O 11/ p"",/ o (0
|
|
- Godfrey Kelley
- 5 years ago
- Views:
Transcription
1 Side View Privacy Fence Pas... Fasten aluminum bracing to post with 2 galvanized lag screws. 1/4" x 2". o (0... nstall 1/8" x 3" aluminum bracing. Against rear wall of house, under window. Fastened to inside face of rear deck band (see details). Length will vary. Bracing to deck band detail O 11/ ptlona : Rep ace exlstlnq lag bolts with through bolts, nuts, washers.> Aluminum bracing Top View Deck band attached to house \c 1/4" galvanized lag screws, 2" long. p"",/ Fence Post See Detail r '\ J ~.:»: \ Deck band attac hed to house o Aluminum bracing PROJECT CLENT DATE Criterium-Giles Engineers Privacy fence stabilization The Townes at Crabtree July 21, Walnut Street The Townes at Crabtree Suite 354 Raleigh, NC Raleigh, NC Cary, NC
2 - Side View Top View Railing Post ---. Optional: Replace existing lag bolts with through bolts, nuts, washers ~ nstall Simpson Strong 1 HL53 Angle as detailed i attached bulletin or simil 1/2 diameter throu; / 1/2 diameter, 4' p / bolts into deck band diameter bolts throu thn e r h bolts long lag OR 1/2 h deck board / Railing Post '--- ~ ~ \ \\ Deck Band Attached to j - '-- '-- """\ '-- NOTE: Drawing not to scale All hardware should be galvanized Through bolt length will vary depending on material Appropriately sized washers should be used with all bolts nstall Simpson Strong Tie DTT2Z Deck Tension Tie as detailed in attached technical bulletin. PROJECT CLENT DATE Criterium-Giles Engineers Railing stabilization The Townes at Crabtree July 21, Walnut Street The Townes at Crabtree Suite 354 Raleigh, NC Raleigh, NC Cary, NC l-. ~, \ j7/~)11 ~. ~ ~. " 1'-O. \'G'N~«:.\:..<t'l... <f: <9: ; ~ ~.~... t::rr c. G...
3 The expiration date of this document has been extended until 12131/11. NEW! DTT2Z Deck Tension Tie ncreasing reports of deck failures across the country have led to a greater focus on deck safety in the building codes. Two areas of concern are the guardrail-post connection and the lateral deck-to-house connection because they are key to the performance of the deck and the safety of the occupants. Simpson Strong-Tie has a new solution to make both of these deck connections stronger and safer: the OTT2Z deck tension tie. The OTT2Z was designed to satisfy code requirements for guardrail-post connections in wood decks. t also meets new RC requirements for laterally attaching the deck to the house and meets provisions of the AF&PA Prescriptive Resid~ntial Wood Oeck Construction Guide (OCA6). The OTT2Z is code listed under CC ESR Versatile and cost-effective, the new Simpson Stronq-Tie" OTT2Z deck tension tie fastens quickly and easily using Simpson Stronq-Tie" Strong-Drive? screws (SOS), which install with no pre-drilllnq and are included with each OTT2Z connector. NECTON Ties the guardrail post into deck framing ronger an sa er an nat s, s or 0 ts Meets provisions set in the nternational Residential Code (RC) for guardrail reinforcement (Table R301.5) Single post-to-deck connection tested for the concentrated load specified in CC-ES acceptance criteria for Handrails and Guards (AC273) ZMAX coating for additional corrosion resistance SMPSON Strong-Tie LATERAL-LOAD CONNECTON Ties the deck into the house for a stronger, safer ledger connection Helps prevent a common type of deck failure Meets provisions set by the 2009 nternational Residential Code (RC) for lateral deck-to-house connections (R ) ZMAX coating for additional corrosion resistance! Plan View of Guardrail Reinforcement Details Typical nstallation to Joist< Typical nstallation to Blocking< < These illustrations address an outward force on the guardrail. An additional OTT2Z can be installed to the lower bolt to resist an inward force. Refer to the technical bulletin T-GRORLPST for other framing conditions Simpson Strong-Tie Company nc. F-DT2Z09 4/09 exp.6-1+
4 DECK -TO-HOUSE LATERAL-LOAD CONNECTON r-v RimlJOiS Dr Shea(hing v Leiger '\ /. Typical Deck-to- Lateral-Load Connection ~ Plan View of Deck-to- Lateral-Load Connection DECK NSTALLATON nstall the OTT2Z to the deck joist or blocking using Simpson Stronq-Tie" Stronq-Drive" screws (SOS) (included). For guardrail-post reinforcement, install a 1/2" diameter machine bolt or threaded rod through the post and into the seat of the OTT2Z. For deck-to-house attachment, use W' diameter threaded rod to connect the two OTT2Zs. A standard cut washer (included) must be installed between the nut and the seat of the OTT2Z for all installations. Simpson Stronq-Tie" Stronq-Drive" screws (SOS) install best with a low-speed, high-torque drill with a hex-head driver. For more information on safe deck building products and practices see our Deck Framing Connection Guide (F-OECKCOOE) or MATERAL: 14 gauge Model No. DTT2Z <t 13;\6 Anchor Diameter 'h FNSH: ZMAX coating Fasteners 8-SDS 1,4"x1Yi' Minimum Wood Member Thickness (in.) Allowable Tension Load 1 (160)2 (100) (160)2 Deflection at Allowable Load' (in.) DF/SP (100) SPF/HF 1'h Load values are valid if the OT2Z is flush with the end of the framing member or installed away from the end. 2. Where noted, allowable loads have been increased up to 60% for short load durations with no further increase allowed. 3. Deflection at highest allowable load includes fastener slip, DT2Z elongation, and bolvrod elongation (L = 6"). Additional elongation of bolt/rod shall be accounted for by the Designer for bolt/rod lengths greater than 6". SHEARWALL NSTALLATON The OT2Z is also suitable for use as a holdown in site-built shearwalls. Meets minimum requirements for many alternate braced wall panels per section R of the 2006 RC (see table R , item 1). nstalls quickly onto a single or double 2x post and attaches to a W' diameter anchor. The OT2Z was tested in accordance with the CC-ES acceptance criteria for Holdowns Attached to Wood Members (AC155). Typical Vertical nstallation for Shearwall Applications NSTALLATON FOR SHEARWALLS nstall OTT2Zto post using the included Simpson Stronq-Tie" Strong-Drive" screws (SOS). A standard cut washer (included) must be installed between the nut and the seat. Refer to the current Wood Construction Connectors catalog for cast-in-place anchorage solutions or for post-installed anchorage solutions see the Anchoring and Fastening Systems for Concrete and Masonry catalog. Simpson Strong-Tie Strono-Drive" screws (SDS) install best with a low-speed, high-torque drill with a hex-head driver. This mer is effective until.j~, and reflects information available as of April 1, 2009, This information is updated periodically and should not be relied upon after JfH8 80, 2t1; contact Simpson Strong-Tie for current nformation and limited warranty or see Simpson snonc-ne Company nc. P.O. Box 10789, Pleasanton, CA FDTZZ094/09 expo SMUm
5 HL Heavy Angles and Gussets connectors/hl.asp HL Heavy Angles and Gussets Versatile angle gussets and heavy angles promote standardization and construction economy, and are compatible with Strong-Tie structural hardware. Finish: 7 ga Models-Galvanized; 3 ga Models-Simpson Strong- Tie gray paint. Options: Gussets may be added to HL models when L;:: 5" (specify G after model number, as in HL46G). '.' Load Table Gallery of images Code Reports Drawings Catalog Page Related Categories Help for downloads Gallery: top roll over images below to see larger image '.' ". HL53 HL55 Typical HL55 nstallation Load Table: See code report listmgs below top These products are available with additional corrosion protection. Additional products on this page may also be available with this option, check with Siropson Strong-lie for details /16/2011 6:57 AM
Designed for Building Designed for Living
decorative hardware Designed for Building Designed for iving (800) 999-5099 strongtie.com Add Beauty and Strength to Your Custom Outdoor iving Structures ith Outdoor Accents, a line of decorative wood
More informationDesigned for Building Designed for Living
Designed for Building Designed for iving decorative hardware Add Beauty and Strength to Your Custom Outdoor iving Structures ith Outdoor Accents, a new line of decorative timber connectors and fasteners
More informationConnectors for Cold-Formed Steel Curtain-Wall Construction
The expiration date of this document has been extended until 2/3/3. Introducing Connectors for Cold-Formed Steel Curtain-Wall Construction Code Listed: IAPMO ES ER-238 (800) 999-5099 www.strongtie.com
More informationCity of Los Angeles RR Values for Connectors in Shear Walls and Wall Anchorage Assemblies
for Connectors in Shear Walls and Wall Anchorage Assemblies The City of Los Angeles Building Code (LABC) has different requirements for holdowns used in shear wall applications than those used in wall
More informationPilot Holes for Manufacturing Purposes (Fastener not required) HDU U.S. Patent 6,112,495; 5,979,130. Vertical Wood Member Thickness.
HDU/DTT2Z Holdowns This product is preferab to similar connectors because of a) easier installation, b) higher loads, c) lower instald cost, or a combination of these features. HDU holdowns are pre-defcted
More information24" max from each end of the ledger. See detail 6A & 6B, typ. both ends IRC R Ledger R507.2
NOTE: All exposed lumber to be pressure treated (P.T.) or decay resistant. Fasteners for P.T. wood shall be hot-dipped galv. or stainless steel, typical. see pages 2 & 5 for footings 8'-0" -10'-0" Beam
More informationLateral Support. Decks over 24 above grade require lateral support* *Exceptions to be discussed later
Lateral Support Decks over 24 above grade require lateral support* *Exceptions to be discussed later Decking Types of Decking: -2x4s & 2x6s -five quarter span rated decking boards -Wood plastic composite
More informationConnectors for Cold-Formed Steel Curtain-Wall Construction
Introducing Connectors for Cold-Formed Steel Curtain-Wall Construction Code Listed: IAPMO ES ER-238 (800) 999-5099 www.strongtie.com Our Newest Product Line for Cold-Formed Steel Framing Simpson Strong
More informationSteel Strong-Wall Shearwall Installations
Steel Strong-Wall Shearwall Installations Connector Training for Contractors Series Name: (800) 999-5099 www.strongtie.com Industry Terms Steel Strong-Wall Every day we work hard to earn your business,
More informationDeck Evaluation Checklist
Date: Reported By: Project Name/Client: Year Deck was Built: I. Stairs A. Not Applicable B. Are there any visible signs of cracks, decay or over-notching? No Yes 1. If yes, where? C. Stairway width: (Hint:
More informationSD Screw #10x2½" 16dx2½" SD Screw #9x2½" SD Screw 10dx1½" 8d Common N54A 0.25" 0.131"
DESIGNED FOR FASTENER TYPES Fastener Types and s Specified for Simpson Strong-Tie Connectors Many Simpson Strong-Tie connectors have been designed and tested for use with specific types and sizes of fasteners.
More informationTENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018
SECTION 055000 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationDECKS. Stairway illumination Positive attachment of ledger Lateral load connection required board (R507.2) required (R ) (R311.7.
DECKS Max. riser height-7 ¾ Min. tread depth-10 Landings required at (R311.7.5.1) (R311.7.5.2) top and bottom of stairs (R311.7.6) Notched guardrail post NOT allowed Graspable handrail required Spacing
More informationSECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION
SECTION R507 DECKS R507.1 Application. The provisions of this section shall provide prescriptive requirements for the design and construction of all uncovered, wood-framed, single-span exterior decks.
More informationTypical Deck Details Based on the City of Nixa Residential Deck Ordinance
Typical Deck Details Based on the City of Nixa Residential Deck Ordinance The use of this package in lieu of submitted drawings applies to Single Span, Single Level, Residential Decks ONLY. Decks must
More informationCall (770) STEP 6: Caulk bolt hole within the bracket for protection from the elements.
Call (770) 777 7007 Structural Deck Support System: Product Numbers: H1-GQ, H2-GCL (Also applies to H1-GK and H2-GCR) STEP 1: Following the spacing guidelines per the deck design and joist layout, mark
More informationICC-ES Evaluation Report
ICC-ES Evaluation Report ESR-6 Reissued April, 009 This report is subject to re-examination in two years. www.icc-es.org (800) 4-6587 (56) 699-054 A Subsidiary of the International Code Council DIVISION:
More informationSTRUCTURAL ATTACHMENTS
Brace Structural Attachment Selection Procedure ) Determine structure to be attached to from the following: A) Concrete B) Wood Beam C) Structural Steel 2) Reference structure connection type from Appendix
More informationTechnical Bulletin US Comparison of Rim to Joist Post Connectors and Surface Mounted Post Anchors
Technical Bulletin US 20120124 Comparison of Rim to Joist Post Connectors and Surface Mounted Post Anchors This technical bulletin will attempt to make as direct a comparison as is possible between the
More informationDeck Design Guide. One and Two Family Residential Dwellings
Deck Design Guide One and Two Family Residential Dwellings The City of Lake Oswego is providing this information to help you design your deck, obtain a building permit and pass inspections. The standards
More informationATI Evaluation Service A Division of Architectural Testing Certification Services
ATI Evaluation Service A Division of Architectural Testing Certification Services Subject to Renewal: 10/13/2016 Issued: 12/17/2014 Visit www.ati-es.com for current status Revised: 06/05/2015 Page 1 of
More informationAttach Trusses and Rafters Faster
Attach Trusses and Rafters Faster SDWC TRUSS Screw Truss/Rafter-to- and Stud-to- Connections (800) 999-5099 www.strongtie.com For Truss/Rafter-to- and Stud-to- Connections The Strong-Drive SDWC TRUSS screw
More informationFASTENERS C O M P AT I B L E W I T H F E R O T I E S Y S T E M S. Which FERO Tie Systems Require Fasteners?
FASTENERS C O M P AT I B L E W I T H F E R O T I E S Y S T E M S Which FERO Tie Systems Require Fasteners? Structural Actions: Fastener,, or Both? With the exception of FERO tie systems that are directly
More informationPART MATERIALS. Section Fencing Materials. Description
PART 03000 - MATERIALS Section 03010 - Fencing Materials Description 03010.00 Scope - This section consists of the test requirements, specifications and tolerances for barbed wire, woven wire and chain
More informationTYPICAL STANDOFF GLASS RAIL ELEVATION TYPICAL SECTION RS0B20 WITH RECTANGULAR BACK PLATE TYPICAL STAIRS
Revisions By: CRL SRS STANDOFF RAILING SYSTEM CRL GLASS RAIL S RS0B20 w/ RECTANGULAR BACK PLATE CRL'S GLASS RAIL S CAN BE USED FOR MOUNTING GLASS PANELS UP TO 3/4" (19 MM) IN THICKNESS. THE 4" X 8" (102
More informationLoad Tables, Technical Data and Installation Instructions
W22. W22. W22. W22. W22 W22.. Simpson Strong-Tie Fastening Systems Structural Wood-to-Wood Connections Including Ledgers Designed to provide an easy-to-install, high-strength alternative to through-bolting
More informationPARTS SIDE PLATE TOP MOUNT BLOCK BOTTOM MOUNT FIRST TREAD SUPPORT TREAD INTERMEDIATE PANEL UPPER CABLE BALUSTER INTERMEDIATE CABLE
ARTS 1 2 3 BLOCK SIDE LATE TO MOUNT 4 5 6 BOTTOM MOUNT FIRST TREAD SUORT TREAD 7 8 9 LOWER ANEL BALUSTER INTERMEDIATE ANEL BALUSTER UER ANEL BALUSTER 10 11 12 LOWER CABLE BALUSTER INTERMEDIATE CABLE BALUSTER
More informationRAIL PANEL AT TRANSITION SECTION PLAN - POST DETAIL PLAN - TUBE SPLICE. Colorado Department of Transportation. Staff Bridge Branch
Limits of pay length for Bridge RailType 10M (For post spacing, see Dwg. No. B ) B60610 (Use with B60610A) 8 min. 1 max. 8 min. 1 max. 10 0 Max. 10 0 Max. post spacing 10 0 Max. 2 5 Post 1 x 1 slotted
More informationSDWH TIMBER-HEX Screw
Simpson Strong-Tie Fastening Systems Structural Wood-to-Wood Connections, Including Ledgers Double-barrier coating provides corrosion resistance equivalent to hot-dip galvanization, making it suitable
More informationOpen Up Your View With CABLE SYSTEMS
Open Up Your View With CABLE SYSTEMS PRESENTED BY CROWN HERITAGE Our Cable Multiple options to accomodate any deck or stair design Marine Grade 316 stainless steel Swaging is the term used for attaching
More informationFLOOR ANCHOR SYSTEM APPLICATIONS L TRACK APPLICATIONS
FLOOR ANCHOR SYSTEM APPLICATIONS Sure-Lok recommends the following for floor anchor system layout and installation. These recommendations are not all-inclusive and may not be applicable to every system
More informationTypical Deck Details
Based on the 2009 Michigan Statewide Building Code guard decking ledger board fasteners existing house floor construction guard post attachment ledger board attachement to existing house s footing beam
More informationCity of Virginia Beach, Virginia Typical Deck Details
City of Virginia Beach, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code The design details in this document apply to residential, single-level decks only. Construction cannot
More informationAttachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems Overview Revised 9/2/2016
Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems Overview Revised 9/2/2016 SBCA has been the voice of the structural building components industry since 1983, providing
More informationSturdi-Wall Design Manual for SW46, SW66, SW63, SW64, SW60, SW83, SW84, and SW80 Models
Sturdi-Wall Design Manual for SW46, SW66, SW63, SW64, SW60, SW83, SW84, and SW80 Models Project Number ME086-05 by Brent Leatherman, P.E. Timber Tech Engineering, Inc E-Mail: bl@timbertecheng.com January
More informationCONTENTS TOOL LIST U P S I D E I N N O V A T I O N S, L L C RAMP AND STEP SYSTEM ASSEMBLY INSTRUCTIONS. Revised: June 2013
U P S I D E I N N O V A T I O N S, L L C RAMP AND STEP SYSTEM ASSEMBLY INSTRUCTIONS TOOL LIST Required Tools: - Reciprocating Saw with Metal Cutting Blade - Drill - 7/16 Drill Bit for Metal Drilling -
More informationAttachment of Residential Deck Ledger to Side of Metal Plate Connected Wood Truss Floor Ladder. Installation Instructions Revised 9/2/2016
Attachment of Residential Deck Ledger to Side of Metal Plate Connected Wood Truss Floor Ladder Installation Instructions Revised 9/2/2016 SBCA has been the voice of the structural building components industry
More informationLateral-Load Connections
Knowledge: Lateral-Load Connections Special hardware is needed to correctly fasten deck joints to interior floor joists BY MARK GUERTN 've been installing lateral-load hardware on my decks for several
More informationTREX PERGOLA INSTALLATION INSTRUCTIONS
RECOMMENDED TOOLS/SUPPLIES: Pencil 4' Level Measuring Tape Framing Square/Speed Square 8' High Step Ladder (Two recommended) Hacksaw or Bolt Cutters Socket Wrench with 9/16" Socket and 3/4" Deep Socket
More informationTESTING THE GUARDRAIL POST TO DECK CONNECTION Michael G. Morse and Daniel P. Walsh P.E.
TESTING THE GUARDRAIL POST TO DECK CONNECTION Michael G. Morse and Daniel P. Walsh P.E. Every deck builder knows full well the risks inherent in their occupation. Most injuries are related to builders
More informationAPPLICATION FOR A BUILDING PERMIT
APPLICATION FOR A BUILDING PERMIT City of San Jacinto 595 S. San Jacinto Ave San Jacinto CA 92583 95.487.7330 fax 95.654.9896 Must print legibly, submit (3) sets of building and plot plans. Fill out all
More informationTHE ENGINEERED WOOD ASSOCIATION
D A T A F I L E APA Performance Rated Rim Boards A rim board is the wood component that fills the space between the sill plate and bottom plate of a wall or, in second floor construction, between the top
More informationFortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.
Installation Instructions for Fortress Horizontal Cable Panel System with UB-05 Brackets and Fe Posts It is the responsibility of the installer to meet all code and safety requirements, and to obtain all
More informationPREPARATION & TOOL CHECK LIST
INSTRUCTION MANUAL RAILING PRODUCTS BEGIN TO AGE AS SOON AS THEY ARE EXPOSED TO NATURE. BUILDINGS EXPERIENCE AGING FACTORS DIFFERENTLY, SO IT IS DIFFICULT TO PREDICT HOW LONG RAILING PRODUCTS WILL LAST.
More informationEquilibrium Credenza
Equilibrium Credenza Cantilevered base & Tapered Credenza Installation Instruction EI0006 Revision A 8/20/18 Equilibrium End User Agreement Enwork Equilibrium credenza bases must be installed directly
More informationHex Head Bolt Set N - Includes lock nut. Used to connect male and female T connectors. Galvanized. 3/4" x 3-1/2". Standard Grade (f) Part #24279
a Standard Grade (3/16 ) and Commercial Grade(1/4 ) Tie Down Is designed for use with 1-1/2" thick lumber (minimum width 6"). All hardware is mounted with 3/8" carriage bolts. All male and female dock
More informationCSS Central Mount System
CSS-20 Installation Manual CSS-20 Safety Notifications Below are the installation instructions for the CSS-20-2 Long Span Beam Mounting System. Please read these safety notifications prior to beginning
More informationSWAY BRACE PIPE ATTACHMENT FIG. 010
Function: Designed for bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system used in conjunction with a PHD Manufacturing structural attachment fitting,
More informationDIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:
0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3096 Reissued 01/2017 This report is subject to renewal 01/2018. DIVISION: 06 00 00 WOOD, PLASTICS
More informationPryda Timber Connectors
Pryda Timber Connectors Pryda Lintel Guide Engineered Steel Wall Lintels March 2014 ESSENTIAL NOTES PRYDA PRODUCT GUIDES INTRODUCTION The information in this Product Guide is provided for use in Australia
More informationConnectors for Cold-Formed Steel Curtain-Wall Construction
Special Section Introducing Connectors for Cold-Formed Steel Curtain-Wall Construction Code Listed: IAPMO ES ER-238 (800) 999-5099 www.strongtie.com 240 Our Newest Product Line for Cold-Formed Steel Framing
More informationPulaski County, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code
Pulaski County, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code The design details in this document apply to residential, single-level decks only. Construction cannot deviate
More informationMudsill Anchorage Systems in Cripple Wall Retrofits
Mudsill Anchorage Systems in Cripple Wall Retrofits By Howard Cook, Contractor Bay Area Retrofit Inc. Wendy Allen P.E Anchorage Systems Field Engineer Simpson StrongTie December 21, 2005 International
More informationEngineering Services Program
GDR41 1214 Product Evaluation Engineering Services Program The following product has been evaluated for compliance with the wind loads specified in the International Residential Code (IRC) and the International
More informationTREX POST MOUNT DECKING AND CONCRETE
TREX POST MOUNT DECKING AND CONCRETE for Pressure-treated Wood Framing LOCATION AND INSTALLATION OF POST MOUNTS IMPORTANT NOTES:» EACH POST MUST BE ATTACHED AS SHOWN TO ENSURE A CODE COMPLIANT AND SAFE
More informationFortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.
Installation Instructions for FortressCable H-Series Cable Panel System With UB-05 Brackets and Fe Posts It is the responsibility of the installer to meet all code and safety requirements, and to obtain
More informationTypical Deck Details
Botetourt County guard decking ledger board fasteners existing house floor construction guard post attachment ledger board attachment to existing house s footing beam -to-beam connection post-to-beam connection
More informationCopyright. magazine. Materials and Deck/Diaphragm Construction
Structural Forensics investigating structures and their components Lateral Load Path and Capacity of Exterior Decks By Brian J. Parsons, Donald A. Bender, P.E., J. Daniel Dolan, P.E., Robert J. Tichy and
More informationLateral Tension System
FASTENMASTER TECHNICAL BULLETIN Lateral Tension System The International Residential Code (IRC) requires that decks be designed to withstand both vertical and lateral loads. Until recently, the existing
More informationAFCO-Rail Post INSTALLATION INSTRUCTIONS AFCO-RAIL POST
AFCO-Rail Post INSTALLATION INSTRUCTIONS TOOLS REQUIRED: Drill Bits (for the appropriate fastener) Drill (with adjustable clutch, recommended) Level String Line Tape Measure Tools to install fasteners
More informationInstallation Instructions for. Before You Begin TOOLS REQUIRED
Composite Railing System STEP-BY-STEP Installation Instructions for Spectrum Composite Railing Virtually maintenance free 20-year warranty EverNew Spectrum Railing system is designed to work with a number
More informationHow to Build Good Decks..
How to Build Good Decks.. Worldwide Sleeping Company, Inc Cary, North Carolina Decking Overview.. Decking Overview.. more Decking Joist.... Joist Hanger Ledger Lag Screw House Wall Decking House Floor
More information10x12 FOUNDATION GUIDE 10x12 TRICO AND FLORA SHEDS
10x12 FOUNDATION GUIDE 10x12 TRICO AND FLORA SHEDS 10x12 WOOD SKID FLOOR FLOOR SYSTEM FOR 10x12 TRICO AND FLORA SHEDS RAW MATERIALS LIST: 2 (9) FLOOR FRAMING AND SHEATHING: 1) BAND BOARD 2 x 6 x 12 PRESSURE
More information1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.
PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards. B. See Division 5 Section "Pipe and Tube Railings"
More information4Post Server Rack-111 Assembly For Floor Anchored Models
4Post Server Rack-111 Assembly For Floor Anchored Models Patent(s) Pending Installation Instructions Kit P/N: 111-1720 111-1721 111-1722 111-1723 111-1724 111-1767 111-2325 111-2257 111-2408 111-2457 111-2458
More informationMPA-9000 Universal Ceiling Projector Mount Kit
I N S T R U C T I O N M A N U A L Universal Ceiling Projector Mount Kit The Universal Ceiling Projector Mount provides a unique, simplified method of ceiling mounting your inverted projector. This low
More informationOcean View. Deck Planner Software Report for Simpson Template. 1 All rights reserved copyright 2017 DIY Technologies
Ocean View Deck Planner Software Report for Simpson Template 1 Your Planned Deck Design Plan View w/ Decking Removed 25' 25' 9' 17' 8" 21' 11" 5' 8' 4' 3" 4' 3" 10' 9" 5' 1/2" 4' 11 1/2" 25' Plan View
More informationFortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.
Installation Instructions for Fortress Vertical Cable Panel System with Brackets and Fe Posts It is the responsibility of the installer to meet all code and safety requirements, and to obtain all required
More informationGENERAL INSTALLATION GUIDE: WARRANTY: PRODUCT INFORMATION T F
GENERAL INSTALLATION GUIDE: Unless otherwise indicated, all Seven Oaks M.U. Architectural Products materials are to be used for decorative purposes only. All products must be installed using ample amount
More informationCOMPACT DECK. Compact Deck SOUTHERN FOREST PRODUCTS ASSOCIATION SOUTHEASTERN LUMBER MANUFACTURERS ASSOCIATION
COMPACT DECK SOUTHERN FOREST PRODUCTS ASSOCIATION SOUTHEASTERN LUMBER MANUFACTURERS ASSOCIATION P.O. BOX 641700 KENNER, LA 70064-1700 (504) 443-4464 FAX (504) 443-6612 www.southernpine.com Compact Deck
More informationMaryland Building Officials Association Typical Deck Details
Maryland Building Officials Association Typical Deck Details Based on the International Residential Code The design details in this document apply to residential decks only. Framing requirements are limited
More informationFortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.
Installation Instructions for FortressCable H-Series Stair Panels with Simplified Stair Bracket SSB-05 and Fe Posts It is the responsibility of the installer to meet all code and safety requirements, and
More information3. Are component and cladding design pressures consistent with ASCE 7 for the wind speed and exposure category (ASCE 7 Fig. 6-3)?
Mobile County Public Works Residential Plan Reviewers Checklist For Structural Requirements of Wood Framed Residences Recommendation: Permit as Noted Revise Plans and Resubmit MCPW Ref. No. Design Criteria:
More informationCAB END BEDTRAX (SIDE VIEW)
Supplied Hardware: (8-14) 1/4-20 Allen head bolts, (12-18) UHMW mount blocks, (4) D-ring tie downs Tools Needed: Allen head wrench GET TO IT. INSTALLATION INSTRUCTIONS STEP 1. INSERT (2) MOUNT BLOCKS INTO
More informationPAINT & MISC. Notes. Table of Contents. Front Handrail Posts Front Handrails Closet Shelving Exterior Deck...
118 PAINT & MISC. Table of Contents Front Handrail Posts... 119 Front Handrails... 122 Closet Shelving... 125 Exterior Deck... 127 Look for painter s tape on the hammer drill for where to set the depth.
More informationALUMINUM POLE VAULT STANDARDS SPECIFICATIONS
SPECIFICATIONS Specifications: All aluminum construction for superior corrosion resistance. Dual height scales provide English and Metric measurements ranging from 7' to 8'. Wide stance base for improved
More informationAl Keller s Inexpensive Backyard Greenhouse Plans
Al Keller s Inexpensive Backyard Greenhouse Plans There are many ways to construct low cost greenhouses for your property. This is just one man s design, using easily obtainable and fairly inexpensive
More informationLeveling Foot RB210. Leg Extender RLT66
Landing for Right & Left Turn R342 ITEMS # 0254049, 0254061, 0254072, 0254076, 0016567, 0254099, 0254110, 0054116, 0254117, 0254126, 0254140, 0254150, 0254156 CUSTOM ACCESS RAMP SYSTEM MODELS # R100, R242,
More information11 6 Round Building Assembly Instructions
11 6 Round Building Assembly Instructions 11 6 Round Building Hardware List 1. Pro Rib Brite White 36 Wide X 68 Long (Siding Steel) 11 2. Top Wall Wheel Ring 3 3. Base Ring 3 4. 1 ½ X 68 Aluminum Tubes
More informationBARBARMS. IMPORT 2x1 5/8x45 degrees 2 3/8x1 5/8x45 degrees
BARBARMS IMPORT 2x1 5/8x45 degrees 2 3/8x1 5/8x45 degrees DOMESTIC Senior H Beam 1 5/8x1 5/8x45degrees Arm S-Slot 2x1 5/8x45 degrees Arm S-Slot 2 3/8x 1 5/8 45 degree Arm S-Slot 1 5/8x1 5/8 Vertical Arm
More informationBIKE FILE (301)
B IK E F I L E High Efficiency The Bike File is our most space efficient u-lock compatible product. Sturdy sliding hangers allow nine bikes to be securely stored in an eight-foot section while allowing
More informationinstallation care & maintenance instructions lifecycledecking.com 25-year limited residential warranty 20-year limited commercial warranty
installation care & maintenance instructions lifecycledecking.com 25-year limited residential warranty 20-year limited commercial warranty Installation Instructions As with any building project, use proper
More informationM4 Hex Nut [ ] M4 T-Nut 20 [20-044] Appx. 1. 3mm. 20 Series profiles (1 per hole) (1 per hole) Ordering Information
Handles & Light Duty PA 20 1 Assembly of Hinge M4x8 FHCS [24-208-4] M4 T-Nut 20 [20-044] M4 Hex Nut [24-706-4] 60 300-0 PA 20 on panel 2 Hinge positions 3-4 Clearance dimensions 5 Range of swing FOR M4
More informationFASTENERS BUILDING DEPARTMENT
FASTENERS BUILDING DEPARTMENT 952-446-1660 WWW.CITYOFMINNETRISTA.COM This handout is intended only as a guide and is based in part on the 2015 Minnesota Residential Code, Minnetrista City ordinances, and
More informationPREPARATION & TOOL CHECKLIST
INSTRUCTION MANUAL RAILING PRODUCTS BEGIN TO AGE AS SOON AS THEY ARE EXPOSED TO NATURE. BUILDINGS EXPERIENCE AGING FACTORS DIFFERENTLY, SO IT IS DIFFICULT TO PREDICT HOW LONG RAILING PRODUCTS WILL LAST.
More informationATI Evaluation Service A Division of Architectural Testing Certification Services
ATI Evaluation Service A Division of Architectural Testing Certification Services Subject to Renewal: 11/15/2011 Issued: 11/15/2010 Visit for current status Page 1 of 16 Maine Ornamental LLC 933 U.S. Route
More informationOffering a full range of anchoring and tie down systems including:
Offering a full range of anchoring and tie down systems including: BE SURE TO CONSULT LOCAL REGULATORS FOR CODE QUESTIONS AND THE MANUFACTURERS INSTALLATION MANUAL FOR PROPER MATERIALS. Anchors Pan Systems
More informationALUMINUM PIPE GUIDERAIL 01/01/
NOTES PIPE RAILING & POSTS: Structural Tube, Pipe and Bar shall be in accordance with ASTM B22 or ASTM B429, Alloy 606-T6. End Rail 90 bends and corner bends with maximum 4-0" post spacing, may be Alloy
More informationBID TABULATION SHEET
Title: Guide Rail & Guide Rail Parts Opening Date: Thursday, January 5, 2017 @ 2:00 pm Contract #: CC-0039-17 Total Bids Received: Signed Proposal Stock Disclose BID TABULATION SHEET Non- Collusion Affirm
More informationATI Evaluation Service A Division of Architectural Testing Certification Services Code Compliance Research Report
ATI Evaluation Service A Division of Architectural Testing Certification Services Subject to Renewal: 04/15/2016 Issued: 06/24/2014 Visit www.ati-es.com for current Revised: 09/24/2014 Page 1 of 21 Maine
More information(TOLL FREE); 7am 7pm Pacific Time, Monday-Saturday ASSEMBLY INSTRUCTIONS FOR THE ATTACHED GARDEN PERGOLA WITH LEDGER BOARD
866.332.2403 (TOLL FREE); 7am 7pm Pacific Time, Monday-Saturday ASSEMBLY INSTRUCTIONS FOR THE ATTACHED GARDEN PERGOLA WITH LEDGER BOARD Note will vary Description Posts Single Supports Supports with In-Between
More informationTYPICAL PATIO COVERS. OWNER: ADDRESS: PHONE:
City of Aliso Viejo Building Division 12 Journey, Suite 100 Aliso Viejo, CA 92656 (949)425-2540 Fax (949)425-3899 www.cityofalisoviejo.com TYPICAL PATIO COVERS 111 I. GENERAL Patio covers are one-story,
More informationTop Closure Kit Accessory for Music Library System
Assembly Instructions Top Closure Kit Accessory for Music Library System Contents Required Tools.....................................2 Installation Requirements............................2 Fasteners -
More informationRELINER INSIDE DROP SYSTEM SPECIFICATIONS
1. PRODUCT NAME RELINER INSIDE DROP SYSTEM U.S. Patent 6074130 Canadian Patent # 2269565 All RELINER Products are proudly made in the U.S.A. 2. MANUFACTURER RELINER /Duran Inc. 53 Mount Archer Rd. Lyme
More informationPARTS INCLUDED IN FIXED STAIR CABLE RAIL KIT:
175 SERIES FIXED STAIR CABLE RAIL - INSTALLATION INSTRUCTIONS PARTS INCLUDED IN FIXED STAIR CABLE RAIL KIT: FIXED STAIR TOP RAIL (1) A FIXED STAIR BOTTOM RAIL (1) B D UPPER SADDLE BRACKET (1) C BRACKET
More informationAUXILIARY FRAMING AND ACCESSORIES
CUSTOM CABINETS & RACKS STRUT AND ACCESSO- RIES JUNCTION KITS ANGLE AND BRACE KITS SPLICE KITS BRACE KITS INSTALLATION KITS WALL ANGLE KITS RUBBER END CAPS SUPPORT INSTALLATION AND SUPPORT KITS STANCHION
More informationSTEEL PIPE GUIDERAIL 01/01/
NOTES PIPE RAILING & POSTS: Pipe Rails and s shall be in accordance with ASTM A5 Grade B for standard weight pipe and ASTM A500 Grade B, C or D or ASTM A50 for structural tube. Bars for handrail supports
More informationEdgerail Aluminum Bridge Railing System Specification & Installation Instructions
Edgerail System Specification & Installation Instructions Hill & Smith, Inc 1000 Buckeye Park Road Columbus, Ohio 43207 Tel: 614-340-6294 Fax: 614-340-6296 www.hillandsmith.com Section A System Specification
More informationBaby Grande or Grande Crank Shade with Cables and Housing Installation Instructions
Baby Grande or Grande Crank Shade with Cables and Housing Installation Instructions Tools Needed Drill 3/8 Metal Drill Bit Screwdriver (Flat & Phillips) Measuring Tape Pencil 4 Level Plumb Line ¼ Masonry
More informationPRACTICAL ENGINEERING. Strong Rail-Post Connections for Wooden Decks
PRACTICAL ENGINEERING Strong Rail-Post Connections for Wooden Decks by Joseph Loferski and Frank Woeste, P.E., with Dustin Albright and Ricky Caudill Researchers at Virginia Tech applied measured loads
More information