BDD-UM 3023 Digital Display

Size: px
Start display at page:

Download "BDD-UM 3023 Digital Display"

Transcription

1 BDD-UM 3023 Digital Display for analogue input signals instruction manual Balluff GmbH Schurwaldstrasse Neuhausen a.d.f. Germany Phone +49 (0) 71 58/ Fax +49 (0) 71 58/50 10 Servicehotline +49 (0) 7158/ balluff@balluff.de

2 Warranty For delivered products our "Allgemeine Lieferungs- und Zahlungsbedingungen" are effective. In no event we or our suppliers shall be liable for any other damages whatsoever (including, without limitation, damages for loss of business profits, business interruption or other pecuniary loss) arising out of or inability to use this product. All our products are warranted against defective material and workmanship for a period of two (2) years from date of delivery. If it is necessary to return the product to us, the sender is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. This warranty does not apply to defects resulting from action of the buyer, such mishandling, improper interfacing, operation outside of design limits, improper repair or unauthorized modification. Trademarks All trademarks they are named ore portrayed in the text are registered trademarks of its owner. The trademarks are recognized.

3 Contents 1. Discription Safety instructions Explanation of symbols Mounting Place of operation Panel mounting Panel for switch board Electrical connections General Instructions Hints against noisy enviroment Connection and pin assignment Connection of input signals Input voltage 0-10 V Input current 0-20 ma, 4-20 ma Connection of power supply voltage Start-Up Procedure of programming Tasten- und LED-Funktionen Programming Programming level for configuration

4 Scaling the display range Tare function Display test Programming quick reference Technical specifications Notices Stand : UM3023C.PUB Technische Änderungen vorbehalten 3

5 1. Discription 1. Discription The digital panel meter model UM 3023 is an universal instrument for measuring analog input signals listed below: Voltage 0-10 V Current 0-20 ma / 4-20 ma Standard Hardware 4 function buttons on the frontside Standard Software Scaling Taring Free setting of decimal point Display test 2. Safety instructions When delivered the intrument has been tested to meet all functions described. Before installing the instrument please read the mounting and servicing instructions. We have no liability or responsibility to customer or any other person or entity with respect to any liablity, loss or damage caused or alleged to be caused directly or indirectly by equipment or software sold or furnished by us. Read the installation instruction carefully. No liability will be assumed for any damage caused by improper installation. Inspect the instrument module carton for obvious damage. Be shure there are no shipping and handling damages on the module before processing. Do not apply power to the instrument if it has damages. The warranty does not apply to defects resulting from action of buyer, such as mishandling, improper interfacing, operation outside of design limits, improper repair or unauthorized modifications. 4

6 3. Mounting 2.1. Explanation of symbols Caution Attention Instruction Hint Caution: Attention: Instruction: Hint: Dangerous! Will cause damage If not noticed, trouble may occur. Useful hints for better operation. 3. Mounting 3.1. Place of operation Attention must be payed to the protection against humidity, dust and high temperatures at the place of operation Panel mounting Panel for switch board For mounting in switch boards, insert the case into the panel cutout (92,0 +0,8 x 45,0 +0,6 mm) from the front, using a fresh gasket for sealing as required. Click into and place at each side the two fastening clips (M2,5 x 50 mm). Tighten the screws alternately, using enough pressure to get good retention and sealing at the panel. 5

7 4. Electrical connections 48,0 P 42,0 96,0 45,0 +0,6 Panel cutout 89,6 92,0 +0,8 15,0 55, Electrical connections 4.1. General Instructions It is forbidden to plug or unplug connectors with voltage applied Attach input and output wires to the connectors only without voltages applied Cords must be provided with sleeves Attention must be paid that the power supply voltage applied will agree with voltage noticed at the Type plate. The instrument has no power-on switch, so it will be in operation as soon as the power is connected. 6

8 4. Electrical connections 4.2. Hints against noisy enviroment All inputs and outputs are protected against noisy environment and high voltage spikes. Nevertheless the location should be selected to ensure that no capacitive or inductive interference can have an effect on the instrument or the connection lines. It is advisable: To use shielded cables. The wiring of shields and ground (0V) should be star-shaped. The distance to interference sources should be as long as possible. If necessary, protective screen or metal enclosures must be provided. Coils of relays must be supplied with filters. Parallel wiring of input signals and AC power lines should be avoided Connection and pin assignment All inputs and outputs are connectors designed as plug-in screw terminals

9 4. Electrical connections Pin assignment: 1 Signal input voltage 4 ground 2 Signal input current 5 Supply voltage (-) 3 Signal ground 6 Supply voltage (+) 4.4. Connection of input signals Input voltage 0-10 V : 10 V 3: 0 V Inputcurrent0-20mA,4-20mA : + 0/4-20 ma 3: Connection of power supply voltage DC-supply V/DC : earth 5:GND 6: V/DC 8

10 5. Start-Up 5. Start-Up Attention must be paid that the power supply voltage applied will agree with the voltage noticed at the type plate. Switch the power supply on (supply voltage applied to 5 (-) and 6 (+)). When delivered, the instrument is programmed with a standard configuration (default configuration). According to his measuring task, the customer can change the standard configuration by programming. Attention: When the instrument is built-in a machine and the customer wants to change the configuration, attention must be paid, that no damage will occur to the machine! 6. Procedure of programming The procedure of programming is organized in different steps and can be carried out via the push buttons on the front of the instrument Function of buttons and LEDs 4-decade display LED 2 LED 1 mm Insertion shield for dimensions Programming button Select the display decade/ Tare Decreasing values Increasing values 9

11 7. Programming LED1 LED2 Description green/flashes dark lights yellow-orange The displayed value is not tared The displayed value is tared Programming mode is activated 7. Programming The operation and the programming of the panel meter is organized in several programming levels. Programming is performed by the buttons on the front. Push button P -button + -button - -button * -button Selection of - parameter Function Increase of - number of parameter - parameter Decrease of - number of parameter - parameter select the display decade in the programming mode / tare button Entering the programming routine Press P -button together with + -button The display shows 0-00" Leaving the programming routine Press + -button or - -button until the display shows 0End Confirm the display 0End by pressing the P -button 10

12 7. Programming Selection of a parameter select the parameter by pressing + -button oder - -button Confirm the parameter by pressing the P -button. The display shows the last programmed value of the selected parameter Change and confirm a selected parameter Change the parameter by pressing the + -button or the - -button Select the display decade to be changed by pressing the * -button Confirm the parameter by pressing the P -button The display shows the programming level and the number of the parameter e.g.: 0-04" => parameter Programming level for configuration 0-00 Param. Description Range 0-00 Input range 0 -> Voltage 0 bis 10 V 1 -> Current 0 bis 20 ma 2 -> Current 4 bis 20 ma Default Value Display value of min. input signal Display value of max. input signal Decimal point 0 -> XXXX 1 -> XXX.X 2 -> XX.XX 3 -> X.XXX Tare on = 1, off = End Leaving programming level

13 7. Programming Scaling the display range Over- and underflows are displayed as follows: An overflow is displayed as nnnn; this occurs if: the input signal exceeds the permissible maximum around more than 0,5V or 1mA; e.g. input voltage >10,5 V or input current >21 ma. the display range exceeds the possible maximum. (> 9999) An underflow is displayed as uuuu; this occurs if: the input signal exceeds the permissible minimum around more than 0,5V or 1mA; e.g. input voltage < -0,5V or input current < -1mA or 3mA. the display range exceeds the possible minimum. (< -999) the parameter P0-03 has the value 3 (decimal point after the first decade: X.XXX) (in this case is the display of negative values is not possible) and the displayed value would be below The display values for the minimum and the maximum input signal is set in the parameters 0-01 and Display value Overflow Parameter 0-02 Example: Input range 0 bis +10 V, Display range: -999 bis Step Param. Value End End -0, ,5 Parameter Input voltage [V] 0-01 Underflow 12

14 7. Programming 7.2. Tare function The tare function works as follows: pushing the tare button will store the displayed value in the tare memory. The tare value will be substracted from the measured value. The tare value is stored in an non-volatile memory and will be saved even when the device is switched off. Activating the tare function: push the * -button (Parameter 0-04 had to be set to 1) Erase the tare value: push the * -button for ca. 3 seconds. After this reset the untared value is displayed Display test Activating the display test will drive all segments of the display. The display shows during the test. Activating the display test push the P -button 7.4. Programming quick reference 3 Measurement mode - 2 "P" und "+" P input range + - P Display value of 0-01 minimum signal value P Display value of maximum signal value + P Programmable 0-03 decimal points P Tare + 0End + P

15 8. Technical specifications 8. Technical specifications Analog input Resolution Input ranges voltage impedance current impedance Conversion rate Display Operation, keyboard design Power supply power consumption : 12 Bit : 0 to 10 V, ± 0,05 %, ± 1 Digit : > 50 kω : 0/4 to 20 ma, ± 0,05 %, ± 1 Digit :10 Ω : 5 measurements/s : 4 decades, 14 mm, red : decimal point programmable : preliminary zero suppression : - sign at negative Values : front membrane with push buttons : 24 V, ± 20 % DC (isolated) : max. 65 ma Case : 96 x 48 x 60 mm depth : < 72 mm (incl. screw terminal) protection case, at the front : IP 54 protection case, connection : IP 20 EMV : in conform with 89/336/EWG Operating temperature : 0 to 60 C Storage temperature : -20 to 70 C Humidity : < 80 %, not-condensing Field of application : class 2 : overvoltage protection II Weigth : approx. 200 g 14

16 9. Notices 9. Notices 15

17 9. Notices 16

18 17 9. Notices

19

20

Instruction Manual Inductive Gauging Sensor

Instruction Manual Inductive Gauging Sensor Instruction Manual Inductive Gauging Sensor EX-200 Series 96M0367 CONTENTS Page Part names and functions...3 Connections/Hints on correct use... 4 Installations... 5 Adjustment... 6 Specifications... 7

More information

CM 3001 Digital Panel Meter. Universal Counter/Frequency- and Time Meter. Instruction Manual ERMA. Electronic GmbH

CM 3001 Digital Panel Meter. Universal Counter/Frequency- and Time Meter. Instruction Manual ERMA. Electronic GmbH CM 3001 Digital anel Meter Universal Counter/Frequency and Time Meter Instruction Manual ERMA Electronic GmbH Warranty For delivered products our "Allgemeine Lieferungs und Zahlungsbedingungen" are effective.

More information

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5 SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5 Phone: (905) 564-0801 Fax: (905) 564-0806 www.telecor.com E:\T2-108\T2-M108-ABC\T2-M108-B.doc/AD

More information

User s Guide. 400A AC/DC Clamp Meter. Model MA220

User s Guide. 400A AC/DC Clamp Meter. Model MA220 User s Guide 400A AC/DC Clamp Meter Model MA220 Introduction Thank you for selecting the Extech MA200 AC/DC Clamp Meter. This meter measures AC/DC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,

More information

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph User Guide AC/DC Mini Clamp Meter Model 380941 Large 3 3/4 digit LCD display with 40 segment bargraph Continuity and Frequency Measurements One touch DCA zero adjust MIN/MAX and Data Hold functions 0.9

More information

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information Latching Relay CSM DS_E Compact Mechanical Lock Latching Relays with Manual Buttons Compact design with a height of 7 mm, width of. mm, and depth of 8. mm. Plus, one Relay only weighs 7 g. Quick set and

More information

User s Guide. Model MA A AC Mini Clamp-on Meter

User s Guide. Model MA A AC Mini Clamp-on Meter User s Guide Model MA150 200A AC Mini Clamp-on Meter Introduction Congratulations on your purchase of Extech s MA150 AC Mini Clamp Meter. This meter is shipped fully tested and calibrated and, with proper

More information

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free 2001A 200KHz Function Generator Instruction Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com WARRANTY Global Specialties

More information

Autoranging Multimeter Extech EX503

Autoranging Multimeter Extech EX503 User's Guide Autoranging Multimeter Extech EX503 Introduction Congratulations on your purchase of the Extech EX503 Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current, Resistance,

More information

Dawson DDM190. Digital Multimeter User s Manual

Dawson DDM190. Digital Multimeter User s Manual Dawson DDM190 Digital Multimeter User s Manual TABLE OF CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories.. Error! Bookmark not defined. Safety Information... 7

More information

Process displays For standard signals, temperature, resistance measurement

Process displays For standard signals, temperature, resistance measurement Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions

More information

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE Digital Panel Meter K3TE Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. Highly visible display with

More information

Pen Multimeter. Model

Pen Multimeter. Model Pen Multimeter Model 381626 CAUTION: Read, understand and follow all Safety Rules and Operating Instructions in this manual before using this product. This instrument is a 3200 count pen style digital

More information

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc. User s Guide RP5600 Passive Probe July 2010 RIGOL Technologies, Inc. Guaranty and Declaration Copyright 2010 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information RIGOL is a registered trademark

More information

WiMo Antennen und Elektronik GmbH Am Gäxwald 14, D Herxheim Tel. (07276) FAX 6978

WiMo Antennen und Elektronik GmbH Am Gäxwald 14, D Herxheim Tel. (07276) FAX 6978 2m DISCOVERY LINEAR AMPLIFIER (GS 31) Operating Manual WiMo Antennen und Elektronik GmbH Am Gäxwald 14, D-76863 Herxheim Tel. (07276) 96680 FAX 6978 http://www.wimo.com e-mail: info@wimo.com INDEX 1. Specifications

More information

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION & OPERATING INSTRUCTIONS INSTALLATION & OPERATING INSTRUCTIONS IM-450 Models 153 Programmable Step Attenuator This documentation may not be reproduced in any form, for any purpose unless authorized in writing by API / Weinschel,

More information

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual Dawson DDM181 Pocket-Size Autorange Digital Meter User s Manual 1 Table of Contents LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories... 4 Important Safety Information...

More information

Table of Contents 9.0 WARRANTY. 1.0 Introduction Package Contents. 2.0 Safety Instructions Overview...003

Table of Contents 9.0 WARRANTY. 1.0 Introduction Package Contents. 2.0 Safety Instructions Overview...003 9.0 WARRANTY Table of Contents ELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the original purchaser that this product is of merchantable quality and confirms in kind and quality with the

More information

FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL

FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL 20020628 CONTENTS DESCRIPTION... 3 OPERATION... 4 Power Supply...4 Output Range...4 Temperature Operating Range and Temperature Limits...4

More information

Thermocouple - Transducer

Thermocouple - Transducer Thermocouple - Transducer TM3 Characteristics: Thermocouple type J, K, R, S, T, E, B, N Linearity error < 1% Measurement range configurable -210...+1820 C Built-in cold junction compensation Galvanic 3-way

More information

USER MANUAL. MODEL 457B Seven Port Active Twinax Star Hub. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 457B Seven Port Active Twinax Star Hub. SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 457B Seven Port Active Twinax Star Hub An ISO-9001 Certified Company Part #07M457B-C Doc. #069011UC Revised 4/22/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com

More information

Pen Multimeter. Model

Pen Multimeter. Model Pen Multimeter Model 381626 CAUTION: Read, understand and follow all Safety Rules and Operating Instructions in this manual before using this product. This instrument is a 3200 count pen style digital

More information

Trident Laundry Chemical Delivery System

Trident Laundry Chemical Delivery System Trident Laundry Chemical Delivery System Installation and Setup Guide The DEMA Trident is a complete laundry chemical delivery system for commercial laundry applications. The Trident features Bluetooth

More information

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Ordering Information. Stepping Relay Unit G9B. Model Number Legend Stepping Relay Unit CSM DS_E_4_1 Ideal for Controlling Pumps and Production Lines with Six or Twelve Stepping Circuits Built-in relays switch 2 A at 250 VAC or 30 VDC. Initialization of stepping with reset

More information

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

TL-W5MD1 2M *1 *3 TL-W5MD2 2M Flat Inductive CSM DS_E_9_ Standard Flat s in Many Different Variations Only mm thick yet provides a sensing distance of mm (MC). Aluminum die-cast models also available. Be sure to read Safety Precautions

More information

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter User s Manual MiniTec TM Series Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter Introduction Congratulations on your purchase of Extech s MN26 Autoranging Multimeter. This

More information

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130 User s Guide MultiView Series Digital MultiMeters Models: MV110 MV120 MV130 WARRANTY EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year

More information

PHV RO High Voltage Passive Probe. Instruction Manual

PHV RO High Voltage Passive Probe. Instruction Manual PHV 1000-3-RO High Voltage Passive Probe Instruction Manual Copyright 2012 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

Digi-Stop. User Manual for: Digi-Stop. Digital Readout Firmware version d & Higher

Digi-Stop. User Manual for: Digi-Stop. Digital Readout Firmware version d & Higher Digi-Stop User Manual for: Digi-Stop Digital Readout Firmware version d 2.000 & Higher Warranty Accurate Technology, Inc., warrants this product against defective parts and workmanship for 1 year commencing

More information

Out 1 sin / cos 1Vpp. sin / cos 1Vpp. Out 3. sin / cos 1Vpp. Out 4 sin / cos 1Vpp. Interface type SV211 SinCos signal splitter with 4 SinCos outputs

Out 1 sin / cos 1Vpp. sin / cos 1Vpp. Out 3. sin / cos 1Vpp. Out 4 sin / cos 1Vpp. Interface type SV211 SinCos signal splitter with 4 SinCos outputs Operating Manual Out 1 sin / cos 1Vpp Input: sin / cos 1 Vpp Out 2 sin / cos 1Vpp Out 3 sin / cos 1Vpp SV 211 Out 4 sin / cos 1Vpp Interface type SV211 SinCos signal splitter with 4 SinCos outputs Product

More information

OPERATOR S MANUAL Model 58B Prefeed / Dereeler

OPERATOR S MANUAL Model 58B Prefeed / Dereeler 110 Fairgrounds Drive P.O. Box 188 Manlius, NY 13104-0188 USA 315.682.9176 FAX: 315.682.9160 OPERATOR S MANUAL Model 58B Prefeed / Dereeler PRODUCTION WIRE PROCESSING EQUIPMENT Website: www.carpentermfg.com

More information

TETRIS 1000 High Impedance Active Probe. Instruction Manual

TETRIS 1000 High Impedance Active Probe. Instruction Manual TETRIS 1000 High Impedance Active Probe Instruction Manual Copyright 2015 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

Digital Indicator DS 96/48 PK

Digital Indicator DS 96/48 PK Data Sheet 10/33-2.1-EN Digital Indicator DS 9/48 P Digital Indicator DS 9/48 PK Inputs Direct current, direct voltage Thermocouple Resistance thermometer Programmable via front keys or PC software Limit

More information

INSTRUCTION MANUAL. MODEL: Vintage 60R. Vintage Series Guitar Amplifi er

INSTRUCTION MANUAL. MODEL: Vintage 60R. Vintage Series Guitar Amplifi er INSTRUCTION MANUAL MODEL: Vintage 60R Vintage Series Guitar Amplifi er 2 INTRODUCTION Thank you for choosing this Johnson amplifier. Please read this manual carefully and completely before operating your

More information

Model MV106J/MV116J. ±10nVdc to ±11Vdc Precision DC Voltage Standard Source. Operating Manual

Model MV106J/MV116J. ±10nVdc to ±11Vdc Precision DC Voltage Standard Source. Operating Manual Model MV106J/MV116J ±10nVdc to ±11Vdc Precision DC Voltage Standard Source Operating Manual This page intentionally left blank. MV 106 & MV116 OPERATORS MANUAL Serial No. Win-man\mvman.wpd This page intentionally

More information

All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting

All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting Data Sheet 10/86-2.36-EN All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting Compact robust power relay Type RH(M) 1003: 3 changeover contacts Type RH(M) 1004: 4

More information

Digi-Stop. Installation & Operation

Digi-Stop. Installation & Operation Digi-Stop Installation & Operation WARRANTY Accurate Technology, Inc. warrants the ProScale Systems against defective parts and workmanship for 1 year commencing from the date of original purchase. Upon

More information

DM-46 Instruction Manual

DM-46 Instruction Manual Auto Meter Products Inc. Test Equipment DM-46 Instruction Manual Automotive Multimeter and Inductive Amp Probe The DM-46 is the auto industry s answer to pocket portability in a 20 2650-1552-00 3/8/11

More information

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals Accessories Highquality digital indicator for panel mounting Model DI35M, with multifunction input Model DI35D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building

More information

CHECK LINE INSTRUMENTS. ! Tolerates a wide variation of voltages. ! Immune to electrically noisy environments.

CHECK LINE INSTRUMENTS. ! Tolerates a wide variation of voltages. ! Immune to electrically noisy environments. Panel Mount Tachometer Model DT-5TG (VDC) CHECK LINE INSTRUMENTS ELECTROMATIC E Q U I P M E N T C O., I N C. 600 Oakland Ave., Cedarhurst, NY 11516 U.S.A. TEL: 516-295-4300 FAX: 516-295-4399 Instruction

More information

Instruction Manual Model M Switch, DPDT, Manual Select

Instruction Manual Model M Switch, DPDT, Manual Select Instruction Manual Model 1582-70M Switch, DPDT, Manual Select November 2018 Rev 0 STATUS MODEL 1582 CROSS TECHNOLOGIES INC. MANUAL SELECT POWER Data, drawings, and other material contained herein are proprietary

More information

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est.

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est. DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif. 95005 831-336-8891 Fax 831-336-3840 http://www.dyneng.com sales@dyneng.com Est. 1988 User Manual PIM-Parallel-IO PMC IO Module for PMC Parallel IO PIM

More information

SCHMIDT. VibroSens 401. Operating Instructions

SCHMIDT. VibroSens 401. Operating Instructions SCHMIDT VibroSens 401 Operating Instructions SCHMIDT Vibration Control VibroSens 401 Operating Instructions 1 Important information... 3 2 Use... 4 3 Description of functions... 5 4 Installation... 10

More information

DDM350 Pen-Type Digital Multimeter User s Manual

DDM350 Pen-Type Digital Multimeter User s Manual DDM350 Pen-Type Digital Multimeter User s Manual CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY....1 Out of the Box...1 Accessories......2 Safety Information...2 Safety Symbols...3 Certification......4

More information

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter User Manual UNICOM 2500 Installation Operation Programming Universal Communication Converter UNICOM 2500 Electro Industries/GaugeTech 1800 Shames Drive Westbury, New York 11590 Tel 516.334.0870 Fax 516.338.4741

More information

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL Roline L1 Series Humidity - Temperature Transmitters INSTRUCTION MANUAL 20030314 CONTENTS Overview... 3 Operation... 5 Power supply... 5 Operating range and limits... 5 Temperature compensation of the

More information

model 101 single channel microphone preamplifier owner s manual Rev C

model 101 single channel microphone preamplifier owner s manual Rev C 2434 30th street, boulder, CO 80306-0204 USA tel 303.443.7454 fax 303.444.4634 info@gracedesign.com / www.gracedesign.com single channel microphone preamplifier Rev C all contents Grace Design/ Lunatec

More information

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

PHV 1000-RO High Voltage Passive Probe. Instruction Manual PHV 1000-RO High Voltage Passive Probe Instruction Manual Copyright 2014 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

Documentation. Content. Measurement and Control. Type: ELT-GP1. 1. Installation instructions 2. Data sheets 3. Declarations of conformity

Documentation. Content. Measurement and Control. Type: ELT-GP1. 1. Installation instructions 2. Data sheets 3. Declarations of conformity Documentation Measurement and Control Type: ELT-GP1 Content 1. Installation instructions 2. Data sheets 3. Declarations of conformity (Part No. 008Q520) eltherm GmbH Ernst-Heinkel-Str. 6-10 57299 Burbach

More information

Amplifier Series BASIC. Installation & Operations Manual

Amplifier Series BASIC. Installation & Operations Manual Amplifier Series BASIC Installation & Operations Manual Bittner-Audio 200 Power Amplifier Series BASIC Bittner - Audio September 200 200 Bittner-Audio. All Rights Reserved. Bittner-Audio reserves specification

More information

Signal Isolation Module. Instruction Manual SIM

Signal Isolation Module. Instruction Manual SIM Signal Isolation Module Instruction Manual SIM200-000 Table of Contents 1. General Description... 3 2. Specifications... 3 2.1 Electrical... 3 2.2 Physical... 4 3. Installation... 4 3.1 Wiring Guidelines...

More information

+GF+ SIGNET Temperature Transmitter Instructions

+GF+ SIGNET Temperature Transmitter Instructions GF SIGNET 80- Temperature Transmitter Instructions ENGLISH -80.090- B-/00 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal

More information

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL M1 Series Humidity - Temperature Transmitter INSTRUCTION MANUAL 20031110 -2- CONTENTS Overview... 3 Operation... 4 Power supply... 4 Operating range and limits... 4 Temperature compensation of the humidity

More information

TETRIS User's Guide. High Impedance Active Probe DO177-1

TETRIS User's Guide. High Impedance Active Probe DO177-1 TETRIS 1500 High Impedance Active Probe User's Guide DO177-1 TETRIS 1500 Copyright 2010 Ltd. All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

VideoEase VGA 1x4 Distribution Hub (500150, ) Installation Guide

VideoEase VGA 1x4 Distribution Hub (500150, ) Installation Guide VideoEase VGA 1x4 Distribution Hub (500150, 500151) Installation Guide P/N: 94-000624-A SE-000605-A Table of Contents 1. Overview...3 1.1. Description...3 1.2. Features...4 2. Technical Specifications...5

More information

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control Gain Electronic Co. Ltd. Table Of Contents Safety Considerations ------------------------------------------------------------2

More information

ITP14. Universal process indicator. User guide

ITP14. Universal process indicator. User guide ITP14 Universal process indicator User guide ITP14_2018.05_0279_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Germany Tel.: +49 (0)

More information

Radio Remote Controls Manual K Series

Radio Remote Controls Manual K Series Radio Remote Controls Manual K Series PN 52764 2010.12.20 Rev. 2 K Series radio control manual 1 Conductix Incorporated The technical data and images which appear in this manual are for informational purposes

More information

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz Page 1 of 10 INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK Model LI-4100 10 khz to 10 MHz Page 2 of 10 Table of Contents 1.0 Introduction... 3 2.0 Product Description... 4 3.0 Product Specifications...

More information

SUBNANOSECOND PULSE GENERATOR PPG-2/1000 USER MANUAL

SUBNANOSECOND PULSE GENERATOR PPG-2/1000 USER MANUAL SUBNANOSECOND PULSE GENERATOR PPG-2/1000 USER MANUAL 2015 Megaimpulse Ltd. Copyright 2015 MEGAIMPULSE Ltd. All Rights Reserved. MEGAIMPULSE LTD. PROVIDES THIS MANUAL "AS IS" WITHOUT WARRANTY OF ANY KIND,

More information

200Amp AC Clamp Meter + NCV Model MA250

200Amp AC Clamp Meter + NCV Model MA250 User's Guide 200Amp AC Clamp Meter + NCV Model MA250 Introduction Congratulations on your purchase of this Extech MA250 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance,

More information

Operating Instruction

Operating Instruction Level and Pressure Operating Instruction VEGASEL 643 6 5 + + 3 5 + + max. min. on VEGASEL 643 5 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 1 Product description 1.1 Function

More information

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330 User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330 Introduction Congratulations on your purchase of the Extech EX330 Meter. The EX330 offers AC/DC Voltage, AC/DC Current,

More information

1800 Series Attachable Loop-Powered Digital Indicators Operating Manual

1800 Series Attachable Loop-Powered Digital Indicators Operating Manual 1800 Series Attachable Loop-Powered Digital Indicators Operating Manual 1010 West Bagley Road, Berea, Ohio 44017 P 440.243.0888 F 440.243.3472 www.noshok.com Index 1 INTRODUCTION 3 2 SAFETY REGULATIONS

More information

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 2017A RS-232 to 20ma Current Loop Converter Part# 07M2017A-A Doc# 073021UA Revised 10/15/93 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com 1.0 WARRANTY

More information

Digi-Fence. User Manual for: Digi-Fence (all models) Digital Readout Firmware version d & Higher

Digi-Fence. User Manual for: Digi-Fence (all models) Digital Readout Firmware version d & Higher Digi-Fence User Manual for: Digi-Fence (all models) Digital Readout Firmware version d 2.000 & Higher Warranty Accurate Technology, Inc., warrants this product against defective parts and workmanship for

More information

User s Guide. RP7000 Series Active Probe. Dec RIGOL Technologies, Inc.

User s Guide. RP7000 Series Active Probe. Dec RIGOL Technologies, Inc. User s Guide RP7000 Series Active Probe Dec. 2012 RIGOL Technologies, Inc. Guaranty and Declaration Copyright 2011 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information RIGOL is a registered

More information

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE OPERATION & SERVICE MANUAL FOR FC 100 SERIES AC POWER SOURCE FC 110 AC POWER SOURCE VERSION 1.3, April 2001. copyright reserved. DWG No. FC00001 TABLE OF CONTENTS CHAPTER 1 INTRODUCTION... 1 1.1 GENERAL...

More information

Distance Sensors BOD 26K.... with optional Master-Slave-Mode

Distance Sensors BOD 26K.... with optional Master-Slave-Mode Distance... with optional Master-Slave-Mode Laser Distance The Balluff distance sensor not only detects the presence of objects, but can also indicate their precise position or location. This means the

More information

USER'S MANUAL DMR-6700

USER'S MANUAL DMR-6700 USER'S MANUAL Multimeter True RMS DMR-6700 CIRCUIT-TEST ELECTRONICS www.circuittest.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

Earth Fault Indicator EFI-BLZ-50 User Manual

Earth Fault Indicator EFI-BLZ-50 User Manual Earth Fault Indicator EFI-BLZ-50 User Manual CONTENTS SAFETY NOTICE.................................................................................... 3 1 OVERVIEW......................................................................................

More information

Model 9305 Fast Preamplifier Operating and Service Manual

Model 9305 Fast Preamplifier Operating and Service Manual Model 9305 Fast Preamplifier Operating and Service Manual This manual applies to instruments marked Rev 03" on rear panel. Printed in U.S.A. ORTEC Part No.605540 1202 Manual Revision B Advanced Measurement

More information

AMP SELECTOR Owner s Manual

AMP SELECTOR Owner s Manual AMP SELECTOR Owner s Manual Version 1.0 VOODOO LAB AMP SELECTOR User s Manual Introduction The Voodoo Lab Amp Selector is the ultimate stand-alone tool for switching your guitar into multiple amplifiers.

More information

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est.

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est. DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif. 95005 831-336-8891 Fax 831-336-3840 http://www.dyneng.com sales@dyneng.com Est. 1988 User Manual PIM-Universal-IO PMC IO Module PIM w/ SCSI II Bezel

More information

INSTRUCTION MANUAL. IBRit - rf1 - usb PC - Station for wireless Data transmission. M e s s t e c h n i k. Messtechnik GmbH & Co.

INSTRUCTION MANUAL. IBRit - rf1 - usb PC - Station for wireless Data transmission. M e s s t e c h n i k. Messtechnik GmbH & Co. M e s s t e c h n i k INSTRUCTION MANUAL PC - Station for wireless Data transmission Document No. : D1F604 001 Version : April 2006 Copyright : IBR Messtechnik GmbH & Co. KG Contents 1. Introduction 1.1

More information

Worldwide Manufacturer of Gas Detection Solutions. Transmitter EC 23. Operation Manual

Worldwide Manufacturer of Gas Detection Solutions. Transmitter EC 23. Operation Manual Worldwide Manufacturer of Gas Detection Solutions Transmitter EC 23 Operation Manual Table of Contents For Your Safety...4 General Description...4 Electrical Connections...5 Zero Point Adjustment...5

More information

Screens INTRODUCTION OPERATION. Quadrature Counting

Screens INTRODUCTION OPERATION. Quadrature Counting INTRODUCTION Your 5330X-403 is a counter with an eight-digit LCD display. A programmable scaler and decimal point allow for display in any engineering unit. Front View Screens There are four program-mode

More information

CURRENT MEARUREMENT SHUNT CS-10/500 USER MANUAL

CURRENT MEARUREMENT SHUNT CS-10/500 USER MANUAL CURRENT MEARUREMENT SHUNT CS-10/500 USER MANUAL 2017 Megaimpulse Ltd. Copyright 2017 MEGAIMPULSE Ltd. All Rights Reserved. MEGAIMPULSE LTD. PROVIDES THIS MANUAL "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER

More information

LT3000 ULTRASONIC LEVEL TRANSMITTER

LT3000 ULTRASONIC LEVEL TRANSMITTER LT3000 ULTRASONIC LEVEL TRANSMITTER Owner s Manual Specifications Installation Calibration Troubleshooting Warranty Drawings Distributed By: iprocessmart.com 14262 Doolittle Drive San Leandro, CA 94577

More information

Analog amplifier RA. RE Edition: Replaces:

Analog amplifier RA. RE Edition: Replaces: Analog amplifier RA RE 950 Edition: 08.05 Replaces: 0.006 For control of simple functions of electrohydraulic components Two power outputs (PWM) and one switching output Each output has a separately adjustable

More information

Series 7000 Torque Sensor for PTO-shafts

Series 7000 Torque Sensor for PTO-shafts Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Special for PTO shafts 1 ¾ und 1 3/8 Plug & Play solution, no additional

More information

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection Relays 22 Technical Data...1 Specifications...2 Model Number Structure - Relays...3 Model Number Selection... 4-5 Electrical Characteristics...6 Accessories...7 Dimensions...8 Instructions...10 Safety

More information

Instruction Sheet D-CPU. Secure CPU Holder

Instruction Sheet D-CPU. Secure CPU Holder Instruction Sheet D-CPU Secure CPU Holder I-00457 Rev A PARTS LIST NOTE: Select Security Components when a more secure application is desired. Mounting Track with Mounting Tape Security Bracket Assembly

More information

ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL

ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL ESP Product Warranty Zener Electric warrant the Electronic Shear Pin against defective workmanship and materials for a period of 24 months from the

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree of protection

More information

Magnetic, Incremental - Length Measuring System. Only functional with an ELGO MB R magnetic tape!

Magnetic, Incremental - Length Measuring System. Only functional with an ELGO MB R magnetic tape! GMIX1A Series Magnetic, Incremental - Length Measuring System 5 different adjustable resolutions between 0.1 and 0.01 mm s (at 4 edge triggering) repeat accuracy +/- 1 increment 5V-TTL or 10...30 V Push/Pull

More information

True RMS AC / DC Power Clamp Meter Model

True RMS AC / DC Power Clamp Meter Model User's Guide True RMS AC / DC Power Clamp Meter Model 380940 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment

More information

Model Number Structure

Model Number Structure Single-phase Voltage Relay CSM DS_E_3_1 Ideal for voltage monitoring for industrial facilities and equipment. Monitor for overvoltages or undervoltages. Manual resetting and automatically resetting supported

More information

UniStream Uni-I/O Modules

UniStream Uni-I/O Modules UniStream Uni-I/O Modules Technical Specifications UIS-WCB1 This guide provides specifications for Unitronics Uni-I/O Wide module UIS-WCB1. This module comprises: 10 Digital inputs, 24VDC, sink/source,

More information

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend Ratchet Relay CSM OEE_DS_E_1_1 Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation Each contact in the double-pole contact mechanism performs alternate make-brake operation

More information

DM-46 Instruction Manual

DM-46 Instruction Manual Test Equipment Auto Meter Products Inc. 413 West Elm Street Sycamore, IL 60178 Service (815) 899-0801 Toll Free (866) 883-TEST (8378) www.autometer.com/test DM-46 Instruction Manual Automotive Multimeter

More information

Pre-wired Photomicrosensor with Amplifier and Cable EE-SPW321/421 Compact, Thin-profile Photomicrosensor with special amplifier.

Pre-wired Photomicrosensor with Amplifier and Cable EE-SPW321/421 Compact, Thin-profile Photomicrosensor with special amplifier. Pre-wired Photomicrosensor with Amplifier and Cable CSM_EE-SPW1_41_DS_E_5_ Compact, Thin-profile Photomicrosensor with special amplifier. Slim amplifier ( 7.5 1 mm) can be handled like a cable. Provided

More information

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information *09005137* BA_EN_DE50 Rev.A 11/12 *09005137* d e v e l o p i n g s o l u t i o n s DE50 Operating Manual Differential pressure transmitter Table of Contents 1 Safety guidelines 2 Application purpose 3

More information

LOGIC MODULE 3 INPUT AND/OR INSTRUCTION MANUAL MODEL# POWER INPUT: +12 volts DC LOGIC INPUT: +12 volts DC or Ground 3 YEAR WARRANTY

LOGIC MODULE 3 INPUT AND/OR INSTRUCTION MANUAL MODEL# POWER INPUT: +12 volts DC LOGIC INPUT: +12 volts DC or Ground 3 YEAR WARRANTY INSTRUCTION MANUAL FILE: 09-58 DATE: 0-2-04 LOGIC MODULE 3 INPUT / MODEL# 09-58 POWER INPUT: +2 volts DC LOGIC INPUT: +2 volts DC or Ground 3 YEAR WARRANTY INTRODUCTION The 09-58 is a logic module that

More information

COUPLING DECOUPLING NETWORK MODEL CDN-AF4

COUPLING DECOUPLING NETWORK MODEL CDN-AF4 COUPLING DECOUPLING NETWORK MODEL CDN-AF4 II Warranty Com-Power warrants to its Customers that the products it manufactures will be free from defects in materials and workmanship for a period of 2 years.

More information

CURRENT. User Guide ACCESSORIES. External Sensor DT139. for MicroLog EC600 and EC mA ±0.1mA ±3% (before calibration)

CURRENT. User Guide ACCESSORIES. External Sensor DT139. for MicroLog EC600 and EC mA ±0.1mA ±3% (before calibration) External Sensor CURRENT DT139 Range: Resolution: Accuracy: Input impedance: Calibration: OV protection: 0-20mA ±0.1mA ±3% (before calibration) ~170Ω 2 calibration points ±55mA ACCESSORIES User Guide for

More information

User s Guide HX94B SERIES. Temperature/Relative Humidity Transmitter. Shop online at omega.com SM

User s Guide HX94B SERIES. Temperature/Relative Humidity Transmitter. Shop online at omega.com SM User s Guide Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info HX94B SERIES Temperature/Relative Humidity Transmitter omega.com info@omega.com Servicing

More information

AUTOMATION. Operator s Manual. ACF-10 Series Acoustical Flow Sensor for Solids. Rev. 1a, 2/03

AUTOMATION. Operator s Manual. ACF-10 Series Acoustical Flow Sensor for Solids. Rev. 1a, 2/03 AUTOMATION P R O D U C T S G R O U P, I N C. Operator s Manual Acoustical Flow Sensor for Solids Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com Table of Contents

More information

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/lowvoltage

More information

Ordering Information. Power Relay G2A. Model Number Legend Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control

Ordering Information. Power Relay G2A. Model Number Legend Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control Power Relay CSM DS_E_3_1 Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control Card lift-off employed for greater life and stable quality. Long endurance and stable quality are assured by

More information