Accuracy : ± (0.8% rdg + 1dgt) on all ranges except Ranges : 200mV, 2V, 20V, 200V, 1000V
|
|
- Belinda Gregory
- 5 years ago
- Views:
Transcription
1 . SPECIFICATIONS Digital Multimeter Model : 0 Instruction Manual. General Specifications Display : ½ digit liquid crystal display (LCD) with a maximum reading of 999. Polarity : Automatic, (-)negative polarity indication Zero adjustment : Automatic Overrange indication : Highest digit of() or (-) is diplayed at MSD Low battery : is displayed when the battery voltage drops below the operating voltage Measurement rate : measurements per second, nominal. Operating conditions : 0 C to + 0 C at < 7% RH Storage conditions : -0 C to + 0 C, 0-80% RH with battery removed. : specifications at ± C, less than 7% RH. Power Supply : Single, standard 9-volt battery, Eveready or equivalent. Battery life (typical) : 00 hours. Dimensions : 70 x 80 x 8 mm. (approx.) Weight : 0gms including battery (approx.) Accessories : Test leads (pair) x, spare fuse 0.8A/ 0V x, battery (installed) x, instruction manual x & carring case x. Electrical Specifications Accuracies are ± (% reading plus number of digits) at ± C, and humidity of less than 7% RH. RESISTANCE s : 00V, KV, 0KV, 00KV, 000KV, 0MV, 00MV. DC VOLTAGE : ± (0.8% rdg + dgt) on all ranges except s : 00mV, V, 0V, 00V, 000V ± (% rdg + dgt) on 00V : ±(0.%rdg + dgt) on all ranges. ± (% rdg + dgt) on 0MV Resolution : 00μV to V ± (% rdg + 0 dgt) on 00MV Input Impedance : 0MV Resolution : 00mV to 00KV Overload Protection : 00V DC/0VAC for sec. on 00mV Overload Protection : 00V DC/AC range, 00V DC/800V AC on all other Test Voltage : 00V, 00MV :.V MAX. ranges. Other ranges 0.V MAX. AC VOLTAGE (0-00Hz) CONTINUITY BEEPER s : 00mV, V, 0V, 00V, 70V Threshold : 00V approx. : ± (% rdg + dgt) on all ranges except Response Time : 00mS ±(.% rdg + dgt) on 70V h FE Test Resolution : 00μV to V Base DC Current : 0 ma Input Impedance : 0MV V CE :.8 ± 0.V Overload Protection : 00V DC/0VAC for sec. on 00mV range, 00V DC/800V AC on all other : 0 To 000 ranges. Diode Test DC CURRENT Test Current :.0 ± 0.mA s : 00mA, ma, 0mA, 00mA, 0A Test Voltage :.V max. (In 0A range maximum measuring time. OPERATION < 0s with an interval of minutes.). VOLTAGE MEASUREMENT : ± (% rdg + dgt) on all ranges except. Connect red test lead to V-V input terminal and black test lead to ±(% rdg + dgt) on 0A range COM input terminal. Resolution : 00nA to 0mA. Set Function/ switch to desired voltage type (DC or AC) and Voltage Burden : mv except,.v max. on 0A range range. If magnitude of voltage is not known, set switch to the highest Overload Protection : 0.8A/0V FUSED. on all ranges except range and reduce until a satisfactory reading is obtained. A unfused for 0 sec. on 0A range. Turn off power to the device or circuit being tested and discharge all AC CURRENT (0-00Hz) capacitors. s : 00mA, ma, 0mA, 00mA, 0A. Connect test leads to the device or circuit being measured. (In 0A range maximum measuring time. Turn on power to the device or circuit being measured. Voltage value < 0s with an interval of minutes.) will appear on the digital display along with the voltage polarity. : ± (.% rdg + dgt) on all ranges except ±(% rdg + dgt) on 0A range. Turn off power to the device or circuit being tested and discharge all capacitors prior to disconnecting test leads. Resolution : 00nA to 0mA. CURRENT MEASUREMENT Voltage Burden Overload Protection : : mv except,.v max. on 0A range 0.8A/0V FUSED on all ranges except. Connect red test lead to the ma input terminal for current measurements up to 00 milliamperes. Connect black lead to the COM A unfused for 0 sec. on 0A range input terminal. 0 :
2 . Set Function/ switch to desired current type (DC or AC) and range. If magnitude of current is not known, set switch to the highest range and reduce until a satisfactory reading is obtained.. Turn off power to the device or circuit being tested and discharge all capacitors.. Open the circuit in which current is to be measured. Now securely connect test leads in series with the load in which current is to be measured.. Turn on power to the device or circuit being tested.. Read current value on digital display. 7. Turn off all power to the device or circuit being tested and discharge all capacitors. 8. Disconnect test leads from circuit and reconnect circuit that was being tested. 9. For current measurment of 00mA or greater, connect the red test lead to 0 A input terminal & black test lest lead to the COM input terminal. If the resistance being measured is part of a circuit, turn off power to the circuit and discharge all capacitors.. RESISTANCE MEASUREMENTS. Connect red test lead to V-V input terminal and black test lead to COM input terminal.. Set Function/ switch to desired V position. If magnitude of resistance is not known, set the switch to highest range and reduce until a satisfactory reading is obtained.. If the resistance being measured is part of a circuit, turn off power to the circuit and discharge all capacitors.. Connect test leads to the device or circuit being measured. When measuring high resistance, be sure not to contact adjacent points even if insulated, because some insulators have a relatively low insulation resistance, causing the measured resistance to be lower than the actual resistance.. Read resistance value on digital display. If a high resistance value is shunted by a large value of capacitance, allow digits to stabilize. NOTE A. All resistance ranges on the DMM, except the 00V and 00MV range, are low-power ohms. This allows accurate measurements of in-circuit resistance because the test voltage is below that is necessary to activate a diode junction B. The 00MV range has a fixed 0-count off set in its reading. When the test leads are shorted together in this range, the meter will display 00 in the 00MV range. This reading must be subtracted in order to obtain a true measurement. For example, when measuring a resistance of 00MV on the 00MV range, the display will read 0.. DIODE AND TRANSISTOR TEST MEASUREMENTS The special Diode Test Function allows relative measurements of forward voltage drops across diodes and transistor junctions. This function also permits measurement of in-circuit semiconductor junctions... DIODE TESTS. Connect red test lead to V-V input terminal and black test lead to COM input terminal.. Set Function/ switch to the diode test position.. If the semiconductor junction being measured is part of to a circuit, turn off power to the circuit and discharge all capacitors.. Connect test leads to the device.. Read forward voltage drop value on digital display.. If the digital display reads overrange () reverse the lead connections. The placement of the test leads when the forward reading is displayed indicates the orientation of the diode. The red lead is positive and the black lead is negative. if overrange () is displayed with both lead connections, the junction is open. If a low-reading (less than,000) is obtained with both lead connections, the junction is shorted internally or (if junction is measured in a circuit) the junction is shunted by a resistance less than KV. In the latter case the junction must be disconnected from the circuit in order to verify its operation... TRANSISTOR JUNCTION TESTS. Bipolar transistors can be tested in the same manner as diode, junctions formed between the base and emitter and the base and collector of the transistor. Measurement between the collector and emitter also should be made to determine if a short is present.. TRANSISTOR hfe MEASUREMENTS. Transistor must be out of circuit. Set the function/range switch to the hfe position.. Plug the emitter, base and collector leads of the transistor into the correct holes in either the NPN or the PNP transistor test socket, whichever is appropriate for the transistor being checked. Read the hfe (beta, or DC current gain) in the display.. CONTINUITY MEASUREMENTS. Set the selectors switch to the ))) position.. Continuity between probe tips will be indicated by an audible beep when resistance is below 00V.. MAINTENANCE. TROUBLESHOOTING If there appears to be a malfunction during the operation of the meter, the following steps should be performed in order to isolate the cause of the problem:. Check the battery.. Review the operating instructions for possible mistakes in operating procedure.. Inspect and test the Test Probes for a broken or intermittent connection.. Inspect and test the fuse. If it is necessary to replace the fuse, be sure to install one of the proper current rating.. BATTERY AND FUSE REPLACEMENT To prevent electrical shock hazard, turn off the multimeter and any device or circuit under test and disconnect the test leads before removing the battery snap or the rear cover. a. BATTERY REPLACEMENT. Remove the battery cover screw, and slide the battery cover towards the bottom of the meter.. Remove and disconnect the old battery from the meter and replace with a new unit. Wind the excess lead length once around the battery clip. Install the battery and replace the battery cover. CAUTION Failure to turn off the multimeter before installing the battery could result in damage to the instrument and to the battery if the battery is connected incorrectly to the multimeter. b. FUSE REPLACEMENT. Remove the battery cover screw, and slide the battery cover towards the bottom of the meter.. Remove the old fuse and replace with a new fuse rated for 0.8 amps. 0 volts. Use of wrong fuse could result in serious accident. CERTIFICATE OF CALIBRATION We hereby certify that this product has been calibrated and found to be in accordance with the applicable SPECIFICATIONS and MECO STANDARDS. Accuracies of the standard equipment used in this calibration are traceable to the National Standards. MECO METERS PVT. LTD. Plot No. EL-0, MIDC Electronic Zone, TTC Industrial Area, Mahape, Navi Mumbai (INDIA) Tel : , 7700 (Board) Fax : , sales@mecoinst.com Web : SR. NO. : CHECKED BY : DATE : 7 MODEL NO. : 8 0 :
3 AUTORANGING DIGITAL MULTIMETER MODEL : 9A0 FRONT PANEL CONTROLS INSTRUCTION MANUAL. LCD Display. Hold Switch. Switch. Power ON / OFF Switch. Select Switch V/ / / AC-DC / C- F. Function Switch 7. 0A Input Jack 8. μa / ma / Temp (+) Input Jack 9. Common / Temp (-) Input Jack 0. V / V / / Input Jack Getting Acquainted With Your Meter LCD Display Illustration AUTO AC DC M.H mv V ma ma A V kv MV 0 C 0 F Low Battery Indication Auto Mode Alternating Current or Voltage Direct Current or Voltage Digital Display for Reading Diode Measurement Mode Continuity Mode Manual Hold Voltage Measurement Current Measurement Resistance Measurement Centigrade / Fahrenheit Temperature Measurement 7 8 9, 0. SPECIFICATIONS. General Specifications Display / digit liquid crystal display (LCD).0 mm height, max. reading 999 with automatic decimal point selection annunciators of mv, V, μa, ma, A, V, KV, MV,,, AC, DC, 0 C, 0 F, MH, AUTO, Selection Auto & Manual for Voltage, Resistance, μa, ma & A measurement. Polarity Automatic, ( - ) negative polarity indication. Zero adjustment Automatic Over range indication OL is displayd except in 000VDC, 70VAC & 0A AC/DC range. Low battery mark turns on. Sample rate measurement per second. Operating conditions 0 C to + 0 C at > 7% RH (Noncondensing) Storage conditions -0 C to + 0 C, 0-80% RH with battery removed specificaton at 7 ± C and less than 7% RH. Power Supply Two, standard,.v battery. Eveready 0 or equivalent. Battery life (typical) 00 hours Dimensions x 8 x mm (approx.) Weight 7gms including battery (approx.) Accessories Test leads (pair) x, carring case x, battery (installed) x, Instruction Manual x & K type Thermocouple x LCD DISPLAY 9A0 9A0 :
4 . Electrical Specification Accuracies are ± (% reading plus number of digits) at 7 ± C and humidity of less than 7% RH. DC VOLTAGE (Auto & Manual Ranging) s : 00mV, V, 0V, 00V, 000V : ± (0.% rdg + dgt) on 00mV & V ± (0.7% rdg + dgt) on 0V & 00V ± (% of rdg + dgt) on 000V Resolution : 00μV to V Input Impedance : 0MV on all ranges except, > 0MV on 00mV MV on V Overload Protection : 00V DC/0V AC for sec. on 00mV range, 00V DC/800V AC on all other range. AC VOLTAGE (Auto & Manual Ranging) 0-00Hz : 00mV, V, 0V, 00V, 70V (00mv range manual only) : ± (.0% rdg + 8 dgt) on all ranges except, ± (.% rdg + 8 dgt) on 70V Resolution : mv to V Input Impedance : 0MV on all ranges except, MV on V Overload Protection : 00V DC/800V AC on all ranges. DC CURRENT (Auto & Manual Ranging) : 00μA, 000μA, 0mA, 00mA, 0A : ± (.% rdg + dgt) on all ranges Resolution : 00μA to 0mA Burden Voltage : mv max on all ranges except, 70mV max on 0A range. Overload Protection : 0.A / 0V fused on all ranges except, 0A / 00V fused on 0A AC CURRENT (Auto & Manual Ranging) 0-00Hz : 00μA, 000μA, 0mA, 00mA, 0A : ± (.% rdg + dgt) on all ranges Resolution : 00μA to 0mA Burden Voltage : mv max on all ranges except, 70mV max on 0A range. Overload Protection : 0.A / 0V fused on all ranges. 0A / 00V fuse on 0A RESISTANCE (Auto & Manual Ranging) : 00V, KV, 0KV, 00KV, MV, 0MV : ± (0.7% rdg + dgt) on all ranges except ± (.% of rdg + dgt) on MV ± (.% of rdg + dgt) on 0MV Resolution : 0.V to 0KV Test Current : 0.7mA on 00V, 0.mA on KV, 0μA on 0KV, μa on 00KV Overload Protection : 00V DC/AC Continuity Check Threshold Level : 0V Approx. Response Time : m Sec. Approx. Open Circuit Voltage : 0.V Approx. Indication : is displayed on LCD and buzzer sounds at continuity. Diode Test Measurement Current :.0 ± 0. ma Approx. Open Circuit Voltage :.V Approx. Temperature : -0 0 C to 00 0 C - 0 F to F : ± (.0% rdg + dgt) Resolution : 0 C Sensor : K Type Thermocouple. OPERATION MEASUREMENT PROCEDURE SWITCH OPERATION (A) POWER SWITCH POWER switch enables to switch on the power to the meter. (B) V / / / AC - DC / 0 C- 0 F SELECT SWITCH The switch is used for Current,Resistance & Temperature measurement. (a) In current measurement initially DC value is measured & DC is displayed on LCD. To measure AC value press SELECT switch. The display will change from DC to AC. Again switch over to DC press the switch once more. (b) In resistance measurement the switch is used to change over between V / / measurement. (c) In temperature measurement the switch is used to change over 0 C- 0 F measurement. The corrosponding annunciator will be displayed. (C) RANGE SWITCH RANGE switch is used to operate the meter in MANUAL mode. The present range of the meter will be increased by pressing the RANGE switch. To come out of manual mode press RANGE switch for approx seconds. The meter will operate in AUTO mode again and AUTO will be displayed on LCD. (D) HOLD SWITCH When HOLD switch is pressed the present data is locked and MH symbol appears on LCD. When HOLD switch is pressed again, the meter functions normally and MH sign disappears. BUZZER It sounds when operating SELECT switch, HOLD switch and RANGE switch. It sounds for less than threshold level in continuity function. AUTO POWER OFF The meter will be switched off if no Function switch or key is used for approx minutes. To restart press hold key.. VOLTAGE MEASUREMENTS (DC/AC). Connect red test lead to ` V input terminal and black test lead to COM input terminal.. Set the function switch to (DCV or ACV) position.. Connect test lead to the device or circuit being measured.. Turn on power to the device or circuit being measured voltage value will appear on the digital display along with the voltage polarity.. Turn off power to the device or circuit being tested and discharge all capacitors prior to disconnecting test lead.. CURRENT MEASUREMENTS (DC/AC). Switch on the multimeter by pressing POWER switch.. Connect red test lead to the μa / ma input terminal for current measurements up to 00 milliamperes. Connect black test lead to the COM input terminal. For current greater than 00mA, connect red test lead to `A terminal.. Set Function switch to μa, ma & A as per measurement. If the range of current to be measured is not known, start from the higher range ie. `A and change range as required.. Select DC or AC by Pressing SELECT Switch.. Open the circuit in which current is to be measured. Now securely connect test leads in series with the load in which current is to be measured A0 :
5 . Turn on power to the device or circuit being tested. 7. Read current value on digital display. 8. Turn off all power to the device or circuit being tested and discharge all capacitors. 9. Disconnect test leads from circuit & reconnect circuit that was being tested.. RESISTANCE MEASUREMENTS. Switch on the multimeter by pressing POWER switch.. Connect red test lead to V input terminal and black test lead to COM input terminal.. Set the Function Switch to V position.. If the resistance being measured is part of a circuit, turn off power to the circuit and discharge all capacitors.. Connect test leads to the device or circuit being measured. When measuring high resistance, be sure not to contact adjacent points even if insulated, because some insulators have a relatively low insulation resistance, causing the measured resistance to be lower than the actual resistance. Read resistance value on digital display. If a high resistance value is shunted by large value of capacitance, allow digits to stabilize. NOTE : While measuring high resistance value more than one megohms, the digital reading is liable to receive the influence of noise, or of some insulators that have a relatively low insulation resistance. Therefore to make accurate measurements guard-shield is recommended. Black test leads is connected to the negative side.. DIODE & CONTINUITY. Switch on the meter by pressing POWER switch.. Set FUNCTION switch to V position.. A. Diode Check. Press SELECT switch once, will be displayed.. Connect black test lead to the cathode side and red test lead to the anode side of the semiconductor. Display reading is forward voltage.. Connect the test leads in reverse of above. If the display reading is same as when the leads are open, the semiconductor is good, otherwise it is defective. Note : This test is influenced by the other devices connected to the diode. Hence isolate it before testing.. B. Continuity. Press SELECT switch once will be displayed.. Insert black test lead into COM terminal and red test lead to V Terminal.. Remove power from the circuit being tested and discharge all capacitors.. Connect the test leads to the circuit being measured. If resistance value is lower than 0V, buzzer sounds. Note : Continuity test is to check continuity of the circuit. If precise data of resistance is needed, use V function.. TEMPERATURE MEASUREMENT. Switch on the multimeter by pressing POWER switch.. Set function switch to TEMP position.. Connect Red probe of K type thermocouple to ma / ma / TEMP ( + ) terminal and Black probe to COM / TEMP ( - ) terminal.. Touch the end of temperature probe to the area or serface of the object whose temperature is to be measured. The display reading is in 0 C.. Press SELECT switch to measure reading in 0 F scale. 9 0 IMPORTANT To avoid heat damage to the meter, keep it away from sources of very high temperature. The life of the temperature probe is also reduced when subjected to very high temperatures. ( Operating is 0 to 00 C ). MAINTENANCE WARNING: Remove test leads before changing batteries or fuse or performing any servicing. Never operate instrument unless bottom cover is closed.. TROUBLESHOOTING If there appears to be a malfunction during the operation of the meter, the following steps should be performed in order to isolate the cause of the problem:. Check the battery.. Review the operating instructions for possible mistakes in operating procedure.. Inspect and test the Test Probes for a broken or intermittent connection.. Inspect and test the fuse. If it is necessary to replace the fuse, be sure to install one of the proper current rating.. BATTERY AND FUSE REPLACEMENT To prevent electrical shock hazard, turn off the multimeter and any device or circuit under test and disconnect the test leads before removing the bottom cover. Digram A 9A0 :
6 A. BATTERY REPLACEMENT (Refer Diagram `A ) sign in display indicates LOW BATTERY. There are about 0 hours of operation left after first appears. Open the bottom cover and replace with two fresh.v Eveready type 0 or equivalent batterys, observing polarity as marked. Incorrect polarity will cause display to remain blank. To prolong battery life, Switch OFF the POWER when not making measurement. B. FUSE REPLACEMENT (Refer Diagram A ) If no current measurements is possible, check for blown overload protection fuse. Open the bottom cover to the locate the fuse. Replace only with original type of fuse.. PRECAUTIONS. Observe all safety rules while making measurements. CAUTION should be exercised when making measurements since dangerous voltages can be present in normally safe circuit or areas.. Although this instrument is electronically and fuse protected against overloads, care should be taken to avoid excessive and repeated overloads when possible.. It is normal for this instrument digits to wander when on the mv range, since the DC input impedance is a very high. This high input impedance is needed when making accurate low voltage measurements.. If this instrument is NOT going to be operated for an extended period, remove the batteries since damage can result from leakage.. SAFETY RULES WARNING An electrical shock causing 0 miliamps of current to pass through the heart will stop most human heartbeats. Voltage as low as Volts DC or AC rms should be considered dangerous and hazardous since it can produce a fatal current under certain conditions. Higher voltage are even more dangerous. Observe the following safety precautions.. Do not exceed the following input ratings. Personal injury or damage to the instrument may result. DC VOLTS V (DC + AC peak) AC VOLTS... 70V rms OHMS... 0V rms ma... 00mA (fuse protected) 0A... 0A (fuse protected) COM... Do not float more than 000 volts from earth ground.. Always check to make sure test lead plugs are fully inserted into input terminals and the function / range selector switch is set to the proper position.. Never use the multimeter unless the bottom cover is closed.. Remove test leads before replacing battery or fuses, and before performing any servicing on the multimeter.. Turn off equipment while making test connections in high voltage circuits. Discharge high-voltage capacitors after removing power.. For the safest voltage or current measurements in high voltage equipment, do not touch equipment, meter, or test leads while power is applied. 7. If possible, familiarize yourself with the equipment being tested and the location of its high voltage points. However, remember that high voltage may appear at unexpected points in defective equipment. Use an insulated floor material or floor mat to stand on and an insulated work bench surface; make certain such surfaces are not damp or wet. CERTIFICATE OF CALIBRATION We hereby certify that this product has been calibrated and found to be in accordance with the applicable SPECIFICATIONS and MECO STANDARDS. Accuracies of the standard equipment used in this calibration are traceable to the National Standards. MECO METERS PVT. LTD. Plot No. EL-0, MIDC Electronic Zone, TTC Industrial Area, Mahape, Navi Mumbai (INDIA) Tel : , 7700 (Board) Fax : , sales@mecoinst.com Web : SR. NO CHECKED BY DATE MODEL NO : : : : 9A0 :
7 FRONT PANEL CONTROLS AUTORANGING DIGITAL MULTIMETER MODEL : 80AUTO INSTRUCTION MANUAL. LCD Display. REL Switch. Switch. Power ON / OFF Switch. V / / / / AC-DC Select Switch. Hold Switch 7. Hz / Duty Switch 8. Function Switch 9. 0A Input Jack 0. μa / ma / Temp+ Input Jack. Common / Temp- / C- Input Jack. V / V / / / C+ Input Jack Getting Acquainted With Your Meter LCD Display Illustration. SPECIFICATIONS Digital Display for Reading. General Specifications Display 999 counts liquid crystal display (LCD) DC Direct Current or Voltage.0mm height, max. reading 999, AC Alternating Current or automatic decimal points selection and Voltage annunciators of mv, V, μa, ma, A, V, KV, MV, AC, DC,, AUTO,, KHz, MHz,, AUTO Auto Mode nf, μf, H, O C, % Manual Zero in Capacitance Selection Auto & Manual for DC, AC Voltage, Measurement Resistance, μa, ma & A measurement H Data Hold Auto only for Frequency, capacitance, Temperature measurement 7 Low Battery Indication Polarity Automatic, (-) negative polarity indication 8 Diode Measurement Mode Zero adjustment Automatic for all ranges except 9 Continuity Mode capacitance (manual zero) 0 kmv Resistance Measurement Over range indication OL is displayed except in 000V DC, 70V AC and 0A AC/DC range kmhz Frequency Measurement Low battery mark turns on nmf Capacitance Measurement Sample rate measurement per second mv Voltage Measurement Operating conditions 0 C to +0 C, 0-7% RH mma Current Measurement (Noncondensing) Storage conditions -0 C to +0 C, 0-80% RH with O C Temperature Measurement battery removed % Duty Cycle Measurement specification at 7 ± C and less than 7% RH Power Supply Two Standard.V battery % H 0 C Eveready type 0 or equivalent Battery life (typical) 00 hours 0 Dimensions x 8 x mm (approx.), Weight 7gms including battery (approx.), Accessories Test leads (pair) x, carring case x, battery (installed) x, Instructional LCD DISPLAY 80AUTO manual x & K Type Thermocouple x 80AUTO :
8 . Electrical Specification Accuracies are ± (% reading + number of digits) at 7 ± C and humidity of less than 7% RH DC VOLTAGE (Auto & Manual Ranging) : 00mV, V, 0V, 00V, 000V : ± (0.% rdg + dgt) on 00mV & V ± (0.7% rdg + dgt) on 0V & 00V ± (.0% rdg + dgt) on 000V Resolution : 0.mV tov Input Impedance : 0MV on all ranges Overload Protection : 00V DC / 0V AC for sec. on 00mV, 00V DC / 800V AC on all ranges AC VOLTAGE (Auto & Manual Ranging) 0-00Hz : V, 0V, 00V, 70V : ± (.0% rdg + dgt) on all ranges except, ± (.% rdg + 8 dgt) on 70V Resolution : mv to V Input Impedance : 0MV on all ranges Overload Protection : 00V DC / 800V AC on all ranges DC CURRENT (Auto & Manual Ranging) : 00μA, 000μA, 0mA, 00mA, A, 0A : ± (.% rdg + dgt) Resolution : 0.μA to 0.0A Burden Voltage : < 0.7V on 00mA < 0.V on 0A Overload Protection : 0.A / 0V fuse on 00mA 0A / 00V fuse on 0A AC CURRENT (Auto & Manual Ranging) 0-00Hz : 00μA, 000μA, 0mA, 00mA, A, 0A : ± (.% rdg + dgt) Resolution : 0.μA to 0.0A Burden Voltage : < 0.7V on 00mA < 0.V on 0A Overload Protection : 0.A / 0V fuse on 00mA 0A / 00V fuse on 0A RESISTANCE (Auto & Manual Ranging) : 00V, KV, 0KV, 00KV, MV, 0MV, : ± (0.7% rdg + dgt) on all ranges except ± (.% rdg + dgt) on MV, ± (.% rdg + dgt) on 0MV Resolution : 0.V to 0.0MV Test Current : Approx 0.7mA on 00V, 0.mA on KV, 0μA on 0KV, μa on 00KV Overload Protection : 00V DC/AC FREQUENCY (Auto Ranging) : 9.999Hz, 99.99Hz, 999.9Hz, 9.999kHz, 99.99kHz, 999.9kHz, 9.999MHz : ± (0.% rdg + dgt) % DUTY CYCLE (Auto Ranging) : 0.% to 99.9% : ± (0.% rdg + dgt) Resolution : 0.% CAPACITANCE (Auto Ranging) : 0nF, 00nF, μf, 0μF, 00μF : ± (.0% rdg + 0 dgt) Resolution : pf to 0.0nF TEMPERATURE : -0 O C ~ 00 O C : ± (.0% rdg + dgt) Resolution : O C Sensor : K Type Thermocouple CONTINUITY CHECK b) In resistance measuement this switch is used to change over Threshold Level : 70V Approx. between V,,, measurement. The corresponding annunciator Response Time : m Sec. Approx. will be displayed on LCD. Open Circuit Voltage : 0.V Approx. (E) HOLD SWITCH Indication : is displayed on LCD and buzzer When HOLD switch is pressed, the present data is locked and symbol sounds at continuity i H Iappears on LCD. When HOLD switch is pressed again the meter DIODE TEST functions normally & sign disappears. Measurement Current :.0 ± 0. ma Approx. Open Circuit Voltage :.V Approx. (F) HZ / DUTY SWITCH Press this key to toggle between frequency & duty cycle measurement.. OPERATION BUZZER It sounds when operating SELECT Switch, REL / Switch, MEASUREMENT PROCEDURE Switch, Hold Switch & Hz / Duty Switch. SWITCH OPERATION It sounds for less than threshold level in continuity function. (A) POWER SWITCH AUTO POWER OFF POWER switch enables to switch on the power to the meter. By default, the meter is in auto power off mode. In this mode, the meter (B) REL / SWITCH will be switched off after minutes, if no range change is done. If this Press (REL / ) switch to enter the Relative mode. The annunciator mode is not required, press the select key along with power on key. The turns on. The display reading is stored as a referance value and the auto power off mode will be turned off. display becomes zero. The switch is functional in capacitance range only.. VOLTAGE MEASUREMENTS (DC/AC) (C) RANGE SWITCH. Switch on the multimeter by pressing POWER switch.. Connect red test lead to V input terminal & black test lead to RANGE switch is used to operate the meter in MANUAL mode. COM input terminal. The present range of the meter will be increased by pressing the RANGE switch. To come out of manual mode, press the RANGE switch. Set the Function Switch to V position. for approx seconds. The meter will operate in AUTO mode again. Select DC or AC by pressing SELECT switch. and AUTO will be displayed on LCD.. Connect test lead to the device or circuit being measured. (D) SELECT SWITCH. Turn on power to the device or circuit being measured. Voltage value will appear on the digital display along with the voltage The switch is used for voltage, current & resistance measurement. polarity. a) In voltage and current measurement, initially DC value is measured and DC is displayed on LCD. To measure AC value, the SELECT 7. Turn off power to the device or circuit being tested and discharge switch has to be pressed once. The display will change from DC to all capacitors prior to disconnecting test lead. AC. To again switch over to DC, press the switch once more AUTO :
9 . CURRENT MEASUREMENTS (DC/AC). Switch on the multimeter by pressing POWER switch.. Connect red test lead to the μa / ma input terminal for current measurements up to 00 milliamperes. Connect black test lead to the COM input terminal.. For current measurement of 00mA or greater, connect the red test lead to 0A input terminal & black test lead to the COM input terminal. Set function switch to A position.. Set Function Switch to μa for μa measurement ma for ma measurement and A for A measurement. Do not keep the Meter in the circuit for more than seconds when the function switch is on A range.. Select DC or AC by Pressing SELECT Switch.. Open the circuit in which current is to be measured. Now securely connect test leads in series with the load in which current is to be measured. 7. Turn on power to the device or circuit being tested. 8. Read current value on digital display. 9. Turn off all power to the device or circuit being tested and discharge all capacitors. 0. Disconnect test leads from circuit & reconnect circuit that was being tested.. RESISTANCE MEASUREMENTS. Switch on the multimeter by pressing POWER switch.. Connect red test lead to V input terminal and black test lead to COM input terminal.. Set the Function Switch to V position.. If the resistance being measured is part of a circuit, turn off power to the circuit and discharge all capacitors.. Connect test leads to the device or circuit being measured. When measuring high resistance, be sure not to contact adjacent points even if insulated, because some insulators have a relatively low insulation resistance, causing the measured resistance to be lower than the actual resistance. 9. Read resistance value on digital display. If a high resistance value is shunted by large value of capacitance, allow digits to stabilize. NOTE : While measuring high resistance value more than one megohms, the digital reading is liable to receive the influence of noise, or of some insulators that have a relatively low insulation resistance. Therefore to make accurate measurements guard-shield is recommended. Black test leads is connected to the negative side.. DIODE, CONTINUITY & CAPACITANCE MEASUREMENT. Switch on the meter by pressing POWER switch.. Set Function Switch to V position.. A. Diode Check. Press SELECT switch once, will be displayed.. Connect black test lead to the cathode side and red test lead to the anode side of the semiconductor. Display reading is forward voltage.. Connect the test leads in reverse of above. If the display reading is same as when the leads are open, the semiconductor is good, otherwise it is defective. Note : This test is influenced by the other devices connected to the diode. Hence isolate it before testing.. B. Continuity. Press SELECT swtich once will be displayed.. Insert red test lead to V terminal & black test lead to COM terminal.. Remove power from the circuit being tested and discharge all capacitors.. Connect the test leads to the circuit being measured. If resistance value is lower than 70V, buzzer sounds. Note : Continuity test is to check continuity of the circuit. If precise data of resistance is needed, use V function.. C. Capacitance Measurement. Press SELECT swtich once will be displayed.. By Pressing REL / Switch, get Zero display. Connect red test lead to C+ terminal & black test lead to C- terminal. 0. Discharge the capacitor before measuring. Connect the capacitor to the test lead for accurate measurements of low value capacitors. Connect the capacitor directly to the input terminals of the meter. Observe polarity while measureing polarised capacitors. Read capacitors value directly on the LCD.. FREQUENCY & DUTY CYCLE MEASUREMENTS Fig. Fig. There are positions for Frequency & Duty cycle measurements. a) Hz position ( Not for LINE Frequency measurement ) b) ~V position ( For LINE Frequency measurement ).a) Hz position ( Not for LINE Frequency measurement ) [Fig.] Sensitivity : 0.8V (0Hz to 00kHz) V ~ 0V (above 00kHz) Frequency : Hz to MHz Duty Cycle :.% to 99.9% Over Voltage Protect : 00V DC or AC Peak ) Switch on the multimeter by pressing Power switch. ) Connect test leads to VV & common terminal. ) Set rotary switch to Hz position. ) Select Frequency or Duty cycle by pressing Hz / Duty key. ) Connect the test leads across the source or load under measurement..b) ~V position ( For LINE Frequency measurement ) [Fig.] Sensitivity : V Frequency : 0 Hz to 00 Hz. Duty Cycle :.% to 99.9% Over Voltage Protect : 000V DC or AC Peak ) Switch on the multimeter by pressing Power switch. ) Connect test leads to VV & common terminal. ) Set rotary switch to ~V position. ) Select Frequency or Duty cycle by pressing Hz / Duty key. ) Connect the test leads across the source or load under measurement.. TEMPERATURE MEASUREMENT. Switch on the multimeter by pressing POWER switch.. Set function switch to TEMP position.. Connect Red probe of K type thermocouple to ma / ma / TEMP ( + ) terminal and Black probe to COM / TEMP ( - ) terminal.. Touch the end of temperature probe to the area or surface of the object whose temperature is to be measured. The display reading is in 0 C. Digram A 80AUTO :
10 IMPORTANT To avoid heat damage to the meter, keep it away from sources of very high temperature. The life of the temperature probe is also reduced when subjected to very high temperatures. ( Operating is 0 to 00 C ). MAINTENANCE WARNING: Remove test leads before changing batteries or fuse or performing any servicing. Never operate instrument unless bottom cover is closed.. TROUBLESHOOTING If there appears to be a malfunction during the operation of the meter, the following steps should be performed in order to isolate the cause of the problem:. Check the battery.. Review the operating instructions for possible mistakes in operating procedure.. Inspect and test the Test Probes for a broken or intermittent connection.. Inspect and test both the fuses. If it is necessary to replace the fuse, be sure to install one of the proper current rating.. BATTERY AND FUSE REPLACEMENT (Refer Diagram A ) To prevent electrical shock hazard, turn off the multimeter and any device or circuit under test and disconnect the test leads before removing the bottom cover. A. BATTERY REPLACEMENT sign in display indicates LOW BATTERY. There are about 0 hours of operation left after first appears. Open the bottom cover and replace with two fresh.v Eveready type 0 or equivalent battery, observing polarity as marked. Incorrect polarity will cause display to remain blank. To prolong battery life, Switch OFF the POWER when not making measurement. B. FUSE REPLACEMENT If no current measurement is possible, check for blown overload protection fuses. Open the bottom cover to the locate the fuse. Replace only with original type of fuse.. PRECAUTIONS. Observe all safety rules while making measurements. CAUTION should be exercised when making measurements since dangerous voltages can be present in normally safe circuit or areas.. Although this instrument is electronically and fuse protected against overloads, care should be taken to avoid excessive and repeated overloads when possible.. It is normal for this instrument digits to wander when on the mv range, since the DC input impedance is a very high. This high input impedance is needed when making accurate low voltage measurements.. If this instrument is NOT going to be operated for an extended period, remove the battery since damage can result from leakage.. SAFETY RULES WARNING An electrical shock causing 0 miliamps of current to pass through the heart will stop most human heartbeats. Voltage as low as Volts DC or AC rms should be considered dangerous and hazardous since it can produce a fatal current under certain conditions. Higher voltage are even more dangerous. Observe the following safety precautions.. Do not exceed the following input ratings. Personal injury or damage to the instrument may result. DC VOLTS V (DC + AC peak) AC VOLTS... 70V rms OHMS... 0V rms ma... 00mA (fuse protected) 0A... 0A (fuse protected) COM... Do not float more than 000 volts from earth ground.. Always check to make sure test lead plugs are fully inserted into input terminals and the function / range selector switch is set to the proper position.. Never use the multimeter unless the bottom cover is closed.. Remove test leads before replacing battery or fuses, and before performing any servicing on the multimeter.. Turn off equipment while making test connections in high voltage circuits. Discharge high-voltage capacitors after removing power.. For the safest voltage or current measurements in high voltage equipment, do not touch equipment, meter, or test leads while power is applied. 7. If possible, familiarize yourself with the equipment being tested and the location of its high voltage points. However, remember that high voltage may appear at unexpected points in defective equipment. Use an insulated floor material or floor mat to stand on and an insulated work bench surface; make certain such surfaces are not damp or wet. Certificate of Calibration We hereby certify that this product has been calibrated and found to be in accordance with the applicable SPECIFICATIONS and STANDARDS. Accuracies of the standard equipment used in this calibration are traceable to the National Standards. MECO METERS PVT. LTD. Plot No. EL-0, MIDC Electronic Zone, TTC Industrial Area, Mahape, Navi Mumbai (INDIA) Tel : , 7700 (Board) Fax : , sales@mecoinst.com Web : SR. NO. : CHECKED BY : DATE : MODEL NO. : 80AUTO :
Digital Clamp Meter (TRMS) Model : 2727
Digital Clamp Meter (TRMS) Model : 2727 Instruction Manual 1. SPECIFICATIONS 1.1 General Specifications Display : 3 ¾ digit liquid crystal display (LCD) with a maximum reading of 3999. Polarity : Automatic,
More informationDVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use
True RMS Digital Multimeter DVM98 1 Safety information This multimeter has been designed according to IEC - 1010 concerning electronic measuring instruments with an overvoltage category (CAT II) and pollution
More informationINSTRUCTION MANUAL DIGITAL MULTIMETER
INSTRUCTION MANUAL DIGITAL MULTIMETER 600 OFF 600 20 2m 2 20m m m 2M 10A k 20k 2k O C NPN PNP hfe E B C E 10A DC 10A MAX UNFUSED MAX 600V COM V ma ma MAX FUSED CAT II 600V Thanks for buying our products,
More informationEM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use
http://www.all-sun.com EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL V Read this owners manual thoroughly before use WARRANTY This instrument is warranted to be free from defects in material and workmanship
More informationModel ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com
Model ST-9933 True RMS Autoranging Digital Multimeter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-8 Technical...4-5 Accuracy...5-8 Display Description...
More informationM-1000D DIGITAL MULTIMETER
OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER M-1000D Elenco Electronics, Inc. 150 Carpenter Avenue Wheeling, IL 60090 (847) 541-3800 Website: www.elenco.com e-mail: elenco@elenco.com Copyright 2008
More informationAMM-1022 Digital Multimeter USER`S MANUAL
Digital Multimeter USER`S MANUAL www.tmatlantic.com CONTENTS 1. SAFETY INFORMATION.3 2. DESCRIPTION..6 3. SPECIFICATIONS.8 4. OPERATING INSTRUCTION..11 4.1 Voltage measurement...11 4.2 Current measurement
More informationOPERATOR S INSTRUCTION MANUAL
OPERATOR S INSTRUCTION MANUAL AUTO-RANGE DUAL DISPLAY CONFORMED IEC1010 DIGITAL MULTIMETER CONTENTS PAGE SAFETY INFORMATION..... DESCRIPTION.. OPERATING INSTRUCTION.. SPECIFICATIONS.... ACCESSORIES. BATTERY
More informationOPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER
OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER with Temperature Probe Copyright 2007 Elenco Electronics, Inc. Contents 1. Safety Information 3,4 2. Safety Symbols 5 3. Front Plate
More information1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10
CONTENTS 1. SAFETY INFORMATION.1 2. DESCRIPTION..4 3. SPECIFICATIONS.6 4. OPERATING INSTRUCTION..9 4.1 Voltage measurement...10 4.2 Current measurement 10 4.3 Resistance measurement...12 4.4 Diode test.12
More informationOWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER
OWNER S MANUAL HH0308C AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER IMPORTANT! Read and understand this manual before using the tester. Failure to understand and comply with safety rules and operating
More informationDIGITAL MULTIMETER OPERATING INSTRUCTIONS MODEL CDM-35. Part No
DIGITAL MULTIMETER MODEL CDM-35 Part No.4500055 OPERATING INSTRUCTIONS 0304 The Meter may be hung on a wall, or supported as shown, depending upon which support is used. The probes may be located as shown,
More informationAUTO RANGING DIGITAL MULTIMETER
AUTO RANGING DIGITAL MULTIMETER 12 MONTH WARRANTY LARGE DIGITAL DISPLAY AC/DC VOLTAGE & CURRENT MEASUREMENT CAT II SAFETY RATING CAT III TEST LEAD SAFETY RATING K8315 ED1 May 17 Table of Contents Know
More informationThank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at
ASTROAI USER MANUAL DT132A 4000 Count Auto-Ranging Multimeter Thank you for purchasing the AstroAI DT132A 4000 Count Auto-Ranging Multimeter. It is a 3 ¾ digit, 3999 counts, auto-ranging digital multimeter.
More informationDIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL
DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A TABLE OF CONTENTS TITLE PAGE Safety Information Safety Symbols... 1 Meter Description...
More informationUSER'S MANUAL DMR-4300
USER'S MANUAL DIGITAL MULTIMETER DMR-4300 CIRCUIT-TEST ELECTRONICS www.circuittest.com TABLE OF CONTENTS SAFETY Safety Information...................................... 2 Safety Symbols........................................
More informationDVM1190 DIGITAL MULTIMETER
DIGITAL MULTIMETER 1. Introduction Thank you for buying the. This digital multimeter has a large LCD, a data-hold function and a backlight. The device uses a very practical safety mechanism that keeps
More informationINSTRUCTION MANUAL MODEL 21 MULTI-TESTER
INSTRUCTION MANUAL MODEL 21 MULTI-TESTER 5 IN 1 SOUND LEVEL LIGHT HUMIDITY TEMPERATURE MULTIMETER .TABLET OF CONTENTS TITLE 1. INTRODUCTION 2 2. INFORMATION FOR SAFETY 2 3. FEATURES 4 4. SPECIFICATIONS
More informationOPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER
OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER SAFETY INFORMATION This multimeter has been designed according to IEC 1010 concerning electronic measuring instruments with an overvoltage category (CATⅡ)
More informationDIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL- KM 2782 / 2782-T
DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL- KM 2782 / 2782-T KM 2782 V 400A POWER G 17,Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA. Sales Direct : (022) 24156638 Tel. :
More informationUser s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130
User s Guide MultiView Series Digital MultiMeters Models: MV110 MV120 MV130 WARRANTY EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year
More informationDMM8900 SERIES USERS MANUAL
DMM8900 SERIES USERS MANUAL WARRANTY This instrument is warranted to be free from defects in material and workmanship for a period of one year. Any instrument found defective within one year from the delivery
More information1.General instructions Specifications Description...7
USER S Manual CONTENTS 1.General instructions...1 1.1 Precautions safety measures...1 1.1.1 Preliminary...1 1.1.2 During use...2 1.1.3 Symbols...4 1.1.4 Instructions...5 1.2 Protection mechanisms...6 2.
More informationSales: Technical: Fax:
DATA SHEET Order code Manufacturer code Description 85-0733 n/a n/a The enclosed information is believed to be correct, Information may change without notice due to product improvement. Users should ensure
More informationDIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.
MS8265 DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD ON/OFF LIGHT 1000V CAT II 600V CAT III MS8265 200K 2M 20M 20K 200M KHz 2K 20 200 2 20 200μ 200 20μ 750 2μ 1000 200n F 20n 10A 2m 200m 10 10
More informationOPERATING INSTRUCTION
OPERATING INSTRUCTION AUTOMOTIVE MULTIMETER MODEL QM1444 the finger guards on the probes. Measuring voltage which exceeds the limits of the multimeter may damage the meter and expose the operator to a
More informationHANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL
HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL GENERAL INSTRUCTIONS This instrument complies with IEC 1010-1 (61010-1@IEC: 2001), CAT. II 1000V and CAT. III 600V overvoltage standards. See Specifications.
More informationItem ref: UK MTM01 DIGITAL MULTITESTER. User Manual
Item ref: 600.100UK MTM01 DIGITAL MULTITESTER User Manual Please read this manual thoroughly and ensure all contents are fully understood before using the apparatus. Warning To avoid possible electric
More informationMW3105 DIGITAL CLAMP MULTIMETER
MW3105 DIGITAL CLAMP MULTIMETER 2 M MW3105 A 01 INTRODUCTION 1.1 - Unpacking and inspection Upon removing your new Digital Clamp Meter from its packing, you should have the following items: 1. Digital
More informationDIGITAL MULTIMETER. MODEL CDM-50 Part No OPERATING INSTRUCTIONS
DIGITAL MULTIMETER MODEL CDM-50 Part No.4500065 OPERATING INSTRUCTIONS 0607 DATA HOLD FUNCTION When this button is pressed, the last reading to be taken will be held on the display, and D-H will appear
More informationAC/DC CLAMP METER USER S MANUAL
AC/DC CLAMP METER USER S MANUAL CONTENTS PAGE SAFETY INFORMATION SYMBOL EXPLANATION SAFETY PRECAUTIONS 1 1 2 MAINTENANCE 3 GENERAL DESCRIPTION 4 PANEL DESCRIPTION 4 OPERATING INSTRUCTIONS... 7 SPECIFICATIONS
More informationDIGITAL CLAMP ON METER MODEL : 3600
SAFETY INFORMATION The following safety information must be obsered to insure maximum personal safety during the operation at this meter: 1. Do not use the meter if the meter or test leads look damaged,
More information1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS
To all residents of the European Union Important environmental information about this product This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm
More informationDVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding
BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER User Manual Gebruikershandleiding Manuel d'utilisation Gebrauchsanleitung Introduction BENCH MULTIMETER This manual
More informationUser s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter
User s Manual MiniTec TM Series Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter Introduction Congratulations on your purchase of Extech s MN26 Autoranging Multimeter. This
More informationINSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.
INSTRUCTION MANUAL Model 403380 Autoranging DMM ProbeMeter TM Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle. Back lit LCD with Autorange and full function displays Audible
More informationDIGITAL MULTIMETER INSTRUCTION MANUAL
DIGITAL MULTIMETER INSTRUCTION MANUAL 1 CONTENTS CONTENTS 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 1 1.2 DURING USE 2 1.3 SYMBOLS 3 1.4 MAINTENANCE 4 2. DESCRIPTION 5 2.1 NAMES OF COMPONENTS 5 2.2 SWITCH,
More informationNOTE: Fully read and understand this manual before using this Digital Multimeter.
ASTROAI USER MANUAL AUTO RANGING DIGITAL CLAMP METER Thank you for purchasing the Auto Ranging Digital Clamp Meter from AstroAI. The AstroAI Auto Ranging Digital Clamp Meter is designed to be safely and
More informationUser's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 800 Amp AC/DC True RMS Clamp Meter Model EX730 Introduction Congratulations
More informationETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL
ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL 1 1. SAFETY INFORMATION SAFETY SYMBOLS Warning! Dangerous Voltage (Risk of electric shock). Caution! Refer to the user s manual before using this
More informationDigital Multimeter with Backlight
MODEL: D03126 Digital Multimeter with Backlight 1 CONTENTS Page Number Description 3 Important Safety Information 3 What s Included? 4 Overview 4 Front Panel Description 5 General Specification 5 DC Voltage
More informationMS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL
MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL Table of Contents TITLE PAGE 1. GENERAL INSTRUCTIONS 1 1.1 Precaution safety measures 1 1.1.1 Preliminary 1 1.1.2 During use 2 1.1.3 Symbols
More information400Amp True RMS AC/DC Clamp Meter Model EX613
User's Guide 400Amp True RMS AC/DC Clamp Meter Model EX613 Introduction Congratulations on your purchase of this Extech EX613 True RMS Clamp Meter. This meter measures AC Current, DC Current, AC/DC Voltage,
More informationDIGIT & POINTER MULTIMETER
CONTENTS DIGIT & POINTER MULTIMETER OPERATOR S MANUAL 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 1 1.2 DURING USE 2 1.3 SYMBOLS 3 1.4 MAINTENANCE 3 2. DESCRIPTION 4 2.1 NAMES OF COMPONENTS 4 2.2 FUNCTION
More informationAutoranging Multimeter Extech EX503
User's Guide Autoranging Multimeter Extech EX503 Introduction Congratulations on your purchase of the Extech EX503 Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current, Resistance,
More informationGENERAL SPECIFICATIONS : Sensing : Average Sensing. Basic Accuracy : ±(0.8%rdg + 2dgt)
An ISO 9001:2008 Company SPECIAL FEATURES : Low power consumption CMOS double integration. A/D transform integrated circuit High Digital readings Auto Zero Calibration Instant continuity buzzer Average
More informationItem ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual
Item ref: 600.104UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE User Manual Please read this manual thoroughly and ensure all contents are fully understood before using the apparatus. WARNING
More informationEX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature
USER GUIDE True RMS Digital Multimeters EX350 Series EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature Table of Contents 1. INTRODUCTION 3 2. SAFETY INFORMATION 4 3.
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications
More informationDIGITAL MULTIMETER AX-588B
DIGITAL MULTIMETER AX-588B OPERATION MANUAL 1. Sumary His series product is a stable and battery-driven 3 ½ digital multimeter with high reliability. It adopts LCD screen with character height of 28mm;
More information400Amp True RMS AC Clamp Meter + NCV
User Guide 400Amp True RMS AC Clamp Meter + NCV Model MA410T Introduction Thank you for selecting the Extech MA410 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,
More informationModel DIGITAL MULTIMETER
Model 57070 DIGITAL MULTIMETER INSTRUCTION MANUAL SAFETY INFORMATION To ensure safe operation, and in order to exploit to the full the functionality of the meter, please follow the directions in this section
More informationHandheld Digital Multimeter PRO-50A
Handheld Digital Multimeter PRO-50A Safety Summary A statement calls attention to an operating procedure, practice, or condition, which, if not followed correctly, could result in injury or death to personnel.
More informationUser Manual Digital Multimeter
User Manual Digital Multimeter model no.: MSR-R500 Questions or Concerns? support@etekcity.com visit etekcity.com for more products Safe and Proper Usage Thank you for purchasing the Etekcity MSR-R500
More informationUser s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free
User s Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 400A AC/DC Clamp Meter Model MA220 Introduction Thank you for selecting
More informationUser Guide. Digital AC/DC Clamp Meter Model 38394
User Guide Digital AC/DC Clamp Meter Model 38394 Introduction Congratulations on your purchase of Extech s 38394 AC/DC Clamp Meter. This clamp meter measures AC/DC Current to 600A, DC/AC Voltage, Resistance,
More informationAnalog Technologies VC99. Multimeter FEATURES
FEATURES LCD Display Max Display: 6000(3 6/7) Digits Automatic Polarity, Unit Symbol and 61 Section Analog Display Measurement Method: Double Integral A/D Conversion Sampling Rate: Approx.3 times/sec Over-Range
More informationDM-45 Digital Multimeter
INSTRUCTION MANUAL DM-45 Digital Multimeter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Description The Greenlee DM-45 Digital
More informationUser s Guide. Digital AC/DC Clamp Meter Model 38394
User s Guide Digital AC/DC Clamp Meter Model 38394 Introduction Congratulations on your purchase of Extech s 38394 AC/DC Clamp Meter. This clamp meter measures AC/DC Current to 600A, DC/AC Voltage, Resistance,
More informationUSER'S MANUAL DMR-6700
USER'S MANUAL Multimeter True RMS DMR-6700 CIRCUIT-TEST ELECTRONICS www.circuittest.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),
More informationUSER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330
USER MANUAL Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330 Introduction Congratulations on your purchase of the Extech EX330 Meter. The EX330 offers AC/DC Voltage, AC/DC Current, Resistance,
More informationDIGITAL MULTIMETER 405
DIGITAL MULTIMETER 405 TAKE MEASUREMENT CAREFULLY AND YOU LL SPARE YOUR METER AND YOURSELF, SOME PAIN Nearly every electrical engineer has a hand held digital multimeter (DMM). We sometimes take them for
More informationMM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE
INSTRUCTION MANUAL Auto-Ranging Digital Multimeter MM400 DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE 600V 10A 40MΩ 2 GENERAL SPECIFICATIONS Klein Tools MM400 is an auto-ranging
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-352 The Service Information provides the following information: Precautions and safety information Specifications Basic maintenance (cleaning, replacing
More informationThe Meter Structure The Figure 2-1 shows the Meter structure.
P/N:110401104496X The Meter Structure The Figure 2-1 shows the Meter structure. 1. USB Terminals 2. LCD Display 3. Functional Buttons 4. Rotary Switch 5. Power adaptor Input Terminals 6. 10A Input Terminal
More informationUT207A/208A/209A Operating Manual. Table of Contents
Table of Contents Title Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Display Symbols Functional Buttons The Effectiveness
More informationContents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.
Contents 1. General instructions. 1.1 Precautions safety measures... 1.2 Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.2 LCD Display 2.3 Keypad. 3. Function description. 3.1
More informationCompact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)
User Manual Compact Autoranging Clamp Meters with NIST-Traceable Calibration Models 20250-55 (400 A AC), 20250-56 (400 A AC/DC) THE STANDARD IN PRECISION MEASUREMENT 1065DGMAN_20250-55,-56 DS Clamp Meter
More information770E DIGITAL MULTIMETER OPERATOR S MANUAL
770E DIGITAL MULTIMETER OPERATOR S MANUAL TABLE OF CONTENTS 1.Overview... 1 2.Panel Layout...1/2 3. Safety information... 2 4. Specical cautions for operation.... 2 5.General specifications...2/3 6.Testing
More informationMS2030 CAT III 600 V A V AUTO RS232
MS2030 AC Digital Clamp Meter User s Manual CAT III 600 V AUTO RS232 A V CONTENTS 1.Introduction...1 2.Safety Information...1 2.1 Precautions...1 2.2 Safety Symbols...3 3. Description...4 3.1 Front Panel...4
More informationSafety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.
9305 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates
More informationAC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español
Owner's Manual AC/DC Clamp Meter Model No. 82369 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español
More informationVC835 DIGTAL MULTIMETER Operation Manual
VC835 DIGTAL MULTIMETER Operation Manual CONTENTS GENERAL DESCRIPTION Safety Instructions FEATURES OPERATION MAINTENANCE TROUBLE SHOOTING 1. General Description This is a 3 1/2 digital multimeter with
More informationCD770 DIGITAL MULTIMETER INSTRUCTION MANUAL
CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL Table of Contents 1 SAFETY PRECAUTIONS Before use, read the following safety precautions.- 1-1 Explanation of Warning Symbols 001 1-2 Warning Messages for Safe
More informationUser s Guide. 400A AC/DC Clamp Meter. Model MA220
User s Guide 400A AC/DC Clamp Meter Model MA220 Introduction Thank you for selecting the Extech MA200 AC/DC Clamp Meter. This meter measures AC/DC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,
More informationUser Manual Digital Multimeter. model no.: MSR-U1000
User Manual Digital Multimeter model no.: MSR-U1000 This Operating Manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings and Notes
More informationUser's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330
User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330 Introduction Congratulations on your purchase of the Extech EX330 Meter. The EX330 offers AC/DC Voltage, AC/DC Current,
More informationUSER'S MANUAL DMR-4350
USER'S MANUAL DIGITAL MULTIMETER DMR-4350 CIRCUIT-TEST ELECTRONICS www.circuittest.com TABLE OF CONTENTS SAFETY Safety Information...................................... 2 Safety Symbols........................................
More informationUSER'S MANUAL DMR-2400
USER'S MANUAL DIGITAL MULTIMETER DMR-2400 CIRCUIT-TEST ELECTRONICS www.circuittest.com TABLE OF CONTENTS SAFETY Safety Information...................................... 2 Safety Symbols........................................
More informationR/C SMD Tweezers Multimeter Model RC200
User's Guide R/C SMD Tweezers Multimeter Model RC200 Introduction Congratulations on your purchase of the Extech RC200 RC Tweezers Multimeter This meter, using the tweezers adaptor, measures SMD capacitors,
More informationProfiScale MULTI Multimeter
1,5 V 9V 200 mv 600 V 200 ma 1/10 A ProfiScale MULTI Multimeter en Operating instructions BURG-WÄCHTER KG Altenhofer Weg 15 58300 Wetter Germany Introduction Want the reassurance of knowing whether current
More information200Amp AC Clamp Meter + NCV Model MA250
User's Guide 200Amp AC Clamp Meter + NCV Model MA250 Introduction Congratulations on your purchase of this Extech MA250 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance,
More informationDIGITAL MULTIMETER AUTORANGING
MODEL: D03124 DIGITAL MULTIMETER AUTORANGING 1 CONTENTS Page Number Details 2 Introduction 2 What s Included 3 Important Safety Information 3 Symbol Guide 4 Overview 5 Buttons 5 Display Indicators 6 General
More informationUSER S MANUAL DMR-1500
USER S MANUAL DIGITAL POCKET MULTIMETER DMR-1500 CIRCUIT-TEST ELECTRONICS www.circuittest.com TABLE OF CONTENTS SAFETY Safety Information............................... 2-3 Safety Symbols...................................
More informationATK Clamp Meter
ATK-2209 Clamp Meter User s Manual Title CONTENTS Page I. SAFETY INFORMATION... 1 II. TECHNICAL SPECIFICATIONS... 2 2-1 Environment Conditions... 2 2-2 Maintenance... 2 2-3 Features... 2 2-4 General Specifications...
More informationAgilent 970-Series Handheld Multimeters Data Sheet
Agilent 970-Series Handheld Multimeters Data Sheet Benchtop features and performance with handheld convenience and price 3 1 /2and 4 1 /2 digits with dcv accuracy to 0.05% 1 khz to 100 khz frequency response
More informationMS8216 DIGITAL MULTIMETER OPERATOR S MANUAL
MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL CONTENTS 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 1 1.2 DURING USE 2 1.3 SYMBOLS 4 1.4 MAINTENANCE 4 2. DESCRIPTION 5 2.1 NAMES OF COMPONENTS 5 2.2 FUNCTION AND
More informationAC68C. Users Manual. True RMS AC/DC Clamp Multimeter. PN July Amprobe Test Tools. All rights reserved.
AC68C True RMS AC/DC Clamp Multimeter Users Manual PN 2729051 July 2006 2006 Amprobe Test Tools. All rights reserved. Printed in Taiwan For detailed specifications and ordering info go to www.testequipmentdepot.com
More informationPCMT20 PYLE C;",D J WWWPYLEAUDIO.COM
PCMT20 PYLE C;",D J @~:@F WWWPYLEAUDIO.COM OPERATING INSTRUCTION AC CLAMP METER Safety International Safety Symbols ~ This symbol, adjacent to another symbol or terminal, indicates the user must refer
More informationMM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology
INSTRUCTION MANUAL Auto-Ranging Digital Multimeter er True RMS Measurement Technology MM700 DATA & RANGE HOLD LOW IMPEDANCE AUDIBLE CONTINUITY MIN / MAX / RELATIVE TEMPERATURE DIODE TEST CAPACITANCE &
More informationCompact MultiMeters + Voltage Detector
Compact MultiMeters + Voltage Detector Combination MultiMeters with Built-in Non-Contact AC Voltage Detector To quickly check for the presence of AC Voltage before testing EX300 Series Features: 0.5% basic
More information9015-A TRIPLETT. Model. Digital Multimeter. Instruction Manual
TRIPLETT Model 9015-A Digital Multimeter Instruction Manual Triplett Corporation One Triplett Drive Bluffton, OH 45817 800-TRIPLETT FAX: 419-358-7956 www.triplett.com Triplett Corporation All Rights Reserved
More informationMS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS
CONTENTS MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 2 1.2 DURING USE 3 1.3 SYMBOLS 5 1.4 MAINTENANCE 6 2. DESCRIPTION 8 2.1 NAMES OF COMPONENTS 9
More informationDigital Clamp Meter Model: &
Digital Clamp Meter Model: 72-7224 & 72-7226 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,
More information30XR-A Professional Digital Multimeter Users Manual
Professional Digital Multimeter Users Manual 99 Washington Street Melrose, MA 076 Fax 78-665-0780 TestEquipmentDepot.com MADE IN TAIWAN PATENTS PENDING www.amprobe.com MIN 5 00 00 0 0 00m 00m 00 0M m M
More informationBENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3
BENNING MODEL: MM1-1 / MM1-2 / MM1-3 Service Information The Service Information provides the following information: Precautions and safety information Specifications Basic maintenance (cleaning, replacing
More informationTrue RMS Digital Multimeter Model:
True RMS Digital Multimeter Model: 72-7780 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,
More informationUSER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com USER'S MANUAL ACDC-100 TRMS ACDC-100 Versatile AC/DC Clamp-on Multimeter Series 1 1) SAFETY This manual contains information
More informationUser Manual. All rights reserved. Specifications are subject to change without notice.
User Manual All rights reserved. Specifications are subject to change without notice. LIMITED WARRANTY AND LIMITATION OF LIABILITY Customers enjoy one-year warranty from the date of purchase. This warranty
More informationMETRAVI. Table of Contents
Table of Contents A. Your Meter s Feature B. Specifications C. Making Measurements D. Maintenance E. Accessories F. Using Holster G. Using Strap Introduction 540 is brand new Multimeter with 4 1/2 digits,
More information