General Specifications
|
|
- Erik Moore
- 5 years ago
- Views:
Transcription
1 General Specifications AXFA11 Magnetic Converter for Remote Flowtube The AXFA11 magnetic converter has been developed based on Yokogawa s decades long experience in magnetic flowmeters. The AXFA11 continues the tradition of high quality and reliability that has become synonymous with the Yokogawa name and in addition features an even higher level of performance and increased functionality. Retaining all the features and functions of the Admag series of converters, in addition the AXFA11 offers an enhanced dual frequency excitation method as an option for difficult applications as well as new diagnostics detect electrode coating. Combined with a flowtube utilizing the optional replaceable electrode design, the user benefits through the ability schedule maintenance for reduced process downtime and in turn a lower tal cost of ownership. FEATURES Optional enhanced dual frequency excitation method The user can select a 165 Hz high frequency component for very high concentration slurries ensure greater stability and quicker response. Minimum fluid conductivity of 1 S/cm With the newly designed AXF flow converter, improvements the input circuit now permit the measurement of fluids with conductivity as low as 1 S/cm. Diagnostics detect insulating coatings on the electrodes By constantly moniring the change in the impedance of the electrode circuit due the build-up of insulating coatings, the AXF converter will display 4 different levels of coating and provide an alarm function. Improved accuracy specification The standard performance specification for AXF is.35% of reading. Also available is an optional high accuracy calibration rated at.2% of reading. High speed pulse output The pulse output can be programmed up 1, pulses/ second for high-speed applications such as short batch processes. Easy Setup Parameters The most frequently used parameters are arranged in one location for easy, quick access. STANDARD SPECIFICATIONS Excitation Method: Standard dual frequency excitation: Size mm (.1 16 in.) Combined with AXF Remote Flowtube Enhanced dual frequency excitation: Size 25 2 mm (1. 8. in.) Combined with AXF Remote Flowtube (Option code HF2) Three line display with infrared switches The LCD indicar employs a large, backlit, full dot matrix display. One three lines are available and these can be programmed indicate a wide variety of display possibilities, including a bar graph for flow rate indication and a graphical representation of the extent which the electrodes may be coating. Infrared switches permit programming through the glass without the need open the enclosure cover. Yokogawa Corporation of America 2 Dart Road, Newnan, Georgia Tel.: Fax.: Copyright June 23 5th Edition June 27
2 Input Signal: Two Status Inputs: Dry contact Load resistance: 2 or less (ON), 1 kω or more (OFF) Signals: One Current : 4 2 ma DC (load resistance: 1 kω, including cable resistance) One Pulse : Transisr contact output (open collecr) Contact capacity: 3 V DC (OFF), 2 ma (ON) rate.1 1, pps (pulse/second) One Alarm : Transisr contact output (open collecr) Contact capacity: 3 V DC (OFF), 2 ma (ON) Two Status s: Transisr contact output (open collecr) Contact capacity: 3 V DC (OFF), 2 ma (ON) Communication Signals: BRAIN or HART communication signal (Superimposed on the 4 2 ma DC signal) Communication Line Conditions: Load Resistance: 25 6 Ω (including cable resistance) Distance from Power Line: 15 cm (6 in.) or more (Parallel wiring should be avoided.) BRAIN: Communication Distance: Up 2 km (5 miles), when polyethylene insulated PVC-sheathed cables (CEV cables) are used. Communication distance varies depending on the type of cable and wiring used. Load Resistance: 25 6 Ω including cable resistance Load Capacitance:.22 µf or less Load Inductance: 3.3 mh or less Input Impedance of Communicating Device: 1 kω or more (at 24 khz) HART: Communication Distance: Up 1.5 km (.9 mile), when using multiple twisted pair cables. Communication distance varies depending on the type of cable used. Load Resistance: 25 6 Ω including cable resistance Cable Length for Specific Applications: Use the following formula determine the cable length for specific applications: L (R C) (Cf 1,) C where: L = length in meters or feet R = resistance in Ω (including barrier resistance) C = cable capacitance in pf/m or pf/ft Cf = maximum shunt capacitance of receiving devices in pf/m or pf/ft Note: HART is a registered trademark of the HART Communication Foundation. 2 Data Security During Power Failure: Data (parameters, talizer value, etc.) srage by EEPROM. No back-up battery required. Indicar: Full dot-matrix LCD ( pixels) Lightning Protecr: A lightning protecr is built in the excitation current output, the current output, the signal common, and the pulse/alarm/status input and output terminals. If option code A is selected, the lightning protecr is built in the power terminals. Protection: IP67, NEMA4X Coating: Case and Cover: Polyurethane corrosion-resistant Coating Color: Silver gray (Munsell 3.2PB 7.4/ or its equivalent) Cover Mounting Screws: Polyurethane corrosion-resistant Coating Color: Mint green (Munsell 5.6BG 3.3/2.9 or its equivalent) Converter Material: Case and Cover: Aluminum alloy Mounting: 2-inch pipe, panel or surface mounting Electrical Connection: ANSI 1/2 NPT female Terminal Connection: M4 size screw terminal Grounding: Grounding resistance 1 Ω or less. When option code A is selected, Class C grounding (grounding resistance 1 Ω or less) shall be applied. Converter Interchange: In instances where the AXFA11 converter has been paired with a remote AXF flowtube and the converter is changed the AXFA14 converter, a flow calibration must be performed arrive at the meter facors for the new combination. The AXFA11 converter can be combined with remote flowtubes in sizes mm (.1 14 in.) Functions How Set Parameters: The indicar s LCD and three infra-red switches enable users set parameters without opening the case cover. Parameters can also be set by means of the HHT. Displayed Languages: English, Japanese, German, French, Italian, and Spanish. Instantaneous Flow Rate/Totalized Value Display Functions: The full dot-matrix LCD enables user selection of displays from one line three lines for: Instantaneous flow rate Instantaneous flow rate (%) Instantaneous flow rate (bar graph) Current output value (ma) All Rights Reserved. Copyright 23, Yokogawa Electric Corporation June 27
3 Totalized value Tag No. Results of electrode coating diagnostics Totalizer Display Function: For forward/reverse ranges, the talized values of the flow direction (forward or reverse) and the flow rate are displayed on the indicar gether with the units. The difference values between the forward and reverse flow rate talized values can be displayed. The reverse flow rate is not counted for a forward single range. Damping Time Constant: Time constant can be set from.1 second 2. seconds (63% response). Span Setting Function: Span flows can be set in units such as volume flow rate, mass flow rate, time, or flow rate value. The velocity unit can also be set. Volume Flow Rate Unit: kcf, cf, mcf, Mgal (US), kgal (US), gal (US), mgal (US), kbbl (US)*, bbl (US)*, mbbl (US)*, µbbl (US)*, Ml (megaliter), m 3, kl (kiloliter), l (liter), cm 3 Mass Flow Rate Unit (Density must be set.): klb (US), lb (US), t (n), kg, g Velocity Unit: ft, m (meter) Time Unit: s (sec), min, h (hour), d (day) * US Oil or US Beer can be selected Pulse : Scaled pulse can be output by setting a pulse weight. Pulse Width:Duty 5% or fixed pulse width (.5,.1,.5, 1, 2, 33, 5, 1 ms) can be selected. Rate:.1 1, pps (pulse/second) Multi-range Function: Status input enables the switching of up four ranges. For aumatic range switching, the status of up four ranges can be shown via status outputs and on the indicar. Forward and Reverse Flow Measurement Functions: Flows in both forward and reverse directions can be measured. The status is shown via status outputs and on the indicar during reverse flow measurement. Totalization Switch: If a talized value becomes equal or greater than the set value, a status output is generated. Preset Totalization: A parameter setting or status input enables a talized value be reset a preset value or zero. % Signal Lock: Status input fixes the instantaneous flow rate display, current output, pulse output, and flow rate talization %. Alarm Selection Function: Alarms are classified in System Alarms (hard failures), Process Alarms (such as Empty Pipe, Signal Overflow and Coating Alarm ), Setting Alarms, and Warnings. Whether alarms should be generated or not can be selected for each item. The current output generated for an alarm can be selected from among 2.4 ma or less, fixed 4 ma, 21.6 ma or more, or HOLD. Alarm : Alarms are generated only for the items selected via the Alarm Selection Function if relevant failures occur. Self Diagnostics Functions: If alarms are generated, details of the System Alarms, Process Alarms, Setting Alarms and Warnings are displayed gether with descriptions of countermeasures. Flow Upper/Lower Limit Alarms: If a flow rate is greater or smaller than the set value, this alarm is generated. In addition, two upper limits (H, HH) and two lower limits (L, LL) can be set. If a flow rate is greater or smaller than any of the set values, the status is output. Electrode Coating Diagnostics Function: This function enables moniring of the coating of insulating substances the electrodes. Depending on the status, users are notified by a warning or an alarm via status outputs. If replaceable electrodes are used, they can be removed and cleaned if coating occurs. STANDARD PERFORMANCE Reference Conditions: Similar BS EN 2914 (1993); ISO914 (1991) Fluid Temperature: +1 C +3 C (+5 F +86 F) Ambient Temperature: +2 C +3 C (+68 F +86 F) Warm-up Time: 3 min Straight runs: Upstream > 1 DN Downstream > 5 DN Properly grounded Properly centered (Combined with AXF Remote Flowtube, at reference conditions) Pulse : PFA/Ceramics Lining: Size mm (in.) 2.5 (.1) 15 (.5) 25 (1.) 2 (8.) 25 (1) 4 (16) Flow Velocity V m/s (ft/s) V.3 (1).3 V 1 (1) (33) 1. mm/s V.15 (.5).5 mm/s V.15 (.5).5 mm/s.15 V 1 (.5) (33) V.15 (.5).15 V 1 (.5) (33) Standard (Calibration code B).35% of Rate.35% of Rate.5 mm/s.35% of Rate Flow Velocity V m/s (ft/s).15 V 1.18 (.5) (3.3).2mm/s 1 V 1 (3.3) (33) High grade (Calibration code C).2 T1.EPS Enhanced dual frequency excitation (Option code HF2): Standard accuracy + 1 mm/s 3 All Rights Reserved. Copyright 23, Yokogawa Electric Corporation June 27
4 4 Size 2.5 mm (.1 in.) 15 mm (.5 in.) Pulse High Standard grade Size 25 mm (1. in.) 4 mm (16 in.) F1.EPS 1..8 Standard Pulse.6 High grade F2.EPS Polyurethane Lining Size mm (in.) 25 (1.) 4 (16) 5 (2) 1 (4) 11 (44) 2 (8) 22 (88) 26 (14) Flow Velocity Standard V m/s (ft/s) (Calibration code B) V.3 (1.) 1. mm/s.3 V 1 (1.) (33).35 V.3 (1.) 1.75 mm/s.3 V 1 (1.) (3.3) mm/s 1 V 1 (3.3) (33).35 V.3 (1.) 2.2 mm/s.3 V 1 (1.) (3.3) mm/s 1 V 1 (3.3) (33).5 V 1 (3.3) 8.5 mm/s 1 V 1 (3.3) (33).85 T2.EPS Enhanced dual frequency excitation (Option code HF2): Standard accuracy + 1 mm/s Size 25 mm (1. in.) 4 mm (16 in.) Pulse High Standard grade F3.EPS Size 5 mm (2 in.) 1 mm (4 in.) 1..8 Pulse High Standard grade F16-1.EPS Size 11 mm (44 in.) 2 mm (8 in.) 1..8 Pulse High Standard grade F16-2.EPS Size 22 mm (88 in.) 26 mm (14 in.) Pulse High Standard grade F16-3.EPS Enhanced dual frequency excitation (Combined with AXF Remote Flowtube Optional code HF2): Standard + 1 mm/s Current : Plus.5% of Span Repeatability:.1 (V 1 m/s (3.3 ft/s)) mm/s (V < 1 m/s (3.3 ft/s)) Maximum Power Consumption: Combined with AXF Remote Flowtube: 2 W Insulation Resistance (*1): 1 MΩ between power terminals and ground terminal at 5 V DC 1 MΩ between power terminals and each output/ status input terminal at 5 V DC 2 MΩ between ground terminal and each output/ status input terminal at 1 V DC 2 MΩ between output/status input terminals at 1 V DC All Rights Reserved. Copyright 23, Yokogawa Electric Corporation June 27
5 Withstand Voltage (*1): 135 V AC between power terminals and ground terminal for two seconds 16 V AC between excitation terminals and ground terminal for two seconds 2 V AC between excitation terminals and each output/status input terminal for two seconds CAUTION *1: Before performing the Insulation Resistance Test or the Voltage Breakdown Test, disconnect the ground terminal if the power terminal has a lightning protecr (option code A). Following the relevant test, wait for more than 1 seconds after the power supply has been turned off before removing the cover. After testing, be sure use a resistance for discharge and return the short bar its correct position. Screws must be tightened a rque of 1.18 N-m or more. After closing the cover, the power supply can be resred. Safety Requirement Standards: EN611 Altitude at installation site: Max. 2 m above sea level Installation category based on IEC11: Overvoltage category II ( II applies electrical equipment which is supplied from a fixed installation-like distribution board.) Pollution degree based on IEC11 Pollution degree 2 ( Pollution degree describes the degree which a solid, liquid, or gas which deteriorates dielectric strength or surface resistivity is adhering. 2 applies a normal indoor atmosphere.) EMC Conformity Standards: EN61326 EN61-3-2, EN AS/NZS 264 NORMAL OPERATING CONDITIONS Ambient Temperature: 4 C +6 C ( 4 F +14 F) Indicar s operating range: 2 C +6 C ( 4 F +14 F) Ambient Humidity: 1% Lengthy continuous operation at 95% or more is not recommended. Power Supply: Power supply code 1: AC specifications Rated power supply: 1 24 V AC, 5/6 Hz (Operating voltage range: V AC) DC specifications Rated power supply: 1 12 V DC (Operating voltage range: 9 13 V DC) Vibration Conditions: Level of vibration in conformity with IEC (SAMA ).5 G or less (frequency 5 Hz or less) ACCESSORIES Fuse (T2.5A, 25 V): 1 pc. *Time lag fuse Mounting bracket: 1 set MODEL AND SUFFIX CODE AXFA11 Magnetic Flowmeter Remote Converter: 5 Model Suffix Code Description AXFA11 Use G Magnetic Flowmeter Remote Converter General-Purpose Use For AXF Remote Flowtube of size mm (.1 in. 14 in.) Signal and Communication Power Supply Electrical Connections Indicar -D -E ma DC, BRAIN Communication 4 2 ma DC, HART Communication 1 V 24 V AC or 1 12 V DC ANSI 1/2 NPT female 1 With Indicar / Option code (See the Table of Optional Specifications) T3.EPS Signal Cable: Model AXFC Note: The cable is constructed with double shielding over the two conducrs, and uses heat-resistant vinyl as the outer covering material. Finished diameter: 1.5 mm (.413 in.) Maximum temperature: +8 C (+176 F) Unneccessary order the above cable for submersible type flowtube because the flowtube is wired with 3 m (98 ft) cable. Excitation cable is supplied by the cusmer Recommended Excitation Cable: Use Polyvinyl chloride insulated and sheathed control cable or Polyvinyl chloride insulated and sheathed portable power cables or equivalents. Outer Diameter: mm ( in.) Nominal Cross Section: mm 2 Note: Avoid locations with high vibration (with a vibration frequency of 5 Hz or more), which may cause damage the equipment. All Rights Reserved. Copyright 23, Yokogawa Electric Corporation June 27
6 6 OPTIONAL SPECIFICATIONS FOR AXFA11 REMOTE CONVERTER Item Specification Code Lightning Protecr A lightning protecr is built in the power terminals. Burn Out Down NAMUR NE43 Compliance Active Pulse Stainless Steel Mounting Bracket AM11 Replacement Bracket Stainless Steel Tag Plate Epoxy Resin Coating The output level is set ma during a CPU failure and is set 2.4 ma or less during an alarm. Standard products are delivered with a setting 25 ma during a CPU failure and 21.6 ma or more during an alarm. signal limits: ma Failure alarm down-scale: The output level is set ma during a CPU failure and is set 2.4 ma ( 1%) or less during an alarm. Failure alarm up-scale. The output level is set 25 ma during a CPU failure and is set 21.6 ma (11%) or more during an alarm. Active pulses are output in order drive an external electromagnetic or electronic counter directly using the converter s internal power supply. (Nullfies the standard transisr contact pulse output.) voltage: 24 V DC ±2% Pulse specifications: The drive current of 3 15 ma Pulse rate:.1 2 pps (pulse/second); Pulse width: 2, 33, 5, or 1 ms Provided with a JIS SUS34 (AISI 34 SS/EN equivalent) stainless steel mounting bracket in lieu of the standard carbon steel bracket. Provided with a special mounting bracket for replacing an AM11 converter with an AXFA11. Screwed JIS SUS34 (AISI 34 SS/EN equivalent) stainless steel tag plate. Choose this option when an SS tag plate is required in addition the standard nameplate with the tag number inscribed on it. Epoxy resin coating instead of standard polyurethane resin coating. The color is same as standard type. CSA Mark CSA Mark for general purpose AXF converters and flow tubes. CGP T5.EPS Terminal Configuration I+ I CURRENT OUT SO1+ SO2+ COM STATUS OUT AL+ AL C SA A B SB ALARM OUT SIGNAL SHORT BAR N/ L/+ POWER SUPPLY EX1 EX2 EXCIT ATION P+ P SI1+ SI2+ COM PULSE OUT STATUS IN T6.EPS Terminal Wiring Terminal Symbols SIGNAL ALARM OUT STATUS OUT CURRENT OUT C SA A B SB AL+ AL- SO1+ SO2+ COM I+ I- Description Flow signal input Alarm output Status output (Two output) Current output 4 2mA DC Terminal Symbols STATUS IN PULSE OUT EXCITATION POWER SUPPLY Sl1+ Sl2+ COM P+ P- EX1 EX2 L /+ N/- Description Status input (Two input) Pulse output Excitation current output Power supply Functional grounding Protective grounding (Outside of the terminal) T7.EPS All Rights Reserved. Copyright 23, Yokogawa Electric Corporation June 27
7 7 EXTERNAL DIMENSIONS Remote Converter AXFA11 Pipe mounting 18(7.9) 4-ø6 Hole (Surface mounting hole) 12(4.72) Unit: mm (approx. inch) 65 (2.56) 21(8.27) 194(7.64) (2) (2) (2) (2) (67) (2.64) 24 (.94) (67) (2.64) 29 (1.14) 49 (1.93) Weight 3.2 kg (7.1 lb) Panel mounting 1 1(.4.39) (Panel thickness) 1(3.94) Mounting Screw (M6 1(3.94)) 172(6.77) Panel cuut 23(7.99) 182(7.17) 15 (4.13) R3 MAX Surface mounting *1 Mounting Screw(M6) 18(.71) 65 (2.56) *1: These screws must be provided by user. 194(7.64) 62 (2.44) T8.EPS Remote Converter AXFA11 /RK (AM11 Replacement Bracket) Pipe mounting 133.5(5.26) (2) (2) (2) (2) 49 (1.93) 29 (1.14) 24 (.94) (8.5) (3.17) T9.EPS (8.5) (3.17) Bracket for replacement T1.EPS All Rights Reserved. Copyright 23, Yokogawa Electric Corporation June 27
8 8 Dedicated Signal Cable AXFC-4-L A E B A B 55(2.17) Unit: mm (approx. inch) (5.91) 8(.31)Max (5.91) C G 9(3.54) 9(3.54) F SA SB C (WHITE) (BLACK) (RED) D (WHITE) (BLACK) (RED) CONVERTER 8(.31)Max. 2(.79) L(SPECIFIED LENGTH) AXFC ø1.5(.41) FLOW TUBE Model AXFC-4 D E F G 7(2.76) 25(.98) 5(1.97) 6(2.36) AXFC--L F4.EPS CAP ø1.5(.41) AXFC L(SPECIFIED LENGTH)+34(13.39)(LENGTH for END TREATMENT) F5.EPS ORDERING INFORMATION Note 1: When ordering a remote flowtube and a remote converter, specify the flow span, unit, pulse weight, and talizer display pulse weight. Note 2: Some options, if ordered, require the relevant specifications be supplied. 1. Model, specification and option codes. 2. Tag number Each tag number can be specified up 16 characters in a combination of letters (upper or lower case), numbers, - and.. If specified, the tag number is inscribed on the product s name plate and tag plate (if optional code SCT is selected). For HART procol, up 8 characters can be specified. All Rights Reserved. Copyright 23, Yokogawa Electric Corporation June 27
General Specifications
General Specifications GS 01E20C01-01E AXFA11 Magnetic Flowmeter Converter for Remote Flowtube The AXFA11 magnetic flowmeter high grade converter is a sophisticated product with outstanding reliability
More informationGeneral Specifications
General Specifications GS 1E2C1-1E AXFA11G Magnetic Flowmeter Remote Converter The AXFA11 magnetic flowmeter high grade remote converter is a sophisticated product with outstanding reliability and ease
More informationGeneral Specifications
General Specifications GS 1E22-1E XF14 Magnetic Flowmeter onverter for Remote Flowtube The XF14 magnetic flowmeter converter is a sophisticated product with outstanding reliability and ease of operation,
More informationGeneral Specifications
eneral Specifications S 01E20C02-01E AXA14/C Magnetic lowmeter Remote Converter The AXA14 magnetic flowmeter remote converter is a sophisticated product with outstanding reliability and ease of operation,
More informationGeneral Specifications
eneral Specifications S 01E20C02-01E AXA14/C Magnetic lowmeter Remote Converter The AXA14 magnetic flowmeter remote converter is a sophisticated product with outstanding reliability and ease of operation,
More informationGeneral Specifications
General Specifications EJA530E S-Series Cherry Burrell I Line Sanitary Pressure Transmitter GS 530SCBS-01E The EJA530E S-Series sanitary pressure transmitters combine Yokogawa s EJA-E series in-line pressure
More informationEGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
EGCW Converter for Electromagnetic Flowmeter GENERAL MAGMAX EGCW is the high-performance separate type converter for electromagnetic flowmeters with the compact housing. Improved self-diagnostic functions
More informationGeneral Specifications
General Specifications YTA70 Temperature Transmitter The YTA70 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC
More informationSITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview
Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E
More informationUser's Manual Model SE14 Magnetic Flow Converter
User's Manual Model SE14 Magnetic Flow Converter Manual Change No. 09-001-6E Please use attached sheets for the pages listed below in (7th). Page Page 10-2 EMC Conformity Standards Contents Changed the
More informationIFC 010 Signal Converter
KROHNE 04/2003 7.02347.22.00 GR Signal Converter for electromagnetic flowmeters Easy to install Low-cost signal converter, measuring error < 0.5% of the measured value Easy user-friendly operation Self-monitoring
More informationMagnetic Flowmeter Systems
Series 8700 Magnetic Flowmeter Systems THE 8700 SERIES... Model 8712 C/U - Easiest to use local operator interface and works with any manufacturer s flowtubes Model 8712H/8707 High-Signal System - Pulsed
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationGeneral Specifications
General Specifications GS 01C25F01-01E EJX510A and EJX530A Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJX510A and EJX530A feature single crystal
More informationElectro-Magnetic Flowmeters COPA-XE
Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates
More informationUFM 800 W, C Ultrasonic flowmeter for water and wastewater
KROHNE 08/2000 7.02343.21.00 GR/PRINTO, C Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...withbuilt-on or built-in sensors for open channels Variable area flowmeters
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI
Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track) The transmitter FUS080 is
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationGeneral Specifications
General Specifications YTA110 Temperature Transmitter [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs and converts it to
More informationIntroduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter
Field Intelligent Device Series Electromagnetic Flowmeter Converter LF620,LF622 Introduction Combined with a multi-functional converter LF620 (combined type) or LF622 (separate type) equipped with its
More informationKMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display
Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications
More informationDissolved Oxygen Transmitter
Dissolved Oxygen Transmitter OBM-67H The OBM-67H is a -wire type (4VDC power supply) dissolved oxygen transmitter housed in a robust, die-cast aluminum enclosure suitable for installation out in the field.
More informationOvertravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0
Touch Switch Unique 18 mm Capacitive Touch Switch with Choice of Three Actuators is Activated with Only a Very Slight Physical Contact Lightweight objects, such as thin wire or foil can be accurately detected.
More informationWDM-135A (2-wire type) WDM-136A (4-wire type) CONDUCTIVITY TRANSMITTER. Functions Features. Structure diagram. 10/ cm (note 3) 2-wire system
CONDUCTIVITY TRANSMITTR WDM-A (-wire type) WDM-6A (-wire type) It is a type of small firm aluminum -electrode site-installation CONDUCTIVITY TRANSMITTR (signal transmitter) and easy operate. The device
More informationVersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009
VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet 34-VF-03-14 September 2009 Specification Clamp-on technology HONEYWELL S VERSAFLOW stands for continuity and long term reliability. Flow measurement
More informationGeneral Specifications
General Specifications YTA0, YTA0 Temperature Transmitter [Style: S] The YTA0 and YTA0 are the highly accurate temperature transmitters that accept Thermocouple, RTD, ohms or DC milivolts inputs and converts
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationGeneral Specifications
General Specifications US300FM Ultrasonic Flowmeter GS 01G05B03-01E GENERAL The model US300FM is an ultrasonic flowmeter for measuring liquid flow in a fully filled pipe. With the advanced signal processing
More informationABB Instrumentation. Flowmeter. Specification DataFile
MagMaster Electromagnetic Flowmeter Specification DataFile Process MagMaster for unrivalled flow performance ±0.2% accuracy. Operable flow range of 0:1. Slurry MagMaster for all slurries, pulps and pastes.
More informationSpecifications ELECTROMAGNETIC FLOWMETER. LF664/LF620 LF664/LF to 78 (500 to 1950mm) Overall Specifications TIC-LF664K
Field Intelligent Device Series-Mount Anywhere series-flanged ELECTROMAGNETIC FLOWMETER LF664/LF620 LF664/LF622 20 to 78 (500 to 1950mm) Introduction The electromagnetic flowmeter uses Faraday s Law of
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationKMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display
KMS101W Electromagnetic Wafer Flowmeters with S100 display ideal as resettable/batching meter (sizes: 15mm to 150mm) 0BFEATURES For ADMIXTURE Batching, Shotcrete, Mild-Recycled Water & Selected Chemical
More informationFlow Measurement SITRANS F US Inline
Flowmeter SITRANS FUE80 with CT approval Overview The 2-path flowmeter SITRANS FUE80 comes as battery or mains-powered and is designed to measure water flow in district heating plants, local networks,
More informationRosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS
Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process
More informationSmart Electromagnetic Flowmeter Open channel Flowmeter Detector
No. SS2-MGN200-0200 MagneW3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIEW The MagneW3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter
More informationGeneral Specifications
General Specifications US300FM Ultrasonic Flowmeter GS 01G05B03-01E GENERAL The model US300FM is an ultrasonic flowmeter for measuring liquid flow in a fully filled pipe. With the advanced signal processing
More informationElectromagnetic flowmeters and switches DWM 1000/2000
KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass
More informationGeneral Specifications
General Specifications YTA110 Temperature Transmitter [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs and converts it to
More informationTIDALFLUX 2300 F Technical Datasheet
Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to
More informationUser s Manual. AXFA11G Magnetic Flowmeter Remote Converter [Hardware Edition/Software Edition] IM 01E20C01-01E 7th Edition
User s Manual AXFA11G Magnetic Flowmeter emote Converter [Hardware Edition/Software Edition] Yokogawa Electric Corporation 7th Edition CONTENTS Contents 1. INTODUCTION... 1-1 1.1 Using the Magnetic Flowmeter
More informationModel Sono-Trak Transit Time
Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic
More informationDesign and applications
Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated
More informationAmbient Conditions. Operating Conditions. Pressure
Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version
More informationGeneral Specifications
General Specifications Model YTA110 Temperature Transmitter GS 01C0B01-00E [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs
More informationEN-2018 MAGNETIC FLOW METERS
EN-2018 MAGNETIC FLOW METERS www.meatest.com 1 MEASURING PRINCIPLE Having no moving or mechanical parts in the flow profile electromagnetic flow meters cause no pressure drop, are virtually maintenance
More informationDigital flow transmitter for continuous flow measurement
Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:
More informationMass and Volume Flow Transmitter
IFT9701 Product Data Sheet PS-00218-EU December1999 Mass and Volume Flow Transmitter IFT9701 transmitter The IFT9701 microprocessor-based transmitter works with Micro Motion sensors to provide affordable,
More informationGS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit
High performance microflow Coriolis Flowmeter GENERAL SPECIFICATION GS.No. GENERAL Based on the Coriolis technologies accumulated over many years, the OVAL has broadened its current general purpose coriolis
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More informationWATERFLUX 3000 Quick Start
WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000
More informationI/A Series Mass Flow and Density Meters Model CFT50 Digital Coriolis Mass Flow Transmitter with HART Communication Protocol
Product Specifications I/A Series Mass Flow and Density Meters Model CFT50 Digital Coriolis Mass Flow Transmitter with HART Communication Protocol PSS 1-2B7 A The Model CFT50 Digital Coriolis Mass Flow
More informationSmart Electromagnetic Flowmeter Open channel Flowmeter Detector
Magne3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIE The Magne3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter mainly used for flow
More informationFlow Measurement SITRANS F US Inline
Flowmeter SITRANS FUS80 standard Overview Design The -path design of SITRANS FUS80 ensures maximum accuracy under short inlet conditions. The flowmeter consists of a flow sensor pipe, 4 transducers/transducer
More informationMeasurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080
Overview The transmitter is available in an IP67/NEMA 4X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1-path or -path) FUS80 (-path) FUE80 (-path) The transmitter FUS080 is always
More informationMagnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up
Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically
More informationWATERFLUX 3000 Quick Start
WATERFLUX 3000 Quick Start Electromagnetic flowmeter The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000
More informationManostar Electronic Low Differential Pressure Measurement System
Manostar Electronic Low Differential Pressure Measurement System Manosys Presure Transmitter Intrinsically safe apparatus type Explosion-proof performance iag Intrinsically-safe apparatus is called by
More informationMHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data
Technical documentation Table of content Page 2: Page 3: Page 4: Page 5: Page 6: Page 7: Page 8: Characteristics - applications - technical data Technical data - input quantity - output quantity Electrical
More informationTEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions
Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-352 The Service Information provides the following information: Precautions and safety information Specifications Basic maintenance (cleaning, replacing
More informationHigh Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance
13 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F- Glossary of terms... P.139 Sensor selection guide... P.9~ General precautions... P.1 PHOTO PHOTO
More informationElectromagnetic Flow Transmitter
Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be
More informationConductivity Analyzer
Data Sheet Conductivity Analyzer Comprehensive range of field-proven conductivity cells satisfies broad range of applications. Comprehensive diagnostics facility with in-built software protection ensures
More informationKMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)
KMS502F Electromagnetic Flanged Flowmeters (sizes: 25mm to 200mm) FEATURES: For all your water applications including batching. Flanged connection suites ANSI 150lb flanges. Unsurpassed accuracy to ±0.5%
More informationHigh Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance
1 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1 guide... P.11~ General precautions... P.19 PHOTO PHOTO MEASURE panasonic.net/id/pidsx/global
More informationTechnical specification FLUXUS F401 H2O
Technical specification Ultrasonic flowmeter for water Portable, very robust and easy-to-use ultrasonic flowmeter for the water and wastewater industry Features Very high bi-directional measuring accuracy
More informationGeneral Specifications
General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high
More informationModel Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models
Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model
More informationMODEL: M2SES SEN TRONIC AG [3] OUTPUT
Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL
More informationFlow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview
Siemens AG 2010 Flow Measurement Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the TRANSMAG 2 for pulsed alternating field. These are available as
More informationSeries 1000 and 2000 Transmitters with MVD TM Technology
Series 1000 and 2000 Transmitters with MVD TM Technology Micro Motion Series 1000 and 2000 Transmitters with MVD Technology The new approach to sensor electronics Only Micro Motion combines new MVD Technology
More informationOPTIFLUX 1000 Technical Datasheet
OPTIFLUX 1000 Technical Datasheet Electromagnetic flow sensor in sandwich design Lightweight and compact Excellent price performance ratio Quick and easy to install The documentation is only complete when
More informationPAD - Heavy Duty Differential Pressure Trasmitter
Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:
More informationGeneral Specifications
General Specifications GS 77J0A070E Model VJA7 Distributor (Multifunction) (Isolated Singleoutput and Isolated Dualoutput Types) Overview This plugin type distributor is used in combination with wire type
More informationSITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI
Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the
More informationTechnical Specification FLUXUS ADM 8127B
FLUXUS ADM 8127B Liquid Ultrasonic Flowmeter for Permanent Installation in Hazardous Areas in the Mining Environment FLUXUS ADM 8127B is especially designed for the stationary use in explosive atmosphere
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters
More informationTechnical Information Proline Promag 10P
TI00094D/06/EN/13.17 71385977 Products Solutions Services Technical Information Electromagnetic flowmeter Flow measurement of liquids in chemical or process applications Application Electromagnetic flowmeter
More informationMobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA
Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for
More information600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet
Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration
More informationPROXIMITY SENSOR TERMINOLOGY
Never use this desk reference for installation or operation of equipment. Refer to manual for installation and operation instructions. The following descriptions refer to the European standard EN 60947-5-2.
More informationUTM10 Series Ultrasonic Transit-time Flowmeters
Ultrasonic Transit-time meters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal liquid. The technology has inherent advantages
More informationFlow Measurement SITRANS F M. Flow sensor MAG /49. Overview
Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical
More informationWATERFLUX 3070 Technical Datasheet
WATERFLUX 3070 Technical Datasheet Engineered and manufactured for the water and wastewater industry Highly accurate measurement with extremely short in- and outlet lengths Battery operated, stand alone
More informationApplications Features
GE Measurement & Control TransPort PT878 Panametrics Portable Liquid Ultrasonic Flowmeter Applications The TransPort PT878 portable liquid flowmeter is a complete portable ultrasonic flow metering system
More informationMODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With
Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator 1/1 high resolution Easy adjustment: electronic limiter at the valve open & closed
More information2-Wire. Level Gauge BM 702
KROHNE 09/2001 7.02323.22.00 GR/PRINTO Level Gauge 2-Wire Level-Radar 2-Wire The first and only FMCW Radar Level Gauge with 2-wire technology The non-contact alternative to ageing technologies Maintenance-free
More informationInstruction MI December Magnetic Flow System
Instruction MI 021-138 December 2015 Magnetic Flow System 2800 Series Flowtubes with an 896 or an E96 Transmitter Fault Location Guide Contents Contents...3 Figures...5 Tables...6 Introduction...7 Reference
More informationFlow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview
Flowmeter SITRANS FUS380 standard Overview Design The 2-track design of SITRANS FUS380 ensures maximum accuracy under short inlet conditions. The flowmeter consists of a flow sensor pipe, transducers/transducer
More informationRod probe With coaxial tube reference probe
Capacitive level transmitters GENERAL DESCRIPTION NIVOCAP 2-wire capacitive level transmitters provide an ideal solution for level measurement of conductive or non-conductive liquids. The probe of the
More informationSpecifications. LF450 /LF610 LF450 /LF612 20" to 24" (500 to 600 mm) Field Intelligent Device Series Electromagnetic Flowmeter. Overall Specifications
Field Intelligent Device Series Electromagnetic Flowmeter LF450 /LF610 LF450 /LF612 20" to 24" (500 to 600 mm) Introduction The electromagnetic flowmeter uses Faraday s Law of electromagnetic induction
More informationSubmersible pressure sensor For oils and fuels Model LF-1
Level measurement Submersible pressure sensor For oils and fuels Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems for oils and fuels Overfilling and dry-run
More informationUltrasonic level transmitter, non-contact
Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:
More informationProximity Sensor Terminology
The following descriptions refer to the European standard EN 60947-5-2. of 2007. The specifications given here are intended to be minimum performance values described by the standard. Alignment must not
More informationMODEL: 47LV. Digital Panel Meters 47 Series
Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display
More informationGeneral Specifications
General Specifications GS 01E24A0101EN ADMAG TI Series AXW Magnetic Flowmeter [: 25 to 400 mm (1 to 16 in.)] GENERAL DESCRIPTION The ADMAG TI (Total Insight) series AXW magnetic fl owmeter is a highquality
More informationSubmersible pressure sensor For water and wastewater Model LW-1
Replacement product: Model LF-1 Level measurement Submersible pressure sensor For water and wastewater Model LW-1 WIKA data sheet LM 40.03 Applications Level measurement in rivers and lakes Deep well and
More informationRosemount 8700 Series. Magnetic Flowmeter Systems. Rosemount 8700 Series. Product Data Sheet , Rev TA April 2009.
Product Data Sheet Magnetic Flowmeter Systems THE 8700 E-SERIES... Industry leading performance with standard reference accuracy of 0.25% of rate with an optional High Accuracy of 0.15% of rate. Rosemount
More informationMODEL: MRP6. Final Control Elements
Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator Electrical positioner incorporated 1/1000 high resolution Easy adjustment: electronic
More information