1 MIST SANITARY SERIES TM Microprocessor Integrated Sensor Transmitter Temperature 3A Approval Temperature sensor with 4 to 20 ma output Hermetically sealed transmitter within the sensor Field reprogrammable with PC interface module and software Standard Hygienic Clamp Union Style Connection ( TriClamp ) Custom and OEM Designs are Our Specialty

2 MIST MS01 Mini Sanitary Temperature Sensor w/extension Cable Instrument Connection Smooth shank ( N) 0.38 dia. D Hygenic clamp ( TriClamp ) 0.63 dia. 3.0 E 2.6 C L Custom Builder MODEL MS Patent No.: US 7,223,014 Canadian Patent Pending 11 Calibrated Temperature Range 05 0 o C to 50 o C ( 32 / 122 o F) 10 0 o C to 100 o C ( 32 / 212 o F) 15 0 o C to 150 o C ( 32 / 302 o F) 20 0 o C to 200 o C ( 32 / 392 o F) o C to 50 o C ( 58 / 122 o F) o C to 150 o C ( 58 / 302 o F) o C to 200 o C ( 58 / 392 o F) L* 50 o C to 200 o C ( 58 / 392 o F) H* 200 o C to 600 o C ( 328 / 1112 o F) * Code L & H are not factory calibrated. Requires customer calibration using the MIST PKIT. Notes: 1. MIST Temperature Sensors are factory calibrated at one point to an accuracy of ± º C or better. See MIST specs. 2. For nonstandard temperature ranges, indicate desired value in º C or º F in Box1 or see web site 3. Order MIST PKIT for sensor customization. BOX2 LP LD VA VB VD Output 420 ma loop, upscale burnout ( std.) 420 ma loop, downscale burnout 05 Vdc, 3wire 15 Vdc, 3wire 010 Vdc, 3wire Other outputs available. Consult factory. BOX3 BOX4 S BOX5 BOX6 N Probe Diameter D B 1/ (4.0 mm) C 3/ 16 D 1/ 4 Other diameters available. Consult factory. Probe Material Stainless steel 316 / 316L Other materials available. Consult factory. BOX7 N SR Probe Length L In 0.1 inch increments Ex.: 012= 1.2 long Extension Length C In 0.1 increments ( 1.0 Std. ) Ex.: N10 = 1.0 long Instrument Connection None, smooth shank Strain Relief Other connections available. Consult factory. BOX8 T12 Hygienic clamp union, 1/2 T34 Hygienic clamp union, 3/4 BOX9 PV TF TA TP 0 1 SF F1 F4 Extension Cable Type PVC insulation, 90 o C ( 195 o F ) max. Teflon insulation, Teflon with SS armor, Teflon with SS armor and polyolefin shrink, 90 o C ( 195 o F ) max. TT Teflon with SS armor and Teflon shrink, Note : 1. Leads E length 12 and less are single conductor Teflon insulation, 22 AWG Extension Cable Length E In inches Ex.: 060 = 60 long Surface Finish 32 μin ( 0.8 μm ) Ra max. or better 20 μin ( 0.5 μm ) Ra max., w / o EP 15 μin ( 0.4 μm ) Ra max., with EP A2.0

3 MIST MS03 Mini Sanitary Temperature Sensor w/extension Cable & Conduit Fitting Hygenic clamp ( TriClamp ) D 0.38 dia dia. Instrument Connection 1/2 NPT fitting ( EN) L C 2.6 E 3.0 Custom Builder MODEL MS Patent No.: US 7,223,014 Canadian Patent Pending 11 Calibrated Temperature Range 05 0 o C to 50 o C ( 32 / 122 o F) 10 0 o C to 100 o C ( 32 / 212 o F) 15 0 o C to 150 o C ( 32 / 302 o F) 20 0 o C to 200 o C ( 32 / 392 o F) o C to 50 o C ( 58 / 122 o F) o C to 150 o C ( 58 / 302 o F) o C to 200 o C ( 58 / 392 o F) L* 50 o C to 200 o C ( 58 / 392 o F) H* 200 o C to 600 o C ( 328 / 1112 o F) * Code L & H are not factory calibrated. Requires customer calibration using the MIST PKIT. Notes: 1. MIST Temperature Sensors are factory calibrated at one point to an accuracy of ± º C or better. See MIST specs. 2. For nonstandard temperature ranges, indicate desired value in º C or º F in Box1 or see web site 3. Order MIST PKIT for sensor customization. BOX2 LP LD VA VB VD Output 420 ma loop, upscale burnout ( std.) 420 ma loop, downscale burnout 05 Vdc, 3wire 15 Vdc, 3wire 010 Vdc, 3wire Other outputs available. Consult factory. BOX3 BOX4 S BOX5 BOX6 N Probe Diameter D B 1/ (4.0 mm) C 3/ 16 D 1/ 4 Other diameters available. Consult factory. Probe Material Stainless steel 316 / 316L Other materials available. Consult factory. BOX7 EN EE Probe Length L In 0.1 inch increments Ex.: 012= 1.2 long Extension Length C In 0.1 increments (1.0 Std. ) Ex.: N10= 1.0 long Instrument Connection 1/2 NPT male 1/2 NPS male BOX8 T12 Hygienic clamp union, 1/2 T34 Hygienic clamp union, 3/4 BOX9 PV TF TA TP 0 1 SF F1 F4 Extension Cable Type PVC insulation, 90 o C ( 195 o F ) max. Teflon insulation, Teflon with SS armor, Teflon with SS armor and polyolefin shrink, 90 o C ( 195 o F ) max. TT Teflon with SS armor and Teflon shrink, Note : 1. Leads E length 12 and less are single conductor Teflon insulation, 22 AWG Extension Cable Length E In inches Ex.: 060 = 60 long Surface Finish 32 μin ( 0.8 μm ) Ra max. or better 20 μin ( 0.5 μm ) Ra max., w / o EP 15 μin ( 0.4 μm ) Ra max., with EP A3.0

4 MIST MS05 Mini Sanitary Temperature Sensor w/m12 MicroConnector M12 MicroFemale Connector Extension cable molded PVC IP68/NEMA 6P, 40 ºC to 90 ºC 0.63 dia. Hygenic clamp ( TriClamp ) 0.38 dia. D 3.0 E 2.6 C L Custom Builder Patent No.: US 7,223,014 Canadian Patent Pending MODEL MS Calibrated Temperature Range 05 0 o C to 50 o C ( 32 / 122 o F) 10 0 o C to 100 o C ( 32 / 212 o F) 15 0 o C to 150 o C ( 32 / 302 o F) 20 0 o C to 200 o C ( 32 / 392 o F) o C to 50 o C ( 58 / 122 o F) o C to 150 o C ( 58 / 302 o F) o C to 200 o C ( 58 / 392 o F) L* 50 o C to 200 o C ( 58 / 392 o F) H* 200 o C to 600 o C ( 328 / 1112 o F) * Code L & H are not factory calibrated. Requires customer calibration using the MIST PKIT. Notes: 1. MIST Temperature Sensors are factory calibrated at one point to an accuracy of ± º C or better. See MIST specs. 2. For nonstandard temperature ranges, indicate desired value in º C or º F in Box1 or see web site 3. Order MIST PKIT for sensor customization. BOX2 LP LD VA VB VD Output 420 ma loop, upscale burnout ( std.) 420 ma loop, downscale burnout 05 Vdc, 3wire 15 Vdc, 3wire 010 Vdc, 3wire Other outputs available. Consult factory. BOX3 BOX4 S BOX5 BOX6 N Probe Diameter D B 1/ (4.0 mm) C 3/ 16 D 1/ 4 Other diameters available. Consult factory. Probe Material Stainless steel 316 / 316L Other materials available. Consult factory. Probe Length L In 0.1 inch increments Ex.: 012= 1.2 long Extension Length C In 0.1 increments ( 1.0 Std. ) Ex.: N10 = 1.0 long BOX8 T12 Hygienic clamp union, 1/2 T34 Hygienic clamp union, 3/4 BOX9 MC 0 N A2 A5 B2 B5 1 SF F1 F4 Connector Type M12 MicroMale Connector Other types of connectors availabe. Consult factory. Extension Cable E None Straight, 2 meters Straight, 5 meters Right angle, 2 meters Right angle, 5 meters Surface Finish 32 μin ( 0.8 μm ) Ra max. or better 20 μin ( 0.5 μm ) Ra max., w / o EP 15 μin ( 0.4 μm ) Ra max., with EP A4.0

5 MIST MS22 Sanitary Temperature Sensor w/extension Cable Applications and Uses MIST MS22 assemblies are an excellent choice where extreme operating conditions prevail in wash down situations and very wet environments. External cables will withstand washdowns and optional stainless steel armor or overbraid prevents abrasion wear. These assemblies come standard with a 1/4 diameter probe. Larger diameters or reduced tip probes are also available. Stock Items Intempco stocks the most commonly used MIST MS22 assemblies with the following features : Factory calibrated 420 ma output to a customer specified temperature range Teflon insulation 4conductor AWG 22 cable with SS Armor, 6 feet long (3M) Operating temperature range of 50 to 200 Deg. C Builtin, fully programmable, microprocessor based transmitter Order MIST PKIT to recalibrate to other temperature ranges 1.5 and 2 hygienic clamp union sizes available ( TriClamp ) Immersion lengths available are 2.5 and 4 and 6 1/4 probe diameter, stainless steel 316 To order a MIST MS22 with 2 hygienic clamp union, a 4 probe with a range of 25 to 125 o C, specify the inventory number and temperature range, ex.: MS22LT20040 (25/125) o C on your order. To field calibrate the MIST MS22, order the Intempco MIST PKIT which includes the module and software. Ordering Information (Order stock items using Intempco inventory number) Inventory Number (Teflon Jacket) Inventory Number ( Armored Jacket) Probe Length L Hygienic Clamp Union Size MS22LT15025TF MS22LT15025TA MS22LT15040TF MS22LT15040TA MS22LT15060TF MS22LT15060TA MS22LT20025TF MS22LT20025TA MS22LT20040TF MS22LT20040TA MS22LT20060TF MS22LT20060TA A5.0

6 MIST MS22 Sanitary Temperature Sensor w/extension Cable C 1.5 Std. Instrument Connection Strain Relief ( SR) 2.5 max. Note : To order the MIST MS22 with a 90 o bend, add suffix B after the model number. Ex.: MS22B Hygenic clamp ( TriClamp ) 0.63 dia. D Reduced Tip L C 1.5 Std. 2.6 E 3.0 Custom Builder MODEL MS22 _ Patent No.: US 7,223,014 Canadian Patent Pending 11 A6.0 Calibrated Temperature Range 05 0 o C to 50 o C ( 32 / 122 o F) 10 0 o C to 100 o C ( 32 / 212 o F) 15 0 o C to 150 o C ( 32 / 302 o F) 20 0 o C to 200 o C ( 32 / 392 o F) o C to 50 o C ( 58 / 122 o F) o C to 150 o C ( 58 / 302 o F) o C to 200 o C ( 58 / 392 o F) L* 50 o C to 200 o C ( 58 / 392 o F) H* 200 o C to 600 o C ( 328 / 1112 o F) * Code L & H are not factory calibrated. Requires customer calibration using the MIST PKIT. Notes: 1. MIST Temperature Sensors are factory calibrated at one point to an accuracy of ± º C or better. See MIST specs. 2. For nonstandard temperature ranges, indicate desired value in º C or º F in Box1 or see web site 3. Order MIST PKIT for sensor customization. BOX2 LP LD VA VB VD Output 420 ma loop, upscale burnout ( std.) 420 ma loop, downscale burnout 05 Vdc, 3wire 15 Vdc, 3wire 010 Vdc, 3wire Other outputs available. Consult factory. BOX3 BOX5 Probe Diameter D D 1/4 F 3/8 H 1/2 Sheath O.D. Tip O.D. DB 1/4 1/8 FC 3/8 3/16 HC 1/2 3/16 HD 1/2 1/4 JD 5/8 1/4 Other diameters available. Consult factory. BOX4 S BOX6 N Probe Material Stainless steel 316 / 316L Other materials available. Consult factory. BOX7 N SR EN EE Probe Length L In 0.1 inch increments Ex.: 065= 6.5 long Extension Length C In 0.1 increments ( 1.5 Std. ) Ex.: N15= 1.5 long Instrument Connection None, smooth shank Strain Relief 1/2 NPT male 1/2 NPS male Other connections available. Consult factory. BOX8 T10 Hygienic clamp union, 1 T15 Hygienic clamp union, 1.5 T20 Hygienic clamp union, 2 T25 Hygienic clamp union, 2.5 T30 Hygienic clamp union, 3 Other fittings available. See page 11 & consult factory. BOX9 PV TF TA TP 0 1 SF F1 F4 Extension Cable Type PVC insulation, 90 o C ( 195 o F ) max. Teflon insulation, Teflon with SS armor, Teflon with SS armor and polyolefin shrink, 90 o C ( 195 o F ) max. TT Teflon with SS armor and Teflon shrink, Note : 1. Leads E length 12 and less are single conductor Teflon insulation, 22 AWG Extension Cable Length E In inches Ex.: 060 = 60 long Surface Finish 32 μin ( 0.8 μm ) Ra max. or better 20 μin ( 0.5 μm ) Ra max., w / o EP 15 μin ( 0.4 μm ) Ra max., with EP

7 MIST MS24 Sanitary Temperature Sensor w/bevel Fitting Instrument Connection Smooth shank ( N) Bevel fitting D Reduced Tip 0.63 dia. 3.0 E 2.6 C 1.5 Std. L Patent No.: US 7,223,014 Canadian Patent Pending Custom Builder MODEL MS24 _ Calibrated Temperature Range 05 0 o C to 50 o C ( 32 / 122 o F) 10 0 o C to 100 o C ( 32 / 212 o F) 15 0 o C to 150 o C ( 32 / 302 o F) 20 0 o C to 200 o C ( 32 / 392 o F) o C to 50 o C ( 58 / 122 o F) o C to 150 o C ( 58 / 302 o F) o C to 200 o C ( 58 / 392 o F) L* 50 o C to 200 o C ( 58 / 392 o F) H* 200 o C to 600 o C ( 328 / 1112 o F) * Code L & H are not factory calibrated. Requires customer calibration using the MIST PKIT. Notes: 1. MIST Temperature Sensors are factory calibrated at one point to an accuracy of ± º C or better. See MIST specs. 2. For nonstandard temperature ranges, indicate desired value in º C or º F in Box1 or see web site 3. Order MIST PKIT for sensor customization. BOX2 LP LD VA VB VD Output 420 ma loop, upscale burnout ( std.) 420 ma loop, downscale burnout 05 Vdc, 3wire 15 Vdc, 3wire 010 Vdc, 3wire Other outputs available. Consult factory. BOX3 BOX5 Probe Diameter D D 1/4 F 3/8 H 1/2 Sheath O.D. Tip O.D. DB 1/4 1/8 FC 3/8 3/16 HC 1/2 3/16 HD 1/2 1/4 JD 5/8 1/4 Other diameters available. Consult factory. BOX4 S BOX6 N Probe Material Stainless steel 316 / 316L Other materials available. Consult factory. BOX7 N SR EN EE Probe Length L In 0.1 inch increments Ex.: 065= 6.5 long Extension Length C In 0.1 increments ( 1.5 Std. ) Ex.: N15= 1.5 long Instrument Connection None, smooth shank Strain Relief 1/2 NPT male 1/2 NPS male Other connections available. Consult factory. BOX8 A** B** C** D** E** F** G** CherryBurrell ( 16A1141 ), male std. CherryBurrell ( 16A1141 ), female Bevel Seat (16A) with 13H nut Bevel Seat ( 16A ) without nut Bevel Seat ( 16A ) female John Perry ( JP16A ) with 13H nut John Perry ( JP16A ) without nut ** 10=1 20=2 30=3 15= = 2.5 Other fittings available. See page 11 & consult factory. BOX9 PV TF TA TP 0 1 SF F1 F4 Extension Cable Type PVC insulation, 90 o C ( 195 o F ) max. Teflon insulation, Teflon with SS armor, Teflon with SS armor and polyolefin shrink, 90 o C ( 195 o F ) max. TT Teflon with SS armor and Teflon shrink, Note : 1. Leads E length 12 and less are single conductor Teflon insulation, 22 AWG Extension Cable Length E In inches Ex.: 060 = 60 long Surface Finish 32 μin ( 0.8 μm ) Ra max. or better 20 μin ( 0.5 μm ) Ra max., w / o EP 15 μin ( 0.4 μm ) Ra max., with EP A7.0

8 MIST MS25 Sanitary Temperature Sensor w/m12 MicroConnector C 1.5 Std. 2.5 max. Note : To order the MIST M25S with a 90 o bend, add suffix B after the model number. Ex.: MS25B Reduced Tip D Hygenic clamp ( TriClamp ) 0.63 dia. M12 MicroFemale Connector Extension cable molded PVC IP68/NEMA 6P, 40 ºC to 90 ºC L C 1.5 Std. 2.6 E 3.0 Patent No.: US 7,223,014 Canadian Patent Pending Custom Builder MODEL MS25 _ Calibrated Temperature Range 05 0 o C to 50 o C ( 32 / 122 o F) 10 0 o C to 100 o C ( 32 / 212 o F) 15 0 o C to 150 o C ( 32 / 302 o F) 20 0 o C to 200 o C ( 32 / 392 o F) o C to 50 o C ( 58 / 122 o F) o C to 150 o C ( 58 / 302 o F) o C to 200 o C ( 58 / 392 o F) L* 50 o C to 200 o C ( 58 / 392 o F) H* 200 o C to 600 o C ( 328 / 1112 o F) * Code L & H are not factory calibrated. Requires customer calibration using the MIST PKIT. Notes: 1. MIST Temperature Sensors are factory calibrated at one point to an accuracy of ± º C or better. See MIST specs. 2. For nonstandard temperature ranges, indicate desired value in º C or º F in Box1 or see web site 3. Order MIST PKIT for sensor customization. BOX2 LP LD VA VB VD Output 420 ma loop, upscale burnout ( std.) 420 ma loop, downscale burnout 05 Vdc, 3wire 15 Vdc, 3wire 010 Vdc, 3wire Other outputs available. Consult factory. BOX3 BOX5 Probe Diameter D D 1/4 F 3/8 H 1/2 Sheath O.D. Tip O.D. DB 1/4 1/8 FC 3/8 3/16 HC 1/2 3/16 HD 1/2 1/4 JD 5/8 1/4 Other diameters available. Consult factory. BOX4 S BOX6 N Probe Material Stainless steel 316 / 316L Other materials available. Consult factory. Probe Length L In 0.1 inch increments Ex.: 065= 6.5 long Extension Length C In 0.1 increments ( 1.5 Std. ) Ex.: N15= 1.5 long BOX8 0 N A2 A5 B2 B5 T10 Hygienic clamp union, 1 T15 Hygienic clamp union, 1.5 T20 Hygienic clamp union, 2 T25 Hygienic clamp union, 2.5 T30 Hygienic clamp union, 3 Other fittings available. See page 11 & consult factory. BOX9 MC 1 SF F1 F4 Connector Type M12 MicroMale Connector Other types of connectors availabe. Consult factory. Extension Cable E None Straight, 2 meters Straight, 5 meters Right angle, 2 meters Right angle, 5 meters Surface Finish 32 μin ( 0.8 μm ) Ra max. or better 20 μin ( 0.5 μm ) Ra max., w / o EP 15 μin ( 0.4 μm ) Ra max., with EP A8.0

9 MIST MS80 Sanitary Temperature Sensor w/connection Head Applications and Uses MIST MS80 assemblies are an excellent choice where extreme operating conditions prevail in wash down situations and very wet environments. Moisture and liquids accidentally entering the enclosure no longer damage the electronics, simply clean and use again. These assemblies come standard with a 1/4 diameter probe. Larger diameters or reduced tip probes also available. Stock Items Intempco stocks the most commonly used MIST MS80 assemblies with the following features: Factory calibrated 420 ma output to a customer specified temperature range FDA approved white polypropelene enclosures with 3/4 NPT electrical conduit connection. Operating temperature range of 50 to 200 Deg C Builtin, fully programmable, microprocessor based transmitter Order MIST PKIT to recalibrate to other temperature ranges 1.5 and 2 Triclamp sizes available Immersion lengths available are 2.5 and 4 and 6 with 1/4 probe diameters All stainless steel 316 wetted surfaces To order a MIST MS80 with 2 hygienic clamp union, a 4 probe with a range of 25 to 125 o C, specify the inventory number and temperature range, ex. MS80LT20040 (25/125) o C on your order. To field calibrate the MIST MS80, order the Intempco MISTPKIT which includes the module and software. Ordering Information (Order stock items using Intempco inventory number) Catalog Number Inventory Number Probe Length L Hygienic Clamp Union Size MS80LLPDS025N25EET15PO3SF MS80LT15025PO MS80LLPDS040N25EET15PO3SF MS80LT15040PO MS80LLPDS060N25EET15PO3SF MS80LT15060PO MS80LLPDS025N25EET20PO3SF MS80LT20025PO MS80LLPDS040N25EET20PO3SF MS80LT20040PO MS80LLPDS060N25EET20PO3SF MS80LT20060PO A9.0

10 MIST MS80 Sanitary Temperature Sensor w/connection Head PO3 head Instrument connection Hygienic clamp union connection D Reduced Tip C 2.5 Std. L Custom Builder Patent No.: US 7,223,014 B2 Canadian Patent Pending MODEL MS80 _ 0 Calibrated Temperature Range 05 0 o C to 50 o C ( 32 / 122 o F) 10 0 o C to 100 o C ( 32 / 212 o F) 15 0 o C to 150 o C ( 32 / 302 o F) 20 0 o C to 200 o C ( 32 / 392 o F) o C to 50 o C ( 58 / 122 o F) o C to 150 o C ( 58 / 302 o F) o C to 200 o C ( 58 / 392 o F) L* 50 o C to 200 o C ( 58 / 392 o F) H* 200 o C to 600 o C ( 328 / 1112 o F) * Code L & H are not factory calibrated. Requires customer calibration using the MIST PKIT. Notes: 1. MIST Temperature Sensors are factory calibrated at one point to an accuracy of ± º C or better. See MIST specs. 2. For nonstandard temperature ranges, indicate desired value in º C or º F in Box1 or see web site 3. Order MIST PKIT for sensor customization. BOX2 LP LD VA VB VD Output 420 ma loop, upscale burnout ( std.) 420 ma loop, downscale burnout 05 Vdc, 3wire 15 Vdc, 3wire 010 Vdc, 3wire Other outputs available. Consult factory. BOX3 Probe Diameter D D 1/4 F 3/8 H 1/2 Sheath O.D. Tip O.D. DB 1/4 1/8 FC 3/8 3/16 HC 1/2 3/16 HD 1/2 1/4 JD 5/8 1/4 Other diameters available. Consult factory. BOX4 BOX6 N Probe Material S Stainless steel 316 / 316 Other materials available. Consult factory. BOX5 BOX7 EN EE* Probe Length L In 0.1 inch increments Ex.: 065= 6.5 long Extension Length C In 0.1 increments ( 2.5 Std. ) Ex.: N25= 2.5 long Instrument Connection 1/2 NPT male 1/2 NPS male * Code EE is standard when ordereing with a head. BOX8 T10 Hygienic clamp union, 1 T15 Hygienic clamp union, 1.5 T20 Hygienic clamp union, 2 T25 Hygienic clamp union, 2.5 T30 Hygienic clamp union, 3 Other fittings available. See page 11 & consult factory. BOX9 0 PO* BA2 SS2 CS* CX* Head/ Termination No head, supplied with 6 single teflon leads White polypropylene screw cover, meets NEMA 4X / IP65 requirements Bakelite screw cover, meets NEMA 4X / IP65 requirements Machined & polished stainless steel 316 / 316L screw cover, meets NEMA 4X / IP66 requirements Cast stainless steel 316 screw cover, meets NEMA 4X / IP66 requirements Cast stainless steel, explosion proof, CSA, FM Approval Class I, Div. 1, Gps. B,C & D Class II, Div. 1, Gps. E, F & G, NEMA 4X *2= 1/2 NPT Conduit *3= 3/4 NPT Conduit 1 SF F1 F4 Surface Finish 32 μin ( 0.8 μm ) Ra max. or better 20 μin ( 0.5 μm ) Ra max., w / o EP 15 μin ( 0.4 μm ) Ra max., with EP A10.0

11 MIST Sanitary Series Hygienic clamp union connection Clamp Gasket Pipe Probe Clamp for hygienic connection Intempco Sanitary Series Intempco offers a complete line of hygienically designed process measurement devices which are perfectly suited for use in food, dairy, chemical, and pharmaceutical industries. Intempco sanitary sensors carry the 3A mark and are designed and manufactured to meet the requirements of 3A Sanitary Standards for Sensors and Sensors Fittings and Connections Number. Intempco sanitary sensors are easily installed into a tee, cross, or directly into a sanitary tube and feature all stainless steel construction. All popular sanitary connection styles available. Wetted surfaces are machined and polished to meet 3A standards and are free of pits and crevices that might shelter bacteria or impurities. Assemblies are hermetically sealed and built to withstand industrial washdowns. Intempco sanitary sensors contain an encapsulated platinum RTD Class A element providing high accuracy, repeatability and vibration resistance. Assemblies are available with a variety of electrical connections and connection heads ( including stainless steel, polypropylene and Bakelite ) for easy wiring. A wide variety of options are available, including dual elements and reduced tips which improve time response without compromising the mechanical strength of the sensor. MIST Series Sanitary Sensors have an integrated transmitter with a variety of output options such as 420 ma loop powered or 3 wire voltage output with 05 VDC, 15 VDC and 010 VDC options. CherryBurrell connection Clamp Gasket Pipe Bevel Seat connection Nut Probe Probe Pipe T12 T34 T10 T15 T20 T25 T30 T40 Hygienic clamp union, 1/2 per ASMEBPE Hygienic clamp union, 3/4 per ASMEBPE Hygienic clamp union, 1 per ASMEBPE Hygienic clamp union, 1.5 per ASMEBPE Hygienic clamp union, 2 per ASMEBPE Hygienic clamp union, 2.5 per ASMEBPE Hygienic clamp union, 3 per ASMEBPE Hygienic clamp union, 4 per ASMEBPE A15 CherryBurrell male I, 11/2 A20 CherryBurrell male I, 2 A25 CherryBurrell male I, 21/2 A30 CherryBurrell male I, 3 B15 CherryBurrell female I, 11/2 B20 CherryBurrell female I, 2 B25 CherryBurrell female I, 21/2 B30 CherryBurrell female I, 3 C15 Bevel Seat ( w/nut ), 11/2 C20 Bevel Seat ( w/nut ), 2 C25 Bevel Seat ( w/nut ), 21/2 C30 Bevel Seat ( w/nut ), 3 D15 Bevel Seat ( w/o nut ), 11/2 D20 Bevel Seat ( w/o nut ), 2 D25 Bevel Seat ( w/o nut ), 21/2 D30 Bevel Seat ( w/o nut ), 3 F15 John Perry ( w/nut ), 11/2 F20 John Perry ( w/nut ), 2 F25 John Perry ( w/nut ), 21/2 F30 John Perry ( w/nut ), 3 G15 John Perry ( w/o nut ), 11/2 G20 John Perry ( w/o nut ), 2 G25 John Perry ( w/o nut ), 21/2 G30 John Perry ( w/o nut ), 3 XXX Other, specify A11.0

12 MIST PKIT Programming Module & Software Description The MISTKIT is used to recalibrate and rescale MIST Temperature Sensors. Two methods of calibration are available. The first, called One Point Calibration, is performed by setting the MIST Temperature Sensor to a known temperature and adjusting the 420 ma output to the corresponding value. The second method, called Two Point Calibration, is performed by setting the MIST Temperature Sensor to a known point in the operating range and then recording this point by simply clicking the corresponding button. The next step is to set the MIST Temperature Sensor to a second known point in the operating range and record it in the same manner. Finally, by clicking on the Process button, the calibration parameters are automatically calculated and saved in the MIST Temperature Sensor memory. The MIST PKIT software can also be used to rescale the MIST Temperature Sensors output within its operational limits. A choice of many standard ranges are available via a dropdown menu. Custom ranges can alos be specified. Once the range is selected, simply clicking on the Set button will automatically rescale the output and save the new values in the MIST Temperature Sensor memory. Kit Includes MIST PKIT Calibration Interface Software MIST TM calibration software CD ROM Communication module with USB or RS232 interface 110 VAC Wall adapter ( for RS232 module ) or USB cable ( for USB module ) Minimum System Requirements Ordering Information MODEL MIST PKIT Communication Type 1 Serial, RS232 2 USB 1 _ Windows TM XP or Vista Pentium III 600 MHZ or better 10 MB of free disk space 256 MB of RAM 1 serial port or USB A12.0

13 MIST Sanitary Series TECHNICAL SPECIFICATIONS Electrical Properties Input : Sensor Temperature Ranges : Outputs : Minimum Input Impedance : Power Supply : Supply Effect : RTD, type Pt100 See Box1 code for standard ranges. Field rescalable between 200 o C to 600 o C or 50 o C to 200 o C, depending on model. 420 ma loop powered, 2wire, linear to temperature 05 Vdc, 15 Vdc, 010 Vdc all 3wire, linear to temperature 1000 Ohm (of measuring device, for voltage output) 1232 VDC, polarity protected %/V Accuracy : ±(.25 o C % of span ) with onepoint calibration 1. ±(.10 o C % of calibrated span ) with twopoint calibration 2. Maximum Loop Resistance : Sensor Open Circuit : Warmup : RFI Effect : Isolation : Temp. Effects : Long Term Drift : Mechanical Properties Sanitary Series Wetted Surface Material : Environmental Rating Head assemblies : Cabled probe and M12 connection : [( Vsupply 7 ) * 40 ] ohms (for 420 ma output only) Upscale 24 ma or Downscale 2.5 ma (for 420 ma output only) 30 seconds 1 % or less typical 500 VDC Input / Output ± % of Span / o C 0.1 % FS / Year Stainless steel 316 / 316L, dual certified Refer to head enclosures specifications Meets NEMA 6P ( IP67 ), hermetically sealed Cable Material : PVC, Teflon, SS armor over Teflon Protection : Storage Temp. Range : Meets NEMA 6P ( IP67 ), hermetically sealed 40 o C to 80 o C Operating Temp. Range : 40 o C to 80 o C ( housing only ) Maximum Operating Pressure : 500 PSIG ( applies to sensor portion only ) Standard Surface Finish : Code SF Maximum Ra of 32 μin ( 0.8 μm ) or better as per 3A Pharmaceutical Surface Finish : Code F1 Pharmaceutical Surface Finish : Code F4 Approbations 3 : Per ASME BPE 2009 SF1 20 μin ( 0.5 μm ) Ra max. without electro polish Per ASME BPE 2009 SF4 15 μin ( 0.4 μm ) Ra max. with electro polish 3A symbol authorization 3A Sanitary Standards for Sensors and Sensors Fittings & Connections Number Teflon is a reigistered trademark of E.I. du Pont de Nemours and Comapny. 1. Max. error on complete span. Error at calibration point 0.1 % of Span. 2. Max. error on complete calibrated span. Error at calibration points 0.1 % of Span. 3. Intempco sanitary sensors bearing the 3A symbol meet the requirements of 3A Sanitary Standards for Sensors and Sensor Fittings and Connections, Number, with some exceptions to section D10 for heat sterilization systems. Intempco sensors meet the requirements of section D10.1 and D for sterilization of the product contact surfaces, with exception made for section D and D Intempco sensors do not have a steam or other sterilization chamber surrounding the joint at the product contact surfaces between the fitting and the devices. A13.0

14 Notes : Intempco USA, Inc. 165 State Street, Suite C, Hackensack, NJ Tel.: (201) Fax : (201) Intempco Controls Ltd. 2511, Guenette, Montreal (Quebec) H4R 2E9 Tel.: (514) Fax : (514) A14.0

STANDARD RTD's INDEX

STANDARD RTD's INDEX STANDARD RTD's INDEX PAGE General Information... R2 Temperature/Resistance Table... R6 Part Numbering Examples... R10 High Temperature MgO Elements (RA)... R11 Leadwire Style RTD's (RB)... R12 Leadwire

More information

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products Data sheet DS/-EN Rev. T Magnetostrictive Level Transmitter External mounted magnetostrictive level transmitter K-TEK Products Features SIL2 Certified IEC 61508* Designed to mount externally to K-TEK KM26

More information

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output. Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model MR Transmitter with Analog Output Data Sheet SENSORS Document Part Number 550677 Revision K FEATURES 4 to 20

More information

Non-Submersible Industrial Pressure Transducer

Non-Submersible Industrial Pressure Transducer Non-Submersible Industrial Pressure Transducer KPSI Transducers Series 27, 28, 30 FEATURES Custom Pressure Ranges up to 2000 (13,790 kpa) Accuracy to ±0.10% FS Analog Outputs of 4-20 ma or VDC Welded 316

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

AT200 External Mount Magnetostrictive Level Transmitter

AT200 External Mount Magnetostrictive Level Transmitter Data sheet DS/AT200-EN Rev. W AT200 External Mount Magnetostrictive Level Transmitter High accuracy liquid level and interface level detection K-TEK Level Products Measurement made easy Features Certified

More information

UTM10 Series Ultrasonic Transit-time Flowmeters

UTM10 Series Ultrasonic Transit-time Flowmeters Ultrasonic Transit-time meters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal liquid. The technology has inherent advantages

More information

Load Cell Accessories and Services

Load Cell Accessories and Services Load Cell Accessories and Services Highlights Strain gage signal conditioners Cable assemblies Mounting accessories Calibration services PCB Piezotronics, Inc. Toll-Free in USA 888-684-0004 716-684-0001

More information

Precision Thermistor Sensors

Precision Thermistor Sensors Precision Thermistor Sensors For Laboratory Applications ON-400 Series U For Use in Laboratory or Other High-Accuracy Applications U Rugged Construction Can Be Used for Short Term Water and Soil Readings

More information

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES. SENSORS FOR FOOD AND LIFE SCIENCES. Product Information TSM and TSB FOOD Temperature Sensor Application/Specified usage Temperature Measurement in vessels and pipes Authorizations Application examples

More information

AT100S Magnetostrictive Level Transmitter. Sanitary magnetostrictive level transmitter K-TEK Products

AT100S Magnetostrictive Level Transmitter. Sanitary magnetostrictive level transmitter K-TEK Products Data sheet DS/AT100S-EN Rev. N AT100S Magnetostrictive Level Transmitter Sanitary magnetostrictive level transmitter K-TEK Products Features SIL2 Certified IEC 61508* High Accuracy:.01% of Full Scale Superior

More information

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet Product Data Sheet 00813-0101-4796 Model 144H PC-Programmable Temperature Transmitter FEATURES Configurable using the Model 144C Configuration Interface hardware and software Programmable via standard

More information

Magnetostrictive Level Transmitter

Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter The Model KMD is an advanced, state-of-the-art, two-wire, Magnetostrictive-based level transmitter suitable for a wide range of process applications. The latest in microprocessor

More information

Model Sono-Trak Transit Time

Model Sono-Trak Transit Time Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic

More information

Condumax CLS16 and CLS16D

Condumax CLS16 and CLS16D Technical Information Condumax CLS16 and CLS16D Hygienic conductivity sensor, analog or digital with Memosens technology, cell constant k = 0.1 cm -1 Application Measurement in pure and ultrapure water:

More information

Echotel Trident 91S/92S Ultrasonic Level Switches

Echotel Trident 91S/92S Ultrasonic Level Switches Echotel Trident 91S/92S Ultrasonic Level Switches D E S C R I P T I O N The Trident 91S/92S detects single or dual point level in a wide variety of liquid applications. It is available with either an ma

More information

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Technical Information TI 273T/02/en 60021667 RTD Temperature Sensor omnigrad T -TSM 480, TR 480 Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Application The Omingrad

More information

Two-Wire Programmable Transmitter for:

Two-Wire Programmable Transmitter for: TM Smart Process Instrumentation Revision 2 Two-Wire Programmable Transmitter for: Industrial Thermocouple or RTD Temperature Measurements Highlights: Exceptional speed and accuracy Guaranteed measurement

More information

Magnetostrictive Level Transmitter

Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter Overview Söm-Tek TM The SKMT liquid level transmitter satisfies the demand for an analog communication interface for sightglass (bypass

More information

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P - 4-20mA output, default range supplied 0-100 C ENGLISH The TX203P RTD in-head mounted temperature transmitter connects

More information

RTD TH17 and TH18. Technical Information. Sanitary RTD temperature assembly with connection head

RTD TH17 and TH18. Technical Information. Sanitary RTD temperature assembly with connection head Technical Information RTD TH17 and TH18 Sanitary RTD temperature assembly with connection head Areas of application The TH17 and TH18 sanitary temperature sensors are RTD s designed for use in dairy, food

More information

HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX, IECEx)

HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX, IECEx) Heading Product Name A Higher Level of Performance Data Sheet HAWK Magnetostrictive Level Transmitter For more information, please visit > www.hawkmeasure.com Model HLT Transmitter with Analog Output and

More information

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER Configuration Code TM01 Series 642 Programmable HART Field Temperature The Series 642 programmable HART field temperature transmitter is a 2-wire unit with analog output. It includes input for RTDs; resistance

More information

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration

More information

Echotel Model 910 Ultrasonic Level Switch

Echotel Model 910 Ultrasonic Level Switch Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit

More information

RTD & THERMOCOUPLE SENSOR ASSEMBLIES Sensors RTD & T/C Pricing Effective July 1, to December 31, 2017

RTD & THERMOCOUPLE SENSOR ASSEMBLIES Sensors RTD & T/C Pricing Effective July 1, to December 31, 2017 Wahl WR Series Industrial RTD Probes Ordering Form Step 1 - Select: RTD Sensor from WR Codes WR1 RTD Sensor - Standard 304 SS WR2 RTD Sensor - Standard 316 SS Step 2 - Select: Process Connection from corresponding

More information

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents KENCO ENGINEERING COMPANY P.O. BOX 470426, TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 http://www.kenco-eng.com e-mail: info@kenco-eng.com KENCO Loop Powered Magnetostrictive Transmitter

More information

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC Technical Information omnigrad T - TSM 480, TR 480 RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC Application areas The onmigrad T easytemp TSM 480 and TR 480 thermometers

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Materials (other materials see WIKA diaphragm seal program) Model S-10

Materials (other materials see WIKA diaphragm seal program) Model S-10 2.0 Specifications WIKA Tronic catalog pages and data sheets have a consistent layout of technical information that is required to select the correct transmitter. The second page of the data sheet lists

More information

Thin Film Deposition

Thin Film Deposition Thin Film Deposition Section Eleven 11 11.1 General Information 2 11.2 Deposition Monitors 3 11.3 Crystal Feedthroughs 4 11.4 Crystal s 5 11.5 Cables, s, Crystals & Accessories 6 Nor-Cal Products, Inc.

More information

Thin Film Deposition

Thin Film Deposition Thin Film Deposition Section Eleven 11 11.1 General Information 2 11.2 Deposition Monitors 3 11.3 Crystal Feedthroughs 4 11.4 s 5 11.5 Cables, s, Crystals & Accessories 6 Nor-Cal Products, Inc. 1967 South

More information

Thermocouples. Table of Contents. Industrial (A-2) Smart Model 1100 (A-26) Smart with Leads Model 1200 (A-27) Wire (A-32)...

Thermocouples. Table of Contents. Industrial (A-2) Smart Model 1100 (A-26) Smart with Leads Model 1200 (A-27) Wire (A-32)... Thermocouples Table of Contents page Industrial (A-2)... 2 Smart Model 1100 (A-26)... 3 Smart with Leads Model 1200 (A-27)... 4 Wire (A-32)... 5 sorinc.com 913-888-2630 Industrial Thermocouples M.I. Cable

More information

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box Applications Food and beverage industry Pharmaceutical industry Biotechnology industry Cosmetic industry Special Features Meets

More information

Level Plus. SoCLEAN Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology

Level Plus. SoCLEAN Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology SoCLEAN Sanitary and Electropolished Finish Inherent Accuracy ±1 mm No Scheduled Maintenance or Recalibration Hazardous

More information

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable) Specification Sheet 600T Series Transmitters Model 65T Electronic temperature transmitter (PC programmable) High flexibility and wide rangeability Single transmitter accepts RTD/THC/mV/ohm Galvanically

More information

NEUROLOGIC RESEARCH CORPORATION

NEUROLOGIC RESEARCH CORPORATION NEUROLOGIC RESEARCH CORPORATION MODEL 1100A INDUSTRIAL TEMPERATURE NETWORK TRANSMITTER High temperature/sealed sensing element construction. Digitally calibrated for high accuracy Electronics are sealed

More information

Echotel Model 910 Ultrasonic Level Switch

Echotel Model 910 Ultrasonic Level Switch Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 Applications Machine building, plant and vessel construction Propulsion

More information

OPTITEMP TT 20 Technical Datasheet

OPTITEMP TT 20 Technical Datasheet OPTITEMP TT 20 Technical Datasheet Analog PC-programmable two-wire transmitters for Pt100 Efficient PC-configuration without recalibration Very stable output Very fast response time The documentation is

More information

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter ata Sheet 902815 Page 1/13 JUMO trans T100 Screw-in RT Temperature Probe with/without Transmitter For temperatures between -50 and +260 C RoHS conformity for EU and China Configuration with setup program

More information

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter.   LEVEL. Technology Solutions Technology Solutions TEK-F LEX 4100A Guided Wave Radar Level Transmitter LEVEL www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Featuring TDR (Time Domain

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant

More information

KING-GAGE KING. ES2 Liquid Level Transmitter. Installation and Operation Instructions ma Liquid Level Transmitter EX-1834

KING-GAGE KING. ES2 Liquid Level Transmitter. Installation and Operation Instructions ma Liquid Level Transmitter EX-1834 Effective: April 2007 (Replaces January 2007) KING-GAGE 4-20 ma Liquid Level Transmitter ES2 Liquid Level Transmitter Installation and Operation Instructions Since 1937 KING E N G I N E E R I N G C O R

More information

Instruction Manual. Model MLA & MLD Loop Powered Process Indicators IM 61A01A-01E-A. Model MLA (Analog) Model MLD (Digital)

Instruction Manual. Model MLA & MLD Loop Powered Process Indicators IM 61A01A-01E-A. Model MLA (Analog) Model MLD (Digital) Instruction Manual Model MLA & MLD Loop Powered Process Indicators Model MLD (Digital) Model MLA (Analog) 1. PREFACE The Model MLA and MLD field mounted indicators receive DC voltage or current signals

More information

ED701 General Industry Pressure Transmitter

ED701 General Industry Pressure Transmitter ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Additel 875 Series Dry Well Calibrators

Additel 875 Series Dry Well Calibrators Additel 875 Series Dry Well Calibrators Three models ranging from -40 to 660 Portable, rugged, and quick to temperature Metrology-level performance in stability, uniformity, accuracy and loading effect

More information

Technical Information Smartec CLD18

Technical Information Smartec CLD18 TI01080C/07/EN/02.14 71264779 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application Compact measuring

More information

Conductivity sensor for hygienic applications

Conductivity sensor for hygienic applications Conductivity sensor for hygienic applications 2- or 4-electrode technology Extended measuring range 0.05 S/cm... 500 ms/cm Process connections, materials, surface finish designed for use in hygienic applications

More information

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16 Technical Information TI 7C//ae Conductivity Measuring Cells for High-Temperature Applications Two-electrode measuring sensors with fixed cable or connector version with integrated temperature sensor Cell

More information

HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)

HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX) Heading Product Name A Higher Level of Performance Data Sheet HAWK Magnetostrictive Level Transmitter For more information, please visit > www.hawkmeasure.com Model HLT Transmitter with Analog Output and

More information

Mineral-insulated resistance thermometers to EN

Mineral-insulated resistance thermometers to EN Data Sheet 90.2221 Page 1/6 Mineral-insulated resistance thermometers to EN 60 751 for temperatures from -50 (-200) to +600 C flexible sheath with shock-protected sensor as single or twin resistance thermometer

More information

Instruction Manual. LD/LA Level Transmitter. Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY Fax

Instruction Manual. LD/LA Level Transmitter. Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY Fax Instruction Manual Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY 12072 1-800-833-0081 Fax 518-922-8997 www.andinst.com Instrument Model Number Instrument Serial Number LD/LA Level Transmitter

More information

Electromagnetic Flowmeter Hygienic/Sanitary

Electromagnetic Flowmeter Hygienic/Sanitary MagMaster Electromagnetic Flowmeter Hygienic/Sanitary Specification DataFile Unrivalled, fully traceable flow performance, ±0.2% accuracy. Operable flow range: 000 : ensures precise revenue measurement;

More information

FICHA TÉCNICA DE PRODUTO

FICHA TÉCNICA DE PRODUTO FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HMI Automação e Instrumentação, Lda. Rua dos 5 Caminhos, nº 570 4780-382 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 850 501 Fax. +351 300 013 487 Email:

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

Technical Information Memosens CLS82D

Technical Information Memosens CLS82D TI01188C/07/EN/03.16 71318348 Products Solutions Services Technical Information Memosens CLS82D Hygienic conductivity sensors, digital with Memosens technology, cell constant k = 0.57 cm -1 Application

More information

Miniature resistance thermometer Model TR33, thread-mounted

Miniature resistance thermometer Model TR33, thread-mounted Electrical temperature measurement Miniature resistance thermometer Model TR33, thread-mounted WIKA data sheet TE 60.33 Applications Machine building, plant and vessel construction Propulsion technology,

More information

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter Data Sheet D-FMP-10D1475W-Y_4 Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter 10D1475W/Y Flowmeter Systems utilizes a smart microprocessor converter. System accuracy of ±0.5% of

More information

Micro-Change. Cordset Family

Micro-Change. Cordset Family Side Tab Cordset Family Small Space? Big Solution. When space and time are in short supply, look no further than Brad Harrison brand for the best, ready-made m connector solutions. For fast, compact migration

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

RF Capacitance Level Controls

RF Capacitance Level Controls CAC-8A-00-6 681R7 Features and Benefits Reliability Low maintenance costs No moving parts Interface measurement with on/off and continuous output Unaffected by changes in pressure, temperature, specific

More information

Indumax CLS54D. Technical Information

Indumax CLS54D. Technical Information Technical Information Indumax CLS54D Inductive conductivity sensor with hygienic design for applications in the food, beverage and pharmaceutical industries and in biotechnology Application The CLS54D

More information

Amphenol. Advantage. R-Line R-146. Rectangular Attached Multi-Pin Industrial Cable Assemblies. Amphenol - Sine Systems

Amphenol. Advantage. R-Line R-146. Rectangular Attached Multi-Pin Industrial Cable Assemblies. Amphenol - Sine Systems Amphenol Rectangular Attached Multi-Pin Industrial Assemblies Advantage R-146 R-Line Amphenol - Sine Systems Advantage * vs. the R-Line Molded Advantage Series * Patents pending Low Cost UL & CSA Listed

More information

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL Mid-West Instrument BULLETIN NO. ELEC-IM140/11A Replaces ELEC-IM140-141/09A ELECTRICAL Gauges with switches have one or two SPST or SPDT hermetically sealed adjustable set point reed switch assemblies.

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

Model Q40CT. System Features. Toroidal Conductivity Monitor...

Model Q40CT. System Features. Toroidal Conductivity Monitor... ATI s Model Q40CT toroidal conductivity system is designed for on-line monitoring of chemically aggressive process solutions. This blind, analog version is ideally suited for applications where reliable

More information

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output. GENERAL INFORMATION T6000 SERIES TRANSDUCER Electro-Pneumatic (I/P, E/P) APPLICATIONS The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional

More information

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction

More information

Valve Island with Electronic I/O

Valve Island with Electronic I/O Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication

More information

Ashcroft Digital Pressure Gauges

Ashcroft Digital Pressure Gauges TRANSDUCERS/ Ashcroft Digital Pressure Gauges 4 /2" Digit Display, /2" Character Height Maximum Pressure Indication Selectable Engineering Units Chemical Resistant Case Optional Weatherproof Boot The D005PS

More information

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance DREXELBROOK A Leader In Level Measurement Solutions IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements TDR Level Measurement Easy to install, Easy to use TDR Level Measurement

More information

Technical Information Smartec CLD18

Technical Information Smartec CLD18 TI01080C/07/EN/03.16 71314717 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application Compact measuring

More information

Electro-Magnetic Flowmeters COPA-XE

Electro-Magnetic Flowmeters COPA-XE Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates

More information

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC) THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC) Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic, single-point level controller

More information

Temperature Transmitters - Head Mounted

Temperature Transmitters - Head Mounted XTH Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction

More information

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution P R o D u c T I n F o R m at I o n TDR Level Sensor The clean solution Level sensors The clean solution Product description The is a hygienic level sensor for liquids using TDR technology a process for

More information

RCM DIRECT READING FLOWMETER

RCM DIRECT READING FLOWMETER RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Temperature OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 11 Applications Machine building, plant and vessel construction

More information

Mid-West. Instrument. Model 142 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Mid-West. Instrument. Model 142 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL Mid-West Instrument Model 142 Electrical Installation and Operating Instructions BULLETIN NO. ELEC. IM142/14A Supersedes ELEC. IM142/10A ELECTRICAL Gauges with switches have one or two SPST or SPDT hermetically

More information

7250 Series HR Digital Stik

7250 Series HR Digital Stik Series 7250 Product Manual CONTINUOUS LEVEL CONTROLS 7250 Series HR Digital Stik ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS 1 AUTOMATION & PROCESS TECHNOLOGIES 7250 Series Manual Overview

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Data Sheet

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Data Sheet Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology Tank SLAYER 3-IN-1 Measurement Inherent Accuracy ±1 mm API Temperature Corrected Volumes No Scheduled Maintenance or Recalibration

More information

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output. GENERAL INFORMATION T6000 SERIES TRANSDUCER Electro-Pneumatic (I/P, E/P) APPLICATIONS The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional

More information

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters Class l, Division 1 Group A-D IIC T4 As our products are continuously improved, we reserve the right to make any change in the stated

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar DREXELBROOK A Leader In Level Measurement Solutions IMPULSE Series Guided Wave Radar (TDR) and Volumetric for Total Level Measurements TDR Level Measurement Easy to install, Easy to use TDR Level Measurement

More information

Transmitter. Configuration Code TM01 Series 440 Programmable RTD Temperature Transmitter. Application Areas. Features and Benefits

Transmitter. Configuration Code TM01 Series 440 Programmable RTD Temperature Transmitter. Application Areas. Features and Benefits Configuration Code TM01 Series 440 Programmable RTD Temperature Transmitter The Series 440 programmable RTD temperature transmitter is a 2-wire transmitter with an analog output. It has measurement input

More information

F78MP Series Radar FEATURES AND BENEFITS

F78MP Series Radar FEATURES AND BENEFITS F78MP Series Radar The F78MP Series air radar sensor provides non-contact, continuous level measurement for bulk materials in bins, tanks and silos. Accurate and reliable in difficult environments, the

More information

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics

More information

ST5484E Seismic Velocity 4-20 ma Transmitter Datasheet

ST5484E Seismic Velocity 4-20 ma Transmitter Datasheet ST5484E Seismic Velocity 4-20 ma Transmitter Datasheet OVERVIEW The ST5484E is a self-contained seismic velocity transmitter that incorporates a piezoelectric accelerometer, signal integrator, RMS peak

More information

FC Series Signal Conditioners

FC Series Signal Conditioners FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between

More information

Pressure transmitter For sanitary applications Model SA-11

Pressure transmitter For sanitary applications Model SA-11 Electronic pressure measurement Pressure transmitter For sanitary applications Model SA-11 WIKA data sheet PE 81.80 for further approvals see page 8 Applications For gases, compressed air, vapour, liquids,

More information

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters ll 2G EEx ia llc T6 As our products are continuously improved, we reserve the right to make any change in the stated specifications

More information

Profibus-PA. Profibus-PA. Process Automation. Over-Molded Cables Receptacles Field Wireables Accessories. UL File #: E

Profibus-PA. Profibus-PA. Process Automation. Over-Molded Cables Receptacles Field Wireables Accessories. UL File #: E Profibus-PA Process Automation Over-Molded Cables Receptacles Field Wireables Accessories U File #: E9 PROFIBUS (Process Field Bus) is a standard for field bus communication in automation technology. The

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.

More information

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ). ISO-14001 ISO-9001 SPECIFICATION SHEET CP SERIES 2-WIRE TYPE DO TRANSMITTER Models: DCP-20T FEATURES Rigid aluminium enclosure with free angle mounting. Simple operation offers free range setting, auto-calibration,

More information

SPEED SENSORS SIGNAL CONDITIONERS. Standard & Custom Sensors, Signal Conditioners and Interface Electronics

SPEED SENSORS SIGNAL CONDITIONERS. Standard & Custom Sensors, Signal Conditioners and Interface Electronics for INNOVATIVE SENSOR SOLUTIONS Standard & Custom Sensors, Signal Conditioners and Interface Electronics SPEED SENSORS Magnetic Speed Sensors (Active & Passive) Hall Effect Speed Sensors, GBR (Zero Speed)

More information

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU Level probe Features Assembly Device for hydrostatic pressure measurement in liquids High resistance to overload High-precision, robust ceramic measuring cell with longterm stability Simultaneous level

More information