SGS-CSTC Standards Technical Services. SGS-CSTC(Shanghai)Co.,Ltd EMC TEST REPORT SHEMO AV01-A2 LINCON AUTOMATION CO., LTD
|
|
- Crystal Stafford
- 5 years ago
- Views:
Transcription
1 No. 588 West Jindu Road, Songjiang District, Shanghai, China SGS-CSTC Standards Telephone: +86 (0) Fax: +86 (0) Application No.: Applicant: Equipment Under Test (EUT): EMC TEST REPORT SHEMO AV01-A2 LINCON AUTOMATION CO., LTD Page 1 of 40 NOTE: The following sample(s) submitted was/were identified on behalf of the client as EUT Name: LinCon HMI Model No.: LC104S, LC057S, LC080S, LC121S, LC150S, LC057SL, LC070SL, LC080SL, LC104SL Serial No.: Not supplied by client Standards: EN 55011: 2007/A2:2007 EN : 2005 EN : 2006+A1:2009+A2:2009 EN : 2008 Date of Receipt: Dec. 31, 2008 Date of Test: Jan. 08, 2009 to Jan. 12, 2009 Date of Issue: Dec. 29, 2011 Test Result : PASS The CE mark as shown below can be used, under the responsibility of the manufacturer, after completion of an EC Declaration of Conformity and compliance with all relevant EC Directives. Jim Xu E&E Section Head SGS-CSTC Liky Zhu E&E Project Engineer SGS-CSTC(Shanghai)Co.,Ltd Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company s findings at the time of its intervention only and within the limits of Client s instructions, if any. The Company s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to thesample(s) tested and such sample(s) are retained for 90 days only Member of the SGS Group (Société Générale de Surveillance)
2 2 Test Summary SGS-CSTC Standards Page: 2 of 43 Test Test Requirement Test Method Class / Severity Result Conducted Emission (150K to 30MHz) Radiated Emission (30MHz to 1000MHz) EN 55011: 2007/A2:2007 EN 55011: 2007/A2:2007 Class A PASS EN 55011: 2007/A2:2007 EN 55011: 2007/A2:2007 Class A PASS Harmonic Current Emission on AC, up to 2kHz EN : 2006+A1:2009+A2:2009 EN : 2006+A1:2009+A2:2009 Clause 7 of EN PASS Voltage Fluctuation and Flicker on AC EN : 2008 EN : 2008 ESD EN : 2005 IEC :2001 Radio-Rrequency Rlectromagnetic Field.,80MHz to 1 GHz,1.4GHz to 2 GHz,2GHz to 2.7 GHz Electrical Fast Transients (EFT) on AC EN : 2005 IEC : 2008 Clause 5 of EN Contact Air 10V/m 3V/m ±4 kv ±8 kv 1V/m 80%, 1kHz, AM EN : 2005 IEC :2004 ±2.0kV Surges on AC EN : 2005 IEC :2005 Injected Currents on AC, 150kHz to 80MHz Power-frequency magnetic field Voltage Dips and Interruptions on AC EN : 2005 IEC :2006 EN : 2005 IEC :2001 EN : 2005 IEC :2004 ±1.0kV D.M. ±2.0kV C.M. 10Vrms (emf), 80%, 1kHz Amp. Mod. 50,60 Hz 30A/m 0 % UT* for1per 40 % UT* for10per 70 % UT* for 25per 0 % UT* for 250per PASS PASS PASS PASS PASS PASS N/AΨ PASS
3 Page: 3 of 43 Remark: * U T is the nominal supply voltage. D.M. Differential Mode. C.M. Common Mode. Ψ N/A Not Applicable Note: 1.According to the validated standards, the models mentioned in the report SHEMO AV01-A1 issued by SGS-CSTC. So the models in this report are deemed to fulfil the EMC requirements without testing. 2.The Power-frequency magnetic field test will not apply to the quipment containing no Components susceptible to magnetic fields, such as Hall elements or magnetic field sensors, according to EN
4 3 Contents SGS-CSTC Standards Page: 4 of 43 1 COVER PAGE TEST SUMMARY CONTENTS GENERAL INFORMATION CLIENT INFORMATION GENERAL DESCRIPTION OF E.U.T DETAILS OF E.U.T DESCRIPTION OF SUPPORT UNITS STANDARDS APPLICABLE FOR TESTING DEVIATION FROM STANDARDS ABNORMALITIES FROM STANDARD CONDITIONS MONITORING OF EUT FOR ALL IMMUNITY TEST TEST LOCATION TEST FACILITY...ERROR! BOOKMARK NOT DEFINED. 5 EQUIPMENTS USED DURING TEST EMISSION TEST RESULTS CONDUCTED EMISSIONS MAINS TERMINALS, 150KHZ TO 30MHZ E.U.T. Operation Measurement Data RADIATED EMISSIONS (30MHZ TO 1GHZ) E.U.T. Operation Measurement Data HARMONICS TEST RESULTS Measurement Diagram and Data FLICKER TEST RESULT Test Results: IMMUNITY TEST RESULTS PERFORMANCE CRITERIA DESCRIPTION IN CLAUSE 4 OF EN : ESD E.U.T. Operation Direct Application Test Results RADIO FREQUENCY ELECTROMAGNETIC FIELDS TEST E.U.T. Operation Test Results ELECTRICAL FAST TRANSIENTS (EFT) E.U.T. Operation Test Results On AC Supply: SURGES E.U.T. Operation Test Results: Pass Page
5 Page: 5 of INJECTED CURRENTS 0.15MHZ TO 80MHZ E.U.T. Operation Test Results: VOLTAGE DIPS AND INTERRUPTIONS E.U.T. Operation Test Results: PHOTOGRAPHS CONDUCTED EMISSION TEST SETUP RADIATED EMISSION TEST SETUP HARMONIC&FLICKER TEST SETUP ESD TEST SETUP RADIO FREQUENCY ELECTROMAGNETIC FIELDS TEST SETUP SURGE/ VOLTAGE DIPS AND INTERRUPTIONS TEST SETUP EFT TEST SETUP INJECTED CURRENTS TEST SETUP EUT CONSTRUCTIONAL DETAILS... 36
6 Page: 6 of 43 4 General Information 4.1 Client Information Applicant: LINCON AUTOMATION CO., LTD Address of Applicant: RM2146, BUILDING E, OVERSEAS SCHOLAR BUSINESS PARK, EAST LAKE HIGH-TECH DEVELOPMENT ZONE, WUHAN, P.R.C Manufacturer: LINCON AUTOMATION CO., LTD Address of RM2146, BUILDING E, OVERSEAS SCHOLAR BUSINESS Manufacturer: PARK, EAST LAKE HIGH-TECH DEVELOPMENT ZONE, WUHAN, P.R.C 4.2 General Description of E.U.T. EUT Name: LinCon HMI Model No.: LC104S, LC057S, LC080S, LC121S, LC150S, LC057SL, LC070SL, LC080SL, LC104SL Brand Name Not supplied by client Serial No.: Not supplied by client 4.3 Details of E.U.T. Power Supply: AC230V Power Cord: About 1,5m 4.4 Description of Support Units Name / Function Model No. Remark N/A N/A N/A 4.5 Standards Applicable for Testing The customer requested EMC tests for LinCon HMI. The standards used were EN 55011: 2007/A2:2007, EN : 2005, EN : 2006+A1:2009+A2:2009 and EN : Table 1 : Tests Carried Out Under EN 55011: 2007/A2:2007 Standard EN 55011: 2007/A2:2007 Conducted Emission EN 55011: 2007/A2:2007 Radiated Emissions Indicates that the test is not applicable Indicates that the test is applicable Status
7 Page: 7 of 43 Table 2: Tests Carried Out Under EN : 2006+A1:2009+A2:2009 & EN : 2008 Standard EN : 2006+A1:2009+A2:2009 Harmonic Current Emission on AC EN : 2008 Voltage Fluctuation and Flicker on AC Indicates that the test is not applicable Indicates that the test is applicable Status Table 3: Tests carried out under EN : 2005 Standard IEC :2001 Electrostatic discharge test IEC : 2008 Radio frequency electromagnetic fields test Status IEC :2004 Electrical fast transients/burst test IEC :2005 Surges test IEC :2006 Injected Currents test IEC :2001 Power-frequency magnetic field immunity test IEC :2004 Voltage dips and interruptions test Indicates that the test is not applicable Indicates that the test is applicable Note The EUT does not contain any component which is susceptible from the magnetic field. 4.6 Deviation from Standards None. 4.7 Abnormalities from Standard Conditions None. 4.8 Monitoring of EUT for All Immunity Test Visual: 4.9 Test Location All tests were performed at:
8 SGS-CSTC Standards No.588 West Jindu Road, Songjiang District, Shanghai, China Tel: Fax: Page: 8 of Test Confident level The test facility is recognized, certified, or accredited by the following organizations: CNAS (No. CNAS L0599) CNAS has accredited SGS-CSTC Standards to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration Laboratories) for the competence in the field of testing. Date of expiry: FCC Registration No.: SGS-CSTC Standards has been registered and fully described in a report filed with the Federal Communications Commission (FCC). The acceptance letter from the FCC is maintained in our files. Registration No.: , Expiry Date: Industry Canada (IC) IC Assigned Code: 8617A The 3m Semi-anechoic chamber of SGS-CSTC Standards has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 8617A. Expiry Date: VCCI (Member No.: 3061) The 3m Semi-anechoic chamber and Shielded Room of SGS-CSTC Standards has been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: R-3172 and C-3514 respectively. Date of Registration: Date of Expiry: Measurement Uncertainty According to CISPR Test Item Frequency Range Measurement Uncertainty Conducted Emission 150KHz 30MHz 3.5dB Radiated Emission 30MHz 1000MHz 4.0dB Note: The measurement uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.
9 Page: 9 of 43 5 Equipments Used during Test Conducted Emission Item Test Equipment Manufacturer Model No. Serial No. Cal. Date Cal. Due date 1 EMI test receiver Rohde & Schwarz ESCS Line impedance stabilization network ETS 3816/ Radiated Emission Item Test Equipment Manufacturer Model No. Serial No. Cal. Date Cal. Due date 1 EMI test receiver Rohde & Schwarz ESU Antenna SCHWARZBECK VULB CONTROLLER INNCO CO / / Harmonic &Flicker Item Test Equipment Manufacturer Model No. Series No. Cal. Date Cal. Due date Single phase 1 harmonics&flicker EM test DPA500 V analyzer 2 AC SOURCE 6KVA EM test ACS500 V Electrostatic Discharge Test Item Test Equipment Manufacturer Model No. Series No. Cal. Date Cal. Due date 1 Electrostatic Discharge Simulator KIKUSUI KES4021 LL
10 Page: 10 of 43 Radio Frequency Electromagnetic Fields Test Item Test Equipment Manufacturer Model No. Serial No. Cal. Date Cal. Due date 1 Ultra broadband antenna Rohde & Schwarz HL amplifier AR 30W1000B amplifier AR 30S1G power meter Rohde & Schwarz NRP Single generator Rohde & Schwarz SMR EFT Test Item Test Equipment Manufacturer Model No. Series No. Cal. Date Cal. Due date 1 Ultra-compact simulator EM test UCS500M4 V Surge Test Item Test Equipment Manufacturer Model No. Series No. Cal. Date Cal. Due date 1 Ultra-compact simulator EM test UCS500M4 V Voltage dips and Interruption Test Item Test Equipment Manufacturer Model No. Series No. Cal. Date Cal. Due date 1 Ultra-compact simulator EM test UCS500M4 V Motorised Variac EM test MV2616 V Injected Currents Test Item Test Equipment Manufacturer Model No. Series No. Cal. Date Cal.Due date 1 AM/FM signal generator AEROFLEX 2023A / PAMP Conducted RF test system HAEFFLY PAMP
11 Page: 11 of 43 3 CDN impedance and K-factor LUTHI L-801 M2/M / / General Equipment Item Test Equipment Manufacturer Model No. Serial No. Cal. Date Cal.Due date 1 Atmosphere meter pressure Shanghai ZhongXuan Electronic Co;Ltd BY-2003P / CLAMP METER FLUKE Thermo-Hygrometer ZHICHEN ZC Digital meter illuminance TES electrical electronic Corp. TES-1330A
12 Page: 12 of 43 6 Emission Test Results 6.1 Conducted Emissions Mains Terminals, 150kHz to 30MHz Test Requirement: EN 55011: 2007/A2:2007 Test Method: EN 55011: 2007/A2:2007 Test Date: Jan. 08, 2009 Frequency Range: 150KHz to 30MHz Class / Severity: Class A Detector: Peak for pre-scan (9kHz Resolution Bandwidth for MHz) Quasi-Peak if maximised peak within 6dB of Quasi-Peak limit Operating Environment: E.U.T. Operation Temperature: 21.0 C Humidity: 48 % RH Atmospheric Pressure: 1006 mbar EUT Operation: Test the EUT with full function according to standard Measurement Data An initial pre-scan was performed on the live and neutral lines with peak detector. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission were detected.
13 Page: 13 of 43 L line Receiver Receiver Frequency QP Limit Margin AV Limit Margin Level Level (MHz) (dbuv) (dbuv) (db) (dbuv) (dbuv) (db) 0.15 * * * * 0.50 * * * * 1.00 * * * * 1.40 * * * * 2.00 * * * * 3.50 * * * * 6.00 * * * * * * * * * * * * * * * * * means the emission level is 6dB lower than the relevant limit.
14 Page: 14 of 43 N line Receiver Receiver Frequency QP Limit Margin AV Limit Margin Level Level (MHz) (dbuv) (dbuv) (db) (dbuv) (dbuv) (db) 0.15 * * * * 0.50 * * * * 1.00 * * * * 1.40 * * * * 2.00 * * * * 3.50 * * * * 6.00 * * * * * * * * * * * * * * * *
15 Page: 15 of 43 * means the emission level is 6dB lower than the relevant limit. 6.2 Radiated Emissions (30MHz to 1GHz) Test Requirement: EN 55011: 2007/A2:2007 Test Method: EN 55011: 2007/A2:2007 Test Date: Jan. 08, 2009 Frequency Range: 30MHz to 1GHz Measurement Distance: 3m Class / Severity: Class A Limit: 50.0 dbµv/m between 30MHz & 230MHz 57.0 dbµv/m between 230MHz & 1GHz Detector: Peak for pre-scan (120kHz resolution bandwidth)
16 Page: 16 of 43 Quasi-Peak if maximised peak within 6dB of limit E.U.T. Operation Operating Environment: Temperature: 26 C Humidity: 50 % RH Atmospheric Pressure: 1004 mbar EUT Operation: The EUT is in representative work mode Measurement Data An initial pre-scan was performed in peak detection mode. Quasi-Peak was performed at the frequencies with maximized peak emission were detected. Horizontal:
17 Page: 17 of 43 Final Result 1 Frequency (MHz) QuasiPeak (dbuv/m) Meas. Time (ms) Bandwidth (khz) Antenna height (cm) Polarity Turntable position (deg) Corr. (db) Margin (db) Limit (dbuv /m) H H H H H H
18 Vertical : SGS-CSTC Standards Page: 18 of 43 Final Result 1 Frequency (MHz) QuasiPeak (dbuv/m) Meas. Time (ms) Bandwidth (khz) Antenna height (cm) Polarity Turntable position (deg) Corr. (db) Margin (db) Limit (dbuv/m) V V V V V V
19 Page: 19 of Harmonics Test Results Test Requirement: Test Method: Frequency Range: Test Class: EN : 2006+A1:2009+A2:2009 EN : 2006+A1:2009+A2:2009 Up to 2kHz Class A Test Date Jan. 11, Measurement Diagram and Data Average harmonic current results Hn Ieff [A] Ieff [%] Limit [A] Result E E PASS E PASS E E-3 PASS E PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS
20 Page: 20 of E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS Maximum harmonic current results Hn Ieff [A] Ieff [%] Limit [A] Result E E PASS E PASS E E-3 PASS E PASS E E-3 PASS E PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS E E-3 PASS
21 Page: 21 of Flicker Test Result Test Requirement: EN : 2008 Test Method: EN : 2008 Test Date: Jan. 11, 2009 Class/Severity: Clause 5 of EN Measurement Time: 2h Detector: As per EN Test Results: Pass Maximum Flicker results EUT values Limit Result Pst PASS Plt PASS dc [%] PASS dmax [%] PASS dt [s] PASS
22 Page: 22 of 43 7 Immunity Test Results 7.1 Performance Criteria Description in Clause 4 of EN :2005 Performance Criterion A: Performance Criterion B: Performance Criterion C: The apparatus shall continue to operate as intended during and after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible loss of performance. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation, and from what the user may reasonably expect from the apparatus if used as intended. The apparatus shall continue to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. No change of actual operating state or stored data is allowed. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation, and from what the user may reasonably expect from the apparatus if used as intended. Temporary loss of function is allowed, provided the function is self-recoverable or can berestored by the operation of the controls. 7.2 ESD Test Requirement: EN : 2005 Test Method: IEC :2001 Test Date: Jan. 12, 2009 Discharge Impedance: 330 Ω / 150 pf Discharge Voltage: Air Discharge: ±8 kv Polarity: Number of Discharge: Discharge Mode: Discharge Period: E.U.T. Operation Operating Environment: Contact Discharge: HCP: VCP: Positive & Negative ±4 kv ±4 kv ±4 kv Minimum 10 times at each test point for Contact and VCP Discharge;Minimum 10 times at each test point for Air Discharge Single Discharge 1 second minimum
23 Page: 23 of 43 Temperature: 23.0 C Humidity: 49 % RH Atmospheric Pressure: 1008 mbar EUT Operation: The EUT is in representative work mode Direct Application Test Results Observations: Test Point: 1. All insulated enclosure & seams around EUT. 2. All touchable metal material of EUT Direct Application Test Results Discharge Level (kv) Polarity (+/-) Test Points Contact Discharge Air Discharge 8 +/- 1 N/A A 4 +/- 2 A N/A Indirect Application Test Results Observations: Test Point: 1. All sides. Indirect Application Test Results Discharge Level (kv) Polarity (+/-) Test Point Horizontal Coupling Vertical Coupling 4 +/- 1 A A Results: A: No degradation in the performance of the EUT was observed. N/A: Not applicable (not required in the standard or floor moutned the EUT)
24 Page: 24 of Radio Frequency Electromagnetic Fields Test Test Requirement: EN : 2005 Test Method: IEC : 2008 Test Date: Jan. 12, 2009 Frequency Range: Test level: Modulation: Criteria: E.U.T. Operation 80MHz to 1GHz, 1.4GHz to 2GHz, 2GHz to 2.7GHz 80MHz to 1GHz,10V/m on enclosure 1.4GHz to 2GHz, 3V/m on enclosure 2GHz to 2.7GHz, 1V/m on enclosure 80%, 1kHz Amplitude Modulation Performance criteria A Operating Environment: Temperature: 23 C Humidity: 51 % RH Atmospheric Pressure: 1007 mbar EUT Operation: Test Results Pass The EUT is in representative work mode.
25 Page: 25 of Electrical Fast Transients (EFT) Test Requirement: EN : 2005 Test Method: IEC : 2004 Test Date: Jan. 12, 2009 Test Level: Polarity: Repetition Frequency: Burst Period: Test Duration: E.U.T. Operation ±2.0kV on AC Positive & Negative 5kHz 300ms 2 minute per level & polarity Operating Environment: Temperature: 21 C Humidity: 40 % RH Atmospheric Pressure: 1002 mbar EUT Operation: The EUT is in representative work mode Test Results On AC Supply: Lead under Test Level (±kv) Coupling Direct/Clamp L,N,PE ± 2.0 Direct A: No loss of function was observed. EUT operating mode On working mode Observations (Performance Criterion) (A)
26 Page: 26 of Surges Test Requirement: EN : 2005 Test Method: IEC :2005 Test Date: Jan. 12, 2009 Test Level: Polarity: Generator source impedance: Trigger Mode: ±1kV Line to Neutral, ±2kV Line to PE Positive & Negative 2Ω Line to Neutral, 12Ω Line to PE Internal No. of surges: 5 positive, 5 negative at 0, 90, 180, E.U.T. Operation Operating Environment: Temperature: 22.0 C Humidity: 50 % RH Atmospheric Pressure: 1017 mbar EUT Operation: The EUT is in representative work mode Test Results: Pass
27 Page: 27 of 43 Pulse No Line- Line Level (kv) Surge Interval Phase (deg) Observation (Performance Criterion) 1 5 L-N +1 60s 0 No loss of performance (A) 6 10 L-N -1 60s 0 (A) L-N +1 60s 90 (A) L-N -1 60s 90 (A) L-N +1 60s 180 (A) L-N -1 60s 180 (A) L-N +1 60s 270 (A) L-N -1 60s 270 (A) 1 5 L-PE +2 60s 0 (A) 6 10 L-PE -2 60s 0 (A) L-PE +2 60s 90 (A) L-PE -2 60s 90 (A) L-PE +2 60s 180 (A) L-PE -2 60s 180 (A) L-PE +2 60s 270 (A) L-PE -2 60s 270 (A) 1 5 N-PE +2 60s 0 (A) 6 10 N-PE -2 60s 0 (A) N-PE +2 60s 90 (A) N-PE -2 60s 90 (A) N-PE +2 60s 180 (A) N-PE -2 60s 180 (A) N-PE +2 60s 270 (A) N-PE -2 60s 270 (A)
28 Page: 28 of Injected Currents 0.15MHz to 80MHz Test Requirement: EN : 2005 Test Method: IEC :2006 Test Date: Jan. 12, 2009 Frequency Range: 0.15MHz to 80MHz Test level: 10V rms on AC Ports (unmodulated emf into 150 Ω) Modulation: E.U.T. Operation 80%, 1kHz Amplitude Modulation Operating Environment: Temperature: 22 C Humidity: 50 % RH Atmospheric Pressure: 1017 mbar EUT Operation: The EUT is in representative work mode Test Results: Frequency Line Test Level Modulation Step Size Dwell Time Observation (Performance Criterion) 150kHz to 80MHz 3 Wire AC Supply Cable 10Vrms 80%, 1kHz Amp. Mod. 1% 3S No Loss of Function (A)
29 Page: 29 of Voltage Dips and Interruptions Test Requirement: EN : 2005 Test Method: IEC :2004 Test Date: December 26, 2008 Test Level: No. of Dips / Interruptions: E.U.T. Operation 0% of U T (Supply Voltage) for 1 Periods 40% of U T (Supply Voltage) for 10 Periods 70 % of U T (Supply Voltage) for 25 Periods 0 % of U T (Supply Voltage) for 250 Periods 6 per Level Operating Environment: Temperature: 22 C Humidity: 50 % RH Atmospheric Pressure: 1017 mbar EUT Operation: Test the EUT with full function according to standard Test Results: EUT operating mode Dropout % U T Phase Duration of dropout in Periods No of dropout Time between dropout Observations (Performance Criterion) On mode s (A) On mode s (A) On mode s (A) On mode s (A) On mode s (B) On mode s (B) On mode s (B) On mode s (B) Performance C is within the acceptable criterion for Voltage Dips and Interruption test.
30 Page: 30 of 43
31 Page: 31 of 43 8 Photographs 8.1 Conducted Emission Test Setup 8.2 Radiated emission Test Setup
32 Page: 32 of Harmonic&Flicker Test Setup
33 Page: 33 of ESD Test Setup 8.5 Radio Frequency Electromagnetic Fields Test Setup
34 Page: 34 of Surge/ Voltage Dips And Interruptions Test Setup 8.7 EFT Test Setup
35 Page: 35 of Injected Currents Test Setup
36 Page: 36 of EUT Constructional Details
37 Page: 37 of 43
38 Page: 38 of 43
39 Page: 39 of 43
40 Page: 40 of 43
41 Page: 41 of 43
42 Page: 42 of 43
43 Page: 43 of 43 THE END OF REPORT
Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass
Reference No.: WTS15F0323845E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz Discontinuous Disturbance (Click) Radiated Emission,
More informationDiscontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz
Reference No.: WTN13F0706038E Page 2 of 40 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result
More informationEN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A
Reference No.: WT12106773-N-S-E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 150KHz to 30MHz Radiation Emission, 30MHz to 1000MHz EMISSION Test Standard Class / Severity Result
More informationEN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass
Reference No.: WTD15S0730643E Page 2 of 42 1 Test Summary Test Item Conducted Disturbance at Mains Terminal, 9kHz to 30MHz Radiation electromagnetic disturbance, 9kHz to 30MHz Radiation Emission, 30MHz
More informationDiscontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz
Reference No.: WTU15U0933879E Page 2 of 45 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result
More informationSGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.
588 West Jindu Road,Songjiang District,Shanghai,China Telephone: +86 (0) 21 6191 5666 Fax: +86 (0) 21 6191 5678 ee.shanghai@sgs.com Page: 1 of 23 1 Cover Page Application No.: Applicant: Manufacturer:
More informationTEST REPORT on behalf of Shanghai ZLAN Information Technology Co.,Ltd Serial Device Server
TEST REPORT on behalf of Shanghai ZLAN Information Technology Co.,Ltd Serial Device Server Prepared For: Shanghai ZLAN Information Technology Co.,Ltd. Room 1205, Building D Everbright Exhibition Center,
More informationPage: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003
Page: 1 of 20 EMC TEST REPORT Reference No. Applicant : WT05060412 : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Cable Standards Model No : UAS111-M, UAS111, UAS112 : EN55022:1998+A2:2003
More informationTEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25
15072259 001 Seite 2 von 25 Page 2 of 25 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE 4.1.4 DISCONTINUOUS INTERFERENCE
More informationEMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.
Report No.: UNI2016121702ER-01 Page 1 / 30 ShenZhen KY Technology Co.,Ltd EMC REPORT Prepared For: ShenZhen KY Technology Co.,Ltd Product Name: Smart bracelet No.369, BaoTian 1st RD, TieGang Industrial
More informationPage: 1 of 41 EMC TEST REPORT. Product Name : Multi-socket with surge protection : SPG3-B-10, SPG3-B-15, SPG3-B-5, SPG3-B-6
Page: 1 of 41 EMC TEST REPORT Reference No. Applicant : WT05060416 : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Multi-socket with surge protection Standards Model No. : SPG3-B-10,
More informationPage: 1 of 46 EMC TEST REPORT : SISF, SISF-2, SISFN-BLACK, SISFN-2-BLACK
Page: 1 of 46 Reference No. Applicant : WT05060414 EMC TEST REPORT : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Advanced surge protection Model No. : SISF, SISF-2, SISFN-BLACK,
More informationEMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758
Page 1 of 20 Report No. R011604553E EMC TEST REPORT for DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., LTD. Electronic calculator Model No.: KF15758 Prepared for Address Prepared by Address : DONGGUAN EVER
More informationTest Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:
Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator EAST ZTY-30KVA Date of Receipt : Aug. 30, 2013 Date of Test: Sep. 03, 2013
More informationTEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27
15072768 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE
More informationEMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B
Page 1 of 27 Report No. R011412016E-1 EMC TEST REPORT for LEDELS LIGHTING CO., LTD LED module Model No. : LL-F12T4815X6B Prepared for : LEDELS LIGHTING CO., LTD Address : 5F, Block C, Mingjinhai Ind. Park,
More informationEMC VERIFICATION SUMMARY Report No.: SZHH
EMC VERIFICATION SUMMARY Toy ITE Others Additional Models: 0801 to 0899 INCLUSIVE, 0804, 0804W, 0805, 0806, 0807, 0808, 0809, 0811, 0811W, 0812, 0813, 0814,0815, 0816, 0817,0817 ROOM 619, 6/F. PENINSULA
More informationRF Exposure Evaluation Report
588 West Jindu Road,Songjiang District,Shanghai,China Telephone: +86 (0) 21 6191 5666 Fax: +86 (0) 21 6191 5678 ee.shanghai@sgs.com Report No.: SHEM151100411103 Page: 1 of 8 1 Cover Page RF Exposure Evaluation
More informationCTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT
CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 EMC TEST REPORT TEST REPORT NUMBER : CGZ3150428-00472-E-R1 2/F., South Tower, Huoju Building, No.181, Canghai Road,
More informationShenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT
Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: +86-755-89486194 Fax: +86-755-89486194-805 TEST REPORT EN 55014-1 / EN 55014-2 Electromagnetic compatibility Requirements for household appliances,
More informationTEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated
Shenzhen CTL Testing Technology Co., Ltd. Tel: +86-755-89486194 Fax: +86-755-26636041 TEST REPORT EN 55014-1 / EN 55014-2 Electromagnetic compatibility Requirements for household appliances, electric tools
More informationPage: 1 of 44 EMC TEST REPORT. : Gembird Electronics Ltd. Room 1709, News Building, #2 Shennan Zhong Lu, Shenzhen, China
Page: 1 of 44 Reference No. Applicant EMC TEST REPORT : WT05121033 : Gembird Electronics Ltd. Room 1709, News Building, #2 Shennan Zhong Lu, Shenzhen, China Equipment Under Test (EUT) : Product Name :
More informationEMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.
DONGGUAN FIT-WATCH CO., LTD. EMC REPORT Prepared For : DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province Product Name : Trade Name : Model
More informationPrepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by
EMC TEST REPORT For KST DIGITAL TECHNOLOGY LIMITED Coreless Servo Model No.: X12-508 Additional Model No.: DS215MG, DS315MG, DS213MG, DS313MG, DS12C, DS12T, X12-306 Prepared for Address : KST DIGITAL TECHNOLOGY
More informationShenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20
Shenzhen Toby Technology Co., Ltd. Report No.: TB-EMC125641 Page: 1 of 20 EMC Test Report Application No. : TB12114299 Applicant : Newmb Technology Co., Ltd. Equipment Under Test (EUT) EUT Name : USB HUB
More informationEMC Test Report. Report Number: M030826
Page 1 of 36 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EMC Test Report Report
More informationTEST REPORT... 1 CONTENT...
CONTENT TEST REPORT... 1 CONTENT... 2 1 TEST RESULTS SUMMARY... 3 2 EMC RESULTS CONCLUSION... 4 3 LABORATORY MEASUREMENTS... 6 4 EMI TEST... 7 4.1 CONTINUOUS CONDUCTED DISTURBANCE VOLTAGE TEST... 7 4.2
More informationEMC test report AU01+E04
Customer: Altuflevskoye shosse,h.48,bld.1pr.1,room39 Moscow,127566 Russia EMC test report 130504-AU01+E04 This test report may not be copied or published in a part without the written authorization of
More informationEMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8
EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8 Prepared for Address : ShenZhen ZhangQing Electronic LTD :
More informationSGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
198 Kezhu Road, Scientech Park, Guangzhou Economic & Technological Development District, Guangzhou, China 510663 Telephone: +86 (0) 20 82155555 Fax: +86 (0) 20 82075059 Email: ee.guangzhou@sgs.com Page:
More informationEMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD
Page 1 of 45 Report No. R011607240E EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD INVERTER CHARGER Model No.: PV35-4K DC24V MPK, PV35-4K DC48V MPK, PV35-5K DC48V MPK, PV35-6K DC48V MPK Prepared
More informationTest Report GUANGDONG EAST POWER CO., LTD
Test Report Applicant: Product Name: Brand Name: Model No.: GUANGDONG EAST POWER CO., LTD Online High Frequency UPS EAST EA906IIRTS, EA906IIRTH Date of Receipt : Feb. 26, 2014 Date of Test: Mar. 24, 2014
More information2620 Modular Measurement and Control System
European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2620 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic
More informationCE-EMC Test Report. United GULF GATE Trd. Co. MS EN 55032:2015 EN :2014 EN :2013 EN :2010+A1 :2015 JQL E
CE-EMC Test Report Applicant: Product Description: Tested Model: Test Standards: Report No.: United GULF GATE Trd. Co. XonTel MS EN 55032:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 55024 :2010+A1 :2015
More informationITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA
Shenzhen BST Technology Co., Ltd. ITUNER NETWORKS CORPORATION EMC REPORT Prepared For : ITUNER NETWORKS CORPORATION 47801 Fremont Blvd. Fremont, CA. 94538 Product Name: PicoPSU-150 Trade Name: PicoPSU
More informationGuangdong East Power Co., Ltd. Uninterruptible Power Systems
Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Uninterruptible Power Systems EAST EA8806, EA8804 Date of Receipt : Nov. 01, 2012 Date of Test: Nov. 03, 2012
More informationCTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT
CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 EMC TEST REPORT TEST REPORT NUMBER : CNB3150602-00399-E 2/F., South Tower, Huoju Building, No.181, Canghai Road,
More informationTEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed
17035561 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 5.1.1 HARMONICS ON AC MAINS RESULT: Passed 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Passed 5.1.3 TERMINAL CONTINUOUS DISTURBANCE VOLTAGE AT RESULT:
More informationEMC Test report for LED Panel Light Models , , , , ,
4326247.50 EMC Test report for LED Panel Light Models 000529, 000530, 000531, 000532, 000535, 000536 Guangzhou, date of issue: 2016-02-24 Author:Jazz Liang By order of Marvo Verlichting B.V. at Hoogeveen,
More informationShenzhen Huanxi Technology Co., Ltd. Smart Self-balancing Scooter
EMC TEST REPORT For Shenzhen Huanxi Technology Co., Ltd Product Name: Smart Self-balancing Scooter Trademark: Model : Prepared For : Address: Prepared By : Address: N/A X1S6.5 X1L6.5, X1S 8, X1L8. Shenzhen
More informationEMISSION. EN : 2006 Clause 6.5 Pass. Harmonic Current EN : 2006+A1: 2009+A2: 2009 Class A Pass
Reference No.: WTS14S0513592E Page 2 of 44 1 Test Summary EMISSION Test Item Mains Terminal Disturbance Voltage, 150kHz to 30MHz Telecommunication ports interference voltage, 150KHz to 30MHz Radiation
More informationCE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10
CE/EMC TEST REPORT For HK QNOVATOR TECHNOLOGY CO.,LIMITED Product Name: Vacuum Tube Amplifier Trademark: Model Number: Prepared For: Address: Gemtune GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05,
More informationCENTRE OF TESTING SERVICE INTERNATIONAL
CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 FCC TEST REPORT TEST REPORT NUMBER : CGZ3150202-00097-E A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, Guangdong, China Report
More informationBy order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China
4317137.50 EMC Test report for LED Fixed luminaires Models LED12036-1R, LED12036-2TU, LED120363R, LED12036-4TU2, LED12036-6TR, LED12036-1R CHR, LED12036-2TU CHR, LED12036-3R CHR, LED12036-4TU2 CHR, LED12036-6TR
More informationEMC TEST REPORT For. Shenzhen Micsig Instruments Co., Ltd. Handheld Multifunctional Oscilloscope. Model No.: MS520S
EMC TEST REPORT For Shenzhen Micsig Instruments Co., Ltd. Handheld Multifunctional Oscilloscope Model No.: MS520S Additional Model No: Please Refer To Page 47 Prepared for Address : Shenzhen Micsig Instruments
More informationEMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009
Page 1 of 18 EMC TEST REPORT Report No.: TS08100063-EME Model No.: 33XR-A Issued Date: Jan. 08, 2009 Applicant: Test Method/ Standard: Test By: FLUKE CORP. 6920 Seaway Blvd, M/S 266D Everett, WA 98203
More informationEMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS
EMC-E20130903E EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS Prepared for : MPP SOLAR INC Address : 4F, NO. 50-1, SECTION 1, HSIN-SHENG S. RD. TAIPEI, TAIWAN Prepared by
More informationEMC TEST REPORT For TEA-Energy China Limited T8 LED Tube Model No.: T8-25W-150-ND-W-T00 Additional Model No: Please Refer To Page 58
EMC TEST REPORT For TEA-Energy China Limited T8 LED Tube Model No.: T8-25W-150-ND-W-T00 Additional Model No: Please Refer To Page 58 Prepared for : TEA-Energy China Limited Address : 0100029 Building,
More informationEMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China
EMC-Report No.:SZZCT1502030B-EMC-02 EMC Test Report Product Model Number : Drift car : P01 Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China
More informationTABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46
TABLE OF CONTENTS 1. GENERAL INFORMATION...5 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)...5 1.2 OBJECTIVE...5 1.3 RELATED SUBMITTAL(S)/GRANT(S)...5 1.4 TEST METHODOLOGY...5 1.5 TEST FACILITY...5
More informationTest Report. Apricus Solar Co., Ltd. Multi-Function Differential Controller
Test Report Applicant: Product Name: Brand Name: Model No.: Apricus Solar Co., Ltd. Multi-Function Differential Controller Apricus MFC-1 Date of Receipt : Jan. 04, 2012 Date of Test: Jan. 04, 2012 Date
More informationELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 1 / 35 TEST REPORT Responsible Party Manufacturer Description of Product Trade Name : Huan Vu Enterprise Co., Ltd. : Huan Vu Enterprise Co.,
More informationTABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT
ELECTROMAGNETIC COMPLIANCE TEST REPORT For Electric nail art drill Model Name: HBS-021, HBS-278, HBS-288, HBS-530, HBS-540 Brand Name: Date of Issue: May 7, 2011 Prepared For Houbos Hardware & Electrical
More informationEMC TEST REPORT For. Shenzhen Smar TEC Technology Company. Smart Charger For Li-Ion&Lifepo4 Battery Pack. Model No.:SPS-F12S02-021(42.
EMC TEST REPORT For Shenzhen Smar TEC Technology Company Smart Charger For Li-Ion&Lifepo4 Battery Pack Model No.:SPS-F12S02-021(42.6V/2A) Prepared for : Shenzhen Smar TEC Technology Company Address : 4-5/F.,
More informationFCC MPE REPORT. Equipment Under Test (EUT): NOTE: The following sample(s) submitted was/were identified on behalf of the client as
588 West Jindu Road, Xinqiao, Songjiang, 201612 Shanghai, China Telephone: +86 (0) 21 6191 5666 Fax: +86 (0) 21 6191 5678 ee.shanghai@sgs.com Page: 1 of 8 1 Cover Page FCC MPE REPORT Application No.: Applicant:
More informationTABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10
TABLE OF CONTENTS 1. General Description of EUT 3 2. General Information of Test 4-6 3.1 Conducted Emission Tests 7-10 3.2 Radiated Emission Tests 11-13 3.3 Radiated Electromagnetic disturbance Test 14-18
More informationTEST REPORT. Product: Thermo-Hygrometer Model No.: FL-201, FL-201W Trade mark: N/A Report No.: TCT151014E001 Issued Date: Oct. 15, 2015.
TEST REPORT Product: Thermo-Hygrometer Model No.: FL-201, FL-201W Trade mark: N/A Report No.: TCT151014E001 Issued Date: Oct. 15, 2015 Issued for: Shenzhen Flus Technology Co., Ltd 3rd Floor, Lantian Building,
More informationTest Report. Ningbo Goldmore Industrial Co.,Ltd.
Test Report Applicant: Ningbo Goldmore Industrial Co.,Ltd. Product Name: Brand Name: Model No.: LED CAMPING LANTERN with FAN N/A XJH-8098 Date of Receipt : Sep. 23, 2014 Date of Test: Sep. 25, 2014 Date
More informationEMC TEST REPORT : EGO-PZ001, EGO-PZ002, EGO-PZ003, EGO-PZ004, EGO-PZ005, EGO-PZ006, EGO-PZ007, EGO-PZ008
Report No. : 08.08.16.0259.01 EMC TEST REPORT Applicant : Eastgate Global Holding LTD Address : DongchuanRoad,Baiyun 1Street,No.6 Office 502 Manufacturer : Eastgate Global Holding LTD Address : DongchuanRoad,Baiyun
More informationBS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE
Page 1 of 18 Interference Testing And Consultancy Services (Pty) Ltd ITC SERVICES (PTY) LTD Reg 88/002032/07 Plot 44 Kameeldrift East, Pretoria Private Bag X13 Lynn East 0039 Republic of South Africa Tel
More informationTest Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49
Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49 The following information was submitted and identified by/on behalf of the client as: Applicant : Ningbo Shanhuang Electric Appliance
More informationEMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan
Page 1 of 32 EMC TEST REPORT Report No.: TS11020117-EME Model No.: NS-PSE, NS-POINTED, NS-PSQUARE, NS-PF-S, NS-PT, NS-PR, NS-PU, NS-PF-H, NS-BALIBA, NS-FLEXMA Issued Date: Mar. 01, 2011 Applicant: NORTE
More informationAPPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:
APPLICATION FOR EMC DIRECTIVE On Behalf of Shenzhen Qinhan Lighting Co., Ltd led flood light Trade Name: Model: QH-TGC-400W, QH-TGC-300W, QH-TGC-500W, QH-TGC-800W, QH-TGC-1000W Prepared For : Shenzhen
More informationEMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A
EMC Test Report Applicant: Address of Applicant: Trade Name: FATEK AUTOMATION CORP. 26FL, NO.29, SEC.2, JUNGJENG E. RD., DANSHUEI DIST., NEW TAIPEI CITY, TAIWAN, R.O.C. FATEK Equipment Under Test: Training
More informationEMC standards. Presented by: Karim Loukil & Kaïs Siala
Training Course on Conformity and Interoperability on Type Approval testing for Mobile Terminals, Homologation Procedures and Market Surveillance, Tunis-Tunisia, from 20 to 24 April 2015 EMC standards
More informationCertificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007
Certificate of Test WE HEREBY CERTIFY THAT: Certificate No.: R07122709E Yuan Hsun Electric Co., Ltd. No. 57, Chung He Rd, Zuo-Ying Dist., Kaohsiung City 813, Taiwan R.O.C. Quad photobeam detector Quad-200CS
More informationEMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45
REPORT NO. PRSZ15110502E EMC TEST REPORT For Boardcon Technology Limited. MINI9G45 Computer on Module Model No. : MINI9G45 Prepared For : Boardcon Technology Limited. : Room 702, Hua Feng Xin An Business
More informationSUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE
EMC TEST REPORT For SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD Product Name: Pure sine wave power inverter Trademark: Model : Prepared For : Address: Prepared By : Address: ML-1000W ML-300W---ML-8000W.
More informationEMC TEST REPORT. For PEAK ELECTRONIC(HUIZHOU)CO., LTD. DAB/FM radio Model No.: DB-318 Additional Model No.: DB-318B, DB-318C, DB-318R, DB-318U
EMC TEST REPORT For PEAK ELECTRONIC(HUIZHOU)CO., LTD. DAB/FM radio Model No.: DB-318 Additional Model No.: DB-318B, DB-318C, DB-318R, DB-318U Prepared for Address : PEAK ELECTRONIC(HUIZHOU)CO., LTD. :
More informationFCC TEST REPORT On Behalf of GZTOD.CO., LTD The Multifunctional Platooninsert Model No.: YA30WSL-6AU6U
FCC TEST REPORT On Behalf of GZTOD.CO., LTD The Multifunctional Platooninsert Model No.: YA30WSL-6AU6U Prepared for Address : GZTOD.CO., LTD : 2-5/F, Building A4, Huimingsheng Industrial Park, Tongfuyu
More informationEMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED. ITaste vv. Model No.: ITaste vv
EMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED ITaste vv Model No.: ITaste vv Prepared for : INNOKIN TECHNOLOGY CO., LIMITED Address : 3# Floor, #B Building, Heng Chang Rong Industrial Park, Gonghe
More informationEMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.
EMC Testing Report Equipment Under Test: Model Number: Serial No.: Applicant: Address of Applicant: Multi-Frequency (4 Channel Selectable) Twin Photobeam Detector Dual-120CS Dual-90CS, Dual-60CS, Dual-30CS
More informationCONFORMANCE TEST REPORT FOR EN /-6
CONFORMANCE TEST REPORT FOR EN 301489-1/-6 Client: Product: Model: Manufacturer/supplier: Aztech Systems Limited DECT Phone H315-S1 (FP) Aztech Systems Limited Date test item received: 2006/05/09 Date
More informationFCC REPORT. Dongguan Hele Electronics Co., Ltd. J11, J12, J13, Q7, Q28, Q26, Q29
FCC REPORT Applicant: Dongguan Hele Electronics Co., Ltd. Address of Applicant: Dalingya Industrial Zone, Daojiao Town, Dongguan City, Guangdong China Equipment Under Test (EUT) Product Name: Model No.:
More information1 SUMMARY OF STANDARDS AND RESULTS
1 SUMMARY OF STANDARDS AND RESULTS 1.1 Description of Standards and Results The EUT have been tested according to the applicable standards as referenced below: EMISSION Description of Test Item Standard
More informationFCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR
FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR Prepared for Address : SHENZHEN EAGLE TECHNOLOGY CO., LTD : A FIoor 1 BIdg.14, Changfeng
More informationEMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)
EMC TEST REPORT For Company Limited Liability «Faraday Electronics» Switching Mode Power Adaptor Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A) Prepared For : Company Limited Liability «Faraday
More informationEMC TEST REPORT For. Global Tech China Limited. 120/200 Watt Mightylite. Model No.: Additional Model No: Please Refer To Page 57
EMC TEST REPORT For Global Tech China Limited 120/200 Watt Mightylite Model No.: 0022031 Additional Model No: Please Refer To Page 57 Prepared for Address : Global Tech China Limited : 3 Flat A, Wai Yip
More informationEMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS
EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS Prepared For : Prepared By : Changzhou Airwheel Technology Co.,Ltd. Fl.5, East of No. 10 Building, high-tech
More informationTEST REPORT. Report No. : EM/2008/80003 Page : 1 of 54
Equipment Under Test Brand Name Model No. Added Model(s) Applicant Address of Applicant Page : 1 of 54 TEST REPORT : AC Servo Motor : Kingservo : AC 400W servo motor : N/A : Ho Fo Automation CO., LTD :
More informationEN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments
EMC Page 3 / 33 Test report No.: EN 61000-6-3:2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments Date of measurement: 2013-10-16
More informationEMC TEST REPORT For Prokits Industries Co., Ltd.
Page 1 of 34 EMC TEST REPORT For Prokits Industries Co., Ltd. Temperature-Controlled Soldering Station Model No.:SS-206/207 Series Test Report Number : ESTSZ110701228E EST COMPLIANCE LABORATORY LIMITED
More informationC E R T I F I C A T I O N
C E R T I F I C A T I O N Applicant Address Manufacturer Address : American Power Conversion Holding Inc. Taiwan Branch : 3F., No. 205, Sec. 3, Beixin Rd., Xindian Dist., New Taipei City 231, Taiwan R.O.C.
More informationAUSTRALIA TEST REPORT For. KLM Lighting Co., Limited. LED Down Light. Model No.: KLM-HP30WSN
AUSTRALIA TEST REPORT For KLM Lighting Co., Limited LED Down Light Model No.: KLM-HP30WSN Additional Model No.: KLM-SM-50-002, KLM-HP7WSS, KLM-HP10WSS, KLM-HP12WSS, KLM-HP15WSS, KLM-HP20WSS, KLM-HP30WSS,
More informationEMC TEST REPORT. : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan. Taiwan
EMC TEST REPORT For MPP SOLAR INC Model Number: PIP 2424MS Prepare for Address : MPP Solar Inc : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan Prepare by Address : MPP Solar In : 4F, No. 50-1,
More informationEMC TEST REPORT For Gztod. Co., Ltd. Smart USB Charger Model No.: YA50WS3-8U
EMC TEST REPORT For Gztod. Co., Ltd. Smart USB Charger Model No.: YA50WS3-8U Prepared for : Gztod. Co., Ltd. Address : 2-5/F, Building A4, Huimingsheng Industrial Park, Tongfuyu Dingfeng High-Tech District,
More informationEMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi
EMC TEST REPORT For Shenzhen Ruideou Keji Youxian Gongsi Product Name: Trademark: Milligram Scale WAOAW Model Number: W-01-50 Prepared For : Address: Prepared By : Address: Shenzhen Ruideou Keji Youxian
More informationA) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23
D I R E C T O R Y A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23 B) Test data: Immunity against Electrostatic discharge
More informationEMC TEST REPORT. according to
EMC TEST REPORT according to European Standard EN 55022:2006/A1:2007 Class B, EN 61000-3-2:2006, EN 61000-3-3:1995/A1:2001/A2:2006, EN 55024:1998/A1:2001/A2:2003 (IEC 61000-4-2:Edition 1.2:2001-04, IEC
More informationEN : 2006 Clause 6.5 Pass. Harmonic Current EN : 2006+A1: 2009+A2: 2009 Class A Pass
Reference No.: WTS14S0513590E Page 2 of 47 1 Test Summary Test Item Mains input Terminal Disturbance Voltage, 150kHz to 30MHz AC output Terminal Disturbance Voltage, 150kHz to 30MHz Radiation Emission,
More informationFCC TEST REPORT On Behalf of. Global Tech China Limited. Solar Light(Large)/28W,16W. Model No.: Additional Model No: Please Refer To Page 15
FCC TEST REPORT On Behalf of Global Tech China Limited Solar Light(Large)/28W,16W Model No.: 00013022 Additional Model No: Please Refer To Page 15 Prepared for : Global Tech China Limited Address : 3 Flat
More informationCTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT
CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 EMC TEST REPORT TEST REPORT NUMBER : CGZ3160623-01025-E-D 2/F., South Tower, Huoju Building, No.181, Canghai Road,
More informationTABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12
TABLE OF CONTENTS 1. General Description of EUT 3 2. General Information of Test 4-6 3.1 Conducted Emission Tests 7-12 3.2 Radiated Emission Tests 13-15 3.3 Radiated Electromagnetic disturbance Test 16-20
More informationCE EMC Test Certification
Certification No.: EC57C001 CE EMC Test Certification According to European Standard EN 55022:1998/A1:2000/A2:2003 Class A, EN 61000-3-2: 2000, EN 61000-3-3:1995/A1:2001 and EN 55024:1998/A1:2001/A2:2003
More informationTABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 11
Page : 2 / 38 TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST 4 3.1 CONDUCTED EMISSION TEST 7 3.2 RADIATED EMISSION TEST 11 3.3 ELECTROSTATIC DISCHARGE IMMUNITY TEST 14
More informationCENTRE OF TESTING SERVICE INTERNATIONAL
CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 FCC ID TEST REPORT TEST REPORT NUMBER : CGZ3160706-01168-EF TEST REPORT For FCC ID 47 CFR PART 15 OCT, 2015 Report Reference No....
More informationEMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter
Page 1 of 48 EMC TEST REPORT for Coliy Technology Co.,Ltd. Fluxgate Gaussmeter Prepared for : Coliy Technology Co.,Ltd. Address : Block B,9 th Floor,Xinzhongtai Business Building,Gushu 2nd Road,Xi Town,Bao
More informationRevision history. Revision Date of issue Test report No. Description KES-E Initial
Page (2) of (52) Revision history Revision Date of issue Test report No. Description - 02.06.2012 Initial Page (3) of (52) TABLE OF CONTENTS 1 General Information 4 2 Product Labelling Requirements 8 3
More informationTEST REPORT. In the configuration tested, the EUT complied with the standards specified above.
Page: 1 of 31 1 Cover Page TEST REPORT * Application No.: HKES130100000301 Applicant: 01 POWER LIMITED Product Description: USB Tray Hub Model No: 4372 Standards: EN 55022:2010, EN 55024:2010 Date of Receipt:
More informationTest Report GUANGDONG EAST POWER CO., LTD
Test Report Applicant: Product Name: Brand Name: Model No.: GUANGDONG EAST POWER CO., LTD Online High Frequency UPS EAST EA902IIRTS, EA902IIRTH Date of Receipt : Feb. 26, 2014 Date of Test: Mar. 24, 2014
More information