1 Current / residual current and voltage transformers Current / residual current and voltage transformers 1
2 Overview Current transformer overview DIN rail current transformer with fuse Current transformer... / 1 A Moulded case current transformer (feedthrough type)... / 5 A *1 35 / 1 A 64 / 1 A CT27-35 CT27-64 IPA 40 IPA A A A A615.3 Round conductor in mm Primary bus bar in mm x x x 20 Primary current in A x x x x x x 20 Details: Page x 12 2 x 30 x x 12 2 x 40 x x 15 2 x 50 x 10 = 1 A = 5 A *1 Other variants on request 2
3 Overview Split transformer... / 5 A Cable type split core current transformers (to be used with isolated cables) Split 100 Split 800 Split 1000 Split 2000 KUW 1 / 30 KUW 1 / 40 KUW 2 / 40 KUW 4 / 60 KUW 4.2 / x x x
4 Overview Summation current transformer overview Summation current transformer *1 for cable type split core current transformers STS20 STS30 STS40 STS50 STS60 STS21 STS31 STS41 STS51 STS61 Transformation ratio Primary in A 1 5 Details: Page Customerspecific Customerspecific Customerspecific Customerspecific Customerspecific Summation current transformer for moulded case feedthrough and split core current transformers IPS20 IPS30 IPS40 IPS21 IPS31 IPS41 Transformation ratio Primary in A 1 5 Details: Page Customerspecific Customerspecific Customerspecific = 1 A = 5 A *1 Other variants on request 4
5 Current transformers Current transformers 5
6 Moulded case current transformer Moulded case CT, class 1 and 0.5 / 5 A Increased reliability Both halves of the housing overlap rather than butting up against one another Break-proof plastic housing made from polyamide Non-combustible per UL 94 VO and self-extinguishing Protective caps for primary bus bar fastening screws Fixing screws pins for the primary rail can be insulated by means of protective caps, available as an option Safeguard to prevent accidental contact Secondary connections Feeding of the secondary connections to the connection terminals through the rectangular opening in the front and rear sides Secondary connection by means of cable lugs through the side slots Expanded secondary terminal covering In addition to the normal terminal covering, extra protective hoods are available Locking of the front and rear feed to the secondary terminals All dimensions provided in mm IPA40 IPA40.5 6A A A A
7 Moulded case current transformer General mechanical properties Nominal frequency Hz Insulation class E (other classes on request) Thermal rated short-term current Ith = 60 x IN/1s Rated surge current Idyn = 2.5 x Ith, min., however 100 ka Highest voltage for operating equipment Um = 0.72 kv Rated insulation level (test voltage) 3 kv / 1 min (per EN ) Over-current limit factor FS5 or FS10 Harmonics currents up to 50th harmonic Device overview, moulded case current transformer, class 1 / 5 A Secondary current* Primary Power in VA Primary conductor (bus bars) Round conductor in mm Width in mm Weight (kg) IPA x 10; 30 x 15; 25 x IPA x 10; 30 x 15; 25 x A x 15 ; 20 x A x 15; 20 x A x 15, 20 x A x 15; 20 x A x 15; 20 x A x 15; 20 x A x 15; 20 x A x 15; 20 x A x 12; 2 x 30 x A , x 12; 2 x 30 x A , x 12; 2 x 40 x A , x 12; 2 x 40 x A , x 15; 2 x 50 x A , x 15; 2 x 50 x A , x 15; 2 x 50 x A , x 15; 2 x 50 x Device overview, moulded case current transformer, class 0.5 / 5 A Secondary current* Primary Power in VA Primary conductor (bus bars) Round conductor in mm Width in mm Weight (kg) IPA x 10; 30 x 15; 25 x IPA x 10; 30 x 15; 25 x IPA x 15 ; 20 x IPA x 15; 20 x A x 15, 20 x A x 15; 20 x A x 15; 20 x A x 15; 20 x A x 15; 20 x A x 15; 20 x A x 12; 2 x 30 x A , x 12; 2 x 30 x A , x 12; 2 x 40 x A , x 15; 2 x 50 x A , x 15; 2 x 50 x A , x 15; 2 x 50 x A , x 15; 2 x 50 x Accessories Mounting clip for DIN rail EN , suitable for IPA40 style, 1 pair Mounting clip for DIN rail EN , suitable for 6A315.3, 7A412.3 and 8A512.3 style, 1 pair Mounting clip for DIN rail EN , suitable for IPA40.5 style, 1 pair * Secondary current transformer / 1 A as well as other types on request. 7
8 Summation current transformer Summation current transformer, class 1 and 0.5 for feedthrough and split core Potential-free measurement Summation of the secondary currents from multiple main CTs Thus measuring of multiple feeders by just one meter Standardised measurement signal available at the output Alongside the addition of the input currents, the total is also divided by the number of inputs Distinction for similar and dissimilar main transformers General mechanical properties Break-proof plastic housing made from ABS, IP40 Non-combustible per UL 94 VO, self-extinguishing Nickel-plated terminals with Plus-Minus screws Integrated electric shock protection, IP10 Nominal frequency Hz Insulation class E (other classes on request) Thermal rated short-term current Ith = 60 x IN/1s Rated surge current Idyn = 2.5 x IN Maximum operating voltage Um = 0.72 kv * 1 Rated insulation level (test voltage) 3 kv / 1 min* 1 Over-current limit factor FS5 or FS10 Summation current transformer, class 1 Primary current in A Secondary Power in VA Transformation ratio Dimensions in mm (H x W x D) Weight (kg) IPS :1 115 x 45 x IPS :1:1 115 x 45 x IPS :1:1:1 115 x 45 x IPS :1 115 x 45 x IPS :1:1 115 x 45 x IPS :1:1:1 115 x 45 x Summation current transformer, class 0.5 Primary current in A Secondary Power in VA Transformation ratio Dimensions in mm (H x W x D) Weight (kg) IPS :1 115 x 45 x IPS :1:1 115 x 45 x IPS :1:1:1 115 x 45 x * 1 Other voltages on request. 8
9 Summation current transformer Summation current transformer, class 1 for cable type split core current transformers No-compromise, individual measurement High measurement accuracy User friendly spring-clamp technology Designed for use with the series KUW split core CTs Summation current transformer, class 1 Primary current in A Secondary Power in VA Transformer ratio Dimensions in mm (H x W x D) Weight (kg) STS :1 80 x 30 x STS :1:1 80 x 30 x STS :1:1:1 80 x 55 x STS :1:1:1:1 80 x 55 x STS :1:1:1:1:1 80 x 55 x STS Customer-specific 80 x 30 x STS Customer-specific 80 x 30 x STS Customer-specific 80 x 55 x STS Customer-specific 80 x 55 x STS Customer-specific 80 x 55 x With dissimilar main CTs, the ratio of the largest to the smallest primary current should not be lager than 10:1. STS20 / STS30 / STS21 / STS31 STS40 / STS50 / STS60 / STS41 / STS51 / STS61 9
10 Cable split core current transformers Cable split core current transformers Innovative and reliable Particularly well suited to digital measurement devices Especially fast installation For applications with insulated cable up to 2 x 42 mm max. Transformation ratio of / 1 A or ,000 / 5 A Including color-coded secondary cables Additional fastening of the transformer with the two UV-resistant cable ties provided Especially suited for retrofitting, primary circuit must not be disconnected Ideal for use in very compact installation spaces Fig.: KUW4.2/60 KUW1/30 KUW1/40 KUW2/40 10
11 Cable split core current transformers Environmental conditions Position of installation Ambient temperature (KUW1/30, KUW1/40, KUW2/40) Ambient temperature (KUW4/60 and KUW4.2/60) Relative humidity Protection class Application conditions For indoor usage, only for insulated cables C C 5 85 % (no condensation) IP20 Standard IEC Thermal short time rated current 60 x In / 1 s Thermal continuous current 100 % Rated isolation level Rated frequency Insulation class Cable feed through window 0.72 / 3 / kv 50 / 60 Hz E (120 C) For conductors max. Ø 18 / 28 / 42 or 2 x 42 mm Secondary conductor / 1 A: 0.5 mm² / 5 A: 1.5 mm² KUW4/60 KUW4.2/60 11
12 Cable split core current transformers Series KUW1 for insulated cable up to max. 18 mm diameter Primary Secondary Power in VA (at the end of the wire) Class Cable length in m Diameter Primary conductor in mm Weight (kg) KUW1/ KUW1/ KUW1/ KUW1/ KUW1/ KUW1/ KUW1/ KUW1/ KUW1/ KUW1/ KUW1/ KUW1/ KUW1/ KUW1/ KUW1/ Series KUW2 for insulated cable max. 28 mm diameter Primary Secondary Power in VA (at the end of the wire) Class Cable length in m Diameter Primary conductor in mm Weight (kg) KUW2/ KUW2/ KUW2/ KUW2/ KUW2/ KUW2/ KUW2/ KUW2/ KUW2/ Series KUW4/60 for insulated cable max. 42 mm diameter Primary Secondary Power in VA (at the end of the wire) Class Cable length in m Diameter Primary conductor in mm Weight (kg) KUW4/ KUW4/ KUW4/ KUW4/ KUW4/ KUW4/ KUW4/ KUW4/ , KUW4/ KUW4/ KUW4/ KUW4/ KUW4/ KUW4/ KUW4/ , Series KUW4.2/60 for insulated cable up to max. 2 x 42 mm diameter Primary current in A Secondary Power in VA (at the end of the wire) Class Cable length in m Diameter Primary conductor in mm Weight (kg) KUW4.2/ x KUW4.2/ x KUW4.2/ x KUW4.2/ x KUW4.2/ x KUW4.2/ x KUW4.2/ x KUW4.2/ , x KUW4.2/ x KUW4.2/ x KUW4.2/ x KUW4.2/ x KUW4.2/ x KUW4.2/ x KUW4.2/ , x
13 Split core current transformer Split core / current transformer Main features Typically for retro-fitting on bus bars For bus bars: 2 x 60 x 10 mm 60 x 35 mm For cables: Max. diameter 35 mm Split core / current transformer Primary current in A Secondary Power in VA Class Dimensions in mm (H x W x D) Weight (kg) Split x 89 x Split x 89 x Split x 89 x Split x 89 x Split x 89 x Split x 89 x Split x 89 x Split x 89 x Split x 89 x Split x 89 x
14 Split core current transformer Split core / current transformer Main features Typically for retro-fitting on bus bars For bus bars: 2 x 80 x 10 mm 80 x 32 mm For cables: Max. diameter 32 mm Split core / current transformer Primary current in A Secondary Power in VA Class Dimensions in mm (H x W x D) Weight (kg) Split , x 106 x Split , x 106 x Split , x 106 x Split , x 106 x Split , x 106 x Split , x 106 x
15 DIN rail current transformer DIN rail current transformer with voltage tap and fuse Save time and space For precise current and voltage measurement Integrated current transformer and fuse protected voltage tap Prevention of connection errors Specially developed for energy measurement up to 64 A Transformation ratios 35/1 and 64/1 A With test mark from KEMA-KEUR General Maximum voltage Insulation voltage Rated current Max. current (16 mm²) 690 V, Uimp 6 kv 1890 V / 50 Hz 1 min 35 / 64 A 42 / 76 A Protection class E (max. 120 ) Protection class IP20 Ambient temperature C Housing PA, 30 % glass proportion Screw connection cross head DIN 7962-H2 Terminal Standard IEC Connection cross-section Voltage tap-off Short-circuit withstand capability Connection cross-section max. Fuse type Current transformers 1.5 mm² 16 mm² 70 ka to 400 V / 50 Hz 4 mm² Standard IEC Maximum short term current Insulation voltage 5 x 25 mm (with notification) Max. 2 A SIBA DIN x In 3 kv / 50 Hz 1 min DIN rail current transformer overview Transformation ratio Power in VA Class Dimensions in mm (H x W x D) Weight (kg) CT 35/1A 35/1 A x 32 x CT 64/1A 64/1 A x 32 x
16 Current transformers Current transformer CT27 Class 1 Compact innovation Compact current transformer Particularly well suited to digital measurement devices Current transformer per IEC Transformation ratios 35/1, 64/1 A, class 1 Primary conductor feed-through window for insulated cable up to Ø 7.5 mm For use on a 3-phase circuit breaker with phase spacing of 17.5 mm DIN rail mounting (35 mm) via rail clamps (optional) Plug-in type CTs (Lego concept) Environmental conditions Position of installation Indoor usage; only for insulated conductors Ambient temperature C Relative humidity 5 85 % (no condensation) Protection class IP20 Application conditions Standard IEC Thermal short time rated current 60 x In / 1 s Thermal continuous current 100 % Rated isolation level 0.72 / 3 / kv Rated frequency 50 / 60 Hz Insulation class E (120 C) Cable feed through window Ø 7.5 mm Secondary conductor (spring clamps) Wire cross section: mm²; rigid, flexible Current transformer CT27 Class 1 Primary current in A Secondary Power in VA (at the terminal) Max. diameter, primary conductor in mm Dimensions in mm (H x W x D) Weight (kg) CT x 27 x CT x 27 x Accessories Mounting clip For DIN rail EN , suitable for CT27-35 and CT x 41 x
17 Residual current transformer Residual current transformer 17
18 Differential current transformer Differential current transformer, class 1 Handy and compact Simple and economical installation, especially for retrofit Practical locking system: Separating of primary cable not required Available in various different sizes No interruption of operations Suitable for UMG 96RM-E, UMG 20CM and UMG 512 General Construction style Single conductor low voltage residual current transformer Housing material Polycarbonate, grey RAL 7035 Max. voltage for electrical equipment Um < = 0.72 kv Insulation test voltage 3 kv Ueff.; 50 Hz; 1 min Rated frequency 50 Hz Secondary connection Brass profile, nickel plated, max. 4.0 mm 2 Nominal ratio Ipn / Isn 10 / A Working frequency range Hz Secondary rated apparent power 0.05 VA Accuraccy class 1 Ambient temperature range C Max. temperature of the primary conductor 90 C Differential current transformer type A Transformation ratio Max. primary residual current in ma* 18 Dimensions in mm Weight (kg) A B C / C1 D E KBU 23D 600: / KBU 58D 600: / KBU 812D 600: / * When using the analogue inputs of the UMG 96RM-E
19 Feedthrough residual current transformer Feedthrough residual current transformer High power at all levels Residual current transformer Compact construction Designed to increase the sensitivity of residual current monitoring devices Capturing of very small currents Nano-crystalline core Low weight Suitable for UMG 96RM-E and UMG 512 A C B Front view Base plate General data Nominal voltage 600 V Frequency 50 / 60 Hz Zero phase (primary / secondary) 200 ma / ma Ambient temperature C Power-frequency Test voltage Secondary to ground : 2 kv / 1 min. Insulation resistance Secondary to ground: 100 MΩ at 500 V DC Precision class L Feedthrough residual current transformer type A Transformation ratio Max. primary residual current in ma* Rated load impedance Dimensions in mm (H x W x D) Weight (kg) Ø A B C JZ30N 127/1 3, Ω JZ50N 127/1 3, Ω JZ65N 127/1 3, Ω JZ80N 127/1 3, Ω JZ100N 127/1 3, Ω JZ120N 127/1 3, Ω JZ150N 127/1 3, Ω JZ200N 127/1 3, Ω * When using the analogue inputs of the UMG 96RM-E 19
20 Current transformers for operating and differential current for the measurement device UMG 20CM Current transformer, class 1, CT20 Precise and efficient Can be used with operational currents up to max. 63 A and for residual currents from 1 ma to 1,000 ma acc. type A Compact construction Ratio 700/1 Primary window can be used for insulated cable Ø 7.5 mm (max.) For use on a 3-phase circuit breaker with a phase spacing of 17.5 mm DIN rail mounting (35 mm) via rail clamps (optional) Special version for the monitoring device UMG 20CM Current transformer CT-20 Environmental conditions Position of installation Ambient temperature C Relative humidity Protection class Application conditions Indoor usage; only for insulated conductors 5 85 % (no condensation) IP20 Measuring accuracy 1 % Thermal short time rated current 60 x In / 1 s Thermal continuous current 100 % Rated isolation level Rated frequency Insulation class Cable feed through window Secondary conductor 0.72 / 3 / kv 50 / 60 Hz E (120 C) Ø 7.5 mm Wire cross section: mm² Rigid, flexible, spring type terminal Current transformer CT-20 operating or differential current transformer type A Operating or residual current CT type A Max. operating Residual current in ma Transformation ratio Max. diameter, primary conductor in mm Class Dimensions in mm (H x W x D) Weight (kg) CT (with burden) / x 27 x Accessories Mounting clip For DIN rail EN , suitable for type CT x 41 x Ready-made connection cable 1.5 m with burden (0,8 Ω) and spring type terminal adapter for operating current measurement
21 Current transformers for operating and differential current for the measurement device UMG 20CM Split-core current transformer SC-CT-20 Innovative and flexible Compact, divisible, split-core current transformer Separable current transformer up to max. 63 A especially for retrofitting Transformation ratio 3,000/1 Primary window can be used for insulated cable up to Ø 10 mm Special version for the UMG 20CM branch circuit monitoring device 32 mm 14,7 mm 32,3 mm 41,4 mm Environmental conditions Position of installation Ambient temperature C Protection class Application conditions Indoor usage; only for insulated conductors IP20 Measuring accuracy 1 % Thermal continuous current 100 % Insulation resistance Rated frequency Max. frequency Secondary conductor 100 MOhm 50 / 60 Hz Hz Wire cross section: 0.75 mm² Rigid, flexible Split-core current transformer SC-CT-20 Max. operating current (A) Transformation ratio Max. primary conductor diameter in mm Class Accuracy (%) Dimensions in mm (H x W x D) Weight (kg) SC-CT-20* 63 3,000/ x 32 x Individual accessory (load is included the scope of the SC-CT-20 delivery) Burden (3.9 Ω) for operating current monitoring with the SC-CT-20 with 1.5 m ready-made connection cable and spring type terminal adapter * Incl. ready-made connection cable; 1.5 m with burden and spring type terminal adapter for operating current measurement 21
22 Current transformers for operating and differential current for the measurement device UMG 20CM Split-core current transformer SC-CT-21 Micro-fine and high-precision Compact, divisible, split-core current transformer Suitable for residual current measurement ( ma) High measurement accuracy Simple installation thanks to clip technology UL and EN certified Specially designed for use with the UMG 20CM Black White I 160 ± 20 AWG#22 S2(l) Black S1(k) White Measuring accuracy 1 % Current measurement range A Max. continuous current 35 A DC resistance 33 Ohm ±10 % Insulation category CAT III Environmental conditions Position of installation Indoor usage Ambient temperature C Storage temperature C Relative humidity < 85 % (no condensation) Protection class IP20 Split-core current transformer SC-CT-21 Residual current (ma) Transformation ratio Max. primary conductor diameter in mm Class Accuracy (%) Dimensions in mm (H x W x D) Weight (kg) SC-CT , / x 35 x
23 ON - Operating Current Mode OFF - RCM-Mode OC ON ON ON ON ON ON ON RCM OFF number of CT Current transformers for operating and differential current for the measurement device UMG 20CM 6-fold DIN rail current transformer CT-6-20 Monitor, detect and treat For operational current as well as RCM-monitoring suitable Residual current acquisition with integrated current transformers (residual currents per IEC type A) 6 measurement channels Compact construction Parallel acquisition and processing of measured values Use in distribution outputs for consumers and systems Special version for the monitoring device UMG 20CM 174,00 mm 21,00 Operating current and RCM fault sensor strip for UMG20CM CT T1 T2 T3 T2 T3 T5 T3 T2 T4 T4 T5 T4 T5 T6 Janitza electronics GmbH Vor dem Polstück 1 D Lahnau Deutschland X1 45,00 mm 56,00 mm Ratio: 1/700 Burden RCM/Operating Current: 0/1 Ohm Made in Germany Ib max: 63A Idiff max: 1000mA 21,00 General data Number of measuring channels Monitoring Evaluation Rated isolation level Transformer rated voltage Transformer rated frequency Therm. rated short-term current 6 (current transformers integrated) Parallel, real effective value measurement ("True RMS") Residual or operating currents (configurable as required in the individual application) 4 kv Therm. Continuous current 100% max. 720 V AC Hz 60 x In / 1 sec. Ambient temperature C Class 1 Protection class Protection class E IP20 6-fold DIN rail current transformer CT-6-20 (operating and residual current transformer type A) CT-6-20 Accessories Operating mode* 1 Residual or operating currents Operating current with load in A Residual current in ma Number of measuring channels* 2 Transformation ratio Measurement accuracy Max. primary conductor diameter in mm Dimensions in mm (H x W x D) Weight (kg) , / x 174 x Ready-made connection cable 1.5 m twisted, shielded with connector * 1 Pre-configurable as needed via DIP switch * 2 Measurement transformer integrated. 23
24 Current transformers for operating and differential current for the measurement device UMG 20CM Split core operating current CTs up to 600 A Fast installation reliable measurement Snap-in technology make installation in existing equipment easier Secure latching in place High number of secondary windings Small size, low weight Suitable for UMG 20CM D E C Ød A B k l SC-CT SC-CT SC-CT SC-CT SC-CT SC-CT Current ratio 120 A / 40 ma 200 A / 66,6 ma 300 A / 100 ma 400 A / 100 ma 500 A / 100 ma 600 A / 100 ma Current range (50/60 Hz) Position of installation Split core operating current transformer up to 600 A Operating mode Max. operating current in A SC-CT SC-CT SC-CT SC-CT SC-CT SC-CT , A (RL = 10 Ohm) 0, A (RL = 10 Ohm) Indoor usage (any mounting position) Transformation ratio Max. primary conductor diameter in mm Accuracy (%) Dimensions in mm (H x W x D) A B C D E Weight (kg) Operating current / ca measurement* 1 Operating current / ca measurement* 1 Operating current / ca measurement* 1 Operating current / ca measurement* 1 Operating current / ca measurement* 1 Operating current / ca measurement* 1 Single accessory (burden is included the scope of the transformer delivery) 0,1 300 A (RL = 10 Ohm) 0, A (RL = 5 Ohm) Ambient temperature C C Storage temperature C, rel. humidity <85 % (no condensation) Burden (2.2 Ω) for operating current transformer SC-CT with 1.5 m ready-made connection cable and spring type terminal adapter Burden (1.1 Ω) for operating current transformer SC-CT with 1.5 m ready-made connection cable and spring type terminal adapter Burden (0.8 Ω) for operating current transformer SC-CT /400/500/600 with 1.5 m ready-made connection cable and spring type terminal adapter * 1 Incl. ready-made connection cable; 1.5 m with burden and spring type terminal adapter for operating current measurement 0, A (RL = 5 Ohm) 0, A (RL = 5 Ohm) 24
Smart Energy & Power Quality Solutions THE JANITZA CURRENT TRANSFORMER RANGE
THE JANITZA CURRENT TRANSFORMER RANGE Smart Energy Smart Energy & Power & Quality Power Quality Solutions Solutions UMG 96 RM PN THE LINK BETWEEN HEAVY CURRENT AND MEASUREMENT TECHNOLOGY 2 The right current
More informationAccessories. Accessories
Accessories Accessories Voltage transformer Voltage transformer Powerful and precise Input, 3-pole Output is 3-pole + N Use in IT networks without neutral line For reducing the measurement voltage for
More informationMeasuring current transformers of the W, W series
Measuring current transformers of the W, W -8000 series W(-8000)_D00078_01_D_XXEN/09.2015 Measuring current transformers of the W, W -8000 series Product description The highly sensitive W and W -8000
More informationPowered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers
Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters CURRENT TRANSFORMERS Current Transformers Analogue Panel Meters Shunts Digital Multimeters
More informationSmart Energy & Power Quality Solutions. Portable energy measurement devices COMPACT FLEXIBLE PRECISE
Portable energy measurement devices COMPACT FLEXIBLE PRECISE Portable energy measurement devices COMPACT FLEXIBLE PRECISE The portable energy measurement devices from Janitza Stay flexible with the portable
More informationMeasuring current transformers of the W AB(P) series
Measuring current transformers of the W AB(P) series W-AB(P)_D00074_02_D_XXEN/07.2017 Measuring current transformers of the W AB(P) series Product description Measuring current transformers of the W -AB
More informationSmart Energy & Power Quality Solutions. Residual current monitoring (RCM) and energy data acquisition in a single device
Smart Energy & Power Quality Solutions Residual current monitoring (RCM) and energy data acquisition in a single device The RCM system solution RCM Modbus GridVis Analysis software Harmonics Alarm management
More informationMRG 96RM-E Flex RCM Mobile universal measurement device Supplementary description to the operation manual UMG 96RM-E
Doc. no. 2.040.127.0.b Subject to technical changes. www.janitza.com Mobile universal measurement device MRG 96RM-E Flex RCM Supplementary description to the operation manual UMG 96RM-E Janitza electronics
More informationW DATA SHEET Current Transformer 40 x 10, A
W DATA SHEET Current Transformer 40 x 10, 250 600A W SCHRACK-INFO Current transformers for low-voltage network accuracy Single-phase current transformer Passing cable/ bus bar primary Primary current 250
More informationElectronic Circuit Breaker with reset input ESS20-1..
Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and
More informationMRG 512-PRO PQ Flex Mobile universal measurement device Supplementary description to the operation manual UMG 512-PRO
Doc. no. 2.054.018.2 Subject to technical changes. www.janitza.com Mobile universal measurement device MRG 512-PRO PQ Flex Supplementary description to the operation manual UMG 512-PRO Janitza electronics
More information10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units
BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells
More informationMedium-voltage transfomers
Medium-voltage transfomers We make energy measurable and take care of your future www.mbs-ag.com Page 2 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com Contents Technical characteristics From page 4 Current
More informationRCMS460 and RCMS490 Series
4 T M RCMS460 and RCMS490 Series Digital Multi-Channel Ground Fault Monitor / Ground Fault Relay Grounded and High-Resistance Grounded AC/DC Systems Technical Bulletin NAE1042060 / 04.2013 BENDER Inc.
More informationN. TEST TEST DESCRIPTION
Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers Primary injection testing capabilities
More informationEMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004
Current Monitoring Relay Data Sheet 08/2004 Functions Structure Current monitoring of direct and alternating current in 1-phase networks with settable threshold values, starting override and response delay
More informationT-Line, current transformers
Type HF, primary current up to 5000 amps, accuracy classes from 0.2S to 3, highest system voltage 720 volt T-Line, current transformers Catalogue 208 . Table for contents...2 2. Description Current transformers
More informationMBS AG. KBR 18 Split-core current transformer. Further information about our new split-core current transformer KBR 18: Dimensions:
KBR 18 Split-core current transformer Dimensions: Round conductor: 18 mm Transformer width: 41.6 mm Transformer height: 64.5 mm Transformer depth incl. fixing clasps: 67.3 mm General technical specifications:
More informationSmart Energy & Power Quality Solutions. Power Quality Analyser UMG 512-PRO. Data sheet
Smart Energy & Power Quality Solutions Power Quality Analyser Data sheet Dok.-Nr. 2.054.030.0 02/2019 DEVICE VIEWS Front view Rear view Side view Bottom view Cut-out size: 92 +0,8 mm x 92 +0,8 mm. All
More informationIsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.
ProLine Interface Technology Loop-Powered Isolators for Standard Signals For isolation of 0(4)... 20 ma standard current signals on up to 3 channels. The Task If no power supply is available, the galvanic
More informationN. TEST TEST DESCRIPTION
Multi function system for testing substation equipment such as: current, voltage and power transformers, over-current protection relays, energy meters and transducers Primary injection testing capabilities
More informationInstallation / Monitoring Technique
Installation / Monitoring Technique VARIMETER RCM Residual Current Monitor, Type B for AC and DC Systems IP 5883 0249633 IP 5883 ND 5018/035 ND 5018/030 According to IEC/EN 62 020, VDE 0663 For AC and
More informationDipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 06401 807-0 Fax: 06401 807-259 Insulation fault locator Insulation fault locator for DC IT systems with high system leakage capacitances
More informationSeries P. Applications
Ratings 25 800 VA Voltage Primary 230 / 400 / 460 V range Secondary 6 / 12 V 12 / 24 V 24 / 48 V 115 / 230 V Voltage selection by means of metal connection bridges, offering the full rated power at any
More informationSINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator
SINEAX TI 807 without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically
More informationPHASED OUT. LED Driver Linear / area fixed output. Driver LCI 35W 350mA 900mA TOP lp TOP series
Product description Fixed output built-in LED Driver Constant current LED Driver Output current settable 350 900 ma Max. output power 35 W Nominal life-time up to 100,000 h For luminaires of protection
More informationOPTITEMP TT 20 Technical Datasheet
OPTITEMP TT 20 Technical Datasheet Analog PC-programmable two-wire transmitters for Pt100 Efficient PC-configuration without recalibration Very stable output Very fast response time The documentation is
More informationPHASED OUT. LED Driver Linear / area fixed output. Driver LCI 20W 150mA 400mA TOP lp TOP series. Product description
Product description EL Fixed output built-in LED Driver Constant current LED Driver Output current settable 150 400 ma Max. output power 20 W Nominal life-time up to 100,000 h For luminaires of protection
More informationElectronic Circuit Breaker ESS20-0..
Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,
More informationSINEAX TI 807 Passive DC signal isolator
without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically insulate
More informationQFM21... Duct sensors. Symaro. for relative humidity and temperature
1 864 1864P01 Symaro Duct sensors for relative humidity and temperature QFM21... Operating voltage AC 24 V / DC 13.5...35 V Signal output DC 0...10 V / 4 20 ma for relative humidity Signal output DC 0...10
More informationMINI-PS AC/24DC/1.3
Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics
More informationTheta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.
Technical Data Sheet Theta 60R 60 R 60 R Fig. Theta R, channel version, in housing S7 clipped on to a top - hat rail. Fig. Theta R, channel version, in housing S7 hole mounting brackets pulled out. Theta
More informationData Sheet. Summation Current Transformer OMEGA SUMMATION CT : SIGMA SERIES. Page 1 of 5 00 / 1213
OMEGA SUMMATION CT : SIGMA SERIES Data Sheet Summation Current Transformer Page 1 of 5 Omega Summation current transformers are designed to summarize several synchronous Alternating Currents of equal phase
More informationEnhanced Quality with a Touch of Style
Rudolf Current Transformer Enhanced Quality with a Touch of Style Current Transformer Enhanced Quality with a Touch of Style New Products Rudolf launched our new encapsulated current transformer. Portraying
More informationFor ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.
Current Transducer IT 700-S ULTRASTAB I PM = 700 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)
More informationT/3000 T/3000. Substation Maintenance and Commissioning Test Equipment
T/3000 Substation Maintenance and Commissioning Test Equipment MULTI FUNCTION SYSTEM FOR TESTING SUBSTATION EQUIPMENT SUCH AS: CURRENT, VOLTAGE AND POWER TRANSFORMERS, ALL TYPE OF PROTECTION RELAYS, ENERGY
More informationUMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks
Threshold value monitoring Pulse outputs UMG 96L / UMG 96 Universal measurement device Measuring accuracy Energy: Class 2 Current.../1 A,.../5 A Voltage L - N: ± 1 % Networks TN-, TT-Networks 2 digital
More informationMETRAClip87 and 88 Clamp Multimeters
3-349-795-03 1/7.14 Current and frequency measurement via clamp meter: METRAClip87: 1500 A AC TRMS and 1500 A DC METRAClip88: 2000 A AC TRMS and 3000 A DC Multimeter functions via connector sockets: V
More informationUMG 96RM Basic Device
Smart Energy & Power Quality Solutions Power Analyser Basic Device Data sheet Dok.-Nr. 2.040.172.0 02/2019 DEVICE VIEWS Front view Rear view Side view Bottom view max. 6 96 91,5 104 91,5 97 42 Cut-out
More information400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)
MODEL EM4000ACF Multifunction Transducer for alternating voltage and current Power supply voltages: Suitable for DIN-rail mounting 85 240Vac 400,440Vac 24 65Vdc 100..330Vdc V, A, W, VA, var, Hz, V, Avg.
More informationTransformers, Power Supply Units and Socket Outlets
Transformers, Power Supply Units and Socket Outlets /2 Introduction /3 4AC3 bell transformers /4 4AC3 safety transformers /5 4AC2 power supply units /6 5TE6 REG socket outlets For further technical product
More informationISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances
ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances _D00108_00_D_XXEN/05.2015 ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances
More informationMINI-PS AC/2X15DC/1
MII-PS-100-240AC/2X15DC/1 Power supply unit ITERFACE Data sheet 100299_en_04 1 Description PHOEIX COTACT - 2010-10-20 Features MII POWER is the extremely slim power supply unit with constructional widths
More informationRE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC
Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal
More information27/04/2015
Modular Carril DIN 35 mm HIL Part number 84871120 Control of AC and DC currents Automatic recognition of AC/DC Measurement ranges from 2 ma to 10 A Choice between over and undercurrent True RMS measurement
More informationPRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID
RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A
More information2/2 Introduction. Unequipped Distribution Boards 2/5 8GK1 surface and flush-mounting distribution boards
Siemens AG 010 ALPHA 160 - DIN Wall-Mounted Distribution Boards / Introduction Distribution Boards with Built-In Distribution Board Panels /4 8GK1 surface and flush-mounting with quickassembly kits Unequipped
More informationFor ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.
Current Transducer IT 700-SB ULTRASTAB I PM = 700 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features ± 10 V voltage output
More informationLED Driver Compact fixed output
w LED Driver Driver LCI 100W 900mA 1750mA TOP C TOP series Product description Fixed output built-in LED Driver Constant current LED Driver Output current settable 900 1,750 ma Max. output power 100 W
More informationSINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar
For electrically insulating, amplifying and converting DC signals 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1 and 2) is to electrically insulate input and output
More informationDRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE
87045 LIMOGES Cedex France Tel: (+33) 05 55 06 87 87 Fax: (+33) 05 55 06 88 88 DRIVIA cabinets CONTENTS NTS PAGES 1. Description, use....1 2. Range, equivalence table...1 3. Dimensions...1 4. General characteristics...2
More informationRI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters
RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA
More informationMeasuring current transformers of the W B series
Measuring current transformers of the W B series W-B_D00075_01_D_XXEN/09.2015 Measuring current transformers of the W B series Product description Measuring current transformers of the W B series are highly
More informationLED Driver Compact fixed output. Udriver LC 25/30/35/40W 600/700/800/900mA fixc SC ADV ADVANCED series
Udriver LC 5/3/35/4W 6/7/8/9mA fixc SC ADV ADVANCED series Product description Fixed output LED Driver Can be either used build-in or independent with clip-on strain-relief (see accessory) Constant current
More informationVEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage
More information08/07/2015
17.5 mm - 1 Solid State Relay 0.7A MUS2 Part number 88827004 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external
More informationPHASED OUT. LED Driver Compact fixed output. Driver LCI 20W 350mA 900mA TOP C TOP series
EL Product description Fixed output built-in LED Driver Constant current LED Driver Output current settable 30 900 ma Max. output power 20 W Nominal life-time up to 100,000 h For luminaires of protection
More informationSINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar
SINEAX TV 808, channels For electrically insulating, amplifying and converting DC signals Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. ) is to electrically insulate input and
More informationCustomer Premise. Solutions for. Solutions for Customer Premise include products ranging from wall distribution to system distribution boxes.
Solutions for Customer Premise Solutions for Customer Premise include products ranging from wall distribution to system distribution boxes. The product range of distribution boxes offers small distribution
More informationV2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...
P AC/DC current monitoring Multifunction Supply voltage 24-240V DC or 110-240V AC 1 change-over contact Width 22,5 mm Control element Tripping delay Maximum threshold Minimum threshold Function selector
More informationPHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 150mA 400mA TOP C TOP series. Product description
Product description EL Fixed output built-in LED Driver Constant current LED Driver Output current settable 15 4 ma Max. output power W Nominal life-time up to, h For luminaires of protection class I and
More informationSafety switches with slotted hole lever
Safety switches with slotted hole lever Selection diagram C1 C C C4 C5 Straight slotted hole lever Slotted hole lever at the left Slotted hole lever at the right (without bend) Slotted hole lever at the
More informationDUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER
OPERATOR S MANUAL DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Web Site: www..com
More informationRE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC
Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Complementary Contacts material Control type [Us] rated supply voltage Voltage range Main Range of product Product or component
More informationXR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)
XR1 Rotor Earth Fault Relay (May 2007) Manual XR1 (Revision New) Woodward Manual XR1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided
More informationUMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.
Harmonics GridVis Analysis software Modbus interface Measurement accuracy 0.5 Universal measurement device for DIN rails Communication Protocols: Modbus RTU / Slave Interface RS485 Power quality Harmonics
More informationRelays and associated toroids
Relays and associated toroids Residual-current protection relay Multi 9 format (DIN rail mount) E92034 E92035 E92036 RH10M. RH21M. RH99M. Multi 9 format (with mounting accessories (1) ) E90249 E90251 E90253
More informationTRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:
Extract from the online catalog TRIO-PS/1AC/24DC/ 5 Order No.: 2866310 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 5 A Commercial data EAN 4046356046640 Pack 1 pcs. Customs
More informationElectronic Thermostat TE-1 Version according to EN
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 3639 Fulda, Germany Postal address: 3635 Fulda, Germany Phone: +49 661 63- Fax: +49 661 63-67 e-mail: mail@jumo.net Internet: www.jumo.net JUMO
More informationPower quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I
Memory 256 MB Alarm management Residual current measurement Homepage Ethernet-Modbus gateway BACnet (optional) UMG 96 RM-E Power analyser with Ethernet and RCM Communication Modbus (RTU, TCP, Gateway)
More informationSpecifications Approval Type M12 A-coded HARAX M12-L HARAX M12 L 5 poles shielded M12 Crimp General data Electrical characteristics Materials 03 21
M12 A-coding Specifications IEC 60 352-4 Approval A-coding acc. to IEC 61 076-2-101 Circular Connectors Technical characteristics M12 A-coding Type M12 A-coded HARAX M12-L 5 poles HARAX M12 L shielded
More informationPHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 350mA 900mA TOP C TOP series
EL Product description Fixed output built-in LED Driver Constant current LED Driver Output current settable 35 9 ma Max. output power W Nominal life-time up to, h For luminaires of protection class I and
More informationRE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC
Characteristics off-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal
More informationContents. Han Hv ES / Han Hv E Technical characteristics Han Hv ES Technical characteristics Han Hv E Han 3 Hv ES
Contents S / Page Technical characteristics S............................. 04.10 Technical characteristics.............................. 04.11 3 S.............................................. 04.12 3...............................................
More informationSummation current transformers, type KSU/SUSK
Technical documentation Summation transformers, type KSU/SUSK DEIF /S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4921210113E Data sheet
More informationPower quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I
Harmonics Temperature input Measurement accuracy 0.5 Memory 4 MByte UMG 104 Energy measurement device for DIN rails Communication Profibus (DP / V0 optional) Modbus RTU Power quality Harmonics up to 40th
More informationLED Driver Compact fixed output
Driver C 5W 35-6mA flexc SC advanced series Product description Can be either used build-in or independent with clip-on strain-relief (see accessory) Constant current Adjustable output current between
More information08/07/2015
17.5 mm - 1 Relay 8A MUR1 Part number 88827105 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external load connection
More informationISOMETER IRDH575. Approvals
Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with control and display function for EDS insulation fault location systems IRDH575_D00089_02_D_XXEN/09.2018 Insulation
More informationLED Driver Compact fixed output
Driver C 6W -4mA flexc SC ADV ADVACED series Product description Can be either used build-in or independent with clip-on strain-relief (see accessory) Constant current ED Driver Adjustable output current
More informationVEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA
P Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationSmart Termination TECHNICAL SPECIFICATIONS CURRENT VOLTAGE INSTRUMENTRANSFORMER
Customer : REV. 0 Page 1/16 Smart Termination TECHNICAL SPECIFICATIONS CURRENT VOLTAGE INRUMENTRANSFORMER CVS - 24 - G - Revision Prepared Description Checked by Rev. Date by 0 13/06/16 First issue E.
More informationPHOENIX CONTACT
Selective circuit breaker CLIPLINE Data sheet 100464_en_05 PHOENIX CONTACT 2009-11-17 1 Description The electronic circuit breaker, which has a design width of just 12.5 mm, selectively protects all 24
More informationVariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.
ProLine Interface Technology Transducers for High Voltage / Shunt Applications Compact high voltage transducers with VariPower broad-range power supply and genuine calibrated range selection. The Task
More informationDimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung
Dimension diagrams All dimensions in mm 73 mm 10 mm 35 mm 44 mm 90 mm 90 mm 107,5 mm 50 mm 76 mm 82 mm Front view Side view Typical connection An. In R32 RS485 Dig. I/O Versorgungsspannung Auxiliary Supply
More informationQUINT-PS/ 3AC/24DC/10
Primary-switched power supply with SFB technology, 3 AC, output current 10 A INTERFACE Data sheet 103131_en_01 1 Description PHOENIX CONTACT - 09/2009 Features QUINT POWER power supply units Maximum system
More informationTechnical features table for miniature circuit-breakers SH 200 Series
Technical features table for miniature circuit-breakers SH 00 Series Standards Poles Tripping characteristics I n A frequency f Hz insulation voltage U i acc. to IEC/EN 60664-1 V Overvoltage category Pollution
More informationMEDIUM VOLTAGE PRODUCT. PARAMETERS GUIDE How to specify the indoor instrument transformers correctly
MEDIUM VOLTAGE PRODUCT PARAMETERS GUIDE How to specify the indoor instrument transformers correctly The range of electric values in the power supply systems is very extensive. This is why it is necessary
More informationEMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.
Electronic monitoring relay for voltage monitoring in three-phase networks INTERFACE Data sheet 102110_en_03 1 Description PHOENIX CONTACT - 09/2009 Features Increasingly higher demands are being placed
More information02/11/2015
35 mm - 1 Relay 8A OUR3 Part number 88867103 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external
More informationHexa Multi Module 366HMM. Introduction. Design Specifications. Key Features
Hexa Multi Module Introduction The E-Plex 366HMM is a six channel DC power distribution module capable of handling loads of up to 15A per channel or 50A total. The six channels can be utilized as either
More informationElectronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile
More informationUNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description
Primary-switched power supply unit Data sheet 106261_en_02 PHOEIX COTACT 2015-05-13 1 Description The power supply makes a worldwide impression thanks to maximum energy efficiency. ow idling losses (o
More informationRE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC
Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay
More informationRE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC
Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay
More informationZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR
ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR The flexibility of the Zucchini MS range during planning and installation makes it ideal for frequently changing requirements in small to medium sized commercial
More informationPluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header
Pluggable PCB terminals and headers Pluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header System features plug in system is simple
More informationFor ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.
Current Transducer IT 605-S ULTRASTAB I PN = 600 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Wide operating temperature
More information