1 DDM350 Pen-Type Digital Multimeter User s Manual
2 CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY....1 Out of the Box...1 Accessories Safety Information...2 Safety Symbols...3 Certification INTRODUCTION...4 Overview...4 Buttons and Components...4 Display Description USING THE METER Preparation...7 DC/AC Voltage Measurement DC/AC Current Measurement Resistance Measurement Diode Test...9 CONTENTS Capacitance Measurement Continuity Frequency/Duty Cycle Data Hold...12 Backlight...12 Work light NCV (Non-Contact Voltage) Auto Off SPECIFICATIONS General Specification...13 Technical Specification...14 MAINTENANCE AND REPAIR Repair Test Leads Replacement...18 Replacing the batteries...18 CONTACT DAWSON
3 LIMITED WARRANTY AND LIMITATION OF LIABILITY This instrument from Dawson Tools Inc. will be free from defects in workmanship and material for three years from the date of original purchase.this warranty does not cover defects resulting from damage caused by the user such as drops, neglect, misuse, unauthorized alteration, usage outside of specified conditions, contamination, or improper repair/ maintenance.to receive service on the instrument if it becomes necessary during the warranty period, contact your nearest Dawson authorized service center at (800) or visit to obtain a return authorization (within the US only). A return authorization is necessary before returning any instrument to Dawson; no service will be provided without a return authorization.the user is responsible for properly packing the unit and charges such as shipping, freight and insurance charges.the extent of Dawson's liability is limited solely to the repair/ replacement of the instrument.the above warranty in its entirety is inclusive and no other warranties, written or oral, are expressed or implied. Out of the Box Check the meter and accessories thoroughly before using the meter. Contact your local distributor if the meter or any components are damaged or malfunction. Accessories Test Lead Alligator Clip & cable 1.5V AAA Battery Case 1 pcs 1 pcs 2 pcs 1 pcs 5 User s Manual 1 pcs Safety Information To reduce the risk of fire, electrical shock, product damage or personal injury, please follow the safety instructions described in the user s manual. read the manual before using the meter. To ensure safe operation and life of the meter, do not place the meter in any environment with high pressure, high temperature, dust, explosive gas or vapor. 1.Avoid shaking, dropping or any kind of impacts when using or transporting the meter. 2.To avoid electric shock or personal injury, repairs or servicing not covered in this manual should be performed only by qualified personnel. 3.Avoid direct exposure to sunlight to ensure extended life of the meter. 4.Do not place meter in a strong magnetic field; this may cause false readings. 5.Use only the batteries indicated in the Technical Spec
4 6.Avoid exposing batteries to humidity. Replace batteries as soon as the low battery indicator appears. 7.Please keep the original packing for future shipping purposes (ex. Calibration) 8.After opening the box, check for any damage during delivery. Safety Symbols CATIII CE Important safety information, please refer to the user s manual Earth ground Indicates compliance with requirements for double insulation Fuse must be replaced with ratings specified in the manual. Conforms to IEC standards for overvoltage in category III installations with a pollution degree of II. Complies with European Union (EU) standards Complies with U.S. and Canadian safety standards. Important Safety Information Never use the meter to measure voltages that might exceed 600V DC/AC above earth ground in category III installations. Always be careful when working with voltage above 60V DC or 30VAC RMS. Keep fingers behind the probe barriers while measuring. Inspect test leads and probes for cracks, breaks or crazes on the insulation before using the meter. Repair or maintenance should be implemented by trained personnel only. Certification CAT I II:This meter has met IEC standard with an overvoltage category (CAT III) and pollution degree of 2. The meter complies to EMC requirements. Introduction Overview The DDM350 is a portable pen-type digital multimeter featuring DC/AC voltage and current measurements, resistance, capacitance, continuity, diode testing, frequency and duty cycle, auto/manual range, worklight, and an LCD w/backlight for easy reading. The slim and lightweight design is mobile and ideal for both professionals and hobbyists. Figures and Components Buttons and Components 1.Test Probe (+) 2.Probe Cap 3.NCV Indicator 4.Protective Ring 5.LCD Display 6.Rotary Switch 7.FUNC (Function) Button 8.RAN () Button 9. (Work light) Button 10.NCV (Non-Contact Voltage) Button 11.H/ (Hold/Backlight) Button 12.Hz/% (Frequency/Duty Cycle) Button 13.COM Jack (-) 03 04
5 Display Description Buttons and Components Description FUNC Button RAN Button COM Button NCV Button H/ Button Hz/% Button Probe Cap Switch between AC/DC or between resistance, continuity, diode or capacitance Choose auto or manual range Hold to turn on the work light Hold to activate Non-Contact Voltage measurement Hold data reading/turn on/off backlight Switch between frequency/duty cycle functions Rotary Switch Select different functions Probe + Input for V/A/Ω/ / / /Hz/% Common terminal Protective cap to be used when making CAT III or above measurements Protective Ring Keep hand behind the ring for safety AC Alternating Current DC Direct Current % Duty Cycle Hz Frequency C F Celsius/Fahrenheit n,µ,m,k,m nano, micro, milli, kilo, mega Ω Ohms (resistance) F Farad (capacitance) A Ampere (current) V Volt (voltage) Diode Buzzer Data hold AUTO Auto range Low battery indicator 05 06
6 Using the Meter Preparation Select a function and a range for the item to be measured using the rotary switch and RAN button if necessary. In manual range if the range to be measured is unknown, start with the highest range. In manual range, OL is displayed when overload occurs. Choose a higher range. To perform measurement, first connect the test lead to common (COM) input then connect the probe tip of the Meter to the circuit to be tested. If the battery voltage is less than 2.4V, is displayed. Please change the batteries. DC/AC Voltage Measurement Use caution when measureing high voltage circuits to avoid electrical shock and injury. do not test voltages higher than dc/ac 600v. Make sure the probe cap is screwed on if making CAT III or higher measurements. Insert the black test lead or lead with test clip in the COM jack. Set the rotary switch to the V position. Press the FUNC button to switch between DC and AC measurements. Manual range can be selected by pressing the RAN button. Hold RAN to go back to Auto range. Connect the probe tip of the meter and tip of the test lead (or test clip) across the voltage source or load. Read the measurement on the display. The polarity of the meter s + probe will be indicated. NOTE: At small voltage ranges the meter may show unsteady readings when test leads are not connected to the circuit, this is normal because of the sensitivity of the meter. When the meter is connected to the circuit, true readings will be displayed. DC/AC Current Measurement Use caution when measureing high voltage circuits to avoid electrical shock and injury. do not test voltages higher than dc/ac 600v. Make sure the probe cap is screwed on if making CAT III or higher measurements. Insert the black test lead or lead with test clip in the COM jack. Set the rotary switch to the ma position. Press the FUNC button to switch between DC and AC measurements. Manual range can be selected by pressing the RAN button. Hold RAN to go back to Auto range. Connect the probe tip of the meter and tip of the test lead (or test clip) across the power source or load. Read the measurement on the display. The polarity of the meter s + probe will be indicated
7 Resistance Measurement To avoid electrical shock and injury, power off the circuit and discharge the capacitance before measuring resistance. Insert the black test lead or lead with test clip in the COM jack. Set the rotary switch to the Ω position. Manual range can be chosen by pressing the RAN button. Hold RAN to go back to Auto range. Connect the probe tip of the meter and tip of the test lead (or test clip) across the resistance or circuit under measurement and read the measured value on the display. NOTE: The meter may take a few seconds to reach steady reading if the measured resistance is above 1MΩ. When the input is not connected (i.e. an open circuit) OL will be displayed. Diode Test Insert the black test lead or test clip in the COM jack. Set the rotary switch to the position. Press FUNC to choose diode measurement; is displayed. Connect the probe tip of the meter and tip of the test lead (or test clip) across the diode under measurement and read the measured value on the display. NOTE: The Meter shows the forward voltage drop. If the lead connection is reversed, OL is displayed. Capacitance Measurement To avoid electrical shock and injury, power off the circuit and discharge the capacitance before measuring capacitacne. Insert the black test lead or lead with test clip in the COM jack. Set the rotary switch to the position.press FUNC twice to choose capacitance measurement.there is no manual range available in capacitance mode. Connect the probe tip of the meter and tip of the test lead (or test clip) across the capacitance or circuit under measurement and read the measured value on the display. NOTE: The meter may take a few seconds to reach steadyeading when making high capacitance measurements. Continuity To avoid electrical shock and injury power off the circuit and discharge the capacitance before measuring continuity. Insert the black test lead or lead with test clip in the COM jack. Set the rotary switch to the position. Press FUNC 3 times to choose continuity test; is displayed. Connect leads to the circuit terminals. If continuity exists (i.e. resistance is less than 50Ω), the built-in buzzer will sound
8 If the result is an open circuit (or the measured circuit resistance is higher than 200Ω) 0L is displayed. Frequency/Duty Cycle Use caution when measureing high voltage circuits to avoid electrical shock and injury. do not test voltages higher than dc/ac 600v. Make sure the probe cap is screwed on if making CAT III or higher measurements. Insert the black test lead or test clip in the COM jack. Set the rotary switch to the Hz% position; Hz is displayed. Connect the probe tip of the meter and tip of the test lead (or test clip) across the source or load for measurement and read the measured frequency on the display. Press Hz% to switch to duty cycle measurement; % is displayed. Connect the probe tip of the meter and tip of the test lead (or test clip) across the source or load for measurement and read the measured duty cycle on the display. Alternatively, while in AC voltage or AC current modes, pressing the Hz% button will switch to frequency mode.press the button again to switch to duty cycle. Press the button a third time to return to voltage/current mode. Data Hold To hold a reading, press the / button and the current reading will be held on the display. Press the button again to return to normal reading. Backlight Hold the / button for two seconds to turn on backlight. The backlight will go off automatically after 10 seconds. Hold the / button again to manual turn off the backlight. Work light While the meter is on in any position, hold the button to turn on the work light.use this in areas that are poorly illuminated to make measurements easier. NCV (Non-Contact Voltage) While the meter is on in any position, hold the NCV button to turn check for the presence of voltage. Move the top of the meter toward the voltage source and if the voltage detected is >110VAC, the meter will beep and the NCV indicator will flash. NOTE: Do not rely solely on NCV detection to determine the presence of voltage in a conductor.socket design, insulation, interference, etc. can affect detection. Auto Off When not in use, the Meter will automatically turn off after approx. 15 minutes. After auto off, press FUNC to turn the power back on. The Meter will beep 5 times 1 minute before and a long beep right as it turns off. Hold the FUNC button while turning on the meter to disable auto off
9 Specifications General Specifications Environment Conditions Pollution Degree 2 Maximum Operating Altitude Operating Temperature Storage Temperature Max. Voltage Between Terminals And Earth Ground Auto s and Manual Display 600V CAT. III 7000 Ft (2000m) 0~40 C, 32 F~122 F (<80% RH, <10 non-condensing) 20mm LCD Max. Display Value 3999 (3 3/4 digit display) Polarity Indication: - indicates negative polarity. Overrange Indication Display shows OL. Sampling Time Unit Display approx. 0.4 second Displays function and measured value. Low Battery Indication displayed Fuse Protection: -10~50 C, 14 F~122 F (<70% RH, battery removed) 600V DC or AC FF400mA/600V Auto power off time 15 min. Power Supply 1.5V 2 AAA battery. Dimension Weight Technical Specifications DC voltage 400mV 4V 40V 400V 600V Resolution 0.1mV 0.001V 0.01V 0.1V 1V 8.9x1.6x1.4 in. ( mm) approx. 4.48oz (127g) including battery sss ±(0.5% reading + 3 digits) - Input Impedance: 10MΩ - Overload Protection: 400mV range: 250V DC or AC rms 4V to 600V ranges: DC 600V or AC 600V rms - Max. Input Voltage: 600V DC 13 14
10 AC voltage Resolution 400mV 4V 40V 400V 600V 0.1mV 0.001V 0.01V 0.1V 1V ±(0.8% reading + 3 digits) ±(0.8% reading + 3 digits) ±(1.0% reading + 3 digits) - Input Impedance: 10MΩ - Overload Protection: 400mV range: 250V DC or AC rms 4V to 600V ranges: DC 600V or AC 600V rms. - Frequency range: 40 to 400hz - Response: True RMS - Maximum input voltage: 600V AC rms DC Current Resolution 40mA 0.01mA ±(1.5% reading + 3 digits) 400mA 0. 1 ma - Overload protection: resettable fuse 400mA/600V AC Current Resolution 40mA 0.01mA ±(2.0% reading + 3 digits) 400mA 0. 1 ma - Overload protection: resettable fuse 400mA/600V - Frequency : 40 to 400Hz - Response: True RMS Resistance 400Ω 4kΩ 40kΩ 400kΩ 4MΩ 40MΩ Resolution 0.1Ω 0.001kΩ 0.01kΩ 0.1kΩ 0.001MΩ 0.01MΩ Resolution 0.001V Function ±(1.0% reading + 3 digits) ±(1.0% reading + 1 digits) ±(1.0% reading + 5 digits) - Open circuit voltage:1.0v - Overload protection: 250V DC or AC (RMS) Diode Function Displays diode forward voltage - Forward DC Current: 1mA - Reversed DC Voltage: 3.2V - Overload Protection: 250V DC or RMS AC Continuity If resistance is lower than 50Ω, the built in buzzer will sound. - Open circuit voltage: 1.0V - Overload Protection: 250V DC or RMS AC 15 16
11 Frequency/Duty Cycle Function Hz % 0-10MHz 1-99% ±(0.5% reading + 3 digits) ±(3.0% reading + 3 digits) - Overload Protection: 250V DC or AC RMS Capacitance 4nF 40nF 400nF 4µF 40µF 400µF 4mF 40mF Resolution 0.001nF 0.01nF 0.1nF 1nF 0.01µF 0.1µF 1µF 0.01µF ±(4.0% reading + 10 digits) - Overload Protection: 250V DC or AC RMS Maintenance and Repair Repair Please follow these steps closely if the meter is not functioning properly: Check the batteries; replace with new batteries if low battery indicator appears. Follow the user s manual to confirm all procedures. Before sending the meter back for repair, include a description of the problems encountered. Remove batteries and pack the meter well to avoid damage during delivery; Dawson does not cover damage due to delivery. Repair or service not covered in this manual should be performed only by the authorized service center or qualified personnel. Test Leads Replacement Replace the test leads with identical or compatible leads. lead spec:600v 10A. Replace new leads if the current leads are worn or damaged. Replacing the batteries Follow these steps to replace the batteries: Turn off the meter. Loosen the battery cover and remove the cover from the case s bottom. Remove the batteries and replace them with new ones. Re-attach the battery cover to the case s bottom and tighten the screw
12 Contact Dawson Dawson Tools, Inc S. Diamond Bar Blvd., #858 Diamond Bar, CA Phone: (310) Features True RMS LCD Display Auto and Manual Auto Power Off Diode Test Audible Continuity Non-Contact Voltage Detection Work light Backlight Data Hold Low Battery Indicator
Dawson DDM190. Digital Multimeter User s Manual
Dawson DDM190 Digital Multimeter User s Manual TABLE OF CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories.. Error! Bookmark not defined. Safety Information... 7
More informationDawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual
Dawson DDM230C True RMS Multimeter with Bar Graph Display User s Manual Table of Contents LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories... 4 Safety Information... 4
More informationDawson DDM181. Pocket-Size Autorange Digital Meter User s Manual
Dawson DDM181 Pocket-Size Autorange Digital Meter User s Manual 1 Table of Contents LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories... 4 Important Safety Information...
More informationDCM730. Digital Clamp Meter User s Manual
DCM730 Digital Clamp Meter User s Manual Table of Contents LIMITED WARRANTY AND LIMITATION OF LIABILITY...1 Out of the Box...1 Safety Information...2 INTRODUCTION...4 Components and Buttons...6 Names of
More informationMS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual
DUAL DISPLAY DIGITAL MULTIMETER User s Manual MS8250D 1. Safety Information Warning Use caution and follow all safety guidelines to prevent electric shock or damage to the meter. Please ready carefully
More informationMS8223A. CAT.IIi 600 V
Pen-type Digital Multimeter Manual MS8223A CAT.IIi 600 V CONTENTS 1. Safety Information......1 1.1 Preparing for use...1 1.2 During Use......2 1.3 Safety Symbols...3 1.4 Maintenance...4 2. Description......4
More informationMS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual
DUAL DISPLAY DIGITAL MULTIMETER User s Manual MS8250D Introduction MS8250D is a stable, safe, reliable compact digital handheld 6600 count, True RMS, auto-ranging multimeter. This meter can measure AC/DC
More informationPEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D
PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D T8211D 1 1. SAFETY INFORMATION BE EXTREMELY CAREFUL IN THE USE OF THIS METER. Improper use of this device can result in electric shock or destroy of
More informationDawson DSM150. Digital Light Meter User s Manual
Dawson DSM150 Digital Light Meter User s Manual TABLE OF CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of Box... Error! Bookmark not defined. Accessories... 4 Safety Information... 6 Certification...
More informationAC/DC DIGITAL CLAMP METER OPERATION MANUAL
AC/DC DIGITAL CLAMP METER OPERATION MANUAL HYS005661 A0 ACCESSORIES 6. ACCESSORIES 1) Test Leads: Electric Ratings 1000V 10A 1 pair (set) 2) Operating Manual 1 copy 3) 1.5V AAA Battery 3 piece - - 55 -
More information200Amp AC Clamp Meter + NCV Model MA250
User's Guide 200Amp AC Clamp Meter + NCV Model MA250 Introduction Congratulations on your purchase of this Extech MA250 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance,
More informationMS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL
MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL Ω CONTENTS CONTENTS 1. SAFETY INFORM...1 4.4 Range Transform...10 1.1 Preliminary...1 4.5 Auto Power Off...10 1.2 During use...2 4.6 Preparation For Measurement...11
More informationUser's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330
User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330 Introduction Congratulations on your purchase of the Extech EX330 Meter. The EX330 offers AC/DC Voltage, AC/DC Current,
More informationUser s Guide. 400A AC/DC Clamp Meter. Model MA220
User s Guide 400A AC/DC Clamp Meter Model MA220 Introduction Thank you for selecting the Extech MA200 AC/DC Clamp Meter. This meter measures AC/DC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,
More informationAC/DC CLAMP METER USER S MANUAL
AC/DC CLAMP METER USER S MANUAL CONTENTS PAGE SAFETY INFORMATION SYMBOL EXPLANATION SAFETY PRECAUTIONS 1 1 2 MAINTENANCE 3 GENERAL DESCRIPTION 4 PANEL DESCRIPTION 4 OPERATING INSTRUCTIONS... 7 SPECIFICATIONS
More informationAutoranging Multimeter Extech EX503
User's Guide Autoranging Multimeter Extech EX503 Introduction Congratulations on your purchase of the Extech EX503 Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current, Resistance,
More informationUser Manual. All rights reserved. Specifications are subject to change without notice.
User Manual All rights reserved. Specifications are subject to change without notice. LIMITED WARRANTY AND LIMITATION OF LIABILITY Customers enjoy one-year warranty from the date of purchase. This warranty
More informationMS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.
MS8250A/B DIGITAL MULTIMETER OPERATION MANUAL AUTO DC AC REL hfe PCLINK % C F kmωkz nµmfav MS8250A DIGITAL MULTIMETER Auto Power Off RANGE REL HOLD FUNC NCV A ma OFF 10A A ma 10A FUSED 600V CAT IV COM
More informationDIGITAL CLAMP METER Use s Manual
MS2026 MS2026R DIGITAL CLAMP METER Use s Manual MS2026 FUNC. RANGE MAX/MIN Hz/% HOLD AC CLAMP METER Auto Range AUTO DC AC MAX MIN REL μnf %Hz kmω mva CAT III 600 V CONTENTS 1. Safety Information...1 1.1
More informationCONTENTS MS2033A. 1.Introduction Safety Information...01
MS2033A AC Digital Clamp Meter User s Manual CAT III 600 V CONTENTS 1.Introduction...01 2.Safety Information...01 2.1 Precautions...02 2.2 Safety Symbols...03 3. Description...04 3.1 Front Panel...04 3.2
More informationMODEL: D03128 CLAMP METER
MODEL: D03128 CLAMP METER 1 CONTENTS Page Number Details 3 Important Safety Information 3 Features 4 Product Overview 5 Switches, Buttons & Input Jacks 5 LCD 6 Specifications 6 Electrical Specifications
More informationAMM-1022 Digital Multimeter USER`S MANUAL
Digital Multimeter USER`S MANUAL www.tmatlantic.com CONTENTS 1. SAFETY INFORMATION.3 2. DESCRIPTION..6 3. SPECIFICATIONS.8 4. OPERATING INSTRUCTION..11 4.1 Voltage measurement...11 4.2 Current measurement
More informationThank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at
ASTROAI USER MANUAL DT132A 4000 Count Auto-Ranging Multimeter Thank you for purchasing the AstroAI DT132A 4000 Count Auto-Ranging Multimeter. It is a 3 ¾ digit, 3999 counts, auto-ranging digital multimeter.
More information400Amp True RMS AC/DC Clamp Meter Model EX613
User's Guide 400Amp True RMS AC/DC Clamp Meter Model EX613 Introduction Congratulations on your purchase of this Extech EX613 True RMS Clamp Meter. This meter measures AC Current, DC Current, AC/DC Voltage,
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications
More informationEX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature
USER GUIDE True RMS Digital Multimeters EX350 Series EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature Table of Contents 1. INTRODUCTION 3 2. SAFETY INFORMATION 4 3.
More informationMM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE
INSTRUCTION MANUAL Auto-Ranging Digital Multimeter MM400 DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE 600V 10A 40MΩ 2 GENERAL SPECIFICATIONS Klein Tools MM400 is an auto-ranging
More informationINSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.
INSTRUCTION MANUAL Model 403380 Autoranging DMM ProbeMeter TM Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle. Back lit LCD with Autorange and full function displays Audible
More informationUser s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter
User s Manual MiniTec TM Series Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter Introduction Congratulations on your purchase of Extech s MN26 Autoranging Multimeter. This
More informationDIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS
CONTENTS CONTENTS CONTENTS 1. SAFETY INFORMATION...1 1.1 Preliminary...1 1.2 Dos and don ts...2 1.3 Symbols...3 1.4 Precautions...4 2. DESCRIPTION...5 2.1 Names of parts...6 2.2 Switches, buttons and input
More informationMS2109A AC/DC Clamp Meter. User Manual. Contents
MS2109A AC/DC Clamp Meter User Manual Contents 1. Safety information 1 1.1 Preparation 1 1.2 Usage 1 1.3 Signs and Labels 2 1.4 Maintenance 2 2. Description 2 2.1 Part name 3 2.2 Switch and button description
More informationDIGITAL MULTIMETER INSTRUCTION MANUAL
DIGITAL MULTIMETER INSTRUCTION MANUAL 1 CONTENTS CONTENTS 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 1 1.2 DURING USE 2 1.3 SYMBOLS 3 1.4 MAINTENANCE 4 2. DESCRIPTION 5 2.1 NAMES OF COMPONENTS 5 2.2 SWITCH,
More informationPen Multimeter. Model
Pen Multimeter Model 381626 CAUTION: Read, understand and follow all Safety Rules and Operating Instructions in this manual before using this product. This instrument is a 3200 count pen style digital
More informationCL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology
ENGLISH INSTRUCTION MANUAL 2000A Digital Clamp Meter True RMS Measurement Technology NON-CONTACT VOLTAGE TESTING INRUSH CURRENT LOW IMPEDANCE DATA HOLD RANGE HOLD AUDIBLE CONTINUITY DIODE TEST CAPACITANCE
More informationUser Manual Digital Multimeter
User Manual Digital Multimeter model no.: MSR-R500 Questions or Concerns? support@etekcity.com visit etekcity.com for more products Safe and Proper Usage Thank you for purchasing the Etekcity MSR-R500
More informationEM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use
http://www.all-sun.com EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL V Read this owners manual thoroughly before use WARRANTY This instrument is warranted to be free from defects in material and workmanship
More information1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10
CONTENTS 1. SAFETY INFORMATION.1 2. DESCRIPTION..4 3. SPECIFICATIONS.6 4. OPERATING INSTRUCTION..9 4.1 Voltage measurement...10 4.2 Current measurement 10 4.3 Resistance measurement...12 4.4 Diode test.12
More informationMM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology
INSTRUCTION MANUAL Auto-Ranging Digital Multimeter er True RMS Measurement Technology MM700 DATA & RANGE HOLD LOW IMPEDANCE AUDIBLE CONTINUITY MIN / MAX / RELATIVE TEMPERATURE DIODE TEST CAPACITANCE &
More informationNOTE: Fully read and understand this manual before using this Digital Multimeter.
ASTROAI USER MANUAL AUTO RANGING DIGITAL CLAMP METER Thank you for purchasing the Auto Ranging Digital Clamp Meter from AstroAI. The AstroAI Auto Ranging Digital Clamp Meter is designed to be safely and
More informationDigital Multimeter, Pen Type
MODEL: D03127 Digital Multimeter, Pen Type 1 CONTENTS Page Number Description 3 Important Safety Information 3 Electrical Symbols 4 Overview 4 Measurement Operation 5 AC & DC Voltage Measurement 5 AC &
More information400Amp True RMS AC Clamp Meter + NCV
User Guide 400Amp True RMS AC Clamp Meter + NCV Model MA410T Introduction Thank you for selecting the Extech MA410 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,
More informationUT207A/208A/209A Operating Manual. Table of Contents
Table of Contents Title Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Display Symbols Functional Buttons The Effectiveness
More informationUser's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 800 Amp AC/DC True RMS Clamp Meter Model EX730 Introduction Congratulations
More informationDIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL
DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A TABLE OF CONTENTS TITLE PAGE Safety Information Safety Symbols... 1 Meter Description...
More informationMS2030 CAT III 600 V A V AUTO RS232
MS2030 AC Digital Clamp Meter User s Manual CAT III 600 V AUTO RS232 A V CONTENTS 1.Introduction...1 2.Safety Information...1 2.1 Precautions...1 2.2 Safety Symbols...3 3. Description...4 3.1 Front Panel...4
More informationUSER MANUAL 600A AC Clamp Meter + NCV Model MA610
USER MANUAL 600A AC Clamp Meter + NCV Model MA610 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech MA610 Clamp Meter. This meter measures
More informationMM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS
INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS Measurement Technology MM700 DATA & RANGE HOLD LOW IMPEDANCE AUDIBLE CONTINUITY MIN / MAX / RELATIVE TEMPERATURE DIODE TEST CAPACITANCE & FREQUENCY
More informationAM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual
AM-510 Commercial / Residential Multimeter AM-510-EUR Digital Multimeter Users Manual AM-510 Commercial / Residential Multimeter AM-510-EUR Digital Multimeter English Users Manual Limited Warranty and
More information99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com #61-732 #61-736 400 AAC Clamp Meter Instruction Manual AC HOLD APO DC KMΩ mva WARNING Read First: Safety Information Understand
More informationMS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL
MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL Table of Contents TITLE PAGE 1. GENERAL INSTRUCTIONS 1 1.1 Precaution safety measures 1 1.1.1 Preliminary 1 1.1.2 During use 2 1.1.3 Symbols
More informationUser Guide. Digital AC/DC Clamp Meter Model 38394
User Guide Digital AC/DC Clamp Meter Model 38394 Introduction Congratulations on your purchase of Extech s 38394 AC/DC Clamp Meter. This clamp meter measures AC/DC Current to 600A, DC/AC Voltage, Resistance,
More informationUser Manual. All rights reserved. Specifications are subject to change without notice.
User Manual All rights reserved. Specifications are subject to change without notice. LIMITED WARRANTY AND LIMITATION OF LIABILITY Customers enjoy one-year warranty from the date of purchase. This warranty
More information600A Clamp Meters w/tightsight Display
V 750V #61-764 #61-766 #61-768 600A Clamp Meters w/tightsight Display Instruction Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com CAT.IV 600V CAT.III 1000V 600A 61-766
More informationUser s Guide. Digital AC/DC Clamp Meter Model 38394
User s Guide Digital AC/DC Clamp Meter Model 38394 Introduction Congratulations on your purchase of Extech s 38394 AC/DC Clamp Meter. This clamp meter measures AC/DC Current to 600A, DC/AC Voltage, Resistance,
More informationUSER'S MANUAL DMR-4350
USER'S MANUAL DIGITAL MULTIMETER DMR-4350 CIRCUIT-TEST ELECTRONICS www.circuittest.com TABLE OF CONTENTS SAFETY Safety Information...................................... 2 Safety Symbols........................................
More informationProfiScale MULTI Multimeter
1,5 V 9V 200 mv 600 V 200 ma 1/10 A ProfiScale MULTI Multimeter en Operating instructions BURG-WÄCHTER KG Altenhofer Weg 15 58300 Wetter Germany Introduction Want the reassurance of knowing whether current
More informationKMD-S04 Multímetro de bolsillo
www.grupotemper.com KMD-S04 Multímetro de bolsillo Table of Contents Title Page Overview ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 3 Unpacking Inspection ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 4 Safety Information
More informationR/C SMD Tweezers Multimeter Model RC200
User's Guide R/C SMD Tweezers Multimeter Model RC200 Introduction Congratulations on your purchase of the Extech RC200 RC Tweezers Multimeter This meter, using the tweezers adaptor, measures SMD capacitors,
More informationUSER'S MANUAL DMR-6700
USER'S MANUAL Multimeter True RMS DMR-6700 CIRCUIT-TEST ELECTRONICS www.circuittest.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),
More informationModel ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com
Model ST-9933 True RMS Autoranging Digital Multimeter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-8 Technical...4-5 Accuracy...5-8 Display Description...
More informationModel DIGITAL MULTIMETER
Model 57070 DIGITAL MULTIMETER INSTRUCTION MANUAL SAFETY INFORMATION To ensure safe operation, and in order to exploit to the full the functionality of the meter, please follow the directions in this section
More informationUser Manual Digital Multimeter. model no.: MSR-U1000
User Manual Digital Multimeter model no.: MSR-U1000 This Operating Manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings and Notes
More informationAC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español
Owner's Manual AC/DC Clamp Meter Model No. 82369 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español
More informationMS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS
CONTENTS MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 2 1.2 DURING USE 3 1.3 SYMBOLS 5 1.4 MAINTENANCE 6 2. DESCRIPTION 8 2.1 NAMES OF COMPONENTS 9
More informationDVM1190 DIGITAL MULTIMETER
DIGITAL MULTIMETER 1. Introduction Thank you for buying the. This digital multimeter has a large LCD, a data-hold function and a backlight. The device uses a very practical safety mechanism that keeps
More informationDL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter
DL6508 User's Guide 1500Amp True RMS AC/DC Clamp Meter Introduction Congratulations on your purchase of this DL6508 True RMS Clamp Meter. This meter measures AC Current, DC Current, AC/DC Voltage, Resistance,
More informationTrue RMS Digital Multimeter Model:
True RMS Digital Multimeter Model: 72-7780 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,
More informationUser's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer
User's Guide Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer EX810 AC Clamp meter EX820 True RMS AC Clamp meter EX830 AC/DC True RMS Clamp meter Patented Introduction Congratulations on your
More informationSafety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.
9305 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates
More informationDigital Clamp Meter. User Manual
Digital Clamp Meter User Manual CM240 WWW.OWON.COM.CN Mar. 2016 edition V1.2 Copyright LILLIPUT Company. All rights reserved. The LILLIPUT's products are under the protection of the patent rights, including
More informationDM-45 Digital Multimeter
INSTRUCTION MANUAL DM-45 Digital Multimeter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Description The Greenlee DM-45 Digital
More informationPen Multimeter. Model
Pen Multimeter Model 381626 CAUTION: Read, understand and follow all Safety Rules and Operating Instructions in this manual before using this product. This instrument is a 3200 count pen style digital
More informationHandheld Digital Multimeter PRO-50A
Handheld Digital Multimeter PRO-50A Safety Summary A statement calls attention to an operating procedure, practice, or condition, which, if not followed correctly, could result in injury or death to personnel.
More information1.General instructions Specifications Description...7
USER S Manual CONTENTS 1.General instructions...1 1.1 Precautions safety measures...1 1.1.1 Preliminary...1 1.1.2 During use...2 1.1.3 Symbols...4 1.1.4 Instructions...5 1.2 Protection mechanisms...6 2.
More informationOPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER
OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER with Temperature Probe Copyright 2007 Elenco Electronics, Inc. Contents 1. Safety Information 3,4 2. Safety Symbols 5 3. Front Plate
More information312, 316, 318. Clamp Meter. Users Manual
312, 316, 318 Clamp Meter Users Manual PN 1989445 July 2002 Rev.2, 2/06 2002, 2006 Fluke Corporation. All rights reserved. Printed in China. All product names are trademarks of their respective companies.
More informationAccuracy 1.2 PERCENT AC VOLTAGE, 0.5 PERCENT DC VOLTAGE, 1.5 PERCENT DC CURRENT, 1 PERCENT RESISTANCE, 2.5 PERCENT TEMPERATURE Battery Type
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 61603 Digital Multimeter Ideal Catalog Number 61603 Manufacturer Ideal Description Multimeter, Digital; Parameter Measured
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-352 The Service Information provides the following information: Precautions and safety information Specifications Basic maintenance (cleaning, replacing
More informationModel UT10A: OPERATING MANUAL Table of Contents (1)
Table of Contents (1) Table of Contents Title Page Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Functional Buttons Measurement
More informationUSER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330
USER MANUAL Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330 Introduction Congratulations on your purchase of the Extech EX330 Meter. The EX330 offers AC/DC Voltage, AC/DC Current, Resistance,
More informationUser s Guide. Model MA A AC Mini Clamp-on Meter
User s Guide Model MA150 200A AC Mini Clamp-on Meter Introduction Congratulations on your purchase of Extech s MA150 AC Mini Clamp Meter. This meter is shipped fully tested and calibrated and, with proper
More informationDIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.
MS8265 DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD ON/OFF LIGHT 1000V CAT II 600V CAT III MS8265 200K 2M 20M 20K 200M KHz 2K 20 200 2 20 200μ 200 20μ 750 2μ 1000 200n F 20n 10A 2m 200m 10 10
More informationUser s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130
User s Guide MultiView Series Digital MultiMeters Models: MV110 MV120 MV130 WARRANTY EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year
More informationUser s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free
User s Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 400A AC/DC Clamp Meter Model MA220 Introduction Thank you for selecting
More informationModel : OPERATING MANUAL Table of Contents (1)
Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Functional Buttons Measurement Operation A. DC
More informationUSER S MANUAL DMR-1500
USER S MANUAL DIGITAL POCKET MULTIMETER DMR-1500 CIRCUIT-TEST ELECTRONICS www.circuittest.com TABLE OF CONTENTS SAFETY Safety Information............................... 2-3 Safety Symbols...................................
More informationETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL
ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL 1 1. SAFETY INFORMATION SAFETY SYMBOLS Warning! Dangerous Voltage (Risk of electric shock). Caution! Refer to the user s manual before using this
More informationEX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC
USER MANUAL True RMS Digital Multimeters EX360 Series EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC EX365 True RMS DMM with 10A AC/DC Current Additional User Manual
More informationDMM8900 SERIES USERS MANUAL
DMM8900 SERIES USERS MANUAL WARRANTY This instrument is warranted to be free from defects in material and workmanship for a period of one year. Any instrument found defective within one year from the delivery
More informationAX-C Introduction. 2. Safety Information
AX-C708 1. Introduction Read Safety Information before using the meter. ProcessMeter ( referred to as the meter )is a handheld, battery-operated tool for measuring electrical parameters. It has all the
More informationIDM 61/62T Instruction Digital Multimeter Manual
IDM 61/62T Digital Multimeter Instruction Manual # Safety Information Read and understand this Instruction Manual completely before using this instrument. Failure to observe the warnings and cautions in
More informationInstruction Manual IDM 61/62T Digital Multimeter EN DE ES IT FR
Instruction Manual IDM 61/62T Digital Multimeter EN DE ES IT FR Safety Information Read and understand this Instruction Manual completely before using this instrument. Failure to observe the warnings and
More informationCompact MultiMeters + Voltage Detector
Compact MultiMeters + Voltage Detector Combination MultiMeters with Built-in Non-Contact AC Voltage Detector To quickly check for the presence of AC Voltage before testing EX300 Series Features: 0.5% basic
More informationUSER'S MANUAL DMR-4300
USER'S MANUAL DIGITAL MULTIMETER DMR-4300 CIRCUIT-TEST ELECTRONICS www.circuittest.com TABLE OF CONTENTS SAFETY Safety Information...................................... 2 Safety Symbols........................................
More informationHANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL
HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL GENERAL INSTRUCTIONS This instrument complies with IEC 1010-1 (61010-1@IEC: 2001), CAT. II 1000V and CAT. III 600V overvoltage standards. See Specifications.
More informationUser Manual Digital Clamp Multimeter. model no.: MSR-C600
User Manual Digital Clamp Multimeter model no.: MSR-C600 Overview This Operating Manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings
More informationMultifunction Digital
MS2009A Multifunction Digital Clamp Meter User Manual 200/600 OFF 2/20 NCV SEL MAX V RAN HOLD OFF MS2009A AC CLAMP METER AUTO MAX C F kmω μmva CONTENTS Safety requirements...1 Safety signs...1 Notes...1
More informationTable of Contents Title Page
Table of Contents Title Page Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons Display Symbols
More informationUser's Guide Extech EX Amp Clamp Meter with IR Thermometer
User's Guide Extech EX810 1000 Amp Clamp Meter with IR Thermometer Patented Introduction Congratulations on your purchase of the Extech EX810 Clamp Meter. This meter measures AC/DC Voltage, AC Current,
More informationDigital Clamp Meter Model: &
Digital Clamp Meter Model: 72-7224 & 72-7226 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,