General Specifications

Size: px
Start display at page:

Download "General Specifications"

Transcription

1 General Specifications GS 1E2C1-1E AXFA11G Magnetic Flowmeter Remote Converter The AXFA11 magnetic flowmeter high grade remote converter is a sophisticated product with outstanding reliability and ease of operation, developed on the basis of decades of field-proven experience. The AXFA11 employs an LCD indicar, infra-red switches, and Easy Setup parameters ensure substantially improved ease of maintenance. The combination of a replaceable electrode type flowtube and diagnostics detect the adhesion level on the electrodes dramatically improves maintainability. The AXFA11 also employs the fluid noise free Dual Frequency Excitation Method and the newly added Enhanced Dual Frequency Excitation Method as an option for more difficult applications ensure greater stability and quicker response. Note: The Dual Frequency Excitation Method is Yokogawa s unique technology. FEATURES User-oriented Functionality Fluid Adhesion Level Diagnosis By constantly moniring the level of insulating substance on the electrodes, it is possible determine when maintenance is required. With the utilization of an optional replaceable electrode type flowtube, in cases of severe adhesion, the electrodes can be easily removed from the flowmeter and cleaned. Clear and Versatile Indications The LCD indicar employs a large, backlit full dotmatrix, that can facilitate various displays. One three lines are available. When there is an alarm condition, a full description of the countermeasure is indicated. Easy Setup Parameters The most frequently used parameters are arranged in a group at the p. The infra-red switches enable the users set parameters without opening the cover. Operation Immediately after Installation The AXFA11 is shipped with the main parameters completely set. Therefore, the AXFA11 can be operated immediately after installation and wiring. Compact and Light-weight Amplifier The AXFA11 is equipped with a compact and lightweight amplifier. Expansion of Product Lineup Improve Accuracy Specification The standard accuracy is.35% of reading. Also available is an optional high accuracy calibration rated at.2% of reading. Enhanced Performance and Specifications Enhanced Dual Frequency Excitation Method The Enhanced Dual Frequency Excitation Method can be optionally selected. For difficult applications such as for high concentration slurries or low conductivity fluid, extremely stable measurements can be realized. Improved Minimum Conductivity The newly designed AXF converter permits the measurement of fluids with conductivity as low as 1µS/cm. High-Speed Pulse Output The pulse rate now goes up 1, pps (pulse/ second) for use with high speed applications such as in short time batch processes. Versatile Input/ouput Function Now Available The functions of one current output, one pulse output, one alarm output, two status inputs, and two status outputs are available. CONTENTS Features P. 1 Standard Specifications P. 2 Standard Performance P. 4 Normal Operating Conditions P. 5 Accessories P. 5 Model and Suffix Code P. 6 Optional Specifications for AXFA11 Remote Converter P. 7 Terminal Configuration, Terminal Wiring P. 7 External Dimensions P. 8 Ordering Information P.1 Yokogawa Electric Corporation Nakacho, Musashino-shi, Tokyo 18, Japan Tel.: Fax.: GS 1E2C1-1E Copyright June 23 7th Edition Nov. 29

2 STANDARD SPECIFICATIONS Excitation Method: (Combined with AXF Remote Flowtube) Standard dual frequency excitation: Size mm (.1 16 in.) Enhanced dual frequency excitation: Size 25 2 mm (1. 8. in.) (Optional code HF1 or HF2) Pulsed DC excitation: Size 5 26 mm (2 14 in.) Input Signal: Two Status Inputs: Dry contact Load resistance: 2 or less (ON), 1 kω or more (OFF) Output Signals: One Current Output: 4 2 ma DC (load resistance: 1kΩ maximum, including cable resistance) One Pulse Output: Transisr contact output (open collecr) Contact capacity: 3 V DC (OFF), 2 ma (ON) Output rate:.1 1, pps (pulse/second) One Alarm Output: Transisr contact output (open collecr) Contact capacity: 3 V DC (OFF), 2 ma (ON) Two Status Outputs: Transisr contact output (open collecr) Contact capacity: 3 V DC (OFF), 2 ma (ON) Communication Signals: BRAIN or HART communication signal (Superimposed on the 4 2 ma DC signal) Distance from Power Line: 15 cm (6 in.) or more (Parallel wiring should be avoided.) BRAIN: Communication Distance: Up 1.5 km (.93 miles), when polyethylene insulated PVC-sheathed cables (CEV cables) are used. Communication distance varies depending on the type of cable and wiring used. Load Resistance: Ω (including cable resistance) Load Capacitance:.22 µf or less Load Inductance: 3.3 mh or less Input Impedance of Communicating Device: 1 kω or more (at 2.4 khz) HART: Load Resistance: 25 6 Ω (including cable resistance) Note: HART is a registered trademark of the HART Communication Foundation. 2 Data Security During Power Failure: Data (parameters, talizer value, etc.) srage by EEPROM. No back-up battery required. Indicar: Full dot-matrix LCD ( pixels) Lightning Protecr: The lightning protecr is built in the excitation current output, the current output, the signal common, and the pulse/alarm/status input and output terminals. When optional code A is selected, the lightning protecr is built in the power terminals. Protection: IP66, IP67, JIS C92 immersion-proof type Coating: Case and Cover: Corrosion-resistant coating Coating Color; Silver gray (Munsell 3.2PB 7.4/1.2 or its equivalent) Cover Mounting Screws: Polyurethane corrosion-resistant Coating Color: Mint green (Munsell 5.6BG 3.3/2.9 or its equivalent) Converter Material: Case and Cover: Aluminum alloy Mounting/Shapes: Mounting: 2-inch pipe, panel or surface mounting Electrical Connection: ANSI 1/2 NPT female ISO M2 1.5 female JIS G1/2 (PF1/2) female Terminal Connection: M4 size screw terminal Grounding: Grounding resistance 1 Ω or less When optional code A is selected, grounding resistance 1 Ω or less shall be applied. Combined Remote Flowtube: AXFA11 Converter can be combined with size mm (.1 14 in.) of AXF Remote Flowtube. However, the AXFA11 converter cannot combine with AXF Remote Flowtube of TIIS flame proof type (In this case, use the AXFA14 converter). If a combined converter is changed from AXFA11 AXFA14 or vice versa, a new meter facr must be adjusted by flow calibrations.

3 Functions How Set Parameters: The indicar s LCD and three infra-red switches enable users set parameters without opening the case cover. Parameters can also be set by means of the HHT(Handheld terminal). Displayed Languages: Users can choose a language from among English, Japanese, German, French, Italian, Spanish. Instantaneous Flow Rate/Totalized Value Display Functions: The full dot-matrix LCD enables user selections of displays from one line three lines for: Instantaneous flow rate Instantaneous flow rate (%) Instantaneous flow rate (bar graph) Current output value (ma) Totalized forward-direction flow rate Totalized reverse-direction flow rate Totalized differential flow rate Tag No. Results of electrode adhesion diagnostics Communication type Totalizer Display Function: The flow rate is counted one pulse at a time according the setting of talization pulse weights. For forward and reverse flow measurement functions, the talized values of the flow direction (forward or reverse) and the flow direction are displayed on the indicar gether with the units. The difference of talized values between the forward and reverse flow rate can be displayed. Totalization for the reverse flow rate is carried out only when Forward and reverse flow measurement functions is selected. Damping Time Constant: Time constant can be set from.1 second 2. seconds (63% response). Span Setting Function: Span flows can be set in units such as volume flow rate, mass flow rate, time, or flow rate value. The velocity unit can also be set. Volume Flow Rate Unit: kcf, cf, mcf, Mgal (US), kgal (US), gal (US), mgal (US), kbbl (US)*, bbl (US)*, mbbl (US)*, µbbl (US)*, Ml (megaliter), m 3, kl (kiloliter), l (liter), cm 3 Mass Flow Rate Unit (Density must be set.): klb (US), lb (US), t (n), kg, g Velocity Unit: ft, m (meter) Time Unit: s (sec), min, h (hour), d (day) * US Oil or US Beer can be selected. Pulse Output: Scaled pulse can be output by setting a pulse weight. Pulse Width:Duty 5% or fixed pulse width (.5,.1,.5, 1, 2, 33, 5, 1 ms) can be selected. Output Rate:.1 1, pps (pulse/second) 3 Multi-range Function: Range switching via status input Status input enables the switching of up four ranges. Aumatic range switching When the flow rate exceeds 1 % of the range, transition the next range (up four ranges) is carried out aumatically. Range switching can be confirmed by status outputs and indicar. Forward and Reverse Flow Measurement Functions: Flows in both forward and reverse directions can be measured. The reverse flow measurement can be confirmed by status output and indicar. Totalization Switch: The status output is carried out when a talized value becomes equal or greater than the set value. Preset Totalization: The parameter setting or status input enables a talized value be preset a setting value or zero. % Signal Lock: Status input forcibly fixes the instantaneous flow rate display, current output, pulse output, and flow rate talization %. Alarm Selection Function: Alarms are classified in System Alarms (hard failures), Process Alarms (such as Empty Pipe, Signal Overflow and Adhesion Alarm ), Setting Alarms, and Warnings. Whether alarms should be generated or not can be selected for each item. The current output generated for an alarm can be selected from among 2.4 ma or less, fixed 4 ma, 21.6 ma or more, or HOLD. Alarm Output: Alarms are generated only for the items selected via the Alarm Selection Function if relevant failures occur. Self Diagnostics Functions: If alarms are generated, details of the System Alarms, Process Alarms, Setting Alarms and Warnings are displayed gether with concrete descriptions of countermeasures. Flow Upper/Lower Limit Alarms: If a flow rate becomes greater or smaller than the set value, this alarm is generated. In addition, two upper limits (H, HH) and two lower limits (L, LL) can be set. If a flow rate becomes greater or smaller than any of the set values, the status is output. Electrode Adhesion Diagnostics Function: This function enables moniring of the adhesion level of insulating substances the electrodes. Depending on the status of adhesion, users are notified by a warning or an alarm via status outputs. If replaceable electrodes are used, they can be removed and cleaned when adhesion occurs.

4 STANDARD PERFORMANCE Accuracy (Combined with AXF Remote Flowtube) Note: The accuracy of a product before shipment is defined as talized value at the result of calibration test in our water actual flow test facility. Calibrated conditions in our water actual test facility are as follows: Fluid temperature; 2 ± 1 C Ambient temperature; 2 ± 5 C Length of straight runs;1 D or more on the upstream side; 5 D or more on the downstream side Reference conditions; Similar BS EN2914 (1993); ISO 914 (1991) Pulse Output: PFA/Ceramics Lining: Size mm (in.) 2.5 (.1) 15 (.5) 25 (1.) 2 (8.) 25 (1) 4 (16) Flow Velocity V m/s (ft/s) V.3 (1).3 V 1 (1) (33) V.15 (.5).15 V 1 (.5) (33) V.15 (.5).15 V 1 (.5) (33) Standard Accuracy (Calibration code B) 1. mm/s.35% of Rate.5 mm/s.35% of Rate.5 mm/s.35% of Rate Flow Velocity V m/s (ft/s) V.15 (.5).5 mm/s.15 V 1.18 (.5) (3.3).2mm/s 1 V 1 (3.3) (33) Enhanced dual frequency excitation (Option code HF2) : Standard accuracy 1 mm/ s Size 2.5 mm (.1 in.) 15 mm (.5 in.) Pulse Output Accuracy High Standard grade Accuracy High grade Accuracy (Calibration code C) Size 25 mm (1. in.) 4 mm (16 in.) Pulse Output Accuracy Standard Accuracy High grade Accuracy F1.EPS F2.EPS T1.EPS Polyurethane Rubber/Natural Soft Rubber/EPDM Rubber Lining Size mm (in.) 25 (1.) 4 (16) 5 (2) 1 (4) 11 (44) 2 (8) 22 (88) 26 (14) Flow Velocity V m/s (ft/s) Standard Accuracy (Calibration code B) V.3 (1.) 1. mm/s.3 V 1 (1.) (33).35 V.3 (1.) 1.75 mm/s.3 V 1 (1.) (3.3) 1 V 1 (3.3) (33).25 1 mm/s.35 V.3 (1.) 2.2 mm/s.3 V 1 (1.) (3.3).4 1 mm/s 1 V 1 (3.3) (33).5 V 1 (3.3) 1 V 1 (3.3) (33) 8.5 mm/s.85 T2.EPS Enhanced dual frequency excitation (Option code HF2) : Standard accuracy 1 mm/ s Size 25 mm (1. in.) 4 mm (16 in.) Pulse Output Accuracy High Standard grade Accuracy F1.EPS Size 5 mm (2 in.) 1 mm (4 in.) Pulse.6 Output Accuracy High Standard grade Accuracy F16-1.EPS Size 11 mm (44 in.) 2 mm (8 in.) Pulse.6 Output.5 Accuracy.4.2 High Standard grade Accuracy F16-2.EPS 4

5 Size 22 mm (88 in.) 26 mm (14 in.) Pulse 1.2 Output Accuracy High Standard grade Accuracy F16-3.EPS Current Output: Pulse output accuracy plus.5% of Span Repeatability:.1 (V 1 m/s (3.3 ft/s)).5.5 mm/s (V < 1 m/s (3.3 ft/s)) Maximum Power Consumption: Combined with AXF Remote Flowtube: 2 W Insulation Resistance(*1) : Between power supply terminals and ground terminal: 1MΩ at 5V DC Between power supply terminals and input/output/ excitation current terminals : 1MΩ at 5V DC Between ground terminal and input/output/excitation current terminals: 2MΩ at 1V DC Between input/output/excitation current terminal: 2MΩ at 1V DC Withstand Voltage(*1) : Between power supply terminals and ground terminal: 139V AC for 2 seconds Between power supply terminals and input/output terminals: 139V AC for 2 seconds Between excitation current terminal and ground terminal: 16V AC for 2 seconds Between excitation current terminal and input /output terminals: 2V AC for 2 seconds CAUTION *1: When performing the Insulation Resistance Test or the Withstand Voltage Test, please obey the following caution. Following the relevant test, wait for more than 1 seconds after the power supply has been turned off before removing the cover. Remove all wires from terminals before testing. When the power terminal has a lighting protecr (optional code A), remove the short bar at the ground terminal. After testing, be sure discharge by using a resistance and return all wires and the short bar its correct position. Screws must be tightened a rque of 1.18 N-m or more. After closing the cover, the power supply can be resred. Safety Requirement Standards: EN611-1 Altitude at installation site: Max. 2 m above sea level Installation category based on IEC11: Overvoltage category II ( II applies electrical equipment which is supplied from a fixed installation-like distribution board.) Pollution degree based on IEC11 Pollution degree 2 ( Pollution degree describes the degree which a solid, liquid, or gas which deteriorates dielectric strength or surface resistivity is adhering. 2 applies a normal indoor atmosphere.) EMC Conformity Standards:, EN Class A, Table 2 (For use in industrial locations) EN EN Class A EN NORMAL OPERATING CONDITIONS Ambient Temperature: 4 C +6 C ( 4 F +14 F) Indicar s operating range: 2 C +6 C ( 4 F +14 F) Ambient Humidity: 1% Lengthy continuous operation at 95% or more is not recommended. Power Supply: Power supply code 1: AC specifications Rated power supply: 1 24 V AC, 5/6 Hz (Operating voltage range: V AC) DC specifications Rated power supply: 1 12 V DC (Operating voltage range: 9 13 V DC) Power supply code 2: AC specifications Rated power supply: 24 V AC, 5/6 Hz (Operating voltage range: V AC) DC specifications Rated power supply: 24 V DC (Operating voltage range: V DC) Allowable cable length m(ft) 42 (138) 28 ( 92) 2 ( 66) 1 ( 33) Supplied Power and Cable Length for Power Supply Code Usable range E (V) Cable cross section area: 1.25 mm 2 Cable cross section area: 2 mm 2 Vibration Conditions: Level of vibration in conformity with IEC (SAMA ) 4.9 m/s 2 or less (frequency of 5 Hz or less) Note: Avoid locations with much vibration (with a vibration frequency of 5 Hz or more), which may cause damage the equipment. F.EPS 5

6 ACCESSORIES Fuse (Time lag fuse): 1 pc. Power supply code 1; T2.5 A, 25 V Power supply code 2; T3.15A, 25 V Mounting bracket: 1 set MODEL AND SUFFIX CODE AXFA11 Magnetic Flowmeter Remote Converter: Model Suffix Code Description AXFA11 Magnetic Flowmeter Remote Converter General-Purpose Use Use G For AXF Remote Flowtube of size mm (.1 in. 14 in.) Output Signal and Communication Power Supply Electrical Connections Indicar Option -D -E ma DC, BRAIN Communication 4 2 ma DC, HART Communication 1 V 24 V AC or 1 12 V DC 24 V AC/DC (*1) JIS G1/2 female ANSI 1/2 NPT female ISO M2 1.5 female 1 With Indicar / Optional code (See the Table of Optional Specifications) *1: In case of power supply code 2 (24 V AC/DC), optional code A (lighting protecr) is mandary. T3.EPS Recommended Excitation, Power and Output Cable: Use Polyvinyl chloride insulated and sheathed control cable (JIS C341) or Polyvinyl chloride insulated and sheathed portable power cables (JIS C3312) or equivalents. Outer Diameter: mm ( in.) mm (.3.47 in.) for optional code EG, EU and EW 6 12 mm ( in.) for optional code EP Nominal Cross Section(single wire): mm 2 Nominal Cross Section(standard wire): mm 2 6 Signal Cable: Model Suffix Code Description AXFC Termination Cable Length Option L /C Magnetic Flowmeter Dedicated Signal cable for the ADMAG AXF series No Termination. A set of termination parts for M4 screws is attached. Terminated for the AXFA11/14 Converter. Designate the cable length, unit: m Following L, specify the cable in three digits as multiple of 1 meter (e.g., 1, 2, or 5) for a length up 5 m, or as a multiple of 5 meters (i.e., 5, 1, 15, or the like). The maximum cable length: 2 m for combined use with AXFA11 1 m for combined use with AXFA14 With termination parts sets. Following C, specify the q ty of sets of termination parts in one digits. T4.EPS Note: The cable is constructed with double shielding over the two conducrs, and uses heat-resistant vinyl as the outer covering material. Finished diameter: 1.5 mm (.413 in.) Maximum temperature: +8 C (+176 F) Unnecessary order the above cable for submersible type flowtube or for the optional code DHC flowtube because the flowtube is wired with 3 m (98 ft) cable. For excitation cable, prepare a two-core cable at the cusmer side.

7 7 OPTIONAL SPECIFICATIONS FOR AXFA11 REMOTE CONVERTER Item Specification Code Lightning Protecr DC Noise Cut Circuit Burn Out Down NAMUR NE43 Compliance Active Pulse Output G3/4 Female Waterproof Glands Waterproof Glands Waterproof Glands with Union Joints Plastic Glands Air Purge Fitting Stainless Steel Mounting Bracket AM11 Replacement Bracket Stainless Steel Tag Plate Painting Color Change Epoxy Resin Coating High Anti-corrosion Coating Calibration Certificate A lightning protecr is built in the power terminals. In case of power supply code 2 (24 V AC/DC), this optional code is mandary. The DC Noise Cut Circuit is built in. Available for 15 mm (.5 in.) and larger sizes, and for fluids with the conductivity of 5 µs/cm or higher. Nullifies the empty check and electrode adhesion diagnostics function. The output level is set ma during a CPU failure and is set 2.4 ma (-1%) or less during an alarm. Standard products are delivered with a setting 25 ma during a CPU failure and 21.6 ma (11%) or more during an alarm. Output signal limits: ma Failure alarm down-scale: The output level is set ma during a CPU failure and is set 2.4 ma ( 1%) or less during an alarm. Failure alarm up-scale. The output level is set 25 ma during a CPU failure and is set 21.6 ma (11%) or more during an alarm. Active pulses are output in order drive an external electromagnetic or electronic counter directly using the converter s internal power supply. (Nullfies the standard transisr contact pulse output.) Output voltage: 24 V DC ±2% Pulse specifications: The drive current of 3 15 ma Pulse rate:.1 2 pps (pulse/second); Pulse width: 2, 33, 5, or 1 ms Waterproof glands for G3/4 conduits or flexible tubes are attached the electrical connections. Available only for JIS G1/2 female electric connections. Waterproof glands are attached the electrical connections. Available only for JIS G1/2 female electric connections. Waterproof glands with union joints are attached the electrical connections. Available only for JIS G1/2 electric connections. Plastic glands are attached the electrical connections. Available only for JIS G1/2 female electric connections. Provided with an air purge fitting (1.5 L/min air consumption) with purge air pressure at.14 MPa or less. 1/4 NPT female (when electrical conn. code is 2 or 4) or Rc1/4 (PT 1/4) female (when electrical conn. code is ). Provided with a JIS SUS34 (AISI 34 SS/EN equivalent) stainless steel mounting bracket in lieu of the standard carbon steel bracket. Provided with a special mounting bracket for replacing an AM11 converter with an AXFA11. Screwed JIS SUS34 (AISI 34 SS/EN equivalent) stainless steel tag plate. Choose this option when an SS tag plate is required in addition the standard nameplate with the tag number inscribed on it. Dimension (Height Width): Appr (4.92) 4 (15.7) mm (inch) Coated in black (Munsell N1.5 or its equivalent.) Coated in jade green (Munsell 7.5BG4/1.5 or its equivalent.) Coated in metallic silver. Epoxy resin coating which has alkali-resistance instead of standard polyurethane resin coating. The color is same as standard type. Three-layer coating (polyurethane coating on two-layer epoxy resin coating) in the same range as that for the standard coating. The color is same as standard type. Salt/alkali/acid/weather- Level 2: The Declaration and the Calibration Equipment List are issued. Level 3: The Declaration and the Primary Standard List are issued. Level 4: The Declaration and the Yokogawa Measuring Instruments Control System are issued. A ELC C1 C2 C3 EM EW EG EU EP APC SB RK SCT P1 P2 P7 X1 X2 L2 L3 L4 T5.EPS Terminal Configuration I+ I CURRENT OUT SO1+ SO2+ COM STATUS OUT N/ L/+ POWER SUPPLY SHORT BAR EX1 EX2 EXCIT ATION AL+ AL C SA A B SB ALARM OUT SIGNAL P+ P SI1+ SI2+ COM PULSE OUT STATUS IN T6.EPS Terminal Wiring Terminal Symbols SIGNAL ALARM OUT STATUS OUT CURRENT OUT C SA A B SB AL+ AL- SO1+ SO2+ COM I+ I- Description Flow signal input Alarm output Status output (Two output) Current output 4 2mA DC Terminal Symbols STATUS IN PULSE OUT EXCITATION POWER SUPPLY Sl1+ Sl2+ COM P+ P- EX1 EX2 L /+ N/- Description Status input (Two input) Pulse output Excitation current output Power supply Functional grounding Protective grounding (Outside of the terminal) T7.EPS

8 8 EXTERNAL DIMENSIONS Remote Converter AXFA11G Pipe mounting 18(7.9) 4-ø6 Hole (Surface mounting hole) 12(4.72) Unit: mm (approx. inch) 65 (2.56) 21(8.27) 194(7.64) (1.22) (1.22) (1.22) (1.22) (67) (2.64) Panel mounting 1 1(.4.39) (Panel thickness) 1(3.94) Mounting Screw (M6 1(3.94)) 172(6.77) Panel cuut 23(7.99) 182(7.17) 15 (4.13) R3 MAX Surface mounting *1 Mounting Screw(M6) 18(.71) 65 (2.56) 24 (.94) (67) (2.64) 29 (1.14) 49 (1.93) Weight 3.3 kg (7.3 lb) *1: These screws must be provided by the user. 194(7.64) 62 (2.44) T8.EPS

9 9 Remote Converter AXFA11G /RK (AM11 Replacement Bracket) Pipe mounting 18(7.9) 4-ø6(.24) (Surface mounting hole) 133.5(5.26) (8.5) (3.17) 24 (.94) 29 (1.14) 65(2.56) 21(8.27) 194(7.64) (1.22) (1.22) (1.22) (1.22) 49 (1.93) (8.5) (3.17) Bracket for replacement (For pipe mounting) Surface mounting (19) (7.48) Mouting Screw *1 18(.71) (126.5) (4.98) *1: These screws must be * provided by the user. (62) (2.44) Bracket for replacement (For surface mounting) FFAXFA11E.EPS Unless otherwise specified, difference in the dimensions are refer the following table. Category of basic dimension Category of basic dimension Tolerance Above Equal or below Above Equal or below 3 (.12) 6 (.24) 1 (.39) 18 (.71) 3 (1.18) 5 (1.97) 8 (3.15) 12 (4.72) 18 (7.9) 25 (9.84) 315 (12.4) 4 (15.75) 3 (.12) 6 (.24) 1 (.39) 18 (.71) 3 (1.18) 5 (1.97) 8 (3.15) 12 (4.72) 18 (7.9) 25 (9.84) 315 (12.4) 4 (15.75) 5 (19.69) General lerance in the dimensional outline drawing..7 (.3).9 (.4) 1.1 (.4) 1.35 (.5) 1.65 (.6) 1.95 (.8) 2.3 (.9) 2.7 (.11) 3.15 (.12) 3.6 (.14) 4.5 (.16) 4.45 (.18) 4.85 (.19) 5 (19.69) 63 (24.8) 8 (31.5) 1 (39.37) 125 (49.21) 16 (62.99) 2 (78.74) 25 (98.43) Remarks: The numeric is based on criteria of lerance class IT18 in JIS B (24.8) 8 (31.5) 1 (39.37) 125 (49.21) 16 (62.99) 2 (78.74) 25 (98.43) 315 (124.2) Unit : mm (approx.inch) Tolerance 5.5 ( 2.17) 6.25 (.25) 7. (.28) 8.25 (.32) 9.75 (.38) 11.5 (.45) 14. (.55) 16.5 (.65)

10 1 Dedicated Signal Cable AXFC-4-L A 15 5 (5.91) 8(.31)Max (5.91) G 9(3.54) E B B 55(2.17) 9(3.54) F A Unit: mm (approx. inch) C SA SB C (WHITE) (BLACK) (RED) D (WHITE) (BLACK) (RED) 8(.31)Max. CONVERTER 2(.79) L(SPECIFIED LENGTH) AXFC ø1.5(.41) FLOW TUBE Model AXFC-4 D E F G 7(2.76) 25(.98) 5(1.97) 6(2.36) AXFC--L F4.EPS CAP ø1.5(.41) AXFC L(SPECIFIED LENGTH)+34(13.39)(LENGTH for END TREATMENT) F5.EPS ORDERING INFORMATION Note 1: When ordering in combination a remote flowtube and a remote converter, specify the flow span, unit, pulse weight, and talizer display pulse weight can be specified. These parameters will then be set in the combined converter before shipment. When ordering of a converter alone, these parameters cannot specify. Please refer GS1E2D1-1E ORDERING INFORMATION. Note 2: Some options, if ordered, require the relevant specifications be input when ordering. 1. Model, specification and option codes. 2. Tag number Each tag number can be specified in up 16 characters in a combination of letters (capital or small letters), numbers, - and.. For HART procol, up 8 characters can be specified. If specified, the tag number is inscribed on the product s name plate and tag plate (if optional code SCT is selected). The tag number is also set in the memory of converter. If the user wishes change only the tag number be set in a converter s memory, specify the software tag. If a tag number is not specified, the tag number is set as a blank. RELATED INSTRUMENTS Calibrar for Magnetic Flowmeter (AM12): GS 1E6K2-E BT2 Brain Terminal: GS 1CA11-E AXF Magnetic Flowmeter Integral Flowmeter/ Remote Flowtube: GS 1E2D1-1E AXFA14G/C Magnetic Flowmeter Remote Converter: GS 1E2C2-1E FieldMate: GS 1R1A1-1E REFERENCE Company names and product names used in this material are registered trademarks or trademarks of their respective owners. Subject change without notice.

General Specifications

General Specifications General Specifications AXFA11 Magnetic Converter for Remote Flowtube The AXFA11 magnetic converter has been developed based on Yokogawa s decades long experience in magnetic flowmeters. The AXFA11 continues

More information

General Specifications

General Specifications General Specifications GS 01E20C01-01E AXFA11 Magnetic Flowmeter Converter for Remote Flowtube The AXFA11 magnetic flowmeter high grade converter is a sophisticated product with outstanding reliability

More information

General Specifications

General Specifications eneral Specifications S 01E20C02-01E AXA14/C Magnetic lowmeter Remote Converter The AXA14 magnetic flowmeter remote converter is a sophisticated product with outstanding reliability and ease of operation,

More information

General Specifications

General Specifications eneral Specifications S 01E20C02-01E AXA14/C Magnetic lowmeter Remote Converter The AXA14 magnetic flowmeter remote converter is a sophisticated product with outstanding reliability and ease of operation,

More information

General Specifications

General Specifications General Specifications GS 1E22-1E XF14 Magnetic Flowmeter onverter for Remote Flowtube The XF14 magnetic flowmeter converter is a sophisticated product with outstanding reliability and ease of operation,

More information

General Specifications

General Specifications General Specifications EJA530E S-Series Cherry Burrell I Line Sanitary Pressure Transmitter GS 530SCBS-01E The EJA530E S-Series sanitary pressure transmitters combine Yokogawa s EJA-E series in-line pressure

More information

EGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification EGCW Converter for Electromagnetic Flowmeter GENERAL MAGMAX EGCW is the high-performance separate type converter for electromagnetic flowmeters with the compact housing. Improved self-diagnostic functions

More information

General Specifications

General Specifications General Specifications YTA70 Temperature Transmitter The YTA70 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

WDM-135A (2-wire type) WDM-136A (4-wire type) CONDUCTIVITY TRANSMITTER. Functions Features. Structure diagram. 10/ cm (note 3) 2-wire system

WDM-135A (2-wire type) WDM-136A (4-wire type) CONDUCTIVITY TRANSMITTER. Functions Features. Structure diagram. 10/ cm (note 3) 2-wire system CONDUCTIVITY TRANSMITTR WDM-A (-wire type) WDM-6A (-wire type) It is a type of small firm aluminum -electrode site-installation CONDUCTIVITY TRANSMITTR (signal transmitter) and easy operate. The device

More information

General Specifications

General Specifications General Specifications YTA110 Temperature Transmitter [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs and converts it to

More information

Electro-Magnetic Flowmeters COPA-XE

Electro-Magnetic Flowmeters COPA-XE Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates

More information

User's Manual Model SE14 Magnetic Flow Converter

User's Manual Model SE14 Magnetic Flow Converter User's Manual Model SE14 Magnetic Flow Converter Manual Change No. 09-001-6E Please use attached sheets for the pages listed below in (7th). Page Page 10-2 EMC Conformity Standards Contents Changed the

More information

User s Manual. AXFA11G Magnetic Flowmeter Remote Converter [Hardware Edition/Software Edition] IM 01E20C01-01E 7th Edition

User s Manual. AXFA11G Magnetic Flowmeter Remote Converter [Hardware Edition/Software Edition] IM 01E20C01-01E 7th Edition User s Manual AXFA11G Magnetic Flowmeter emote Converter [Hardware Edition/Software Edition] Yokogawa Electric Corporation 7th Edition CONTENTS Contents 1. INTODUCTION... 1-1 1.1 Using the Magnetic Flowmeter

More information

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit High performance microflow Coriolis Flowmeter GENERAL SPECIFICATION GS.No. GENERAL Based on the Coriolis technologies accumulated over many years, the OVAL has broadened its current general purpose coriolis

More information

General Specifications

General Specifications General Specifications YTA0, YTA0 Temperature Transmitter [Style: S] The YTA0 and YTA0 are the highly accurate temperature transmitters that accept Thermocouple, RTD, ohms or DC milivolts inputs and converts

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

General Specifications

General Specifications General Specifications GS 01C25F01-01E EJX510A and EJX530A Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJX510A and EJX530A feature single crystal

More information

IFC 010 Signal Converter

IFC 010 Signal Converter KROHNE 04/2003 7.02347.22.00 GR Signal Converter for electromagnetic flowmeters Easy to install Low-cost signal converter, measuring error < 0.5% of the measured value Easy user-friendly operation Self-monitoring

More information

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0 Touch Switch Unique 18 mm Capacitive Touch Switch with Choice of Three Actuators is Activated with Only a Very Slight Physical Contact Lightweight objects, such as thin wire or foil can be accurately detected.

More information

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

UFM 800 W, C Ultrasonic flowmeter for water and wastewater KROHNE 08/2000 7.02343.21.00 GR/PRINTO, C Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...withbuilt-on or built-in sensors for open channels Variable area flowmeters

More information

Dissolved Oxygen Transmitter

Dissolved Oxygen Transmitter Dissolved Oxygen Transmitter OBM-67H The OBM-67H is a -wire type (4VDC power supply) dissolved oxygen transmitter housed in a robust, die-cast aluminum enclosure suitable for installation out in the field.

More information

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector No. SS2-MGN200-0200 MagneW3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIEW The MagneW3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Introduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter

Introduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter Field Intelligent Device Series Electromagnetic Flowmeter Converter LF620,LF622 Introduction Combined with a multi-functional converter LF620 (combined type) or LF622 (separate type) equipped with its

More information

ThermoPLUS Smart Temperature Transmitter

ThermoPLUS Smart Temperature Transmitter No. SS2-TT110-0100 ThermoPLUS Smart Temperature Transmitter Model TT61/71 (Integral Sensor type) OVERVIEW The models TT61/71 Smart Transmitter are temperature transmitters for the model TT90 integral temperature

More information

General Specifications

General Specifications General Specifications YTA110 Temperature Transmitter [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs and converts it to

More information

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications

More information

SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER SYSTEM CONFIGURATION

SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER SYSTEM CONFIGURATION ISO-400 ISO-900 SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER Model: ODM-36A FEATURES Microprocessor based 4-wire transmitter suitable for field installation. The unit features isolated inputs

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Magne3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIE The Magne3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter mainly used for flow

More information

Magnetic Flowmeter Systems

Magnetic Flowmeter Systems Series 8700 Magnetic Flowmeter Systems THE 8700 SERIES... Model 8712 C/U - Easiest to use local operator interface and works with any manufacturer s flowtubes Model 8712H/8707 High-Signal System - Pulsed

More information

EN-2018 MAGNETIC FLOW METERS

EN-2018 MAGNETIC FLOW METERS EN-2018 MAGNETIC FLOW METERS www.meatest.com 1 MEASURING PRINCIPLE Having no moving or mechanical parts in the flow profile electromagnetic flow meters cause no pressure drop, are virtually maintenance

More information

General Specifications

General Specifications General Specifications US300FM Ultrasonic Flowmeter GS 01G05B03-01E GENERAL The model US300FM is an ultrasonic flowmeter for measuring liquid flow in a fully filled pipe. With the advanced signal processing

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

General Specifications

General Specifications General Specifications FN510 Field Wireless Multi-Function Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Multi-Function Module. Combined with Field Wireless

More information

General Specifications

General Specifications General Specifications Model YTA110 Temperature Transmitter GS 01C0B01-00E [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

Applications Features

Applications Features GE Measurement & Control TransPort PT878 Panametrics Portable Liquid Ultrasonic Flowmeter Applications The TransPort PT878 portable liquid flowmeter is a complete portable ultrasonic flow metering system

More information

OPTIFLUX 1000 Technical Datasheet

OPTIFLUX 1000 Technical Datasheet OPTIFLUX 1000 Technical Datasheet Electromagnetic flow sensor in sandwich design Lightweight and compact Excellent price performance ratio Quick and easy to install The documentation is only complete when

More information

TIDALFLUX 2300 F Technical Datasheet

TIDALFLUX 2300 F Technical Datasheet Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to

More information

Manostar Electronic Low Differential Pressure Measurement System

Manostar Electronic Low Differential Pressure Measurement System Manostar Electronic Low Differential Pressure Measurement System Manosys Presure Transmitter Intrinsically safe apparatus type Explosion-proof performance iag Intrinsically-safe apparatus is called by

More information

General Specifications

General Specifications General Specifications US300FM Ultrasonic Flowmeter GS 01G05B03-01E GENERAL The model US300FM is an ultrasonic flowmeter for measuring liquid flow in a fully filled pipe. With the advanced signal processing

More information

General Specifications

General Specifications General Specifications GS 01E24A0101EN ADMAG TI Series AXW Magnetic Flowmeter [: 25 to 400 mm (1 to 16 in.)] GENERAL DESCRIPTION The ADMAG TI (Total Insight) series AXW magnetic fl owmeter is a highquality

More information

Specifications ELECTROMAGNETIC FLOWMETER. LF664/LF620 LF664/LF to 78 (500 to 1950mm) Overall Specifications TIC-LF664K

Specifications ELECTROMAGNETIC FLOWMETER. LF664/LF620 LF664/LF to 78 (500 to 1950mm) Overall Specifications TIC-LF664K Field Intelligent Device Series-Mount Anywhere series-flanged ELECTROMAGNETIC FLOWMETER LF664/LF620 LF664/LF622 20 to 78 (500 to 1950mm) Introduction The electromagnetic flowmeter uses Faraday s Law of

More information

General Specifications

General Specifications General Specifications Signal Conditioner Cards OUTLINE Signal Conditioner Cards, which interface to the process, are installed in Signal Conditioner Nests. [Release 6] The signal conditioner cards can

More information

Submersible pressure sensor For oils and fuels Model LF-1

Submersible pressure sensor For oils and fuels Model LF-1 Level measurement Submersible pressure sensor For oils and fuels Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems for oils and fuels Overfilling and dry-run

More information

Electromagnetic flowmeters and switches DWM 1000/2000

Electromagnetic flowmeters and switches DWM 1000/2000 KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass

More information

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process

More information

PAD - Heavy Duty Differential Pressure Trasmitter

PAD - Heavy Duty Differential Pressure Trasmitter Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:

More information

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter.   TEMPERATURE. Technology Solutions Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof

More information

Submersible pressure sensor For water and wastewater Model LW-1

Submersible pressure sensor For water and wastewater Model LW-1 Replacement product: Model LF-1 Level measurement Submersible pressure sensor For water and wastewater Model LW-1 WIKA data sheet LM 40.03 Applications Level measurement in rivers and lakes Deep well and

More information

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display KMS101W Electromagnetic Wafer Flowmeters with S100 display ideal as resettable/batching meter (sizes: 15mm to 150mm) 0BFEATURES For ADMIXTURE Batching, Shotcrete, Mild-Recycled Water & Selected Chemical

More information

Technical Specification FLUXUS ADM 8127B

Technical Specification FLUXUS ADM 8127B FLUXUS ADM 8127B Liquid Ultrasonic Flowmeter for Permanent Installation in Hazardous Areas in the Mining Environment FLUXUS ADM 8127B is especially designed for the stationary use in explosive atmosphere

More information

MODEL: 47LV. Digital Panel Meters 47 Series

MODEL: 47LV. Digital Panel Meters 47 Series Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display

More information

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview Siemens AG 2010 Flow Measurement Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the TRANSMAG 2 for pulsed alternating field. These are available as

More information

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ). ISO-14001 ISO-9001 SPECIFICATION SHEET CP SERIES 2-WIRE TYPE DO TRANSMITTER Models: DCP-20T FEATURES Rigid aluminium enclosure with free angle mounting. Simple operation offers free range setting, auto-calibration,

More information

General Specifications

General Specifications General Specifications YTA60 Temperature Transmitter The YTA60 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

General Specifications

General Specifications General Specifications GS 11M12D01-01E Model AV550G Zirconia Oxygen Analyzer Averaging Converter Overview Zirconia oxygen analyzers are used in combustion facilities to measure the flue gas oxygen concentration.

More information

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4½ digit, LED display type) Functions & Features 4 ½ digit digital panel meter 1/8 DIN size Accepts a pulse train input to measure rotation

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Flowmeter SITRANS FUE80 with CT approval Overview The 2-path flowmeter SITRANS FUE80 comes as battery or mains-powered and is designed to measure water flow in district heating plants, local networks,

More information

WATERFLUX 3070 Technical Datasheet

WATERFLUX 3070 Technical Datasheet WATERFLUX 3070 Technical Datasheet Engineered and manufactured for the water and wastewater industry Highly accurate measurement with extremely short in- and outlet lengths Battery operated, stand alone

More information

MS 5000 CIAO SENSOR EXTREMELY EASY TO INSTALL THANKS TO PATENTED WRAPPER FIXING SYSTEM

MS 5000 CIAO SENSOR EXTREMELY EASY TO INSTALL THANKS TO PATENTED WRAPPER FIXING SYSTEM CIAO SENSOR MS 5000 EXTREMELY EASY TO INSTALL THANKS TO PATENTED WRAPPER FIXING SYSTEM Warranty conditions are available on this website: www.isomag.eu only in English version INDEX TECHNICAL DATA... 3

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track) The transmitter FUS080 is

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

Instruction MI December Magnetic Flow System

Instruction MI December Magnetic Flow System Instruction MI 021-138 December 2015 Magnetic Flow System 2800 Series Flowtubes with an 896 or an E96 Transmitter Fault Location Guide Contents Contents...3 Figures...5 Tables...6 Introduction...7 Reference

More information

OPTITEMP TT 20 Technical Datasheet

OPTITEMP TT 20 Technical Datasheet OPTITEMP TT 20 Technical Datasheet Analog PC-programmable two-wire transmitters for Pt100 Efficient PC-configuration without recalibration Very stable output Very fast response time The documentation is

More information

Miniature resistance thermometer Model TR33, thread-mounted

Miniature resistance thermometer Model TR33, thread-mounted Electrical temperature measurement Miniature resistance thermometer Model TR33, thread-mounted WIKA data sheet TE 60.33 Applications Machine building, plant and vessel construction Propulsion technology,

More information

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the

More information

Ambient Conditions. Operating Conditions. Pressure

Ambient Conditions. Operating Conditions. Pressure Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version

More information

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 Applications Machine building, plant and vessel construction Propulsion

More information

Mass and Volume Flow Transmitter

Mass and Volume Flow Transmitter IFT9701 Product Data Sheet PS-00218-EU December1999 Mass and Volume Flow Transmitter IFT9701 transmitter The IFT9701 microprocessor-based transmitter works with Micro Motion sensors to provide affordable,

More information

General Specifications

General Specifications General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter

More information

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm) KMS502F Electromagnetic Flanged Flowmeters (sizes: 25mm to 200mm) FEATURES: For all your water applications including batching. Flanged connection suites ANSI 150lb flanges. Unsurpassed accuracy to ±0.5%

More information

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction

More information

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite KFS Flap Flow Meter KFS suitable for H, acids, alkalis and gases spring-loaded horizontal or vertical flow direction low pressure loss mainly viscosity independent optional threshold value contacts optional

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009 VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet 34-VF-03-14 September 2009 Specification Clamp-on technology HONEYWELL S VERSAFLOW stands for continuity and long term reliability. Flow measurement

More information

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5) Electronic pressure measurement OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5) WIKA data sheet PE 81.65 Applications Hydraulics and pneumatics Pumps and compressors

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series MODEL: WDYS Space-saving Dual Output Signal Conditioners Mini-MW Series CURRENT LOOP SUPPLY Functions & Features Powers a 0 ma DC current loop Short circuit protection Applicable to smart transmitters

More information

User s Manual. AXFA11G Magnetic Flowmeter Remote Converter [Hardware Edition/Software Edition] IM 01E20C01-01E 9th Edition

User s Manual. AXFA11G Magnetic Flowmeter Remote Converter [Hardware Edition/Software Edition] IM 01E20C01-01E 9th Edition User s Manual AXFA11G Magnetic Flowmeter emote Converter [Hardware Edition/Software Edition] Yokogawa Electric Corporation 9th Edition CONTENTS Contents 1. INTODUCTION... 1-1 1.1 Using the Magnetic Flowmeter

More information

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG GENERAL SPECIFICATION GS.No.GBB323E-5 GENERAL FLOWPET-EG is an OVAL flowmeter primarily intended for use in boiler feed water and fuel oil metering

More information

Technical specification FLUXUS F401 H2O

Technical specification FLUXUS F401 H2O Technical specification Ultrasonic flowmeter for water Portable, very robust and easy-to-use ultrasonic flowmeter for the water and wastewater industry Features Very high bi-directional measuring accuracy

More information

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter Data Sheet D-FMP-10D1475W-Y_4 Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter 10D1475W/Y Flowmeter Systems utilizes a smart microprocessor converter. System accuracy of ±0.5% of

More information

Model Sono-Trak Transit Time

Model Sono-Trak Transit Time Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic

More information

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for

More information

MODEL: M2DYS SEN TRONIC AG

MODEL: M2DYS SEN TRONIC AG Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical

More information

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: M2SES SEN TRONIC AG [3] OUTPUT Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL

More information

MaxxFlow HTC Flow Measurement for Dry Bulk Solids

MaxxFlow HTC Flow Measurement for Dry Bulk Solids EN MaxxFlow HTC Flow Measurement for Dry Bulk Solids Manufactured by Product Information www.onthelevel.com MaxxFlow HTC MaxxFlow HTC MaxxFlow HTC Product Information Use The MaxxFlow HTC was developed

More information

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Sarasota CM200 Sarasota HME900 Density Converter Electronics Sarasota CM00 Sarasota HME00 Density Converter Electronics Users of Sarasota density meters or specific gravity analyzers are offered the choice of a HART compatible, field mounted density converter, or

More information

WATERFLUX 3000 Quick Start

WATERFLUX 3000 Quick Start WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000

More information

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Technical Information TI 273T/02/en 60021667 RTD Temperature Sensor omnigrad T -TSM 480, TR 480 Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Application The Omingrad

More information