NH Plastic Bases. NH Plastic Bases IEC NH FUSE BASES FEATURES & BENEFITS APPLICATIONS STANDARDS TECHNICAL DATA OVERVIEW

Size: px
Start display at page:

Download "NH Plastic Bases. NH Plastic Bases IEC NH FUSE BASES FEATURES & BENEFITS APPLICATIONS STANDARDS TECHNICAL DATA OVERVIEW"

Transcription

1 NH Plastic Bases FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC NH FUSE BASES FEATURES & BENEFITS NH fuse-bases are available for delivery in single-pole and three-pole designs and can be closely mounted in parallel rows. Each three-pole base is upplied with two phase-partition walls. NH fuse-links plugon covers which clip onto the contact springs can also be supplied for these bases. Plastic fuse-bases sizes 00 to 3 have a single-part plastic base while size 4 has a metal baseplate with 2 ceramic bases. The stable silver-plated contact springs are made of electrolytic copper and formed from one piece. Separate springing is provided by highly resilient captive steel springs, making the contact invulnerable to high thermal stress. Size 4 NH fuse-bases are designed for size 4 fuse-links with 8 mm contact blades. A microswitch (0VAC/10A, terminal size.3x0.8mm) can be used with NH fuse-links with striker, it operates when fuse melts or where there is no fuse-link. Indirect touch protection fuse bases: no microswitch possible. Rated impulse withstand voltage U imp : kv / 8kV (sizes 00 / 0-4) TECHNICAL DATA OVERVIEW Voltage AC 90 VAC Voltage DC 440 VDC Ampere Range (A) A Size per Standard 00, 0, 1, 2, 3, 4 Number of Poles 1-pole, 2-poles, 3-poles, 4-poles Polyamide insulating bases Silver-plated contacts High-pressure spring contacts Screw or rail mounting Connecting cable: 50mm Multipolar bases possible by direct linkage in 00 size and with separator accessory in sizes 0, 1, 2 and 3 Variety of options for protecting active parts through use of accessories: separating plates, separator, cover shields and fuse cover Dual cable-connection system on 00 size: by screw or clamp APPLICATIONS For fuse-links with rated voltages up to 90VAC and 440VDC STANDARDS IEC 029 Compliance Dimensions in accordance with DIN 4320 DIN VDE 03-2, EP.MERSEN.COM 1

2 PRODUCT RANGE NH Plastic bases Size 00-10A (power acceptance: 12W) Number of poles/ phases Connection Installation mode Package Weight BB001EPBR BB003EPV- BLOC Type EP (square contacts) BB001EP F Screw Screw kg BB00EPBT T Clamp Screw kg BB001EPBR F Clamp DIN rail kg BB001EPR R Screw DIN rail kg BB001EPR-BR G Screw / Clamp DIN rail kg BB001EPBR-R H Clamp / Screw DIN rail kg BB002EP A Screw Screw kg BB002EPB D Clamp Screw kg BB002EPR F Screw DIN rail kg BB002EPBR T Clamp DIN rail kg BB003EPB W Clamp Screw kg BB003EPVBLOC W Screw Screw kg BB003EPBR C Clamp DIN rail kg BB003EPRBLOC V Screw DIN rail kg BB004EP S Screw Screw kg BB004EPB R Clamp Screw kg BB004EPR Z Screw DIN rail kg BB004EPBR M Clamp DIN rail kg BB01EP Indirect touch protection IP 20 BB001FS M Screw Screw kg BB001RFS S Screw DIN rail kg BB003SFSBLOC T Screw Screw kg BB003RFSBLOC S Screw DIN rail kg NH Plastic bases Size 0-10A (power acceptance: W) Number of poles/phases Connection Installation mode Package Weight Type EP (square contacts) BB01EP B Screw Screw kg BB01EPR S Screw DIN rail kg BB02EP C Screw Screw kg BB02EPR P219 2 Screw DIN rail kg BB03EP G Screw Screw kg BB03EPR C Screw DIN rail kg BB04EP Q Screw Screw kg BB04EPR J Screw DIN rail kg Type PP (clip contacts) BB01PP N Screw Screw kg BB01PPR T Screw DIN rail kg BB02PP B Screw Screw kg BB02PPR G Screw DIN rail kg BB03PP G Screw Screw kg BB03PPR W Screw DIN rail kg BB04PP R Screw Screw kg BB04PPR H Screw DIN rail kg Indirect touch protection IP20 BB01PPFS X Screw Screw kg BB01EPRFS G Screw DIN rail kg BB03PPFS Z Screw Screw kg BB03EPRFS J Screw DIN rail kg EP.MERSEN.COM 2

3 PRODUCT RANGE NH Plastic bases Size 1-0A (power acceptance: 32W) Number of poles/phases Connection Installation mode Package Weight BB11PP Type PP (clip contacts) BB11PP E Screw Screw kg BB11PPR A Screw DIN rail kg BB12PP F Screw Screw kg BB12PPR G Screw DIN rail kg BB13PP Y Screw Screw kg BB13PPR Y Screw DIN rail kg BB14PP X Screw Screw kg BB14PPR H Screw DIN rail kg Indirect touch protection IP20 BB11FS V Screw Screw kg BB11PPRFS P Screw DIN rail kg BB13PPRFS Q227 3 Screw DIN rail kg NH Plastic bases Size 2-400A (power acceptance: 45W) Number of poles/phases Connection Installation mode Package Weight BB21PP BB31PP Type PP (clip contacts) BB21PP F Screw Screw kg BB21PPR E Screw DIN rail kg BB22PP S Screw Screw kg BB22PPR V Screw DIN rail kg BB23PP B Screw Screw kg BB23PPR D Screw DIN rail kg BB24PP C Screw Screw 1 2. kg BB24PPR R Screw DIN rail 1 2. kg Indirect touch protection IP20 BB21PPFS C Screw Screw kg BB21PPRFS R Screw DIN rail kg BB23PPFS D Screw Screw kg BB23PPRFS S Screw DIN rail kg NH Plastic bases Size 3-30A (power acceptance: 0W) Number of poles/phases Connection Installation mode Package Weight Type PP (clip contacts) BB31PP W Screw Screw kg BB31PPR X Screw DIN rail kg BB32PP D Screw Screw kg BB32PPR B Screw DIN rail kg BB33PP H Screw Screw kg BB33PPR F Screw DIN rail kg BB34PP L Screw Screw kg BB34PPR K Screw DIN rail kg Indirect touch protection IP20 BB31PPFS E Screw Screw kg BB31PPRFS T Screw DIN rail kg BB33PPFS F Screw Screw kg BB33PPRFS V Screw DIN rail kg EP.MERSEN.COM 3

4 PRODUCT RANGE NH Plastic bases Size 4 type P (clip contacts) fuse bases - 10A Number of poles/phases Connection Installation mode Package Weight BB41P W Screw Screw kg NH Plastic bases for NH fuse-links with striker Size Rated current In Number of poles/ phases Connection Installation mode Package Weight For NH fuse-links with striker BB01PPMS T A 1 Screw Screw / DIN rail kg BB11PPMS Q A 1 Screw Screw / DIN rail kg BB21PPMS D A 1 Screw Screw / DIN rail kg BB31PPMS H A 1 Screw Screw / DIN rail kg TECHNICAL DATA Size 00 Size 0 Size 1 Size 2 Size 3 Size 4 Installation mode M screw M screw M8-10 screw M8-10 screw M8-10 screw - Tightening torque (on base) Standard cable terminal Tightening torque (max.) Tightening torque (recommended) 4Nm 14-17Nm 14-17Nm 14-17Nm 14-17Nm - M8 (screw) M5 (clamp) 12Nm (screw) 3,9Nm (clamp) 8-10Nm (screw) 3-3,9Nm (clamp) M8 M10 M10 M12 M1 13,2Nm 32Nm 32Nm 40Nm Nm 27-32Nm 27-32Nm 27-32Nm - EP.MERSEN.COM 4

5 NH00-EP clamp ± 1.5 ± ± 0.5 Ø ± ± ± ± ± M5 EP.MERSEN.COM 5

6 NH00-EP screw 34 3 ± 0. D ± 1.5 ± ± 0.5 Ø ± 0. Section D - D D 104 ± ± ± 1.5 M8 23 ± EP.MERSEN.COM

7 NH Plastic Bases Size 00 A B C D E F G H I J K L M N O P Q R Size 0 to 3 SIze A B C D E F G H I J K L M N O P Q R S 0-EP M PP M PP M PP M PP M EP.MERSEN.COM 7

8 NH4 301 ± ± 1 2 screw M12 (8) min. C 43 ± screw M1 5 4x 8 min ± ± 1 30 ± ± ± 1 Ø 14 ± ± 1 A 3 A EP.MERSEN.COM 8

9 NH Plastic Bases Fuse-bases 90V for HRC fuse-links NH with striker Size A B C NH NH NH NH Reference A B C M Q A N A B P F B Terminal for NH Bases EP.MERSEN.COM 9

10 NH Plastic Bases Cover/shrouds for cable termination BB00TS Design Package Weight BB00TS BB0TS BB1TS BB2TS BB3TS M2213 K L Y21121 X g 24.1 g 51. g 53.3 g 0.1 kg Size 00 Size 0 Size 1 Size 2 Size 3 Covers/protective covers for tags BB00COV Design Package Weight BB00COV BB0COV BB1-2COV BB3COV G F K21491 R g 28.3 g 48.3 g 58 g Size 00 Size 0 Size 1-2 Size 3 ACCESSORIES EP.MERSEN.COM 10

11 ACCESSORIES Phase barriers Design Package Weight BB00CL BB001BLOC B23385 Size 00-3 poles 2 20 g BB00CL W21254 Size g BB0CL Z2139 Size g BB1-2PPCL J21490 Sizes 1 & g BB3PPCL Q Size g Varieties of cable termination Design Package Weight BORNEABF95 BORNEABF150 BORNEABF240 BORNEABF50D BORNEABF95D BORNEABF150D BORNEABF240D A N A B2198 P2215 F22303 B cable Size min. - max.: 10mm - 95mm 1 cable Size min. - max.: 1mm - 150mm 1 cable Size min. - max.: 50mm - 240mm 2 cables Size min. - max.: mm - 50mm 2 cables Size min. - max.: 10mm - 95mm 2 cables Size min. - max.: mm - 150mm 2 cables Size min. - max.: 95mm - 240mm kg kg kg kg kg kg kg BBPAK0 Auxiliary Switches Multipole assembly Design Rated current In Package Weight MSBB01 X Size 0 10 A 1 39 g MSBB11 Y Size 1 0 A 1 41 g MSBB21 J Size A 1 41 g MSBB31 B Size 3 30 A 1 33 g Design Package Weight BBPAK0 V21724 Size g BBPAK1-2 N Size g BBPAK3 M Size g EP.MERSEN.COM 11

MULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole

MULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole MULTIBLOC 00.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 00.ST8 comprises NH fuse switch disconnectors for 160A. They are designed for bottom

More information

MULTIBLOC 4a.ST8 Size 4a, 690VAC, 1600A, 690VAC, Design for Bottom Fitting, 1-, 3-pole

MULTIBLOC 4a.ST8 Size 4a, 690VAC, 1600A, 690VAC, Design for Bottom Fitting, 1-, 3-pole MULTIBLOC 4a.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS Touch protection IP 20 Safe on load connection/disconnection in accordance with IEC 609473 The production

More information

Safety switches with slotted hole lever

Safety switches with slotted hole lever Safety switches with slotted hole lever Selection diagram C1 C C C4 C5 Straight slotted hole lever Slotted hole lever at the left Slotted hole lever at the right (without bend) Slotted hole lever at the

More information

FM series position switches

FM series position switches FM series position switches Selection diagram 0 08 0 A A 0 A 0 External rubber gasket External rubber gasket External rubber gasket External rubber gasket 0 69 Round rod, stainless steel Square rod Glass

More information

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Modular equipment. Presentation, standards. Standard contactors TeSys GC Presentation, standards Standard contactors TeSys GC Presentation TeSys GC contactors are designed for use in modular panels and enclosures. These contactors feature: b Easy installation v quick clip-on

More information

400 Va.c., 500 Va.c., 690 V a.c. Rated current I n. 120 ka

400 Va.c., 500 Va.c., 690 V a.c. Rated current I n. 120 ka Low voltage NV/NH knife-blade fuse-links Electrical characteristics Rated voltage U n 00 Va.c., 500 Va.c., 90 V a.c. Rated current I n - 0 A Breaking capacity at 1,1 U n ka Fusing characteristics gg, am,

More information

Technical features table for miniature circuit-breakers SH 200 Series

Technical features table for miniature circuit-breakers SH 200 Series Technical features table for miniature circuit-breakers SH 00 Series Standards Poles Tripping characteristics I n A frequency f Hz insulation voltage U i acc. to IEC/EN 60664-1 V Overvoltage category Pollution

More information

DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE

DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE 87045 LIMOGES Cedex France Tel: (+33) 05 55 06 87 87 Fax: (+33) 05 55 06 88 88 DRIVIA cabinets CONTENTS NTS PAGES 1. Description, use....1 2. Range, equivalence table...1 3. Dimensions...1 4. General characteristics...2

More information

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A The solution for Load break switches > Power distribution. sircm_100_a_1_cat Rotary switch SIRCO M 3 x 100 A Strong points > Total integration. > Wide range of accessories. > Upgradeability. > Compliance

More information

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and

More information

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink AC Solid State Contactor, 1- and 2 poles Zero switching for heating and motor applications Instant-on switching Rated operational current

More information

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Product datasheet Characteristics LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Price* : 107.62 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category

More information

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays FEATURES/BENEFITS Zero-cross models for resistive loads Low zero-cross turn-on voltage Input protection and control LED standard IP20 touch-proof flaps optional Connectors for power wiring and heat sinks

More information

Data sheet. W-Series WDU 10

Data sheet. W-Series WDU 10 The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

Fuse Links NV/NH gg with Striker Pin Dimensions

Fuse Links NV/NH gg with Striker Pin Dimensions D E I A 9,8 G J H l l Fuse Links Electrical characteristics Rated voltage U n Rated current I n reaking capacity U n Melting characteristic ertified In accordance with Dimensions according to Two versions

More information

The series terminals are state of the art based on technical enhancements, changes in power engineering, their applications and properties.

The series terminals are state of the art based on technical enhancements, changes in power engineering, their applications and properties. w TERMINALS SERIES IK6 GENERAL INFORMATION The series terminals are state of the art based on technical enhancements, changes in power engineering, their applications and properties. 402 Since series terminals

More information

Data sheet. W-Series WDU 4 BL

Data sheet. W-Series WDU 4 BL The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Add-on modules DX 3 63A for MCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4.

More information

Datasheet - ZQ Pull-wire emergency stop switches / ZQ 700

Datasheet - ZQ Pull-wire emergency stop switches / ZQ 700 Datasheet - ZQ 700-02 Pull-wire emergency stop switches / ZQ 700 Preferred typ thermoplastic enclosure one-side operation / wire up to 10 m long Release push button Position indicator Large wiring compartment

More information

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil Product data sheet Characteristics LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 -

More information

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00

More information

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en Contactors Series C7, C6, C6, C65 Single pole contactors for battery voltages Catalogue B.en Contactors for battery voltages C7, C6, C6, C65 Series With its proven line of C7 through C65 Series contactors

More information

Datenblatt. W-Series WDU 10

Datenblatt. W-Series WDU 10 The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C),

More information

LR Position Switches TECHNICAL DATASHEET

LR Position Switches TECHNICAL DATASHEET TECHNICA DATASHEET Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 69 contact blocks available actuators available M assembled connector versions Silver

More information

SBE 160 / SBX 175 ORDERING INFORMATION SECTION 3. Touch Safe Interface Minimizes potential contact with live circuits per IEC & IEC 60529

SBE 160 / SBX 175 ORDERING INFORMATION SECTION 3. Touch Safe Interface Minimizes potential contact with live circuits per IEC & IEC 60529 Connectors - up to 175 Amps SBX and SBE connectors can integrate up to 8 auxiliary power / signal contacts along with the two primary power circuits. SBE connectors feature an IEC 60950 touch safe housing

More information

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

Miniature circuit-breakers S 280 UC series. System pro M. Technical data Technical data 11 Robbie Rd. / Avon, MA 02322 T:(508)513-1000 F:(508)513-1100 70 Ernest St. / Providence, RI 02905 T:(401)781-7100 www.controllerservice.com System pro M Prior to connection of aluminum

More information

Data sheet... W-Series WDU 2.5

Data sheet... W-Series WDU 2.5 The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

Data sheet. W-Series WDU 2.5

Data sheet. W-Series WDU 2.5 The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

Data sheet. W-Series WDU 2.5 RT

Data sheet. W-Series WDU 2.5 RT The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

Ω BLOCK. Ω BLOCK - Distribution Blocks

Ω BLOCK. Ω BLOCK - Distribution Blocks Ω LOK Ω LOK - Distribution locks The TEKNOMEG Ω LOK range is quite complete and includes terminal board distribution units, both single block and compact. This allows making distribution units from up

More information

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A Load break switches standards UL and CSA The solution for Load break switches sircm_1_a_1_cat > Power distribution Strong points Function Rotary switch SRCO M 3 x 1 A SRCO M load break switches are compact

More information

38 Series - Relay Interface Modules A

38 Series - Relay Interface Modules A Series - Relay Interface Modules 0.1-2 - 6 A - Relay interface modules for use with PLC systems, mm wide - Sensitive DC coil or AC/DC coil version - Supplied with integral coil - Instant removal of relay

More information

3 - Protection components Circuit-breakers

3 - Protection components Circuit-breakers Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition Product datasheet Characteristics Main Range Product name Product or component type Device short name Contactor application Utilisation category Device presentation Poles description Pole contact composition

More information

[ 21.3 ] 0.84 A [ 13.0 ] 0.51

[ 21.3 ] 0.84 A [ 13.0 ] 0.51 Connectors - up to 175 Amps SBX and SBE connectors can integrate up to 8 auxiliary power / signal contacts along with the two primary power circuits. SBE connectors feature an IEC 60950 touch safe housing

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)

More information

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay Series - General purpose relays - 0 A Features Plug-in mount 0 A General purpose relay.. & pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listed (certain relay/socket

More information

Position switches FM series

Position switches FM series B Position switches FM series Selection diagram 0 08 0 A A 0 A 0 external rubber gasket external rubber gasket external rubber gasket external rubber gasket 69 stainless steel round rod square rod fiber

More information

MINIATURE DIAZED NEOZED CYLINDER Mini fuses in five sizes to 20 Amps. SQUARE BODY Square body fuses for semiconductor

MINIATURE DIAZED NEOZED CYLINDER Mini fuses in five sizes to 20 Amps. SQUARE BODY Square body fuses for semiconductor TABLE OF CONTENTS MINIATURE DIAZED NEOZED CYLINDER Mini fuses in five sizes to 20 Slow Blow Medium Blow Fast Blow Super Fast Blow "Bottle" fuses in five sizes to 200 gl/gg - Slow Blow - Fast Blow Compact

More information

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications Circuit Breakers FAZ / FAZ6 Installation Products for Industrial Applications Optimum and powerful protection for every application FAZ up to 15 ka IEC/EN 60947-2 up to 10 ka IEC/EN 60898 up to 10 ka UL

More information

SBE 320 / SBX 350 Connectors - up to 350 Amps

SBE 320 / SBX 350 Connectors - up to 350 Amps Connectors - up to 350 Amps ORDERING INFORMATION SBX and SBE connectors can integrate up to 8 auxiliary power / signal contacts along with the two primary power circuits. Sequencing within auxiliary positions

More information

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60 Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60 Zero switching (RM1A) or instant-on switching (RM1B) AC Solid State Relay Direct copper bonding

More information

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts ALPHA AS Modular Distribution Boards /2 Introduction Unequipped Distribution Boards /4 Modular distribution boards / Add-on parts Assembly Kits for Unequipped Distribution Boards /6 8GK4 assembly kits

More information

Relay interface modules A

Relay interface modules A 4C SЕRIES Relay interface modules 8-10 - 16 A Escalators Road / tunnel lighting Hoists and cranes Carousel warehouses Control panels Panels for electrical distribution FINDER reserves the right to alter

More information

Subject to changes 11/2003 Page 1/7

Subject to changes 11/2003 Page 1/7 Main Characteristics: Zero switching. LED display. Various connection systems. Plug-in control terminal. Degree of protection IP 2. Double-insulated design. General Data: Standards / Approvals DIN EN 697--3

More information

Accessories. Accessories

Accessories. Accessories Accessories Accessories Voltage transformer Voltage transformer Powerful and precise Input, 3-pole Output is 3-pole + N Use in IT networks without neutral line For reducing the measurement voltage for

More information

Datenblatt. W-Series WDU 2.5

Datenblatt. W-Series WDU 2.5 The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12 48 Relay interface modules 8 A 48 2 CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12 2 CO 8 A s Relay with forcibly guided contacts according to EN 50205 Type 35 mm rail (EN

More information

Amphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics

Amphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics Amphenol C 1-1 / C 1- Circular Circular Connectors Connectors Amphenol-Tuchel Electronics C 1-1 Overview No. of contacts + PE + PE Termination screw solder Wire gauge Rated insulation voltage Current carrying

More information

Datasheet WPDB Power Distribution Blocks

Datasheet WPDB Power Distribution Blocks Datasheet WPDB Power Distribution Blocks Now you can manage multiple load connections and a wide range of wire sizes with Weidmuller s Power Distribution blocks. By using the best materials and the best

More information

Control Stations ø 22

Control Stations ø 22 Control Stations ø 22 CONTROL STATIONS - NON-ILLUMINATED Technical Info (p. 103) MUSHROOM HEAD Ø 40 - MAINTAINED Push-turn to reset Part Number M16/20 47.9 25.7 Ø 40 Red NC EMERGENCY STOP LBX10510 Red

More information

Semiconductor contactors, Solid-state relays

Semiconductor contactors, Solid-state relays Semiconductor contactors, Solid-state relays Content Benefits and advantages... 338 Approvals and marks... 338 Semiconductor contactors... 339 Ordering details... 339 R100.xx, single-phase... 339 R300.xx,

More information

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil Product data sheet Characteristics LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Datasheet WPDB Power Distribution Blocks

Datasheet WPDB Power Distribution Blocks Datasheet WPDB Power Distribution Blocks Now you can manage multiple load connections and a wide range of wire sizes with Weidmuller s Power Distribution blocks. By using the best materials and the best

More information

EuroMag Series PCB Mount Terminal Blocks. EM3123 Series Euro-Mag Terminal Blocks 3.50 Centers; Modular. Part Numbering System

EuroMag Series PCB Mount Terminal Blocks. EM3123 Series Euro-Mag Terminal Blocks 3.50 Centers; Modular. Part Numbering System EuroMag PCB Mount Terminal Blocks EM.0 Centers; Modular Rating: A, 00V Center Spacing: 0. (.0mm) Wire Range: #1- AWG Housing Material: Black Polyamide Type /, V0 Screw Size: M.0 Chromate Steel Operating

More information

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2 Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EU Low Voltage Directive 2014/35/ EU and the Electromagnetic Compatibility (EMC)

More information

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60 Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60 Zero switching (RM1A) or instant-on switching (RM1B) AC Solid State Relay Direct copper bonding

More information

Controls Contactors and Contactor Assemblies Special Applications

Controls Contactors and Contactor Assemblies Special Applications Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for

More information

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil Product data sheet Characteristics LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 -

More information

SBE 80 / SBO 60 Connectors - up to 80 Amps

SBE 80 / SBO 60 Connectors - up to 80 Amps Connectors - up to 80 Amps SBE and SBO connectors build on the capability of the two pole SB connectors by offering up to 8 auxiliary power / signal contacts along with an IEC 60950 touch safe housing.

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(24V60HZ) Catalog No. 276390 Eaton Catalog No. XTRE10B22B6 Delivery program Product range DILA relays Application Contactor relays Description Basic devices

More information

Characteristics 5 TeSys k contactors and reversing contactors

Characteristics 5 TeSys k contactors and reversing contactors 90 Characteristics contactors k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 424 Product certifications LCp and LPp K06 to

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S

More information

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control Caution: Device contains unprotected active pieceparts, Device contains unprotected non-active pieceparts, which may interact with active pieceparts, Touch only after adhering to corresponding safety regulations!

More information

38 Series - Relay interface modules A

38 Series - Relay interface modules A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

The shield (screen) connecting system from WAGO offers high electrical and mechanical safety for very flexible applications.

The shield (screen) connecting system from WAGO offers high electrical and mechanical safety for very flexible applications. The shield (screen) connecting system from WAGO offers high electrical and mechanical safety for very flexible applications. Shield (Screen) Connecting System VOLUME 1 Shield (screen) connecting system

More information

2/2 Introduction. Unequipped Distribution Boards 2/5 8GK1 surface and flush-mounting distribution boards

2/2 Introduction. Unequipped Distribution Boards 2/5 8GK1 surface and flush-mounting distribution boards Siemens AG 010 ALPHA 160 - DIN Wall-Mounted Distribution Boards / Introduction Distribution Boards with Built-In Distribution Board Panels /4 8GK1 surface and flush-mounting with quickassembly kits Unequipped

More information

Current / residual current and voltage transformers. Current / residual current and voltage transformers

Current / residual current and voltage transformers. Current / residual current and voltage transformers Current / residual current and voltage transformers Current / residual current and voltage transformers 1 Overview Current transformer overview DIN rail current transformer with fuse Current transformer...

More information

48 Series - Relay interface modules A. Features

48 Series - Relay interface modules A. Features Series - Relay interface modules 8-0 - 6 A Features & Pole relay interface modules, 5.8 mm wide. Ideal interface for PLC and electronic systems.3 - Pole 0 A.5 - Pole 8 A.6 - Pole 6 A coils or sensitive

More information

Output of three-phase motors at 50 Hz and 400 V

Output of three-phase motors at 50 Hz and 400 V RT0, RH Coupling Relays (Interfaces) Description DC operation IEC 0 947 and EN 0 947 (VDE 00) The RT0 coupling relays for switching motors and RH for auxiliary circuits are laid out to the special requirements

More information

38 Series - Relay interface modules A

38 Series - Relay interface modules A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

4/2 Introduction. Marshaling Boxes 4/8 8GK1 surface-mounting distribution boards

4/2 Introduction. Marshaling Boxes 4/8 8GK1 surface-mounting distribution boards ALPHA 630 - DIN Floor- Mounted Distribution Boards /2 Introduction Unequipped Distribution Boards /5 8GK1 surface-mounting distribution boards, IP3 /6 8GK1 surface-mounting distribution boards, IP55 Marshaling

More information

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Installation and Operational Instructions for ROBA -switch Type 017._00.2 OBA -switch Type 017._00.2 Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EC Low Voltage Directive 2014/35/ EC and the EMC Directive

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA DATASHEET - DILA-22(230V50HZ,240V60HZ) Delivery program Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(230V50HZ,240V60HZ) Catalog No. 276399 Eaton Catalog No. XTRE10B22F EL-Nummer 0004130208 (Norway)

More information

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage

More information

Complete units: Mushroom heads ø 22mm

Complete units: Mushroom heads ø 22mm Complete units: Mushroom heads ø 22mm MAINTAINED - NON-ILLUMINATED Ø 40 MUSHROOM Push-pull to reset Technical Info (p. 103) Black Bezel Part Number 34.2 Ø 40 Red NC L22DD01-3E01 Red 2 NC L22DD01-3E02 Red

More information

isw switches Control Local control IEC/EN , isw switch with indicator light. IEC/EN , isw switch without indicator light.

isw switches Control Local control IEC/EN , isw switch with indicator light. IEC/EN , isw switch without indicator light. isw switches DB88 PB0566-40 Position contact indication b Suitable for industrial isolation according to IEC/EN 60947-3 standard. b The presence of the green strip guarantees physical opening of the contacts

More information

Specifications Approval Type M12 A-coded HARAX M12-L HARAX M12 L 5 poles shielded M12 Crimp General data Electrical characteristics Materials 03 21

Specifications Approval Type M12 A-coded HARAX M12-L HARAX M12 L 5 poles shielded M12 Crimp General data Electrical characteristics Materials 03 21 M12 A-coding Specifications IEC 60 352-4 Approval A-coding acc. to IEC 61 076-2-101 Circular Connectors Technical characteristics M12 A-coding Type M12 A-coded HARAX M12-L 5 poles HARAX M12 L shielded

More information

Modular Devices and Enclosures

Modular Devices and Enclosures Modular Devices and Enclosures Features Modular contactors for control of motor, heating and lighting applications Digital and Analogue Time Switches for remote command and control of circuits Selectable

More information

Euromas Polymas. Colour: Silver grey, similar to RAL 7001; special colours on request

Euromas Polymas. Colour: Silver grey, similar to RAL 7001; special colours on request Euromas Polymas Detailed product information can be found on www.bopla.de - 5 sizes - Versions with or without screwing systems - Quick-release fastener versions - Transparent lids on request - Terminals

More information

Complete units: Push-buttons ø 22mm

Complete units: Push-buttons ø 22mm Complete units: Push-buttons ø 22mm FLUSH SPRING RETURN - NON-ILLUMINATED Chrome Bezel Part Number Technical Info (p. 103) Black Bezel Part Number 11 Ø 29.9 20.1 19.6 With single position clip Red NC L21AA01-1E01

More information

Coil. Coil L 12 VDC 135 C 18 W 7.7 Ω M M 24 VDC 135 C 18 W 31 Ω M AMP Junior (AJ variant) Coil

Coil. Coil L 12 VDC 135 C 18 W 7.7 Ω M M 24 VDC 135 C 18 W 31 Ω M AMP Junior (AJ variant) Coil s W COILS Type of protection IP 65 Ambient -30 C 60 C F 0.141 kg 42 12 Ø13.25 30 38.6 ISO 4400 (DIN 43650) 17 21.5 20.5 STANDARD irschmann ISO 4400 DIN43650 L 12 VDC 135 C W 7.7 Ω M14000001 M 24 VDC 135

More information

Installation and Operating Instructions for Phase Demodulator Type _.2

Installation and Operating Instructions for Phase Demodulator Type _.2 Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EU Low Voltage Directive 2014/35/EU and the Electromagnetic Compatibility (EMC)

More information

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control Caution: Device contains unprotected active pieceparts, Device contains unprotected non-active pieceparts, which may interact with active pieceparts, Touch only after adhering to corresponding safety regulations!

More information

Contents. Han Hv ES / Han Hv E Technical characteristics Han Hv ES Technical characteristics Han Hv E Han 3 Hv ES

Contents. Han Hv ES / Han Hv E Technical characteristics Han Hv ES Technical characteristics Han Hv E Han 3 Hv ES Contents S / Page Technical characteristics S............................. 04.10 Technical characteristics.............................. 04.11 3 S.............................................. 04.12 3...............................................

More information

General data. Technical data DIKD 1,5. General. Dimensions

General data. Technical data DIKD 1,5. General. Dimensions General data Order number 2715979 Type DIKD 1,5 Barcode number 4017918061722 Unit pack 50 Pcs. Customs tariff 85369010000 Technical data General Number of levels 3 Number of connections 6 Color gray Insulating

More information

Relays and associated toroids

Relays and associated toroids Relays and associated toroids Residual-current protection relay Multi 9 format (DIN rail mount) E92034 E92035 E92036 RH10M. RH21M. RH99M. Multi 9 format (with mounting accessories (1) ) E90249 E90251 E90253

More information

ALPHA DIN Wall-Mounted. Distribution Boards

ALPHA DIN Wall-Mounted. Distribution Boards Siemens AG 008 ALPHA 160 - DIN Wall-Mounted Distribution Boards / Introduction Distribution Boards with Built-In Distribution Board Panels /4 8GK1 surface and flush-mounting with quick-assembly kits Unequipped

More information

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module DATASHEET - DILA-22(24VDC) Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILA-22(24VDC) Catalog No. 276414 Eaton Catalog No. XTRE10B22TD EL-Nummer 4130211 (Norway) Product range DILA

More information

INSTALLATION INSTRUCTION RRU DOUBLE LIGHT POLE MOUNT

INSTALLATION INSTRUCTION RRU DOUBLE LIGHT POLE MOUNT INSTALLATION INSTRUCTION RRU Double Light Pole Mount for installation of two RRU units on mast, towers or other vertical structures. CUE DEE YOUR INNOVATIVE PARTNER 1 CONTENTS 1. PRODUCT COVERED IN THIS

More information

ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR

ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR The flexibility of the Zucchini MS range during planning and installation makes it ideal for frequently changing requirements in small to medium sized commercial

More information

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Installation and Operational Instructions for ROBA -switch Type 017._00.2 Manufacturer s Declaration This product is intended for installation in a machine or system, based on the machine directive 2006/42/EC. It is forbidden to start use of the product until the machine or

More information

No-wear isolation of potentials in terminal block design

No-wear isolation of potentials in terminal block design TERMOPTO Overview No-wear isolation of potentials in terminal block design Space saving solid-state relay with PUSH IN connection technology The TERMOPTO opto modules are characterised by a particularly

More information

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current

More information

Technical data. Contact material: with double break or 2 NC contacts Switching system: A IEC snap action with positive break NC contacts

Technical data. Contact material: with double break or 2 NC contacts Switching system: A IEC snap action with positive break NC contacts Emergency pull-wire switches ZS 71... NA Technical data Contact variations * 63 mm for version 200 N pre-tensioning force To EN 418/IEC 60947-5-5 Metal enclosure 2 contacts Integrated emergency-stop button

More information