MX1615B R. Data Sheet. Ultra-rugged Bridge Amplifier

Size: px
Start display at page:

Download "MX1615B R. Data Sheet. Ultra-rugged Bridge Amplifier"

Transcription

1 MX1615B R Ultra-rugged Bridge Amplifier Data Sheet Special features 16 individually configurable inputs Connection of strain gages in quarter-, half- or full-bridge Bridge excitation: DC or carrier frequency (CF) Internal shunt calibration resistors, software controlled Connection of electrical voltage (60 V), PT100, Resistor, Potentiometric transducer Sample rate up to 20 ksamples/s per channel, active lowpass filter TEDS support Use in harsh environments (shock, vibration, temperature, dew point) Block diagram Digital platform IEEE15888v2 Ethernet Connector sockets (ODU) Connectors Signal Bridge excitation TEDS A/D Electrically isolated (PTP) IEEE1394b FireWire (Power) IEEE1394b FireWire (Power) Supply voltage

2 Specifications MX1615B R General specifications Inputs Number 16, electrically isolated to supply voltage Supported transducer technologies Strain gages in full-, half- or quarter-bridge configuration. Selectable bridge excitation voltage : DC voltage or carrier frequency (AC/CF, 1,200 ) SG-quarter bridges SG-half bridges SG-full bridges Three wire and four wire five wire six wire Resistor, Resistance thermometer (PT100), connection in four-wire configuration Potentiometric transducers Voltage 60 V A/D converter 24 Bit Delta Sigma Converter Sample rates S/s Decimal: ,000 HBM Classic: ,200 Active low-pass filter Bessel, Butterworth, Linear Phase, Filter off Transducer identification (TEDS, IEEE ) max. distance of the TEDS module m 100 Transducer connection ODU MINI-SNAP, 14 pins Supply voltage range (DC) V (24 V nominal (rated) voltage) Supply voltage interruption max. 5 ms at 24 V Power consumption W < 12 Ethernet (data link) 10Base-T / 100Base-TX Protocol TCP/IP Connector ODU MINI-SNAP, 8 pins Max. cable length to module m 100 Synchronization options FireWire IEEE1394b Ethernet PTPv2 IEEE1588 Ethernet NTP IEEE1394b FireWire (optional supply voltage) Max. current from module to module Connector FireWire based synchronization Ethernet based Precision Time Protocol Ethernet based Network Time Protocol IEEE 1394b (HBM modules only) A 1.5 ODU MINI-SNAP, 8 pins Max. cable length between the nodes m 5 Max. number of modules connected in series (daisy chain) 12 (=11 Hops 1) ) Nominal (rated) temperature range C [ F] [ ] dew point resistant Storage temperature range C [ F] [ ] Relative humidity % Protection class III Degree of protection (dust, humidity/water) IP65/IP67 per EN EMC requirements Mechanical test Vibration Acceleration Duration Frequency Shock Acceleration Pulse duration Number of impacts m/s 2 min m/s 2 ms CE conformity test per EN accord. MIL STD202G, Method 204D, Test condition C bis 2,000 accord. MIL STD202G, Method 213B, Test condition B Operating altidude, max. m 5,000 Max. input voltage at transducer socket, transient free Pin 3 to Pin 4 Pin 1, 2, 7, 8, 11, 12 or 14 to Pin 13 V V ,5 Dimensions, horizontal (W x H x D) mm 80 x 205 x 140 Weight, approx. g /pound 2,300 / ) Hops: Transition from module to module or signal conditioning / distribution via IEEE1394b FireWire (hub, backplane) HBM 2

3 Specifications MX1615B R (Continued) Strain gage full and half bridge, bridge excitation AC / carrier frequency Accuracy class ) Carrier frequency (square) 1,200 2 Bridge excitation voltage (effective) V 1; 2.5; 5 ( 5 %) Permissible cable length between module and transducer m < 100 Measuring ranges at 5 V excitation at 2.5 V excitation at 1 V excitation Control signals (Shunt) Shunt resistance (for pos. signal) Shunt resistance (for neg. signal) ±4 ±8 ± ± 0.1 %, to positive excitation 100 ± 0.1 %, to negative excitation Max. Bandwidth (filter off, 3 ) 400 Transducer impedance at 5 V excitation at 2.5 V excitation at 1 V excitation Noise at 25 C and 5 V excitation (peak to peak) with filter 1 Bessel with filter 10 Bessel with filter 100 Bessel , , ,000 < 0.2 < 0.5 < 1.5 Linearity error % < 0.02 of full scale Zero drift (Full bridge with 5 V excitation) % / 10 < ) of full scale Full-scale drift (5 V excitation) % / 10 < 0.05 of measurement value 1) 0.1 with half bridge Strain gage full and half bridge, bridge excitation DC Accuracy class 0.1 1) Bridge excitation voltage (DC) < 1; 2.5; 5; ( 5 %) Permissible cable length between module and transducer m < 100 Measuring ranges at 5 V excitation at 2.5 V excitation at 1 V excitation Control signals (Shunt) Shunt resistance (for pos. signal) Shunt resistance (for neg. signal) ±4 ±8 ± ± 0.1 %, to positive excitation 100 ± 0.1 %, to negative excitation Max. Bandwidth (filter off, 3 ) 3,000 Transducer impedance at 5 V excitation at 2.5 V excitation at 1 V excitation Noise at 25 C and 5 V excitation (peak to peak) with filter 1 Bessel with filter 10 Bessel with filter 100 Bessel with filter 1 k Bessel ,000 2) ,000 2) ,000 2) < 0.2 < 0.4 < 1 < 3 Linearity error % < 0.02 of full scale Zero drift (Full bridge with 5 V excitation) % / 10 < 0.1 1) of full scale Full-scale drift (5 V excitation) % / 10 < 0.05 of measurement value 1) with 10 V/m electromagnetic field strength (EN ): 0.2 2) Range can be extended up to 5, in this case: up to 0.3 % absolute zero deviation 3 HBM

4 Specifications MX1615B R (Continued) Single strain gage quarter bridge in 4-wire circuit, bridge excitation AC / carrier frequency Accuracy class 0.1 Carrier frequency (square) 1,200 2 Bridge excitation voltage (effective) V 0.5; 1; 2.5; 5 ( 5 %) Permissible cable length between module and transducer m < 100 Measuring ranges at 5 V excitation (only at 350 Ohm strain gage) at 2.5 V excitation at 1 V excitation at 0.5 V excitation Control signals (Shunt) Shunt resistance (via completion resistor, for pos. signal) Shunt resistance (via external strain gage, for neg. signal) ±4 ±8 ±20 ± ± 0.1 % 100 ± 0.1 % Max. Bandwidth (filter off, 3 ) 400 Internal completion resistors 120 and 350 Noise 1) at 25 C and 5 V excitation (peak to peak) with filter 1 Bessel with filter 10 Bessel with filter 100 Bessel < 0.3 < 0.6 < 1.5 Linearity error 1) % < 0.05 of full scale Zero drift 1) (5 V excitation) % / 10 < 0.1 of full scale Full-scale 1) drift (5 V excitation) % / 10 < 0.05 of measurement value 1) With 350 ohm resistor Single strain gage quarter bridge in 4-wire or 3-wire circuit, bridge excitation DC Accuracy class 0.1 1) Bridge excitation voltage (DC) V 0.5; 1; 2.5; 5 ( 5 %) Permissible cable length between module and transducer m < 100 Measuring ranges at 5 V excitation (only at 350 Ohm strain gage) at 2.5 V excitation at 1 V excitation at 0.5 V excitation Control signals (Shunt) Shunt resistance (via completion resistor, for pos. signal) Shunt resistance (via external strain gage, for neg. signal) ±4 ±8 ±20 ± ± 0.1 % 100 ± 0.1 % Max. Bandwidth (filter off, 3 ) 3,000 Internal completion resistors 120 and 350 Noise 2) at 25 C and 5 V excitation (peak to peak) with filter 1 Bessel with filter 10 Bessel with filter 100 Bessel with filter 1 k Bessel Linearity error 2) % < 0.05 of full scale Zero drift 2) (5 V excitation) % / 10 <0.1 of full scale Full-scale 2) drift (5 V excitation) % / 10 < 0.05 of measurement value 1) with 10 V/m electromagnetic field strength (EN ): 0.2 The accuracy class does not take into account measurement errors resulting from asymmetrical cable resistances when using a three-wire circuit. 2) With 350 ohm resistor and connection using a four-wire circuit. < 0.4 < 0.6 < 1.5 < 3 HBM 4

5 Specifications MX1615B R (Continued) Potentiometric transducer Accuracy class 0.1 Excitation voltage (DC) V 1 ( 5 %) Permissible cable length between module and transducer m < 100 Measuring range 500 Max. Bandwidth (filter off, 3 ) 3,000 Transducer impedance ,000 Noise at 25 C (peak to peak) with filter 1 Bessel with filter 10 Bessel with filter 100 Bessel with filter 1 k Bessel Linearity error % < 0.05 of full scale Zero drift % / 10 < 0.1 of full scale Full-scale drift % / 10 < 0.1 of measurement value < 2 < 4 < 10 < V (DC) electrical voltage Accuracy class 0.05 Permissible cable length between module and transducer m < 100 Measuring range V 60 Max. Bandwidth (filter off, 3 ) 3,000 Internal resistance of the connected voltage source < 500 Input impedance M > 2 Noise at 25 C (peak to peak) at 1 Bessel filter at 10 Bessel filter at 100 Bessel filter at 1 k Bessel filter V V V V ,000 Linearity error % < 0.02 of full scale Common-mode rejection at DC common-mode at 50 common-mode, typically Max. common-mode voltage to housing and supply ground V ± 60 Zero drift % / 10 < 0.03 of full scale Full-scale drift % / 10 < 0.03 of measurement value > HBM

6 Specifications MX1615B R (Continued) Ohmic resistance up to 1,000 ohms Accuracy class 0.1 Transducers that can be connected PTC, NTC, TY, TT-3, resistances in general Permissible cable length between module and transducer m < 100 Measuring range ,000 1) Excitation current ma Max. Bandwidth (filter off, 3 ) 3,000 Noise at 25 C (peak to peak) with filter 1 Bessel with filter 10 Bessel with filter 100 Bessel with filter 1 k Bessel Linearity error % < 0.05 of full scale Zero drift %/10 < 0.02 of full scale Full-scale drift % / 10 < 0.1 of measurement value 1) Measuring range can be extended up to 5, in this case: accuracy class 2 < 0.1 < 0.2 < 0.5 < 1.5 Resistance thermometer (PT100) Accuracy class 0.1 Permissible cable length between module and transducer m < 100 Linearization range o C [ o F] [ ,558.4] Excitation current ma Max. Bandwidth (filter off, 3 ) 3,000 Noise at 25 C (peak to peak) with filter 1 Bessel with filter 10 Bessel with filter 100 Bessel with filter 1 k Bessel < 0.02 < 0.04 < 0.1 < 0.3 Linearity error < 0.3 Zero drift / 10 < 0.2 Full-scale drift / 10 < 0.5 HBM 6

7 Decimal sample rates and digital low pass filter, type Bessel 4 th order Type -1 () -3 () -20 () Bessel Phase delay *) (ms) Rise time (ms) Overshoot (%) Rate () 1,203 2,000 3, , ,000 2, , , , , , , , , , , , , ,660 1, , ,300 3, ,620 7, ,500 17, ,000 35, *) The analog-to-digital converter s delay time is 128 s for all data rates and has not been accounted for in the Phase delay column! Decimal sample rates : amplitude response Bessel filter ,001 0,01 0, k 1 k 7 HBM

8 Decimal sample rates and digital low pass filter, type Butterworth 4 th order Typ -1 () -3 () -20 () Butterworth Phase delay *) (ms) Rise time (ms) Overshoot (%) Rate () 2,612 3, , ,000 1,703 2, , , , , , , , , , , , , , ,250 1, , ,490 3, , ,980 7, , ,500 19, , ,900 38, *) The analog-to-digital converter s delay time is 128 s for all data rates and has not been accounted for in the Phase delay column! Decimal sample rates : amplitude response Butterworth filter ,001 0,01 0, k k 3 k HBM 8

9 Decimal sample rates : active low pass filter MX1615B R, Linear Phase (FIR) Type Linear Phase Start of Roll off -3 () -20 () Phase delay *) (ms) Rise time (ms) Overshoot (%) Rate () 3, , , , , , , , *) The analog-to-digital converter s delay time is 128 s for all data rates and has not been accounted for in the Phase delay column! Decimal sample rates : Amplitude response of MX1615B R, Linear Phase (FIR) HBM

10 Decimal sample rates : active low pass filter MX1615B R, Butterworth filter (FIR) Type -1 () -3 () -20 () Butterworth Phase delay *) (ms) Rise time (ms) Overshoot (%) Rate () 1,384 1,500 1, , , , , , *) The analog-to-digital converter s delay time is 128 s for all data rates and has not been accounted for in the Phase delay column! Decimal sample rates : Amplitude response of MX1615B R, Butterworth filter (FIR) HBM 10

11 Classic HBM sample rates and digital low pass filter, type Bessel *) 4 th order Type -1 () -3 () -20 () Phase delay (ms) **) Rise time (ms) Overshoot (%) Date rate () 1,000 1,575 3, , , , , , , , , , , , , ,950 2, ,860 4, ,800 10, ,500 21, *) Bessel ( 1, with CF supply only valid for f g 100 ) **) The analog-to-digital converter s delay time is 128 s for all data rates and has not been accounted for in the Phase delay column! Bessel Classic HBM sample rates : amplitude response Bessel filter k HBM

12 Classic HBM sample rates and digital low pass filter, type Butterworth *) 4 th order Type -1 () -3 () -20 () Phase delay (ms) **) Rise time (ms) Overshoot (%) Date rate () 2,000 3,053 5, ,200 1,000 1,170 2, , , , , , , , , ,900 1, ,770 3, ,490 6, ,900 16, ,700 32, *) Butterworth ( 1, with CF supply only valid for f g 100 ) Butterworth **) The analog-to-digital converter s delay time is 128 s for all data rates and has not been accounted for in the Phase delay column! Classic HBM sample rates : amplitude response Butterworth filter k k HBM 12

13 Classic HBM sample rates : amplitude response Butterworth filter HBM

14 Hottinger Baldwin Messtechnik GmbH. Subject to modifications. All product descriptions are for general information only. They are not to be understood as a guarantee of quality or durability. Hottinger Baldwin Messtechnik GmbH Im Tiefen See Darmstadt Germany Tel Fax: info@hbm.com measure and predict with confidence B en

MX1615B-R. Ultra-rugged Bridge Amplifier. Special features. Data sheet. Block diagram

MX1615B-R. Ultra-rugged Bridge Amplifier. Special features. Data sheet. Block diagram MX1615B-R Ultra-rugged Bridge Amplifier Special features - 16 individually configurable inputs - Connection of strain gages in half-, full- or quarter-bridge (120 Ohm or 350 Ohm) - Bridge excitation: DC

More information

MX1601B R. Data Sheet. Ultra-rugged Standard Amplifier

MX1601B R. Data Sheet. Ultra-rugged Standard Amplifier MX1601B R Ultra-rugged Standard Amplifier Data Sheet Special features 16 individually configurable inputs (electrically isolated) Support of 60 V, 10 V, 100 mv, 20 ma or IEPE on all channels Sample rate:

More information

MX1601B-R. Ultra rugged Standard Amplifier. Data sheet. Special features. Block diagram

MX1601B-R. Ultra rugged Standard Amplifier. Data sheet. Special features. Block diagram MX1601B-R Ultra rugged Standard Amplifier Special features - 16 individually configurable inputs (electrically isolated) - Support of 60 V, 10 V, 100 mv, 20 ma or IEPE on all channels - Sample rate: up

More information

MX840B R. Data sheet. Ultra-rugged universal amplifier CAN. Special features. Block diagram. B en

MX840B R. Data sheet. Ultra-rugged universal amplifier CAN. Special features. Block diagram. B en MX840B R Ultra-rugged universal amplifier Data sheet Special features 8 individually configurable inputs (electrically isolated) Connection of more than 16 technologies per channel Sampling rates of up

More information

MX460B-R. Rugged pulse and frequency measuring module. Data sheet. Special features. Block diagram

MX460B-R. Rugged pulse and frequency measuring module. Data sheet. Special features. Block diagram MX460B-R Rugged pulse and frequency measuring module Special features - Four individually configurable inputs (electrically isolated) - Measure any kind of digital signals up to 1 Mhz for measurement of

More information

MX1615. Data sheet. Bridge/strain gauge amplifier

MX1615. Data sheet. Bridge/strain gauge amplifier MX1615 Bridge/strain gauge amplifier Data sheet Special features 16 individually configurable inputs Connection of strain gauges in quarter-, half- and full-bridge Bridge excitation : DC or carrier frequency

More information

MX1615B. Data sheet. Bridge/strain gauge amplifier

MX1615B. Data sheet. Bridge/strain gauge amplifier MX1615B Bridge/strain gauge amplifier Special features 16 individually configurable inputs Connection of strain gauges in quarter-, half- and full-bridge Bridge excitation : DC or carrier frequency Internal

More information

MX1616B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

MX1616B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram MX1616B Strain gauge bridge amplifier Special features - 16 individually configurable inputs - Connection of strain gauges in full-, halfand quarter-bridge (350 or 1,000 Ohm) - Bridge excitation : DC or

More information

MX1615B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

MX1615B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram MX1615B Strain gauge bridge amplifier Special features - 16 individually configurable inputs - Connection of strain gauges in full-, half-, or quarter-bridge (120 or 350 Ohm) - Bridge excitation : DC or

More information

MX1601B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

MX1601B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en MX1601B Universal amplifier Data Sheet Special features 16 individually configurable inputs (electrically isolated) Connection of of standard signals (60, 10, 100 m, 20 ma, IEPE) Individual data rates

More information

MX440A. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

MX440A. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en MX440A Universal amplifier Data Sheet Special features 4 individually configurable inputs (electrically isolated) Connection of more than 12 transducers technologies Data rate: up to 19,200 Hz 24 bit A/D

More information

MX410B. Highly dynamic universal amplifier. Data sheet. Special features. Block diagram

MX410B. Highly dynamic universal amplifier. Data sheet. Special features. Block diagram MX410B Highly dynamic universal amplifier Special features - 4 individually configurable inputs (electrically isolated) - Connection of more than 5 transducer technologies - Individual sample rates up

More information

MX440B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

MX440B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en MX440B Universal amplifier Data Sheet Special features 4 individually configurable inputs (electrically isolated) Connection of more than 16 different transducer types Individual data rates up to 40kHz

More information

MX840B. Data Sheet. Universal amplifier CAN. Special features. Block diagram. B en

MX840B. Data Sheet. Universal amplifier CAN. Special features. Block diagram. B en MX840B Universal amplifier Data Sheet Special features 8 individually configurable measurement channels (electrically isolated) Connection of more than 16 transducer technologies per channel Individual

More information

MX460B. Data sheet. Pulse and Frequency Measurement Module. Special features. Block diagram. B en

MX460B. Data sheet. Pulse and Frequency Measurement Module. Special features. Block diagram. B en MX460B Pulse and Frequency Measurement Module Data sheet Special features 4 individually configurable inputs (electrically isolated) Measure any kind of digital pulses up to 1 Mhz for measurement of speed,

More information

CPU. BM40, BM40PB, BM40IE Industrial amplifier. Special features. Data sheet. Block diagram

CPU. BM40, BM40PB, BM40IE Industrial amplifier. Special features. Data sheet. Block diagram Industrial amplifier Special features - Freely configurable measurement channel with TEDS channel parameterization - Connection of 7 transducer technologies with a 19.2 KHz sample rate - Accuracy class

More information

Inductive Standard Displacement Transducers

Inductive Standard Displacement Transducers WA Inductive Standard Displacement Transducers Special features - Available as displacement probe or with detachable plunger - Good thermal stability in the event of temperature gradients - Space saving,

More information

T22. Torque transducer. Special features. Data sheet

T22. Torque transducer. Special features. Data sheet T22 Torque transducer Special features - Nominal (rated) torques 0.5 Nm, 1 Nm, 2 Nm, 5 Nm, Nm, Nm, 50 Nm, 0 Nm, 0 Nm, 500 Nm and 1 knm - Nominal (rated) rotational speed up to 000 rpm (depending on measuring

More information

CANHEAD. Data Sheet. Special features. Distributed measurement acquisition. B en

CANHEAD. Data Sheet. Special features. Distributed measurement acquisition. B en CANHEAD Data Sheet Special features 10channel amplifier modules for installation close to measuring points Measured data transmission to communication master via field bus Base modules for individual SGs,

More information

T40FH. Torque flange. Special features. Data sheet

T40FH. Torque flange. Special features. Data sheet T40FH Torque flange Special features - Nominal (rated) torques: 100kNm, 125kNm, 150kNm, 200kNm, 250kNm, 300kNm - Nominal (rated) rotational speed of 2000 rpm up to 3000 rpm - Compact design - Version for

More information

electronics Data Sheet Industrial Amplifier Special features Dimensions (in mm; 1 mm= inches) B en

electronics Data Sheet Industrial Amplifier Special features Dimensions (in mm; 1 mm= inches) B en C l i p electronics Industrial Amplifier Data Sheet Special features Amplifier and additional units for strain gauge full bridges and inductive half and full bridges Modules for mounting onto support rails

More information

C9C. Force Transducer. Special features. Data sheet

C9C. Force Transducer. Special features. Data sheet C9C Force Transducer Special features - Compact design compressive force transducer - Accuracy class 0.2 - Nominal (rated) forces 50 N to 50 kn - Configurable with different cable lengths, plug assembly

More information

U9C. Data sheet. Force Transducer. Special features. B en

U9C. Data sheet. Force Transducer. Special features. B en U9C Force Transducer Data sheet Special features Tensile/compressive force transducer Accuracy class 0.2 Nominal (rated) forces 50 N 50 KN Non-rusting, protection class IP67 Configurable with different

More information

Data sheet. P3 Top Class BlueLine. P3MBP BlueLine. Ultra-high pressure transducers to 15,000 bar. Special features

Data sheet. P3 Top Class BlueLine. P3MBP BlueLine. Ultra-high pressure transducers to 15,000 bar. Special features Ultra-high pressure transducers to 1,000 bar Data sheet Special features P Top Class BlueLine PMBP BlueLine - For static and dynamic pressure variance, pressure peaks and pressure fluctuations - Principle

More information

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en T40FM Torque flange Special features Data Sheet - Nominal (rated) torque: 15 kn m, 20 kn m, 25 kn m, 30 kn m, 40 kn m, 50 kn m, 60 kn m, 70 kn m and 80 kn m - Nominal (rated) rotational speed up to 8000

More information

U2B. Force Transducer. Special features. Data sheet

U2B. Force Transducer. Special features. Data sheet U2B Force Transducer Special features - Tensile/compressive force transducer - Non rusting, degree of protection IP67 - Can be configured with different cable lengths, plug fitting and TEDS on request

More information

T40B. Torque Flange. Special features. Data sheet. Overall concept

T40B. Torque Flange. Special features. Data sheet. Overall concept T40B Torque Flange Special features - Nominal (rated) torques 50 N m, 0 N m, 200 N m, 500 N m, 1 kn m, 2 kn m, 3 kn m, 5 kn m and kn m - Nominal rated rotational speed up to 24000 rpm (depending on nominal

More information

SMSTRB. Data Sheet. Strain SMART Module. Special Features. Block Diagram. B en

SMSTRB. Data Sheet. Strain SMART Module. Special Features. Block Diagram. B en SMSTRB Strain SMART Module Data Sheet Special Features - Conditions and amplifies output to a high level signal for use with the SoMat EHLS or ELHLS - Strain gage conditioning with support for 1/4-, 1/2-

More information

T22. Data Sheet. Torque transducer. Special features. Installation example with two bellows couplings. B en

T22. Data Sheet. Torque transducer. Special features. Installation example with two bellows couplings. B en T22 Torque transducer Data Sheet Special features - Nominal (rated) torques N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m, 00 N m and 1 kn m - Nominal (rated) rotational speeds of 9000 rpm to 16 000 rpm

More information

U10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch]

U10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch] U10M Force Transducer Special features - Precise and robust tensile/compressive force transducer for static and dynamic measurement tasks - High lateral force and bending moment stability, the effect of

More information

E *) F 15. H 12 h9. 5.5f7 8h6. a./f approx. 0.5mm Free stroke. Displacement. Initial stroke

E *) F 15. H 12 h9. 5.5f7 8h6. a./f approx. 0.5mm Free stroke. Displacement. Initial stroke Displacement probe Plunger WA Inductive Standard Displacement Transducers Special features Displacement probe and transducer with detachable plunger Good thermal stability in the event of temperature gradients

More information

U2B. Data sheet. Force Transducer. Special features. B en

U2B. Data sheet. Force Transducer. Special features. B en U2B Force Transducer Special features Data sheet Tensile/compressive force transducer Non-rusting, degree of protection IP67 Can be configured with different cable lengths, plug fitting and TEDS on request

More information

EBRG. Data Sheet. edaq Bridge Layer. Special Features. Block Diagram. B en

EBRG. Data Sheet. edaq Bridge Layer. Special Features. Block Diagram. B en EBRG edaq Bridge Layer Data Sheet Special Features - 16 simultaneously-sampled, low-level differential analog inputs from ±0.000625 to ±10 V - 96 automatic gain states ensuring use of the fullest possible

More information

Single point load cell

Single point load cell PW15AH Single point load cell Special features - Nominal load 10 kg... 100 kg - Stainless steel - High ratio of minimum verification interval Y - Industrial Footprint (SP4M) - Degree of Protection IP68;

More information

U15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants

U15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants U15 Force transducer Special features - Tensile/compressive force transducer - Nominal (rated) forces 2.5 kn to 2.5 MN - lass 0.5 to ISO 376 in force measurement range between 10% and 100% of the nominal

More information

T10F. Data Sheet. Torque Flange. Special features. Installation example T10F. B en

T10F. Data Sheet. Torque Flange. Special features. Installation example T10F. B en T10F Torque Flange Data Sheet Special features Extremely short design High permissible dynamic loads High permissible transverse forces and bending moments Very high torsional stiffness Contactless Selectable

More information

MGCplus. Measuring amplifier system. Special features. Data sheet

MGCplus. Measuring amplifier system. Special features. Data sheet MGCplus Measuring amplifier system - Up to 128 channels per MGCplus enclosure (256 or 512 with CANHEAD or CAN) - Sampling rates up to 19.2 ks/s per channel - Simultaneous and parallel measurement with

More information

C10. Data sheet. Force transducer. Special features. B de

C10. Data sheet. Force transducer. Special features. B de C10 Force transducer Data sheet Special features Force transducer for static and dynamic applications Made of non-rusting materials Precise (accuracy class from 0.03) Numerous options (double bridge, TEDS,

More information

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en T10FS Torque Flange Data Sheet Special features Nominal (rated) torques: 100 NVm, 200 NVm, 500 NVm, 1 knvm, 2 knvm, 3 knvm, 5 knvm, 10 knvm Nominal speed from 12,000 rpm to 24,000 rpm Low rotor weights

More information

MDEX. on customized sensors. Technical information. Torque transducer. CS-T-04-MDEX Special features

MDEX. on customized sensors. Technical information. Torque transducer. CS-T-04-MDEX Special features MDEX Torque transducer CS-T-04-MDEX Special features - Explosion proof acc. to ATEX 95 - Exx II 2 G Ex deq IIC T4 - Nominal (rates) torque of 100kNm, 130kNm and 150kNm - HBM Accuracy Class 0,1 - Digital

More information

Single point load cell

Single point load cell PW15AH Single point load cell Special features - Nominal load 10 kg... 100 kg - Stainless steel - High ratio of minimum verification interval Y - Industrial Footprint (SP4M) - Degree of Protection IP68;

More information

TB2. Torque reference transducer. Special features. Data sheet

TB2. Torque reference transducer. Special features. Data sheet T2 Torque reference transducer pecial features tandard version - ccuracy class 0.03 - ominal (rated) s 100 m, 200 m, 500 m, 1 k m, 2 k m, 3 k m, 5 k m and 10 k m - High permissible oscillation width -

More information

7600 Isolated Digitizer and Receiver

7600 Isolated Digitizer and Receiver 7600 Isolated Digitizer and Receiver Data sheet GEN series Features and Benefits - Complete single-channel isolated analog input subsystem - Rugged enclosure for use in EMI hostile environments - Shock

More information

Data Sheet. Absolute pressure transducer Nominal (rated) pressure 10 bar to 3000 bar. Special features

Data Sheet. Absolute pressure transducer Nominal (rated) pressure 10 bar to 3000 bar. Special features P3 Top Class P3MB version with fixed cable P3MBP version with plug connection TEDS: Transducer Electronic Data Sheet P3 Absolute pressure transducer Nominal (rated) pressure 10 bar to 3000 bar Special

More information

Load cell. Special features. Data sheet

Load cell. Special features. Data sheet Z6R Load cell Special features - Nominal (rated) loads: 20 kg 200 kg - Welded-on robust cover - Load cells made of rust-resistant materials - Easy to clean - Same dimensions like Z6F - Verifiable up to

More information

Multipoint measuring units UPM100 and Centipede100

Multipoint measuring units UPM100 and Centipede100 OTTINGER ALDWIN ESSTECHNIK HBM Mess- und Systemtechnik GmbH Multipoint measuring units UPM100 and Centipede100 S 33.UPM100.10 e Multipoint measuring units UPM100 and Centipede100 HBM s multipoint measurement

More information

S9M. Force Transducer. Special features. Data sheet

S9M. Force Transducer. Special features. Data sheet S9 Force Transducer Special features - Tensile/compressive force transducer - ccuracy class 0.02 - Hermetically encapsulated (IP68) - Rust-resistant materials - vailable in different cable lengths and

More information

Specifications Type WA2 WA10 WA20 WA50 WA100 WA200 WA300 WA500 Nominal displacement mm Nomi

Specifications Type WA2 WA10 WA20 WA50 WA100 WA200 WA300 WA500 Nominal displacement mm Nomi Displacement probe WA Inductive Standard Displacement Transducers Special features Data Sheet Plunger Displacement probe and transducer with detachable plunger Good thermal stability in the event of temperature

More information

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits ISOBE5600 Isolated Probe Systems - ISOBE5600 Isolation system - ISOBE5600 Transient recorder Data sheet Features and Benefits ISOBE5600 Isolation system - Cost-effective - Fiber-optic isolation - Analogue-in

More information

Operating manual. 600 Hz Measuring Amplifier ME30. A en

Operating manual. 600 Hz Measuring Amplifier ME30. A en Operating manual 600 Hz Measuring Amplifier ME30 ME30 Contents 3 Page Safety instructions............................................. 4 1 Measuring Amplifiers on Eurocards ME30.................... 8

More information

GEN series GN411. Data sheet. Bridge ISO 1 MS/s Input Card. Special features

GEN series GN411. Data sheet. Bridge ISO 1 MS/s Input Card. Special features GEN series GN411 Bridge ISO 1 MS/s Input Card Data sheet Special features - Quarter/Half/Full bridge support - Strain gauge bridge sensors - Positive and negative shunt calibration - Voltage or current

More information

100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features

100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features C16A 100/200/400 t Self-centering pendulum lead cells Special features - Self restoring function - Nominal (rated) loads: 100 t, 200t and 400t - Simple installation - Rust resistant materials, laser welded,

More information

Data Acquisition System - Universal and Distributable. Efficient, modular system concept

Data Acquisition System - Universal and Distributable. Efficient, modular system concept Data Acquisition System - Universal and Distributable Efficient, modular system concept Engineering of High-Quality Products Mobile data acquisition Typical applications: Acquiring load on mechanical components

More information

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc HSI Series Modules Selection Guide HSI Series Modules Single channel High bandwidth - for dynamic signals Isolation (all models Analog signal output (±5 V Single channel modularity For DEWETRON systems

More information

T12. Data sheet. Digital Torque Transducer. Special features. Signal flow block diagram. B en

T12. Data sheet. Digital Torque Transducer. Special features. Signal flow block diagram. B en T12 Digital Torque Transducer Data sheet Special features Nominal (rated) torques 100 N m, 200 N m, 500 N m, 1 kn m, 2 kn m, 3 kn m, 5 kn m and 10 kn m Nominal (rated) rotational speeds from 10 000 rpm

More information

Operating manual. Force transducer with strain gage measuring system C9B. A en. hvordan man bruger astrologi med tibetanske medicin

Operating manual. Force transducer with strain gage measuring system C9B. A en. hvordan man bruger astrologi med tibetanske medicin Operating manual Force transducer with strain gage measuring system C9B hvordan man bruger astrologi med tibetanske medicin C9B Contents 3 Page Safety instructions..............................................

More information

MP85A/ MP85ADP. FASTpress. Data Sheet. Special features MP85A / MP85ADP. B en

MP85A/ MP85ADP. FASTpress. Data Sheet. Special features MP85A / MP85ADP. B en MP85A/ MP85ADP FASTpress Data Sheet Special features 100% quality control of the production process Powerful algorithms for monitoring fitting, testing and press fitting processes Universal twin channel

More information

Installation Guide. English. FS62 Surface Mountable Strain Sensor

Installation Guide. English. FS62 Surface Mountable Strain Sensor Installation Guide English FS62 Surface Mountable Strain Sensor Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 D-64239 Darmstadt Tel. +49 6151 803-0 Fax +49 6151 803-9100 info@hbm.com www.hbm.com

More information

Installation Guide. English. FS62 Embedded Strain Sensor

Installation Guide. English. FS62 Embedded Strain Sensor Installation Guide English FS62 Embedded Strain Sensor Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 D-64239 Darmstadt Tel. +49 6151 803-0 Fax +49 6151 803-9100 info@hbm.com www.hbm.com HBM FiberSensing,

More information

Installation Guide. English. FS62 Composite Strain Sensor

Installation Guide. English. FS62 Composite Strain Sensor Installation Guide English FS62 Composite Strain Sensor Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 D-64239 Darmstadt Tel. +49 6151 803-0 Fax +49 6151 803-9100 info@hbm.com www.hbm.com HBM FiberSensing,

More information

Installation Guide. English. FS62 Miniature Polyimide Strain Sensor

Installation Guide. English. FS62 Miniature Polyimide Strain Sensor Installation Guide English FS62 Miniature Polyimide Strain Sensor Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 D-64239 Darmstadt Tel. +49 6151 803-0 Fax +49 6151 803-9100 info@hbm.com www.hbm.com

More information

KMT - Kraus Messtechnik GmbH

KMT - Kraus Messtechnik GmbH KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany, 08024-48737, Fax. 08024-5532 Home Page http://www.kmt-telemetry.com, Email: info@kmt-telemetry.com CTP8-Rotate 8 (4) channel telemetry

More information

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Features EX1629. High-performance Remote Strain Gage Measurement Unit. Overview. 48 programmable channels in a single unit

Features EX1629. High-performance Remote Strain Gage Measurement Unit. Overview. 48 programmable channels in a single unit Overview The VXI Technology EX1629 Remote Strain Gage simplifies stress and fatigue testing of large mechanical structures such as airframes and launch vehicles. Ethernet control allows for remote operation

More information

RSCC. Data Sheet. Load cells. Special features. Diagram of RSCC load cell. Design: 500 kg to 5 t. Design: 50 kg to 200 kg. B

RSCC. Data Sheet. Load cells. Special features. Diagram of RSCC load cell. Design: 500 kg to 5 t. Design: 50 kg to 200 kg. B RSCC Load cells Data Sheet Special features - Load cell with SG measurement system - aximum capacities: 50 kg to 5 t - Hermetically sealed (IP68) - Rust resistant materials - Legal for trade to 3000 divisions,

More information

ELDIO. Data Sheet. edaqlite Digital Input/Output Layer. Special Features. Block Diagram. B en

ELDIO. Data Sheet. edaqlite Digital Input/Output Layer. Special Features. Block Diagram. B en ELDIO edaqlite Digital Input/Output Layer Data Sheet Special Features - 8 digital inputs/outputs, 4 wide-range inputs, 6 configurable pulse counters and up to two independent vehicle bus module interfaces

More information

Installation Guide. English. FS62 Weldable Strain Sensor

Installation Guide. English. FS62 Weldable Strain Sensor Installation Guide English FS62 Weldable Strain Sensor Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 D-64239 Darmstadt Tel. +49 6151 803-0 Fax +49 6151 803-9100 info@hbm.com www.hbm.com HBM FiberSensing,

More information

EX FEATURES. Stand-alone 48-channel unit with built-in Ethernet controller. Built-in bridge completion and Excitation

EX FEATURES. Stand-alone 48-channel unit with built-in Ethernet controller. Built-in bridge completion and Excitation data sheet EX1629-001 High-performance Remote Strain Gage Measurement Unit FEATURES Stand-alone 48-channel unit with built-in Ethernet controller Built-in bridge completion and Excitation 24-bit A/D per

More information

SPIDER-80SG. General Data Acquisition Device with Strain Gage Measurement. Spider Measurement Solution

SPIDER-80SG. General Data Acquisition Device with Strain Gage Measurement. Spider Measurement Solution SPIDER-80SG General Data Acquisition Device with Strain Gage Measurement Spider Measurement Solution W W W. C R Y S TA L I N S T R U M E N T S. C O M Introducing the Spider-80SG Spider-80SG Modular Strain

More information

KMT - Kraus Messtechnik GmbH

KMT - Kraus Messtechnik GmbH KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany, 08024-48737, Fax. 08024-5532 Home Page http://www.kmt-telemetry.com, Email: info@kmt-telemetry.com User Manual CTP8-Rotate 8 (4)

More information

User Manual CTP4/8/16

User Manual CTP4/8/16 KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany, 08024-48737, Fax. 08024-5532 Home Page http://www.kmt-telemetry.com, Email: info@kmt-telemetry.com User Manual CTP4/8/16 4/8/16-channel

More information

T12. Digital Torque Transducer. Data Sheet. Special features. Block diagram signal flow. B en

T12. Digital Torque Transducer. Data Sheet. Special features. Block diagram signal flow. B en T12 Digital Torque Transducer Data Sheet Special features Nominal (rated) torques of 100 NVm, 200 NVm, 500 NVm, 1 knvm, 2 knvm, 3 knvm, 5 knvm and 10 knvm Nominal (rated) speeds from 10,000 rpm to 18,000

More information

EEPROM. Intelligent signal processing and powerful algorithms for acquiring and assessing switching points and closing actions

EEPROM. Intelligent signal processing and powerful algorithms for acquiring and assessing switching points and closing actions MP85A S MP85ADP S EASYswitch Special features 100% quality control of the checking process Powerful algorithms for acquiring and assessing switching points and closing actions Universal twin-channel amplifier

More information

MP85A/ MP85ADP. FASTpress. Data Sheet. Special features MP85A / MP85ADP. B en

MP85A/ MP85ADP. FASTpress. Data Sheet. Special features MP85A / MP85ADP. B en MP85A/ MP85ADP FASTpress Data Sheet Special features 100% quality control of the production process Powerful algorithms for monitoring fitting, testing and press-fitting processes Universal twin-channel

More information

Modular Smart Interfaces

Modular Smart Interfaces Modular Smart Interfaces Automotive Energy & Power Analysis Aerospace & Defense Transportation General Test & Measurement Modular Smart Interfaces MSI Series Modular Smart Interfaces (MSI) bring an expanded

More information

Terms and expressions for specifying torque transducers

Terms and expressions for specifying torque transducers Terms and expressions for specifying torque transducers Terms and expressions for specifying torque transducers Metrological properties of the torque measuring system Accuracy class The accuracy class

More information

Primary-standard resistance thermometry bridge Model CTR9000

Primary-standard resistance thermometry bridge Model CTR9000 Calibration technology Primary-standard resistance thermometry bridge Model CTR9000 WIKA data sheet CT 60.80 Applications High-performance AC resistance thermometry bridge for very accurate temperature

More information

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Linearized RTD Input 7B34 FEATURES Amplifies, Protects, Filters, and interfaces input voltages from a wide variety of two and three-wire platinum, copper and nickel Resistor Temperature Detectors

More information

TECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100

TECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100 TECHNICAL MANUAL SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100 Due to the nature of technology, changes are inevitable. For latest technical specifications, see our website. Copyright

More information

Telemetrie-Messtechnik Schnorrenberg

Telemetrie-Messtechnik Schnorrenberg Telemetrie-Messtechnik Schnorrenberg CTP8-Rotate 8 (4) channel telemetry for rotating applications like wheels or rotors, high signal bandwidth, 16bit, software programmable Inputs for STG, TH-K, ICP or

More information

GEN series GN413. Data sheet. Differential 25 MS/s Input Card. Special features

GEN series GN413. Data sheet. Differential 25 MS/s Input Card. Special features Differential 25 MS/s Input Card Special features - Differential 25 MS/s Input Card For fast signals, the 25 MS/s high speed digitizer board is equipped with four channels sampling at high speed. The basic

More information

SC-4/M User manual 4-channel measuring amplifier

SC-4/M User manual 4-channel measuring amplifier Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, ++49-8024-48737, Fax.++49-8024 -5532 - Germany Web: www.kmt-gmbh.com E-mail: info@kmt-gmbh.com SC-4/M User manual 4-channel measuring amplifier

More information

GEN series GN610. Data sheet. Isolated 1 kv 2 MS/s Input Card. Features and Benefits

GEN series GN610. Data sheet. Isolated 1 kv 2 MS/s Input Card. Features and Benefits GEN series GN610 Isolated 1 kv 2 MS/s Input Card Data sheet Features and Benefits - 6 analog channels - Isolated, balanced differential inputs - ± 20 mv to ± 1000 V input range - 600 V RMS CAT II isolation

More information

Torque Measurement T12 The Digital Torque Transducer

Torque Measurement T12 The Digital Torque Transducer Torque Measurement T12 The Digital Torque Transducer Photos 21.11.2014, Folie 2 Hottinger Baldwin Messtechnik GmbH Rainer Schicker Trade name smarttorque Effective until 2013-02-28 Extension by 10 years

More information

Data sheet CPU 314ST/DPM (314-6CF02)

Data sheet CPU 314ST/DPM (314-6CF02) Data sheet CPU 314ST/DPM (314-6CF02) Technical data Order no. Type 314-6CF02 CPU 314ST/DPM General information Note - Features SPEED-Bus SPEED7 technology, SPEED-Bus 8 x DI, 8 x DIO, 4 x AI, 2 x AO, 1

More information

Variable Gain 100 MHz Wideband Voltage Amplifier

Variable Gain 100 MHz Wideband Voltage Amplifier Features 10 to 60 db, Switchable in 10 db Steps Bandwidth DC... 100 MHz, Switchable to 10 MHz Built-In Temperature Compensation for Low Drift of 0.6 µv/k 2.5 nv/ Hz Input Noise Switchable AC/DC-Coupling

More information

CMC 256plus - protection relay test set and universal calibrator

CMC 256plus - protection relay test set and universal calibrator Technical Data - protection relay test set and universal calibrator The is the universal solution for testing old and new generation relays and calibrating all kinds of meters, PQ devices and transducers.

More information

Analog Isolation Amplifiers

Analog Isolation Amplifiers Isolation Amplifiers Analog Isolation Amplifiers HSI/DAQ Series Modules DEWETRON high precision signal conditioning amplifiers are available for almost any sensor to measure Voltage Current Pressure Temperature

More information

Specifications. Measuring Amplifier System. MGCplus. B en

Specifications. Measuring Amplifier System. MGCplus. B en Specifications Measuring Amplifier System MGCplus System devices Mains supply NT030 Supply voltage Max. power consumption Input frequency Start-up current V AC W A 85 264 170 40 65

More information

Model 140 Inline Amplifier

Model 140 Inline Amplifier Model 140 Inline Amplifier Low Noise Inline Amplifier Small Rugged Package Includes Auto-Zero Function The Model 140 is a remote in-line DC amplifier designed to be used with bridgetype mv output transducers.

More information

SWT 3000 Teleprotection technical data siemens.com

SWT 3000 Teleprotection technical data siemens.com Power network telecommunication SWT 3000 Teleprotection technical data siemens.com Sustainable success for high-voltage power networks The SWT 3000 Teleprotection system has been the first choice for reliable

More information

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface EPAD & CPAD Modules Automotive Energy & Power Analysis Aerospace & Defense Transportation General Test & Measurement EPAD2/CPAD2/CPAD3 Modules Modules with CAN or RS-485 The EPAD2 and CPAD2/CPAD3 series

More information

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise! Overview NEW dual ADC Overview Let`s get! The new hardware generation makes your measurement more precise! Dual core Input from Dewesoft This new technology solves the often faced problem that the signal

More information

Calibration and Testing

Calibration and Testing GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Features System Sources Measurement chain Strain gauge bridges Current signals

More information

MT32 Telemetry. KMT - Kraus Messtechnik GmbH. Multi channel telemetry system for rotating application. Powering (rotor) by battery or inductive

MT32 Telemetry. KMT - Kraus Messtechnik GmbH. Multi channel telemetry system for rotating application. Powering (rotor) by battery or inductive KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany, 08024-48737, Fax. 08024-5532 Home Page http://www.kmt-telemetry.com, Email: info@kmt-telemetry.com MT32 Telemetry Multi channel telemetry

More information

Series GLET Accessory for dataloggers series GL in modular enclosure

Series GLET Accessory for dataloggers series GL in modular enclosure PRESSURE LOAD TORQUE POSITION ROTARY ANGLE TILT ACCELERATION VIBRATION RATE SIGNAL CONDITIONER DATALOGGER Series GLET Accessory for dataloggers series GL in modular enclosure Models: GLET-IU-BNC-BA4 passive,

More information

Cold curing adhesive K-X280

Cold curing adhesive K-X280 Instructions for use English Cold curing adhesive K-X280 A4048-1.0 en English 1 Safety instructions... 3 2 General information... 3 2.1 Scope of delivery for K-X280... 3 2.2 Accessories required for installation...

More information

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface EPAD & CPAD Modules EPAD2/CPAD2/CPAD3 Modules Modules with CAN or RS-485 The EPAD2 and CPAD2/CPAD3 series are multichannel modules and combine analog signal conditioning and A/D converter in an extremely

More information

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0 Digibar II: PE00, PE50 Digital pressure gage Special features Data Sheet PE00 PE50 Operated as manometer with battery operation and Operated as pressure measurement transmitter with 420 current output,

More information

The new dimension in torque measurement

The new dimension in torque measurement Digital torque measurement system The new dimension in torque measurement T12 The digital measurement system Torque Rotational speed Power smarttorque T12 The complete torque in a single transducer SIEMENS

More information