Single point load cell
|
|
- Gregory Potter
- 5 years ago
- Views:
Transcription
1 PW15AH Single point load cell Special features - Nominal load 10 kg kg - Stainless steel - High ratio of minimum verification interval Y - Industrial Footprint (SP4M) - Degree of Protection IP68; IP69K - Different cable lengths and other options available Data sheet Dimensions (in mm; 1 mm= inches) x0.5 Plug (see page 3) Connection cable (see page 3) (only 1x) 17.5
2 Specifications Type Accuracy class 1) PW15AH/PW15AHY (C3 MR) C3 Multi Range (MR) Max. number of load cell interval n LC 3000 Maximum capacity E max kg Min. LC verification interval v min g Ratio of minimum verification interval (PW15AH) Y Temperature effect on zero balance (PW15AH) TK 0 % of C n / 10 K Ratio of minimum verification interval (PW15AHY) Temperature effect on zero balance (PW15AHY) Y TK 0 % of C n / 10 K Maximum platform size mm 500 x 400 Sensitivity C n mv/v Zero balance Temperature effect on sensitivity 2) Temperature range: C [ F] C [ F] % of C TK n / C 10 K Hysteresis error 2) d hy Non linearity 2) d lin % of C Minimum dead load output return DR n Off center load error 3) ) Input resistance R LC Ω Output resistance R Reference excitation voltage U ref 5 Nom. range of excitation voltage B U V 1... Max. excitation voltage 15 Insulation resistance with 100 V DC R is GΩ > 1 Nominal temperature range B T [ F] Service temperature range B tu C [ F] [ F] Storage temperature range B tl [ F] Safe load limit * ) E L % of E max 150 * ) at max. eccentricity mm 160 Lateral load limit, static E lq % of E max 300 Breaking load E d 300 Deflect. at E max, approx. s nom mm < 0.5 Weight, approx. m kg 1.0 Protection class 5) Material Measuring element Cable sheath IP 68 (test conditions 100 h at 1 m water column); IP69K (water at high pressure, steam jet cleaning) 4) ) PVC 1) According to OIML R60 with P LC = 0.7 2) The data for Non linearity (d lin ), Hysteresis error (d hy ) and Temperature effect on sensitivity (TK C ) are typical values. The sum of these data meets the requirements according to OIML R60. 3) According to OIML R76 4) Following the definitions of the DIN 40050, part of 9, for road vehicles 5) According to EN60529 (IEC529) 6) According to EN HBM 2
3 Wiring code Connection wirh 6 wire cable (selectable cable length: 3 m; 6 m) Detailed description of the Pancon plug (CE100F26-6), 6 pole Shield (yellow) = Shield connected to load cell body Wrap connection 1 (white) = Measurement signal (+) Wrap connection 2 (red) = Measurement signal (-) Wrap connection 3 (black) = Excitation voltage (-) 4 Wrap connection 4 (blue) = Excitation voltage (+) 5 6 Wrap connection 5 (green) = Sense lead (+) Wrap connection 6 (grey) = Sense lead (-) blue marking Cable protection (to be implemented by the customer) Protective cable conduit system*, consisting of: cable gland* cable protection tube* O ring seal (customer side) Unscrew M sleeve and replace with M threaded tube coupling * Supplier, e.g. Comp. Flexicon, UK: sales@flexicon.uk.com Worldwide: export@flexicon.uk.com 3 HBM
4 Load application Load must not be applied to the side where the cable connection is located, as this would cause a force shunt. platform center load application connection cable mounting spacing washer (customer construction) Ordering codes PW15AH (Stainless steel, hermetically sealed) Type PW15AH PW15AHY Accuracy class C3-MR (OIML) (Multi Range) C3-MR (OIML) Comments Capacity 10 kg 20 kg 50 kg 100 kg Cable length 3 m (6-wire)- Order number 1-PW15AHC3/10KG-1 1-PW15AHC3/20KG-1 1-PW15AHC3/50KG-1 1-PW15AHC3/100KG-1 1-PW15AHY/10KG-1 1-PW15AHY/20KG-1 1-PW15AHY/50KG-1 HBM 4
5 PW15AH (Stainless steel, hermetically sealed), optional versions Order no. K PW15AH N Option 1: Mechanical version Standard MR Option 2: Accuracy C3-MR (OIML) Option 3: Capacity kg kg kg kg N AI1/21 AI2/22 Option 4: Explosion protection No explosion protection IECEx+ATEX Zone 1/21+FM, intrinsically safe II2G Ex ia IIC T6/T4 Gb/II2G Ex ia IIIC T5 C Db IECEx+ATEX Zone 2/22, not intrinsically safe II3G Ex na IIC T6/T4 Gc/II3D Ex tc IIIC T5 C Dc Option 5: Cable length 3 3 m 6 6 m N A Option 6: Miscellaneous without 2mV/V ±0.1% / 359 Ohm ±0.3 Ohm (aligned output, suitable for connection in parallel) Option 7 N Standard K-PW15AH - N - M R HBM
6 Subject to modifications. All product descriptions are for general information only. They are not to be understood as a guarantee of quality or durability. measure HBM and predict with confidence 6 Hottinger Baldwin Messtechnik GmbH Im Tiefen See Darmstadt Germany Tel Fax info@hbm.com
Single point load cell
PW15AH Single point load cell Special features - Nominal load 10 kg... 100 kg - Stainless steel - High ratio of minimum verification interval Y - Industrial Footprint (SP4M) - Degree of Protection IP68;
More information100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features
C16A 100/200/400 t Self-centering pendulum lead cells Special features - Self restoring function - Nominal (rated) loads: 100 t, 200t and 400t - Simple installation - Rust resistant materials, laser welded,
More informationPW6C. Single point load cells. Special features. Data sheet
PW6C Single point load cells Special features - Max. capacities: kg... 40 kg - Aluminum - Accuracy class CMR & C6 - Off center load compensated - Shielded connection cable - Different cable lengths and
More informationLoad cell. Special features. Data sheet
Z6R Load cell Special features - Nominal (rated) loads: 20 kg 200 kg - Welded-on robust cover - Load cells made of rust-resistant materials - Easy to clean - Same dimensions like Z6F - Verifiable up to
More informationRSCC. Data Sheet. Load cells. Special features. Diagram of RSCC load cell. Design: 500 kg to 5 t. Design: 50 kg to 200 kg. B
RSCC Load cells Data Sheet Special features - Load cell with SG measurement system - aximum capacities: 50 kg to 5 t - Hermetically sealed (IP68) - Rust resistant materials - Legal for trade to 3000 divisions,
More informationC9C. Force Transducer. Special features. Data sheet
C9C Force Transducer Special features - Compact design compressive force transducer - Accuracy class 0.2 - Nominal (rated) forces 50 N to 50 kn - Configurable with different cable lengths, plug assembly
More informationU9C. Data sheet. Force Transducer. Special features. B en
U9C Force Transducer Data sheet Special features Tensile/compressive force transducer Accuracy class 0.2 Nominal (rated) forces 50 N 50 KN Non-rusting, protection class IP67 Configurable with different
More informationZ6... Data sheet. Load cell. Special features. Dimensions (in mm; 1 mm = inches) B en HBM: public 1
Z6... Load cell ata sheet Special features Welded-on metal bellows (rated) loads: 5 kg 1 t Load cells and installation aids made of rust-resistant materials Verifiable up to 6000 divisions, test report
More informationU2B. Force Transducer. Special features. Data sheet
U2B Force Transducer Special features - Tensile/compressive force transducer - Non rusting, degree of protection IP67 - Can be configured with different cable lengths, plug fitting and TEDS on request
More informationS9M. Force Transducer. Special features. Data sheet
S9 Force Transducer Special features - Tensile/compressive force transducer - ccuracy class 0.02 - Hermetically encapsulated (IP68) - Rust-resistant materials - vailable in different cable lengths and
More informationC10. Data sheet. Force transducer. Special features. B de
C10 Force transducer Data sheet Special features Force transducer for static and dynamic applications Made of non-rusting materials Precise (accuracy class from 0.03) Numerous options (double bridge, TEDS,
More informationU2B. Data sheet. Force Transducer. Special features. B en
U2B Force Transducer Special features Data sheet Tensile/compressive force transducer Non-rusting, degree of protection IP67 Can be configured with different cable lengths, plug fitting and TEDS on request
More informationInductive Standard Displacement Transducers
WA Inductive Standard Displacement Transducers Special features - Available as displacement probe or with detachable plunger - Good thermal stability in the event of temperature gradients - Space saving,
More informationZ6... Data Sheet. Load cell. Special features. Dimensions (in mm; 1 mm = inches) B en 1
Z6... Load cell ata Sheet Special features - Welded on metal bellows - Nominal (rated) loads: 5 kg 1 t - Load cells and installation aids made of rust resistant materials - Verifiable up to 6000 parts,
More informationU10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch]
U10M Force Transducer Special features - Precise and robust tensile/compressive force transducer for static and dynamic measurement tasks - High lateral force and bending moment stability, the effect of
More informationU15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants
U15 Force transducer Special features - Tensile/compressive force transducer - Nominal (rated) forces 2.5 kn to 2.5 MN - lass 0.5 to ISO 376 in force measurement range between 10% and 100% of the nominal
More informationE *) F 15. H 12 h9. 5.5f7 8h6. a./f approx. 0.5mm Free stroke. Displacement. Initial stroke
Displacement probe Plunger WA Inductive Standard Displacement Transducers Special features Displacement probe and transducer with detachable plunger Good thermal stability in the event of temperature gradients
More informationT40FH. Torque flange. Special features. Data sheet
T40FH Torque flange Special features - Nominal (rated) torques: 100kNm, 125kNm, 150kNm, 200kNm, 250kNm, 300kNm - Nominal (rated) rotational speed of 2000 rpm up to 3000 rpm - Compact design - Version for
More informationType PB Load Cell. Approvals OIML approval to C3 (Y = 7 500; Y = for 375 kg capacity)
Type PB Load Cell IP65 Product Description The type PB is a very low profile planar beam load cell. Its unique Flintec design allows for an extremely low scale construction. Using 3 or 4 type PB load cells
More informationT22. Torque transducer. Special features. Data sheet
T22 Torque transducer Special features - Nominal (rated) torques 0.5 Nm, 1 Nm, 2 Nm, 5 Nm, Nm, Nm, 50 Nm, 0 Nm, 0 Nm, 500 Nm and 1 knm - Nominal (rated) rotational speed up to 000 rpm (depending on measuring
More informationData Sheet. Absolute pressure transducer Nominal (rated) pressure 10 bar to 3000 bar. Special features
P3 Top Class P3MB version with fixed cable P3MBP version with plug connection TEDS: Transducer Electronic Data Sheet P3 Absolute pressure transducer Nominal (rated) pressure 10 bar to 3000 bar Special
More informationData sheet. P3 Top Class BlueLine. P3MBP BlueLine. Ultra-high pressure transducers to 15,000 bar. Special features
Ultra-high pressure transducers to 1,000 bar Data sheet Special features P Top Class BlueLine PMBP BlueLine - For static and dynamic pressure variance, pressure peaks and pressure fluctuations - Principle
More informationT40B. Torque Flange. Special features. Data sheet. Overall concept
T40B Torque Flange Special features - Nominal (rated) torques 50 N m, 0 N m, 200 N m, 500 N m, 1 kn m, 2 kn m, 3 kn m, 5 kn m and kn m - Nominal rated rotational speed up to 24000 rpm (depending on nominal
More informationMDEX. on customized sensors. Technical information. Torque transducer. CS-T-04-MDEX Special features
MDEX Torque transducer CS-T-04-MDEX Special features - Explosion proof acc. to ATEX 95 - Exx II 2 G Ex deq IIC T4 - Nominal (rates) torque of 100kNm, 130kNm and 150kNm - HBM Accuracy Class 0,1 - Digital
More informationT40FM. Data Sheet. Torque flange. Special features. Overall concept. B en
T40FM Torque flange Special features Data Sheet - Nominal (rated) torque: 15 kn m, 20 kn m, 25 kn m, 30 kn m, 40 kn m, 50 kn m, 60 kn m, 70 kn m and 80 kn m - Nominal (rated) rotational speed up to 8000
More informationABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS2000S Hermetically sealed bending beam load cell
BB ME SURE ME NT & N L YT ICS D T SHE ET 9QGPS2000S Hermetically sealed bending beam load cell 2 Measurement made easy High-end load cell combining high accuracy with high resistance in harsh environment.
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationOperating manual. Force transducer with strain gage measuring system C9B. A en. hvordan man bruger astrologi med tibetanske medicin
Operating manual Force transducer with strain gage measuring system C9B hvordan man bruger astrologi med tibetanske medicin C9B Contents 3 Page Safety instructions..............................................
More informationSpecifications Type WA2 WA10 WA20 WA50 WA100 WA200 WA300 WA500 Nominal displacement mm Nomi
Displacement probe WA Inductive Standard Displacement Transducers Special features Data Sheet Plunger Displacement probe and transducer with detachable plunger Good thermal stability in the event of temperature
More informationTB2. Torque reference transducer. Special features. Data sheet
T2 Torque reference transducer pecial features tandard version - ccuracy class 0.03 - ominal (rated) s 100 m, 200 m, 500 m, 1 k m, 2 k m, 3 k m, 5 k m and 10 k m - High permissible oscillation width -
More informationMX1615B-R. Ultra-rugged Bridge Amplifier. Special features. Data sheet. Block diagram
MX1615B-R Ultra-rugged Bridge Amplifier Special features - 16 individually configurable inputs - Connection of strain gages in half-, full- or quarter-bridge (120 Ohm or 350 Ohm) - Bridge excitation: DC
More informationMX1615B R. Data Sheet. Ultra-rugged Bridge Amplifier
MX1615B R Ultra-rugged Bridge Amplifier Data Sheet Special features 16 individually configurable inputs Connection of strain gages in quarter-, half- or full-bridge Bridge excitation: DC or carrier frequency
More informationT22. Data Sheet. Torque transducer. Special features. Installation example with two bellows couplings. B en
T22 Torque transducer Data Sheet Special features - Nominal (rated) torques N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m, 00 N m and 1 kn m - Nominal (rated) rotational speeds of 9000 rpm to 16 000 rpm
More informationT10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en
T10FS Torque Flange Data Sheet Special features Nominal (rated) torques: 100 NVm, 200 NVm, 500 NVm, 1 knvm, 2 knvm, 3 knvm, 5 knvm, 10 knvm Nominal speed from 12,000 rpm to 24,000 rpm Low rotor weights
More informationT10F. Data Sheet. Torque Flange. Special features. Installation example T10F. B en
T10F Torque Flange Data Sheet Special features Extremely short design High permissible dynamic loads High permissible transverse forces and bending moments Very high torsional stiffness Contactless Selectable
More informationMX1601B-R. Ultra rugged Standard Amplifier. Data sheet. Special features. Block diagram
MX1601B-R Ultra rugged Standard Amplifier Special features - 16 individually configurable inputs (electrically isolated) - Support of 60 V, 10 V, 100 mv, 20 ma or IEPE on all channels - Sample rate: up
More informationSpecifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0
Digibar II: PE00, PE50 Digital pressure gage Special features Data Sheet PE00 PE50 Operated as manometer with battery operation and Operated as pressure measurement transmitter with 420 current output,
More informationMX840B R. Data sheet. Ultra-rugged universal amplifier CAN. Special features. Block diagram. B en
MX840B R Ultra-rugged universal amplifier Data sheet Special features 8 individually configurable inputs (electrically isolated) Connection of more than 16 technologies per channel Sampling rates of up
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationelectronics Data Sheet Industrial Amplifier Special features Dimensions (in mm; 1 mm= inches) B en
C l i p electronics Industrial Amplifier Data Sheet Special features Amplifier and additional units for strain gauge full bridges and inductive half and full bridges Modules for mounting onto support rails
More informationMX460B-R. Rugged pulse and frequency measuring module. Data sheet. Special features. Block diagram
MX460B-R Rugged pulse and frequency measuring module Special features - Four individually configurable inputs (electrically isolated) - Measure any kind of digital signals up to 1 Mhz for measurement of
More informationMX1601B R. Data Sheet. Ultra-rugged Standard Amplifier
MX1601B R Ultra-rugged Standard Amplifier Data Sheet Special features 16 individually configurable inputs (electrically isolated) Support of 60 V, 10 V, 100 mv, 20 ma or IEPE on all channels Sample rate:
More informationBestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax:
Load Cell F60X Bending beam load cell made of stainless steel, hermetically sealed. Approved up to 6000d R60 OIML. Level of protection IP 68. ATEX 94/9/CE version for hazardous area (option). Designed
More informationBestech Australia U14/44 Garden Blvd, Tel: Dinely VIC 3172 Fax:
Load cell 50... 500 kg High capacity single point load cell made of aluminum. EEC approvals in 3000 d according to OIML R60 and up to 5000 d NTEP. Designed to fit with single point platforms of maximum
More informationDS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor
GmbH Postal address: House address Fon (+49) 0 22 42-870-0 Postbox 26 Löhestr. 7 Fax (+49) 0 22 42-870-20 http: // www.tematec.de 5759 Hennef 577 Hennef e-mail: team@tematec.de Data Sheet Page /5 Intelligent
More informationCANHEAD. Data Sheet. Special features. Distributed measurement acquisition. B en
CANHEAD Data Sheet Special features 10channel amplifier modules for installation close to measuring points Measured data transmission to communication master via field bus Base modules for individual SGs,
More informationBestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax:
Load Cell F60X Bending beam load cell made of stainless steel, hermetically sealed. Approved up to 6000d R60 OIML. Level of protection IP 68. ATEX 94/9/CE version for hazardous area (option). Designed
More informationSUNSTAR 传感与控制
SUNSTAR 传感与控制 http://www.sensor-ic.com/ HBM Mess- und Systemtechnik GmbH Electrical measurement of mechanical quantities Operating manual Force transducer with strain gauge measuring system C9B B 20.C9B.20
More informationMX1615. Data sheet. Bridge/strain gauge amplifier
MX1615 Bridge/strain gauge amplifier Data sheet Special features 16 individually configurable inputs Connection of strain gauges in quarter-, half- and full-bridge Bridge excitation : DC or carrier frequency
More informationPrecision Junction Boxes
Precision Junction Boxes Accuracy and Stability All components are designed for high accuracy and long term stability. Precision SMT resistors and gold plated switches guarantee trouble free operation.
More informationIntrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F
Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE
More informationISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits
ISOBE5600 Isolated Probe Systems - ISOBE5600 Isolation system - ISOBE5600 Transient recorder Data sheet Features and Benefits ISOBE5600 Isolation system - Cost-effective - Fiber-optic isolation - Analogue-in
More informationTechnical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10
Compression force transducer with Thin-film sensor Accuracy: 1 % Output signal: 4...20 ma; 2-wire, 0...10 VDC; 3-wire Optional Optional ATEX/IECEX II 2G Ex ib IIC T4/T3 for SIL3-Applications with 2-channel
More information7600 Isolated Digitizer and Receiver
7600 Isolated Digitizer and Receiver Data sheet GEN series Features and Benefits - Complete single-channel isolated analog input subsystem - Rugged enclosure for use in EMI hostile environments - Shock
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationCondumax W CLS15 and CLS15D
Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationIntrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F
Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE
More informationWeighing Instruments
GHM Messtechnik GmbH Sales Center International Schloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88 www.ghm-messtechnik.de info@ghm-messtechnik.de Weighing Instruments System Evaluation
More informationPrecision Junction Boxes
Precision Junction Boxes Accuracy and Stability All components are designed for high accuracy and long term stability. Precision SMT resistors and gold plated switches guarantee trouble free operation.
More informationWeighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier
GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Weighing System Evaluation Mounting DMS strain gauges (load cells), DMS amplifier
More informationOEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted
Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant
More informationTransducer transmitter BILT 4 II 2(1) G. Technical Manual
GB Transducer transmitter BILT 4 II 2(1) G Technical Manual Transducer transmitter BILT 4 Contents Introduction General... 3 Ex.safety description... 4 Technical data... 5 Installation General... 6 Mechanical
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationSubmersible pressure sensor For oils and fuels Model LF-1
Level measurement Submersible pressure sensor For oils and fuels Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems for oils and fuels Overfilling and dry-run
More informationIntrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H
Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments WIKA Data Sheet PE 81.51 Applications
More informationValve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator
Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator ANSI version Application Control valves designed for mechanical and plant engineering. Suitable for liquids, gases and steam
More informationCable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*
Features Assembly Cable gland series for shielded EMC cables Brass nickel-plated or stainless steel AISI 316 Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex d, Ex e and Ex tb Metric and NPT
More informationCondumax CLS15 and CLS15D
Technical Information Condumax CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationT12. Data sheet. Digital Torque Transducer. Special features. Signal flow block diagram. B en
T12 Digital Torque Transducer Data sheet Special features Nominal (rated) torques 100 N m, 200 N m, 500 N m, 1 kn m, 2 kn m, 3 kn m, 5 kn m and 10 kn m Nominal (rated) rotational speeds from 10 000 rpm
More informationSubmersible pressure sensor For water and wastewater Model LW-1
Replacement product: Model LF-1 Level measurement Submersible pressure sensor For water and wastewater Model LW-1 WIKA data sheet LM 40.03 Applications Level measurement in rivers and lakes Deep well and
More informationFloat Switches with Permanent Magnet For Vertical Installation Model RSM
Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring
More informationIntrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751
Data sheet Intrinsically safe pressure transmitter MBS 420, MBS 425, MBS 470 and MBS 475 The intrinsically safe pressure transmitter program is designed for use in hazardous environments and offers a reliable
More informationMX1616B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram
MX1616B Strain gauge bridge amplifier Special features - 16 individually configurable inputs - Connection of strain gauges in full-, halfand quarter-bridge (350 or 1,000 Ohm) - Bridge excitation : DC or
More informationTerms and expressions for specifying torque transducers
Terms and expressions for specifying torque transducers Terms and expressions for specifying torque transducers Metrological properties of the torque measuring system Accuracy class The accuracy class
More informationInstallation Guide. English. FS62 Embedded Strain Sensor
Installation Guide English FS62 Embedded Strain Sensor Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 D-64239 Darmstadt Tel. +49 6151 803-0 Fax +49 6151 803-9100 info@hbm.com www.hbm.com HBM FiberSensing,
More informationInstallation Guide. English. FS62 Weldable Strain Sensor
Installation Guide English FS62 Weldable Strain Sensor Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 D-64239 Darmstadt Tel. +49 6151 803-0 Fax +49 6151 803-9100 info@hbm.com www.hbm.com HBM FiberSensing,
More informationInstallation Guide. English. FS62 Surface Mountable Strain Sensor
Installation Guide English FS62 Surface Mountable Strain Sensor Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 D-64239 Darmstadt Tel. +49 6151 803-0 Fax +49 6151 803-9100 info@hbm.com www.hbm.com
More informationCondumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.
Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers
More informationMiniature resistance thermometer Explosion-protected version Model TR34, thread-mounted
Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction
More informationA shear beam load cell, with strain gauges, tested as a part of a weighing instrument. Manufacturer : Precia Molen Type : CSI.
Test certificate Page 1 of 4 Issued by Hugo de Grootplein 1 3314 EG Dordrecht The Netherlands Notified Body Number 0122 In accordance with Applicant In respect of Paragraph 8.1 of the European Standard
More informationBenefits/Application. Class 00 according to ISO 376 in the range 10 % to 100 % Especially to trace back Force Standard Machines
Data sheet Force transfer standard Series KTN-Z/D (5 N 1000 kn) Benefits/Application Class 00 according to ISO 376 in the range 10 % to 100 % For static tensile and compressive forces Especially to trace
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high
More informationTemperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.
SENSORS FOR FOOD AND LIFE SCIENCES. Product Information TSM and TSB FOOD Temperature Sensor Application/Specified usage Temperature Measurement in vessels and pipes Authorizations Application examples
More informationResistance Thermometers Model Series TR7X0, Sheathed Design
Electrical Temperature Measurement Resistance Thermometers Model Series TR7X0, Sheathed Design WIKA Data Sheet TE 60.40 Applications T Suitable for all industrial and laboratory applications Special Features
More informationPressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11
Electronic pressure measurement Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11 WIKA data sheet PE 81.27 for further approvals see page
More informationMX440A. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en
MX440A Universal amplifier Data Sheet Special features 4 individually configurable inputs (electrically isolated) Connection of more than 12 transducers technologies Data rate: up to 19,200 Hz 24 bit A/D
More informationPRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS
PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS PRESSURE AT THE HIGHEST LEVEL Successful medium-sized companies are not successful because they are active in many areas, but rather because they
More informationIntrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F
Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F,
More informationSubmersible pressure sensor For superior applications Model LF-1
Level Submersible pressure sensor For superior applications Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems Overfilling and no-load operation monitoring
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationProcess transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm
Electronic pressure measurement Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm WIKA data sheet PE 86.05 Applications Process technology Machine building and plant
More informationIsolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No
9165/16-11-10s 207909 Compact one- and two-channel Ex i output isolating repeater wire-breakage and short-circuit monitoring system, which can be disconnected and features a signalling contact can be used
More informationSMSTRB. Data Sheet. Strain SMART Module. Special Features. Block Diagram. B en
SMSTRB Strain SMART Module Data Sheet Special Features - Conditions and amplifies output to a high level signal for use with the SoMat EHLS or ELHLS - Strain gage conditioning with support for 1/4-, 1/2-
More informationFloat switch For industrial applications, plastic version Model RLS-2000
Level measurement Float switch For industrial applications, plastic version Model RLS-2000 WIKA data sheet LM 50.04 Applications Level measurement of liquids in machine building Control and monitoring
More informationUltra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26
Electronic pressure measurement Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26 WIKA data sheet PE 87.07 Applications Gas panels for OEM tools Semiconductor, flat panel display and
More informationInductive sensor slot-type SI2-K08-AP7
SI2-K08-AP7 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments 3-wire DC, 10 30 VDC NO contact, PNP output Cable connection Wiring diagram Type
More informationMX1601B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en
MX1601B Universal amplifier Data Sheet Special features 16 individually configurable inputs (electrically isolated) Connection of of standard signals (60, 10, 100 m, 20 ma, IEPE) Individual data rates
More informationOperating manual. 600 Hz Measuring Amplifier ME30. A en
Operating manual 600 Hz Measuring Amplifier ME30 ME30 Contents 3 Page Safety instructions............................................. 4 1 Measuring Amplifiers on Eurocards ME30.................... 8
More informationModel 41E. Precision Low Profile Load Cell DESCRIPTION FEATURES
Precision Low Profile Load Cell DESCRIPTION Model 41E is a low profile pancake type load cells. These bonded foil, strain gage load cells are engineered to measure loads from 20 N to 200 kn. The tension/
More informationEBRG. Data Sheet. edaq Bridge Layer. Special Features. Block Diagram. B en
EBRG edaq Bridge Layer Data Sheet Special Features - 16 simultaneously-sampled, low-level differential analog inputs from ±0.000625 to ±10 V - 96 automatic gain states ensuring use of the fullest possible
More information