Customer Interface Unit (CIU)
|
|
- Conrad Perkins
- 6 years ago
- Views:
Transcription
1 Operation and Instruction Manual Customer Interface Unit 1:1:10 16:49:0 Fr1 HPL Electric & Power Pvt. Ltd. Overload Power * 0 # RAILWAY/OC(1P) HPL ELECTRIC & POWER PVT. LTD. 1/1, Asaf Ali Road, New Delhi Phone: , 4811, Fax: hpl@hplindia.com, Website : (Due to continuous development, specification and features are subject to change without prior notice.) BSI R E GI S T E R E D UKAS QUALITY MANAGEMENT 00 ISO-9001:008 HPL Electric & Power Pvt. Ltd.
2 Contents 1. General Information...1. Installation...1. Front View Operation.... Display:... a. Auto Scroll Mode... b. Keypad Mode Vending Code Entry LED indication...8 a. LED Alarm Indication: a. Low Alarm: The buzzer beeps at every 0 minutes when balance is less than 100, excluding Happy Hours i.e. 17:0 to 11:00. b. Overload Alarm: The buzzer beeps when overload occurs i.e. current greater than the load-limit. Over load condition: If load is higher than the load limit, meter will CUT- OFF the load for one minute and raise alarm. If the load is not reduced below load-limit, Meter repeat this for three times automatically and then meter CUT-OFF the load and shall not reconnect it automatically. Now you need to lower the load and press # key for 4 Seconds, to reconnect the load. During overload following indication comes: 1:1:10 Load disconnect 16:49:0 FRI * If Meter is at low credit then it can be MUTE by pressing # key for 4 seconds. b. Overload LED...8 c. Power LED Alarm Indication...9 a. Low Alarm...9 b. Overload Alarm...9 Operation and Instruction Manual Operation and Instruction Manual 9
3 Vending Code Result 1. Not valid code. Old token Typical Screen Shots Not Not Caution This equipment must be keep away from water. The manufacturer shall not be held responsible for failure to comply with the instructions in this manual.. Used token 4. Sequence Error. Successful entry for setting maximum load limit token 6. Successful entry for emergency credit limit token 7. Successful entry for setting of fix charges token 8. Successful entry for tariff token 9. Successful entry for credit token 10. Successful entry for meter rent LL 60 EC Fc Not Not A 1. General information: a. is used to view/access the display parameters and Token entry. b. CIU does not need any external supply or batteries, it is powered up through meter via communication cable. c. CIU is supplied with RS48 connector & cable. d. It can be connected to meter with cable for communication between meter and CIU unit. 11. Successful entry for refund credit amount 7. LED Indication: a. LED: i. When credit LED is in GREEN colour, it shows that credit balance in meter is greater than 100. ii. When credit LED is in RED colour, it shows that credit balance is less than 100. iii. When credit LED is in ORANGE colour, it shows that meter is in debit. b. Over Load LED: When Overload load LED glow, it shows overload occurrence. c. Power LED: When power LED is ON, it shows that CIU power is ON.. Installation: a. Connect the CIU to meter with given RS48 cable. b. Ensure that the cable has been locked with its connector. Meter Connection Diagram CIU RS 48 RS 48 Operation and Instruction Manual 8 Operation and Instruction Manual 1
4 . Front view: b Customer Interface Unit 1:1:10 16:49:0 Fr1 HPL Electric & Power Pvt. Ltd. a c d Note : 1. Meter rent are charges that are applied on per month. This can be changed as applicable by Utility.. Current Tariff is tariff, in which meter is currently running.. Fix charges are the charges, that are applied either monthly or daily basis as decided by Utility. These charges can be changed by Utility. 4. Minimum charges are applied per month. If the consumer consumes electricity equivalent of amount less than the minimum charges then at the end of the billing period the meter will deduct the difference of the minimum amount and the monthly consumption (amount). f Overload Power e 6. Vending Code Entry: To enter the 1 digits Numeric Vending Code in the meter, follow below steps: * i. Press key for 4 seconds then it will show display. i.e. insert Token No.1. a. LCD b. Overload LED c. LED d. Power LED e. Buzzer f. Numeric Keypad 4. Operation: As soon as the CIU is connected to meter, it is powered up and performs the LCD segment check then goes to Auto Scroll Mode display. ii. After entering 9 digits it shows display as below iii. Enter full 1 digit Vending Code. Then it shows display as below Number of digits entered. ok 1 This number shows no. of digit entered. Please check OK before entering Token. iv. Press # key to accept the Token. v. Display will show the following results : Note : In token entry mode, if you entered any wrong entry, please press * entry, this is equivalent to backspace. to clear wrong. Display: There are two modes of display. A. Auto Scroll Mode B. Keypad Mode Operation and Instruction Manual Operation and Instruction Manual 7
5 Note : ABC is 1 digit code shown in typical screen one after another automatically as shown. This code generated by meter automatically at end of every month. This code is used by Utility to get information about meter i.e. 1. Meter Serial Number. Balance Amount. reading of meter 6. Cover Open Status. ABC generation date 7. ABC Upload 4. Tamper statusof meter 7. kw Maximum Demand in kw 8. MD 7 8:10:10 9:0 MD Maximum Demand & Note : Screen number 7 & 8 can be shown one after another automatically by pressing key Cumulative Balance Amount 0.00 Meter Rent 0.00 Fc Previous day Consumed Amount Current Tariff Fix Charges (Monthly) 44. Minimum Charges Number of Transaction Accepted (ACPT) by meter Number of Transaction Rejected 6 (RJtD) by meter Total Cumulative Amount Vended in meter 1:1:10 16:49 Real & with weekday. Meter Serial Number to which CIU is connected A. Auto Scroll Mode: Typical screenshots shows as given below, when CIU is connected to meter Current load and the cost of that load sl6 kw Cumulative Energy in with Slab No. & Balance Amount Note: The parameter in Auto Scroll Mode will automatically scroll one by one at every 10 sec. interval. B. Keypad Mode : The parameters in this mode can be viewed by pressing numeric keys given at CIU front :1: :01:11 1:8 9. 0: Last Retained Code Part-1 (RET) Last Retained Code Part- (RET) Last Retained Code Part- (RET) Last Retained Code & time Last Retained Code Amount nd Last Retained Code Part-1 (RET) nd Last Retained Code Part- (RET) nd Last Retained Code Part- (RET) nd Last Retained Code & time nd Last Retained Code Amount rd Last Retained Code Part-1 (RET) rd Last Retained Code Part- (RET) Operation and Instruction Manual 6 Operation and Instruction Manual
6 :11:10 10: :08: : :06:11 1: rd Last Retained Code Part- (RET) rd Last Retained Code & time rd Last Retained Code Amount 4th Last Retained Code Part-1 (RET) 4th Last Retained Code Part- (RET) 4th Last Retained Code Part- (RET) 4th Last Retained Code & time 4th Last Retained Code Amount th Last Retained Code Part-1 (RET) th Last Retained Code Part- (RET) th Last Retained Code Part- (RET) th Last Retained Code & time th Last Retained Code Amount Note: 1. Retained Code (RET) is the Tokens entered. This code is shown in typical screens, one after another automatically, after pressing key 1 on numeric keypad as shown here.. Retained credit code & time is the date & time when Token was entered. 6. Day Left (based on consumption of last seven days) Note: Days left : This shows that how many days you can run the load, without recharging the meter (based on consumption of last seven days). Meter is programmed for based tariff structure. Tariff Structure Tariff - 1 Tariff - Tariff - Tariff Screen number 7 to 0 shall be shown one after another automatically by pressing key. Note : In above screen the Tariff structure is as follows : Slab No. Start End () above 4.90 Tariff 1 : This shows the end of 1st slab of your Tariff in and rate applied for this tariff as shown in table. First Slab start from 0. Tariff : This shows the end of nd slab of Tariff in with rate applied and it start from 1st slab tariff ending. Tariff : This shows that end of rd slab of Tariff in with rate applied and it start from nd slab tariff ending. Tariff 4 : This shows that end of 4th slab of Tariff in with rate applied and it start from rd slab tariff ending kw Current load and the cost of that load Authenticated Billing Code Part Authenticated Billing Code Part- Authenticated Billing Code Part Total Cumulative Amount Vended in meter Operation and Instruction Manual 4 Operation and Instruction Manual
SINGLE PHASE STS PREPAID METER
SINGLE PHASE STS PREPAID METER Table of Contents 1 INTRODUCTION... 2 2 STANDARDS REFERENCES... 3 3 TECHNICAL PARAMETERS... 3 3.1 Meter operating voltage... 3 3.2 Meter current parameters... 3 3.3 Meter
More informationCAPITAL ELECTRICAL DIVISION ITANAGAR
GOVERNMENT OF ARUNACHAL PRADESH DEPARTMENT OF POWER BID DOCUMENT PART-III (Volume-2/3) TECHNICAL SPECIFICATIONS OF AUTOMATION OF ELECTRIC ENERGY METERING AND BILLING WITH AMR AND PRE-PAID METERS IN CAPITAL
More informationAPL SEM 1P V2. Single phase Keypad Prepayment Energy Meter. Technical Manual
APL SEM 1P V2 Single phase Keypad Prepayment Energy Meter Technical Manual Table of Contents 1. Use Instruction... 1 1.1 Overview... 1 1.1.1 Construction Profile... 1 1.1.2 Major Application... 1 1.1.3
More informationShenzhen Star Instrument Co., Ltd.
Shenzhen Star Instrument Co., Ltd. Three Phase Keypad Prepayment Electronic Energy Meter(Type C) - Design Specification Shenzhen Star Instrument Co., Ltd. R&D Center April of 2012 1. Introduction 1.1 Aim
More informationThis is a single phase 2 wire split prepayment keypad meter approved by STS A.It can access to any STS standard system.
1 1 1 1. Introduction This is a single phase 2 wire split prepayment keypad meter approved by STS A.It can access to any STS standard system. Built-in 100A relay which can trip when over load or balance
More informationRM600 Carrier Grade E1 Radios
Carrier Grade E1 Radios Quick Start Guide Package Contents ODU 1 IDU 1 Mast/Wall Mounting Kit 1 Outdoor Ethernet Cable (Optional) 1 External Antenna (Optional) 1 Power Supply Cable 1 Quick Start Guide
More informationShelti, Inc. 333 Morton Street Bay City, MI Phone Fax. Bayside Dollar Bill Acceptor Pool Table Manual & Instructions
Shelti, Inc. 333 Morton Street Bay City, MI 48706 989-893-1739 Phone 989-893-1809 Fax Bayside Dollar Bill Acceptor Pool Table Manual & Instructions Contents Section-1 Introduction Bayside DBA Pool Table
More informationStay in control with your prepayment meter
Stay in control with your prepayment meter Your prepayment meter allows you to remain in charge of your energy usage. Keep on top of how much electricity you re using, budget for the future and rest assured
More informationEltek TU GenII GD900A Energy monitor (multidrop NDRail350) transmitter user instructions
Eltek TU1043 - GenII GD900A Energy monitor (multidrop NDRail350) transmitter user instructions System configuration diagram GD900A NDRail350 AC supply 240V nominal RS485 AC AC AC For 1 x three phase load
More informationCS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL
CS-200 PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL CS-200 Operation and Service Manual Page 2 Manufactured by: LINCAST INTERNATIONAL PTY. LTD. 2/3 Sir Laurence Drive
More informationMD-5060 DIGITAL MEGOHMMETER
DIGITAL MEGOHMMETER ( M98126501-03 / 04A ) TECHNICAL SPECIFICATIONS OPERATING INSTRUCTIONS DESCRIPTION The CIRCUTOR model MD-5060 digital electronic ohmmeter is a versatile, robust and easy-to-use equipment.
More informationM O D U L E - 7 D Model CS-CAL/DLIU V6.0 Operator s Manual
O P E R A T I O N S A N D P R O C E D U R E S F O R C S - C A L / D L I U V 6. 0 A N D A C C E S S O R I E S Model CS-CAL/DLIU V6.0 Visual screen display allows easy step-by-step operation Rechargeable
More informationENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS
ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS Copyright 2002-2006 PRI Ltd. 9600-3004-2 Issue C Information contained within this document is subject to change without notice and does not represent
More informationWIRELESS Energy Monitor - Smart Meter
Energy saving made simple MONITOR CONTROL SAVE WIRELESS Energy Monitor - Smart Meter Monitors your electricity use and cost in real time Instruction Manual EW4500 IMPORTANT Please retain your Instruction
More informationUser Manual Digital Multimeter. model no.: MSR-U1000
User Manual Digital Multimeter model no.: MSR-U1000 This Operating Manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings and Notes
More informationINFOCAL 8 Energy calculator
Data sheet INFOCAL 8 Energy calculator Description/Application MID examination certificate no.: DE-10-MI004-PTB008 The INFOCAL 8 is an energy calculator e.g. for combination with SONO 1500 CT especially
More informationBrunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2
Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 UK-QB101575 / 29.05.2012 Brunata a/s is a Danish owned company. We have more than 90 years of experience within developing and producing
More informationSULTANATE OF OMAN METERING AND DATA EXCHANGE CODE
1.0 GENERAL SULTANATE OF OMAN METERING AND DATA EXCHANGE CODE STANDARD: OES-22F THREE PHASE KILOWATT-HOUR DIGITAL METERS, CURRENT TRANSFORMER OPERATED, CONNECTED FOR SERVICE CONNECTIONS Electronic three
More informationMunti-Coin Acceptor / Validator RS232 Serial Communication Protocol & Pulses Output
Munti-Coin Acceptor / Validator RS232 Serial Communication Protocol & Pulses Output Technical Manual May 20, 2015 Version: 01 Model: CX-363CA v.1 Used on: SMOVE/Poland *attached to face plate A *attached
More informationMicromate User Manual
Microcoin Table of Contents Page Essential Information 2 1.0 Connection and Configuration 3 1.1 Connection 3 1.2 Switch On 4 1.3 Configuration for Use 4 2.0 Check the Configuration of a Validator 5 2.1
More informationEnglish. Money Counter. Coin and banknote counter. DEUTsCH. Manual
ITALIANO ESPAÑOL FRANçAIS NEDERLANDS English Money Counter DEUTsCH Coin and banknote counter Manual Money Counter for Coins and Banknotes Introduction Thank you for choosing the Money Counter series. The
More informationScoreboard Operator s Instructions MPCW-7 Control
Scoreboard Operator s Instructions MPCW-7 Control Some features on the keyboard overlay may not be included on the particular model being operated. Since 1934 2/24/2016 135-0222RC These Instructions are
More informationTV SIGNAL LEVEL METER USER MANUAL
TV SIGNAL LEVEL METER USER MANUAL - 0 - 1. Overview (1) (1) RF input (2) (3) A D E B C (2) Speaker (3) LCD display (4) Charger indicator (5) RS232 communication port (6) DC-IN port F G A. The battery icon
More informationGROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer INSTALLERS MANUAL
GROUP OF COMPANIES MERLIN STEALTH Electric Fence Energizer INSTALLERS MANUAL Revision 1.5 23 February 2007 : INSTALLERS MANUAL Table of Contents 2 INTRODUCTION.. 3 INSTALLER OPTIONS...... 4-11 ALARM SETTING
More informationOperating Instructions
CMYX Color mark sensor Operating Instructions CAUTIONS AND WARNINGS SET-UP DISTANCE ADJUSTMENT: As a general rule, the sensor should be fixed at a 15 to 20 angle from directly perpendicular to the target
More informationCOD GB / 1.0 RBAND/UMS - RBAND/CSM
INTRODUCTION DESCRIPTION The RadioBand system is designed of Industrial, Commercial and Domestic door and gate applications where a safety edge is used. The system provides a wireless system replacing
More informationSonoMeter 31 Energy Meters
SonoMeter 31 Energy Meters Description MID examination certificate no.: LT-1621-MI004-023 The Danfoss SonoMeter 31 is a range of ultrasonic, compact energy meters intended for measuring energy consumption
More informationScoreboard Operator s Instructions MPCW-7 Control
Scoreboard Operator s Instructions MPCW-7 Control Some features on the keyboard overlay may not be included on the particular model being operated. Since 1934 2/24/2016 135-0223RC These Instructions are
More informationPEM353. Universal measuring device
353 Universal measuring device 353_D00335_00_D_XXEN/06.2018 353 Universal measuring device Product description The digital universal measuring device 353 is used to record and display measured quantities
More informationDC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL
DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL Warnings and Safety symbols: Caution, refer to this manual before using the meter. Dangerous voltages. Meter is protected throughout by double insulation or
More informationR PROFLAME Instruction Book Collection
9.956.028 R00 584 PROFLAME Instruction Book Collection 4-17 18-29 584 PROFLAME System 30-39 Appendix: DIP SWITCH NUMBER (0=ON 1=OFF) 40-41 4-17 Fig. 1 The SIT is a device that allows, in conjunction with
More informationModel UT233 OPERATING MANUAL
Model UT233 OPERATING MANUAL TABLE OF CONTENTS TITLE PAGE Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure A. The Meter Front
More informationINSTALLATION HANDBOOK
Replacing Consumables Replacing the Lamps Lamp replacement period It is time to replace the lamp when: The message "Replace the lamp." is displayed at the lower left of the projection screen when you start
More informationSUNDIAL Light Dimmer. User's Manual
Light Dimmer User's Manual 1. PRECAUTIONS Although fuses at the input and outputs of the controller protect its circuits in case of an overload or overvoltage, we recommend installing an additional protection
More informationSmart Prepaid Meter Specification: 3ph-WCM. Three Phase Whole current Meter with GPRS/3G communication
Smart Prepaid Meter Specification: 3ph-WCM Three Phase Whole current Meter with GPRS/3G communication 1 CONTENTS 1.0 SCOPE... 3 2.0 STANDARDS... 3 3.0 TECHNICAL SPECIFICATION... 4 4.0 SMART METER FEATURES...
More informationActi 9 Energy Meters. iem3000 Series. Technical data sheet
Acti 9 Energy Meters iem3000 Series Technical data sheet PB108410 b The Acti 9 iem3000 Energy Meter Series offers a cost-attractive, competitive range of DIN rail-mounted energy meters ideal for sub-billing
More informationSHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100
APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the
More informationTrue RMS Digital Multimeter Model:
True RMS Digital Multimeter Model: 72-7780 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,
More informationDirect Print User Guide You don t even need a computer! Just connect your camera to your printer and print
Direct Print User Guide You don t even need a computer! Just connect your camera to your printer and print CDI-E301-010 XXXXXX 2006 CANON INC. PRINTED IN JAPAN DPUG13 ENGLISH Introduction Confirm Your
More informationScoreboard Operator s Instructions MPCW-7 Control
Scoreboard Operator s Instructions MPCW-7 Control Some features on the keyboard overlay may not be included on the particular model being operated. Since 1934 3/27/2018 135-0222RC These Instructions are
More informationMS2109A AC/DC Clamp Meter. User Manual. Contents
MS2109A AC/DC Clamp Meter User Manual Contents 1. Safety information 1 1.1 Preparation 1 1.2 Usage 1 1.3 Signs and Labels 2 1.4 Maintenance 2 2. Description 2 2.1 Part name 3 2.2 Switch and button description
More informationME371, MT371 Single- and Three-Phase Electronic Meters with Built-in DLC Communication Channel
Energy Measurement and Management ME371, MT371 Single- and Three-Phase Electronic Meters with Built-in DLC Communication Channel ME372, MT375 Single- and Three-phase Electronic Meters with Built-in GSM/GPRS
More informationPrinting Humidity/Temperature Meter
Printing Humidity/Temperature Meter INSTRUCTION MANUAL I. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter only as specified
More informationEmbedded Generation Connection Application Form
Embedded Generation Connection Application Form This Application Form provides information required for an initial assessment of the Embedded Generation project. All applicable sections must be completed
More informationContinuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3
Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3 GHz Magnetic fields monitoring from 10 Hz to 5 khz Automatic
More informationInstruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information
Instruction INFOCAL 8 Energy calculator 1.0 Table of contents 1.0 Table of contents...1 2.0 Safety notes and product information...1 3.0 Installation of energy calculator...2 4.0 Installation of temperature
More informationScoreboard Operator s Instructions MPCW-7 Control
Scoreboard Operator s Instructions MPCW-7 Control Some features on the keyboard overlay may not be included on the particular model being operated. Since 1934 3/27/2018 135-0217RD These Instructions are
More informationDAB+ / FM RDS digital clock radio with dual alarm
ROBERTS Enjoy Listening DAB+ / FM RDS digital clock radio with dual alarm Please read this manual before use Contents Controls... -3 Using the clock radio for the fi rst time...4 Operating your clock radio...5
More informationDigital Clamp Meter Model: &
Digital Clamp Meter Model: 72-7224 & 72-7226 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,
More informationADI-100 Interrupter. Operator s Manual. 526 S. Seminole Bartlesville, OK /
ADI-100 Interrupter Operator s Manual 526 S. Seminole Bartlesville, OK 74003 918/336-1221 www.sescocp.com ADI - 100 Interrupter FEATURES Clock Accuracy 100% during GPS lock Clock Drift 30 µsec per degree
More informationMT174 Three-Phase Static Electricity Multi Tariff Meter with Maximum Demand Indicator and Load-profile
Energy Measurement and Management MT174 Three-Phase Static Electricity Multi Tariff Meter with Maximum Demand Indicator and Load-profile Technical Description Version 1.2, 18.08.2011 Index: MT174 - Electronic
More informationActi 9 Energy Meters. iem3000 Series. Technical data sheet
Acti 9 Energy Meters iem3000 Series Technical data sheet 1 PB108410 b The Acti 9 iem3000 Energy Meter Series offers a cost-attractive, competitive range of DIN rail-mounted energy meters ideal for sub-billing
More informationEnergy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302
Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Direct connection up to 65 A (WSx10x) Connection with current transformer (WSx30x) Industrial or meters
More informationTOSHIBA International Corp
TOSHIBA International Corp GUIDE SPECIFICATIONS THREE PHASE UNINTERRUPTIBLE POWER SYSTEM TOSHIBA 4200FA 30 kva CT Internal Battery UPS GUIDE SPECIFICATIONS 1 (30 kva CT) 1.0 SCOPE 1.1 System This specification
More informationPREMIER INSTALLATION AND OPERATING INSTRUCTIONS
PREMIER INSTALLATION AND OPERATING INSTRUCTIONS Copyright 2002-2006, PRI Ltd. 9600-3003-2 Issue C Information contained within this document is subject to change without notice and does not represent a
More informationDEUTSCH NEDERLANDS ENGLISH ESPAÑOL FRANÇAIS PORTUGUÊS DAB2035
DEUTSCH ENGLISH FRANÇAIS NEDERLANDS ESPAÑOL PORTUGUÊS DAB2035 DAB2035 PLL FM Kitchen Radio 1 General Description DAB+ / FM band provide radio station name & automatic clock up-date An electronic module
More informationUT232. Operating Manual. Digital Power Clamp Meter
UT232 Operating Manual Digital Power Clamp Meter Model UT232 OPERATING MANUAL TABLE OF CONTENTS TITLE PAGE Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical
More informationMS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL
MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL Table of Contents TITLE PAGE 1. GENERAL INSTRUCTIONS 1 1.1 Precaution safety measures 1 1.1.1 Preliminary 1 1.1.2 During use 2 1.1.3 Symbols
More informationNEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :
NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata - 700 032, Tel : 033 2477 3126; Fax : 033 2477 2403 www.ntplindia.com SPECIFICATION NTPL MAKE MICRO-CONTROLLER BASED AUTOMATIC 50KV/10A AC HIGH VOLTAGE
More informationFINE INSTRUMENTS CORPORATION
Model 41 Resistance USER S MANUAL a world leader in test & measurement FINE INSTRUMENTS CORPORATION B11, A-DONG, SMART VALLEY, SONGDOMIRAE-RO 3, YEONSU-GU, INCHEON, KOREA - TEL: (82-32) 837-5777 - FAX:
More informationScoreboard Operator s Instructions MPCW-7 Control
Scoreboard Operator s Instructions MPCW-7 Control Some features on the keyboard overlay may not be included on the particular model being operated. Since 1934 Retain this manual in your permanent files
More informationMT174 Three-Phase Static Electricity Multi Tariff Meter with Maximum Demand Indicator and Load-profile
Energy Measurement and Management MT174 Three-Phase Static Electricity Multi Tariff Meter with Maximum Demand Indicator and Load-profile Technical Description Version 1.0, 05.05.2010 Index: MT174 Electronic
More informationSHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2
APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the
More informationScoreboard Operator s Instructions MPCW-7 Control
Scoreboard Operator s Instructions MPCW-7 Control Some features on the keyboard overlay may not be included on the particular model being operated. Since 1934 2/18/2016 135-0215RC These Instructions are
More informationPWM regulator for electrolysis cell Η 2
PWM regulator for electrolysis cell Η 2 Ο Red or Gray Battery positive end (+) via fuse 25Α (30Α max) Blue Positive PWM output towards solution 1 Brown Negative PWM output towards solution Solution state
More information200 RTH OFF ON IN OUT ALARM RESET
200 RTH OFF ON IN OUT ALARM RESET EN OWNER S MANU AL www.auraton.pl 2 3 Thank you for purchasing the modern temperature controller based on an advanced microprocessor. AURATON 200 RTH LCD FrostGuard function:
More informationMT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.
MT-3110 3 5/6 Smart Digital Clamp Meter User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd. 1.Safety Information Warnings Special attention shall be paid when using the meter, improper
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SG Series 80 100 120 kva 400 Vac CE Series 0 Date of issue: 01.11.2007 SGSE_080_UPS_GE_01a SGSE_100-120_UPS_GE_01a
More informationAccuracy : ± (0.8% rdg + 1dgt) on all ranges except Ranges : 200mV, 2V, 20V, 200V, 1000V
. SPECIFICATIONS Digital Multimeter Model : 0 Instruction Manual. General Specifications Display : ½ digit liquid crystal display (LCD) with a maximum reading of 999. Polarity : Automatic, (-)negative
More informationMT372 Three-phase electronic meter with built-in modem or RS485 communication interface
Energy Measurement and Management MT372 Three-phase electronic meter with built-in modem or RS485 communication interface Technical Description Version 1, 09.06. 2005 Content: MT372 Three-phase electronic
More informationMS2030 CAT III 600 V A V AUTO RS232
MS2030 AC Digital Clamp Meter User s Manual CAT III 600 V AUTO RS232 A V CONTENTS 1.Introduction...1 2.Safety Information...1 2.1 Precautions...1 2.2 Safety Symbols...3 3. Description...4 3.1 Front Panel...4
More informationMULTIBAND SCANNING RECEIVER INSTRUCTION MANUAL
TSC-000R MULTIBAND SCANNING RECEIVER INSTRUCTION MANUAL Manufactured by www.ttikorea.co.kr CONTENTS CAUTIONS... 5. SUPPLIED ACCESSORIES... 6. FITTING AND REMOVING THE BATTERY PACK... 6. INSTALLING THE
More informationPrecise Counting Scale GC. User Manual SNOWREX INTERNATIONAL CO., LTD. SRGC
Precise Counting Scale GC User Manual SNOWREX INTERNATIONAL CO., LTD. SRGC 20100415 Table of Contents Table of Contents...1 Specifications... 2 Basic specification... 2 Series specification(ec TYPE/OIML
More informationLCR METER OPERATION MANUAL. Model : LCR Hz 120 Hz 1 KHz 10 KHz 100 KHz, Precision
100 Hz 120 Hz 1 KHz 10 KHz 100 KHz, Precision LCR METER Model : LCR-9183 Your purchase of this LCR METER marks a step forward for you into the field of precision measurement. Although this LCR METER is
More information8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE
8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE TRANSMILLE LTD. Version 1.1 : Apr 2015 TABLE OF CONTENTS PREPARING FOR CALIBRATION... 4 INTRODUCTION... 4 CALIBRATION INTERVAL SELECTION...
More informationThree phase sine wave inverter - 3KVA to 30KVA
Three phase sine wave inverter - 3KVA to 30KVA MEDI has designed and developed DSP based three phase / single phase sine wave inverter. This inverter can be used for the following applications 1. Offline
More informationConnect + compatible
Connect + compatible Looking for a quick setup up guide? There is lots of useful information in this book, but if all you are after is quick set up look for the following headings in this book 1) Setting
More informationMANUAL PCE-UT232
www.pce-group-europe.com PCE- Deutschland Gmb H & Co. KG Tel: +49 029 03 976 99-0 Fax: +49 029 03 976 99-29 info@warensortiment.de www.warensortiment.de PCE Group Ibérica S.L. Tel: +34 967 543 548 Fax:
More informationPOWER ANALYZER OPERATION MANUAL. Model : DW-6090A
POWER ANALYZER Model : DW-6090A Your purchase of this POWER ANALYZER marks a step forward for you into the field of precision measurement. Although this POWER ANALYZER is a complex and delicate instrument,
More informationModel # PCYFC-10kW-250A PCYFC-20kW-250A PowerCycle Battery Conditioner Operation Manual
Model # PCYFC-10kW-250A PCYFC-20kW-250A PowerCycle Battery Conditioner Operation Manual MAN-000014-00 REV. B TABLE OF CONTENTS SPECIFICATIONS... 1 CYCLER CONTROLS AND USER INTERFACE... 3 OPERATING PROCEDURE...
More informationWLDS-10 Mk3 MAJOR WATER LEAK DETECTION SYSTEM INSTALLATION & COMMISSIONING
WLDS-10 Mk3 MAJOR WATER LEAK DETECTION SYSTEM INSTALLATION & COMMISSIONING DESCRIPTION: An electronic control panel used in conjunction with one pulse meter (a water meter with pulse output proportional
More informationMODEL: D03128 CLAMP METER
MODEL: D03128 CLAMP METER 1 CONTENTS Page Number Details 3 Important Safety Information 3 Features 4 Product Overview 5 Switches, Buttons & Input Jacks 5 LCD 6 Specifications 6 Electrical Specifications
More informationFX-CM. HQ Color Mark Sensor. Model Number Legend SALIENT FEATURES. Sensors. Proximity. Photoelectric. Sensors
HQ Color Mark Sensor SALIENT FEATURES 18mm ±2mm Pushbutton Teach RGB LED light source 8 Remote Memory Setting Shock Resistant casing - 50G Model Number Legend 1 2 3 4 5 1. Series 4. Output FX 2. Type CM:
More informationOWNERS MANUAL FOR STERLING SERIES CONTROLLERS
OWNERS MANUAL FOR STERLING SERIES CONTROLLERS 24950 AVENUE KEARNY, VALENCIA, CALIFORNIA 91355-2142 PHONE (661) 257-3533 FAX (661) 257-9472 TABLE OF CONTENTS Selecting the Location for the Controller...3
More informationRF/High Frequency Meter HF-A3G
RF/High Frequency Meter HB4HFA3G0000 Contents 1 Introduction... 1 2 Application... 1 3 Features... 1 4 Identifying Parts... 2 5 Measurement Procedures... 3 6 Specifications... 5 7 Battery replacement...
More informationCM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH
AC/DC LOW CURRENT CLAMP-ON METER CM605 ENGLISH User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments
More informationDIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL- KM 2782 / 2782-T
DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL- KM 2782 / 2782-T KM 2782 V 400A POWER G 17,Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA. Sales Direct : (022) 24156638 Tel. :
More informationRADIONICS 5501 / o PERIMETER o INTERIOR o o o o o o o o o INSTANT AC CMD
RADIONICS 5501 / 4112 o PERIMETER o INTERIOR o o o o o o o o o INSTANT 1 2 3 4 5 6 AC CMD ALL Instant Delay [ 1 ] [ 2 ] [ 3 ] [ 4 ] [ 5 ] [ 6 ] [ 7 ] [ 8 ] [ 9 ] [ 0 ] [ COMMAND ] [ A ] [ B ] [ ENTER ]
More informationModel φ/1φ Power Clamp-on Meter
User's Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 382075 Product Page Model 382075 3φ/1φ Power Clamp-on
More informationHeat meter Q heat 5 US
Heat meter Q heat 5 US Ultrasonic heat meter with ultrasonic measurement technology (runtime difference method) with IrDA interface and an interface for retrofitting external modules. Exact measurement
More informationSONOMETER TM 1100 Ultrasonic compact energy meter
Data sheet SONOMETER TM 1100 Ultrasonic compact energy meter Description/Application MID examination certificate no. : DE-10-MI004-PTB003 The SONOMETER 1100 is an ultrasonic static compact energy meter
More informationME371, MT371 Single- and Three-phase electronic meters with built-in DLC communication channel
Energy Measurement and Management ME371, MT371 Single- and Three-phase electronic meters with built-in DLC communication channel ME372, MT372 Single- and Three-phase electronic meters with built-in GSM/GPRS
More informationContents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.
Contents 1. General instructions. 1.1 Precautions safety measures... 1.2 Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.2 LCD Display 2.3 Keypad. 3. Function description. 3.1
More information( F L O W I Z F A M I L Y )
THE MOST ACCURATE BATTERY POWERED SYSTEM ( F L O W I Z F A M I L Y ) E l e c t r o m a g n e t i c c o n v e r t e r p o w e r e d b y b a t t e r i e s, s o l a r p a n e l o r D C p o w e r w i t h 4
More informationDigiair Pro ATSC USER MANUAL
Digiair Pro ATSC USER MANUAL Content: DIGIAIR PRO Description 2 1 GETTING STARTED 3 1.1 POWER ON/OFF 3 1.2 POWER SUPPLY AND BATTERY 3 1.3 HOW TO USE THE METER 3 ATTENUATOR 4 DIGITAL MODE 4 2 DESCRIPTION
More informationEnergy Management Energy Analyzer Type EM270-72D
Energy Management Energy Analyzer Type EM270-72D RS485 dual port for daisy chain connection (optional) 2 programmable pulsating outputs (optional) Easy connections management (selectable) disabled by default
More informationDisclaimers. Important Notice
Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,
More informationHAWK5000 Operators Manual
HAWK5000 Operators Manual Keison Products P.O. Box 2124, Chelmsford CM1 3UP, England Tel: +44 (0) 1245 600560 Fax: +44 (0) 1245 600030 Email: sales@keison.co.uk www.keison.co.uk KANE INTERNATIONAL LIMITED
More informationWLDS-10 Mk2 MAJOR WATER LEAK DETECTION SYSTEM INSTALLATION & COMMISSIONING
WLDS-10 Mk2 MAJOR WATER LEAK DETECTION SYSTEM INSTALLATION & COMMISSIONING DESCRIPTION: An electronic control panel used in conjunction with one pulse meter (a water meter with pulse output proportional
More informationVibration Measurement Instruments VIBER X2. Manual. Ver. 2.5 Refers to VIBER X2 rev: 1.7 Software 5.0
VIBER X2 Manual Ver. 2.5 Refers to VIBER X2 rev: 1.7 Software 5.0 Our Our X x-series of hand-held instrument VIBER VIBER X1 VIBER VIBER X2 X2 VIBER X3 VIBER X3 VIBER X5 1 Vibration measurements in progress
More information