Development and application of a neutron sensor for singleevent effects analysis
|
|
- Garey Sullivan
- 5 years ago
- Views:
Transcription
1 Institute of Physics Publishing Journal of Physics: Conference Series 15 (2005) doi: / /15/1/029 Sensors & their Applications XIII Development and application of a neutron sensor for singleevent effects analysis S P Platt, B Cassels and Z Torok Department of Technology, University of Central Lancashire, Preston, Lancashire. PR1 2HE spplatt@uclan.ac.uk Abstract. The development and application of a charge-coupled device (CCD) sensor for neutron detection is described. The sensor provides images of neutron-induced single-event effects (SEEs) at 9 µm pixel resolution and a charge/pixel resolution of typically 36.6 electronic charges. Example results are presented, showing the charge profiles resulting from single events observed during tests in a representative neutron spectrum. The sensor enables aspects of SEE phenomena to be studied directly in more detail than hitherto. 1. Single event effects in electronics Interactions between semiconductor electronic devices and energetic subatomic particles, such as neutrons, can adversely affect device performance in several ways. In particular, interaction with individual particles can disrupt the function of a device through spurious charge generation, sometimes also leading to permanent failure through a range of indirect mechanisms including latch-up. These effects are termed single event effects (SEEs) as each results stochastically from a single interaction between a device and an ionising particle, rather than occurring as the cumulative effect of many interactions [1]. Neutrons, although not directly ionising, induce SEEs through nuclear interactions with constituent ions of the semiconductor lattice. Technology trends in electronic systems and components are leading to greater susceptibility to single event effects [2]. Smaller device structures, lower operating voltages, and higher clock speeds result in a greater likelihood of device disruption by SEEs, especially in environments where the radiation environment is hostile. One such environment is the atmosphere at altitude, where a damaging neutron flux, arising from the effects of cosmic radiation, is found [3]. As a result, neutroninduced SEEs are of particular concern in avionic applications [4]. To ensure reliability, ground testing of avionic components is routinely undertaken at neutron test facilities such as the Tri- University Meson Facility (TRIUMF), located at the University of British Columbia, Vancouver [5]. This facility provides a simulation of the atmospheric neutron spectrum with neutron flux approximately six orders of magnitude greater than that present at 40,000 ft, providing for accelerated testing of components. This paper describes development of an imaging neutron sensor using a charge-coupled device (CCD), and its use in detecting and analyzing SEEs occurring in the simulated atmospheric spectrum at TRIUMF. The sensor can be used to identify the characteristics of individual neutron interactions and is being used to predict the statistics of neutron-induced SEEs IOP Publishing Ltd 172
2 CCDs as neutron sensors CCDs have several benefits as neutron sensors for SEE detection and analysis: Silicon material. The mechanisms by which charge is generated through neutron interactions with CCDs are the same as those which occur in electronic devices of interest, because of the common underlying physical structure of the silicon lattice. CCDs are therefore a good test bed for the analysis of these effects. Spatial resolution. As imaging devices, CCDs provide information about the spatial distribution of charge generated by SEEs. This is increasingly important, for example in the analysis of multiple bit upsets (MBUs), as device sizes shrink and it becomes possible for a single event to affect more than one device in the same substrate. Charge resolution. CCDs are able simultaneously to provide high spatial and intensity (charge) resolution, thereby accurately determining the density of charge generated in a region of a semiconductor device. 3. Neutron sensor development and operation Our neutron sensor uses a Kodak KAF-0402E CCD. This is a two-phase full frame imaging CCD with 9 µm square pixels [6]. We believe that our results provide neutron SEE images with the finest resolution available to date. Table 1 lists the sensor s principal performance parameters. Sensitivity can be traded off against dynamic range by adjusting analogue-digital converter (ADC) gain; typical operating parameters provide a sensitivity of 36.6 e /ADC count and a maximum signal limited by the pixel well capacity, approximately 100 ke /pixel for the KAF-0402E. Table 1. Neutron sensor performance Pixel size 9 9 µm Rows 512 Columns 768 Area 0.32 cm 2 Sensitivity e /ADC count ADC resolution 12 bit Maximum signal 46 ke /pixel (minimum) The general arrangement of the neutron sensor is illustrated by figure 1. Our equipment comprises an in-beam equipment (IBE), consisting of the CCD and some support electronics, and an out-of-beam equipment (OBE), providing CCD control, analogue signal processing and a frame-grabber interface. The IBE and OBE are connected by an umbilical cable providing power and timing signals to the IBE from the OBE, and transmitting CCD video output from the IBE to the OBE. The equipment is operated under PC control; frames are captured continuously and stored in portable network graphics (PNG) format. A typical frame rate is 2 s 1. We operate our CCD at a 5 MHz pixel frequency. Low-voltage digital signalling (LVDS) is used for the CCD clock transmission. The IBE incorporates LVDS receivers and additional circuits to reconstitute correct CCD clock levels, along with an active load for the CCD and a driver for the video output. Care was taken in laying out the IBE to minimise the neutron fluence received by the support electronics, to minimise the risk of false alarms due to spurious SEE events in those components. The IBE layout took advantage of the tight footprint (approximately 5 12 cm) of the TRIUMF neutron beam, as shown in figure 2. The CCD and support electronics (LVDS receivers, CCD clock drivers, and video amplifier) were mounted on a standard eurocard-size PCB, fully enclosed so as to exclude light. During the trials the IBE package was lowered into the neutron beam from above. The CCD sensor was positioned at the bottom of the IBE board, whereas the support electronics were positioned at the top of the board, as shown, to minimise these components exposure to radiation. Only passive components predominantly decoupling capacitors were permitted in the region between the CCD and the support electronics. Passive components are generally robust to neutron radiation.
3 174 This layout also enabled a soak test to be performed in which the IBE was lowered further into the beam, so that the control electronics were irradiated directly. No false alarms attributable to SEEs in the support electronics were observed over a period of 1.5 hours, confirming the robustness of the devices selected to neutron irradiation and permitting IBE layout constraints to be eased for future designs. PC In-beam area 10 m Out-of beam area IBE CCD control signals 5 MHz video OBE 12-bit video Control parameters Frame grabber Figure 1. Neutron sensor schematic arrangement. Support electronics Beam footprint: soak test CCD Beam footprint: CCD irradiation Figure 2. In-beam equipment layout. 4. Example neutron interaction results Figure 3(a) shows an example frame captured during trials at the TRIUMF Neutron Irradiation Facility. Typically, around 1 in 3,000 neutrons is found to cause events exceeding a pixel threshold level of 20 ke (40 µc.m 2 ). There are around 300 such events in the frame shown in this figure. Figure 3(b) shows a magnified image of a portion of the same frame, showing several neutron interactions in more detail and showing the improvement achieved with this 9 µm sensor over that possible in earlier work [7], which used a 22 µm sensor. This improved resolution is important not only to permit multiple SEEs in the same image to be resolved, but also to define the spatial extent of neutron-induced charge. This is expected to be important, for example, in predicting MBU rates [8].
4 175 (a) (b) Figure 3. A typical neutron SEE image: (a) full frame; (b) detail. An example of the type of detailed information available from the sensor is shown in figure 4. Here, a neutron has struck a silicon ion in a pixel near the left of the figure, causing a nuclear reaction the products of which are an aluminium ion and a 4 MeV proton. By chance the proton travels approximately in the plane of the CCD, clearly showing the rate of charge generation along its path (to the right as shown), terminating in a characteristic Bragg peak. This is illustrated further in figure 5, where the x-axis represents distance along the proton path from the point of neutron impact. The proton travels approximately 100 µm; in contrast, the more massive aluminium ion travels a very short distance, generating all of its charge very close to the point of impact. This causes saturation of the pixel signal at this point, leading to blooming along the CCD column, visible in figure 4. Although blooming reduces the resolution of the SEE image along the column, the total charge generated can still be determined. The total charge associated with this event is 0.5 pc, sufficient to cause an upset in many electronic devices. Figure 4. Example SEE interaction showing a neutron strike releasing a 4 MeV proton. Figure 5. SEE charge profile along the proton track shown in figure Conclusion The development and application of an imaging neutron sensor, based on a CCD, has been described. The sensor can be used to measure SEE-induced spurious charge profiles in two dimensions at 9 µm resolution. This is of importance in the study of neutron-induced single-event effects in microelectronic devices. Example results have been given; a large data set is being analysed in order to characterise the mechanisms and statistics of SEE phenomena including multiple-bit upsets.
5 176 Acknowledgements This work was funded by BAE SYSTEMS Air Systems Warton and the UK Department of Trade and Industry as part of the SPAESRANE (Solutions for the Preservation of Aerospace Electronics Systems Reliability in the Atmospheric Neutron Environment) project. References [1] Messenger G C and Ash M S 1997 Single-Event Phenomena (New York: Chapman & Hall) [2] International Electrotechnical Commission 2004 Process Management for Avionics Industry Standard for the accommodation of Atmospheric Radiation Effects via Single Event Effects within Avionics Electronic Equipment IEC TC107/29/CD (draft) [3] Zeigler J F 1996 Terrestrial Cosmic Rays IBM J. Res. Dev. 40 pp19 39 [4] Dyer C, Truscott P, Sanderson C, Colwell B, Chugg A, Jones R, MacDiarmid I and Johansson K 2000 Cosmic radiation effects on avionics, an increasing hazard in the new millennium? Proc. ICAS 2000 Congress (Harrogate) [5] Blackmore E W, Dodd P E and Shaneyfelt M R 2003 Improved capabilities for proton and neutron irradiations at TRIUMF, IEEE NSREC 2003 Radiation Effects Data Workshop. Available online at [accessed 14 March 2005] [6] Kodak Image Sensor Solutions 2003 Kodak KAF0402E/ME Device Performance Specification. Available online at fullframe/kaf-0402elongspec.pdf [accessed 14 March 2005] [7] Chugg A M, Jones R, Moutrie M J and Truscott P R 2004 Analyses of images of neutron interactions and single particle displacement damage in CCD arrays IEEE Trans. Nuc. Sci. NS-51 II [8] Chugg A M, Moutrie M J and Jones R 2004 Broadening of the variance of the number of upsets in a read-cycle by MBUs NSREC 2004 IEEE Trans. Nuc. Sci. NS-51 II
Failures of MOSFETs in Terrestrial Power Electronics Due to Single Event Burnout
Failures of MOSFETs in Terrestrial Power Electronics Due to Single Event Burnout C. Donovan Davidson P.Eng. V.P. of Research and Development Argus Technologies Ltd. 5700 Sidley St., Burnaby, B.C. V5J5E5
More informationSEU effects in registers and in a Dual-Ported Static RAM designed in a 0.25 µm CMOS technology for applications in the LHC
SEU effects in registers and in a Dual-Ported Static RAM designed in a 0.25 µm CMOS technology for applications in the LHC F.Faccio 1, K.Kloukinas 1, G.Magazzù 2, A.Marchioro 1 1 CERN, 1211 Geneva 23,
More informationCosmic Rays induced Single Event Effects in Power Semiconductor Devices
Cosmic Rays induced Single Event Effects in Power Semiconductor Devices Giovanni Busatto University of Cassino ITALY Outline Introduction Cosmic rays in Space Cosmic rays at Sea Level Radiation Effects
More informationProton induced leakage current in CCDs
Proton induced leakage current in CCDs David R. Smith* a, Andrew D. Holland a, Mark S. Robbins b, Richard M. Ambrosi a, Ian B. Hutchinson a a University of Leicester, Space Research Centre, University
More informationHighly Miniaturised Radiation Monitor (HMRM) Status Report. Yulia Bogdanova, Nicola Guerrini, Ben Marsh, Simon Woodward, Rain Irshad
Highly Miniaturised Radiation Monitor (HMRM) Status Report Yulia Bogdanova, Nicola Guerrini, Ben Marsh, Simon Woodward, Rain Irshad HMRM programme aim Aim of phase A/B: Develop a chip sized prototype radiation
More informationthe need for an intensifier
* The LLLCCD : Low Light Imaging without the need for an intensifier Paul Jerram, Peter Pool, Ray Bell, David Burt, Steve Bowring, Simon Spencer, Mike Hazelwood, Ian Moody, Neil Catlett, Philip Heyes Marconi
More information31th March 2017, Annual ILC detector meeting Tohoku University Shunsuke Murai on behalf of FPCCD group
31th March 2017, Annual ILC detector meeting Tohoku University Shunsuke Murai on behalf of FPCCD group 1 Introduction Vertex detector FPCCD Radiation damage Neutron irradiation test Measurement of performance
More informationThe Architecture of the BTeV Pixel Readout Chip
The Architecture of the BTeV Pixel Readout Chip D.C. Christian, dcc@fnal.gov Fermilab, POBox 500 Batavia, IL 60510, USA 1 Introduction The most striking feature of BTeV, a dedicated b physics experiment
More informationDevelopment of a 256-channel Time-of-flight Electronics System For Neutron Beam Profiling
JOURNAL OF L A TEX CLASS FILES, VOL. 14, NO. 8, AUGUST 2015 1 Development of a 256-channel Time-of-flight Electronics System For Neutron Beam Profiling Haolei Chen, Changqing Feng, Jiadong Hu, Laifu Luo,
More informationInitial Results from a Cryogenic Proton Irradiation of a p-channel CCD
Centre for Electronic Imaging Initial Results from a Cryogenic Proton Irradiation of a p-channel CCD Jason Gow Daniel Wood, David Hall, Ben Dryer, Simeon Barber, Andrew Holland and Neil Murray Jason P.
More informationJOSEPH M. BENEDETTO UTMC Microelectronic Systems now Aeroflex Microelectronic Solutions
JOSEPH M. BENEDETTO UTMC Microelectronic Systems now Aeroflex Microelectronic Solutions @IEEE, reprinted from IEEE Spectrum, Volume 35. Number 3, March 1998) What would happen to standard electronics if
More informationThe CMS Silicon Strip Tracker and its Electronic Readout
The CMS Silicon Strip Tracker and its Electronic Readout Markus Friedl Dissertation May 2001 M. Friedl The CMS Silicon Strip Tracker and its Electronic Readout 2 Introduction LHC Large Hadron Collider:
More informationThe SIRAD irradiation facility at the INFN - Legnaro National Laboratory
The SIRAD irradiation facility at the INFN - Legnaro National Laboratory I. Introduction 2 The INFN - Legnaro National Laboratory (LNL) SIRAD beamline http://www.lnl.infn.it 3 What is SIRAD? SIRAD is the
More informationThreshold Voltage and Drain Current Investigation of Power MOSFET ZVN3320FTA by 2D Simulations
Threshold Voltage and Drain Current Investigation of Power MOSFET ZVN3320FTA by 2D Simulations Ramani Kannan, Hesham Khalid Department of Electrical and Electronic Engineering Universiti Teknologi PETRONAS,
More informationMonolithic Pixel Sensors in SOI technology R&D activities at LBNL
Monolithic Pixel Sensors in SOI technology R&D activities at LBNL Lawrence Berkeley National Laboratory M. Battaglia, L. Glesener (UC Berkeley & LBNL), D. Bisello, P. Giubilato (LBNL & INFN Padova), P.
More informationOPTICAL LINK OF THE ATLAS PIXEL DETECTOR
OPTICAL LINK OF THE ATLAS PIXEL DETECTOR K.K. Gan, W. Fernando, P.D. Jackson, M. Johnson, H. Kagan, A. Rahimi, R. Kass, S. Smith Department of Physics, The Ohio State University, Columbus, OH 43210, USA
More informationSINGLE EVENT LATCH-UP TEST REPORT ADCLK925S
SINGLE EVENT LATCH-UP TEST REPORT ADCLK925S April 2016 Generic Radiation Test Report Product: ADCLK925S Effective LET: 85 MeV-cm 2 /mg Fluence: 1E7 Ions/cm 2 Die Type: AD8210 Facilities: TAMU Tested: June
More informationIrradiation Measurements of the Hitachi H8S/2357 MCU.
Irradiation Measurements of the Hitachi H8S/2357 MCU. A. Ferrando 1, C.F. Figueroa 2, J.M. Luque 1, A. Molinero 1, J.J. Navarrete 1, J.C. Oller 1 1 CIEMAT, Avda Complutense 22, 28040 Madrid, Spain 2 IFCA,
More informationInvestigating the Causes of and Possible Remedies for Sensor Damage in Digital Cameras Used on the OMEGA Laser Systems.
Investigating the Causes of and Possible Remedies for Sensor Damage in Digital Cameras Used on the OMEGA Laser Systems Krysta Boccuzzi Our Lady of Mercy High School Rochester, NY Advisor: Eugene Kowaluk
More informationLow Power Dissipation SEU-hardened CMOS Latch
PIERS ONLINE, VOL. 3, NO. 7, 2007 1080 Low Power Dissipation SEU-hardened CMOS Latch Yuhong Li, Suge Yue, Yuanfu Zhao, and Guozhen Liang Beijing Microelectronics Technology Institute, 100076, China Abstract
More informationReal Time Pulse Pile-up Recovery in a High Throughput Digital Pulse Processor
Real Time Pulse Pile-up Recovery in a High Throughput Digital Pulse Processor Paul A. B. Scoullar a, Chris C. McLean a and Rob J. Evans b a Southern Innovation, Melbourne, Australia b Department of Electrical
More informationRadiation Testing Campaign for a New Miniaturised Space GPS Receiver
Radiation Testing Campaign for a New Miniaturised Space GPS Receiver Craig Underwood Surrey Space Centre University of Surrey, Guildford, Surrey, UK c.underwood@surrey.ac.uk Martin Unwin Surrey Satellite
More informationSouthern Methodist University Dallas, TX, Southern Methodist University Dallas, TX, 75275
Single Event Effects in a 0.25 µm Silicon-On-Sapphire CMOS Technology Wickham Chen 1, Tiankuan Liu 2, Ping Gui 1, Annie C. Xiang 2, Cheng-AnYang 2, Junheng Zhang 1, Peiqing Zhu 1, Jingbo Ye 2, and Ryszard
More informationPoS(VERTEX2015)008. The LHCb VELO upgrade. Sophie Elizabeth Richards. University of Bristol
University of Bristol E-mail: sophie.richards@bristol.ac.uk The upgrade of the LHCb experiment is planned for beginning of 2019 unitl the end of 2020. It will transform the experiment to a trigger-less
More informationDesign of Soft Error Tolerant Memory and Logic Circuits
Design of Soft Error Tolerant Memory and Logic Circuits Shah M. Jahinuzzaman PhD Student http://vlsi.uwaterloo.ca/~smjahinu Graduate Student Research Talks, E&CE January 16, 2006 CMOS Design and Reliability
More informationSimulation of High Resistivity (CMOS) Pixels
Simulation of High Resistivity (CMOS) Pixels Stefan Lauxtermann, Kadri Vural Sensor Creations Inc. AIDA-2020 CMOS Simulation Workshop May 13 th 2016 OUTLINE 1. Definition of High Resistivity Pixel Also
More informationApplication of CMOS sensors in radiation detection
Application of CMOS sensors in radiation detection S. Ashrafi Physics Faculty University of Tabriz 1 CMOS is a technology for making low power integrated circuits. CMOS Complementary Metal Oxide Semiconductor
More information30 th April 2008 Glasgow DSpace Service
Triger, S. and Wallace, J. and Saillant, J-F. and Cochran, S. and Cumming, D.R.S. (2007) MOSAIC: An integrated ultrasonic 2-D array system. In, IEEE International Ultrasonics Symposium, 28-31 October 2007,
More informationEvaluation of the Radiation Tolerance of Several Generations of SiGe Heterojunction Bipolar Transistors Under Radiation Exposure
1 Evaluation of the Radiation Tolerance of Several Generations of SiGe Heterojunction Bipolar Transistors Under Radiation Exposure J. Metcalfe, D. E. Dorfan, A. A. Grillo, A. Jones, F. Martinez-McKinney,
More informationX-ray Radiation Hardness of Fully-Depleted SOI MOSFETs and Its Improvement
June 4, 2015 X-ray Radiation Hardness of Fully-Depleted SOI MOSFETs and Its Improvement Ikuo Kurachi 1, Kazuo Kobayashi 2, Hiroki Kasai 3, Marie Mochizuki 4, Masao Okihara 4, Takaki Hatsui 2, Kazuhiko
More informationHigh-Efficiency L-Band 200-W GaN HEMT for Space Applications
INFOCOMMUNICATIONS High-Efficiency L-Band 200-W GaN HEMT for Space Applications Ken OSAWA*, Hiroyuki YOSHIKOSHI, Atsushi NITTA, Tsuneyuki TANAKA, Eizo MITANI, and Tomio SATOH ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
More informationTID Influence on the SEE sensitivity of Active EEE components. Lionel Salvy
TID Influence on the SEE sensitivity of Active EEE components Lionel Salvy Purpose of the study During space application, devices are subject to TID and SEE at the same time But part radiation qualification
More informationSilicon Sensor Developments for the CMS Tracker Upgrade
Silicon Sensor Developments for the CMS Tracker Upgrade on behalf of the CMS tracker collaboration University of Hamburg, Germany E-mail: Joachim.Erfle@desy.de CMS started a campaign to identify the future
More informationImaging Photometer and Colorimeter
W E B R I N G Q U A L I T Y T O L I G H T. /XPL&DP Imaging Photometer and Colorimeter Two models available (photometer and colorimetry camera) 1280 x 1000 pixels resolution Measuring range 0.02 to 200,000
More informationProduction of HPDs for the LHCb RICH Detectors
Production of HPDs for the LHCb RICH Detectors LHCb RICH Detectors Hybrid Photon Detector Production Photo Detector Test Facilities Test Results Conclusions IEEE Nuclear Science Symposium Wyndham, 24 th
More informationRadiation-hard ASICs for Optical Data Transmission in the ATLAS Pixel Detector
Radiation-hard ASICs for Optical Data Transmission in the ATLAS Pixel Detector P. D. Jackson 1, K.E. Arms, K.K. Gan, M. Johnson, H. Kagan, A. Rahimi, C. Rush, S. Smith, R. Ter-Antonian, M.M. Zoeller Department
More informationSCINTILLATING FIBER DOSIMETER ARRAY
SCINTILLATING FIBER DOSIMETER ARRAY FIELD OF THE INVENTION [0001] This invention relates generally to the field of dosimetry and, more particularly, to rapid, high-resolution dosimeters for advanced treatment
More informationMinnesota Rules, Chapter 4732 X-ray Revision
Minnesota Rules, Chapter 4732 X-ray Revision DRAFT INDUSTRIAL X-RAY SYSTEMS DEFINTIONS, 1.0 4732.####. INDUSTRIAL X-RAY SYSTEMS DEFINITIONS. Subpart 1. Scope. For purposes of industrial x-ray systems under
More informationMilitary Performance Specifications
RADIATION OWNER S MANUAL RHA-Related Documents Military Performance Specifications 19500 General Specification for Semiconductor Devices 38534 Performance Specifications for Hybrid Microcircuits 38535
More informationTID Influence on the SEE sensitivity of Active EEE components
TID Influence on the SEE sensitivity of Active EEE components ESA Contract No. 4000111336 Lionel Salvy, Benjamin Vandevelde, Lionel Gouyet Anne Samaras, Athina Varotsou, Nathalie Chatry Alexandre Rousset,
More informationElectrical Characterization of Commercial Power MOSFET under Electron Radiation
Indonesian Journal of Electrical Engineering and Computer Science Vol. 8, No. 2, November 2017, pp. 462 ~ 466 DOI: 10.11591/ijeecs.v8.i2.pp462-466 462 Electrical Characterization of Commercial Power MOSFET
More informationPoS(TIPP2014)382. Test for the mitigation of the Single Event Upset for ASIC in 130 nm technology
Test for the mitigation of the Single Event Upset for ASIC in 130 nm technology Ilaria BALOSSINO E-mail: balossin@to.infn.it Daniela CALVO E-mail: calvo@to.infn.it E-mail: deremigi@to.infn.it Serena MATTIAZZO
More informationAN INITIAL investigation into the effects of proton irradiation
IEEE TRANSACTIONS ON ELECTRON DEVICES, VOL. 53, NO. 2, FEBRUARY 2006 205 Proton Irradiation of EMCCDs David R. Smith, Richard Ingley, and Andrew D. Holland Abstract This paper describes the irradiation
More informationFully depleted, thick, monolithic CMOS pixels with high quantum efficiency
Fully depleted, thick, monolithic CMOS pixels with high quantum efficiency Andrew Clarke a*, Konstantin Stefanov a, Nicholas Johnston a and Andrew Holland a a Centre for Electronic Imaging, The Open University,
More informationCMS Beam Condition Monitoring Wim de Boer, Hannes Bol, Alexander Furgeri, Steffen Muller
CMS Beam Condition Monitoring Wim de Boer, Hannes Bol, Alexander Furgeri, Steffen Muller BCM2 8diamonds BCM1 8diamonds each BCM2 8diamonds Beam Condition Monitoring at LHC BCM at LHC is done by about 3700
More informationAIDA-2020 Advanced European Infrastructures for Detectors at Accelerators. Deliverable Report. CERN pixel beam telescope for the PS
AIDA-2020-D15.1 AIDA-2020 Advanced European Infrastructures for Detectors at Accelerators Deliverable Report CERN pixel beam telescope for the PS Dreyling-Eschweiler, J (DESY) et al 25 March 2017 The AIDA-2020
More informationSINGLE EVENT EFFECTS TEST REPORT SEL: 125⁰C SET: 25⁰C. SEL: MeV cm 2 /mg SET: ( ) MeV cm 2 /mg. RADEF, University of Jyväskylä
SINGLE EVENT EFFECTS TEST REPORT PRODUCT: ADL5501 DIE TYPE: ADL5501 Rev A DATE CODE: 1138 CASE TEMPERATURE: EFFECTIVE LET: SEL: 125⁰C SET: 25⁰C SEL: 84.85 MeV cm 2 /mg SET: (3.63 60) MeV cm 2 /mg TOTAL
More informationChromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC
Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC R. Bellazzini a,b, G. Spandre a*, A. Brez a, M. Minuti a, M. Pinchera a and P. Mozzo b a INFN Pisa
More informationWhy p-type is better than n-type? or Electric field in heavily irradiated silicon detectors
Why p-type is better than n-type? or Electric field in heavily irradiated silicon detectors G.Kramberger, V. Cindro, I. Mandić, M. Mikuž, M. Milovanović, M. Zavrtanik Jožef Stefan Institute Ljubljana,
More informationSouthern Methodist University Dallas, TX, Department of Physics. Southern Methodist University Dallas, TX, 75275
Total Ionization Dose Effect Studies of a 0.25 µm Silicon-On-Sapphire CMOS Technology Tiankuan Liu 2, Ping Gui 1, Wickham Chen 1, Jingbo Ye 2, Cheng-AnYang 2, Junheng Zhang 1, Peiqing Zhu 1, Annie C. Xiang
More informationAVALANCHE PHOTODIODES FOR THE CMS ELECTROMAGNETIC CALORIMETER
AVALANCHE PHOTODIODES FOR THE CMS ELECTROMAGNETIC CALORIMETER B. Patel, R. Rusack, P. Vikas(email:Pratibha.Vikas@cern.ch) University of Minnesota, Minneapolis, U.S.A. Y. Musienko, S. Nicol, S.Reucroft,
More informationFAST NEUTRON AND GAMMA-RAY INTERROGATION OF AIR CARGO CONTAINERS
Third Research Coordination Meeting: IAEA CRP on Neutron Based Techniques for the Detection of Illicit Materials and Explosives, Johannesburg, 16-20 November 2009 FAST NEUTRON AND GAMMA-RAY INTERROGATION
More informationA monolithic pixel sensor with fine space-time resolution based on silicon-on-insulator technology for the ILC vertex detector
A monolithic pixel sensor with fine space-time resolution based on silicon-on-insulator technology for the ILC vertex detector, Miho Yamada, Toru Tsuboyama, Yasuo Arai, Ikuo Kurachi High Energy Accelerator
More informationMy projects at a glance
My projects at a glance Michał Gumiela Student at The Faculty of Computer Science, Electronics and Telecommunications AGH University of Science and Technology in Cracow October 31, 2013 Abstract The article
More informationRadiation Effects on DC-DC Converters
Radiation Effects on DC-DC Converters DC-DC Converters frequently must operate in the presence of various forms of radiation. The environment that the converter is exposed to may determine the design and
More informationACT 5028 Resolver-To-Digital Converter. Heavy-Ion Irradiation Test Results for the ACT5028 Resolver-to-Digital Converter
Application Note ACT 5028 Resolver-To-Digital Converter Heavy-Ion Irradiation Test Results for the ACT5028 Resolver-to-Digital Converter by Nathan Nowlin, Steve McEndree, Joseph Benedetto Mission Research
More informationABSTRACT. Keywords: 0,18 micron, CMOS, APS, Sunsensor, Microned, TNO, TU-Delft, Radiation tolerant, Low noise. 1. IMAGERS FOR SPACE APPLICATIONS.
Active pixel sensors: the sensor of choice for future space applications Johan Leijtens(), Albert Theuwissen(), Padmakumar R. Rao(), Xinyang Wang(), Ning Xie() () TNO Science and Industry, Postbus, AD
More informationPixel CCD RASNIK. Kevan S Hashemi and James R Bensinger Brandeis University May 1997
ATLAS Internal Note MUON-No-180 Pixel CCD RASNIK Kevan S Hashemi and James R Bensinger Brandeis University May 1997 Introduction This note compares the performance of the established Video CCD version
More informationThis is a preview - click here to buy the full publication
TECHNICAL REPORT IEC TR 63170 Edition 1.0 2018-08 colour inside Measurement procedure for the evaluation of power density related to human exposure to radio frequency fields from wireless communication
More informationSingle Event Effects Testing of the ISL7124SRH Quad Operational Amplifier June 2002
Single Event Effects Testing of the ISL7124SRH Quad Operational Amplifier June 2002 Purpose - This report describes the results of single event effects testing of the ISL7124SRH quad operational amplifier
More informationHigh SEE Tolerance in a Radiation Hardened CMOS Image Sensor Designed for the Meteosat Third Generation FCI-VisDA Instrument
CMOS Image Sensors for High Performance Applications 18 th and 19 th Nov 2015 High SEE Tolerance in a Radiation Hardened CMOS Image Sensor Designed for the Meteosat Third Generation FCI-VisDA Instrument
More informationQualification Tests of Micro-camera Modules for Space Applications
Trans. JSASS Aerospace Tech. Japan Vol. 9, pp. 15-20, 2011 Qualification Tests of Micro-camera Modules for Space Applications By Shinichi KIMURA and Akira MIYASAKA Department of Electrical Engineering,
More informationTest bench for evaluation of radiation hardness in Application Specific Integrated Circuits
SHEP 2016 Workshop on Sensors and High Energy Physics Test bench for evaluation of radiation hardness in Application Specific Integrated Circuits Vlad Mihai PLĂCINTĂ 1,3 Lucian Nicolae COJOCARIU 1,2 1.
More informationPulse Shape Analysis for a New Pixel Readout Chip
Abstract Pulse Shape Analysis for a New Pixel Readout Chip James Kingston University of California, Berkeley Supervisors: Daniel Pitzl and Paul Schuetze September 7, 2017 1 Table of Contents 1 Introduction...
More informationLayout and prototyping of the new ATLAS Inner Tracker for the High Luminosity LHC
Layout and prototyping of the new ATLAS Inner Tracker for the High Luminosity LHC Ankush Mitra, University of Warwick, UK on behalf of the ATLAS ITk Collaboration PSD11 : The 11th International Conference
More informationA new strips tracker for the upgraded ATLAS ITk detector
A new strips tracker for the upgraded ATLAS ITk detector, on behalf of the ATLAS Collaboration : 11th International Conference on Position Sensitive Detectors 3-7 The Open University, Milton Keynes, UK.
More informationPERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY
12 th A-PCNDT 2006 Asia-Pacific Conference on NDT, 5 th 10 th Nov 2006, Auckland, New Zealand PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY Rajashekar
More informationA CMOS Image Sensor with Ultra Wide Dynamic Range Floating-Point Pixel-Level ADC
A 640 512 CMOS Image Sensor with Ultra Wide Dynamic Range Floating-Point Pixel-Level ADC David X.D. Yang, Abbas El Gamal, Boyd Fowler, and Hui Tian Information Systems Laboratory Electrical Engineering
More informationIn the name of God, the most merciful Electromagnetic Radiation Measurement
In the name of God, the most merciful Electromagnetic Radiation Measurement In these slides, many figures have been taken from the Internet during my search in Google. Due to the lack of space and diversity
More informationShort Course Program
Short Course Program TECHNIQUES FOR SEE MODELING AND MITIGATION OREGON CONVENTION CENTER OREGON BALLROOM 201-202 MONDAY, JULY 11 8:00 AM 8:10 AM 9:40 AM 10:10 AM 11:40 AM 1:20 PM 2:50 PM 3:20 PM 4:50 PM
More informationElectronic Radiation Hardening - Technology Demonstration Activities (TDAs)
Electronic Radiation Hardening - Technology Demonstration Activities (TDAs) Véronique Ferlet-Cavrois ESA/ESTEC Acknowledgements to Ali Mohammadzadeh, Christian Poivey, Marc Poizat, Fredrick Sturesson ESA/ESTEC,
More informationMTF and PSF measurements of the CCD detector for the Euclid visible channel
MTF and PSF measurements of the CCD273-84 detector for the Euclid visible channel I. Swindells* a, R. Wheeler a, S. Darby a, S. Bowring a, D. Burt a, R. Bell a, L. Duvet b, D. Walton c, R. Cole c a e2v
More informationX-RAY COMPUTED TOMOGRAPHY
X-RAY COMPUTED TOMOGRAPHY Bc. Jan Kratochvíla Czech Technical University in Prague Faculty of Nuclear Sciences and Physical Engineering Abstract Computed tomography is a powerful tool for imaging the inner
More informationThe software and hardware for the ground testing of ALFA- ELECTRON space spectrometer
Journal of Physics: Conference Series PAPER OPEN ACCESS The software and hardware for the ground testing of ALFA- ELECTRON space spectrometer To cite this article: A G Batischev et al 2016 J. Phys.: Conf.
More informationSTUDIES OF INTERACTION OF PARTIALLY COHERENT LASER RADIATION WITH PLASMA
STUDIES OF INTERACTION OF PARTIALLY COHERENT LASER RADIATION WITH PLASMA Alexander N. Starodub Deputy Director N.G.Basov Institute of Quantum Radiophysics of P.N.Lebedev Physical Institute of the RAS Leninsky
More informationDetailed Characterisation of a New Large Area CCD Manufactured on High Resistivity Silicon
Detailed Characterisation of a New Large Area CCD Manufactured on High Resistivity Silicon Mark S. Robbins *, Pritesh Mistry, Paul R. Jorden e2v technologies Ltd, 106 Waterhouse Lane, Chelmsford, Essex
More informationSTM RH-ASIC capability
STM RH-ASIC capability JAXA 24 th MicroElectronic Workshop 13 th 14 th October 2011 Prepared by STM Crolles and AeroSpace Unit Deep Sub Micron (DSM) is strategic for Europe Strategic importance of European
More informationThe Effect of Quantization Upon Modulation Transfer Function Determination
The Effect of Quantization Upon Modulation Transfer Function Determination R. B. Fagard-Jenkin, R. E. Jacobson and J. R. Jarvis Imaging Technology Research Group, University of Westminster, Watford Road,
More informationStudy of irradiated 3D detectors. University of Glasgow, Scotland. University of Glasgow, Scotland
Department of Physics & Astronomy Experimental Particle Physics Group Kelvin Building, University of Glasgow Glasgow, G12 8QQ, Scotland Telephone: ++44 (0)141 339 8855 Fax: +44 (0)141 330 5881 GLAS-PPE/2002-20
More information2 nd Generation CMOS Charge Transfer TDI: Results on Proton Irradiation
2 nd Generation CMOS Charge Transfer TDI: Results on Proton Irradiation F. Mayer, J. Endicott, F. Devriere e2v, Avenue de Rochepleine, BP123, 38521 Saint Egrève Cedex, France J. Rushton, K. Stefanov, A.
More informationTHE CCD RIDDLE REVISTED: SIGNAL VERSUS TIME LINEAR SIGNAL VERSUS VARIANCE NON-LINEAR
THE CCD RIDDLE REVISTED: SIGNAL VERSUS TIME LINEAR SIGNAL VERSUS VARIANCE NON-LINEAR Mark Downing 1, Peter Sinclaire 1. 1 ESO, Karl Schwartzschild Strasse-2, 85748 Munich, Germany. ABSTRACT The photon
More informationModule 1: Introduction to Experimental Techniques Lecture 2: Sources of error. The Lecture Contains: Sources of Error in Measurement
The Lecture Contains: Sources of Error in Measurement Signal-To-Noise Ratio Analog-to-Digital Conversion of Measurement Data A/D Conversion Digitalization Errors due to A/D Conversion file:///g /optical_measurement/lecture2/2_1.htm[5/7/2012
More informationBackgrounds in DMTPC. Thomas Caldwell. Massachusetts Institute of Technology DMTPC Collaboration
Backgrounds in DMTPC Thomas Caldwell Massachusetts Institute of Technology DMTPC Collaboration Cygnus 2009 June 12, 2009 Outline Expected backgrounds for surface run Detector operation Characteristics
More informationPersistence Characterisation of Teledyne H2RG detectors
Persistence Characterisation of Teledyne H2RG detectors Simon Tulloch European Southern Observatory, Karl Schwarzschild Strasse 2, Garching, 85748, Germany. Abstract. Image persistence is a major problem
More informationUltra-high resolution 14,400 pixel trilinear color image sensor
Ultra-high resolution 14,400 pixel trilinear color image sensor Thomas Carducci, Antonio Ciccarelli, Brent Kecskemety Microelectronics Technology Division Eastman Kodak Company, Rochester, New York 14650-2008
More information10/3/2012. Study Harder
This presentation is a professional collaboration of development time prepared by: Rex Christensen Terri Jurkiewicz and Diane Kawamura Study Harder CR detection is inefficient, inferior to film screen
More informationA Real Time Digital Signal Processing Readout System for the PANDA Straw Tube Tracker
A Real Time Digital Signal Processing Readout System for the PANDA Straw Tube Tracker a, M. Drochner b, A. Erven b, W. Erven b, L. Jokhovets b, G. Kemmerling b, H. Kleines b, H. Ohm b, K. Pysz a, J. Ritman
More informationA Readout ASIC for CZT Detectors
A Readout ASIC for CZT Detectors L.L.Jones a, P.Seller a, I.Lazarus b, P.Coleman-Smith b a STFC Rutherford Appleton Laboratory, Didcot, OX11 0QX, UK b STFC Daresbury Laboratory, Warrington WA4 4AD, UK
More informationmetro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD.
metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD. Product brocure 1 is reliable, fast and easiest to use tool designed for routine
More informationThe Metrication Waveforms
The Metrication of Low Probability of Intercept Waveforms C. Fancey Canadian Navy CFB Esquimalt Esquimalt, British Columbia, Canada cam_fancey@hotmail.com C.M. Alabaster Dept. Informatics & Sensor, Cranfield
More informationA 3 Mpixel ROIC with 10 m Pixel Pitch and 120 Hz Frame Rate Digital Output
A 3 Mpixel ROIC with 10 m Pixel Pitch and 120 Hz Frame Rate Digital Output Elad Ilan, Niv Shiloah, Shimon Elkind, Roman Dobromislin, Willie Freiman, Alex Zviagintsev, Itzik Nevo, Oren Cohen, Fanny Khinich,
More informationEffects of Ionizing Radiation on Digital Single Event Transients in a 180-nm Fully Depleted SOI Process
Effects of Ionizing Radiation on Digital Single Event Transients in a 180-nm Fully Depleted SOI Process The MIT Faculty has made this article openly available. Please share how this access benefits you.
More information3084 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 60, NO. 4, AUGUST 2013
3084 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 60, NO. 4, AUGUST 2013 Dummy Gate-Assisted n-mosfet Layout for a Radiation-Tolerant Integrated Circuit Min Su Lee and Hee Chul Lee Abstract A dummy gate-assisted
More informationIntroduction. Lighting
&855(17 )8785(75(1'6,10$&+,1(9,6,21 5HVHDUFK6FLHQWLVW0DWV&DUOLQ 2SWLFDO0HDVXUHPHQW6\VWHPVDQG'DWD$QDO\VLV 6,17()(OHFWURQLFV &\EHUQHWLFV %R[%OLQGHUQ2VOR125:$< (PDLO0DWV&DUOLQ#HF\VLQWHIQR http://www.sintef.no/ecy/7210/
More informationCCD47-10 NIMO Back Illuminated Compact Pack High Performance CCD Sensor
CCD47-10 NIMO Back Illuminated Compact Pack High Performance CCD Sensor FEATURES 1024 by 1024 Nominal (1056 by 1027 Usable Pixels) Image area 13.3 x 13.3mm Back Illuminated format for high quantum efficiency
More informationSINGLE EVENT UPSET (SEU): DIAGNOSTIC AND ERROR CORRECTION SYSTEM FOR AVIONCS DEVICE
XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 2009, Lisbon, Portugal SINGLE EVENT UPSET (SEU): DIAGNOSTIC AND ERROR CORRECTION SYSTEM FOR AVIONCS DEVICE Lorenzo Ciani 1, Marcantonio
More informationQuality Assurance for the ATLAS Pixel Sensor
Quality Assurance for the ATLAS Pixel Sensor 1st Workshop on Quality Assurance Issues in Silicon Detectors J. M. Klaiber-Lodewigs (Univ. Dortmund) for the ATLAS pixel collaboration Contents: - role of
More information10/26/2015. Study Harder
This presentation is a professional collaboration of development time prepared by: Rex Christensen Terri Jurkiewicz and Diane Kawamura Study Harder CR detection is inefficient, inferior to film screen
More informationFEATURES GENERAL DESCRIPTION. CCD Element Linear Image Sensor CCD Element Linear Image Sensor
CCD 191 6000 Element Linear Image Sensor FEATURES 6000 x 1 photosite array 10µm x 10µm photosites on 10µm pitch Anti-blooming and integration control Enhanced spectral response (particularly in the blue
More informationCOTS FPGA/SRAM Irradiations Using a Dedicated Testing Infrastructure for Characterization of Large Component Batches
CERN-ACC-2015-0001 Slawosz.Uznanski@cern.ch COTS /SRAM Irradiations Using a Dedicated Testing Infrastructure for Characterization of Large Component Batches Slawosz Uznanski, Benjamin Todd, Johannes Walter,
More information