RT T Rack Mount Test T

Size: px
Start display at page:

Download "RT T Rack Mount Test T"

Transcription

1 RT T Rack Mount Test T Switch ALIATION RT switch assemblies for rack and switchboard mounting permit convenient isolation of switchboard relays, meters and instruments. RT racks allow quick and easy multi-circuit testing by conventional test methods. FT Switches mounted in the RT racks isolate protective relays, meters and equipment, allowing the user to safely service installed equipment without disturbing the system. Features The RT switch assemblies accommodate three FT switches mounted on a 1 wide by. steel mounting panel. Any combination of FT switches may be selected. Steel panels are painted black. onsult the factory for additional colors and heights. Each panel is supplied with the hardware to mount the RT assembly to a 1 rack enclosure. The assembly is equipped with a full-length clear cover over all FT switches. The cover allows the switch handles to be opened or closed when the cover is in place, which is especially important during maintenance and repair of equipment. This cover can be secured with a meter seal or padlock. Once secure, the cover also prohibits access to rack mounting screws. The RT assembly will support an FT style test paddle. Each RT assembly is supplied with a unique clear rear shield to help prevent inadvertant contact with live rear terminals. Specifications The standard RT assembly is rated at volts and amps and meets or exceeds all requirements of ANSI/IEEE Standard..

2 RT T Rack Mount TestT Switch Standard STANDARD ATALOG NUMBER SYSTEM FOR 1 RAK FT R T L L L R R R RT Switch digit FT style switch suffix* Left enter Right * See onfiguration Selection hart. Left to right as viewed from the front. RT Mounting Rack Side & Top View of lastic over

3 RT T Rack Mount TestT Switch Optional onfigurations OTIONAL ATALOG NUMBER SYSTEM FOR 1 RAK FT Left enter Right R T G G 1 FT-1 Rack Terminals connectors *Screw T Stud S anel height rack unit,. rack unit,. X= rack unit, with switches mounted low on panel. rack unit,. olor *ANSI G ANSI A Brush Al B Logo** GE G osition # (As viewed from front) *** Left enter Right = Blank * Denotes standard configuration ** onsult factory for special marking *** See onfiguration selection chart for digit codes

4 OTIONAL RT MOUNTING RAKS Rack Unit Rack Unit Rack Unit (Low) Rack Unit THIS VIEW TYIAL FOR ALL ITEMS Top View (Switch & over) Side View (Switch & over)

5 ONFIGURATION SELETION HART -=URRENT (SHORTING) TOTAL NUMBER FT SWITH =URRENT (NON-SHORTING) SWITH ONFIGURATION 1 V A A B D =OTENTIAL OLES G E F H I J INDIVIDUAL

6 ONFIGURATION SELETION HART T - -* NUMBER FT SWITH L L -T SWITH ONFIGURATION =OTENTIAL =URRENT (NON-SHORTING) -=URRENT (SHORTING) * OLES TOTAL V A A B D E F G H I J L L -T -T -T -T -T -T -T -T -T INDIVIDUAL T T T T T T

7 ONFIGURATION SELETION HART SWITH ONFIGURATION INDIVIDUAL FT SWITH OLES =OTENTIAL =URRENT (NON-SHORTING) -=URRENT (SHORTING) NUMBER TOTAL V A A B D E F G H I J T T R R R R R R R R R R -1 T T T T T T T T T T T T -1 1 T -1-1 T T T T 1 1 T 1 T T 1 1 T T T T T T T T T T T T T T T T 1 1 T T 1 1 T T 1 T T 1 T T T 1 1 T T T T 1 T T -1 1 T T T T T T 1 T T T T T T T T T T T T 1 R R R R R R 1 1 O O O O O O O O O O 1 B R R R R R R -1 1 O O O O O O -1 1 R R R R R R R R R R R R 1 1 T T

8 ONFIGURATION SELETION HART SWITH ONFIGURATION INDIVIDUAL FT SWITH OLES =OTENTIAL =URRENT (NON-SHORTING) -=URRENT (SHORTING) NUMBER TOTAL V A A B D E F G H I J * =OTENTIAL =URRENT, NON-SHORTING =URRENT, SHORTING =SHORT IRUIT WITHOUT JAW OR BLADE AT OSITION "H" =FT-* & FT- AEAR SIMILAR EXET THAT FT- IS SHORT IRUIT WITHOUT JAW OR BLADE AT OSITION "H" Back View

9 Non Standard FT Style Switch Selector Step 1 The Switch body can support 1 to 1 poles in slot marked A through J Enter a letter from the legend. Leave unused slots blank. A B D E F G H I J osition: Example: A B D E F G H I J - - R R - -R Legend =otential, Black T=otential, Red =urrent, Non-shorting, Black - or --- or --- = urrent, Non-shorting, Black R-R, R-R-R, R-R-R-R = urrent, Non-shorting, Red (Note: some functions will require more than one slot in the switch body) olored handles available upon request Step (Optional) If a tie bar is required then check this box and draw a dark heavy line over the poles to be joined. (In the example above positions H, I and J will operate together.) Step Select a cover style lear (installs over open closed switches) Black (installs only over closed switches) Step Select a rear terminal type Screws (Standard) Or Studs Factory Use Only atalog Number Assignment

10 RT T Rack Mount Test T Switch USA, anada, Asia, Latin America Tel: Fax: sales.multilin@ge.com Europe, Middle East, Africa Tel: Fax: gemultilin.euro@ge.com RT Switch lease refer to our website for more detailed contact information SA Rev. 1/

SEALED, ILLUMINATED ROCKER SWITCHES

SEALED, ILLUMINATED ROCKER SWITCHES K/K LOW OST, ROKER FOR WET & DUSTY ENVIRONMENTS The K series rockers are rugged, high performance sealed switches designed for use under severe conditions found in marine, appliance, heavy equipment and

More information

! CAUTION D TABLE 1

! CAUTION D TABLE 1 Volts Line to Line 120 208 120 TABLE 1 (I L V LL ) 3 (single phase watts) Range Taps 20-120 20-30- 40-60- 80-100- 120 100-600 100-150- 200-300- 400-500- 600 35-200 35-50- 70-100- 140-175- 200 175-1000

More information

Ambient Level Controller

Ambient Level Controller Ambient Level Controller Installation and Use Manual Issue 1, October 1999 1999 Bogen Communications, Inc. All rights reserved. 54-2028-01 9910 Model: LUALC PEC Code: 5335-621 COM Code: 408184273 Select

More information

Video Data Power. HubWayEXP. UL Listed Sxteen (16) Channel UTP Power Injector. Installation Guide Z1409. More than just power. TM. Rev.

Video Data Power. HubWayEXP. UL Listed Sxteen (16) Channel UTP Power Injector. Installation Guide Z1409. More than just power. TM. Rev. HubWayEXP UL Listed Sxteen (16) Channel UTP Injector Installation Guide Z1409 Rev. 011810 More than just power. TM Overview: Altronix HubWayEXP UTP Injector supplies power combined with pass-through video

More information

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

AMPINNERGY Modular Power Distribution Products

AMPINNERGY Modular Power Distribution Products AMPINNERGY Modular Power Distribution Products Power Distribution Product overage* Tyco Electronics warrants that all AMPINNERGY power distribution system products within this catalog will be delivered

More information

DIN Thermocouple Conditioner MODEL 5M14(V)

DIN Thermocouple Conditioner MODEL 5M14(V) 5M14 1.A.0.5M14 DIN Thermocouple Conditioner MODEL 5M14(V) QUAD ISOLATED THERMOCOUPLE CONDITIONER Module 1 GENERAL DESCRIPTION AND SPECIFICATIONS The Model 5M14(V) is a precision conditioner designed for

More information

Standards. n Built in accordance with NEMA, ANSI, UL and CSA standards

Standards. n Built in accordance with NEMA, ANSI, UL and CSA standards Buck-Boost 9 0 VA to 10 Applications n A comprehensive line of transformers for low voltage applications. n Economical for stepping voltages up or down n Solve over/under voltage problems efficiently n

More information

Specification for Lightning Sensor

Specification for Lightning Sensor Specification for Lightning Sensor Patent Pending November 24. 2003 Content: 1. General description 2. Functional description 3. Electrical connections. 4. Electrical specifications. 5. Mechanical specifications.

More information

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

ETC Installation Guide

ETC Installation Guide ETC Installation Guide Unison Using this Guide This document is intended to guide you through the installation of the DRd Semi-Recessed installation kit. Reference the Unison DRd Rack Enclosure Installation

More information

DST-2000C. Direction Sensing Tachometer INSTRUCTION MANUAL

DST-2000C. Direction Sensing Tachometer INSTRUCTION MANUAL DST-2000C Direction Sensing Tachometer INSTRUCTION MANUAL Azonix-Dynalco, 3690 N. W. 53 Street, Ft. Lauderdale, FL 33309 U.S.A.! (954) 739-4300 Fax (954) 484-3376 www.dynalco.com mailbox@dynalco.com October

More information

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE PAGE 262400-1 SECTION 262400 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

C-Series. Circuit Breaker.

C-Series. Circuit Breaker. -Series ircuit Breaker The -Series hydraulic/magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available in

More information

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Frequency Input 5B45 / 5B46 FEATURES Isolated Frequency Input. Amplifies, Protects, Filters, and Isolates Analog Input. Generates an output of 0 to +5V proportional to input frequency. Model

More information

T S 15KVA 1PH 240/480 Transformer

T S 15KVA 1PH 240/480 Transformer 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T2535173S 15KVA 1PH 240/480 Transformer Acme Electric Catalog Number Manufacturer Description Weight per unit Product

More information

3.0 CHARACTERISTICS. Type CKO Overcurrent Relay. switch, which allows the operation indicator target to drop.

3.0 CHARACTERISTICS. Type CKO Overcurrent Relay. switch, which allows the operation indicator target to drop. 41-101.3A Type CKO Overcurrent Relay switch, which allows the operation indicator target to drop. The front spring, in addition to holding the target, provides restraint for the armature and thus controls

More information

MSP-DCCPGTU Large Screen Tilt Display Mount

MSP-DCCPGTU Large Screen Tilt Display Mount INSTALLATION INSTRUCTIONS Large Screen Tilt Display Mount The Large Screen Tilt Display Mount is a quick disconnect mounting solution for large flat panel displays. The mount features infinite adjust ability

More information

YL SERIES RELAY LATCH DC COIL 4PDT, LOW LEVEL TO 5 AMP

YL SERIES RELAY LATCH DC COIL 4PDT, LOW LEVEL TO 5 AMP Magnetic latch operation All weld construction Contact arrangement 4 PDT Qualified to MIL-PRF-6106 PRINCIPLE TECHNICAL CHARACTERISTICS Applicable sockets: SO-1066-001 SM-1002-003 Contacts rated at Low

More information

A-E01D1. Austin E-Cap Series Isolation Transformer

A-E01D1. Austin E-Cap Series Isolation Transformer Installation Instructions for A-E01D1 Austin E-Cap Series Isolation Transformer Dual Winding Multi-Voltage Revised Nov. 17, 2004 Austin Insulators Inc. 7510 Airport Road Mississauga, Ontario L4T 2H5, CANADA

More information

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION SECTION 16715 COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION PART 1 - GENERAL 1.01 SECTION DESCRIPTION AND BASIC REQUIREMENTS A. The Electrical Power Distribution System provides power distribution from

More information

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5 SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5 Phone: (905) 564-0801 Fax: (905) 564-0806 www.telecor.com E:\T2-108\T2-M108-ABC\T2-M108-B.doc/AD

More information

Classic Series Public Address Amplifiers C10 & C20 Models

Classic Series Public Address Amplifiers C10 & C20 Models Classic Series Public Address Amplifiers C10 & C20 Models Installation and Use Manual 2009 Bogen Communications, Inc. All rights reserved. Specifications subject to change without notice. 54-5978-01B 0901

More information

Series 8 Mark II. Universal Vertical Band Saw

Series 8 Mark II. Universal Vertical Band Saw Series 8 Mark II Universal Vertical Band Saw Capacity 18 x 22 Marvel Series 8 Mark II Universal Tilt-Frame Vertical Band Saw The Marvel Series 8 Mark II has a capacity of 18 x 22 (18 diameter round) with

More information

Window Guards. Retail Buyers Guide

Window Guards. Retail Buyers Guide Window Guards Retail Buyers Guide Add safety and security to any window. John Sterling Window Guards help protect children and pets from window falls while keeping intruders out. Each of the window guard

More information

CIS400. Two-Way Ceiling Monitor CIS400 TWO-WAY CEILING MONITOR FEATURES APPLICATIONS

CIS400. Two-Way Ceiling Monitor CIS400 TWO-WAY CEILING MONITOR FEATURES APPLICATIONS CIS400 TWO-WAY CEILING MONITOR The CIS400 is a complete two-way bassreflex flush-mount loudspeaker assembly designed for fixed installations into typical ceiling plenum spaces. Employing a unique HF waveguide

More information

Digital Lighting Systems, Inc. PD804-DMX. Eight Channel DMX Pack. (includes information for PD804-DMX-S) USER'S MANUAL. PD804-DMX-UM Rev.

Digital Lighting Systems, Inc. PD804-DMX. Eight Channel DMX Pack. (includes information for PD804-DMX-S) USER'S MANUAL. PD804-DMX-UM Rev. , Inc. Eight Channel DMX Pack (includes information for -S) S S S S 4 8 USER'S MANUAL -UM User's Manual - Page GENERAL DESCRIPTION The is an 8-channel DMX- compatible dimmer pack. It contains three printed

More information

LCP128TM Dimming and Switching System

LCP128TM Dimming and Switching System Please ead CP128TM Dimming and Switching System Installation Guide Table of Contents Step-by-Step Instructions Page Step 1: Panel Dimensions...............................................................4

More information

Temperature References for Highest Accuracy Industrial Thermocouple Measurements

Temperature References for Highest Accuracy Industrial Thermocouple Measurements Publication #531 Temperature References for Highest Accuracy Industrial Thermocouple Measurements Obtaining high-accuracy thermocouple temperature measurements requires instrumentation designed to minimize

More information

Power Processor - Series 700F 10KVA to 150KVA

Power Processor - Series 700F 10KVA to 150KVA Power Processor - Series 700F 10KVA to 150KVA Power Conditioning and Regulation for Commercial & Industrial Equipment General Specifications PART 1 - GENERAL 1.1 DESCRIPTION This specification defines

More information

CEC VIBRATION TRANSMITTER

CEC VIBRATION TRANSMITTER CEC 1-808 VIBRATION TRANSMITTER Operation & Maintenance Manual 746 Arrow Grand Circle Covina, CA 91722 United States of America Tel: (626) 938-0200 Fax: (626) 938-0202 Internet: http://www.cecvp.com E-mail:

More information

Safety cable 5.00 (127) Ø5.50 (140) N Narrow 14 M Medium 30 W Wide 40 V Very Wide 70. N Narrow 14 M Medium 30 W Wide 40 V Very Wide 70

Safety cable 5.00 (127) Ø5.50 (140) N Narrow 14 M Medium 30 W Wide 40 V Very Wide 70. N Narrow 14 M Medium 30 W Wide 40 V Very Wide 70 VF100 Bullseye Series - 8121 Trim ROUND ADJUSTABLE AENT DOWNLIGHT 1-LIGHT TRIMMED LED MEDIUM PROJET 8121 TYPE ATALOG NUMBER ROUND GIMBAL ADJUSTABLE TRIMMED AENT - VF100 Series recessed downlight and housing

More information

IB6 Series Solid-State Isolation Relay

IB6 Series Solid-State Isolation Relay IB6 Series Solid-State Isolation Relay Installation & Operation Manual TRANSDATA, INC. 2560 TARPLEY ROAD CARROLLTON, TEXAS 75006 TEL (972) 418-7717 FAX (972) 418-7774 Website: www.transdatainc.com E-mail:

More information

SECTION ELECTRICAL IDENTIFICATION

SECTION ELECTRICAL IDENTIFICATION SECTION 16075 ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Linearized 4-Wire RTD Input 5B35 FEATURES Single-channel signal conditioning module that Amplifies, Protects, Filters, and Isolates Analog Input. Isolates and protects a wide variety of four-wire

More information

Active UTP Transceiver Hub Installation Guide

Active UTP Transceiver Hub Installation Guide Active UTP Transceiver Hub Installation Guide Models Include: HubWayLDH8 HubWayLDH16 - UL Listed eight (8) Channels - UL Listed sixteen (16) Channels Rev. 032108 More than just power. TM Overview: Altronix

More information

1M122A Transformer Parallel Control System

1M122A Transformer Parallel Control System Technical Bulletin 1M122A Transformer Parallel Control System Features CONTROL SYSTEM FEATURES Simple system wiring Scaleable up to 4 transformers Flexible control configuration Set transformers in any

More information

PICO-AMP Miniature Remote Sensing System

PICO-AMP Miniature Remote Sensing System PICO-AMP Miniature Remote Sensing System MD14 Modulated Amplifer and Ultra-small Remote Sensors PICO-AMP Features Ultra-small remote sensors to fit the tightest locations Three fixed frequency selections

More information

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW Isolated, Linearized Thermocouple Input 5B47 FEATURES Isolated Thermocouple Input. Amplifies, Protects, Filters, and Isolates Thermocouple Input Works with J, K, T, E, R, S, and B-type thermocouple. Generates

More information

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A. 3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2 (Code 7 71 071 to 7 71 083) INSTRUCTION MANUAL ( M 981 200 / 00 A ) (c) CIRCUTOR S.A. ----- MKT- MKT2 - ELECTRONIC METERS -------- M-981 200 --- Page Nº 2 3

More information

Gravity Roller Conveyors Service Parts and Assembly Manual

Gravity Roller Conveyors Service Parts and Assembly Manual Gravity Roller Conveyors Service Parts and Assembly Manual 8- Rev A Table of Contents Replacement Parts General Safety Information............................. This Page 0 Gravity Roller Conveyor......................................

More information

Short form User Manual

Short form User Manual Nortech Detection Pty Ltd Unit1, Bldg 5, Forest Central Business Park, 49 Frenchs Forest Road, Frenchs Forest NSW 2086 PO Box 6011, Frenchs Forest DC, NSW 2086 Tel: 02 8977 4047 Fax: 02 9475 4742 email:

More information

PRODUCT FOR HIGH VOLTAGE APPLICATION. Current transformers for Gasinsulated. Instructions for installation, use and maintenance

PRODUCT FOR HIGH VOLTAGE APPLICATION. Current transformers for Gasinsulated. Instructions for installation, use and maintenance PRODUCT FOR HIGH VOLTAGE APPLICATION Current transformers for Gasinsulated switchgear type ELK Instructions for installation, use and maintenance 2 CURRENT TRANSFORMERS FOR GAS-INSULATED SWITCHGEAR TYPE

More information

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

TBX-1329 AC/DC COUPLING TERMINAL BLOCK INSTALLATION GUIDE TBX-1329 AC/DC COUPLING TERMINAL BLOCK Introduction This guide describes how to install and use the TBX-1329 AC/DC coupling terminal block with the SCXI-1120, SCXI-1120D, and SCXI-1121

More information

Window Guards. Add safety and security to any window.

Window Guards. Add safety and security to any window. Window Guards Add safety and security to any window. John Sterling Window Guards help protect children and pets from window falls while keeping intruders out. Each of the window guard series has solid

More information

Warehouse Stock Transformers

Warehouse Stock Transformers Warehouse Stock s Warehouse Stock Buck-Boost Application Description and The Buck-Boost has four separate windings, two-windings in the primary and two-windings in the secondary. The unit is designed for

More information

TECHNICAL PRODUCT DATASHEET

TECHNICAL PRODUCT DATASHEET FORM-ENG-0018 REV A 06-02-03 ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 SUITABLE FOR OEM DISTRIBUTION ONLY TECHNICAL PRODUCT DATASHEET High Density PDM 21 Output / 10

More information

American Electrical Institute

American Electrical Institute American Electrical Institute Oregon Electricians Continuing Education Grounding & Bonding (Article 250) 4 Hours American Electrical Institute PO Box 31131 Spokane, WA 99223 www.aeitraining.com Article

More information

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class GE Ventilated Dry-Type Transformers Secondary Substation Transformers - 5 and 15kV Class GE ventilated dry-type transformers are designed for indoor or outdoor applications in schools, hospitals, industrial

More information

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection: Utility Systems Technologies, Inc. Sag Fighter TM Deep Voltage Sag Protection: D e e p Vo l t a g e S a g P r o t e c t i o n For three phase application: Q u a l i t y P o w e r. B e t t e r B u s i n

More information

MSP-DCCPGSU Large Screen Static Display Mount

MSP-DCCPGSU Large Screen Static Display Mount INSTALLATION INSTRUCTIONS Large Screen Static Display Mount The Large Screen Static Display Mount () is a quick disconnect mounting solution for large flat panel displays. The mount self-adjusts for the

More information

Stainless Steel Continuous Hinges

Stainless Steel Continuous Hinges TABLE OF CONTENTS A ANSI Standards...2 C Cancellation Notification... 2 Concealed Electric Through-Wire... 4-5 Custom Hole Pattern... 2 Custom Length Hinges... 2 D Dutch Door Hinges... 3 E Electrical Modifications

More information

Enclosures. End Configuration Options

Enclosures. End Configuration Options Style MicroPak xtruded base with slide-in flat panel nclosures Technical Data W/AX DOUMNT nd onfiguration Options nd Panel / Thinline ezel: Two piece. Aluminum panel recessed into molded bezel. Page 4

More information

Wall Mount Kit for Elo IDS-02 Series IDS Displays

Wall Mount Kit for Elo IDS-02 Series IDS Displays Quick Installation Guide Wall Mount Kit for Elo IDS-02 Series IDS Displays Revision B P/N UM600076 Safety Warning: Do not install this equipment on any wall or structure that is not capable of supporting

More information

F Series SINGLE-PHASE DIGITAL SWITCHBOARD MONITORS FVA, FVD, FAA, FAD, FF, FT MODELS

F Series SINGLE-PHASE DIGITAL SWITCHBOARD MONITORS FVA, FVD, FAA, FAD, FF, FT MODELS F Series SINGE-PHASE DIGITA SWITCHBOARD MONITORS FVA, FVD, FAA, FAD, FF, FT MODES User's Manual Revision 1.9 September 22, 2017 e Electro Industries/GaugeTech 1800 Shames Drive Westbury, New York 11590

More information

Smart-UPS RT. Isolation Transformer Models: SURT001 and SURT002 Isolation and Step-Down Transformer Models: SURT003 and SURT004.

Smart-UPS RT. Isolation Transformer Models: SURT001 and SURT002 Isolation and Step-Down Transformer Models: SURT003 and SURT004. Smart-UPS RT Isolation Transformer Models: SURT001 and SURT002 Isolation and Step-Down Transformer Models: SURT003 and SURT004 User Manual 990-1673A, English, 11/2003 General Information General Information

More information

SERIES KC RELAY NONLATCH 3PDT, 25 AMP

SERIES KC RELAY NONLATCH 3PDT, 25 AMP All welded construction Contact arrangement 3 PDT configuration in one inch cube Qualified to MIL-PRF-83536 PRINCIPLE TECHNICAL CHARACTERISTICS Applicable sockets: SO-1057-8912 Contacts rated at 28 Vdc;

More information

19" EIA Wall Mount Swing Rack Installation Instructions

19 EIA Wall Mount Swing Rack Installation Instructions 19" EIA Wall Mount Swing Rack Installation Instructions WeRackYourWorld.com 1-866-TRY-GLCC (879-4522) PREFACE This manual is provided to prevent service personnel from committing an act that results in

More information

Drawings and Specifications

Drawings and Specifications Single-Tier Wallmount/Free Standing A C Two-Tier Wallmount/Free Standing B RT-2 Standar d power cor d location. Standard switch location. Standard power cord location. (attach to wall - screws not included)

More information

OPERATION AND MAINTENANCE HANDBOOK D407270XA

OPERATION AND MAINTENANCE HANDBOOK D407270XA OPERATION AND MAINTENANCE HANDBOOK D407270XA vers. 1.0 Thank you for choosing one of Silca s high quality key cutting machines. This machine has been designed, tested and produced in our factory using

More information

HITEK POWER OL3000 SERIES

HITEK POWER OL3000 SERIES 3KW HIGH VOLTAGE POWER SUPPLY The HiTek Power OL3000 series range of single output high voltage power supplies was designed as a component power supply for use in a wide range of diverse applications;

More information

User's Manual: Series 250T AC Current Input (External Sensor) Two-Wire Transmitters

User's Manual: Series 250T AC Current Input (External Sensor) Two-Wire Transmitters User's Manual: Series 250T AC Current Input (External Sensor) Two-Wire Transmitters Table of Contents Page INTRODUCTION: Introduction 1 Description 1 Specifications 2 Specifications (Display Option) 4

More information

Line Terminating Unit P/N:

Line Terminating Unit P/N: Document No. 10860038 Rev. D Line Terminating Unit P/N: 108600 Eurocom D/1 Interface A/ To Eurocom D/1 Interface Tactical ommunications System EOW 24 VD 512 256 1024 OFF 2048 SYN SYN ERROR POWER Operations

More information

MS Connector: (Voltage or Current Output) Pin No. Extension Cable Function. Wire Color. MS Connector: (Start/Stop or PWM) Wire Color WIRING: + A

MS Connector: (Voltage or Current Output) Pin No. Extension Cable Function. Wire Color. MS Connector: (Start/Stop or PWM) Wire Color WIRING: + A T E M P O S O N I C S L S e r i e s INSTALLATION T E M P O S O N I C S L D W I R I N G 550653 C INTEGRAL CABLES: INTEGRAL CABLES WITH HANGING MS CONNECTOR: R Cable w/pigtail Termination: (Voltage or Current

More information

DC200A Displacement Clipper User Manual

DC200A Displacement Clipper User Manual Trig-Tek DC200A Displacement Clipper User Manual Publication No. 980981 A Inc. 4 Goodyear, Irvine, CA 92618 Tel: (800) 722-2528, (949) 859-8999; Fax: (949) 859-7139 atsinfo@astronics.com atssales@astronics.com

More information

P3-HSI High Speed Isolated Sinking/Sourcing Input

P3-HSI High Speed Isolated Sinking/Sourcing Input To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from area to

More information

Maintenance Manual. Simulcast Interface Panel 19D904009G5 & G4. ericssonzy LBI TABLE OF CONTENTS

Maintenance Manual. Simulcast Interface Panel 19D904009G5 & G4. ericssonzy LBI TABLE OF CONTENTS Maintenance Manual Simulcast Interface Panel 19D904009G5 & G4 TABLE OF CONTENTS EDACS Interface Module 1... EDACS Serial Module... PTT Module... Power Monitor For Simulcast... TUAI Module/Simulcast TX

More information

Q-Tech. Q-Tech Commercial Series QTA 1360P/1480P Power Amplifiers. User Manual

Q-Tech. Q-Tech Commercial Series QTA 1360P/1480P Power Amplifiers. User Manual Q-Tech Power Amplifiers WARNING THIS APPLIANCE MUST BE EARTHED General Installation DO NOT run unbalanced high impedance microphone cables near mains, data, telephone or 70/100V line cables. DO NOT run

More information

GRILLE AND REGISTER OPTIONS AND ACCESSORIES

GRILLE AND REGISTER OPTIONS AND ACCESSORIES GRILLE ND REGISTER OPTIONS ND CCESSORIES PRODUCT OVERVIEW OPTIONS ND CCESSORIES FOR FSTENING ND MOUNTING FRMES Up to four methods of fastening available for most models. Sub-frame available for professionally

More information

Source Four 19. Ellipsoidal Series. Source Four. Connector Designation

Source Four 19. Ellipsoidal Series. Source Four. Connector Designation Source Four 19 S p E C I F I C A T I O N S physical Rugged, die cast aluminum construction Rotating shutter assembly ±25 20 gauge stainless steel shutters in a tri-plane assembly Interchangeable lens tubes

More information

P2 H2 NAMEPLATE 6 HOLES M8-10 M SCREW S1 1S2 1S3 X1 X2 X3 PARALLEL HIGH RATIO

P2 H2 NAMEPLATE 6 HOLES M8-10 M SCREW S1 1S2 1S3 X1 X2 X3 PARALLEL HIGH RATIO TYPE : K52 INSULATION LEVEL : up to 24/50/125kV PRIMARY CURRENT : up to 0A up to 0A single 1 to 2 secondary cores 226 M10 205 30 2 225 30 210 20 80 65,5 6 HOLES M8-10 4 Additional MTG base 2 270 4 HOLES

More information

Austin AUSTIN ISOLATION TRANSFORMER (DUAL WINDING SERIES) Installation Instructions for

Austin AUSTIN ISOLATION TRANSFORMER (DUAL WINDING SERIES) Installation Instructions for Austin Installation Instructions for AUSTIN ISOLATION TRANSFORMER (DUAL WINDING SERIES) Austin Insulators Inc. 70 Airport Road Mississauga, Ontario LT H, CANADA tel: (90) 0-; fax: (90) 0-0 e-mail: support@austin-insulators.com

More information

AN EXAMPLE OF A STANDARD ARC FLASH PPE LABELING STRATEGY

AN EXAMPLE OF A STANDARD ARC FLASH PPE LABELING STRATEGY The Electrical Power Engineers Qual-Tech Engineers, Inc. 201 Johnson Road Building #1 Suite 203 Houston, PA 15342-1300 Phone 724-873-9275 Fax 724-873-8910 www.qualtecheng.com AN EXAMPLE OF A STANDARD ARC

More information

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS Acme offers a large selection of Dry-Type Distribution Transformers. Ranging from 600 Volt and below, in both Single and Three Phase, you re sure to find

More information

Maintenance Manual INTERNAL BATTERY STANDBY CHARGER OPTION BC01 (9669), 9670 AND 9771 (FOR MASTR II STATIONS) Mobile Communications LBI-30869L

Maintenance Manual INTERNAL BATTERY STANDBY CHARGER OPTION BC01 (9669), 9670 AND 9771 (FOR MASTR II STATIONS) Mobile Communications LBI-30869L L Mobile Communications INTERNAL BATTERY STANDBY CHARGER OPTION BC01 (9669), 9670 AND 9771 (FOR MASTR II STATIONS) Printed in U.S.A. Maintenance Manual TABLE OF CONTENTS Page DESCRIPTION...................................................

More information

MODEL 3810/2 Line Impedance Stabilization Network

MODEL 3810/2 Line Impedance Stabilization Network EMC TEST SYSTEMS FEBRUARY 1996 REV C PN 399197 MODEL 3810/2 Line Impedance Stabilization Network OPERATION MANUAL USA P.O. Box 80589 Austin, Texas 78708-0589 2205 Kramer Lane, Austin, Texas 78758-4047

More information

AMPSEAL* Automotive Plug Connector and Header Assembly

AMPSEAL* Automotive Plug Connector and Header Assembly AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 114-16016 17 APR 14 NOTE NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Unless

More information

Tarheel Antennas, Inc.

Tarheel Antennas, Inc. Tarheel Antennas, Inc. Instruction Manual for the Model 75A "Stubby" Continuous Coverage HF Antenna PROUDLY MADE IN THE UNITED STATES OF AMERICA 18511 CR 304 St. Joseph, MO 64505 816-671-9409 / 816-364-2619

More information

S&C Series 2000 Circuit-Switchers Outdoor Transmission (69 kv through 230 kv)

S&C Series 2000 Circuit-Switchers Outdoor Transmission (69 kv through 230 kv) Outdoor Transmission (69 kv through 230 kv) Detailed Functional Specification Guide 1.0 GENERAL 1.01 The circuit-switcher shall conform to the following specification. 1.02 The circuit-switcher shall be

More information

SECTION PANELBOARDS

SECTION PANELBOARDS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 24 16 PANELBOARDS SPEC WRITER NOTE: Delete between // --- // if not applicable to project. Also, delete any other item or paragraph not applicable in the section

More information

Jefferson Electric Inc Product Catalog JE901

Jefferson Electric Inc Product Catalog JE901 Jefferson Electric Inc Product Catalog JE901 Worldwide Products and Services Tradition of Excellence Jefferson Electric has been a pioneer and innovator of magnetic products since 1915. We enjoy a rich

More information

POWER LINE IMPEDANCE STABLIZATION NETWORK (LISN) MODEL PLISN-25/2. 5 khz 1 GHz

POWER LINE IMPEDANCE STABLIZATION NETWORK (LISN) MODEL PLISN-25/2. 5 khz 1 GHz INSTRUCTION MANUAL POWER LINE IMPEDANCE STABLIZATION NETWORK (LISN) MODEL PLISN-25/2 5 khz 1 GHz INSTRUCTION MANUAL THIS INSTRUCTION MANUAL AND ITS ASSOCIATED INFORMATION IS PRO- PRIETARY. UNAUTHORIZED

More information

USER MANUAL. Maxwell Technologies BOOSTCAP Ultracapacitor Energy Storage Modules for Low Duty Cycle Applications

USER MANUAL. Maxwell Technologies BOOSTCAP Ultracapacitor Energy Storage Modules for Low Duty Cycle Applications USER MANUAL Maxwell Technologies BOOSTCAP Ultracapacitor Energy Storage Modules for Low Duty Cycle Applications Models: BMOD0125 P064 B02 BMOD0094 P075 B02 Document #1014204 Notice: The products described

More information

NORTH AMERICAN STEEL INNOVATIVE STORAGE SOLUTIONS OUR S T R E N G T H IS OUR PEOPLE NORTH AMERICAN RACK

NORTH AMERICAN STEEL INNOVATIVE STORAGE SOLUTIONS OUR S T R E N G T H IS OUR PEOPLE NORTH AMERICAN RACK NORTH AMERICAN STEEL INNOVATIVE STORAGE SOLUTIONS OUR S T R E N G T H IS OUR PEOPLE NORTH AMERICAN RACK NORTH AMERICAN RACK North American Rollformed Racking is compatible with Redirack and all major Canadian

More information

1.0 General Description

1.0 General Description 1.0 General Description Figure 1 - Plug-N-Play Noise Blanker for the Collins 75S-1 Series The Collins Noise Blanker is designed to be a Plug-N-Play accessory for the Collins 75S-1 series. The Noise Blanker

More information

Ameritron RCS-10 INTRODUCTION

Ameritron RCS-10 INTRODUCTION Ameritron RCS-10 INTRODUCTION The RCS-10 is a versatile antenna switch designed for 50-ohm systems. It handles high power, and sealed relays offer excellent life and connection reliability. It requires

More information

INSTALLATION MANUAL. CTA-30RK-550 Rack Mount Distribution Amplifier

INSTALLATION MANUAL. CTA-30RK-550 Rack Mount Distribution Amplifier INSTALLATION MANUAL CTA-30RK-550 Rack Mount Distribution Amplifier 1 PACKAGE CONTENTS This package contains: One CTA-30RK-550 Rack Mount Distribution Amplifier One CTA-30RK-550 instruction manual PRODUCT

More information

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality. PART 1: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. 1.02

More information

THE PUBLIC ADDRESS AMPLIFIER SYSTEM WITH FLEXIBILITY BUILT-IN

THE PUBLIC ADDRESS AMPLIFIER SYSTEM WITH FLEXIBILITY BUILT-IN THE PUBLIC ADDRESS AMPLIFIER SYSTEM WITH FLEXIBILITY BUILT-IN The Range... T he Mitre range is now a well-proven group of products.with an excellent track record for reliability, Mitre can accommodate

More information

ETC Installation Guide

ETC Installation Guide Unison Echo Light Sensor Overview The provides light level measurement and lighting control for the connected Echo control system. The sensor measures lighting conditions to maintain a programmed lighting

More information

COPALUM Terminals and Splices (For Solid & Stranded Aluminum or Copper Wire)

COPALUM Terminals and Splices (For Solid & Stranded Aluminum or Copper Wire) Product Facts Bar Crimp Technique Terminals and Splices for aluminum-to-aluminum and aluminum-to-copper stripped wire applications Terminates stripped, stranded and solid (round or rectangular) aluminum

More information

TRUSS WEB ANGLES (TYP) BASE (SHEET 5 & 6) ISOMETRIC VIEW DRILLED SHAFT 12" COLUMN BASE CUTTING DETAIL

TRUSS WEB ANGLES (TYP) BASE (SHEET 5 & 6) ISOMETRIC VIEW DRILLED SHAFT 12 COLUMN BASE CUTTING DETAIL OLUMN TRUSS ONNETION (S 3 & 4) TO TRUSS HORD HORD SLIE ( 10) ANGLES END A TRUSS BAK TRUSS HORD FREE END ANEL 10' SUORT END ANELS (SEE HART BELOW) BOTTOM TRUSS HORD BASE ( 5 & 6) TO OF FINISHED GRADE ISOMETRI

More information

SEL-787-2, -3, -4 Transformer Protection Relay Standard Features

SEL-787-2, -3, -4 Transformer Protection Relay Standard Features SEL-787-2, -3, -4 Transformer Protection Relay Standard Features Protection Phase ifferential Elements Overcurrent reaker Monitoring reaker Failure ardware 6 urrent Inputs Slot Z 2 igital Inputs (I) Slot

More information

HEAVY DUTY BENCH GRINDERS

HEAVY DUTY BENCH GRINDERS HEAVY DUTY BENCH GRINDERS BGC-6 (240153) / BGC-8 (240154) Heavy duty construction for maximum service life CSA electrics for safety and reliability All ball bearing construction Steel wheel covers with

More information

H A 6 6 CHANNEL STEREO HEADPHONE AMPLIFIER INSTALLATION AND OPERATION MANUAL

H A 6 6 CHANNEL STEREO HEADPHONE AMPLIFIER INSTALLATION AND OPERATION MANUAL H A6 6 CHANNEL STEREO HEADPHONE AMPLIFIER INSTALLATION AND OPERATION MANUAL IMPORTANT SAFETY INFORMATION 1. Save the carton and packing material even if the equipment has arrived in good condition. Should

More information

Model BiConiLog Antenna. User Manual

Model BiConiLog Antenna. User Manual Model 3149 BiConiLog Antenna User Manual ETS-Lindgren Inc. reserves the right to make changes to any products herein to improve functioning or design. Although the information in this document has been

More information

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450) INSTALLATION AND OPERATION INSTRUCTIONS

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450) INSTALLATION AND OPERATION INSTRUCTIONS ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) 565-6336 FAX: (450)565-6519 INSTALLATION AND OPERATION INSTRUCTIONS "IS" CHIMNEY TYPE: SIZE: FACTORY BUILT CHIMNEY FOR

More information

8 Ft Wide Enclosure Assembly Guide

8 Ft Wide Enclosure Assembly Guide www.rmfiberglass.com 8 Ft Wide Enclosure Assembly Guide RM Products Ltd 1-800-363-0867 www.rmfiberglass.com Table of Contents 1. Parts and Tools List page 3 2. Hardware page 4 3. Maintenance page 5 4.

More information

G-Series Servomotors. AC Brushless Servomotors. Understanding the G-Series Servomotor Model Numbers

G-Series Servomotors. AC Brushless Servomotors. Understanding the G-Series Servomotor Model Numbers rushless Servomotors G-Series Servomotors ORME s G-series brushless servomotors provide high torque-to-inertia ratios and excellent continuous torque and peak torque performance in a compact design. These

More information

INTER PLANT STANDARD STEEL INDUSTRY

INTER PLANT STANDARD STEEL INDUSTRY INTER PLANT STANDARD STEEL INDUSTRY IPSS SPECIFICATION FOR VIBRATION MEASURING SYSTEM FOR LOW SPEED MACHINES (Second Revision) Corresponding IS does not exist IPSS:2-07-027-11 Formerly: IPSS:2-07-027-97

More information