Digital Lighting Systems, Inc. PD804-DMX. Eight Channel DMX Pack. (includes information for PD804-DMX-S) USER'S MANUAL. PD804-DMX-UM Rev.

Size: px
Start display at page:

Download "Digital Lighting Systems, Inc. PD804-DMX. Eight Channel DMX Pack. (includes information for PD804-DMX-S) USER'S MANUAL. PD804-DMX-UM Rev."

Transcription

1 , Inc. Eight Channel DMX Pack (includes information for -S) S S S S 4 8 USER'S MANUAL -UM

2 User's Manual - Page GENERAL DESCRIPTION The is an 8-channel DMX- compatible dimmer pack. It contains three printed circuit boards, the load driver module (LDM) and two control modules. The LDM is equivalent to eight solid-state relays (SSR's) assembled on a single circuit board. Power is fed to the from two 0 Amp. breakers on the same electrical phase. Each breaker feeds four relays and each relay is rated for a maximum output current of 4 amperes. The LDM is mounted at the bottom of the 's enclosure which also serves as a heat sink. The relays are triggered by low-voltage signals generated by the modules. These signals are optically-isolated by the LDM circuitry from all line voltage elements. A stepdown 0 VAC- transformer on the LDM board supplies power to the modules. DMX- control information is received by the s over a shielded twistedpair cable. Several, PD408-DMX or PD-MDX dimmer packs may be daisy-chained together using standard DMX cables with -pin XLR type connectors. Each has two sets of address selectors which may be set to unique addresses and will occupy the next four DMX control channels beginning with the address selected at the front panel. When two or more units are set to the same address, their respective outputs work in unison, increasing the amount of load that can be controlled by a single DMX channel. Each of the outputs may be independently configured not to dim. In such case, a DMX input value greater than switches its respective output to 00%, else the output remains at 0%. Figure shows a functional block diagram of the. Figure shows a and a -S in a typical installation. DIMMING/SWITCHING - (See Page 8 for more information) A may control a combination of dimmed and switched loads. Eachof the s outputs may be independently configured not to dim. This is achieved using a HARDWARE lock to ensure circuits do not dim. All four outputs controlled by each may be configured not to dim by the installation of a small jumper on the back of the circuit board. This may be done at the factory or in the field. This jumper may be removed to allow the future dimming of those outputs. Please see Page 8 for location of this jumper. Alternatively, the may be ordered as a SWITCH-ONLY unit, the -S. This unit has all the same features as the except that there is no dimming, and there are no chokes installed inside the unit. All other information in this manual is the same for both the and the PD804- DMX-S. 88 NW 8th Street, Miami, Fl. Tel: or Fax: Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A. -UM

3 Figure - Functional Block Diagram LDM J SSR's OPTICAL ISOLATORS Load Driver Module 0 VAC Transformer Triac Triac Triac Triac4 Triac Triac Triac Triac8 NEUTRAL BUS H XLR Type DMX Connectors Load Driver Module Information 4 N N N N4 N N N Table - XLR DMX Connectors Pin Assignment Pin Function Pin No. Ground Shield -DATA +DATA Empty 4 Empty N8 8 H Table - Terminals Definition User's Manual - Page NAME DESCRIPTION Output Of Solid-State Relay # Output Of Solid-State Relay # Output Of Solid-State Relay # 4 Output Of Solid-State Relay #4 Output Of Solid-State Relay # Output Of Solid-State Relay # Output Of Solid-State Relay # 8 Output Of Solid-State Relay #8 H Hot Line Feed For Relays,, & 4 H Hot Line Feed For Relays,, & 8 N-N8 Neutral Bus Connections. Table - Absolute Maximum Electrical Ratings Electrical Characteristic Terminal Maximum Relay Load Current to 8 4 Amps. Input Current For Relays & H 0 Amps. Input Current For Relays & 4 H 0 Amps. Input Voltage H-H 0 VAC, -Phase. 4 4 OUT IN Figure - Typical Installation 4 # AWG Typical To Distribution Panel 4 # AWG Typical To Distribution Panel To Loads To Loads DMX CONTROL EQUIPMENT -S To more DMX Equipment DMX-CC-LEN -Standard DMX Cable with -pin XLR Connectors 88 NW 8th Street, Miami, Fl. Tel: or Fax: Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A. -UM

4 C C Digital Lighting Systems User's Manual - Page 8.0" ( mm) Bottom View / and /4 Conduit Knockouts 4." (0 mm) IN 4 OUT 4 Top View.9" (48 mm).00" ( mm) DMX Ports." ( mm) " ( mm) " ( mm)." ( mm).000" ( mm).00" (8 mm) " ( mm) PD804 ( LDM) Load Driver Module H 4 N N N N N N N N 8 H Front Cover.0" (8 mm) T4 T T T PD804 9 VAC Transformer LED 4 8 # # W W 0 0 T8 T T T PD804." (98 mm) # S ADDRESS SELECTORS S 4 LED OUTPUT MONITORS # S S 4 J J Circuit Legend Microprocessor. Nonvolatile Memory. Communications Chip. 4 Quartz Crystal. Power Supply Capacitor. Voltage Regulator. Signal & Power Connector. 8 Output LED Monitors. S- Address Selectors. S Address Expansion Jumper. Enclosure Installation DMX XLR Connectors Components Side Figure. Enclosure And Circuit Details Solder Side Surface mount the dimmer pack in a well ventilated area where the ambient temperature does not exceed 90 F for full load operation. Allow 4" of side clearance for proper air circulation. Installation clearance shall meet local and/or NEC code requirements. Enclosures may be attached to the wall or other mounting surface by holes in the heat sink flanges. Refer to the drawings above for the proper dimensions. Conduit shall be pulled to the top of the dimmer packs. NOTE The may create a slight buzzing noise and should not be located where this is objectionable. 4 S E D F AB E D AB F S S S Address Expansion Jumper (S) On Solder Side 88 NW 8th Street, Miami, Fl. Tel: or Fax: 0-- " ( mm) 00 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A. S S 8 4 S -UM

5 General Wiring Instructions Wiring Notes DO NOT EXCEED 480 W (4 Amps. ) per dimmer 0VAC. All wiring between the DMX control panel, dimmers, and other DMX equipment is low voltage (NEMA Class ) and may be run with one shielded twisted pair #8 AWG wire. Standard Industry DMX- compatible cables may be used. dimmer packs may be fed by one or two 0 A (maximum) branch circuits and may have up to eight separately dimmed loads. Both breakers must be on the same power phase. CAUTION: DO NOT attempt to parallel outputs to increase capacity. Installations must conform to local and/or NEC code requirements. Each load must have its own Neutral wire for full load operation. All line voltage wires must have copper conductors of adequate Gauge with 90 C wire insulation. POWER EACH LOAD DIRECTLY BEFORE CONNECTING IT TO THE, TO ENSURE PROPER WIRING. Figure 4. Typical 0 VAC Wiring. CAUTION 0 VAC Models ONLY,,,4,,,4 SSR's OPTICAL ISOLATORS LDM Load Driver Module Triac Triac Triac Triac4 0 VAC Transformer Triac Triac Triac Triac8 NEUTRAL BUS H Ground LOAD # LOAD # LOAD # HOT out # 4 4 LOAD #4 N N N N4 N N N N8 LOAD # LOAD # LOAD # HOT out # 8 8 LOAD #8 H HOT out # HOT out # HOT out # HOT out # HOT out # HOT out # Earth Ground ON ON User's Manual - Page 4 Breaker 0 A To Neutral Bus in PD804 board To Neutral Bus in PD804 board Breaker 0 A For Full Load Operation Use: # AWG copper conductor wire for Line & Neutral Feeds. #4 AWG copper conductors in/out to each load. Max. Load per circuit : 4 Amperes (480W at 0 VAC). 88 NW 8th Street, Miami, Fl. Tel: or Fax: 0-- Neutrals To Loads Neutrals To Loads 00 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A. x0 A - 0 VAC Breakers On Same Phase To Breaker Panel Neutral Bus -UM

6 -0 General Wiring Instructions Wiring Notes DO NOT EXCEED 90 Watts (4 Amps) per dimmer output at 40 VAC. All wiring between the DMX control panel, dimmers, and other DMX equipment is low voltage (NEMA Class ) and may be run with one shielded twisted pair #8 AWG wire. Standard Industry DMX- compatible cables may be used. dimmer packs may be fed by one or two 0 A (maximum) branch circuits and may have up to eight separately dimmed loads. Both breakers must be on the same power phase. CAUTION: DO NOT attempt to parallel outputs to increase capacity. Installations must conform to local and/or NEC code requirements. Each load must have its own Neutral wire for full load operation. All line voltage wires must have copper conductors of adequate Gauge with 90 C wire insulation. POWER EACH LOAD DIRECTLY BEFORE CONNECTING IT TO THE, TO INSURE PROPER WIRING. Figure. Typical 0/40 VAC Wiring. CAUTION 0-40 VAC Models ONLY,,,4,,,4 SSR's OPTICAL ISOLATORS LDM Load Driver Module Triac Triac Triac Triac4 0 VAC Transformer Triac Triac Triac Triac8 NEUTRAL BUS H Ground LOAD # LOAD # LOAD # HOT out # 4 4 LOAD #4 N N N N4 N N N N8 LOAD # LOAD # LOAD # HOT out # 8 8 LOAD #8 H HOT out # HOT out # HOT out # HOT out # HOT out # HOT out # Earth Ground ON ON User's Manual - Page Breaker 0 A To Neutral Bus in PD804 board To Neutral Bus in PD804 board Breaker 0 A For Full Load Operation Use: # AWG copper conductor wire for Line & Neutral Feeds. #4 AWG copper conductors in/out to each load. Max. Load per circuit : 4 Amperes (90W at 40VAC). 88 NW 8th Street, Miami, Fl. Tel: or Fax: 0-- Neutrals To Loads Neutrals To Loads x0 A - 0/40 VAC Breakers On Same Phase 00 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A. To Breaker Panel Neutral Bus -UM

7 User's Manual - Page Figure. -4/ Low Voltage Load and Power Wiring,,,4,,,4 NOTES CAUTION -4 - Models ONLY SSR's OPTICAL ISOLATORS LDM Load Driver Module Triac Triac Triac Triac4 0 VAC Transformer Triac Triac Triac Triac8 NEUTRAL BUS H LOAD # LOAD # LOAD # HOT out # 4 4 LOAD #4 N N N N4 N N N N8 LOAD # LOAD # LOAD # HOT out # 8 8 LOAD #8 H HOT out # HOT out # HOT out # HOT out # HOT out # HOT out # Electrical Distribution Panel NEUTRAL X PRIMARY SECONDARY With -4 you may use a single 4 VAC-800 VA or better transformer or two separate 4 VAC-400 VA or better transformers. With - you may use a single VAC-400 VA or better transformer or two separate VAC-00 VA or better transformers. Follow transformer's installation & wiring instructions from manufacturer. 4 Maximum Load Per Output: 48 Watts at VAC. Maximum Load Per Output: 9 watts at 4 VAC. ON X4 For Full Load Operation Use: # AWG copper conductor wire for Line & Neutral Feeds. #4 AWG copper conductors in/out to each load. Max. Load per circuit : 4 Amperes (9W at 4 VAC). 88 NW 8th Street, Miami, Fl. Tel: or Fax: 0-- X X4 X 00 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A. -UM

8 4 8 S S Digital Lighting Systems User's Manual - Page DMX Address Setting Up to 8 -DMX boards (two in each, one in each PD408/PD-DMX) may be installed in any one system. Their DMX inputs should be daisy-chained using standard DMX- cables. Different addresses ranging from to 09 may be selected for each dimmer, depending on which DMX channel(s) will be used to control it. Each uses four consecutive DMX bytes from the input stream beginning at the address selected using rotary selectors S, S and address expansion jumper S. (See Figure on page for selectors location). The is shipped from the factory with jumpers S installed allowing a DMX address range between and to be selected by S & S (See Table 4). For higher addresses (-09) jumper S must be removed (See Table ). Non-Dim Output Setting Any or all of the outputs may be configured for non-dim (switch only) operation. This prevents inadvertent dimming, or damage, of loads that cannot be dimmed, such as contactors, mechanical relays, motors, non-dim fluorescent, etc... Since this procedure involves adding external wire jumpers to the board, it is preferable to have it performed by the factory, at time of order. However, a qualified electronic technician can perform the procedure in the field when necessary. Figure 8 shows the location for installing the non-dim (ND) jumpers. The numbers shown next to the ND jumpers represent the corresponding output number of the. Installing an ND jumper makes the corresponding output non-dim (switch only). A DMX value greater than turns a non-dim output to full intensity. A DMX value of or less turns it fully off. Installation Check List BEFORE ENERGIZING THE MAKE SURE: Loads are tested before connecting to dimmers. Breaker feed lines are on same electrical phase. has been properly grounded. All line voltage screw terminals are properly tightened to prevent hot spots. Low voltage data lines connections are properly insulated. Low voltage data lines polarity is observed throughout the system. The is set to the right addresses. Figure - Address & Mode Selection. Solder (Back) Side ND ND ND ND4 0 Non-Dim Jumpers ND-ND4 Installed Output Is Non-Dim (Switch Only) Removed Normal Dimmer Output. Unit is shipped without ND jumpers. Address Expansion Jumper (S) Installed (S,S) Address Range: - Removed (S,S) Address Range: -09 S Unit is shipped with S Installed. 88 NW 8th Street, Miami, Fl. Tel: or Fax: Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A. -UM

9 Address Selection Information Table 4 - Addresses - User's Manual - Page 8 Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Addr. S S Addr. S S Addr. S S Addr. S S Addr. S S Addr. S S Addr. S S Addr. S S A0 9 C0 E A 94 C E A 9 C E A 9 C 8 E A4 9 C4 9 E A 98 C 0 E A 99 C E A 00 C E A8 0 C8 E A9 0 C9 4 E9 0A 4 A 4A 0 A 9 8A AA 0 CA EA 0B 44 B 4B 08 B 40 8B AB 04 CB EB 0C 4 C 4C 09 C 4 8C AC 0 CC EC 4 0D 4 D 8 4D 0 D 4 8D 4 AD 0 CD 8 ED 0E 4 E 9 4E E 4 8E AE 0 CE 9 EE 0F 48 F 80 4F F 44 8F AF 08 CF 40 EF B0 09 D0 4 F B 0 D 4 F B D 4 F B D 44 F B4 D4 4 F B 4 D 4 F B D 4 F B D 48 F B8 D8 49 F B9 8 D9 0 F9 A 9 A 9 A A 9A 8 BA 9 DA FA 8 B 0 B 9 B 4 B 9B 88 BB 0 DB FB 9 C C 9 C C 9C 89 BC DC FC 0 D D 94 D D 8 9D 90 BD DD 4 FD E E 9 E E 9 9E 9 BE DE FE F 4 F 9 F 8 F 0 9F 9 BF 4 DF FF Table 4 - Decimal to Hexadecimal Address Chart. Address Selection Chart Using S-S with JUMPER INSTALLED 88 NW 8th Street, Miami, Fl. Tel: or Fax: Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A. -UM

10 Address Selection Information Table - Addresses -09 User's Manual - Page 9 Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Addr. S S Addr. S S Addr. S S Addr. S S Addr. S S Addr. S S Addr. S S Addr. S S A0 449 C0 48 E A 40 C 48 E A 4 C 48 E A 4 C 484 E A4 4 C4 48 E A 44 C 48 E A 4 C 48 E A 4 C 488 E A8 4 C8 489 E A9 48 C9 490 E9 0A 99 A 4A A 9 8A 4 AA 49 CA 49 EA 8 0B 00 B 4B 4 B 9 8B 48 AB 40 CB 49 EB 9 0C 0 C 4C C 9 8C 49 AC 4 CC 49 EC 0 0D 0 D 4 4D D 98 8D 40 AD 4 CD 494 ED 0E 0 E 4E E 99 8E 4 AE 4 CE 49 EE 0F 04 F 4F 8 F 400 8F 4 AF 44 CF 49 EF B0 4 D0 49 F B 4 D 498 F B 4 D 499 F B 48 D 00 F B4 49 D4 0 F B 40 D 0 F B 4 D 0 F B 4 D 04 F B8 4 D8 0 F B9 44 D9 0 F9 8 A A 4 A 9 A 4 9A 44 BA 4 DA 0 FA 84 B B 48 B 80 B 4 9B 444 BB 4 DB 08 FB 8 C C 49 C 8 C 4 9C 44 BC 4 DC 09 FC 8 D 8 D 0 D 8 D 44 9D 44 BD 48 DD 0 N/A 8 E 9 E E 8 E 4 9E 44 BE 49 DE N/A 88 F 0 F F 84 F 4 9F 448 BF 480 DF N/A Table - Decimal to Hexadecimal Address Chart. Address Selection Chart Using S-S with JUMPER REMOVED 88 NW 8th Street, Miami, Fl. Tel: or Fax: Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A. -UM

11 LIMITED WARRANTY Digital Lighting Systems, warrants to the purchaser that its products have been carefully manufactured and inspected and are warranted to be free from defects of workmanship and materials when used as intended. Any abuse or misuse contrary to normal operation shall void this warranty. Digital Lighting Systems' obligation under this warranty shall be limited to replacement or repair of any units as shall within two years of date of invoice from Digital Lighting Systems, prove defective; and Digital Lighting Systems shall not be liable for any other damages, whether direct or consequential. The implied warranties of merchantability and fitness for a particular purpose are limited to the duration of the expressed warranty. Some states do not allow the exclusion of the limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, you may also have other legal rights which vary from state to state. Upon request, replacement unit(s) will be shipped as soon as available. Unless immediate shipment of replacement merchandise is requested, Digital Lighting Systems will not ship replacement merchandise until defective merchandise is received, inspected, and determined to be defective. No labor charges in connection with warranty problems will be reimbursed by Digital Lighting Systems without prior written approval from the factory. Digital Lighting Systems distributors and representatives have no authority to change this warranty without written permission. Digital Lighting Systems reserves the right to determine the best method of correcting warranty problems. Defective merchandise may be returned to Digital Lighting Systems, prepaid, after prior notification has been given and approval obtained for the return. To obtain prior approval for the return of the defective items, contact your local Digital Lighting Systems distributor, representative, or: Digital Lighting Systems, Inc. Attn: Customer Service Department 88 NW 8th Street Miami, FL (0) 4-89

12 , Inc. 88 NW 8th Street Miami, FL Tel Fax 0-- e-m Printed in U.S.A. May 00

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. PD408-AN0-277 ANALOG 0-0 V 0-0V analog control 4 Channel x 2250 W Dimmer & Switch Packs 220/240/277 Volts operation PD408-AN0-277 4 circuit Analog -0V 4 x 8 A. Dimmer pack Serial Number Digital Lighting

More information

Digital Lighting Systems, Inc. PD402-DMX-RP. DMX512 4 x 300W Reverse Phase dimmer. DMX Address Hexadecimal = [ (S2 x 16) + S1 + 1 ]

Digital Lighting Systems, Inc. PD402-DMX-RP. DMX512 4 x 300W Reverse Phase dimmer. DMX Address Hexadecimal = [ (S2 x 16) + S1 + 1 ] , Inc. MX512 compatible our Channel immer or Switch Pack Reverse Phase 4 x 300 Watts @ 120 VAC MX512 4 x 300W Reverse Phase dimmer MX Address Hexadecimal = [ (S2 x 1) + S1 + 1 ] S2 S1 LOA Output sign wave

More information

PROTOCOL WISH4 & WISH4-RP

PROTOCOL WISH4 & WISH4-RP & -RP Integrated Channel Dimming system -RP Triac dimmers x Amps. Reverse Phase dimmers x.5 Amps. USER'S MANUAL -UM User's Manual - Page GENERAL DESCRIPTION The is a self contained lighting controller

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. , Inc. 24DC 4 Channel MiniFader/ Chaser 4 independent inputs 4 x 5 Amps Voltage range: 6VDC to 24 VDC 4 x 5 Amps outputs Lighting animation controller USER'S MANUAL UM 04/08 General Description User's

More information

Visa Smart Debit/Credit Certificate Authority Public Keys

Visa Smart Debit/Credit Certificate Authority Public Keys CHIP AND NEW TECHNOLOGIES Visa Smart Debit/Credit Certificate Authority Public Keys Overview The EMV standard calls for the use of Public Key technology for offline authentication, for aspects of online

More information

LCP128TM Dimming and Switching System

LCP128TM Dimming and Switching System Please ead CP128TM Dimming and Switching System Installation Guide Table of Contents Step-by-Step Instructions Page Step 1: Panel Dimensions...............................................................4

More information

Contents. Warranty and Disclaimer 2 Introduction 3

Contents. Warranty and Disclaimer 2 Introduction 3 Contents Warranty and Disclaimer 2 Introduction 3 Physical Dimensions Board Layout 4 Usage Using the Relay board 5 Setting the start address 5 Configuration Jumper 6 Using the Relays 7 Using the DMX connectors

More information

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter User Manual UNICOM 2500 Installation Operation Programming Universal Communication Converter UNICOM 2500 Electro Industries/GaugeTech 1800 Shames Drive Westbury, New York 11590 Tel 516.334.0870 Fax 516.338.4741

More information

Contents. Warranty and Disclaimer 2

Contents. Warranty and Disclaimer 2 Contents Warranty and Disclaimer 2 Physical Dimensions Board Layout 3 Usage Using the PWM board 4 Setting the start address 4 Dimming LED s 5,6 Typical hookup 7 Terminator 8 Troubleshooting Ground, termination,

More information

AIU-2 Installation Manual

AIU-2 Installation Manual AIU-2 Installation Manual RESEARCH CONCEPTS INC. 9501 Dice Lane Lenexa, Kansas 66215 USA VOICE: (913) 422-0210 FAX: (913) 422-0211 www.researchconcepts.com support@researchconcepts.com Contents subject

More information

Function Block DIGITAL PLL. Within +/- 5ppm / 10 years (Internal TCXO Stability) 1 External Reference Frequency Range: 10MHz +/- 100Hz

Function Block DIGITAL PLL. Within +/- 5ppm / 10 years (Internal TCXO Stability) 1 External Reference Frequency Range: 10MHz +/- 100Hz Features * Best Suited for Local Oscillator of Microwave Equipment with Low Phase Noise and Low Spurious Emission * Programmable Selection by Rotary Switch or Serial Control Signal * Built-in PLL Circuit

More information

IC800SSD Hardware Manual Pub 348R5. for models. A publication of

IC800SSD Hardware Manual Pub 348R5. for models. A publication of IC800SSD Hardware Manual Pub 348R5 for models IC800SSD104S1A IC800SSD104RS1A IC800SSD107S1A IC800SSD107RS1A IC800SSD407RS1A IC800SSD216S1A IC800SSD216RS1A IC800SSD420RS1A IC800SSD228S1A IC800SSD228RS1A

More information

MaxLite Linear Strip ECO Series

MaxLite Linear Strip ECO Series General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide www.i2systems.com i2systems is a registered trademark of Integrated Illumination Systems, Inc. LightLink is a trademark of Integrated Illumination Systems, Inc. 2018 Integrated Illumination Systems, Inc.

More information

Smart-UPS RT. Isolation Transformer Models: SURT001 and SURT002 Isolation and Step-Down Transformer Models: SURT003 and SURT004.

Smart-UPS RT. Isolation Transformer Models: SURT001 and SURT002 Isolation and Step-Down Transformer Models: SURT003 and SURT004. Smart-UPS RT Isolation Transformer Models: SURT001 and SURT002 Isolation and Step-Down Transformer Models: SURT003 and SURT004 User Manual 990-1673A, English, 11/2003 General Information General Information

More information

Secret Key Systems (block encoding) Encrypting a small block of text (say 128 bits) General considerations for cipher design:

Secret Key Systems (block encoding) Encrypting a small block of text (say 128 bits) General considerations for cipher design: Secret Key Systems (block encoding) Encrypting a small block of text (say 128 bits) General considerations for cipher design: Secret Key Systems (block encoding) Encrypting a small block of text (say 128

More information

Distribution Amplifiers 1

Distribution Amplifiers 1 Distribution Amplifiers 1-30dB PUT 49-750 MHz 43 db GA POWER DOUBLED P/N: 1002705 REVERSE GA M MAX DESCRIPTION The R.L. DRAKE models DA8642, DA8632,, and DA7533, are broadband distribution amplifiers designed

More information

MODEL 3810/2 Line Impedance Stabilization Network

MODEL 3810/2 Line Impedance Stabilization Network EMC TEST SYSTEMS FEBRUARY 1996 REV C PN 399197 MODEL 3810/2 Line Impedance Stabilization Network OPERATION MANUAL USA P.O. Box 80589 Austin, Texas 78708-0589 2205 Kramer Lane, Austin, Texas 78758-4047

More information

Mirage B-320-G FEATURES

Mirage B-320-G FEATURES Mirage B-320-G The Mirage B-320-G is a VHF power amplifier designed for 2 meters covering 144-148 MHz. The Hi and Lo input selector switch makes this amp useable for both handheld and mobile transceivers.

More information

Table of Contents. Safety Notices

Table of Contents. Safety Notices IM0081 2018-01 Table of Contents Product Overview... 3 Principle of Operation... 3 Closed-Loop Servo Control with the FC-24 Controller... 4 Adjustments... 5 LED Status Indicators... 6 Installation...7

More information

USER MANUAL. Opto-Splitters

USER MANUAL. Opto-Splitters Opto-Splitters USER MANUAL TMB 24/7 Technical Support US/Canada: +1 818.794.1286 Toll Free: 1 877.862.3833 (877.TMB.DUDE) UK: +44 (0)20.8574.9739 Toll Free: 0800.652.5418 e-mail: techsupport@tmb.com TABLE

More information

USER MANUAL Table of Contents

USER MANUAL Table of Contents USER MANUAL Table of Contents Safety Information 3 Specifications 4 Main Power Connection 5 DMX-512 Connection 5 Fixture Level 6 Set Up 6 Operation Options 7 Connection 8 Rigging the Fixture 9 Cleaning

More information

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers. INSTALLATION GUIDE VB37M Video Balun Transceiver for Twisted Pair Description Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers. The VB37M

More information

BLD75-1. Bilevel Step Motor Driver. User s Guide. #L010125

BLD75-1. Bilevel Step Motor Driver. User s Guide.   #L010125 BLD75-1 Bilevel Step Motor Driver User s Guide A N A H E I M A U T O M A T I O N #L010125 1 Features Unipolar Operation 10 Amps per Phase Operating Current (Kick Current) 7 Amps per Phase Standstill Current

More information

MBC Bipolar Microstep Driver. User s Guide E. Landon Drive Anaheim, CA

MBC Bipolar Microstep Driver. User s Guide E. Landon Drive Anaheim, CA MBC10641 Bipolar Microstep Driver User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471 website: www.anaheimautomation.com

More information

MS-CEFB Filter Box. Installation Guide

MS-CEFB Filter Box. Installation Guide MS-CEFB Filter Box Magnum Energy, Inc. 2211 West Casino Rd. Everett, WA 98204 Phone: 425-353-8833 Fax: 425-353-8390 Web: http://magnumenergy.com Installation Guide Introduction Introduction The CE Filter

More information

INSTRUCTION MANUAL TIMER -X UNIVERSAL TIMER

INSTRUCTION MANUAL TIMER -X UNIVERSAL TIMER FILE: IM_091-214-12_revA.indd REV: A REVISED BY: thn DATE: 02-22-2013 INSTRUCTION MANUAL TIMER -X UNIVERSAL TIMER (duty cycle, dodo,dopi) picture of product MODEL #091-214-12 INPUT: 12VDC or 110-250 VAC

More information

SERIES 3000 Kilowatt Hour Meter

SERIES 3000 Kilowatt Hour Meter SERIES 3000 Kilowatt Hour Meter INSTALLATION AND OPERATION MANUAL INDEX Short Cut to Resetting the Demand Readings Inside Front Cover Introduction 1. Main Features 2. The Meter Terminals 3. Wiring Diagrams

More information

INSTALLATION GUIDE ET1551U. IP Video Camera Over Single Twisted Wire Ethernet Extender with EtherStretch. Description

INSTALLATION GUIDE ET1551U. IP Video Camera Over Single Twisted Wire Ethernet Extender with EtherStretch. Description INSTALLATION GUIDE ET1551U IP Video Camera Over Single Twisted Wire Ethernet Extender with EtherStretch Description The ET1551U is another component of the NITEK EtherStretch line. This Environmentally

More information

Instruction Manual MTX-8485C MRX-8485C Four Channel Video Multiplexer with Bi-directional Data

Instruction Manual MTX-8485C MRX-8485C Four Channel Video Multiplexer with Bi-directional Data Instruction Manual MTX-8485C MRX-8485C Four Channel Video Multiplexer with Bi-directional Data Copyright 2005, American Fibertek, Inc. 1027JD Table of Contents Functional Description...3 Installation...3

More information

JMAA-3600HR16-UL. Installation and Operation Instructions. Performance Series 360w RMS 4-Channel Amplifier Kit For Harley RoadGlide Ultra

JMAA-3600HR16-UL. Installation and Operation Instructions. Performance Series 360w RMS 4-Channel Amplifier Kit For Harley RoadGlide Ultra Performance Series 360w RMS 4-Channel Amplifier Kit For 2016-2018 Harley RoadGlide Ultra # JMAA-3600HR16-UL 2017 J&M Corporation. All rights reserved. 9/17 Installation and Operation Instructions Product

More information

SONARRAY SR1 SYSTEM INSTRUCTION MANUAL

SONARRAY SR1 SYSTEM INSTRUCTION MANUAL SONARRAY SR1 SYSTEM INSTRUCTION MANUAL SONARRAY SR1 SYSTEM INSTRUCTION MANUAL Introduction Thank you for purchasing the SONARRAY SR1 SYSTEM speakers. When properly installed, these speakers will provide

More information

Installation & User Guide. For Powering Distributed Audio Systems A45-X2 TWO CHANNEL AMPLIFIER

Installation & User Guide. For Powering Distributed Audio Systems A45-X2 TWO CHANNEL AMPLIFIER Installation & User Guide For Powering Distributed Audio Systems TWO CHANNEL AMPLIFIER A45-X2 A45-X2 TWO CHANNEL AMPLIFIER TABLE OF CONTENTS Features...1 Product Overview...2 Package Contents...4 Preparing

More information

INTELLIMETER REGISTER

INTELLIMETER REGISTER INTELLIMETER REGISTER MODEL RG2 INSTALLATION AND CONNECTIONS INSTALLATION MANUAL WARNING: Any work on or near energized metering equipment can present a danger of electrical shock. All work on these products

More information

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE OPERATION & SERVICE MANUAL FOR FC 100 SERIES AC POWER SOURCE FC 110 AC POWER SOURCE VERSION 1.3, April 2001. copyright reserved. DWG No. FC00001 TABLE OF CONTENTS CHAPTER 1 INTRODUCTION... 1 1.1 GENERAL...

More information

745 Transformer Protection System Communications Guide

745 Transformer Protection System Communications Guide Digital Energy Multilin 745 Transformer Protection System Communications Guide 745 revision: 5.20 GE publication code: GEK-106636E GE Multilin part number: 1601-0162-A6 Copyright 2010 GE Multilin GE Multilin

More information

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4. An American Control Electronics Brand PCM4 SERIES PCM4 USER MANUAL www.minarikdrives.com Dear Valued Consumer: Congratulations on your purchase of the PCM4 Series isolation card. This User Manual was created

More information

User Manual. Smart-UPS On-Line. Uninterruptible Power Supply. Isolation Transformer Models: SURT001 and SURT002

User Manual. Smart-UPS On-Line. Uninterruptible Power Supply. Isolation Transformer Models: SURT001 and SURT002 User Manual Smart-UPS On-Line Uninterruptible Power Supply Isolation Transformer Models: SURT001 and SURT002 Isolation and Step-Down Transformer Models: SURT003 and SURT004 General Information Important

More information

S-4VC/S-6VC. For Connecting Four/Six Pairs of Speakers to an Amplifier or Receiver, with Precise Volume Adjustment in any Zone

S-4VC/S-6VC. For Connecting Four/Six Pairs of Speakers to an Amplifier or Receiver, with Precise Volume Adjustment in any Zone INSTALLATION & USER GUIDE For Connecting Four/Six Pairs of Speakers to an Amplifier or Receiver, with Precise Volume Adjustment in any Zone SPEAKER SELECTORS WITH VOLUME CONTROLS S-4VC/S-6VC S-4VC / S-6VC

More information

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC. INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC. MANUAL PART NUMBER 180-0036 ORIGINAL: 1-17-83 REVISION: B (8-26-86) NOT TO BE CHANGED WITHOUT MSHA

More information

VOLUME CONTROL CONNECTION TERMINAL

VOLUME CONTROL CONNECTION TERMINAL INSTALLATION & USER GUIDE For Parallel Signal Distribution to Multiple Volume Controls VOLUME CONTROL CONNECTION TERMINAL V-T8 V-T8 VOLUME CONTROL CONNECTION TERMINAL TABLE OF CONTENTS Features...1 Product

More information

BC145 SIGNAL ISOLATOR BOARD

BC145 SIGNAL ISOLATOR BOARD BC145 SIGNAL ISOLATOR BOARD 4/17 Installation & Operating Manual MN1373 Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check www.baldor.com to download

More information

Broadband Step-Up Transformer. User Manual

Broadband Step-Up Transformer. User Manual Broadband Step-Up Transformer User Manual 990-1930 09/2004 Introduction Introduction About this unit The APC Step-Up Transformer provides 220 V power from 60 VAC Broadband cable systems. Safety Electrical

More information

/01. Western Pacific AA F-3 Set Shell Replacement Instruction Manual

/01. Western Pacific AA F-3 Set Shell Replacement Instruction Manual 71-8191-250 8/01 Western Pacific AA F-3 Set Shell Replacement Instruction Manual Western Pacific AA F-3 Set Shell Replacement Table of Contents Replacing the Shell of the Powered F-3 Unit Removing the

More information

JMAA-1800HR15. Installation and Operation Instructions. 180w Performance Series Amplifier Kit For Harley RoadGlide/ Ultra

JMAA-1800HR15. Installation and Operation Instructions. 180w Performance Series Amplifier Kit For Harley RoadGlide/ Ultra 180w Performance Series Amplifier Kit For 2015-2018 Harley RoadGlide/ Ultra # JMAA-1800HR15 2017 J&M Corporation. All rights reserved. 9/17 Installation and Operation Instructions Product Description This

More information

K-Factor Scaler F5140 and Programming Kit F5141 Installation & Operating Instructions

K-Factor Scaler F5140 and Programming Kit F5141 Installation & Operating Instructions F5140 and Programming Kit F5141 8635 Washington Avenue Racine, WI 53406 USA Tel: 800-433-5263 or 262-639-6770 Fax: 800-245-3569 or 262-639-2267 E-Mail: flo-techsales@racinefed.com www.flo-tech.com TABLE

More information

OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM

OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM Version 3.0 (European version 1.3) This is a general manual describing a series of racks receiving Servo Amplifiers having output capability suitable

More information

Performance Series 360w Amplifier Kit For Harley RoadGlide with Lower/Rear Speakers JMAA-3600HR15-RC

Performance Series 360w Amplifier Kit For Harley RoadGlide with Lower/Rear Speakers JMAA-3600HR15-RC Performance Series 360w Amplifier Kit For 2015-2018 Harley RoadGlide with Lower/Rear s # JMAA-3600HR15-RC 2017 J&M Corporation. All rights reserved. 9/17 Installation and Operation Instructions Product

More information

Instruction Manual MTX-8485 MRX-8485 Four Channel Video Multiplexer with Bi-directional Data

Instruction Manual MTX-8485 MRX-8485 Four Channel Video Multiplexer with Bi-directional Data Instruction Manual MTX-8485 MRX-8485 Four Channel Video Multiplexer with Bi-directional Data Copyright 2003, American Fibertek, Inc. 0530JD Table of Contents 2 Functional Description... 4 Installation...

More information

POINTAX 6000L2 Point Recorder

POINTAX 6000L2 Point Recorder GOSSEN METRAWATT CAMILLE BAUER Special Features 6 measuring channels Last printed point visible from front Electrically isolated, earth-free measuring channels Process signals ranging from 0/4... 20 ma,

More information

For Precise Volume Adjustment with Programmable Muting in Any Room

For Precise Volume Adjustment with Programmable Muting in Any Room INSTALLATION & USER GUIDE For Precise Volume Adjustment with Programmable Muting in Any Room 12 STEP MUTING WALL MOUNT VOLUME CONTROL V-12M V-12M 12 STEP MUTING WALL MOUNT VOLUME CONTROL TABLE OF CONTENTS

More information

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5 SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5 Phone: (905) 564-0801 Fax: (905) 564-0806 www.telecor.com E:\T2-108\T2-M108-ABC\T2-M108-B.doc/AD

More information

80i-600A AC Current Probe

80i-600A AC Current Probe x Instruction Sheet 80i-600A AC Current Probe INTRODUCTION The Model 80i-600A is a clamp-on ac current probe designed to extend the current measuring capability of an ac current meter to 600 amperes. A

More information

M2 Antenna Systems, Inc. Model No: S3 Sequencer. Operating Instructions

M2 Antenna Systems, Inc. Model No: S3 Sequencer. Operating Instructions WARRANTY ADDENDUM TROUBLESHOOTING INSTALLATION OVERVIEW M2 Antenna Systems, Inc. Model No: S3 Sequencer Operating Instructions PLEASE READ BEFORE USE AND SAVE M2 Antenna Systems, Inc. 4402 N. Selland Ave.

More information

C Mono Camera Module with UART Interface. User Manual

C Mono Camera Module with UART Interface. User Manual C328-7221 Mono Camera Module with UART Interface User Manual Release Note: 1. 16 Mar, 2009 official released v1.0 C328-7221 Mono Camera Module 1 V1.0 General Description The C328-7221 is VGA camera module

More information

MLA High Performance Microstepping Driver. User s Guide E. Landon Drive Anaheim, CA

MLA High Performance Microstepping Driver. User s Guide E. Landon Drive Anaheim, CA MLA10641 High Performance Microstepping Driver User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471

More information

Copyright 2014 by Minarik Drives

Copyright 2014 by Minarik Drives Copyright 2014 by Minarik Drives All rights reserved. No part of this document may be reproduced or transmitted in any form without written permission from Minarik Drives. The information and technical

More information

ARBE-III Instruction Manual

ARBE-III Instruction Manual ARBE-III Instruction Manual Introduction ARBE-III is a solid state, fully regulated, universal power supply designed specifically for use of pre 1930 s battery operated radios. Three electronically isolated

More information

Installation and Assembly: Recessed Cable Management and Power Storage Accessory Box

Installation and Assembly: Recessed Cable Management and Power Storage Accessory Box Installation and Assembly: Recessed Cable Management and Power Storage Accessory Box Models: IBA3, IBA3-W 2300 White Oak Circle Aurora, Il 60502 (800) 865-2112 Fax: (800) 359-6500 www.peerlessmounts.com

More information

MIRAGE BD-38-G DUAL BAND POWER AMPLIFIER

MIRAGE BD-38-G DUAL BAND POWER AMPLIFIER MIRAGE BD-38-G DUAL BAND POWER AMPLIFIER MIRAGE BD-38-G Dual Band Amplifier INTRODUCTION: The Mirage BD-38-G is a 80/60 watt dual band power amplifier for use with today's dual band handie talkies operating

More information

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH INSTRUCTION MANUAL PLEASE READ THIS MANUAL BEFORE OPERATING THIS EQUIPMENT! 116 Willow Road Starkville, MS 39759 USA 662-323-8211 Version 3B Printed in U.S.A.

More information

INSTALLATION GUIDE. 8 Port IP Video Extender Over Coax With Built-In Gigabit PoE Switch

INSTALLATION GUIDE. 8 Port IP Video Extender Over Coax With Built-In Gigabit PoE Switch USA EUROPE ER8500C INSTALLATION GUIDE 8 Port IP Video Extender Over Coax With Built-In Gigabit PoE Switch Description The ER8500C is another component of NITEK s cutting edge EtherStretch line. Our Etherstretch

More information

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS 10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS The Analog / Digital PWM controller allows you to control the speed of a motor, brightness of a lamp or other device using an analog

More information

Amplifier Series BASIC. Installation & Operations Manual

Amplifier Series BASIC. Installation & Operations Manual Amplifier Series BASIC Installation & Operations Manual Bittner-Audio 200 Power Amplifier Series BASIC Bittner - Audio September 200 200 Bittner-Audio. All Rights Reserved. Bittner-Audio reserves specification

More information

Instruction Manual Model M Switch, DPDT, Manual Select

Instruction Manual Model M Switch, DPDT, Manual Select Instruction Manual Model 1582-70M Switch, DPDT, Manual Select November 2018 Rev 0 STATUS MODEL 1582 CROSS TECHNOLOGIES INC. MANUAL SELECT POWER Data, drawings, and other material contained herein are proprietary

More information

AIU3 Installation Manual

AIU3 Installation Manual AIU3 Installation Manual RESEARCH CONCEPTS INC. 9501 Dice Lane Lenexa, Kansas 66215 USA VOICE: (913) 422-0210 FAX: (913) 422-0211 www.researchconcepts.com support@researchconcepts.com Contents subject

More information

This product is for use in a dry, indoor environment only. This product is not to be installed near water, liquid, or flammable materials.

This product is for use in a dry, indoor environment only. This product is not to be installed near water, liquid, or flammable materials. The equipment described in this manual contains high voltage. Always disconnect power to the equipment before installing, disconnecting, or servicing the product. This product is for use in a dry, indoor

More information

INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF. KB Part No Signal Isolator for KBVF Controls. See Page 1 Pending

INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF. KB Part No Signal Isolator for KBVF Controls. See Page 1 Pending INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF KB Part No. 9474 Signal Isolator for KBVF Controls See Page 1 Pending See Safety Warning on Page 1 The information contained in this manual is intended

More information

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer 110 Toledo Street Farmingdale, NY 11735 USA http://www.netech.org 510-USER-Manual Rev3 10/29/2007 Dear User, We appreciate your purchase of the LKG

More information

User Instructions. Model PS-2001L. Power Supply. Model SPS Power Supply. Audiocom Intercom Systems Rev. A, 4/2001.

User Instructions. Model PS-2001L. Power Supply. Model SPS Power Supply. Audiocom Intercom Systems Rev. A, 4/2001. User Instructions PS-00L Model PS-00L Power Supply SPS-00 Volume Model SPS-00 Power Supply Audiocom Intercom Systems 950-7699-000 Rev. A, /00 FCC Statement This equipment uses, and can radiate radio frequency

More information

USER MANUAL. MODEL 457B Seven Port Active Twinax Star Hub. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 457B Seven Port Active Twinax Star Hub. SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 457B Seven Port Active Twinax Star Hub An ISO-9001 Certified Company Part #07M457B-C Doc. #069011UC Revised 4/22/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com

More information

COMMERCIAL TRANSMITTER INSTRUCTIONS

COMMERCIAL TRANSMITTER INSTRUCTIONS READ THIS MANUAL CAREFULLY BEFORE BEGINNING COMMERCIAL INSTRUCTIONS MODELS: 831, 8833 OCS: 1-DOOR 733, 8833C OCS: 3-DOOR 639: 9-DOOR 535: 27-DOOR PRODUCT FEATURES Allstar Commercial Transmitters are designed

More information

SUPPLY NETWORK ANALYZER CVM-96 SERIES

SUPPLY NETWORK ANALYZER CVM-96 SERIES SUPPLY NETWORK ANALYZER CVM-96 SERIES (Power Demand) INSTRUCTION MANUAL ( M 981 326 / 00B - GB) (c) CIRCUTOR S.A. ----- Supply network analyzer CVM-96 ------ User's manual --- Page No. 1 CVM-96 SUPPLY

More information

DA208 & DA416 DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

DA208 & DA416 DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL DA208 & DA416 DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL Copyright 2011, ATI Audio Inc. DESCRIPTION Your DA208 or DA416 provides two (DA208) or four (DA416) independent one-in by four-out

More information

Preliminary Data Sheet!

Preliminary Data Sheet! HELLROARING TECHNOLOGIES, INC. P.O. BOX 1521 POLSON, MT 59860 406 883-3801 HTTP://WWW.HELLROARING.COM SALES11@HELLROARING.COM SSD-100200-1200V-XP-XC Preliminary Data Sheet! The SSD-100200-1200V-XP-TTL

More information

8 Channel, DMX to 0 10 volt, Decoder board

8 Channel, DMX to 0 10 volt, Decoder board 8 Channel, DMX to 0 10 volt, Decoder board Allows DMX512 digital protocol to control analog devices that require a 0-10VDC control voltage. Upgrade 0-10 volt analog dimmers, use with motor controllers

More information

CAB LINK User Guide. Radial Engineering Ltd Kebet Way, Port Coquitlam BC V3C 5M5 Tel: Fax:

CAB LINK User Guide. Radial Engineering Ltd Kebet Way, Port Coquitlam BC V3C 5M5 Tel: Fax: CAB LINK User Guide TM 15 Kebet Way, Port Coquitlam BC V3C 5M5 Tel: 60-92-1001 Fax: 60-92-1010 Email: info@radialeng.com Cab-Link Speaker Cabinet Combiner FEATURES Features... 1 Making Connections...2-3

More information

15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS

15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS 15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS The SPD-315-D(S) PWM controller allows you to control the speed of a motor, brightness of a lamp or other load using a

More information

M2/M2A AC-DC Power Supply Operator s Manual

M2/M2A AC-DC Power Supply Operator s Manual M2/M2A AC-DC Operator s Manual Part Number: 71-0247RK Revision: A Released: 5/18/15 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warranties gas alarm equipment sold by us to be free from

More information

Vi6208, Vi6216, Vi6232 Vi6308, Vi6316, Vi6332

Vi6208, Vi6216, Vi6232 Vi6308, Vi6316, Vi6332 MODELs Vi6208, Vi6216, Vi6232 Vi6308, Vi6316, Vi6332 Automatic Video Compensation UTP Receiver Hubs User s Manual 7810 Trade Street, Suite 100 San Diego, CA 92121, U.S.A. Phone: (858) 484-5209 Fax: (858)

More information

Mini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version

Mini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version MR9 WARRANTY Steffes Corporation ( Steffes ) warrants that the Steffes Power Line Carrier Mini Receiver is free from defects in materials and workmanship under normal use and service. Steffes obligation

More information

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR 40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR The BIDIR-340-DR is a fully solid-state motor controller that allows you to control the speed and direction of a

More information

DANFYSIK A/S - DK-4040 JYLLINGE - DENMARK

DANFYSIK A/S - DK-4040 JYLLINGE - DENMARK 2 TABLE OF CONTENTS PAGE 1. INTRODUCTION AND SPECIFICATIONS. 1.1 Introduction... 4 1.1.1 Working principle....4 1.2 Warranty...5 2. RECEIVING AND UNPACKING. 2.1 Receiving the goods....6 2.2 Instructions

More information

Kotron Sentinel Model 804 RF Level Transmitter

Kotron Sentinel Model 804 RF Level Transmitter Kotron Sentinel Model 804 RF Level Transmitter D E S C R I P T I O N The Sentinel is a unique, powerful level transmitter. The leading-edge microprocessor-based circuitry has nonvolatile memory. The display

More information

S 275 Stereo Power Amplifier THE LEADER IN AUDIO ENGINEERING. Instructions for Use. Owner s Reference

S 275 Stereo Power Amplifier THE LEADER IN AUDIO ENGINEERING. Instructions for Use. Owner s Reference THE LEADER IN AUDIO ENGINEERING S 275 Stereo Power Amplifier Instructions for Use Owner s Reference Introduction Thank you for your purchase of the Krell S-275 Stereo Power Amplifier. This configurable

More information

MODEL FS-4 INSTRUCTION MANUAL R.L. DRAKE COMPANY, MIAMISBURG, OHIO, U.S.A.

MODEL FS-4 INSTRUCTION MANUAL R.L. DRAKE COMPANY, MIAMISBURG, OHIO, U.S.A. MODEL FS-4 F R E Q U E N C Y S Y N T H E S I Z E R INSTRUCTION MANUAL R.L. DRAKE COMPANY, MIAMISBURG, OHIO, U.S.A. LIMITED WARRANTY R. L. DRAKE COMPANY warrants to the original purchaser that this product

More information

Instruction Manual. KP-1 Series 10M, 6M, 2M, 1-1/4M, 70 CM. IN-SHACK GaAsFET PRE-AMPLIFIER. MIRAGE KP-1 Pre-Amplifier

Instruction Manual. KP-1 Series 10M, 6M, 2M, 1-1/4M, 70 CM. IN-SHACK GaAsFET PRE-AMPLIFIER. MIRAGE KP-1 Pre-Amplifier Instruction Manual IN-SHACK GaAsFET PRE-AMPLIFIER KP-1 Series 10M, 6M, 2M, 1-1/4M, 70 CM Version A Copyright 1996, MIRAGE Communications Before operating this unit, please read these instructions completely.

More information

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., and may not be reproduced or duplicated in any form

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions conduit? 9/8/10 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. Can branch circuits of different services be installed in the same Yes, see 300.3(C)(1) for conductors of different systems

More information

Performance Series 360w 4-CH Amplifier Kit For Harley Street Glide with Lower/Rear Speakers JMAA-3600HC14-SG

Performance Series 360w 4-CH Amplifier Kit For Harley Street Glide with Lower/Rear Speakers JMAA-3600HC14-SG Performance Series 360w 4-CH Amplifier Kit For 2014-2018 Harley Street Glide with Lower/Rear s # JMAA-3600HC14-SG 2017 J&M Corporation. All rights reserved. 9/17 Installation and Operation Instructions

More information

SEC. Technical Manual. SEC America, LLC. Model SFQ1K400 Frequency Converter

SEC. Technical Manual. SEC America, LLC. Model SFQ1K400 Frequency Converter SEC SEC America, LLC Model SFQ1K400 Frequency Converter Technical Manual May 11, 2012 Table of Contents Page 1 Purpose of Manual 1 1 Purpose of Equipment 1 1.1 Description and Theory of Operation 1 2 Electrical

More information

JAMP-700HR15-RCP. Installation and Operation Instructions. ROKKER XXRP 700w Amplifier Kit For Harley RoadGlide with Lower/Rear Speakers

JAMP-700HR15-RCP. Installation and Operation Instructions. ROKKER XXRP 700w Amplifier Kit For Harley RoadGlide with Lower/Rear Speakers ROKKER XXRP 700w Amplifier Kit For 2015-2018 Harley RoadGlide with Lower/Rear s # JAMP-700HR15-RCP 2018 J&M Corporation. All rights reserved. 4/18 Installation and Operation Instructions Product Overview

More information

Installation and Assembly: Recessed Cable Management and Power Storage Accessory Box

Installation and Assembly: Recessed Cable Management and Power Storage Accessory Box Installation and Assembly: Recessed Cable Management and Power Storage Accessory Box Models: IBA2AC, IBA2AC-W 2300 White Oak Circle Aurora, Il 60502 (800) 865-2112 Fax: (800) 359-6500 www.peerlessmounts.com

More information

Model 72D Twin Blade Rotary Wire Stripper

Model 72D Twin Blade Rotary Wire Stripper 110 Fairgrounds Drive P.O. Box 188 Manlius, NY 13104-0188 USA 315.682.9176 FAX: 315.682.9160 OPERATOR S MANUAL Model 72D Twin Blade Rotary Wire Stripper PRODUCTION WIRE PROCESSING EQUIPMENT Website: www.carpentermfg.com

More information

USER S MANUAL PROCESS CONTROL MODULE PCM3

USER S MANUAL PROCESS CONTROL MODULE PCM3 USER S MANUAL PROCESS CONTROL MODULE PCM3 Copyright 2002 by Minarik Corporation All rights reserved. No part of this manual may be reproduced or transmitted in any form without written permission from

More information

Installation Instructions Hustler Collinear Two Meter Fixed Station Antenna Master Gainer Model G6-144B

Installation Instructions Hustler Collinear Two Meter Fixed Station Antenna Master Gainer Model G6-144B Installation Instructions Hustler Collinear Two Meter Fixed Station Antenna Master Gainer Model Warning INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS. FOR YOUR SAFETY, FOLLOW THE INSTALLATION

More information

High Frequency Sinewave Guardian TM Filter

High Frequency Sinewave Guardian TM Filter High Frequency Sinewave Guardian TM Filter 380V 480V TECHNICAL REFERENCE MANUAL FORM: SHF-TRM-E REL. April 2015 REV. 001 2015 MTE Corporation Caution Prior to start up; confirm the drive operation mode

More information

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free 2001A 200KHz Function Generator Instruction Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com WARRANTY Global Specialties

More information

Copyright Teletronics International, Inc. Patent Pending

Copyright Teletronics International, Inc. Patent Pending Copyright 1999 by Teletronics International, Inc. Patent Pending All Rights Reserved. No part or parts of this document may be reproduced, translated, stored in any electronic retrieval system, or transmitted,

More information

Instruction Manual MX-485-S Bi-directional RS485 Data Transceiver

Instruction Manual MX-485-S Bi-directional RS485 Data Transceiver Instruction Manual MX-485-S Bi-directional RS485 Data Transceiver Copyright 2005, American Fibertek, Inc. 1020JD Table of Contents Functional Description...3 Installation...3 Power Source...3 Power Connection...3

More information