Medium Voltage VFD MVC Series. 200kW to 40MW 2.3kV to 18kV
|
|
- Kory Jordan
- 5 years ago
- Views:
Transcription
1 Medium Voltage VFD MVC Series 200kW to 40MW 2.3kV to 18kV
2
3
4 Milestones 32MVA MV-VFD system for an LNG 2013 compressor motor MVA MV-VFD system for a compressor motor drive Multi-drive for a coal conveyor in China First & Largest AMP converter in China Largest four-quadrant variable frequency converter for a Motor Test Bench in China. First Chinese manufactured equipment used in the starting of large-capacity pumped-storage units. Largest VFD used for a motor test bench in China. First MV-VFD for an Oil Shales ATP Furnace in China. First MV-VFD for a Synchronous Machine in China. First H-Bridge Multi-Level 4-Q MV-VFD for a Hoist Machine in China V Explosion-proof VFD
5 General Specifications 05 RMVC 4000 series RMVC 5000 series RMVC 6000 series RMVC 8000 series Product List RMVC Smart Company Information 35 37
6 Energy-Saving Efficiency-Improving Engineering Your Solutions
7 Cascaded H-Bridge Vector Control Based on IGBT & IEGT 2-Quadrant & 4-Quadrant
8 Multi Winding Phase Shifting Multi-Pulse Rectifier
9 Modular Design AC-DC-AC PWM Control Ease of Maintenance Based on TI-DSP Digital Control Modbus/Profibus/TCP
10 The input terminals R, S, T are connected to the low voltage output terminals of the transformers secondary winding. The DC voltage is formed after being rectified by a three phase full-wave bridge rectifier and filtered by capacitors, this supplies the H bridge inverter circuit which consists of IGBT power cell modules using PWM control technology. The switch on and off actions of A+, A-, B+ & B- are controlled by fibre optic trigger signals. This is how the output voltage wave is formed. The DC voltage is formed after being rectified by a three phase full-wave IGBT bridge rectifier and filtered by capacitors, this supplies the H bridge inverter circuit which consists of IGBT power cell modules using PWM control technology. The switch on and off actions of A+, A-, B+ & B- are controlled by fibre optic trigger signals. This is how the output voltage wave is formed. Through control of the IGBT's, the energy from the load side is fedback to the grid side.
11 The waveform is formed from 5 power cells in this example. Excellent sinusoidal waveform and low dv/dt Output harmonic filter is unnecessary Suitable for many types of AC motors
12
13
14
15
16 RMVC 4000 Series is suitable for most applications, such as precise control, heavy load, high altitude environment, high temperature climate, etc. It can also be designed with 4-Q and cell bypass functions.
17 Sensorless speed vector control Synchronous motor/asynchronous motor control mode Improved self-diagnosis function Two-live control power supplies and soft pre-charging system Synchronized grid connection function Flying start function Master-slave control
18
19
20 RMVC 5000 Series uses a compact structure. Especially suited to limited space applications.
21 Sensorless speed vector control Asynchronous motor control mode Improved self-diagnosis function Two-live control power supplies and a soft pre-charging system Flying start function Uses film capacitors
22
23
24 AMP equipment is used to supply power to docked ships, providing clean energy and creating a "Green Port" VSG is used as a special power supply with a specified voltage, frequency and harmonic, for detecting the capacity of LVRT of wind power convertor and photovoltaic inventor.
25 HVDC with var compensation is used for remote area passive network power supplies, offshore drilling platform power supplies, renewable energy grid connections, etc. PPS is used to provide different types of voltages and frequencies to test benches for testing motors, pumps and transformers.
26
27
28 MVC 8000 Series has been specially developed to drive very large motors, with power ratings of, 18MW, 20MW 25MW, 30MW, 40MW, etc.
29 IEGT based power electronics Vector control Water cooling with remove space Controller redundancy Suitable for a brushless synchronous motor
30
31
32
33 RMVC 6000 and RMVC 8000 units are customized according to customer requirements. Please contact us for details.
34 33
35 34
36 Offers unique voltage and frequency stepping soft starting. Output 12.5Hz/15Hz, 25Hz/30Hz and 50Hz/60Hz. Small starting current with a high starting torque. Excellent for high load starting. Variety of configurational options for multi-motor starting Available with or without an integrated bypass contactor inside. Reduces water hammer, site voltage and energy consumption.
37 Uses Heat-Pipe technology Voltage rating, 660V/1140V Power rating, 75kW~400kW, <2000kW Can be containerised Voltage rating 270V/400V/690V Power rating 50kW, 250kW, 500kW, 1000kW
38
39
40 RXPE Group RXPE Drive Tech. Co., Ltd RXPE (Shanghai Office) Address: Keji Road Science & Technology High-Tech Zone Anshan, Liaoning Province, China Address: SiFangTai Road TieXi District Development Zone Anshan, Liaoning Province, China Address: 17Floor, No.366, Zhaojiabang Road Xuhui District, Shanghai, China Tel: Fax: Post code:
Meduim Voltage Drives
YANTRA HARVEST Meduim Voltage Drives YANTRA HARVEST ENERGY PVT. LTD. Office No. 101, 102, 103, Plot No. 84, Survey No. 40, Ambedkar Road, Sangamwadi, Near RTO Office, Pune - 411001 (India) Tel / Fax :
More informationSolid State Transformers (SST)
Solid State Transformers (SST) Classical Transformer Classical Transformer Classical Transformer Classical Transformer Higher Frequency Lower Volume Solid State Transformer The SS is one of the key elements
More informationUniverter-MV. Medium Voltage Variable Speed Drive
Univerter-MV Medium Voltage Variable Speed Drive Capabilities CSE-Uniserve Pty Ltd has been a leading supplier of variable speed drives to the Australian market since 1984. During this period CSE- Uniserve
More informationB.Tech Academic Projects EEE (Simulation)
B.Tech Academic Projects EEE (Simulation) Head office: 2 nd floor, Solitaire plaza, beside Image Hospital, Ameerpet Ameerpet : 040-44433434, email id : info@kresttechnology.com Dilsukhnagar : 9000404181,
More informationMedium Voltage Drives in Industrial Applications. By: Navid Zargari & Steven Rizzo Rockwell Automation Cambridge, ON
Medium Voltage Drives in Industrial Applications By: Navid Zargari & Steven Rizzo Rockwell Automation Cambridge, ON Outline Introduction Medium Voltage Drive Topologies A Brief Comparison Power Semiconductors
More informationTMdrive -XL Series Family Product Application Guide. solar inverters. power generation
TMdrive -XL Series Family Product Application Guide metals cranes mining testing oil & gas solar inverters power generation cement TMdrive-XL Series 8 MVA 15 MVA 20 MVA 30 MVA The TMdrive XL series family
More informationRongxin Power Electronic Co.,Ltd. SVG STATIC VAR GENERATOR
Rongxin Power Electronic Co.,Ltd. SVG STATIC VAR GENERATOR 01 The biggest 66kV/10000kVA HV power station for SVG test in China 02 Advanced full automatic SMT production Line 03 Most self-contained all
More informationPart Five. High-Power ac Drives
Part Five High-Power ac Drives Chapter 12 Voltage Source Inverter-Fed Drives 12.1 INTRODUCTION The voltage source inverter-fed medium-voltage (MV) drives have found wide application in industry. These
More informationTHE GUIDELINE TO ELECTRIC PROPULSION
THE GUIDELINE TO ELECTRIC PROPULSION STADT STASCHO is a No Loss AC drive that supplies sinusoidal voltage and current to the electric motor and back to the main switchboard. This gives very low harmonic
More informationHarmonics White Paper
Harmonics White Paper New Breakthrough In PWM Drives Technology Reduces Input Line Harmonics Without the Use of Filtering Devices Harmonic Distortion Damages Equipment and Creates a Host of Other Problems
More informationMedium Voltage VFD. Perfect Energy Saving Drive 3kV 200kVA ~ 3,700kVA / 4kV 250kVA ~ 4,700kVA 6kV 400kVA ~ 7,500kVA / 10kV 600kVA ~ 11,000kVA
www.miepl.com/ls Medium Voltage VFD Perfect Energy Saving Drive 3kV 200kVA ~ 3,700kVA / 4kV 250kVA ~ 4,700kVA 6kV 400kVA ~ 7,500kVA / 10kV kva ~ 11,000kVA Perfect Energy Saving Drive The most efficiency
More informationA COMPARITIVE STUDY OF THREE LEVEL INVERTER USING VARIOUS TOPOLOGIES
A COMPARITIVE STUDY OF THREE LEVEL INVERTER USING VARIOUS TOPOLOGIES Swathy C S 1, Jincy Mariam James 2 and Sherin Rachel chacko 3 1 Assistant Professor, Dept. of EEE, Sree Buddha College of Engineering
More informationCHAPTER 3 A COMPARISON OF MULTILEVEL INVERTER USING IN 3-PHASE INDUCTION MOTOR
44 CHAPTER 3 A COMPARION OF MULTILEVEL INVERTER UING IN 3-PHAE INDUCTION MOTOR 3.1 Introduction Now a days the use of multi-level inverters are increasing day to day life and they playing a vital role
More informationOBICON. Perfect Harmony. Short overview. ROBICON Perfect Harmony. System Overview. The Topology. The System. ProToPS. Motors.
and Drives Control R Interface OBICON Perfect Harmony Short overview 14.03.2007 1 System overview Product features Truly Scaleable Technology 300 kw to 30 MW (Single Channel) Large Number of Framesizes
More informationDrives 101 Lesson 3. Parts of a Variable Frequency Drive (VFD)
Drives 101 Lesson 3 Parts of a Variable Frequency Drive (VFD) This lesson covers the parts that make up the Variable Frequency Drive (VFD) and describes the basic operation of each part. Here is the basics
More informationTOSHIBA MITSUBISHI-ELECTRIC INDUSTRIAL SYSTEMS CORPORATION
TMdrive AC/DC DRIVE Series New Dr ive Generation for All Applications TOSHIBA MITSUBISHI-ELECTRIC INDUSTRIAL SYSTEMS CORPORATION TMEIC (Toshiba Mitsubishi-Electric Industrial Systems Corporation) as a
More informationPower Converter Systems
Power Converter Systems Bin Wu PhD, PEng Professor ELCE Department Ryerson University Contact Info Office: ENG328 Tel: (416) 979-5000 ext: 6484 Email: bwu@ee.ryerson.ca http://www.ee.ryerson.ca/~bwu/ Graduate
More informationInnovations in Drive Technologies. High-availability, medium-voltage, variable speed drives for pumping and compression
Innovations in Drive Technologies High-availability, medium-voltage, variable speed drives for pumping and compression Siemens AG 2015. 2013. All rights reserved. Common MV VSD topologies LCI PWM 3 level
More informationFrequently Asked Questions (FAQs) MV1000 Drive
QUESTION 1. What is a conventional PWM Inverter? 2. What is a medium voltage inverter? 3. Are all MV inverters Voltage Source (VSI) design? 4. What is a Current Source Inverter (CSI)? 5. What output power
More informationLarge PWM Inverters for Rolling Mills
Large PWM Inverters for Rolling Mills Hiromi Hosoda Sumiyasu Kodama Toshiba Mitsubishi Electric Industrial Systems Corporation Toshiba Mitsubishi Electric Industrial Systems Corporation Drive Systems Department
More informationHigh performance intelligent power module for PWM rectifier. application
High performance intelligent power module for PWM rectifier application Sun Jian, Mitsubishi Electric & Electronics (Shanghai) Co., Ltd. China Li wenqing, Dalian GONA technology engineering Co., Ltd. China
More informationDevelopment of Transformerless Multi-Level Medium Voltage Inverters
New Technologies Development of Transformerless Multi-Level Medium Voltage Inverters Isamu Hasegawa, Shizunori Hamada, Kenji Kobori, Yutaka Shoji Keywords Multi-level inverter, PWM, Transformerless Abstract
More informationDesign of Five-Level Bidirectional Hybrid Inverter for High-Power Applications
Design of Five-Level Bidirectional Hybrid Inverter for High-Power Applications Abstract: multi-level inverters are best suitable for high-power applications. This paper is devoted to the investigation
More informationAMV-I Medium Voltage Inverter Manual
R AMV-I Medium Voltage Inverter Manual AMV-I INVERTER Summar y AMVI series medium-voltage inverter, produced by AUBO Electric Co. Ltd, is a high tech product with our own intellectual property rights and
More informationSAMCon High Voltage Shore Connection System On-shore and Onboard
High Voltage Shore Connection System On-shore and Onboard Emission-free Power Supply High Voltage On-shore Power Supply System (OPS) There is increasing pressure on shipping operators and port authorities
More informationPOWER ISIPO 29 ISIPO 27
SI NO. TOPICS FIELD ISIPO 01 A Low-Cost Digital Control Scheme for Brushless DC Motor Drives in Domestic Applications ISIPO 02 A Three-Level Full-Bridge Zero-Voltage Zero-Current Switching With a Simplified
More informationTDE MACNO Spa. AC&DC Drives, Servos and Drive System. AFE converters for Renewable Energies Regenerative (active) power supply (Active Front End)
TDE MACNO Spa AC&DC Drives, Servos and Drive System AFE converters for Renewable Energies Regenerative (active) power supply (Active Front End) Automation and Control Systems OPENDRIVE EXP MINI OPENDRIVE
More informationThe University of Nottingham
The University of Nottingham Power Electronic Converters for HVDC Applications Prof Pat Wheeler Power Electronics, Machines and Control (PEMC) Group UNIVERSITY OF NOTTINGHAM, UK Email pat.wheeler@nottingham.ac.uk
More informationTMdrive -XL85 Product Application Guide. Medium Voltage 5-Level Drive
TMdrive -XL85 Product Application Guide Medium Voltage 5-Level Drive metals cranes mining testing oil & gas solar inverters utilities cement TMdrive-XL85 High-Power Drive Electric Compressor Drive Application
More informationVARIABLE FREQUENCY DRIVE
VARIABLE FREQUENCY DRIVE Yatindra Lohomi 1, Nishank Nama 2, Umesh Kumar 3, Nosheen aara 4, Uday Raj 5 (Assistant Professor in Department of Electrical Engineering GIET Kota2) (Department of Electrical
More informationA Fifteen Level Cascade H-Bridge Multilevel Inverter Fed Induction Motor Drive with Open End Stator Winding
A Fifteen Level Cascade H-Bridge Multilevel Inverter Fed Induction Motor Drive with Open End Stator Winding E. Chidam Meenakchi Devi 1, S. Mohamed Yousuf 2, S. Sumesh Kumar 3 P.G Scholar, Sri Subramanya
More informationHVDC High Voltage Direct Current
HVDC High Voltage Direct Current Typical HVDC Station BACK TO BACK CONVERTER STATION MONO POLAR WITH GROUND RETURN PA Back to Back Converters indicates that the Rectifiers & Inverters are located in the
More informationECET Industrial Motor Control. Variable Frequency Drives. Electronic Motor Drives
ECET 4530 Industrial Motor Control Variable Frequency Drives Electronic Motor Drives Electronic motor drives are devices that control the speed, torque and/or rotational direction of electric motors. Electronic
More information(12) Patent Application Publication (10) Pub. No.: US 2005/ A1
(19) United States (12) Patent Application Publication (10) Pub. No.: Su US 2005O127853A1 (43) Pub. Date: Jun. 16, 2005 (54) (76) (21) (22) (51) MULTI-LEVEL DC BUS INVERTER FOR PROVIDING SNUSODAL AND PWM
More informationModern Concepts of Energy Control Technology through VVVF Propulsion Drive
Modern Concepts of Energy Control Technology through VVVF Propulsion Drive Satoru OZAKI, Fuji Electric Systems Co., Ltd. Ken-ichi URUGA, Toyo Denki Seizo K.K. Dr. D.P. Bhatt, Autometers Alliance Ltd ABSTRACT
More informationPower Electronics Converters for Variable Speed Pump Storage
International Journal of Power Electronics and Drive System (IJPEDS) Vol. 3, No. 1, March 2013, pp. 74~82 ISSN: 2088-8694 74 Power Electronics Converters for Variable Speed Pump Storage Othman Hassan Abdalla,
More informationIt is the engineer ideality to have logos of chasing perfect and professional spirit to design Industrial products. Ending of chasing is ambition and
It is the engineer ideality to have logos of chasing perfect and professional spirit to design Industrial products. Ending of chasing is ambition and mental embodiment assume condition that the pure perfect
More informationAFC Series. 0.5kVA to 2000kVA. Manual AC Power Source THE POWER TEST EXPERTS.
AFC Series 0.5kVA to 2000kVA Manual AC Power Source THE POWER TEST EXPERTS AFC Series 0.5kVA to 2000kVA Product Overview The is a complete line of single and three phase AC power sources. With Power levels
More informationMATLAB Implementation of a Various Topologies of Multilevel Inverter with Improved THD
2016 IJSRSET Volume 2 Issue 3 Print ISSN : 2395-1990 Online ISSN : 2394-4099 Themed Section: Engineering and Technology MATLAB Implementation of a Various Topologies of Multilevel Inverter with Improved
More informationP2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company
P2 Power Solutions Pvt. Ltd. An ISO 9001:2008 Company Quality Power within your Reach P2 Power Magnetics P2 Power Solutions Pvt. Ltd. P2 Power Solutions Pvt. Ltd. provides EMC and power quality solutions,
More informationCrossover Switches Cell (CSC): A New Multilevel Inverter Topology with Maximum Voltage Levels and Minimum DC Sources
Crossover Switches Cell (CSC): A New Multilevel Inverter Topology with Maximum Voltage Levels and Minimum DC Sources Hani Vahedi, Kamal Al-Haddad, Youssef Ounejjar, Khaled Addoweesh GREPCI, Ecole de Technologie
More informationMultilevel Technology with ALSPA VDM6000
Multilevel Technology with ALSPA VDM6 A World Leading Converter Topology Multilevel converters have created considerable interest in industrial applications, particulary in drives. Today, several successful
More informationMultilevel Inverter Based Statcom For Power System Load Balancing System
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE) e-issn: 2278-2834,p- ISSN: 2278-8735 PP 36-43 www.iosrjournals.org Multilevel Inverter Based Statcom For Power System Load Balancing
More informationFigure 1 Typical Inverter Block Diagram
AC Drives and Soft Starter Application Guide Walter J Lukitsch PE, Gary Woltersdorf Jeff Theisen, John Streicher Allen-Bradley Company Milwaukee, WI Abstract: There are usually several choices for starting
More informationMultilevel inverter with cuk converter for grid connected solar PV system
I J C T A, 9(5), 2016, pp. 215-221 International Science Press Multilevel inverter with cuk converter for grid connected solar PV system S. Dellibabu 1 and R. Rajathy 2 ABSTRACT A Multilevel Inverter with
More informationLow Order Harmonic Reduction of Three Phase Multilevel Inverter
Journal of Scientific & Industrial Research Vol. 73, March 014, pp. 168-17 Low Order Harmonic Reduction of Three Phase Multilevel Inverter A. Maheswari 1 and I. Gnanambal 1 Department of EEE, K.S.R College
More informationPowerFlex Medium Voltage Drives with Direct-to-Drive Technology Eliminating the Isolation Transformer
PowerFlex Medium Voltage Drives with Direct-to-Drive Technology Eliminating the Isolation Transformer Transformerless drives help industry reduce the cost of motor control while using standard motors.
More informationJoe Warner, Electric Power Industry Conference (EPIC), November 15, 2016 Advances in Grid Equipment Transmission Shunt Compensation
Joe Warner, Electric Power Industry Conference (EPIC), November 15, 2016 Advances in Grid Equipment Transmission Shunt Compensation Slide 1 Excerpt from the BoA BoA: Book of Acronyms MSC/MSR: Mechanically
More informationShattock, Nicholas (2014) High frequency-link cycloconverters for medium voltage grid connection. PhD thesis, University of Nottingham.
Shattock, Nicholas (4) High frequency-link cycloconverters for medium voltage grid connection. PhD thesis, University of Nottingham. Access from the University of Nottingham repository: http://eprints.nottingham.ac.uk/45//index.pdf
More informationMMC Design Aspects and Applications. John Strauss Siemens AG.
MMC Design Aspects and Applications John Strauss Siemens AG. John.Strauss@Siemens.com 1 VSC-HVDC with MMC Basic Scheme Reference HVDC PLUS Converter Arm Converter Module Power Module Electronics (PME)
More informationCompany Profile. Skype: carrie.rong Mob/Whatsapp: Web:
1 Email: carrie@sandi.cc Skype: carrie.rong Mob/Whatsapp: +86-13175696608 Web: www.lgis.cc Company Profile Yueqing Sandi Electric Co., Ltd specialized in the new energy source and electrical source scientific
More informationp. 1 p. 6 p. 22 p. 46 p. 58
Comparing power factor and displacement power factor corrections based on IEEE Std. 18-2002 Harmonic problems produced from the use of adjustable speed drives in industrial plants : case study Theory for
More informationECEN 613. Rectifier & Inverter Circuits
Module-10a Rectifier & Inverter Circuits Professor: Textbook: Dr. P. Enjeti with Michael T. Daniel Rm. 024, WEB Email: enjeti@tamu.edu michael.t.daniel@tamu.edu Power Electronics Converters, Applications
More informationOnsite Mobile AC High Voltage Test System
TSGMF(T) series Onsite Mobile AC High Voltage Test System Onsite mobile AC high voltage test systems are used for withstand voltage testing, partial discharge measurement, tan delta measurement to instrument
More informationPractical Experience with Differential Protection for Converter Transformers
315 Study Committee B5 Colloquium August 25-31, 213 Belo Horizonte, Brazil Practical Experience with Differential Protection for Converter Transformers Z. Gajić* ABB SA Products Sweden Summary The paper
More informationReducing Total Harmonic Distortion with Variable Frequency Drives
Reducing Total Harmonic Distortion with Variable Frequency Drives Low Harmonic Technology in Optidrive Eco Overview Overview Both AC line chokes and DC link chokes have historically been used with Variable
More informationPhD Dissertation Defense Presentation
PhD Dissertation Defense Presentation Wednesday, September 11th, 2013 9:30am 11:00am C103 Engineering Research Complex THEORETICAL ANALYSIS AND REDUCTION TECHNIQUES OF DC CAPACITOR RIPPLES AND REQUIREMENTS
More informationMatrix Technology for next generation Variable Speed Electric Motor Control
Matrix Technology for next generation Variable Speed Electric Motor Control First.Why do we need variable speed control of electric motors? Soft starting of electric motor Multiple starts and stops without
More informationA Novel H Bridge based Active inductor as DC link Reactor for ASD Systems
A Novel H Bridge based Active inductor as DC link Reactor for ASD Systems K Siva Shankar, J SambasivaRao Abstract- Power converters for mobile devices and consumer electronics have become extremely lightweight
More informationAn Interleaved Flyback Inverter for Residential Photovoltaic Applications
An Interleaved Flyback Inverter for Residential Photovoltaic Applications Bunyamin Tamyurek and Bilgehan Kirimer ESKISEHIR OSMANGAZI UNIVERSITY Electrical and Electronics Engineering Department Eskisehir,
More informationNew Multi Level Inverter with LSPWM Technique G. Sai Baba 1 G. Durga Prasad 2. P. Ram Prasad 3
New Multi Level Inverter with LSPWM Technique G. Sai Baba 1 G. Durga Prasad 2. P. Ram Prasad 3 1,2,3 Department of Electrical & Electronics Engineering, Swarnandhra College of Engg & Technology, West Godavari
More informationDiode Clamped Multilevel Inverter Using PWM Technology
Diode Clamped Multilevel Inverter Using PWM Technology Kokare Renuka rajendra Electronics and telecommunication dept. G.H.R.C.E.M. Ahmednagar, Maharashtra, India Abstract- Multilevel power conversion is
More informationNPTEL
NPTEL Syllabus Pulse width Modulation for Power Electronic Converters - Video course COURSE OUTLINE Converter topologies for AC/DC and DC/AC power conversion, overview of applications of voltage source
More informationAPF technical features. APF technical principle. About. solution is adaptive for load increasing in power grid
About Beijing PONOVO POWER ADVANCED TECH.CO.,LTD is the high tech enterprise which specialize in technology development for power uality control and management, professional in developing and popularizing
More informationMultilevel Inverters (Copyrighted Material) Prasad Enjeti, Ph.D.
Multilevel Inverters (Copyrighted Material) Prasad Enjeti, Ph.D. Associate Dean for Undergraduate Programs TI-Professor of Electrical & Computer Engineering Power Electronics & Power Quality Laboratory
More informationProgrammable Grid Simulator THE POWER TEST EXPERTS
PAS-F Series 45kVA to 1.6MVA Programmable Grid Simulator THE POWER TEST EXPERTS PAS-F Series 45kVA to 1.6MVA Product Overview The PAS-F Series is a broad line of programmable three phase output regenerative
More informationDistributed Energy Engineering
Distributed Energy Engineering (IKE1002) Part5: Frequency Converter Energy growth 2007-2030 by IEA World average Energy efficiency potential Electrical energy needed to produce 1 USD in GNP Midle-East
More informationSepic Topology Based High Step-Up Step down Soft Switching Bidirectional DC-DC Converter for Energy Storage Applications
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 2320-3331, Volume 12, Issue 3 Ver. IV (May June 2017), PP 68-76 www.iosrjournals.org Sepic Topology Based High
More informationElectric Grid Modernization Enabled by SiC Device based Solid State Transformers and Innovations in Medium Frequency Magnetics
1/31 Electric Grid Modernization Enabled by SiC Device based Solid State Transformers and Innovations in Medium Frequency Magnetics Dr. Subhashish Bhattacharya Department of Electrical and Computer Engineering
More informationHarmonic Penetration Analyses for DC-Link Frequency Converter Drive Systems by Considering the Motor-Side Converter as an Ideal Current Generator
International Conference on Renewable Energies and Power Quality (ICREPQ 13) Bilbao (Spain), 20 th to 22 th March, 2013 exçxãtuäx XÇxÜzç tçw céãxü dâtä àç ]ÉâÜÇtÄ (RE&PQJ) ISSN 2172-038 X, No.11, March
More informationSubject: Drive isolation transformers. VFD definition: History the short version. February 2012
February 2012 Subject: Drive isolation transformers This paper is designed to provide BASIC information on the application of transformers designed to manage secondary loads comprised largely of alternating
More informationEast-South HVDC Interconnector II, India : in commercial operation since 2003
8006/0 5 HVDC / FACTS Highlights http://www.siemens.com/facts http://www.siemens.com/hvdc NEW! >>> Welcome to Siemens Highlights & Innovations in Transmission and Distribution East-South HVDC Interconnector
More informationAC Drives and Soft Starter Application Guide
Feature AC Drives and Soft Starter Application Guide by Walter J Lukitsch PE, Gary Woltersdorf Jeff Theisen, and John Streicher Allen-Bradley Company Abstract: There are usually several choices for starting
More informationOperation of a Three-Phase PWM Rectifier/Inverter
Exercise 1 Operation of a Three-Phase PWM Rectifier/Inverter EXERCISE OBJECTIVE When you have completed this exercise, you will be familiar with the block diagram of the three-phase PWM rectifier/inverter.
More informationUNIT-III STATOR SIDE CONTROLLED INDUCTION MOTOR DRIVE
UNIT-III STATOR SIDE CONTROLLED INDUCTION MOTOR DRIVE 3.1 STATOR VOLTAGE CONTROL The induction motor 'speed can be controlled by varying the stator voltage. This method of speed control is known as stator
More informationFixed Series Compensation
Fixed Series Compensation High-reliable turnkey services for fixed series compensation NR Electric Corporation The Fixed Series Compensation (FSC) solution is composed of NR's PCS-9570 FSC control and
More informationTransformer-less PWM High Power Medium Voltage Variable Speed Drive
Transformer-less PWM Hi Power Medium Voltage Variable Speed Drive Emmanuel LELEU CONVERTEAM Parc d activités Techn hom 24 av. du Maréchal Juin 90008 BELFORT Cedex, France Tel.: +33 / (0) 384981215. Fax:
More informationELECTRONIC CONTROL OF A.C. MOTORS
CONTENTS C H A P T E R46 Learning Objectives es Classes of Electronic AC Drives Variable Frequency Speed Control of a SCIM Variable Voltage Speed Control of a SCIM Chopper Speed Control of a WRIM Electronic
More informationPeteris Spels, ABB Inc., WMEA, November 18, 2011 HARMONICS. ABB Group December 14, 2011 Slide 1
Peteris Spels, ABB Inc., WMEA, November 18, 2011 HARMONICS December 14, 2011 Slide 1 Agenda Harmonics: What they are? Where do they come from? Why bother? Regulations How to detect? How to avoid? Summary
More informationPower IT LV Active Filters PQFA - PQFL - PQFT
Power IT LV Active Filters PQFA - PQFL - PQFT The ABB comprehensive solution for active filtering of harmonics Pst Harmonics and Power Quality Harmonics caused by non-linear electrical loads such as variable
More informationG8000MM Series IGBT. 100 to 750 KVA UPS UNINTERRUPTIBLE POWER SYSTEMS. 94% Efficiency. Input PF >0.98 DESIGN
UNINTERRUPTIBLE POWER SYSTEMS PF >0.98 G8000MM Series 100 to 750 KVA UPS IGBT DESIGN 94% Efficiency Main Features State-of-the-Art Modular Design Provides Maximum Flexibility The Toshiba G8000MM Uninterruptible
More informationMMC (Modular Multilevel Converter)
MMC (Modular Multilevel Converter) Lisbon September 29 2017 Susana Apiñániz Smart Grids Energy and environment Division Tecnalia susana.apinaniz@tecnalia.com INDEX 1. General information 2. Power sub-modules
More informationTopology Simplification Method based on Switch Multiplexing Technique to Deliver DC-DC-AC Converters for Microgrids
Renewable Energy and ehicular Technology Lab Topology Simplification Method based on Switch Multiplexing Technique to Deliver -- Converters for Microgrids Wen Cai, Shanxu Duan, Fan Yi & Babak Fahimi HUST
More informationReliability Starts Here. PowerFlex TM 7000 Family of MV Drives
Reliability Starts Here. PowerFlex TM 7000 Family of MV Drives PowerFlex TM 7000 Your success depends on it. Superior Evolution As products evolve and technology advances, our customers demand drives that
More informationAnalysis of Harmonic Distortion in Non-linear Loads
Analysis of Harmonic Distortion in Non-linear Loads Anne Ko Department of Electrical Power Engineering Mandalay Technological University, Mandalay, Myanmar.Phone:+95-09-2225761 anneko101082@gmail.com Wunna
More informationNew Approaches for Harmonic Reduction Using Cascaded H- Bridge and Level Modules
New Approaches for Harmonic Reduction Using Cascaded H- Bridge and Level Modules ABSTRACT Prof. P.K.Sankala AISSMS College of Engineering, Pune University/Pune, Maharashtra, India K.N.Nandargi AISSMS College
More information100kW Grid-tied PV Inverter
13 14 13 14 Gridtied PV Inverter The PS S100KT gridtied PV inverter is designed for flexible use in different types of commercial rooftops and unility. It features isolation output transformer, low loss
More informationPTTS series. Power Transformer Test System. Scope of Work:
PTTS series Power Transformer Test System components insure the customer years of reliable service from their transformer test system. 750kV Class Power Transformer Test Lab PTTS series power transformer
More informationSGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:
SGMF(T) series Onsite Mobile AC High Voltage Test System On-site AC high voltage test systems are used for voltage withstanding test, partial discharge measurement, tan delta measurement on those instrument
More informationVSC Transmission. Presentation Overview. CIGRE B4 HVDC and Power Electronics HVDC Colloquium, Oslo, April LCC HVDC Transmission
CIGRE B4 HVDC and Power Electronics HVDC Colloquium, Oslo, April 2006 VSC Transmission presented by Dr Bjarne R Andersen, Andersen Power Electronic Solutions Ltd Presentation Overview - Basic Characteristics
More informationMicrowave Generator Technology for the 21 st Century Microwave Heating & Processing of Materials Seminar. Paul Burleigh. Overview
Microwave Generator Technology for the 21 st Century Microwave Heating & Processing of Materials Seminar Paul Burleigh Overview History Applications Generation technology Need for improvement New markets
More informationSimulation Analysis of SPWM Variable Frequency Speed Based on Simulink
Sensors & Transducers 2014 by IFSA Publishing, S. L. http://www.sensorsportal.com Simulation Analysis of SPWM Variable Frequency Speed Based on Simulink Min-Yan DI Hebei Normal University, Shijiazhuang
More informationA NOVEL SWITCHING PATTERN OF CASCADED MULTILEVEL INVERTERS FED BLDC DRIVE USING DIFFERENT MODULATION SCHEMES
International Journal of Electrical and Electronics Engineering Research (IJEEER) ISSN(P): 2250-155X; ISSN(E): 2278-943X Vol. 3, Issue 5, Dec 2013, 243-252 TJPRC Pvt. Ltd. A NOVEL SWITCHING PATTERN OF
More informationTechnical Paper. Harmonic Distortion in Data Centers
Technical Paper Harmonic in Data Centers Written By: Ian Wallace Summary Power quality and power reliability are critical to data center operation. As strides have been made to improve energy efficiency
More informationSpeed control of Induction Motor drive using five level Multilevel inverter
Speed control of Induction Motor drive using five level Multilevel inverter Siddayya hiremath 1, Dr. Basavaraj Amarapur 2 [1,2] Dept of Electrical & Electronics Engg,Poojya Doddappa Appa college of Engg,
More informationPower Factor improved by Variable Speed AC Drives By Mauri Peltola, ABB Oy, Drives
For your business and technology editors Power Factor improved by Variable Speed AC Drives By Mauri Peltola, ABB Oy, Drives The use of AC induction motors is essential for industry and utilities. AC induction
More informationVariable Frequency AC Source
Variable Frequency AC Source Functional Requirements List and Performance Specifications Students: Kevin Lemke Matthew Pasternak Advisor: Steven D. Gutschlag Date: November 15, 2013 1 Introduction: Variable
More informationAPQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)
APQline Active Harmonic Filters N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI 53051 P. (262) 754-3883 F. (262) 754-3993 www.apqpower.com Power electronic equipment and AC-DC power conversion equipment contribute
More informationREGENERATIVE GRID SIMULATOR MODEL SERIES MODEL SERIES PRELIMINARY. Regenerative Grid Simulator. Key Features :
PRELIMINARY MODEL 61800 SERIES Key Features : REGENERATIVE GRID SIMULATOR MODEL 61800 SERIES Market demand for Distributed Resource (DR) The 61800 grid simulator could also meet test products such as PV
More informationM.Tech in Industrial Electronics, SJCE, Mysore, 2 Associate Professor, Dept. of ECE, SJCE, Mysore
Implementation of Five Level Buck Converter for High Voltage Application Manu.N.R 1, V.Nattarasu 2 1 M.Tech in Industrial Electronics, SJCE, Mysore, 2 Associate Professor, Dept. of ECE, SJCE, Mysore Abstract-
More information