MP85A/ MP85ADP. FASTpress. Data Sheet. Special features MP85A / MP85ADP. B en

Size: px
Start display at page:

Download "MP85A/ MP85ADP. FASTpress. Data Sheet. Special features MP85A / MP85ADP. B en"

Transcription

1 MP85A/ MP85ADP FASTpress Data Sheet Special features 100% quality control of the production process Powerful algorithms for monitoring fitting, testing and press fitting processes Universal twin channel amplifier for many of the usual market sensors with TEDS sensor detection Memory function for results, curves and device settings Convenient integration into the automation system by means of standardized fieldbus interfaces Carrier frequency excitation voltage 4.8 khz Power supply for active transducers 5 or 24 oltage supply, electrically isolated EEPROM 24 A D μp Control inputs and control outputs A D Intelligent signal conditioning and powerful algorithms for monitoring fitting CANopen interface Ethernet interface 10 SSI transdu cer MP85A / MP85ADP Keyboard and display MMC memory card Profibus DP interface (for MP85ADP)

2 Description Integrated quality assurance in production and laboratory With the MP85A, quality assurance can be integrated into the production process. Operational reliability, economic efficiency and product liability are of paramount importance. Permanent monitoring is indispensable, especially when quality assurance is only possible during the actual manufacturing process. Typical examples include: press-fitting fitting riveting and clinching flanging and roller-burnishing MP85A provides all the functions required for full monitoring together with user-friendly, flexible software that enables users to configure variable test sequences without extensive programming knowledge. Performance features and advantages: Easy configuration and commissioning with free parameterization and visualization software (PME Assistant) Download from Support Software Precise process analysis to meet requirements Flexible system for monitoring different workpieces, 31 different device settings and 31 different workpieces/processes Storage of results, curves and statistics, as well as the device settings in the device itself, on a memory card or on an external PC Continuous traceability thanks to integrated process control and the statistics functions of the stored processes Integration via digital inputs/outputs or integrated fieldbus interfaces to primary control systems, such as a PLC control or process control systems Flexible application, tailored for use at manual workstations Expansion of existing machines, easy to install Possible fitting situations Press fitting no part available loose fitted fitted too deep wrong part not fitted Monitoring flanging processes Monitoring riveting processes Clinch monitoring HBM 2

3 Twin channel fitting monitoring Solutions for mounting processes The MP85A(DP) monitors two measured quantities, such as force and displacement or time. Production and machine status can be monitored using the mounting characteristic curve by means of freely adjustable evaluation criteria. This allows the operator to control the quality and the output of production. Monitoring is either continuous by means of a tolerance band or by max. 9 freely definable tolerance windows. The system monitors: thread-in force block force end position limit values the full force vs displacement curve partial process sequences OK / NOK testing controls production and helps to minimize downtime. Warning limits monitor the production process and make it possible to protect the machines. Control signals control start/stop and limit value cutoff either via digital inputs, the Ethernet interface or the Profibus-DP1 interface (optional). All the individual and cumulative results, switching curve curves and switching events (break/make function) are stored. MP85A(DP) function blocks TEDS transducer and amplifier Setting Evaluation criteria Measuring Loading/ Storing Data storage Special functions Measuring/ isualization Immediate utilization of evaluation criteria Sensor data does not need to be set manually when using sensors with TEDS technology The TEDS data is read via the sense leads from the sensor (instead of an additional cable). The cable and the connector can be deployed as usual. The MP85A is ready for use in a matter of seconds 3 HBM

4 Process analysis with tolerance windows / measurement and visualization The following windows are used to evaluate the production process: 1 alarm window Limits at which an alarm is triggered. This window is used to protect the machine. 1 range window Defines the range in which measured values are stored, within which all the other tolerance windows are positioned tolerance windows for analyzing the fitting process. In the case of tolerance windows, there is a free choice of incoming and outgoing sides; the windows can be evaluated in real time. Mean value windows are also possible. Force measuring range Thread in window: Start window operates online (machine protection) Process window: The fitting window monitors the fitting process Mean value window: Monitors the averaged curve within the window. Block window: The end window monitors the block force Thresholds: Thresholds monitor the process curve in real time through a range (threshold). Displacement measuring range Systems of coordinates: Tolerance window coordinates can be defined absolutely or relatively (dynamically). Use the relative system of coordinates if the absolute position of the fitting pieces (e.g. bearing/shaft) is not always the same. It is possible to mix these two windows. Application: Analysis with tolerance windows press-fitting bushes With relative x coordinates, all that is measured is the relative movement as from the start or end position, relative to the x axis of the two fitting pieces. Window relative to the start position Window relative to the block position HBM 4

5 Application: Process analysis with a tolerance band or envelope curve These analyses enable the curve to be partially or consistently monitored. If a single value is outside the range, the test cycle is rated as NOK. With envelope curve analysis, a maximum of 4 segments with different tolerance limits can be selected. First, one or several reference curve(s) are measured (teach in) to which the tolerance band or envelope curve comprising 64 interpolation points is then adapted. The automatic generation of tolerance band or envelope curve based on previously measured process curves can be manually adapted by mouse click later. Force measuring range Displacement measuring range Start and stop conditions The start and stop conditions are used to synchronize measurement control to the production process. The signaling options are via: CANopen, PROFIBUS-DP1, digital input or internal trigger. Start and stop conditions are available for a wide variety of applications, such as: external start and stop signal target value y and overshoot time target value x and overshoot time target value x and target value y standstill recognition stop on reverse motion of channel x Standard IPCs can be used to visualize the process in situ. The device can also be subsequently integrated into existing systems. Connection is made through the CAN or Ethernet interface of the MP85A devices. Connection is made via the CAN, Profibus-DP1 or Ethernet interface of the MP85A devices. 5 HBM

6 Quality control / statistics Quality and tool wear for the fitting process are assessed using statistics functions. Statistics graphics can be called to clearly display the OK and NOK processes. Global statistics with a process counter are grouped by parameter sets. The tolerance window result can be read at a glance for each parameter set. This allows tool wear component tolerances or damage to a machine to be detected early. The graphic windows in Counting can be used to analyze the distribution of the OK and NOK processes individually for each window. Counting automatically calculates the distribution of the minima and maxima with accompanying standard deviation. Statistics data are stored in the device. Data management / loading and storing With the MP8A(DP), it is possible to store and clearly visualize results, curves, statistics and the device settings. This allows processes to be analyzed later on and ensures 100% traceability. You can choose whether to store the data on your PC or on the multimedia card in the device. Storage on an MMC card can be set up as a circular buffer for the last 1000 curves. In both cases, curves and/or results can be stored in ASCII or Qdas format: NOK processes only or OK processes only or all processes The data on the MMC card can then be transcribed to the PC. A protocol providing all information in detail can be printed out for every process, if needed. HBM 6

7 Management of production data Index / component no. MP85ADP production monitoring Internal MMC Ethernet Index / component no. The curve and result data can be stored with a component part number. This allows easy and unambiguous archiving. Utilizing the existing infrastructure Specifications Using the standard Ethernet interface enables networked systems with remote maintenance to be built up. Basic device MP85A / MP85A DP Accuracy class 0,1 Supply voltage DC 24; potential separation from the measuring system (typically 500 DC ) Permissible supply voltage range Power consumption MP85A, typically MP85ADP, typically MP85A / MP85ADP, max. Behavior in the event of a supply voltage failure W W W Automatic data retention after power failure Typical backup battery life (CR2032) for the realtime clock years 5 Evaluation unit specifications Max. number of measured value triplets 4000 (automatic data reduction) (channel x), (channel y), (time) Sampling rate Hz 2400 Start conditions Internal start signal External start signal Target value x Target value y Target value y + Target value y Stop conditions Internal stop signal External stop signal Target value y + overshoot time Target value x + overshoot time Target value x + target value y + overshoot time Standstill recognition Return channel x Process-end conditions External signal Simultaneous with end of start condition Target value x Target value y Target value x and target value y Number of parameter sets / Measurement programs 31 plus factory settings Number of parameter sets on the optional MMC 31 in XML format 1000 in binary format Switching between parameter sets, typ. ms HBM

8 Evaluation Tolerance band Envelope curve Evaluation 64 supporting points, can be adjusted in Calibration mode 4 tolerance ranges, 64 interpolation points, adjusted as required after end of process Max. number of evaluation windows 9 Type of window oblique or straight Evaluation methods per window Real time evaluation (online) Analyzing the course of the curve in the window (min/max) Analyzing the mean x or y value in the window Analyzing vertical and horizontal thresholds (online) x coordinates for the tolerance window absolute or relative to the start position, or relative to the end position y coordinates for the tolerance window absolute or relative to F min of tolerance window 2, relative to F max of tolerance window 2 or relative to F mean of tolerance window 2 Duration of offline evaluation end window, typ. ms 6 Duration of offline evaluation straight window, typ. ms /measurement pair in window Duration of offline evaluation oblique window, typ. ms /measurement pair in window Statistics (separately for each parameter set) Maximum number of fitting processes 4 x 10 9 Number of histogram classes for 2 values 9 per tolerance window (x max, x min, y max, y min ) Transducer and amplifier Carrier frequency khz 4,8 1 % Excitation voltage eff 2,5 5 % Connectable transducers SGs, half and full bridges Inductive half and full bridges, LDTs Potentiometric transducers Input sensitivities Ω mh Ω Measuring range (m/) m/ 0, , Length of transducer cable, max. m 500 Scaling range, max. digits , at 10% of the input measuring range Scaling range, min. digits 100, at 100% of the input measuring range Permissible common mode voltage, max. 5,5 Common mode rejection Hz Hz Hz db db db Linearity deviation % 0.03 Noise voltage, typically Measuring range (m/) Hz Hz Hz Hz μ/ pp μ/ pp μ/ pp μ/ pp 0,1 0, , Sampling rate, max. 1/s HBM 8

9 Measurement frequency range, adjustable 4th order low pass with Bessel characteristic Nominal value fc (Hz) 1 db (Hz) 3 db (Hz) Phase delay (ms) Rise time (ms) Overshoot (%) ,550 0, ,860 0,510 1, ,6 1,11 1, ,9 2,13 1, ,6 4, ,2 8, ,5 16, ,1 10,3 30,2 33, ,1 5, ,6 2, ,5 0,79 1, ,2 0,19 0, ,1 0,09 0, ,05 0,049 0, Shunt calibration m/ 1 3% Effect of operating voltage on zero point on sensitivity % f.s. % f.s Effect of 10K change in ambient temperature on zero point full bridge on zero point half bridge on sensitivity Long-term drift over 48 h (measuring range 4 m/; 0.5 h after activation) μ/ μ/ % Measuring range (m/) , ,05 μ/ 2 DC-voltage transducers Connectable transducers DC voltage transducers, voltage sources Nominal (rated) measuring range 10 Input signal range 10,5 Scaling range, max. digits , at 10% of the input measuring range Scaling range, min. digits 100, at 100% of the input measuring range Internal resistance of the signal source kω 1 Permissible common-mode voltage, max. 2 Measurement frequency range, adjustable ( 1 db) Hz 0, Filter characteristics Bessel, 4th order Linearity deviation % 0.03 Sampling rate, max. 1/s 2400 Incremental transducers Connectable transducers oltage supply 2-channel mode Inputs (F1 ( ), F2 ( ), Ix ( )) Input levels Low level High level Each line to measurement ground, max ,05 Incremental transd. (up/down counter with zero index signal) 5, max. 150 ma or 24, max. 300mA Time division multiplex method Differential inputs (RS422) HBM

10 Hysteresis 0,07 Permissible common mode voltage, max. 7 / +12 Input impedance, typically kω 12 Detection of direction of rotation via 90 o phase shifted signal F2 Input range pulse counting pulses Maximum pulse rate pulses/ s Interval between 2 successive edges F1( ), F2( ) ns 400 Scaling range, max. digits 20 at 1 pulse Scaling range, min. digits 1 at pulses Measurement frequency range, adjustable ( 1 db) Hz 0, Sampling rate, max. 1/s 2400 SSI transducers Connectable transducers oltage supply 2 channel mode Data input D( ) Input levels, data input D ( ) Low level High level Each line to measurement ground, max. Displacement and angle transducers with SSI interface 5, max. 150 ma or 24, max. 300 ma Time division multiplex method Differential input (RS422) Hysteresis 0, Permissible common mode voltage, max Clock output Cl ( ) Differential output voltage Cl( ), without load, max. Differential output voltage Cl( ), RL = 50 ohms, min. Differential output (RS422) 5,8 2 Common mode voltage at Cl ( ), max. 3 Short circuit current, clock output Cl ( ), typically ma 100 Resolution, single turn bits 12, 13 Resolution, multi turn bits 24, 25 Scaling range, max. digits 20 at 1 pulse Scaling range, min. digits 1 at pulses Measurement frequency range, adjustable ( 1 db) Hz 0, Sampling rate, max. 1/s 1200 Baud rates kbaud 100, 200, 500, 1000 Coding Potentiometric displacement transducer Gray code see transducer carrier frequency General specifications Limit value switches Number Reference level 4 per channel Gross Hysteresis % Adjustment accuracy digit 1 Response time, typically (fc=1000 Hz) ms 2 Control outputs Number 4 (MP85ADP) / 8 (MP85A) Function Process OK / NOK, process started/running, process terminated/valid, limit values 1 4, transducer test result, result tolerance window, status MMC, status channel x/y Nominal (rated) voltage, external power supply DC 24 Permissible supply voltage range Maximum output current per output A 0,5 Short circuit current, typically (U ext. = 24, R L 0.1 ohm) A 0,8 Short circuit period unlimited Isolation voltage, typ. DC 500 HBM 10

11 Control inputs Number 1 (MP85ADP) / 5 (MP85A), electrically isolated Function Zero balance, shunt calibration, parameter set selection, start/stop process, transducer test, store/clear statistics Input voltage range LOW Input voltage range HIGH Input current, typically, (High level = 24 ) ma 12 Isolation voltage, typ. DC 500 Ethernet interface Transfer MBit/s TCP/IP, networkable per IEEE802 Transfer rate, max. MBit/s 10 and 100 (automatic selection) Topology (twisted pairs) 2 LED display for revivers Transmitter (RxD/TxD) and link 2 Line lengths, maximum m 100 Cable type UPT category 5 or shielded twisted pair (STP) Connection socket RJ 45 CAN interface Protocol CAN 2.0B; CANopen compatible Hardware bus link to ISO Baud rates Maximum line lengths Termination resistor Connection Multi Media Card (memory card on Flash basis) kbits/s m connectable by switch terminals Function Storage of: parameter sets, curves and results, statistics, circular buffer of last 1000 curves, file transfer to PC Usable types MBytes 8, 16, 32, 64, 128, 256, 512, 1024 Data transmission rate, typically kbytes/ s 2 8 File system Display Type Keyboard Temperature range DOS, FAT format 2 line, 8 character alphanumeric, LCD Touch sensitive keypad with three keys, pressure sensitive Nominal (rated) temperature range o C Operating temperature range o C Storage temperature range o C Degree of protection Dimensions (W x H x D) mm 55 x 146 x 156 Weight, approx. g 800 IP20 Profibus DP interface (MP85ADP only) Protocol Profibus DP Slave, as per DIN Baud rate, max. MBaud 12 Slave address 3 123, set via the keyboard Profibus ID number Hex 699 Configuration data bytes 5 Parameter data, max. bytes 6 (+7DP standard) Function Access to and parameterization of all MP85A functions (remote control) Parameterization (asynchronous) to DP1 standard Input data, max. bytes 142 Output data, max. bytes 40 Update rate, inputs ms 1 (for 4 measured values) Update rate, outputs ms 10, for zeroing, limit values Diagnostic data bytes 48 Profibus connection 9 pin sub-d (DIN ), electrically isolated from power supply and measurement ground 11 HBM

12 Dimensions of the PME modules: Scope of supply 4 plug-in screw terminals, coded Phoenix order number: 1x voltage supply and CAN, 6 pin M STBW 2.5/6 ST 5.08 GY 2 x transducer, 8 pin MCW 1.5/8 ST 3.81 GY 1x In/Out digital, 8 pin MC 1.5/8 ST 3.5 GY FASTpress Suite System CD with: free PME Assistant setup software Online Help with Tricks&Tips Quick Reference Guide for beginners PME Assistant PLUS (demo version of the PME Assistant) including EASYsetup for user administration and EASYteach for statistical process analysis MP85A Toolkit: Function module kit for creating separate interfaces on operator panels via Ethernet under Windows XP, Windows CE and WindowsMobile MULTImonitor (demo version of the production software for simultaneous display of up to 4 checking processes) EASYmonitor CE (demo version of the production software for operation at a terminal with Windows CE operating system) EASYmonitor Mobil (application for operation with a PDA or pocket PC) Accessories (not included among the items supplied): DT85: 1/4 GA b/w display for visualization and parameterization of several MP85As via the CAN interface Multimedia card (MMC), e.g. Sandisk ( Standard flat ribbon cable, 10-pin, 1.27mm grid Modifications reserved. All details describe our products in general form only. They are not to be understood as express warranty and do not constitute any liability whatsoever. Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45, D Darmstadt, Germany Tel.: Fax: support@hbm.com Internet:

MP85A/ MP85ADP. FASTpress. Data Sheet. Special features MP85A / MP85ADP. B en

MP85A/ MP85ADP. FASTpress. Data Sheet. Special features MP85A / MP85ADP. B en MP85A/ MP85ADP FASTpress Data Sheet Special features 100% quality control of the production process Powerful algorithms for monitoring fitting, testing and press-fitting processes Universal twin-channel

More information

EEPROM. Intelligent signal processing and powerful algorithms for acquiring and assessing switching points and closing actions

EEPROM. Intelligent signal processing and powerful algorithms for acquiring and assessing switching points and closing actions MP85A S MP85ADP S EASYswitch Special features 100% quality control of the checking process Powerful algorithms for acquiring and assessing switching points and closing actions Universal twin-channel amplifier

More information

MX440A. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

MX440A. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en MX440A Universal amplifier Data Sheet Special features 4 individually configurable inputs (electrically isolated) Connection of more than 12 transducers technologies Data rate: up to 19,200 Hz 24 bit A/D

More information

MX1615. Data sheet. Bridge/strain gauge amplifier

MX1615. Data sheet. Bridge/strain gauge amplifier MX1615 Bridge/strain gauge amplifier Data sheet Special features 16 individually configurable inputs Connection of strain gauges in quarter-, half- and full-bridge Bridge excitation : DC or carrier frequency

More information

MX840B R. Data sheet. Ultra-rugged universal amplifier CAN. Special features. Block diagram. B en

MX840B R. Data sheet. Ultra-rugged universal amplifier CAN. Special features. Block diagram. B en MX840B R Ultra-rugged universal amplifier Data sheet Special features 8 individually configurable inputs (electrically isolated) Connection of more than 16 technologies per channel Sampling rates of up

More information

electronics Data Sheet Industrial Amplifier Special features Dimensions (in mm; 1 mm= inches) B en

electronics Data Sheet Industrial Amplifier Special features Dimensions (in mm; 1 mm= inches) B en C l i p electronics Industrial Amplifier Data Sheet Special features Amplifier and additional units for strain gauge full bridges and inductive half and full bridges Modules for mounting onto support rails

More information

CANHEAD. Data Sheet. Special features. Distributed measurement acquisition. B en

CANHEAD. Data Sheet. Special features. Distributed measurement acquisition. B en CANHEAD Data Sheet Special features 10channel amplifier modules for installation close to measuring points Measured data transmission to communication master via field bus Base modules for individual SGs,

More information

MX1601B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

MX1601B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en MX1601B Universal amplifier Data Sheet Special features 16 individually configurable inputs (electrically isolated) Connection of of standard signals (60, 10, 100 m, 20 ma, IEPE) Individual data rates

More information

MX1615B R. Data Sheet. Ultra-rugged Bridge Amplifier

MX1615B R. Data Sheet. Ultra-rugged Bridge Amplifier MX1615B R Ultra-rugged Bridge Amplifier Data Sheet Special features 16 individually configurable inputs Connection of strain gages in quarter-, half- or full-bridge Bridge excitation: DC or carrier frequency

More information

MX1616B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

MX1616B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram MX1616B Strain gauge bridge amplifier Special features - 16 individually configurable inputs - Connection of strain gauges in full-, halfand quarter-bridge (350 or 1,000 Ohm) - Bridge excitation : DC or

More information

Data sheet. P3 Top Class BlueLine. P3MBP BlueLine. Ultra-high pressure transducers to 15,000 bar. Special features

Data sheet. P3 Top Class BlueLine. P3MBP BlueLine. Ultra-high pressure transducers to 15,000 bar. Special features Ultra-high pressure transducers to 1,000 bar Data sheet Special features P Top Class BlueLine PMBP BlueLine - For static and dynamic pressure variance, pressure peaks and pressure fluctuations - Principle

More information

MX1615B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

MX1615B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram MX1615B Strain gauge bridge amplifier Special features - 16 individually configurable inputs - Connection of strain gauges in full-, half-, or quarter-bridge (120 or 350 Ohm) - Bridge excitation : DC or

More information

T10F. Data Sheet. Torque Flange. Special features. Installation example T10F. B en

T10F. Data Sheet. Torque Flange. Special features. Installation example T10F. B en T10F Torque Flange Data Sheet Special features Extremely short design High permissible dynamic loads High permissible transverse forces and bending moments Very high torsional stiffness Contactless Selectable

More information

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en T10FS Torque Flange Data Sheet Special features Nominal (rated) torques: 100 NVm, 200 NVm, 500 NVm, 1 knvm, 2 knvm, 3 knvm, 5 knvm, 10 knvm Nominal speed from 12,000 rpm to 24,000 rpm Low rotor weights

More information

Multipoint measuring units UPM100 and Centipede100

Multipoint measuring units UPM100 and Centipede100 OTTINGER ALDWIN ESSTECHNIK HBM Mess- und Systemtechnik GmbH Multipoint measuring units UPM100 and Centipede100 S 33.UPM100.10 e Multipoint measuring units UPM100 and Centipede100 HBM s multipoint measurement

More information

Inductive Standard Displacement Transducers

Inductive Standard Displacement Transducers WA Inductive Standard Displacement Transducers Special features - Available as displacement probe or with detachable plunger - Good thermal stability in the event of temperature gradients - Space saving,

More information

MX460B-R. Rugged pulse and frequency measuring module. Data sheet. Special features. Block diagram

MX460B-R. Rugged pulse and frequency measuring module. Data sheet. Special features. Block diagram MX460B-R Rugged pulse and frequency measuring module Special features - Four individually configurable inputs (electrically isolated) - Measure any kind of digital signals up to 1 Mhz for measurement of

More information

E *) F 15. H 12 h9. 5.5f7 8h6. a./f approx. 0.5mm Free stroke. Displacement. Initial stroke

E *) F 15. H 12 h9. 5.5f7 8h6. a./f approx. 0.5mm Free stroke. Displacement. Initial stroke Displacement probe Plunger WA Inductive Standard Displacement Transducers Special features Displacement probe and transducer with detachable plunger Good thermal stability in the event of temperature gradients

More information

MX1615B-R. Ultra-rugged Bridge Amplifier. Special features. Data sheet. Block diagram

MX1615B-R. Ultra-rugged Bridge Amplifier. Special features. Data sheet. Block diagram MX1615B-R Ultra-rugged Bridge Amplifier Special features - 16 individually configurable inputs - Connection of strain gages in half-, full- or quarter-bridge (120 Ohm or 350 Ohm) - Bridge excitation: DC

More information

CPU. BM40, BM40PB, BM40IE Industrial amplifier. Special features. Data sheet. Block diagram

CPU. BM40, BM40PB, BM40IE Industrial amplifier. Special features. Data sheet. Block diagram Industrial amplifier Special features - Freely configurable measurement channel with TEDS channel parameterization - Connection of 7 transducer technologies with a 19.2 KHz sample rate - Accuracy class

More information

C10. Data sheet. Force transducer. Special features. B de

C10. Data sheet. Force transducer. Special features. B de C10 Force transducer Data sheet Special features Force transducer for static and dynamic applications Made of non-rusting materials Precise (accuracy class from 0.03) Numerous options (double bridge, TEDS,

More information

MX1615B. Data sheet. Bridge/strain gauge amplifier

MX1615B. Data sheet. Bridge/strain gauge amplifier MX1615B Bridge/strain gauge amplifier Special features 16 individually configurable inputs Connection of strain gauges in quarter-, half- and full-bridge Bridge excitation : DC or carrier frequency Internal

More information

T12. Data sheet. Digital Torque Transducer. Special features. Signal flow block diagram. B en

T12. Data sheet. Digital Torque Transducer. Special features. Signal flow block diagram. B en T12 Digital Torque Transducer Data sheet Special features Nominal (rated) torques 100 N m, 200 N m, 500 N m, 1 kn m, 2 kn m, 3 kn m, 5 kn m and 10 kn m Nominal (rated) rotational speeds from 10 000 rpm

More information

Specifications Type WA2 WA10 WA20 WA50 WA100 WA200 WA300 WA500 Nominal displacement mm Nomi

Specifications Type WA2 WA10 WA20 WA50 WA100 WA200 WA300 WA500 Nominal displacement mm Nomi Displacement probe WA Inductive Standard Displacement Transducers Special features Data Sheet Plunger Displacement probe and transducer with detachable plunger Good thermal stability in the event of temperature

More information

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en T40FM Torque flange Special features Data Sheet - Nominal (rated) torque: 15 kn m, 20 kn m, 25 kn m, 30 kn m, 40 kn m, 50 kn m, 60 kn m, 70 kn m and 80 kn m - Nominal (rated) rotational speed up to 8000

More information

MX1601B R. Data Sheet. Ultra-rugged Standard Amplifier

MX1601B R. Data Sheet. Ultra-rugged Standard Amplifier MX1601B R Ultra-rugged Standard Amplifier Data Sheet Special features 16 individually configurable inputs (electrically isolated) Support of 60 V, 10 V, 100 mv, 20 ma or IEPE on all channels Sample rate:

More information

U10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch]

U10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch] U10M Force Transducer Special features - Precise and robust tensile/compressive force transducer for static and dynamic measurement tasks - High lateral force and bending moment stability, the effect of

More information

MX1601B-R. Ultra rugged Standard Amplifier. Data sheet. Special features. Block diagram

MX1601B-R. Ultra rugged Standard Amplifier. Data sheet. Special features. Block diagram MX1601B-R Ultra rugged Standard Amplifier Special features - 16 individually configurable inputs (electrically isolated) - Support of 60 V, 10 V, 100 mv, 20 ma or IEPE on all channels - Sample rate: up

More information

T12. Digital Torque Transducer. Data Sheet. Special features. Block diagram signal flow. B en

T12. Digital Torque Transducer. Data Sheet. Special features. Block diagram signal flow. B en T12 Digital Torque Transducer Data Sheet Special features Nominal (rated) torques of 100 NVm, 200 NVm, 500 NVm, 1 knvm, 2 knvm, 3 knvm, 5 knvm and 10 knvm Nominal (rated) speeds from 10,000 rpm to 18,000

More information

Product type designation. General information. Hardware product version 01. Firmware version V2.6. Engineering with. update.

Product type designation. General information. Hardware product version 01. Firmware version V2.6. Engineering with. update. 6ES7313-6CF03-0AB0 SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 64 KBYTE WORKING MEMORY, FRONT CONNECTOR

More information

Product type designation. General information. Supply voltage

Product type designation. General information. Supply voltage Data sheet SIMATIC S7-300, CPU 313C, COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO 1 PT100, 3 FAST COUNTERS (30 KHZ), INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, FRONT CONNECTOR (2 X 40PIN)

More information

MGCplus. Measuring amplifier system. Special features. Data sheet

MGCplus. Measuring amplifier system. Special features. Data sheet MGCplus Measuring amplifier system - Up to 128 channels per MGCplus enclosure (256 or 512 with CANHEAD or CAN) - Sampling rates up to 19.2 ks/s per channel - Simultaneous and parallel measurement with

More information

T40B. Torque Flange. Special features. Data sheet. Overall concept

T40B. Torque Flange. Special features. Data sheet. Overall concept T40B Torque Flange Special features - Nominal (rated) torques 50 N m, 0 N m, 200 N m, 500 N m, 1 kn m, 2 kn m, 3 kn m, 5 kn m and kn m - Nominal rated rotational speed up to 24000 rpm (depending on nominal

More information

U2B. Data sheet. Force Transducer. Special features. B en

U2B. Data sheet. Force Transducer. Special features. B en U2B Force Transducer Special features Data sheet Tensile/compressive force transducer Non-rusting, degree of protection IP67 Can be configured with different cable lengths, plug fitting and TEDS on request

More information

T40FH. Torque flange. Special features. Data sheet

T40FH. Torque flange. Special features. Data sheet T40FH Torque flange Special features - Nominal (rated) torques: 100kNm, 125kNm, 150kNm, 200kNm, 250kNm, 300kNm - Nominal (rated) rotational speed of 2000 rpm up to 3000 rpm - Compact design - Version for

More information

MDEX. on customized sensors. Technical information. Torque transducer. CS-T-04-MDEX Special features

MDEX. on customized sensors. Technical information. Torque transducer. CS-T-04-MDEX Special features MDEX Torque transducer CS-T-04-MDEX Special features - Explosion proof acc. to ATEX 95 - Exx II 2 G Ex deq IIC T4 - Nominal (rates) torque of 100kNm, 130kNm and 150kNm - HBM Accuracy Class 0,1 - Digital

More information

This data sheet is only valid in association with the IL SYS INST UM E user manual.

This data sheet is only valid in association with the IL SYS INST UM E user manual. Inline counter terminal, version for extreme conditions, 1 counter input, 1 control input, 1 output, 24 V DC, 500 ma Data sheet 106148_en_03 PHOENIX CONTACT 2015-11-04 1 Description The terminal is designed

More information

Data sheet CPU 314ST/DPM (314-6CF02)

Data sheet CPU 314ST/DPM (314-6CF02) Data sheet CPU 314ST/DPM (314-6CF02) Technical data Order no. Type 314-6CF02 CPU 314ST/DPM General information Note - Features SPEED-Bus SPEED7 technology, SPEED-Bus 8 x DI, 8 x DIO, 4 x AI, 2 x AO, 1

More information

U2B. Force Transducer. Special features. Data sheet

U2B. Force Transducer. Special features. Data sheet U2B Force Transducer Special features - Tensile/compressive force transducer - Non rusting, degree of protection IP67 - Can be configured with different cable lengths, plug fitting and TEDS on request

More information

U9C. Data sheet. Force Transducer. Special features. B en

U9C. Data sheet. Force Transducer. Special features. B en U9C Force Transducer Data sheet Special features Tensile/compressive force transducer Accuracy class 0.2 Nominal (rated) forces 50 N 50 KN Non-rusting, protection class IP67 Configurable with different

More information

Data sheet CPU 313SC (313-5BF13)

Data sheet CPU 313SC (313-5BF13) Data sheet CPU 313SC (313-5BF13) Technical data Order no. Type 313-5BF13 CPU 313SC General information Note - Features SPEED-Bus - SPEED7 technology 24 x DI, 16 x DO, 4 x AI, 2 x AO, 1 x AI Pt100 128 kb

More information

The new dimension in torque measurement

The new dimension in torque measurement Digital torque measurement system The new dimension in torque measurement T12 The digital measurement system Torque Rotational speed Power smarttorque T12 The complete torque in a single transducer SIEMENS

More information

MX440B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

MX440B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en MX440B Universal amplifier Data Sheet Special features 4 individually configurable inputs (electrically isolated) Connection of more than 16 different transducer types Individual data rates up to 40kHz

More information

U15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants

U15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants U15 Force transducer Special features - Tensile/compressive force transducer - Nominal (rated) forces 2.5 kn to 2.5 MN - lass 0.5 to ISO 376 in force measurement range between 10% and 100% of the nominal

More information

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC) 6ES7214-1AG31-0XB0 Page 1 Product data sheet 6ES7214-1AG31-0XB0 SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V

More information

T22. Data Sheet. Torque transducer. Special features. Installation example with two bellows couplings. B en

T22. Data Sheet. Torque transducer. Special features. Installation example with two bellows couplings. B en T22 Torque transducer Data Sheet Special features - Nominal (rated) torques N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m, 00 N m and 1 kn m - Nominal (rated) rotational speeds of 9000 rpm to 16 000 rpm

More information

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0 Digibar II: PE00, PE50 Digital pressure gage Special features Data Sheet PE00 PE50 Operated as manometer with battery operation and Operated as pressure measurement transmitter with 420 current output,

More information

Data sheet CPU 013C (013-CCF0R00)

Data sheet CPU 013C (013-CCF0R00) Data sheet CPU 013C (013-CCF0R00) Technical data Order no. 013-CCF0R00 Type CPU 013C Module ID - General information Note - Features SPEED7 technology 16 x DI, 12 x DO, 2 x AI, from which are 4 input channels

More information

Data sheet VIPA CPU 314SC DPM (314-6CG23)

Data sheet VIPA CPU 314SC DPM (314-6CG23) Data sheet VIPA CPU 314SC DPM (314-6CG23) Technical data Order no. Type 314-6CG23 VIPA CPU 314SC DPM General information Note - Features Powered by SPEED7 Work memory [KB]: 512...2.048 Onboard 24x DI /

More information

MX460B. Data sheet. Pulse and Frequency Measurement Module. Special features. Block diagram. B en

MX460B. Data sheet. Pulse and Frequency Measurement Module. Special features. Block diagram. B en MX460B Pulse and Frequency Measurement Module Data sheet Special features 4 individually configurable inputs (electrically isolated) Measure any kind of digital pulses up to 1 Mhz for measurement of speed,

More information

imc C-SERIES: CS-1016-N, CL-1032-N

imc C-SERIES: CS-1016-N, CL-1032-N imc C-SERIES: -1016-N, -1032-N Intelligent compact measurement device for voltage measurement with extensive additional equipment device type:, 16 analog channels device type:, 32 analog channels Data

More information

MX410B. Highly dynamic universal amplifier. Data sheet. Special features. Block diagram

MX410B. Highly dynamic universal amplifier. Data sheet. Special features. Block diagram MX410B Highly dynamic universal amplifier Special features - 4 individually configurable inputs (electrically isolated) - Connection of more than 5 transducer technologies - Individual sample rates up

More information

C9C. Force Transducer. Special features. Data sheet

C9C. Force Transducer. Special features. Data sheet C9C Force Transducer Special features - Compact design compressive force transducer - Accuracy class 0.2 - Nominal (rated) forces 50 N to 50 kn - Configurable with different cable lengths, plug assembly

More information

EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD.

EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD. KYOWA ELECTRONIC INSTRUMENTS CO., LTD. COMPACT RECORDER EDS-400A Compact Dynamic Strain Recorder Entering the scene in advanced measurement of strain, vibration, pressure, load, etc. New www.kyowa-ei.co.jp

More information

Q.raxx A101-8 slimline RS / EC

Q.raxx A101-8 slimline RS / EC The Q.raxx slimline product is based on the standardized 19 technology, one rack mount unit (1 U) and is designed for measurements with a high level of flexibility, reliability and accuracy in the field

More information

MX840B. Data Sheet. Universal amplifier CAN. Special features. Block diagram. B en

MX840B. Data Sheet. Universal amplifier CAN. Special features. Block diagram. B en MX840B Universal amplifier Data Sheet Special features 8 individually configurable measurement channels (electrically isolated) Connection of more than 16 transducer technologies per channel Individual

More information

General information. Supply voltage

General information. Supply voltage Data sheet SIMATIC S7-300, CPU 314C-2 DP COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 192 KBYTE WORKING MEMORY,

More information

Ranges >500 mm: L10 = ±0.10 % f.s. L02 = ±0.02 % f.s. Ranges 500 mm: L10 = ±0.5 mm L02MM = ±0.2 mm Repeatability ±3 µm

Ranges >500 mm: L10 = ±0.10 % f.s. L02 = ±0.02 % f.s. Ranges 500 mm: L10 = ±0.5 mm L02MM = ±0.2 mm Repeatability ±3 µm Flat Profile Housing with Analog POSICHRON position sensor Only 12 mm height and 36 mm width Protection class IP64 Measurement range 0... 100 to 0... 5750 mm Absolute position measurement Ultra flat profile

More information

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire POSICHRON Position Sensor Stick Design with Analog Specifications POSICHRON position sensor in stick design Protection class IP67 Measurement range 0... 100 up to 0... 5750 mm Absolute position measurement

More information

Data Sheet. Absolute pressure transducer Nominal (rated) pressure 10 bar to 3000 bar. Special features

Data Sheet. Absolute pressure transducer Nominal (rated) pressure 10 bar to 3000 bar. Special features P3 Top Class P3MB version with fixed cable P3MBP version with plug connection TEDS: Transducer Electronic Data Sheet P3 Absolute pressure transducer Nominal (rated) pressure 10 bar to 3000 bar Special

More information

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I Harmonics Temperature input Measurement accuracy 0.5 Memory 4 MByte UMG 104 Energy measurement device for DIN rails Communication Profibus (DP / V0 optional) Modbus RTU Power quality Harmonics up to 40th

More information

Operating manual. 600 Hz Measuring Amplifier ME30. A en

Operating manual. 600 Hz Measuring Amplifier ME30. A en Operating manual 600 Hz Measuring Amplifier ME30 ME30 Contents 3 Page Safety instructions............................................. 4 1 Measuring Amplifiers on Eurocards ME30.................... 8

More information

Q.raxx A slimline RS / EC

Q.raxx A slimline RS / EC The Q.raxx slimline product is based on the standardized 19 technology, one rack unit (1 U) and is designed for measurements with a high level of flexibility, reliability and accuracy in the field of stationary

More information

Torque Measurement T12 The Digital Torque Transducer

Torque Measurement T12 The Digital Torque Transducer Torque Measurement T12 The Digital Torque Transducer Photos 21.11.2014, Folie 2 Hottinger Baldwin Messtechnik GmbH Rainer Schicker Trade name smarttorque Effective until 2013-02-28 Extension by 10 years

More information

100 h; (min. 70 h at 40 C); 200 days (typ.) with optional battery module Memory Number of memory modules (optional)

100 h; (min. 70 h at 40 C); 200 days (typ.) with optional battery module Memory Number of memory modules (optional) CPUs CPU 226 6ES7 216-2AD23-0XB0 Supply voltages Rated value 24 V DC Yes Permitted range, lower limit 20.4 V permissible range, upper limit 28.8 V 120 V AC Yes 230 V AC Yes permissible range, lower limit

More information

servo ARS2000 openconcepts

servo ARS2000 openconcepts servo ARS2000 openconcepts Universal servo positioning controller ARS 2000 The Company Metronix has developed, produced and distributed innovative drive technology for industrial machines and automotive

More information

Intelligent Drive Systems, Worldwide Services SK 700E F 3070 GB

Intelligent Drive Systems, Worldwide Services SK 700E F 3070 GB Intelligent Drive Systems, Worldwide Services SK 700E Universal application Modular High-Performance Inverter NORDAC SK 700E The NORDAC SK 700E frequency inverter is designed for the power range between

More information

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03 Electronic AC Load Series 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A Rev. 3.03 Electronic AC Loads, Series Interface overview RS-232 USB GPIB LAN System bus Analog / Analog isolated X X Standard

More information

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits ISOBE5600 Isolated Probe Systems - ISOBE5600 Isolation system - ISOBE5600 Transient recorder Data sheet Features and Benefits ISOBE5600 Isolation system - Cost-effective - Fiber-optic isolation - Analogue-in

More information

Portable Multi-Channel Recorder Model DAS240-BAT

Portable Multi-Channel Recorder Model DAS240-BAT Data Sheet Portable Multi-Channel Recorder The DAS240-BAT measures parameters commonly found in process applications including voltage, temperature, current, resistance, frequency and pulse. It includes

More information

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I Memory 256 MB Alarm management Residual current measurement Homepage Ethernet-Modbus gateway BACnet (optional) UMG 96 RM-E Power analyser with Ethernet and RCM Communication Modbus (RTU, TCP, Gateway)

More information

T22. Torque transducer. Special features. Data sheet

T22. Torque transducer. Special features. Data sheet T22 Torque transducer Special features - Nominal (rated) torques 0.5 Nm, 1 Nm, 2 Nm, 5 Nm, Nm, Nm, 50 Nm, 0 Nm, 0 Nm, 500 Nm and 1 knm - Nominal (rated) rotational speed up to 000 rpm (depending on measuring

More information

maxon document number:

maxon document number: maxon document number: 791272-04 1 Table of contents... 2 2 Table of figures... 3 3 Introduction... 4 4 How to use this guide... 4 5 Safety Instructions... 5 6 Performance Data... 6 6.1 Motor data... 6

More information

Operating manual. Digital Transducer-Electronics AED 9301A. Part 1, Profibus basic device

Operating manual. Digital Transducer-Electronics AED 9301A. Part 1, Profibus basic device Operating manual Digital Transducer-Electronics AED 9301A Part 1, Profibus basic device 1/24 Part 1 Description of the hardware of the AED9301A-basic device Contents Page Safety Notes... 3 1 Introduction

More information

SIMPLY PRECISE PRELIMINARY. Preliminary product overview - LAK encoder. LAK 1 Absolute linear encoder with signal control

SIMPLY PRECISE PRELIMINARY. Preliminary product overview - LAK encoder. LAK 1 Absolute linear encoder with signal control PRELIMINARY Preliminary product overview - LAK encoder LAK 1 Absolute linear encoder with signal control 2 Index 1. Overview 3 2. Applications 3 3. Technical data 4 4. General specifications 5 5. Dimensions

More information

0.04 mm Distance/revolution mm ±0.05% f. s.; ±0.01% f. s. as option. Measurement range (in mm) 2500 (smaller measurement ranges included)

0.04 mm Distance/revolution mm ±0.05% f. s.; ±0.01% f. s. as option. Measurement range (in mm) 2500 (smaller measurement ranges included) WS58C Absolute Encoder Output Very compact position sensor Measuring range 0... 2500 mm With absolute encoder output High precision linearity up to ±0.01 % full scale Specifications Output for 12 bit/revolution

More information

Protection class. Male 8 pin socket M12 (ADCANOP: 5 pin socket)

Protection class. Male 8 pin socket M12 (ADCANOP: 5 pin socket) WS10SG Analog, SSI or CANopen Output Very compact sensor for industrial applications Protection class IP65 Measurement range 0... 100 mm to 0... 1250 mm Analog output or A/D converted synchronous serial

More information

POSICHRON position sensor in a stainless steel pressure case. Voltage: V, 3 wire Current: ma, 3 wire

POSICHRON position sensor in a stainless steel pressure case. Voltage: V, 3 wire Current: ma, 3 wire Rod Profile with Analog Specifications POSICHRON position sensor in a stainless steel pressure case Protection class IP68 Compression-proof up to 15 bar Measurement range 0... 100 to 0... 5750 mm Absolute

More information

JUMO Wtrans Receiver with Wireless Data Transmission

JUMO Wtrans Receiver with Wireless Data Transmission Data Sheet 902931 Page 1/10 JUMO Wtrans Receiver with Wireless Data Transmission k For measuring temperature, pressure, potentiometer, and voltage. k Interface RS485 with Modbus protocol k Wireless measured

More information

2A (recommended) Power loss

2A (recommended) Power loss Technical Data CPU 314SC/DPM Module name Dimensions and weight Dimensions W x H x D 120 x 125 x 120mm Weight 610g Voltages, Currents, Potentials Power supply (rated value) DC 24V - Permitted range 20.4...

More information

8V General information. 2 Order data 8V

8V General information. 2 Order data 8V 8V05.00-8V05.00- General information Modular mechanical design using plug-in modules Integrated line filter Integrated braking resistor All connections are made using plug-in connectors Integrated electronic

More information

Q.raxx A slimline RS / EC Universal Measurement System

Q.raxx A slimline RS / EC Universal Measurement System Q.raxx A107-16 slimline RS / EC Universal Measurement System The Q.raxx slimline product is based on the standardised 19 technology, one rack unit (1 U) and is designed for measurements with a high level

More information

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes Data sheet 902931 Page 1/10 JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes For processing physical measurands of the JUMO Wtrans series RS485 interface with Modbus protocol

More information

240 Series. Cryogenic Temperature Sensor Input Modules. 240 Series modules are the ideal companion to Cernox

240 Series. Cryogenic Temperature Sensor Input Modules. 240 Series modules are the ideal companion to Cernox 40 Series Cryogenic Temperature Sensor Input Modules 40 Series modules are the ideal companion to Cernox Model 40-P For smaller installations and high-speed measurements Updates readings as fast as ms

More information

Controller for the Implementation of a Central or Decentralized Electrohydraulic System

Controller for the Implementation of a Central or Decentralized Electrohydraulic System EFX 1624m Electronic Controller Programmed with Eaton CONTROL F(x) Software to IEC 61131-3 Standard 2nd CAN interface for gateway function according to SAE J1939 Supply voltage 10...32V DC Technical Data

More information

SMSTRB. Data Sheet. Strain SMART Module. Special Features. Block Diagram. B en

SMSTRB. Data Sheet. Strain SMART Module. Special Features. Block Diagram. B en SMSTRB Strain SMART Module Data Sheet Special Features - Conditions and amplifies output to a high level signal for use with the SoMat EHLS or ELHLS - Strain gage conditioning with support for 1/4-, 1/2-

More information

imc CANSAS-L-HCI8. High isolated module for the capture of temperature, voltage, current (20 ma) and resistance

imc CANSAS-L-HCI8. High isolated module for the capture of temperature, voltage, current (20 ma) and resistance Data Sheet Version 1.9 imc CANSAS-L-HCI8 High isolated module for the capture of temperature, voltage, current (20 ma) and resistance The imc CANSAS module (CANSAS-L-HCI8) enable measurement of low voltage

More information

AC Servo Amplifier SANMOTION R Series ADVANCED MODEL with Built-in EtherCAT Interface

AC Servo Amplifier SANMOTION R Series ADVANCED MODEL with Built-in EtherCAT Interface New Products Introduction AC Servo Amplifier SANMOTION R Series ADVANCED MODEL with Built-in EtherCAT Interface Tsuyoshi Kobayashi Naohiro Itoh Noriaki Kasuga Daisuke Naitoh Keisuke Ishizaki Yasuo Nakamura

More information

Trip amplifier, 1 channel

Trip amplifier, 1 channel Trip amplifier, channel Features I II III + + P I out I U out 4 Relay overrange Relay overrange Relay overrange ç 4...0 ma IM4-4-SRi: è 0...0 ma IV + + + > 50 kw 5 6 7 8 9»8 V < 5 ma 50 W Pwr GN/RD 4 5

More information

GSV-2MSD-DI IP43. Highlights

GSV-2MSD-DI IP43. Highlights GSV-2MSD-DI IP43 Highlights Data logger with SD-card slot USB-interface for strain gauge quarter, half and full bridges 0...10V, potentiometric 24 bit resolution 6 sensor configurations recallable battery

More information

Ultra flat POSICHRON position sensor. Current Resolution

Ultra flat POSICHRON position sensor. Current Resolution Ultra flat Profile Housing with analog Ultra flat POSICHRON position sensor Only 8 mm high and 28 mm wide Protection class up to IP67 Measurement range 0... 100 to 0... 5750 mm Absolute position measurement

More information

PHOENIX CONTACT - 03/2007

PHOENIX CONTACT - 03/2007 Inline Function Terminal for Pulse Width Modulation and Frequency Modulation N AUTOMATIONWORX Data Sheet 6920_en_01 1 Description PHOENIX CONTACT - 03/2007 $ ' ) The terminal is designed for use within

More information

EBRG. Data Sheet. edaq Bridge Layer. Special Features. Block Diagram. B en

EBRG. Data Sheet. edaq Bridge Layer. Special Features. Block Diagram. B en EBRG edaq Bridge Layer Data Sheet Special Features - 16 simultaneously-sampled, low-level differential analog inputs from ±0.000625 to ±10 V - 96 automatic gain states ensuring use of the fullest possible

More information

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

CPU 314C-2 PTP. Function

CPU 314C-2 PTP. Function CPU 314C-2 PTP Function Password protection; a password concept protects the user program from unauthorized access. Block encryption; the functions (FCs) and function blocks (FBs) can be stored in the

More information

SCHMIDT Flow Sensor SS SS FB

SCHMIDT Flow Sensor SS SS FB Product description Flow sensor with integrated microcontroller transducer for the measurement of air-flow velocity and for the determination of the flow rate and flow volume. The aerodynamically styled

More information

CoMo Injection/CoMo Injection Basic

CoMo Injection/CoMo Injection Basic Electronics & Software CoMo Injection/CoMo Injection Basic Zero-Defect Production during Injection Molding thanks to Process Monitoring Type 2869B CoMo Injection is a production optimization, control and

More information

LASER. Analog Laser Displacement Transducer. LAM Series. Key-Features: Content:

LASER. Analog Laser Displacement Transducer. LAM Series. Key-Features: Content: LASER Analog Laser Displacement Transducer LAM Series Key-Features: Content: Overview, Measuring Principle...2 Installation Instructions...3 Technical Data...4 Technical Drawings.7 Electrical Connection...9

More information

Highlights Very compact EtherCAT I/O system in IP 20 for plug-in into a circuit board (signal distribution board)

Highlights Very compact EtherCAT I/O system in IP 20 for plug-in into a circuit board (signal distribution board) 550. Highlights Very compact EtherCAT I/O system in IP 20 for plug-in into a circuit board (signal distribution board). Optimised for high-volume production Application-specific connector interface EtherCAT

More information

Q.raxx A slimline RS / EC Multi Channel System for Thermocouples

Q.raxx A slimline RS / EC Multi Channel System for Thermocouples The Q.raxx slimline product is based on the standardized 19 technology, one rack unit (1 U) and is designed for measurements with a high level of flexibility, reliability and accuracy in the field of stationary

More information