General Specifications

Size: px
Start display at page:

Download "General Specifications"

Transcription

1 General Specifications YTA60 Temperature Transmitter The YTA60 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC or Fieldbus signal for transmission. The YTA60 supports HART and FOUNDATION fieldbus TM communication protocols. HART types are certified as complying with SIL for safety requirement. FEATURES High reliability Dual-compartment housing realizes high resistance capability to harsh environments. Variety of sensor inputs The type of sensor input is user-selectable from thermocouples (T/C), RTDs, ohms, or DC millivolts. Digital communication HART protocol revision is 7 and FOUNDATION fieldbus TM ITK vesion is 6.. The instrument configuration can be changed by the user with using the Fieldmate or Handheld terminal. Local Parameter Setting Parameter configuration by the push button offers easy and quick setup for parameters. Self-diagnostics function Continuous self-diagnostics capability ensures longterm performance and lower cost of ownership. Dual universal inputs Dual input can accept two thermocouple, RTD, ohm or DC millivolt inputs. Differential or average temperature measurement is selectable. The sensor backup function for automatically switches-over from the primary to the backup upon sensor failure. STANDARD SPECIFICATIONS PERFORMANCE SPECIFICATIONS Accuracy HART communication type: A/D accuracy/span + D/A accuracy (See Table on page.) Fieldbus communication type: A/D accuracy (See Table on page.) Cold Junction Compensation Accuracy ± 0. C (± 0.9 F) for T/C only Ambient Temperature Effect (per 0 C change) ±0.% or ±(Temperature coefficient/span), whichever is greater. (See Table on page.) Stability RTD: ±0.% of reading or ±0. C per years, whichever is greater at ± C. T/C: ±0.% of reading or ±0. C per year, whichever is greater at ± C. Year Stability RTD: ±0.% of reading or ±0. C, whichever is greater at ± C. T/C: ±0.% of reading or ±0. C, whichever is greater at ± C. Vibration Effect The YTA60 is tested to the following specifications with no effect on performance per IEC to 60 Hz 0. mm peak displacement 60 to 000 Hz g Power Supply Effect ±0.00% of calibrated span per volt Yokogawa Electric Corporation -9-, Nakacho, Musashino-shi, Tokyo, Japan Tel.: Fax.: Copyright Sep. 06 th Edition Mar. 07

2 FUNCTIONAL SPECIFICATIONS Input Signals Input number: single and dual input Input type is selectable: Thermocouples, -, -, and -wire RTDs, ohms and DC millivolts. See Table. on page. Input Signal Source Resistance (for T/C, mv) kω or lower Input Lead Wire Resistance (for RTD, ohm) 0 Ω per wire or lower Span & Range Limits See Table. on page. Output Signals Two wire to 0 ma DC type Output range:.68 to 0.8 ma HART protocol is superimposed on the to 0 ma signal. Any single value among followings can be selected as the analog output signal. Sensor, Terminal Temperature. Dual input type, same as above plus; Sensor, Average, and Differential Temperature. Also, up to three of the above values can be displayed on LCD display or read via communication. Fieldbus communication type Output signal based on FOUNDATION fieldbus TM communication protocol. Isolation Input/Output/GND isolated to 00V DC Except lightning protector option. Manual Test Output Function The output value can be set manually. Sensor Burnout (HART type) High (.6 ma DC) or Low (.6 ma DC), user selectable. Output in Transmitter Failure (HART type) Down-scale: %,. ma DC or less, sensor burnout.%,.6 ma (Optional code C) Down-scale: %,. ma DC or less (Optional code C) Up-scale: 0%,.6 ma DC or more (Standard or Optional code C) Update Time (HART type) Approximately 0. seconds for a single sensor (0.8 second for dual sensors) at damping time 0 Turn-on Time (HART type) Approximately 6 seconds for a single sensor (7 seconds for dual sensors) Damping Time Constant Selectable from 0 to 00 seconds Self-Diagnostics Self-diagnostic function based on the NAMUR NE07 standard detects failures in the hardware, configuration and communications. Sensor-Diagnostics Sensor failure: Detect the disconnection of sensor. Sensor line information: Measure the line resistance. Sensor drift: Detect the difference between sensor and sensor. Fieldbus Functions (Fieldbus type) Functional specifications for Fieldbus communication conform to the standard specifications (H) of FOUNDATION Fieldbus. Function Block (Fieldbus type) Resource block The resource block contains physical transmitter information. Transducer block The transducer block contains the actual measurement data and information about sensor type and configuration and diagnostics. LCD display block The LCD display block is used to configure the local display, if an LCD display is being used. Analog input (AI) Four independent AI blocks can be selected. Digital input (DI) Four DI function blocks can be used as a limit switch for those temperature. Other function block As other Function blocks, Arithmetic (AR), Signal Characterizer (SC), Input Selector (IS), and two PID function blocks are available. Function block Execution time (ms) AI 0 DI 0 SC 0 IS 0 AR 0 PID Link master function This function enables backup of network manager and local control only by field devices. Alarm function Fieldbus models securely support various alarm functions, such as High/Low alarm, notice of block error, etc. based on FOUNDATION fieldbus specifications. Software download function This function permits to update YTA software via a FOUNDATION fieldbus. Based on Foundation fieldbus specifications (FF88) Download class: Class EMC Conformity Standards EN66- Class A, Table EN66-- EN66-- (for fieldbus) SIL Certification Hart communication type certified in compliance with IEC 608: 00. Functional Safety of Electrical/electronic/ Programmable electronic related systems; SIL capability for single transmitter use SIL capability for dual transmitter use Mar. 07, 07-00

3 Safety Requirement Standards EN600-, C. No.600- Altitude of installation site: Max.,000 m above sea level Installation category: I (Anticipated transient overvoltage 0 V) Pollution degree: Indoor/Outdoor use EN , C. No Measurement category: O (Other) (Measurement Input voltage: 0mVdc max) NORMAL OPERATING CONDITION (Optional features or approval codes may affect limits.) Ambient Temperature Limits 0 to 8 C ( 0 to 8 F) 0 to 80 C ( to 76 F) (with indicator model) Ambient Humidity Limits 0 to 00% RH at 0 C (0 F) Supply Voltage Requirements HART type 0. to V DC for general use and flameproof type 0. to V DC for lightning protector (option code /A) 0. to 0 V DC for intrinsically safe and non-incendive type Minimum voltage limited at 6.6 V DC for digital communications HART With V DC supply, up to a 0Ω load can be used. See graph below. 600 External load resistance 0 R= E Digital Communication range HART PHYSICAL SPECIFICATIONS Enclosure Material & coating Low copper cast aluminum alloy with polyurethane, mint-green paint. (Munsell.6BG./.9 or its equivalent), or ASTM CF-8M Stainless Steel Degrees of protection IP66/IP67, TYPE X Name plate and tag 6 SST Mounting Optional mounting brackets can be used either for two-inch pipe or flat panel mounting. Terminal screws M screws Integral Indicator (with indicator model) -digit numerical display, 6-digit unit display and bar graph. Local Parameter Setting (with indicator model) Parameter configuration by the push button offers easy and quick setup for parameters. Accessible parameters are different with each output cord. Weight Aluminum housing:. kg (.9 lb) without integral indicator and mounting Integral indicator: 0. kg (0. lb) Bracket for horizontal pipe: 0. kg Bracket for vertical pipe:.0 kg Stainless housing:. kg (6.8 lb) without integral indicator and mounting Integral indicator: 0. kg (0.7 lb) Connections Refer to MODEL AND SUFFIX CODE. R(Ω) Power supply voltage E (V) Figure. Relationship Between Power Supply Voltage and External Load Resistance F0E.ai Fieldbus type 9 to V DC for general use, flameproof type, and non-incendive type 9 to 0 V DC for intrinsically safe type 9 to 7. V DC for FISCO field device Communication Requirements Supply Voltage: 9 to V DC Current Draw: Steady state: ma (max) Software download state: ma (max) Load Requirements (HART type) 0 to 90Ω for operation 0 to 600Ω for digital communication Mar. 07, 07-00

4 Table. Sensor type, measurement range, and accuracy T/C RTD Sensor Type B E J K N R S T C W Standard IEC608 ASTM E988 Measurement Range Minimum A/D Accuracy C F Span C F 00 to to to -0-0 to to -0-0 to to -0-0 to 7-00 to -0-0 to 00-0 to 0 0 to to to 0 0 to to -0-0 to 00 0 to to 00 0 to to to to to -0-0 to 900 to 7 7 to 08-8 to -8-8 to 8-8 to -8-8 to 9-8 to -8-8 to 0-8 to -8-8 to 7-8 to to to -8 to to -8 to -8-8 to 7 to 6 6 to 7 to 7 7 to to 6 6 to 7-8 to -8-8 to 6 C ( F) ±.0 ± 0.77 ± 0. ± 0. ± 0. ± 0. ± 0. ± 0. ± 0. ± 0. ±.0 ± 0.7 ± 0. ±.0 ± 0.6 ± 0. ± 0. ± 0.7 ±.0 ± 0.9 ± 0.6 ± 0.7 ±.0 ± 0. ± 0. ±. ±.9 ± 0.7 ± 0.6 ± 0.6 ± 0. ± 0.9 ± 0. ± 0.9 ± 0.7 ±.8 ±.6 ± 0.9 ±.8 ±.08 ± 0.6 ± 0.6 ±.6 ±.8 ±.6 ±.08 ±.6 ±.8 ± 0.6 ± 0. L DIN70 U -00 to to ± 0. ± 0.6 Pt00-00 to 80-8 to 6 ± 0. ± 0. Pt00-00 to 80-8 to 6 ± 0. ± 0. IEC607 Pt00-00 to 80-8 to 6 ± 0.8 ± 0. Pt to 00-8 to 7 0 C ± 0.8 ± 0. JPt00-00 to 00-8 to 9 (8 F) ± 0.6 ± 0.9 Cu0 SAMA RC- -70 to 0-9 to 0 ±. ±. Ni0-70 to 0-9 to 608 ± 0. ± 0. mv -0 to 0 [mv] mv ±0.0 [mv] ohm 0 to 000 [Ω] 0 Ω ±0. [Ω] Note : Total Accuracy = (A/D Accuracy / Span + D/A Accuracy) or (± 0.% of calibrated span), whichever is greater. Accuracy of Fieldbus type: A/D Accuracy. For T/C input, add Cold Junction Compensation Error (± 0. C) to the total accuracy. Example: when selecting Pt00 with measurement range of 0 to 00 C 0. C / 00 C 00% of span +0.0% of span = 0.06% of span Since the value is smaller than ±0.% of span, the total accuracy is ±0.%. Note : T/C C type is same as W (ASTM E988). D/A Accuracy ±0.0% of span Mar. 07, 07-00

5 Table. Temperature coefficient Sensor Type Thermocouples E, J, K, N, T, L, U Thermocouples R, S, W, C Temperature Coefficient 0.08 C + 0.0% of abs.reading 0. C + 0.0% of abs.reading Thermocouple B 00 C Reading < 00 C C + 0.0% of abs.reading RTD mv ohm 00 C Reading 0. C + 0.0% of abs.reading 0.08 C + 0.0% of abs.reading 0.00 mv + 0.0% of abs.reading 0. Ω + 0.0% of reading Note: The abs.reading for thermocouples and RTD means the absolute value of the reading in C. Example of abs.reading When the temperature value is 0 Kelvin, abs.reading is =. Note: Ambient Temperature Effect per 0 C change is ±0.% or ±(temperature coefficient/span), whichever is greater. Example of Ambient Temperature Effect Conditions: ) Input Sensor: Pt00 ) Calibration Range: 00 to 00 C ) Reading value: 0 C Ambient Temperature Effect per 0 C Temperature Coefficient/Span=(0.08 C+0.0/00 0 C )/{00 C ( 00 C)}= % Therefore, Ambient Temperature Effect is ±0.%/0 C Sep. 0, 06-00

6 6 MODEL AND SUFFIX CODES Model Suffix Codes Description YTA Temperature Transmitter Output signal -J F A Always A Sensor input Housing code A C Electrical connection Integral indicator D N Mounting bracket B D J K N Option codes to 0 ma DC with digital communication HART 7protocol Digital communication (FOUNDATION Fieldbus protocol) Single Double Aluminum Stainless G/ female / NPT female M0 female Digital indicator with Local Operating Switch None SUS0 stainless steel -inch horizontal pipe mounting bracket * SUS0 stainless steel -inch vertical pipe mounting bracket SUS6 stainless steel -inch horizontal pipe mounting bracket * SUS6 stainless steel -inch vertical pipe mounting bracket None / Optional specification *: For flat-panel mounting, please prepare bolts and nuts. OPTIONAL SPECIFICATION Item Description Code Lightning protector Allowable current: Max. 6000A(8 0µs), repeating 000A(8 0µs), 00 times A Painting * Color change Munsell code: N. Black P Amplifier cover only Munsell code: 7.BG/., Jade green P Metallic silver P7 Color change Munsell code: 7. R/ Red Amplifier and terminal Covers PR Coating change * High anti-corrosion coating X Output signal low-side in transmitter failure * NAMUR NE compliant * Output signal Low-side: %,. ma DC or less. Sensor burnout is also set to 'Low':.%,.6 ma DC. Output signal limits:.8 ma to 0. ma Failure alarm down-scale: output status at CPU failure and hardware error is %,. ma or less. Sensor burnout is also set to Low:.%,.6 ma DC. Failure alarm up-scale: output status at CPU failure and hardware error is 0%,.6 ma or more. In this case Sensor burnout is High: 0%,.6 ma DC. Data configuration * Description into Descriptor parameter of HART protocol (max. 6 characters) CA Wired tag plate SUS6 stainless steel tag plate wired onto transmitter N Sensor matching RTD sensor matching function CM *: Not applicable for Stainless housing. *: Not applicable for Fieldbus type. *: Not applicable for color change. C C C Sep. 0, 06-00

7 7 OPTIONAL SPECIFICATION (For Explosion Protected type) ATEX Item Description Code -0mA: [Intrinsically safe approval ] Applicable Standard: EN : 0+A:0, EN : 0 Certificate No. FM6ATEX009X II G Ex ia IIC T T Ga Ambient Temperature: 0 to 70 C for T, 0 to 0 C for T Enclosure: IP66/IP67 in accordance with only IEC 609 Supply/Output circuit: Ui=0V, Ii=00mA, Pi=.0W, Ci=nF, Li=0mH Dielectric strength: 00 V a.c.r.m.s., min [+, -, C,,,,, ] to Earth terminal [+, -, C] to [,,,, ] [Flameproof and Dust Ignition Proof Approval] Applicable Standard: EN :0+A:0, EN :0, EN :0 Certificate: KEMA 07ATEX00 II G Ex db IIC T6/T Gb, II D Ex tb IIIC T70 C/T90 C Db Ambient Temperature for Gas Atmospheres: 0 to 7 C for T6, 0 to 80 C for T Ambient Temperature for Dust Atmospheres: 0 to 6 C for T70 C, 0 to 80 C for T90 C Enclosure: IP66/IP67 Electrical Connection: / NPT female and M0 female * Fieldbus: [Intrinsically safe approval ] Applicable Standard: EN : 0+A:0, EN : 0 Certificate No. FM6ATEX009X II G Ex ia IIC T Ga Ambient Temperature: to 60 C Enclosure: IP66/IP67 in accordance with only IEC 609 FISCO field device Supply/Output circuit: Ui=0V, Ii=00mA, Pi=.W, Ci=.nF, Li=0mH Dielectric strength: 00 V a.c.r.m.s., min [+, -,,,,, ] to Earth terminal [+, -] to [,,,, ] [Flameproof and Dust Ignition Proof Approval] Same as KU KU KU Dec., 06-00

8 8 IECEx Item Description Code -0mA: [Intrinsically safe approval] Applicable Standard: IEC : 0, IEC : 0 Certificate No. IECEx FMG 6.00X Ex ia IIC T T Ga Ambient Temperature: 0 to 70 C for T, 0 to 0 C for T Enclosure: IP66/IP67 Supply/Output circuit: Ui=0V, Ii=00mA, Pi=.0W, Ci=nF, Li=0mH Sensor circuit: Uo=6V, Io=90mA, Po=mW, Co=0μF, Lo=.9mH Dielectric strength: 00 V a.c.r.m.s., min [+, -, C,,,,, ] to Earth terminal [+, -, C] to [,,,, ] [Flameproof and Dust Ignition Proof Approval] Applicable standard: IEC :0, IEC :0-06, IEC :0 Certificate: IECEx KEM Ex db IIC T6/T Gb, Ex tb IIIC T70 C/T90 C Db Ambient Temperature for Gas Atmospheres: 0 to 7 C ( 0 to 67 F) for T6, 0 to 80 C ( 0 to 76 F) for T Ambient Temperature for Dust Atmospheres: 0 to 6 C ( to 9 F) for T70 C, 0 to 80 C ( to 76 F) for T90 C Enclosure: IP66/IP67 Electrical Connection: / NPT female and M0 female * Fieldbus: [Intrinsically safe approval] Applicable Standard: IEC : 0, IEC : 0, Certificate No. IECEx FMG 6.00X Ex ia IIC T Ga, Ambient Temperature (Ex ia): to 60 C Ex ic IIC T Gc, Ambient Temperature (Ex ic): 0 to 70 C Enclosure: IP66/IP67 Overvoltage category: I Supply/Output circuit: Ui=0V, Ii=00mA, Pi=.W, Ci=.nF, Li=0mH FISCO field device Sensor circuit: Uo=6V, Io=90mA, Po=mW, Co=0μF, Lo=.9mH Supply/Output circuit: Ui=V, Ci=.nF, Li=0mH FISCO field device Sensor circuit: Uo=6V, Io=90mA, Po=mW, Co=0μF, Lo=.9mH Dielectric strength: 00 V a.c.r.m.s., min [+, -,,,,, ] to Earth terminal [+, -] to [,,,, ] [Flameproof and Dust Ignition Proof Approval] Same as SU SU SU Feb. 8, 07-00

9 9 FM (US) Item Description Code -0mA: [Intrinsically safe approval/non-incendive approval] Applicable standard: Class 600:0, Class 60:0, Class 6:00, Class 80:00, ANSI/ISA :0,ANSI/ISA :0, NEMA 0:00, ANSI/IEC 609:00 (R0) Class I, II, III Division, Groups A, B, C, D, E, F, G, T T Class I Zone 0 AEx ia IIC T T Class I, II, Division, Groups A, B, C, D, F, G, T T Class III, Division T T Class I Zone Group IIC T T Ambient Temperature: 0 to 70 C for T, 0 to 0 C for T Enclosure Type X, IP66/IP67 in accordance with only IEC 609 Supply/Output circuit: Ui=0V, Ii=00mA, Pi=.0W, Ci=nF, Li=0mH Supply/Output circuit: Ui=0V, Ci=nF, Li=0mH Dielectric strength: 00 V a.c.r.m.s., min [+, -, C,,,,, ] to Earth terminal [+, -, C] to [,,,, ] [Explosionproof approval] Applicable standard: Class 600, Class 6, Class 80, ANSI/NEMA0 Class I, Division, Groups A, B, C and D.; Class II/III, Division, Groups E, F and G. "FACTORY SEALD, CONDUIT SEAL NOT REQUIRED." Enclosure Ratings: TYPE X Temperature Class: T6 Ambient Temperature: 0 to 60 C ( 0 to 0 F) Electrical Connection: /NPT female * Fieldbus: [Intrinsically safe approval/non-incendive approval] Applicable standard: Class 600:0, Class 60:0, Class 6:00, Class 80:00, ANSI/ISA :0,ANSI/ISA :0, NEMA 0:00, ANSI/IEC 609:00 (R0) Class I, II, III Division, Groups A, B, C, D, E, F, G T Class I Zone 0 AEx ia IIC T Class I, II, Division, Groups A, B, C, D, F, G T Class III, Division T Class I Zone Group IIC T Ambient Temperature: to 60 C Enclosure Type X, IP66/IP67 in accordance with only IEC 609 FISCO field device Supply/Output circuit: Ui=0V, Ii=00mA, Pi=.W, Ci=.nF, Li=0mH Supply/Output circuit: Ui=V, Ci=.nF, Li=0mH Dielectric strength: 00 V a.c.r.m.s., min [+, -,,,,, ] to Earth terminal [+, -] to [,,,, ] [Explosionproof approval] Same as FU FU FU Dec., 06-00

10 0 CSA * Item Description Code FM (Canada) * -0mA: [Intrinsically safe approval/non-incendive approval] Applicable standard: CAN/CSA-C. No. 0:00 (R0), CAN/CSA-C. No. 9.:007 (R0), CAN/CSA-C. No. 9.:007 (R0), C. No.:987 (R0), CAN /CSA-C. No :0, CAN/CSA-C. No :0, CAN/CSA-C. No. 609:00 (R00), CAN/CSA-C. No. 600-:0, CAN/CSA-C. No :0 Class I, II, III, Division, Groups A, B, C, D, E, F, G, T T Ex ia IIC T T Ga Class I, II, Division, Groups A, B, C, D, F, G T T Class III Division T T Ambient Temperature: 0 to 70 C for T, 0 to 0 C for T Enclosure Type: X, IP66/IP67 in accordance with only IEC 609 Supply/Output circuit: Ui=0V, Ii=00mA, Pi=.0W, Ci=nF, Li=0mH Supply/Output circuit: Ui=0V, Ci=nF, Li=0mH Dielectric strength: 00 V a.c.r.m.s., min [+, -, C,,,,, ] to Earth terminal [+, -, C] to [,,,, ] [Explosionproof approval] Applicable standard: C. No.0, C. No.0., C. No., C. No.0, C. No.9, C. No., C. No.7, C. No., C. No.600- C. No Class I, Groups B, C and D, Class II, Groups E, F and G, Class III. For Class I, Division Groups ABCD Locations FACTORY SEALED, CONDUIT SEAL NOT REQUIRED Enclosure TYPE X Temperature Class: T6 Ambient Temperature: 0 to 60 C Electrical Connection: / NPT female * Fieldbus: [Intrinsically safe approval/non-incendive approval] Applicable standard: CAN/CSA-C. No. 0:00 (R0), CAN/CSA-C. No. 9.:007 (R0), CAN/CSA-C. No. 9.:007 (R0), C. No.:987 (R0), CAN /CSA-C. No :0, CAN/CSA-C. No :0, CAN/CSA-C. No. 609:00 (R00), CAN/CSA-C. No. 600-:0, CAN/CSA-C. No :0 Class I, II, III, Division, Groups A, B, C, D, E, F, G T Ex ia IIC T Ga Class I, II, Division, Groups A, B, C, D, F, G T Class III Division T Ambient Temperature : to 60 C Enclosure Type: X, IP66/IP67 in accordance with only IEC 609 FISCO field device Supply/Output circuit: Ui=0V, Ii=00mA, Pi=.W, Ci=.nF, Li=0mH Supply/Output circuit: Ui=V, Ci=.nF, Li=0mH Dielectric strength: 00 V a.c.r.m.s., min [+, -,,,,, ] to Earth terminal [+, -] to [,,,, ] [Explosionproof approval] Same as CU CU CU Dec., 06-00

11 NEPSI Item Description Code -0mA and Fieldbus: [Flameproof and Dust Ignition Proof Approval] Applicable Standard: GB86.-00, GB86.-00, GB76.-0, GB76.-0 Certificate No. GYJ6.96X Ex d IIC T6/T Gb, Ex td A IP66/IP67 T70 C/T90 C Ambient Temperature for Gas Atmospheres: 0 to 7 C for T6, 0 to 80 C for T Ambient Temperature for Dust Atmospheres: 0 to 6 C for T70 C, 0 to 80 C for T90 C Enclosure: IP66/IP67 Electrical Connection: / NPT female and M0 female * -0mA: [Intrinsically safe approval ] Applicable Standard: GB , GB GB Certificate No. GYJ6.X Ex ia IIC T/T Ga Ambient Temperature: 0 to 70 C for T, 0 to 0 C for T Enclosure: IP66/IP67 in accordance with only IEC 609 Supply/Output circuit: Ui=0V, Ii=00mA, Pi=.0W, Ci=nF, Li=0mH Dielectric strength: 00 V a.c.r.m.s., min [+, -, C,,,,, ] to Earth terminal [+, -, C] to [,,,, ] Fieldbus: [Intrinsically safe approval] Applicable Standard: GB , GB , GB Certificate No. GYJ6.X Ex ia IIC T Ga Ambient Temperature: to 60 C for T Enclosure: IP66/IP67 in accordance with only IEC 609 FISCO field device Supply/Output circuit: Ui=0V, Ii=00mA, Pi=.W, Ci=.nF, Li=0mH Dielectric strength: 00 V a.c.r.m.s., min [+, -,,,,, ] to Earth terminal [+, -] to [,,,, ] *: Applicable for Electrical Connection Code and. *: Applicable for Electrical Connection Code. *: For Explosionproof approval. *: For Intrinsically safe approval/non-incendive approval. NF NS NS Dec., 06-00

12 DIMENSIONS -inch horizontal pipe mounting Unit: mm (Approx. inch) Electrical Connection (Output signal) (.7) Electrical Connection (Input signal) With Indicator (Optional) 6.(.7) 7. (.8) 66.(.60) 8. (0.7) Terminal Cover 6(6.6) 0(.0) Shrouding Bolt (For Explosionproof type) 0 (.7) ø9(.66) Ground Terminal Tag Plate (0.98) Horizontal Pipe Mounting Bracket (Optional) 6(.) -inch pipe ø60.(ø.8) -inch vertical pipe mounting Electrical Connection (Output signal) (.7) Electrical Connection (Input signal) With Indicator (Optional) 6.(.7) 7. (.8) 66.(.60) 8. (0.7) Terminal Cover Shrouding Bolt (For Explosionproof type) ø9(.66) 9.(7.) 09.(8.) 6 (.8) Ground Terminal Tag Plate Vertical Pipe Mounting Bracket (Optional) -inch pipe ø60.(ø.8) 0(.98) 70(.76) 6(.) 98(.86) F0E.ai Dec., 06-00

13 Terminals Communication Terminals Connection hook CHECK METER Connection hook * Input Wiring M0. -deep female for mounting bracket Terminal Configuration Power supply and output terminal External indicator (ammeter) termial * Ground terminal * : When using an external indicator or a check meter, the internal resistance must be 0Ω or less. The hook is not available for Fieldbus communication type. F0E.ai (+) ( ) Thermocouple and DC voltage (A) (B) (B) RTD and resistance (-wire) Single input (A) (B) RTD and resistance (-wire) (A) (A) (B) (B) RTD and resistance (-wire) ( ) (+) (+) Thermocouple and DC voltage (+) ( ) (B) (B) (A) Thermocouple + RTD and resistance (-wire) (A) (B) (B) ( ) (+) Dual input (A) (B) (B) (B) (B) (A) RTD and resistance (-wire) (A) (B) (B) (A) RTD and resistance (-wire) RTD and resistance (-wire) + Thermocouple F0E.ai Dec., 06-00

14 < Ordering Information > Specify the following when ordering Model, suffix codes, and optional codes. If not specified, the instrument is shipped with the settings shown in Table A and B. Specify the following when necessary. -0mA Type (HART Type). Sensor type. For RTD and resistance input, specify the number of wire as well. (Example: Pt00 -wire system) For sensor input code-, specify the type for two inputs. In this case, two engineering values are alternately displayed on the integral indicator with sensor back up DISABLE.. Calibration range and unit ) Calibration range can be specified within the measurement range shown in Table. Also, set the upper limit is larger than the lower limit. ) Specify one range from C, K, F or R for temperature input. It is not necessary to specify the unit of mv and ohm inputs, for these units automatically will be mv or Ω.. Tag Number (if required) Specify Tag number (up to 6 Characters) to be engraved on the tag plate. The specified letters are written on TAG_Name (6 Characters) in the amplifier memory.. Software tag Specified characters (up to characters) are set as Tag (the first 8 characters) and Long tag ( characters) in the amplifier memory. Use alphanumeric capital letters. When the SOFTWARE TAG is not specified, TAG NO is set as Tag (the first 8 characters) and Long tag ( characters) in the amplifier memory.. Other factory configurations Specifying option code CA will allow further configuration at factory. Descriptor (up to 6 characters) 6. Sensor back up Select DISABLE or ENABLE. Fieldbus Type. Sensor type. For RTD and resistance input, specify the number of wire as well. For sensor input code-, specify the type for two inputs. (Example: Pt00 -wire system) In this case, two engineering values are alternately displayed on the integral indicator with sensor back up DISABLE.. Calibration range (XD_SCALE) For sensor input code-, specify the range for two inputs.. Units of calibration range: Specify only one unit from the table, Settings when shipped. For sensor input code-, specify the unit for two inputs.. Output mode (L_TYPE) Select Direct or Indirect.. Output scale (OUT_SCALE) For sensor input code-, specify the scale for two inputs. 6. Output scale unit Specify only one unit from the table, Settings when shipped. For sensor input code-, specify the unit for two inputs. 7. Tag Number Specify Tag number (up to 6 Characters) to be engraved on the tag plate. 8. Software Tag (PD_TAG) Specify software tag (up to Characters) to be written on the amplifier memory. 9. Node Address 0. Operation Functional Class Select BASIC or LINK MASTER.. Sensor back up Select DISABLE or ENABLE. < Factory Setting > Table A. -0mA Type Input sensor type * Wire connection (For RTD) * Calibration range Calibration unit Sensor burnout * Output in Transmitter failure * Sensor backup Tag No. Pt00 or as specified in order -wire system or as specified in order 0 to 00 or as specified in order C or as specified in order High (0%,.6 ma DC) High (0%,.6 ma DC or more) DISABLE or as specified Blank or as specified in order *: For sensor input code-, sensor is set in nonconnection. *: Except when Optional code C or C is specified. Table B. Fieldbus Type Input sensor type * Wire connection (For RTD) * Calibration range * Calibration unit Output Scale * 0 to 00% Output mode Direct Node Address (in hexadecimal) Operation functional Class Sensor backup * Tag Number (Tag plate) Software Tag (PD_TAG) Pt00 or as specified in order -wire system or as specified in order 0 to 00 or as specified in order C or as specified in order 0xF unless otherwise specified in order BASIC, or as specified in order DISABLE or as specified in order Blank or as specified in order TT00 unless otherwise specified in order. *: For sensor input code-, sensor is set in nonconnection. *: Channel settings of AI function blocks depend on sensor backup setting. Disable: AI=Sensor, AI=Terminal temperature Enable: AI=Backup temperature, AI=Terminal temperature Subject to change without notice. Jan. 6, 07-00

General Specifications

General Specifications General Specifications YTA70 Temperature Transmitter The YTA70 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

General Specifications

General Specifications General Specifications YTA60 Temperature Transmitter The YTA60 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

General Specifications

General Specifications General Specifications YTA110 Temperature Transmitter [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs and converts it to

More information

General Specifications

General Specifications General Specifications YTA110 Temperature Transmitter [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs and converts it to

More information

General Specifications

General Specifications General Specifications YTA0, YTA0 Temperature Transmitter [Style: S] The YTA0 and YTA0 are the highly accurate temperature transmitters that accept Thermocouple, RTD, ohms or DC milivolts inputs and converts

More information

General Specifications

General Specifications General Specifications Model YTA110 Temperature Transmitter GS 01C0B01-00E [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs

More information

General Specifications

General Specifications General Specifications EJX Series FOUNDATION TM Fieldbus Communication FOUNDATION fieldbus is the digital communication line for the field instruments, whose signal is internationally standardized by Fieldbus

More information

General Specifications

General Specifications General Specifications GS 01F06F01-01EN Model DY Vortex Flowmeter Model DYA Vortex Flow Converter FOUNDATION Fieldbus Communication Type General FOUNDATION Fieldbus is the digital communication line for

More information

YTA610 and YTA710 Temperature Transmitters (Hardware)

YTA610 and YTA710 Temperature Transmitters (Hardware) User s Manual YTA610 and YTA710 Temperature Transmitters (Hardware) 4th Edition 1 YTA610 and YTA710 Temperature Transmitters (Hardware) 4th Edition CONTENTS 1. Preface... 1-1 Notes on the User s Manual...

More information

General Specifications

General Specifications General Specifications EJA530E S-Series Cherry Burrell I Line Sanitary Pressure Transmitter GS 530SCBS-01E The EJA530E S-Series sanitary pressure transmitters combine Yokogawa s EJA-E series in-line pressure

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

YTA610 and YTA710 Temperature Transmitter (Hardware)

YTA610 and YTA710 Temperature Transmitter (Hardware) User s Manual YTA610 and YTA710 Temperature Transmitter (Hardware) 2nd Edition 1 YTA610 and YTA710 Temperature Transmitter (Hardware) 2nd Edition CONTENTS 1. Preface... 1-1 Notes on the User s Manual...1-1

More information

General Specifications

General Specifications General Specifications EJA510E and EJA530E Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJA510E and EJA530E feature single crystal silicon resonant

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature

More information

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER Configuration Code TM01 Series 642 Programmable HART Field Temperature The Series 642 programmable HART field temperature transmitter is a 2-wire unit with analog output. It includes input for RTDs; resistance

More information

Model 3244MV MultiVariable Temperature Transmitter with Profibus-PA

Model 3244MV MultiVariable Temperature Transmitter with Profibus-PA Easy integration to a Profibus DP network 5-year stability reduces maintenance costs Dual-compartment housing provides the highest reliability in harsh industrial environments 18-bit analog-to-digital

More information

General Specifications

General Specifications General Specifications EJA310E Absolute Pressure Transmitter The high performance absolute transmitter EJA310E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or

More information

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 DOC. NO. : C3200-E04A FM APPROVED Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 APT3200 Smart Pressure Transmitter Standard SST Housing Description of Product The

More information

Rosemount 644 Temperature Transmitter

Rosemount 644 Temperature Transmitter Product Data Sheet 00813-0100-4728, Rev SB Rosemount 644 Temperature Transmitter The Most Versatile Temperature Transmitter Reduce complexity and simplify the day to day operations of your diverse temperature

More information

General Specifications

General Specifications General Specifications EJA440E Gauge Pressure Transmitter The high performance gauge transmitter EJA440E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam.

More information

General Specifications

General Specifications General Specifications EJA120E Differential Pressure Transmitter The high performance draft range differential pressure transmitter EJA120E features single crystal silicon resonant sensor and is suitable

More information

ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE)

ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE) ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE) DATA SHEET FKH...5 The FCX AIII absolute pressure transmitter (Direct mount type) accurately measures absolute pressure and transmits proportional 4 to

More information

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter.   TEMPERATURE. Technology Solutions Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof

More information

General Specifications

General Specifications General Specifications EJA510E and EJA530E Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJA510E and EJA530E feature single crystal silicon resonant

More information

General Specifications

General Specifications General Specifications EJX510A and EJX530A Absolute and Gauge Pressure Transmitter [Style: S2] The high performance absolute and gauge pressure transmitter EJX510A and EJX530A feature single crystal silicon

More information

General Specifications

General Specifications General Specifications EJA120E Differential Pressure Transmitter The high performance draft range differential pressure transmitter EJA120E features single crystal silicon resonant sensor and is suitable

More information

General Specifications

General Specifications General Specifications EJA440E Gauge Pressure Transmitter The high performance gauge transmitter EJA440E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam.

More information

DPharp Differential Pressure and Pressure Transmitters

DPharp Differential Pressure and Pressure Transmitters User s Manual DPharp Differential Pressure and Pressure s Manual Change No. 12-021-2 For the products of EJX and EJA-E series with any of the following option codes, please refer to this manual change

More information

General Specifications

General Specifications General Specifications EJX310A Absolute Pressure Transmitter [Style: S2] The high performance absolute transmitter EJX310A features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications GS 01C25F01-01E EJX510A and EJX530A Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJX510A and EJX530A feature single crystal

More information

General Specifications

General Specifications General Specifications EJX440A Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJX440A features single crystal silicon resonant sensor and is suitable to measure liquid, gas,

More information

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

STT 3000 Smart Temperature Transmitter Series STT170 Specifications STT 3000 Smart Temperature Transmitter Series STT170 Specifications Model STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 November 2010 Overview STT17H Features The Honeywell STT170 series of programmable

More information

Model 3244MV. MultiVariable Temperature Transmitter with Profibus PA. Product Data Sheet

Model 3244MV. MultiVariable Temperature Transmitter with Profibus PA. Product Data Sheet Product Data Sheet 00813-0100-4799 Model 3244MV MultiVariable Temperature Transmitter with Profibus PA PROFIBUS PA CAPABILITIES CanbeintegratedtoaProfibusDPnetwork Reduces wiring costs and installation

More information

General Specifications

General Specifications General Specifications EJA130E Differential Pressure Transmitter The high performance differential transmitter EJA130E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJX120A Differential Pressure Transmitter The high performance draft range differential pressure transmitter EJX120A features single crystal silicon resonant sensor and is suitable

More information

General Specifications

General Specifications General Specifications EJX310A Absolute Pressure Transmitter [Style: S2] The high performance absolute transmitter EJX310A features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJA510E and EJA530E Absolute and Gauge Pressure Transmitter [Style: S2] The high performance absolute and gauge pressure transmitter EJA510E and EJA530E feature single crystal silicon

More information

General Specifications

General Specifications General Specifications EJA310E Absolute Pressure Transmitter [Style: S2] The high performance absolute transmitter EJA310E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

SMART TEMPERATURE TRANSMITTERS. smar

SMART TEMPERATURE TRANSMITTERS. smar SMART TEMPERATURE TRANSMITTERS FEATURES Single unit accepts signal from: - Standart RTDs and Thermocouples - Single ended or differential sensing - mv signals from radiation pyrometers, load cells, etc.

More information

0 2 1 â Ó. itemp HART TMT182. Technical Information

0 2 1 â Ó. itemp HART TMT182. Technical Information Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for

More information

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.

More information

General Specifications

General Specifications General Specifications EJX120A Differential Pressure Transmitter The high performance draft range differential pressure transmitter EJX120A features single crystal silicon resonant sensor and is suitable

More information

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process

More information

General Specifications

General Specifications General Specifications EJX130A Differential Pressure Transmitter [Style: S2] The high performance differential transmitter EJX130A features single crystal silicon resonant sensor and is suitable to measure

More information

General Specifications

General Specifications General Specifications EJA130E Differential Pressure Transmitter [Style: S2] The high performance differential transmitter EJA130E features single crystal silicon resonant sensor and is suitable to measure

More information

General Specifications

General Specifications General Specifications EJX310A Absolute Pressure Transmitter [Style: S2] The high performance absolute transmitter EJX310A features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJX430A Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJX430A features single crystal silicon resonant sensor and is suitable to measure liquid, gas,

More information

General Specifications

General Specifications General Specifications EJA440E Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJA440E features single crystal silicon resonant sensor and is suitable to measure liquid, gas,

More information

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL WITH DIAPHRAGM SEAL APT3200L Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate Fuel Autrol America

More information

General Specifications

General Specifications General Specifications EJX430A Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJX430A features single crystal silicon resonant sensor and is suitable to measure liquid, gas,

More information

General Specifications

General Specifications General Specifications GS 01C25F01-01E EJX510A and EJX530A Absolute and Gauge Pressure Transmitter [Style: S2] The high performance absolute and gauge pressure transmitter EJX510A and EJX530A feature single

More information

Rosemount 648 Wireless Temperature Transmitter

Rosemount 648 Wireless Temperature Transmitter Rosemount 648 Wireless Temperature Transmitter with Rosemount X-well Technology Product Data Sheet July 2016 00813-0100-4648 Rev GD Rosemount X-well Technology provides accurate process temperature without

More information

Rosemount 248 Wireless Temperature Transmitter

Rosemount 248 Wireless Temperature Transmitter Rosemount 248 Wireless Temperature Transmitter Product Data Sheet November 2014 00813-0100-4248, Rev CC Standard temperature transmitter offers a wireless solution for process monitoring Optimize plant

More information

The Rosemount 848T Wireless Temperature Transmitter

The Rosemount 848T Wireless Temperature Transmitter Rosemount 88T Family February 0 The Rosemount 88T Wireless Temperature Transmitter The Rosemount 88T is the premier choice for Wireless High Density measurements. Four independently configurable inputs

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. NO. : C3200-E05A Smart Pressure Transmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 Duon System Co.,Ltd. www.autrol.com AUTROL, AUTROL are trade mark of smart transmitter brand series

More information

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable) Specification Sheet 600T Series Transmitters Model 65T Electronic temperature transmitter (PC programmable) High flexibility and wide rangeability Single transmitter accepts RTD/THC/mV/ohm Galvanically

More information

Rosemount 148 Temperature Transmitter

Rosemount 148 Temperature Transmitter Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement

More information

Rosemount 248 Temperature Transmitter

Rosemount 248 Temperature Transmitter Rosemount 248 Rosemount 248 Temperature Transmitter Basic temperature transmitter offers a reliable solution for temperature monitoring points transmitter design provides flexible and reliable performance

More information

General Specifications

General Specifications General Specifications EJA110E Differential Pressure Transmitter The high performance differential transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications YFGW510 Field Wireless Access Point GS 01W02E01-01EN GENERAL This General Specification(GS) describes the hardware specifications for Field Wireless Access Point and specifications

More information

Rosemount 248 Temperature Transmitter

Rosemount 248 Temperature Transmitter Product Data Sheet Rosemount 248 Rosemount 248 Temperature Transmitter Ready-to-install out of the box Unsurpassed performance for temperature monitoring points Industry standard DIN Form B headmount transmitter

More information

General Specifications

General Specifications General Specifications EJX110A Differential Pressure Transmitter [Style: S3] The high performance differential transmitter EJX110A features single crystal silicon resonant sensor and is suitable to measure

More information

General Specifications

General Specifications General Specifications EJX115A Low Flow Transmitter [Style: S1] The low flow transmitter EJX115A is a differential transmitter assembled with an integral orifice and excellent for very low flow measurement.

More information

General Specifications

General Specifications General Specifications EJX510B and EJX530B Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitters EJX510B and EJX530B feature single crystal silicon resonant

More information

Head mounted Temperature Transmitter TF02/TF02-Ex

Head mounted Temperature Transmitter TF02/TF02-Ex Data Sheet Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit) Thermocouples Resistance

More information

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: M2XU MODEL: M2XU [1][2] [3][4] Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and

More information

Rosemount 648 Wireless Temperature Transmitter

Rosemount 648 Wireless Temperature Transmitter Rosemount 648 Wireless Temperature Transmitter Product Data Sheet September 2014 00813-0100-4648, Rev GA Industry-leading temperature transmitter delivers field reliability as a wireless measurement solution.

More information

Rosemount 644 Temperature Transmitter

Rosemount 644 Temperature Transmitter Rosemount 644 Rosemount 644 Temperature Transmitter Communicates easily using either 4-20 ma/hart or FOUNDATION fieldbus protocol Meets NAMUR NE 21 recommendation ensuring reliable transmitter performance

More information

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer

More information

General Specifications

General Specifications General Specifications FN510 Field Wireless Multi-Function Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Multi-Function Module. Combined with Field Wireless

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters

AT9000 Advanced Transmitter Gauge Pressure Transmitters AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability. Capable

More information

General Specifications

General Specifications General Specifications EJA110E Differential Pressure Transmitter The high performance differential transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications YFGW510 Field Wireless Access Point GS 01W02E01-01EN GENERAL This General Specification(GS) describes the hardware specifications for Field Wireless Access Point and specifications

More information

General Specifications

General Specifications General Specifications YFGW510 Field Wireless Access Point GS 01W02E01-01EN GENERAL This General Specification(GS) describes the hardware specifications for Field Wireless Management Station and specifications

More information

Alphaline Temperature Transmitters

Alphaline Temperature Transmitters Alphaline Temperature Transmitters Accepts RTD and thermocouple inputs Available with an integral meter Dual compartment housing provides the highest reliability in harsh industrial environments Offers

More information

Rosemount 148 Temperature Transmitter

Rosemount 148 Temperature Transmitter Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Basic temperature transmitter offers a cost-effective solution for temperature monitoring points transmitter design provides flexible

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

General Specifications

General Specifications General Specifications EJX430A Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJX430A features single crystal silicon resonant sensor and is suitable to measure liquid, gas,

More information

0 2 1 â Ó. itemp HART TMT182. Technical Information

0 2 1 â Ó. itemp HART TMT182. Technical Information Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters

AT9000 Advanced Transmitter Gauge Pressure Transmitters AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability. Capable

More information

General Specifications

General Specifications General Specifications YTMX580 Multi-Input Temperature Transmitter GS 04R01B01-01EN The model YTMX580 Multi-Input Temperature Transmitter can accept inputs from up to 8 points of measurement such as thermocouples

More information

FIELD DEVICES TEMPERATURE

FIELD DEVICES TEMPERATURE FIELD DEVICES TEMPERATURE Product Specifications Model RT I/A Series Temperature Transmitter with HART 7 Communication Protocol and Optional SIL Certification The Model RTT80 is a microprocessor-based

More information

General Specifications

General Specifications General Specifications YFGW520 Field Wireless Access Point GS 01W02E02-01EN GENERAL This General Specification(GS) describes the hardware specifications for Field Wireless Access Point and specifications

More information

General Specifications

General Specifications General Specifications GS 01C25J03-01EN EJX438A Diaphragm Sealed Gauge Pressure Transmitter [Style: S2] Diaphragm seal is used to prevent process medium form entering directly into the -sensing assembly

More information

FIELD DEVICES TEMPERATURE

FIELD DEVICES TEMPERATURE FIELD DEVICES TEMPERATURE Product Specifications Model RTT80 I/A Series Temperature Transmitter with HART 7 Communication Protocol and Optional SIL Certification PSS 2A-1F8 A The Foxboro brand Model RTT80

More information

Rosemount 248 Wireless Temperature Transmitter

Rosemount 248 Wireless Temperature Transmitter Product Data Sheet temperature transmitter offers a wireless solution for process monitoring Optimize plant efficiency and increase measurement reliability with industry-proven capabilities and specifications

More information

Rosemount 5400 Series Radar Level Transmitter

Rosemount 5400 Series Radar Level Transmitter Radar Level Transmitter Start Step 1: Mount the Transmitter Step 2: Connect the Wiring Step 3: Configure Confirm Configuration End HART 00825-0100-4026I www.rosemount.com 2007 Rosemount Inc. All rights

More information

Rosemount 648 Wireless Temperature Transmitter

Rosemount 648 Wireless Temperature Transmitter Product Data Sheet Rosemount 648 Rosemount 648 Wireless Temperature Transmitter Industry-leading temperature transmitter delivers field reliability as a wireless measurement solution Achieve optimal efficiency

More information

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52 Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 6 Applications Process engineering Plant construction General

More information

AT9000 Advanced Transmitter Differential Pressure Transmitters

AT9000 Advanced Transmitter Differential Pressure Transmitters AT9000 Advanced Transmitter Differential Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability. Capable

More information

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration

More information

STT 3000 Smart Temperature Transmitter

STT 3000 Smart Temperature Transmitter STT 3000 Smart Temperature Transmitter Foundation TM Fieldbus Model STT35F Introduction EN0I-6083 April 2009 Specification and Model Selection Guide Honeywell s microprocessor based STT35F Smart Temperature

More information

TIY Programmable, Isolated Thermocouple Transmitter combines

TIY Programmable, Isolated Thermocouple Transmitter combines April 2016 Description Moore Industries unique digital/analog hybrid the combines smart digital technology with advanced analog operation to deliver superior reliability, accuracy and ease of use. Microprocessor-based,

More information

General Specifications

General Specifications General Specifications EJA110E Differential Pressure Transmitter The high performance differential transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily

More information

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. TTF200 Field-mount temperature transmitter

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. TTF200 Field-mount temperature transmitter ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET TTF200 Field-mount temperature transmitter 2 TTF200 FIELD-MOUNT TEMPERATURE TRANSMITTER DS/TTF200-EN REV. B Measurement made easy Temperature transmitter

More information

MODEL: R30US4. Remote I/O R30 Series

MODEL: R30US4. Remote I/O R30 Series Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable

More information

Rosemount 148 Temperature Transmitter

Rosemount 148 Temperature Transmitter Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Ready-to-install solution for temperature monitoring applications Increased measurement accuracy and reliability Accepts 2-, 3-, and

More information