Installation guide. ROCKFON VertiQ. ROCKFON System T, ROCKFON System HAT. Impact-resistant and high impact-resistant acoustic wall panel solutions
|
|
- Lisa Dean
- 5 years ago
- Views:
Transcription
1 Installation guide ROCKFON ROCKFON System T, ROCKFON System HAT Impact-resistant and high impact-resistant acoustic panel solutions
2 ROCKFON System T, ROCKFON System HATT Contents System selection...3 Edges and sizes...3 ROCKFON System T (impact-resistant) Components...4 Mounting diagrams...4 Single-panel height solutions...5 Multiple-panel height solutions Perimeter trim T fixing brackets and supporting brackets Wall panels and horizontal intermediate profiles Vertical intermediate profiles...11 ROCKFON System HAT (high impact-resistant) Components...12 Mounting diagrams Perimeter trim Wall panels and horizontal intermediate profiles Vertical intermediate profiles...15 For information about storage, handling, service integration and special requirements, this system installation guide should be read and used in conjunction with ROCKFON General Guidelines for Installation. ROCKFON System T ROCKFON System HAT Installation shows 1200 x 1200mm layout at top and 2700 x 1200mm at bottom. 2
3 ROCKFON System T, ROCKFON System HATT System selection ROCKFON s are tough and durable in their own right, however overall system impact resistance will be determined by the type of installation system chosen. Contact ROCKFON for further information and advice about impact resistance. We recommend the use of clean nitrile or PU coated gloves when installing ROCKFON tiles in order to avoid fingerprint marking on the surface. For an optimum work environment, we recommend installers always observe common work practices and follow installation advice as shown on our packaging. ROCKFON System T: Impact-resistant solution, 40 mm thick ROCKFON VertiQ A24 panels can be installed using J channel perimeter trims and standard 38 mm deep T24 tees as intermediate profiles fastened directly to the using T fixing brackets and supporting brackets (when needed). ROCKFON System HAT: High impact-resistant solution, according to DIN for panels or Class 1A according to EN annex D for ceilings In order to achieve high impact resistance against, for example, balls in sports halls, 40 mm thick ROCKFON VertiQ A HAT panels should be installed using 1 mm thick steel ROCKFON System HAT profiles fixed directly to the. Important Use mounting screws/methods appropriate for the material. Ensure that the is smooth and level. Any leveling correction must be done before any installation begins. For high impact-resistant solutions using ROCKFON System HAT, ROCKFON VertiQ panels must be mounted directly on the without any gap behind them. Edges and sizes ROCKFON VertiQ A24 ROCKFON System T ROCKFON VertiQ A HAT ROCKFON System HAT ROCKFON VertiQ edges and panel dimensions 40 mm M = Module size A24 = M minus 8 mm (M-8 mm) A HAT = M minus 28 mm () ROCKFON s Edge Module size* (mm) Exact size* (mm) A x 1200 x x 1192 x 40 A x 1200 x x 1192 x 40 A HAT 1200 x 1200 x x 1172 x 40 A HAT 2700 x 1200 x x 1172 x 40 * For other dimensions, please contact ROCKFON. 3
4 ROCKFON System T Rear view of installation seen from inside the. 40 mm deep J channel perimeter trims and 38 mm deep T24 tees as intermediate vertical and horizontal profiles are used for ROCKFON System T. J channel perimeter trims are fastened with screws, together with SMF clips where needed. For multiple-panel installations, both horizontal and vertical T24 intermediate profiles clip into place using T fixing brackets mounted directly to the. Supporting brackets are also required for multiple-height or off-floor/ base support installations. Total installation depth is 40 mm. Components Wall panels Perimeter trim Intermediate profiles T fixing bracket Supporting bracket Clip ROCKFON VertiQ A mm long 40 mm J channel, wide-side and narrow-side 3000 mm long 38 mm deep T24 tees for use with 38 mm deep T24 tees (patent pending) 15x35x50 mm SMF clip Perimeter trim, bottom for multiple-height installations resting on the floor or base support, use a M-4 mm measure between the bottom J channel perimeter trim and first horizontal T24 intermediate profiles. This is to ensure the ROCKFON VertiQ top edges are properly covered by T24 front capping. All further vertical levels will use standard M measure distance. Supporting bracket these provide required bottom support to panels within a multipleheight or off-floor/base support installation. They are mounted so the underside is 4 mm above the module axis line (which the T fixing bracket channels are centred on) so the panels come to rest upon them (see the diagram on page 6). SMF clip for use when the top J channel perimeter trim needs to be installed last, offering demountability. Mounting diagrams 400 mm 950 mm 2700 x mm 1500 mm 600 mm 950 mm 400 mm 2700 x mm 1500 mm 600 mm 400 mm 400 mm 400 mm 600 mm 1200 x x mm 600 mm 1200 mm 600 mm 2700 x mm 400 mm 400 mm 900 mm 1500 mm 600 mm 4
5 ROCKFON System T Single-panel high solutions 1. Top J channel fixed wide-side to the with SMF clip, min. 14 mm distance to the ceiling should remain. Insert the top J channel perimeter trim into the SMF clips, then lift it up 14 mm to allow the top edge of the panel to fit in. When all the panels are in place, the top J channel slides back down to cover the top edges. Vertical T24 intermediate profiles clicked into T fixing brackets should be installed before lowering the top J channel perimeter trim. 2. Top J channel fixed narrow-side to the with SMF clip, can be mounted directly under the ceiling. Insert the top J channel perimeter trim into the SMF clips, then the top edge of the ROCKFON into the top J channel perimeter trim so the bottom edge can pass over and set down into the bottom J channel perimeter trim. Vertical T24 intermediate profiles are installed as the final step using the same motion as used for the panels. top J channel min. 14 mm under the ceiling 1 M M-4 mm 2 M M-14 mm 14 mm top J channel perimeter trim fixed wide-side to the with SMF clip top J channel perimeter trim fixed narrow-side to the with SMF clip SMF clip fixed to the SMF clip fixed to the scuff-resistant base support, e.g. solid timber scuff-resistant base support, e.g. solid timber Bottom J channel perimeter trim: 1. supported by scuff-resistant base support 2. unsupported, above the floor, with supporting brackets inside 3. supported by the floor 40 mm bottom J channel perimeter trim fixed wide edge to the scuff-resistant baseboard, e.g. solid timber 40 mm bottom J channel perimeter trim fixed wide edge to the 15x35x50 mm supporting brackets inside bottom J channel fixed to the 40 mm bottom J channel perimeter trim fixed wide edge to the 5
6 ROCKFON System T Multi-panel high solutions M M M-4 mm M-8 mm M-8 mm M-8 mm 40 mm 40 mm 4 mm top J channel perimeter trim fixed wide-side to the supporting bracket fixed to the 4 mm above axis T fixing bracket fixed to the, channel centred on the axis horizontal T24 intermediate profile clicked into T Fixing bracket base J channel perimeter trim fixed wide-side to the 600 mm VertiQ 1200x supporting bracket VertiQ 2700x1200 vertical - 2 supporting brackets VertiQ 2700x1200 horizontal - 3 supporting brackets panel = M-8 mm M = 2700 mm or 1200 mm supporting bracket for 2700x1200 vertical and horizontal, align base 4 mm above axis supporting bracket for 2700x1200 vertical and horizontal, align base 4 mm above axis 400 mm 400 mm 4 mm 300 mm 300 mm 600 mm 300 mm T fixing bracket, channel centred on the axis supporting bracket for 1200x1200 and 2700x1200 horizontal, align base 4 mm above axis and at panel-width centre 6
7 ROCKFON System T 1. Perimeter trim Module (M) Module (M) Module (M-4 mm) Mark out all the axes for perimeter trims and intermediate profiles at Module (M) measures. For the bottom row of panels, use M-4 mm up from the bottom J channel perimter trim. every 400 mm within 1200 mm 1.2 Top and side perimeter trims affixed wide edge to the. every 400 mm within 1200 mm every 300 mm 1.3 Side perimeter trim affixed wide edge to the, top perimeter trim affixed narrow edge to the with SMF clip. This method allows for demounting of the top trim. support bracket at panel centre, 1200 mm and 2700 mm horizontal every 450 mm within 2700 mm 400 mm in from both left and right edges, all 2700 mm panels every 450 mm within 2700 mm Important Use mounting screws/methods appropriate for the material. Use a sharp-bladed saw to carefully achieve neat corner joints. Placing an internal support, e.g. 40 mm thick wood block, inside the perimeter trim will reduce bending / damage when cutting. Use supporting brackets to support multi-height installation panels and bottom perimeter trim not resting on the floor/base support; For off-floor installations, consideration should be given to using a scuffresistant skirting or base support between the floor and bottom perimeter trim. This will reduce the likelihood of damage from shoes, luggage, vaccuum cleaners or other floor-level risks and help avoid ball or human contact with any low-lying perimeter trim corners. 1.4 Bottom perimeter trim resting on the floor or other solid base support material. 1.5 Bottom perimeter trim floating above the floor requires the use of supporting brackets. 7
8 ROCKFON System T 2. T fixing brackets and supporting brackets T fixing brackets and supporting brackets are required to: prevent accidental removal of intermediate profiles; provide enough support for each panel separately in multiple-height installations; make a secure yet demountable installation intermediate profiles can be removed from their T fixing brackets by using a special teeremoval tool, as long as their positions are known. Remember to follow recommended guidelines for quantity and positioning of both T fixing brackets and supporting brackets. Important Creating a demountable solution depends on knowing where all the T fixing brackets are located after installation is completed. An installation diagram clearly showing the positions of all T fixing brackets should be made and archived. This will enable easy location of these components for any subsequent maintenance. Module 1200 mm 600 mm 300 mm 300 mm T fixing brackets Supporting brackets Module 1200 mm 600 mm 1200 mm 600 mm 2.1 Placement of all T fixing brackets and supporting brackets should be measured out and mounted before any panel installation begins. Doing so will greatly reduce installation time. Ensure that all brackets line up T fixing brackets channel on the module axis, supporting brackets underside 4 mm above it. Consumption guide (pieces per panel) Panel size (mm) Panel orientation 2700 x 1200 Vertical 2700 x 1200 Horizontal 1200 x 1200 Supporting brackets (off-floor/base support or multi-panel height installations only) 2: 400 mm in from both left and right edges 3: 400 mm in from both left and right edges, one at panel-centre 1: 600 mm in from both left and right edges (panel-centre) T fixing brackets, horizontal 0 if a single-panel height installation, 2 at each additional panel junction: 300 mm in from both left and right edges 0 if a single-panel height installation, 2 at each additional panel junction: 600 mm in from both left and right edges 0 if a single-panel height installation, 2 at each additional panel junction: 300 mm in from both left and right edges T fixing brackets, vertical 0 if a single-panel wide installation, 2 at each additional panel junction: 600 mm in from both top and bottom edges 0 if a single-panel wide installation, 1 at each additional panel junction: 600 mm in from both top and bottom edges (panel-centre) 0 if a single-panel wide installation, 1 at each additional panel junction: 600 mm in from both top and bottom edges (panel-centre) Installation of ROCKFON s should only be done using components supplied by ROCKFON. Components are sold separately. Failure to follow these instruction will void any warranty. 8
9 ROCKFON System T 3. Wall panels These instructions cover both single and multiple-height installations. For multiple, the terms upper and lower refer respectively to the uppermost and lowermost panels. Start installing ROCKFON VertiQ panels working inward from the outside / perimeter panels, both left and right. Ensure that all outside / perimeter panel edges are securely under their perimeter trims. As outside / perimeter panels are installed, cover their horizontal joints with 38 mm deep tees cut to exactly M-12 mm (see diagram on page 11). This secures the panel enough to continue safely working inward. 3.1 Angle an upper panel into the top J channel perimeter trim, then flat against the. Ensure there is sufficient trim overlapping the panel top, then slide it carefully into the vertical J channel perimeter trim. 3.2 The bottom of all multiple-height installation panels should rest securely on their supporting bracket(s) see diagram on page Angle a lower panel into the bottom J channel perimeter trim, then flat against the. Slide it carefully into the vertical J channel perimeter trim. 3.4 When required, remember to use supporting brackets mounted inside the bottom J channel perimeter trim. 3.5 Install any intermediate panels, working from upper to lower. They should sit securely in place via supporting bracket(s) and perimeter trim see diagram on page Cover the horizontal joints between panels by clicking T24 profiles into the T fixing brackets, then slide it carefully under the perimeter trim edge. These horizontal tees must be cut to an exact dimension of M-12 mm. 9
10 ROCKFON System T 3.7 External corner two vertical J channel perimeter trims are fastened to each other every 300 mm and from each end. The -mounted perimeter trim is fixed wide-edge to the, also every 300 mm. 3.8 Internal corner one vertical J channel perimeter trim is mounted a distance of 40 mm from the corner, wide-edge affixed to the every 300 mm. This allows a ROCKFON to slide into the corner behind it Perimeter trim finishing around a door or window should always be done with J channel perimeter trims mounted wide-edge to the, affixed every 300 mm and from all ends. To minimize panel waste, measure and cut carefully while ensuring adequate perimeter trim overlap Cover all remaining horizontal joints between panels by clicking T24 profiles into the T fixing brackets. Horizontal profiles should be cut to an exact dimension of M-12 mm. Ensure the outter ends of the horizontal tees are covered by the perimeter trims. Important The standard locking connectors at each end of a T24 profile are not needed when installing ROCKFON VertiQ A24 in ROCKFON System T. Do not include them in any measurements, simply cut them off Install all remaining intermediate panels as described on page 9, working from the top downwards. During installation, cover all horizontal joints with T24 profiles by clicking them into the T fixing brackets. When the entire installation is fitted with ROCKFON s, the final step is covering all the vertical joints with long tees clicked into T fixing brackets (see next section). 10
11 ROCKFON System T 4. Vertical intermediate profiles 4.1 When the entire surface is covered with panels, cover all the vertical joints with long T24 profiles clicked into the T fixing brackets. These vertical tees must be cut to an exact length of X-12 mm, where X is the installation height. Ensure the ends of all horizontal tees are covered by the vertical tees, and that both ends of the vertical tees are sufficiently covered by the top and bottom perimeter trims. Use additional T fixing brackets to connect vertical profile extensions when required. 4.2 All ROCKFON VertiQ A24 panels and tees installed. Wall M -12 mm M -12 mm M -12 mm M M M M = Module 11
12 ROCKFON System HATT Rear view of installation seen from 'inside' the. 40 mm deep HAT profiles, made from 1.0 mm thick steel, are used as vertical and horizontal profiles in the ROCKFON VertiQ high impact resistant ROCKFON System HAT. 40 mm deep J channels, or alternatively the same HAT profiles, both made of 1.0 mm thick steel are used as perimeter trims. All the profiles are affixed directly to the with appropriate fixings, suitable to the material. Total installation depth is 40 mm. Components Wall panels Perimeter trim Intermediate profiles ROCKFON VertiQ HAT 2700 mm long, 1 mm thick 40 mm deep J channel, wide-side and narrow-side 2700 mm long, 1 mm thick HAT (alternative) 1148 mm and 2700 mm long, 1 mm thick HAT Mounting diagrams Wall M-12 mm M M M-12 mm 28 mm 28 mm 28 mm M = Module Wall 50 mm 50 mm 50 mm 50 mm 50 mm 28 mm 28 mm 28 mm 1200 x x x x x
13 ROCKFON System HATT 5. Perimeter trim M (using HAT top trim) M-12 (using J channel top trim) Module (M) M (using HAT bottom trim) M-12 (using J channel bottom trim) 5.1 Mark out all the axes for perimeter trims and intermediate profiles. Important Use mounting screws/methods appropriate for the material. Use a sharp-bladed saw to carefully achieve neat corner joints. Placing an internal support, e.g. 40 mm thick wood block, inside the perimeter trim will reduce bending / damage when cutting. 5.2 Top and side perimeter trims, wide edge to the. For off-floor installations, consideration should be given to using a scuff-resistant skirting or base support between the floor and bottom perimeter trim. This will reduce the likelihood of damage from shoes, luggage, vacuum cleaners or other floor-level risks and help avoid ball or human contact with any low-lying perimeter trim corners. 5.3 Bottom perimeter trim resting on the floor or other solid base support material. 13
14 ROCKFON System HATT 6. Wall panels and horizontal intermediate profiles 6.1 Start installing ROCKFON VertiQ panels working inward from the outside / perimeter panels, both left and right, bottom panels first. Ensure that all outside / perimeter panel edges are securely under their perimeter trims. 6.2 For multiple-height installations, place the next panel above and cover the horizontal joint(s) between panels with a 40 mm HAT profile the exact length of M-52 mm (see diagram on page 15), affixed at panel centre (figure 6.4). Ensure that the panel edges are covered by perimeter trims (J or HAT) and intermediate HAT profiles. 6.3 All outside / perimeter panels installed with horizontal HAT profiles. 52 mm 6.4 Install all the remaining panels and horizontal HAT profiles, working toward the middle. Cover all the horizontal joints with HAT profiles centred on the panel width leaving a 52 mm gap between them for the vertical HAT profile. 14
15 ROCKFON System HATT 7. Vertical intermediate profiles Wall M = Module 50 mm vertical HAT M M-52 mm horizontal HAT 50 mm vertical HAT 7.1 All ROCKFON s and HAT profiles installed. The vertical HAT profile edges should meet cleanly against the horizontal HAT profile edges, not overlap them. 15
16 We believe our acoustic stone wool and metal solutions for ceilings and s are a fast and simple way to create beautiful, comfortable and safe spaces. Easy to install and durable, they protect people from noise and the spread of fire. They are our way of making a constructive contribution towards a sustainable future. Create and Protect is what drives us. It means putting people first, sharing success and maintaining trust. It s our rock-solid promise to you. At ROCKFON, Create and Protect is what we do - and it s inspired by you All colour codes mentioned are based on the NCS - Natural Colour System property of and used on licence from NCS Colour AB, Stockholm Subject to alterations in range and product technology without prior notice. ROCKFON accepts no responsibility for printing errors. ROCKFON A trading division of ROCKWOOL Limited Hammersmith Grove, London, W6 7HA Tel: +44 (0) Fax: +44 (0)
ROCKFON System Olympia Plus
Installation guide ROCKFON System Olympia Plus Sports Ceiling Impact Class 1A Suspension system Exposed impact-resistant 50mm grid system 11 6 9 8 12 7 11 4 1 5 3B 3A 10 2 1. 50 mm main runner CMC 3050
More informationRockfon System OlympiaPlus A Impact 1A
System description Rockfon System OlympiaPlus A Impact 1A Ceiling systems for special applications Impact resistance SYSTE GRP WAR YEARS IT LIM ED E very single tile is demountable for easy and fast access
More informationOlympia Plus Sports Ceiling Impact Class 1A
Olympia Plus Sports Ceiling Impact Class 1A Suspension system Exposed impact-resistant 50mm grid system 11 6 9 8 12 7 11 4 1 5 3B 3A 10 2 1. 50 mm main runner CMC 3050 2. 50 mm cross tee CMC 3054 3. Hold-down
More informationInstallation Guide. Rockfon Eclipse
Installation Guide Rockfon Eclipse GENERAL INFORMATION System description: Rockfon Eclipse is a frameless acoustic island available in square, rectangular and other geometric shapes. The square and rectangular
More informationCI/SfB. October RockLink Integra. Installation system
CI/SfB (35) Xh2 October 2008 RockLink Integra Installation system RockLink Integra 1 6 Rockfon tiles with the E15 straight edge detail are suitable for installation using this system. 6 2 6 The following
More informationMETALWORKS Concealed. Installation Instructions
METALWORKS Concealed Installation Instructions 1. GENERAL 1.1 Product Description MetalWorks Concealed ceilings consist of perforated and unperforated panels that are downward accessible, and are designed
More informationCI/SfB. January Rockfon Color-all
CI/SfB (35) Sm1 January 2015 106 Rockfon Color-all 34 exclusive colours plus a bespoke colour service to create imaginative acoustic ceiling solutions that inspire and enhance your interior design scheme.
More informationAXIOM Classic Trim. Assembly and Installation Instructions
AXIOM Classic Trim Assembly and Installation Instructions 1. GENERAL 1.1 Description Axiom Classic Trim is a perimeter trim system designed for use with a variety of Armstrong suspension systems. Classic
More informationAXIOM Classic Trim Installation Instructions
CEILING SYSTEMS AXIOM Classic Trim Installation Instructions 1 GENERAL 1.1 Description Axiom is a perimeter trim system designed for use with most of Armstrong s suspension systems. It is available through
More informationInstallation Manual for Metal Emperor Lockers
P a g e 1 Table of Contents Page General Notes and Tools Required 2-3 Assemble Shelves with Coat Hooks/Coat Rods 4 Fastening Chart 5 Knock Down Locker Assembly (Banks of Three) 6-12 Appendix A: Dress End
More informationInstallation Manual. Solid Plastic Toilet Partitions. IN CANADA & AREAS OTHER THAN U.S.A.: IN THE U.S.A.:
Installation Manual Solid Plastic Toilet Partitions Toilet Partitions & Lockers IN THE U.S.A.: Hadrian Inc., 7420 Clover Avenue, Mentor, OH 44060 Telephone: 440-942-9118 Fax: 440-942-9618 U.S. toll free
More informationTrim (Aluminum Substrate)
CEILING SYSTEMS Between us, ideas become reality Trim (Aluminum Substrate) GENERAL Description WoodWorks Trim (aluminum substrate) is a unique system designed for use with Tegular, Vector, Linear and Channeled
More informationARMSTRONG METALWORKS BAFFLES Installation Guide
ARMSTRONG METALWORKS S Installation Guide ARMSTRONG METALWORKS S Installation Guide Product Description The Armstrong METALWORKS Baffles ceiling system consists of a range of extruded aluminium Baffle
More informationSINGLE TRACK BYPASS (patent pending) barn door hardware
SINGLE TRACK BYPASS (patent pending) barn door hardware Installation Manual What is included in your kit: Part number Part name Quantity 1 Inner door hanger 2 2 Outer door hanger 2 3 5/16 x 1.5 lag bolts
More informationMethod of Build 1. Fire. Sound
Method of Build 1 General Viso Fire & Acoustic in the solid form differs from most other systems as it can be erected using 12.5mm & 15.0mm boards within the same Aluminium framework. Also hidden fix board
More informationAssembly Instructions
Unite Panel System Hinge Door July 2016 #12 x / slotted hex washer head bolt Figure 1 threshold bracket frame Detail F threshold bracket threshold bracket (installed) #12 x / slotted hex washer head bolt
More informationAXIOM Classic Trim. Assembly and Installation Instructions 1. GENERAL
AXIOM Classic Trim Assembly and Installation Instructions 1. GENERAL 1.1 Description Axiom Classic Trim is a perimeter trim system designed for use with a variety of Armstrong suspension systems. Classic
More informationcompile system INSTALLATION GUIDE Updated January 2019
INSTALLATION GUIDE Updated January 09 compile system Table of Contents Panels 0 Quick Connect Clips 0 Lock Clips 0 Panel Trims 0 Privacy Glass 0 Post Base Covers 04 Electrical 04 Power Distribution Harness
More informationInstallation Guide. Rockfon Eclipse
Installation Guide Rockfon Eclipse GENERAL INFORMATION System description: Rockfon Eclipse is a frameless acoustic island made from a 40 mm bevel edged stone wool panel. The visible side is covered with
More informationXenon 05 Installation Instructions & Parts List
Xenon 05 Installation Instructions & Parts List Illustration Xenon 05, H1 Handle Left Hand: Open Out 26/05/2016 Revision 2.1 Page 1 of 19 IMPORTANT This shower screen / enclosure must be installed by suitably
More information15mm Solid European Droploc Oak Fitting Guide & Warranty Information
15mm Solid European Droploc Oak & Warranty Information Introduction Congratulations on your purchase of your brand new Timba Floor 15mm European Solid Oak Flooring. Prior to installation please examine
More informationBionic 4 PERIMETER, CONTINUOUS RUN X3, X7
I NSTALLAT ION INSTRUC TIONS 6 3 /4 6 3 /4 3¾ 5 1 /2 For LP installs, ceiling opening is equal to row length + 3 /4 8 1 /2 4 3 /32 5 1 /4 Flush X7 Shown PARTS SHIPPED SEPARATELY 4 3 /32 5 1 /4 3" Regressed
More informationWall Panel Systems, Inc.
Wall Panel Systems, Inc. 421 Business Center Court, Redlands, CA 92373 Support@wallpanelsystems.net www.wallpanelsystems.net TEL: (909) 307 8888 FAX: (909) 307 8887 Toll: (877) 333 4WPS Before you begin
More informationInstallation instructions for co-extruded louver-board profiles
Installation instructions for co-extruded louver-board profiles www.silvadec.com / info@silvadec.com / tel.:+33 (0)2.97.45.09.00 TO BE READ CAREFULLY BEFORE INSTALLATION Before starting installation on
More informationEmagiKit. Privacy Pod Plus. Quiet. Easy. Affordable. INSTRUCTIONS ASSEMBLY
EmagiKit Privacy Pod Plus Quiet. Easy. Affordable. INSTRUCTIONS ASSEMBLY DIMENSIONS AND COMPONENTS 47 47 Ceiling Unit 2-B 2-L 2-R Glass Door Corner Trim Door Handle 90 Adjustable Height Work Surface 1-B
More informationMETALWORKS TARTAN PANELS General Installation Instructions
CEILING SYSTEMS METALWORKS TARTAN PANELS General Installation Instructions 1. GENERAL 1.1. Product Description MetalWorks Tartan system is a combination of metal ceiling panels available in a range of
More informationDubnium 11 Installation Instructions & Parts List
Dubnium 11 Installation Instructions & Parts List Illustration Dubnium, H1 Handle Right Hand: Open Out Page 1 of 25 IMPORTANT This shower screen / enclosure must be installed by suitably qualified individuals.
More informationSLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE
Set A Set B PFD30 Fire Door Kit FITTING INSTRUCTIONS For use with 44mm thick doors only For Single and Double doors IF INSTALLING A TOUCH LATCH, PLEASE READ THE CORRESPONDING FITTING INSTRUCTIONS FIRST
More informationVideo Wall Installation Instructions 2W X 3H, 3W X 3H
Video Wall Installation Instructions 2W X 3H, 3W X 3H www.microndisplaysolutions.com Table of Contents Important Safety Instructions... 3 Configuration... 4 Package Contents, included and optional items...
More informationTrunking Guide. Colour List... W White M Magnolia B Black. shape & size (wxh) colours available
Trunking Guide Colour List... W White M Magnolia B Black A Aluminium O Oak Effect R Red P Premium Wood (stainable 22x22 only) F1 Light Oak Effect (22x22 only) illustrations not to scale shape & size (wxh)
More informationGallium 03 Installation Instructions & Parts List
Gallium 03 Installation Instructions & Parts List Illustration Gallium 03, H1 Handle Left Hand: Open Out 04/05/2016 Revision 1.1 Page 1 of 19 IMPORTANT This shower screen / enclosure must be installed
More informationmethod of build Komfire-75 partitioning system 75mm Steel Stud & Plasterboard Partitioning System with Square Aluminium Cover Trims KOMFORT
821 811 342 821 835 853 863 840 12.5mm Plasterboard 837 75mm Steel Stud & Plasterboard Partitioning System with Square Aluminium Cover Trims Note: For clarity the cavity infill has not been shown 854 342
More informationinstallation instructions WC Frame 1180mm with Dual Flush Cistern
installation instructions WC Frame 1180mm with Dual Flush Cistern (C,D,E) K F/G N L M 12 13 14 16 1 2 11 A 5 6 Q O Y 3 C 10 E D B P,Z,AA R T V S 4 U 2 No. Part no. Description Quantity A WC Frame with
More informationSeries 1500 Aluminum Door Canopy
Series 500 Aluminum Door Canopy with Sidewings It is our recommendation that you read instructions carefully prior to assembly and installation. Series 500 with Sidewings mounting bar (A) top trim (B)
More informationGREENHOUSE 6'x8' ASSEMBLY INSTRUCTIONS. (Internal Dimensions) Overall Dimensions (Approx.) L 193 W 200 H cms 97.5" L 76" W 78.
ASSEMBLY INSTRUCTIONS GREENHOUSE 'x8' (Internal Dimensions) Overall Dimensions (Approx.) 7. L 9 W 00 H cms 97." L 7" W 78.8" H 0 IMPORTANT You must read these instructions carefully before you start to
More informationCOMPONENTS OF THE CLICKFAST FASCIA AND GUTTER SYSTEM 5: INTERNAL MITRE
INTRODUCING THE CLICKFAST FASCIA AND GUTTER SYSTEM The Clickfast Fascia and Gutter System was originally designed by Stratco and has proven to be the most successful fascia and gutter system in Australia
More informationGrand Garden Chalet 6X3 Assembly Manual
Revision #8 November 1, 2009 Grand Garden Chalet 6X3 Assembly Manual Thank you for purchasing a Grand Garden Chalet. Please take the time to identify all the parts prior to assembly. Please use Safety
More informationSabre Series 2 Inspired Design Precision Engineering
Sabre Series 2 Inspired Design Precision Engineering USER INSTRUCTIONS Thank you for choosing the Keencut Sabre Series 2. Every effort has been made to bring you a precision engineered product with the
More informationIF INSTALLING ANY OF THE PORTMAN SELF CLOSING SYSTEMS, PLEASE READ THE CORRESPONDING FITTING INSTRUCTIONS SUPPLIED WITH THE CLOSING SYSTEM FIRST
Set A Set B PFD60 Fire Door Kit FITTING INSTRUCTIONS IF INSTALLING ANY OF THE PORTMAN SELF CLOSING SYSTEMS, PLEASE READ THE CORRESPONDING FITTING INSTRUCTIONS SUPPLIED WITH THE CLOSING SYSTEM FIRST SUGGESTED
More informationVanity Installation Instructions
Vanity Installation Instructions Segments of these instructions will relate to your vanity. Please read these instructions thoroughly and ensure the appropriate instructions are used during the installation
More informationConstable Oak Extension Dining Table
Constable Oak Extension Dining Table Assembly Instructions - Please keep for future reference 176/0325 Dimensions Width - 160/ 200cm Depth - 90cm Height - 75cm Important - Please read these instructions
More informationSTORAGE & SHELVING SYSTEM - INSTALLATION GUIDE
STORAGE & SHELVING SYSTEM - INSTALLATION GUIDE If you have ordered storage drawers, shelving, hanging rails or shoe racks this guide will help you install your storage and shelving system, together with
More informationCable Cover Guide. Color List... W White B Black P Premium Wood (stainable Floor Trim only) shape & size (wxh) colors available
Cable Cover Guide Color List... W White B Black P Premium Wood (stainable Floor Trim only) illustrations not to scale Maxi TV Drop Mini Micro Floor Trim shape & size (wxh) colors available 2⅜ x 13/16 2
More informationrondo exangle drywall finishing sections
rondo exangle drywall finishing sections SUMMARY The EXANGLE range of building board finishing profiles are designed to give plasterers a clean, defined edge on straight or curved details for internal
More informationYOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces User s Manual
YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces User s Manual [USA Fireplace Models [THIS ISTALLATION MANUAL INCLUDES ASSEMBLY INSTRUCTIONS FOR THESE MODELS: STAND ALONE 7565 CURVED TUNNEL DOUBLE
More informationLF Series Assembly Instructions
LF Series Assembly Instructions 1998760 Revision A-10 Complete Series Master Packet 2010 Kimball International, Inc. T 800.482.1818 F 812.482.8300 Footprint Storage and Metal Filing Systems Assembly Instructions
More informationDisplay Shelving Installation Instructions
Display Shelving Installation Instructions Top Rail (R-T) Back (BE) (R-C) Splicer Rail (R-S) 78 H to 120 H only Uprite (U) Uprite End Trim (UET) Shelf Back (BE) Base End Trim (BET) (R-C) 96 H to 120 H
More informationINTRODUCTION Tools Required Laminate Washroom Products... 4 DUCT PANELS Fixing the Frame: Fixing the Shadow Panels...
Contents INTRODUCTION... 2 Tools Required... 3 Laminate Washroom Products... 4 DUCT PANELS... 4 Fixing the Frame:... 5 Fixing the Shadow Panels... 9 Fitting the Duct Panels:... 10 WASHSTATIONS... 15 Fixing
More informationInstallation Manual 0318
Installation Manual 0318 DOUBLE 7 CEDAR SHINGLE INSTALLATION GUIDE General Information CAUTION: REMEMBER THAT POLYMER UNDERGOES EXPANSION / CONTRACTION DUE TO VARIATIONS IN TEMPERATURE. THE FOLLOWING INSTRUCTIONS
More informationAL13 v-line general installation guide
01 TM AL13 v-line general installation guide Vol 1 Version 1 pantented product TM AL13 architectural system www.al13.com CLAD THE WORLD TM How to Install v-line 01 TM AL13 architectural system SHEATHING
More informationCurium 19H Installation Instructions & Parts List
Curium 19H Installation Instructions & Parts List Illustration Curium 19H Right Hand Page 1 of 15 01/07/2016 Revision 2.1 IMPORTANT This shower screen / enclosure must be installed by suitably qualified
More informationDUALCASE VERSATILE ALUMINIUM SIGN SYSTEM
VERSATILE ALUMINIUM SIGN SYSTEM Universal Components Ltd. May 2007 Introduction Nothing beats DualCase for speed of fabrication, aesthetic appearance and easy maintenance. With the minium of components
More informationStep-by-step Installation Guide
Product: Resco Series 5000 Product Code: S-5000R Installation Guide Return version. May 2014 Step-by-step Installation Guide RETURN VERSION (Only 1 side wall) May 2014 IMPORTANT SAFE PANEL HANDLING INSTRUCTIONS
More informationInstallation Instructions
Installation Instructions Bespoke Glass Design In A Box Typical Installation Guidance Installation Instructions Important Information Please read these instructions carefully before starting installation
More information8x12 SpaceMaker Garden Shed Assembly Manual
8x12 SpaceMaker Garden Shed Assembly Manual Version #6 Revised June / 2007 Thank you for purchasing a 8x12 SpaceMaker Garden Shed. Please take the time to identify all the parts prior to assembly. Safety
More informationXL-GC03 Sliding Door Lock Installation Manual PAT XL-GC06 Sliding Door Hanger Installation Manual XL-GC08 Sliding Door Lock Guide Installation Manual
XL-GC0 Sliding Door Lock Installation Manual PAT XL-GC0 Sliding Door Hanger Installation Manual XL-GC0 Sliding Door Lock Guide Installation Manual Read all instructions carefully before installation. Before
More information6X3 Patio Garden Shed Assembly Manual
Thank you for purchasing a 6x3 Patio Garden Shed. Please take the time to identify all the parts prior to assembly. Revision #4 July 6th, 2016 6X3 Patio Garden Shed Assembly Manual Please use Safety Eyewear
More informationTaurean Sectional Garage Door INSTALLATION INSTRUCTIONS
BEFORE YOU BEGIN MAKE SURE THESE INSTRUCTIONS ARE READ AND UNDERSTOOD COMPLETELY. THESE INSTRUCTIONS ARE INTENDED FOR PROFESSIONAL GARAGE DOOR INSTALLERS. ALL REFERENCES ARE TAKEN FROM THE INSIDE LOOKING
More informationCertainTeed INSTALLATION GUIDE SIMTEK FENCE PRODUCTS. Fence Installation Guide 3', 4' & 6' High
CertainTeed INSTALLATION GUIDE SIMTEK FENCE PRODUCTS Fence Installation Guide 3', 4' & 6' High INSTALLATION GUIDE These instructions are designed to assist both professional installers and do-it-yourselfers
More informationInstallation Instructions Door Surrounds
www.midamericaworldwide.com Installation Instructions Door Surrounds Required for Installation: Electric drill, ¼" (6mm) drill bit, saw, screws, shutter fasteners. (¼" (6mm) carbide drill bit is required
More informationFrameless Fixed Panel Slider
INSTALLATION INSTRUCTIONS Frameless Fixed Panel Slider QCI-5279 SINGLE ROLLER WITH ANTI-JUMP DOUBLE ROLLERS QCI5279 Rev Page Certified 08/09/6 Tools: To install your New Shower Enclosure, you may need
More informationAnswer Power Beam and Boundary Screen
Answer Power Beam and Boundary Screen 5/16 MAGNETIC 3/8 If you have a problem, question, or request, call your local dealer, or Steelcase Line 1 at 888.STEELCASE (888.783.3522) for immediate action by
More informationAluminum. Fence Systems
Aluminum M Fence Systems Lifetime Warranty Aluminum Fence Systems Gates & Hardware The Morgan Series Aluminum Fence System is manufactured of the highest quality aluminum and all parts of the system are
More informationCurium 19.4H Installation Instructions & Parts List
Curium 19.4H Installation Instructions & Parts List Illustration Curium 19.4H Right Hand Page 1 of 21 30/06/2016 Revision 1.0 IMPORTANT This shower screen / enclosure must be installed by suitably qualified
More informationInstallation Instructions
Installation Instructions For Models: Model Number / Description File Name 1540 Classic Series P-Lam Toilet Partitions 1540.pdf 1 INSTALLATION INSTRUCTIONS LAMINATED PLASTIC TOILET PARTITIONS 1540 Classic
More informationRadon 07 Installation Instructions & Parts List
Radon 07 Installation Instructions & Parts List Illustration Radon 07, H1 Handle Right Hand: Open Out 14/06/2016 Revision 1.1 Page 1 of 21 IMPORTANT This shower screen / enclosure must be installed by
More informationINSTALLATION INSTRUCTIONS. Level Rail With Cap: Page 2 Level Rail Without Cap: Page 8 Stair Rail: Page 12
INSTALLATION INSTRUCTIONS Level Rail With Cap: Page 2 Level Rail Without Cap: Page 8 Stair Rail: Page 12 LEVEL RAIL WITH CAP The testing was performed in accordance with procedures and methods referenced
More informationHandleless Uni t Specification
Handleless Uni t Specification QUALITY BRITISH CRAFTSMANSHIP 160 Handless Fitting Guide - Parts Index & Base Cabinet Section 1 150 325 DRAWER 870 870 870 73 73 720 720 DOOR 685 325 2 x
More informationWOODWORKS Walls. Installation Instructions WALL
WALL Systems Between us, ideas become reality WOODWORKS Walls Installation Instructions 1. GENERAL 1.1. Product Description WoodWorks walls consist of 2' x 4', 2' x 8', 2' x 9' or 2' x 10' perforated and
More informationInstallation Instructions for Vista Air Vertically Folding Walls
Installation Instructions for Vista Air Vertically Folding Walls Use these instructions in conjunction with your shop drawings to see the specifics that are particular to the model you are installing.
More informationPocket Door Kit PD1 / PD2 Installation Instructions. Kit Contents.
Pocket Door Kit PD1 / PD2 Installation Instructions Kit Contents. 1, Create Rough Opening In Stud Wall Construct rough opening ensuring all sides are square and level. Rough opening should be; Height =
More informationSLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE
Set A Set B PFD30 SG Fire Door Kit FITTING INSTRUCTIONS For use with 44mm thick doors only For Single and Double doors SUGGESTED TOOLS DRILL G-CLAMP TAPE MEASURE (Image for reference only) HACKSAW POCKET
More informationPRO-RIB FENCE PANELS INSTALLATION GUIDELINES. Virtually Maintenance Free Available in 24 Colors Custom Heights Available by the Inch
PRO-RIB FENCE PANELS INSTALLATION GUIDELINES Virtually Maintenance Free Available in 24 Colors Custom Heights Available by the Inch www.midwestmanufacturing.com Page 2 TOOLS NEEDED Measuring Tape Drill
More informationTools needed. Supplies Needed
Installation Guide Key System Components Main beam Cross tee Tools needed Chalk line Drill (cordless) ¼" drill bit Hammer Miter saw Pencil String line(s) Stud finder Tape measure ½" to 1" wood chisel Calculator
More informationINSTALLATION. For more information on this product or to order samples call or visit our website at builddirect.com.
Page 1 Page 2 Page 3 Page 4 Page 5 1. Door Assembly: Step A: Attach part #34 to part #35 with screws #65/67. Step B & C: Attach part# 34.35(36) to part #33 with two #70 screws. Step D: Insert door bottom
More informationAIR MASTER SYSTEMS INSTALLATION GUIDE TABLE OF CONTENTS
AIR MASTER SYSTEMS INSTALLATION GUIDE TABLE OF CONTENTS GENERAL INFORMATION...1 Freight Damage... 1 Repairing Paint Scratches...1 BASE CABINETS... 2 Drawer Removal and Reinstallation...2 Replacing Drawer
More informationIMPORTANT!!! ASSEMBLY ASSEMBLY INSTRUCTIONS. (Internal Dimensions)
ASSEMBLY ASSEMBLY INSTRUCTIONS (Internal Dimensions) Ent Spec Edition Ltr v-0- Overall dimensions including base: 7. L x 9 W x 0 H cms 97.5" L x 7" W x 8.7" H IMPORTANT!!! Please read these instructions
More informationS6 User s Manual USER S MANUAL ver. 1.0
S6 User s Manual SKEETER - 1U LOW PROFILE SOLUTION Table of Contents Tabletop Configuration 2 Tabletop Configuration Accessories 4 Slide Configuration 5 slide configuration accessories 7 rack Mount configuration
More informationSLIDING DOOR SYSTEM_ S34 PRODUCT LIST. System description Accessories
SLIDING DOOR SYSTEM_ S34 PRODUCT LIST System description Accessories SLIDING DOOR SYSTEM_ S34 1.0_ System description_ page 03 2.0_ Profiles_ page 04 3.0_ Profile finishes_ page 08 4.0_ Panels_ page 09
More informationINCEPTIV INSTALLATION GUIDELINES
3D WOOD WALL PANELS INCEPTIV INSTALLATION GUIDELINES We recommend you hire an experienced finish carpenter or floor installer to achieve quality results with all Duchateau Wall Coverings. The right tools
More informationInstall Instructions. SCR-48N Crash Rail. Please read these instructions thoroughly prior to beginning the SCR-48N Crash Rail installation!
Please read these instructions thoroughly prior to beginning the installation! This instruction sheet is intended to provide a specific guide to follow for the installation of this. Contained within is
More informationOWNER S MANUAL. Safety. Please read this owner s manual before use and keep it at hand for reference. Warranty
Please read this owner s manual before use and keep it at hand for reference. OWNER S MANUAL Safety Important safety instructions for using the INCRA Miter5000 Before using the INCRA Miter5000, read and
More informationE N G L I S H GARDEN SHED. Assembly Instructions. Suitable for Models WITH VARYING DEPTHS
GARDEN SHED Assembly Instructions Suitable for Models 6' Wide 8' Wide 0' Wide WITH VARYING DEPTHS GI0003 November 0 INSTALLATION ADVICE It's Not That Difficult! The construction of your shed isn't as complicated
More informationVertical Offset Base and Safety Rail System Installation Instructions
Section 5 Vertical Offset Base and Safety Rail System Installation Instructions The vertical offset base and safety rail assembly are designed to be used in residential construction for sloped or flat
More information+ - 1a. 1b. c. 1d. 1e. Runway Suspended / Surface Cont. Run Installation. 2.0mm DIL DIL Revision - M 23/11/2018 Page 1
230-240V / 50-60Hz IP20 IK00 + - 2.0mm WARNING - THIS LUMINAIRE MUST BE EARTHED This luminaire has been tested and is manufactured to comply with BS EN 60598 : specification for general requirements and
More informationTwin-Wall Double Swinging Door Kit
115021 Twin-Wall Double Swinging Kit READ THIS DOCUMENT BEFORE YOU BEGIN Thank you for purchasing this GrowSpan door kit. When properly assembled and maintained, this product will provide years of reliable
More informationINSTALLATION INSTRUCTIONS TRI-ROOF. energy for a better world
energy for a better world INSTALLATION INSTRUCTIONS TRI-ROOF The flexible roof integration system Compatible for framed module types* Simple exchange of modules Replaces existing roofing Special profiles
More informationSLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE
Set A Set B P7001 Standard Kit FITTING INSTRUCTIONS For use with 44mm thick doors only For Single and Double doors IF INSTALLING A TOUCH LATCH, PLEASE READ THE CORRESPONDING FITTING INSTRUCTIONS FIRST
More informationShower Screen and Door Kit Instructions
Shower Screen and Door Kit Instructions Step by step guide everton.com.au IMPORTANT NOTICE IMPORTANT: The glass panels used for Highrove frameless shower screens are made from Grade A Toughened Safety
More informationSeries 1100 Aluminum Door Canopy
Series 00 Aluminum Door Canopy with Support Arms It is our recommendation that you read instructions carefully prior to assembly and installation. Series 00 with Support Arms MOUNTING BAR (A) TOP TRIM
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS HIGH PRESSUE LAMINATE (HPL) TOILET PARTITIONS 1030 TrimLineSeries 1040 DesignerSeries Includes continuous hardware option.65. IMPORTANT: Storage and Handling Information on last
More informationLUX INSTALLATION GUIDE. LUX Panel V Groove Installation. Installation Guide. February
LUX Panel V Groove Installation Installation Guide February 2017 www.luxpanel.ca LUX Panel V Groove Installation LUX panel steel cladding is designed to be installed vertically, horizontally, diagonally
More informationDeauville Installation Guide
vjul16 (for Recessed Wall Profiles) DO NOT ASSEMBLE WITHOUT FULLY READING THESE INSTRUCTIONS Page 2 Thank you for purchasing this Deauville shower enclosure. Please study these instructions carefully before
More informationClopay Models 835/837 Sliding Door System Installation Guide
Clopay Models 835/837 Sliding Door System Installation Guide The aim of this instruction is to guide you through the process of construction and fitting of Sliding Doors. Due to the number of sizes available
More informationSteelChief Installation Instructions for pre-assembled panel form sheds GABLE ROOF
SteelChief Installation Instructions for pre-assembled panel form sheds GABLE ROOF Please read fully before commencing work...any queries will be promptly answered, contact theboss@steelchief.com.aui MPORTANT
More informationLIGHT FIXTURES MUST BE COMPLETELY INSTALLED PRIOR TO CEILING CONSTRUCTION
CAUTION: BEFORE BEGINNING INSTALLATION REVIEW LAYOUT DRAWINGS, AND SHIPMENT. MAKE SURE ALL LIGHT S AND MATERIALS ARE ON SITE AND READILY ACCESSIBLE. IF ANY ICON MATERIALS ARE MISSING, CONTACT ICON INTERNATIONAL
More informationOffice Installation Guidelines
UH Structures Inc. dba Ebtech Industrial 2241 Industrial Drive Connellsville, PA 15425-6181 Telephone: 724-628-6100 Fax: 1-412-774-2429 www.ebtechindustrial.com Office Installation Guidelines INTRODUCTION
More informationSLIDING DOOR SYSTEM_ S42 PRODUCT LIST. System description Accessories
SLIDING DOOR SYSTEM_ S42 PRODUCT LIST System description Accessories 1 SLIDING DOOR SYSTEM_ S42 1.0_ System description_ page 03 2.0_ Profiles_ page 04 3.0_ System description S1600 fixed panels_ page
More informationSiding Systems NOVIKSTONETM DS DRY STACK STONE INSTALLATION GUIDE
Siding Systems NOVIKSTONETM DS DRY STACK STONE GENERAL INFORMATION CAUTION: REMEMBER THAT POLYMER UNDERGOES EXPANSION/CONTRACTION DUE TO VARIATIONS IN TEMPERATURE. THE FOLLOWING INSTRUCTIONS WILL ALLOW
More informationUlltraclad Aluminium Cladding. Contents. 1.0 General Information Design Information Installation Information 7. 4.
Ulltraclad Aluminium Cladding Contents 1.0 General Information 2 2.0 Design Information 4 3.0 Installation Information 7 4.0 Maintenance 10 5.0 Health & Safety 10 1 1.0 General Information 1.1 Introduction