WIRELESS DIMMER FOR HEATING
|
|
- Shannon Stevenson
- 5 years ago
- Views:
Transcription
1 TELECO AUTOMATI SRL - Via dell Artigianato, Colle Umberto (TV) ITALY TELEPHE: FAX: This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights WIRELESS DIMMER FOR HEATING Wireless dimmer for resistive and infrared heaters. Possibility to dimming from 0% to 100%. Inputs for external wired push-button and wired PIR sensor. Automatic room s temperature control via external wired temperature probe. Compatible with all TV-Link transmitters. 2 Models available with extended range from 120Vac to 230Vac: TVHET868A04: up to 4000W - to control 1 Heater of 4000W - to control 2 Heater of 2000W each TVHET868A06: up to 6500W - to control 1 Heater of 6500W - to control 2 Heater of 3200W each 4.5cm Functions by: Wireless Transmitters : - - Dimming from 0% to 100% - OFF Push-Button : 19.5cm TVHET868A04 TVHET868A Dimming from 0% to 100% - OFF PIR Wired and Wireless : 20cm - at 100% TECHNICAL SPECIFICATIS Model/Code Power supply Maximum total load Dimensions (mm) TVHET868A04 120/230 Vac~ 4000W 195 x 200 x 75 50/60Hz TVHET868A06 120/230 Vac~ 6500W 195 x 200 x 75 50/60Hz dimmer Infrared and resistive heaters 1
2 Infrared and resistive heaters Wiring Diagram INPUT STATUS - LED when ACTIVE LED ERROR - Fix : overload - Blinking : overtemperature RADIO TRANSMISSI - When blinking a radio trasmission is received Temperature trimmer (see par.8) DANGER Hi-Voltage Safety Lo-Voltage Zone DIP-Switch (see par.1) OUTPUT Level Temp probe Optional P.S. Power supply E SINGLE OUTPUT LOAD 6500W max Safety Low Voltage Input T1 T2 T3 COM P1 - Memorize Tx. P2 - Delete Tx. P3 - Function (see par.7) - When not used, close cable glands with their caps. - Hi-Voltage board, risk of electric shock. - Never touch the board outside the safety zone. 2
3 1 - DIP Switch Function DIP SWITCH PIR time is 30 minutes PIR time is 15 minutes - Use DIP1 to set the PIR time from 15min. to 30min. This function is active only when DIP.2 is enabled. - Use DIP2 to able and disable the PIR commands. Both wireless and wired PIR will be excluded. - Use DIP3 to select Resistive Heater or Infrared Heater When Infrared Heater is selected (DIP3 in position) and a command is received, the TVHET868A06 starts in soft mode, for extending the lifetime of the heater. PIR enabled Infrared Heater PIR disabled Resistive Heater Transmitters Memorization Memorisation of 7-channel transmitters 100% 75% 50% Min Dim+ Dim- OFF Function available only for 7 or 42ch. transmitter P1 one time it 1 - the push button P1 once it ; the buzzer will sound a continuous beep. 2 - During the beep sound press a push button of the 7-channel transmitter which has to be memorised; the memorization is indicated by the intermittent sound of the buzzer. All the push-buttons of the transmitter are automatically memorized with a preset configuration as in the above drawing. 3
4 To change the preset levels of the 7-channel transmitter ( CH1, CH2, CH3, CH4 ) CH1 CH2 CH3 CH5 CH6 Adjust CH4 CH7 5 sec. press press the button to be modified 1- one of the first four push button to be modified adjust new value 2- Adjust the new value with the two push buttons Ch5 and Ch6; press more than 5s 3- Hold the CH7 push button for 5 sec., after 5 sec. the load will turn on at the new value Memorization of 4 push-buttons transmitters with preset values The push buttons of the memorized transmitter will have the following functions: Preset Value: 2 times CH1: 100% CH2: 50% CH4: min CH4: Off 1- the push button P1 two times it the second one; the buzzer will make one beep and then sound continuously. 2 - During the beep sound press a push button of the transmitter which has to be memorised; the memorization is indicated by the intermittent sound of the buzzer. All the push-buttons of the transmitter are automatically memorized with a preset configuration as in the above drawing Memorization of one transmitter push-button with On/Off/Dim function With short impulses turn the load on and off; keeping it pressed to dim UP or DOWN the load. 3 times Function available for all type of transmitters 1- the push button P1 three times it the third one, the buzzer will make a beep each time and then sounds continuously. 2 - During the beep sound press the push button of the transmitter which has to be memorised; the memorization is indicated by the intermittent sound of the buzzer. 4
5 2.4 - Memorization of 3 push-buttons transmitters The push buttons of the memorized transmitter will have the following functions: CH5 dim UP, CH6 dim DOWN and CH7 turns /OFF the load. 4 times CH5: Dim + CH6: Dim - CH7: On/Off 1- the push button P1 four times it the fourth one, the buzzer will make a beep each time and then sounds continuously. 2 - During the beep sound press the push button of the transmitter which has to be memorised; the memorization is indicated by the intermittent sound of the buzzer. All the push-buttons of the transmitter are automatically memorized with a preset configuration as in the above drawing Memorization of one transmitter push-button with function The push-button memorised with On function turns on the last output level and does any time it is pressed. 5 times Function available for all type of transmitters 1- the push button P1 five times it the fifth one, the buzzer will make a beep each time and then sounds continuously. 2 - During the beep sound press the push button of the transmitter which has to be memorised; the memorization is indicated by the intermittent sound of the buzzer Memorization of one transmitter push-button with OFF function The push-button memorised with Off function turns off the load and does OFF any time it is pressed. 6 times Function available for all type of transmitters 1- the push button P1 six times it the sixth one, the buzzer will make a beep each time and then sounds continuously. 2 - During the beep sound press the push button of the transmitter which has to be memorised; the memorization is indicated by the intermittent sound of the buzzer. 5
6 2.7 - PIR Transmitters Memorization The wireless movement sensors (PIR) can be used to automatically activate the heater. 7 times 1- the push button P1 seven times it the seventh one, the buzzer will make a beep each time and then sounds continuously. 2 - During the beep sound activate the sensor; the memorization is ndicated by the intermittent sound of the buzzer. 3 - To copy a function of transmitter push-button to a new transmitter The push button P3 is locate inside the transmitter (see transmitter manual). The new transmitter will have the same functions of the transmitter used for its memorization. P3 Function available for all type of transmitters 1- the button P3. The enabled receiver sound continuously. 2- Within 5 sec. press a pushbutton of the already memorized transmitter of which the function has to be copied. The buzzer will interrupt the sound for 1 sec., and then carry on for 5 sec. 3- During the sound press the push-button of the new transmitter which has to be memorised; the memorization is indicated by the intermittent sound of the buzzer. P.S. When a 7 channel transmitter is copied, also its levels will be copied into the new one. 6
7 4.1 - To delete a transmitter Once 1- the push button P2 once it, the buzzer will sound slowly and intermittently. 2- During the sound press the push-button which has to be deleted; the deletion is indicated by the continuous sound of the buzzer To delete all transmitter 2 times 10s 1- the push button P2 two time it, the buzzer will make one beep and then sound quickly and intermittently. 2- Hold the push button for 10 sec., after this the buzzer will sound continuously by indicating that the whole memory has been cancelled To delete a transmitter from transmitter : P3 function P3 1- three times the button P3 placed inside of the transmitter. The buzzer will sound intermittently and slowly. 2- During the intermittent sound press the push button which is to be deleted; the deletion is indicated by the continuously sound of the buzzer. 5 - Memory Activation/Deactivation of the last value of the Load Memory function activated: when you control the load in /OFF mode, the load will turn-on with the same values it had before turning-off. Memory function deactivated: when you control the load in /OFF mode, the load will turn-on always at 100%. P.S.: The memory function is not possible when using the 7-ch. transmitter. 1- Push the push buttons P1+P3 and Hold - 1 beep : the function is activated. - 2 beep : the function is deactivated. 7
8 6- To set the minimum level for the Load This function allows to set the minimum level that can be reached by the load. the push buttons P1+P2 together and Hold : - 16 beep : the function is activated. - 3 beep : the function is deactivated. 1- Regulate the minim desired level 2- the push buttons P1 + P2 together it. The buzzer makes a beep. To reset the level to the default value, press again the push buttons P1 + P2 together it. The buzzer makes a beep. P.S.: Set a different value of the min. load level only with resistive loads (see DIP-Swith function on par. 1) 7 - Wired Input Function The receiver has three wired input (safety low votage): - T1: push-button input to /OFF and DIM the load For both the T1 and T2 push-button the function is: Short impulse (< 400mS) = /OFF Long impulse (> 400mS) = adjusting upgrade or grade. - T2: PIR Input to the load at 100% - T3: Not Used Temp Optional input with LED indicator T1 T2 T3 Push-Butt PIR input Not Used Safety Low Voltage 100m wire guaranteed 8
9 8 - Automatic Room Temperature Control It is possible to set the room temperature with the Automatic Temperature Control function. The control function works only when the temperature proble is connected to the unit. Control Disabled When activated, sounds one beep Temperature regulation S1 S2 S To activate the temperature control, turn the trimmer clockwise (see S2 position). At the activation the unit sounds one beep. When the control function is activated and the room temperature get higher than the confort temperature: - the dimmer will turn-off - the unit will exclude the next radio transmitter commands. - the unit cominicates that error with a beep. - To deactivate the temperature control, turn the trimmer to the left position S1 To bypass the temperature control keep press one of the first 4 push-button for about 7 seconds (only with 7-ch transmitters). 9 - Errors during the memorizing or deleting If the code hasn t been memorised it could be due to the following reasons: - the code already exists in memory. - the memory is full. - the indexing procedure has not been correctly started up. If the code hasn t been cancelled it could be due to the following reasons: - the code doesn t exist in memory. Memory full or empty If the memory of the receiver is full or empty the buzzer will sound three times either during the memorization phase or after the reset of the receiver. 9
10 10 - Warning The subject appliance must be installed only by qualified technical personnel in compliance with the standards. All connections must be rated for a single-phase power supply of 230V. For the disconnection from the power line, use an all-pole switch with contact with an opening of at least 3,5mm. Only suitable materials for the connections must be used to guarantee insulation that complies with current standards on the subject of electrical safety. The receiver only carries out /OFF commands and all safety devices required by the system must be prepared a part. Ground connection must be provided separately. In the connection to power line and to outputs follow the indications of line and neutral. Connections wire must have a section suitable to the applied load. In the view of a constant development of their products, the manufacturer reserves the right for changing technical data and features without prior notice. The appliance is not intended for use by people (including children) with reduced physical, sensorial or mental facilities, or with a lack of experience or knowledge, unless they are supervised by a person responsible for their safety or instruction concerning the use of the appliance. Children must be supervised to ensure that they do not play with the appliance. Must necessarily be fitted the cable glants provided or the cable glants with the same mechanical and safety characteristics. The power cable must have a nominal characteristic of 90 C temperature T. The main power supply must have connecting cables with a cross section suitable for the load applied to the relays. The connecting cables of the main power supply and of the loads must have adequate section and electrical isolation; their installation must comply with the standards on electrical systems. The following table shows (roughly) the typical values of maximum resistance for km and maximum tolerable current of a copper electrical wire, according to its section: Section (mm2) R (ohm/km) Max. current (A) If the power cable is damaged, it must be replaced by the manufacturer or by the technical assistance service or by a similarly qualified person, in order to avoid all the risks. Use the appliance only with loads in which the functioning isn t dangerous in the case that they remain permanently activated. The device s signal reception could be disturbed by several factors such as: - the presence of electrical frequency noise being transmitted by other appliances working in the same environment and on the same frequency. - appliances installed in metal containers or shielded from metal parts; only use containers made of plastic TECHNICAL SPECIFICATIS -Power supply 120/230 V 50/60Hz - Max Output Power 6500W at 230Vac~ 3400W at 120Vac - Reception frequency MHz - Operating temperature range -20 / +80 C -The maximum number of transmitters that can be memorized is
11 11
Motor 1- GENERAL DESCRIPTION
1- GENERAL DESCRIPTI TELECO AUTOMATI SRL - Via dell Artigianato, 16-31014 Colle Umberto (TV) ITALY TELEPHE: ++39.0438.388511 FAX: ++39.0438.388536 This document is the property of Teleco Automation Srl
More informationThis document is the property of Teleco Automation Srl who reserves all reproduction and copying rights
1- GENERAL DESCRIPTION Electronic for the remote control of tubular motors for roller blinds, rolling shutters, doors with limit switch inside or outside the motor, radio receiver section with transmitter
More informationV~ DIMMER WITH BUILT-IN RADIO RECEIVER AND DALI OUTPUT FOR CONTROL BALLASTS AND LAMPS. Push-button input for manual controls.
MR RESISTOR 110-230V~ DIMMER WITH BUIT-I RADIO RECEIVER AD DAI PUT FOR CTRO BAASTS AD AMPS. Push-button input for manual controls. Product code TVDMA868A01 20 slaves, 868.3Mhz TVDMA868A02 64 slaves, 868.3Mhz
More informationEBDSPIR-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features
Product Guide EBDSPIR-AT-DD RF ceiling PIR presence detector DALI / DSI dimming Overview The EBDSPIR-AT-DD is a passive infrared (PIR) motion sensor combined with two output channels capable of controlling
More informationConnect + compatible
Connect + compatible Looking for a quick setup up guide? There is lots of useful information in this book, but if all you are after is quick set up look for the following headings in this book 1) Setting
More informationDigital Electronic Thermostat With RF
RT300RF Manual Altech 005_89 06/05/2014 08:56 Page 1 Digital Electronic Thermostat With RF Instruction Manual Model No ALTHC015 RT300RF Manual Altech 005_89 06/05/2014 08:56 Page 2 2 ALTHC015 INSTRUCTION
More informationAT-SL-DDR & AT-SL-DDR-SA
AT-SL-DDR & AT-SL-DDR-SA Product Guide Slim-line RF DALI/DSI + relay controller Overview The AT-SL-DDR and AT-SL-DDR-SA are wireless controllers with two output channels capable of controlling incandescent,
More informationIRRIGATION 810-3R RECEIVER GUIDE
IRRIGATION 810-3R RECEIVER GUIDE Pg. 2 HOT SHOT OVERVIEW 3 RECEIVER FUNCTION SWITCH SETTINGS 4 RECEIVER INDICATOR LIGHTS 4 SUPERVISION FEATURE 5 RECEIVER HOOKUP TO ENGINE DRIVEN WELL 6 RECEIVER HOOKUP
More informationINDEX 1 - PRODUCT FEATURES
VELA-RX 220V 1000W Control unit for 1 device with max power 1000W. 110/240 VAC power supply, integrated RX 433.92 MHZ ISM, 2 wired inputs settable with button or switch. Presence simulation function. 1
More informationAT-SL-DDR & AT-SL-DDR-SA
Product Guide AT-SL-DDR & AT-SL-DDR-SA Slim -line RF DALI/DSI + relay controller Overview The AT-SL-DDR andat-sl-ddr-sa are wireless controllers with two output channels capable of controlling incandescent,
More informationT.CO.O - R.CO.O Double
T.CO.O - R.CO.O Double Transceiver system for mechanical safety and 8,K resistive edges RECEIVER R.CO.O Double in box TRANSMITTER T.CO.O Double Cod. 006767 Bidirectional communication RECEIVER R.CO.O Double
More informationMini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version
MR9 WARRANTY Steffes Corporation ( Steffes ) warrants that the Steffes Power Line Carrier Mini Receiver is free from defects in materials and workmanship under normal use and service. Steffes obligation
More informationTCO6RX / TCO6TX. Transceiver system for mechanical safety and 8,2K resistive edges. Bidirectional communication
TCO6RX / TCO6TX Transceiver system for mechanical safety and 8,K resistive edges TRANSMITTER : TCO6TX RECEIVER : TCO6RX Bidirectional communication Notified Body Directive 98/7/EC EC ident. N 8 PRASTEL
More informationAT-SL-ADR & AT-SL-ADR/SA
AT-SL-ADR & AT-SL-ADR/SA RF 1-10V + relay controller Product Guide Overview The AT-SL-ADR and AT-SL-ADR/SA are wireless controllers with two output channels capable of controlling incandescent, fluorescent
More informationERONE CH RECEIVER
4 ERONE 433-4 CH RECEIVER MANUAL INSTALLATION SEL 2641 R433C4 SEL 2641 R433V4 Thank you for choosing a product Erone. You are recommended to read carefully this manual before installing the product. SUMMARY
More informationWireless multizone receiver RDE-MZ6
s 1 428 Wireless multizone receiver RDE-MZ6 for floor heating / zone heating systems Mains-powered RDE-MZ6 multizone wireless receiver (AC 230 V) DIN rail mounting 2-position control with On/Off output
More informationContents. English User Manual Regulators
Contents Safety warnings Page 28 Technical specifications Page 28 Description of instrument Page 31 Electrical connections Page 31 Glossary Page 32 Operation Page 37 Setting the regulation parameters Page
More information1: White buttons Used by the user on a daily basis. 2: Grey buttons Used only upon first startup.
Fig. 1 Lock/ unlock 30 1000 Light 1 100 300 zone 1 Learn actual lux LED 600 2000 0,4 0,6 0,8 1,0 1,2 Time 1 Light 2 zone 2 1,4 1,6 Factor of lux zone 1 Pulse 2min 5min Time Time 2 10min 15min 30min 1 2
More informationOPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1
OPERATING INSTRUCTIONS ARE ON PAGE 5 RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1 This Programmable Ravenheat R/F controlled room Thermostat RVHT 2, consists of 2 items: a Mobile Transmitter
More informationUniversal Radio Cord Dimmer Order No.: Function
Order o.: 0335 0 a) b) Function The permits radio-operated control of lighting fixtures. The device permits switching (short actuation) or dimming (long actuation) of the lighting. The dimmer is operated
More informationELECTRONIC PANEL MC15
ELECTRONIC PANEL MC15 GB Single-phase electronic control unit for the automation of sliding gates, doors and barriers with incorporated radio receiver. Possibility of integrating a radio system with the
More informationFixture Built-in Sensor Daylight Harvest Version
Fixture Built-in Sensor Daylight Harvest Version Model: HC419VRC /DH Infrared remote receiver Detection area Hold-time Daylight sensor Buzzer Sensor antenna Photocell Installation hole (4.2mm) 4.2 45 Stand-by
More informationModel: &
600A True RMS Digital Clamp Meter Model: 72-3097 & 72-3099 1 CONTENTS Page Number Details 3 Important Safety Information 4 Product overview 4 Key Functions 5 General Specification 5 Electrical Specification
More informationIstructions. Central control board for electromechanical gearmotors HERCULES 24V
Central control board for electromechanical gearmotors HERCULES 24V 1 2 Attention! The present user s manual is designed for personnel skilled in installation, not for the final user; the electrician is
More informationSmart-house Dimmer Power dimmer up to 500W Type SH2D500W230
Smart-house Dimmer Power dimmer up to 500W Type SH2D500W230 Universal dimmer switch for R, L, C up to 500W and LED loads Automatic load detection for L, R, C loads Integrated heat sink for temperature
More informationUSER S MANUAL. This manual must be considered an integral part of the projector. The user must read this manual before using the projector
575W HMI Scan light ZIPPER 575 USER S MANUAL This manual must be considered an integral part of the projector. The user must read this manual before using the projector AUTHORISED AND QUALIFIED PERSONNEL
More informationWireless Control Systems
Wireless Control Systems Leading the way in intelligent automation contents Range Overview Typical Installations Transmitters Combined Modules Receivers Accessories Programming Switching & Dimmer Functions
More informationLOM-15 CD-LOM15-01 PRODUCT OVERVIEW. Product. Description. Specifications SKU: LOM-15. Duplex Receptacle
CD-LOM15-01 LOM-15 Product Duplex Receptacle Description The Evolve Wall Mounted Outlet is a component of the Evolve lighting control system and is wired in place of a standard receptacle in any existing
More informationEBDHS-MB-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features
Product Guide EBDHS-MB-AT-DD RF ceiling PIR presence detector DALI / DSI dimming Overview The EBDHS-MB-AT-DD is a passive infrared (PIR) motion sensor combined with two output channels capable of controlling
More informationEBDHS-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features
Product Guide EBDHS-AT-DD RF ceiling PIR presence detector DALI / DSI dimming Overview The EBDHS-AT-DD is a passive infrared (PIR) motion sensor combined with two output channels capable of controlling
More informationUser Manual 3X300 DIMMER MODULE DM03B02KNX
User Manual 3X300 DIMMER MODULE DM03B02KNX 1/29 Index 1.... Presentation of the Dimming functions 3 2.... Configuration and param. of the Dimming functions 5 3.... Physical addressing 29 2/29 1. Presentation
More informationRadio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch
Radio Touch Order no.: 2880 xx Operation and installation instructions 1 Safety instructions Electrical equipment must only be installed and assembled by a qualified electrician in accordance with the
More informationElectrical devices may only be mounted and connected by electrically skilled persons.
Order No. : 5490.. Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible.
More informationNote: A 6-button hand control XX or X is required to access service mode.
PROGRAMMING GUIDE FOR CEILING LIFT 910XXXX, 911XXXX, 912XXXX, 913XXXX, 923XXXX, LDXXXX, LFXXXX V4, V4i, V10, MAXI SKY 600, MAXI SKY 1000, VOYAGER DUO, V5 DUO 1. User Service Mode page 2 2. Technical Service
More informationElectrical devices may only be mounted and connected by electrically skilled persons.
Art. No. : FM..1561.07.. Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible.
More informationFL ballasts Electronic dimming. PCA T8 ECO lp Y II, W ECO T8
T8 PCA T8 ECO lp Y II, 18 58 W ECO T8 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DALI or DSI signal,
More informationSupply 12Vdc nominal (9 Vdc minimum, 14,5Vdc maximum ) Max Current Drain. from a , V Carrier Frequency
MIX400 48 CHANNELS WIRELESS RECEIVER ON 8 OUTPUTS TECHNICIAN MANUAL ENGLISH DESCRIPTION Mix 400 is a 48 channel universal wireless receiver, memorizable and free assignable on 8 open-collector outputs.
More informationMounting Instructions / Manual MV1171
Mounting Instructions / Manual MV1171 POWER FACTOR Controller ESTAmat MH-N Vishay Electronic GmbH ESTA Capacitors Division Revision: 19-April-2011 Hofmark-Aich-Strasse 36 84030 Landshut, Germany Phone
More informationENVIRONMENTAL PROTECTION
ENVIRONMENTAL PROTECTION Do not dispose of this product with the normal household waste at the end of its life cycle. Return it to a collection point for the recycling of electrical and electronic devices.
More informationServomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16
MZ Servomotor for butterfly valves VF, VFH delta-elektrogas.com EE157-01/16 MZ Servomotor Contents Description.... 2 Features........ 2 Functioning and application..... 3 Technical specifications......
More informationREV-201М OPERATING MANUAL MULTIFUNCTIONAL TWO-CHANNEL TIME DELAY RELAY. «NOVATEK-ELECTRO» Ltd Intelligent industrial electronics
Ltd Intelligent industrial electronics MULTIFUNCTIONAL TWO-CHANNEL TIME DELAY RELAY OPERATING MANUAL Review the Operating manual before using the unit. www.novatek-electro.com Store the unit in the operating
More informationTransmitter System USER S MANUAL. Light Series
Transmitter System USER S MANUAL Light Series Follow the indications and warnings given by the machine producer regarding the machine controlled by the radio remote control. The information contained in
More informationINSTALLATION & OPERATING MANUAL. AT 08 Analog Transmitter
INSTALLATION & OPERATING MANUAL AT 08 Analog Transmitter 2 SECTION I GENERAL INFORMATION The Model AT08 Analog Transmitters are ideal for use on systems having a full scale range of 10 mv, 20 mv, or 30
More informationUR200SI / UR200WE ENGLISH
ENGLISH Hersteller Wörlein GmbH Tel.: +49 9103/71670 Gewerbestrasse 12 Fax.: +49 9103/716712 D 90556 Cadolzburg Email. info@woerlein.com GERMANY Web: www.woerlein.com UR200SI / UR200WE ENVIRONMENTAL PROTECTION
More informationWIRELESS NETWORK USER MANUAL MHz RFT-868-REL Remotely Controlled Relay Switch
WIRELESS NETWORK USER MANUAL 868.3 MHz Remotely Controlled Relay Switch Device Specifications Max Switching Voltage: 250 VAC Max Switching Current: 10 A Max Switching Power: 2500 VA Power Draw in standby
More informationFL ballasts Electronic dimming. PCA T8 ECO lp Y, 3x18 W and 4x18 W ECO T8
T8 PCA T8 ECO lp Y, x18 W and x18 W ECO T8 Product description Processor-controlled ballast with y inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal, switchdim
More information1000TR. Instructions
1000TR ph Instructions CONTENTS 1. INTRODUCTION... 2 1.1 COMMON INTRODUCTION... 2 1.2 PARTS & ACCESSORIES... 2 2. INSTALLATION... 3 2.1 CASING... 3 2.2 MOUNTING... 3 2.3 ELECTRICAL INSTALLATION... 3 2.3.1
More informationBuilt-in receiver module
TT2N Built-in receiver module 0682 EN - Instructions and warnings for the Fitter IT - Istruzioni ed avvertenze per l Installatore FR - Instructions et recommandations pour l Installateur ES - Instrucciones
More informationSF Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications
Long Range Wireless Applications 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) The switch followers are a two way system designed to provide a quick and cost effective
More informationFL ballasts Electronic dimming. PCA T5 ECO lp Y, 3x14/24 W and 4x14/24 W ECO T5
T5 PCA T5 ECO lp Y, x1/ W and x1/ W ECO T5 Product description Processor-controlled ballast with y inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal, switchdim
More informationBU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS
INSTRUCTION MANUAL BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS 1/23 More information than that reported
More informationHuman Centric Lighting System
Human Centric Lighting System PIR HHC24 HHC23 HHC245 Circadian Rhythm sensor with Tunable white LED driver Lighting can reduce energy bills, it also can boost productivity and promote the wellbeing of
More informationDEUTSCH ITALANIO ENGLISH NORSK FRANÇAIS DANSK NEDERLANDS Hersteller UR8200
DEUTSCH ENGLISH FRANÇAIS NEDERLANDS ITALANIO NORSK DANSK Hersteller Wörlein GmbH Tel.: +49 9103/71670 Gewerbestrasse 12 Fax.: +49 9103/716712 D 90556 Cadolzburg Email. info@woerlein.com GERMANY Web: www.woerlein.com
More informationIMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION
INSTALLATI INSTRUCTIS Models: RB-G-K10, RB-TX10 IMPORTANT: THIS DEVICE MUST BE PROFESSIALLY INSTALLED READ AND UNDERSTAND ALL INSTRUCTIS BEFORE BEGINNING INSTALLATI The Miller Edge RBand Monitored Gate
More informationDialight Daylight Harvesting Sensor User Guide
Daylight Harvesting Sensor Dialight Daylight Harvesting Sensor User Guide Dialight Catalog Number: DLHU124UG2 1 Safety Instructions Dialight Daylight Harvester Sensor (DLH) User Guide READ AND FOLLOW ALL
More informationRADIOBAND V3 Programming & Installation Manual
RADIOBAND V3 Programming & Installation Manual Radioband V3 User s Manual Introduction The RadioBand system is designed for Automatic Gates, Commercial and Domestic door applications where a safety edge
More informationVHF Transceiver AR6201
VHF Transceiver AR6201 Operating Instructions Issue 2 / October 2010 Article No. 0618.764-071 Becker Flugfunkwerk GmbH Baden-Airpark B 108 77836 Rheinmünster Germany Telefon / Telephone +49 (0) 7229 /
More informationSmart Dupline Wireless dimmer with energy reading Type SHJWD200WExxx
Smart Dupline Wireless dimmer with energy reading Type SHJWD200WExxx Universal wireless dimmer up to 200 W for R, L, C load and LED lamps Wireless transmission based on IEE802.15.4 @ 2.4 GHz Automatic
More informationK580M GUIDA ALL INSTALLAZIONE INSTALLATION GUIDE INSTALLATIONSANLEITUNG NOTICE D INSTALLATION GUÍA PARA LA INSTALACIÓN
GUIDA ALL INSTALLAZIONE INSTALLATION GUIDE INSTALLATIONSANLEITUNG NOTICE D INSTALLATION GUÍA PARA LA INSTALACIÓN D-MNL0 17-01-2011 - Rev.05 Quadro di comando per motoriuttore T-ONE5 e T-ONE8 Control panel
More informationluxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor
ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor Product description Compact dimensions for luminaire installation For up to 10 DSI or LI devices (max. 5 per output channel)
More informationsw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS
INSTRUCTIONS MANUAL IM831-U v0.92 HRI-R40W sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS INDEX: GENERAL TYPES ACESSORIES AND OPTIONS
More informationLED pool light Intelligent Remote Controller OWNER S MANUAL PLP-REM-300
LED pool light Intelligent Remote Controller OWNER S MANUAL PLP-REM-300 lighting 402-0036-160914 Multi-functional Controller for Spectravision Pool Lights and 2 auxiliary circuits Table of contents Technical
More informationCopyright Graupner/SJ GmbH. Manual. mz-4 2 channel HoTT 2,4 GHz transmitter No. S1031
Copyright Graupner/SJ GmbH EN Manual mz-4 2 channel HoTT 2,4 GHz transmitter No. S1031 Index Introduction... 4 Service Centre... 4 Intended use... 5 Package content... 5 Technical Data... 5 Symbols Explication...
More informationPILOT Instructions 1. APPLICATIONS 2. OPERATING INDICATIONS 3. TERMINAL CONNECTIONS + - ON 3 OFF 10 OFF OFF 18/07/18
EN Instructions 8/07/8. APPLICATIS Control Unit specially designed for roller shutters whose tubular motors have integrated mechanical limit switches. Both radio receiver for emitter operations and Wirelessband
More informationWireless Receiver E28Q Mounting and Operating Instructions (Original operating instructions)
EN Wireless Receiver E28Q Wireless Receiver E28Q Mounting and Operating Instructions (Original operating instructions) Always read before initial operation! 28509900_E28Q_EN_2012-05-08.doc 1 / 12 1 Data
More informationOVEN INDUSTRIES, INC. Model 5C7-362
OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-362 THERMOELECTRIC MODULE TEMPERATURE CONTROLLER TABLE OF CONTENTS Features... 1 Description... 2 Block Diagram... 3 RS232 Communications Connections...
More informationRF ceiling microwave presence detector DALI / DSI
MWS3A-AT-DD Product Guide RF ceiling microwave presence detector DALI / DSI Overview The MWS3A-AT-DD is a passive microwave motion sensor combined with two output channels capable of controlling incandescent,
More informationInstallation & Operation Manual SAGA1-K Series Industrial Radio Remote Control
Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control Gain Electronic Co. Ltd. Table Of Contents Safety Considerations ------------------------------------------------------------2
More informationData sheet. Function description. Benefits
uminaire-integrated modules SESOTEC MB Sensor Modules 110042808 SESOTEC MB HF1 COM1 110051733 SESOTEC MB HF1 DAI 110059684 SESOTEC MB HF2 COM1 Function description With the new HF sensor modules, you,
More informationPWM LED strip dimmer module for the Velbus system
VMB1LED PWM LED strip dimmer module for the Velbus system CONTENTS CONTENTS... 2 DESCRIPTION... 3 CHARACTERISTICS... 3 VELBUS CHARACTERISTICS... 5 OVERVIEW... 6 LED INDICATION... 7 USE WITHOUT VELBUS...
More informationInstallation and Operating Instructions. Power IT Power Factor Controller RVC
Installation and Operating Instructions Power IT Power Factor Controller RVC Table of contents Page 1. Read this first... 3 About this Instruction Manual... 3 Safety... 3 Electromagnetic compatibility...
More informationCOD GB / 1.0 RBAND/UMS - RBAND/CSM
INTRODUCTION DESCRIPTION The RadioBand system is designed of Industrial, Commercial and Domestic door and gate applications where a safety edge is used. The system provides a wireless system replacing
More informationWIRELESS 868 MHz TEMPERATURE STATION Instruction Manual
WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this compact 868MHz Temperature Station which displays radio controlled time, date, indoor and outdoor
More informationTO.GO 2VA TO.GO 4VA TO.GO 2AS TO.GO 2A TO.GO 2AK TO.GO 4AK TO.GO 2QV TO.GO 4QV TO.GO 4ASE PROGRAMMING GUIDE
TO.GO 2A TO.GO 4A TO.GO 2VA TO.GO 4VA TO.GO 2AS TO.GO 4AS TO.GO 2AK TO.GO 4AK PROGRAMMING GUIDE TO.GO 4ASE TO.GO 2QV TO.GO 4QV INDEX TECHNICAL SPECIFICATIONS...2 ADVANCED ROLLING-CODE (ARC) 128 BIT...3
More informationCM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH
AC/DC LOW CURRENT CLAMP-ON METER CM605 ENGLISH User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments
More informationWireless wall transmitter, 1-gang with inscription space, Wireless wall transmitter, 3-gang with inscription space
Wireless wall transmitter, 1-gang with inscription space Order No. : 5331.. Wireless wall Order No. : 5333.. Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected
More information3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.
3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2 (Code 7 71 071 to 7 71 083) INSTRUCTION MANUAL ( M 981 200 / 00 A ) (c) CIRCUTOR S.A. ----- MKT- MKT2 - ELECTRONIC METERS -------- M-981 200 --- Page Nº 2 3
More informationET RXTX-RC Weatherproof Repeater Version 2011/010. Specifications. Encryption: Rolling Code. Frequency: MHz
ET RXTX-RC Weatherproof Repeater Version 2011/010 Specifications Encryption: Rolling Code Frequency: 433.92 MHz Transmitting range: Up to 900m (Line of sight, radio clutter free) Power input: 12 24V Ac/Dc
More informationMidland 248XL I NSTRUCTION GUI DE
Midland 248XL I NSTRUCTION GUI DE INDEX Introduction...2 Function and location of the controls...3 Installation...7 Power supply...7 Installing an antenna...7 How to use your Midland 248XL...8 Frequency
More informationPhoto-electric Amplifier ISG-A123 1-channel automatic amplifier
Photo-electric Amplifier -channel automatic amplifier Amplifier with modulated infrared light Range up to 25 m (82 ft) Automatic Level Control (ALC) according to assembly distance and direction Test function
More informationWireless Rain and Wireless Rain/Freeze Sensor
Wireless Rain and Wireless Rain/Freeze Sensor Installation and Operating Instructions for: WRC: Wireless Rain Sensor Combo WRT: Wireless Rain Sensor Transmitter WSR: Wireless Rain Sensor Receiver WRFC:
More informationIMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION
INSTALLATI INSTRUCTIS Model: RB-G-K10 IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIS BEFORE BEGINNING INSTALLATI The Miller Edge RBand Monitored Gate Edge Transmitter/Receiver system is intended to provide
More informationFluke 125. Getting Started. Industrial ScopeMeter
Fluke 125 Industrial ScopeMeter Getting Started GB Dec 2006, Rev. 1, 09/2009 2006, 2009 Fluke Corporation, All rights reserved. Printed in The Netherlands All product names are trademarks of their respective
More informationAURATON 2020 AURATON 2020 TX RX Plus
0 I 31 EN AURATON 2020, AURATON 2020 TX RX Plus AURATON 2020 AURATON 2020 AURATON 2020 TX RX Plus Preliminary notes The manual includes the information on AURATON 2020 and AURATON 2020 TX RX Plus controllers.
More informationFranck-Hertz Control Unit
R Franck-Hertz Control Unit 09105.99 PHYWE Systeme GmbH & Co. KG Robert-Bosch-Breite 10 D-37079 Göttingen Phone +49 (0) 551 604-0 Fax +49 (0) 551 604-107 E-mail info@phywe.de Internet www.phywe.de The
More informationFMT15101E, FMT15102E, FMT15104E, FMT15108E (Enclosed version) FMT15101, FMT15102, FMT15104, FMT15108 (No Case version)
FMT15101E, FMT15102E, FMT15104E, FMT15108E (Enclosed version) FMT15101, FMT15102, FMT15104, FMT15108 1, 2, 4, 8-Channel 151MHz Transmitter Features Long range up to 5km. 100mW Transmitter with current
More informationRadio Micro Force Manual v1.1
Radio Micro Force Manual v1.1 Preston Cinema Systems 1659 Eleventh Street Santa Monica CA 90404 tel 310-453-1852 fax 310-453-5672 www.prestoncinema.com Table of Contents 1. Description 2. Operation 3.
More informationDC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL
DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL Warnings and Safety symbols: Caution, refer to this manual before using the meter. Dangerous voltages. Meter is protected throughout by double insulation or
More informationLMM31. Dimmer Micromodule, 1 load USER MANUAL 20410/ LMM31 ALL RIGHTS RESERVED MARMITEK
LMM31 Dimmer Micromodule, 1 load USER MANUAL 20410/20111019 LMM31 ALL RIGHTS RESERVED MARMITEK TABLE OF CONTENTS TABLE OF CONTENTS... 2 SAFETY WARNINGS... 3 HOW DOES MARMITEK X-10 WORK?... 4 ADRESSES...
More informationTVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active
Technical manual BA 0318 Signal converter Isolation amplifier active for galvanic isolation, conversion and adjustment of electrical standard signals Evaluable input signals Direct voltage 0...10V / 0...1V
More informationUSER MANUAL 2AMDI511VPVRDS
USER MANUAL 2AMDI511VPVRDS SUBJECT INDEX: DESCRIPTION TECHNICAL SPECIFICATION DEVICE POWER SUPPLY AND CONNECTION TO THE LED MODULE OPERATION MODES LINEAR POTENTIOMETER MODE 100KOHM MODE 0-10V/1-10V PASSIVE
More informationWireless Data Gathering Panel (DGP) Model AL-1231
g GE Security Wireless Data Gathering Panel (DGP) Model AL-1231 Installation & Programming Guide Installation and Programming Guide Wireless DGP AL-1231 Part number: 466-2025-US Rev. H April 2005 Contents
More informationMRW 50, MRW 100, MRW 200. External Protection Barrier. Quick Installation Guide
MRW 50, MRW 100, MRW 200 External Protection Barrier Quick Installation Guide Version 1.1, October 2004 Copyright 2004 GE Interlogix B.V.. All rights reserved. GE Interlogix B.V. grants the right to reprint
More informationRev.8 03/08 SSRMAN-1P SERIES USERS MANUAL SSR INTELLIGENT PHASE ANGLE CONTROL MODULE COPYRIGHT 2008 NUWAVE TECHNOLOGIES, INC.
Rev.8 03/08 MAN-1P SERIES USERS MANUAL INTELLIGENT PHASE ANGLE MODULE COPYRIGHT 2008 MAN-1P Users Manual Page 2 TABLE OF CONTENTS 1. Ordering Codes... 2 2. Description... 2 2.1 Features... 3 3. Installation...
More informationfocushand 2 Users Manual FocusHAND System description
FocusHAND System description focushand 2 Users Manual FocusHAND is a wireless remote control unit with a DMX output, to be used for controlling lighting fixtures while focussing them. This means that the
More informationThe Discussion of this exercise covers the following points:
Exercise 5 Resistance and Ohm s Law EXERCISE OBJECTIVE When you have completed this exercise, you will be familiar with the notion of resistance, and know how to measure this parameter using an ohmmeter.
More informationUser Manual. Version 1.1
User Manual Version 1.1 Contents 1 Hardware... 4 1.1 Control Panel... 6 1.2 Power Supply and Battery Charging... 7 1.3 Photocells... 8 1.3.1 Mounting Photocells and Reflectors on Tripods... 9 1.3.2 Statuses
More informationKNX manual 1-channel flush-mounted switch actuator SU 1
KNX manual 1-channel flush-mounted switch actuator SU 1 4942520 2018-10-04 Contents 1 Function description 3 2 Operation 4 3 Technical data 5 4 The SU 1 application programme 7 4.1 Selection in the product
More informationZITARES ICD SELV constant current control gear, 2-channel, dimm- and programmable
ECG versions Order number ICD90-0QS-0/0-0/LI 00907 ) ) Output current Total power output x 0... 900 ma... 0 W Additional output currents can be selected by parallel connection of the outputs of the ECG,
More informationIRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL
IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL Confirm contents of package: 1 sensor, 1 cable, 1 wide lens (default), 1 narrow lens, mounting template, User s Guide. Install the sensor at the desired
More information