Presentation Outline Pipe types and Standards

Size: px
Start display at page:

Download "Presentation Outline Pipe types and Standards"

Transcription

1 Pipe Joint Assembly and Restraint Considerations Jeff Fischer Fischer, Harris and Associates Presentation Outline Pipe types and Standards Pipe Joint Assembly Joint Restraint and Thrust Blocks Products for Joint Restraint Joint Restraint Applications 1

2 Wood Pipe Circa 1900 More wood pipe. 2

3 Wood Pipe Today 3

4 UL-FM ASTM NSF EPA DIPRA UNI-BELL Manufacturer Engineer You AWWA/ANSI C110/A21.10: Ductile Iron and Gray Iron Fittings, 3 in. through 48 in. For Water and Other Liquids AWWA/ANSI C153/A21.53: Ductile Iron Compact Fittings, 3 in. through 24 in. and 54 in. through 64 in. for Water Service AWWA/ANSI C111/A21.11: Rubber-Gasket Joints for Ductile-Iron Pressure Pipe and Fittings AWWA/ANSI C104/A21.4: Cement-Mortar Lining for Ductile-Iron Pipe and Fittings for Water AWWA/ANSI C116/A21.16: Protective Fusion Bonded Epoxy Coatings for the Interior and Exterior Surfaces of Ductile-Iron and Gray-Iron Fittings for Water Supply Service AWWA/ANSI C105/A21.5: Polyethylene Encasement for Ductile- Iron Pipe Systems AWWA/ANSI C600: Installation of Ductile-Iron Water Mains and their Appurtenances 4

5 Standard Pipe Joints Ductile Iron Push On 5

6 PVC Push On Water and Sewer Standards AWWA C900 AWWA C905 AWWA C909 ASTM D2241 ASTM D3034 6

7 Installation 7

8 Bell Stress Research Analytical Model of Stresses Caused by Over-Belling PVC Pipe Steven L. Folkman, Associate Professor, Utah State University A. P. Moser, Emeritus Associate Dean and Emeritus Professor, Utah State University Thomas Fronk, Associate Professor, Utah State University Manufacturers of large diameter PVC pipe place a mark on the spigot of the pipe to indicate the proper insertion depth into the adjoining bell during installation. If proper installation procedures are followed, inserting the spigot into the bell does not create significant stresses in the pipe. Additionally, small angle changes between two joined pipes may be accommodated in the joint without inducing pipe stresses. When pipe joint failures occur, in most instances the pipe was inserted well beyond the manufacturers recommended mark. This is referred to as Over-Belled pipe. Recommended Bar Assembly 8

9 Assembly Force Joint Stacking Even this method can over-insert previously assembled joints 9

10 5/4/ :33 PM 20 10

11 Standard Pipe Joints Flanged Normally Installed Above Ground Inherently Restrained Most pipe types offer a flanged joint of some kind. Jargon confusion by many pipe- fitters Other Flanged Pipe Materials Stainless Steel PVC HDPE Industrial Applications 11

12 1866 First Cast Iron Pipe in US History 1894 First Flange Standard 1894 (steam) 1918 Flange bolt patterns standardized 1957 Introduction of Ductile Iron Pipe and Flanges AWWA ANSI Standard adopted in 1974 Latest Revision 2005 Flange Materials For Water and Wastewater Cast Iron Threaded Ductile Iron Threaded Steel/Stainless Steel - Welded HDPE-Welded 12

13 Applicable Standards AWWA C110-C115-C207 ASME American Society of Mechanical Engineers MSS (Manufacturers Standards Society) UL-FM Flanges for Water Service Pipe and Fittings Valves Meters Tapping Sleeves Hydrants? 13

14 Thickness Flange Variations Varies from product to product Varies from manufacturer to manufacturer Serrations Cast and Ductile Iron, no AWWA standard Steel and Stainless, 32 per inch 1/64 deep spiral or concentric per AWWA Facing-Raised or Flat Cast and Ductile Iron no AWWA Standard Steel and Stainless Steel no raised face per AWWA Steel Flange Layback after welding of the flange has been completed, a draft or layback of the flange face may occur as shown in Figure 2 Total draft of layback shall not exceed 1-1/2 degrees...negative draft will not be permitted. Reference: AWWA C

15 Flange Fittings configurations Flange Gaskets Full Faced Red Rubber Cloth Inserted Rubber Ring Gaskets Hybrid Gaskets Linebacker 15

16 Bolting Carbon Steel Hex Head Grade Lubricant Recommended Stainless Steel Hex Head Grade Lubricant Required Pressure Ratings and Drillings Class 125/ for temps up to 100 df Class 250/ for temps up to 100 df 16

17 Flange Adaptors and Spool Sections Pipe can be cut in the field to exact length required Avoids long lead times and unused sections of pipe Speeds installation time resulting in lower job costs FCA Application 17

18 Flange Coupling Adaptor Attached to Pipe Plain End Pipe is lowered into postion 18

19 Gap Flange Adaptor Side by Side with a Traditional Flange 19

20 Flange Adaptor Types UniFlange, EZ Flange, Quick Flange Dismantling Joint Fittings Couplings Glue On (PVC) Fuse On (HDPE) Serrated Clamp (PVC) Megaflange Restraint Considerations Reference: Smith-Blair.com 20

21 Flange Coupling Adapter (EZ-Flange/Uni-Flange TM ) Fischer, Harris & Associat es Dismantling Joints Reference: Smith-Blair.com Provide adjustability to equipment installations by combining a flange coupling adaptor and a flanged spigot into one assembly Applications include valves, pumps, meters or other flanged equipment that may need to be removed periodically Longitudinal adjustment is provided by the telescoping action of the spigot inside the flanged coupling adaptor. Restrained model available. 21

22 FCA for Poly Reference: Coupling Type Adaptor Smith Blair 912 Epoxy Coated Ductile Insulating Option Available Short laying length Anchor studs for restraint Reference: Smith-Blair.com 22

23 Mega-Flange Type Restrained Flange Adaptor Available through 48 Allowable Gap Can be used as a dismantling joint Pipe need not be cut perfectly square Deflection up to 5% Can use above or below ground Reference: EBAA Iron.com Cross Section Reference: EBAA Iron.com 23

24 For Buried Flanged Valves Tank Connections 24

25 Standard Pipe Joints Mechanical Joint Mechanical Joint Cross Section 25

26 ANSI/AWWA C600-05, Mechanical Joint Assembly 1.Clean the socket and the plain end. Lubrication and additional cleaning should be provided by brushing both the gasket and the plain end with soapy water or an approved pipe lubricant meeting the requirements of ANSI/AWWA C111/A21.11 just prior to slipping the gasket onto the plain end for joint assembly. Place the gland on the plain end with the lip extension toward the plain end, followed by the gasket with the narrow edge of the gasket toward the plain end. NOTE: In cold weather it is preferable to warm the gasket to facilitate assembly of the joint ANSI/AWWA C600-05, Joint Assembly 2. Insert the pipe into the socket and press the gasket firmly and evenly into the gasket recess. Keep the joint straight during assembly. 3. Push the gland toward the socket and center it around the pipe with the lip against the gasket. Insert bolts and hand tighten nuts. Make deflection after joint assembly but before tightening bolts. 26

27 ANSI/AWWA C600-05, Joint Assembly 4. Tighten the bolts to the normal range of bolt torque [see table] while at all times maintaining approximately the same distance between the gland and the face of the flange at all points around the socket. This can be accomplished by partially tightening the bottom bolt first, then the top bolt, next the bolts at either side, finally the remaining bolts. Repeat the process until all bolts are within the appropriate range of the torque. ANSI/AWWA C

28 Lubrication of Mechanical Joints Friction Fischer, Harris & Associat es 28

29 29

30 Joint Restraint why do we use it? Balanced Forces Unbalanced Forces 30

31 31

32 How much thrust force is generated by a Water Pipeline? 12 DIP End Cap-150 psi Pi x Radius Squared 3.14 X 36=113 Area x pressure (PSI) 113 x 150 = 17,000 pounds of force How do we resist that force? Concrete Thrust Blocks Threaded Steel Rod Mechanical Restrainers Combinations of the above Fischer, Harris & Associat es 32

33 Fischer, Harris & Associat es 60 sq. ft. Building Thrust Blocks 33

34 Thrust Block Limitations Undisturbed soil? Contractor skill? Future connections? Concrete cure time? Vertical offsets? Sand and Swamp? Fischer, Harris & Associat es Threaded Rod Limitations High Cost Materials and Labor Corrosion Concerns Friction Clamps Fischer, Harris & Associat es 34

35 Fischer, Harris & Associat es Mechanical Restrainers Locking a pipe/fitting joint(s) together with a mechanical device designed to withstand pressures higher than normally expected to insure will not pull out at typical pressure. Fischer, Harris & Associat es 35

36 Using a high quality joint restraint device will ensure That the pipe will not pull out of the fitting. Making thrust blocks optional! Fischer, Harris & Associat es If you lock together a sufficient length of pipe, in essence it becomes it s own thrust block. 36

37 Calculating Restrained Length EBAA L Fischer, Harris & Associat es Fitting Types Supported by EBAA Design Software Tees Reducers Bends Dead Ends Vertical Offsets 37

38 38

39 39

40 40

41 Retainer Glands Pipe Joint Restraint Devices for DIP Pipe Company built-ins Wedge Action Restrainers Bell Joint Restraints Fischer, Harris & Associat es Retainer Glands Inexpensive Minimum pipe class required by some MFG Drills small hole in pipe Rigid joint will not accommodate pipe movement Low pressure rating on large diameters Cumbersome installation procedure. Fischer, Harris & A ssoc ia tes 41

42 Pipe Companies Restraints US Pipe TR Flex Field Lok Field Lok 350 HD Lok Pac States - Thrust Lock PVC Pipe Certa Lock Bulldog Clow - Super Lock ACIPCO Fastite Flex Ring Lock Ring Fast Grip Field Flex Ring MJ Coupled Joint Griffin Snap Lok Mech Lok Bolt Lok 5/4/2012 Fischer, Harris & Associat es Non-Pipe Company Wedge Action Mechanical Joint Restraints EBAA Iron Megalug Ford Blockbuster Star Stargrip Tyler-Tuf Grip Romac Romagrip Sigma One Lock Smith Blair Cam Lock Sigma - PV Loc Fischer, Harris & Associat es 42

43 Mueller AquaGrip Tyler MJ Field Lock JCM 600 Series Smith Blair - Maxi Grip Romac Grip Ring One Bolt Friction Clamps Non - Wedge Action Restrainers All Trademarked names Fischer, Harris & Associat es How many different joint ways are there to restrain a joint? 43

44 Price Availability 44

45 Ease of Assembly Fischer, Harris & Associat es Quality Ductile Iron Ductile Iron is a composite metal that has special properties Ductile Iron Grey/Cast Iron A Little of both 45

46 Country of Origin From the Chelvis Website For the first time, the magnificent home of Chelvis has been made available to tour by the public. This 16 Acre estate which Chelvis has named Riceland, houses a full service laundromat, a 2 story rickshaw garage, as well as of course an all you can eat Chinese buffet. Riceland attracts 5 to 10 visitors a year from all over the world. 46

47 Reliable and Repeatable Installations Friction can interfere with the contact pressure of the wedge to pipe interface if the threaded parts are corroded or coated with thick asphaltic coatings Joint Restraints for for Ductile Iron Pipe Installation ease - Use AWWA C-600 to make seal then twist off lug bolt heads to restrain. Color Coded - Black Body, Blue Wedges Quality - Date and Production Coded-Proof of Metallurgy on Every Product (Made in USA?) Strength psi through above that Reliability Powder coatings on casting and Flourocarbon Coated Threaded Parts. 47

48 Joint Restraints for PVC pipe Installation ease - Use AWWA C-600 to make seal then twist off lug bolt heads to restrain. Color Coded Red Body, Blue Wedges Quality - Made in USA- Date and Production Coded-Proof of Metallurgy on Every Product Strength Rated the same as the pipe itself Reliability -Standard MEGABOND coating including Xylan Coated Threaded Parts. Joint Restraints for Push on Pipe EBAA Bell Harness Series

49 Joint Restraint for Couplings Hybrid-Coupling/Sleeve Restrained Sleeve for either Ductile Iron, PVC or Steel Pipe 49

50 1100 series Megalug Cast Iron-Grey Iron Pipe Restraint Needs to be structurally sound pipe Can ordered for oversized pipe Coated Gray for identification Technical Paper Available SPLIT Restraints 50

51 Polyethylene Pipe Restraint Considerations Expansion, Contraction and the Poisson effect can cause significant pipe movement. Fischer, Harris & Associat es Pipe on Bridge Crossings 51

Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe

Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe INFORMATION The Stargrip Mechanical Joint Restraint System is a unique product with a proven design that provides an exceptional

More information

Joint Restraints/ Bell & Spigot Joint/ New & In-Service Installations (2" IPS PVC Pipe)

Joint Restraints/ Bell & Spigot Joint/ New & In-Service Installations (2 IPS PVC Pipe) C 1 C 1.1 Joint Restraints/ Bell & Spigot Joint/ New & In-Service Installations (2" IPS PVC Pipe) Joint Restraints/ Bell & Spigot Joint/ New & In-Service Installations (AWWA C-900 PVC Pipe) C 1.1.1 Joint

More information

Section COUPLINGS AND COUPLING ADAPTERS. This Section covers couplings and coupling adapters for ductile iron and steel pipe.

Section COUPLINGS AND COUPLING ADAPTERS. This Section covers couplings and coupling adapters for ductile iron and steel pipe. PART 1 GENERAL 1.01 SUMMARY Section 15155 This Section covers couplings and coupling adapters for ductile iron and steel pipe. 1.02 MEASUREMENT AND PAYMENT A. No separate payment for Work performed under

More information

ONE-LOK Series SLC/SLCE Pipe Restraint for AWWA C909 PVC Pipe

ONE-LOK Series SLC/SLCE Pipe Restraint for AWWA C909 PVC Pipe ONE-LOK Series SLC/SLCE Restraint for AWWA Use the SIGMA ONE-LOK Series SLC/SLCE restraint for AWWA pipe at mechanical or push-on joint ductile iron fittings. The ONE-LOK Restraint Systems can successfully

More information

Pipe Restrainers series C Restrainers for use on IPEX Bionax AWWA CI OD C909 PVCO Pipe with MJ or Push-On Fittings

Pipe Restrainers series C Restrainers for use on IPEX Bionax AWWA CI OD C909 PVCO Pipe with MJ or Push-On Fittings Pipe Restrainers series 1000 1000C Restrainers for use on IPEX Bionax AWWA CI OD C909 PVCO Pipe with MJ or Push-On Fittings INFORMATION Restrainers for restraining mechanical joint or push-on fittings

More information

Pipe Restraints and Adapter Flanges. Section U. For PVC, Ductile Iron and Steel Pipe. 09/2017 Web Revision

Pipe Restraints and Adapter Flanges. Section U. For PVC, Ductile Iron and Steel Pipe. 09/2017 Web Revision DQS Inc. THE FORD METER BOX COMPANY, INC. CERTIFIED TO ISO 9001:2015 10004466 Section U 09/2017 Web Revision 11-29-17 Restraints and Adapter Flanges For PVC, Ductile Iron and Steel Contents Applications

More information

AMERICAN Ductile Iron Flex-Ring Joint Pipe Centrifugally Cast for Water, Sewage, or Other Liquids

AMERICAN Ductile Iron Flex-Ring Joint Pipe Centrifugally Cast for Water, Sewage, or Other Liquids AMERICAN Ductile Iron Flex-Ring Joint Pipe Centrifugally Cast for Water, Sewage, or Other Liquids 4-12 Flex-Ring Joint 14-54 Flex-Ring Joint AMERICAN Flex-Ring Restrained Joint Ductile Iron pipe, utilizing

More information

FIELD LOK 350 Gasket 4" 24"

FIELD LOK 350 Gasket 4 24 FIELD LOK 350 Gasket JOINT RESTRAINT FOR WATER & WASTEWATER, FIRE PROTECTION & INDUSTRIAL APPLICATIONS NSF P 2 Table of Contents FIELD LOK 350 Gasket 3 Assembly 4 Alternative Assembly Methods 7 Pipe Diameters

More information

FIELD LOK 350. Gasket 4" 24" JOINT RESTRAINT NSF FOR WATER & WASTEWATER, FIRE PROTECTION & INDUSTRIAL APPLICATIONS. Certified to ANSI/NSF 61

FIELD LOK 350. Gasket 4 24 JOINT RESTRAINT NSF FOR WATER & WASTEWATER, FIRE PROTECTION & INDUSTRIAL APPLICATIONS. Certified to ANSI/NSF 61 4" 24" FIELD LOK 350 JOINT RESTRAINT Gasket FOR WATER & WASTEWATER, FIRE ROTECTION & INDUSTRIAL ALICATIONS 4" 24" FIELD LOK 350 Gasket 2 Table of Contents FIELD LOK 350 Gasket 3 Assembly 4 Alternative

More information

DUCTILE IRON PIPE JOINTS AND THEIR USES

DUCTILE IRON PIPE JOINTS AND THEIR USES DUCTILE IRON PIPE JOINTS AND THEIR USES Ductile Iron Pipe Joints and Their Uses By Richard W. Bonds, P.E. DIPRA Research and Technical Director Introduction Joints for Iron pipe have come a long way. About

More information

FOR WATER & WASTEWATER, FIRE PROTECTION & INDUSTRIAL APPLICATIONS

FOR WATER & WASTEWATER, FIRE PROTECTION & INDUSTRIAL APPLICATIONS JOINT RESTRAINT (4" - 24") Gasket FOR WATER & WASTEWATER, FIRE ROTECTION & INDUSTRIAL ALICATIONS 866.DI.IE 2 Table of Contents Gasket 3 Assembly 4 Alternative Assembly Methods 7 ipe Diameters 8 Assembly

More information

Section 9 AMERICAN. Restrained Joint Pipe

Section 9 AMERICAN. Restrained Joint Pipe Section 9 AMERICAN Restrained Joint Pipe AMERICAN Restrained Joint Pipe The principal standards relating to applicable features of AMERICAN Restrained Joint Pipe and Fittings are ANSI/AWWA C151/A21.51,

More information

The Redi-Flange Method. How It Works. Services. Engineering & Costing Assistance

The Redi-Flange Method. How It Works. Services. Engineering & Costing Assistance ... g n ldi ng... e i W No hread ing! T oov o N Gr o N The Redi-Flange Method Redi-Flange is a method of joining valves, fi ttings and equipment with integral fl anged ends to plain-ended pipe, with all

More information

GENERAL PROVISIONS OF THE SPECIFICATIONS MATERIAL SPECIFICATIONS LIST

GENERAL PROVISIONS OF THE SPECIFICATIONS MATERIAL SPECIFICATIONS LIST GENERAL PROVISIONS OF THE SPECIFICATIONS MATERIAL SPECIFICATIONS LIST 1a. PIPE (PVCO): P.W. Eagle 200 PSI in accordance with AWWA C909. Use class 200 unless otherwise approved. Water Pipe Main Diameter

More information

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes MANHOLES PART I: GENERAL A. Precast Concrete Manholes 1) Manholes shall be made of precast concrete sections of which the top section shall be eccentric or flat slab top. The bottom section shall be a

More information

SPECIFICATION STEEL COUPLING MODEL 411

SPECIFICATION STEEL COUPLING MODEL 411 Sleeve Bolt Nut Follower Gasket 1/2 2 TWO BOLT 3 12 HIGH STRENGTH 2 12 SMALL O.D. 14 60 LARGE O.D. APPLICATIONS Typical Uses Joining plain-end pipe of same outside diameters Replace split or excessively

More information

AF-4 Grooved Flange Adapter

AF-4 Grooved Flange Adapter SUBMITTAL INFORMATION PROJECT NAME: ENGINEER: CONTRACTOR: SPEC. SECTION: MEMBER FEATURES & ADVANTAGES Designed for connecting ANSI/AWWA C110/A21.10 and ASME/ANSI B16.1 Class 125/ flanged end components

More information

SECTION 2. AMERICAN Pipe Joints

SECTION 2. AMERICAN Pipe Joints SECTION 2 AMERICAN Pipe Joints The AMERICAN Fastite Joint is a pushon type joint meeting all the rigorous requirements of AWWA C111. The ANSI/AWWA C600 Standard covers in detail the installation of ductile

More information

SAUSALITO-MARIN CITY SANITARY DISTRICT MISCELLANEOUS UPGRADES PROJECT. Addendum No. 2

SAUSALITO-MARIN CITY SANITARY DISTRICT MISCELLANEOUS UPGRADES PROJECT. Addendum No. 2 SAUSALITO-MARIN CITY SANITARY DISTRICT MISCELLANEOUS UPGRADES PROJECT Addendum No. 2 The following shall modify the Contract Documents. The work shall be accomplished in accordance with such modifications.

More information

General Information...SA1-SA4

General Information...SA1-SA4 SECTION S INDEX Product Description Page Number General Information................................................................SA1-SA4 Type FSK Thruwall & Floor Seal For Conduit, Pipe or Tubing............................

More information

Thru Wall Floor Seals For New Installation

Thru Wall Floor Seals For New Installation The O-Z/Gedney Thruwall and Floor Seals provide a positive means of sealing pipe, conduit or tube where they pass through a concrete foundation of a structure below grade or below ground water level or

More information

Section 2. AMERICAN Pipe Joints

Section 2. AMERICAN Pipe Joints Section 2 AMERICAN Pipe Joints AMERICAN Joints for Pipe and Fittings AMERICAN Fastite Joint, 4-64 The AMERICAN Fastite Joint, furnished in sizes 4-64, is a flexible, rubber ring compression-type joint

More information

TerraBrute CR (4-12 ) Pipe Installation Guide

TerraBrute CR (4-12 ) Pipe Installation Guide 1.0 Introduction TerraBrute CR is an integral-bell restrained-joint PVC pipe that meets the performance requirements of AWWA C900 (1). It has a slight modification that allows the joints to be locked for

More information

9. Construction Activities

9. Construction Activities 9. Construction Activities DIABLO WATER DISTRICT STANDARD SPECIFICATIONS AND DRAWINGS CONSTRUCTION ACTIVITIES I. Construction Sequence and Requirements II. Construction Submittal Checklist DIABLO WATER

More information

This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface.

This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface. SPEC-3500 1/9 1.0 PURPOSE This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface. Note: This specification does

More information

SECTION BASIC MATERIALS AND METHODS

SECTION BASIC MATERIALS AND METHODS SECTION 15050 BASIC MATERIALS AND METHODS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Pipe and Fittings. 1.02 RELATED SECTIONS A. Basic Mechanical Requirements: Section 15010. B. Supports, Anchors, and Seals:

More information

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification. Cast Iron Slide Gates Spec Sheet General The contractor shall furnish and install the following cast iron slide gate assemblies as listed on the Gate Schedule and detailed on the manufacturer s drawings.

More information

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING SECTION 230516 - EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

S W E RV E RAC K. Simple Security. Simple Stability.

S W E RV E RAC K. Simple Security. Simple Stability. S W E RV E RAC K Simple Security. Simple Stability. The Swerve Rack is a proven design that provides high security and easy bike parking. The Swerve Rack uses thick pipe construction and the full radius

More information

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. Hand or power. kpa/34.

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. Hand or power. kpa/34. MUELLER SMALL DRILLING MACHINES 2.1 Shaded area indicates change Rev. 9-09 MUELLER Co. manufactures several different small drilling machines for drilling holes from 7/16" to 2" in all types of pipe. Machines

More information

.1 Materials and installation for steel piping, valves and fittings for hydronic systems in building services piping..2 Related Sections.

.1 Materials and installation for steel piping, valves and fittings for hydronic systems in building services piping..2 Related Sections. Issued 2006/08/01 Section 15183 Hydronic Systems: Steel Page 1 of 6 PART 1 GENERAL 1.1 SUMMARY.1 Section Includes..1 Materials and installation for steel piping, valves and fittings for hydronic systems

More information

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING SECTION 230516 - EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING PART I - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

Figure 11 Flange Adapter and Back-Up Ring

Figure 11 Flange Adapter and Back-Up Ring Flange Adapters Standard back-up rings are Standard back-up rings are convoluted ductile iron with AWWA C207 150 lb drilling. One edge of the back-up ring bore must be radiused or chamfered. This edge

More information

SECTION MANHOLES

SECTION MANHOLES SECTION 02601 MANHOLES PART 1 GENERAL 1.01 SCOPE OF WORK A. WORK required under this section consists of all materials, accessories, equipment, tools, and labor required to install precast concrete standard

More information

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. The main is drilled out under pressure.

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. The main is drilled out under pressure. MUELLER SMALL DRILLING MACHINES 2.1 Rev. 9-09 MUELLER Co. manufactures several different small drilling machines for drilling holes from 7/16" to 2" in all types of pipe. Machines are available in hand

More information

H O O P RAC K. Simple Security

H O O P RAC K. Simple Security H O O P RAC K Simple Security The Hoop Rack is a proven design that provides high security and easy bike parking. The Hoop Rack uses thick pipe construction and the full radius of the bend makes the Hoop

More information

REPAIR CLAMP PARTS H fax: MULTIPLIER

REPAIR CLAMP PARTS H fax: MULTIPLIER REPAIR CLAMP PARTS Part Number Component Description Model Number Product Size List Price Unit V001 Neoprene Sheet Gasket AS All Sizes Square Inch V002 Waffle Pattern Gasket (NBR) AS All Sizes Square Inch

More information

Downtown Rack. Custom logo option available

Downtown Rack. Custom logo option available Custom logo option available Downtown Rack The Downtown Rack uses thick, square-tube construction that can t be cut with a pipe cutter. The extended width of the Downtown Rack makes for easy bike parking

More information

Swerve Rack CUSTOM RACKS AVAILABLE

Swerve Rack CUSTOM RACKS AVAILABLE CUSTOM RACKS AVAILABLE Swerve Rack The design of the Swerve mirrors the bike frame, thus providing superior bike support while making it easy to secure both the bike frame and wheel with a standard u-lock.

More information

UL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to "ORDER LENGTH" codes B through F; code A has 22" adjustment.

UL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to ORDER LENGTH codes B through F; code A has 22 adjustment. UL / FM MUELLER Indicator Post are used in fire protection systems and perform several functions. The Indicator Post provides a means to operate a buried or otherwise inaccessible valve. Also, the Indicator

More information

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8 September 2013 Page 1 of 8 Part 1 General 1.1 DESCRIPTION OF WORK.1 The work described herein shall consist of the construction of air release chambers, flushout chambers, valve chambers, meter chambers

More information

Appendix C Construction Details

Appendix C Construction Details 7172 Kennedy Road Warrenton, Virginia 20187 Appendix C Construction Details November 2017 TABLE OF CONTENTS THRUST BLOCKS Anchorage for 11 1/4 o, 22 1/2 o & 45 o Upper Vertical Bends... AV 01 Buttresses

More information

H O O P RAC K. Simple Security

H O O P RAC K. Simple Security H O O P RAC K Simple Security The Hoop Rack is a proven design that provides high security and easy bike parking. The Hoop Rack uses thick pipe construction and the full radius of the bend makes the Hoop

More information

Drilling machine Drilling machine for under pressure drilling Page Q 2/1 Motorised drilling machine Page Q 2/2

Drilling machine Drilling machine for under pressure drilling Page Q 2/1 Motorised drilling machine Page Q 2/2 TOOLS Page Q 2 Drilling machine Drilling machine for under pressure drilling Page Q 2/1 Motorised drilling machine Page Q 2/2 Page Q 3 Changeable carbide drill (WHM) Page Q 3/1 Drilling machine Tonisco

More information

ADDENDUM NO. 1 TO THE CONTRACT DOCUMENTS AND SPECIFICATIONS DATED JULY 2017 FLORIDA GOVERNMENTAL UTILITY AUTHORITY PROJECT NO.

ADDENDUM NO. 1 TO THE CONTRACT DOCUMENTS AND SPECIFICATIONS DATED JULY 2017 FLORIDA GOVERNMENTAL UTILITY AUTHORITY PROJECT NO. ADDENDUM NO. 1 TO THE CONTRACT DOCUMENTS AND SPECIFICATIONS DATED JULY 2017 FLORIDA GOVERNMENTAL UTILITY AUTHORITY PROJECT NO. PS 061 SEVEN SPRINGS WASTEWATER TREATMENT FACILITY IMPROVEMENTS PASCO COUNTY,

More information

Geberit Duofix. Installation Manual Montageanleitung Instructions de montage Istruzioni per il montaggio

Geberit Duofix. Installation Manual Montageanleitung Instructions de montage Istruzioni per il montaggio Geberit Duofix Installation Manual Montageanleitung Instructions de montage Istruzioni per il montaggio Masse Geberit Duofix Element für Wand-WC, cm, mit Sigma Unterputzspülkasten cm 9¾" (500) 4¾" (0)

More information

RELINER INSIDE DROP SYSTEM SPECIFICATIONS

RELINER INSIDE DROP SYSTEM SPECIFICATIONS 1. PRODUCT NAME RELINER INSIDE DROP SYSTEM U.S. Patent 6074130 Canadian Patent # 2269565 All RELINER Products are proudly made in the U.S.A. 2. MANUFACTURER RELINER /Duran Inc. 53 Mount Archer Rd. Lyme

More information

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC STANDARD SPECIFICATION SECTION 05121 MISCELLANEOUS METALWORK PART 1 - GENERAL 1.01 DESCRIPTION This section includes materials, fabrication, and installation of structural steel, connecting bolts, pipes,

More information

3.1 MUELLER LARGE DRILLING MACHINES

3.1 MUELLER LARGE DRILLING MACHINES MUELLER LARGE DRILLING MACHINES 3.1 Shaded area indicates change Rev. 1-09 Large Drilling Machines are used for making 2" to 24" lateral connections on water mains under pressure. These machines are available

More information

3.1 MUELLER LARGE DRILLING MACHINES

3.1 MUELLER LARGE DRILLING MACHINES MUELLER LARGE DRILLING MACHINES 3.1 Shaded area indicates change Rev. 1-09 Large Drilling Machines are used for making 2" to 24" lateral connections on water mains under pressure. These machines are available

More information

CSS Central Mount System

CSS Central Mount System CSS-20 Installation Manual CSS-20 Safety Notifications Below are the installation instructions for the CSS-20-2 Long Span Beam Mounting System. Please read these safety notifications prior to beginning

More information

This specification describes the minimum requirements for piping systems for the following service:

This specification describes the minimum requirements for piping systems for the following service: SPEC-3004 1/7 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Service Water Design Conditions Operating Conditions 10 PSIG @ 33 o F to

More information

Index Pipe Hangers and Straps

Index Pipe Hangers and Straps Index Pipe Hangers and Straps Fig. 1 Standard Clevis Hanger MSS-SP-69, Type 1 WW-H-171E, Type 1 Page 14 Fig. 1CI Clevis Hanger for A.W.W.A. Page 16 Fig. 81 Clevis Hanger WW-H-171E, Type 12 Page 70 Fig.

More information

CIC 200 PLASTIC SCREW ANCHOR ASSORTMENT WITH PHILLIPS BINDING HEAD METAL SCREWS. 6 x 3/4 P/N x 1 METAL SCREW P/N x 3/4 METAL SCREW

CIC 200 PLASTIC SCREW ANCHOR ASSORTMENT WITH PHILLIPS BINDING HEAD METAL SCREWS. 6 x 3/4 P/N x 1 METAL SCREW P/N x 3/4 METAL SCREW A21-1 1160 CIC 200 PLASTIC SCREW ANCHOR ASSORTMENT WITH PHILLIPS BINDING HEAD S For light duty applications in solid materials Color coded diameters for easy identifi cation Acid resistant NYLON FLANGED:

More information

SIGHT GLASS. Sight glass components allow operators to safely observe processes inside tanks, pipes, reactors and vessels.

SIGHT GLASS. Sight glass components allow operators to safely observe processes inside tanks, pipes, reactors and vessels. SIGHT GLASS Sight glass components allow operators to safely observe processes inside tanks, pipes, reactors and vessels. SIGHT GLASS Sight flow indicator. A sight flow indicator is used in process pipelines

More information

Assembly Instructions for Key-Lock mechanical joints in sizes 2 to 40 inch ( mm)

Assembly Instructions for Key-Lock mechanical joints in sizes 2 to 40 inch ( mm) Assembly Instructions for Key-Lock mechanical joints in sizes 2 to 40 inch (50-1000 mm) Introduction This guide provides recommendations for the installation of Bondstrand piping systems using the Key-Lock

More information

ALUMINUM PIPE GUIDERAIL 01/01/

ALUMINUM PIPE GUIDERAIL 01/01/ NOTES PIPE RAILING & POSTS: Structural Tube, Pipe and Bar shall be in accordance with ASTM B22 or ASTM B429, Alloy 606-T6. End Rail 90 bends and corner bends with maximum 4-0" post spacing, may be Alloy

More information

HUSSEY GAY BELL SAVANNAH, GEORGIA

HUSSEY GAY BELL SAVANNAH, GEORGIA HUSSEY GAY BELL SAVANNAH, GEORGIA ------------------------------------------------------------------------------------------------------------ ADDENDUM NO. 3 TO THE CONTRACT DOCUMENTS AND TECHNICAL SPECIFICATIONS

More information

STEEL PIPE GUIDERAIL 01/01/

STEEL PIPE GUIDERAIL 01/01/ NOTES PIPE RAILING & POSTS: Pipe Rails and s shall be in accordance with ASTM A5 Grade B for standard weight pipe and ASTM A500 Grade B, C or D or ASTM A50 for structural tube. Bars for handrail supports

More information

Tuf-Lite III Fans 5000K Series Hub

Tuf-Lite III Fans 5000K Series Hub Tuf-Lite III Fans 5000K Series Hub INSTALLATION MANUAL Hudson Tuf-Lite III fan blades Adjustable Pitch Fan Assembly 20 thru 30 Diameter Hudson Tuf-Lite III fan blades are of single piece fiberglass reinforced

More information

PVC PRESSURE PIPE TAPPING GUIDE

PVC PRESSURE PIPE TAPPING GUIDE PVC PRESSURE PIPE TAPPING GUIDE TABLE OF CONTENTS FOREWORD 03 INTRODUCTION 04 DIRECT TAPPING 09 SADDLE TAPPING 17 SLEEVE TAPPING 24 MEMBERS 29 2 UNI-BELL PVC PIPE ASSOCIATION WWW.UNI-BELL.ORG FOREWORD

More information

Tuf-Lite III Fans 5000K Series Hub

Tuf-Lite III Fans 5000K Series Hub Tuf-Lite III Fans 5000K Series Hub INSTALLATION MANUAL Hudson Tuf-Lite III fan blades Adjustable Pitch Fan Assembly 20 thru 30 Diameter Hudson Tuf-Lite III fan blades are of single piece fiberglass reinforced

More information

SYGEF Standard SYGEF Plus PVDF Flanges

SYGEF Standard SYGEF Plus PVDF Flanges Installation Instructions 2009 Volume, Rev 02 PM451 SYGEF Standard SYGEF Plus PVDF Flanges Please read all instructions before attempting to install flanges. Introduction When to Use a Flange Flanges may

More information

Evaluation of In-Pavement Light Fixture Designs and Performance

Evaluation of In-Pavement Light Fixture Designs and Performance Evaluation of In-Pavement Light Fixture Designs and Performance Presented to: IES ALC Fall Technology Meeting By: Joseph Breen Date: Background In-Pavement Light Fixture Assemblies Utilize a Circle of

More information

FIRE PROTECTION PRODUCTS

FIRE PROTECTION PRODUCTS FEATURES Rev. 7-11 Mueller Indicator Post are used in fire protection systems and perform several functions. The Indicator Post provides a means to operate a buried or otherwise inaccessible valve. Also,

More information

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

5/16 Flange nut. Bolt Keeper Plate (8 Sq. SYS.) (3) 1/2 x 3 Hex head connector zinc plated bolt w/ washers and nut. Anchor 3 sq. 7 Ga. 2 1/2" x 2 1/2" x 10 Ga. 6" 5" 4" Variable Slipbase (8" Sq. SYS.) 5/16 Corner Bolt W/ nut 5/16" Flange nut Stub Insert (8" Sq. SYS.) Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc

More information

MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C

MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C Revised October 2007 Armtec reserves the right to alter designs. General The Armtec Sluice Gate is a quality and highly economical gate for a variety of

More information

Section 914. JOINT AND WATERPROOFING MATERIALS

Section 914. JOINT AND WATERPROOFING MATERIALS 914.01 Section 914. JOINT AND WATERPROOFING MATERIALS 914.01. General Requirements. Joint and waterproofing material for use in concrete construction must meet the requirements of this section. 914.02.

More information

Max. Rec. Load. Wt. Per Inch lbs. kn lbs. kn lbs. kg. Wt. Per Inch lbs. kn lbs. kn lbs. kg 750 F (399 C)

Max. Rec. Load. Wt. Per Inch lbs. kn lbs. kn lbs. kg. Wt. Per Inch lbs. kn lbs. kn lbs. kg 750 F (399 C) FIG. 10 FIG. 15 & 15L Function: Designed for use in pipe hanger assemblies. (Type 304 or 316 Stainless Steel upon request) Ordering: Specify figure number, rod size, length (), material, and finish. 650

More information

Sprinkler wet pipe and dry pipe. For FM approval of the dry pipe model "I" shall be used. SBF 120: 7 applies to model "E".

Sprinkler wet pipe and dry pipe. For FM approval of the dry pipe model I shall be used. SBF 120: 7 applies to model E. Product Name Nordic Flow FM Thin Wall Pipes Application Sprinkler wet pipe and dry pipe. For FM approval of the dry pipe model "I" shall be used. SBF 120: 7 applies to model "E". Manufacturing Standard

More information

Utility Structures. Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles

Utility Structures. Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles Utility Structures Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles PRODUCT GUIDE & TECHNICAL REFERENCE MANUAL Providing the right solutions. UTILITY STRUCTURES Perfect

More information

A. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures.

A. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures. SECTION 22 05 16 LOOPS FOR PLUMBING PIPING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Ford Water Meter Couplings & Accessories

Ford Water Meter Couplings & Accessories Section H 2/2001 Ford Water Meter Couplings & Accessories The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 260/563-3171 FAX: 1-800-826-3487 Overseas

More information

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 270536 - CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Rodney Hunt. A GA Industries Company Glydaseal Gates

Rodney Hunt. A GA Industries Company Glydaseal Gates Rodney Hunt A GA Industries Company Glydaseal Gates GUIDE BRONZE GUIDE BAR FRAME NUT POCKET SEAT FACING RESILIENT INVERT SEAT DISC GUIDE BAR ADJUSTMENT BOLT WITH LOCK NUT GUIDE BAR ATTACHING BOLT The Glydaseal

More information

SECTION METAL FABRICATIONS

SECTION METAL FABRICATIONS SECTION 05100 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for metal fabrications, including minimum requirements for fabricator, and galvanizing. 1.02 REFERENCE STANDARDS A. ASTM

More information

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence MILWAUKIE OR #3144-00 ADDENDUM #5 NARRATIVE: 11-08-12 WAL-MART SUPERCENTER #3144-00; Milwaukie, OR: SPECIFICATIONS SPECIFICATIONS Revisions to Specification 02822 Fence Spec division 02822 has been revised

More information

PAC-12 Kit Contents. Tools Needed Soldering iron Phillips screwdriver Wire stripper Wrenches, 7/16 and 1/2 Terminal crimp tool Pliers Solder

PAC-12 Kit Contents. Tools Needed Soldering iron Phillips screwdriver Wire stripper Wrenches, 7/16 and 1/2 Terminal crimp tool Pliers Solder PAC-2 Kit Contents Part Quantity Screws: 8/32 x 3/8 Screws: 8-32 x 5/6 Screw: 8-32 x /4 #8 internal tooth washers #8 solder lug ring terminals Bolt: Aluminum, /4-20 x.5 /4 internal tooth washer Nut: Aluminum

More information

HOOP RACK HEAVY DUTY Setbacks WALL 36" WALL 42" 36" STREET 59" STREET Dero

HOOP RACK HEAVY DUTY Setbacks WALL 36 WALL 42 36 STREET 59 STREET Dero Setbacks WALL 36" WALL 42" STREET 36" 59" STREET Installation Instructions Tape Measure Marker or Pencil Masonry Drill Bit Drill (Hammer drill recommended) Hammer Wrench 9/16 Level RECOMMENDED BASE MATERIAL

More information

This specification describes the minimum requirements for piping systems for the following service:

This specification describes the minimum requirements for piping systems for the following service: 201/01/13 1/ 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Service Air Design Conditions Operating Conditions Blast Air (see Note 1)

More information

Tuf-Lite III Fans 3000K Series Hub

Tuf-Lite III Fans 3000K Series Hub Tuf-Lite III Fans 3000K Series Hub INSTALLATION MANUAL Adjustable Pitch Fan Assembly 11 thru 15 Diameter Hudson Tuf-Lite III fan blades Hudson Tuf-Lite III fan blades are of single piece fiberglass reinforced

More information

5.1 MUELLER CORPORATION VALVES. MUELLER 300 Ball Type Corporation Valves

5.1 MUELLER CORPORATION VALVES. MUELLER 300 Ball Type Corporation Valves MUELLER CORPORATION VALVES 5.1 Shaded area indicates changes Rev. 4-14 Machine inserted corporation stops were developed by Hieronymus Mueller in conjunction with his development of the drilling and tapping

More information

Tuf-Lite II Fans 3000H Series Hub

Tuf-Lite II Fans 3000H Series Hub Tuf-Lite II Fans 3000H Series Hub INSTALLATION MANUAL Adjustable Pitch Fan Assembly 5 through 14 Diameter Hudson Tuf-Lite II Fan Blades Hudson Tuf-Lite II (white, prev. Blue**) are made from fiberglass

More information

Assembly instruction. for push-in joint pipe DN mm with internal restrained joint Fig. 2807A / 2807B

Assembly instruction. for push-in joint pipe DN mm with internal restrained joint Fig. 2807A / 2807B Assembly instruction for push-in joint pipe DN 80-500 mm with internal restrained joint Fig. 2807A / 2807B 1. General remarks Following the instructions below will guarantee correct and professional assembly.

More information

Assmann Corporation of America TANK INSTALLATION AND USE GUIDELINES FOR BULK STORAGE TANKS

Assmann Corporation of America TANK INSTALLATION AND USE GUIDELINES FOR BULK STORAGE TANKS Assmann Corporation of America TANK INSTALLATION AND USE GUIDELINES FOR BULK STORAGE TANKS General Information Assmann polyethylene storage tanks are manufactured to give you the toughest, most reliable

More information

INSTALLATION INSTRUCTIONS. March 2016 FOR FURTHER QUESTIONS, PLEASE CALL

INSTALLATION INSTRUCTIONS. March 2016 FOR FURTHER QUESTIONS, PLEASE CALL March 2016 INSTALLATION INSTRUCTIONS FOR FURTHER QUESTIONS, PLEASE CALL 775 440 2025 JENSEN WATER RESOURCES 521 Dunn Circle, Sparks, NV 89431 JensenPumps.com Figure 1: This illustration shows a complete

More information

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub INSTALLATION MANUAL Hudson Tuf-Lite and Tuf-Lite II fan blades Adjustable Pitch Fan Assembly 15 thru 20 Diameter Hudson Tuf-Lite (black) fan blades are made

More information

Tuf-Lite II Fans 3000H Series Hub

Tuf-Lite II Fans 3000H Series Hub Tuf-Lite II Fans 3000H Series Hub INSTALLATION MANUAL Adjustable Pitch Fan Assembly 5 through 14 Diameter Hudson Tuf-Lite II Fan Blades Hudson Tuf-Lite II (white, prev. blue**) fan blades are made from

More information

SECTION 7. SAFETYING

SECTION 7. SAFETYING 9/8/98 AC 43.13-1B SECTION 7. SAFETYING 7-122. GENERAL. The word safetying is a term universally used in the aircraft industry. Briefly, safetying is defined as: Securing by various means any nut, bolt,

More information

Tuf-Lite II Fans 3000HC Series Hub

Tuf-Lite II Fans 3000HC Series Hub Tuf-Lite II Fans 3000HC Series Hub INSTALLATION MANUAL Hudson Tuf-Lite II fan blades Adjustable Pitch Fan Assembly 8 through 10 Diameter Hudson Tuf-Lite II (White) are made from fiberglass reinforced vinyl-ester

More information

American Safe Room. Explosion Resistant Blast Hatch with Integrated Riser

American Safe Room. Explosion Resistant Blast Hatch with Integrated Riser American Safe Room Explosion Resistant Blast Hatch with Integrated Riser Drawing: ASR-50-RBH Revision: H May 17, 2012 Table of Contents Description... 3 Options... 4 Order form... 5 Option: left or right

More information

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub INSTALLATION MANUAL Hudson Tuf-Lite and Tuf-Lite II fan blades Adjustable Pitch Fan Assembly 15 thru 20 Diameter Hudson Tuf-Lite (black) fan blades are made

More information

ANSI ORIFICE FLANGES METAL-KOREA

ANSI ORIFICE FLANGES METAL-KOREA METAL-KOREA ANSI ORIFICE FLANGES ORIFICE FLANGES are widely used in conjunction with orifice meters for measuring the rate of flow of liquids and gases. They are basically the same as standard welding

More information

UPDATE LOG FOR STANDARD DRAWINGS Item(s) Changed 6/1/18 STANDARD DRAWINGS

UPDATE LOG FOR STANDARD DRAWINGS Item(s) Changed 6/1/18 STANDARD DRAWINGS Date 6/1/18 STANDARD DRAWINGS UPDATE LOG FOR STANDARD DRAWINGS Item(s) Changed WATER STANDARD DRAWINGS Title Drawing Number Current Date Fire Hydrant and Appurtenance Locations, Improved Streets with Curb

More information

TYPHOON ASSEMBLY AND INSTALLATION INSTRUCTIONS

TYPHOON ASSEMBLY AND INSTALLATION INSTRUCTIONS TYPHOON ASSEMBLY AND INSTALLATION INSTRUCTIONS CORPORATE HEADQUARTERS WESTERN SALES AND MANUFACTURING PLANT P.O. Box 400 1017 SW Berg Parkway Canby, Oregon 97013 Phone: (503) 266-2231 Fax: (503) 266-4334

More information

Structural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the grade A325 structural bolt.

Structural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the grade A325 structural bolt. Structural Bolting ASTM F3125/F3125M is a structural bolt specification covering inch and metric bolt grades. This specification contains 4 inch series bolting grades: A325, F1852, A490, and F2280. These

More information

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018 SECTION 055000 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Tuf-Lite III Fans K Hi Temp 3000KHT Series Hub

Tuf-Lite III Fans K Hi Temp 3000KHT Series Hub Tuf-Lite III Fans K Hi Temp 3000KHT Series Hub INSTALLATION MANUAL Adjustable Pitch Fan Assembly 11 thru 15 Diameter Hudson Tuf-Lite III fan blades Hudson Tuf-Lite III Hi Temp (Red) fan blades are of single

More information

THE AquaBlast & RocketRide FUNSLIDES

THE AquaBlast & RocketRide FUNSLIDES THE AquaBlast & RocketRide FUNSLIDES ASSEMBLY AND INSTALLATION INSTRUCTIONS * * C A U T I O N * * S.R. SMITH AquaBlast TM & RocketRide TM FUNSLIDES TM ARE MANUFACTURED FOR INSTALLATION AND USE ON RESIDENTIAL

More information

SECTION PRECAST CONCRETE SECTIONAL MANHOLES

SECTION PRECAST CONCRETE SECTIONAL MANHOLES SECTION 02545 PRECAST CONCRETE SECTIONAL MANHOLES PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Precast reinforced concrete cylindrical sectional manholes, complete with openings, inserts, hardware,

More information