1 STANDARD OPEN PATIO COVER (PLEASE NOTE: These are general guidelines, not to be used in lieu of actual code requirements for final design. Your final design will be subject to plan review.) BUILDING & SAFETY DIVISION 110 E. LA HABRA BLVD. LA HABRA, CA Rev. 06/17
2 The Building and Safety Division s counter hours are Monday Friday, 7:30 a.m. 1:00 p.m. and by appointment only from 1:00 p.m. :00 p.m. Closed on alternate Fridays. The staff includes: Chief Building Official Dennis McCreary Senior Building Inspector Ron Shanks Senior Permit Clerk Nayaly Casillas Permit Clerk Lauren Davis Prior to the submittal of building plans for plan check review, verify all usable yard area and setback requirements. Do so by submitting a scaled plot plan, to be reviewed by the Planning Division over the counter, showing the proposed location of your patio addition and yard dimensions including setbacks from property lines and adjacent walls. Plan check review for patio covers is normally done over the counter. Please provide three sets of plans for review and approval. Plan check fees and permit fees are based on the job valuation (there is a minimum job valuation based on the square footage). For an estimate on fees, please contact the permit clerks. Be prepared to give the square footage of your addition. Owner builders shall submit an Owner Builder Declaration Form at the time of permit issuance. This form and the permit application can be downloaded from our website: ALLOWABLE WORKING HOURS FOR CONSTRUCTION ACTIVITY La Habra Municipal Code Section limits construction noise to the following days and hours: 7:00 a.m. to 8:00 p.m., Monday through Saturday All construction activities are prohibited on Sundays and City observed Federal holidays. Those holidays include: New Year s Day, President s Day, Memorial Day, Independence Day, Labor Day, Veteran s Day, Thanksgiving Day and Christmas Day. Construction noise regulations also apply to site improvement activity, building construction, trucks, vehicles, and equipment that are making deliveries, loading or transferring materials, equipment service and maintenance of any devices or appurtenances at or adjacent to any construction project. The City of La Habra will aggressively enforce these noise control measures. Violators may be issued citations. All persons involved with your project should be advised of these regulations. Questions regarding construction hours should be directed to the Building and Safety Division at (62)
3 PLEASE NOTE: This information Bulletin is made available to assist you in preparing for obtaining permits. These are general guidelines, not to be used in lieu of actual code requirements for final design. Your final design will be subject to plan review. DEFINITION Patio covers are one-story, roofed structures not more than 12 feet above grade and used only for recreational or outdoor living purposes, not as carports, garages, storage rooms, or habitable rooms. Patio covers must be open on two or more sides for not less than 6% of the wall area below a minimum of 6 8 of each open wall, measured from the floor. The open sides must not be covered with any permanent materials which obstruct the free passage of light and air, except insect screening, or approved, translucent or transparent plastic, not more than.12 inch (3.2 mm), in thickness, glass conforming to the provisions of chapter 2 (tempered) or any combination of these. If two sides are open, the open sides may be partially enclosed by solid walls which do not exceed 30 inches in height above the floor, in addition to the screening (see drawings in this information bulletin). When required windows from adjoining rooms open into a patio cover, however, open area equivalent to the requirements of Appendix H, Section 102 of the California Residential Code apply. Patio covers may be attached or detached, and permitted only as accessory to single-family dwellings or to individual dwelling units in multi-dwelling-unit buildings. Patio covers cannot be used as carports, garages, habitable rooms or storage structures. Detached patio covers must be located a minimum of 10 from any other structure. Other provisions of the zoning code relating to minimum open areas and separation from the property line may apply. Please contact the Planning and Building & Safety Divisions for details related to your specific site plan. CONCRETE MIX The concrete mix for footings must meet the strength of Fc = 2000 psi minimum, or the following: 1 part Portland cement 2 ½ parts sand 3 ½ parts ¾ inch maximum size gravel Not more than 7 gallons of water per sack of cement. LUMBER Lumber shall be Douglas Fir / Larch No. 2 or better. All lumber must be grade marked. POST ANCHORAGE AND BRACING Posts must be anchored at the lower end and by any of the methods noted. They must be braced to the upper end using any of the optional methods shown. Manufacturer s installation instructions must be followed for installation of all connector and anchorage hardware. Decorative-type bracing may be substituted for the above if the same amount of structural bracing is realized. When the load on any single supporting post does not exceed 70 pounds per post, a minimum 3 ½ thick concrete slab on grade may be substituted for the pad footings shown on the typical framing details: Post anchorage to slabs must be the same as to footings. All fasteners (nails, screws, bolts) exposed to the elements are required to be corrosion resistant. LEDGER TO HOUSE ATTACHMENT When it is desired to connect and support one side of the structure by attaching it directly to the house, the rafter spans and main beam sizes will be as shown in the table. However, the main beam may be replaced on the side attached to the house with a ledger the same size as the rafters and fastened to the studs with 3/8 X corrosion resistant lag screws with washers, spaced at 16 on-center. Attachment to existing house rafters is achieved with optional method shown (See Details A & B of Sheet ). ROOF COVERING If covered with nominal half-inch exterior roof sheathing, the roof must have rafters spaced not more than 2 center to center. Maximum spacing for rafters supporting plywood decks shall be in accordance with spans shown on the structural panel. When used, plastic roof coverings must be installed according to manufacturer s recommendations and the corrugations should be placed perpendicular to and across the supports. All roof coverings (including plastic) must be minimum class B rated for flame spread. Roof slope must be specified on plans. Roof Live Load = 10 psf, minimum. Roof Dead Load = 7 psf, minimum, or actual weight of materials. NOTE: BUILDERS OF STEEL AND ALUMINUM PATIO COVERS, THE CITY OF LA HABRA REQUIRES TRACK AND LEDGER INSPECTIONS. 1
4 DIRECTIONS 1. Do not use pencil or red ink. 2. If framing plan is different from shown in this form, use an additional page (or pages) to show the framing plan. 3. Submit the following: a. Three copies of the site plan b. Three copies of this form. Complete both sides. c. Building permit application form. ***NOT TO SCALE*** GUIDELINES FOR PATIO CONSTRUCTION (Choose one that best fits your condition) Single Family Zero Lot Line Condominium* Town House* *REQUIRES HOA APPROVAL Beam Span Table A Beam Span Table A Rafter Spacing Table B D C & D A & B Rafter Span Table B SECTION Beam Ledger Beam Rafter Post 6 8 Min A, B & C Existing House FRAMING PLAN PATIO COVER REQUIREMENTS 1. Beam: Beam shall be Single Beach Double Beam 2. Rafter: Rafter shall be X at on center. Single Rafter Double Rafter 3. Roof Sheathing: Sheathing shall be self spaced.. Ledger: Ledged shall be a X mounted on existing wall with 3/8 x lag bolts at 16 on center. (See detail A of sheet ).. Fascia: Existing fascia, if used as a ledger, must be attached to the existing rafters with metal framing anchors on each side of each rafter. (See detail B of sheet ). 2
5 Table A MINIMUM HEADER SIZES Rafter POST SPACING (SEE FRAMING PLAN) Span 6'-0" 8'-0" 10'-0" 12'-0" 1'-0" 16'-0" 18'-0" 20'-0" '-0" "X" "X6" "X6" "X6" "x8" "x8" "x8" "x10" 6'-0" "X" "X6" "X6" "X6" "x8" "x8" "x10" "x10" 8'-0" "X" "X6" "X6" "X6" "x8" "x10" "x10" "x12" 10'-0" "X6" "X6" "x8" "x8" "x8" "x10" "x10" "x12" 12'-0" "X6" "X6" "x8" "x8" "x10" "x10" "x12" "x12" 1'-0" "X8" "x8" "x8" "x10" "x10" "x10" "x12" "x1" 16'-0" "x8" "x8" "x10" "x10" "x10" "x10" "x12" "x1" 18'-0" "x10" "x10" "x10" "x10" "x12" "x12" "x1" "x1" 20'-0" "x10" "x10" "x12" "x12" "x12" "x12" "x1" "x1" Table B MINIMUM RAFTER SIZES Rafter RAFTER SPACING (Center to Center) Span 12" 16" 2" 32" 6'-0" 2"x" 2"x" 2"x" 2"x" 7'-0" 2"x" 2"x" 2"x" 2"x" 8'-0" 2"x" 2"x" 2"x" 2"x" 9'-0" 2"x" 2"x" 2"x" 2"x" 10'-0" 2"x" 2"x" 2"x" 2"x6" 11'-0" 2"x" 2"x" 2"x6" 2"x6" 12'-0" 2"x" 2"x6" 2"x6" 2"x6" 13'-0" 2"x6" 2"x6" 2"x6" 2"x6" 1'-0" 2"x6" 2"x6" 2"x6" 2"x8" 1'-0" 2"x6" 2"x6" 2"x6" 2"x8" 16'-0" 2"x6" 2"x6" 2"x8" 2"x8" 17'-0" 2"x6" 2"x6" 2"x8" 2"x8" 18'-0" 2"x6" 2"x6" 2"x8" 2"x10" 19'-0" 2"x8" 2"x8" 2"x8" 2"x10" 20'-0" 2"x8" 2"x8" 2"x8" 2"x10" NOTES: *After prolonged periods of time 2 rafters spanning more than 8 feet, minimum, deflect permanently and give an objectionable appearance. It is, therefore, recommended that for rafter spans exceeding 8 feet, a minimum rafter size of 2 x 6 be used. Table C MINIMUM SQUARE FOOTING SIZES Post RAFTER SPAN (SEE CROSS SECTION) Spacing 6'-0" 8'-0" 10'-0" 12'-0" 1'-0" 16'-0" 18'-0" 20'-0" '-0" 12" sq 12" sq 12" sq 12" sq 12" sq 12" sq 1" sq 1" sq 6'-0" 12" sq 12" sq 1" sq 1" sq 1" sq 16" sq 16" sq 16" sq 8'-0" 1"sq 1"sq 1"sq 16" sq 16" sq 18" sq 18" sq 20" sq 10'-0" 1"sq 16" sq 16" sq 18" sq 18" sq 20" sq 20" sq 22" sq 12'-0" 16" sq 16" sq 18" sq 20" sq 20" sq 22" sq 22" sq 2" sq 1'-0" 16" sq 18" sq 20" sq 20" sq 22" sq 22" sq 2" sq 2" sq 16'-0" 18" sq 20" sq 20" sq 22" sq 2" sq 2" sq 27" sq 27" sq 18'-0" 20" sq 20" sq 22" sq 2" sq 2" sq 27" sq 27" sq 30" sq 20'-0" 20" sq 22" sq 2" sq 2" sq 27" sq 27" sq 30" sq 30" sq Table D1 Roof Sheathing Plywood Min. 1/32" CDX Table D2 Lattice 2"x2" Self Spaced Spans 2"x" Self Spaced Spans On Edge 6'-0" 11'-0" 3
6 X Post X Post (Not naturally durable or pressure treated.) Adjustable Post Base (AB ) 8 Minimum or Naturally durable species or pressure treated. Minimum 3 ½ Concrete Slab Adjustable Post Base (CB ) 1 Minimum Standoff - Per manufacturer s instructions dry pack with concrete after post installation. MIN. Wedge anchor, epoxy anchors, or other approved devices 8 Min. A SLAB FOOTING Min. 6 mil. (.006 inch) polyethylene sheeting, impervious moisture barrier. 12 Min. 12 Min. Table C ***NOT TO SCALE*** B PAD FOOTING x Post Column Base (CB ) W/ 2-/8 Dia. Machine Bolts Roof Sheathing See Table D: Pre-Fab Pier or Cast in place Concrete Pier 2 X Rafter See Table B 8 Min. All fasteners to be corrosion resistant. 16 Min. Header See Table A T-Strap (or Strap Tie) W/ 6-1/2 Dia. Machine Bolts. 16 Square Minimum L- Strap (OL Strap Tie) W/ ½ Dia. Machine Bolts, through bolted, with nuts and washers as required for the bolt sizes. C PIER FOOTING D HEADER: ELEVATION
7 ***NOT TO SCALE*** Corrosion Resistant Fasteners Roof Sheathing See Table D Exterior Stud Wall Exterior Stucco 16 Max. 3/8 X Corrosion Resistant Lag 16 o.c. FACE 16 Max. 1 Minimum 2 X Ledger, minimum width to match rafters. SECTION Existing Residence Roof Overhang A LEDGER DETAIL A3 on Each Side of each rafter Roof Sheathing See Table D NOTE: 1. Standard Joist Hanger ***All existing structural lumber used to support the new patio cover must be structurally sound (i.e. without termite damage, dry rot, or other decay).. Existing 2 X Fascia 2 X Ledger See Note 1 ½ Dia Machine 16 o.c. Rafter See Table B B EAVE CONNECTION SECTION
8 ***NOT TO SCALE*** X Post Roof Sheathing See Table D Continuous 2 X Blocking W/16d 8 o.c. Alternate 2 o.c. Double 2 X Rafter See Table B 2 ½ X 6 Machine Bolts with Flat Washers Each Side Header See See Table A Post Cap (PC ) For x 2 X Rafter See Table B X Post X Post C HEADER DETAIL D HEADER DETAIL PLEASE PROVIDE THREE SETS OF PLANS (SITE PLAN AND CONSTRUCTION DETAILS) FOR REVIEW AND APPROVAL. Patio Enclosure Requirements Three sets of site plans with construction details required for review by Planning and Building & Safety Departments. CRC Appendix H. Enclosure walls are permitted to be any configuration, provided the open or glazed area of the longer wall and one additional wall is equal to at least 6% of the area below a minimum of 6 8 of each wall, measured from the floor. Exterior openings required for light and ventilation shall be permitted to open into a patio structure conforming to Section AH101, provided that the patio structure shall be unenclosed if such openings are serving as emergency egress or rescue openings from sleeping rooms. Where such exterior openings serve as an exit from the dwelling unit, the patio structure, unless unenclosed, shall be provided with exits conforming to the provisions of Section R311 of this code 6
9 INSTRUCTIONS 1. Show project address, owners name, north arrow and scale 2. Show accurate footprint of all existing and proposed structures Owner: Address: City: State: Zip: 3. Show driveway. Show all property lines (P.L.), label each and properly dimension. Show dimensions of proposed structures(s) 6. Show setbacks from property lines to proposed structure(s) Notes: 1. Have correct legal description and address of property. 2. Note adjoining streets or alleys and width of curb cuts. 3. Note location of each auto parking spaces.. North arrows should be correctly placed.. Draw completely dimensioned lot plan. 7
Typical Deck Details
Botetourt County guard decking ledger board fasteners existing house floor construction guard post attachment ledger board attachment to existing house s footing beam -to-beam connection post-to-beam connection
Typical Deck Details
Based on the 2009 Michigan Statewide Building Code guard decking ledger board fasteners existing house floor construction guard post attachment ledger board attachement to existing house s footing beam
What Plans Do I Need for a Building Permit?
What Plans Do I Need for a Building Permit? 6 CITY OF PORTLAND, OREGON - BUREAU OF DEVELOPMENT SERVICES 1900 SW 4th Avenue, Por tland, Oregon 97201 503-823-7300 www.portlandoregon.gov/bds This brochure
SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION
SECTION R507 DECKS R507.1 Application. The provisions of this section shall provide prescriptive requirements for the design and construction of all uncovered, wood-framed, single-span exterior decks.
ONE AND TWO FAMILY DWELLINGS Uncovered Decks July, 2007
ONE AND TWO FAMILY DWELLINGS Uncovered Decks July, 2007 In the City of Lee s Summit, the construction of uncovered decks with a floor surface more than 30 inches above the adjacent grade level requires
ROOF-CEILING CONSTRUCTION
CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL R801.1 Application. The provisions of this chapter shall control the design and construction of the roof-ceiling system for all buildings. R801.2
CITY OF LOVELAND HOMEOWNERS GUIDE FOR BUILDING PERMITS FOR HOME IMPROVEMENTS
CITY OF LOVELAND HOMEOWNERS GUIDE FOR BUILDING PERMITS FOR HOME IMPROVEMENTS Development Services Department Building Division 500 East Third Street, Suite 110 Loveland, CO 80537 (970) 962-2505 FAX (970)
City of Virginia Beach, Virginia Typical Deck Details
City of Virginia Beach, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code The design details in this document apply to residential, single-level decks only. Construction cannot
IRC 2012 Code Compliant Wood Framed Residential details. Miss Installed Connectors with code references and remedies, discussion.
IRC 2012 Code Compliant Wood Framed Residential details Miss Installed Connectors with code references and remedies, discussion. You can help avoid this, by being diligent with inspections. Notes to Attendees
SECTION ROUGH CARPENTRY
SECTION 06100 ROUGH CARPENTRY PART 1 GENERAL 1.1 DESCRIPTION OF WORK A. The work includes furnishing all labor, materials and equipment required to complete the Rough Carpentry work as shown on the Drawings
2x6. 2x8. 2x10. Size. 2-2x10 8'-5" w/ 2 NJ 7'-3" w/ 2 NJ
1 Rafter Size Spacing Allowable span 24" 11'-9" 24" 2x6 14'-1" 2x4 12" 15'-6" 12" 24" 14'-10" 24" 2x8 18'-2" 2x6 12" 20'-5" 12" 24" 18'-2" 24" 2x10 22'-3" 2x8 12" 25'-8" 12" 24" 21'-0" 24" 2x12 25'-9"
City of Long Beach Department of Development Services Building and Safety Bureau. Wood Frame Prescriptive Provisions For Residential Construction
City of Long Beach Department of Development Services Building and Safety Bureau Wood Frame Prescriptive Provisions For Residential Construction Information Bulletin BU-010 Eff: 01-01-2011 Rev: 07-05-2017
TO WHOM IT MAY CONCERN:
TO WHOM IT MAY CONCERN: A lot of questions are asked throughout the year as to when a building permit is required. This list may help identify some of the instances when a permit would be required: Permit
ROOF-CEILING CONSTRUCTION
CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL R801.1 Application. The provisions of this chapter shall control the design and construction of the roof-ceiling system for all buildings. R801.2
Introducing AJSTM INSTALLATION GUIDE USA. 8 th Edition USA
The SIMPLE FRAMING SYSTEMSM INSTALLATION GUIDE USA for Floors This Installation Guide is intended to provide general information for the designer and end-user. For further information, please refer to
24 X32 3 CAR GARAGE POLE BARN STYLE FRAME
24 X32 3 CAR GARAGE POLE BARN STYLE FRAME 3 ENTRY DOOR 2 WINDOWS, 1 @ EA. END 1-16 X8 GARAGE DOOR 1-9 X8 GARAGE DOOR 4 CONCRETE SLAB 10 WALLS 4/12 PITCH METAL ROOF METAL SIDING INDEX PAGE DESCRIPTION 1
FASTENERS BUILDING DEPARTMENT
FASTENERS BUILDING DEPARTMENT 952-446-1660 WWW.CITYOFMINNETRISTA.COM This handout is intended only as a guide and is based in part on the 2015 Minnesota Residential Code, Minnetrista City ordinances, and
Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side
ITEM 1 DESCRIPTION OF BUILDING ELEMENTS Blocking between joists or rafters to top plate, toe 2 Ceiling joists to plate, toe 3 4 5 6 Ceiling joists not attached to parallel rafter, laps over partitions,
VERSA-LAM BCI INSTALLATION GUIDE LIMIT STATES DESIGN CANADA
INSTALLATION GUIDE VERSA-LAM BCI LIMIT STATES DESIGN CANADA The information in this document pertains use in the CANADA ONLY, Limit States Design. Refer the appropriate Specifier Guide US for use in the
ROOFING City of Grand Rapids Building Safety Division
ROOFING City of Grand Rapids Building Safety Division 218-326-7601 www.cityofgrandrapidsmn.com This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Grand
THE ENGINEERED WOOD ASSOCIATION
D A T A F I L E APA Performance Rated Rim Boards A rim board is the wood component that fills the space between the sill plate and bottom plate of a wall or, in second floor construction, between the top
Collins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY
PART 1 GENERAL 1.1 RELATED SECTIONS SECTION 061000 ROUGH CARPENTRY A. Drawings and general provisions of the Construction Contract, including General Conditions and Division 1 Specification Sections, apply
RESIDENTIAL BUILDING PERMIT REQUIREMENTS
RESIDENTIAL BUILDING PERMIT REQUIREMENTS Before a building permit is issued for any new construction, addition or accessory building, the following items must be supplied to the Building Inspector for
Beam & Header Technical Guide. LP SolidStart LVL. 2900F b -2.0E. U.S. Technical Guide U.S. TECHNICAL GUIDE
U.S. Technical Guide U.S. TECHNICAL GUIDE LP SolidStart LVL & Header Technical Guide 2900F b -2.0E Please verify availability with the LP SolidStart Engineered Wood Products distributor in your area prior
STRUCTURAL ATTACHMENTS
Brace Structural Attachment Selection Procedure ) Determine structure to be attached to from the following: A) Concrete B) Wood Beam C) Structural Steel 2) Reference structure connection type from Appendix
Re-Roofing Policy SPECIAL REQUIREMENTS AND NOTES
CITY OF MANTECA COMMUNITY DEVELOPMENT DEPARTMENT 1001 West Center Street Manteca, CA 95337 FAX (209) 923-8949 Building Safety Division (209) 456-8550 Planning Division (209) 456-8500 Public Works/Engineering
Cap & Trim Framing Guide
Cap & Trim Framing Guide Note: We do not sell framing or ridge flashing material, shop local. Introduction: Focus is on wood framing, but frames can also be fabricated from steel or aluminum. Layout is
How to Build Good Decks..
How to Build Good Decks.. Worldwide Sleeping Company, Inc Cary, North Carolina Decking Overview.. Decking Overview.. more Decking Joist.... Joist Hanger Ledger Lag Screw House Wall Decking House Floor
Exterior Wall Fastener Schedule
City of Republic Community Development Department Exterior Wall Fastener Schedule REVISION DATE: JANUARY 2017 Design and construction (2012 IRC Section R602.3): Exterior walls of wood frame construction
CURVED ROOF ASSEMBLY INSTRUCTIONS ATTACHED VERANDAH. Your supplementary guide to building an ATTACHED CURVED ROOF VERANDAH or PATIO BEFORE YOU START
ROOF ATTACHED VERANDAH ASSEMBLY INSTRUCTIONS Your supplementary guide to building an ATTACHED ROOF VERANDAH or PATIO This set of instructions should be used in conjunction with the Stratco instruction
TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II
SECTION 061000 - ROUGH CARPENTRY PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The General Conditions, any Supplementary General Conditions and Division 1, General Requirements, are hereby made a part of
Nails, Fasteners, Connectors, and Framing
Nails, Fasteners, Connectors, and Framing Nails To order Nail Sizes Nail length is often referred to as d or penny. For example a 10-D nail or a 10 Penny Nail. Use the following chart for nail length reference.
With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e Download 12,000 More Shed Plans
With Illustrations, Drawings & Step By Step Details Click Here To Download 12,000 Shed Plans 1 P a g e Download 12,000 More Shed Plans Table of Contents OVERVIEW... 3 MATERIALS & CUTTING LISTS... 4 DRAWINGS,
Load Tables, Technical Data and Installation Instructions
W22. W22. W22. W22. W22 W22.. Simpson Strong-Tie Fastening Systems Structural Wood-to-Wood Connections Including Ledgers Designed to provide an easy-to-install, high-strength alternative to through-bolting
PLAN SUBMITTAL REQUIREMENTS
DEPARTMENT OF ECONOMIC AND COMMUNITY DEVELOPMENT BUILDING DIVISION PLAN SUBMITTAL REQUIREMENTS Residential and Commercial Projects Welcome to the South San Francisco Building Division. We are providing
Vertical Offset Base and Safety Rail System Installation Instructions
Section 5 Vertical Offset Base and Safety Rail System Installation Instructions The vertical offset base and safety rail assembly are designed to be used in residential construction for sloped or flat
HOW TO BUILD A 12X8 SHED
HOW TO BUILD A 12X8 SHED With Illustrations, Drawings & Step By Step Details Note: This is a sample plan from RyanShedPlans. All other plans in our collection goes indepth with more details, more instructions,
Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems Overview Revised 9/2/2016
Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems Overview Revised 9/2/2016 SBCA has been the voice of the structural building components industry since 1983, providing
Wood structures Copyright G G Schierle, press Esc to end, for next, for previous slide 1
Wood structures Copyright G G Schierle, 2001-02 press Esc to end, for next, for previous slide 1 Wood Types: Balloon framing (rare) Platform framing Heavy timber framing Advantages: The only renewable
INDEX PAGE RELEASE SECTION NUMBER DATE
INSTALLATION INSTRUCTIONS For Wind Zone 1 (other Wind Zones available on request) Version 11/20/2002 INDEX PAGE RELEASE SECTION NUMBER DATE Approval INTRODUCTION 2 2/26/2001 GENERAL INSTALLATION 3 2/26/2001
Residential Plot Plans
Residential Plot Plans Planning & Development Services/Building Safety Division 1 Riverfront Plaza Ste. 110 Lawrence, KS 66044 (785)832-7700 Fax (785)832-3110 Email: buildinginspections@lawrenceks.org
VERSA-LAM. An Introduction to VERSA-LAM Products
44 VERSA-LAM An Introduction to VERSA-LAM Products VERSA-LAM is one of the strongest and stiffest engineered wood products approved in the UK. 241 302 356 406 VERSA-LAM products are excellent as floor
Engineered Hardwood Flooring Installation Instructions
Engineered Hardwood Flooring Installation Instructions 1 Important Information before You Begin 1.1 Installer/Owner Responsibility Carefully inspect all materials before installation. Materials installed
The better way to build TM. Installation Manual ROOF SIPs
The better way to build TM Installation Manual ROOF SIPs August 2017 ROOF SIPs Installation Manual Table of Contents Topics General Requirements.................................... 3 Materials..............................................
Bedroom Window Egress
edroom Window Egress ( illustrating a double hung style window ) Only 1 egress window per bedroom required 18 Total clearance of this Window closed Window open window is 7.5 square feet 25 % more then
Open Lattice tube Patio Cover- Basic Installation Guidelines
Before You Begin: DOUBLE HEADER/DOUBLE RAFTER Open Lattice tube Patio Cover- Basic Installation Guidelines 1. Take the time to read and understand the basic guidelines before opening or starting your patio
Best Barns. 10' x 16' the Elm R. Assembly Book. revised September 29, 2016
Best Barns Assembly Book revised September 29, 2016 the Elm R 10' x 16' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive - Greenville, PA 16125 This manual is copyrighted. Under the
Professional Quality FOR THE Professional Contractor. Marketing Offerings. 225 Elm Ave Galt, Ca bmdusa.com
Professional Quality FOR THE Professional Contractor Marketing Offerings Header Boards Professional Quality FOR THE Professional ContraCtor ID: QBHB3614 14" PVC Board Proudly Distributed by 36" Professional
SECTION TRAFFIC SIGNAGE
SECTION 10 14 53 TRAFFIC SIGNAGE PART 1 - GENERAL 1.01 SECTION INCLUDES A. Furnishing and installing roadside traffic signage. B. Providing additional traffic signs as required in Sections 01 55 28 Controlling
COMPACT DECK. Compact Deck SOUTHERN FOREST PRODUCTS ASSOCIATION SOUTHEASTERN LUMBER MANUFACTURERS ASSOCIATION
COMPACT DECK SOUTHERN FOREST PRODUCTS ASSOCIATION SOUTHEASTERN LUMBER MANUFACTURERS ASSOCIATION P.O. BOX 641700 KENNER, LA 70064-1700 (504) 443-4464 FAX (504) 443-6612 www.southernpine.com Compact Deck
PAINT & MISC. Notes. Table of Contents. Front Handrail Posts Front Handrails Closet Shelving Exterior Deck...
118 PAINT & MISC. Table of Contents Front Handrail Posts... 119 Front Handrails... 122 Closet Shelving... 125 Exterior Deck... 127 Look for painter s tape on the hammer drill for where to set the depth.
TRADITIONAL GABLE ATTACHED PATIO AND CARPORT. Your complete guide to building an ATTACHED Outback TRADITIONAL GABLE PATIO or CARPORT
TRADITIONAL GABLE ATTACHED PATIO AND CARPORT STRATCO OUTBACK ASSEMBLY INSTRUCTIONS. Your complete guide to building an ATTACHED Outback TRADITIONAL GABLE PATIO or CARPORT BEFORE YOU START Carefully read
Building permit application requirements for prefabricated. aluminum awnings and patio/deck covers for single and two family
Planning and Building Department INFORMATIONAL GUIDE Building permit application requirements for prefabricated aluminum awnings and patio/deck covers for single and two family dwellings The purpose of
Best Barns USA Assembly Book
Best Barns USA Assembly Book Revised September 19, 2017 the Woodville 10' x 12' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 This manual is copyrighted. Under
Monterey. 10,12 and 14 Oval Gazebo Instructions
1000 Ternes Drive Monroe, MI 48162 Toll Free 1-800-437-0784 - BEFORE YOU BEGIN - Always wear OSHA-APPROVED safety glasses throughout assembly process First... Read these instructions thoroughly before
Residential Room Additions
Residential Room Additions The purpose of this information sheet is to provide information regarding building code and permit processing requirements for RESIDENTIAL ROOM ADDITION(S) in the City of Poway.
TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL
ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL The ProTEC panels are manufactured with grooves on all four sides to accept the steel components. This grooving applies to the regular panel whose
Build your own Cherrypine pergola with the coloured timber that lasts
Build your own Cherrypine pergola with the coloured timber that lasts Easy to understand instructions Clear illustrations Simple step by step guide Great handy tips Cherry Pine Design 1. Plan Draw the
Lodge II Pergola. Manual and Installation Instructions. Please read these instructions before removing parts from crate
Lodge II Pergola Manual and Installation Instructions Please read these instructions before removing parts from crate Introduction Thank you for your purchase from The Outdoor GreatRoom Company. This pergola
Wall bracing is one of the most important structural elements of
CONTINUINGEDUCATION Wall Bracing and the Codes Introduction Wall bracing is one of the most important structural elements of any house, but it can also be one of the most confusing, because designing houses
Sonoma Outdoor Kitchen Pergola. Assembly Instructions
Sonoma Outdoor Kitchen Pergola Assembly Instructions Introduction Thank you for your purchase from The Outdoor GreatRoom Company. This pergola has been engineered and manufactured in the USA. This user
With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e Download 12,000 More Shed Plans
With Illustrations, Drawings & Step By Step Details Click Here To Download 12,000 Shed Plans 1 P a g e Download 12,000 More Shed Plans Table of Contents OVERVIEW... 3 MATERIALS & CUTTING LISTS... 4 DRAWINGS,
CHAPTER TWO Fire Lanes & Fire Access
Contents: CHAPTER TWO Fire Lanes & Fire Access Access Requirements for New Construction Sites Fire Lane Signs and Installations Alternative Fire Lane Signs Fire Lane Identification (Red Painted Curbs)
Product Information & Installation Instructions
Product Information & Installation Instructions TUFF-STRAND TM OSB Sheathing OSB Structural Panels from MARTCO Installation Instructions: Site-Built and Modular Construction Important Notice to Buyers
ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 9 Ventilation Overview Revised
Truck Module Page 1 of 9 INTRODUCTION Each firefighter must have a thorough knowledge of the proper methods used to ventilate a structure. Ventilation itself does not put out fires! However, effective
8 x 10 Timber-frame Garden Shed
8 x 10 Timber-frame Garden Shed Includes: Step-By-Step Instructions, Complete Details & Materials Lists Timber-framing is a traditional building method that uses a simple framework of heavy timber posts
DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF TILES REPORT HOLDER:
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1754 Reissued 11/2017 This report is subject to renewal 11/2018. DIVISION: 07 00
With Illustrations, Blueprints & Step By Step Details Brought To You By ShedPlansz.Com Click Here To Get More Shed Plans
12 X 8 Shed Plans With Illustrations, Blueprints & Step By Step Details Brought To You By ShedPlansz.Com Click Here To Get More Shed Plans Blueprints And Diagrams Instructions For Building The Shed
Article 4 PROCEDURES for PLOT PLAN and SITE PLAN REVIEW
Article 4 PROCEDURES for PLOT PLAN and SITE PLAN REVIEW Section 4.01 Purpose It is the intent of this Article to specify standards, application and data requirements, and the review process which shall
DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:
0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3096 Reissued 01/2017 This report is subject to renewal 01/2018. DIVISION: 06 00 00 WOOD, PLASTICS
Best Barns USA Assembly Book
Best Barns USA Assembly Book Revised September 12, 2017 the Denver 12' x 16' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 This manual is copyrighted. Under the
CITY OF DES MOINES, IA PERMIT AND DEVELOPMENT CENTER 602 Robert D Ray Drive Des Moines, IA Phone:
CITY OF DES MOINES, IA PERMIT AND DEVELOPMENT CENTER 602 Robert D Ray Drive Des Moines, IA 50311 Phone: 515-283-4200 Minor Site Plan list This checklist should be used as a guide in the preparation of
CITY OF BURLINGAME - PLANNING COMMISSION SUBMITTAL REQUIREMENTS RESIDENTIAL DESIGN REVIEW
CITY OF BURLINGAME - PLANNING COMMISSION SUBMITTAL REQUIREMENTS RESIDENTIAL DESIGN REVIEW Application to the must include certain minimum information before a project can be scheduled for a hearing. The
ICC-ES Evaluation Report Issued February 1, 2011 This report is subject to re-examination in one year.
ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-3098 Issued February 1, 2011 This report is subject to re-examination in one year. A Subsidiary of the International Code Council
DIY Shed Guide Planning your Project Easy Step by Step Guide Simple Illustrations Maintenance
DIY Shed Guide Planning your Project Easy Step by Step Guide Simple Illustrations Maintenance The specifications contained within this brochure are for guideline purposes only. For further information
DIVISION 6 WOOD AND PLASTIC
DIVISION 6 WOOD AND PLASTIC UCSC Campus Standards Handbook Rough Carpentry Standards 06100 1 SECTION 06100: ROUGH CARPENTRY STANDARDS A. Provide solid wood blocking behind all toilet and bath accessories,
installation Guide What you don t Safety I-Joist Storage and Handling United states Installation Instructions for Residential Floor Systems
Safety GP Lam lvl installation Guide wood i beam joists. Walking on the joists should not be permitted until they are properly braced. 2. Lateral restraint, such as an existing deck or braced end wall,
A. Submit manufacturer's technical data and installation for each type of sign required.
SECTION 10425 PART ONE GENERAL 1.1 SECTION INCLUDES A. Interior Building Signage. B. Handicapped parking signs. C. Permanent Project Sign. 1.2 DESCRIPTION A. Signage shall consist of room number and room
NEW SINGLE FAMILY HOMES
NEW SINGLE FAMILY HOMES Your submission must include the following to be accepted as a complete application: 1 copy of the deed and / or purchase and sales agreement if you have owned the property less
eco-shake INSTALLATION INSTRUCTION
1 eco-shake INSTALLATION INSTRUCTION NOTE: Shuffling the eco-shakes during installation may be necessary to obtain a uniform color throughout the roof. Due to the natural wood content in the ecoshakes,
Installation Instructions for Standard Lap and Self-Aligning Lap Siding
Installation Instructions for Standard Lap and Self-Aligning Lap Siding 7/16 in. Standard Laps Include: All Old Mill Widths, Cedar Shake Lap and Smooth Lap 1/2 in. Self-Aligning Include: 8 in. and 12 in.
Mailing Address: Fax number: City: State: Zip: Property Owner: City: State: Zip: City: State: Zip:
/ Department of Community Development ARCHITECTURAL REVIEW APPLICATION 73-510 Fred Waring Drive Palm Desert California 92260 (760) 346-0611 Fax (760) 776-6417 Applicant: Telephone: Mailing Address: Fax
ICC-ES Evaluation Report Reissued September 1, 2012 This report is subject to renewal September 1, 2013.
ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1790 Reissued September 1, 2012 This report is subject to renewal September 1, 2013. A Subsidiary of the International Code Council
A. Columns: Worthington Millwork; Cellular Polyvinyl Chloride (PVC) columns; decorative, weatherproof, insect-proof, and highly durable.
WorthingtonWrap PVC Columns Architectural Specifications 1.1 SECTION INCLUDES A. Columns: Worthington Millwork; Cellular Polyvinyl Chloride (PVC) columns; decorative, weatherproof, insect-proof, and highly
DETAILED STILE AND RAIL WOOD DOOR SPECIFICATION
DETAILED STILE AND RAIL WOOD DOOR SPECIFICATION UNIVERSITY CONTACT: Structural Services, Maintenance & Operations (302) 831-8456 PART 1 GENERAL DOORS 1.01 GENERAL PROVISIONS 1. The Drawings and General
Joshua Woodsman
CONSTRUCTION GUIDE of one of our design Please Note This electronic document is protected by the identifier against unauthorized dissemination on the Internet. Before building any structure make sure you
SECTION ASPHALT SHINGLES
SECTION 07311 ASPHALT SHINGLES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Asphalt shingle roofing. 2. Flexible sheet membranes for eave protection, underlayment, and valley protection. 3. Associated
Residential & Industrial Fence
Residential & Industrial Fence Assembly Instructions CONTENTS 02: OVERVIEW & CONTENTS 03: PRODUCT SPECIFICATIONS 04: GETTING STARTED 05: WALL ATTACHMENT & LINE POST ASSEMBLY 06: CORNER POST ASSEMBLY 07:
SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Belmont with pocket doors. Building Size 12'x16' or 12'x20' Revised January 10, 2012
Best Barns USA Assembly Book Revised January 10, 2012 SAMPLE INSTRUCTIONS the Belmont with pocket doors Building Size 12'x16' or 12'x20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive
Outdoor Storage Locker
Easy To Build Outdoor Storage Locker A little shed that spells big relief for a crowded garage Complexity: Simple Cost: $100-$500 Assemble this easy-to-build storage locker for your outdoor tools. It's
DUTCH GABLE FREESTANDING CARPORT
DUTCH GABLE FREESTANDING CARPORT STRATCO OUTBACK ASSEMBLY INSTRUCTIONS. Your complete guide to building a FREESTANDING Outback DUTCH GABLE CARPORT BEFORE YOU START Carefully read these instructions. If
NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING
NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS Reference Guide 0.1 GENERAL 0.1 Reference Guide 0.2 Index 0.3 Disclaimer & Limitations 0.4 General Notes
Flush Mount. SunEarth Flush Mount Installation Manual. SunEarth Flush Mount. Asphalt Shingle Roofing
Flush Mount SunEarth Flush Mount Installation Manual Thank you for choosing the SunEarth flush mount method. It provides a strong durable solution for mounting SunEarth collectors parallel to the roof
12 x 12 Flat Top Pergola
x Flat Top Pergola Model: Freemont A S S E M B L Y G U I D E O P T I O N A L A C C E S S O R Y Bolt Down Bracket Kit ( for Pergola) Ver.-057 Ta b l e o f Co n t e n t s PAGE x Flat Top Pergola Introduction
A ledger/header board is the next step if you are attaching your deck to an existing structure.
CE 101, Spring 2006 Step-by-Step Deck Construction 1 / 7 Step 1 Mark off the deck area using string and "batterboards" (Fig. 2) making sure that it is level and square. The string will help you visualize
TYPICAL STANDOFF GLASS RAIL ELEVATION TYPICAL SECTION RS0B20 WITH RECTANGULAR BACK PLATE TYPICAL STAIRS
Revisions By: CRL SRS STANDOFF RAILING SYSTEM CRL GLASS RAIL S RS0B20 w/ RECTANGULAR BACK PLATE CRL'S GLASS RAIL S CAN BE USED FOR MOUNTING GLASS PANELS UP TO 3/4" (19 MM) IN THICKNESS. THE 4" X 8" (102
HOLLOW CORE PRODUCTS GROUNDED IN STRENGTH
HOLLOW CORE PRODUCTS GROUNDED IN STRENGTH usable space under your garage 8 form - 8 Hollow Core 7' - 11-1/2" 3" min. topping for precast diaphragms 2-3/ 3" MIN. TOPPING FOR PRECAST DIAPHRAGMS 7' - 11-3/4"
1.04 QUALITY ASSURANCE
SECTION 07312 ARCHITECTURAL ASPHALT SHINGLES PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
CUTTING, NOTCHING, AND BORING OF WOOD FRAMING MEMBERS (Unless an alternate design is provided by a licensed Engineer or Architect)
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: 91.2320 Effective: 5-23-00 DOCUMENT NO. P/BC 2002-007 Revised: 2-01-01 Previously Issued As: IB ST-14 CUTTING, NOTCHING, AND BORING OF WOOD
LP SolidStart Laminated Strand Lumber (LSL) and Laminated Veneer Lumber (LVL) Louisiana-Pacific Corporation Revised July 21, 2017
LP SolidStart Laminated Strand Lumber (LSL) and Laminated Veneer Lumber (LVL) PR-L280(C) Louisiana-Pacific Corporation Revised July 21, 2017 Products: LP SolidStart 1.35E, 1.55E, and 1.75E LSL LP SolidStart