1 PD p Rotating Anode X-ray tube Assembly 0.3/0.8P32&0.6/1.2P32DK-85 GENERAL The Shimadzu 0.3/0.8P32DK-85 & 0.6/1.2P32DK-85, Rotating Anode X-ray tube assemblies are rated to 150kV and feature a 100mm (inch) target of Rhenium-tungsten faced Molybdenum with a target angle 12. Anode heat content is 280kJ {00kHU} and the maximum anode heat dissipation rate is 1600W {2250HU/s}. The anticrystalization agent is mixed in tungsten, protecting the surface of the anode from becoming rough and cracked, so that reduction of effective X-ray dose is minimized over a long time of use. The target disk coated with high heat emission material enables stable X-ray output. The 0.3/0.8P32DK-85 & 0.6/1.2P32DK-85 are designed for gastro-intestinal examination, high-speed serialography. Focal spot combination of 0.3mm/0.8mm (for over-table) or 0.6mm/1.2mm (for C-arm table Cvision & over-table) is available. CONFIGURATION The 0.3/0.8P32DK-85& 0.6/1.2P32DK-85, Rotating Anode X-ray tube assemblies are composed as follows. Model 0.3/0.8P32DK-85 (Nominal focal spot; 0.3/0.8mm) 0.6/1.2P32DK-85 (Nominal focal spot; 0.6/1.2mm) Supporter B-80 Fan F-3
2 0.3/0.8P32&0.6/1.2P32DK-85 SPECIFICATIONS 0.3/0.8P32DK /1.2P32DK-85 Nominal focal spot 0.3mm 0.8mm 0.6mm 1.2mm Nominal X-ray tube Fluorography 125kV voltage Radiography 150kV X-ray tube Max. heat content 1100kJ {1600kHU} assembly Max. continuous heat dissipation 70W {660HU/s} X-ray tube Max. anode heat content Max. anode heat dissipation rate Max. continuous heat dissipation 280kJ {00kHU} 1600W {2250HU/s} 300W {20HU/s} X-ray tube Max. Anode stationary 200W {280HU/s} 355W {500HU/s} 355W {500HU/s} 25W {600HU/s} Fluoroscopic load (10min.) Anode rotating 355W {500HU/s} 25W {600HU/s} 25W {600HU/s} 25W {600HU/s} Nominal anode input power (0.1sec, 180Hz) (0.1sec.) 11kW 5kW 38kW 92kW Max. filament voltage 7.V 1.3V 12.5V 18.V Max. filament current *1 5.0A 5.6A 5.6A 5.6A Material Rhenium-tungsten faced molybdenum Anode target Angle 12 Diameter Anode rotation *2 Equivalent filtration Leakage radiation X-ray radiation field 100mm (inch) Direction of anode rotation is counterclockwise as viewed from the cathode side, and R.P.M are as follows. 2700min. -1 at 50Hz 3200min. -1 at 60Hz 9700min. -1 at 180Hz Min. 1.5mm Al equivalent Leakage radiation in hour from the X-ray tube assembly and collimator Is less than 0.87mGy at a distance of 1 meter from the focal spot. However, leakage radiation in an hour from the collimator is less than 0.30mGy mm ( inch) at 1000mm (39.inch) SID Min. ambient temperature -10 Safety circuit Weight The thermal switch actuates to break the high voltage generating circuit when the temperature inside the tube housing reaches kg (9.5) (inclusive of supporter and fan) *1 Refers to the maximum value usable in tube current regulation, and its limit in constant use is less than.6a for focus of 0.3mm, less than 5.2A for focus of 0.8mm, and less than 5.2A for both of 0.6mm focus and 1.2mm focus. *2 Combination with the optional SA-0, SA-1, SA-2, SA-50 and SA-60, starter. 2
3 0.3/0.8P32&0.6/1.2P32DK-85 HEATING AND COOLING CHARTS X-ray Tube anode X-RAY TUBE ASSEMBLY X-ray Tube HEATING assembly AND COOLING CURVE 1600 X-ray tube assembly heat content (khu) W 70W 冷却 Cooling 300W Time (min) 3
4 0.3/0.8P32&0.6/1.2P32DK-85 RADIOGRAPHIC RATING CHARTS Three Phase - Full Wave 0.3mm Focal Spot, 180Hz 0.8mm Focal Spot, 180Hz 0.6mm Focal Spot, 180Hz 1.2mm Focal Spot, 180Hz
5 EMISSION CHARTS 0.3/0.8P32&0.6/1.2P32DK-85 The charts show the emission characteristic under three phase full wave operation. In the case of single phase full wave operation, ma values are decreased by approximately 30% for same filament current. 0.3mm Focal Spot 0.8mm Focal Spot 0.6mm Focal Spot 1.2mm Focal Spot Emission & Filament Characteristics 0.6P32DK , Emission & Filament Characteristics 1.2P32DK 125kV 100kV 80kV X-ray Tube Current (ma) Filament Voltage 150kV 125kV 100kV 80kV 60kV 0kV Filament Voltage (V) X-ray Tube Current (ma) Filament Voltage 150kV 60kV 0kV Filament Voltage (V) Filament Current (A) Filament Current (A)
6 0.3/0.8P32&0.6/1.2P32DK-85 HIGH SPEED SERIALOGRAPHIC RATING CHARTS N.B. The load per exposure must be less than 70% or 80% of the maximum rating given by the radiographic rating charts. Load per exposures (HU) = kv ma s ( ) or kv ma s 1.35 ( 6 pulse ) or kv ma s 1.1 ( 12 pulse or ) Load per exposures (J) = kv ma s 0.71 ( ) or kv ma s 0.96 ( 6 pulse ) or kv ma s ( 12 pulse or ) DIMENSIONS 25 (9.6) Max. 20 (0.8) 15.2 (5.7) Focal Track φ8 (3.3) φ107 (.2) φ136 (5.) φ6 (1.8) 1.5 (0.06) 103 (.1) 21 (0.8) 69 (2.7) 18 (0.7) X-ray Tube UNIT : mm (inch) 6
7 DIMENSIONS (cont.) 0.3/0.8P32&0.6/1.2P32DK (9.0) 131 (5.2) 8.5 (3.3) 6 (18.3) 20 (9.) 161 (6.3) 10 (5.5) -M6 12 deep P.C.D. 92 U Mount φ18 (7.2) φ158 (6.2) 52 (2.0) 92 (3.6) focal spot 57 ± 1 (2.2) 100 (3.9) Reference axis 18 (5.8) 15 (0.6) UNIT : mm (inch) X-ray Tube Assembly UNIT : mm (inch) Supporter and Fan 7
8 0.3/0.8P32&0.6/1.2P32DK-85 Remarks * Every value in this Product Date Sheet is a standard value, and it may vary a little from the actual at each site. * The appearances and specifications are subject to change for reasons of improvement without notice. * Certain configurations may not be available pending regulatory clearance. Contact your Shimadzu representative for information on specific configurations. SHIMADZU CORPORATION. International Marketing Division 3. Kanda-Nishikicho 1-chome, Chiyoda-ku, Tokyo , Japan Phone: 81(3) Fax: 81(3) Cable Add.: SHIMADZU TOKYO URL Shimadzu Corporation Medical Systems Group has been certified by TUV Rheinland as a manufacturer of medical equipment and systems in compliance with ISO9001: 2000 Quality Management Systems and EN ISO1385: 2000 Medical Equipment Quality Management Systems.
Product Information PI
Rotating Anode X-ray Tube Assembly Product Information PI ROTANODE E7252X E7252FX E7252GX High speed rotating anode X-ray tube assembly for high energy radiographic and cine-fluoroscopic operations. The
More informationProduct Information PI
Rotating Anode X-ray Tube Assembly Product Information PI ROTANODE E7869X High speed rotating anode X-ray tube assembly for high energy radiographic operations. For the purpose of general diagnostic X-ray
More informationProduct Information PI
Rotating Anode X-ray Tube Assembly Product Information PI ROTANODE The TOSHIBA XH-183 housing is developed for use in surgical C-arm application. It provides ease for use at a nominal patient table height.
More informationProduct Information PI
Rotating node X-ray Tube ssembly Product Information PI ROTNODE E7884X E7884FX E7884GX Rotating anode X-ray tube assembly for high energy radiographic operations. The heavy anode is constructed with specially
More informationRotating Anode X-Ray Tube Housing Assembly. General Data
Display Devices & Components Company TECHNICAL DATA ROTANODE TM E7252X Rotating Anode X-Ray Tube Housing Assembly! High speed rotating anode X-ray tube housing assembly for high energy radiographic and
More informationROTANODE TM E7252X E7252FX E7252GX Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Electrical :
Technical Data TD ROTANODE TM E7252X E7252FX E7252GX Rotating Anode X-Ray Tube Housing Assembly High speed rotating anode X-ray tube housing assembly for high energy radiographic and cine-fluoroscopic
More informationRotating Anode X-ray Tube Assembly
RADII H18X H18Y Datasheet Rotating Anode X-ray Tube Assembly The tube unit is so constructed that an X-ray tube is sealed in a diagnostic type protective tube housing of electric shockproof, radiation
More informationRotating Anode X-ray Tube
Datasheet RADII KL74-1.0/2.0-125 Rotating Anode X-ray Tube Rotating anode X-ray tube for the purpose of general diagnostic X-ray procedures. Specially processed Tungsten faced molybdenum target of 74 mm
More informationMOBILEART eco C504-E009G
MOBILEART eco C504-E009G MobileArt eco Flexible Bedside Positioning Shimadzu s mobile X-ray system allows X-rays to be taken easily in limited spaces. This is made possible by the flexibility of the new
More informationRotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I
Technical Data TD ROTANODE E7239X E7239FX E7239GX 197 Rotating Anode X-Ray Tube Housing Assembly Rotating anode X-ray tube housing assembly for the purpose of general diagnostic X-ray procedures. Specially
More informationRotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Type B
Technical Data TD ROTANODE E7239X E7239FX E7239GX 0197 Rotating Anode X-Ray Tube Housing Assembly Rotating anode X-ray tube housing assembly for the purpose of general diagnostic X-ray procedures. Specially
More informationMobileDaRt Evolution MX8 Version
PD504-021 Mobile X-ray System MobileDaRt Evolution MX8 Version MX8c type GENERAL The MobileDaRt Evolution is a general-purpose mobile digital X-ray system, which can be freely moved throughout a hospital
More informationProduct Information PI
Product Information PI TOSHIBA X-RAY TUBE D-045 Stationary Anode X-ray Tube Especially designed for dental radiography unit. This tube has focus 0.4, and is available for maximum tube voltage 70 kv. Installed
More informationTechnical data CAMARGUE CS-VH50/300. VARIABLE Height Bucky Table With Ceiling Suspension
Technical data VARIABLE Height Bucky Table With Ceiling Suspension Model Variations CAMARGUE FH (Fixed Height) CAMARGUE FH Tomo CAMARGUE FH Ceiling suspension CAMARGUE VH (Variable Height) CAMARGUE VH
More informationRotating Anode X-Ray Tube Housing Assembly. General Data
Technical Data TD ROTANODE E7252X E7252FX E7252GX 0197 Rotating Anode X-Ray Tube Housing Assembly High speed rotating anode X-ray tube housing assembly for high energy radiographic and cine-fluoroscopic
More informationCorsix R 32 Accu PRODUCT DATA
PRODUCT DATA Product data Rev. 1 (April 2011) Page Description and Configurations 3 Technical Features 4 Radiological characteristics 4 Operating characteristics 5 Mechanical characteristics 6 Size and
More informationSHIMADZU GENERAL RADIOGRAPHIC SYSTEM
C1-E023B SHIMADZU GENERAL RADIOGRAPHIC SYSTEM SHIMADZU CORPORATION. International Marketing Division 3. Kanda-Nishikicho 1-chome, Chiyoda-ku, Tokyo 101-8448, Japan Phone: 81(3)3219-5641 Fax. 81(3)3219-5710
More informationIndustrial X-ray Tube KL
Description stationary anode x-ray tube is a highly popular and proven side window x-ray tube, which has focus 1.0 mm, is designed for non-destructive x-ray inspection. stationary anode x-ray tube can
More informationDistributed by. Ecotron Anyview Series. The Intelligent C-Arm System
Distributed by Ecotron Anyview Series The Intelligent C-Arm System The Ecotron Anyview Series is a new standard for C-arm imaging Excellent radiographic imaging at an economical price Advanced X-ray Generator
More informationDigital Panoramic X- Ray unit. Product Data
Digital Panoramic X- Ray unit Product Data Standard examination programs Standard panoramic: adult/child panoramic exam TMJ open/close mouth: 4 slices are taken in the same image (left/right condyle, open/close
More informationDigital Radiography System
www.drgem.co.kr GXR-SD SERIES GXR-SD SERIES Digital Radiography System GXR-SD Series www.drgem.co.kr High Performance and Reliability The Optimal System for Digital Solution The GXR-SD Series is a diagnostic
More informationSONIALVISION G4 Multi-purpose Digital R/F System C506-E075
SONIALVISION G4 Multi-purpose Digital R/F System C506-E075 Selecting the best for every examination environment BEST in CLASS Multi-purpose Digital R/F System 2 With the Sonialvision G4, Shimadzu offers
More informationSONIALVISION G4 Multi-purpose Digital R/F System C506-E075
SONIALVISION G4 Multi-purpose Digital R/F System C506-E075 Selecting the best for every examination environment BEST in CLASS Multi-purpose Digital R/F System With the Sonialvision G4, Shimadzu offers
More informationSONIALVISION G4 Multi-purpose Digital R/F System
C506-E075A SONIALVISION G4 Multi-purpose Digital R/F System Founded in 1875, Shimadzu Corporation, a leader in the development of advanced technologies, has a distinguished history of innovation built
More informationMXRP-160C. Product Description. Product Specifications
MXRP-160C Product Description The MXRP-160C is an unipolar water-cooled tube assembly with integrated radiation protection. It comprises a single focal spot, a tungsten anode and a panoramic beam. The
More informationBCA 9SK. 60 Hz on request Absorbed current on Stationary Vac and Vac in fluoro mode
ELECTRICAL CHARACTERISTICS Voltage 230 Vac ±10% monophase standard 105 / 115 / 125 / 220 / 240 Vac ±10% monophase on request Frequency 50 Hz standard 60 Hz on request Absorbed current on Stationary 4.5
More informationStationary Anode X-Ray Tube. General Data
Technical Data TD TOSHIBA X-RAY TUBE D-041 D-041S D-041SB Stationary Anode X-Ray Tube Especially designed for dental radiography unit. Provided with an insulation cylinder (D-041S) and lead cylinder. (D-041SB)
More informationMXHF-1500RF is controlled by Digital key panel console that displays KV, ma and mas with APR menu programmed.
R/F TV X-RAY SYSTEM DIAGNOSTIC RADIOGRAPHIC FLUOROSCOPIC TV SYSTEM MXHF-1500RF SYSTEM OUTLINE Product Data No. 041021-01 MXHF-1500RF is controlled by Digital key panel console that displays KV, ma and
More informationMammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over
Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over a lifetime Breast cancer screening programs rely on
More informationBCA 9RK. 60 Hz on request Absorbed current on Stationary Vac and Vac in fluoro mode
ELECTRICAL CHARACTERISTICS RADIOLOGICAL DATA MONOBLOC Voltage 230 Vac ±10% monophase standard 105 / 115 / 125 / 220 / 240 Vac ±10% monophase on request Frequency 50 Hz standard 60 Hz on request Absorbed
More informationHIGH FREQUENCY X-RAY MONOBLOCK 3.5kW
HIGH FREQUENCY X-RAY MONOBLOCK 3.5kW The high frequency X-Ray monoblock consists of an inverter and oil-filled tank which houses the high voltage transformer and tube. It has been designed and developed
More informationMILADY. Product Data. Page 1 of 8
Page 1 of 8 The MILADY Mammographic Unit offers the best quality-to-price ratio to our customers worldwide. The unit advanced technology together with the application of industrial production standards,
More informationHIGH FREQUENCY X-RAY MONOBLOCK 3.5kW
HIGH FREQUENCY X-RAY MONOBLOCK 3.5kW The high frequency X-Ray monoblock consists of an inverter and oil-filled tank which houses the high voltage transformer and tube. It has been designed and developed
More informationARU-01CF Portable X-Ray NSN:
ARU-01CF Portable X-Ray NSN: 6525-01-468-1672 COMMAND l AIR OPERATION & MAINTENANCE MANUAL Table of Contents Introduction................................................................3 Purpose.............................................................3
More informationX-ray Tube and Generator Basic principles and construction
X-ray Tube and Generator Basic principles and construction Dr Slavik Tabakov - Production of X-rays OBJECTIVES - X-ray tube construction - Anode - types, efficiency - X-ray tube working characteristics
More informationARCO Rk.5 Digital Mobile C-Arm
Product Data ARCO Rk.5 Digital Mobile C-Arm Product Data 1 Easy to move INTRODUCTION Designed with the latest technology throughout, the ARCO Rk.5 set new standards for the excellence image quality ease
More informationChina Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW, 150kV Radiography System - HF50-R
China Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW, 150kV Radiography System - HF50-R Building 3, No.9, Jiuxianqiaodong Road, Chaoyang District, Beijing 100015, P.R. China E-mail:
More informationDENTAL RADIOGRAPHY KAMARUL AMIN BIN ABU BAKAR
DENTAL RADIOGRAPHY KAMARUL AMIN BIN ABDULLAH @ ABU BAKAR Components of the Dental X-Ray Machine Dental x-ray machines may vary somewhat in size and appearance, but all machines will have three primary
More informationX-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage
X-rays Ouch! 1 X-rays X-rays are produced when electrons are accelerated and collide with a target Bremsstrahlung x-rays Characteristic x-rays X-rays are sometimes characterized by the generating voltage
More informationGE AMX 4+ Portable X-Ray
GE AMX 4+ Portable X-Ray Typical Manufacturer s Picture GE Healthcare s AMX-4+ analog X-ray system provides high-performance in a compact, easy-to-maneuver package. The rotating arm and tube simplify positioning
More informationProduct Information PI
Product Information PI ANALIX A-41 Series / A-41L Series The ANALIX A-41 (Short Body Type) / A-41L (Long Body Type) series, a water-cooled, grounded anode X-ray tube designed for X-ray diffractometry.
More informationPractix. Mobile Radiography. Changing its point of view comes naturally. Practix 300
Practix 300 Specifications Practix Mobile Radiography Changing its point of view comes naturally Practix 300 With its swiveling telescopic tube arm and rotatable column, the Practix 300 adds a new and
More informationSPRINGFIELD TECHNICAL COMMUNITY COLLEGE ACADEMIC AFFAIRS
SPRINGFIELD TECHNICAL COMMUNITY COLLEGE ACADEMIC AFFAIRS Course Number: RADG 212 Department: Radiography Course Title: Equip. Operation & Maint. Semester: Spring Year: 1997 Objectives/ Unit One: The X-ray
More informationPractix. Mobile Radiography. Constantly on the move, and yet never tired. Practix 160
Practix 160 Specifications Practix Mobile Radiography Constantly on the move, and yet never tired Practix 160 The mobile X-ray system Practix 160 offers ideal solutions for all routine examinations in
More informationVersion 1.0. TechnicVR. Student Guide
Version 1.0 TechnicVR s h a d e r w a r e. c o m Student Guide TechnicVR s h a d e r w a r e. c o m Student Guide shaderware 2008 PO Box 103 Saltburn Cleveland TS12 1WP w w w. s h a d e r w a r e. c o
More informationRADspeed Pro GENERAL RADIOGRAPHIC SYSTEM Automatic C501-E027B
RADspeed Pro GENERAL RADIOGRAPHIC SYSTEM Automatic C501-E027B High-Performance General Radiographic System Improves Workflow and Achieves Dose Reduction GENERAL RADIOGRAPHIC SYSTEM Automatic This state-of-the-art
More informationX-ray Tube and Generator Basic principles and construction
X-ray Tube and Generator Basic principles and construction Dr Slavik Tabakov - Production of X-rays and Patient Dose OBJECTIVES - X-ray tube construction - Anode - types, efficiency - Classical X-ray generator
More informationYSF - 300/DAR i
C506-E067 Integrated Digital R/F System YSF - 300/DAR - 8000i photo shown with optional I.I. cover A Fully Integrated Digital R/F System Expanding the Clinical Boundaries. With more than 130 years of dedication
More informationTomosynthesis. Energy Subtraction. Long View Imaging
Freedom and Flexibility in Imaging Experience a wide range of applications targeted to improve diagnostic capabilities combined with a precise design that facilitates imaging. With unique image processing
More informationSPECIFICATION. Kilovoltage X-ray calibration system for protection and diagnostic level dosimetry. Prepared by
SPECIFICATION Kilovoltage X-ray Prepared by Igor Gomola, Technical Officer, Project ECU6023, Date 2015-Oct-06 Revision Date Status Comments 0.1 2015-Oct-06 Draft Igor Gomola Page 1 of 12 1. Scope This
More informationAeroDR X60. Motorized X-ray System
AeroDR X60 Motorized X-ray System AeroDR X60 2 MOTORIZED X-RAY SYSTEM The AeroDR X60 is a high quality, cost effective, compact motorized floor mounted X-ray system, built around Konica Minolta s renowned
More informationChina Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW Digital RF System - HF51-5
China Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW Digital RF System - HF51-5 #3, No.9, Jiuxianqiaodong Road, Chaoyang District, Beijing 100015, P.R. China E-mail: international@wandong.com.cn
More informationX-RAYS - NO UNAUTHORISED ENTRY
Licencing of premises Premises Refer Guidelines A radiation warning sign and warning notice, X-RAYS - NO UNAUTHORISED ENTRY must be displayed at all entrances leading to the rooms where x-ray units are
More informationNew spectral benefi ts, proven low dose
New spectral benefi ts, proven low dose Philips MicroDose mammography SI, technical data sheet Philips MicroDose SI with single-shot spectral imaging is a fullfi eld digital mammography solution that delivers
More informationDisclosure to Promote the Right To Information
इ टरन ट म नक Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information
More informationQuality Design Because you pay more and more attention to the look and effectiveness of your practice
Quality Design Because you pay more and more attention to the look and effectiveness of your practice ACTEON has developed X-Mind unity with: - Uncompromising design - Clean lines - Proven quality - Superior
More informationX-RAY IMAGING EE 472 F2017. Prof. Yasser Mostafa Kadah
X-RAY IMAGING EE 472 F2017 Prof. Yasser Mostafa Kadah www.k-space.org Recommended Textbook Stewart C. Bushong, Radiologic Science for Technologists: Physics, Biology, and Protection, 10 th ed., Mosby,
More informationOEM s #1 Choice for X-Ray Sources and Generators. Focus on Performance, Reliability, Form Factor, and Versatility.
OEM s #1 Choice for X-Ray Sources and Generators Focus on Performance, Reliability, Form Factor, and Versatility www.vjtxray.com Applications Security, Industrial NDT, Food & Pharmaceutical, Quality &
More informationProX Intraoral X-ray. PLANMECA is proud to introduce a new intraoral X-ray unit to its comprehensive collection of imaging products- the ProX.
The premium intraoral X-ray unit... ProX Intraoral X-ray PLANMECA is proud to introduce a new intraoral X-ray unit to its comprehensive collection of imaging products- the ProX. This advanced unit provides
More informationM517-E077A O P E R A T I O N G U I D E
O P E R A T I O N G U I D E M517-E077A This operation guide is intended to compliment each "Operation Manual" of Sonialvision Safi re II / Safi re 17 and concisely describes its basic operations. Prior
More informationPET1606J2F. Pilani Electron Tubes & Devices Pvt. Ltd. Water Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1606J2F
Water Cooled Triode For Industrial RF Heating Drop in equivalent of BW1606J2F Output Power: 30 kw Anode voltage: 10 kv max Anode dissipation: 15 kw max Frequency up to 30 MHz Manufactured in India, in
More informationUsing Carbon Nano-Tube Field Emitters to Miniaturize X-Ray Tubes
Using Carbon Nano-Tube Field Emitters to Miniaturize X-Ray Tubes Authors: Martin Pesce, RT(R), Xiaohui Wang, PhD, Peter Rowland X-rays are produced by the impact of an accelerated electron beam on a tungsten
More information- KiloVoltage. Technique 101: Getting Back to Basics
Why do I need to know technique? Technique 101: Getting Back to Basics Presented by: Thomas G. Sandridge, M.S., M.Ed., R.T.(R) Program Director Northwestern Memorial Hospital School of Radiography Chicago,
More informationDose Reduction and Image Preservation After the Introduction of a 0.1 mm Cu Filter into the LODOX Statscan unit above 110 kvp
Dose Reduction and Image Preservation After the Introduction of a into the LODOX Statscan unit above 110 kvp Abstract: CJ Trauernicht 1, C Rall 1, T Perks 2, G Maree 1, E Hering 1, S Steiner 3 1) Division
More informationC506-E064. Full digital system. Printed in Japan A-NS
C506-E064 Full digital system Printed in Japan 6295-08807-30A-NS Full digital system Highest Image Quality in Its Class Comprehensive Full-Digital System FLEXAVISION is a full-digital R/F system equipped
More informationSAMSUNG SMART DIGITAL RADIOGRAPHY. XGEO GU60A series REDEFINING ERGONOMICS
SAMSUNG SMART DIGITAL RADIOGRAPHY XGEO GU60A series REDEFINING ERGONOMICS U-arm Positioner (Fully Automated) The XGEO GU60A/60A-65 is a universal, fully motorized system. Its unique U-arm rotates +120
More informationRULES OF TENNESSEE DEPARTMENT OF ENVIRONMENT AND CONSERVATION DIVISION OF RADIOLOGICAL HEALTH CHAPTER USE OF X-RAY APPARATUS
RULES OF TENNESSEE DEPARTMENT OF ENVIRONMENT AND CONSERVATION DIVISION OF RADIOLOGICAL HEALTH CHAPTER 0400-20-06 USE OF X-RAY APPARATUS TABLE OF CONTENTS 0400-20-06-.01 Purpose 0400-20-06-.06 Veterinary
More information1. Carlton, Richard R., and Arlene M. Adler. Principles of Radiographic Imaging: An Art and a Science, 5th edition (2013).
CODE: RADT 151 INSTITUTE: Health Science TITLE: Radiographic Exposure DEPARTMENT: Radiologic Technology COURSE DESCRIPTION: This course covers the principles of radiographic exposure selection and manipulation
More informationAtomscope PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL. Version 1.0
Atomscope PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL Version 1.0 Thank you for purchasing our HFX90V portable veterinary x-ray unit. We are confident that you will be pleased with the radiographs
More informationSHIMADEN THREE-PHASE POWER REGULATOR
SHIMADEN THREE-PHASE POWER REGULATOR SERIES PAC30Z Easy Wiring With 2-Phase Control Low-Noise Design Wide Capacity Selection (18~135A) Output Standard Feature SPECIFICATIONS Control input: Current capacity:
More informationTHE PANTAK THERAPAX SXT 150
THE PANTAK THERAPAX SXT 150 combines the safety and ease-of-use of photon radiation therapy with state-of-the-art technology, including microprocessor control and solid-state electronics. Using Therapax,
More informationX band Magnetron. Water: Anode cavity Forced-air: Input ceramics and terminals Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent
X band Magnetron GENERAL DESCRIPTION MX7621 is a tunable X-band pulsed type magnetron intended primarily for linear accelerator. It is cooled with water and has a UG51/U (WR112) output coupling. It is
More informationPET1610F. Pilani Electron Tubes & Devices Pvt. Ltd. Forced-Air Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1610F
Forced-Air Cooled Triode For Industrial RF Heating Drop in equivalent of BW1610F Output Power: 30 kw Anode voltage: 9 kv max Anode dissipation: 10 kw max Frequency up to 30 MHz Manufactured in India, in
More informationRADIOGRAPHIC EXPOSURE
RADIOGRAPHIC EXPOSURE Receptor Exposure Receptor Exposure the that interacts with the receptor. Computed Radiography ( ) requires a. Direct Digital Radiography (DR) requires a. Exposure Indicators Exposure
More informationEnglish. Where quality becomes beauty
English Where quality becomes beauty Quality, Design, your image Because you pay more and more attention to the look and effectiveness of your practice. ACTEON SATELEC has developed X-Mind TM unity with:
More informationORTHOPANTOMOGRAPH OP 2D Quality and design
OP 2D Quality and design OP 2D OP 2D is a digital panoramic X-ray unit that combines distinctive design and reliable quality with all essential tools for standard panoramic imaging needs. OP 2D is part
More informationSvetlana 4CX7500A Radial Beam Power Tetrode
Svetlana CX7500A Radial Beam Power Tetrode T he Svetlana CX7500A is designed for audio and radio frequency applications. The Svetlana CX7500A has a directly-heated thoriated tungsten mesh filament for
More informationDIGITAL TABLE C506-E049E
DIGITAL TABLE C506-E049E Launched in 200, the Sonialvision Digital Table System was designed as the standard for the 2st Century. Stable image quality, a multitude of functions and a system design thought
More informationI. PERFORMANCE OF X-RAY PRODUCTION COMPONENTS FLUOROSCOPIC ACCEPTANCE TESTING: TEST PROCEDURES & PERFORMANCE CRITERIA
FLUOROSCOPIC ACCEPTANCE TESTING: TEST PROCEDURES & PERFORMANCE CRITERIA EDWARD L. NICKOLOFF DEPARTMENT OF RADIOLOGY COLUMBIA UNIVERSITY NEW YORK, NY ACCEPTANCE TESTING GOALS PRIOR TO 1st CLINICAL USAGE
More informationRemote Controlled R/F System C506-E056D
Remote Controlled R/F System C506-E056D Remote Controlled R/F system Numerous system configurations easily accommodate a wide variety of examinations The specifications of the main system components,
More informationX-band Magnetron. Cooling (note 5) Water Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent
X-band Magnetron GENERAL DESCRIPTION MX7637 is a tunable X-band pulsed type magnetron intended primarily for linear accelerator. It is cooled with water and has a UG51/U (WR112) output coupling. It is
More informationuniversal Digital Radiography (DR) System
Vision Air universal Digital Radiography (DR) System Technical Specification Vision Air is a state-of-the-art, universal, overhead digital radiography system capable of virtually all radiography examinations
More informationNuclear Associates
Nuclear Associates 07-591 Focal Spot Test Tool Users Manual February 2005 Manual No. 07-591-1 Rev. 2 2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks
More informationCompact High Intensity Light Source
Compact High Intensity Light Source General When a broadband light source in the ultraviolet-visible-near infrared portion of the spectrum is required, an arc lamp has no peer. The intensity of an arc
More informationDigital Radiography X-Ray System. X Twin with X Mobil Roesys GmbH [rshsmi] 1/11
Digital Radiography X-Ray System 2017 Roesys GmbH [rshsmi] 1/11 1 General specifications The system is intended to be installed with floor mounted components only. It enables spacesaving installation without
More informationGE Sensing & Inspection Technologies. The ISOVOLT Titan E X-ray Generator
GE Sensing & Inspection Technologies The Titan E X-ray Generator Robust, Reliable and Highly Accurate Stationary X-ray Generators for the Widest Range of Applications. The Reference Class for X-ray generators
More informationGE Inspection Technologies. The ISOVOLT Titan E X-ray Generator
GE Inspection Technologies The Titan E X-ray Generator Robust, Reliable and Highly Accurate Stationary X-ray Generators for the Widest Range of Applications. The Reference Class for X-ray generators is
More informationCOMPACT Diode Laser System (Water-Cooled)
COMPACT Diode Laser System (Water-Cooled) Easy-to-integrate CW system consists of a compact 19 (11HU including water-air-chiller), rack-mountable chassis and metal-armored fiber. Can be combined with DILAS
More informationMedical Imaging. Latest generation bucky room. system. radiology ahead
Medical Imaging Latest generation bucky room system radiology ahead system it grows efficiency, the productivity is on the up Moviplan ic System is the latest-generation X-ray equipment, combining all
More informationMULTIX PRO/TOP VERTIX PRO/TOP VERTIX Solitaire X-ray systems for radiographic rooms that make life easier
MULTIX PRO/TOP VERTIX PRO/TOP VERTIX Solitaire X-ray systems for radiographic rooms that make life easier Over 1,000 systems sold! MULTIX PRO/TOP VERTIX PRO/TOP VERTIX Solitaire Faster and safer diagnosis
More informationTECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS
TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) BIDDER s OFFER S. No. PARTICULARS BHEL SPECIFICATIONS 1.0 Area of Application The 300kV Constant potential
More informationS-band Magnetron. Tuner revolutions to cover frequency range 4.75 (note 3) Mounting position (note 4) Any Cooling (note 5) Water
S-band Magnetron GENERAL DESCRIPTION is a mechanical tuned pulsed type S-band magnetron intended primarily for linear accelerator. It is water cooled and has circle waveguide output type. It is designed
More informationDisclosure to Promote the Right To Information
इ टरन ट म नक Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information
More information2014 CINDE Toronto Portable X-ray & X-Ray Production
2014 CINDE Toronto Portable X-ray & X-Ray Production Nils Hase, Business Development Manager Portable X-Ray business unit Copenhagen and USA Technology with Passion 3 COMET Headquarters Flamatt Switzerland
More informationTECHNICAL DATA. GIOTTO IMAGE SDL/W is pre-arranged for Full Field Digital Biopsy examination with the patient in prone position.
Ver. 01/06/07 TECHNICAL DATA GIOTTO IMAGE SDL/W LOW DOSE, FULL FIELD DIGITAL MAMMOGRAPHY UNIT USING AMORPHOUS SELENIUM (a-se) TECHNOLOGY DETECTOR (pre-arranged for stereotactic biopsy with the same digital
More informationQuality imaging, practical investment. Philips DuraDiagnost specifications
Quality imaging, practical investment Philips DuraDiagnost specifications Table of contents 1. Overview of room configurations 3 2. Rooms 4 2.1 Efficiency room 4 2.2 Value room 6 2.3 Chest room 8 2.4 Optional
More informationCT-XGEO GC FTW EN
Samsung Electronics Co., Ltd. is a global leader in technology, opening new possibilities for people everywhere. Through relentless innovation and discovery, we are transforming the worlds of televisions,
More informationXRC X-Ray Calibration System
XRC X-Ray Calibration System Technical Description Contents 1. Equipment overview 2. X-ray Beam Specifications 3. The Control Console 4. Radiation Safety 5. Filters 6. X-ray Generator & Heat Exchange Equipment
More informationDigital medical imaging has significantly contributed to the improvement of diagnoses and the widespread use of less
RCS Paris B 337 934 483-012573-00b www.acteongroup.com Non contractual document - Ref. 707114 B - 03/2018 - Copyright 2018 ACTEON IMAGING. All rights reserved. No information or any part of this document
More informationMULTIX PRO/TOP, VERTIX Solitaire, VERTIX PRO/TOP
, VERTIX Solitaire, VERTIX PRO/TOP Modular X-ray systems for radiographic applications Data sheet www.siemens.com/healthcare s VERTIX Solitaire VERTIX PRO/TOP Modular X-ray systems for radiographic applications
More information