RSCC. Data Sheet. Load cells. Special features. Diagram of RSCC load cell. Design: 500 kg to 5 t. Design: 50 kg to 200 kg. B
|
|
- Jeffry Gregory
- 5 years ago
- Views:
Transcription
1 RSCC Load cells Data Sheet Special features - Load cell with SG measurement system - aximum capacities: 50 kg to 5 t - Hermetically sealed (IP68) - Rust resistant materials - Legal for trade to 3000 divisions, test report per OIL R60 for class III scales - eets EC requirements as per EN Six wire circuit - Ex protection version per TEX (optional) Diagram of RSCC load cell Load application (metric thread) Connection cable Load transfer (metric thread) Design: 50 kg to 200 kg Design: 500 kg to 5 t 1
2 Dimensions (in mm; 1 mm = inches) Cable: Length 7.6 m Outside diameter 5 mm aterial PVC D 24 C B Without adapter for cable 12x1.5 With adapter for cable aximum capacity B C D 50 kg kg kg HB 2
3 Dimensions (in mm; 1 mm = inches) Cable: Length 7.6 m Outside diameter 5 mm aterial PVC D E C B Without adapter for cable 12x1.5 With adapter for cable aximum capacity B C D E 500 kg t t x2 5 t x2 Cable protection (Option 6 required: with adapter for a cable ; customer side cable protection version) Cable *, (provided by customer) comprising: Screwed cable gland* Flexible cable protection tubing* O ring (provided by customer) Unscrew the 12 sleeve and replace with an 12 threaded tube coupling * Supplier such as Flexicon ( 3 HB
4 ounting accessories (to be ordered separately): Dimensions (in mm; 1 mm = inches) Center bearing collar W H D Rigid force transfer B G B F X a.f. H max /H min Emin/Emax aterial: Tempered steel, galvanized roller bearing steel PTFE/bronze corrugated foil B aximum capacity Weight (kg) B H7 D F G H W X a.f. 50 kg to 100 kg kg to 1 t t to 5 t x aximum capacity H min H max E min E max B (N m) 50 kg kg kg kg t t t HB 4
5 Specifications Type ccuracy class as per OIL R 60 Number of load cell verification intervals (n LC ) RSCC C % of C n aximum capacity (E max ) 50 kg 100 kg 200 kg 500 kg 1 t 2 t 5 t inimum load cell verification interval (v min ) % of E max Nominal (rated) sensitivity (C N ) mv/v 2 Sensitivity tolerance % 0.25 Zero signal mv/v Temperature coefficient of sensitivity (TK C ) 1) (20 C to 40 C) % of C n / (-10 C to 20 C) 10 K Temperature coefficient of zero signal (TK 0 ) Relative reversibility error (d hy ) 1) Non linearity (d lin ) 1) Creep upon loading (d cr ) over 30 min Input resistance (R LC ) (nominal) Output resistance (R 0 ) Insulation resistance (R iso ) G /100 V > 2 Reference excitation voltage (U ref ) Nominal (rated) supply voltage range (B U ) Nominal (rated) amb. temperature range (B T ) V to to +40 Operating temperature range (B tu ) -30 to +70 C Storage temperature range (B tl ) -50 to +85 Reference temperature (t ref ) 22 Limit load (E L ) 150 Breaking load (E d ) % of E max Relative perm. vibrational stress (F srel ) 70 (oscillation width as per DIN 50100) Nominal (rated) displacement at maximum mm capacity (s nom ), 0.05 mm Weight (G), approx. kg Degree of protection per EN (IEC 529) IP 68 (test conditions 1 m water column / 100 h) Cable length, six wire configuration 7.6 m as standard aterial: easuring body stainless steel 2) Cable entry stainless steel / neoprene Cable sheath PVC 1) The values for non linearity (d lin ), relative reversibility error (d hy ) and temperature coefficient of sensitivity (TK C ) are recommended values. The sum of these values is within the cumulated error limits according to OIL R60. 2) s per EN Cable assignment (6 wire configuration) With this cable assignment, the output voltage at the measuring amplifier is positive in the tensile direction when the transducer is loaded. (gray) (black) (white) (blue) (green) (red) (-) Sensing element (-) Excitation (-) Signal (+) Excitation (+) Sensing element (+) Signal (-) Shielding/drain wire, connected to enclosure ground 5 HB
6 Product numbers (overview) RSCC load cells aximum capacity Order no. 50 kg 1-RSCC3/50KG kg 1-RSCC3/100KG kg 1-RSCC3/200KG kg 1-RSCC3/500KG-1 1 t 1-RSCC3/1T-1 2 t 1-RSCC3/2T-1 5 t 1-RSCC3/5T-1 RSCC load cells, optional versions Option 1: Design N standard C3 C3 (OIL) kg kg kg kg t t t Option 2: ccuracy class Option 3: aximum capacity Option 4: Explosion protection (per TEX) N no TEX 1 TEX Zone and F 2 TEX Zone (for non-conductive dust) S standard (7.6 m) m m Option 5: Cable length N no Option 6: dapter for cable with adapter for cable Product no. K RSCC N C 3 Ex protection versions per TEX: II 2G Ex ia II C T4 and T6 (Zone 1) * ) II 2D ExtD 21 IP67 T80 C (Zone 21) * ) II 3G Ex n II T6 (Zone 2) II 3D ExtD 22 IP67 T80 C (Zone 22 for non conductive dust) * ) with EC type examination certificate RSCC accessories aximum capacity ZG (knuckle eyes top and bottom) 50 kg to 100 kg 1-U1R/200KG/ZGW 200 kg to 1 t 1-U2/1T/ZGUW 2 t to 5 t 1-U2/5T/ZGUW odifications reserved. ll product descriptions are for general information only. They are not to be understood as a guarantee of quality or durability and do not constitute any liability whatsoever. Hottinger Baldwin esstechnik GmbH Im Tiefen See Darmstadt Germany Tel Fax: E mail: info@hbm.com
S9M. Force Transducer. Special features. Data sheet
S9 Force Transducer Special features - Tensile/compressive force transducer - ccuracy class 0.02 - Hermetically encapsulated (IP68) - Rust-resistant materials - vailable in different cable lengths and
More informationSingle point load cell
PW15AH Single point load cell Special features - Nominal load 10 kg... 100 kg - Stainless steel - High ratio of minimum verification interval Y - Industrial Footprint (SP4M) - Degree of Protection IP68;
More informationZ6... Data sheet. Load cell. Special features. Dimensions (in mm; 1 mm = inches) B en HBM: public 1
Z6... Load cell ata sheet Special features Welded-on metal bellows (rated) loads: 5 kg 1 t Load cells and installation aids made of rust-resistant materials Verifiable up to 6000 divisions, test report
More informationSingle point load cell
PW15AH Single point load cell Special features - Nominal load 10 kg... 100 kg - Stainless steel - High ratio of minimum verification interval Y - Industrial Footprint (SP4M) - Degree of Protection IP68;
More informationLoad cell. Special features. Data sheet
Z6R Load cell Special features - Nominal (rated) loads: 20 kg 200 kg - Welded-on robust cover - Load cells made of rust-resistant materials - Easy to clean - Same dimensions like Z6F - Verifiable up to
More information100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features
C16A 100/200/400 t Self-centering pendulum lead cells Special features - Self restoring function - Nominal (rated) loads: 100 t, 200t and 400t - Simple installation - Rust resistant materials, laser welded,
More informationU2B. Force Transducer. Special features. Data sheet
U2B Force Transducer Special features - Tensile/compressive force transducer - Non rusting, degree of protection IP67 - Can be configured with different cable lengths, plug fitting and TEDS on request
More informationU2B. Data sheet. Force Transducer. Special features. B en
U2B Force Transducer Special features Data sheet Tensile/compressive force transducer Non-rusting, degree of protection IP67 Can be configured with different cable lengths, plug fitting and TEDS on request
More informationZ6... Data Sheet. Load cell. Special features. Dimensions (in mm; 1 mm = inches) B en 1
Z6... Load cell ata Sheet Special features - Welded on metal bellows - Nominal (rated) loads: 5 kg 1 t - Load cells and installation aids made of rust resistant materials - Verifiable up to 6000 parts,
More informationU9C. Data sheet. Force Transducer. Special features. B en
U9C Force Transducer Data sheet Special features Tensile/compressive force transducer Accuracy class 0.2 Nominal (rated) forces 50 N 50 KN Non-rusting, protection class IP67 Configurable with different
More informationC9C. Force Transducer. Special features. Data sheet
C9C Force Transducer Special features - Compact design compressive force transducer - Accuracy class 0.2 - Nominal (rated) forces 50 N to 50 kn - Configurable with different cable lengths, plug assembly
More informationU10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch]
U10M Force Transducer Special features - Precise and robust tensile/compressive force transducer for static and dynamic measurement tasks - High lateral force and bending moment stability, the effect of
More informationU15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants
U15 Force transducer Special features - Tensile/compressive force transducer - Nominal (rated) forces 2.5 kn to 2.5 MN - lass 0.5 to ISO 376 in force measurement range between 10% and 100% of the nominal
More informationPW6C. Single point load cells. Special features. Data sheet
PW6C Single point load cells Special features - Max. capacities: kg... 40 kg - Aluminum - Accuracy class CMR & C6 - Off center load compensated - Shielded connection cable - Different cable lengths and
More informationC10. Data sheet. Force transducer. Special features. B de
C10 Force transducer Data sheet Special features Force transducer for static and dynamic applications Made of non-rusting materials Precise (accuracy class from 0.03) Numerous options (double bridge, TEDS,
More informationInductive Standard Displacement Transducers
WA Inductive Standard Displacement Transducers Special features - Available as displacement probe or with detachable plunger - Good thermal stability in the event of temperature gradients - Space saving,
More informationData sheet. P3 Top Class BlueLine. P3MBP BlueLine. Ultra-high pressure transducers to 15,000 bar. Special features
Ultra-high pressure transducers to 1,000 bar Data sheet Special features P Top Class BlueLine PMBP BlueLine - For static and dynamic pressure variance, pressure peaks and pressure fluctuations - Principle
More informationE *) F 15. H 12 h9. 5.5f7 8h6. a./f approx. 0.5mm Free stroke. Displacement. Initial stroke
Displacement probe Plunger WA Inductive Standard Displacement Transducers Special features Displacement probe and transducer with detachable plunger Good thermal stability in the event of temperature gradients
More informationSpecifications Type WA2 WA10 WA20 WA50 WA100 WA200 WA300 WA500 Nominal displacement mm Nomi
Displacement probe WA Inductive Standard Displacement Transducers Special features Data Sheet Plunger Displacement probe and transducer with detachable plunger Good thermal stability in the event of temperature
More informationLoad Cells Shear beam load cells SIWAREX WL230 SB-S SA
oad cell Overview Combined error comb Repeatability v ±0.0% C n ±0.0% C n The shear beam load cell is particularly suitable for implementation in container, overhead rail conveyor and platform scales.
More informationT22. Data Sheet. Torque transducer. Special features. Installation example with two bellows couplings. B en
T22 Torque transducer Data Sheet Special features - Nominal (rated) torques N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m, 00 N m and 1 kn m - Nominal (rated) rotational speeds of 9000 rpm to 16 000 rpm
More informationMDEX. on customized sensors. Technical information. Torque transducer. CS-T-04-MDEX Special features
MDEX Torque transducer CS-T-04-MDEX Special features - Explosion proof acc. to ATEX 95 - Exx II 2 G Ex deq IIC T4 - Nominal (rates) torque of 100kNm, 130kNm and 150kNm - HBM Accuracy Class 0,1 - Digital
More informationData Sheet. Absolute pressure transducer Nominal (rated) pressure 10 bar to 3000 bar. Special features
P3 Top Class P3MB version with fixed cable P3MBP version with plug connection TEDS: Transducer Electronic Data Sheet P3 Absolute pressure transducer Nominal (rated) pressure 10 bar to 3000 bar Special
More informationT10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en
T10FS Torque Flange Data Sheet Special features Nominal (rated) torques: 100 NVm, 200 NVm, 500 NVm, 1 knvm, 2 knvm, 3 knvm, 5 knvm, 10 knvm Nominal speed from 12,000 rpm to 24,000 rpm Low rotor weights
More informationT22. Torque transducer. Special features. Data sheet
T22 Torque transducer Special features - Nominal (rated) torques 0.5 Nm, 1 Nm, 2 Nm, 5 Nm, Nm, Nm, 50 Nm, 0 Nm, 0 Nm, 500 Nm and 1 knm - Nominal (rated) rotational speed up to 000 rpm (depending on measuring
More informationT40FM. Data Sheet. Torque flange. Special features. Overall concept. B en
T40FM Torque flange Special features Data Sheet - Nominal (rated) torque: 15 kn m, 20 kn m, 25 kn m, 30 kn m, 40 kn m, 50 kn m, 60 kn m, 70 kn m and 80 kn m - Nominal (rated) rotational speed up to 8000
More informationT10F. Data Sheet. Torque Flange. Special features. Installation example T10F. B en
T10F Torque Flange Data Sheet Special features Extremely short design High permissible dynamic loads High permissible transverse forces and bending moments Very high torsional stiffness Contactless Selectable
More informationelectronics Data Sheet Industrial Amplifier Special features Dimensions (in mm; 1 mm= inches) B en
C l i p electronics Industrial Amplifier Data Sheet Special features Amplifier and additional units for strain gauge full bridges and inductive half and full bridges Modules for mounting onto support rails
More informationT40FH. Torque flange. Special features. Data sheet
T40FH Torque flange Special features - Nominal (rated) torques: 100kNm, 125kNm, 150kNm, 200kNm, 250kNm, 300kNm - Nominal (rated) rotational speed of 2000 rpm up to 3000 rpm - Compact design - Version for
More informationABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS2000S Hermetically sealed bending beam load cell
BB ME SURE ME NT & N L YT ICS D T SHE ET 9QGPS2000S Hermetically sealed bending beam load cell 2 Measurement made easy High-end load cell combining high accuracy with high resistance in harsh environment.
More informationSpecifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0
Digibar II: PE00, PE50 Digital pressure gage Special features Data Sheet PE00 PE50 Operated as manometer with battery operation and Operated as pressure measurement transmitter with 420 current output,
More informationOperating manual. Force transducer with strain gage measuring system C9B. A en. hvordan man bruger astrologi med tibetanske medicin
Operating manual Force transducer with strain gage measuring system C9B hvordan man bruger astrologi med tibetanske medicin C9B Contents 3 Page Safety instructions..............................................
More informationTB2. Torque reference transducer. Special features. Data sheet
T2 Torque reference transducer pecial features tandard version - ccuracy class 0.03 - ominal (rated) s 100 m, 200 m, 500 m, 1 k m, 2 k m, 3 k m, 5 k m and 10 k m - High permissible oscillation width -
More informationTension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.
Force Tension/compression force transducer With thin film technology up to 100 kn Models F2301, F23C1, F23S1 tecsis data sheet FO 51.17 Applications Crane systems and hoists Industrial weighing technology
More informationT40B. Torque Flange. Special features. Data sheet. Overall concept
T40B Torque Flange Special features - Nominal (rated) torques 50 N m, 0 N m, 200 N m, 500 N m, 1 kn m, 2 kn m, 3 kn m, 5 kn m and kn m - Nominal rated rotational speed up to 24000 rpm (depending on nominal
More informationSUNSTAR 传感与控制
SUNSTAR 传感与控制 http://www.sensor-ic.com/ HBM Mess- und Systemtechnik GmbH Electrical measurement of mechanical quantities Operating manual Force transducer with strain gauge measuring system C9B B 20.C9B.20
More informationTension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.
Force Tension/compression force transducer With thin film technology up to 100 kn Models F2301, F23C1, F23S1 WIKA data sheet FO 51.17 Applications Crane systems and hoists Industrial weighing technology
More informationMX1615. Data sheet. Bridge/strain gauge amplifier
MX1615 Bridge/strain gauge amplifier Data sheet Special features 16 individually configurable inputs Connection of strain gauges in quarter-, half- and full-bridge Bridge excitation : DC or carrier frequency
More informationCANHEAD. Data Sheet. Special features. Distributed measurement acquisition. B en
CANHEAD Data Sheet Special features 10channel amplifier modules for installation close to measuring points Measured data transmission to communication master via field bus Base modules for individual SGs,
More informationResistance Thermometers Model Series TR7X0, Sheathed Design
Electrical Temperature Measurement Resistance Thermometers Model Series TR7X0, Sheathed Design WIKA Data Sheet TE 60.40 Applications T Suitable for all industrial and laboratory applications Special Features
More informationMX1601B-R. Ultra rugged Standard Amplifier. Data sheet. Special features. Block diagram
MX1601B-R Ultra rugged Standard Amplifier Special features - 16 individually configurable inputs (electrically isolated) - Support of 60 V, 10 V, 100 mv, 20 ma or IEPE on all channels - Sample rate: up
More informationType PB Load Cell. Approvals OIML approval to C3 (Y = 7 500; Y = for 375 kg capacity)
Type PB Load Cell IP65 Product Description The type PB is a very low profile planar beam load cell. Its unique Flintec design allows for an extremely low scale construction. Using 3 or 4 type PB load cells
More informationMX1615B-R. Ultra-rugged Bridge Amplifier. Special features. Data sheet. Block diagram
MX1615B-R Ultra-rugged Bridge Amplifier Special features - 16 individually configurable inputs - Connection of strain gages in half-, full- or quarter-bridge (120 Ohm or 350 Ohm) - Bridge excitation: DC
More informationSensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering
Change from one to two columns Data Sheet 10/10-3.61-EN Rev. D SensyTemp TSB (B R) Resistance thermometer for building automation, machine construction and environmental engineering Measurement made easy
More informationLoad pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1
Force Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1 WIKA data sheet FO 51.18 Applications Crane systems and hoists Industrial weighing technology Machine building and plant
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationTerms and expressions for specifying torque transducers
Terms and expressions for specifying torque transducers Terms and expressions for specifying torque transducers Metrological properties of the torque measuring system Accuracy class The accuracy class
More informationLoad pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1
Force Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1 tecsis data sheet FO 51.18 Applications Crane systems and hoists Industrial weighing technology Machine building and plant
More informationMX1601B R. Data Sheet. Ultra-rugged Standard Amplifier
MX1601B R Ultra-rugged Standard Amplifier Data Sheet Special features 16 individually configurable inputs (electrically isolated) Support of 60 V, 10 V, 100 mv, 20 ma or IEPE on all channels Sample rate:
More informationTQ 402 & TQ 412 / EA 402 / Proximity System : TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner FEATURES
: TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner TQ 402 & TQ 412 / EA 402 / IQS 452 FEATURES Non-contacting measurement system based on eddy current principle Certified
More informationLoad pin Heavy Duty with thin film technology from 10 kn Models F5308, F53C8, F53S1
Force Load pin Heavy Duty with thin film technology from 10 kn Models F5308, F53C8, F53S1 tecsis data sheet FO 51.43 Applications Crane systems, hoists, offshore Industrial weighing technology Machine
More informationCondumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.
Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers
More informationMX1615B R. Data Sheet. Ultra-rugged Bridge Amplifier
MX1615B R Ultra-rugged Bridge Amplifier Data Sheet Special features 16 individually configurable inputs Connection of strain gages in quarter-, half- or full-bridge Bridge excitation: DC or carrier frequency
More informationTQ 401 / EA 401 / IQS 451. Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES
Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES Non-contacting measurement system based on eddy current principle Certified for use in potentially
More informationTechnical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10
Compression force transducer with Thin-film sensor Accuracy: 1 % Output signal: 4...20 ma; 2-wire, 0...10 VDC; 3-wire Optional Optional ATEX/IECEX II 2G Ex ib IIC T4/T3 for SIL3-Applications with 2-channel
More informationMultipoint measuring units UPM100 and Centipede100
OTTINGER ALDWIN ESSTECHNIK HBM Mess- und Systemtechnik GmbH Multipoint measuring units UPM100 and Centipede100 S 33.UPM100.10 e Multipoint measuring units UPM100 and Centipede100 HBM s multipoint measurement
More informationMX840B R. Data sheet. Ultra-rugged universal amplifier CAN. Special features. Block diagram. B en
MX840B R Ultra-rugged universal amplifier Data sheet Special features 8 individually configurable inputs (electrically isolated) Connection of more than 16 technologies per channel Sampling rates of up
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationCondumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.
Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers
More informationCondumax W CLS15 and CLS15D
Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationShear beam With thin-film technology from 2 kn Models F3301, F33C1, F33S1
Force Shear beam With thin-film technology from 2 kn Models F3301, F33C1, F33S1 Rated force From 0...2 kn Applications Industrial weighing technology Machine building and plant construction, manufacturing
More informationCable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*
Features Assembly Cable gland series for shielded EMC cables Brass nickel-plated or stainless steel AISI 316 Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex d, Ex e and Ex tb Metric and NPT
More informationENCODER. Analog Multiturn Encoder. Serie 8.M3661/M3681. Key-Features:
ENCODER Multiturn Encoder Serie 8.M366/M368 Key-Features: Content: Order Code...2 Technical Data...3 Outputs & Connections...5 Dimensions...6 - Shaft with max. 0 mm diameter - 0...5/0V, 4...20 ma analog
More informationMX1601B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en
MX1601B Universal amplifier Data Sheet Special features 16 individually configurable inputs (electrically isolated) Connection of of standard signals (60, 10, 100 m, 20 ma, IEPE) Individual data rates
More informationForce and weight measuring instruments
JJ Force sensors and load cells JJ Measurement amplifiers JJ Mechanical and electronic accessories JJ Combination units JJ Force calibration systems Force and weight measuring instruments DS_Force_and_weight_measuring_instruments
More informationTransducer transmitter BILT 4 II 2(1) G. Technical Manual
GB Transducer transmitter BILT 4 II 2(1) G Technical Manual Transducer transmitter BILT 4 Contents Introduction General... 3 Ex.safety description... 4 Technical data... 5 Installation General... 6 Mechanical
More informationOEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)
Electronic pressure measurement OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5) WIKA data sheet PE 81.65 Applications Hydraulics and pneumatics Pumps and compressors
More informationTechnical Information Smartec CLD18
TI01080C/07/EN/02.14 71264779 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application Compact measuring
More informationBestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax:
Load Cell F60X Bending beam load cell made of stainless steel, hermetically sealed. Approved up to 6000d R60 OIML. Level of protection IP 68. ATEX 94/9/CE version for hazardous area (option). Designed
More informationPressure transmitter for general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter for general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Machine tools Measurement and control technology
More informationOperating Manual Series Load Pins
Operating Manual 5301 Series Load Pins Safety note Use for intended purpose The force transducers in model series F5301 are intended for the measurement of static and dynamic tensile or compressive force.
More informationTechnical Specification FLUXUS ADM 8127B
FLUXUS ADM 8127B Liquid Ultrasonic Flowmeter for Permanent Installation in Hazardous Areas in the Mining Environment FLUXUS ADM 8127B is especially designed for the stationary use in explosive atmosphere
More informationCondumax CLS15 and CLS15D
Technical Information Condumax CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationMX460B-R. Rugged pulse and frequency measuring module. Data sheet. Special features. Block diagram
MX460B-R Rugged pulse and frequency measuring module Special features - Four individually configurable inputs (electrically isolated) - Measure any kind of digital signals up to 1 Mhz for measurement of
More informationIntrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H
Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments WIKA Data Sheet PE 81.51 Applications
More informationPressure transmitter for general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter for general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Machine tools Measurement and control technology
More informationBestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax:
Load Cell F60X Bending beam load cell made of stainless steel, hermetically sealed. Approved up to 6000d R60 OIML. Level of protection IP 68. ATEX 94/9/CE version for hazardous area (option). Designed
More informationMX440A. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en
MX440A Universal amplifier Data Sheet Special features 4 individually configurable inputs (electrically isolated) Connection of more than 12 transducers technologies Data rate: up to 19,200 Hz 24 bit A/D
More informationBenefits/Application. Class 00 according to ISO 376 in the range 10 % to 100 % Especially to trace back Force Standard Machines
Data sheet Force transfer standard Series KTN-Z/D (5 N 1000 kn) Benefits/Application Class 00 according to ISO 376 in the range 10 % to 100 % For static tensile and compressive forces Especially to trace
More informationPressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Ship building Measurement and control technology
More informationConnection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition
Converter Connection 1-channel EEx ia IIC for 4-wire and 6-wire bridges Analogue output 0/4 ma... 20 ma or 4mA...-12mA Full bridge load cells and strain gauges circuit for resistance bridges up to 17 Ω
More informationElectrical Temperature Measurement
Electrical Temperature Measurement Resistance Thermometers Model TR10-B, for Additional Thermowell Applications Machinery, plant and tank construction Energy and power plant technology Chemical industry
More informationTQ 402 & TQ 412 / EA 402 / Proximity System. 三協インタナショナル株式会社東京 :Tel: 大阪 :Tel: 名古屋 :Tel: FEATURES
TQ 402 & TQ 412 / EA 402 / IQS 450 FEATURES Non-contacting measurement system based on eddy current principle TQ 402 Certified for use in potentially explosive atmospheres TQ 402 conforms to API 60 recommendations
More informationSpeed and Positioning Sensor GEL 2478
Speed and Positioning Sensor GEL 78 lso suitable for use explosion-hazardous areas Technical information Version 0.09 Key features Contactless measurement of linear or rotational movements One or two channels
More informationWS12EX Position Sensor with Analog output Dust explosion-proof
Sensor for Hostile Environments Class IP67 Measurement Range: 0... 100 mm to 0... 3000 mm With Analog Output Dust Ex proof, category 3, zone 22 II 3D EEx T80 C IP67 Specifications Outputs Material Resolution
More informationDatasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C
Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P - 4-20mA output, default range supplied 0-100 C ENGLISH The TX203P RTD in-head mounted temperature transmitter connects
More informationInstallation Guide. English. FS62 Surface Mountable Strain Sensor
Installation Guide English FS62 Surface Mountable Strain Sensor Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 D-64239 Darmstadt Tel. +49 6151 803-0 Fax +49 6151 803-9100 info@hbm.com www.hbm.com
More informationInstallation Guide. English. FS62 Embedded Strain Sensor
Installation Guide English FS62 Embedded Strain Sensor Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 D-64239 Darmstadt Tel. +49 6151 803-0 Fax +49 6151 803-9100 info@hbm.com www.hbm.com HBM FiberSensing,
More informationIntrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F
Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE
More information7600 Isolated Digitizer and Receiver
7600 Isolated Digitizer and Receiver Data sheet GEN series Features and Benefits - Complete single-channel isolated analog input subsystem - Rugged enclosure for use in EMI hostile environments - Shock
More informationISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits
ISOBE5600 Isolated Probe Systems - ISOBE5600 Isolation system - ISOBE5600 Transient recorder Data sheet Features and Benefits ISOBE5600 Isolation system - Cost-effective - Fiber-optic isolation - Analogue-in
More informationProcess Protection Acoustic sensors for pump monitoring
coustic sensors for pump monitoring acoustic diagnostic unit Overview The acoustic diagnostic unit acoustically measures the structure-borne noise In the version for pump monitoring; on oscillating displacement
More informationDigital I/O Coupler (4-wire) Series 9413/21
Digital /O Coupler (4wire) > The digital /O coupler is used to connect 8 intrinsically safe contacts or proximity initiators and 4 intrinsically safe solenoid valves to a FOUNDATON TM fieldbus H1. > Galvanic
More informationOnline data sheet. ACM60B-S1KE13x06 ACM60 ABSOLUTE ENCODERS
Online data sheet ACM60B-S1KE1x06 ACM60 A B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Performance Number of steps per revolution Number of revolutions Ordering information
More informationOperating manual. 600 Hz Measuring Amplifier ME30. A en
Operating manual 600 Hz Measuring Amplifier ME30 ME30 Contents 3 Page Safety instructions............................................. 4 1 Measuring Amplifiers on Eurocards ME30.................... 8
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationIntrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F
Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE
More informationOnline data sheet TTK70-HXA0-K02 TTK70 MOTOR FEEDBACK SYSTEMS LINEAR HIPERFACE
Online data sheet TTK70-HXA0-K02 TTK70 TTK70-HXA0-K02 TTK70 A B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Performance Measuring step Measuring length Ordering information
More informationPrecision Junction Boxes
Precision Junction Boxes Accuracy and Stability All components are designed for high accuracy and long term stability. Precision SMT resistors and gold plated switches guarantee trouble free operation.