KF-510 Series Turbine Flow transducer user's manual

Size: px
Start display at page:

Download "KF-510 Series Turbine Flow transducer user's manual"

Transcription

1 TM KF-0 Series Turbine Flow transducer NINGBO KIO FLOW INSTRUMENTS CO.,LTD ISO

2 content. Digital paddlewheel meters. Range.External dimension. lectotype.installation requirements.terminal Description.)Terminal Description.)Electric current output.)pulse, frequency output.function of communication 7.Operations.)Panel construction and key definition.)function instructions.) construction.)detail parameter instructions.)detail instructions. Unit of flow. Instantaneous flow Resolution. Unit of total. Cumulative total flow resolution. Damping time(s)..7 Scale flow (m/h).8 Small flow termination%(low %).9 Frequency upper limit Hz.0 Liter/pulse(L/P). Cumulate Clear. Preset total positive P0 P0 P0 P0 P0 P0 P0 P0 P07 P07 P07 P08 P09 P0 P P P P P P P7 P8 P9 P0 P

3 . Digital paddlewheel meters series is as a speed flow metering,used to measure the full closure of pipeline and continuous flow of volume liquid.it is good for low viscosity liquids that can with high accuracy of instant and totalizer flow. Features: High accuracy digital paddlewheel technology Rate and total flow display Easy to operations and read,eight large digital LCD display Install quickly on existing pipe No pressure drop Corrosion resistant PVDF sensor Minimal maintenance required Long-life lithium battery Stopped-flow instructions Diversification installation Totalizer :can be reset and the permanent preservation User set security password Paddlewheel flow sensor Item paddlewheel flow sensor Velocity range 0.~m/s DN0-DN0 (with PVDF triplet) Diameter DN-00(insert type) Wetted material Sensor:PVDF Impeller:PVDF Shaft lever:ceramics Seal ring Viton,EPDM Working temperature PVDF: -0~ +0ºC Working pressure.0mpa, 0.8MPa Technical parameter Item Model Full scale accuracy Repeatability Temperature External dimension Installation method Power supply Output signal Communication Alarm Protection class Consumption Flow Convertor ±%,±.% ±0.% -0~ +ºC 00x00mm Panel mount compact type(dn0~dn0) DCV, battery power supply, AC0V ~0mA, Passive pulse RS8 Upper limit,lower limit,totalizer IP W Http: //

4 TM. Range Technical parameter DN(mm) Range (m³/h) Male 0 0.~.8 G/8 0.~ G/ 0 0.~ G/ 0.~ G 0.~ G½ Press (MPa) temp. (ºC).0 80ºC 0.8 A mm B mm G/8 G/ G½ ~0 G 8 7 A 0 B Insert type technical parameter DN(mm) Range (m/h) Press (MPa) temp. (ºC) Application Water treatment systems 0 ~0 ~0 80 8~ ~00 ~0 0 ~0 Counter-infiltration 00 0~00 Process flow monitor 0 80~800 Ultra-pure water delivery 00 00~000 Http: // Process treatment/ distribution Irrigation system Filtration system ºC Swimming pool and hot spring Groundwater packing Desalination and recycle Process cooling water

5 . External dimension 00mm 8mm 9 x 9mm 00mm. lectotype A: Compact Construction{ B: Remote Sensor Diameter Type of flow transmitter { AT: instantaneous delivery, flow totalizer AF: instantaneous delivery, flow totalizer,-0ma output signal AC: instantaneous delivery, flow totalizer,pulse output signal AD: instantaneous delivery, flow totalizer,rs8 {. L/S. L/min. L/h Flow unit. m³/s. m³/min. m³/h B:Battery power Power supply D: DCV { A B DN:0~0 AT AF AC AD B D 选型示例 - A AF B Http: //

6 . installation requirements Minimum straight pipe length requirements The digital paddlewheel meters accuracy is affected by disturbances such as pumps,elbows,tees,valves,etc.in the flow stream,install the meter in a straight run of pipe as far as possible from any disturbances.the distance required for accuracy will depend on the type of flange reducing 90 elbow xi.d. xi.d. xi.d. xi.d. 0xI.D. xi.d. x90 elbow division plane x90 elbow pump/valve xi.d. xi.d. 0xI.D. xi.d. 0xI.D. xi.d. Mounting location The digital paddlewheel meters is designed to withstand outdoor recommended vertical conditions.a cool,dry location,where the unit can be easilyl serviced is recommended.the meter can be mounted on horizontal or vertical runs of pipe.mounting at the vertical(twelve o clock)position on horizontal pipe is recommended.mounting anywhere around the diameter of vertical pipe is acceptable,however,the pipe must be completely full of water at all times.back pressure is essential on downward flows.see the minimum straight length of pipe requirement chart above.the meter can accurately o acceptable measure flow from either direction. Http: //

7 . Terminal Description back light switch + -0mA KHz - + RS DATA - Vo+ SIN+ SIN- + BAT - + -VDC - OFF AMP ON.)Terminal Description Items Label Function Instructions Remarks -0mA + -0mA - 0~KHz+ 0~KHz- RS8date+ RS8date - 7 Vo+ 8 SIN+ 9 SIN- -0mA Output positive terminal -0mA Output negative terminal Frequency/pulse output positive terminal Frequency/pulse output negative terminal RS8 Communication positiveterminal RS8 Communication negativeterminal Hall parts supply signal + signal -, Load resistance:70q (with link), Hart Communications external VDC power supply Active Output Mode The output amplitude of V load current <=0mA RS8 communication function (n just for transmitter has this function When the signal sensing element is a coil,connect signal + and signal (hop cap connect AMP and ON) when signal sensing element is Hall Parts,hop cap connect AMP and OFF 0 -V + -V - VDC Power, positive terminal VDC Power, negative terminal Power range: VDC -VDC BAT+ BAT- battery supply+ battery supply- When power is battery,we suggest pull out the hop cap of SW for extend battery service life. Http: //

8 .)Electric current output -0mA + -0mA - Receive Instruments The converter current output electrical isolation has been achieved. Output to take an active approach. Current output mode -0mA, 0mA current output value from the corresponding traffic parameter item "scale flow of value" is determined (reference to factory nameplate on the instrument measuring range a value). The maximum current output load resistance of 70Q, the load resistance includes the cables used to connect the resistance. Current output cable is recommended RWPx/0 PVC insulated sheathed cable shield...)pulse, frequency output VDC+(VDC+) KΩ(KΩ) 0~KHz+ 0~KHz- + - Counter VDC-(VDC-) The Transmitter frequency, pulse output has been achieved electrical isolation, the output for the active mode (see above chart). Transmitter frequency, pulse output with transistor output mode. Maximum pulse output frequency KHZ, the output pulse amplitude of V. Active mode the maximum load current 0mA, passive mode the maximum load current 0.A. As the frequency and pulse output terminals are shared, it is not to choice two output modes. Users can set the parameter "frequency output" to select the work. Frequency output upper limit corresponding to the measured flow value by the parameter item "scale flow value" decision (reference instruments to measure the scope of a factory nameplate values). Pulse output equivalent by the parameter 'pulse equivalent L / P "decision. Http: //

9 .) Function of communication Transmitter communication with RS8, MODBUSASC, MODBUSRTU communications capabilities (requires a user specified when ordering). Available through the "8 output communication protocol" parameter is set to specify. Instrument Communication Interface specific technical note on "protocol." 7.Operations.) Panel construction and key definition m /h % m.) Function instructions set parameters confirmation and set key of exit sub- ( key) enter sub- and cancel set key( key) set item DOWN and data variables degression key( set item MOVE and data variables increase key ( key) key) Instructions: Instrument Display Interface. The first line shows an instantaneous flow rate, flow rate display units can be in the 'flow unit' function key to choose;. The second line shows the cumulative total amount and cumulative units;. The third line shows the percentage of traffic 7 Http: //

10 .) construction Mode of Measuree press Configuration Menu press Parameter item Press Secondary Parameter item. PV Units.. BASIC... Damping(s) 0.~ Language... Qmax(m/h).. Low Cutoff%.. Freq Direct.. Freq Max(Hz)... Liter/Pulse. SYSTEM.. Pulse Width(ms).. Pulse Level.. RS8 Ptotocol.. Baudrate. RS8 Output.. Data Bit.. Parity.. Stop Bit.. Dev Address. Total Set. Load Settings.. Clear Total.. FWD preset(m). CALIBRATION. ma Trim. 0mA Trim. TEST. Loop Test. Pulse Test Mode of Measuree Press Configuration Menu press Parameter item Press Secondary Parameter item Press 8 Http: //

11 .) detail parameter instructions parameter item parameter setting range instructions flow unit totalizer unit flow display resolution totalizer display resolution language L/S L/m L/h m/s m/m m/h G/S G/m G/h L m,g chinese english S=second,M=minute, H=hour,L=liter, M=cubic meter,g=gallon set the instantaneous flow of decimal places displayed set the totalizer flow of decimal places displayed scale flow termination of small flow unit m/h this parameter can move small flow display,the percentage for the full range upper frequency limit pulse equivalent pulse width pulse level clear accumulation preset positive accumulation ma calibration 0mA calibration Hz larger than system s minimum is ok ms low effective,high effective No Yes maximum frequency output,it s effectual when pulse equivalent is ZERO one pulse on behalf of how many liters do not need under normal condition clear total accumulation If replace instrument,can input previous totalizer flow,continue to accumulation calibrate output signal without flow. calibrate output signal of full range 9 Http: //

12 ). detail instructions.) Unit of flow Adjust instant flow s unit, the setting rang L/S L/min L/h m/s m/min m/h G/S G/min G/h Steps Operation instructions Interface show In the measurement mode, press into configuration Basic System Calibration Test into Basic PV Units into PV Units PV Units L/h L/h Prees or set the Unit of flow PV Units L/h m /h Current value Modify value Press quit setup,lcd show confirm PV Units ENT ESC L/h m/h to confirm the change to give up modify PV Units 7 two times back to mesurement also you can continue other operation 0 Http: //

13 . )Instantaneous flow Resolution Adjust the instantaneous flow of small points indicate the medium, set the range of - Steps Operation instructions Interface show In the measurement mode, press into configuration Basic System Calibration Test Click into Basic to choice PV decimal PV Units Click into PV decimal Prees or set the nstantaneous flow Resolution Current value Modify value Press quit setup,lcd show confirm ENT ESC to confirm the change to give up modify PV Units 7 two times back to mesurement also you can continue other operation Http: //

14 .) Unit of total Adjust Total unit, setting range L,m,gal Steps Operation instructions Interface show In the measurement mode, press into configuration Basic System Calibration Test Click into Basic to choice l PV Units Click into L m Prees or set the Unit of total L m Current value Modify value Press quit setup,lcd show confirm ENT ESC L m to confirm the change to give up modify PV Units 7 two times back to mesurement also you can continue other operation Http: //

15 . )Cumulative total flow resolution Adjusted cumulative flow dots show the median, set the range of - decimal places Steps Operation instructions Interface show In the measurement mode, press into configuration Basic System Calibration Test Click into Basic to choice PV Units Click into Prees or set the Cumulative total flow resolution current value Modify value Press quit setup, LCD show confirm ENT ESC to confirm the change to give up modify PV Units 7 two times back to mesurement also you can continue other operation Http: //

16 .) Damping time S Damping time on the meter display and output. Set range o -99 9S (unit is "seconds"). Set as follows: Steps Operation instructions Interface show In the measurement mode, press into configuration Basic System Calibration Test Click into Basic to choice Damping(S) Damping(S) Click into Damping(S) Damping(S) Max: 99.9 Min: Prees or and set the Damping time Damping(S) Max: 99.9 Min: current value Modify value Press quit setup, LCD show confirm Damping(S) ENT ESC to confirm the change to give up modify Damping(S) 7 two times back to mesurement also you can continue other operation Http: //

17 . ) system constituent s initial password:000 Steps Operation instructions Interface show In the measurement mode, press into configuration,click to choice System item press the key of,show password interface,enter password,press the key of enter into system constituent Click into Basic System Calibration Test Language Prees or and set the current value Modify value Press quit setup, LCD show confirm ENT ESC to confirm the change to give up modify Language 7 two times back to mesurement also you can continue other operation Http: //

18 7. )Scale flow (m/h) Meter-scale flow (QMAX) range depending on the caliber meter. Scale flow units: m/h. Steps Operation instructions Interface show In the measurement mode, press into configuration,click to choice System item press the key of,show password interface,enter password,press the key of enter into system constituent Press item to choice Basic System Calibration Test Language Language into Qmax(m/h) Low Cutoff% Press into Qmax(m/h),Prees or and set the Scale flow Qmax(m/h) current value 00.0 Max: Min: Modify value 0.0 Press quit setup, LCD show confirm Qmax(m/h) ENT ESC to confirm the change to give up modify Qmax(m/h Low Cutoff% 8 three times back to mesurement also you can continue other operation Http: //

19 8.) Small flow termination%(low %) The parameters on the display and output are valid. When the traffic signal to terminate below the low flow rate (unit%) of the settings to set the value of the The signal will be removed, display and output to zero. The termination of the small percentage is relative to the scale in terms of flow rate settings. Set As follows Steps Operation instructions Interface show In the measurement mode, press into configuration,click to choice System item press the key of,show password interface,enter password,press the key of enter into system constituent Basic System Calibration Test Language Press item to choice Language Press into Press to choice Low Cutoff item Qmax(m/h) Low Cutoff% Press into Low Cutoff%,Prees or and set the Small flow Low Cutoff% Max: 9.9 Min: current value Modify value Press quit setup, LCD show confirm Low Cutoff% ENT ESC to confirm the change to give up modify Qmax(m/h Low Cutoff% 8 three times back to mesurement also you can continue other operation 7 Http: //

20 9.) Frequency upper limit Hz (output frequency range of the instrument Hz) When the Liter/ pulse = 0.0, the case "frequency cap Hz" setting determines the frequency of the output When the Liter/pulse >0.0, the setting of L/P determines the frequency output Steps Operation instructions Interface show In the measurement mode, press into configuration,click to choice System item Basic System Calibration Test press the key of,show password interface,enter password,press the key of enter into system constituent Language Press to choice item Language Press into,press to choice Freq Max(Hz) item Freq Direct Freq Max(Hz) Liter/Pulse PulseWidth(ms Press into Freq Max(Hz),Prees or and set the Frequency upper limit Freq Max(Hz) Max: Min: current value Modify value Press quit setup, LCD show confirm Freq Max(Hz) ENT ESC to confirm the change to give up modify Freq Direct Freq Max(Hz) Liter/Pulse PulseWidth(ms 8 three times back to mesurement also you can continue other operation 8 Http: //

21 0.) Liter/pulse(L/P) Scale corresponding to the current flow of output frequency Current Flow(m/h) /. Current Flow(L/s) Output Frq(Hz) = Liter/pulse(L/P) Liter/pulse(L/P) Steps Operation instructions Interface show In the measurement mode, press into configuration,click to choice System item Basic System Calibration Test press the key of,show password interface,enter password,press the key of enter into system constituent Language Press to choice item Language Press into,press to choice Liter/Pulse item Freq Direct Freq Max(Hz) Liter/Pulse PulseWidth(ms Press into Liter/Pulse,Prees or and set the Liter/Pulse Liter/Pulse Max: Min: current value Modify value Press quit setup, LCD show confirm Liter/Pulse ENT ESC to confirm the change to give up modify Freq Direct Freq Max(Hz) Liter/Pulse PulseWidth(ms 8 three times back to mesurement also you can continue other operation 9 Http: //

22 . ) Cumulate Clear Steps Operation instructions Interface show In the measurement mode, press into configuration,click to choice System item press the key of,show password interface,enter password,press the key of enter into system constituent Press to choice Total Set item Basic System Calibration Test Language RS8 Output Total Set Press into Clear Total Clear Total FWD Preset(m) Press into Clear Total,Prees or set the YES or NO Clear Total NO Yes current value Modify value Press quit setup, LCD show confirm Clear Total ENT ESC NO Yes 7 two times to Clear Total to give up modify Clear Total FWD Preset(m) 8 three times back to mesurement also you can continue other operation 0 Http: //

23 . )Preset total positive Steps Operation instructions Interface show In the measurement mode, press into configuration,click to choice System item press the key of,show password interface,enter password,press the key of enter into system constituent Press to choice Total Set item Basic System Calibration Test Language RS8 Output Total Set Press into Clear Total FWD Preset(m) Press to choice FWD Preset(m) item Clear Total FWD Preset(m) Press into Clear Total,Prees or set the YES or NO FWD Preset(m) Max: Min: Press quit setup Clear Total FWD Preset(m) 7 three times back to mesurement also you can continue other operation Http: //

24 NINGBO KIO FLOW INSTRUMENTS CO.,LTD Add:No.0 Xingye Road Yangming Sci.& Tech.Park,P.R.China Tel: Fax: Post Code:00 Http: //

Efcon Water. Installation & User Manual Electro Magnetic Flowmeter (EMF) Efcon Water compact Electro Magnetic Flowmeter (EMF) Manual Version UK

Efcon Water. Installation & User Manual Electro Magnetic Flowmeter (EMF) Efcon Water compact Electro Magnetic Flowmeter (EMF) Manual Version UK Efcon Water Installation & User Manual Electro Magnetic Flowmeter (EMF) Page 1 Table of content Page 1.1 General 3 1.2 Application area 4 1.3 Transportation 4 1.4 Principle of Operation 4 1.5 Product Description

More information

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display, DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration

More information

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module / - ; 0 PSI Advantages / Benefits Wireless easy mounting and dismounting of sensor head by a Turn & Lock technique 3-wire Hall version to interface directly with PLC's (both NPN and PNP) Easy to connect:

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

Ambient Conditions. Operating Conditions. Pressure

Ambient Conditions. Operating Conditions. Pressure Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version

More information

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement ULTRASONlC FlOWMETER SAMPLE BOOK TYPE:LRF-3300S Concentrating on Flow Measurement Introduction LRF-3300S is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp

More information

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax +49 (0) 9402-9383 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Flow - Rotor Characteristics Applications

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

FLOWPET-EG. Description 1 Accumulated total flow (8-digit) 2 Instantaneous flowrate, L/h (mode:b1) and L/min (mode:b2) Selectable with

FLOWPET-EG. Description 1 Accumulated total flow (8-digit) 2 Instantaneous flowrate, L/h (mode:b1) and L/min (mode:b2) Selectable with GENERAL SPECIFICATION FLOWPET-EG MODEL LS 7 6 7-4 GS.No.GBB323-1-E GENERAL FLOWPET-EG is an OVAL flowmeter primarily intended for use in boiler feed water and fuel oil metering applications. Field proven

More information

Lmag_W803D Battery Powered Electromagnetic Converter. User Manual

Lmag_W803D Battery Powered Electromagnetic Converter. User Manual Lmag_W803D Battery Powered Electromagnetic Converter User Manual March, 2016 CONTENT 1 BRIEF...1 2 CONVERTOR PICTURE... 1 3 DISPLAY AND OPERATION...2 3.1 METER MODE... 3 3.2 METER WAKE-UP...4 3.3 SLEEP

More information

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG GENERAL SPECIFICATION GS.No.GBB323E-5 GENERAL FLOWPET-EG is an OVAL flowmeter primarily intended for use in boiler feed water and fuel oil metering

More information

EN-2018 MAGNETIC FLOW METERS

EN-2018 MAGNETIC FLOW METERS EN-2018 MAGNETIC FLOW METERS www.meatest.com 1 MEASURING PRINCIPLE Having no moving or mechanical parts in the flow profile electromagnetic flow meters cause no pressure drop, are virtually maintenance

More information

RUNYI GROUP. Overview. Features SLW. kind ±0.25%R. Output pulse zero drift and. Compact and. Manufacture Standard. Turbine flow meter

RUNYI GROUP. Overview. Features SLW. kind ±0.25%R. Output pulse zero drift and. Compact and. Manufacture Standard. Turbine flow meter SILVER AUTOMATION INSTRUMENTS HTTP://WWW.SILVERINSTRUMENTS.COM RUNYI GROUP SLW Liquid Turbine Flow Meter 1 Overview SLW series Turbine Flow has its simple structure, light weight, high-accuracy, perfect

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit High performance microflow Coriolis Flowmeter GENERAL SPECIFICATION GS.No. GENERAL Based on the Coriolis technologies accumulated over many years, the OVAL has broadened its current general purpose coriolis

More information

SLW-Tri Series Sanitary Hygienic Liquid Turbine Flow Meter

SLW-Tri Series Sanitary Hygienic Liquid Turbine Flow Meter SLW-Tri Series Sanitary Hygienic Liquid Turbine Flow Meter Overview SLW series Turbine Flow has its simple structure, light weight, high-accuracy, perfect repeatability, sensitivity, easy maintenance and

More information

W803C Battery Powered Electromagnetic Converter. User Manual

W803C Battery Powered Electromagnetic Converter. User Manual W803C Battery Powered Electromagnetic Converter User Manual May,2015 INDEX 1 Brief... - 1-2.Converter Picture... - 1-3 Display and Operation...- 2-3.1 Meter Mode... - 3-3.2 Meter Wake-up... - 4-3.3 Sleep

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

ULTRASONIC FLOW METER FT101

ULTRASONIC FLOW METER FT101 Introduction F t101 is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp on type ultrasonic flowmeter is easy to install and no need to cut off the pipe, that

More information

FLOWPET-NX (Oil Service Mechanical Register)

FLOWPET-NX (Oil Service Mechanical Register) FLOWPET-NX (Oil Service Mechanical Register) GENERAL SPECIFICATION GS.No.GBB322-6-E GENERAL Flowpet-NX is an OVAL flowmeter primarily developed for boiler feed water and fuel oil measurement. Field proven

More information

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm) KMS502F Electromagnetic Flanged Flowmeters (sizes: 25mm to 200mm) FEATURES: For all your water applications including batching. Flanged connection suites ANSI 150lb flanges. Unsurpassed accuracy to ±0.5%

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

Warranty conditions are available on this website: only in English version

Warranty conditions are available on this website:   only in English version THE MOST ACCURATE BATTERY POWERED SYSTEM FLOWIZ ( M L 2 5 2 ) C O N V E R T E R W I T H B A T T E R Y S U P P L Y Warranty conditions are available on this website: www.isomag.eu only in English version

More information

TUF Ultrasonic Flow Meter. One. Overview V =

TUF Ultrasonic Flow Meter. One. Overview V = One. Overview TUF Ultrasonic Flow Meter series ultrasonic flow meter is designed on the theory of low voltage and time difference of multi pulse. It can be used to measure transmission time of ultrasound

More information

User s Manual. F2 Calculator. A metering component for thermal energy applications

User s Manual. F2 Calculator. A metering component for thermal energy applications User s Manual F2 Calculator A metering component for thermal energy applications Rev 08.24.2007 1 Installation 1.1 At delivery F2 calculators are delivered in the Transport Mode. Only the clock is active

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display KMS101W Electromagnetic Wafer Flowmeters with S100 display ideal as resettable/batching meter (sizes: 15mm to 150mm) 0BFEATURES For ADMIXTURE Batching, Shotcrete, Mild-Recycled Water & Selected Chemical

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

RUNYI GROUP AJ FLOW TOTALIZER. Features

RUNYI GROUP AJ FLOW TOTALIZER. Features AJ FLOW TOTALIZER Features Suitable for flow (Heat) displaying, calculating and controlling of all kinds of liquids, single or mixed gases and vapor. Input multiple flow sensor signals (Such as VSF, Turbine,

More information

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite KFS Flap Flow Meter KFS suitable for H, acids, alkalis and gases spring-loaded horizontal or vertical flow direction low pressure loss mainly viscosity independent optional threshold value contacts optional

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Model Sono-Trak Transit Time

Model Sono-Trak Transit Time Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic

More information

Brunata Optuna H. Properties. Counter

Brunata Optuna H. Properties. Counter Brunata Optuna H Brunata Optuna H measures energy consumption in large and small heating and cooling systems as well as combined heating and cooling systems. The meter is compact and belongs to the first

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Characteristics Applications System Evaluation connection Media pressure temperature

More information

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Flowmeter SITRANS FUE80 with CT approval Overview The 2-path flowmeter SITRANS FUE80 comes as battery or mains-powered and is designed to measure water flow in district heating plants, local networks,

More information

Advanced instrumentation solutions crafted with highest precision

Advanced instrumentation solutions crafted with highest precision www.adeptfluidyne.com Advanced instrumentation solutions crafted with highest precision Working Principle The Transit Time Flowmeter utilises two transducers that function as both ultrasonic transmitters

More information

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body Size : Connection Ends : Min Temperature : Max Temperature : DN 50 to 200 Flanged ISO PN 10/16 ( ISO PN16 for DN200 ) 0 C + 50 C Max Pressure : 16 Bars Specifications : Tangential type Dry dial Magnetic

More information

SonoMeter 31 Energy Meters

SonoMeter 31 Energy Meters SonoMeter 31 Energy Meters Description MID examination certificate no.: LT-1621-MI004-023 The Danfoss SonoMeter 31 is a range of ultrasonic, compact energy meters intended for measuring energy consumption

More information

SVM F22. Calculator for heating or cooling applications. Data sheet

SVM F22. Calculator for heating or cooling applications. Data sheet SVM F22 Calculator for heating or cooling applications Data sheet Application area F22 is a flexible calculator designed for measuring and monitoring of small to medium-sized heating or cooling installations.

More information

1. Main Technical Parameters 1.1 Applicable Caliber: DN15-DN300, other caliber agreement supply. Applicable medium: gas, steam and liquid.

1. Main Technical Parameters 1.1 Applicable Caliber: DN15-DN300, other caliber agreement supply. Applicable medium: gas, steam and liquid. VORTEX FLOWMETER Content 1. Main T echnical Parameters 2. Basic Instroduction 3. Meter Wiring 1.1threewire circuit wring 1.2twowire circuit wiring 4. Operation of User Menu 4.1 working screen 4.2 user

More information

mass flowmeter for compressed air

mass flowmeter for compressed air mass flowmeter for compressed air VARIOMASS MF High End electronic for air measurement & analyse - 1 - The VARIOMASS flow meter for compressed air is a comfortable system for air mass flow measurement,

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

Electromagnetic Flowmeter Comet F

Electromagnetic Flowmeter Comet F Electromagnetic Flowmeter Comet F - Exact measurements - Comfortable calibration with PC - No setup elements - No pressure loss - Periodic cleaning of electrodes - Data backup during power failure - Communication

More information

1) What meter do I need in this application?

1) What meter do I need in this application? ELECTRONIC ELECTRONIC Choices 1) What meter do I need in this application? Meter choice is determined by: Level of accuracy required, flowrate, line size, viscosity, fitting type, pressure rating, temperature,

More information

Simplified Operations for TM-3100 Series Digital Tachometer

Simplified Operations for TM-3100 Series Digital Tachometer Simplified Operations for TM-3100 Series Digital Tachometer The TM-3100 series Digital Tachometers has the most fundamental function in rotational measurement of four standard models (rotation speed display,

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

EGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification EGCW Converter for Electromagnetic Flowmeter GENERAL MAGMAX EGCW is the high-performance separate type converter for electromagnetic flowmeters with the compact housing. Improved self-diagnostic functions

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

FAST SAMPLING CONVERTER

FAST SAMPLING CONVERTER FAST SAMPLING CONVERTER ML4-F1 HIGH SAMPLING RATE CONVERTER (UP TO 400 SAMPLES/SECOND) Warranty conditions are available on this website: www.isomag.eu only in English version INDEX TECHNICAL DATA... 3

More information

B r e a k t h r o u g h F l o wmeter Technology. Ultrasonic Flowmeter Range

B r e a k t h r o u g h F l o wmeter Technology. Ultrasonic Flowmeter Range TM B r e a k t h r o u g h F l o wmeter Technology Ultrasonic Flowmeter Range IDEAL FOR: Drink dispensing Laboratory tests Cooling equipment Active flow alarms Semiconductor plant OEM applications Pilot

More information

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

Target disk flowmeter for liquids and gases

Target disk flowmeter for liquids and gases Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight

More information

SVM F27 / C27. Ultrasonic BTU meter for heating or cooling. Data sheet

SVM F27 / C27. Ultrasonic BTU meter for heating or cooling. Data sheet SVM F27 / C27 Ultrasonic BTU meter for heating or cooling Data sheet Application field F27/C27 is a BTU meter for debiting and monitoring energy consumption (F27 for heating and C27 for cooling). F27/C27

More information

+GF+ SIGNET Temperature Transmitter Instructions

+GF+ SIGNET Temperature Transmitter Instructions GF SIGNET 80- Temperature Transmitter Instructions ENGLISH -80.090- B-/00 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal

More information

FLOMID-MX Control unit for electromagnetic flowmeters USERS MANUAL. instrumentación para fluidos. Realitzat: Revisat R+D Electrònic: Aprovat: Data:

FLOMID-MX Control unit for electromagnetic flowmeters USERS MANUAL. instrumentación para fluidos. Realitzat: Revisat R+D Electrònic: Aprovat: Data: instrumentación para fluidos FLOMID-MX Control unit for electromagnetic flowmeters USERS MANUAL Realitzat: Data: Revisat R+D Electrònic: Data: Revisat Of. Comercial: Data: Aprovat: Data: R-MI-Flomid-MX

More information

ATG SERIES Growco Servo Tank Gauges

ATG SERIES Growco Servo Tank Gauges GROWCO INTERNATIONAL ATG SERIES Growco Servo Tank Gauges TOTAL MEASUREMENT SOLUTIONS Bulletin ATG-S-08 Rev 03 The Growco ATG Series servo tank gauges are designed in the most advanced technology with integrated

More information

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions

More information

FLOMID FX Electromagnetic Flowmeter

FLOMID FX Electromagnetic Flowmeter FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics

More information

OVAL FLOWMETER. Meter Size: 52, 53, 55, 56, 57 Double Case Construction with Powerful Magnetic Coupling ( ) Magnetic coupling Outer Housing

OVAL FLOWMETER. Meter Size: 52, 53, 55, 56, 57 Double Case Construction with Powerful Magnetic Coupling ( ) Magnetic coupling Outer Housing OVAL FLOWMETER : 5, 53,, 56, 57 Double Case Construction with Powerful Magnetic Coupling ( ) Liquid GENERAL SPECIFICATION GS.No.GBB5E 7 GENERAL The OVAL flowmeter is a positive displacement type flowmeter

More information

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body Size : Connection End : Min Temperature : Max Temperature : DN 50 to 200 Flanged R.F. PN10/16 0 C ( for cold water type ) + 90 C (for hot water type ) Max Pressure : 16 Bars Specifications : Horizontal

More information

SITRANS F flowmeters SITRANS F US. Flowmeter FUE380 with approval. 4/230 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. Flowmeter FUE380 with approval. 4/230 Siemens FI Overview SITRANS F flowmeters Siemens AG 009 Overview The -track flowmeter SITRANS FUE380 comes as battery or mains-powered and is designed to measure water flow in district heating plants, local networks, boiler

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

wprime TM Series 280W-CI ULTRASONIC WATER METER

wprime TM Series 280W-CI ULTRASONIC WATER METER MEASURE TODAY. ENSURE TOMORROW wprime TM Series 280W-CI Spire Metering offers the latest in Commercial/Industrial ultrasonic metering technology for reliable flow measurement. The rugged 280W-CI water

More information

M-2111 Series Ultrasonic Flow Meter

M-2111 Series Ultrasonic Flow Meter M-2111 Series Ultrasonic Flow Meter High Accuracy/Non-contact Flow Sensing in PFA Key Features Accuracy ± 1% of reading Repeatability ± 0.5% of reading All wetted parts made of New PFA (AP- 211SH) Contamination

More information

E l e c t r o m a g n e t i c f l o w m e t e r s

E l e c t r o m a g n e t i c f l o w m e t e r s E l e c t r o m a g n e t i c f l o w m e t e r s P r o v e n A N D R e l i a b l e F l o w M e a s u r e m e n t 2 MJK MagFlux flow meters combine high accuracy, stability and low maintenance. Without

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Flowmeter SITRANS FUS80 standard Overview Design The -path design of SITRANS FUS80 ensures maximum accuracy under short inlet conditions. The flowmeter consists of a flow sensor pipe, 4 transducers/transducer

More information

Pmag. Features. Compact digital system, for conductive liquids (>5µS/cm), even with a limitated content of suspended solids.

Pmag. Features. Compact digital system, for conductive liquids (>5µS/cm), even with a limitated content of suspended solids. Pmag Electromagnetic flowmeter 825B123B Features Pipe dimension range: DN10 DN1000 Measure range: 30000m 3 /h Fluid conductivity: >5µS/cm Sensor material: SS321 Lining materials: PTFE from

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

Flow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview

Flow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview Flowmeter SITRANS FUS380 standard Overview Design The 2-track design of SITRANS FUS380 ensures maximum accuracy under short inlet conditions. The flowmeter consists of a flow sensor pipe, transducers/transducer

More information

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING ELECTROMAGNETIC FLOW METERS The electromagnetic flow meter is used to measure the flow rate of conductive fluids and waste water. The measurement is independent of the density, viscosity, temperature and

More information

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the

More information

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual SWITCH 600 Series Velocity Flow Sensor Instruction Manual Ultrasonic Velocity Sensor using Doppler Technology Model: FS-600 Manual Release Date: November, 2009 ECHO Process Instrumentation, Inc. CONTENTS

More information

SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER SYSTEM CONFIGURATION

SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER SYSTEM CONFIGURATION ISO-400 ISO-900 SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER Model: ODM-36A FEATURES Microprocessor based 4-wire transmitter suitable for field installation. The unit features isolated inputs

More information

Electromagnetic flowmeter in all metal design Model MIM

Electromagnetic flowmeter in all metal design Model MIM Electromagnetic Flowmeter all metal design measuring monitoring analysing MIM O O For measuring and monitoring of conductive liquids OAccuracy: O < ± (0.8% of reading + 0.5% of full scale) O O Flow and

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual M518 Rev. B Model 1030F Indicator-Totalizer Model 1030F Indicator-Totalizer Installation, Operation and Maintenance Manual Table of Contents General... 1 Installation... 1 Operation... 7 Programming...

More information

815PT Smart Pressure Transmitter

815PT Smart Pressure Transmitter 815PT Smart Pressure Transmitter General Instructions These instructions provide information for installation, process connection, electrical connection, configuration, operation and maintenance of the

More information

4-20mA, 0-10V and general process measuring bargraph displays

4-20mA, 0-10V and general process measuring bargraph displays Page 1 of 6 Digital panel meters Large displays Bargraphs Transmitters 4-20mA, 0-10V process input bargraph displays Display almost any physical variable... The bargraph displays on this page accept most

More information

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016 J Series induq VMM J Series induq VMI J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS J DB_Magnetic_Inductive_Flow_Sensors 5/216 67 Magnetic inductive flow sensors Principle of operation The smart flow

More information

Plug & Play. No Calibration Required

Plug & Play. No Calibration Required No Calibration Required Plug & Play No K-actor Programming Read the User's Manual Carefully before Starting to Use the Unit. All TK Series low Meters are actory Calibrated. Manufacturer reserves the right

More information

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits RHE11 Hazardous Area Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mount Built in safety barriers allow operation with RHM sensor in hazardous area Selectable Metric and English

More information

SVM F27 Compact. Ultrasonic heatmeter. Data sheet

SVM F27 Compact. Ultrasonic heatmeter. Data sheet SVM F27 Compact Ultrasonic heatmeter Data sheet Application field F27 is a heat meter for debiting and monitoring heat energy consumption. F27 is a flexible compact heat meter with an ultra sonic flow

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

WESAN WP E ELECTRONIC METER WOLTMAN

WESAN WP E ELECTRONIC METER WOLTMAN APPLICATION Fully electronic bulk water meter for measuring the flow (cold water up to 30 C) in supply lines with high flow at low pressure loss. Highly accurate recording of all billing data. FEATURES

More information

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS Rev04009 USER MANUAL DEI MODEL USFT-CS USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER The Model USFT-CS is an ultrasonic transit time flow meter designed to accurately and reliably report the flow

More information

SVM F2 Calculator. A small competent calculator for compact or wall montage. Users manual

SVM F2 Calculator. A small competent calculator for compact or wall montage. Users manual SVM F2 Calculator A small competent calculator for compact or wall montage Users manual Users manual F2 1 INSTALLATION... 5 1.1 AT DELIVERY... 5 1.2 CONNECTIONS... 6 2 MOUNTING... 7 2.1 MOUNTING ON A

More information

ULTRAFLOW. Application. Cooling flow sensor. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

ULTRAFLOW. Application. Cooling flow sensor. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range. ULTRAFLOW Cooling flow sensor Ultrasonic flow sensor Compact design Static meter with no moving parts Large dynamic range No wear Exceptionally accurate Longevity Application ULTRAFLOW type 65-T is a static

More information

BATCHMATE 1500 Batch Control Computer Technical Bulletin

BATCHMATE 1500 Batch Control Computer Technical Bulletin TS-5(C) BATCHMATE 5 Batch Control Computer Technical Bulletin DESCRIPTION The BATCHMATE features an 8 digit.55-in. alphanumeric LED display. The pulse input model will accept up to 2, pulses per second

More information

Ultraclean Flow Measurement!

Ultraclean Flow Measurement! ltraclean Flow Measurement! LEVIFLOW TM Series LFS-04: 0 4 l/min LFS-20: 0 20 l/min LFS-08: 0 8 l/min LFS-50: 0 50 l/min LFS-80: 0 80 l/min Flow IN INTRODCTION Piezoelectric Transducer With-Stream Wave

More information

Metal tube variable area flowmeters for gases, liquids and steam

Metal tube variable area flowmeters for gases, liquids and steam Metal tube variable area flowmeters for gases, liquids and steam Metallic with a robust construction, optional in plastic Indication by means of magnetic coupling Linear scales, calibrated in l/h, m3/h,

More information

RCM DIRECT READING FLOWMETER

RCM DIRECT READING FLOWMETER RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:

More information

SonoSelect 10 and SonoSafe 10 Energy Meters

SonoSelect 10 and SonoSafe 10 Energy Meters SonoSelect 10 and SonoSafe 10 Energy Meters Description The Danfoss SonoSelect 10 and SonoSafe 10 are ultrasonic compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

LZYN Triangle Series Mass Flow Meter

LZYN Triangle Series Mass Flow Meter LZYN Triangle Series Mass Flow Meter 1. General LZYN Triangle Series Mass Flowmeter is designed according to the Coriolis Principle.It can be widely used for the process detecting and custody transfor/fiscal

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL Roline L1 Series Humidity - Temperature Transmitters INSTRUCTION MANUAL 20030314 CONTENTS Overview... 3 Operation... 5 Power supply... 5 Operating range and limits... 5 Temperature compensation of the

More information

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE: Unit 1 / 14 Biscayne Way Jandakot WA 6104 P.O. Box 3232, Success WA 6964 Tel: (08) 9414 7666 Fax: (08) 9414 7677 Email: dg@dginstruments.com.au Website: www.dginstruments.com.au A.B.N: 59 113 005 959 DATE:

More information

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Technical Information TI 273T/02/en 60021667 RTD Temperature Sensor omnigrad T -TSM 480, TR 480 Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Application The Omingrad

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information