Primary winding current transformer, type WSK

Size: px
Start display at page:

Download "Primary winding current transformer, type WSK"

Transcription

1 Technical documentation winding transformer, type DEIF /S Frisenborgvej 33 DK-7800 Sive Tel.: Fax: Document no.: D

2 Current transformers overview Clic on a product name or chec mar to jump to information page. Page Page nominal 30* 40* 40 N* N 31.5 nominal conductor in mm Round conductor in mm Transform. width in mm * For the transformers above, clic-on mountings are available for fitment onto 35mm DIN-rails (DIN 50022). conductor in mm Round conductor in mm Transform. width in mm 2

3 winding transformer Based on the physical operating principle of transformers, the required core volume transferring an amount of power, increases rapidly with a decreasing nominal. s there are limits on increasing the transformer size, winding transformer are being used. Interim transformers also belong to the group of winding transformer. This construction is mainly used for primary s of up to 10, and achieves a transformation at a higher or lower secondary values. In addition to their application in adapting a measuring circuit on existing measuring units, interim transformers are being used also for lowering the power loss by the transmission of analogically measured values over great distances. This is made possible by means of a squared dependence of the power loss from the flowing. PV = I 2 Z[V] apparent power [V] This means when the original nominal is halved, the conductor loss drops down to 25% of its original value. Indication: The selection of the nominal power of the initially activated main transformer is achieved through the application of the following measurement comparisions. 2 I P GH = P Z ( 2 ) I 1 + P E + P HZ P GH P Z P E P HZ I 1 I 2 apparent power of the main transformer secondary performance of the interim transformer (nominal performance inclusive of conductor losses) consumption of the interim transformer by nominal conductor losses between main- and interim transformer by nominal primary nominal of the interim transformer secondary nominal of the interim transformer 3

4 winding transformer 30 Secondary ccuracy class ccuracy class V rt.-no. rt.-no. rt.-no. rt.-no (1.3 7 ) (1.1 8 ) (1.8 5 ) (2.4 4 ) (2.4 0 ) l (3.0 9 ) (2.9 7 ) - P 1 M a d e in G erm any x x x x x x x xxx xxx (2.3 6 ) g ( lbs) DIN rail mounting Item number: Sealed shutter Type:

5 winding transformer 40 Secondary (1.7 7 ) (1.5 7 ) (2.2 4 ) (2.8 3 ) ccuracy class ccuracy class V rt.-no. rt.-no. rt.-no. rt.-no (2.7 9 ) l (3.4 8 ) (3.3 6 ) - P 1 M a d e in G erm any x x x x x x x xxx xxx (1.9 7 ) (2.7 5 ) g ( lbs) DIN rail mounting Item number: Sealed shutter Type:

6 winding transformer 40 N Secondary ccuracy class ccuracy class V rt.-no. rt.-no. rt.-no. rt.-no (2.1 6 ) (1.9 6 ) (2.6 7 ) (3.2 2 ) (2.7 7 ) l (4.3 3 ) (4.3 1 ) - P 1 M a d e in G erm any x x x x x x x xxx xxx (1.9 6 ) (2.7 5 ) g ( lbs) DIN rail mounting Item number: Sealed shutter Type:

7 winding transformer 60 Secondary (1.7 7 ) ccuracy class ccuracy class V rt.-no. rt.-no. rt.-no. rt.-no (2.3 6 ) (3.0 3 ) (3.6 2 ) (2.7 9 ) L (1.9 7 ) (2.7 5 ) g ( lbs) DIN rail mounting Not available Sealed shutter Type:

8 winding transformer 70.6 N Secondary (1.7 7 ) (2.3 6 ) (3.0 3 ) (3.6 2 ) (2.7 9 ) ccuracy class ccuracy class V rt.-no. rt.-no. rt.-no. rt.-no. V e d M 8 x 2 5 m m M 1 0 x3 0 m m (3.4 8 ) (3.3 6 ) L L (1.3 7 ) (1.9 6 ) (2.7 5 ) (3.3 8 ) (4.5 6 ) (5.3 5 ) g ( lbs) DIN rail mounting Not available Sealed shutter Type:

9 winding transformer 31.5 Secondary (1.6 9 ) L -H 2 -P (1.9 6 ) (2.7 6 ) (2.5 2 ) ccuracy class ccuracy class V rt.-no. rt.-no. rt.-no. rt.-no L (1.2 2 ) (3.9 3 ) (2.0 4 ) (2.5 5 ) (3.6 2 ) (4.5 2 ) g ( lbs) DIN rail mounting Not available Sealed shutter Type:

10 Current transformers ccessories for DCT Test certificate On request, we can provide you with a test certificate for a specific transformer along with the CT. Please inform us when placing your order. Sealed shutter On request, we can supply a transparent plastic cover. The cover seals the connections on the CT in a way that leaves the type label visible. Please chec availability on each individual data sheet. Excitation curve On request, we can provide you with an excitation curve for a specific transformer along with the CT. Please inform us when placing your order. Optional frequency Frequency range for a standard CT is 50-60Hz. On request, we can provide you with a frequency range from 16 2/3 400Hz. Please inform us when placing your order. Cast resin Cast resin is standard for all CT s with a nominal >4,000. On request, all CT s with a nominal <4,000 can be produced with cast resin. Please inform us when placing your order. The min. and max. weight specification for each type refers to standard versions. The specification is different if cast resin is ordered for CT s <4,000. Mounting Foot angle for screw mounting and busbar mounting screws with isolating protection caps are supplied along with the CT. DIN-rail mounting for tubes, plug-ins and protection transformers is available on request for certain CT types. Please chec availability on each individual data sheet. 10

Summation current transformers, type KSU/SUSK

Summation current transformers, type KSU/SUSK Technical documentation Summation transformers, type KSU/SUSK DEIF /S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4921210113E Data sheet

More information

DATA SHEET Selectable AC transducer TAS-311DG

DATA SHEET Selectable AC transducer TAS-311DG DATA SHEET Selectable AC transducer Measuring on AC networks Class 0.5 (IEC688) measurement Supply/measur. voltage up to 690 V Easy configuration via PC interface possible DEIF A/S Frisenborgvej 33 DK-7800

More information

DATA SHEET AC current single function transducer TAC-311DG/TAC-321DG

DATA SHEET AC current single function transducer TAC-311DG/TAC-321DG DATA SHEET AC current single function transducer TAC-311DG/TAC-321DG Compact design, 55 x 75 mm Easily accessible terminals Accuracy class 0.5 35 mm DIN rail or base mounting DEIF A/S Frisenborgvej 33

More information

DATA SHEET Reverse power relays, RMP-121D ANSI code 32

DATA SHEET Reverse power relays, RMP-121D ANSI code 32 DATA SHEET Reverse power relays, RMP-121D ANSI code 32 Protection against "motoring" Single phase measurement LED indication of fault condition Timer-controlled tripping LED indication for activated relay

More information

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions Installation and start up instructions TAS-311DG Selectable AC transducer Voltage, current, frequency or phase angle transducer Supply voltage up to 690V DEIF A/S Configuration via PC-interface possible

More information

DATA SHEET Differential current relays, RMC-131D ANSI code 87

DATA SHEET Differential current relays, RMC-131D ANSI code 87 DATA SHEET Differential current relays, RMC-131D ANSI code 87 Measurement of 3-phase currents Non-stabilised measurement Timer-controlled tripping Extra change-over relay contact for signalling DEIF A/S

More information

RMV-122D, RMV-132D ANSI

RMV-122D, RMV-132D ANSI DATA SHEET Voltage relays, RMV-112D, RMV-122D, RMV-132D ANSI codes 27/59, 59, 27 Under-voltage/over-voltage 3-phase measurement LED indication of fault condition Timer-controlled tripping LED indication

More information

Installation and start up instructions. Synchroniser type FAS-115DG uni-line H (UK) Synchronisation of generator to busbar

Installation and start up instructions. Synchroniser type FAS-115DG uni-line H (UK) Synchronisation of generator to busbar Installation and start up instructions Synchroniser type FAS-115DG uni-line Synchronisation of generator to busbar With voltage matching Circuit breaker time compensation LED indication of status DEIF

More information

Protection relays and controllers. Types TRANSAL DC-2TF, ACV-3TF, ACI-3TF, PFC-2TF TRANSAL DC-2TB, AVC- 3TB, ACI-3TB, PFC-2TB

Protection relays and controllers. Types TRANSAL DC-2TF, ACV-3TF, ACI-3TF, PFC-2TF TRANSAL DC-2TB, AVC- 3TB, ACI-3TB, PFC-2TB Protection relays and controllers Types TRANSAL DC-2TF, ACV-3TF, ACI-3TF, PFC-2TF TRANSAL DC-2TB, AVC- 3TB, ACI-3TB, PFC-2TB 4921250026C Transal TF Transal TB DEIF A/S Available for the following inputs:

More information

Installation and start up instructions. Paralleling relay type HAS-111DG uni-line G (UK) Synchronisation of generator to busbar

Installation and start up instructions. Paralleling relay type HAS-111DG uni-line G (UK) Synchronisation of generator to busbar Installation and start up instructions Paralleling relay type HAS-111DG uni-line 4189340146G (UK) Synchronisation of generator to busbar Setting of phase angle difference Setting of frequency and voltage

More information

Installation and start up instructions. Synchroniser type FAS-113DG uni-line F (UK) Synchronisation of generator to busbar

Installation and start up instructions. Synchroniser type FAS-113DG uni-line F (UK) Synchronisation of generator to busbar Installation and start up instructions Synchroniser type FAS-113DG uni-line Synchronisation of generator to busbar Circuit breaker time compensation LED indication of status LED indication for activated

More information

Transducers for AC measurement. Types TAP, TAQ, TMF, TAA, TAV, TAC. Measurement of: watt, var, frequency, phase angle, voltage, current

Transducers for AC measurement. Types TAP, TAQ, TMF, TAA, TAV, TAC. Measurement of: watt, var, frequency, phase angle, voltage, current Transducers for AC measurement Types TAP, TAQ, TMF, TAA, TAV, TAC 4921220002E Measurement of: watt, var, frequency, phase angle, voltage, current DEIF A/S Accuracy class 0.5 For mounting on DIN rail Compact

More information

DATA SHEET. Paralleling relays, HAS-111DG ANSI code 25

DATA SHEET. Paralleling relays, HAS-111DG ANSI code 25 DATA SHEET Paralleling relays, ANSI code 25 Synchronisation of generator to busbar Setting of phase angle difference Setting of frequency and diff. LED indication of status LED for synchronising signal

More information

DATA SHEET. CIO multi-inputs. CAN bus-based I/O module

DATA SHEET. CIO multi-inputs. CAN bus-based I/O module DATA SHEET CAN bus-based I/O module 8 multi-functional inputs Selectable as: o Digital input, 0(4) to 20 ma, 0 to 10 V, RMI, Pt100, Pt1000, Thermocouple type E, J, K, N, R, S or T Wire break detection

More information

DEIF A/S. User s manual. Read synchroscope type RSQ-3. Precision LED synchronoscope. High immunity to harmonic distortion F (UK)

DEIF A/S. User s manual. Read synchroscope type RSQ-3. Precision LED synchronoscope. High immunity to harmonic distortion F (UK) User s manual Read synchroscope type RSQ-3 4189340264F (UK) Precision LED synchronoscope High immunity to harmonic distortion DEIF A/S DEIF A/S Tel.: (+45) 9614 9614 Frisenborgvej 33, DK-7800 Skive Fa:

More information

Automatic synchronising relay

Automatic synchronising relay Synchronising relays Types FAS-2N, FAS-3N, HAS-2N 4921250029D FAS-3N High accuracy (±3 el.) and fast synchronisation DEIF A/S Circuit breaker time compensation Test switch Voltage matching (type FAS-3N)

More information

DEIF A/S. Application note. Generators parallel with mains Multi-line 2 version 2. Application description. Power import control. Power export control

DEIF A/S. Application note. Generators parallel with mains Multi-line 2 version 2. Application description. Power import control. Power export control Generators parallel with mains Multi-line 2 version 2 4189340363B Application description Power import control DEIF A/S Power export control DEIF A/S, Frisenborgvej 33 Tel.: +45 9614 9614, Fax: +45 9614

More information

DATA SHEET. Voltmeters and Ammeters,

DATA SHEET. Voltmeters and Ammeters, DATA SHEET Voltmeters and Ammeters, Moving Coil (type ) Q48, Q72, Q96, Q144 90 or 240 pointer Accuracy class 1.5 Exchangeable scale (type x) Document no.: 4921210012S Application: Moving-coil instruments

More information

DATA SHEET. Switchboard instruments,

DATA SHEET. Switchboard instruments, DATA SHEET Switchboard instruments, types Standard DIN sizes Quadratic instruments: Q48 Q144 Edgewise instruments: 48 x 24 144 x 72 mm Slim edgewise instruments: 72 x 24 144 x 36 mm Accuracy class 1.5

More information

Function. Adjustment. Extra functions included. Modes. Housing

Function. Adjustment. Extra functions included. Modes. Housing Electronic Electronic potentiometer potentiometer DATA DATA SHEET SHEET Function Replaces normal motor potentiometers Adjustment Integrating time (like variable gearboxes) Output start value Output end

More information

DEIF A/S. Application Notes. MDR-2 test procedures. Test of current measurement. Test of differential current measurement.

DEIF A/S. Application Notes. MDR-2 test procedures. Test of current measurement. Test of differential current measurement. MDR-2 test procedures 4189340423A MDR-2 SW version 1.1 and later Test of current measurement Test of differential current measurement DEIF A/S Test of trip DEIF A/S, Frisenborgvej 33 Tel.: +45 9614 9614,

More information

MBS AG. KBR 18 Split-core current transformer. Further information about our new split-core current transformer KBR 18: Dimensions:

MBS AG. KBR 18 Split-core current transformer. Further information about our new split-core current transformer KBR 18: Dimensions: KBR 18 Split-core current transformer Dimensions: Round conductor: 18 mm Transformer width: 41.6 mm Transformer height: 64.5 mm Transformer depth incl. fixing clasps: 67.3 mm General technical specifications:

More information

Installation and start up instructions. Detection of vector shift. Detection of over- and underfrequency. Generator disconnection on mains failure

Installation and start up instructions. Detection of vector shift. Detection of over- and underfrequency. Generator disconnection on mains failure Installation and start up instructions G59 Relay Package uni-line 4189340236C (UK) Detection of df/dt (rate of change of frequency R.O.C.O.F.) Detection of vector shift Detection of over- and underfrequency

More information

Accessories. Accessories

Accessories. Accessories Accessories Accessories Voltage transformer Voltage transformer Powerful and precise Input, 3-pole Output is 3-pole + N Use in IT networks without neutral line For reducing the measurement voltage for

More information

MODEL AT-10 ANALOG TRANSMITTER

MODEL AT-10 ANALOG TRANSMITTER MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca

More information

Data Sheet. Summation Current Transformer. RISH SUMMATION CT : RISH XMER Sigma. RISH XMER Sigma. Page 1 of 5 00 / 1213

Data Sheet. Summation Current Transformer. RISH SUMMATION CT : RISH XMER Sigma. RISH XMER Sigma. Page 1 of 5 00 / 1213 RISH SUMMATION CT RISH XMER Sigma Data Sheet RISH XMER Sigma Summation Current Transformer Tel. +91 253 2202160, 2202202 Fax +91 253 2351064 E-mail India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in

More information

Current / residual current and voltage transformers. Current / residual current and voltage transformers

Current / residual current and voltage transformers. Current / residual current and voltage transformers Current / residual current and voltage transformers Current / residual current and voltage transformers 1 Overview Current transformer overview DIN rail current transformer with fuse Current transformer...

More information

DEIF A/S. Insulation monitor. Type SIM-Q

DEIF A/S. Insulation monitor. Type SIM-Q Insulation monitor 4921232C Monitoring of insulation resistance on ungrounded AC networks (IT network) Working voltage up to 69V AC, withstands up to V DC Measuring range 1...Mohm or 1...Mohm Alarm on

More information

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters CURRENT TRANSFORMERS Current Transformers Analogue Panel Meters Shunts Digital Multimeters

More information

TCM-2 Thyristor Control Module DATA SHEET

TCM-2 Thyristor Control Module DATA SHEET TCM-2 Thyristor Control Module TCM-2 Thyristor DATA DATA SHEET Control Module DATA SHEET Insulation monitors, Warning delay and power-up delay Indication of set point on front Measuring range up to 440

More information

Angle position transmitter Type RT-2 Marine bridge instrumentation C (UK) Measuring output: DC current signal 0..20mA or 4..

Angle position transmitter Type RT-2 Marine bridge instrumentation C (UK) Measuring output: DC current signal 0..20mA or 4.. Installation instructions Angle position transmitter Type RT-2 Marine bridge instrumentation DEIF A/S Analogue output for direct connection of one or more indicators Measuring output: DC current signal

More information

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section 2, Calibration Calculations... 7 Calibration Procedure... 8 Section

More information

DEIF A/S. Description of options. Option H3 Serial communication Profibus DP Multi-line 2 version 2. Description of option. Functional description

DEIF A/S. Description of options. Option H3 Serial communication Profibus DP Multi-line 2 version 2. Description of option. Functional description Description of options Option H3 Serial communication Profibus DP Multi-line 2 version 2 4189340279I SW 2.42.X Description of option Functional description DEIF A/S Parameter table Data tables DEIF A/S,

More information

Series P. Applications

Series P. Applications Ratings 25 800 VA Voltage Primary 230 / 400 / 460 V range Secondary 6 / 12 V 12 / 24 V 24 / 48 V 115 / 230 V Voltage selection by means of metal connection bridges, offering the full rated power at any

More information

Installation and Operating Manual

Installation and Operating Manual GB Analog Weight Transmitter PS-1000 Installation and Operating Manual LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section

More information

RISH Ducer E13 3 channel transducer for AC current and voltage

RISH Ducer E13 3 channel transducer for AC current and voltage RISH Ducer E13 3 channel transducer for C current and voltage The RISH Ducer E13 ( Fig. 1) converts 3 sine wave C current or C voltage into 3 output signals that can serve several receiving instruments

More information

Data Sheet. Summation Current Transformer OMEGA SUMMATION CT : SIGMA SERIES. Page 1 of 5 00 / 1213

Data Sheet. Summation Current Transformer OMEGA SUMMATION CT : SIGMA SERIES. Page 1 of 5 00 / 1213 OMEGA SUMMATION CT : SIGMA SERIES Data Sheet Summation Current Transformer Page 1 of 5 Omega Summation current transformers are designed to summarize several synchronous Alternating Currents of equal phase

More information

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X RA 29 934/0.98 Electronic amplifier for the control of proportional valves without position control Model T 3024, Series 3X RA 29 934/2.9 The amplifier T 3024-3X is suitable for the control of pilot operated

More information

No-wear isolation of potentials in terminal block design

No-wear isolation of potentials in terminal block design TERMOPTO Overview No-wear isolation of potentials in terminal block design Space saving solid-state relay with PUSH IN connection technology The TERMOPTO opto modules are characterised by a particularly

More information

Measuring current transformers of the W, W series

Measuring current transformers of the W, W series Measuring current transformers of the W, W -8000 series W(-8000)_D00078_01_D_XXEN/09.2015 Measuring current transformers of the W, W -8000 series Product description The highly sensitive W and W -8000

More information

Short-circuit-proof switching amplifier for inductive loads up to 10 A

Short-circuit-proof switching amplifier for inductive loads up to 10 A MICROOPTO Overview Short-circuit-proof switching amplifier for inductive loads up to 10 Powerful, compact solid-state relay with error signalling contact The MICROOPTO family offers the customer high-quality

More information

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output) MODEL EM4000ACF Multifunction Transducer for alternating voltage and current Power supply voltages: Suitable for DIN-rail mounting 85 240Vac 400,440Vac 24 65Vdc 100..330Vdc V, A, W, VA, var, Hz, V, Avg.

More information

General Specifications

General Specifications General Specifications GS J08X0-0E FX Series Computing Units (Variable/Fixed Software Type) Moving Average Unit, Dead Time Unit, Velocity Unit, First Order Lug Unit, First Order Lead Unit, Velocity Limiter,

More information

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2 Data Sheet 066.8e Transducers for Active and Reactive Power EW 2.2 DGW 2.2 VGW 2.2 DUW 2.2 VUW 2.2 Application The E/DG/VG/DU/VU W 2.2 power transducers convert all forms of active and reactive power polarity

More information

General Specifications

General Specifications General Specifications GS J0X02-01E WX2 Series Computing Units (Variable/Fixed Software Type) Moving Average Unit, Dead Time Unit, Velocity Unit, First Order Lug Unit, First Order Lead Unit, Velocity Limiter,

More information

Output of three-phase motors at 50 Hz and 400 V

Output of three-phase motors at 50 Hz and 400 V RT0, RH Coupling Relays (Interfaces) Description DC operation IEC 0 947 and EN 0 947 (VDE 00) The RT0 coupling relays for switching motors and RH for auxiliary circuits are laid out to the special requirements

More information

Instrument transformers for indoor applications. Product overview. Instrument transformers for indoor applications.

Instrument transformers for indoor applications. Product overview. Instrument transformers for indoor applications. Instrument transformers for indoor applications Product overview Instrument transformers for indoor applications Product overview 2 I N S T R U M E N T T R A N S F O R M E R S F O R I N D O O R A P P L

More information

MEDIUM VOLTAGE PRODUCT. TJP 6.1, TJP 6.2 Indoor voltage transformers

MEDIUM VOLTAGE PRODUCT. TJP 6.1, TJP 6.2 Indoor voltage transformers MEDIUM VOLTAGE PRODUCT TJP 6.1, TJP 6.2 Indoor voltage transformers 2 TJP 6.1, TJP 6.2 INDOOR VOLTAGE TRANSFORMERS Parameters Highest voltage for equipment Power frequency test voltage, 1 min. Lightning

More information

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A. 3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2 (Code 7 71 071 to 7 71 083) INSTRUCTION MANUAL ( M 981 200 / 00 A ) (c) CIRCUTOR S.A. ----- MKT- MKT2 - ELECTRONIC METERS -------- M-981 200 --- Page Nº 2 3

More information

DEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF

DEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF / LF Insulation monitor Monitoring of insulation resistance on ungrounded AC networks (IT network) Working voltage up to 69V AC, withstands up to V DC Measuring range...kω or 1...MΩ Working frequency down

More information

MEDIUM VOLTAGE PRODUCT. TJP 7.x Indoor voltage transformers

MEDIUM VOLTAGE PRODUCT. TJP 7.x Indoor voltage transformers MEDIUM VOLTGE PRODUCT TJP 7.x Indoor voltage transformers 2 TJP 7.X INDOOR VOLTGE TRNSFORMERS Parameters Highest voltage for equipment Power frequency test voltage, 1 min. Lightning impulse test voltage

More information

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4] MODEL: MMNV Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels

More information

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback RA 29 939/06.98 Electronic Amplifier Model T 301 and T 3018 (Series 3X) for the control of proportional directional valves, without positional feedback RA 29 939/06.98 Replaces: 09.94 Electronic amplifier

More information

ULTRASTAB IHF Precision Current Transducer

ULTRASTAB IHF Precision Current Transducer ULTRASTAB 867-200IHF Precision Current Transducer The Ultrastab 867-200IHF Current Transducer is a model in the Ultrastab Current Transducer program. It is the second generation of current transducers

More information

PRODUCT FOR HIGH VOLTAGE APPLICATION. Current transformers for Gasinsulated. Instructions for installation, use and maintenance

PRODUCT FOR HIGH VOLTAGE APPLICATION. Current transformers for Gasinsulated. Instructions for installation, use and maintenance PRODUCT FOR HIGH VOLTAGE APPLICATION Current transformers for Gasinsulated switchgear type ELK Instructions for installation, use and maintenance 2 CURRENT TRANSFORMERS FOR GAS-INSULATED SWITCHGEAR TYPE

More information

ULTRASTAB I U Precision

ULTRASTAB I U Precision ULTRASTAB 867-700I 867-700U Precision Current Transducer The Ultrastab 867-700I and 867-700U Current Transducers, are the latest models of the Ultrastab Current Transducers. They are the third generation

More information

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4] Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels CE marking

More information

Electronic timer CT-SDS.22

Electronic timer CT-SDS.22 CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication

More information

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket 41 Low profile PCB relays 8-12 - 16 41 1 & 2 Pole - Low profile (15.7 mm height) 41.31-1 Pole 12 (3.5 mm pin pitch) 41.52-2 Pole 8 (5 mm pin pitch) 41.61-1 Pole 16 (5 mm pin pitch) PCB mount - direct or

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS IMD Manager IMD 100 DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: 9614 9615 Info@deif.com www.deifwindpower.com 4189360018 Rev.: A Date: 2016-12-22 Language:

More information

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK PP, PP and PB ISO 900 C E R T Y F I K A T 4 mm SERVICE MANUAL Contents Page. APPLICATION... 2. BASIC REQUIREMENTS.... TRANSDUCER SET... 4 4. TECHNICAL

More information

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New) XP2-R Power and reverse power relay (January 2006) Manual XP2-R (Revision New) Woodward Manual XP2-R GB Woodward Governor Company reserves the right to update any portion of this publication at any time.

More information

W DATA SHEET Current Transformer 40 x 10, A

W DATA SHEET Current Transformer 40 x 10, A W DATA SHEET Current Transformer 40 x 10, 250 600A W SCHRACK-INFO Current transformers for low-voltage network accuracy Single-phase current transformer Passing cable/ bus bar primary Primary current 250

More information

General Specifications

General Specifications General Specifications GS J0X-0E Model MXT Universal Computing Unit (-input, Isolated -output Type) General This plug-in type universal computing unit receives DC current or DC voltage signals, applies

More information

AUTOMOTIVE CURRENT TRANSDUCER HAB 60-S/SP5

AUTOMOTIVE CURRENT TRANSDUCER HAB 60-S/SP5 AUOMOIVE CURREN RANSDUCER HAB 60-S/SP5 Introduction he HAB Family is best suited for DC, AC or pulsed currents measurement in high power and low voltage automotive applications. It s contains galvanic

More information

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Direct connection up to 65 A (WSx10x) Connection with current transformer (WSx30x) Industrial or meters

More information

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A

More information

Product Information Measuring resistor with the Pt100-sensor referring to DIN EN Pt100, Pt500, Pt1000

Product Information Measuring resistor with the Pt100-sensor referring to DIN EN Pt100, Pt500, Pt1000 Platinum sensor probe - Basic information The Pt100-sensor is used for precise temperature monitoring applications, where errors in measurement have to be excluded. The linear relationship of the resistor

More information

XP2-R Power and Reverse Power Relay

XP2-R Power and Reverse Power Relay XP2-R Power and Reverse Power Relay Manual XP2-R (Revision C) Woodward Manual XP2-RE Woodward reserves the right to update any portion of this publication at any time. Information provided by Woodward

More information

Option D1 Voltage/var/cos phi control Description of option Functional description

Option D1 Voltage/var/cos phi control Description of option Functional description MULTI-LINE 2 DESCRIPTION OF OPTIONS Option D1 Voltage/var/cos phi control Description of option DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com

More information

MEDIUM VOLTAGE PRODUCT. TJP 5.x Indoor voltage transformers

MEDIUM VOLTAGE PRODUCT. TJP 5.x Indoor voltage transformers MEDIUM VOLTAGE PRODUCT TJP 5.x Indoor voltage transformers 2 TJP 5.X INDOOR VOLTAGE TRANSFORMERS 01 Voltage transformer TJP 5.1 and TJP 5.2 with suitable fuses Parameters Highest voltage for equipment

More information

RING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS USER MANUAL

RING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS USER MANUAL RING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS F.T.M. S. r. l. Fabbrica trasformatori di misura Via Po, 3 20090 Opera MI - Italy Tel : +39 (0)2 576814 Fax : +39 (0)2 57605296 E-mail: info@ftmsrl.it

More information

Modular step relays 16 A

Modular step relays 16 A Automation for blinds, grilles and shutters Lighting control in corridors (for hotels, offices and hospitals) Bedroom light control Living room light control SЕRIES FINDER reserves the right to alter characteristics

More information

Operating Instruction

Operating Instruction Level and Pressure Operating Instruction VEGASEL 643 6 5 + + 3 5 + + max. min. on VEGASEL 643 5 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 1 Product description 1.1 Function

More information

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA

More information

DZD 92 L. Wiring diagram. Time domains. Function. Dimensional drawing. Indicators. Accessories

DZD 92 L. Wiring diagram. Time domains. Function. Dimensional drawing. Indicators. Accessories DZD 92 L Multi-Function - Multi-domain time relay Mono voltage 8 Functions Setting range 0.05 s to 100 h subdivided into 7 time domains 1 immediate-action and 1 time contact or 2 time contacts (adjustable)

More information

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and

More information

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas Mimablad: 176GB/1999-10-25 Ersätter: MG-1000-EEx USAGE MG-1000-EEx is suitable for use in measurement

More information

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X Electronic amplifier for the control of proportional valves without position control Model T 3006, Series 3X RA 29 926/06.98 Replaces: 02.96 The amplifier T 3006-3X is suitable for the control of pilot

More information

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description Universal current transducer Data sheet 104059_en_05 PHOENIX CONTACT 2011-03-09 1 Description MCR-SL-CUC-...-I and MCR-SL-CUC-...-U active current transducers convert DC, AC, and distorted currents into

More information

Medium-voltage transfomers

Medium-voltage transfomers Medium-voltage transfomers We make energy measurable and take care of your future www.mbs-ag.com Page 2 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com Contents Technical characteristics From page 4 Current

More information

Three-phase monitoring relays CM-PVS.81

Three-phase monitoring relays CM-PVS.81 Data sheet Three-phase monitoring relays CM-PVS.81 The three-phase monitoring relay CM-PVS.81 monitors the phase parameters phase sequence, phase failure as well as over- and undervoltage. The device is

More information

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and

More information

Feed back element in high performance gradient amplifiers Feed back element in precision current regulated power supplies

Feed back element in high performance gradient amplifiers Feed back element in precision current regulated power supplies ULTRASTAB 866 Precision Current Transducer The Ultrastab 866 Current Transducer is the most proven fluxgate transducer with onboar electronics in the Danfysik Current Transducer program. It is the first

More information

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.: Extract from the online catalog TRIO-PS/1AC/24DC/ 5 Order No.: 2866310 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 5 A Commercial data EAN 4046356046640 Pack 1 pcs. Customs

More information

ISOMETER IRDH575. Approvals

ISOMETER IRDH575. Approvals Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with control and display function for EDS insulation fault location systems IRDH575_D00089_02_D_XXEN/09.2018 Insulation

More information

MEDIUM-VOLTAGE MEASURING VOLTAGE TRANSFORMERS USER MANUAL

MEDIUM-VOLTAGE MEASURING VOLTAGE TRANSFORMERS USER MANUAL MEDIUM-VOLTAGE MEASURING VOLTAGE TRANSFORMERS USER MANUAL F.T.M. S. r. l. Fabbrica trasformatori di misura Via Po, 3 20090 Opera MI - Italy Tel : +39 (0)2 576814 Fax : +39 (0)2 57605296 E-mail: info@ftmsrl.it

More information

For non-electrical quantities

For non-electrical quantities Controlgear 3UG3 monitoring relays 3RS17 interface converters N nsb0346h nsb0348h nsb0775h For electrical quantities For non-electrical quantities 3RS17 interface converter Selection and ordering data

More information

24V dc Analog Block I/O Module

24V dc Analog Block I/O Module 24V dc Analog Module Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through the block module. Refer

More information

Model SR554 Transformer Preamplifier

Model SR554 Transformer Preamplifier Model SR554 Transformer Preamplifier Model SR554 Transformer Preamplifier 1290-D Reamwood Avenue Sunnyvale, California 94089 Phone: (408) 744-9040 Fax: (408) 744-9049 email: info@thinksrs.com www.thinksrs.com

More information

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks. 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault

More information

DEIF A/S. Description of options. Option H1 Serial communication CAN open. Description of options. Functional description. Tables.

DEIF A/S. Description of options. Option H1 Serial communication CAN open. Description of options. Functional description. Tables. Description of options Option H1 Serial communication CAN open 4189340277G SW version 2.42.X Description of options Functional description DEIF A/S Tables Parameter list Object dictionary DEIF A/S, Frisenborgvej

More information

Pole Mount Installation Manual

Pole Mount Installation Manual Pole Mount Installation Manual Thank You for Choosing AIMS Power! 1. AIMS Power is a leading supplier of solar products, specializing in PV mounting systems. We ensure our products are manufactured to

More information

Electronically controlled proportional pressure regulating valves

Electronically controlled proportional pressure regulating valves Overview Description airfit control Electronically valve G1/4, G3/8, Type SRE-.. airfit control Electronically valve G3/8, G1/2, Type CRE-.. airfit control Electronically valve G3/4, G1, Type A25RE-..

More information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.

More information

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 Data sheet Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 The three-phase monitoring relays CM-PVS.x1 monitor the phase parameters phase sequence, phase failure as well as over-

More information

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.23 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.

More information

Differential Charge Amplifier

Differential Charge Amplifier Electronics Differential Type 58A... The differential charge amplifier is used for signal conversion of piezoelectric sensors with differential output. Executions Aluminum die-cast enclosure (IP64) Plastic

More information

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable

More information

MINI MCR-SL-UI-f(-SP)

MINI MCR-SL-UI-f(-SP) Configurable Analog Frequency Transducer INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The configurable analog frequency transducer MINI MCR-SL-UI-f(-SP) is used to convert analog standard

More information