EX SSB 70 EX SSB 150 Protective cabinet system heating SSB
|
|
- Aron Gregory
- 5 years ago
- Views:
Transcription
1 ERICHR I C H O T T EX SSB 70 EX SSB 150 Protective cabinet system heating SSB Identification Planned certification from an order quantity of 25pc,. EC- type examination certificate Ambient temperature range Heat capacity max. Total Nominal current Nominal voltage II 2G Ex d e mb IIC T3 ZELM 09 ATEX xxx -20 C to +40 C 890 W (Type B) 700 W (Type A) 7 A max. Limiter T3 112 C Maintaining temperature Degree of protection 230 V, 48 to 62 Hz 5 C to +40 C IP 65 (Protective cabinet) Enclosure: Protective cabinet 70 L Protective cabinet 150 L Components: Radiator models EX HKA 33/ 100 AT Voltage controller Heat conductor connector Heating cable variants EX HKA 20/ 100 AT EX TRS /... AT EX GHL-ALAT 1600 Ω/km mineral isolated 1000 Ω/km mineral isolated Protective cabinet heating system The protective cabinet heating system consists of a series connection of voltage controller of the type TRS.../..AT and one combination of heating elements of the type HKA.../100 AT and a heat conductor loop. The heating is intended for the installation in protective cabinets of min. 70 L, especially 70 L and 150 L are available as standard. The system also includes the heated supply lines for the armatures in the protective cabinet. The viewing of the heat conductor loop comprehends both, its thermal behaviour inside as well as outside of the protective cabinet. The max. heat capacity in the protective cabinets amounts about 388 W. Outside approx. 18 W maximum are available per meter heating cable. The heating construction is suitable vor the use in zone 1 for gases up to group IIC and has a maximum surface temperature according to temperature class T3. Devices and protective systems for the intended use in potentially explosive areas according to guideline 94/9/EG Fa. Erich Ott Elektronische Geräte D Wiesbaden Rüdigerstrasse 15 Telephone Telefax mail erichott@gmx.de web
2 Protective cabinet system heating Ex SSB TABLE OF CONTENTS 1.0 Area of application System components Technical data Technical data protective cabinet Technical data of the installed part heating element EX HKA../100 AT in protective cabinet 150L SS Functional principle Wiring diagram Production number Type code Installation instructions Mounting possiblity standard Mounting possibility heating element horizontal Mounting possibility voltage controller at the bottom left Mounting possibility heating element vertical frontal Measuring point system Atmospheric layer measurement... 9 Warning The installation, configuration and commissioning may only be carried out by qualified and accordingly trained persons. The indications in this operating manual as well as the on-site installation and safety regulations must be observed. Proviso We reserve the right for technical changes. Aberrations, changes and printing errors do not justify any claims for damage. For safety components and systems the relevant standards and regulations must be observed as well as the according operating and installation instructions. Installation instructions The safety relevant data of the electrical circuits to be connected must accord with the technical data or rather the determinations of the EC-type examination certificate. For the installation / operation the EN EN ff, EN and EN and the respectively applicable installation regulations as well as the generally recognized rules of technique and this operating manual are relevant Only at compliance with this and the appropriate standards the EC-declaration of conformity is valid. Before the device is taken into operation, the installation must be checked without the device. An interchange of connections can lead to immediate destruction of the device. If any difficulties should occur during the installation, please do not manipulate the device improperly, because in this case the guarantee and the validity of the EC-type examination certificate void. Please contact us. In the case of service the device must be sent back to us. Maintenance The control mode of the Ex TRS / AT must be checked in reasonable intervals, minimum once a year. If the limiter of the HKA was triggered, the cause for the disturbance must be identified and rectified, before a reactivation can be made. The series current in the circuit should be measured and checked for the adherance to the max. values, as described in the technical data. Repair Repairs may only be carried out by the manufacturer. Changes that alter the designe of the device lead to immediate expiration of the certificate and any warranty claim voids. Read through this operating manual carefully, before you take the device into operation. Keep this manual at a place accessible for all users at any time. Please support us to improve this operating manual. We are grateful for your suggestions! Please contact us for technical queries! TELEPHONE: +49 (0) TELEFAX: +49 (0) erichott@gmx.de 1
3 E R I C H OTTT T 1.0 AREA OF APPLICATION Characteristics System cabinet for protective cabinet heating No internal Ex-viewing necessary anymore Flexible heating cable length adaption by means of variable voltage control One component less necessary than at comparable protective systems because of series connection The protective cabinet heating systems of the type Ex SSB70 and Ex SSB150 are used for the heating of installations and piping systens in zone 1 and higher. Typical is the heating of stubs of a temperature critical media current, which can be led to a display device or an analysing device into a protective cabinet to be heated. To cover the heating demand of both, fluid supply and instrument installation at inadmissible low ambient temperatures, the protective cabinet heating system is used. The ususal heating functions are frost protection or the holding of a min. admissible temperatore of up to +40 C. This consists of a series connection of voltage controller with controllable or fix holding temperature (TR / AT) heating element with controller and limiter function (HKA../100 AT) and a heat conductor loop, which is connected by use of a connection fitting of the type Ex GHL-ALAT. Because of the series connection it is secured, that a switch or limiter function affects on the complete heating circuit. For heating cable lengths of approx. 19m the combination of HKA 33/100 AT and mineral isolated heat conductors with a specific resistance of 1600 Ω/km (Type A) is recommended. For heat conductor lengths from 17 m to 29 m the combination of HKA 20/100 AT and mineral isolated heating cables with a specific resistance of 1000 Ω/km (Type B) is recommended. To provide the used components according to your specifications, the voltage controller is uses as variable voltage source. The max. admissible values to be adjusted must be chosen according to the used components. The necessary indications concerning this can be found in this operating manual. The typical application pertains to frost protection or the holding of a setpoint temperature of up to max. +40 C. The safety-related view also includes typical installations of the mineral isolated heating cable outside the protective cabinet. This runs in the outdoor area under a maximal 40 mm thick mineral isolation, paralles to cables made of rust resistant stainless steel or other metals. The function of the protective cabinet is to make a thermal separation of the ambient temperature and the objects to be heated possible. Similarly this helps to protect the installation from atmospheric influences. The protective cabinet is specified, due to its demands like thermal and electrostatic conductance, ambient temperature range and dimensions. 2.0 SYSTEM COMPONENTS 1. Protective cabinet 150 L 2. Protective cabinet 70 L 3. Electrical resistance heating cable (1600 Ω/km oder 1000 Ω/km) 4. Connection fitting type Ex GHL-ALAT 5. Heating element Ex HKA 33/100 AT or Ex HKA 20/100 AT 6. Voltage controller Ex TRS /...AT 3.0 TECHNICAL DATA Temperatures Ambient temperature range -20 C to +40 C Fluid temperature +60 C +40 C maximal typical Electrical data Capacity HKA../100 AT 370 W (Type A and B) Capacity heating cable 18,0 W/m (Type A and B) Total maximum capacity 700 W (Type A) 890 W (Type B) Series current 3,35 A 4,25 A Series fuse < 7 A Technical data Heating cable length at max. heating cable capacity 10 to 18,5 m 11 to 29,5 m 0,6 m Heating cable type Stub diameter min. 10 mm Temperature class Gas group Ignition protection category Stub wall thickness Insulation strength Thermal conductivity isolation T3 IIC Identification (Type A) (Type B) (Type A) (Type B) intern Mineral isolated coaxial transmission line approx. 1,2 mm 40 mm 0,04 W/mK 0344 II 2G Ex d e mb IIC T3 2
4 Protective cabinet system heating Ex SSB 3.1 TECHNICAL DATA PROTECTIVE CABINET Data 150 L cabinet Volume 150 L Height 750 mm Width 520 mm Depth 430 mm Thermal resistance 2,3 K/W Design windowless, antistatic Data 70 L cabinet Volume 70 L Height 640 mm Width 440 mm Depth 340 mm Thermal resistance 1,7 W/K Design windowless, antistatic 3.2 TECHNICAL DATA OF THE INSTALLED PART HEATING ELEMENT EX HKA../100AT IN PROTECTIVE CABINET 150 L Capacity of th Ex HKA /... AT in the protective cabinet 150L ss at an ambient temperature of -25 C. Interior temperature 10 C 20 C 30 C 40 C Necessary capacity 120 W 150 W 185 W 225 W Max. power drain of the Ex HKA (leakages) 380 W 330 W 280 W 240 W Reserve capacity determines the heat-up time 68% 54% 34% 6% 4.0 FUNCTIONAL PRINCIPLE 4.1 POSSIBLE WIRING DIAGRAM The protective cabinet heating of the type Ex SSB70/150 consists of a series connection of Ex TRS /... AT, Ex HKA../100AT and the connection fitting GH-ALAT or rather. GHL-ALAT, which is operated with a mineral isolated heating conductor loop. The connection is made exemplary according to the following diagram. For the connection of the respective connection cable in the potentially explosive atmosphere an accordingly suitable (if necessry certified) terminal box including cable gland must be used.. Main switch Conditioning cabinet TRSC GH HKA N Phase L1 33 Ω PE L1 N GH with heat conductor HKA 33/ 100 AT Intern = 3,4 A Heating loop Load bn bl bn bl Terminal box Voltage control with triac for Imax Heating loop R =... Ohm HKA 33/100 AT Intern = 3,4 A bn Controller gegn gegn Option controller without limiter TRSC T υ or sw sw Option controller with limiter TRSB 5.0 PRODUCTION NUMBER N bl bl Controller and limiter PE gegn bn Phase L1 xxxx / Year Month Serial number 3
5 E R I C H OTTT T 5.1 TYPE CODE 6.0 INSTALLATION INSTRUCTIONS Ex SSB The installation instructions of the individual components must be observed. You will find these in the respective operating manual. To fulfil the manifestations and technical data in each operating manual, attention should be paid the following notes: L protective cabinet L protective cabinet 1 2 Ex TRSC 210/ 5-70A AT With thermal fuse and temperature adjustment Ex TRSC 210/..A AT With therma fuse and fix temperature between 5-70 C. Please indicate fix temperature in C 3 - EX GHL-ALAT Standard version (see operating manual) 4 5 A B x m x m Ex HKA20/100 AT (for 1600 Ω/km) Ex HKA33/100 AT (for 1000 Ω/km) 1000 Ω/km Mi - cable heating cable length in m 1600 Ω/km Mi - cable heating cable length in m Please order the individual components analog to the desired construction and indicate the designated use of the component. The lengths of the respective connection cables are 1,2 m and they are made of silicone. If desired, also PTFE-connection cables are available, both variants alternatively available with protective hose. Example: 150L protective cabinet with TRSC fix adjusted voltage and variable temperature adjustment. Heat conductor sleeve GHL in standard version (also see operating manual GHL). Radiator HKA33/100AT Ω/km MI heating cable and 18 m heating cable length: Ex SSB _ B The mounting of the radiator and the rest of the installation must be carried out in accordance with the diagrams chapter The heat conductor sleeve must always be installed below the radiator, see diagram chapter Limit the maximum heating cable length in the cabinet to approx. 0,6m. If mounted horizontally the through heating in the cabinet is most regular. For this variant the GHL-ALAT is necessary. Do not lay heat conductor loops horizontally in loops, as then the thermal heats cumulate. Do not lay the heating cables on top of each other but always seperately. Lay heating cables in the protective cabinet without isolation. The indications on max. insulation strength and temperature of the medium in the pipelines to be heated must be complied with. The Ex GHL-ALAT must be self-assembled according to the enclosed operating manual. The connection fitting must always be installaed below the radiator with a lateral minimum distance of 3,5 cm, see picture 6.1. The circuit shall be secured with max. 7 A. The set temperature at the Ex TRS /... AT may not exceed +40 C. The series current must be adusted to o max. 3,35 A (Ex HKA33/100AT), or rather o max. 4,25 A (Ex HKA20/100AT) o For this purpose the voltage controller must be set on 100 V before putting into operation. The minimum value of 70 V should be used only cautiously, as the used potentiometer does not tolerate higher controlling torques (max. 0,5 Ncm). Rev up the voltage at the potentiometer so far until the max. permissible current is reached. The connection of the free conductor ends must be carried out in a suitable, also certified terminal box. Note: If the heating needs is lower than the according values, also other cable lengths can be installed. For the combination 2 at 40m heat conductor length still approx. 255 W heat capacity in the protective cabinet and 12,2 W/m at the heating cables are available. The indicated nominal current can, at longer heat conductor lengths than indicated, not be reached. In this case the max. ouput voltage must be adjusted at 4
6 09:43:03 09:51:38 10:00:12 10:08:46 10:17:21 10:25:55 10:34:29 10:43:04 10:51:38 11:00:12 11:08:47 11:17:21 11:25:56 11:34:30 11:43:04 11:51:39 12:00:13 12:08:48 12:17:22 12:25:57 12:34:31 12:43:05 12:51:40 13:00:14 13:08:48 13:17:23 13:25:57 13:34:31 13:43:06 13:51:40 14:00:14 14:08:49 14:17:23 14:25:57 14:34:32 14:43:06 14:51:40 15:00:15 15:08:49 15:17:23 15:25:58 15:34:32 15:43:06 15:51:41 16:00:15 16:08:49 16:17:24 16:25:58 16:34:32 Protective cabinet system heating Ex SSB the voltage controller. 6.1 MOUNTING POSSIBILITY STANDARD TEMPERATURE CURVE 100,00 Fühler Raum 90,00 Fühler E1 80,00 Fühler E2 70,00, Fühler E3 60,00 Fühler 5 50,00 Sensor 1 40,00 Sensor 2 30,00 Sensor 3 20,00 Sensor 4 10,00 Sensor 7, 0,00 Sensor 6 Analysis 75L cabinet TRSC- standard / HKA standard 5 TRSCAnalysis
7 ERICH O TT MOUNTING POSSIBLITY HEATING ELEMENT HORIZONTAL 6.2 TEMPERATURE CURVE 80 C Sensor R Sensor E1 70 C 60 C Sensor e2 Sensor e3 Sensor 1 50 C Sensor 2 40 C 30 C Sensor 3 Sensor 4 Sensor 5 20 C Sensor 6 10 C 0 C Sensor 7 16:31:27 16:22:52 16:14:18 16:05:44 15:57:09 15:48:35 15:40:01 15:31:26 15:22:52 15:14:17 15:05:43 14:57:09 14:48:34 14:40:00 14:31:26 14:22:51 14:14:17 14:05:42 13:57:08 13:48:34 13:39:59 13:31:25 13:22:51 13:14:16 13:05:42 12:57:07 12:48:33 12:39:59 12:31:24 12:22:50 12:14:16 12:05:41 11:57:07 11:48:32 11:39:58 11:31:24 11:22:49 11:14:15 11:05:41 10:57:06 10:48:32 10:39:57 10:31:23 10:22:49 10:14:14 10:05:40 09:57:06 09:48:31 09:39:57 Analysis 75L cabinet TRSC- standard / HKA horizontal installation 6 TRSCCurrent monitoring
8 6.3 08:50:41 08:57:20 09:03:58 09:10:37 09:17:15 09:23:54 09:30:32 09:37:11 09:43:49 09:50:27 09:57:06 10:03:44 10:10:23 10:17:01 10:23:40 10:30:18 10:36:57 10:43:35 10:50:14 10:56:53 11:03:31 11:10:09 11:16:48 11:23:26 11:30:05 11:36:43 11:43:22 11:50:00 11:56:39 12:03:17 12:09:56 12:16:34 12:23:13 12:29:51 12:36:30 12:43:08 12:49:47 12:56:25 13:03:04 13:09:42 13:16:20 13:22:59 13:29:37 13:36:16 13:42:55 13:49:33 13:56:11 14:02:50 14:09:28 14:16:07 14:22:45 Schutzkasten Systembeheizung Ex SSB MOUNTING POSSIBLITY VOLTAGE CONTROLLER AT THE BOTTOM LEFT TEMPERATURE CURVE 90 C Sensor room 80 C Sensor E1 70 C Sensor E2 60 C Sensor E3 50 C Sensor 1 40 C Sensor 2 Sensor 3 30 C Sensor 4 20 C Sensor 7 10 C Sensor 6 0 C Sensor 5 Analysis 75L cabinet TRS-C at the bottom left HKA standard 7 TRS-C monitoring
9 ERICH O TT 6.4 MOUNTING POSSIBLITY HEATING ELEMENT VERTICAL FRONTAL TEMPERATURE CURVE 90 C Sensor room Sensor E1 80 C Sensor E2 70 C Sensr e3 60 C Sensor 1 Sensor 2 50 C Sensor 3 40 C Sensor 4 30 C Sensor 5 20 C Sensor 6 Sensor 7 10 C Time[min] 7,2 14,6 22,0 29,3 36,7 44,1 51,4 58,8 66,2 73,5 80,9 88,3 95,6 103,0 110,4 117,7 125,1 132,5 139,8 147,2 154,6 161,9 169,3 176,7 184,0 191,4 198,8 206,1 213,5 220,9 228,2 235,6 243,0 250,3 257,7 265,1 272,4 279,8 287,2 294,5 301,9 309,3 316,6 324,0 331,4 338,7 346,1 353,5 360,8 368,2 375,6 382,9 390,3 0 C Analysis 75 L cabinet TRS-C standard / HKA vertical frontal installation 8 TRS-C Current monitoring
10 Protective cabinet system heating Ex SSB 7.0 MEASURING POINT SYSTEM ATMOSPHERIC LAYER MEASUREMENT 110 C C C 50 C 30 C 10 C -10 C 08:49:10 08:58:21 09:07:33 09:16:44 09:25:55 09:35:07 09:44:18 09:53:30 10:02:41 10:11:52 10:21:04 10:30:15 10:39:27 10:48:38 10:57:49 11:07:01 11:16:12 11:25:24 11:34:35 11:43:46 11:52:58 12:02:09 12:11:21 12:20:32 12:29:44 12:38:55 12:48:06 12:57:18 13:06:29 13:15:41 13:24:52 13:34:03 13:43:15 13:52:26 14:01:38 14:10:49 14:20:00 14:29:12 14:38:23 14:47:35 14:56:46 15:05:57 15:15:09 15:24:20 15:33: Sensor E1 Sensor E2 Sensor E3 Sensor 1 Sensor 2 Sensor 3 Sensor 4 Sensor 5 Sensor 6 Sensor 7 Room temperatur Power frequency -30 C C
11 10 E R I C H OTTT T
12 ERICHR I C H O T T Elektronische Geräte Inh. Barica Ott D Wiesbaden Rüdigerstrasse 15 Telephone +49 (0) Telefax +49 (0) mail erichott@gmx.de web BA_Ex_SSB-02_e_121115
Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters
Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters ll 2G EEx ia llc T6 As our products are continuously improved, we reserve the right to make any change in the stated specifications
More informationLF Conductivity Measuring Probe
LF Conductivity Measuring Probe Contents 1 General 1.1 Introduction 1.2 Application range 2 Safety 2.1 Warnings and symbols 3 Transport and storage 4 Application 5 Measuring principle 6 Assembly 7 Construction
More informationInstallation & Operating Manual. iwap202
Installation & Operating Manual iwap202 This page is intentionally left blank. Document Number 409345 (based on 407655) (See Last Page for Revision Details) For warranty information, refer to Terms and
More informationResistance Thermometers Model Series TR7X0, Sheathed Design
Electrical Temperature Measurement Resistance Thermometers Model Series TR7X0, Sheathed Design WIKA Data Sheet TE 60.40 Applications T Suitable for all industrial and laboratory applications Special Features
More informationSET Installation and Operating Instructions. Level switch for two sensors
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 20.2.2013 Internet: www.labkotec.fi 1/14 SET-2000 Level switch for two sensors Copyright 2013 Labkotec
More informationMINI MCR-SL-UI-I-LP-NC
2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals.
More informationPressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751
060R9345 Instructions Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Content Page 1 Description/application 2 Identification 3 Specifications 4 Safety instructions 5 Installation/dimensions
More informationTRB - PS. Temperature controller - limiter - alarm unit. Labelling II (2) GD. Level functional safety SIL 1 EC-type examination certificate
ERICHR I C H O T T TRB - PS Temperature controller - limiter - alarm unit Labelling II (2) GD Level functional safety SIL 1 EC-type examination certificate BVS 07 ATEX F 001 2 Pt -0 inputs Three-wire-system
More informationM224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #
Solenoid coil MKY/18x60 For explosion-hazard zones Protection class IP65/66/67 Optional with integrated amplifier electronics Ex db IIC T6 / T4 Gb Ex tb IIIC IP65 T80 C/T130 C Db Ex db I Mb II 2 G Ex db
More informationIntrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751
Data sheet Intrinsically safe pressure transmitter MBS 420, MBS 425, MBS 470 and MBS 475 The intrinsically safe pressure transmitter program is designed for use in hazardous environments and offers a reliable
More informationKFS. Flap-type flow meter. Design and range of application
Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is
More informationInductive sensor slot-type SI2-K08-AP7
SI2-K08-AP7 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments 3-wire DC, 10 30 VDC NO contact, PNP output Cable connection Wiring diagram Type
More informationDesign and applications
Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated
More informationOperating Manual. isolate501
Operating Manual isolate501 Document Number 413569 (See Last Page for Revision Details). Copyright Extronics Ltd, 2015 Page 2 of 21 Contents 1 Introduction... 4 2 Safety Information and Notes... 5 2.1
More informationMT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D
MT MOTORI ELETTRICI Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D TABLE OF CONTENTS 1. Introduction 2. Scope of application 3. Installation
More informationIntrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H
Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments WIKA Data Sheet PE 81.51 Applications
More informationInstallation and Operating Instructions for Phase Demodulator Type _.2
Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EU Low Voltage Directive 2014/35/EU and the Electromagnetic Compatibility (EMC)
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationSafety Manual. Omni-ID UHF Tags
Safety Manual Omni-ID UHF Tags This page is intentionally left blank. Document Number 330556 (See Last Page for Revision Details) 2012 Extronics Limited. This document is Copyright Extronics limited. Extronics
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationRAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL
RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL 1 Contents 1. Application... 5 2. meter set... 6 3. BASIC REQUIREMENTS, OPERATIONAL SAFETy... 6 4. installation... 10 4.1. Mounting... 10 4.2. External
More informationTransducer transmitter BILT 4 II 2(1) G. Technical Manual
GB Transducer transmitter BILT 4 II 2(1) G Technical Manual Transducer transmitter BILT 4 Contents Introduction General... 3 Ex.safety description... 4 Technical data... 5 Installation General... 6 Mechanical
More informationMiniature resistance thermometer Explosion-protected version Model TR34, thread-mounted
Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction
More informationVTM Local Display Unit with Frequency and Analogue Output
Küppers Elektromechanik GmbH Flow Meters Liebigstr. 2 D-85757 Karlsfeld Phone +49 81 31/59 39 10 Fax + 49 81 31/9 26 04 VTM Local Display Unit with Frequency and Analogue Output The VTM is a programmable
More informationInstallation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN
Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas Mimablad: 176GB/1999-10-25 Ersätter: MG-1000-EEx USAGE MG-1000-EEx is suitable for use in measurement
More informationRudder or propeller angular position transmitter KINAX WT720
Description The is a robust, absolute angular position transmitter, which is particularly suitable for use in marine applications such as the detection of rudder or propeller positions. In contrast to
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationAC/DC Current Oscilloscope Probe Model SL261
AC/DC Current Oscilloscope Probe Model SL261 USER MANUAL I ZERO 100 mv/a 10 mv/a OFF Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated
More informationIntrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i
Intrinsically Safe Compact Controller CTR 210i Intrinsically Safe Bargraph Indicator BGI 210i DMT 02 ATEX E 148 2. Supplement also grahics display Revision 4 IBS BatchControl GmbH Im Sträßchen 2 4 Tel.:
More informationBrunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2
Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 UK-QB101575 / 29.05.2012 Brunata a/s is a Danish owned company. We have more than 90 years of experience within developing and producing
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) STExS1 & STExS2 Sounder For use in Flammable Gas and Dust Atmospheres 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT POTENTIAL ELECTROSTATIC CHARGING
More informationLocal control stations for Zone 1 and Zone 21. Features. Description
Local control stations for Zone and Zone Local control stations for Zone and Zone Features The right size/material enclosure Optimum functionality thanks to the great variety of components Customised planning
More informationIntroduction. Additional Information. Temperature transmitter for HART protocol. Suitable for all standard requirements. Measurement made easy
ABB MEASUREMENT & ANALYTICS COMMISSIONING INSTRUCTION TTF200 Field-mount temperature transmitter Temperature transmitter for HART protocol. Suitable for all standard requirements Measurement made easy
More informationDescription of equipment
Applicant: Electrical Apparatus: KROHNE Messtechnik GmbH & Co. KG Level Radar BM 70M-Ex Description of equipment The Types BM 70M-Ex Level Radar gauges serve to continuously measure the product level in
More informationOperating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information
*09005137* BA_EN_DE50 Rev.A 11/12 *09005137* d e v e l o p i n g s o l u t i o n s DE50 Operating Manual Differential pressure transmitter Table of Contents 1 Safety guidelines 2 Application purpose 3
More informationUser manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD
User manual Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD Contents Precautions Intended use General 1 Specification 3
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationSITRANS T measuring instruments for temperature
Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.
More informationIntrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F
Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F,
More informationOperator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique
Operator Manual Transmitters Series KAT-... Analog transmitters in 2-wire technique Important Safety Notes! In the case of non-observance of the installation and safety notes or improper use of the transmitter
More informationExpert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters
Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters Class l, Division 1 Group A-D IIC T4 As our products are continuously improved, we reserve the right to make any change in the stated
More informationMANUAL HYDROBAR. Manufactured by: Fax: H/US/Hydrobar/ /00 Klay Instruments Page 1
MANUAL HYDROBAR WARNING Before installing the Hydrobar, read the warnings and advisements on the last page for personal and system safety, and for optimum performance, make sure you thoroughly understand
More informationSolexy USA, LLC International Blvd Cincinnati, Ohio Phone: Fax:
OVERVIEW The Solexy RX series explosion proof and intrinsically safe antenna coupler is an integrated protection device that facilitates non-ex certified radio antenna installation in hazardous areas.
More informationPRetrans Table of contents
HART TRANSPARENT REPEATER PRetrans 5106 Table of contents Warnings 16 Safety instructions 17 EC Declaration of Conformity 19 How to demount SYSTEM 5000 20 Application 21 Technical characteristics 21 Mounting
More informationOPTITEMP TT 10 C/R Technical Datasheet
OPTITEMP TT 10 C/R Technical Datasheet Analogue 2-wire temperature transmitter Temperature linear 4...20 ma output Rangeable with solder pads and potentiometers Easy wiring through large center hole The
More informationICARUS ELECTRONIC GAS VOLUME CONVERTER
ICARUS ELECTRONIC GAS VOLUME CONVERTER 1. INTRODUCTION 2. TECHNICAL DETAILS ICARUS is an electronic volume converter which, combined with a gas meter, provides the gas measurement in Sm3, calculated at
More informationUser manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD
User manual Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD Contents Precautions Intended use General 1 Specification 3
More informationInstallation and Operational Instructions for ROBA -switch Type 017._00.2
OBA -switch Type 017._00.2 Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EC Low Voltage Directive 2014/35/ EC and the EMC Directive
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationKINAX WT 717 Programmable Transmitter for Angular Position
Ruggedized version Application The KINAX WT 717 (Fig. 1) converts the angular position of a shaft into a load-independent direct current signal, proportional to the angular position. The unit is contact
More informationElectrical Temperature Measurement
Electrical Temperature Measurement Resistance Thermometers Model TR10-B, for Additional Thermowell Applications Machinery, plant and tank construction Energy and power plant technology Chemical industry
More informationMid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL
Mid-West Instrument BULLETIN NO. ELEC-IM140/11A Replaces ELEC-IM140-141/09A ELECTRICAL Gauges with switches have one or two SPST or SPDT hermetically sealed adjustable set point reed switch assemblies.
More informationSubmersible pressure sensor For water and wastewater Model LW-1
Replacement product: Model LF-1 Level measurement Submersible pressure sensor For water and wastewater Model LW-1 WIKA data sheet LM 40.03 Applications Level measurement in rivers and lakes Deep well and
More informationMINI-PS AC/2X15DC/1
MII-PS-100-240AC/2X15DC/1 Power supply unit ITERFACE Data sheet 100299_en_04 1 Description PHOEIX COTACT - 2010-10-20 Features MII POWER is the extremely slim power supply unit with constructional widths
More informationOperating instructions Fail-safe delay timer AZS About this document. Content
8 Appendix 8.1 Wiring example...4 8.2 Integral System Diagnostics (ISD)....5 9 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / 11.2017 / v.a. - 101126753-
More informationIsolators A3/1.
Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration
More information2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
SAFE INSTALLATION MANUAL (FM APPROVAL) -WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe/explosion-proof) MODEL B6U/B6U-B BEFORE USE... SAFETY PRECAUTIONS This manual describes
More informationIsolating Spark Gaps. Isolating spark gaps at an additional earth ring conductor. Isolating spark gaps for Ex zones
Isolating Spark Gaps Isolating spark gaps at an additional earth ring conductor Isolating spark gaps for Ex zones 187 Protective Spark Gaps For use at roof supports for overhead lines For indirect connection
More informationWind Transmitter compact xx
THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021075/08/11 Wind Transmitter compact 4.3519.xx.140... 961 ADOLF THIES GmbH & Co. KG Hauptstraße 76
More informationSection 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5
LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section 2, Calibration Calculations... 7 Calibration Procedure... 8 Section
More informationChecklist for electromechanical and electronic active energy meters in accordance with the MID Directive (2004/22/EC)
Checklist for electromechanical and electronic active energy meters in accordance with the MID Directive (2004/22/EC) Applicant: Instrument type: 1. General requirements NOTE: Definitions are based on
More informationIndustrial Automation HIMatrix System. Manual H 7033
Industrial Automation HIMatrix System Manual H 7033 Three-Wire Transmitter Supply HIMA Paul Hildebrandt GmbH + Co KG Industrial Automation HI 800 417 BEA Important Notes All HIMA products mentioned in
More informationConnection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition
Converter Connection 1-channel EEx ia IIC for 4-wire and 6-wire bridges Analogue output 0/4 ma... 20 ma or 4mA...-12mA Full bridge load cells and strain gauges circuit for resistance bridges up to 17 Ω
More informationBinary Output without Power Supply Series 9176
Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationMINI-PS AC/24DC/1.3
Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics
More informationCapacitive level meters CLM 40 INSTRUCTIONS MANUAL. průmyslová elektronika
průmyslová elektronika INSTRUCTIONS MANUAL Capacitive level meters CLM 40 Before level meters usage please read instructions in this service manual and keep it for further use. Service manual is for all
More informationiant200 iant212 iant213 iant214 iant215 iant216 iant217 iant218 iant219 iant220 iant221 iant222 Operating Manual iant2xx Series of Antennas
iant200 iant212 iant213 iant214 iant215 iant216 iant217 iant218 iant219 iant220 iant221 iant222 Operating Manual iant2xx Series of Antennas This page is intentionally left blank. Document Number 403449
More informationCable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*
Features Assembly Cable gland series for shielded EMC cables Brass nickel-plated or stainless steel AISI 316 Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex d, Ex e and Ex tb Metric and NPT
More informationOPTIWAVE 7300 C Supplementary instructions
OPTIWAVE 7300 C Supplementary instructions Radar (FMCW) Level Transmitter for agitated liquids in process applications Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE 7300 C General
More informationMANUAL HYDROBAR. Manufactured by: 7991 CZ DWINGELOO 7990 AA DWINGELOO The Netherlands
MANUAL HYDROBAR WARNING Before installing the HYDROBAR, read the warnings and advisements on page 9 for personal and system safety, and for optimum performance, make sure you thoroughly understand the
More informationOEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted
Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant
More informationTarget disk flowmeter for liquids and gases
Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight
More informationOperating Instructions
Level and Pressure Operating Instructions VEGATOR 620, 621, 622 max. 0 10 min. 0 10 on VEGATOR 622! 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 Note Ex area... 2 1 Product description
More informationGETTING STARTED GUIDE NI AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous
GETTING STARTED GUIDE NI 9239 4 AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous This document explains how to connect to the NI 9239. Note Before you begin, complete the software and hardware installation procedures
More informationUser and Safety Manual ProLine P224xx P1
The Art of Measuring. User and Safety Manual ProLine P224xx P1 English 17 Loop-Powered Isolators/Splitters www.knick-international.com Contents 17 Safety Information 18 Short Description 19 Intended Use
More informationBAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description
BAR--N-N-EX Antenna barrier for the hazardous area Data sheet 060_en_00 PHOENIX CONTACT 05-06-0 Description Using an antenna barrier, you can execute HF outputs of wireless modules with intrinsic safety.
More informationIndustrial Automation HIMatrix System. Manual H 7032
Industrial Automation HIMatrix System Manual H 7032 Two-Wire Transmitter Supply HIMA Paul Hildebrandt GmbH + Co KG Industrial Automation HI 800 415 BEA Important Notes All HIMA products mentioned in this
More informationIsolators A3/1. Ex i Power Supply Field Circuit Ex i Series
> Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:
More informationINSTALLATION AND OPERATION MANUAL
Version 2.2 MS1016 MTF SERIES VIBRATING PROBES FOR LIQUIDS AND HYC-PKK-312 SWITCHING ISOLATOR INSTALLATION AND OPERATION MANUAL Hycontrol Limited, Larchwood House, Orchard Street, Redditch, Worcestershire,
More informationSingle-Channel Safety Barriers with Electronic Current Limitation Series 9004
Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due
More informationED701 General Industry Pressure Transmitter
ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationFloat Switches with Permanent Magnet For Vertical Installation Model RSM
Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring
More informationKMS-2 Exd Magnetostrictive Level Transmitter
Installation and Operating Instructions KMS-2 Exd Magnetostrictive Level Transmitter Revision F 20/09/2018 ATEX KMS-2 Ex d Transmitter Contents Symbols Used...1 Safety information...1 Introduction...2
More informationSubmersible pressure sensor For oils and fuels Model LF-1
Level measurement Submersible pressure sensor For oils and fuels Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems for oils and fuels Overfilling and dry-run
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More informationDISCRETE INPUT MODULE, 16 points
INSTRUCTION MANUAL DISCRETE INPUT MODULE, points (Modbus) RM-DA MODEL RM-DA BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.
More informationTSSP-1 (Stainless Steel Thermistor Probe) Manual Rev A
TSSP-1 (Stainless Steel Thermistor Probe) Manual 57-6028 Rev A This page intentionally left blank. 2 2014 Dyacon, Inc Contents NOTICES...4 Copyright 2014 Dyacon, Inc...4 Manufacturer...4 Declarations...5
More informationTechnical Data. General specifications. Rated operating distance s n 3 mm
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up
More informationTechnical Information Condumax CLS21D/CLS21
TI00085C/07/EN/14.14 71268310 Products Solutions Services Technical Information Condumax CLS21D/CLS21 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1.0 cm 1 Application
More informationGETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous
GETTING STARTED GUIDE NI 9228 8 AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous This document explains how to connect to the NI 9228. Note Before you begin, complete the software and hardware installation procedures
More informationProtection components
Multifunction protection relays LT-P Environment Conforming to standards IEC 947-4-1, IEC 34-11, IEC 755, VDE 010, VDE 00. &Ãmarking Meets the essential requirements of the Low Voltage equipment (LV) &
More information600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet
Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration
More informationTechnical Specification FLUXUS ADM 8127B
FLUXUS ADM 8127B Liquid Ultrasonic Flowmeter for Permanent Installation in Hazardous Areas in the Mining Environment FLUXUS ADM 8127B is especially designed for the stationary use in explosive atmosphere
More informationKINAX 2W2 Programmable Transmitter for Angular Position
Application The KINAX 2W2 (Figs. 2 and 3) converts the angular position of a shaft into a load independent direct current signal, proportional to the angular position. The unit is contact free and has
More informationTechnical Information Condumax CLS15D/CLS15
TI0009C/07/EN/4.4 7268306 Products Solutions Services Technical Information Condumax CLS5D/CLS5 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 0.0 cm or k = 0. cm Application
More informationInstallation and Operational Instructions for ROBA -multiswitch Type 019._00.2
Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EU Low Voltage Directive 2014/35/ EU and the Electromagnetic Compatibility (EMC)
More information06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500
Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched
More informationQUINT-PS/ 3AC/24DC/10
Primary-switched power supply with SFB technology, 3 AC, output current 10 A INTERFACE Data sheet 103131_en_01 1 Description PHOENIX CONTACT - 09/2009 Features QUINT POWER power supply units Maximum system
More informationE8EB-N0C2B E8EB-N0B2B
Slim Sensor Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree of protection
More information