Single point load cell

Size: px
Start display at page:

Download "Single point load cell"

Transcription

1 PW15AH Single point load cell Special features - Nominal load 10 kg kg - Stainless steel - High ratio of minimum verification interval Y - Industrial Footprint (SP4M) - Degree of Protection IP68; IP69K - Different cable lengths and other options available Data sheet Dimensions (in mm; 1 mm= inches) x0.5 Plug (see page 3) Connection cable (see page 3) (only 1x) 17.5

2 Specifications Type Accuracy class 1) PW15AH/PW15AHY (C3 MR) C3 Multi Range (MR) Max. number of load cell interval n LC 3000 Maximum capacity E max kg Min. LC verification interval v min g Ratio of minimum verification interval (PW15AH) Y Temperature effect on zero balance (PW15AH) TK 0 % of C n / 10 K Ratio of minimum verification interval (PW15AHY) Temperature effect on zero balance (PW15AHY) Y TK 0 % of C n / 10 K Maximum platform size mm 500 x 400 Sensitivity C n mv/v Zero balance Temperature effect on sensitivity 2) Temperature range: C [ F] C [ F] % of C TK n / C 10 K Hysteresis error 2) d hy Non linearity 2) d lin % of C Minimum dead load output return DR n Off center load error 3) ) Input resistance R LC Ω Output resistance R Reference excitation voltage U ref 5 Nom. range of excitation voltage B U V 1... Max. excitation voltage 15 Insulation resistance with 100 V DC R is GΩ > 1 Nominal temperature range B T [ F] Service temperature range B tu C [ F] [ F] Storage temperature range B tl [ F] Safe load limit * ) E L % of E max 150 * ) at max. eccentricity mm 160 Lateral load limit, static E lq % of E max 300 Breaking load E d 300 Deflect. at E max, approx. s nom mm < 0.5 Weight, approx. m kg 1.0 Protection class 5) Material Measuring element Cable sheath IP 68 (test conditions 100 h at 1 m water column); IP69K (water at high pressure, steam jet cleaning) 4) ) PVC 1) According to OIML R60 with P LC = 0.7 2) The data for Non linearity (d lin ), Hysteresis error (d hy ) and Temperature effect on sensitivity (TK C ) are typical values. The sum of these data meets the requirements according to OIML R60. 3) According to OIML R76 4) Following the definitions of the DIN 40050, part of 9, for road vehicles 5) According to EN60529 (IEC529) 6) According to EN HBM 2

3 Wiring code Connection wirh 6 wire cable (selectable cable length: 3 m; 6 m) Detailed description of the Pancon plug (CE100F26-6), 6 pole Shield (yellow) = Shield connected to load cell body Wrap connection 1 (white) = Measurement signal (+) Wrap connection 2 (red) = Measurement signal (-) Wrap connection 3 (black) = Excitation voltage (-) 4 Wrap connection 4 (blue) = Excitation voltage (+) 5 6 Wrap connection 5 (green) = Sense lead (+) Wrap connection 6 (grey) = Sense lead (-) blue marking Cable protection (to be implemented by the customer) Protective cable conduit system*, consisting of: cable gland* cable protection tube* O ring seal (customer side) Unscrew M sleeve and replace with M threaded tube coupling * Supplier, e.g. Comp. Flexicon, UK: sales@flexicon.uk.com Worldwide: export@flexicon.uk.com 3 HBM

4 Load application Load must not be applied to the side where the cable connection is located, as this would cause a force shunt. platform center load application connection cable mounting spacing washer (customer construction) Ordering codes PW15AH (Stainless steel, hermetically sealed) Type PW15AH PW15AHY Accuracy class C3-MR (OIML) (Multi Range) C3-MR (OIML) Comments Capacity 10 kg 20 kg 50 kg 100 kg Cable length 3 m (6-wire)- Order number 1-PW15AHC3/10KG-1 1-PW15AHC3/20KG-1 1-PW15AHC3/50KG-1 1-PW15AHC3/100KG-1 1-PW15AHY/10KG-1 1-PW15AHY/20KG-1 1-PW15AHY/50KG-1 HBM 4

5 PW15AH (Stainless steel, hermetically sealed), optional versions Order no. K PW15AH N Option 1: Mechanical version Standard MR Option 2: Accuracy C3-MR (OIML) Option 3: Capacity kg kg kg kg N AI1/21 AI2/22 Option 4: Explosion protection No explosion protection IECEx+ATEX Zone 1/21+FM, intrinsically safe II2G Ex ia IIC T6/T4 Gb/II2G Ex ia IIIC T5 C Db IECEx+ATEX Zone 2/22, not intrinsically safe II3G Ex na IIC T6/T4 Gc/II3D Ex tc IIIC T5 C Dc Option 5: Cable length 3 3 m 6 6 m N A Option 6: Miscellaneous without 2mV/V ±0.1% / 359 Ohm ±0.3 Ohm (aligned output, suitable for connection in parallel) Option 7 N Standard K-PW15AH - N - M R HBM

6 Subject to modifications. All product descriptions are for general information only. They are not to be understood as a guarantee of quality or durability. measure HBM and predict with confidence 6 Hottinger Baldwin Messtechnik GmbH Im Tiefen See Darmstadt Germany Tel Fax info@hbm.com

Single point load cell

Single point load cell PW15AH Single point load cell Special features - Nominal load 10 kg... 100 kg - Stainless steel - High ratio of minimum verification interval Y - Industrial Footprint (SP4M) - Degree of Protection IP68;

More information

100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features

100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features C16A 100/200/400 t Self-centering pendulum lead cells Special features - Self restoring function - Nominal (rated) loads: 100 t, 200t and 400t - Simple installation - Rust resistant materials, laser welded,

More information

PW6C. Single point load cells. Special features. Data sheet

PW6C. Single point load cells. Special features. Data sheet PW6C Single point load cells Special features - Max. capacities: kg... 40 kg - Aluminum - Accuracy class CMR & C6 - Off center load compensated - Shielded connection cable - Different cable lengths and

More information

Load cell. Special features. Data sheet

Load cell. Special features. Data sheet Z6R Load cell Special features - Nominal (rated) loads: 20 kg 200 kg - Welded-on robust cover - Load cells made of rust-resistant materials - Easy to clean - Same dimensions like Z6F - Verifiable up to

More information

RSCC. Data Sheet. Load cells. Special features. Diagram of RSCC load cell. Design: 500 kg to 5 t. Design: 50 kg to 200 kg. B

RSCC. Data Sheet. Load cells. Special features. Diagram of RSCC load cell. Design: 500 kg to 5 t. Design: 50 kg to 200 kg. B RSCC Load cells Data Sheet Special features - Load cell with SG measurement system - aximum capacities: 50 kg to 5 t - Hermetically sealed (IP68) - Rust resistant materials - Legal for trade to 3000 divisions,

More information

C9C. Force Transducer. Special features. Data sheet

C9C. Force Transducer. Special features. Data sheet C9C Force Transducer Special features - Compact design compressive force transducer - Accuracy class 0.2 - Nominal (rated) forces 50 N to 50 kn - Configurable with different cable lengths, plug assembly

More information

U9C. Data sheet. Force Transducer. Special features. B en

U9C. Data sheet. Force Transducer. Special features. B en U9C Force Transducer Data sheet Special features Tensile/compressive force transducer Accuracy class 0.2 Nominal (rated) forces 50 N 50 KN Non-rusting, protection class IP67 Configurable with different

More information

Z6... Data sheet. Load cell. Special features. Dimensions (in mm; 1 mm = inches) B en HBM: public 1

Z6... Data sheet. Load cell. Special features. Dimensions (in mm; 1 mm = inches) B en HBM: public 1 Z6... Load cell ata sheet Special features Welded-on metal bellows (rated) loads: 5 kg 1 t Load cells and installation aids made of rust-resistant materials Verifiable up to 6000 divisions, test report

More information

U2B. Force Transducer. Special features. Data sheet

U2B. Force Transducer. Special features. Data sheet U2B Force Transducer Special features - Tensile/compressive force transducer - Non rusting, degree of protection IP67 - Can be configured with different cable lengths, plug fitting and TEDS on request

More information

S9M. Force Transducer. Special features. Data sheet

S9M. Force Transducer. Special features. Data sheet S9 Force Transducer Special features - Tensile/compressive force transducer - ccuracy class 0.02 - Hermetically encapsulated (IP68) - Rust-resistant materials - vailable in different cable lengths and

More information

C10. Data sheet. Force transducer. Special features. B de

C10. Data sheet. Force transducer. Special features. B de C10 Force transducer Data sheet Special features Force transducer for static and dynamic applications Made of non-rusting materials Precise (accuracy class from 0.03) Numerous options (double bridge, TEDS,

More information

U2B. Data sheet. Force Transducer. Special features. B en

U2B. Data sheet. Force Transducer. Special features. B en U2B Force Transducer Special features Data sheet Tensile/compressive force transducer Non-rusting, degree of protection IP67 Can be configured with different cable lengths, plug fitting and TEDS on request

More information

Inductive Standard Displacement Transducers

Inductive Standard Displacement Transducers WA Inductive Standard Displacement Transducers Special features - Available as displacement probe or with detachable plunger - Good thermal stability in the event of temperature gradients - Space saving,

More information

Z6... Data Sheet. Load cell. Special features. Dimensions (in mm; 1 mm = inches) B en 1

Z6... Data Sheet. Load cell. Special features. Dimensions (in mm; 1 mm = inches) B en 1 Z6... Load cell ata Sheet Special features - Welded on metal bellows - Nominal (rated) loads: 5 kg 1 t - Load cells and installation aids made of rust resistant materials - Verifiable up to 6000 parts,

More information

U10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch]

U10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch] U10M Force Transducer Special features - Precise and robust tensile/compressive force transducer for static and dynamic measurement tasks - High lateral force and bending moment stability, the effect of

More information

U15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants

U15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants U15 Force transducer Special features - Tensile/compressive force transducer - Nominal (rated) forces 2.5 kn to 2.5 MN - lass 0.5 to ISO 376 in force measurement range between 10% and 100% of the nominal

More information

E *) F 15. H 12 h9. 5.5f7 8h6. a./f approx. 0.5mm Free stroke. Displacement. Initial stroke

E *) F 15. H 12 h9. 5.5f7 8h6. a./f approx. 0.5mm Free stroke. Displacement. Initial stroke Displacement probe Plunger WA Inductive Standard Displacement Transducers Special features Displacement probe and transducer with detachable plunger Good thermal stability in the event of temperature gradients

More information

T40FH. Torque flange. Special features. Data sheet

T40FH. Torque flange. Special features. Data sheet T40FH Torque flange Special features - Nominal (rated) torques: 100kNm, 125kNm, 150kNm, 200kNm, 250kNm, 300kNm - Nominal (rated) rotational speed of 2000 rpm up to 3000 rpm - Compact design - Version for

More information

Type PB Load Cell. Approvals OIML approval to C3 (Y = 7 500; Y = for 375 kg capacity)

Type PB Load Cell. Approvals OIML approval to C3 (Y = 7 500; Y = for 375 kg capacity) Type PB Load Cell IP65 Product Description The type PB is a very low profile planar beam load cell. Its unique Flintec design allows for an extremely low scale construction. Using 3 or 4 type PB load cells

More information

T22. Torque transducer. Special features. Data sheet

T22. Torque transducer. Special features. Data sheet T22 Torque transducer Special features - Nominal (rated) torques 0.5 Nm, 1 Nm, 2 Nm, 5 Nm, Nm, Nm, 50 Nm, 0 Nm, 0 Nm, 500 Nm and 1 knm - Nominal (rated) rotational speed up to 000 rpm (depending on measuring

More information

Data Sheet. Absolute pressure transducer Nominal (rated) pressure 10 bar to 3000 bar. Special features

Data Sheet. Absolute pressure transducer Nominal (rated) pressure 10 bar to 3000 bar. Special features P3 Top Class P3MB version with fixed cable P3MBP version with plug connection TEDS: Transducer Electronic Data Sheet P3 Absolute pressure transducer Nominal (rated) pressure 10 bar to 3000 bar Special

More information

Data sheet. P3 Top Class BlueLine. P3MBP BlueLine. Ultra-high pressure transducers to 15,000 bar. Special features

Data sheet. P3 Top Class BlueLine. P3MBP BlueLine. Ultra-high pressure transducers to 15,000 bar. Special features Ultra-high pressure transducers to 1,000 bar Data sheet Special features P Top Class BlueLine PMBP BlueLine - For static and dynamic pressure variance, pressure peaks and pressure fluctuations - Principle

More information

T40B. Torque Flange. Special features. Data sheet. Overall concept

T40B. Torque Flange. Special features. Data sheet. Overall concept T40B Torque Flange Special features - Nominal (rated) torques 50 N m, 0 N m, 200 N m, 500 N m, 1 kn m, 2 kn m, 3 kn m, 5 kn m and kn m - Nominal rated rotational speed up to 24000 rpm (depending on nominal

More information

MDEX. on customized sensors. Technical information. Torque transducer. CS-T-04-MDEX Special features

MDEX. on customized sensors. Technical information. Torque transducer. CS-T-04-MDEX Special features MDEX Torque transducer CS-T-04-MDEX Special features - Explosion proof acc. to ATEX 95 - Exx II 2 G Ex deq IIC T4 - Nominal (rates) torque of 100kNm, 130kNm and 150kNm - HBM Accuracy Class 0,1 - Digital

More information

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en T40FM Torque flange Special features Data Sheet - Nominal (rated) torque: 15 kn m, 20 kn m, 25 kn m, 30 kn m, 40 kn m, 50 kn m, 60 kn m, 70 kn m and 80 kn m - Nominal (rated) rotational speed up to 8000

More information

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS2000S Hermetically sealed bending beam load cell

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS2000S Hermetically sealed bending beam load cell BB ME SURE ME NT & N L YT ICS D T SHE ET 9QGPS2000S Hermetically sealed bending beam load cell 2 Measurement made easy High-end load cell combining high accuracy with high resistance in harsh environment.

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

Operating manual. Force transducer with strain gage measuring system C9B. A en. hvordan man bruger astrologi med tibetanske medicin

Operating manual. Force transducer with strain gage measuring system C9B. A en. hvordan man bruger astrologi med tibetanske medicin Operating manual Force transducer with strain gage measuring system C9B hvordan man bruger astrologi med tibetanske medicin C9B Contents 3 Page Safety instructions..............................................

More information

Specifications Type WA2 WA10 WA20 WA50 WA100 WA200 WA300 WA500 Nominal displacement mm Nomi

Specifications Type WA2 WA10 WA20 WA50 WA100 WA200 WA300 WA500 Nominal displacement mm Nomi Displacement probe WA Inductive Standard Displacement Transducers Special features Data Sheet Plunger Displacement probe and transducer with detachable plunger Good thermal stability in the event of temperature

More information

TB2. Torque reference transducer. Special features. Data sheet

TB2. Torque reference transducer. Special features. Data sheet T2 Torque reference transducer pecial features tandard version - ccuracy class 0.03 - ominal (rated) s 100 m, 200 m, 500 m, 1 k m, 2 k m, 3 k m, 5 k m and 10 k m - High permissible oscillation width -

More information

MX1615B-R. Ultra-rugged Bridge Amplifier. Special features. Data sheet. Block diagram

MX1615B-R. Ultra-rugged Bridge Amplifier. Special features. Data sheet. Block diagram MX1615B-R Ultra-rugged Bridge Amplifier Special features - 16 individually configurable inputs - Connection of strain gages in half-, full- or quarter-bridge (120 Ohm or 350 Ohm) - Bridge excitation: DC

More information

MX1615B R. Data Sheet. Ultra-rugged Bridge Amplifier

MX1615B R. Data Sheet. Ultra-rugged Bridge Amplifier MX1615B R Ultra-rugged Bridge Amplifier Data Sheet Special features 16 individually configurable inputs Connection of strain gages in quarter-, half- or full-bridge Bridge excitation: DC or carrier frequency

More information

T22. Data Sheet. Torque transducer. Special features. Installation example with two bellows couplings. B en

T22. Data Sheet. Torque transducer. Special features. Installation example with two bellows couplings. B en T22 Torque transducer Data Sheet Special features - Nominal (rated) torques N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m, 00 N m and 1 kn m - Nominal (rated) rotational speeds of 9000 rpm to 16 000 rpm

More information

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en T10FS Torque Flange Data Sheet Special features Nominal (rated) torques: 100 NVm, 200 NVm, 500 NVm, 1 knvm, 2 knvm, 3 knvm, 5 knvm, 10 knvm Nominal speed from 12,000 rpm to 24,000 rpm Low rotor weights

More information

T10F. Data Sheet. Torque Flange. Special features. Installation example T10F. B en

T10F. Data Sheet. Torque Flange. Special features. Installation example T10F. B en T10F Torque Flange Data Sheet Special features Extremely short design High permissible dynamic loads High permissible transverse forces and bending moments Very high torsional stiffness Contactless Selectable

More information

MX1601B-R. Ultra rugged Standard Amplifier. Data sheet. Special features. Block diagram

MX1601B-R. Ultra rugged Standard Amplifier. Data sheet. Special features. Block diagram MX1601B-R Ultra rugged Standard Amplifier Special features - 16 individually configurable inputs (electrically isolated) - Support of 60 V, 10 V, 100 mv, 20 ma or IEPE on all channels - Sample rate: up

More information

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0 Digibar II: PE00, PE50 Digital pressure gage Special features Data Sheet PE00 PE50 Operated as manometer with battery operation and Operated as pressure measurement transmitter with 420 current output,

More information

MX840B R. Data sheet. Ultra-rugged universal amplifier CAN. Special features. Block diagram. B en

MX840B R. Data sheet. Ultra-rugged universal amplifier CAN. Special features. Block diagram. B en MX840B R Ultra-rugged universal amplifier Data sheet Special features 8 individually configurable inputs (electrically isolated) Connection of more than 16 technologies per channel Sampling rates of up

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0) DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

electronics Data Sheet Industrial Amplifier Special features Dimensions (in mm; 1 mm= inches) B en

electronics Data Sheet Industrial Amplifier Special features Dimensions (in mm; 1 mm= inches) B en C l i p electronics Industrial Amplifier Data Sheet Special features Amplifier and additional units for strain gauge full bridges and inductive half and full bridges Modules for mounting onto support rails

More information

MX460B-R. Rugged pulse and frequency measuring module. Data sheet. Special features. Block diagram

MX460B-R. Rugged pulse and frequency measuring module. Data sheet. Special features. Block diagram MX460B-R Rugged pulse and frequency measuring module Special features - Four individually configurable inputs (electrically isolated) - Measure any kind of digital signals up to 1 Mhz for measurement of

More information

MX1601B R. Data Sheet. Ultra-rugged Standard Amplifier

MX1601B R. Data Sheet. Ultra-rugged Standard Amplifier MX1601B R Ultra-rugged Standard Amplifier Data Sheet Special features 16 individually configurable inputs (electrically isolated) Support of 60 V, 10 V, 100 mv, 20 ma or IEPE on all channels Sample rate:

More information

Bestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax:

Bestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax: Load Cell F60X Bending beam load cell made of stainless steel, hermetically sealed. Approved up to 6000d R60 OIML. Level of protection IP 68. ATEX 94/9/CE version for hazardous area (option). Designed

More information

Bestech Australia U14/44 Garden Blvd, Tel: Dinely VIC 3172 Fax:

Bestech Australia U14/44 Garden Blvd, Tel: Dinely VIC 3172 Fax: Load cell 50... 500 kg High capacity single point load cell made of aluminum. EEC approvals in 3000 d according to OIML R60 and up to 5000 d NTEP. Designed to fit with single point platforms of maximum

More information

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor GmbH Postal address: House address Fon (+49) 0 22 42-870-0 Postbox 26 Löhestr. 7 Fax (+49) 0 22 42-870-20 http: // www.tematec.de 5759 Hennef 577 Hennef e-mail: team@tematec.de Data Sheet Page /5 Intelligent

More information

CANHEAD. Data Sheet. Special features. Distributed measurement acquisition. B en

CANHEAD. Data Sheet. Special features. Distributed measurement acquisition. B en CANHEAD Data Sheet Special features 10channel amplifier modules for installation close to measuring points Measured data transmission to communication master via field bus Base modules for individual SGs,

More information

Bestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax:

Bestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax: Load Cell F60X Bending beam load cell made of stainless steel, hermetically sealed. Approved up to 6000d R60 OIML. Level of protection IP 68. ATEX 94/9/CE version for hazardous area (option). Designed

More information

SUNSTAR 传感与控制

SUNSTAR 传感与控制 SUNSTAR 传感与控制 http://www.sensor-ic.com/ HBM Mess- und Systemtechnik GmbH Electrical measurement of mechanical quantities Operating manual Force transducer with strain gauge measuring system C9B B 20.C9B.20

More information

MX1615. Data sheet. Bridge/strain gauge amplifier

MX1615. Data sheet. Bridge/strain gauge amplifier MX1615 Bridge/strain gauge amplifier Data sheet Special features 16 individually configurable inputs Connection of strain gauges in quarter-, half- and full-bridge Bridge excitation : DC or carrier frequency

More information

Precision Junction Boxes

Precision Junction Boxes Precision Junction Boxes Accuracy and Stability All components are designed for high accuracy and long term stability. Precision SMT resistors and gold plated switches guarantee trouble free operation.

More information

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE

More information

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits ISOBE5600 Isolated Probe Systems - ISOBE5600 Isolation system - ISOBE5600 Transient recorder Data sheet Features and Benefits ISOBE5600 Isolation system - Cost-effective - Fiber-optic isolation - Analogue-in

More information

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10 Compression force transducer with Thin-film sensor Accuracy: 1 % Output signal: 4...20 ma; 2-wire, 0...10 VDC; 3-wire Optional Optional ATEX/IECEX II 2G Ex ib IIC T4/T3 for SIL3-Applications with 2-channel

More information

7600 Isolated Digitizer and Receiver

7600 Isolated Digitizer and Receiver 7600 Isolated Digitizer and Receiver Data sheet GEN series Features and Benefits - Complete single-channel isolated analog input subsystem - Rugged enclosure for use in EMI hostile environments - Shock

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Condumax W CLS15 and CLS15D

Condumax W CLS15 and CLS15D Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure

More information

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE

More information

Weighing Instruments

Weighing Instruments GHM Messtechnik GmbH Sales Center International Schloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88 www.ghm-messtechnik.de info@ghm-messtechnik.de Weighing Instruments System Evaluation

More information

Precision Junction Boxes

Precision Junction Boxes Precision Junction Boxes Accuracy and Stability All components are designed for high accuracy and long term stability. Precision SMT resistors and gold plated switches guarantee trouble free operation.

More information

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Weighing System Evaluation Mounting DMS strain gauges (load cells), DMS amplifier

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant

More information

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Transducer transmitter BILT 4 II 2(1) G. Technical Manual GB Transducer transmitter BILT 4 II 2(1) G Technical Manual Transducer transmitter BILT 4 Contents Introduction General... 3 Ex.safety description... 4 Technical data... 5 Installation General... 6 Mechanical

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Submersible pressure sensor For oils and fuels Model LF-1

Submersible pressure sensor For oils and fuels Model LF-1 Level measurement Submersible pressure sensor For oils and fuels Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems for oils and fuels Overfilling and dry-run

More information

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments WIKA Data Sheet PE 81.51 Applications

More information

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator ANSI version Application Control valves designed for mechanical and plant engineering. Suitable for liquids, gases and steam

More information

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.* Features Assembly Cable gland series for shielded EMC cables Brass nickel-plated or stainless steel AISI 316 Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex d, Ex e and Ex tb Metric and NPT

More information

Condumax CLS15 and CLS15D

Condumax CLS15 and CLS15D Technical Information Condumax CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure

More information

T12. Data sheet. Digital Torque Transducer. Special features. Signal flow block diagram. B en

T12. Data sheet. Digital Torque Transducer. Special features. Signal flow block diagram. B en T12 Digital Torque Transducer Data sheet Special features Nominal (rated) torques 100 N m, 200 N m, 500 N m, 1 kn m, 2 kn m, 3 kn m, 5 kn m and 10 kn m Nominal (rated) rotational speeds from 10 000 rpm

More information

Submersible pressure sensor For water and wastewater Model LW-1

Submersible pressure sensor For water and wastewater Model LW-1 Replacement product: Model LF-1 Level measurement Submersible pressure sensor For water and wastewater Model LW-1 WIKA data sheet LM 40.03 Applications Level measurement in rivers and lakes Deep well and

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Data sheet Intrinsically safe pressure transmitter MBS 420, MBS 425, MBS 470 and MBS 475 The intrinsically safe pressure transmitter program is designed for use in hazardous environments and offers a reliable

More information

MX1616B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

MX1616B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram MX1616B Strain gauge bridge amplifier Special features - 16 individually configurable inputs - Connection of strain gauges in full-, halfand quarter-bridge (350 or 1,000 Ohm) - Bridge excitation : DC or

More information

Terms and expressions for specifying torque transducers

Terms and expressions for specifying torque transducers Terms and expressions for specifying torque transducers Terms and expressions for specifying torque transducers Metrological properties of the torque measuring system Accuracy class The accuracy class

More information

Installation Guide. English. FS62 Embedded Strain Sensor

Installation Guide. English. FS62 Embedded Strain Sensor Installation Guide English FS62 Embedded Strain Sensor Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 D-64239 Darmstadt Tel. +49 6151 803-0 Fax +49 6151 803-9100 info@hbm.com www.hbm.com HBM FiberSensing,

More information

Installation Guide. English. FS62 Weldable Strain Sensor

Installation Guide. English. FS62 Weldable Strain Sensor Installation Guide English FS62 Weldable Strain Sensor Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 D-64239 Darmstadt Tel. +49 6151 803-0 Fax +49 6151 803-9100 info@hbm.com www.hbm.com HBM FiberSensing,

More information

Installation Guide. English. FS62 Surface Mountable Strain Sensor

Installation Guide. English. FS62 Surface Mountable Strain Sensor Installation Guide English FS62 Surface Mountable Strain Sensor Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 D-64239 Darmstadt Tel. +49 6151 803-0 Fax +49 6151 803-9100 info@hbm.com www.hbm.com

More information

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0. Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers

More information

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction

More information

A shear beam load cell, with strain gauges, tested as a part of a weighing instrument. Manufacturer : Precia Molen Type : CSI.

A shear beam load cell, with strain gauges, tested as a part of a weighing instrument. Manufacturer : Precia Molen Type : CSI. Test certificate Page 1 of 4 Issued by Hugo de Grootplein 1 3314 EG Dordrecht The Netherlands Notified Body Number 0122 In accordance with Applicant In respect of Paragraph 8.1 of the European Standard

More information

Benefits/Application. Class 00 according to ISO 376 in the range 10 % to 100 % Especially to trace back Force Standard Machines

Benefits/Application. Class 00 according to ISO 376 in the range 10 % to 100 % Especially to trace back Force Standard Machines Data sheet Force transfer standard Series KTN-Z/D (5 N 1000 kn) Benefits/Application Class 00 according to ISO 376 in the range 10 % to 100 % For static tensile and compressive forces Especially to trace

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high

More information

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES. SENSORS FOR FOOD AND LIFE SCIENCES. Product Information TSM and TSB FOOD Temperature Sensor Application/Specified usage Temperature Measurement in vessels and pipes Authorizations Application examples

More information

Resistance Thermometers Model Series TR7X0, Sheathed Design

Resistance Thermometers Model Series TR7X0, Sheathed Design Electrical Temperature Measurement Resistance Thermometers Model Series TR7X0, Sheathed Design WIKA Data Sheet TE 60.40 Applications T Suitable for all industrial and laboratory applications Special Features

More information

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11 Electronic pressure measurement Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11 WIKA data sheet PE 81.27 for further approvals see page

More information

MX440A. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

MX440A. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en MX440A Universal amplifier Data Sheet Special features 4 individually configurable inputs (electrically isolated) Connection of more than 12 transducers technologies Data rate: up to 19,200 Hz 24 bit A/D

More information

PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS

PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS PRESSURE AT THE HIGHEST LEVEL Successful medium-sized companies are not successful because they are active in many areas, but rather because they

More information

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F,

More information

Submersible pressure sensor For superior applications Model LF-1

Submersible pressure sensor For superior applications Model LF-1 Level Submersible pressure sensor For superior applications Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems Overfilling and no-load operation monitoring

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm Electronic pressure measurement Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm WIKA data sheet PE 86.05 Applications Process technology Machine building and plant

More information

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No 9165/16-11-10s 207909 Compact one- and two-channel Ex i output isolating repeater wire-breakage and short-circuit monitoring system, which can be disconnected and features a signalling contact can be used

More information

SMSTRB. Data Sheet. Strain SMART Module. Special Features. Block Diagram. B en

SMSTRB. Data Sheet. Strain SMART Module. Special Features. Block Diagram. B en SMSTRB Strain SMART Module Data Sheet Special Features - Conditions and amplifies output to a high level signal for use with the SoMat EHLS or ELHLS - Strain gage conditioning with support for 1/4-, 1/2-

More information

Float switch For industrial applications, plastic version Model RLS-2000

Float switch For industrial applications, plastic version Model RLS-2000 Level measurement Float switch For industrial applications, plastic version Model RLS-2000 WIKA data sheet LM 50.04 Applications Level measurement of liquids in machine building Control and monitoring

More information

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26 Electronic pressure measurement Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26 WIKA data sheet PE 87.07 Applications Gas panels for OEM tools Semiconductor, flat panel display and

More information

Inductive sensor slot-type SI2-K08-AP7

Inductive sensor slot-type SI2-K08-AP7 SI2-K08-AP7 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments 3-wire DC, 10 30 VDC NO contact, PNP output Cable connection Wiring diagram Type

More information

MX1601B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

MX1601B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en MX1601B Universal amplifier Data Sheet Special features 16 individually configurable inputs (electrically isolated) Connection of of standard signals (60, 10, 100 m, 20 ma, IEPE) Individual data rates

More information

Operating manual. 600 Hz Measuring Amplifier ME30. A en

Operating manual. 600 Hz Measuring Amplifier ME30. A en Operating manual 600 Hz Measuring Amplifier ME30 ME30 Contents 3 Page Safety instructions............................................. 4 1 Measuring Amplifiers on Eurocards ME30.................... 8

More information

Model 41E. Precision Low Profile Load Cell DESCRIPTION FEATURES

Model 41E. Precision Low Profile Load Cell DESCRIPTION FEATURES Precision Low Profile Load Cell DESCRIPTION Model 41E is a low profile pancake type load cells. These bonded foil, strain gage load cells are engineered to measure loads from 20 N to 200 kn. The tension/

More information

EBRG. Data Sheet. edaq Bridge Layer. Special Features. Block Diagram. B en

EBRG. Data Sheet. edaq Bridge Layer. Special Features. Block Diagram. B en EBRG edaq Bridge Layer Data Sheet Special Features - 16 simultaneously-sampled, low-level differential analog inputs from ±0.000625 to ±10 V - 96 automatic gain states ensuring use of the fullest possible

More information