F4 PLUS F4 PLUS (AS05850) Apparecchiatura elettronica SCHEMA ELETTRICO E COLLEGAMENTI. Electronic control unit ELECTRICAL CONNECTIONS
|
|
- Prosper Bryant
- 6 years ago
- Views:
Transcription
1 F4 PLUS F4 PLUS (AS05850) Apparecchiatura elettrica SCHEMA ELETTRICO E COLLEGAMENTI Electric ctrol unit ELECTRICAL CNECTIS I UK
2 2 F4 PLUS SCHEMA ELETTRICO / ELECTRICAL CNECTIS 91 POWER L11 DIP2 F1-5A F2T-160mA L9 L10 M4 FORCE - RUN TIME P.S. TIME PAUSE DIP1 OPEN CLOSE OPEN CLOSE 230 Vac ~ NEUTRAL 230 Vac ~ PHASE EARTH EARTH FCC (NC) FCA (NC) FCC (NC) FCA (NC) PHOTO (NC) START (NO) 24Vac EL 12Vac STOP (NC)/SAF.(8K2) PED (NO) ANT L1 L2 L3 L4 L5 L6 L7 L W MAX L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 LED FCC FCA FCC FCA PHOTO START STOP PED - SAFETY (8K2) POWER
3 F4 PLUS 3 COLLEGAMENTO ALIMENTAZIE / POWER SUPPLY CNECTI PHASE 2 NEUTRAL 23 INTERRUTTORE MAGNETOTERMICO OVERCURRENT CIRCUIT BREAKER INTERRUTTORE DIFFERENZIALE RESIDUAL-CURRENT DEVICE PHASE NEUTRAL COLLEGAMENTO DI TERRA / EARTH CNECTI 3 COLLEGAMENTO EGGIANTE / FLASHING LIGHT CNECTI 4 9 DIP1_9 = Vac 40W max M4 DIP2_2 = DIP1_9 = 230 Vac 40W max
4 4 F4 PLUS COLLEGAMENTO SPIA DI SEGNALAZIE / WARNING LIGHT CNECTI 4 5 M4 2 DIP2_2 = 24Vac 3W MAX 24Vac COLLEGAMENTO LUCE DI CORTESIA / COURTESY LIGHT CNECTI DIP1_9 = 4 2 Min 2 Min COLLEGAMENTO DISPOSITIVI DI ANDO / CTROL DEVICES CNECTI 4 7 START (NO) PED (NO) COLLEGAMENTO ELETTROSERRATURA / ELECTRICAL LOCK CNECTI 4 8 EL 12Vac
5 F4 PLUS 5 COLLEGAMENTO FOTOCELLULE / PHOTOCELLS CNECTI CSULTARE IL MANUALE DELLE FOTOCELLULE PER MAGGIORI DETTAGLI / REFER TO THE PHOTOCELLS MANUAL FOR DETAILED CNECTI DIAGRAMS 4 ( AU02000 SINCRIZZATE / SYNCHRIZED ) COLLEGAMENTO FOTOCELLULE / PHOTOCELLS CNECTI PHOTO (NC) PHOTO (NC) 24Vac 24Vac TX ( AU AU01910 SINCRIZZATE / SYNCHRIZED ) COLLEGAMENTO DISPOSITIVO DI SICUREZZA 8K2 / 8K2 SAFETY DEVICE CNECTI STOP (NC)/SAF.(8K2) COLLEGAMENTO STOP / STOP CNECTI STOP (NC)/SAF.(8K2) 1 1 TX DIP2_1 = DIP2_1 = 8K TX TX K
6 6 F4 PLUS IMPOSTAZIE DI DEFAULT DIP1 / DIP1 DEFAULT SETTINGS 13 4 MANTENIMENTO BLOCCO OLEODINAMICO ABILITATO HYDRAULIC BLOCK MAINTENANCE ENABLED MORSETTI 7-8 E EGGIANTE A LUCE FISSA TERMINAL INPUTS N 7-8 AS FIXED FLASHING LIGHT INGRESSO PHOTO DISABILITATO / PHOTO INPUT DISABLED FCC DISABILITATO / FCC DISABLED FCA DISABILITATO / FCA DISABLED FCC DISABILITATO / FCC DISABLED FCA DISABILITATO / FCA DISABLED COLPO D ARIETE ABILITATO / HAMMER STROKE ENABLED LOGICA DI FUNZIAMENTO CDOMINIALE / WORKING LOGIC - AUTOMATIC FOTOCELLULA IN APERTURA ABILITATA PHOTOCELL ACTIVE DURING OPENING ENABLED MANTENIMENTO BLOCCO OLEODINAMICO DISABILITATO HYDRAULIC BLOCK MAINTENANCE DISABLED MORSETTI 7-8 E LUCE DI CORTESIA TERMINAL INPUTS N 7-8 AS COURTESY LIGHT INGRESSO PHOTO ABILITATO / PHOTO INPUT ENABLED FCC ABILITATO / FCC ENABLED FCA ABILITATO / FCA ENABLED FCC ABILITATO / FCC ENABLED FCA ABILITATO / FCA ENABLED COLPO D ARIETE DISABILITATO / HAMMER STROKE DISABLED LOGICA DI FUNZIAMENTO PASSO PASSO C STOP WORKING LOGIC - STEP BY STEP WITH STOP FOTOCELLULA IN APERTURA DISABILITATA PHOTOCELL ACTIVE DURING OPENING DISABLED IMPOSTAZIE DI DEFAULT DIP2 / DIP2 DEFAULT SETTINGS 14 MORSETTO M4 E SPIA / TERMINAL BLOCK M4 AS WARNING LIGHT MORSETTI 23 E COSTA 8K2 / TERMINAL INPUT N 23 AS 8K2 SAFETY DEVICE MORSETTO M4 E EGGIANTE / TERMINAL BLOCK M4 AS FLASHING LIGHT MORSETTI 23 E STOP N.C. / TERMINAL INPUT N 23 AS N.C. STOP TRIMMER FORCE MOVEMENT SPEED : 100% - THRUST FORCE: 25% VELOCITA ANTA : 100% - FORZA DI SPINTA : 25% MOVEMENT SPEED : 100% - THRUST FORCE: 100% VELOCITA ANTA : 100% - FORZA DI SPINTA : 100%
7 F4 PLUS 7 TRIMMER RUN TIME TEMPO DI LAVORO 2 SECDI RUN TIME 2 SECDS TEMPO DI LAVORO 103 SECDI RUN TIME 103 SECDS TRIMMER P.S. TIME SFASAMENTO ANTE DISABILITATO LEAVES PHASE SHIFT TIME DISABLED SFASAMENTO ANTA 1 IN CHIUSURA: 20 SECDI LEAF 1 CLOSING PHASE SHIFT TIME: 20 SECDS TEMPO SFASAMENTO ANTA 2 IN APERTURA: FISSO 2 SECDI LEAF 2 CLOSING PHASE SHIFT TIME: 2 SECDS NOT ADJUSTABLE TRIMMER PAUSE CHIUSURA AUTOMATICA DISABILITATA AUTOMATIC CLOSING DISABLED PAUSA 3 SECDI PAUSE 3 SECDS TEMPO PAUSA 103 SECDI PAUSE 103 SECDS
8 Cod. AIC / Rev. 02 GI.BI.DI. S.r.l. Via Abete Brennero, 177/B Poggio Rusco (MN) - ITALY Tel Fax info@gibidi.com Numero Verde: w w w. g i b i d i. c o m
SC230 (AS05710/115V- AS05711/115V) Apparecchiatura elettronica SCHEMA ELETTRICO E COLLEGAMENTI. Electronic control unit ELECTRICAL CONNECTIONS
SC SC230 (AS05710/115V- AS05711/115V) Apparecchiatura elettronica SCHEMA ELETTRICO E COLLEGAMENTI Electronic control unit ELECTRICAL CNECTIS I UK 2 SC230 SCHEMA ELETTRICO / ELECTRICAL CNECTIS 91 G:B:D:055G3
More informationSC24 (AS05690-AS05700) Apparecchiatura elettronica SCHEMA ELETTRICO E COLLEGAMENTI. Electronic control unit ELECTRICAL CONNECTIONS
SC SC24 (AS05690-AS05700) Apparecchiatura elettronica SCHEMA ELETTRICO E COLLEGAMENTI Electronic control unit ELECTRICAL CNECTIS I UK 2 SC24 SCHEMA ELETTRICO / ELECTRICAL CNECTIS 91 G:B:D: SW4 OFF 1 2
More informationBE24 BE24 (AS05870) Apparecchiatura elettronica SCHEMA ELETTRICO E COLLEGAMENTI. Electronic control unit ELECTRICAL CONNECTIONS
BE2 BE2 (AS05870) Apparecchiatura elettronica SCHEMA ELETTRICO E COLLEGAMENTI Electronic control unit ELECTRICAL CNECTIS I UK 2 BE2 SCHEMA ELETTRICO / ELECTRICAL CNECTIS 91 NERO/BLACK NERO/BLACK F PHASE
More informationBE24 BE24 (AS05870) Apparecchiatura elettronica SCHEMA ELETTRICO E COLLEGAMENTI. Electronic control unit ELECTRICAL CONNECTIONS
BE2 BE2 (AS05870) Apparecchiatura elettronica SCHEMA ELETTRICO E COLLEGAMENTI Electronic control unit ELECTRICAL CNECTIS I UK 2 BE2 SCHEMA ELETTRICO / ELECTRICAL CNECTIS 91 NERO/BLACK NERO/BLACK F PHASE
More informationELECTRONIC CONTROL UNITS
94 ELECTRONIC CONTROL UNITS DG DIGITAL BOARDS Centrali Digitali Threephase Control Unit (1 motor) Centrale Trifase (1 motore) Gate 1 DG Threephase 380V threephase sliding gate. CONDOMINIUM USE uso condominiale
More information27 HP V I GB I GB FADINI. Dis. N meccanica
110 V I Programmatore elettronico idoneo per cancelli battenti a una o due ante, con o senza finecorsa e per cancelli scorrevoli a una o due ante (max. 0,5 CV con frizione ). Electronic control box suitable
More informationRIGEL 4. D Vers. 02 CONTROL UNIT
D808 0-09-98 Vers. 0 CONTROL UNIT 0 Thank you for buying this product, our company is sure that you will be more than satisfied with the product s performance. The product is supplied an INSTRUCTION MANUAL
More informationDOMINO C R E AT I V E A U T O M AT I O N S. its ergonomic small (but not too small) buttons. the blister pack. interchangeable covers
ACCESSORIES accessories DOMINO DOMINO Dominates any type of system with the ease of a simple gesture that touches an object of high design. DOMINO is reliable and user-friendly with its ergonomic small
More informationIstructions. Central control board for electromechanical gearmotors HERCULES 24V
Central control board for electromechanical gearmotors HERCULES 24V 1 2 Attention! The present user s manual is designed for personnel skilled in installation, not for the final user; the electrician is
More informationT.CO.O - R.CO.O Double
T.CO.O - R.CO.O Double Transceiver system for mechanical safety and 8,K resistive edges RECEIVER R.CO.O Double in box TRANSMITTER T.CO.O Double Cod. 006767 Bidirectional communication RECEIVER R.CO.O Double
More informationD747M GUIDA ALL INSTALLAZIONE INSTALLATION GUIDE INSTALLATIONSANLEITUNG NOTICE D INSTALLATION GUÍA PARA LA INSTALACIÓN
GUIDA ALL INSTALLAZIONE INSTALLATION GUIDE INSTALLATIONSANLEITUNG NOTICE D INSTALLATION GUÍA PARA LA INSTALACIÓN Quadro di comando per uno/due motori 12V con encoder Control panel for one-two 12V motors
More informationThis document is the property of Teleco Automation Srl who reserves all reproduction and copying rights
1- GENERAL DESCRIPTION Electronic for the remote control of tubular motors for roller blinds, rolling shutters, doors with limit switch inside or outside the motor, radio receiver section with transmitter
More informationD705M GUIDA ALL INSTALLAZIONE INSTALLATION GUIDE INSTALLATIONSANLEITUNG NOTICE D INSTALLATION GUÍA PARA LA INSTALACIÓN
GUIDA ALL INSTALLAZIONE INSTALLATION GUIDE INSTALLATIONSANLEITUNG NOTICE D INSTALLATION GUÍA PARA LA INSTALACIÓN Quadro di comando per motoriuttore MASTER20Q Control panel for MASTER20Q gearmotor Steuerplatine
More informationD vers CENTRALINA DI COMANDO CONTROL UNIT UNITÉ DE COMMANDE CENTRAL DE MANDO RIGEL-4 UL
D8340 vers. 03 03--07 I CENTRALINA DI ANDO GB F CONTROL UNIT UNITÉ DE MANDE 8 07908 9 5 4 8 7 E CENTRAL DE MANDO RIGEL-4 UL ISTRUZIONI D USO E DI INSTALLAZIONE INSTALLATION AND USER S MANUAL INSTRUCTIONS
More informationWIRELESS DIMMER FOR HEATING
TELECO AUTOMATI SRL - Via dell Artigianato, 16-31014 Colle Umberto (TV) ITALY TELEPHE: ++39.0438.388511 FAX: ++39.0438.388536 - www.telecoautomation.com This document is the property of Teleco Automation
More informationK580M GUIDA ALL INSTALLAZIONE INSTALLATION GUIDE INSTALLATIONSANLEITUNG NOTICE D INSTALLATION GUÍA PARA LA INSTALACIÓN
GUIDA ALL INSTALLAZIONE INSTALLATION GUIDE INSTALLATIONSANLEITUNG NOTICE D INSTALLATION GUÍA PARA LA INSTALACIÓN D-MNL0 17-01-2011 - Rev.05 Quadro di comando per motoriuttore T-ONE5 e T-ONE8 Control panel
More informationELECTRONIC PANEL MC15
ELECTRONIC PANEL MC15 GB Single-phase electronic control unit for the automation of sliding gates, doors and barriers with incorporated radio receiver. Possibility of integrating a radio system with the
More informationMotor 1- GENERAL DESCRIPTION
1- GENERAL DESCRIPTI TELECO AUTOMATI SRL - Via dell Artigianato, 16-31014 Colle Umberto (TV) ITALY TELEPHE: ++39.0438.388511 FAX: ++39.0438.388536 This document is the property of Teleco Automation Srl
More informationPILOT Instructions 1. APPLICATIONS 2. OPERATING INDICATIONS 3. TERMINAL CONNECTIONS + - ON 3 OFF 10 OFF OFF 18/07/18
EN Instructions 8/07/8. APPLICATIS Control Unit specially designed for roller shutters whose tubular motors have integrated mechanical limit switches. Both radio receiver for emitter operations and Wirelessband
More informationSWING 2 MG MG ELECTRONIC CONTROL UNIT FOR SWING GATES
English 23021093MG ELECTRIC CTROL UNIT FOR SWING GATES SEA S.p.A. Zona industriale 64020 S.ATTO Teramo - (ITALY) Tel. +39 0861 588341 r.a. Fax +39 0861 588344 www.seateam.com seacom@seateam.com INDEX COMPENTS
More informationSpa Control Troubleshooting Guide
Spa Control Troubleshooting Guide Model: RS, Voltage: 0V Major System Components TOPSIDE PANEL SYSTEM PACK FAULT CIRCUIT INTERRUPTER (GFCI) GFCI models vary in size and style. Your GFCI may look different.
More informationALTAIR-P QUADRO COMANDO CONTROL PANEL CENTRALE DE COMMANDE STEUERPLATINE CUADRO DE MANDOS QUADRO DE COMANDO I GB
D811506 ver.03 13-06-07 I GB F D E P QUADRO COMANDO CTROL PANEL CENTRALE DE COMMANDE STEUERPLATINE CUADRO DE MANDOS QUADRO DE COMANDO 8 027908 2 9 5 4 8 4 ALTAIR-P ISTRUZII D USO E DI INSTALLAZIE INSTALLATI
More informationspido Instructions and warnings for the fitter
control electronics spido Instructions and warnings for the fitter Istruzioni ed avvertenze per l installatore Istructions et recommandations pour l installateur Anweisungen und Hinweisefür den Installateur
More informationINDEX. 5...PROGRAMMING st LEVEL PROGRAMMING Modification of the pre-setting...8
INDEX 1...WARNINGS...3 2...TECHNICAL SPECIFICATIONS...3 3...LAYOUT AND COMPONENTS OF 624BLD...3 3.1 Description of components...3 4...ELECTRICAL CONNECTIONS...4 4.1 J1 Terminal-board - Accessories (Fig.
More informationSF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications
Long Range Wireless Applications 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) The SF900C Series Remote Control/Switch Followers are a twoway system designed to
More informationTCO6RX / TCO6TX. Transceiver system for mechanical safety and 8,2K resistive edges. Bidirectional communication
TCO6RX / TCO6TX Transceiver system for mechanical safety and 8,K resistive edges TRANSMITTER : TCO6TX RECEIVER : TCO6RX Bidirectional communication Notified Body Directive 98/7/EC EC ident. N 8 PRASTEL
More informationELECTRONIC CONTROL PANEL FOR 24VDC MOTORS
ELECTRONIC CONTROL PANEL FOR 24VDC MOTORS TECHNICAL INSTALLATION MANUAL FOR AUTOMATIC GATES WARNING! Before installing, thoroughly read this manual that is an integral part of this Kit. QUIKO declines
More informationK125M GUIDA ALL INSTALLAZIONE INSTALLATION GUIDE INSTALLATIONSANLEITUNG NOTICE D INSTALLATION GUÍA PARA LA INSTALACIÓN
GUIDA ALL INSTALLAZIONE INSTALLATION GUIDE INSTALLATIONSANLEITUNG NOTICE D INSTALLATION GUÍA PARA LA INSTALACIÓN Quadro di comando per motoriuttore TONE5B Control panel for TONE5B gearmotor Steuerplatine
More informationE124 control unit rapid guide
E124 E124 control unit rapid guide WARNINGS - Important! For the safety of people, it is important that all the instructions be carefully observed. - Incorrect installation or incorrect use of the product
More informationEco-$mart, Inc. TOLL FREE:(888) FAX:(941)
Eco-$mart, Inc. TOLL FREE:(888)329-2705 FAX:(941)377-9460 info@eco-smart.com www.eco-smart.com Fluorescent High Bay Occupancy Sensor Module Installation Instructions Hubbell Building Automation 9601 Dessau
More informationtem.com
Operatore elettromeccanico per cancelli ad anta battente Istruzioni d uso ed avvertenze Electro-mechanical operator for swing gates Operating instructions and warnings Opérateur électromécanique pour portails
More informationNNext D D P 612 USER S MANUAL LEGRAND VERSION
NNext GB D D P Digital Dimmer Pack ch - A USER S MANUAL LEGRAND VERSION INDEX We congratulate you on your purchase of DDP. Before you proced using this product it should be necessary to read carefully
More informationEnglish GATE 2-24V PLUS
Automazione English 3001135 ELETRONI ONTROL UNIT FOR SWING OPERATORS 4 V D.. SEA (UK) Limited Unit 6A Olton Wharf, Solihull B9 7RN Tel. 011 706 969 Fax 011 764 56034 London Tel. 008 360 80 www.seaukltd.co.uk
More informationPURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES
PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES Kert is always ready to help you! If you need: Advices for the purchase
More informationSF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications
Long Range Wireless Applications 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) The SF900C Series Remote Control/Switch Followers are a twoway system designed to
More informationSKJ. J1939 CANBus Output Signal. Linear Position to 400 inches (10 m) Compact Design Simple To Install User Adjustable Measuring Cable Orientation
SKJ J939 CANBus Output Signal Linear Positi to 4 inches ( m) Compact Design Simple To Install User Adjustable Measuring Cable Orientati SPECIFICATIONS Stroke Range Optis 25 inches (6.4 m), 4 inches (.2
More informationTT 34 MICROPROCESSOR-BASED DIGITAL ELECTRONIC TIMER. User Manual Cod.: ENG - Vr /05 - ISTR-MTT34E03. Index. 1.1 General description
TT 34 MICROPROCESSOR-BASED DIGITAL ELECTRONIC TIMER User Manual Cod.: ENG - Vr. 3-17/5 - ISTR-MTT34E3 ASCON TECNOLOGIC S.r.l. Viale Indipendenza 56, 2729 - VIGEVANO (PV) ITALY TEL.: +39 381 69871 - FAX:
More informationABB AC Brushless Servodrives Manual of the Safety Relay Board
ABB Servomotors ABB AC Brushless Servodrives DGV 700 Converters for Speed, Torque and Positioning Control of Brushless AC Permanent Magnet Servomotors Manual of the Safety Relay Board ABB AC Brushless
More informationBulletin B1243: RIBTW24B-BCAI RIBMNW24B-BCAI
Bulletin B243: RIBTW24B-BC RIBMNW24B-BC Enclosed BACnet Network Relay Device RIBTW24B-BC RIBMNW24B-BC One Binary Output (2 Amp Relay SPDT + Override) Contact Ratings: 2 Amp Resistive @ 277 Vac 2 Amp Magnetic
More informationRobus 600/1000. Programmable functions using the Oview programmer. STF ROBUS Rev00 Firmware: RF02
Robus 600/1000 Programmable functions using the Oview programmer STF ROBUS 600-1000 Rev00 Firmware: RF02 COMMON FUNCTIONS name This parameter enables the user to assign the automation with a name other
More informationALTAIR MA. D Vers. 03 CONTROL UNIT
D83 05-05-0 Vers. 03 CTROL UNIT Thank you for buying this product, our company is sure that you will be more than satisfied with its performance. This product is supplied with an Instruction Manual which
More informationTC 34 MICROPROCESSOR-BASED DIGITAL ELECTRONIC PULSE COUNTER. OPERATING INSTRUCTIONS Vr. 02 (ENG) - cod.: ISTR-MTC34ENG02
TC 34 MICROPROCESSOR-BASED DIGITAL ELECTRONIC PULSE COUNTER INDEX 1 INSTRUMENT DESCRIPTION 1.1 GENERAL DESCRIPTION 1.2 FRONT PANEL DESCRIPTION 2 PROGRAMMING 2.1 SET POINT PROGRAMMING 2.2 PARAMETERS PROGRAMMING
More informationELECTRONIC ROTARY GEAR MOTOR SERIES SED (AR2...SE )
ELECTRIC ROTARY GEAR MOTOR SERIES SED (AR2...SE ) INSTALLATI AND OPERATING INSTRUCTIS 1 GENERAL FEATURES 2 2 TECHNICAL DATA 3 3 INSTALLATI 3 ELECTRIC CNECTIS 5 CALIBRATI 5 5.1 ENDSWITCHES 5 5.2 AUXILIARY
More informationSUNDIAL Light Dimmer. User's Manual
Light Dimmer User's Manual 1. PRECAUTIONS Although fuses at the input and outputs of the controller protect its circuits in case of an overload or overvoltage, we recommend installing an additional protection
More informationWireless multizone receiver RDE-MZ6
s 1 428 Wireless multizone receiver RDE-MZ6 for floor heating / zone heating systems Mains-powered RDE-MZ6 multizone wireless receiver (AC 230 V) DIN rail mounting 2-position control with On/Off output
More informationDatasheetDirect.com. Visit to get your free datasheets. This datasheet has been downloaded by
DatasheetDirect.com Your dedicated source for free downloadable datasheets. Over one million datasheets Optimized search function Rapid quote option Free unlimited downloads Visit www.datasheetdirect.com
More informationPRO Professional Radio Control Series Applications
204 205 Ready to Use Remote Control 4, 8/16 Channel Systems Range: Up to 200 metres at 433MHz Up to 1,000 metres at 433MHz NB Relay Outputs: Momentary, Latching, Timed Receiver IP65 Applications Lighting
More informationConnection of Embedded Generating Plant up to 5MW
Engineering Recommendation No.3 of the Electricity Distribution Code Connection of Embedded Generating Plant up to 5MW Version 1.0 30th November 2005 Prepared by: Al Ain Distribution Company, Abu Dhabi
More informationHL 675 Data / Impulse Transmitter set User Manual
HL 675 Data / Impulse Transmitter set User Manual Version 02/2015 TAGHeuer Timin Page 1 / 8 1. Global The Set HL 675 is ideal for transferring Timing Data and Impulses. Its 500mW emitting power and its
More informationMicrowave barrier for perimeter protection at long range. Installation manual
Microwave barrier for perimeter protection at long range. Installation manual INDEX 1 COMPONENTI PRINCIPALI Pag. 3 2 ASSEMBLAGGIO POZZETTO Pag. 5 POSIZIONAMENTO POZZETTO Pag. 6 3 ALLINEAMENTO COLONNE Pag.
More informationIMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION
INSTALLATI INSTRUCTIS Model: RB-G-K10 IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIS BEFORE BEGINNING INSTALLATI The Miller Edge RBand Monitored Gate Edge Transmitter/Receiver system is intended to provide
More informationCANOPY LIGHT CANOPY LIGHT SAVE MORE - SEE MORE
CANOPY LIGHT CANOPY LIGHT SAVE MORE - SEE MORE Our Mission Is to reach the Goal Together with the Customer HTLUXC-100 High Brightness 13280 Lm. Long life 60000 h CANOPY LED LIGHT 100W Tecnologia LED Giapponesi
More informationIntegrated Servo Motor UCS57
Integrated Servo Motor Introduction is a new generation of high performance digital integrated servo drive motor, which is a series of low voltage AC servo products integrated with AC servo motor and drive
More informationIMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION
INSTALLATI INSTRUCTIS Models: RB-G-K10, RB-TX10 IMPORTANT: THIS DEVICE MUST BE PROFESSIALLY INSTALLED READ AND UNDERSTAND ALL INSTRUCTIS BEFORE BEGINNING INSTALLATI The Miller Edge RBand Monitored Gate
More informationCONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology
Instruction Bulletin 63249-420-283A4 08/2009 Wall Mount Occupancy Sensor SLSWPS1500, SLSWUS1500, SLSWDS1500 INTRODUCTION Wall Mounted Occupancy Sensors are Class 2 devices ideal for use in business or
More informationBEA s digital inductive single loop solution
BEA s digital inductive single loop solution Matrix2-S With more standard features than any other loop detector on the market, the Matrix2-S has the flexibility, compatibility and performance to maximize
More informationSOLID STATE HOUR METERS & COUNTERS 7 0 0 S E R I E S A p p l i c a t i o n s A wide variety of industrial and commercial applications, including scheduled maintenance, warranty and leasing for medical
More informationUSER MANUAL Z-10-D-OUT. Via Austria, PADOVA ITALY. Tel Fax
USER MANUAL Z-10-D-OUT SENECA s.r.l. Via Austria, 26 35127 PADOVA ITALY Tel. +39.049.8705355 8705359 Fax. +39.049.8706287 Web site: www.seneca.it Technical assistance: supporto@seneca.it (IT), support@seneca.it
More informationFuseless Capacitor Bank Protection
Fuseless Bank Protection Minnesota Power Systems Conference St. Paul, MN. November 2, 1999 by: Tom Ernst, Minnesota Power Other Papers of Interest Presented at Western Protective Relay Conference, Oct.
More information118, 128, KEELOQ REMOTE CONTROL SYSTEMS, 12 / 24Vdc,
Complete Remote Control System 1 4 Channel Remote Control Systems 12 or 24Vdc Supply AM / FM Remote Receiver Decoder High Security Protocol Easy Learn Tx Encoder Feature Easy Installation via Screw Terminals.
More informationInverter. Speed Control Motors. Standard AC Motors A-195. Standard AC Motors Intro duction
Standard AC Speed Control FE1/FE2 Standard AC Intro duction Induction Reversible Electromagnetic Brake Right-Angle Gearheads FE1/FE2 AC Speed Control Brake Pack SB5W US ES2 FE1/FE2 Watertight, Dust-Resistant
More informationwith Light Level, Isolated Relay and Manual On features
DT-200 version 3 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On features SPECIFICATIONS Voltage... 18-28VDC/VAC Current Consumption... 25mA Power Supply...WattStopper
More informationDMTME-96 2CSG133030R4022 M DMTME-I Operation and assembly instructions 2CSG163030R4022 M CSG445001D0202
DMTME-96 2CSG133030R4022 M204675 DMTME-I-485-96 2CSG163030R4022 M204685 2CSG445001D0202 GB Operation and assembly instructions DMTME-96: three-phase multimeter for panel mounting, used also in singlephase
More informationERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions
ELECTRONIC FAN SPEED CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5
More information05/09/2012
17.5 mm EMER8 Part number 88829198 Multifunction or mono-function Multi-range (7 ranges) Multi-voltage or single voltage Screw terminals LED status indicator (1 voltage present LED, 1 timer ON LED) Option
More informationIMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED. READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION.
INSTALLATI INSTRUCTIS Model: RB-G-K10 IMPORTANT: THIS DEVICE MUST BE PROFESSIALLY INSTALLED. READ AND UNDERSTAND ALL INSTRUCTIS BEFORE BEGINNING INSTALLATI. The Miller Edge RBand Monitored Gate Edge Transmitter/Receiver
More information500mW WIRELESS PHOTOCELL HL3-5x User s Manual Version 11/2017
500mW WIRELESS PHOTOCELL HL3-5x User s Manual Version 11/2017 X:\20-THHQ\Timing\Team\PRODUITS\TAG Heuer Professional Timing\HL3-5x\Mode d'emploi\en\sts_hl3-5x_en.doc22.11.2017 Page 1 / 16 1. Description
More informationSRC-110 Series Zone Controllers with Modbus RTU
Product sheet CT2.142 Type SRC-110-MOD SRC-110 Series Zone Controllers with Modbus RTU The SRC-110 series controllers have been designed for zone heating and cooling control. The controllers have 3 analogue
More informationENCODING PHOTOCELLS MF6
ENCODING PHOTOCELLS MF6 Wall-mounted encoding photocells, 180 rotation and range of up to 20 mt. The code for the transmitted signal, which must be set at the time of installation, makes it possible to
More informationT C X O and Logic: TTL / HCMOS V C T C X O Wave Form: Square Wave
T C X O and Logic: TTL / HCMOS V C T C X O Wave Form: Square Wave Product Summary: SQUARE MERCURY Since 1973 TCXO VCTCXO Available Frequency Range Output Wave Form: Square Wave Package size (mm), L x W
More informationInstallation and start up instructions. Paralleling relay type HAS-111DG uni-line G (UK) Synchronisation of generator to busbar
Installation and start up instructions Paralleling relay type HAS-111DG uni-line 4189340146G (UK) Synchronisation of generator to busbar Setting of phase angle difference Setting of frequency and voltage
More information3301PF INSTALLATION AND OPERATING INSTRUCTIONS
330PF INSTALLATI AND OPERATING INSTRUCTIS IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATI INSTRUCTIS DO NOT ATT TO INSTALL OR OPERATE INTRODUCTI This SKYTECH remote control system was developed to provide
More informationThe Best Relaytion. Cradle Relay S Rev. B EC-JM ECOC: JM10 1. Aug. 04
The Best Relaytion Cradle Relay S 108-98014 Rev. B EC-JM00-0009-03 ECOC: JM10 1. Aug. 04 Hand solder and plug-in relay, for DC operation, non-polarized, non-latching Features Stronger magnet system and
More informationASSEMBLY AND INSTALLATION INSTRUCTIONS
T0412 / T0413 ASSEMBLY AND INSTALLATION INSTRUCTIONS WARNING: NOTES: 1. Before installing, consult local electrical codes for wiring and grounding requirements. 2. READ AND SAVE THESE INSTRUCTIONS. Hardware
More informationResidual instantaneous overcurrent protection function block description
Residual instantaneous overcurrent block description Document ID: PRELIMINARY VERSION User s manual version information Version Date Modification Compiled by Preliminary 30.10.2009. Preliminary version,
More informationINSTALLATION & MAINTENANCE INSTRUCTIONS ON THE PCR-5 4 CHANNEL REMOTE CONTROL SYSTEM
TM TM LIGHTING INSTALLATI & MAINTENANCE INSTRUCTIS THE PCR-5 4 CHANNEL REMOTE CTROL SYSTEM FEATURES Easy to Install Approved to U563 & CSA C22.2 No. 218-1-13 Pending Remote Control Operation from PCT-5
More informationDialight LED Obstruction. Technical Specification Sheet - Medium Intensity Red
Dialight LED Obstruction Technical Specification Sheet - Medium Intensity Red Obstruction Red Beacon Vigilant LED Beacon Medium Intensity (Red) FAA L-864 / ICAO Medium Type B+C Mechanical Information:
More informationDis. N. LIBRETTO DI ISTRUZIONI INSTRUCTIONS NOTICES D INSTRUCTION ANLEITUNG FOLLETO DE INSTRUCCIONES HANDLEIDING
I LIBRETTO DI ISTRUZIONI MONOFASE PER SCORREVOLE NYOTA 115 - FUNZIONE PASSO PASSO - UOMO PRESENTE - APERTURA PEDONALE - LUCE DI CORTESIA - DIAGNOSTICA A LED LUMINOSI - SPIA DI SEGNALAZIONE DELLO STATO
More informationMulti-rate Gigabit Ethernet & Fibre Channel SFP Transceivers with Digital Diagnostics
Multi-rate Gigabit Ethernet & Fibre Channel SFP Transceivers with Digital Diagnostics TRPEG-EG Single Mode Pb Product Description The TRPEG-EG SFP series of multi-rate fiber optic transceivers with integrated
More informationOC-12/STM-4 SFP Multimode Transceivers with Digital Diagnostics
OC-/STM- SFP Multimode Transceivers with Digital Diagnostics TRPAMM Product Description The TRPAMM SFP fiber optic transceivers with integrated digital diagnostics monitoring functionality provide a quick
More informationL Rev. 04/05/03
L8542839 Rev. 04/05/03 CENTRALE DI COMANDO CONTROL UNIT STEUEREINHEIT CENTRALE DE COMMANDE CENTRAL DE MANDO CENTRALKA STEROWANIA Libro istruzioni Operating instructions Betriebsanleitung Livret d instructions
More information1: White buttons Used by the user on a daily basis. 2: Grey buttons Used only upon first startup.
Fig. 1 Lock/ unlock 30 1000 Light 1 100 300 zone 1 Learn actual lux LED 600 2000 0,4 0,6 0,8 1,0 1,2 Time 1 Light 2 zone 2 1,4 1,6 Factor of lux zone 1 Pulse 2min 5min Time Time 2 10min 15min 30min 1 2
More informationCURRENT/FREQUENCY CONVERTER S 104
CURRENT/FREQUENCY CONVERTER S 104 The S104 complies the electromagnetic compatibility prescriptions based on the 89/366/EEC directive. Reference norms: EN 50081-2 Industry environment emission norm EN
More informationWIDE RANGE OF VIDEO SCREEN SOLUTION FOR OUTDOOR AND INDOOR PROJECTS:
led video screen INTRODUCTION: ARENA LUCI has been working in the professional lighting area for over thirty years with production department in Castel Goffredo (Mantova) ITALY. The ARENA LUCI brand is
More informationThe full glazed window. More transparency than ever.
The full glazed window. More transparency than ever. And then, as if enchanted, the excesses vanish, the superfluous disappears. From then on only elegance remains.nothing but elegance. The full glazed
More informationINSTALLATION and OPERATION INSTRUCTIONS. FOR FiberLink BI-DIRECTIONAL AMPLIFIER WITH DIVERSITY MW-FBDA-800AB-50W-DIV
INSTALLATION and OPERATION INSTRUCTIONS FOR FiberLink BI-DIRECTIONAL AMPLIFIER WITH DIVERSITY MW-FBDA-800AB-50W-DIV Page 1 of 15 TABLE OF CONTENTS PARA No. PARAGRAPH PAGE No. 1. OVERVIEW 3 2. COMPONENT
More informationINDEX 1 - PRODUCT FEATURES
VELA-RX 220V 1000W Control unit for 1 device with max power 1000W. 110/240 VAC power supply, integrated RX 433.92 MHZ ISM, 2 wired inputs settable with button or switch. Presence simulation function. 1
More informationSilencer Series Brushless Controllers
Silencer Series Brushless Controllers BDP-Q2-50-10, BDP-Q2-20-10 2-quadrant speed controller for brushless motors GENERAL Instruction Manual The BDP-Q2-50-10, BDP-Q2-20-10 controllers are 2-quadrant speed
More informationRI-R11 series RI-R11D series
RIR series RIRD series INSULATI MITORING VERSIS FOR NETWORKS dc MAX V GENERAL MODELS The devices allow perent mitoring of insulati of electrical networks in directcurrent current isolated earth (IT networks).
More informationSAFETY PRECAUTIONS GENERAL INFORMATION
Form No. 102831 SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Internet Address: http://www.hytec.com Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800)
More informationFMR. Ultra Line FEEDER MANAGER RELAY
Ultra Line FEEDER MANAGER RELAY Protective Functions F49 : One Thermal Image element F50/51/67 : Three levels for phase overcurrent independentely programmable as directional or non directional F50N/51N/67N
More informationSeries 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual
THE HIGH PERFORMANCE COMPANY Series 70 Hold 1 sec. Hold 1 sec. FOR MORE INFORMATION ON THIS PRODUCT AND OTHER BRAY PRODUCTS PLEASE VISIT OUR WEBSITE www.bray.com Table of Contents 1. Definition of Terms.........................................2
More informationWEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K
O P E R A T I N G I N S T R U C T I O N S WEL-200 TM W I R E L E S S E D G E L I N K 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com
More informationThe Best Relaytion. Cradle Relay W Rev. B EC-JM ECOC: JM10 1. Aug. 04
The Best Relaytion Cradle Relay W 08-9803 Rev. B EC-JM00-0009-03 ECOC: JM0. Aug. 0 Hand solder and plug-in relay, for AC operation, non-polarized, non-latching Features highly reliable great variety of
More informationPositive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Contact expander module for increasing the number of available contacts Approvals Unit features Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous
More informationProtection Relays. U-MLEs-PLv. Ultra Line. DC SUBSTATION PROTECTIVE RELAY (double voltage Line Test) 32, 45, 49, 64, 76, 79, 80
Ultra Line DC SUBSTATION PROTECTIVE RELAY (double voltage Line Test) 3, 45, 49, 64, 76, 79, 80 D.C. Feeder protection relay with setting parameters programmable locally or via serial communication. Suitable
More informationIsolation Transformer Series
Isolation Transformer Series Unit Shown With Options ITS Series - Isolation Transformer Series The La Marche Isolation Transformer Series (ITS) is designed for installation in industrial and harsh environment
More informationPULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL
SPECTRADYNAMICS, INC PD5-RM-B PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2. Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 www.spectradynamics.com
More informationHL 670 Data / Impulse Transmitter set User Manual. Version 07/2010
HL 670 Data / Impulse Transmitter set User Manual Version 07/2010 1. Global The Set HL670 is ideal for transferring Timing Data and Impulses. Its 500mW emitting power and its licence free frequency range
More informationLED Driver. Xitanium 42W A 52V LE+TE INT XI042C080V052RNP1. Specifications. Wiring Diagram. Enclosure
LED Driver Xitanium 42W 0.5-0.8A 52V LE+TE INT XI042C080V052RNP1 Specifications Input Voltage (Vrms) Output Power (W) Output Voltage (V) Output Current (A) Efficiency@ Max. Load and 70 C Case The Philips
More information