Printview: 4-channel analog input module; 4-20 ma; Single-ended - Item No.:
|
|
- Brianna Turner
- 5 years ago
- Views:
Transcription
1 Printview: 4-channel analog input module; 4-20 ma; Single-ended - Item No: channel analog input module; 4-20 ma; Single-ended Item No: channel analog input module; 4-20 ma; Single-ended Marking Business data Supplier WAGO Item no 70-4 EAN Content Order amount Customer item number Notes The analog input module processes signals of a standard magnitude 4 20mAThe input signal is electrically isolated and is transmitted with a resolution of 2 bitsthe internal system supply powers the modulethe input channels of the module have one common ground potential Technical data Miscellaneous Color Conformity marking light gray CE Number of inputs 4 Power supply Isolation Current consumption (internal) [ma] Input voltage (max) Signal current via system voltage DC/DC 00 V system/supply 6 [ma] 32V 4-20mA
2 Printview: 4-channel analog input module; 4-20 ma; Single-ended - Item No: 70-4 Technical data Input resistance < 00 / 20mA Resolution 2 bits Conversion time (typ) [ms] 0 [ms] Measuring error (2 C) < ± 02 % of the full scale value Temperature coefficient < ± 00 % / K of the full scale value Bit width 4 x 6 bits data 4 x 8 bits control/status (optional) Degree of protection IP20 Connection technology () CAGE CLAMP Cross section from () [mm²] 008 [mm²] Cross section up to () [mm²] 2 [mm²] Cross section from () [AWG] 28 [AWG] Cross section up to () [AWG] 4 [AWG] Stripped length from () [mm] 8 [mm] Stripped length up to () [mm] 9 [mm] Stripped length () [in] 033 [in] Fire load [MJ] 234 [MJ] Weight [g] [g] Width [mm] 2 [mm] Width [in] 0472 [in] Height [mm] 64 [mm] Height [in] 22 [in] Length [mm] 00 [mm] Length [in] 3937 [in] Storage temperature -2 C +8 C Relative air humidity (no condensation) [%] 9 [%] Type of mounting DIN 3 rail Operating temperature 0 C + C EMC: marine applications - emission of interference acc to Germanischer Lloyd (2003) EMC: marine applications - immunity to interference acc to Germanischer Lloyd (2003) EMC: CE - emission of interference acc to EN (2007) EMC: CE - immunity to interference acc to EN (200) Shock resistance acc to IEC Vibration resistance acc to IEC
3 Printview: 4-channel analog input module; 4-20 ma; Single-ended - Item No: 70-4 Approbation Item No Registration Registration no Voltage [V] Current [A] Cross section [mm², AWG] 70-4 ABS 03-HG374860/3- PDA 70-4 ABS 0-HN77034-X 70-4 BSH Bescheinigung Nr BV 343/C0 BV 70-4 DNV A GL HH 70-4 IECEx IECEx PTB / KR HMB0880- AC LR 02/20026 (E4) 70-4 NK TA276M 70-4 Rina ELE3422XG 70-4 UL 08 ATEX 428 X 70-4 UL E799 Sec 70-4 UL E98726 Sec Accessories 3
4 Printview: 4-channel analog input module; 4-20 ma; Single-ended - Item No: 70-4 Accessories Carrier rail Item no Description Pack unit (Sub Pack) 20-2 Steel carrier rail; 3 x 7 mm; mm thick; 2 m long; slotted; according to en 607; "Hole width 2 mm 20-3 Steel carrier rail; 3 x 7 mm; mm thick; 2 m long; unslotted; according to en Steel carrier rail; 3 x mm; mm thick; 2 m long; unslotted; according to en Steel carrier rail; 3 x 7 mm; mm thick; 2 m long; slotted; according to en 607; "Hole width 8 mm 20-8 Steel carrier rail; 3 x mm; 23 mm thick; 2 m long; unslotted; according to en Aluminum carrier rail; 3 x 82 mm; 6 mm thick; 2 m long; unslotted; according to en Steel carrier rail; 3 x mm; mm thick; 2 m long; slotted; according to en Copper carrier rail; 3 x mm; 23 mm thick; 2 m long; unslotted; according to en Steel carrier rail; 3 x 7 mm; mm thick; 2 m long; slotted; galvanized; according to EN Steel carrier rail; 3 x 7 mm; mm thick; 2 m long; unslotted; galvanized; according to EN Steel carrier rail; 3 x mm; mm thick; 2 m long; unslotted; galvanized; ähnlich EN Steel carrier rail; 3 x mm; mm thick; 2 m long; slotted; galvanized; ähnlich EN 607 4
5 Printview: 4-channel analog input module; 4-20 ma; Single-ended - Item No: 70-4 Accessories Marking accessories Item no Description Pack unit (Sub Pack) Mini-WSB Inline; plain;,700 Mini-WSB markers ( mm) on roll; stretchable - 2 mm Miniature WSB quick marking system; plain; Marker width mm; 0 strips with 0 markers 248-0/ Miniature WSB quick marking system; plain; Marker width mm; 0 strips with 0 markers 248-0/ Miniature WSB quick marking system; plain; Marker width mm; 0 strips with 0 markers 248-0/ Miniature WSB quick marking system; plain; Marker width mm; 0 strips with 0 markers 248-0/ Miniature WSB quick marking system; plain; Marker width mm; 0 strips with 0 markers 248-0/ Miniature WSB quick marking system; plain; Marker width mm; 0 strips with 0 markers 248-0/ Miniature WSB quick marking system; plain; Marker width mm; 0 strips with 0 markers 248-0/ Miniature WSB quick marking system; plain; Marker width mm; 0 strips with 0 markers 248-0/ Miniature WSB quick marking system; plain; Marker width mm; 0 strips with 0 markers Markers for group marker carrier; DIN A4 sheet (60 markers) /73 Series marker carrier 0
6 Printview: 4-channel analog input module; 4-20 ma; Single-ended - Item No: 70-4 Accessories General accessory Item no Description Pack unit (Sub Pack) Operating tool with partially insulated shaft; Type, blade (2 x 04) mm; suitable for 279, 726, 727, 2000, 200 and 2020 series Operating tool with partially insulated shaft; Type 2, blade (3 x 0) mm; suitable for 260, 26, 262, 264, 270, 280, 28, 290, 77, 776, 777, 769, 780, 78, 869, 870, 880, 2002, 2003, 2004, 200 and 2022 Series Power supply unit; with universal mounting carrier; AC 230 V / DC 24 V,; Output voltage indication Power supply unit; with universal mounting carrier; AC V / DC 24 V,; Output voltage indication Shield clamping saddle; mm wide; diameter of compatible conductor; up to 8 mm Shield clamping saddle; 9 mm wide; diameter of compatible conductor; 7 mm to 6 mm Shield clamping saddle; 27 mm wide; diameter of compatible conductor; 6 mm to 24 mm Shield clamping saddle; 43 mm wide; diameter of compatible conductor; 22 mm to 40 mm 0 6
7 Printview: 4-channel analog input module; 4-20 ma; Single-ended - Item No: 70-4 Images & drawings 7
8 Printview: 4-channel analog input module; 4-20 ma; Single-ended - Item No:
9 Printview: 4-channel analog input module; 4-20 ma; Single-ended - Item No: 70-4 Address Hansastr Minden Telefon: 07/887-0 Fax: 07/ Technische Änderungen und Irrtümer vorbehalten 9
8-channel digital input module; 24 VDC; 3.0 ms; high-side switching; 1-conductor connection
Printview: 8-channel digital input module; 24 VDC; 30 ms; high-side switching; -conductor connection - Item No: 70-430 8-channel digital input module; 24 VDC; 30 ms; high-side switching; -conductor connection
More informationSwitching relay terminal block; Relay with 1 changeover contact (1u); with miniature switching relay
relay - Item No: 89-304 Switching relay terminal block; Relay with changeover contact (u); with miniature switching relay Item No: 89-304 Switching relay terminal block; Relay with changeover contact (u);
More informationWAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany
522 WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany WAGO Products: WAGO-I/O-SYSTEM with ETHERNET Controllers, DALI and EnOcean Components Wireless Technologie System Overview 524
More informationPOWER CAGE CLAMP High-Current Terminal Blocks for Conductors up to 350 kcmil (185 mm 2 )
POWER CAGE CLAMP High-Current Terminal Blocks for Conductors up to 350 kcmil (185 mm 2 ) vibration-proof fast maintenance-free WAGO BENEFITS Using springs instead of screws is the key to WAGO s success.
More informationTRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:
Extract from the online catalog TRIO-PS/1AC/24DC/ 5 Order No.: 2866310 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 5 A Commercial data EAN 4046356046640 Pack 1 pcs. Customs
More informationPOWER CAGE CLAMP High-Current Terminal Blocks for Conductors up to 350 kcmil (185 mm 2 )
POWER CAGE CLAMP High-Current Terminal Blocks for Conductors up to 350 kcmil (185 mm 2 ) vibration-proof fast maintenance-free WAGO BENEFITS Using springs instead of screws is the key to WAGO s success.
More informationAnalog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/
> 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationDigital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22
www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationOperating tools. with partially insulated shaft Type 1, 2 and 3 in set
Accessories 40 Accessories 41 Operating Tools 42 45 Operating Tools WINSTA 46 47 Disconnection Tools 48 Cable Strippers 500 Wire Strippers 501 Cable Cutters 502 Crimping Tools 502 503 Test and Measurement
More informationDatenblatt. W-Series WDU 2.5
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationMACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:
Extract from the online catalog MACX MCR-EX-T-UI-UP Order No.: 2865654 Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer
More informationExtract from the online catalog
Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The
More informationDatenblatt. W-Series WDU 10
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationâ Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)
Technical information itemp TC TMT128 DIN rail mounted Temperature Transmitter for Thermocouples (TC) Application Temperature transmitter with fixed measuring ranges for converting TC input signals into
More informationTemperature head transmitter itemp TC TMT 188
Technical information TI 077R/24/ae No.: 510 06145 Temperature head transmitter itemp TC TMT 188 Universal head transmitter for thermocouples for an economical, high accuracy temperature monitoring. Fixed
More informationMCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:
Extract from the online catalog MCR-C-UI-UI-DCI Order No.: 2810913 MCR 3-way isolating amplifier, with configurable I/O, for the electrical isolation of analog signals, with GL approval, preconfigured.
More informationTemperature transmitter itemp RTD DIN rail TMT 127
Technical information TI 095R/24/ae Nr. 510 06165 Temperature transmitter itemp RTD DIN rail TMT 127 Pt100 transmitter for an economical, high accuracy temperature monitoring. Fixed range measurement,
More informationPHOENIX CONTACT
Selective circuit breaker CLIPLINE Data sheet 100464_en_05 PHOENIX CONTACT 2009-11-17 1 Description The electronic circuit breaker, which has a design width of just 12.5 mm, selectively protects all 24
More information0 2 1 â Ó. itemp HART TMT182. Technical Information
Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for
More informationTemperature sensor with integrated transmitter for maritime applications, MBT 5560
Temperature sensor with integrated transmitter for maritime applications, MBT 5560 Technical brochure Features Designed for use in harsh maritme environments where reliable, robust and accurate equipment
More informationThe shield (screen) connecting system from WAGO offers high electrical and mechanical safety for very flexible applications.
The shield (screen) connecting system from WAGO offers high electrical and mechanical safety for very flexible applications. Shield (Screen) Connecting System VOLUME 1 Shield (screen) connecting system
More informationData sheet. W-Series WDU 2.5
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More information08/07/2015
17.5 mm - 1 Solid State Relay 0.7A MUS2 Part number 88827004 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external
More informationAnalog Universal Module HART for Zone 2 Series 9468/33
> 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on
More informationRelative pressure transmitter type 522 for shipbuilding
Relative pressure transmitter type 522 for shipbuilding Pressure range 0... 2.5 1000 bar The compact type 522 pressure transmitter for shipbuilding is based upon the Huba Control developed thick film technology
More informationDigital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version
Electrical temperature measurement Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 Applications Process industry Machine building
More informationNOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog
NOVOHALL Rotary Sensor non-contacting Series RSC2800 analog The RSC 2800 sensor utilizes a contactless magnetic measurement technology to determine the measured angle. Unlike conventional Hall sensors,
More informationEC centrifugal fan. forward curved, dual inlet with housing (flange)
D3G46-AH- ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 7938 8- Fax +49 7938 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court
More informationDigital Input Module 24 V Ex n Inputs, 16 Channels Series 9471
> 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels
More informationFeed-through terminal block - PT 10-TWIN
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid
More informationPHOENIX CONTACT
Electronic circuit breaker CLIPLINE Data sheet 102898_en_03 PHOENIX CONTACT 2010-12-17 1 Description The electronic circuit breaker can be used in applications that cover all aspects of the switched-mode
More informationAnalogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting
Electrical Temperature Measurement Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting WIKA Data Sheet TE 24.01 Applications T Machinery, plant construction T Process industry
More informationRudder or propeller angular position transmitter KINAX WT720
Description The is a robust, absolute angular position transmitter, which is particularly suitable for use in marine applications such as the detection of rudder or propeller positions. In contrast to
More information20 General technical data XI/ON
20 General technical data XI/ON General technical information General technical data XI/ON Potential isolation Ambient temperature Operating temperature Storage temperature Relative humidity Noxious gas
More informationMagnetic absolute encoder GEL 2035 Serial interface (SSI), 24 Bit
Magnetic absolute encoder GEL 2035 Serial interface (SSI), 24 Bit Technical information Version 03.09 Resolution: Precision: 0.8 Signal pattern: Singleturn (ST): Multiturn (MT): up to 24 Bit SSI and SSI
More informationDigital Input Output Module for Zone 1 Series 9470/32
www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used
More informationMINI MCR-SL-UI-f(-SP)
Configurable Analog Frequency Transducer INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The configurable analog frequency transducer MINI MCR-SL-UI-f(-SP) is used to convert analog standard
More informationIsolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series
Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration
More informationATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW
Characteristics soft starter for asynchronous motor - ATSU01-32 A - 200..480V - 7.5..15 KW Main Range of product Product or component type Product destination Product specific application Device short
More informationIsolators A3/1. Vibration Transducer Supply Unit Series
> For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic
More informationProtection components
General Application LT3-Si thermistor protection units continuously monitor the temperature of the machines to be protected (motors, generators, etc.) by means of PTC thermistor probes embedded in the
More informationAF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF
ABB AF12-30-01-14 250-500V50/60HZ-DC Contactor General Information Extended Product Type Product ID AF12-30-01-14 1SBL157001R1401 EAN 3471523110441 Catalog Description Long Description AF12-30-01-14 250-500V50/60HZ-DC
More informationScrew-in resistance thermometers with plug connector
Data Sheet 90.2004 Page 1/7 s with plug connector for temperatures from -50 to +300 C highly resistant to shock and vibration connector locked in for reliable contact, IP65 or IP69K protection available
More informationATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW
Characteristics soft starter for asynchronous motor - ATSU01-22 A - 200..480 V - 4..11 KW Price* : 195.00 GBP Main Range of product Product or component type Product destination Product specific application
More informationMeasuring current transformers of the W, W series
Measuring current transformers of the W, W -8000 series W(-8000)_D00078_01_D_XXEN/09.2015 Measuring current transformers of the W, W -8000 series Product description The highly sensitive W and W -8000
More informationSmart Power Relay E I...
Smart Power Relay E-48-8I... Description The Smart Power Relay E-48-8I.- is a remotely controllable electronic load disconnecting relay with three functions in a single unit: l electronic relay l electronic
More informationElectronic Circuit Breaker with reset input ESS20-1..
Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and
More information02/11/2015
Smart range with Removable Terminal blocks XD26RBT Smart Part number 88974561 Designed for industrial, commercial, medical and paramedical machines Faster maintenance process which improves the machine
More informationTemperature controller, 4-channel
, 4-channel Subject to technical modification 716218 Identification Type TR-1-6218 4-channel Part-No. 716218 Use/Area of application Description The temperature controller has 4 separate channels. The
More informationLVDT. Inductive Position Transducer. SL Series. Key-Features:
LVDT Inductive Position Transducer SL Series Key-Features: Content: - Measurement ranges 10...600 mm - External, or cable electronics with cable break detection - Linearity up to ±0.10 % of full scale
More informationâ itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring
Technical information itemp Pt100 TMT127 Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring Application Temperature transmitter with fixed measuring range for converting a
More informationMCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description
Universal current transducer Data sheet 104059_en_05 PHOENIX CONTACT 2011-03-09 1 Description MCR-SL-CUC-...-I and MCR-SL-CUC-...-U active current transducers convert DC, AC, and distorted currents into
More informationJUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver
Page 1/13 JUMO Wtrans E01 Measuring probe for humidity, temperature, and CO 2 with wireless data transmission Humidity from 0 to 100 % RH (incl. -40 to +80 C) or CO 2 from 0 to 2000/5000/10000 ppm or Temperature
More informationA new approach to static electricity countermeasures
Advanced intelligent Sensors NEW ELECTROSTATIC SENSOR EF-SSERIES A new approach to static electricity countermeasures Measurement of surface potentials while a production line is running Phone: 8.894.42
More informationonlinecomponents.com
Key features: Relay Barrier: Intrinsically Safe Explosion-Proof: EB3C Relay [Exia] II C IEC0079 compliant Dry-contact switches can be connected to the EB3C 8- and 1-circuit types are available in common
More informationZelio Control Measurement Relays
Selection Guide Application Voltage control Current control Functions 3-phase Single-phase and d.c. Integrated current transformer - Overvoltage and between phases - Overvoltage and between phases and
More informationMeasuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC
2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from
More informationisolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems
T M 1 isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems Technical Bulletin NAE1012110 / 12.2011 isolr275 / AGH-LR Ground Fault Monitor
More informationSolid State Relay, 1-phase
PMA Prozeß- und Maschinen-Automation GmbH Solid State Relay, 1-phase Short-Circuit Proof, heat sink integrated Main Characteristics: Standards / Approvals: CE C-Ti I Zero-point switching Short-circuit
More informationType Nominal voltage (V) Code HSV V
Speed control Speed control relay - mm Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - -wire PNP or NPN, Namur, voltage 0-0V or volt-free contact type Works
More informationMain catalogue. SNK Series Terminal Blocks Accessories Marking Solutions
Main catalogue SNK Series Terminal Blocks Accessories Marking Solutions 10 5.2 mm m 0.205 in spacing 53 2.09" 26.7 1.05" 3 4 5 6 7 8 9 10 Save space by connecting s up to 4 mm2 (CB certified) 12 AWG in
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series
Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input
More informationATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW
Characteristics soft starter for asynchronous motor - ATS01-25 A - 110..480V - 2.2..11 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application Device
More informationData sheet... W-Series WDU 2.5
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW
Characteristics soft starter for asynchronous motor - ATS01-12 A - 110..480V - 1.5..5.5 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application
More information6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)
6ES7214-1AG31-0XB0 Page 1 Product data sheet 6ES7214-1AG31-0XB0 SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V
More informationData sheet. W-Series WDU 2.5 RT
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationSignal conditioner - MACX MCR-UI-UI-NC
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid
More informationThrough and Ground Conductor Terminal Blocks 290 Series
11 474 Through and Ground Conductor Terminal Blocks 290 Series 0.34-1. mm"f-st" 0.31-1 mm"s" 1 00 V/6 kv/3 2 1 AWG 22-16"f-st" AWG 22-18"s" I N 13. A Terminal block width mm / 0.197 in 0.34-1. mm"f-st"
More informationIntrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F
Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE
More informationLVDT. Inductive Position Transducer. SL Series. Key-Features:
HM-1803 LVDT Inductive Position Transducer SL Series Key-Features: Content: - Measurement ranges 10...600 mm - External, or cable electronics with cable break detection - Linearity up to ±0.10 % of full
More informationED701 General Industry Pressure Transmitter
ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW
Characteristics soft starter for asynchronous motor - ATS01-3 A - 110..480V - 0.55..1.1 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application
More informationIXARC Incremental Encoder UCD-IPT M100-PRD. Interface Programmable Incremental. Configuration Tool UBIFAST Configuration Tool (Version 1.6.
IXARC Incremental Encoder UCD-IPT00-08192-M100-PRD Interface Interface Programmable Incremental Programming Functions PPR (1-16384), Output, Counting Direction Configuration Tool UBIFAST Configuration
More information02/11/2015
Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.
More informationMINI MCR-SL-UI-I-LP-NC
2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals.
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8
More informationCoupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC
Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation
More informationIsolating Repeater Input Series 9163
> For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de
More informationMeasuring current transformers of the W B series
Measuring current transformers of the W B series W-B_D00075_01_D_XXEN/09.2015 Measuring current transformers of the W B series Product description Measuring current transformers of the W B series are highly
More information08/07/2015
17.5 mm - 1 Relay 8A MUR1 Part number 88827105 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external load connection
More informationSINEAX U 553 Transducer for AC Voltage
With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U 55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load
More informationDIK 1,5 General data Technical data General
General data Order number 2715966 Type DIK 1,5 Barcode number 4017918061715 Unit pack 50 Pcs. Customs tariff 85369010000 Technical data General Number of levels 3 Number of connections 4 Color gray Insulating
More informationDigital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version
Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications
More informationSINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage
Application The transducers SINEAX I 503/U 504 (Figs. 1 and 2) are designed to convert a sinusoidal AC current or voltage into a load independent DC signal proportional to the measured value. This output
More informationTL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models
Standard Flat Inductive Proximity Sensors Front and side facing surface IP67 DC -wire and DC -wire models Ordering Information DC -wire Models Shape distance Model Output and operating status mm MD1 *1
More informationMCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description
Voltage transducer for AC voltages TERFACE Data sheet 006_en_0 PHOENIX CONTACT 00-0- Description The MCR voltage transducer measures AC voltages in several signal ranges from 0... ±4 V AC to 0... ±30 V
More information02/11/2015
Smart "Compact" range with display CD20 Smart Part number 88974053 Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting Allow the use of the entire library of specific functions
More information3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/
3 Ex i Isolators Switching Repeater with Power Relay Intrinsically safe input [Ex ia] IIC Galvanic isolation between input, output and power supply Open-circuit / short-circuit monitoring and messaging
More informationA6500-UM Universal Measurement Card
Specifications Sheet A6500-UM Universal Measurement Card The A6500-UM Universal Measurement Card is a component of the CSI 6500 ATG machinery protection system. The card is equipped with 2 sensor input
More informationElectronic Circuit Breaker ESS20-0..
Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,
More informationFieldbus Isolating Repeater Series 9185/11
www.stahl.de > For operation of the intrinsically safe Profibus DP (RS-485 IS to PNO standard) > Intrinsically safe fieldbus RS-422, RS-485 [Ex ib] IIC > Galvanic isolation between RS-422 / RS-485, RS-232,
More informationCP-T range Benefits and advantages
Benefits and advantages Characteristics Rated output voltages V, V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output currents 5 A, 10 A, A, A Rated output powers
More informationOEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted
Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 Applications Machine building, plant and vessel construction Propulsion
More informationPHOENIX CONTACT - 09/2009
Electronic miniature circuit-breaker CLIPLINE Data sheet 03906_en_0 PHOENIX CONTACT - 09/2009 Description The EC-E... electronic miniature circuit-breaker selectively protects all 24 V DC load circuits
More informationTotalizing Counters mini-i
mini-i Type 634/635 Type 634: Counter with high immunity against magnetic interfere Type 635: Counter with high shock stability Miniature size Low power consumption Electrical connections in standard grid
More informationEVOLUTE absolute optical encoder with Yaskawa serial communications
L-9515-9641-01-C EVOLUTE absolute optical encoder with Yaskawa serial communications True absolute non-contact optical encoder system: no batteries required Wide set-up tolerances for quick and easy installation
More informationTemperature Sensors Types MBT 5250, MBT 5260 and MBT 5252
Data sheet Temperature Sensors Types MBT 5250, MBT 5260 and MBT 5252 MBT 5250 MBT 5260 MBT 5252 Heavy-duty temperature sensors for controlling cooling water, lubrication oil, hydraulic oil and refrigeration
More informationThree-phase monitoring relay CM-PFS
Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available
More informationC330 / C330X PC-Programmable Universal, 2-wire Transmitter
C330 / C330X PC-Programmable Universal, 2-wire Transmitter The IPAQ C330 transmitter is a universal, isolated, temperature transmitter with additional voltage and resistance input. Its robust design and
More information