Model: &

Size: px
Start display at page:

Download "Model: &"

Transcription

1 600A True RMS Digital Clamp Meter Model: &

2 CONTENTS Page Number Details 3 Important Safety Information 4 Product overview 4 Key Functions 5 General Specification 5 Electrical Specification 5 AC (Ã) 6 AC (A) ( only) 6 AC Voltage (Ṽ) 6 DC Voltage (V) 6 Resistance (Ω) 6 Continuity Test 7 Diode Test 7 Capacitance 7 Temperature ( C) ( only) 8 Frequency (Hz) ( only) 8 NCV 8 Operation - AC Measurement 9 DC Current Measurement ( only) 9 AC Voltage Measurement 10 DC Voltage Measurement 10 Resistance Measurement 11 Continuity Test 11 Diode Measurement 12 Capacitance Measurement 13 Frequency 13 Temperature Measurement ( only) 13 Non-contact AC Voltage Sensing NCV 14 Power Gear (off) & Automatic Shutdown 14 Battery Replacement 14 Cleaning & Maintenance 2

3 IMPORTANT SAFETY INFORMATION When using electrical appliances basic safety precautions should always be followed. Check the clamp ammeter and test pen before use. If there is any damage or any abnormalities, do not use it. Do not use the clamp ammeter if the battery cover and rear cap is not in place, as there is a risk of electric shocking. Keep fingers within the scope of the test pen finger protection. Do not contact the bare wire and connector, the unused input terminal or the circuit being measured when the clamp ammeter is in operation. Ensure that function switches are set at the correct position prior to measurement. Do not perform gear conversion in measurement to guard against damage to the meter. Do not apply over 1000VDC or 750VAC between the clamp ammeter terminals and ground, to guard against damage to the meter. Be careful in measuring RMS voltage higher than 30V DC or AC, as there will be electric shocking. Do not measure voltage or current higher than the allowable input value. Set the function range switch at the maximum range position if the scope of the measured value cannot be defined. Before measurement of online resistance and diode or circuit on-off measurement, the power to the circuits being measured must be switched off and all capacitors should be completely discharged to assure measurement accuracy. When the LCD displays the low battery symbol, replace the battery immediately in order to ensure measurement accuracy. Remove the battery when the clamp meter is not in use for a long period of time. Do not change the internal wiring in the clamp ammeter, in order to guard against damage to the meter. Do not store or use the clamp ammeter in an explosive or flammable environment with high temperature, high humidity or a strong electromagnetic field. Clean the clamp meter case with a soft cloth and a neutral detergent. Do not use any chemicals, abrasives or solvents to avoid causing damage to the instrument. 3

4 PRODUCT OVERVIEW 1. Clamp head: a device used to measure AC/DC current and convert current into voltage. 2. Clamp body: designed for safe use and to protect the operator from touching dangerous areas. 3. Clamp head pulling handle: press the trigger to open the clamp head. 4. Dial switch: select the measurement function gear. 5. Function key: select basic functions. 6. LCD display area: displays the measured data and functional symbols. 7. Measure input terminal: measure the signal input High Voltage 9. Diode 2. Low Battery 10. Circuit on-off measurement 3. Relative value 11. Auto range 4. Auto shutdown 12. Max/min measurement 5. Data hold 13. Non-contact AC voltage sensing 6. Unit 14. Frequency conversion measurement 7. DC Signal 15. Temperature unit 8. AC Signal KEY FUNCTIONS SELECT HOLD MAX/ MIN REL Press in order to choose. Press and hold the key and the LCD will display VFC to enable frequency conversion signal measurement. It is only valid for AC voltage 600V and AC measurement. Press and hold to block frequency conversion signal measurement. Press this button once to enter data hold measurement mode and press again to exit the mode. Press and hold the button to turn the backlight on. If the button is not held down within 15 seconds the backlight will turn off automatically. Press once and the LCD will display MAX and enter maximum measurement mode. Press again and the LCD will display MIN indicating minimum measurement mode. Press and hold the button to exit maximum/minimum value measurement. It is only valid for AC voltage, AC current, resistance and temperature measurement. With the exception of DC current gear, under the non-read back stored record data mode, it is able to enter the relative measurement mode with by pressing REL. The main display will show: measured value - basic value. It is only valid for AC voltage, AC current, resistance and capacitance measurement. 4

5 REL (cont) FLIGHT Press again to exit relative value measurement mode. Under DC current gear measurement mode, press to enter clearing mode and the LCD will display. Press again to exit clearing mode. Press and hold this button to turn the torch function on. Press the button once and the torch function will turn off. GENERAL SPECIFICATION LCD Maximum display Polarity display Auto positive and negative polarity display. Overload display: OL or -OL. Low voltage display Figure 1 indicates that the battery voltage is lower than the working voltage. Sampling rate About 3/s. Sensor type Coil induction ( )/Hall effect sensor ( ). An additional reading error of ±1.0% may result when Text position error the power to be measured is not clamped at the centre of the clamp head. Impact resistance strength 1m fall impact. Max. openness of clamp head Electromagnetic field impact Power Dimensions Weight Operating temperature Storage temperature 30mm diameter, max. dimension of current conductor to be measured: 30mm diameter. The applicaton of device near electromagnetic field may result in unstable display or inaccurate readings. 3 AAA 1.5V zinc manganese batteries. 228mm x 77mm x 41mm. About 265g (inc. batteries). 0 C to 30 C (no higher than 80% RH). 30 C to 40 C (no higher than 75% RH). 40 C to 50 C (no higher than 45% RH). -20 C to 60 C (no higher than 80% RH). ELECTRICAL SPECIFICATION Accuracy: ± (% + word number), one year calibration time. Ambient temperature: 23 C ± 5 C. Ambient humidity: 80% RH. Temperature coefficient: 0.1 x (accuracy)/ C. AC (Ã) Display: current true value: applicable for 6.000A 0.001A ±(2.5% + 30) range from 10% to 60.00A 0.01A 600A 100%. ±(2.5% + 5) Frequency response: 600.0A 0.1A 50Hz~60Hz. 5

6 The measurement accuracy of non-sinusoidal wave various frequency current should be 5% higher than the former. AC (A) ( only) 60.00A 0.01A ± (2.5% + 5) 600A 600.0A 0.1A AC VOLTAGE (Ṽ) 6.000V 0.001V 60.00V 0.01V ± (1.2% + 5) 1000V DC 600.0V 0.1V 750V AC 750V 1V ± (1.5% + 5) DC VOLTAGE (V) 600.0mV 0.1mV ± (1.0% + 8) 6.000V 0.001V ± (0.8% + 1) 1000V DC 60.00V 0.01V ± (0.8% + 3) 750V AC 600.0V 0.1V 1000V 1V ± (1.0% + 3) DCI base number should be deleted by the ZERO key. Display: voltage true value; applicable for range from 10% to 100%. Voltage: input impedance 10MΩ. Frequency response: 40~400Hz. Input impedance 10MΩ. RESISTANCE (Ω) 600.0Ω 0.1Ω ± (1.2% + 2) 6.000kΩ 0.001kΩ 60.00kΩ 0.01kΩ ± (1.0% + 2) 1000V DC 600.0kΩ 0.1kΩ 750V AC 6.000MΩ 0.001MΩ ± (1.2% + 2) 60.00MΩ 0.01MΩ ± (1.5% + 5) CONTINUITY TEST Buzzer beeps when 600.0Ω 0.1Ω is about 1.2V <30Ω 1000V DC Open circuit voltage 750V AC 6

7 DIODE TEST ( ) 6.000V 0.001V CAPACITANCE Open circuit voltage is about 3.3V, measurable PN knot 3V positive pressure drop value. Silicon PN normal voltage value is about 0.5~0.8V nF 0.01nF ± (4.0% + 25) 999.9nF 9.999µF 99.99µF 999.9µF 0.1nF 0.001µF 0.01µF 0.1µF ± (4.0% + 5) 9.999mF 0.001mF ± (10%) 59.99mF 0.01mF For reference only V DC 750V AC 60.00nF 0.01nF ± (4.0% + 25) 600.0nF 6.000µF 60.00µF 600.0µF 0.1nF 0.001µF 0.01µF 0.1µF ± (4.0% + 5) 6.000mF 0.001mF ± (10%) 60.00mF 0.01mF For reference only TEMPERATURE ( C) ( ONLY) 1000V DC 750V AC -40 C~40 C 40 ~400 C 1 C ± (3.0% + 5) 400 C~1000 C ± (2.0% + 5) -40 F~ F~752 F 1 F ± (3.0% + 10) 752 F~1832 F ± (2.0% + 10) 1000V DC 750V AC 100V DC 750V AC

8 FREQUENCY Hz ( ONLY) 10Hz 0.01Hz ~ ~ 1 MHz 1kHz ± (0.1% + 4) 1000V DC 750V AC Requirement on input range: 100kHz: 100mVrms input range 20Vrms > 100kHz ~ 1MHz: 200mVrms input range 20Vrms. NCV Range NCV Accuracy 100Vrms; 10mm (LED/buzzer indication) OPERATION - AC MEASUREMENT Push the switch to AC current gear. Then press the trigger to open the clamp head to take the conductor to be measured, then slowly loosen the trigger until the clamp head is completely closed. Make sure that the conductor to be measured is clamped at the centre of the clamp head, otherwise it may result in an additional error. The clamp ammeter can only measure one current conductor. Measuring two or more current conductors concurrently may result in wrong measurement readings. Read the true value of AC directly from the display. Press and hold the SELECT key in AC gear to select VFC measurements and measure frequency converter current ( only). Current measurement must be operated within 0 ~40 C. If a positive reading is achieved after measuring DC current, the current direction will go from up to down. Do not loosen the trigger abruptly as the Hall component is sometimes sensitive to magnets, heat, mechanical stress and also to impact, which may cause short-time reading variation. Ensure the conductor to be measured is clamped at the centre of the clamp head. If it isn t, an additional reading error of ±1% may result. AC conversion adopts the AC coupling true RMS response mode, sinusoidal input correction. The accuracy of non-sinusoidal waves shall be adjusted as follows: - Crest factor 1.4~2.0, accuracy should be increased 1.0%. - Crest factor 2.0~2.5, accuracy should be increased 2.5%. - Crest factor 2.5~3.0, accuracy should be increased 4.0%. 8

9 DC CURRENT MEASUREMENT ( ONLY) Push the switch to DC current gear. If the LCD display is not set to zero, press REL to clear. After measuring the big current gear, the clamp head will be left with remanence and the LCD will have base values. Press the trigger to open the clamp head and take the conductor to be measured, then slowly loosen the trigger until the clamp head is completely closed. Ensure the conductor to be measured is clamped at the centre of the clamp head, otherwise an error may occur. The clamp ammeter can only measure one current conductor. Measuring two or more current conductors concurrently may result in incorrect measurement readings. Directly read out the measured DC current value from the display. Current measurement must be operated within 0 ~40 C. If a positive reading is achieved after measuring DC current, the current direction will go from up to down. Do not loosen the trigger abruptly as the Hall component is sometimes sensitive to magnetization, heat, mechanical stress and also to impact, which may cause short-time reading variation. Ensure the conductor to be measured is clamped at the centre of the clamp head. If it isn t, an additional reading error of ±1% may result. AC VOLTAGE MEASUREMENT Insert the red test pen into the V jack and the black test pen into the COM jack. Push the function range switch to the AC voltage measurement gear and connect the test pen in parallel with the power or load to be measured. Read the true value of the AC voltage from the display. Press and hold the SELECT key in AC voltage gear to select VFC measurement and measure the frequency converted voltage ( only). For , pressing and holding the SELECT key can select frequency measurements of AC voltage. the following conditions must be met when reading frequency value: input range range x 10%. (Testing range of frequency gear at voltage gear is 40Hz-400Hz). Do not input voltage higher than AC 750V. It may be feasible to measure higher voltage, but damage will be caused to the meter. 9

10 Pay attention to electric shocks when measuring high voltage. After completing all measurement operations, disconnect the test pen from the measured circuit. When the measured voltage is higher than the safety voltage of 30V AC, the meter LCD displays the high voltage warning prompt. When inputting overvoltage, higher than 750V AC gear range, the meter will automatically sound intermittent buzzing and the high voltage warning prompt will automatically flash. AC conversion adopts the AC coupling true RMS response mode, sinusoidal input for correction. The accuracy of non-sinusoidal wave shall be adjusted as follows: - Crest factor 1.4~2.0, accuracy should be increased 1.0%, - Crest factor 2.0~2.5, accuracy should be increased 2.5%, - Crest factor 2.5~3.0, accuracy should be increased 4.0%. DC VOLTAGE MEASUREMENT Insert the red test pen into the V jack and the black test pen into the COM jack. Push the function range switch to the DC voltage measurement and connect the test pen in parallel with the power or load to be measured. Directly read the measured resistance value from the display. Do not input voltage higher than 1000V. It may be feasible to measure higher voltage, but damage will be caused to the meter. In order to obtain a precise reading when measuring at 600mV gear, the relative measurement function can be adopted. Firstly, input the test pen under the short-circuit condition, press the REL button and read the resistance measurement value. Afterwards, the meter automatically deducts the test pen displayed value under short-circuit condition. Watch out for electric shocks when measuring high voltage. After completing all measurement operations, disconnect the test pen from the measured circuit. When the measured voltage is higher than the safety voltage of 30V DC, the meter LCD will display the warning prompt. When inputting overvoltage higher than 1000V DC gear range, the meter will automatically sound intermittent buzzing and the high voltage warning prompt will automatically flash. RESISTANCE MEASUREMENT Insert the red test pen into the Ω jack and the black test pen into the COM jack. Push the function range switch to the measurement gear Ω, press SELECT to 10

11 select resistance measurement Ω and connect the test pen in parallel with the two terminals of measured resistance. Directly read the measured resistance value from the display. If the open circuit of resistance being measured exceeds the maximum range of the meter, the display will show OL. Before measuring resistance on-line, the power of circuits being measured shall be powered off and all capacitors will release residues of electric charges to assure measurement accuracy. CONTINUITY TEST Insert the red test pen into the Ω jack and the black test pen into the COM jack. Push the function range switch to the measurement gear, press SELECT to select circuit on-off measurement and connect the test pen in parallel with the two terminals of measured circuit. When the measured resistance between the two terminals <30Ω, the circuit should be deemed conductive and the buzzer will sound continuously. When resistance is 30Ω and 60Ω, the buzzer will not sound. When resistance is >60Ω, the buzzer will not sound. Directly read the measured resistance value loaded by the circuit from the display. When checking on-line circuit on-off conditions, it is required, prior to measurement, to switch off all power in the measured circuit and discharge all residual charges in the capacitor. With respect to the circuit on-off measurement, open-circuit voltage is approximately -3.5V and range should be 600Ω measurement gear. Do not input voltage higher than 30V DC or AC, as it may cause personal injury. After completing all measurement operations, disconnect the test pen from the measured circuit. DIODE MEASUREMENT Insert the red test pen into the Ω jack and the black test pen into the COM jack. The polarity of the red and black test pen is respectively + and -. Push the function range switch to the measurement gear, select diode measurement and directly read out the approximate forward direction PN junction voltage. 11

12 For silicon PN junction generally 500~800mV is confirmed to be the normal value. OL will be displayed when the measured diode is open-circuit or the polarity is inversely connected. Before measuring diode, the power circuits being measured shall be powered off and all capacitors shall release residues of electric charged to assure the measurement accuracy, The test open-circuit voltage of diode is approximately 3.5V. Do not input voltage higher than 30V DC or AC, as it may cause personal injury. After completing all measurement operations, disconnect the test pen from the measured circuit. CAPACITANCE MEASUREMENT Insert the red test pen into the V jack and the black test pen into the COM jack. Measure by REL mode. Push the range switch to the measurement gear, press SELECT to select capacitance and connect the test pen in parallel with the two terminals of measured capacitance. Directly read out the capacitance value of the measured circuit from the display. It is recommended to carry out the capacitance measurement with test short line input, thus reducing the impact caused by distributed capacitance. If the measured capacitance is short circuited or capacitance exceeds the maximum range of the meter, the display will show OL. Under capacitance measurement mode, the simulation bar indicator is forbidden. It will take a longer time to achieve the correct reading when measuring capacitance larger than 600µF. To ensure the measurement accuracy, it is recommended to discharge all residual charges in the capacitor before the test. Then, input the meter for measurement, which is particularly important to the capacitor with high voltage. It is required to prevent damage to the meter and personal injury. After completing the measurement operation, disconnect the test pen from the measured capacitance. 12

13 FREQUENCY Insert the red test pen into the Hz jack and the black test pen into the COM jack. Push the range switch to the measurement gear Hz and connect the test pen in parallel with the signal source to be measured. Directly read out the measured frequency value from the display. It is required to meet the input range a when measuring: 100kHz 100mVrms a 20Vrms. Do not input frequency higher than 30Vrms, as it may cause personal injury. After completing all measurement operations, disconnect the test pen from the measured circuit. TEMPERATURE MEASUREMENT ( only) Push the range switch to C F gear and the LCD will display OL, the shortcircuit test pen displays the room temperature. Insert the temperature K type socket into the corresponding hole. Place the temperature probe to detect the measured surface and several seconds later, directly read out the measured Celsius temperature value from the LCD. Press SELECT to select Fahrenheit temperature measurement. The meter should not be operated in a place with ambient temperature beyond the range 18 C to 28 C as results can be affected, particularly evident in a low temperature environment. Do not input voltage higher than 30V DC or AC, as it may cause personal injury. After completing all measurement operations, remove the temperature probe. NON-CONTACT AC VOLTAGE SENSING NCV In order to sense whether there is AC voltage or electromagnetic field in this space, place the front end of the clamp meter near to the conductor to be tested in order to sense detection (distance <10mm). When the electric field voltage is 100VAC, the LCD will display -, which has four levels, -, - -, and subject to sensing voltage. The buzzer will continue to beep and the LED will flash a red light. 13

14 POWER GEAR (OFF) & AUTOMATIC SHUTDOWN The instrument should be powered off. If you re not turning the knob switch or pressing the key to the clamp ammeter within the user-defined shutdown time (default 15 mins), the display will be blank and enter the low power consumption dormant state. Press any key to wake up the meter. Press the SELECT key to start up the machine and the automatic shutdown function is forbidden. BATTERY REPLACEMENT Shut down the clamp meter and move away the test pen located at the input terminal. Place the meter with the panel facing down and unscrew the battery box screws, take off the battery cap and remove the old batteries. Place the new batteries into the compartment, observing the polarities. After installing the new batteries, replace the battery cap and screw on the screws. CLEANING & MAINTENANCE The clamp meter should be maintained and serviced by qualified personnel. Clean the outer case with a clean, dry cloth. Do not use any chemicals, abrasives or solvents that could cause damage to the meter. INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL & ELECTRONIC EQUIPMENT. This symbol indicate that separate collection of Waste Electrical and Electronic Equipment (WEEE) or waste batteries is required. Do not dispose of these items with general household waste. Separate for the treatment, recovery and recycling of the materials used. Waste batteries can be returned to any waste battery recycling point which are provided by most battery retailers. Contact your local authority for details of the battery and WEEE recycling schemes available in your area. Made in China V.1.0

Mini Clamp Meter Model:

Mini Clamp Meter Model: Mini Clamp Meter Model: 72-2985 1 CONTENTS Page Number Details 2 What s Included 3 Important Safety Information 3 Technical Specification 4 Product Overview 5 LCD Overview 6 Operation - AC/DC Voltage Measurement

More information

Digital Clamp Meter Model: &

Digital Clamp Meter Model: & Digital Clamp Meter Model: 72-7224 & 72-7226 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,

More information

Digital Multimeter, Pen Type

Digital Multimeter, Pen Type MODEL: D03127 Digital Multimeter, Pen Type 1 CONTENTS Page Number Description 3 Important Safety Information 3 Electrical Symbols 4 Overview 4 Measurement Operation 5 AC & DC Voltage Measurement 5 AC &

More information

True RMS Digital Multimeter Model:

True RMS Digital Multimeter Model: True RMS Digital Multimeter Model: 72-7780 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,

More information

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

USER MANUAL 600A AC Clamp Meter + NCV Model MA610 USER MANUAL 600A AC Clamp Meter + NCV Model MA610 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech MA610 Clamp Meter. This meter measures

More information

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM USER MANUAL Model MA440 400A AC Clamp Meter DMM Model MA443 True RMS 400 AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM Introduction Thank you for selecting the Extech EX44x Series

More information

UT207A/208A/209A Operating Manual. Table of Contents

UT207A/208A/209A Operating Manual. Table of Contents Table of Contents Title Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Display Symbols Functional Buttons The Effectiveness

More information

MODEL: D03128 CLAMP METER

MODEL: D03128 CLAMP METER MODEL: D03128 CLAMP METER 1 CONTENTS Page Number Details 3 Important Safety Information 3 Features 4 Product Overview 5 Switches, Buttons & Input Jacks 5 LCD 6 Specifications 6 Electrical Specifications

More information

DIGITAL MULTIMETER AUTORANGING

DIGITAL MULTIMETER AUTORANGING MODEL: D03124 DIGITAL MULTIMETER AUTORANGING 1 CONTENTS Page Number Details 2 Introduction 2 What s Included 3 Important Safety Information 3 Symbol Guide 4 Overview 5 Buttons 5 Display Indicators 6 General

More information

Multifunction Digital

Multifunction Digital MS2009A Multifunction Digital Clamp Meter User Manual 200/600 OFF 2/20 NCV SEL MAX V RAN HOLD OFF MS2009A AC CLAMP METER AUTO MAX C F kmω μmva CONTENTS Safety requirements...1 Safety signs...1 Notes...1

More information

MS2109A AC/DC Clamp Meter. User Manual. Contents

MS2109A AC/DC Clamp Meter. User Manual. Contents MS2109A AC/DC Clamp Meter User Manual Contents 1. Safety information 1 1.1 Preparation 1 1.2 Usage 1 1.3 Signs and Labels 2 1.4 Maintenance 2 2. Description 2 2.1 Part name 3 2.2 Switch and button description

More information

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual DUAL DISPLAY DIGITAL MULTIMETER User s Manual MS8250D 1. Safety Information Warning Use caution and follow all safety guidelines to prevent electric shock or damage to the meter. Please ready carefully

More information

NOTE: Fully read and understand this manual before using this Digital Multimeter.

NOTE: Fully read and understand this manual before using this Digital Multimeter. ASTROAI USER MANUAL AUTO RANGING DIGITAL CLAMP METER Thank you for purchasing the Auto Ranging Digital Clamp Meter from AstroAI. The AstroAI Auto Ranging Digital Clamp Meter is designed to be safely and

More information

AC/DC CLAMP METER USER S MANUAL

AC/DC CLAMP METER USER S MANUAL AC/DC CLAMP METER USER S MANUAL CONTENTS PAGE SAFETY INFORMATION SYMBOL EXPLANATION SAFETY PRECAUTIONS 1 1 2 MAINTENANCE 3 GENERAL DESCRIPTION 4 PANEL DESCRIPTION 4 OPERATING INSTRUCTIONS... 7 SPECIFICATIONS

More information

User Manual. All rights reserved. Specifications are subject to change without notice.

User Manual. All rights reserved. Specifications are subject to change without notice. User Manual All rights reserved. Specifications are subject to change without notice. LIMITED WARRANTY AND LIMITATION OF LIABILITY Customers enjoy one-year warranty from the date of purchase. This warranty

More information

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 800 Amp AC/DC True RMS Clamp Meter Model EX730 Introduction Congratulations

More information

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual Item ref: 600.104UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE User Manual Please read this manual thoroughly and ensure all contents are fully understood before using the apparatus. WARNING

More information

400Amp True RMS AC/DC Clamp Meter Model EX613

400Amp True RMS AC/DC Clamp Meter Model EX613 User's Guide 400Amp True RMS AC/DC Clamp Meter Model EX613 Introduction Congratulations on your purchase of this Extech EX613 True RMS Clamp Meter. This meter measures AC Current, DC Current, AC/DC Voltage,

More information

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at ASTROAI USER MANUAL DT132A 4000 Count Auto-Ranging Multimeter Thank you for purchasing the AstroAI DT132A 4000 Count Auto-Ranging Multimeter. It is a 3 ¾ digit, 3999 counts, auto-ranging digital multimeter.

More information

OPERATOR S INSTRUCTION MANUAL

OPERATOR S INSTRUCTION MANUAL 2 OPERATOR S INSTRUCTION MANUAL CLAMP METER HOLD 20 A 200 A 2 A 600 600 LIGHT ON/OFF Digital Clamp Meter 2 20 200 A khz COM CAT.II MAX 600 CONTENTS 1. General instruction.....1 2. Description...1 2.1 Precautions

More information

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature USER GUIDE True RMS Digital Multimeters EX350 Series EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature Table of Contents 1. INTRODUCTION 3 2. SAFETY INFORMATION 4 3.

More information

Digital Multimeter with Backlight

Digital Multimeter with Backlight MODEL: D03126 Digital Multimeter with Backlight 1 CONTENTS Page Number Description 3 Important Safety Information 3 What s Included? 4 Overview 4 Front Panel Description 5 General Specification 5 DC Voltage

More information

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual Item ref: 600.100UK MTM01 DIGITAL MULTITESTER User Manual Please read this manual thoroughly and ensure all contents are fully understood before using the apparatus. Warning To avoid possible electric

More information

DVM1190 DIGITAL MULTIMETER

DVM1190 DIGITAL MULTIMETER DIGITAL MULTIMETER 1. Introduction Thank you for buying the. This digital multimeter has a large LCD, a data-hold function and a backlight. The device uses a very practical safety mechanism that keeps

More information

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A TABLE OF CONTENTS TITLE PAGE Safety Information Safety Symbols... 1 Meter Description...

More information

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter DL6508 User's Guide 1500Amp True RMS AC/DC Clamp Meter Introduction Congratulations on your purchase of this DL6508 True RMS Clamp Meter. This meter measures AC Current, DC Current, AC/DC Voltage, Resistance,

More information

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV. MS8250A/B DIGITAL MULTIMETER OPERATION MANUAL AUTO DC AC REL hfe PCLINK % C F kmωkz nµmfav MS8250A DIGITAL MULTIMETER Auto Power Off RANGE REL HOLD FUNC NCV A ma OFF 10A A ma 10A FUSED 600V CAT IV COM

More information

ProfiScale MULTI Multimeter

ProfiScale MULTI Multimeter 1,5 V 9V 200 mv 600 V 200 ma 1/10 A ProfiScale MULTI Multimeter en Operating instructions BURG-WÄCHTER KG Altenhofer Weg 15 58300 Wetter Germany Introduction Want the reassurance of knowing whether current

More information

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology ENGLISH INSTRUCTION MANUAL 2000A Digital Clamp Meter True RMS Measurement Technology NON-CONTACT VOLTAGE TESTING INRUSH CURRENT LOW IMPEDANCE DATA HOLD RANGE HOLD AUDIBLE CONTINUITY DIODE TEST CAPACITANCE

More information

UT207/208. Digital Clamp Multimeter P/N:

UT207/208. Digital Clamp Multimeter P/N: UT207/208 Digital Clamp Multimeter P/N: 41451522 Model UT207/208 OPERATING MANUAL Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical

More information

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

AC/DC DIGITAL CLAMP METER OPERATION MANUAL AC/DC DIGITAL CLAMP METER OPERATION MANUAL HYS005661 A0 ACCESSORIES 6. ACCESSORIES 1) Test Leads: Electric Ratings 1000V 10A 1 pair (set) 2) Operating Manual 1 copy 3) 1.5V AAA Battery 3 piece - - 55 -

More information

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES TABLE OF CONTENTS / EN TITLE TABLE OF CONTENTS PAGE 1. SAFETY INFORMATION... 1 2. TECHNICAL SPECIFICATIONS... 2 3. PARTS & CONTROLS...

More information

User Manual. All rights reserved. Specifications are subject to change without notice.

User Manual. All rights reserved. Specifications are subject to change without notice. User Manual All rights reserved. Specifications are subject to change without notice. LIMITED WARRANTY AND LIMITATION OF LIABILITY Customers enjoy one-year warranty from the date of purchase. This warranty

More information

DCM730. Digital Clamp Meter User s Manual

DCM730. Digital Clamp Meter User s Manual DCM730 Digital Clamp Meter User s Manual Table of Contents LIMITED WARRANTY AND LIMITATION OF LIABILITY...1 Out of the Box...1 Safety Information...2 INTRODUCTION...4 Components and Buttons...6 Names of

More information

AMM-1022 Digital Multimeter USER`S MANUAL

AMM-1022 Digital Multimeter USER`S MANUAL Digital Multimeter USER`S MANUAL www.tmatlantic.com CONTENTS 1. SAFETY INFORMATION.3 2. DESCRIPTION..6 3. SPECIFICATIONS.8 4. OPERATING INSTRUCTION..11 4.1 Voltage measurement...11 4.2 Current measurement

More information

Pocket Size Digital Multimeter with USB Model: A & A

Pocket Size Digital Multimeter with USB Model: A & A Pocket Size Digital Multimeter with USB Model: 72-7730A & 72-7732A 1 IMPORTANT SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This instrument is

More information

KMD-S04 Multímetro de bolsillo

KMD-S04 Multímetro de bolsillo www.grupotemper.com KMD-S04 Multímetro de bolsillo Table of Contents Title Page Overview ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 3 Unpacking Inspection ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 4 Safety Information

More information

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com USER'S MANUAL ACDC-100 TRMS ACDC-100 Versatile AC/DC Clamp-on Multimeter Series 1 1) SAFETY This manual contains information

More information

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL 1 1. SAFETY INFORMATION SAFETY SYMBOLS Warning! Dangerous Voltage (Risk of electric shock). Caution! Refer to the user s manual before using this

More information

CONTENTS MS2033A. 1.Introduction Safety Information...01

CONTENTS MS2033A. 1.Introduction Safety Information...01 MS2033A AC Digital Clamp Meter User s Manual CAT III 600 V CONTENTS 1.Introduction...01 2.Safety Information...01 2.1 Precautions...02 2.2 Safety Symbols...03 3. Description...04 3.1 Front Panel...04 3.2

More information

Digital automotive analyser 13 function with ic

Digital automotive analyser 13 function with ic Digital automotive analyser 13 function with ic Model no: TA201 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and

More information

LCR METER Model:

LCR METER Model: LCR METER Model: 72-10465 1 CONTENTS Page Number Details 3 Important Safety Information 3 Measurement Range & Accuracy 3 Ambient Conditions 4 Features 4 Impedance Explanation 4 Measurement Mode 5 LCD Description

More information

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com Model ST-9933 True RMS Autoranging Digital Multimeter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-8 Technical...4-5 Accuracy...5-8 Display Description...

More information

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free User s Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 400A AC/DC Clamp Meter Model MA220 Introduction Thank you for selecting

More information

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual DUAL DISPLAY DIGITAL MULTIMETER User s Manual MS8250D Introduction MS8250D is a stable, safe, reliable compact digital handheld 6600 count, True RMS, auto-ranging multimeter. This meter can measure AC/DC

More information

Digital Automotive Analyser 14 Function With IC

Digital Automotive Analyser 14 Function With IC Digital Automotive Analyser 14 Function With IC Model no: TA202 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and

More information

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D T8211D 1 1. SAFETY INFORMATION BE EXTREMELY CAREFUL IN THE USE OF THIS METER. Improper use of this device can result in electric shock or destroy of

More information

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

User's Guide Extech EX Amp Clamp Meter with IR Thermometer User's Guide Extech EX810 1000 Amp Clamp Meter with IR Thermometer Patented Introduction Congratulations on your purchase of the Extech EX810 Clamp Meter. This meter measures AC/DC Voltage, AC Current,

More information

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL Table of Contents TITLE PAGE 1. GENERAL INSTRUCTIONS 1 1.1 Precaution safety measures 1 1.1.1 Preliminary 1 1.1.2 During use 2 1.1.3 Symbols

More information

LCR METER Model:

LCR METER Model: LCR METER Model: 72-3520 1 CONTENTS Page Number Details 2 What s Included 3 Important Safety Information 3 Ambient Conditions 3 Features 3 Impedance Explanation 4 Measurement Mode 4 LCD Description 5 Product

More information

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE INSTRUCTION MANUAL Auto-Ranging Digital Multimeter MM400 DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE 600V 10A 40MΩ 2 GENERAL SPECIFICATIONS Klein Tools MM400 is an auto-ranging

More information

400Amp True RMS AC Clamp Meter + NCV

400Amp True RMS AC Clamp Meter + NCV User Guide 400Amp True RMS AC Clamp Meter + NCV Model MA410T Introduction Thank you for selecting the Extech MA410 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,

More information

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER with Temperature Probe Copyright 2007 Elenco Electronics, Inc. Contents 1. Safety Information 3,4 2. Safety Symbols 5 3. Front Plate

More information

Pocket Size Digital Multimeter Models: and

Pocket Size Digital Multimeter Models: and Pocket Size Digital Multimeter Models: 72-8150 and 72-8155 1 IMPORTANT SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. Please operate according to

More information

USER'S MANUAL DMR-6700

USER'S MANUAL DMR-6700 USER'S MANUAL Multimeter True RMS DMR-6700 CIRCUIT-TEST ELECTRONICS www.circuittest.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL Warnings and Safety symbols: Caution, refer to this manual before using the meter. Dangerous voltages. Meter is protected throughout by double insulation or

More information

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual AM-510 Commercial / Residential Multimeter AM-510-EUR Digital Multimeter Users Manual AM-510 Commercial / Residential Multimeter AM-510-EUR Digital Multimeter English Users Manual Limited Warranty and

More information

Model UT10A: OPERATING MANUAL Table of Contents (1)

Model UT10A: OPERATING MANUAL Table of Contents (1) Table of Contents (1) Table of Contents Title Page Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Functional Buttons Measurement

More information

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español Owner's Manual AC/DC Clamp Meter Model No. 82369 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español

More information

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter User s Manual MiniTec TM Series Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter Introduction Congratulations on your purchase of Extech s MN26 Autoranging Multimeter. This

More information

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC) User Manual Compact Autoranging Clamp Meters with NIST-Traceable Calibration Models 20250-55 (400 A AC), 20250-56 (400 A AC/DC) THE STANDARD IN PRECISION MEASUREMENT 1065DGMAN_20250-55,-56 DS Clamp Meter

More information

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10 CONTENTS 1. SAFETY INFORMATION.1 2. DESCRIPTION..4 3. SPECIFICATIONS.6 4. OPERATING INSTRUCTION..9 4.1 Voltage measurement...10 4.2 Current measurement 10 4.3 Resistance measurement...12 4.4 Diode test.12

More information

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use http://www.all-sun.com EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL V Read this owners manual thoroughly before use WARRANTY This instrument is warranted to be free from defects in material and workmanship

More information

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use True RMS Digital Multimeter DVM98 1 Safety information This multimeter has been designed according to IEC - 1010 concerning electronic measuring instruments with an overvoltage category (CAT II) and pollution

More information

Not for Reproduction

Not for Reproduction 1 ADVANCE PRODUCT SERVICE INFORMATION SUBJECT: OPERATING PROCEDURES FOR EXTECH DIGITAL MULTIMETER No: #66 DATE: 05/31/2010 MODELS: 19602 DIGITAL MULTIMETER A digital multimeter is necessary for electrical

More information

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330 USER MANUAL Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330 Introduction Congratulations on your purchase of the Extech EX330 Meter. The EX330 offers AC/DC Voltage, AC/DC Current, Resistance,

More information

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH AC/DC LOW CURRENT CLAMP-ON METER CM605 ENGLISH User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Digital Clamp Meter DSA540A IMPORTANT: RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. If you find damage, notify the carrier at once. Shipping damage

More information

200Amp AC Clamp Meter + NCV Model MA250

200Amp AC Clamp Meter + NCV Model MA250 User's Guide 200Amp AC Clamp Meter + NCV Model MA250 Introduction Congratulations on your purchase of this Extech MA250 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance,

More information

1.General instructions Specifications Description...7

1.General instructions Specifications Description...7 USER S Manual CONTENTS 1.General instructions...1 1.1 Precautions safety measures...1 1.1.1 Preliminary...1 1.1.2 During use...2 1.1.3 Symbols...4 1.1.4 Instructions...5 1.2 Protection mechanisms...6 2.

More information

User Manual Digital Clamp Multimeter. model no.: MSR-C600

User Manual Digital Clamp Multimeter. model no.: MSR-C600 User Manual Digital Clamp Multimeter model no.: MSR-C600 Overview This Operating Manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings

More information

DIGITAL MULTIMETER INSTRUCTION MANUAL

DIGITAL MULTIMETER INSTRUCTION MANUAL DIGITAL MULTIMETER INSTRUCTION MANUAL 1 CONTENTS CONTENTS 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 1 1.2 DURING USE 2 1.3 SYMBOLS 3 1.4 MAINTENANCE 4 2. DESCRIPTION 5 2.1 NAMES OF COMPONENTS 5 2.2 SWITCH,

More information

AC750 DIGITAL CLAMP METER

AC750 DIGITAL CLAMP METER AC750 DIGITAL CLAMP METER OWNER S MANUAL (English) Français, Español, Deutsch: www.cpsproducts.com CONTENTS 1. Safety Information 1.1 Preliminary...1 1.2 Usage...2 1.3 Symbols...3 1.4 General Use...4 2.

More information

MS2030 CAT III 600 V A V AUTO RS232

MS2030 CAT III 600 V A V AUTO RS232 MS2030 AC Digital Clamp Meter User s Manual CAT III 600 V AUTO RS232 A V CONTENTS 1.Introduction...1 2.Safety Information...1 2.1 Precautions...1 2.2 Safety Symbols...3 3. Description...4 3.1 Front Panel...4

More information

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at USER MANUAL Model MA150 200A AC Mini Clamp-on Meter Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech MA150 AC Mini Clamp Meter. This device

More information

MS8223A. CAT.IIi 600 V

MS8223A. CAT.IIi 600 V Pen-type Digital Multimeter Manual MS8223A CAT.IIi 600 V CONTENTS 1. Safety Information......1 1.1 Preparing for use...1 1.2 During Use......2 1.3 Safety Symbols...3 1.4 Maintenance...4 2. Description......4

More information

Pen-type DIGITAL MULTITESTER

Pen-type DIGITAL MULTITESTER BST-MT267 Pen-type DIGITAL MULTITESTER INSTRUCTION MANUAL Index 1. Introduction... 2. Safety Notes... 3. Features... 4. Specifications... 5. General... 6. Instrument Layout... 7. Measurement... 8. Maintenance...

More information

R/C SMD Tweezers Multimeter Model RC200

R/C SMD Tweezers Multimeter Model RC200 User's Guide R/C SMD Tweezers Multimeter Model RC200 Introduction Congratulations on your purchase of the Extech RC200 RC Tweezers Multimeter This meter, using the tweezers adaptor, measures SMD capacitors,

More information

Model UT201/202: OPERATING MANUAL. Table of Contents

Model UT201/202: OPERATING MANUAL. Table of Contents Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons The Effectiveness

More information

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL Ω CONTENTS CONTENTS 1. SAFETY INFORM...1 4.4 Range Transform...10 1.1 Preliminary...1 4.5 Auto Power Off...10 1.2 During use...2 4.6 Preparation For Measurement...11

More information

S-11 S-11. Digital Multimeter Operating Instruction. Digital Multimeter Operating Instruction

S-11 S-11. Digital Multimeter Operating Instruction. Digital Multimeter Operating Instruction S-11 Digital Multimeter Operating Instruction S-11 Digital Multimeter Operating Instruction I. General introduction Welcome to use this product! This product is one kind of 3 6/7 portable multipurpose

More information

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2. Contents 1. General instructions. 1.1 Precautions safety measures... 1.2 Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.2 LCD Display 2.3 Keypad. 3. Function description. 3.1

More information

Table of Content. The Statement Safety Statement Safety Instructions Safety Operation Specifications Safety Symbols...

Table of Content. The Statement Safety Statement Safety Instructions Safety Operation Specifications Safety Symbols... Table of Content The Statement... 1 Safety Statement... 1 Safety Instructions... 2 Safety Operation Specifications... 2 Safety Symbols... 4 Overview... 6 LCD Display... 6 Buttons... 8 Rotary Switch...

More information

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL Contents I. General...- 1 - Ⅱ. Open-package Inspection...- 2 - III. Safety Considerations... - 3 - IV.Instrument Panel & Button Function Description...- 9 -

More information

312, 316, 318. Clamp Meter. Users Manual

312, 316, 318. Clamp Meter. Users Manual 312, 316, 318 Clamp Meter Users Manual PN 1989445 July 2002 Rev.2, 2/06 2002, 2006 Fluke Corporation. All rights reserved. Printed in China. All product names are trademarks of their respective companies.

More information

The Meter Structure The Figure 2-1 shows the Meter structure.

The Meter Structure The Figure 2-1 shows the Meter structure. P/N:110401104496X The Meter Structure The Figure 2-1 shows the Meter structure. 1. USB Terminals 2. LCD Display 3. Functional Buttons 4. Rotary Switch 5. Power adaptor Input Terminals 6. 10A Input Terminal

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Digital Clamp Meter DSA660 IMPORTANT: RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. If you find damage, notify the carrier at once. Shipping damage

More information

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC USER MANUAL True RMS Digital Multimeters EX360 Series EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC EX365 True RMS DMM with 10A AC/DC Current Additional User Manual

More information

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n. MS8265 DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD ON/OFF LIGHT 1000V CAT II 600V CAT III MS8265 200K 2M 20M 20K 200M KHz 2K 20 200 2 20 200μ 200 20μ 750 2μ 1000 200n F 20n 10A 2m 200m 10 10

More information

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology INSTRUCTION MANUAL Auto-Ranging Digital Multimeter er True RMS Measurement Technology MM700 DATA & RANGE HOLD LOW IMPEDANCE AUDIBLE CONTINUITY MIN / MAX / RELATIVE TEMPERATURE DIODE TEST CAPACITANCE &

More information

770E DIGITAL MULTIMETER OPERATOR S MANUAL

770E DIGITAL MULTIMETER OPERATOR S MANUAL 770E DIGITAL MULTIMETER OPERATOR S MANUAL TABLE OF CONTENTS 1.Overview... 1 2.Panel Layout...1/2 3. Safety information... 2 4. Specical cautions for operation.... 2 5.General specifications...2/3 6.Testing

More information

Model : OPERATING MANUAL Table of Contents (1)

Model : OPERATING MANUAL Table of Contents (1) Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Functional Buttons Measurement Operation A. DC

More information

Sales: Technical: Fax:

Sales: Technical: Fax: DATA SHEET Order code Manufacturer code Description 85-0733 n/a n/a The enclosed information is believed to be correct, Information may change without notice due to product improvement. Users should ensure

More information

User s Guide. 400A AC/DC Clamp Meter. Model MA220

User s Guide. 400A AC/DC Clamp Meter. Model MA220 User s Guide 400A AC/DC Clamp Meter Model MA220 Introduction Thank you for selecting the Extech MA200 AC/DC Clamp Meter. This meter measures AC/DC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,

More information

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd. MT-3110 3 5/6 Smart Digital Clamp Meter User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd. 1.Safety Information Warnings Special attention shall be paid when using the meter, improper

More information

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO AMPROBE 1 Congratulations! You are now the owner of an AMPROBE Instrument. It has been quality crafted according to quality standards and contains quality components

More information

User Manual Digital Multimeter. model no.: MSR-U1000

User Manual Digital Multimeter. model no.: MSR-U1000 User Manual Digital Multimeter model no.: MSR-U1000 This Operating Manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings and Notes

More information

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623 User's Guide 400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623 Introduction Congratulations on your purchase of this Extech EX623 True RMS Clamp Meter. This meter measures AC Current, DC

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330 User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330 Introduction Congratulations on your purchase of the Extech EX330 Meter. The EX330 offers AC/DC Voltage, AC/DC Current,

More information