SCHMIDT Flow Sensor SS Quick Guide
|
|
- Gavin Cannon
- 5 years ago
- Views:
Transcription
1 SCHMIDT Flow Sensor SS Quick Guide
2 SCHMIDT Flow Sensor SS Table of Contents 1 Important information Application range Assembly Electrical connection Commissioning Calculation of volume flow... 7 Imprint: Copyright 2017 SCHMIDT Technology All rights reserved Version: B Subject to modifications Quick Guide SS Page 2
3 1 Important information This quick guide must be read completely and observed carefully, before putting the unit into operation. For detailed information on mounting and operation of the sensor, please refer to the detailed instructions for use ( ) available on the internet under or ( Sensors Downloads). In case of doubt, please observe the information given there. Any claims under the manufacturer's liability for damage resulting from non-observance or non-compliance with these instructions will become void. Tampering with the device in any way whatsoever - with the exception of the designated use and the operations described - will forfeit any warranty and exclude any liability. The unit is designed exclusively for the use described below (refer to chapter 2). In particular, it is not designed for direct or indirect protection of personal or machinery. SCHMIDT Technology cannot give any warranty as to its suitability for a certain purpose and cannot be held liable for accidental or sequential damage in connection with the delivery, performance or use of this unit. 2 Application range The SCHMIDT flow sensor SS is designed for stationary measurement of the flow velocity as well as the air and gas temperature. The sensor measures the normal velocity w N (unit: m/s), based on normal conditions of hpa and 20 C. The output signal is linear and independent from the pressure and temperature of the medium to be measured. When using the sensor outdoors, it must be protected against direct exposure to the weather. The additional ATEX instructions must be read and observed carefully when using the sensors in ATEX areas. Information and safety instructions for the use in media having an oxygen percentage of > 21 % can be found in the instructions for use. Quick Guide SS Page 3
4 3 Assembly Determination of installation site The sensor should preferably be installed in horizontal pipes. Avoid installing the sensor in a pipe with downward flow. For w N < 2 m/s Correct measurements require a flow low in turbulence. This can be achieved by providing sufficiently long and straight distances without disturbances in front of and behind the sensor. The minimum inlet and outlet distances are defined by the type of the flow obstacle upstream of the measuring distance and the inner pipe diameter. Flow obstacle upstream of the measuring distance Minimum length inlet (L1) Minimum length outlet (L2) Light bend (< 90 ) 10 x D 5 x D Reduction / expansion / 90 bend or T-junction 15 x D 5 x D Two 90 bends in one plane (2-dimensional) 20 x D 5 x D Two 90 bends (3-dimensional change in direction) 35 x D 5 x D Shut-off valve 45 x D 5 x D Quick Guide SS Page 4
5 Installation The sensor may only be mounted and dismounted when no pressure is applied. Quick Guide SS Page 5
6 In case of mechanical strain (vibration), the nut must be secured additionally (e.g. using a screw lock). The aligning surface of the housing must not be used for securing. The pressure-tight mounting, the fastening of the screw pipe connection and the discarding protection must be checked before pressure is applied. This check must be repeated periodically. The components of the pressure protection kit (bolt, chain and bracket) have to be checked regularly for integrity. If the sensor head is immersed in water and operated under pressure, the sensor may be damaged irreversibly. 4 Electrical connection Make sure that no operating voltage is active during electrical installation and that the operating voltage cannot be switched on inadvertently. View of plug-in connector of the sensor For operating the sensor, a supply voltage of 24 V DC ± 20 % is required. For more information, please refer to the detailed instructions for use ( , page 21 et. seq.). Quick Guide SS Page 6
7 Pin Designation Function Wire colour 1 Pulse 1 Output signal Flow (digital: pulse) White 2 U B Operating voltage: 24 V DC ± 20% Brown 3 Analog T M Output signal Temperature of medium (analog: U / I) Green 4 Analog w N Output signal Flow (analog: U / I) Yellow 5 AGND Reference potential for analog outputs Gray 6 Pulse 2 Galvanically decoupled pulse output Pink 7 GND Operating voltage: Ground Blue 8 Pulse 2 Galvanically decoupled pulse output Red Table 1 The specified wire colors are valid when one of the SCHMIDT connecting cables is used. The analog outputs switch automatically between the operation as voltage interface (0 10 V) and current interface (4 20 ma). The switching threshold is set to a measuring resistance between 500 and 550 Ω. 5 Commissioning The valid measuring ranges and the configuration of the signal outputs are specified on the rating plate. After applying the supply voltage, the sensor signals the initialization of the measuring operation by means of all four LEDs (sequence: red, orange, green). The flow output signal will at first adopt a higher value and then settle to the correct measurement value after about 10 seconds. LEDs flashing in red indicate an error. For detailed error description, please refer to the instructions for use. 6 Calculation of volume flow SCHMIDT Technology provides a convenient calculation tool to compute flow velocity or volume flow in pipes for all its sensor types and measuring ranges. This Flow Calculator can be directly used on or downloaded from SCHMIDT homepage: or Quick Guide SS Page 7
8 SCHMIDT Technology GmbH Feldbergstrasse St. Georgen Germany Phone +49 (0)7724 / Fax +49 (0)7724 / sensors@schmidttechnology.de URL Quick Guide SS Page 8
Flow sensor HVAC 100 (548000) Instruction for use. Imprint: Copyright all rights reserved Version Subject to modifications
Flow sensor HVAC 100 (548000) Instruction for use Imprint: Copyright 2017 - all rights reserved Version 547996.02 Subject to modifications Important Information These instructions for use must be read
More informationSCHMIDT Flow Sensor SS Instructions for Use
SCHMIDT Flow Sensor SS 20.651 Instructions for Use SCHMIDT Flow Sensor SS 20.651 Table of contents 1 Important information... 3 2 Application range... 3 3 Mounting... 4 4 Electrical connection... 7 5 Commissioning...
More informationSCHMIDT Flow Sensor SS Instructions for Use
SCHMIDT Flow Sensor SS 20.250 Instructions for Use SCHMIDT Flow Sensor SS 20.250 Table of Contents 1 Important Information... 3 2 Application range... 4 3 Mounting instructions... 4 4 Electrical connection...
More informationSCHMIDT. VibroSens 401. Operating Instructions
SCHMIDT VibroSens 401 Operating Instructions SCHMIDT Vibration Control VibroSens 401 Operating Instructions 1 Important information... 3 2 Use... 4 3 Description of functions... 5 4 Installation... 10
More informationDigital flow ELEMENT transmitter for continuous flow measurement
ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor
More informationSCHMIDT Flow Sensor SS 25.60
Product description Product advantages Form 107/06/09/1000/3 Art. No. 511 047.02 A Data subject to change The flow sensor is a mass flow sensor (thermal anemometer), designed for use in oxygen. Due to
More informationDigital flow ELEMENT transmitter for continuous flow measurement
Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single
More informationTorque Sensor Series 3000 and Series 4000
Properties Sensorshaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement range
More informationWATERFLUX 3000 Quick Start
WATERFLUX 3000 Quick Start Electromagnetic flowmeter The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000
More informationMelt pressure Transmitter GREENLINE Type DTAI with Temperature element
Melt pressure Transmitter GREENLINE Type DTAI with Temperature element Operation and Maintenance Manual English Mercury free NaK free Seite 1 / 9 Contents: 1. Introduction 2. Operating range and field
More informationMagnetic Inductive Flow Sensor induq
Operating manual (Translation) Operating manual... page 1-16 Magnetic Inductive Flow Sensor induq Series VMZ SIKA Ba_VMZ_en 10/2014. Please keep this operating manual for future reference. If the device
More informationWATERFLUX 3000 Quick Start
WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000
More informationSeries 7000 Torque Sensor for PTO-shafts
Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Special for PTO shafts 1 ¾ und 1 3/8 Plug & Play solution, no additional
More informationMODEL 1703E THE CHAMBERLAIN ARM TM INSTALLATION INSTRUCTIONS To be used in conjunction with the Lift-Master Garage Door Operator Owner's Manual
MODEL 1703E THE CHAMBERLAIN ARM TM INSTALLATION INSTRUCTIONS To be used in conjunction with the Lift-Master Garage Operator Owner's Before you begin, please read this ENTIRE instruction manual. One- Piece
More informationph or ORP Transmitter
ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes
More informationWind Direction Transmitter First Class analogue output x0.1xx
THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021514/03/09 Wind Direction Transmitter First Class analogue output 4.3150.x0.1xx ADOLF THIES GmbH
More informationFLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual
SWITCH 600 Series Velocity Flow Sensor Instruction Manual Ultrasonic Velocity Sensor using Doppler Technology Model: FS-600 Manual Release Date: November, 2009 ECHO Process Instrumentation, Inc. CONTENTS
More informationElectromagnetic Flow Transmitter
Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be
More informationExternal brake resistor AX2090-BW5x
Documentation External brake resistor AX2090-BW5x Accessories for Beckhoff servo drive AX5000 Version: Date: 1.3 2018-03-14 Table of content Table of content 1 Foreword... 5 1.1 Notes on the documentation...
More informationPOSIROT. PRAS3EX Magnetic Angle Sensor. Magnetic Angle Sensors (Dust-Ex-proof) Datasheet
Magnetic Angle Sensors (Dust-Ex-proof) Magnetic Angle Sensor Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does not form part of
More informationVIT SB-16SS Pedestal. Conversion Guide
Converting a to Baseline This guide describes the steps for removing another manufacturer s irrigation controller from a VIT SB-16SS pedestal and installing a Baseline controller. Remove All Parts of the
More informationCDG. Carbon Dioxide - User Manual Gas Detector. 1 Intended Use. 2 Functional Description. 3 Installation. 4 Electrical Connection.
Carbon Dioxide - User Manual 1 Intended Use 2 Functional Description 2.1 Control Mode 2.2 Sensor 3 Installation 3.1 Mounting instructions 3.2 Installation 4 Electrical Connection 4.1 Instruction 5 Commissioning
More informationK1FO 12 ELEMENT 144/147 MHz YAGI
K1FO 12 ELEMENT 144/147 MHz YAGI WARNING: INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS. FOR YOUR SAFETY FOLLOW THE INSTALLATION DIRECTIONS. Ariane Arrays, Inc. Copyright 2006 201 Hopedale
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationSCHMIDT Flow Sensor SS SS FB
Product description Flow sensor with integrated microcontroller transducer for the measurement of air-flow velocity and for the determination of the flow rate and flow volume. The aerodynamically styled
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationWind Transmitter - with analogue output xxx
THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for use 020856/10/07 Wind Transmitter - with analogue output 4.3303.22.xxx ADOLF THIES GmbH & Co. KG Hauptstraße
More informationMHz Base Station Antennas for Mobile Communications
27 512 MHz Base Station Antennas for Mobile Communications Photo on title page: Applications for TETRA. Catalogue Issue /4 All data published in previous catalog issues hereby becomes invalid. We reserve
More informationAir Quality Sensor KNX AQS
Air Quality Sensor KNX AQS Installation and Adjustment 1 Content 1. Description... 3 1.0.1. Measurement of carbon dioxide in the air... 3 1.1. Technical specifications... 4 2. Installation and commissioning...
More informationArc Sensor User Manual
MN026008EN Arc Sensor User Manual EAFR-01 EAFR-06 EAFR-08 EAFR-07 DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document
More informationSeries B Medical Gas Service Outlet Upgrade Kits
Installation Instructions Series B Medical Gas Service Outlet Upgrade Kits For additional information concerning operation of Puritan Bennett Series B Quick-Connect Outlet Valves, refer to Operating Instructions
More informationLENORD. +BAUER... automates motion. GEL 2444K PG Configurable rotational speed and position sensor with operating hours counter
GEL 2444K PG Configurable rotational speed and position sensor with operating hours counter LENORD +BAUER... automates motion. Technical information Version 2015-03 General The measuring system comprises
More informationFMG70B Series Magnetic Inductive Flow Sensor
. FMG70B Series Magnetic Inductive Flow Sensor - 2 - M-5575/0416 Table of contents page 0 About this operating manual...4 1 Device description...5 1.1 Delivery, unpacking and accessories...5 1.2 Intended
More informationPlease read and understand the OnBoard Timpani Cart Owner s Manual before using the Timpani Cart.
Assembly and Owner s Manual OnBoard Timpani Cart Performance Position Towing Position CONTENTS Important User Information...........................2 General......................................2 Manufacturer.................................2
More informationDigital flow transmitter for continuous flow measurement
Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:
More informationWind Transmitter - compact
THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021194/02/07 Wind Transmitter - compact 4.3518.03.000 4.3519.03.000 ADOLF THIES GmbH & Co. KG Hauptstraße
More informationOperating Instructions K-POWERgrip EWL Always on the safe site.
Operating Instructions K-POWERgrip EWL 4941. Always on the safe site. KaVo Elektrotechnisches Werk GmbH Wangener Straße 78 D-88299 Leutkirch A 1 User information...2 A 1.1 Meaning of the pictograms...2
More informationWind Direction Transmitter - compact - GMR, analogue output xxx
THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021488/02/06 Wind Direction Transmitter - compact - GMR, analogue output - 4.3129.60.xxx ADOLF THIES
More informationInstallation Instructions Student 101 Fume Cupboard
Installation Instructions Student 101 Fume Cupboard Refer drawing on next page 0. If your fume cupboard is supplied with a flatpack bench frame, see step1. If your fume cupboard will be mounted on an existing
More informationGE Interlogix Fiber Options S714D & S7714D. Instruction Manual FIBER-OPTIC NETWORK TRANSMISSION SYSTEM
g GE Interlogix Fiber Options Instruction Manual & S7714D FIBER-OPTIC NETWORK TRANSMISSION SYSTEM Federal Communications Commission and Industry Canada Radio Frequency Interference Statements This equipment
More informationSole Fitness E95 Elliptical Trainer TurnKey Delivery and Setup Training
Sole Fitness E95 Elliptical Trainer TurnKey Delivery and Setup Training Delivery Requirements Ground delivery Inside delivery to customer-specified location Unpack and assemble machine, and remove packing
More informationINSERTION paddle wheel flowmeter for continuous flow measurement
INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both
More informationData sheet. P3 Top Class BlueLine. P3MBP BlueLine. Ultra-high pressure transducers to 15,000 bar. Special features
Ultra-high pressure transducers to 1,000 bar Data sheet Special features P Top Class BlueLine PMBP BlueLine - For static and dynamic pressure variance, pressure peaks and pressure fluctuations - Principle
More informationUser Manual. PolyGard AT-2000 V3. Infrared Refrigerant Gas Transmitter Serial No. AT March, 2009
PolyGard AT-2000 V3 Infrared Refrigerant Gas Transmitter Serial No. AT-2000 User Manual March, 2009 February 16, 2016 Revision Specifications subject to change without notice. USA 160216 Page 2 of 13 1
More informationLENORD. +BAUER... automates motion. MiniCoder GEL 2444K Speed and position sensor with metal housing and sin/cos output
MiniCoder GEL 2444K Speed and position sensor with metal housing and sin/cos output LENORD +BAUER... automates motion. Technical information Version 03.3 General The measuring unit comprises a sensor and
More informationConductivity Transmitter
Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants
More informationeye in hell CD 3002 Sensor Manual
Your eye in hell CD 3002 Sensor Manual Siemens Laser Analytics AB Oct 2001 CD 3002 Sensor manual Document number: CID 3002-1102 Rev. 2A LDS 3000 Sensor manual Content Content 1. CD 3002 1 1.1 General 1
More informationLENORD. MiniCODER plus GEL 2449 Configurable rotational speed and position sensor with operating hours counter. +BAUER... automates motion.
MiniCODER plus GE 2449 Configurable rotational speed and position sensor with operating hours counter ENORD +BAUER... automates motion. Technical information Issued 2017-05 General The measuring system
More informationFMG90 Series Electromagnetic Flow Meter
. FMG90 Series Electromagnetic Flow Meter - 2 - Series FMG90 Series FMG90 Table of contents page 0 About this operating manual... 4 1 Device description... 5 1.1 Delivery, unpacking and accessories...
More informationWLL 170 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC. Dimensional drawing R1.6 2-R
WLL 0 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC 0... 0 mm Through-beam systems Dimensional drawing R. -R. Scanning distance 0... 0 mm. Proximity systems
More informationDouble-Ridged Waveguide Horn Antennas
Models 3112, 3106B, 3119, 3115, 3117, 3116C Double-Ridged Waveguide Horn Antennas User Manual ETS-Lindgren Inc. Although the information in this document has been carefully reviewed and is believed to
More informationFST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL
FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL 20020628 CONTENTS DESCRIPTION... 3 OPERATION... 4 Power Supply...4 Output Range...4 Temperature Operating Range and Temperature Limits...4
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationNew Product Release: October 2014 Boone Racks
New Product Release: October 2014 Boone Racks Double Fido Fountain Mounting: Surface NOTE: THESE ROUGH-IN DIMENSIONS MAY VARY ½: (13 mm) PLUS OR MINUS NOTE: All dimensions subject to manufacturing variance
More informationOnBoard Bass Drum/Gong Cart
Assembly and Owner s Manual OnBoard Bass Drum/Gong Cart CONTENTS Important User Information...................................................................2 Safety...................................................................................3
More informationWind Transmitter - with frequency output xx.xxx
THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021531/11/09 Wind Transmitter - with frequency output 4.3303.xx.xxx ADOLF THIES GmbH & Co. KG Hauptstraße
More informationVAN STORAGE SOLUTIONS FOR THE WAY YOU WORK
WWW.WEATHERGUARD.COM VAN STORAGE SOLUTIONS FOR THE WAY YOU WORK Weather Guard / KNAACK 420 E. Terra Cotta Ave. Crystal Lake, IL 60014 USA 800-456-7865 (Toll Free) 800-334-2981 (Fax) Knaack.OrderEntry@wernerco,.com
More informationGP-SD GENIE PROBE SMALL DIAMETER
For GENIE PROBE SMALL DIAMETER Installation and Operation Instructions 2 for s Locking Mechanism (if supplied) Set Screws Backed Out To ensure that the is Locking never accidentally loosened or Mechanism
More informationWind Direction Transmitter - compact - GMR, analogue output xxx xxx
THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021488/06/09 Wind Direction Transmitter - compact - GMR, analogue output - 4.3129.60.xxx 4.3129.80.xxx
More informationInstallation and operating instructions
Installation and operating instructions GPS TILT-Module Version: V3.20120515 30302495-02-EN Read and follow these operating instructions. Keep these operating instructions in a safe place for later reference.
More informationInstruction Manual Inductive Gauging Sensor
Instruction Manual Inductive Gauging Sensor EX-200 Series 96M0367 CONTENTS Page Part names and functions...3 Connections/Hints on correct use... 4 Installations... 5 Adjustment... 6 Specifications... 7
More informationWind Direction Transmitter - compact
THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021542/06/05 Wind Direction Transmitter - compact 4.3129.03.141 4.3129.53.141 ADOLF THIES GmbH & Co.
More informationAssembly instructions Pantograph shutters
Assembly instructions Pantograph shutters Read these instructions, observe the contents and the warning notes prior to assembly. The information is very important for installation and correct use of the
More informationWeather Station for KNX
Weather Station for KNX Installation and Adjustment Product description... 3 Technical data... 3 PCB layout...5 230 V AC version... 5 24 V DC version... 6 Installation and commissioning... 7 Location...
More informationTECHNICAL INSTRUCTIONS
0 TECHNICAL INSTRUCTIONS Innovation Anode Retrofit Instructions This kit applies to all Innovation model water heaters ITEM 1: P/N 44173 ANODE MOUNTING BRACKET ITEM 2: P/N 44174 ANODE BLOCK (2 each) ITEM
More informationExpressTray. Steel Wire Basket Tray. Configuration Methods. B Connection of Straight Sections. A Quiklok Tray Connections at Record Speed
A Quiklok Tray Connections at Record Speed B Connection of Straight Sections In any project, installation time is key. Our patented QuikLok tray profile connects straight lengths of tray at record speed.
More informationSICLOCK DCFRS Industrial Version with TTY Interface 2XV9450-1AR21
SICLOCK DCFRS Industrial Version with TTY Interface 2XV9450-1AR21 User Manual Version 1.2 Revision: May 2014 Order No. 2XV9450-1AR48 Contact Person: Orders: local SIEMENS branch local SIEMENS branch Published
More informationFP-4855 Flat Panel Television Stand ASSEMBLY INSTRUCTIONS
FP-4855 Flat Panel Television Stand ASSEMBLY INSTRUCTIONS Patent Pending Italian Designed A Product of China Do not discard these instructions M-1_051607v3 Bell O International Corp. will not be responsible
More informationINSTALLATION GUIDE. Yellow Jacket Oscillator. For help, call BIG-FANS or visit
INSTALLATION GUIDE Yellow Jacket Oscillator For help, call 1-877-BIG-FANS or visit www.bigassfans.com READ AND SAVE THESE INSTRUCTIONS WARNING AND CAUTION SYMBOL Indicates a hazard with a medium level
More informationTK 1014 A POWER SHEAR
TIN KNOCKER TK 1014 A POWER SHEAR Parts Diagram & Operating Instructions TAAG INDUSTRIES CORP. 1550 SIMPSON WAY, ESCONDIDO, CA 92029 Tel: (800) 640-0746 Fax: (760) 727-9948 Website: www.tinknocker.com
More informationAccessories for sensors
Accessories for sensors Mounting and installation Adapters for pressure sensors: Hex AF width 27 ZBM 01 Adapter female thread G1/4 male thread G1/2 B, DIN EN 837-1 Part no.: 257276 Flat seal ring Cu 6.2x17.5x2.0
More informationFLOWave SAW-Flowmeter
SAW-Flowmeter No parts in the measurement tube 28-04 Conform to hygienic requirements Ideal for low conductivity or non conductive liquids Digital communication Type 8098 can be combined with... Compact,
More informationMagnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up
Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically
More informationBDD-UM 3023 Digital Display
BDD-UM 3023 Digital Display for analogue input signals instruction manual Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.f. Germany Phone +49 (0) 71 58/1 73-0 Fax +49 (0) 71 58/50 10 Servicehotline
More informationInstallation & Operating Manual. iwap202
Installation & Operating Manual iwap202 This page is intentionally left blank. Document Number 409345 (based on 407655) (See Last Page for Revision Details) For warranty information, refer to Terms and
More informationMagnetic Inductive Flow Sensors VMI Series
Magnetic Inductive Flow Sensors VMI Series SIKA Dr.Siebert & Kühn GmbH & Co. KG Struthweg 7 9 34260 Kaufungen Germany.: +49 5605 803-0 Fax: +49 5605 803-54 e-mail: info@sika.net www.sika.net Magnetic Inductive
More informationParts List 4 MODEL T-18 and T-27 Mark II Turbo-Meters
MP-1070A Rev. 9 Invensys Energy Metering 80 Liberty Boulevard DuBois, PA 15801 Telephone (814) 371-8000 FAX (814) 375-8460 Parts List 4 Model T-18 and T-27 Mark II Turbo-Meter Parts List 4 MODEL T-18 and
More informationHeavy-Duty Gate Latch (Self-Latching)
Heavy-Duty Gate Latch (Self-Latching) Installation Instructions PLEASE READ OWNER'S MANUAL COMPLETELY BEFORE INSTALLING YOUR HINGE KIT. 5010EPN V1 4/14 Owner's Manual Version 1.0 For use with; aluminum
More informationRotary Encoder System Compact Model Range
we set the standards RIK Rotary Encoder System Compact Model Range 2 Incremental rotary encoder Features Compact design, consisting of scanning head with round cable, 15pin D-sub connector and grating
More informationOperating instructions Magnetic-inductive flow meter FMM FMM FMM
Operating instructions Magnetic-inductive flow meter FMM50-1002 FMM75-1002 FMM100-1002 Scan or Click the above QR Code or go to https://www.automationdirect.com/vid-fl-0003 for a short quick start video.
More informationKNX PY. Global Irradiance Sensor. Installation and Adjustment
EN KNX PY Global Irradiance Sensor Installation and Adjustment 1 Content 1. Description... 3 1.1. Scope of delivery... 3 1.2. Technical specifications... 3 2. Installation and commissioning... 4 2.1. Notes
More informationWARNING. Serial Number. BX Ford Taurus With Adaptive Cruise Control Installation Instructions
Serial Number BX2629 Please read BOTH these and the General Towing Instructions before attempting to install or operate this equipment. 1. Blue Ox towing products and accessories are intended to be installed
More informationScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system
pool/spa control system ScreenLogic Wireless Connection Kit Installation Guide P/N 520663 - Rev A 8 Technical Support Contact Technical Support at: Sanford, North Carolina (8 A.M. to 5 P.M.) Phone: (800)
More informationW 23-2: Focussing on what is essential and economic
Product group W - BGB Photoelectric proximity switch Energ. Photoelectric proximity switch W -: Focussing on what is essential and economic Photoelectric reflex switch The indicator LEDs on the W - offer
More informationDUST COLLECTOR 70 GALLON, 2 HP
DUST COLLECTOR 70 GALLON, 2 HP Model 45378 ASSEMBLY AND OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2001 by Harbor Freight
More informationWind Transmitter compact xx
THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021075/08/11 Wind Transmitter compact 4.3519.xx.140... 961 ADOLF THIES GmbH & Co. KG Hauptstraße 76
More informationROBOT KR 350. Installation, Connection, Exchange. Ro/Me/03/ en. 1of 26
ROBOT KR 350 Installation, Connection, Exchange 1of 26 e Copyright KUKA Roboter GmbH This documentation or excerpts therefrom may not be reproduced or disclosed to third parties without the express permission
More informationEolis io. Notice Instructions Anleitung Handleiding Manuale. Brugsanvisning Käyttöopas Bruksanvisning Veiledning FR EN DE NL IT DA FI SV NO
FR DE NL IT Notice Instructions Anleitung Handleiding Manuale DA FI SV NO Brugsanvisning Käyttöopas Bruksanvisning Veiledning TRANSLATED VERSION These instructions apply to all versions of, the different
More informationOperating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2018
Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 02 / 2018 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warning signs used...3 2 Safety
More informationHowtoPlans..org. 12'x20' Garden Shed Plan
HowtoPlans.org 12'x20' Garden Shed Plan Compare our Free vs. Premium Shed Plan This perfectly designed plan will guide you through the entire process of building your very own shed for any backyard or
More informationWind Direction Transmitter - compact - with serial output x0.x00
THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021450/11/05 Wind Direction Transmitter - compact - with serial output - 4.3129.x0.x00 ADOLF THIES
More informationElectronic Heating Energy Meters
5 333 SIEMECA Electronic Heating Energy Meters WFM... WFQ... Electronic, mains-independent meters to acquire heating energy consumption in autonomous heating and domestic hot water plants. Storage and
More informationinstallation instructions WC Frame 1180mm with Dual Flush Cistern
installation instructions WC Frame 1180mm with Dual Flush Cistern (C,D,E) K F/G N L M 12 13 14 16 1 2 11 A 5 6 Q O Y 3 C 10 E D B P,Z,AA R T V S 4 U 2 No. Part no. Description Quantity A WC Frame with
More informationWind Direction Transmitter - compact - with Poti Output xx.712
THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021434/06/06 Wind Direction Transmitter - compact - with Poti Output - 4.3129.xx.712 ADOLF THIES GmbH
More informationPhotoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems
WLL 0(T) Photoelectric switches Photoelectric switches with fibre-optic cable Proximity mode Photoelectric switches with fibre-optic cable Through-beam mode Photoelectric switches WLL 0(T), fibre-optic
More informationMini Encoder High Resolution
Mini Encoder High Resolution PWB encoders GmbH Am Goldberg 2 D-99817 Eisenach Germany Phone: +49 3691 72580-0 Fax: +49 3691 72580-29 info@pwb-encoders.com MEHR25 plug Rev.5A / 27.04.2017 info@pwb-encoders.com
More informationABM International, Inc. Navigator Assembly Manual
ABM International, Inc. 1 1.0: Parts List Tablet (Qty. 1) Tablet mount (Qty. 1) NOTE: Mount may appear and operate different then image below Control Box (Qty. 1) Motor Power Supply (Qty. 1) 2 X-axis motor
More informationCV Control Valves Installation and Operation Manual
CV00 - Control Valves Installation and Operation Manual Overview Warning: This bulletin should be used by experienced personnel as a guide to the installation of the Armstrong CV00 Control Valve. Selection
More informationModular transfer system. PDF- Catalog Modular Transfer System
Modular transfer system PDF- Catalog Modular Transfer System 1 Modular Transfer System TLM 1000 156, route de Lyon 38300 DOMARIN FRANCE Phone (33) 4 37 03 33 55 Fax (33) 4 37 03 33 59 September 2001 edition
More informationAssembly Instructions Beta Prusa Standard & Deluxe
Assembly Instructions Beta Prusa Standard & Deluxe 3D Printer Version 2.6 Date Page 1 / 67 General data about the assembly instructions for an incomplete machine according to appendix VI of the EG machinery