OVAL FLOWMETER. Meter Size: 52, 53, 55, 56, 57 Double Case Construction with Powerful Magnetic Coupling ( ) Magnetic coupling Outer Housing
|
|
- Griffin Willis
- 6 years ago
- Views:
Transcription
1 OVAL FLOWMETER : 5, 53,, 56, 57 Double Case Construction with Powerful Magnetic Coupling ( ) Liquid GENERAL SPECIFICATION GS.No.GBB5E 7 GENERAL The OVAL flowmeter is a positive displacement type flowmeter comprising a pair of oval gear rotors. It is capable of metering the actual quantity of the material passing through it with a high degree of accuracy over a wide flow range and accepts various kinds of liquids. It s accuracy, reliability and quality has made it a highly valued industrial instrument. FEATURES. Simple design makes this meter easy to disassemble and allows for ease in maintenance and inspection.. Introduction of a powerful magnetic coupling makes this meter compatible with a variety of direct-reading registers and mechanical temperature compensator. 3. Compatible with a variety of pulse generators that allows a wide selection of remote flow instrumentation.. Can accept various kinds of liquids by selecting appropriate meter materials. 5. A complete line of models are available to meet a broad range of pressure and temperature requirements. GENERAL SPECIFICATIONS Item 5, Nominal, mm (inch) 5 (") ( /") 50 (") 50 (") Construction Double case construction Transmission System Magnetic coupling Outer Housing Materials Inner Housing, Rotors SCSA SUS36 FC50, SCS3A Bearings Carbon Linearity ±0.35% or ±0.5% Repeatability ±0.05% or ± 0.0% Operating Temp. Range Liquids to be ed Finish Linearity 5 to + ±0.35% 5 to + C to +0 ±0.5% 5 to +60 C Water, petroleums, chemical liquids, etc. Body, Transmission Gear Box & Register, Case: Munsell.5G 8/ Register Frame: Munsell N.5 Flange Ratings and Max. Operating Pressure: MPa Pressure Rating Housing Material Flange Rating JIS ANSI K 6K K K 63K K NOTE: Reference temperature; C : Special Head Office (Tokyo): Tel Fax International Sales Division SK@oval.co.jp Overseas Branch Offices: Beijing, Seoul, Singapore, Taipei
2 OVAL FLOWMETER : 5 to 57 (Double Case) GBB5E-7 FLOW RANGE Table A Flow Range for Liquid in General (Linearity: ± 0.35%) (Operating temp. range: 5 to + C) Unit in m 3 /h Type of Liquid Water Liquids other than water (Unit in mpa. s) Nominal Bore Operating Condition 60 C max. 60 to C Less than to to to 5 5 to to to Continuous 0.3 to 0. to to. 0. to. 0.3 to. 0.5 to to to to. Intermittent 0.3 to.5 0. to 0.7 to.8 0. to to to 0.08 to 0.08 to to Continuous 0. to 0.7 to.6. to. 0.7 to. 0. to. 0.8 to to to to.5 Intermittent 0. to to. to to to to 0.5 to 0.5 to to 3 Continuous to 5. to.8 to 5.5. to 5.5 to to to to to 6 Intermittent Continuous to 7 9 to. to to 8.8 to to. to to to 8.5 to 0. to 0.9 to to 0.6 to to to to to Intermittent to 8.5 to 3.5 to 7.5 to 7 to to 0.6 to 0.6 to to 5 5 Continuous to 5 to 6 8 to 5 to to to 3. to 3. to 6. to Intermittent to 30 5 to 8 to 35 8 to 35 to 35 to. to. to 3. to Temp., Viscosity Range Table B Flow Range for Liquid in General (Linearity: ±0.5%) (Operating temp. range: 5 to +60 C) Nominal Bore Operating Condition Type of Liquid Temp., Viscosity Range Water 60 C max. Continuous 0.6 to Intermittent 0.6 to.5 Continuous. to Intermittent. to 3 Continuous to 5 Intermittent to 7 9 Continuous to Intermittent to 8 Continuous 7 to Intermittent 7 to Liquids other than water (Unit in mpa. s) Less than to to to 5 5 to, to to 00 to. to.8.6 to..6 to to to to 5. to 7 to to to. 0.7 to.8. to.. to to to to 3.5 to 7 8 to 8 to to. 0.5 to to to to to to 3 to 7 6 to 6 to to to 0. to to 0.6 to to. to 6. to 3 to 3 3 to 0.5 to to 0. to to 0. to 8 0. to 0.9 to to to 3 to 0.5 to to.7 0. to.8 0. to to to to to 7 7 to 6 to 3 3 Unit in m 3 /h 0.5 to. 0.5 to.5 0. to.5 0. to 3 0. to 6 0. to to 0.9 to 5 5 to to High Temp. Liquid Service Flow Range (Linearity: ± 0.35%) (Operating temp. range: in excess of + C up to + 0 C) Nominal Bore Operating Condition Type of Liquid Temp., Viscosity Range Hot Water Continuous 0. to 0.7 Intermittent 0. to 0.9 Continuous 0.7 to. Intermittent 0.7 to.8 Less than 0.3 to. to.8 to. to 3.6 High temp. Liquids other than water (Unit in mpa. s) 0.3 to to to 5 5 to to to. 0.8 to.8. to.. to to. 0.5 to to. 0.9 to to. 0.5 to to to to. 0.5 to to. 0.8 to to. 0.5 to to. 0.8 to 3. Unit in m 3 /h 500 to to 0.5 to to. 0.8 to.7 NOTES:. In the Operating Condition column Continuous means continuous operation; Intermittent means no more than 8 hours operation a day, and indicates allowable instantaneous flow rate.. Flow range should be selected within the Continuous or Intermittent range specified. 3. For applications where viscosity exceeds 00mPa. s (size 57: 0mPa. s), specially machined rotors are used.. For high viscosity liquid more than 00Pa. s, the meter is not applicable, ULTRA OVAL series are recommended instead. 5. Regarding liquid ammonia, consult factory. REGISTERS AND UNIT REGISTRATION Register Model Dial and Pointer Total Counter Volume per Point Rev. (L) Min. Reading (L) Max. Readout (L) LSD Drum (L) Direct-reading Register (LW) Direct-reading Register w/reset Counter (LW5) Resettable Register (LW, 3) (Output Shaft) (Output Shaft) : Standard. As to general specifications registers, refer to individual General Specification Sheets. : Small dial scale reading. (LSD: Least Significant Digit)
3 OVAL FLOWMETER : 5 to 57 (Double Case) GBB5E-7 Unit of Factored Pulse Generated Unit of Unfactored Pulse Generation Volume per Pointer Rev. L/rev Generator Pulse No. Signal Unit 0 0 (L/P) 0 0 P / rev. PGEP PG30SEP Freq. at Max. (Hz) (L/P) P / rev. : Standard : Unacceptable depending on particular specifications. For detailed pulse generator specifications, see individual General Specification sheets. 0. Freq. at Max. (Hz) (L/P) P / rev. PG30EP PG30DEP Freq. at Max. (Hz) P / rev. (L/P) Freq. at Max. (Hz) Full Scale for Indicator or Recorder 56 Max. m 3 /h 00 (Q=36) PG30SEP Nominal Factor (ml/p) Less than Full Scale (m 3 /h) 7.73 (0.5) 7.68 (.3) 5.63 (0.6).0 () 8.0 () 59.7 (.7) () More than Full Scale (m 3 /h).37 (.) 9.5 (.8) Full Scale m 3 /h L/min () TYPICAL PERFORMANCE CHARACTERISTICS error, % Pressure Drop, kpa Gasoline 0.mPa. s Water mpa. s 3 Gas Oil 3mPa. s Fuel Oil 0mPa. s , m 3 /h
4 OVAL MODEL EL00 OVAL FLOWMETER : 5 to 57 (Double Case) GBB5E-7 REGISTERS AND REMOTE INSTRUMENTATION SYSTEMS Direct-coupled Registers and Remote Instrumentation System with Pulse Generator Equipped Totalizer EL0 EL03 Batch Counter EL8 Blender EL3 Multiple Temp. Compensator EL50, EL5 Digital Controller PG EP Pulse Generator (Contact-closure) PG30EP PG30DEP PG30SEP, Voltage Pulse Generator LW Register Factored Pulse Generation Convenient Type Accuracy Adjustor (AF3) LW5 Register Basic Oval Flowmeter Unfactored Pulse Generation Fixed Type Accuracy Adjustor (AG) Conversion Gear Assembly GB PG 30SEP LW Register F/I Converter Converter/ Compensator LW3 Register SU3 EL08 Controller, Analog Instrument Recorder Direct-coupled Registers without Pulse Generator LW Registser LW5 Registser LW, Registser 5,53 only Basic Oval flowmeter Convenient Type Accuracy Adjustor (AF3) Fixed Type Accuracy Adjustor (AG) Conversion Gear Assembly GB NOTES:. For details of the direct-coupled registers, pulse generators, receiving instruments, etc., see individual General Specification Sheets.. Flame-proof construction of pulse generators are available. For intrinsically safe construction, pulse repeater is provided. 3. : 5, 53 could not be installed.
5 OVAL FLOWMETER : 5 to 57 (Double Case) GBB5E-7 DIMENSIONS (Unit in mm) : 5, 53 Drawings below are with register model LW (LW3) High Temp. Version Cooling Fin Provided (exceeding C up to 0 C) (exceeding 80 C for PG30DEP, PG30SEP mounted) 5 3 φ56 D φ56 D L 66 F R 66 F+5 Transmission System Nominal L Flange Rating JIS 30k RF ANSI 50RF R F D Approx. Weight (kg) :, 56, 57 (LW Register Installed) L 66 A F R Transmission Gear Box w/external Accuracy Adjustor (GB-0 ) 5 No. 3 5 Part Name Outer housing Flange Oval Rotors Conversion Gear Ass y Register Pressure ratings 63K 63K 63K F R D A Approx. Weight kg In case of cooling fin coupled, add 5 mm to F above. Flange-to-Flange Dimensions (L) Unit in mm Pres. Rating Flange ratings 63K Pres. Rating Flange ratings 63K Pres. Rating Flange ratings 63K JIS RF JIS K RF JIS 63K RF ANSI 50 RF ANSI 300 RF ANSI 600 RF JIS RF JIS K RF JIS 63K RF ANSI 50 RF ANSI 300 RF ANSI 600 RF JIS RF JIS K RF JIS 63K RF ANSI 50 RF ANSI 300 RF ANSI 600 RF Special
6 OVAL FLOWMETER : 5 to 57 (Double Case) GBB5E-7 Item MODEL CODE EXPLANATION Application Material Code No L K Liquid flowmeter Reference flowmeter, etc. Description B FC50 (Stainless steel), (SUS36 for rotors of and 56) C Construction and Flange Bore st Group Basic Direct-coupled Register Accuracy Adjustor and Mounting Adaptor nd Group Register SCS3A (Cast stainless steel) 5 Nominal size 5mm (") 5 3 Nominal size 5mm (") 5 5 Nominal size mm ( /") 5 6 Nominal size 50mm (") 5 7 Nominal size 50mm (") - Double-case construction Direct-reading register (LW) 5 Direct-reading register w/reset counter, reset pointer (LW5) Resettable register (LW) 3 Resettable register/printer combination (LW3), Accumulative type Fixed type adjustor AG provided. Convenient type adjustor AF3 provided. (Linearity: ±0.5%) Angle adaptor + Fixed type adjustor AG provided. Angle adaptor + Convenient type adjuster AF3 provided. (Linearity: ±0.5%) Cooling fin + Fixed type adjustor AG provided. Cooling fin + Convenient type adjustor AF3 provided. (Linearity: ±0.5%) 9 Others (Angle adaptor is used to mount LW or LW5 register at 5 angle.) (Cooling fin is used in applications where operating temp. exceeds 80 C and PG30EP or PG30SEP pulse generator is added.) Item Housing Material Pressure Rating Code No F 3 (steel casting) 6 63K (Special) Bearings Carbon plain bearings Transmission System - Magnetic coupling Unfactored Pulse Generation Factored Pulse Generation 3rd Group Basic th Group Generator 0 Where pulse generator is not required. Description 7 PG30SEP (Explosionproof) Non-contact pulse (Current pulse) VDC, -wire D 9 Others PG30DEP (Explosionproof) Non-contact pulse (Current pulse) VDC, -wire 0 When pulse generator is not required 5 PG30EP (flameproof configuration) non contact voltage pulse ( VDC, 3 wires) 7 PG30SEP(flameproof configuration)non contact current pulse ( VDC, wires) B D 9 Others PGEP (flameproof configuration) contact pulse (Dry read switch) PG30DEP (flameproof configuration) non contact current pulse ( VDC, wires) 0 Always "0"
7 OVAL FLOWMETER : 5 to 57 (Double Case) GBB5E-7 When making inguiries, Please state following information: Please fill out the following specifications when making inquiries.. Model L. Fluid to be measured Name Viscosity mpa s Specific gravity 3. (m 3 /h) Maximum Normal Minimum. Fluid temperature ( C) Maximum Normal Minimum 5. Ambient temperature ( C) Maximum Normal Minimum 6. Pressure (MPa) Maximum Normal Minimum 7. Flow direction Right Left, Bottom Top 8. Flange connection Nominal diameter mm, Flange rating 9. Required accuracy (Linearity) ± %. Explosion-proof construction Required class Not required. Accessories Strainer, Air eliminator, Companion flange. Quantity Including accessories 3. Receiving device Type, manufacturer, model, specifications (input, output, power supply, etc.). Distance between the flow meter and the receiving device m Remote Instrumentation Automatic Batching Signal type and application (totalizer, indicator, recorder, controller, computer input, data logger input, batch, blend) Quantity per batch, preset full scale Time required for each batch Pulse generator type and signal unit 3 Full scale and unit Flowmeter to receiving instrument distance 5 Power source, voltage, frequency 3 Daily total number of batch Allowable error in each batch 5 Operating air pressure, power source, voltage, frequency 6 Valve used and accessories 6 Receiving instrument
8 OVAL FLOWMETER : 5 to 57 (Double Case) GBB5E-7 The specification as of May, 6 is stated in this GS Sheet. Specifications and design are subject to change without notice. Sales Representative: GS.No.GBB5E 初版改訂印刷
FLOWPET-NX (Oil Service Mechanical Register)
FLOWPET-NX (Oil Service Mechanical Register) GENERAL SPECIFICATION GS.No.GBB322-6-E GENERAL Flowpet-NX is an OVAL flowmeter primarily developed for boiler feed water and fuel oil measurement. Field proven
More informationSLIDE VANE FLOW METER SPECIFICATIONS
SLIDE VANE FLOW METER SPECIFICATIONS V20051 17.09 1. Outline Slide vane flow meter is vane type positive displacement flow meter, creating high accuracy measurement and low pressure loss by decreasing
More informationInexpensive PD for Boiler Feed Water and Oil FLOWPET-EG
Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG GENERAL SPECIFICATION GS.No.GBB323E-5 GENERAL FLOWPET-EG is an OVAL flowmeter primarily intended for use in boiler feed water and fuel oil metering
More informationFLOWPET-EG. Description 1 Accumulated total flow (8-digit) 2 Instantaneous flowrate, L/h (mode:b1) and L/min (mode:b2) Selectable with
GENERAL SPECIFICATION FLOWPET-EG MODEL LS 7 6 7-4 GS.No.GBB323-1-E GENERAL FLOWPET-EG is an OVAL flowmeter primarily intended for use in boiler feed water and fuel oil metering applications. Field proven
More informationInexpensive PD for Boiler Feed Water and Oil FLOWPET-5G
iquid Inexpensive P for oiler Feed Water and Oil FOWPET-5G GENER SPEIFITION GS.No.G324E 1 GENER FOWPET-5G is an OV flowmeter primarily intended for use in boiler feed water and fuel oil metering applications.
More informationGS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit
High performance microflow Coriolis Flowmeter GENERAL SPECIFICATION GS.No. GENERAL Based on the Coriolis technologies accumulated over many years, the OVAL has broadened its current general purpose coriolis
More informationFigure 3. 1 ½ Nutating Disc with R-10 register
Principle of Operation Liquid enters a precision-machined chamber containing a disc which nutates (wobbles). The position of the disc divides the chamber into compartments containing an exact volume. Liquid
More informationNew Single Straight Tube Type OVAL Coriolis Mass Flowmeter. MK Transmitter : ST9101, ST9801. See general performance table (page 2).
New Single Straight Tube Type OVAL Coriolis Mass Flowmeter ST MK : ST90, ST980 GENERAL SPECIFICATION GS.No.GBN034-4-E GENERAL The STmass MKII is a user friendly coriolis mass flowmeter capable of making
More informationSmart Displacer Level (Interface) Transmitter DLT100 Series
Smart Displacer Level (Interface) Transmitter DLT100 Series Equipped with FISHER FIELDVUE DLC3010 1 Introduction DLT100 series is Smart Displacer Level (Interface) Transmitter equipped with the original
More informationHigh Performance Coriolis Flowmeters. Transmitter : MT9411. SUS316L, SUS316L +Alloy C, Alloy C Housing
Liquid Gas High Performance Coriolis Flowmeters Transmitter : MT94 GENERAL SPECIFICATION GS.No.GBN053E 6 GENERAL The know-how and experience gained in our specialized domain of manufacturing flowmeters
More informationRCM DIRECT READING FLOWMETER
RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:
More informationSITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009
Siemens AG 2009 SITRANS F flowmeters Rotary-piston meters Accessory modules Accessory modules For quantity measurements in conjunction with electromechanical and electronic pulse counters As transmitter
More informationStraight-Tube Coriolis Flowmeter
Liquid Straight-Tube oriolis Flowmeter GENERAL SPEIFIATION GS.No. GENERAL Equipped with a sophisticated transmitter (self diagnosis feature, large size display, and field-reconfiguration capability using
More informationMeasuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...
Full Metal Variable Area Flow Meter and Counter for Liquids and Gases monitoring analysing BGN Special versions up to 600 bar O Nominal diameter up to DN 150 S2 Measuring range: 0.5-5.0... 13000-130000
More informationBGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases
All Metal Variable Area Flowmeter and Counter for liquids and gases monitoring analysing BGN Measuring range: 0.5-5.0... 13000-130000 l/h water 0.015-0.15... 240-2400 m³/h air (20 C, 1.013 bar) Accuracy
More informationPhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications
Description The Vortex PhD vortex shedding flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process fluid line (the bluff body). A
More informationDesign and applications
Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:
More informationIntroducing GPI s Latest
Introducing GPI s Latest Electronic Digital Meter GREAT PLAINS INDUSTRIES, INC. WICHITA, KANSAS CALIBRATE DISPLAY MODEL NON-COMMERCIAL GM SERIES FLOWMETER Total Reset Total New Lockout Feature Lockout
More informationRUNYI GROUP. Overview. Features SLW. kind ±0.25%R. Output pulse zero drift and. Compact and. Manufacture Standard. Turbine flow meter
SILVER AUTOMATION INSTRUMENTS HTTP://WWW.SILVERINSTRUMENTS.COM RUNYI GROUP SLW Liquid Turbine Flow Meter 1 Overview SLW series Turbine Flow has its simple structure, light weight, high-accuracy, perfect
More informationKMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display
Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications
More informationKMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display
KMS101W Electromagnetic Wafer Flowmeters with S100 display ideal as resettable/batching meter (sizes: 15mm to 150mm) 0BFEATURES For ADMIXTURE Batching, Shotcrete, Mild-Recycled Water & Selected Chemical
More informationFH CMF Coriolis Mass Flow Meters
FH CMF Coriolis Mass Flow Meters 1. Introduction Coriolis Mass Flow Meters patented and developed by our company (Chinese Patent No. 03119685.3, 03149996.1) are the leading meters for precision flow measurement.
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:
More information1) What meter do I need in this application?
ELECTRONIC ELECTRONIC Choices 1) What meter do I need in this application? Meter choice is determined by: Level of accuracy required, flowrate, line size, viscosity, fitting type, pressure rating, temperature,
More informationSLW-Tri Series Sanitary Hygienic Liquid Turbine Flow Meter
SLW-Tri Series Sanitary Hygienic Liquid Turbine Flow Meter Overview SLW series Turbine Flow has its simple structure, light weight, high-accuracy, perfect repeatability, sensitivity, easy maintenance and
More informationElectro-Magnetic Flowmeters COPA-XE
Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates
More informationMetal tube variable area flowmeters for gases, liquids and steam
Metal tube variable area flowmeters for gases, liquids and steam Metallic with a robust construction, optional in plastic Indication by means of magnetic coupling Linear scales, calibrated in l/h, m3/h,
More informationSight glass window Sight flow indicator
SIGHT GLASS Sight glass components allow operators to safely observe processes inside tanks, pipes, reactors and vessels. When it comes to selecting a sight glass, a wide variety of factors should be considered
More informationG SERIES PRECISION METERS
Precision Meters PRECISION METERS The High Precision Meter line is the most accurate of the FLOMEC Turbine Meters and includes a traditional design. These meters come in a variety of sizes and fitting
More informationStraight-Tube Coriolis Flowmeter. SUS316L Housing. JIS 10, 20K RF, ASME/JPI 150 RF, IDF ferrule Applicable fluid
Liquid Straight-Tube oriolis Flowmeter GENERAL SPEIFIATION GS.No. GENERAL Equipped with a sophisticated transmitter (self diagnosis feature, large size display, and field-reconfiguration capability using
More informationVersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009
VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet 34-VF-03-14 September 2009 Specification Clamp-on technology HONEYWELL S VERSAFLOW stands for continuity and long term reliability. Flow measurement
More informationFull Metal Variable Area Flowmeter and Counter Model BGF
Full Metal Variable Area Flowmeter and Counter for horizontal and vertical mounting measuring monitoring analysing BGF OO Measuring range: 10-100... 6000-60000 l/h water 0.3-3.0... 170-1700 m³/h air (20
More informationSPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER SYSTEM CONFIGURATION
ISO-400 ISO-900 SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER Model: ODM-36A FEATURES Microprocessor based 4-wire transmitter suitable for field installation. The unit features isolated inputs
More informationMagnetic Inductive Flow Sensors VMI Series
Magnetic Inductive Flow Sensors VMI Series SIKA Dr.Siebert & Kühn GmbH & Co. KG Struthweg 7 9 34260 Kaufungen Germany.: +49 5605 803-0 Fax: +49 5605 803-54 e-mail: info@sika.net www.sika.net Magnetic Inductive
More informationOPTIFLUX 1000 Technical Datasheet
OPTIFLUX 1000 Technical Datasheet Electromagnetic flow sensor in sandwich design Lightweight and compact Excellent price performance ratio Quick and easy to install The documentation is only complete when
More informationAmbient Conditions. Operating Conditions. Pressure
Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version
More informationTIDALFLUX 2300 F Technical Datasheet
Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to
More informationE l e c t r o m a g n e t i c f l o w m e t e r s
E l e c t r o m a g n e t i c f l o w m e t e r s P r o v e n A N D R e l i a b l e F l o w M e a s u r e m e n t 2 MJK MagFlux flow meters combine high accuracy, stability and low maintenance. Without
More informationWATERFLUX 3000 Quick Start
WATERFLUX 3000 Quick Start Electromagnetic flowmeter The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000
More informationMagnetic Inductive Flow Sensors induq. Series VMI
Magnetic Inductive Flow Sensors induq Series VMI Free Flow! Compact - cost-effective - robust! The induq from SIKA is a trio of extremly compact, low cost, magnetic inductive fl ow sensors. This new product
More informationTMU. Coriolis Mass Flow Meter. for liquids and gas
Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to
More informationJB/T Translated English of Chinese Standard: JB/T
Translated English of Chinese Standard: JB/T9249-1999 www.chinesestandard.net Sales@ChineseStandard.net MACHINERY INDUSTRY STANDARD OF JB THE PEOPLE S REPUBLIC OF CHINA ICS 17.120 N 12 JB/T 9249-1999 Replacing
More informationTarget disk flowmeters Series DP Metallic flowmeter for liquids and gases
Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions
More informationTarget disk flowmeter for liquids and gases
Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight
More informationAPT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL
WITH DIAPHRAGM SEAL APT3200L Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate Fuel Autrol America
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS MF High End electronic for air measurement & analyse - 1 - The VARIOMASS flow meter for compressed air is a comfortable system for air mass flow measurement,
More informationSakura Endress RCV-1000/1200. Average Temperature Measuring Element for Tank Gauging System
Technical Information TI 002 N/08/en/02.02 Average Temperature Measuring Element for Tank Gauging System RCV-1000/1200 Multi-point average temperature with tank inventory management control Introduction
More informationMPU 200 Series B. Ultrasonic Gas Flowmeter. Specifications. Features. Principle of Operation
Ultrasonic Gas Flowmeter MPU 200 Series B Specifications Issue/Rev. 0.4 (10/11) Bulletin SSKS004 The MPU 200 Series B Ultrasonic Gas Flow Meter is a single path ultrasonic meter with non-intrusive and
More informationFLOMID FX Electromagnetic Flowmeter
FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics
More informationF-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature
F-SERIES Indicators Totalizers Transmitters Flow computers Batch controllers Monitors Flow Level Pressure Temperature FOR F - SERIES F - SERIES F - SERIES F - SERIES F - SERIES F - SERIES F - SERIES F
More informationPTG series Smart Pressure Transmitter
No. SS2-PTG300-0100 PTG series Smart Pressure Transmitter Model PTG71 / PTG72 OVERVIEW The Smart Pressure Transmitter model PTG is a high- performance, highly reliable gauge pressure transmitter. Based
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationWATERFLUX 3000 Quick Start
WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000
More informationHigh Performance Coriolis Flowmeters
iquid Gas High Performance Coriolis Flowmeters GENERA SPECIFICATION GS.No.GBN120E 20 GENERA Equipped with a sophisticated transmitter (self diagnosis feature, large size display, and field reconfiguration
More informationPHILTEC PHILTEC FIBEROPTIC SENSORS FROM INNER SPACE TO OUTER SPACE SOLVE YOUR MEASUREMENT PROBLEMS FIBEROPTIC SENSORS
FROM INNER SPACE TO OUTER SPACE PHILTEC FIBEROPTIC SENSORS SOLVE YOUR MEASUREMENT PROBLEMS PHILTEC FIBEROPTIC SENSORS DISTANCE I DISPLACEMENT I VIBRATION PRODUCT GUIDE PHILTEC A P P L I C AT I O N S Aerospace
More informationwww. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER
www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER 1 www. otech.com.sg EFS801 - CFT181/RFT201 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring
More informationFlow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes
GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax +49 (0) 9402-9383 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Flow - Rotor Characteristics Applications
More informationCRoSS StACK LASeR gas ANALYZeR
DATA SHEET CRoSS StACK LASeR gas ANALYZeR (Dual beam version) Cross stack laser gas analyzer (ZSS) provides continuous measurement of CO and O2 gas concentration with fast response. Since ZSS is installed
More informationMagnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up
Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically
More informationMagnetostrictive Level Transmitter
Magnetostrictive Level Transmitter The Model KMD is an advanced, state-of-the-art, two-wire, Magnetostrictive-based level transmitter suitable for a wide range of process applications. The latest in microprocessor
More informationOPTISONIC Ultrasonic flowmeter for liquids in all industrial applications
OPTISONIC 3400 Ultrasonic flowmeter for liquids in all industrial applications Measurement of conductive and non-conductive, low and high viscous liquids, from -200 to +250 C / -328 to +482 F medium temperature
More informationUltraclean Flow Measurement!
ltraclean Flow Measurement! LEVIFLOW TM Series LFS-04: 0 4 l/min LFS-20: 0 20 l/min LFS-08: 0 8 l/min LFS-50: 0 50 l/min LFS-80: 0 80 l/min Flow IN INTRODCTION Piezoelectric Transducer With-Stream Wave
More informationSITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI
Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the
More informationTEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions
Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof
More informationCROSS STACK LASER GAS ANALYZER
DATA SHEET CROSS STACK LASER GAS ANALYZER (Single beam version) ZSS-S Cross stack laser gas analyzer (ZSS) provides continuous measurement of HCl contained in fl ue gas in waste incineration plants and
More informationField IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter
Data Sheet D-FMP-10D1475W-Y_4 Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter 10D1475W/Y Flowmeter Systems utilizes a smart microprocessor converter. System accuracy of ±0.5% of
More informationFW-9000 series MOST COMPACT & MOST LIGHT SUPER INTELLIGENT SERVO GAUGE OUTLINE FEATURES
MOST COMPACT & MOST LIGHT FW-9000 series SUPER INTELLIGENT SERVO GAUGE OUTLINE FW-9000 SUPER INTELLIGENT TANK GAUGE has been developed based on the technical and field application know-how obtained through
More informationSmith Meter AccuLoad. Electronic Preset Delivery System. Tank Proving Guide. Bulletin MN Issue/Rev. 0.1 (7/10)
Electronic Preset Delivery System Smith Meter AccuLoad Tank Proving Guide Issue/Rev 01 (7/10) Bulletin MN06146 The Most Trusted Name In Measurement Caution The default or operating values used in this
More informationEN-2018 MAGNETIC FLOW METERS
EN-2018 MAGNETIC FLOW METERS www.meatest.com 1 MEASURING PRINCIPLE Having no moving or mechanical parts in the flow profile electromagnetic flow meters cause no pressure drop, are virtually maintenance
More information2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y
RA 9 /6.98 -Way Proportional Logic Cartridge Valve Model FE.. (Series X and X) Size 6... 6... 6 PSI (5 bar)... 75 GPM (8 L/min) RA 9 /6.98 Replaces: 5.9 Characteristics: Single land throttle valve (main
More informationFlow Measurement SITRANS F VA. SITRANS FVA250 variable area meter. 4/382 Siemens FI Overview
Overview Design and mode of operation Like the other units in the range, the SITRANS FVA250 operates according to the variablearea flow tube principle: the flowing medium lifts the conical float in the
More informationHigh-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet
High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N All rights reserved. The contents provided herein must
More informationModel S50-D Density Sensor Specifications
Issue/Rev. 0.1 (4/99) S-Mass Meter S50-D Density Specifications ulletin SS0M020 The S-Mass Density derives its name from the S-shaped tubes of the flow sensor. This patented geometry produces a high signal-to-noise
More informationCoriolis Mass Flow Meter Model TM
Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :
More informationA Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >
A Higher Level of Performance Data Sheet Series 000 Pressure and Level Transmitters For more information, please visit > www.hawkmeasure.com Series 000 000-SAN Cable with separate electronics Description
More informationApplications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.
MEASURE TODAY. ENSURE TOMORROW wprime TM Series 280W-R Applications Revenue metering Residential submetering Commercial buildings Leakage detection AMR / AMI and billing Drive-by metering Features Residential
More informationMagFlux ELECTROMAGNETIC FLOWMETERS BROCHURE EN 3.05 MAGFLUX BROCHURE 1401
MagFlux ELECTROMAGNETIC FLOWMETERS BROCHURE EN 3.05 MAGFLUX BROCHURE 1401 P R O V E N A N D R E L I A B L E F L O W M E A S U R E M E N T 2 MJK MagFlux flow meters combine high accuracy, stability and
More informationFlow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,
DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration
More informationSITRANS P. Transmitters for level. Introduction 1/42. Application
Introduction HK series S series Fig. / transmitters for level, with built-in analog indicator or digital display Application The transmitter with mounting flange measures the level of corrosive and non-corrosive
More informationEC 21 EC RMG Meßtechnik GmbH. Gas Volume Corrector. via Temperature. Volume Correction. via Pressure and Temperature
Gas olume Corrector EC21/EC24 24 EC 21 olume Correction via emperature 04.12 olume Correction via ressure and emperature 0.5 RMG Meßtechnik GmbH ublication No..62 Otto-Hahn-Str. 5 (Germany).O.Box 280 5502
More informationFluxi 2000/TZ. Turbine Gas Meter
Fluxi 000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas. The
More informationTGF2200 Micro Pulse Level Meter
Guided Radar with 2-wire system TGF2200 Micro Pulse Level Meter OUTLINE The TGF2200 series is a unique 2-wire continuous level-measuring instrument using TDR technology. The simple and compact design suitable
More informationSITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview
Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless
More informationGeneral Specifications
General Specifications GS 01F06F01-01EN Model DY Vortex Flowmeter Model DYA Vortex Flow Converter FOUNDATION Fieldbus Communication Type General FOUNDATION Fieldbus is the digital communication line for
More informationPAD - Heavy Duty Differential Pressure Trasmitter
Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:
More informationDRS390 High stability, flange mounting
DRS 390 1 Monocrystalline silicon smart differential pressure transmitter DRS390 High stability, flange mounting Detailed Information Application the flow of gas, vapor and liquid measurement with device
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:
More informationPositive Displacement Flow sensors
JJ Series VZGG JJ Series VZVA JJ Series VZAL JJ Local displays TD5 Positive Displacement Flow sensors DS_Positive_displacement_flow_sensors / 153 Positive displacement flow sensors Gearwheel type flow
More informationBATCHFLUX 5500 C Technical Datasheet
BATCHFLUX 5500 C Technical Datasheet Electromagnetic flowmeter for volumetric filling machines High-stability ceramic measuring tube, therefore extremely long-term stability Optimum hygienic design Only
More informationTGR wire System Guided Radar Gauge. MICRO-PULSE level meter GENERAL FEATURES OPERATION PRINCIPLE
2-wire System Guided Radar Gauge TGR3000 MICRO-PULSE level meter GENERAL TGR3000 series is the 2-wire system Guided Radar Gauge which can continuously measure the level using micro-pulse. The micropulse
More informationDELUXE AIR PRESSURE CASTING MACHINE MODEL # S
DELUXE AIR PRESSURE CASTING MACHINE MODEL # S INSTALLATION 99-002-D4AP 99-002-D4AP-A MAINTENANCE The points to look for in order to obtain a long and trouble free operation are: a. See that the oil fog
More informationStandard Bourdon tube pressure gauges EN 837-1
Standard Bourdon tube pressure gauges EN 871 Application For gaseous and liquid media which are not highly viscous, do not crystallize and are not aggressive to copper alloys. For measuring gas or vapour,
More informationEGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
EGCW Converter for Electromagnetic Flowmeter GENERAL MAGMAX EGCW is the high-performance separate type converter for electromagnetic flowmeters with the compact housing. Improved self-diagnostic functions
More informationIR-829 Infrared Thermometer User Manual
IR-829 Infrared Thermometer User Manual Contents 1. Introduction...2 2. Features...2 3. Application...2 4. Safety...3 5. Field of View...4 6. Specifications...5 7. Meter Description...6 8. LCD Display
More informationConvex Strainers DN PN 80, 100, 200
55 Convex Strainers DN 400-1000 PN 80, 100, 200 Designed for protection of compressor rotor bundle against foreign-object damage. Working medium is non-aggressive natural gas and other non-aggressive media
More informationLZYN Triangle Series Mass Flow Meter
LZYN Triangle Series Mass Flow Meter 1. General LZYN Triangle Series Mass Flowmeter is designed according to the Coriolis Principle.It can be widely used for the process detecting and custody transfor/fiscal
More informationAccuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing TMU S5 Measuring range: 0-60 kg/h 0-2200 t/h water Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040)
More information} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).
ISO-14001 ISO-9001 SPECIFICATION SHEET CP SERIES 2-WIRE TYPE DO TRANSMITTER Models: DCP-20T FEATURES Rigid aluminium enclosure with free angle mounting. Simple operation offers free range setting, auto-calibration,
More informationJ Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016
J Series induq VMM J Series induq VMI J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS J DB_Magnetic_Inductive_Flow_Sensors 5/216 67 Magnetic inductive flow sensors Principle of operation The smart flow
More information