ProHelp Systems MIU 10X/98 WIRING / INSTALLATION INSTRUCTIONS

Size: px
Start display at page:

Download "ProHelp Systems MIU 10X/98 WIRING / INSTALLATION INSTRUCTIONS"

Transcription

1 ProHelp Systems MIU 10X/98 WIRING / INSTALLATI INSTRUCTIS

2 2 MIU-10X /5XS SETUP AND CFIGURATI MIU-10X Configuration and Diagnostics Screen Upon boot-up the MIU-10X first runs a self-diagnosis routine to determine if the keypad, LCD screen, and communications ports are operational. If there are errors during the initialization process, the user is queried if a reinitialization attempt should be performed. If no initialization errors occurred, or if a re-initialization is not requested, the user is next presented the option of viewing a Diagnosis and Configuration mode. To enter the Diagnostic and Configuration mode screen you must press a key when the message PRESS ANY KEY FOR DIAGNOSTICS is being displayed on the LCD s screen. If the prompt to enter the Diagnostics and Configuration screen is missed, it will be necessary to re-power the MIU (Note MIU must be left off for 5-10 seconds) to enter this mode again as the MIU will enter an AWAITING HOST mode. The Diagnostic and Configuration screens allow the user to test the keypad and display, test the UARTs, monitor Host communications, and Gageport baud rates. The system parameters, once set, are stored in battery backed memory and it will not be required to re-enter these unless either the battery is removed or if the MIU s operating characteristics are to be changed. For MIU setup press 7 when main diagnostics menu is displayed. Printer should be left at the default of 0. Gage/Printer also should be left at the default of 0. Jumper Configuration Jumpers JP1 - JP16 Jumpers JP1 through JP15 are provided to allow for single connection of ground references for the digital input signals. Shunt jumper JP1 to connect the ground of Digital Input #1 to the ground of Digital Input #2, shunt jumper JP2 to connect Digital Input #2 s ground to Digital Input # 3, and etc. This sequence continues through Jumper JP15 which connects Digital Input # 15 s ground to Digital Input # 16 s. Jumper JP18 (Default is ) Jumper JP18 (not typically used) connects the ground of Digital Input # 16 to the MIU-10X s digital ground plane itself. If all the digital input signals have a common ground, an installer can use jumpers JP1 through JP16 and JP18 to provide a single ground to all the MIU s digital inputs with a single wire. Jumper JX13 (Default is NC) DO NOT INSTALL SHUNT For External PC Speaker only. Jumper JX2 (Default is Off) - Connects Earth Ground to Internal Ground Jumper JX12A (Default is 2-3) Floppy/Keyboard Enable (Factory Use Only) Jumper JX12B (Default is 1-2) FDRQ/DRQ0 (Factory Use Only) Jumper JX12C (Default is 1-2) FDACK/DACK0 (Factory Use Only) Jumper JP17 (Default is Off) - Provided for end of line termination for MIU communications. Warning!! Only install in last MIU on each channel. Jumper JX7 (Default is Off) Provided to configure COM3 for wire Jumper JX8 (Default is Off) Provided to configure COM3 for wire Jumper JX14A (Default is Off) High speed Analog for IRQ7 Jumper JX14P (Default is Off) Parallel Printer for IRQ7

3 Jumper JX14C (Default is On) Com 4 for IRQ7 Jumper JX3 (Default is 2-3) Com3 / High Speed for IRQ9 Jumper JX6 (Default is Off) - Provided to configure COM4 for wire Jumper JX1 (Default is Off) - Provided to configure COM4 for wire Jumper JX11 (Default is Off) RTS-CTS Connection for Com4 Jumper JA1 thru JA14 (Default is On For Thermocouples only) Provides a ground reference for Thermocouples. JA1=An1, JA2=An2, JA3=An3, JA4=An4, JA5=An5, JA8=An6, JA9=An7, JA10=An8, JA11=An9, JA12=An10, JA13=An11, JA14=An12. Analog Gain Modification The analog SIMs each contain six instrumentation amplifiers, and each of these amps have a fixed 50K input impedance. The gain of an analog channel can be changed by simply replacing the gain resistor, located on the SIMM, (Rg) with a different value. The gain resistor is determined by the formula: Rg = 50000/((10/Vs)-1) -Where Vs is the maximum voltage the sensor will produce. Example: Pressure Transducer rated at 3.0 mv/v 10X excitation voltage of 10 volts Vs=10V x 3.0 mv/v = 30 mv 3

4 MIU 10X/5XS SWITCH SETTINGS OPTI SW ITCHES 1 THRU 8 SW ITCH 3 ( SW 3 ) TIM ED CTACTS M OLD CYC PRESSURE: INJECT LY, 2 TIM E CTACTS BAUD M OLD CYC PRESSURE: INJECT,HOLD,BACK, 4 TIM E CTACTS. GAGE PORT BAUD RATE 1200 BAUD ADDRESS SWITCH 2 ( SW2 ) M OLD CYC PRESSURE: INJECT AND HOLD, 3 TIM E CTACTS BAUD 0 1 BCDEF A = 1st PHYSICAL M IU CHANNEL F = LAST PHYSICAL M IU CHANNEL M OLD CYC PRESSURE: TIM E CTACTS, TURNED BAUD HOST BAUD RATE 4800 BAUD 9600 BAUD 9600 BAUD PRINTING UP = PARALLEL (SHOW N) DOW N = SERIAL 4

5 MIU-10X/5XS - MOTHER BOARD ** DO NOT CNECT AC!!** ** Use supplied +5, -5, DC Power Supply ** ** Components are static sensitive ** ** Do NOT remove battery ** 5

6 MIU-10X/5XS - POWER HOOKUP +12V DC +5V DC -5V DC -12V DC COM M DC POWER SUPPLY EARTH GROUND LY USE SUPPLIED +/-5 AND +/-12 VOLT POWER SUPPLY. 6

7 MIU-10X/5XS - MIU HOST COMMUNICATIS (Black/White pair used) (For Isolation System Only) (DO NOT REMOVE) Belden 8777 To next MIU (Black/Red) (Re d) (Black/Green) (Gree n) (Gree n) (Black/Green) (Re d) (Black/Red) TB1B-1 TB1B-2 TB1B-3 TB1B-4 TB1-4 Tx- TB1-3 Tx+ TB1-2 Rx- TB1-1 Rx+ Rx+ Rx- Tx+ Tx- Belden 8777 From computer or Previous MIU Ground Lug Drain Wires * LOOSEN TERMINAL STRIPS ALL THE WAY (CCW). * STRIP BACK GRAY VINYL JACKETS TO 2.5 INCHES MAXIMUM. * STRIP BACK FOIL SHIELDS TO 2.0 INCHES MAXIMUM. * TAPE EXPOSED SHIELDS ENDS INDIVIDUALLY. * KEEP INDIVIDUAL PAIRS TWISTED TOGETHER. * TWIST SHIELD DRAIN WIRE TOGETHER THE "FROM" CABLE. * CUT SHIELD DRAIN WIRES "TO" CABLE. * STRIP INDIVIDUAL WIRES BACK BETWEEN 3/16 AND 1/4 INCH. * INSERT APPROPRIATE CABLE WIRES INTO INDICATED TERMINALS. * RE-TIGHTEN SCREWS, INSURING INSULATI OF WIRE IS NOT PINCHED IN THE CNECTI. * GENTLY PULL WIRES TO INSURE GOOD ELECTRICAL CNECTI. * LOOSEN CLAMP SCREW GROUND LUG. * PLACE TWISTED SHIELD DRAIN WIRES THROUGH LUG AND SECURE SCREW. 7

8 MIU-10X/5XS - PLC/AIU COMMUNICATIS COM3 - PLC Communications Mode JA7 JB7 JC7 JD7 JE7 JA7 JB7 JC7 JD7 JE7 JA7 JB7 JC7 JD7 JE7 JA7 JB7 JC7 JD7 JE7 JX7 JX8 JX9 JX7 JX8 JX9 JX7 JX7 JX8 JX8 JX9 JX9 RS-485 RS-232 Current Loop RS WIRE COM3 - PLC & AIU Communications TB5-1 TB5-2 TB5-3 TB5-4 RS-232 CTS RTS Rx Tx RS-485 Rx- Rx+ Tx- Tx+ Current Loop Tx+ Tx- Rx+ Rx- RS W IRE NEG ( - ) POS ( + ) SHORT TO TB5-1 SHORT TO TB5-2 TB5-5 Gnd N/A N/A N/A * ENSURE THAT THE EPROM INSTALLED AT U2 COINCIDES WITH THE CTROLLER TO BE CNECTED TO. * FURTHER DETAILS PLC CNECTIS CAN BE FOUND IN THE PLC MANUAL P/N * JUMPERS SUCH AS J9 OR J5 ARE NO LGER NEEDED THE 10X/5XS. COMMUNICATIS FOR REMOTE AIUs (EXTENDED PROCESSES) * SET JA-7 - JE7 FOR RS-485 THE HOST MIU. * CNECT THE PLC PORT, HOST MIU, TO THE HOST COMMUNNICATIS PORT, THE REMOTE AIU. * SUBSEQUENT REMOTE AIUs CNECT HOST PORT TO HOST PORT * USE THE FOLLOWING TABLE FOR WIRING: HOST MIU REMOTE AIU TB1 TB5 R+ T+ R- T- T+ R+ T- R- REMOTE AIU1 TB1 REMOTE AIU2 TB1 T+ T+ T- T- R+ R+ R- R- 8

9 MIU-10X - ANALOG CNECTIS U p p e r Te rm in a ls Lo w e r Te rm in a ls An1 - An1 + An2 - An2 + Analog + Analog - Therm ocouple SIM1-1 SIM1-2 SIM1-3 SIM1-4 SIM1-1 SIM1-2 SIM1-3 SIM1-4 SIM1-5 SIM1-6 SIM1-7 SIM1-8 SIM1-5 SIM1-6 SIM1-7 SIM1-8 An3 - An v Ground An6 - An v Ground Analog + Analog - Ground v P re ssu re Tra n sd u c e r SIM2-1 SIM2-2 SIM2-3 SIM2-4 SIM2-1 SIM2-2 SIM2-3 SIM2-4 An4 - An4 + An5 - An5 + An7 - An7 + An8 - An8 + SIM2-5 SIM2-6 SIM2-7 SIM2-8 SIM2-5 SIM2-6 SIM2-7 SIM2-8 An9 - An v Ground An12 - An v Ground Analog v Ground Analog - Analog + Analog - Rv (*) Lin e a r Potentiom eter Current Source * In se rt e x te rn a l re sisto r R v in te rm in a l p lu g. Rv = 10/(Maxim um input current) An10 - An10 + An11 - An11 + STANDARD CFIGURATI IS An 1-4 AND 7-10 J TYPE THERMOCOUPLE, An 5-6 AND PRESSURE TRANSDUCER. THERMOCOUPLES ARE STANDARD "J" TYPE,"K" TYPE CAN BE USED BY CHANGING GAIN RESISTORS AND SOFTWARE SETUP. LINEAR POTS CAN BE USED BY PULLING OUT THE GAIN RESISTOR THAT CHANNEL (NO GAIN). PRESSURE TRANSDUCER IS BASED 3 mv/v GAIN. DIFFERENT TRANSDUCERS CAN BE USED BY CHANGING GAIN RESISTOR THE SIM FOR THE APPROPRIATE CHANNEL. +10 EXCITATI VOLTAGE 1A MAX FOR ALL DEVICES USING EXCITATI VOLTAGE. REFER TO BELOW CHART FOR INFORMATI GAIN RESISTORS. EACH SIMM HAS 6 ANALOG CAHNNELS. GAIN RESISTOR ARE LOCATED THE SIMM ITSELF (SEE FIGURE 1 SIMM SETUP AND CALIBRATI) CHANNEL 1 = R18 CHANNEL 2 = R15 CHANNEL 3 = R14 CHANNEL 4 = R13 CHANNEL 5 = R22 CHANNEL 6 = R23 J Type TC (std.) K Type TC Common Values 182 Ω 182 Ω 3.0 mv/v (std.) 150 Ω 2.0 mv/v 100 Ω 9

10 MIU 10X ANALOG SIMM SETUP AND CALIBRATI CH1 CH2 CH3 CH4 CH5 CH6 Figure 1 1. J and K type thermocouples both use 182 ohm 1% precision resistor. Prior to calibration allow at least one hour for internal temperature of MIU to stabilize. From the factory each SIM is set up for (4) Thermocouples and (2) Linear devices. The linear is set up for a 3mV/V device. 2. Each channel must have gain and offset set in System Manager MIU (F4, F8, F2) as follows. Gain Offset J or K type Gains must be set as stated prior to calibration. Calibrate by changing offset to match any differences between simulator or press and MIU. Offset is changed in System Manager MIU (F4, F8, F2). Gain resistors and current loop load resistors are located on the SIM. See table below for the designator for each. Current Loop Load Gain Resistor Resistor CH1 R18 CH1 R17 CH2 R15 CH2 R16 CH3 R14 CH3 R19 CH4 R13 CH4 R20 CH5 R22 CH5 R21 CH6 R23 CH6 R24 10

11 MIU 10X/5XS INPUT CTACT WIRING Upper Row Lower Row Cycle Time + Cycle Time - Pulse 2 + Pulse 2 - Pulse 3 + Pulse 3 - Pulse 4 + Pulse IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 IN-16 Aux 1 + Aux 1 - Aux 2 + Aux 2 - Aux 3 + Aux 3 - Aux 4 + Aux 4 - IN-17 IN-18 IN-19 IN-20 IN-21 IN-22 IN-23 IN-24 IN-25 IN-26 IN-27 IN-28 IN-29 IN-30 IN-31 IN-32 Start Stage 1 Start Stage 2 Start Stage 3 End AIU 2 Pulse 2 + AIU 2 Pulse 2 - AIU 2 Pulse 3 + AIU 2 Pulse 3 - AIU 2 Pulse 4 + AIU 2 Pulse 4 - Future Additional Inputs * DIGITAL INPUTS MUST BE 12V TO 50V DC * CTACT WIRE SHOULD BE #18 GA. * CTACTS WITH THE SAME GROUND REFERENCE A SINGLE GROUND WIRE WILL SUFFICE BY THE USE OF JUMPERS JP1-16 AND JP18. (SEE 10X SETUP AND CFIGURATI FOR MORE INFO.) Note: START OF STAGE WILL READ ANALOG CHANNEL 6 LY. 11

12 MIU 10X/5XS OUTPUT CTACT WIRING Upper Row Out-1 Out-2 Out-3 Out-4 Load 0 Load VDC or 120 VAC MAX * OUTPUT CTACTS RATED AT 500 MA MAX. SHOULD A GREATER RATING BE REQUIRED A SECDARY CTACT MUST BE INSTALLED AND THE 10X USED TO SWITCH THAT CTACT. * SECDARY CTACT IS REQUIRED FOR ALL LOADS OVER 450 MA. 12

13 MIU-10X/5XS/0XS/AIU-X/IU-X/MIU-9 EXTERNAL POWER SUPPLY INSTALLATI 1. Mount power supply in the power panel per local codes and regulations. 2. Use supplied mounting brackets. Brackets may be attached to either the back or the side depending on mounting requirements. Only use supplied mounting screws (Maximum mounting screw penetration.38 ). 3. Locate the label above the terminal strip for connection reference. 4. Wire Volts AC to: VAC Power Supply Connection Earth Ground - ACG Line - ACL Neutral - ACN 5. Wire MIU supply voltage as follows: MIU Power Terminal Power Supply Connection TB6-1 - EARTH TB6-2 - COMM COM TB V TB V TB V TB V -5V -12V +12V COM COM +5V N/C ACN ACL ACG 13

14 14

The MP SERIES CONTROLLER. User s Manual. ISE, Inc.

The MP SERIES CONTROLLER. User s Manual. ISE, Inc. The MP SERIES CONTROLLER User s Manual ISE, Inc. 10100 Royalton Rd. Cleveland, OH 44133 USA Tel: (440) 237-3200 Fax: (440) 237-1744 http://variac.com Form No, 003-1622 Rev G 02/25/2009 Form No. 003-1622

More information

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter Model FLSC-C3-XX DC Powered Microprocessor Controlled Transmitter CONTENTS. Introduction----------------------------------------------------------------- 2 2. Specifications ---------------------------------------------------------------

More information

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the

More information

Installation and Operating Manual

Installation and Operating Manual GB Analog Weight Transmitter PS-1000 Installation and Operating Manual LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section

More information

Load Cell Accessories and Services

Load Cell Accessories and Services Load Cell Accessories and Services Highlights Strain gage signal conditioners Cable assemblies Mounting accessories Calibration services PCB Piezotronics, Inc. Toll-Free in USA 888-684-0004 716-684-0001

More information

Data Acquisition Modules/ Distributed IO Modules

Data Acquisition Modules/ Distributed IO Modules User Manual Data Acquisition Modules/ Distributed IO Modules Future Design Controls, Inc. 7524 West 98 th Place / P.O. Box 1196 Bridgeview, IL 60455 888.751.5444 - Office: 888.307.8014 - Fax 866.342.5332

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual NIAGARA M513 Rev. B Model 1005 Pulse to DC Converter Installation, Operation and Maintenance Manual Table of Contents General... 1 Specifications... 1 Installation... 1 Theory of Operation... 2 Setup...

More information

Installation Manual February Model 752E Phase Selector Model 754E Phase Selector Model 760E Card Rack Model 759 Auxiliary Interface Panel

Installation Manual February Model 752E Phase Selector Model 754E Phase Selector Model 760E Card Rack Model 759 Auxiliary Interface Panel Installation Manual February 2008 Opticom Infrared System Model 752E Phase Selector Model 754E Phase Selector Model 760E Card Rack Model 759 Auxiliary Interface Panel Installation i Table of Contents 1

More information

Tel: (949) Fax: (949) IAA100 Product Manual

Tel: (949) Fax: (949) IAA100 Product Manual IAA100 Product Manual Table of Contents Default Settings... 3 Connections... 3 Standard Span & Zero Adjustment... 4 Shunt Readings... 5 Digitally Controlled Remote Shunt... 5 Switch Configurations... 6

More information

CP485-4 User s Manual

CP485-4 User s Manual CP485x4 User s Manual Version 1.0 2005 ZYPEX, Inc. CP485-4 User s Manual Table of Contents Table of Contents Product Description 1 CP485x4 Configuration & Setup 2 Power 2 Baud Rate 2 Control Mode 2 Duplex

More information

Ocean Controls KT-5221 Modbus IO Module

Ocean Controls KT-5221 Modbus IO Module Ocean Controls Modbus IO Module 8 Relay Outputs 4 Opto-Isolated Inputs 2 Analog Inputs (10 bit) 1 PWM Output (10 bit) 4 Input Counters Connections via Pluggable Screw Terminals 0-5V or 0-20mA Analog Inputs,

More information

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA 28231 Ave Crocker Suite 10 Valencia, CA 91355 818-700-8600 Servodynamics.com INFORMATION MANUAL 1525-BRS SERV O D YN A M ICS U SA www.servodynamics.com D y n ad r iv e Bru sh INDEX Page INTRODUCTION 2

More information

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide 14/11/2006 V10 P.O.Box 24 Stanfield 3613 SOUTH AFRICA Tel: +27 (031) 7028033 Fax: +27 (031) 7028041 Email: proconel@proconel.com Web: www.proconel.com

More information

H7625A, H7635A, H7626A, H7636A Series 2000 Humidity/Temperature Sensors

H7625A, H7635A, H7626A, H7636A Series 2000 Humidity/Temperature Sensors H765A, H7635A, H766A, H7636A Series 000 Humidity/Temperature Sensors WALL-MOUNT MODELS APPLICATI The H765A, H766A, H7635A and H7636A Wall-Mount Humidity/Temperature Sensors are universal Relative Humidity

More information

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00 NetBiter I/O Extender 4RO 6RTD 8DIO DAIO User Manual Revision 1.00 IntelliCom Innovation AB Linjegatan 3D SE302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 18 21 99 email info@intellicom.se www

More information

H7625A, H7635A, H7626A, H7636A Series 2000 Humidity/Temperature Sensors

H7625A, H7635A, H7626A, H7636A Series 2000 Humidity/Temperature Sensors H765A, H765A, H766A, H766A Series 000 Humidity/Temperature Sensors WALL-MOUNT MODELS INSTALLATI INSTRUCTIS APPLICATI The H765A, H766A, H765A and H766A Wall-Mount Humidity/Temperature Sensors are universal

More information

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS 815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS USER GUIDE September 2004 Important Notice This document is subject to the following conditions and restrictions: This document contains proprietary information

More information

ZCS485 User s Manual. Version ZYPEX, Inc.

ZCS485 User s Manual. Version ZYPEX, Inc. ZCS485 User s Manual Version 2.2 2004 ZYPEX, Inc. Table of Contents Product Description 1 ZCS485 Configuration & Setup 2 4-wire Operation 2 2-wire Operation 2 Dual Port Operation 2 Carrier Detect 2 Transmitter

More information

Torque Sensor Accessories and Services

Torque Sensor Accessories and Services ------------------- Torque Sensor Accessories and Services Highlights Strain gage signal conditioners Cable assemblies Speed sensors Shunt calibration modules and thermocouples Calibration services PCB

More information

Protection Class (IEC 529)

Protection Class (IEC 529) (W)GS2 Velocity Sensor with Analog or A/D converted synchronous serial output Specifications Velocity Sensor with Position Option Class IP50 Measurement Range: 0... 1500 mm to 0... 2500 mm 0... 59.06 in

More information

Contents. Warranty and Disclaimer 2 Introduction 3

Contents. Warranty and Disclaimer 2 Introduction 3 Contents Warranty and Disclaimer 2 Introduction 3 Physical Dimensions Board Layout 4 Usage Using the Relay board 5 Setting the start address 5 Configuration Jumper 6 Using the Relays 7 Using the DMX connectors

More information

This Errata Sheet contains corrections or changes made after the publication of this manual.

This Errata Sheet contains corrections or changes made after the publication of this manual. Errata Sheet This Errata Sheet contains corrections or changes made after the publication of this manual. Product Family: DL4 Date: September 12, 218 Manual Number D4-ANLG-M Revision and Date th Ed., Rev.

More information

DRG-SC Series Signal Conditioners

DRG-SC Series Signal Conditioners DRG-SC Series Signal Conditioners DRG-SC Series 245 Basic unit Models Available for Thermocouples, RTDs, DC Voltage and Current, Frequency, Strain Gage Bridge, AC Voltage and Current Field Configurable

More information

Product Specification for model TT Transducer Tester Rev. B

Product Specification for model TT Transducer Tester Rev. B TT Rev B April 20, 2010 Product Specification for model TT Transducer Tester Rev. B The Rapid Controls model TT Rev B transducer tester connects to multiple types of transducers and displays position and

More information

There are many important factors when trying to achieve good, reliable communications between 2 devices.

There are many important factors when trying to achieve good, reliable communications between 2 devices. APPLICATION NOTE THIS INFORMATION PROVIDED BY AUTOMATIONDIRECT.COM TECHNICAL SUPPORT These documents are provided by our technical support department to assist others. We do not guarantee that the data

More information

HI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL

HI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL Corporate Headquarters 9440 Carroll Park Drive San Diego, CA 92121 Phone: (858) 278-2900 FAX: (858) 278-6700 Web-Site: http://www.hardysolutions.com

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual TM M723 Rev. C Model 1050 Strain Gage Transmitter Installation, Operation and Maintenance Manual Table of Contents General... 1 Installation... 1 Specifications... 1 Wiring... 2 Setup and Operation...

More information

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide 12/03/2012 V11.0 P.O.Box 164 Seven Hills 1730 NSW AUSTRALIA Tel: +61 2 96248376 Fax: +61 2 9620 8709 Email: proconel@proconel.com Web: www.proconel.com

More information

Economical Digital Indicators For Process and Electrical Measurement

Economical Digital Indicators For Process and Electrical Measurement Economical Digital Indicators For Process and Electrical Measurement DP18 Series Panel Punches Available DP18-P5, 4 to 20 ma input. DP18-EC, thermocouple input visit omega.com/thermocouple for thermocouples.

More information

Series F4P Communications Guide

Series F4P Communications Guide Series F4P Communications Guide 1/4 DIN Temperature/Process Controller with Guided Setup 98 Registered Company Winona, Minnesota USA Watlow Controls 1241 Bundy Blvd., P.O. Box 5580, Winona, Minnesota USA

More information

CSG110 Strain Gauge Universal Amplifier

CSG110 Strain Gauge Universal Amplifier Quick Start Guide CSG110 Strain Gauge Universal Amplifier Sensor Solutions Source Load Torque Pressure Multi-Axis Calibration Instruments Software www.futek.com Getting Help TECHNICAL SUPPORT For more

More information

E297S USER'S GUIDE. Overview. Fast Start. Quantum Research Group Ltd.

E297S USER'S GUIDE. Overview. Fast Start. Quantum Research Group Ltd. Overview Fast Start The E97s board is designed for rapid development and programming of the QTM000 module for capacitancebased sensing systems. It includes all the circuitry required to make a fully functiing

More information

MODEL AT-10 ANALOG TRANSMITTER

MODEL AT-10 ANALOG TRANSMITTER MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca

More information

Model 176 and 178 DC Amplifiers

Model 176 and 178 DC Amplifiers Model 176 and 178 DC mplifiers Features*! Drifts to 100 MΩ! CMR: 120 db @! Gain Linearity of ±.005% *The key features of this amplifier series, listed above, do not necessarily apply

More information

This product is for use in a dry, indoor environment only. This product is not to be installed near water, liquid, or flammable materials.

This product is for use in a dry, indoor environment only. This product is not to be installed near water, liquid, or flammable materials. The equipment described in this manual contains high voltage. Always disconnect power to the equipment before installing, disconnecting, or servicing the product. This product is for use in a dry, indoor

More information

ISOLATED 4-20 ma TRANSMITTERS

ISOLATED 4-20 ma TRANSMITTERS 500 SERIES FOR DEMANDING APPLICATIONS Isolated to 1500 V rms Two-Wire 4-20 ma Operation 9-50 V Compliance Turndown Ratio to 10:1 NMV Protection to 120 Vac -40 to +85 C (-40 to 185 F) Operation Shock Resistance

More information

Microprocessor Control Board Set Up Procedures (OR PLC)

Microprocessor Control Board Set Up Procedures (OR PLC) Microprocessor Control Board Set Up Procedures (OR-00 PLC) SWITCHES/PUSHBUTTONS Push Buttons at display SW Enter button SW Back button SW Down SW UP Back light on/off switch Rotary switches on main board

More information

H7625B, H7626B, H7635B,C H7636B, H7655B, H7656B

H7625B, H7626B, H7635B,C H7636B, H7655B, H7656B H765B, H766B, H7635B,C H7636B, H7655B, H7656B DUCT-MOUNT AND OUTDOOR-MOUNT HUMIDITY/ TEMPERATURE SENSORS INSTALLATI INSTRUCTIS APPLICATI The H76XXB Duct-Mount and H76XXC Outdoor-Mount Humidity/Temperature

More information

5700A/5720A Series II Multi-Function Calibrator

5700A/5720A Series II Multi-Function Calibrator 5700A/5720A Series II Multi-Function Calibrator Operator Guide PN 601648 May 1996 1996 Fluke Corporation, Inc. All rights reserved. Printed in U.S.A. Contents What is in this Guide?... 2 Safety Summary...

More information

Contents. Warranty and Disclaimer 2 Introduction 3

Contents. Warranty and Disclaimer 2 Introduction 3 Contents Warranty and Disclaimer 2 Introduction 3 Physical Dimensions Board Layout 4 Servo connections 5 Using the Serv8 Usage 6 Setting the start address 7 Setting the pulse width 8 Using the configuration

More information

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS INSTALATION, OPERATION & MAINTENANCE MANUAL FOR PA-1001A Series SIGNAL CONDITIONER & CONVERTORS PA1001A 7/02 Page 1 of 11 SIGNAL CONDITIONER & CONVERTERS PA1001A Series INTRODUCTION: The PA1001A series

More information

USING RS-232 to RS-485 CONVERTERS (With RS-232, RS-422 and RS-485 devices)

USING RS-232 to RS-485 CONVERTERS (With RS-232, RS-422 and RS-485 devices) ICS DataCom Application Note USING RS- to RS- CONVERTERS (With RS-, RS- and RS- devices) INTRODUCTION Table RS-/RS- Logic Levels This application note provides information about using ICSDataCom's RS-

More information

24V dc Analog Block I/O Module

24V dc Analog Block I/O Module 24V dc Analog Module Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through the block module. Refer

More information

OPERATION MANUAL LDM-1000

OPERATION MANUAL LDM-1000 OPERATION MANUAL LDM-1000 TE CONNECTIVITY SENSORS /// LDM-1000 OPERATION MANUAL P/N 09290100-000 REV. C 05/2016 Page 1 Table of Contents 1. Introduction...3 2. Product Specifications...3 3. Product Description...4

More information

Blue Point Engineering

Blue Point Engineering DMX Data Analyzer Board nstruction Overview DMX Analyzer - Tester PC Board Design your own enclosure with an analyzer / tester display or add to your existing equipment or system. The DMX Analyzer is a

More information

Applications. Operating Modes. Description. Part Number Description Package. Many to one. One to one Broadcast One to many

Applications. Operating Modes. Description. Part Number Description Package. Many to one. One to one Broadcast One to many RXQ2 - XXX GFSK MULTICHANNEL RADIO TRANSCEIVER Intelligent modem Transceiver Data Rates to 100 kbps Selectable Narrowband Channels Crystal controlled design Supply Voltage 3.3V Serial Data Interface with

More information

SKJ. J1939 CANBus Output Signal. Linear Position to 400 inches (10 m) Compact Design Simple To Install User Adjustable Measuring Cable Orientation

SKJ. J1939 CANBus Output Signal. Linear Position to 400 inches (10 m) Compact Design Simple To Install User Adjustable Measuring Cable Orientation SKJ J939 CANBus Output Signal Linear Positi to 4 inches ( m) Compact Design Simple To Install User Adjustable Measuring Cable Orientati SPECIFICATIONS Stroke Range Optis 25 inches (6.4 m), 4 inches (.2

More information

Ultrasonic Multiplexer OPMUX v12.0

Ultrasonic Multiplexer OPMUX v12.0 Przedsiębiorstwo Badawczo-Produkcyjne OPTEL Sp. z o.o. ul. Morelowskiego 30 PL-52-429 Wrocław tel.: +48 (071) 329 68 54 fax.: +48 (071) 329 68 52 e-mail: optel@optel.pl www.optel.eu Ultrasonic Multiplexer

More information

Single Channel Loop Detector

Single Channel Loop Detector Single Channel Loop Detector Model LD120T Series The LD120T is a series of single channel inductive loop detectors. The use of microprocessor and surface mount technology enables a large number of functions

More information

FastLink TM. Network. Operation and Installation Manual

FastLink TM. Network. Operation and Installation Manual FastLink TM Network Operation and Installation Manual C6570 C6571 C6571S C6572 C6572S C6573S Store and Forward Controller Network Store and Forward Controller Service Store and Forward Controller Network

More information

Installation Manual Rev F MultiProx Controller A

Installation Manual Rev F MultiProx Controller A Installation Manual - 000-900 Rev F MultiProx Controller - 000A Web page, E-mail - www.prox.com - MultiProx Controller Installation Manual 000-900 Rev F of Table of Contents MultiProx System Overview...

More information

269 Troubleshooting Guide 11/4/98 1

269 Troubleshooting Guide 11/4/98 1 269 Troubleshooting Guide 11/4/98 1 Table of Contents Phase currents 3 Communications. 6 RTDs.. 9 Ground Fault Currents... 13 Output Relays. 15 Analog Output 17 Switch Inputs...18 11/4/98 2 Phase Currents

More information

W(G)S3.1 Position Sensor with Analog or A/D converted synchronous serial output

W(G)S3.1 Position Sensor with Analog or A/D converted synchronous serial output W(G)S3.1 Position Sensor with Analog or A/D converted synchronous serial output Position and Velocity Sensor for Long Ranges Protection Class IP50 Measurement Range: 0... 10000 mm to 0... 15000 mm 0...

More information

ARD154. DIN rail mountable amplifier for strain gage sensors. User s guide. User s guide ARD CONNECTING 4-WIRE SENSORS

ARD154. DIN rail mountable amplifier for strain gage sensors. User s guide. User s guide ARD CONNECTING 4-WIRE SENSORS 6. CONNECTING 4-WIRE SENSORS Connections : S+ connected to module A+ S- connected to module A- Shield connected to A- or to GND of analog output Nota: A- and GND are connected together inside the module.

More information

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section 2, Calibration Calculations... 7 Calibration Procedure... 8 Section

More information

PEOPLE IN CONTROL OF MOTION

PEOPLE IN CONTROL OF MOTION MODEL 796500 RESOLVER TO ENCODER CONVERTER FOR MACHINE TOOL, POSITIONING, AND TRANSFER LINE APPLICATIONS *** APPLICATIONS *** Ideal For Closed Loop Positioning Systems Machine Tools Nuclear Applications

More information

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224 T and T+ are trade names of Trol Systems Inc. TSI reserves the right to make changes to the information contained in this manual without notice. publication /4A115MAN- rev:1 2001 TSI All rights reserved

More information

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 ES-Key 12 PDM module (4 selectable polarity outputs) with 4 Inputs (selectable polarity) and 4 MFI Inputs P/N 610-00035 PAGE

More information

OVEN INDUSTRIES, INC. Model 5C7-362

OVEN INDUSTRIES, INC. Model 5C7-362 OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-362 THERMOELECTRIC MODULE TEMPERATURE CONTROLLER TABLE OF CONTENTS Features... 1 Description... 2 Block Diagram... 3 RS232 Communications Connections...

More information

5700A/5720A. Operator Guide. Series II Multi-Function Calibrator

5700A/5720A. Operator Guide. Series II Multi-Function Calibrator 5700A/5720A Series II Multi-Function Calibrator Operator Guide PN 3474006 May 1996, Rev. 1, 5/09 2009 Fluke Corporation. All rights reserved. Printed in USA. All product names are trademarks of their respective

More information

AD-8100 & AD-8200 Servo Amplifiers

AD-8100 & AD-8200 Servo Amplifiers Instruction Manual IM-0607 AD-8100 & AD-8200 Servo Amplifiers Table of Contents General Information... 2 Basic Models... 3 Specifications... 3 Installation Wiring... 3 Setup & Calibration... 4-6 Troubleshooting

More information

+GF+ SIGNET Temperature Transmitter Instructions

+GF+ SIGNET Temperature Transmitter Instructions GF SIGNET 80- Temperature Transmitter Instructions ENGLISH -80.090- B-/00 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal

More information

TO BE DISCONTINUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-F

TO BE DISCONTINUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-F TO BE DISCONTINUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-F NEW Signal Powered or 5-28VDC Powered FLAT PACK PANEL METERS NEED NO PANEL CUT OUT > 40 INPUT SIGNALS ACCEPTED MODEL FPM FEATURES: 4

More information

Hardware Adjustment 13 Trimpots 13 CAL/NORM, CAL1/RUN, and CAL2/RUN Switches 13

Hardware Adjustment 13 Trimpots 13 CAL/NORM, CAL1/RUN, and CAL2/RUN Switches 13 DBK43A and DBK43B 8-Channel Strain Gage Modules Overview 1 Hardware Connection 3 Power Connection 3 Signal Connection 3 Hardware Configuration 4 Bridge Applications 5 AC Coupling and Low-Pass Filter Options

More information

AUTOMATIC TRI-COLOR ISOLATED TRIPLE BAR-DIGITAL CONTROLLER WITH USB/232/485/ETHERNET I/O & MICRO CARD FOR NUCLEAR, MIL-STD & INDUSTRIAL USE

AUTOMATIC TRI-COLOR ISOLATED TRIPLE BAR-DIGITAL CONTROLLER WITH USB/232/485/ETHERNET I/O & MICRO CARD FOR NUCLEAR, MIL-STD & INDUSTRIAL USE NEW! PRELIMINARY AUTOMATIC TRI-COLOR ISOLATED TRIPLE BAR-DIGITAL CONTROLLER WITH USB//85/ETHERNET I/O & MICRO CARD FOR NUCLEAR, MIL-STD & INDUSTRIAL USE MODEL TBD FEATURES: * Ea. isolated bit A/D with

More information

FC Series Signal Conditioners

FC Series Signal Conditioners FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between

More information

IOM. Model 1050 Strain Gage Transmitter Installation & Operation Manual. (Cage Code #1MU21)

IOM. Model 1050 Strain Gage Transmitter Installation & Operation Manual. (Cage Code #1MU21) IOM Model 1050 Strain Gage Transmitter Installation & Operation Manual (Cage Code #1MU21) Model 1050 Strain Gage Transmitter Installation & Operation Manual CONTENTS I. GENERAL...1 II. INSTALLATION...2

More information

Line-to-line RMS Volts, 3 phases 4 digits (XXX.X) Volts

Line-to-line RMS Volts, 3 phases 4 digits (XXX.X) Volts digital ac POWER MONITOR DESCRIPTION The DSP is a three-phase, three-element multifunction digital transducer with outputs for voltage, current, and power via serial communication. Applications include

More information

VXI-TB CHANNEL ISOTHERMAL TERMINAL BLOCK

VXI-TB CHANNEL ISOTHERMAL TERMINAL BLOCK VXI-TB-1303 32-CHANNEL ISOTHERMAL TERMINAL BLOCK Introduction This guide describes how to install and use the VXI-TB-1303 terminal block with a VXI-SC submodule. The VXI-TB-1303 terminal block is a shielded

More information

Model A. DIN Rail Strain Gage Conditioner. Installation and Operating Manual

Model A. DIN Rail Strain Gage Conditioner. Installation and Operating Manual Model 8161-011A DIN Rail Strain Gage Conditioner Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-828-8840 24-hour SensorLine:

More information

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL Roline L1 Series Humidity - Temperature Transmitters INSTRUCTION MANUAL 20030314 CONTENTS Overview... 3 Operation... 5 Power supply... 5 Operating range and limits... 5 Temperature compensation of the

More information

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER OPERATOR S MANUAL DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Web Site: www..com

More information

DEC-001 Installation Instructions

DEC-001 Installation Instructions DEC-001 Installation Instructions Skill Level: The installation of this assembly requires a medium level of expertise in working with modern electronic equipment. The use of appropriate tools, correct

More information

Concept of Serial Communication

Concept of Serial Communication Concept of Serial Communication Agenda Serial v.s. Parallel Simplex, Half Duplex, Full Duplex Communication RS-485 Advantage over RS-232 Serial v.s. Parallel Application: How to Measure the temperature

More information

DESIGN GUIDE FOR INFINITY SYSTEMS

DESIGN GUIDE FOR INFINITY SYSTEMS Doc. 6001114 Rev B DESIGN GUIDE FOR INFINITY SYSTEMS WITH STAND ALONE OR MULTI-LINK FIRMWARE TABLE OF CONTENTS 1. CABINET DIMENSIONS...1 2. WIRE CHART...1 A. CABLING TO THE MAIN PROCESSOR BOARD... 1 B.

More information

CUSTOM RANGE MODULE FOR THE SMART II

CUSTOM RANGE MODULE FOR THE SMART II CUSTOM RANGE MODULE FOR THE SMART II FEATURES 100% Staefa Smart II compatible Factory can customize for most applications Over a hundred different temperature and ranges are available Provides pull-up

More information

HD 48V01T... HD 4977T...

HD 48V01T... HD 4977T... RH-26 HD 4807T HD 4907T HD 48V07T HD 4901T... HD 4801T... HD 4917T... HD 48V01T... HD 4977T... HD 4817T... HD 48V17T... HD 4877T... HD 48V77T... HD 4807T, HD 48V07T, HD 48S07T, HD 4801T..., HD 48V01T...,

More information

Model VJCE-01A VJ Mounting Base for Communication

Model VJCE-01A VJ Mounting Base for Communication User s Manual IM 77J01C51-11E Model VJCE-01A VJ Mounting Base for Communication Please read through this manual as well as the manual for respective instruments of JUXTA VJ series mounted on the VJ mounting

More information

EVDP610 IXDP610 Digital PWM Controller IC Evaluation Board

EVDP610 IXDP610 Digital PWM Controller IC Evaluation Board IXDP610 Digital PWM Controller IC Evaluation Board General Description The IXDP610 Digital Pulse Width Modulator (DPWM) is a programmable CMOS LSI device, which accepts digital pulse width data from a

More information

8 Input/8 Output AC Block I/O Module

8 Input/8 Output AC Block I/O Module 8 Input/8 Output AC Module Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through the block module.

More information

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors. SilverMax Datasheet NEMA 23 Servomotors QuickSilver Controls, Inc. www.quicksilvercontrols.com SilverMax Datasheet - NEMA 23 Servomotors 23 Frame Sizes: 23-3, 23-5, 23H-1, 23H-3, 23H-5 / Series: E, E3,

More information

RR Series TM USER GUIDE. For Vinyl Express R Series Cutters

RR Series TM USER GUIDE. For Vinyl Express R Series Cutters RR Series TM USER GUIDE For Vinyl Express R Series Cutters Thank you for choosing an R Series cutter from SignWarehouse, Inc. Before using your cutter, we suggest you read this guide. It will guide you

More information

LBI Installation & Operation

LBI Installation & Operation Installation & Operation EDACS Power Monitor Unit ericssonz CONTENTS TABLE OF CONTENTS Page INTRODUCTION... 6 DESCRIPTION... 6 APPLICATION NOTES... 7 VAX SITE CONTROLLER COMPUTER... 7 APPLICATION SOFTWARE

More information

F4-08RTD 8-Channel RTD Input

F4-08RTD 8-Channel RTD Input F-8RTD 8-Channel RTD 92 F8RTD 8-Channel RTD Module Specifications The F8RTD 8 Differential Channel RTD module provides several features and benefits. It provides eight RTD input channels with 16-bit resolution.

More information

Generator Paralleling Controller, GPC-3 TCM-2 replacement Paralleling and Protection Unit, PPU-3

Generator Paralleling Controller, GPC-3 TCM-2 replacement Paralleling and Protection Unit, PPU-3 QUICK START GUIDE QUICK START GUIDE Generator Paralleling Controller, GPC-3 Generator Protection TCM-2 replacement Unit, GPU-3/GPU-3 guide Hydro Paralleling and Protection Unit, PPU-3 What s in the delivery?

More information

Bridge Measurement Systems

Bridge Measurement Systems Section 5 Outline Introduction to Bridge Sensors Circuits for Bridge Sensors A real design: the ADS1232REF The ADS1232REF Firmware This presentation gives an overview of data acquisition for bridge sensors.

More information

Vector Frequency Inverter PRODUCT ORIENTATION

Vector Frequency Inverter PRODUCT ORIENTATION PI8600 Series Vector Frequency Inverter PRODUCT ORIENTTION PI8600 series frequency inverter is produced by POWTRN Technology based on PI8100 series highperformance current vector software platform. It

More information

IAA100/IAA200 Analog Amplifiers Voltage/Current

IAA100/IAA200 Analog Amplifiers Voltage/Current Quick Start Guide IAA100/IAA200 Analog Amplifiers Voltage/Current Sensor Solutions Source Load Torque Pressure Multi-Axis Calibration Instruments Software www.futek.com Getting Help TECHNICAL SUPPORT For

More information

4-20mA, 0-10V and general process measuring bargraph displays

4-20mA, 0-10V and general process measuring bargraph displays Page 1 of 6 Digital panel meters Large displays Bargraphs Transmitters 4-20mA, 0-10V process input bargraph displays Display almost any physical variable... The bargraph displays on this page accept most

More information

Mastr III P25 Base Station Transmitter Tune-up Procedure

Mastr III P25 Base Station Transmitter Tune-up Procedure Mastr III P25 Base Station Transmitter Tune-up Procedure 1. Overview The Mastr III Base Station transmitter alignment is performed in several steps. First, the Transmit Synthesizer module is aligned to

More information

Brushed DC Motor Control. Module with CAN (MDL-BDC24)

Brushed DC Motor Control. Module with CAN (MDL-BDC24) Stellaris Brushed DC Motor Control Module with CAN (MDL-BDC24) Ordering Information Product No. MDL-BDC24 RDK-BDC24 Description Stellaris Brushed DC Motor Control Module with CAN (MDL-BDC24) for Single-Unit

More information

The Harvard Research Carrier Signal Conditioner User s Manual

The Harvard Research Carrier Signal Conditioner User s Manual The Harvard Research Carrier Signal Conditioner User s Manual TABLE OF CONTENTS SECTION TITLE PAGE I GENERAL INFORMATION INTRODUCTION 1.1 SPECIFICATIONS 1.1 II INSTALLATION 2.1 GENERAL 2.1 2.2 INITIAL

More information

TO BE DISCONTINUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-D. D. C. SIGNAL POWERED FOR V, 4-20 & madc

TO BE DISCONTINUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-D. D. C. SIGNAL POWERED FOR V, 4-20 & madc TO BE DISCONTUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-D NEW D. C. SIGNAL POWERED FOR V, 4-20 & madc (& EXTERNALLY POWERED FOR OTHER SIGNALS) 3 1/2" ANALOG METER REPLACEMENT *>20 Signal Conditioners

More information

Earth Leakage Monitoring System IsoBase IsoHub IsoOut

Earth Leakage Monitoring System IsoBase IsoHub IsoOut 2014 11 21 Earth Leakage Monitoring System IsoBase IsoHub IsoOut User Manual Due to our policy of continual improvement, specifications may change without prior notice Page 2 (34) Contents Earth Leakage

More information

FC-33, DC SELECTABLE SIGNAL CONDITIONER

FC-33, DC SELECTABLE SIGNAL CONDITIONER FC-33, DC SELECTABLE SIGNAL CONDITIONER Description. The FC-33 is a DIN rail or side mount, selectable input/output signal conditioner with 1500VDC isolation between input and output, and 1500VDC isolation

More information

Integrity Instruments

Integrity Instruments Integrity Instruments XP-A/I User Manual Integrity Instruments P.O. Box Order Phone 00-0-00 Pine River Minnesota Fax Phone -- USA Tech Phone --0 http://www.integrityusa.com XP-A ISOLATED XP-I RS- to RS-

More information

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire POSICHRON Position Sensor Stick Design with Analog Specifications POSICHRON position sensor in stick design Protection class IP67 Measurement range 0... 100 up to 0... 5750 mm Absolute position measurement

More information

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS INSTRUCTIONS MANUAL IM831-U v0.92 HRI-R40W sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS INDEX: GENERAL TYPES ACESSORIES AND OPTIONS

More information

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents KENCO ENGINEERING COMPANY P.O. BOX 470426, TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 http://www.kenco-eng.com e-mail: info@kenco-eng.com KENCO Loop Powered Magnetostrictive Transmitter

More information

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER DESCRIPTION The UltraFlo UFDD Clamp-On Ultrasonic Flow Meter is the ideal flow meter with accurate, easy-to-use, easy-to-install digital doppler technology.