ME6000 Sensor guide for MegaWin
|
|
- Dominic Copeland
- 6 years ago
- Views:
Transcription
1 ME6000 Sensor guide for MegaWin
2 ME6000 Sensor guide for This manual is applicable to: 1) ME channel system revision MT-M6T4-0 2) ME channel system revision MT-M6T8-0 3) ME channel system revision MT-M6T16-0 4) ME4ISO Isolation Unit* revision MP-ISO4-1 *for detailed compatibility see separate ME4ISO Isolation Unit Device Manual with MegaWin software versions 3.0 and onwards N O T E! Mega Electronics Ltd reserves all rights to improve, change and modify the products and the contents of manuals without prior notice. Mega Electronics Ltd Mega Electronics Ltd. Microkatu 1 P.O. Box 1199 FIN KUOPIO FINLAND tel (0) fax (0) mega@megaemg.com web: Mega Electronics Ltd 2009
3 Order code IMPORTANT! Before operating the device, please read this manual thoroughly and retain it for future reference.! CAUTION Caution. These statements identify conditions or practices that could result in damage to the equipment or other property.! WARNING Warning. These statements identify conditions or practices that could result in personal injury or loss of life. N O T E! Note. These statements identify condition or practices that could result in performance loss of the equipment or must be otherwise paid attention to. Mega Electronics Ltd 2009
4 ME6000 Sensor guide for Table of contents 1 GETTING STARTED HOW TO SEE THE AVAILABLE ME6000 SENSORS IN MEGAWIN 8 2 SIGNAL DEFINITION 9 3 CREATING NEW CONFIGURATION 11 4 CREATING NEW PROTOCOL 13 5 SIGNAL CALIBRATION PREPARING ME6000 FOR CALIBRATION CALIBRATION MEASUREMENT CALIBRATION CALCULATION OF GAIN AND OFFSET SENDING CALIBRATION VALUES TO ME GONIOMETER & TORSIOMETER SENSORS GENERAL DESCRIPTION Single axis goniometer Twin axis goniometers Single axis torsiometer CONNECTING THE SENSOR SIGNAL ADJUSTMENT CLEANING GENERAL INSTRUCTIONS 26 7 FOOT SWITCH SENSOR GENERAL DESCRIPTION CONNECTING THE SENSOR SIGNAL ADJUSTMENT CLEANING GENERAL INSTRUCTIONS 28 8 INCLINOMETER SENSOR GENERAL DESCRIPTION 29 Mega Electronics Ltd 2009
5 Order code CONNECTING THE SENSOR SIGNAL ADJUSTMENT CLEANING GENERAL INSTRUCTIONS 30 9 ACCELEROMETER SENSOR GENERAL DESCRIPTION CONNECTING THE SENSOR SIGNAL ADJUSTMENT CLEANING GENERAL INSTRUCTIONS POLAR HEART RATE SENSOR SET GENERAL DESCRIPTION CONNECTING THE SENSOR SIGNAL ADJUSTMENT CLEANING GENERAL INSTRUCTIONS ECG SENSOR GENERAL DESCRIPTION CONNECTING THE SENSOR SIGNAL ADJUSTMENT CLEANING GENERAL INSTRUCTIONS LOAD CELL GENERAL DESCRIPTION CONNECTING THE SENSOR SIGNAL ADJUSTMENT CLEANING GENERAL INSTRUCTIONS GYRO SENSOR GENERAL DESCRIPTION CONNECTING THE SENSOR SIGNAL ADJUSTMENT CLEANING GENERAL INSTRUCTIONS GSR SENSOR GENERAL DESCRIPTION CONNECTING THE SENSOR 41 Mega Electronics Ltd 2009
6 ME6000 Sensor guide for 14.3 SIGNAL ADJUSTMENT CLEANING GENERAL INSTRUCTIONS TIDAL VOLUME SENSOR GENERAL DESCRIPTION CONNECTING THE SENSOR CLEANING GENERAL INSTRUCTIONS FORCE / PRESSURE SENSOR GENERAL DESCRIPTION CONNECTING THE SENSOR SIGNAL ADJUSTMENT CLEANING GENERAL INSTRUCTIONS MAINTENANCE AND SERVICE CALIBRATION CLEANING GETTING ASSISTANCE COMMENTS FOR USE 49 Mega Electronics Ltd 2009
7 Order code GETTING STARTED This guide describes the procedure how you bring new sensor into use with the ME6000 device in MegaWin measuring system. The most commonly used ME6000 sensors are also described in this document. As the first step connect the sensor cable to the connector ch1 ch2 (4 and 8 channel device) or to connector ch1 ch4 (16 channel device). This guide describes the procedure assuming that the sensor (in focus) is connected into the channel 1. Sensor Ch1 Other sensors ME6000 Figure 1-1. Connecting the sensor cable to the ME6000 Biomonitor 8 ch Before you proceed, make sure that MegaWin is operating properly with ME6000 device. If needed, refer MegaWin user s manual and ME6000 device manual. If the sensor is corresponding to some of predefined ME6000 sensors (signals) in MegaWin, you may enter to chapter 3 (Creating New Configuration). Predefined sensors (signals) are EMG, Goniometer, Accelerometer, Inclinometer, Polar interface, ECG, Torque and Gyrometer. 7 Mega Electronics Ltd 2009
8 ME6000 Sensor guide for 1.1 How to see the available ME6000 sensors in Megawin 1. Start MegaWin. 2. Select menu command Options System Setup. 3. In System Setup window select some of ME6000 configurations in Configurations area (see figure). Available ME6000 sensors Select some ME6000 configuration Figure 1-2. Available ME6000 sensors If the sensor provides new signal type (sensor is not defined in MegaWin) follow the instructions in next chapter. Mega Electronics Ltd
9 Order code SIGNAL DEFINITION In this guide we use Force sensor/signal as new example signal. 1. Select menu command Options System Setup 2. In System Setup window select some of ME6000 configurations in Configurations area (see figure). 3. In System Setup window select menu command Signal New 4. Signal window will be displayed. Figure 2-1. Signal window for definition 5. Input the name of your signal to NAME field. In our example the name is Force. 6. In ICON field is shown the default sensor/signal symbol. 7. You can change signal symbol as follows: - Double click ICON field - press Load from file button (in Picture explorer ) - Browse to MegaWin signal image folder (as default it is located in C:\Program Files\MEGAWIN\Images\Signals ) - Select the desired signal file and press Open press OK in Picture explorer window 8. DO NOT CHANGE the SIGTYPE, which is given by MegaWin. 9. Input the unit of the signal. In our example the unit is N (=Newton). 10. FACTOR (=Gain) values should be RAWOFFS (=offset) value should be You do not need to change AVROFFS ME6000 does not use this value. 13. ME6000 SENSOR must be Sensor. 14. Select ME6000 SENSOR number 1. 9 Mega Electronics Ltd 2009
10 ME6000 Sensor guide for N O T E! If you have several same type (for ex. Force) of sensors, you must define each sensor/signal (in the same way as explained here) and give own number for it (example Force1 : Sensor 1, Force 2 : Sensor 2, etc 15. Example Signal definition (Force signal). Figure 2-2. Example signal definition (Force) 16. Finally press OK. Now the new signal (example: Force) is available in the signal list to be used in Configurations. New ME6000 sensor/signal Figure 2-3. New sensor/signal in signal list Mega Electronics Ltd
11 Order code CREATING NEW CONFIGURATION The measurement configuration is the answer to the question with which device and with which signals the measurement will be performed? N O T E! Configuration contains the hardware definitions for the measurement. 1. Select menu command Options System Setup 2. In System Setup window select some of ME6000 configurations in Configurations area (see figure). 3. In System Setup window select menu command Configuration New 4. Give the name for the configuration. Figure 3-1. Configuration name and description definition 5. Description is not mandatory. 6. Press OK. 7. Configuration content area is empty. Figure 3-2. Configuration content area for new configuration 11 Mega Electronics Ltd 2009
12 ME6000 Sensor guide for 8. Drag the ME6000 device icon from device list to the Configuration content area. Drag by pressing mouse left button on top of the icon keep button pressed and move the icon. In the configuration content area - release mouse button. Figure 3-3. Device icon dragged to the Configuration content area 9. Drag the signal icon (example: Force) from signal list to the Configuration content area. Drag and drop as instructed in previous step to the channel 1 location. Figure 3-4. Signal icon dragged to the Configuration content area Now the new configuration is ready to be selected for use in new protocol. This configuration appears also to the list of available configurations (at the bottom of the System Setup window). N O T E! If you have same type of sensor such as Force1, Force2 etc you may use those just once in a configuration. For example Force1 to channel1, Force2 to channel2 etc (NOT Force1 to channel1, Force1 to channel2) Mega Electronics Ltd
13 Order code CREATING NEW PROTOCOL The measurement configuration is the answer to the question How measurement will be performed and in which form the data will be created? N O T E! Protocol controls the measurement and defines the form (raw, averaged) of recorded data. 1. Press Protocol button in MegaWin Main window. 2. Press New button in Protocol window. It starts the Protocol Editor wizard, which guides you through the process of configuring the protocol. Figure 4-1. Starting new protocol definition 3. Give protocol name (example : Force measurement), select Advanced protocol and press Next button. Figure 4-2. Protocol name and editor mode selection 4. Select the configuration (example: Force configuration) and press Next button. 13 Mega Electronics Ltd 2009
14 ME6000 Sensor guide for Figure 4-3. Selection of the configuration 5. Select body region (Example: General body) and press Next button. Figure 4-4. Selection of body region 6. Select source(s) for the signal: Figure 4-5. Selection of signal source Mega Electronics Ltd
15 Order code Press Select source button. Select No name to be the signal name. Press OK button. Then press Next button. 7. Select measurement type On-line (real time measurement) and the protocol component Raw free. Figure 4-6. Selection of measurement type and protocol component 8. Press Pick to protocol button. 9. Component properties of raw free are opened. Make the selections as shown in the figure below. You only need to set total duration to be 3 min. Other setting may be as default. Figure 4-7. Settings of the raw free component 10. Press OK button. 15 Mega Electronics Ltd 2009
16 ME6000 Sensor guide for 11. Finally press Finish button. Figure 4-8. Completed protocol definition Now the new protocol is ready to be used in measurements. The protocol is available in the protocol list in the Protocol window. Figure 4-9. New protocol shown in Protocol window Mega Electronics Ltd
17 Order code SIGNAL CALIBRATION New sensor/signal must be calibrated with ME6000 before it can be used in real measurements in MegaWin. The goal of the calibration is to measure and calculate the correct gain and offset values for the signal and finally send them to ME6000 to be used during the measurement. 5.1 Preparing ME6000 for calibration Start MegaWin and ME6000. Make sure that ME6000 communicates with MegaWin. 1. Select menu command Options System Setup 2. Select the ME6000 configuration which has made for new sensor/signal (Example: Force configuration) and which will be used in calibration. 3. Press mouse right button on the ME6000 device icon in Selected configuration contents area. 4. Select menu command Send calibration values. Figure 5-1. Mouse right click at ME6000 icon. 5. The Calibration values window will be opened. 6. If the current gain and offset in the ME6000 differs from the values you are going to send, continue in the next phase 7. Figure 5-2. Calibration values window for sending calibration values to ME Mega Electronics Ltd 2009
18 ME6000 Sensor guide for Otherwise you may close the window and move to next chapter Calibration measurement. 7. Select the new values from configuration you want to send. Figure 5-3. Selection of the values to be sent to ME Then press button: 9. New calibration values are transferred to ME6000. New calibration values set message indicates that ME6000 is ready to use these calibrated signals. Figure 5-4. Message after sending values to ME Press OK button. Figure 5-5. Calibration values window after sending values to ME Close the Calibration values window. 12. Make sure that the sensor cable is connected to ME6000 and it has attached properly for the calibration measurement. Mega Electronics Ltd
19 Order code N O T E! The ME6000 calibration protocol MUST be a RAW measurement. On-line measurement is recommended. Previously, in chapter 4 we have defined raw protocol, which can be used in the calibration measurement. 5.2 Calibration measurement The purpose in the calibration measurement is to get two known signal levels (lower and higher) to the measured data. 1. Define the patient information for calibration measurement. Press Person button in MegaWin Main window. Make the New person definition (see further information in MegaWin User s manual). Close Person window. 2. Press Measure button in MegaWin Main window. 3. Select protocol and person. (in example: Force measurement and Calibration data). Figure 5-6. Measure window 4. Press Run protocol button. 5. Start the measurement by pressing: 6. Measure the lower known signal level (MINIMUM) and press marker (marker1). In our example we have NO weight on the sensor. 7. Measure the higher known signal level (MAXIMUM) and press marker (marker2). In our example we have placed 20 kg weight on the sensor. 8. Repeat steps 6 7 for all signals need to be calibrated. 9. Stop and save the measurement. N O T E! Event markers help you to locate the correct minimum and maximum levels for calibration. 19 Mega Electronics Ltd 2009
20 ME6000 Sensor guide for Figure 5-7. The data of the calibration measurement 5.3 Calibration calculation of gain and offset The purpose of calibration is to produce new Factor (Gain) and Raw offset (offset) values into channel s Device-signal-channel window in the System setup. 1. Open the calibration measurement data to View window (see figure 5-7). 2. Select Cursor and move it using Previous marker or Next Marker buttons to the known MINIMUM level (marker 1) on the channel to be calibrated. If there is not a marker at that site then press the space key to lock the cursor. 3. Click the Freeze Cursor button, in the Freeze channels pop-up select the channels you wish to calibrate and click OK. 4. The Statistics window appears. Unlock the differential cursor using the space key and move it to the known MAXIMUM level (marker 2) of the channel. If there is not a marker at that site, then press the space key again to lock the cursor. 5. Double-click the box of the Y-dif value for the channel to be calibrated to open the Calibration window. Double click this box Figure 5-8. Activation of the calibration window Mega Electronics Ltd
21 Order code Figure 5-9. Calibration window 6. The Y-min and Y-Max fields are displaying the minimum and maximum levels. Type the actual signal values in Actual Y-Min and Actual Y-Max field. Check Set zero. Actual Y-Min is 0 N (no weight on the sensor) and Actual Y-Max is 196,2N (20 kg on the sensor). Figure Calibration window after new values given N O T E! Set zero must be must be checked! 7. Click Calibrate to make the calibration. The new values are set in the channel s Device-signal-channel window in the System setup. Figure MegaWin calibration message window 8. Press OK button. 21 Mega Electronics Ltd 2009
22 ME6000 Sensor guide for 9. Close Calibration window. 10. By using Cursor you can check, if the Actual Y-Min and Actual Y-Max datapoints has got new, correct values. 11. Close Cursor. 12. Repeat steps 2 11 until all needed signals are calibrated. 13. Check the new values in the channel s Device-signal-channel window in the System setup. If the Factor and Raw offset values has been changed it indicates that calibration has been successful (original values: Factor=1 and offset = 0). Figure Settings of Force signal after calibration (Example) 5.4 Sending calibration values to ME6000 The purpose of this action is to transfer valid calibration values to the ME6000. After this phase the ME6000 device is ready to measure the calibrated signal. 1. Open the System Setup window. 2. Select the configuration, which has been used in calibration. Example: Force configuration 3. Press mouse right button on the ME6000 device icon in Selected configuration contents area. 4. Select menu command Send calibration values. 5. Select the new values from configuration you want to send (Example: select Sensor1). Then press Arrow button and new calibration values are transferred to ME6000. New calibration values set message indicates that ME6000 is ready to use these calibrated signals. Figure The window for sending calibration values to ME6000 Mega Electronics Ltd
23 Order code GONIOMETER & TORSIOMETER SENSORS 6.1 General description The comprehensive range of goniometer and torsiometer sensors are intended for quick, simple, and accurate measurement of joint movement in multiple planes. The sensor is connected to the Measurement Unit through Preamplifier. Goniometer Sensor Preamplifier (MEGO) Connector Terminals Preamplifier Adapter for models SG and Q Figure 6-1. Goniometer / Torsiometer with Preamplifier Single axis goniometer Single axis goniometer permits the measurement of angles in one plane along the axis X-X. This goniometer is intended mainly for the measurement of finger and toe flexion/extention. Telescopic Endblock Fixed Endblock X Z Y Y Z X Linear movement along Z-Z Figure 6-2. Single axis goniometer 23 Mega Electronics Ltd 2009
24 ME6000 Sensor guide for Twin axis goniometers Twin axis goniometer permits the measurement of angles in two planes along axis X- X and axis Y-Y. The outputs of the two channels are independent of linear movements along axis Z-Z. Telescopic Endblock Fixed Endblock X Z Y Y Z X Linear movement along Z-Z Figure 6-3. Twin axis goniometer Single axis torsiometer Single axis torsiometer permits the measurement of rotations in one plane, e.g. forearm pronation/supination. Telescopic Endblock Fixed Endblock Figure 6-4. Single axis torsiometer 6.2 Connecting the sensor In general, there are four types of joint sizes: finger and toe; wrist; elbow and knee; and back. There are no fixed rules governing which size of sensor is most suitable for a particular joint; this depends on the size of the subject. The sensor must be capable of reaching across the joint so that the two endblocks can be mounted where least movement occurs between the skin and underlying skeletal structure. In certain circumstances more than one size of sensor will be appropriate. Mega Electronics Ltd
25 Order code Figure 6-5. Examples for placing the sensor Connect the sensor as following: 1. Place the sensor over the joint you intend to measure. 2. Secure the endblocks to the surface (for most cases it is recommended to use standard medical double sided adhesive tape). 3. Connect the sensor terminals to the Preamplifier. The red dot mark on the terminals should face the arrow mark on preamplifier (figure 6-6). Figure 6-6. Connecting the sensor to the Preamplifier In goniometers and torsiometers type SG and Q, an adapter (type A100) is needed (figure 6-7): Figure 6-7. Connecting sensor type SG and Q to the Preamplifier to MEGO-1 goniometer preamplifier. SG anf Q type sensors can be connected to MEGO-3 preamplifier without adapters. N O T E! Use GTF Adapter when connecting to the Preamplifier Cable to ME channels Measurement Unis. 4. Connect the Preamplifier to the Measurement Unit. 5. Turn on the Measurement Unit. 6. Adjust the signal in MegaWin. 25 Mega Electronics Ltd 2009
26 ME6000 Sensor guide for 6.3 Signal Adjustment 6.4 Cleaning In order to guarantee the accuracy of the sensor it is recommended to perform two point check prior to the angular measurement. This can be achieved by zeroing the sensor against known straight edge (e.g. a ruler) and displacing it by a known angle (usually 90 ). Following, you should calibrate the signal in MegaWin PC Software by setting the minimum and maximum levels. On how to calibrate the signal in MegaWin, please refer to MegaWin User s Manual. If the results of the two point check are not within the required accuracy then the Sensor needs to be further calibrated in relation to its Preamplifier. On how to perform this procedure please refer to the Technical Manual or contact you local dealer. The equipment can be calibrated, for example, by the hospital maintenance staff according to the instructions given in the Technical Manual. You can clean the sensor by wiping it with cloth damp with soapy water. To disinfect the sensor use disinfectant instead of soap.! CAUTION Do not use solvents, acidic or strong alkaline materials. Also, do not sink the Sensor or the Preamplifier in fluid. When cleaning or disinfecting, the sensor must be disconnected from the Measurement Unit. 6.5 General instructions Handle the sensor carefully. Be careful not to drop the sensor on hard surfaces. Do not wash the sensor with water and avoid extremely high humid conditions. Recommended maximum use of 30 minutes in humid place (relative humidity over 80%) without proper protection (e.g. water proof kit). Before cleaning the sensor shall be disconnected from the device Do not expose to temperatures under 0 C /32 F /273K or above 50 C / 122 F / 323K without proper isolation. Do not open any of the sensor parts. When disconnecting the sensor from the Measurement Unit, pull at the connector. Do not pull at the cable and do not rotate the connector. When not in use place the sensor in its box. During usage the minimum permissible values of bend radius must be observed all times. Mega Electronics Ltd
27 Order code FOOT SWITCH SENSOR 7.1 General description The Foot Switch Set is designed to detect gait events in ambulatory subjects. The Foot Switch pads are to be placed underneath the feet, while maintaining a reliable connection to the Measurement Unit safely, away from any weight-bearing part of the limb. Adapter Cable (MEFS) MIE Foot Switch Figure 7-1. Foot Switch sensor 7.2 Connecting the sensor The Foot Switch Set is compounded of four pads - two for each foot. The short pads are to be placed underneath the heels (as shown in green in figure 7-1); and the long pads are to be placed underneath the toes (as shown in red in figure 7-1). The Set operates on two channels (one for each foot), and has four impact positions for each foot: heel, heel and toe, toe and no impact. Connect the Foot Switch Set as following: 1. Place the pads underneath the feet of the patient. 2. Secure the pads to the surface (for most cases it is recommended to use standard medical double sided adhesive tape). 3. Connect the pads to the Measurement Unit. N O T E! Use GTF Adapter when connecting to the Preamplifier Cable to ME channel Measurement Units. 4. Turn on the Measurement Unit. 5. Adjust the signal in MegaWin. 27 Mega Electronics Ltd 2009
28 ME6000 Sensor guide for 7.3 Signal adjustment The signal appears in MegaWin in the following curve: 4 1 No Impact Heel 3 2 toes Heel and toes Figure 7-2. Foot Switch curve You can flip the curve in MegaWin by setting the minimum level to 4 (no impact) and the maximum level to 2 (heel and toes). On how to adjust the signal in MegaWin PC Software, please refer to MegaWin User s Manual. 7.4 Cleaning You can clean the sensor by wiping it with cloth damp with soapy water. To disinfect the sensor use disinfectant instead of soap.! CAUTION Do not use solvents, acidic or strong alkaline materials. Also, do not sink the Sensor or the Preamplifier in fluid. When cleaning or disinfecting, the sensor must be disconnected from the Measurement Unit. 7.5 General instructions Handle the Set parts carefully. Be careful not to drop on hard surfaces. Do not wash with water and avoid extremely high humid conditions. Recommended maximum use of 30 minutes in humid place (relative humidity over 80%) without proper protection ( e.g. water proof kit). Do not expose to temperatures under 0 C /32 F /273K or above 50 C / 122 F / 323K without proper isolation. Do not open any of the Set s parts. When disconnecting the adapter from the Measurement Unit, pull at the connector. Do not pull at the cable and do not rotate the connector. When not in use place the Set in its box. Mega Electronics Ltd
29 Order code INCLINOMETER SENSOR 8.1 General description Inclinometer sensor is intended to indicate the inclination angle in measurement where there is no fixed reference point. The sensor can be used for measuring within range of +/-60. Connector Fixation Tape (on the back) Inclinometer Sensor Figure 8-1. Inclinometer sensor 8.2 Connecting the sensor The Inclinometer has two channels which enable measuring the parameters on both X-axis and Y-axis. Connect the Inclinometer sensor as following: 1. Place the Inclinometer on the surface you intend to measure. 2. Secure the Inclinometer to the surface using the fixation tape on the back of the sensor. You can also use strap or belt for that purpose. 3. Connect the Inclinometer to the Measurement Unit. N O T E! Use GTF Adapter when connecting to the Preamplifier Cable to ME channel Measurement Units. 4. Turn on the Measurement Unit and wait 24 seconds for the automatic calibration process to complete, before you start the measurement. 5. Adjust the signal in MegaWin. 29 Mega Electronics Ltd 2009
30 ME6000 Sensor guide for 8.3 Signal Adjustment The Inclinometer calibration is done automatically when it is connected to the Measurement Unit and the power is on. The sensor sends three reference signals for the values -60, 0 and +60. The process is repeated twice in an overall period of 24 seconds, after which the sensor is ready for use in the measurement. Following the automatic calibration you can adjust the signal in MegaWin PC Software to correspond to its application in the measurement. On how to adjust the signal in MegaWin, please refer to MegaWin User s Manual. 8.4 Cleaning You can clean the sensor by wiping it with damp cloth. You can also use alcohol to clean the surface of the sensor.! CAUTION Do not use solvents, acidic or strong alkaline materials. Also, do not sink the Sensor or the Preamplifier in fluid. When cleaning or disinfecting, the sensor must be disconnected from the Measurement Unit. 8.5 General instructions The Inclinometer includes sensitive electronics and microprocessor technology. Follow theses general instructions when handling the sensor: Handle the Inclinometer carefully. Be careful not to drop on hard surfaces. Do not wash with water and avoid extremely high humid conditions. Recommended maximum use of 30 minutes in humid place (relative humidity over 80%) without proper protection ( e.g. water proof kit). Do not expose to temperatures under 0 C /32 F /273K or above 50 C / 122 F / 323K without proper isolation. Do not open any of the sensor parts. When disconnecting the sensor from the Measurement Unit, pull at the connector. Do not pull at the cable and do not rotate the connector. When not in use place the sensor in its box. Mega Electronics Ltd
31 Order code ACCELEROMETER SENSOR 9.1 General description The Accelerometer sensor is designed for measuring acceleration changes in free movement. Accelerometer Sensor Connector Fixation Tape (on the back) Figure 9-1. Accelerometer Sensor 9.2 Connecting the sensor The Accelerometer has two models: 2-axis model (type VP00366) for measuring movement acceleration on horizontal plane (X-X and Y-Y) and 3-axis model (type VP00355) for measuring movement acceleration on vertical and horizontal plane (X- X, Y-Y and Z-Z). Connect the Accelerometer as following: 1. Place the Accelerometer on the surface you intend to measure. 2. Secure the sensor to the surface using the fixation tape on the back. You can also assist strap or belt for that purpose. 3. Connect the sensor to the Measurement Unit. N O T E! Use GTF Adapter when connecting to the Preamplifier Cable to ME channel Measurement Units. 4. Turn on the Measurement Unit. 5. Adjust the signal in MegaWin. 31 Mega Electronics Ltd 2009
32 ME6000 Sensor guide for 9.3 Signal adjustment The following procedure is referring to figure 9-2. For the 2- axis Model (type VP00366) you should make the adjustment as shown in diagrams 1 and 2. For the 3- axis model ((type VP00355) make also the adjustment as shown in diagram Place the Accelerometer in an upwards position. 2. Displace the sensor by Set the signal in MegaWin for the first position to 0g and for the second position to 1g (on how to adjust the signal in MegaWin, please refer to MegaWin User s Manual). 0g 0g 90 1g 90 1g Cleaning Figure 9-2. Accelerometer signal adjustment You can clean the sensor by wiping it with damp cloth. You can also use alcohol to clean the surface of the sensor.! CAUTION Do not use solvents, acidic or strong alkaline materials. Also, do not sink the Sensor or the Preamplifier in fluid. When cleaning or disinfecting, the sensor must be disconnected from the Measurement Unit. 9.5 General instructions The Accelerometer includes sensitive electronics and microprocessor technology. Follow theses general instructions when handling the sensor: Handle the Accelerometer carefully. Be careful not to drop on hard surfaces. Do not wash with water and avoid extremely high humid conditions. Recommended maximum use of 30 minutes in humid place (relative humidity over 80%) without proper protection ( e.g. water proof kit). Do not expose to temperatures under 0 C /32 F /273K or above 50 C / 122 F / 323K without proper isolation. Do not open any of the sensor parts. When disconnecting the sensor from the Measurement Unit, pull at the connector. Do not pull at the cable and do not rotate the connector. When not in use place the sensor in its box. Mega Electronics Ltd
33 Order code POLAR HEART RATE SENSOR SET 10.1 General description The Heart Rate Sensor Set is designed for measuring heart rate. The Set includes three main parts: Heart Rate Sensor, type MEHR. Polar Hear Rate Transmitter. Polar Strap. Calibration led Signal led Connector TM Polar Strap TM Polar Heart Rate Transmitter Figure Heart Rate Sensor Set Heart Rate Sensor 10.2 Connecting the sensor Connect the Heart Rate Sensor Set as following: 1. Attach the Polar Strap and Transmitter across the patient s chest. 2. Secure the Heart Rate Sensor underneath the Strap. Note: do not place the Sensor further than 70cm away from the Transmitter. 3. Connect the Sensor to the Measurement Unit. N O T E! Use GTF Adapter when connecting to the Preamplifier Cable to ME channel Measurement Units. 4. Turn on the Measurement Unit. 5. The calibration red led indicating the automatic calibration process is in progress. Wait approximately 10 seconds for the process to complete. 6. The signal green led starts to blink, indicating the heart rate signal. 7. Adjust the signal in MegaWin. 33 Mega Electronics Ltd 2009
34 ME6000 Sensor guide for 10.3 Signal adjustment The Polar sensor calibration is done automatically when it is connected to the Measurement Unit and the power is on. The sensor sends two reference signals for the values 40 BPM and 150 BPM. The process is repeated twice in an overall period of 10 seconds, after which the sensor is ready for use in the measurement. The adjustment of the signal is done in MegaWin program. Please refer to MegaWin User Manual for further instructions Cleaning You can clean the Set parts by wiping them with damp cloth. You can also use alcohol to clean the surface areas. You can clean the Polar Hear Rate Transmitter and Strap with water and soap. Pat dry with e.g. paper towel, and leave in open air to dry.! CAUTION Do not use solvents, acidic or strong alkaline materials. Also, do not sink the Set parts in fluid. When cleaning or disinfecting, the sensor must be disconnected from the Measurement Unit General instructions The Heart Rate Sensor Set includes sensitive electronics and microprocessor technology. Follow theses general instructions when handling the Set: Handle the Heart Rate Sensor Set carefully. Be careful not to drop on hard surfaces. Do not wash the Heart Rate Sensor with water and avoid extremely high humid conditions. Recommended maximum use of 30 minutes in humid place (relative humidity over 80%) without proper protection ( e.g. water proof kit). Do not expose to temperatures under 0 C /32 F /273K or above 50 C / 122 F / 323K without proper isolation. Do not open any of the Set parts. When disconnecting from the Measurement Unit, pull at the connector. Do not pull at the cable and do not rotate the connector. When not in use place the Set in its box. Mega Electronics Ltd
35 Order code ECG SENSOR 11.1 General description ECG Sensor (type MEECG) is designed for measuring the heart ECG signals. The Sensor operates on one channel and is to be used with standard surface electrodes. ECG Sensor (MEECG) Surface Electrodes Figure ECG Sensor Connecting the sensor Connect the ECG Sensor Set as following: 1. Place the surface electrodes on the chest as shown in figure Connect the Sensor to the Measurement Unit. 3. Connect the ECG Sensor to the electrodes. N O T E! Use GTF Adapter when connecting to the Preamplifier Cable to ME channel Measurement Unit. 4. Turn on the Measurement Unit. 5. Adjust the signal in MegaWin. 35 Mega Electronics Ltd 2009
36 ME6000 Sensor guide for 11.3 Signal adjustment 11.4 Cleaning The adjustment of the signal is done in MegaWin program. Please refer to MegaWin User s Manual for further instructions. You can clean the sensor using a non-fluffing cloth dampened in cleaning fluid, such as water and mild hand soap solution.! CAUTION Be careful not to rub too forcefully. Do not use alcohol based fluids or corrosive chemicals! Do not sink sensor in the cleaning fluid! 11.5 General instructions The sensor includes sensitive electronics and microprocessor technology. Follow theses general instructions when handling the sensor: Handle the sensor carefully. Be careful not to drop the sensor on the hard surface. Do not wash the sensor with water and avoid extremely high humid conditions. Recommended maximum use of 30 minutes in humid place (relative humidity over 80%) without proper protection ( e.g. water proof kit). Do not expose to temperatures under 0 C /32 F /273K or above 50 C / 122 F / 323K without proper isolation. Do not open any of the sensor parts. When disconnecting the sensor from the Measurement Unit, pull at the connector. Do not pull at the cable and do not rotate the connector. Mega Electronics Ltd
37 Order code LOAD CELL 12.1 General description 12.2 Connecting the sensor Load cell sensor is used for force measurements (N). Sensor operates with one channel Connect the Load cell as following: 1. Fix sensor to platforms from fixing nuts. 2. Connect the Sensor to the Measurement Unit. N O T E! Use GTF Adapter when connecting to the load cell sensor to ME channel Measurement Unit. 3. Turn on the Measurement Unit. 4. Adjust the signal in MegaWin Signal adjustment 12.4 Cleaning The adjustment of the signal is done in MegaWin program. Please refer to MegaWin User s Manual for further instructions. With Load cell calibration user must give two known values for load cell. These can be for example 0 N (no load on load cell) and 500 N (known load on load cell = 50,97 kg load on sensor) You can clean the sensor using a non-fluffing cloth dampened in cleaning fluid, such as water and mild hand soap solution.! CAUTION Be careful not to rub too forcefully. Do not use alcohol based fluids or corrosive chemicals! Do not sink sensor in the cleaning fluid! 37 Mega Electronics Ltd 2009
38 ME6000 Sensor guide for 12.5 General instructions The sensor includes sensitive electronics and microprocessor technology. Follow theses general instructions when handling the sensor: Handle the sensor carefully. Be careful not to drop the sensor on the hard surface. Do not wash the sensor with water and avoid extremely high humid conditions. Recommended maximum use of 30 minutes in humid place (relative humidity over 80%) without proper protection. Do not expose to temperatures under 0 C /32 F /273K or above 50 C / 122 F / 323K without proper isolation. Do not open any of the sensor parts. When disconnecting the sensor from the Measurement Unit, pull at the connector. Do not pull at the cable and do not rotate the connector. Mega Electronics Ltd
39 Order code GYRO SENSOR 13.1 General description 13.2 Connecting the sensor Gyro sensor is used for rotation speed measurements (deg/sec). Sensor operates with one channel Connect the gyro sensor as following: 1. Connect the Sensor to the Measurement Unit. 2. Fix sensor to person / object you want to measure. N O T E! Use GTF Adapter when connecting to the load cell sensor to ME channel Measurement Unit Signal adjustment 3. Turn on the Measurement Unit. 4. Adjust the signal in MegaWin. The adjustment of the signal is done in MegaWin program. Open system setup from MegaWin PC software and make new configuration where you select gyro sensor for some channel. Make measurement for recording offset level. Start raw data measurement and keep gyro sensor still. Stop measurement and check raw offset level. Open system setup from MegaWin and select configuration where gyro sensor is used and press right button of mouse on top of gyro sensor on configuration and select properties. Calculate Factor value from following Factor = Raw offset * 0,09715 Change value for Factor and press OK. 39 Mega Electronics Ltd 2009
40 ME6000 Sensor guide for 13.4 Cleaning You can clean the sensor using a non-fluffing cloth dampened in cleaning fluid, such as water and mild hand soap solution.! CAUTION Be careful not to rub too forcefully. Do not use alcohol based fluids or corrosive chemicals! Do not sink sensor in the cleaning fluid! 13.5 General instructions The sensor includes sensitive electronics and microprocessor technology. Follow theses general instructions when handling the sensor: Handle the sensor carefully. Be careful not to drop the sensor on the hard surface. Do not wash the sensor with water and avoid extremely high humid conditions. Recommended maximum use of 30 minutes in humid place (relative humidity over 80%) without proper protection ( e.g. water proof kit). Do not expose to temperatures under 0 C /32 F /273K or above 50 C / 122 F / 323K without proper isolation. Do not open any of the sensor parts. When disconnecting the sensor from the Measurement Unit, pull at the connector. Do not pull at the cable and do not rotate the connector. Mega Electronics Ltd
41 Order code GSR SENSOR 14.1 General description 14.2 Connecting the sensor GSR sensor is used for galvanic skin response measurements. Sensor operates with one channel and with measurements are used dry Ag/AgCl electrodes for skin contacts. Connect the GSR sensor as following: 1. Connect the GSR sensor to the Measurement Unit. 2. Attach Ag/AgCl electrodes to fingers as in figure 14-1 shown Figure 14-1: GSR electrode placement The GSR sensor has two short leads that extend from the circuit box. At the end of each lead is an electrode snap similar to those on the extender cables. Place one Ag/AgCl electrode on the palmar side of the index finger and the other on the ring finger, both on the dominant hand. No conductive paste should be used on the electrodes, but fingers should be cleaned with alcohol before sensor placement. N O T E! Use GTF Adapter when connecting to the GSR sensor to ME channel Measurement Unit. 3. Turn on the Measurement Unit. 4. Adjust the signal in MegaWin Signal adjustment The GSR values are not linear and therefore exact the calibration is not possible. Also the resistance value (kohm) is very high the deviation of the ME6000 values is very 41 Mega Electronics Ltd 2009
42 ME6000 Sensor guide for small. As mentioned in the operation principle document the skin conductance readings can vary greatly with environmental factors and skin type Cleaning Figure Resistance of the GSR sensor (kohm) behaves compared to the EMG values (uv) You can clean the sensor using a non-fluffing cloth dampened in cleaning fluid, such as water and mild hand soap solution.! CAUTION Be careful not to rub too forcefully. Do not use alcohol based fluids or corrosive chemicals! Do not sink sensor in the cleaning fluid! 14.5 General instructions The sensor includes sensitive electronics and microprocessor technology. Follow theses general instructions when handling the sensor: Handle the sensor carefully. Be careful not to drop the sensor on the hard surface. Do not wash the sensor with water and avoid extremely high humid conditions. Recommended maximum use of 30 minutes in humid place (relative humidity over 80%) without proper protection ( e.g. water proof kit). Do not expose to temperatures under 0 C /32 F /273K or above 50 C / 122 F / 323K without proper isolation. Do not open any of the sensor parts. When disconnecting the sensor from the Measurement Unit, pull at the connector. Do not pull at the cable and do not rotate the connector. Mega Electronics Ltd
43 Order code TIDAL VOLUME SENSOR 15.1 General description 15.2 Connecting the sensor Tidal Volume Sensor is intended for tidal voluntarily volume monitoring in biofeedback applications and scientific research. Connect the Tidal Volume sensor as following: 1. Connect the Sensor Mass Airflow Sensor (AWM720P1 Airflow) and Mask (PerformaTrak SE ) 2. Connect the Tidal Volume sensor to the Measurement Unit 3. Attach the Tidal Volume sensor (mask) to test subject Mask Sensor AWM720 ME6000 Figure 15-1: Tidal Volume Sensor N O T E! Use GTF Adapter when connecting to the Tidal Volume Sensor to ME channel Measurement Unit. 4. Turn on the Measurement Unit 43 Mega Electronics Ltd 2009
44 ME6000 Sensor guide for N O T E! The sensor is not linear (output voltage vs. airflow). User should take this into consideration when doing analysis from the measurements Cleaning! CAUTION Follow additional instructions provided with the mask.! WARNING The mask may not be suitable for persons with the following conditions: impaired cardiac sphincter function, excessive reflux, impaired cough reflex, and hiatal hernia. It should not be used if the subject is uncooperative, obtunded, unresponsive, or unable to remove the mask. If the test subject experiences skin irritation, consult the physician General instructions The sensor includes sensitive electronics and microprocessor technology. Follow theses general instructions when handling the sensor: Handle the sensor carefully. Be careful not to drop the sensor on the hard surface. Do not wash the sensor with water and avoid extremely high humid conditions. Recommended maximum use of 30 minutes in humid place (relative humidity over 80%) without proper protection ( e.g. water proof kit). Do not expose to temperatures under 0 C /32 F /273K or above 50 C / 122 F / 323K without proper isolation. Do not open any of the sensor parts. When disconnecting the sensor from the Measurement Unit, pull at the connector. Do not pull at the cable and do not rotate the connector. Mega Electronics Ltd
45 Order code FORCE / PRESSURE SENSOR 16.1 General description The Force/pressure sensor is designed to detect force/pressure focused to the sensor placed on the subjects. The Force/pressure sensors are to be placed on the test subject (for ex. underneath the feet or on the thumb). PreAmp 1 ch Force Sensors 2 ch PreAmp Me6000 Figure Force/pressure sensor The Force/pressure sensor is typically used in one or two channel amplifier cable. Sensor has connection pins for connection to the amplifier cable Connecting the sensor Connect the Force/pressure sensor as following: 6. Place the sensors on the body part of the patient. 7. Secure the sensors to the surface (for most cases it is recommended to use standard medical double sided adhesive tape). 8. Connect amplifier cable to the Measurement Unit. 9. Turn on the Measurement Unit. 10. Adjust the signal in MegaWin. 45 Mega Electronics Ltd 2009
46 ME6000 Sensor guide for 16.3 Signal adjustment In order to obtain true force values is recommended to perform two point calibration prior to the force measurement. This can be made by using two known weight as the reference values. Run the measurement and place the weight 1 on the sensor and give marker. Remove the weight 1 and place weight 2 on the sensor and give marker. Remove the weight and stop the measurement. Weight 1 = 1 kg Weight 2 = 10 kg Following, you should calibrate the signal in MegaWin PC Software by using those two measured level measured with weight1 and 2. On how to calibrate the signal in MegaWin, please refer to chapter 5 in this Manual and full MegaWin User s Manual Cleaning You can clean the sensor by wiping it with cloth damp with soapy water. To disinfect the sensor use disinfectant instead of soap.! CAUTION Do not use solvents, acidic or strong alkaline materials. Also, do not sink the Sensor or the Preamplifier in fluid. When cleaning or disinfecting, the sensor must be disconnected from the Measurement Unit General instructions Handle the Set parts carefully. Be careful not to drop on hard surfaces. Do not wash with water and avoid extremely high humid conditions. Recommended maximum use of 30 minutes in humid place (relative humidity over 80%) without proper protection ( e.g. water proof kit). Do not expose to temperatures under 0 C /32 F /273K or above 50 C / 122 F / 323K without proper isolation. Do not open any of the Set s parts. When disconnecting the adapter from the Measurement Unit, pull at the connector. Do not pull at the cable and do not rotate the connector. When not in use place the Set in its box. Mega Electronics Ltd
47 Order code MAINTENANCE AND SERVICE 17.1 Calibration Additional sensors contain sensitive electronics and microprocessor technology. Please follow the maintenance and calibration instructions. You should inspect the System parts regularly. If there is visible damage, it is best to have it repaired at your local distributor or Mega Electronics Ltd. In general, the System is calibrated at the factory and it does not require regular calibration. However, signal adjustment might be required for each sensor separately prior to each measurement. Please check the relevant chapter for your sensor/s. It is recommended to perform an overall system calibration check every 12 months. For more information see the Technical Manual or contact your local dealer.! WARNING Do not try to open any of the devices, sensors, Power Sources and other sealed parts of the system. Only technical personnel, authorized by Mega Electronics Ltd, are allowed to open these parts, subject to the instructions given by Mega Electronics Cleaning You can clean the sensors by wiping them with damp cloth. You can also use alcohol to clean the surface of the sensors.! CAUTION When cleaning or disinfecting the sensor must be disconnected from the Power Source and any peripherals Getting assistance When contacting your local dealer or Mega Electronics with a problem please have the following information available in advance: Part model and serial number. Detailed description of the problem. PC type, model and other systems that may be installed. Operating system in use. MegaWin software version. Error messages. Short description of what you have already checked. If you need to send the device for repair please do the following: 47 Mega Electronics Ltd 2009
48 ME6000 Sensor guide for Inform your contact person in advance. Inform if repair cost estimation is needed. Include all system parts with the shipment (e.g. sensors, preamplifier cables and adapters). Mega Electronics Ltd
49 Order code COMMENTS FOR USE This manual has given you information about the most commonly used ME6000 sensors and the idea how to add new sensor/signal to be used with ME6000 in MegaWin measuring system. By following the instructions written for example Force sensor/signal you are able to add your own sensor. If you need further information about MegaWin and ME6000 device, please, refer MegaWin User s Manual and ME6000 Device manual. Do not change existing configurations, which are used by some protocols. Do not change existing protocol, if you have used it in measurements (corresponding data exist). Make sure that the ME6000 device is turned ON, before you start the measurement. Make sure that the ME6000 communicates with MegaWin, before you start the measurement. You can check it as follows: - Select menu command Options ME6000 Manager - ME6000 Manager Setup window (Connection tab) will be opened - Change tab - If tab change is successful, ME6000 communication is OK 49 Mega Electronics Ltd 2009
EMMA Software Quick Start Guide
EMMA QUICK START GUIDE EMMA Software Quick Start Guide MAN-027-1-0 2016 Delsys Incorporated 1 TABLE OF CONTENTS Section I: Introduction to EMMA Software 1. Biomechanical Model 2. Sensor Placement Guidelines
More information2012 Monitored Rehab Systems E1201 Manual Kneelax. Installation and user manual
2012 Monitored Rehab Systems E1201 Manual Kneelax Installation and user manual Table of contents CHAPTER 1 Installation Manual... 3 1.1 Install Kneelax USB driver... 3 1.2 Detect COM-port... 6 1.3 Software
More informationCURRENT. User Guide ACCESSORIES. External Sensor DT139. for MicroLog EC600 and EC mA ±0.1mA ±3% (before calibration)
External Sensor CURRENT DT139 Range: Resolution: Accuracy: Input impedance: Calibration: OV protection: 0-20mA ±0.1mA ±3% (before calibration) ~170Ω 2 calibration points ±55mA ACCESSORIES User Guide for
More informationrainbow ReSposable Pulse CO-Oximeter Sensor System Training Please see product s Directions for Use for more information 2012 Masimo Corporation
rainbow ReSposable Pulse CO-Oximeter Sensor System Training Learning Objectives At the end of this lesson, the learner will be able to: > Identify key application, inspection and precautionary guidelines
More informationVALENCIA RONDO DOOR WITH RETURN
VALENCIA RONDO DOOR WITH RETURN INSTALLATION GUIDE SEALANT REQUIRED TO COMPLETE THIS INSTALLATION: ( not supplied) Sika Silaflex NG To seal the WHITE shower door and returns to the shower tray. Usage:
More informationVOLTAGE. User Guide ACCESSORIES. External Sensor DT140. for MicroLog EC600 and EC V ±0.05V ±3% (before calibration)
External Sensor VOLTAGE DT140 Range: Resolution: Accuracy: Input impedance: Calibration: OV protection: 0-10V ±0.05V ±3% (before calibration) 3MΩ 2 calibration points ±30V ACCESSORIES User Guide for MicroLog
More informationTOYOTA PRIUS BODY SIDE MOLDING Preparation
Preparation Part Number: PT938-47160-XX Kit Contents Item # Quantity Reqd. Description 1 1 Molding, LH Front Door 2 1 Molding, LH Rear Door 3 1 Molding, RH Front Door 4 1 Molding, RH Rear Door Hardware
More informationTOYOTA YARIS 3 DOOR BODY SIDE MOLDING Preparation
Preparation Part Number: PT938-52110-XX Kit Contents 1 1 Molding, LH Front Door 2 1 Molding, LH Rear Panel 3 1 Molding, RH Front Door 4 1 Molding, RH Rear Panel Hardware Bag Contents 1 2 Additional Items
More informationPrint Head Installation Guide
Print Head Installation Guide MCS Raptor 6 (MCS Eagle AMS Software) is copyright of MCS Incorporated. 2015 MCS Incorporated. 1 Contents Tools... 4 Warnings... 4 Introduction... 4 Section One - Pillar Installation...
More informationSensor Array. Multi-Electrode Mapping Vest. Technical Manual
Sensor Array Multi-Electrode Mapping Vest Technical Manual Explanation of packaging and product symbols Refer to the package label and product to see which symbols apply to this product. Item Description
More informationVALENCIA CORNER DOOR WITH RETURN
VALENCIA CORNER DOOR WITH RETURN INSTALLATION GUIDE SEALANT REQUIRED TO COMPLETE THIS INSTALLATION: ( not supplied) Sika Silaflex NG To seal the WHITE shower door and returns to the shower tray. Usage:
More informationUser s Guide. RP7000 Series Active Probe. Dec RIGOL Technologies, Inc.
User s Guide RP7000 Series Active Probe Dec. 2012 RIGOL Technologies, Inc. Guaranty and Declaration Copyright 2011 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information RIGOL is a registered
More informationTOYOTA CAMRY & CAMRY HV BODY SIDE MOLDING Preparation
Preparation Part Number: PT938-03120-XX Kit Contents 1 1 Molding, LH Front Door 2 1 Molding, LH Rear Door 3 1 Molding, RH Front Door 4 1 Molding, RH Rear Door Hardware Bag Contents 1 2 Additional Items
More informationHP Designjet HD Scanner and T1200 HD Multifunction Printer
HP Designjet HD Scanner and T1200 HD Multifunction Printer Introductory information USB 2.0 high-speed certified Introductory Information Other sources of information The User s Guide for your scanner
More informationHappy Link Software INSTRUCTION MANUAL
Happy Link Software INSTRUCTION MANUAL 101001E-3 HAPPY Contents Regarding this software Normal Operation -------------------------------------------------------------------------------------------------
More informationCreo Revolve Tutorial
Creo Revolve Tutorial Setup 1. Open Creo Parametric Note: Refer back to the Creo Extrude Tutorial for references and screen shots of the Creo layout 2. Set Working Directory a. From the Model Tree navigate
More informationLPK1550 Hydraulic Crimping Tool 15-ton
SERVICE MANUAL LPK1550 Hydraulic Crimping Tool 15-ton Serial Code FYF Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register
More informationOPERATOR S MANUAL FOR DMS 300-4A HOLTER ECG RECORDER
OPERATOR S MANUAL FOR DMS 300-4A HOLTER ECG RECORDER WARNING Only a physician can order a Holter ECG test. WARNING Only the ordering physician can decide on the application technique used for affixing
More informationEXPENDABLES: Hook Fastener Tape, 2 in, P/N: A-A-55126, CAGE: 58536, NIIN: , (McMurdo PLB s only)
1 406 PLB INSP/ACCEPT REFERENCES: NONE TOOLS/TEST EQUIPMENT: NONE EXPENDABLES: Hook Fastener Tape, 2 in, P/N: A-A-55126, CAGE: 58536, NIIN: 010331734, (McMurdo PLB s only) CONSUMABLES: Marker, Paint, P/N:
More informationCombo Scanner. User Manual
Combo Scanner User Manual I. Unpack the Combo Scanner Backlight Holder Combo Scanner Business card Fixture Photo/Business Card Holder User Manual Quick Installation Guide Note This Combo Scanner supports
More informationENGLISH. Spektikor disposable ECG-indicator
ENGLISH Spektikor disposable ECG-indicator User Manual 1.4-2013 Table of Contents General 2 Warnings 2 Instructions 3 Product Description 3 Using the Device 3 Instructions 4 End of Use 4 Symbols 4 Technical
More informationQUANTUM Qflash T2 / X2 OPERATING INSTRUCTIONS
QUANTUM Qflash T2 / X2 OPERATING INSTRUCTIONS 1.0 DESIGNATIONS T2 AND X2 1. Removable Reflector, two positions Normal and Wide angle. 2. Flash-tube 2A. Modeling Lamp (for Model X2 only) 3. Bounce Head,
More informationAmbir ImageScan Pro 930u. User Guide. High Speed Document Scanner with UltraSonic Misfeed Detection. Ver 1.2. p/n UG930u-1.
Ambir ImageScan Pro 930u High Speed Document Scanner with UltraSonic Misfeed Detection www.ambir.com Ver 1.2 Ambir ImageScanPro 930u Table of Contents Box Contents Installation and Setup Loading Documents
More informationDynamic Stander (21") K130 Product Manual
Dynamic Stander (21") K130 Product Manual Contents Warnings and Important Information 3 Recommended Use 4 Assembly 4 User and Item Dimensions 4 Adjustments 5 Operation 6 Sandals & Wedges 7 Arm Prompt Set
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS Rotary Microtome CUT 4062 / CUT 5062 / CUT 6062 CUT 6062 illustrated above INS1000GB 2012-01-06 Instructions CUT4062 / CUT 5062 / CUT 6062 2 CONTENTS 1. INTENDED USE... 4 2. SYMBOLS...
More informationDynamic Stander (25") K150 Product Manual
Dynamic Stander (25") K150 Product Manual Contents Warnings and Important Information 3 Recommended Use 4 Assembly 4 User and Item Dimensions 4 Adjustments 5 Operation 6 Sandals & Wedges 7 Additional Seat
More information1: Introduction : Caution : Tips for Reading this Manual : Preface : System Highlights : Receiver
1: Introduction....1 1 2: Caution.... 2 2 3: Tips for Reading this Manual....3 3 4: Preface....4 4 5: System Highlights....6 6 6: Receiver..7 7 6.1: Specifications......7 7 6.2: Receiver Operation... 7
More informationWinDIAS 3. Quick Start Guide version 3.2. Delta-T Devices Ltd. Image Analysis System
WinDIAS 3 Image Analysis System Quick Start Guide version 3.2 Delta-T Devices Ltd Overview Note: Not all TWAIN devices will work Page 2 Video Camera Operations 1 Connect camera to PC 2 PC detects camera,
More informationGeneral Help. Last revised: Winter When I try to print something on the computer, it appears to work, but nothing comes out of the printer.
General Help Last revised: Winter 2015 Problem Solution When I try to print something on the computer, it appears to work, but nothing comes out of the printer. See the next item. When I try to print something
More informationExercise Heart Rate Sensor
Instruction Manual 012-12232A *012-12232* PS-2129A Strap Hook Strap Adjuster Red LED Electrodes (not shown) Sensor Connector Snaps Strap Equipment Included Polar WearLink Set (M-XXL) Also Required PASCO
More informationPOWER AMPLIFIER. Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciónes CLIP SIGNAL TEMP PROTECTION POWER
POWER AMPLIFIER Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciónes TEMP PROTECTION POWER A CLIP SIGNAL B ON OFF M Introduction Thank you for purchasing a Yamaha C450/320/160 series
More informationCalibration Instruction Manual Emerson 475 Field Communicator. Manual Revision FC.2
Calibration Instruction Manual Emerson 475 Field Communicator Manual Revision FC.2 ABM 2 Wire Radar with HART ABM Sensor Technologies Inc 2013, all rights reserved. Emerson is a registered trademark of
More informationProblem/Procedure Description. Requirements. Problem/Procedure Solution. How-To Document. Updated on: 11/13/2008 By:Christopher Ware
Problem/Procedure Description Performing maintenance on 95s, 95sII and H100 Requirements Ball Bearing Grease (LPKF P/N 106976) Tri-Flow Teflon lubricant aerosol. 3-in-1 Multi-purpose Oil Electronic Component
More informationAppendix B: Autocad Booklet YR 9 REFERENCE BOOKLET ORTHOGRAPHIC PROJECTION
Appendix B: Autocad Booklet YR 9 REFERENCE BOOKLET ORTHOGRAPHIC PROJECTION To load Autocad: AUTOCAD 2000 S DRAWING SCREEN Click the start button Click on Programs Click on technology Click Autocad 2000
More informationSurgical Handpiece. Ti-Max Ti-Max Ti-Max Ti-Max X-SG20L X-SG25L X-SG93L X-SG93. S-Max SG M OM-C0425E
Surgical Handpiece Ti-Max Ti-Max Ti-Max Ti-Max X-SG20L X-SG25L X-SG93L X-SG93 S-Max SG20 09.03.01 M OM-C0425E 001 for X-SG20L,SG20 This handpiece is used only for the Surgical Unit with Torque Calibration
More informationJorVet. Hand-Held Doppler. Operating Manual. Jorgensen Laboratories, Inc. Loveland, Colorado 80538
JorVet Hand-Held Doppler Operating Manual Jorgensen Laboratories, Inc. Loveland, Colorado 80538 Thank You! for choosing the JorVet Hand-Held Doppler! This choice acknowledges the many advantages of the
More informationTable 1. Placing the Sensor in the Sensor Cradle. Step Instruction Illustration
Table 1. Placing the Sensor in the Sensor Cradle Step Instruction Illustration 1. A. Check "U-shaped" Positioner. The number pointing towards the Sensor (1 or 2) must correspond with the Sensor's size.
More informationArbStudio Triggers. Using Both Input & Output Trigger With ArbStudio APPLICATION BRIEF LAB912
ArbStudio Triggers Using Both Input & Output Trigger With ArbStudio APPLICATION BRIEF LAB912 January 26, 2012 Summary ArbStudio has provision for outputting triggers synchronous with the output waveforms
More informationPT-2000series AC/DCcurrentprobe PT-2710 PT-2720 PT-2740 PT-2770 MANUAL INSTRUCTION
PT-2000series AC/DCcurrentprobe PT-2710 PT-2720 PT-2740 PT-2770 INSTRUCTION MANUAL General Safety Instructions: Read the following safety instructions to avoid injury and prevent damage to this product
More informationAutomatic Tool Changer (ATC) for the prolight A Supplement to the prolight 1000 User s Guide
Automatic Tool Changer (ATC) for the prolight 1000 A Supplement to the prolight 1000 User s Guide 1 1995 Light Machines Corporation All rights reserved. The information contained in this supplement (34-7221-0000)
More informationUser Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com
User Manual Digital Compound Binocular LED Microscope Model MD82ES10 MicroscopeNet.com Table of Contents i. Caution... 1 ii. Care and Maintenance... 2 1. Components Illustration... 3 2. Installation...
More informationWS-7136U Wireless 433 MHz Temperature Station. Instruction Manual
WS-7136U Wireless 433 MHz Temperature Station Instruction Manual TABLE OF CONTENTS Topic Page Inventory of Contents 3 Additional Equipment 4 Quick Setup 5-9 Detailed Setup Guide Battery Installation 10-12
More informationDRCR.net Image Acquisition Protocol
DRCR.net Image Acquisition Protocol Optical Coherence Tomography Angiography (OCT-A) Using: Optovue AngioVue Version 3.0 August 14, 2017 DRCR.net OCT-A Optovue AngioVue Procedure Manual 3.0 8-14-17 Table
More informationEcgMove 3. ECG and Physical Activity Sensor User Manual
EcgMove 3 ECG and Physical Activity Sensor User Manual Imprint EcgMove 3 User Manual Version: 14.03.2018 The newest version of the User Manual can be found here: http://www.movisens.com/wpcontent/downloads/ecgmove3_user_manual.pdf
More informationD C 01/2019 3
D-0117968-C 01/2019 3 4 D-0117968-C 01/2019 Screw Driver Screw Driver Unplug both the Red & Blue connectors. (see above) Place a small flat head screw driver on the small orange tabs and push down while
More informationKANEKA OLED Lighting Module SL (LE-01L, LE-02L, LE-03L, LE-01H, LE-02H, LE-03H) Instruction Manual
KANEKA OLED Lighting Module SL (LE-01L, LE-02L, LE-03L, LE-01H, LE-02H, LE-03H) Instruction Manual Safety Information p. 2 1 Product Overview p. 6 2 Connections and Wiring (when dimming is required) p.
More informationTemp. & humidity indicator
Temp. & humidity indicator AH8008 Product Manual www.aosong.com 1 Product Overview AH8008 handheld multi-function temperature and humidity instrumentation consists of two parts: the AH8008 instrument and
More informationQuick Start Guide for the PULSE PROFILING APPLICATION
Quick Start Guide for the PULSE PROFILING APPLICATION MODEL LB480A Revision: Preliminary 02/05/09 1 1. Introduction This document provides information to install and quickly start using your PowerSensor+.
More informationMAXIMIST HVLP TANNING SYSTEM
L0941 12 10:Layout 1 16/12/10 09:03 Page 1 MAXIMIST HVLP TANNING SYSTEM DO NOT USE EQUIPMENT BEFORE READING THIS MANUAL This manual contains important warnings and instructions. Please read these instructions
More informationTel & Fax : Install and Operate Sharp Shape USB3D Foot Scanner Copyright, Sharp Shape, July 2014
12891 Lantana Ave. Saratoga, CA 95070 Sharp Shape not just any shape www.sharpshape.com Tel & Fax : 408-871-1798 Install and Operate Sharp Shape USB3D Foot Scanner Copyright, Sharp Shape, July 2014 The
More informationContents I. APPLICATIONS II. SPECIFICATIONS III. PRINCIPLES IV OPERATION V. MAINTENANCE
Contents I. APPLICATIONS...- 1 - II. SPECIFICATIONS...- 2 - III. PRINCIPLES...- 3 - IV OPERATION...- 9 - V. MAINTENANCE...- 21 - VI SUPPLEMENT...- 23 - Warning: The responsible person must be clear that
More informationS E L E C T I O N. Arm Curl. User manual
S E L E C T I O N T H E S T R E N G T H E V O L U T I O N User manual The identification plate of the and manufacturer, affixed behind the seat, gives the following details: A Name and address of the manufacturer
More informationInstallation Guide Installation Kit for Mounting Philips MP20/30/40/50 on Datex-Ohmeda Aisys Anesthesia Machine
Installation Guide Installation Kit for Mounting Philips MP20/30/40/50 on Datex-Ohmeda Aisys Anesthesia Machine The purpose of this guide is to: 1. Describe mounting of Counterweight (page 2). 2. Describe
More informationGCX Mounting Assembly Installation Guide. Drager Narcomed GS Anesthesia Machines with Philips MP60/70 IntelliVue Patient Monitor Kit
GCX Mounting Assembly Installation Guide Drager Narcomed GS Anesthesia Machines with Philips MP60/70 IntelliVue Patient Monitor Kit Philips MP60/70 IntelliVue Patient Monitor AGM Philips M8048A Flexible
More informationWelcome 1. Precaution
Table of Contents EN Precaution....2 Preparation.. 4 Standard accessories....4 Parts Names & Functions...5 Computer System requirements.... 6 Technical Specifications 7 Install the software.. 7 Start Microscope.8
More information5. Carefully remove the printer from the lower boxed foam support and place it on a solid, level base where it will be used
PROJET 1200 QUICKSTART GUIDE Before you get started you will need: Lint-free paper towels A pair of nitrile gloves Saftety glasses OPENING YOUR PROJET 1200 NOTE: Make sure you save all of your packaging
More informationPRODIM CT 3.0 MANUAL the complete solution
PRODIM CT 3.0 MANUAL the complete solution We measure it all! General information Copyright All rights reserved. Apart from the legally laid down exceptions, no part of this publication may be reproduced,
More informationThe object of these Operating Instructions is to assist you in the correct safe and economical use of the TORSIOMAX torque screwdriver.
Preface The object of these Operating Instructions is to assist you in the correct safe and economical use of the TORSIOMAX torque screwdriver. Target group for these Operating Instructions These Operating
More informationPRORADAR X1PRO USER MANUAL
PRORADAR X1PRO USER MANUAL Dear Customer; we would like to thank you for preferring the products of DRS. We strongly recommend you to read this user manual carefully in order to understand how the products
More informationDraw IT 2016 for AutoCAD
Draw IT 2016 for AutoCAD Tutorial for System Scaffolding Version: 16.0 Copyright Computer and Design Services Ltd GLOBAL CONSTRUCTION SOFTWARE AND SERVICES Contents Introduction... 1 Getting Started...
More informationLifeGear G1 /HOME GYM ITEM NO.: 63100
LifeGear G1 /HOME GYM ITEM NO.: 63100 OWNER S MANUAL IMPORTANT: Read all instructions carefully before using this product. Retain this owner s manual for future reference. The specifications of this product
More informationStuduino Icon Programming Environment Guide
Studuino Icon Programming Environment Guide Ver 0.9.6 4/17/2014 This manual introduces the Studuino Software environment. As the Studuino programming environment develops, these instructions may be edited
More informationModule 2: Radial-Line Sheet-Metal 3D Modeling and 2D Pattern Development: Right Cone (Regular, Frustum, and Truncated)
Inventor (5) Module 2: 2-1 Module 2: Radial-Line Sheet-Metal 3D Modeling and 2D Pattern Development: Right Cone (Regular, Frustum, and Truncated) In this tutorial, we will learn how to build a 3D model
More informationPalmGauss SC PGSC-5G. Instruction Manual
PalmGauss SC PGSC-5G Instruction Manual PalmGauss SC PGSC 5G Instruction Manual Thank you very much for purchasing our products. Please, read this instruction manual in order to use our product in safety
More informationeflex 75x/300x Digital Microscope with Flexible Neck User Guide
eflex 75x/300x Digital Microscope with Flexible Neck User Guide Table of Contents Important information... 4 Product description... 4 Computer requirements... 5 Windows based PC... 5 Mac OS based PC...
More informationTechnical description
STAHLWILLE Standard Manoskop 721 Service Manoskop 730 List of contents Technical description... 27 ã=important safety points... 30 Operation... 32 Maintenance... 42 Cleaning the Manoskop... 47 Accessories...
More informationINSTRUCTION MANUAL INF Fax: (503)
INSTRUCTION MANUAL INF151 1-800-547-5740 Fax: (503) 643-6322 www.ueiautomotive.com email: info@ueitest.com Introduction Congratulations on your purchase of the INF151 infrared thermometer. Like all UEi
More informationWS-7212NU Wireless 433 MHz Weather Station. Instruction Manual
WS-7212NU Wireless 433 MHz Weather Station Instruction Manual TABLE OF CONTENTS Topic Page Inventory of Contents 3 Additional Equipment 4 Quick Setup Guide 5-9 Function Keys 5 Detailed Set-up Guide 10-15
More informationLaser LA-4P. Operating instructions
Laser LA-4P GB Operating instructions A 1 2 3a 5 3c 3b 3a 4 11 11 6 10 7 14a 14b 14c 12 9 8 B C 2. 1. D E F Ø 50mm - 115 mm Ø 2-4,5 G I K s > 6m > 20ft L M N P1 Q O 13 P2 GB Operating instructions The
More informationRead and be familiar with this manual before operating or servicing this device. To ensure operator, technician, and patient safety, use only as
Read and be familiar with this manual before operating or servicing this device. To ensure operator, technician, and patient safety, use only as specified in this manual. Product Manufacturer: Medical
More informationI E D DIN EN ISO 9001 I T Y S Y S T E M. Reg. Nr
HZR HZR - Projecting Part III Start-up, Maintenance and Repairs 2. Editon We automate motion Q U A L C E R T DIN EN ISO 9001 I T Y I F I E D S Y S T E M Reg. Nr. 36 38-01 Parker Hannifin GmbH & Co. KG
More informationCEC VIBRATION TRANSMITTER
CEC 1-808 VIBRATION TRANSMITTER Operation & Maintenance Manual 746 Arrow Grand Circle Covina, CA 91722 United States of America Tel: (626) 938-0200 Fax: (626) 938-0202 Internet: http://www.cecvp.com E-mail:
More informationInstallation Guide. Overview
Installation Guide Thank you for selecting a DuctSox SkeleCore Pull-Tight with Track System. This guide will be helpful for installing the system. The key to a successful SkeleCore Pull-Tight installation
More informationTOYOTA COROLLA EC REARVIEW MIRROR Section I Installation Preparation
Section I Installation Preparation Part Number: PT374-02030 Section I Installation Preparation Kit Contents Item # Quantity Reqd. Description 1 1 AD Mirror Assembly w/compass & Maplights 2 1 Hardware Bag
More informationMaxiMist SprayMate Pro HVLP TANNING SYSTEM
MaxiMist SprayMate Pro HVLP TANNING SYSTEM DO NOT USE EQUIPMENT BEFORE READING THIS MANUAL This manual contains important warnings and instructions. Please read these instructions carefully and keep for
More informationFlat Sample Holder Part Number
Flat Sample Holder Part Number 990-00403 (Patent Pending) Operator s Manual Copyright 2016 Gamry Instruments, Inc. April 8, 2016 988-00043 Rev. 1 If You Have Problems Please visit our service and support
More informationsouthpaw enterprises, inc.
southpaw enterprises, inc. Instruction Sheet C-STAND 7100 Store these instructions in a safe place or with the enclosed maintenance checklist Take time to familiarize yourself with the use and maintenance
More informationMAXIMIST ULTRA PRO HVLP SPRAY TANNING SYSTEM
MAXIMIST ULTRA PRO HVLP SPRAY TANNING SYSTEM DO NOT USE EQUIPMENT BEFORE READING THIS MANUAL This manual contains important warnings and instructions. Please read these instructions carefully and keep
More informationUSER MANUAL. Maxwell Technologies Ultracapacitor Energy Storage Modules. Models: BMOD0058 E016 B02 BMOD0006 E160 B02. Document
USER MANUAL Maxwell Technologies Ultracapacitor Energy Storage Modules Models: BMOD0058 E016 B02 BMOD0006 E160 B02 Document 3000200.1 Notice: The products described herein are covered by one or more of
More informationExperiment HP-23: Lie Detection and Facial Recognition using Eye Tracking
Experiment HP-23: Lie Detection and Facial Recognition using Eye Tracking Background Did you know that when a person lies there are several tells, or signs, that a trained professional can use to judge
More informationVinyl Cutter Instruction Manual
Vinyl Cutter Instruction Manual 1 Product Inventory Inventory Here is a list of items you will receive with your vinyl cutter: Product components (Fig.1-4): 1x Cutter head unit complete with motor, plastic
More informationPipe Laser Model No Instruction Manual
Pipe Laser Model No. 40-6690 Instruction Manual Congratulations on your choice of this Pipe Laser. We suggest you read this instruction manual thoroughly before using the pipe laser. Save this instruction
More informationSupport Tutorial. Project Settings. Adding Bolts. Select: File New. Select: Analysis Project Settings. Select: Support Add Bolt
Support Tutorial 4-1 Support Tutorial Bolts may be added to a RocPlane model to evaluate the effect of support on wedge stability. Bolt orientation can be optimized, or the bolt capacity for a required
More informationOLA2 Open Loop Amplifier. Installation and Operating Manual Release May 2013
OLA2 Open Loop Amplifier Installation and Operating Manual Release May 2013 1 OLA2 - SAFETY INSTRUCTIONS Read this page carefully before installation and use of the instrument, and follow all instructions
More informationSeismometer Preamplifier Manual
Seismometer Preamplifier Manual Seismometer Preamplifier Manual Part number Revision Date Description 13867 1.0 2001-12-18 Initial release Seismometer Preamplifier - Table of Contents 1 Introduction...
More informationA3 Pro INSTRUCTION MANUAL. Oct 25, 2017 Revision IMPORTANT NOTES
A3 Pro INSTRUCTION MANUAL Oct 25, 2017 Revision IMPORTANT NOTES 1. Radio controlled (R/C) models are not toys! The propellers rotate at high speed and pose potential risk. They may cause severe injury
More informationINSTRUCTION MANUAL LKG
INSTRUCTION MANUAL LKG 610 Electrical Safety Analyzer With 10 ECG Connectors 110 Toledo Street Farmingdale, NY 11735 USA Homepage: www.netech.org Dear User, We appreciate your purchase of the LKG 610 Electrical
More informationCrossfire Footswitch. User Guide
Crossfire Footswitch 0475000100 User Guide Contents Warnings and Cautions... 3 Symbol Glossary... 4 Product Description and Intended Use... 6 System Overview...6 Indications/Contraindications...8 Package
More informationOperating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher
Operating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher Model # 100 Standard Model #100-U Heavy Duty CAUTION: Read and Understand
More informationTherAdapt Products Inc. (800) phone (866) fax
TherAdapt Products Inc. (800) 261-4919 phone (866) 892-2478 fax www.theradapt.com Posture Chair Please read all of the following information before using this product. TherAdapt Products Inc. has designed
More informationPatient transport. D.1 Patient table D.1-1. Patient table positions Layout of coil sockets Connections at the patient table
PART C.2 D D.1 D.1-1 Description positions Layout of coil sockets Connections at the patient table Operation Controlling the patient table Triggering/releasing the Table Stop Marking the slice for measurement
More informationHeart Rate Exercise Sensor Product Number: ENEXRT-A298
imagine explore learn Heart Rate Exercise Sensor Product Number: ENEXRT-A298 Overview Understanding how the heart works is basic to biology studies and is one of the first experiments any science student
More informationTM5. Guide Book. Hardware Version: 2.00 Software Version: 1.62
TM5 Guide Book Hardware Version: 2.00 Software Version: 1.62 ii Release Date : 2017-07-10 The information contained herein is the property of Techman Robot Corporation (hereinafter referred to as the Corporation).
More informationInstallation Guide. Overview
Installation Guide Thank you for selecting a DuctSox SkeleCore Pull-Tight with Cable System. This guide will be helpful for installing the system. The key to a successful SkeleCore Pull-Tight installation
More informationMedRx Avant Polar HIT AH-I-MPHITS-5 Effective 11/07/11
INSTALLATION MANUAL 2 Contents Getting To Know Your AVANT POLAR HIT TM... 4 Setting up the System... 6 Software Installation... 7 Driver Installation Windows 7... 10 Driver Installation Windows XP... 13
More informationQUICK CONNECT SYSTEM IMPACT DRIVER ATTAChMENT www.blackanddecker.com.au Australia BDCMTI-XE New Zealand PARTS AND FEATURES 1. Impact Driver attachment 2. 6.35 mm (1/4 ) hex quick-release chuck 2 1 Additional
More informationS E L E C T I O N. Vertical Traction. User manual
and S E L E C T I O N T H E S T R E N G T H E V O L U T I O N User manual and and The identification plate of the and manufacturer, affixed behind the backrest, gives the following details: A Name and
More informationModule 1C: Adding Dovetail Seams to Curved Edges on A Flat Sheet-Metal Piece
1 Module 1C: Adding Dovetail Seams to Curved Edges on A Flat Sheet-Metal Piece In this Module, we will explore the method of adding dovetail seams to curved edges such as the circumferential edge of a
More informationMAXIMIST ULTRA PREMIER HVLP SPRAY TANNING SYSTEM
MAXIMIST ULTRA PREMIER HVLP SPRAY TANNING SYSTEM DO NOT USE EQUIPMENT BEFORE READING THIS MANUAL This manual contains important warnings and instructions. Please read these instructions carefully and keep
More information3 Emergency Breakaway Coupling
SM64227 July 2008 Applicable addition manuals: N/A Aerospace Group Conveyance Systems Division Carter Ground Fueling Maintenance & Repair Manual 3 Emergency Breakaway Coupling Model 64227 Table of Contents
More information