP, TAQ, TMF, TAA, TAV, TAC. Measurement of: watt, var, frequency, phase angle, voltage, current
Transducers for AC measurement Types TAP, TAQ, TMF, TAA, TAV, TAC 4921220002E Measurement of: watt, var, frequency, phase angle, voltage, current DEIF A/S Accuracy class 0.5 For mounting on DIN rail Compact
More informationDATA SHEET. Paralleling relays, HAS-111DG ANSI code 25
DATA SHEET Paralleling relays, ANSI code 25 Synchronisation of generator to busbar Setting of phase angle difference Setting of frequency and diff. LED indication of status LED for synchronising signal
More informationDATA SHEET. CIO multi-inputs. CAN bus-based I/O module
DATA SHEET CAN bus-based I/O module 8 multi-functional inputs Selectable as: o Digital input, 0(4) to 20 ma, 0 to 10 V, RMI, Pt100, Pt1000, Thermocouple type E, J, K, N, R, S or T Wire break detection
More informationDEIF A/S. User s manual. Read synchroscope type RSQ-3. Precision LED synchronoscope. High immunity to harmonic distortion F (UK)
User s manual Read synchroscope type RSQ-3 4189340264F (UK) Precision LED synchronoscope High immunity to harmonic distortion DEIF A/S DEIF A/S Tel.: (+45) 9614 9614 Frisenborgvej 33, DK-7800 Skive Fa:
More informationAutomatic synchronising relay
Synchronising relays Types FAS-2N, FAS-3N, HAS-2N 4921250029D FAS-3N High accuracy (±3 el.) and fast synchronisation DEIF A/S Circuit breaker time compensation Test switch Voltage matching (type FAS-3N)
More informationDEIF A/S. Application note. Generators parallel with mains Multi-line 2 version 2. Application description. Power import control. Power export control
Generators parallel with mains Multi-line 2 version 2 4189340363B Application description Power import control DEIF A/S Power export control DEIF A/S, Frisenborgvej 33 Tel.: +45 9614 9614, Fax: +45 9614
More informationDATA SHEET. Voltmeters and Ammeters,
DATA SHEET Voltmeters and Ammeters, Moving Coil (type ) Q48, Q72, Q96, Q144 90 or 240 pointer Accuracy class 1.5 Exchangeable scale (type x) Document no.: 4921210012S Application: Moving-coil instruments
More informationDATA SHEET. Switchboard instruments,
DATA SHEET Switchboard instruments, types Standard DIN sizes Quadratic instruments: Q48 Q144 Edgewise instruments: 48 x 24 144 x 72 mm Slim edgewise instruments: 72 x 24 144 x 36 mm Accuracy class 1.5
More informationFunction. Adjustment. Extra functions included. Modes. Housing
Electronic Electronic potentiometer potentiometer DATA DATA SHEET SHEET Function Replaces normal motor potentiometers Adjustment Integrating time (like variable gearboxes) Output start value Output end
More informationDEIF A/S. Application Notes. MDR-2 test procedures. Test of current measurement. Test of differential current measurement.
MDR-2 test procedures 4189340423A MDR-2 SW version 1.1 and later Test of current measurement Test of differential current measurement DEIF A/S Test of trip DEIF A/S, Frisenborgvej 33 Tel.: +45 9614 9614,
More informationMBS AG. KBR 18 Split-core current transformer. Further information about our new split-core current transformer KBR 18: Dimensions:
KBR 18 Split-core current transformer Dimensions: Round conductor: 18 mm Transformer width: 41.6 mm Transformer height: 64.5 mm Transformer depth incl. fixing clasps: 67.3 mm General technical specifications:
More informationInstallation and start up instructions. Detection of vector shift. Detection of over- and underfrequency. Generator disconnection on mains failure
Installation and start up instructions G59 Relay Package uni-line 4189340236C (UK) Detection of df/dt (rate of change of frequency R.O.C.O.F.) Detection of vector shift Detection of over- and underfrequency
More informationAccessories. Accessories
Accessories Accessories Voltage transformer Voltage transformer Powerful and precise Input, 3-pole Output is 3-pole + N Use in IT networks without neutral line For reducing the measurement voltage for
More informationMODEL AT-10 ANALOG TRANSMITTER
MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca
More informationData Sheet. Summation Current Transformer. RISH SUMMATION CT : RISH XMER Sigma. RISH XMER Sigma. Page 1 of 5 00 / 1213
RISH SUMMATION CT RISH XMER Sigma Data Sheet RISH XMER Sigma Summation Current Transformer Tel. +91 253 2202160, 2202202 Fax +91 253 2351064 E-mail India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in
More informationCurrent / residual current and voltage transformers. Current / residual current and voltage transformers
Current / residual current and voltage transformers Current / residual current and voltage transformers 1 Overview Current transformer overview DIN rail current transformer with fuse Current transformer...
More informationDEIF A/S. Insulation monitor. Type SIM-Q
Insulation monitor 4921232C Monitoring of insulation resistance on ungrounded AC networks (IT network) Working voltage up to 69V AC, withstands up to V DC Measuring range 1...Mohm or 1...Mohm Alarm on
More informationPowered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers
Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters CURRENT TRANSFORMERS Current Transformers Analogue Panel Meters Shunts Digital Multimeters
More informationTCM-2 Thyristor Control Module DATA SHEET
TCM-2 Thyristor Control Module TCM-2 Thyristor DATA DATA SHEET Control Module DATA SHEET Insulation monitors, Warning delay and power-up delay Indication of set point on front Measuring range up to 440
More informationAngle position transmitter Type RT-2 Marine bridge instrumentation C (UK) Measuring output: DC current signal 0..20mA or 4..
Installation instructions Angle position transmitter Type RT-2 Marine bridge instrumentation DEIF A/S Analogue output for direct connection of one or more indicators Measuring output: DC current signal
More informationSection 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5
LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section 2, Calibration Calculations... 7 Calibration Procedure... 8 Section
More informationDEIF A/S. Description of options. Option H3 Serial communication Profibus DP Multi-line 2 version 2. Description of option. Functional description
Description of options Option H3 Serial communication Profibus DP Multi-line 2 version 2 4189340279I SW 2.42.X Description of option Functional description DEIF A/S Parameter table Data tables DEIF A/S,
More informationSeries P. Applications
Ratings 25 800 VA Voltage Primary 230 / 400 / 460 V range Secondary 6 / 12 V 12 / 24 V 24 / 48 V 115 / 230 V Voltage selection by means of metal connection bridges, offering the full rated power at any
More informationInstallation and Operating Manual
GB Analog Weight Transmitter PS-1000 Installation and Operating Manual LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section
More informationRISH Ducer E13 3 channel transducer for AC current and voltage
RISH Ducer E13 3 channel transducer for C current and voltage The RISH Ducer E13 ( Fig. 1) converts 3 sine wave C current or C voltage into 3 output signals that can serve several receiving instruments
More informationData Sheet. Summation Current Transformer OMEGA SUMMATION CT : SIGMA SERIES. Page 1 of 5 00 / 1213
OMEGA SUMMATION CT : SIGMA SERIES Data Sheet Summation Current Transformer Page 1 of 5 Omega Summation current transformers are designed to summarize several synchronous Alternating Currents of equal phase
More informationElectronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X
RA 29 934/0.98 Electronic amplifier for the control of proportional valves without position control Model T 3024, Series 3X RA 29 934/2.9 The amplifier T 3024-3X is suitable for the control of pilot operated
More informationNo-wear isolation of potentials in terminal block design
TERMOPTO Overview No-wear isolation of potentials in terminal block design Space saving solid-state relay with PUSH IN connection technology The TERMOPTO opto modules are characterised by a particularly
More informationMeasuring current transformers of the W, W series
Measuring current transformers of the W, W -8000 series W(-8000)_D00078_01_D_XXEN/09.2015 Measuring current transformers of the W, W -8000 series Product description The highly sensitive W and W -8000
More informationShort-circuit-proof switching amplifier for inductive loads up to 10 A
MICROOPTO Overview Short-circuit-proof switching amplifier for inductive loads up to 10 Powerful, compact solid-state relay with error signalling contact The MICROOPTO family offers the customer high-quality
More information400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)
MODEL EM4000ACF Multifunction Transducer for alternating voltage and current Power supply voltages: Suitable for DIN-rail mounting 85 240Vac 400,440Vac 24 65Vdc 100..330Vdc V, A, W, VA, var, Hz, V, Avg.
More informationGeneral Specifications
General Specifications GS J08X0-0E FX Series Computing Units (Variable/Fixed Software Type) Moving Average Unit, Dead Time Unit, Velocity Unit, First Order Lug Unit, First Order Lead Unit, Velocity Limiter,
More informationData Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2
Data Sheet 066.8e Transducers for Active and Reactive Power EW 2.2 DGW 2.2 VGW 2.2 DUW 2.2 VUW 2.2 Application The E/DG/VG/DU/VU W 2.2 power transducers convert all forms of active and reactive power polarity
More informationGeneral Specifications
General Specifications GS J0X02-01E WX2 Series Computing Units (Variable/Fixed Software Type) Moving Average Unit, Dead Time Unit, Velocity Unit, First Order Lug Unit, First Order Lead Unit, Velocity Limiter,
More informationOutput of three-phase motors at 50 Hz and 400 V
RT0, RH Coupling Relays (Interfaces) Description DC operation IEC 0 947 and EN 0 947 (VDE 00) The RT0 coupling relays for switching motors and RH for auxiliary circuits are laid out to the special requirements
More informationInstrument transformers for indoor applications. Product overview. Instrument transformers for indoor applications.
Instrument transformers for indoor applications Product overview Instrument transformers for indoor applications Product overview 2 I N S T R U M E N T T R A N S F O R M E R S F O R I N D O O R A P P L
More informationMEDIUM VOLTAGE PRODUCT. TJP 6.1, TJP 6.2 Indoor voltage transformers
MEDIUM VOLTAGE PRODUCT TJP 6.1, TJP 6.2 Indoor voltage transformers 2 TJP 6.1, TJP 6.2 INDOOR VOLTAGE TRANSFORMERS Parameters Highest voltage for equipment Power frequency test voltage, 1 min. Lightning
More information3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.
3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2 (Code 7 71 071 to 7 71 083) INSTRUCTION MANUAL ( M 981 200 / 00 A ) (c) CIRCUTOR S.A. ----- MKT- MKT2 - ELECTRONIC METERS -------- M-981 200 --- Page Nº 2 3
More informationDEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF
/ LF Insulation monitor Monitoring of insulation resistance on ungrounded AC networks (IT network) Working voltage up to 69V AC, withstands up to V DC Measuring range...kω or 1...MΩ Working frequency down
More informationMEDIUM VOLTAGE PRODUCT. TJP 7.x Indoor voltage transformers
MEDIUM VOLTGE PRODUCT TJP 7.x Indoor voltage transformers 2 TJP 7.X INDOOR VOLTGE TRNSFORMERS Parameters Highest voltage for equipment Power frequency test voltage, 1 min. Lightning impulse test voltage
More informationMODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]
MODEL: MMNV Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels
More informationElectronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback
RA 29 939/06.98 Electronic Amplifier Model T 301 and T 3018 (Series 3X) for the control of proportional directional valves, without positional feedback RA 29 939/06.98 Replaces: 09.94 Electronic amplifier
More informationULTRASTAB IHF Precision Current Transducer
ULTRASTAB 867-200IHF Precision Current Transducer The Ultrastab 867-200IHF Current Transducer is a model in the Ultrastab Current Transducer program. It is the second generation of current transducers
More informationPRODUCT FOR HIGH VOLTAGE APPLICATION. Current transformers for Gasinsulated. Instructions for installation, use and maintenance
PRODUCT FOR HIGH VOLTAGE APPLICATION Current transformers for Gasinsulated switchgear type ELK Instructions for installation, use and maintenance 2 CURRENT TRANSFORMERS FOR GAS-INSULATED SWITCHGEAR TYPE
More informationULTRASTAB I U Precision
ULTRASTAB 867-700I 867-700U Precision Current Transducer The Ultrastab 867-700I and 867-700U Current Transducers, are the latest models of the Ultrastab Current Transducers. They are the third generation
More informationMODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]
Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels CE marking
More informationElectronic timer CT-SDS.22
CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication
More information3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket
41 Low profile PCB relays 8-12 - 16 41 1 & 2 Pole - Low profile (15.7 mm height) 41.31-1 Pole 12 (3.5 mm pin pitch) 41.52-2 Pole 8 (5 mm pin pitch) 41.61-1 Pole 16 (5 mm pin pitch) PCB mount - direct or
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS IMD Manager IMD 100 DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: 9614 9615 Info@deif.com www.deifwindpower.com 4189360018 Rev.: A Date: 2016-12-22 Language:
More informationPOWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL
POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK PP, PP and PB ISO 900 C E R T Y F I K A T 4 mm SERVICE MANUAL Contents Page. APPLICATION... 2. BASIC REQUIREMENTS.... TRANSDUCER SET... 4 4. TECHNICAL
More informationXP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)
XP2-R Power and reverse power relay (January 2006) Manual XP2-R (Revision New) Woodward Manual XP2-R GB Woodward Governor Company reserves the right to update any portion of this publication at any time.
More informationW DATA SHEET Current Transformer 40 x 10, A
W DATA SHEET Current Transformer 40 x 10, 250 600A W SCHRACK-INFO Current transformers for low-voltage network accuracy Single-phase current transformer Passing cable/ bus bar primary Primary current 250
More informationGeneral Specifications
General Specifications GS J0X-0E Model MXT Universal Computing Unit (-input, Isolated -output Type) General This plug-in type universal computing unit receives DC current or DC voltage signals, applies
More informationAUTOMOTIVE CURRENT TRANSDUCER HAB 60-S/SP5
AUOMOIVE CURREN RANSDUCER HAB 60-S/SP5 Introduction he HAB Family is best suited for DC, AC or pulsed currents measurement in high power and low voltage automotive applications. It s contains galvanic
More informationEnergy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302
Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Direct connection up to 65 A (WSx10x) Connection with current transformer (WSx30x) Industrial or meters
More informationPRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID
RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A
More informationProduct Information Measuring resistor with the Pt100-sensor referring to DIN EN Pt100, Pt500, Pt1000
Platinum sensor probe - Basic information The Pt100-sensor is used for precise temperature monitoring applications, where errors in measurement have to be excluded. The linear relationship of the resistor
More informationXP2-R Power and Reverse Power Relay
XP2-R Power and Reverse Power Relay Manual XP2-R (Revision C) Woodward Manual XP2-RE Woodward reserves the right to update any portion of this publication at any time. Information provided by Woodward
More informationOption D1 Voltage/var/cos phi control Description of option Functional description
MULTI-LINE 2 DESCRIPTION OF OPTIONS Option D1 Voltage/var/cos phi control Description of option DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com
More informationMEDIUM VOLTAGE PRODUCT. TJP 5.x Indoor voltage transformers
MEDIUM VOLTAGE PRODUCT TJP 5.x Indoor voltage transformers 2 TJP 5.X INDOOR VOLTAGE TRANSFORMERS 01 Voltage transformer TJP 5.1 and TJP 5.2 with suitable fuses Parameters Highest voltage for equipment
More informationRING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS USER MANUAL
RING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS F.T.M. S. r. l. Fabbrica trasformatori di misura Via Po, 3 20090 Opera MI - Italy Tel : +39 (0)2 576814 Fax : +39 (0)2 57605296 E-mail: info@ftmsrl.it
More informationModular step relays 16 A
Automation for blinds, grilles and shutters Lighting control in corridors (for hotels, offices and hospitals) Bedroom light control Living room light control SЕRIES FINDER reserves the right to alter characteristics
More informationOperating Instruction
Level and Pressure Operating Instruction VEGASEL 643 6 5 + + 3 5 + + max. min. on VEGASEL 643 5 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 1 Product description 1.1 Function
More informationRI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters
RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA
More informationDZD 92 L. Wiring diagram. Time domains. Function. Dimensional drawing. Indicators. Accessories
DZD 92 L Multi-Function - Multi-domain time relay Mono voltage 8 Functions Setting range 0.05 s to 100 h subdivided into 7 time domains 1 immediate-action and 1 time contact or 2 time contacts (adjustable)
More informationCROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM
CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and
More informationInstallation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN
Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas Mimablad: 176GB/1999-10-25 Ersätter: MG-1000-EEx USAGE MG-1000-EEx is suitable for use in measurement
More informationElectronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X
Electronic amplifier for the control of proportional valves without position control Model T 3006, Series 3X RA 29 926/06.98 Replaces: 02.96 The amplifier T 3006-3X is suitable for the control of pilot
More informationMCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description
Universal current transducer Data sheet 104059_en_05 PHOENIX CONTACT 2011-03-09 1 Description MCR-SL-CUC-...-I and MCR-SL-CUC-...-U active current transducers convert DC, AC, and distorted currents into
More informationMedium-voltage transfomers
Medium-voltage transfomers We make energy measurable and take care of your future www.mbs-ag.com Page 2 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com Contents Technical characteristics From page 4 Current
More informationThree-phase monitoring relays CM-PVS.81
Data sheet Three-phase monitoring relays CM-PVS.81 The three-phase monitoring relay CM-PVS.81 monitors the phase parameters phase sequence, phase failure as well as over- and undervoltage. The device is
More informationCROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM
CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and
More informationFeed back element in high performance gradient amplifiers Feed back element in precision current regulated power supplies
ULTRASTAB 866 Precision Current Transducer The Ultrastab 866 Current Transducer is the most proven fluxgate transducer with onboar electronics in the Danfysik Current Transducer program. It is the first
More informationTRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:
Extract from the online catalog TRIO-PS/1AC/24DC/ 5 Order No.: 2866310 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 5 A Commercial data EAN 4046356046640 Pack 1 pcs. Customs
More informationISOMETER IRDH575. Approvals
Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with control and display function for EDS insulation fault location systems IRDH575_D00089_02_D_XXEN/09.2018 Insulation
More informationMEDIUM-VOLTAGE MEASURING VOLTAGE TRANSFORMERS USER MANUAL
MEDIUM-VOLTAGE MEASURING VOLTAGE TRANSFORMERS USER MANUAL F.T.M. S. r. l. Fabbrica trasformatori di misura Via Po, 3 20090 Opera MI - Italy Tel : +39 (0)2 576814 Fax : +39 (0)2 57605296 E-mail: info@ftmsrl.it
More informationFor non-electrical quantities
Controlgear 3UG3 monitoring relays 3RS17 interface converters N nsb0346h nsb0348h nsb0775h For electrical quantities For non-electrical quantities 3RS17 interface converter Selection and ordering data
More information24V dc Analog Block I/O Module
24V dc Analog Module Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through the block module. Refer
More informationModel SR554 Transformer Preamplifier
Model SR554 Transformer Preamplifier Model SR554 Transformer Preamplifier 1290-D Reamwood Avenue Sunnyvale, California 94089 Phone: (408) 744-9040 Fax: (408) 744-9049 email: info@thinksrs.com www.thinksrs.com
More informationABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault
More informationDEIF A/S. Description of options. Option H1 Serial communication CAN open. Description of options. Functional description. Tables.
Description of options Option H1 Serial communication CAN open 4189340277G SW version 2.42.X Description of options Functional description DEIF A/S Tables Parameter list Object dictionary DEIF A/S, Frisenborgvej
More informationPole Mount Installation Manual
Pole Mount Installation Manual Thank You for Choosing AIMS Power! 1. AIMS Power is a leading supplier of solar products, specializing in PV mounting systems. We ensure our products are manufactured to
More informationElectronically controlled proportional pressure regulating valves
Overview Description airfit control Electronically valve G1/4, G3/8, Type SRE-.. airfit control Electronically valve G3/8, G1/2, Type CRE-.. airfit control Electronically valve G3/4, G1, Type A25RE-..
More informationThree-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
More informationThree-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81
Data sheet Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 The three-phase monitoring relays CM-PVS.x1 monitor the phase parameters phase sequence, phase failure as well as over-
More informationElectronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.23 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.
More informationDifferential Charge Amplifier
Electronics Differential Type 58A... The differential charge amplifier is used for signal conversion of piezoelectric sensors with differential output. Executions Aluminum die-cast enclosure (IP64) Plastic
More informationABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable
More informationMINI MCR-SL-UI-f(-SP)
Configurable Analog Frequency Transducer INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The configurable analog frequency transducer MINI MCR-SL-UI-f(-SP) is used to convert analog standard
More information