DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL
|
|
- Antony Jonah Shaw
- 5 years ago
- Views:
Transcription
1 DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL
2
3 Warnings and Safety symbols: Caution, refer to this manual before using the meter. Dangerous voltages. Meter is protected throughout by double insulation or reinforced insulation. Comply with IEC When servicing, use only specified replacement parts. 1
4 TABLE OF CONTENTS 1.Features Panel Description Operation Instructions DC/AC Current Measurements DC/AC Voltage Measurements Resistance Measurement Continuity Measurement Change from Auto-range Mode to Manual Mode Relative Reading Measurements Holding the LCD Reading Finding the MAX/MIN Value Specifications Battery Replacement Maintenance & Cleaning
5 1.Features1.Features 1. Accurate DC/AC digital clamp meter for current measurement. 2. DC 2500A, AC 2100A (True RMS ). 3. φ55 mm diameter jaw. 4. One touch zero for DCA adjustment. 5. Auto-range for A, V, amd Ω. 6. Large 3 3/4 digits LCD 6. Fast bargraph display (20 times/sec.) for transient observation. 7. Continuity with buzzer. 8. Max/Min and Data Hold functions V overload protection for ohm measurement. 10. Easy single rotary switch for any function selection. 3
6 2. Panel Description. Panel Description 4
7 1. Transformer Jaw This is used to pick up a current signal. To measure DC/AC current, a conductor must be enclosed by the jaws. 2. Transformer Trigger This is used to open the jaws. 3. Data Hold Button Press this button to hold the current reading in the LCD display. Press it again to release the HOLD function. 4. Function Selection and On/Off Switch This is used to select the desired function, such as DCA, ACA, DCV, ACV, Hz, Ohm and Continuity. 5. Data Hold Symbol Once the hold button is pressed, this symbol appears in the LCD display. 6. Max/Min Hold Symbol Once the max/min button is pressed, either MAX or MIN shall be displayed on LCD 7. Units Symbols Once a function is selected, the corresponding unit (V, Ω, A, or Hz) shall be displayed on LCD. 8. LCD This is a 3 3/4 digit Liquid Crystal Display with maximum indication of Function symbols, units, bargraph, sign, decimal points, low battery symbols, max/min symbols, and zero symbol are included. 9. Zero/Relative Symbol When this symbol appears, it means a reference value has been subtracted from the actual reading. The reading shown is an offseted value. Press and hold the zero button for 2 seconds to disable this function. 10. Low Battery Symbol When this symbol appears, it indicates that the battery voltage has dropped below the minimum required voltage. Refer to Section V for battery replacement. 11. Analogue Bargraph The Bargraph has forty segments. It displays segments proportional to the actual reading. Each segment represent ten counts. 5
8 12. Relative Button Once this button is pressed, the current reading shall be set to zero and be used as a zero reference value for all other subsequent measurement. The function can also be used to offset readings caused by the residual magnetism remaining in the core for DC current measurements. Once this button is pressed, the clamp meter will change to manual mode instead of auto-range mode. The Relative function will be disabled if Max/Min function is enabled. 13 DCA ZERO button This button is used for DCA ZERO function. To zero the DCA residual value, press this button until the LCD displays zero. If the DCA ZERO button is used to zero a DCA value, the clamp meter is still in auto-range mode. ( It is different from the the relative button which forces the clamp meter change to manual mode.) 14. Max/Min Hold Button This button is used to enable the maximum or minimum value to be displayed and updated during measurement. Press it once and the minimum value shall be displayed and updated. Press it again and the maximum value shall be displayed and updated. Press it again (the third push) and the clamp meter returns to normal measurement mode. The Zero function will be disabled if MAX/MIN is enabled. 15. RANGE button Once the button is pressed, the clamp meter goes into manual mode. To select the desired range, press and release the button once. To return to the autorange mode, press and hold the button for more than 2 seconds. 16.COMTerminal This terminal is used as common reference input. 17.VΩ Input Terminal This terminal is used as an input for voltage, ohm/continuity, or frequency measurements. 6
9 3.Operation Instructions.Operation Instructions 3.1. DC/AC Current Measurements WARNING Make sure that all the test leads are disconnected from the meter s terminals for current measurement DC Current 7
10 a. Set the rotary switch at DCA. b. Push and hold the DCA ZERO button until the reading shows zero. c. Press the trigger to open the jaws and fully enclose the conductor to be measured. No air gap is allowed between the two half jaws. d. The clamp meter will automatically select the appropriate range. If the user wants to select a range manually, press the range button before pressing the DCA ZERO button. e. Read the measured value from the LCD display. Note There are two ways to zero the DCA residual value. Use the DCA zero button and the clamp meter is in auto-range mode. Use the REL button and the clamp meter will change to manual mode for DCA measurement AC Current 8
11 a. Set the rotary switch at ACA. b. In AC current measurement, ZERO is not needed. Do not press DCA ZERO button. c. Press the trigger to open the jaw and fully enclose the conductor to be measured. No air gap is allowed between the two half jaws. d. The clamp meter will automatically select proper range. If users want to select range, press the range button before pressing the DCA ZERO button. e. Read the measured value from the LCD display. 9
12 a. Set the rotary switch at ACA or DCA b. Analog signal is output from the bottom terminals at the same time. The output is proportional to the current measured (1mV/A). c. The red terminal is the positive while the black is the negative of the signal. d. Connect these two terminals to an oscilloscope or a datalogger, users can observe the current wave form or do the long term data recording DC/AC Voltage Measurements. TEST EQUIPMENT RISK ASSESSMENT (UK RECOMMENDATION) Users of this equipment and/or their employers are reminded that Health and Safety legislation requires them to carry out valid risk assessments of all electrical work so as to identify potential sources of electrical danger and risk of electrical injury such as from inadvertent short circuits. Where assessments show that the risk is significant then the use of fused test leads constructed in accordance with the HSE note GS38 Electrical Test Equipment for use by Electricians should be used. WARNING Maximum input for DC V is 1000, and for AC V is 750. Do not attempt to take any voltage measurement that exceeds the limits. Exceeding these limits could cause electrical shock and damage to the clamp meter DC Voltage a. Set the rotary switch to V DC. b. Insert the test leads into the input terminals. c. Connect the test probes of the test leads in PARALLEL to the circuit to be 10
13 measured. d. The clamp meter will automatically select the appropriate range. If manual selection of the range is required, press the range button. e. Read the measured value from the LCD display AC Voltage a. Set the rotary switch to V AC b. Insert the test leads into the input terminals. c. Connect the test probes of the test leads in PARALLEL to the circuit to be measured. d. The clamp meter will automatically select proper range. If users want to select range, press the range button. e. Read the measured value from the LCD display. WARNING Before taking any in-circuit resistance measurement, remove power from the circuit being tested and discharge all the capacitors Resistance Measurement Set the rotary switch to Ω Insert the test leads into the input terminals Connect the test probes of the test leads to the two ends of the resistor or circuit to be measured The clamp meter will automatically select proper range If manual selection of the range is required, press the range button Read the measured value from the LCD display Continuity Measurement Set the rotary switch to Continuity Insert the test leads into the input jack Connect the test prods of the test leads to the two ends of the resistor or circuit to be measured Read the measured value from the LCD display If the resistance is lower than 40 Ω, the internal sounder will operate. Diode Test a. Set the rotary switch to diode test. b. Insert the test leads to the input terminals 11
14 c. Connect the test probes of the test leads to the two ends of a diode d. Read the diode voltage from the LCD display 3.5 Frequency Measurement a. Set the rotary switch to Hz b. Insert the test leads to the input terminals c. Connect the test probes of the test leads to the circuit to be measurement. d. Adjust the voltage sensitivity by pressing RANGE button. The default sensitivity is 10mV. Pressing RANGE button will change the sensitivity to 100mV, or 1V. The sensitivity will be displayed momentarily when RANGE button is pressed. The higher the frequency, the highrer the sensitivity (such as 100mVor 1V) may be needed. If the sensitivity is set at 10mV, a stable reading might not be obtainable on the LCD display Relative Reading Measurements. The REL button can be used to make a relative measurement. Once the button is pushed, the current reading is set to zero and a zero symbol shall be displayed on LCD. All the subsequent measurement shall be displayed as a relative value with respect to the value being zeroed. Press the zero button for 2 seconds to return to normal mode. But this function is disabled if MAX/MIN function is enabled. Please watch for the symbol displayed on LCD Holding the LCD Reading Press the HOLD button, then the reading shall be held and kept on LCD Finding the MAX/MIN Value. Press the MAX/MIN button to enable the maximum and minimum values to be recorded and updated during measurement. Push the button once, the maximum value shall be displayed and updated. Push again (second push), the minimum value shall be displayed. Push again (third push), MAX/MIN function shall be disabled and return to the normal measurement mode. If MAX/MIN button is pressed, the ZERO function will be disabled and the ZERO symbol will disappear from LCD. 12
15 4. 23 C 5 C) DC Current: Range Resolution Accuracy (of rdg) Overload Protection 400A 0.1A 1.5% 3dgts DC 3000A A 1A 1.5% 3dgts DC 3000A A 1A 2.0% 3dgts DC 3000A AC Current (True RMS Crest Factor < 4): Range Resolution Accuracy (of rdg) Overload Protection 50/60 Hz 40-1KHz 400A 0.1A 1.5% 5dgts 2.0% 5dgts AC 3000A A 1A 2.0% 5dgts 2.5% 5dgts AC 3000A A 1A 2.5% 5dgts 3.0% 5dgts AC 3000A Current Analog Output Range Output Accuracy Overload Protection 0-400A 1mV/A 2.5% 0.5A 600V AC A 1mV/A 2.5% 5A 600V AC DC Voltage:(Autorange & Manual, Overload Protection 800VAC for all range) Range Resolution Accuracy(of rdg) Input Impedance 400mV 0.1mV 1.5% 3dgts 10MΩ 4V 0.001V 1.5% 3dgts 5MΩ 40V 0.01V 1.5% 3dgts 5MΩ 400V 0.1V 1.5% 3dgts 5MΩ 600V 1V 1.5% 3dgts 5MΩ 13
16 14
17 AC Voltage(True RMS, Crest Factor < 4) (Autorange & Manual, Overload Protection 800VAC for all range) Range Resolution Accuracy (of reading) Input Impedance 50/60 Hz 40-1KHz 400mV 0.1mV V % 5dgts 2.0% 5dgts 5MΩ 40V 0.01V 1.5% 5dgts 2.0% 5dgts 5MΩ 400V 0.1V 1.5% 5dgts 2.0% 5dgts 5MΩ 600V 1V 1.5% 5dgts 2.0% 5dgts 5MΩ 1 Though 400mVAC can be selected by RANGE key, it is not designed to measured AC mv. So no accuracy is listed for AC 400mV range. Resistance Ω (Autorange & Manual, Open Circuit Voltage 0.5V) Range Resolution Accuracy (of reading) Overload Protection 400Ω 0.1Ω 1.5% 3dgts 600VAC 4KΩ 1Ω 1.5% 3dgts 600VAC 40KΩ 10Ω 1.5% 3dgts 600VAC 400KΩ 100Ω 1.5% 3dgts 600VAC 4MΩ 1KΩ 1.5% 3dgts 600VAC 40MΩ 10KΩ 1.5% 3dgts 600VAC Resistance (Ω) and Continuity:(open voltage 0.4V) Range Resolution Accuracy Beeping OL Protection Ω 0.1Ω 1.0% rdg 2dgts < 40.0 Ω (approx.) AC 600V 15
18 Diode Test Range Resolution Accuracy Overload Protection 3V 0.001V 2.5% 5dgts 600VAC Frequency (Hz, Overload Protection 600VAC, Sensitivity selected by RANGE button) Range Resolution Accuracy Sensitivity 100Hz 1000KHz 0.01Hz - 100Hz 0.5% 2dgts 10mV/100mV/1V 16
19 Indoor Use Conductor Size :Cable Φ55mm. (approx.) Bus Bar 65mm(D) x 24mm(W) Battery Type Display Range Selection Overload Indication Power Consumption : 9V : 3 3/4 LCD with 40 seg. bargraph : Auto and manual : left most digit blinks : 12 ma (approx.) Low battery Indication : B Sampling Time : 2 times/sec. (display) 20 times/sec. (bargraph) Operating Temperature : 4 C to 50 C Operating Humidity Altitude : less than 85% relative : up to 2000M Storage Temperature : -20 C to 60 C Storage Humidity : less than 75% relative Dimension : 271mm (L) x 112mm (W) x 46mm (H) 10.7" (L) x 4.4" (W) x 1.8" (H) Weight : 647 g/22.8 oz (batteries included) Accessories : Carrying bag x 1 Users manual x 1 9V battery x 1 17
20 5.Battery Replacement When the low battery symbol is displayed on the LCD, replace the old battery with a new battery. 5.1.Turn the power off and remove the test leads from the clamp meter. 5.2.Remove the screws from the bottom half of the case. 5.3.Lift and remove the bottom half of the case. 5.4.Remove the old battery. 5.5.Insert new 9V battery. 5.6.Replace the bottom half of the case and secure the screws. WARNING Do not touch or adjust any parts inside the clamp meter when the bottom case is open. 18
21 6. Maintenance & Cleaning Servicing not covered in this manual should only be performed by qualified personnel. Repairs should only be performed by qualified personnel. Periodically wipe the case with a damp cloth and detergent; do not use abrasives or solvents. 19
DM-46 Instruction Manual
Auto Meter Products Inc. Test Equipment DM-46 Instruction Manual Automotive Multimeter and Inductive Amp Probe The DM-46 is the auto industry s answer to pocket portability in a 20 2650-1552-00 3/8/11
More informationDM-46 Instruction Manual
Test Equipment Auto Meter Products Inc. 413 West Elm Street Sycamore, IL 60178 Service (815) 899-0801 Toll Free (866) 883-TEST (8378) www.autometer.com/test DM-46 Instruction Manual Automotive Multimeter
More informationInstruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES
Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES TABLE OF CONTENTS / EN TITLE TABLE OF CONTENTS PAGE 1. SAFETY INFORMATION... 1 2. TECHNICAL SPECIFICATIONS... 2 3. PARTS & CONTROLS...
More informationUser s Guide. Digital AC/DC Clamp Meter Model 38394
User s Guide Digital AC/DC Clamp Meter Model 38394 Introduction Congratulations on your purchase of Extech s 38394 AC/DC Clamp Meter. This clamp meter measures AC/DC Current to 600A, DC/AC Voltage, Resistance,
More informationUser Guide. Digital AC/DC Clamp Meter Model 38394
User Guide Digital AC/DC Clamp Meter Model 38394 Introduction Congratulations on your purchase of Extech s 38394 AC/DC Clamp Meter. This clamp meter measures AC/DC Current to 600A, DC/AC Voltage, Resistance,
More informationET-3888 True RMS Clamp Meter. User Manual
ET-3888 True RMS Clamp Meter User Manual Index Introduction... 3 Safety Notes... 4 Features... 5 Specifications... 6-8 Instrument Layout... 9 Measurement... 10 Maintenance... 11 Page 2 1. Introduction
More informationUser Guide. AC/DC Mini Clamp Meter. Model
User Guide AC/DC Mini Clamp Meter Model 380941 P Introduction Congratulations on your purchase of Extech s AC/DC Clamp Meter. This professional meter, with proper care, will provide years of safe reliable
More informationATK Clamp Meter
ATK-2209 Clamp Meter User s Manual Title CONTENTS Page I. SAFETY INFORMATION... 1 II. TECHNICAL SPECIFICATIONS... 2 2-1 Environment Conditions... 2 2-2 Maintenance... 2 2-3 Features... 2 2-4 General Specifications...
More informationPen-type DIGITAL MULTITESTER
BST-MT267 Pen-type DIGITAL MULTITESTER INSTRUCTION MANUAL Index 1. Introduction... 2. Safety Notes... 3. Features... 4. Specifications... 5. General... 6. Instrument Layout... 7. Measurement... 8. Maintenance...
More informationModel True RMS AC/DC 30A Mini Clamp-on Meter. User Guide
Model 380942 True RMS AC/DC 30A Mini Clamp-on Meter User Guide Introduction Congratulations on your purchase of the Extech Model 380942 DC/AC Clamp Meter. This meter is shipped fully tested and calibrated
More informationInstruction Manual IPM φ/1φ Power Clampmeter EN FR IT DE ES
Instruction Manual IPM 6600 3φ/1φ Power Clampmeter EN FR IT DE ES 0 EN 61010-2-032 CAT III 600V Pollution Degree 2 Definition of Symbols: Caution: Refer to Accompanying Documents Caution: Risk of Electric
More informationAM
Us e rmanual Di gi t almul t i me t e r AM1109 EN 61010-1 CAT III 1000V Pollution Degree 2 Definition of Symbols: Caution: Refer to Accompanying Documents Caution: Risk of Electric Shock Double Insulation
More informationAC/DC CLAMP METER USER S MANUAL
AC/DC CLAMP METER USER S MANUAL CONTENTS PAGE SAFETY INFORMATION SYMBOL EXPLANATION SAFETY PRECAUTIONS 1 1 2 MAINTENANCE 3 GENERAL DESCRIPTION 4 PANEL DESCRIPTION 4 OPERATING INSTRUCTIONS... 7 SPECIFICATIONS
More informationOPERATOR S INSTRUCTION MANUAL
OPERATOR S INSTRUCTION MANUAL AUTO-RANGE DUAL DISPLAY CONFORMED IEC1010 DIGITAL MULTIMETER CONTENTS PAGE SAFETY INFORMATION..... DESCRIPTION.. OPERATING INSTRUCTION.. SPECIFICATIONS.... ACCESSORIES. BATTERY
More informationModel: Pro95 TRUE RMS MILLIAMP CLAMP METER
Model: Pro95 TRUE RMS MILLIAMP CLAMP METER TABLE OF CONTENTS 1. SAFETY INFORMATION... 1 2. GENERAL SPECIFICATION... 1 3. ELECTRICAL SPECIFICATION... 2 3-1 ACMA MEASUREMENT... 2 3-2 ACA MEASUREMENT...
More informationDVM1190 DIGITAL MULTIMETER
DIGITAL MULTIMETER 1. Introduction Thank you for buying the. This digital multimeter has a large LCD, a data-hold function and a backlight. The device uses a very practical safety mechanism that keeps
More informationNOTE: Fully read and understand this manual before using this Digital Multimeter.
ASTROAI USER MANUAL AUTO RANGING DIGITAL CLAMP METER Thank you for purchasing the Auto Ranging Digital Clamp Meter from AstroAI. The AstroAI Auto Ranging Digital Clamp Meter is designed to be safely and
More informationDigital Clamp Meter Model: &
Digital Clamp Meter Model: 72-7224 & 72-7226 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,
More information400Amp True RMS AC/DC Clamp Meter Model EX613
User's Guide 400Amp True RMS AC/DC Clamp Meter Model EX613 Introduction Congratulations on your purchase of this Extech EX613 True RMS Clamp Meter. This meter measures AC Current, DC Current, AC/DC Voltage,
More informationCONTENTS MS2033A. 1.Introduction Safety Information...01
MS2033A AC Digital Clamp Meter User s Manual CAT III 600 V CONTENTS 1.Introduction...01 2.Safety Information...01 2.1 Precautions...02 2.2 Safety Symbols...03 3. Description...04 3.1 Front Panel...04 3.2
More informationOPERATOR S INSTRUCTION MANUAL
2 OPERATOR S INSTRUCTION MANUAL CLAMP METER HOLD 20 A 200 A 2 A 600 600 LIGHT ON/OFF Digital Clamp Meter 2 20 200 A khz COM CAT.II MAX 600 CONTENTS 1. General instruction.....1 2. Description...1 2.1 Precautions
More informationUSER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com USER'S MANUAL ACDC-100 TRMS ACDC-100 Versatile AC/DC Clamp-on Multimeter Series 1 1) SAFETY This manual contains information
More informationDIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL
DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A TABLE OF CONTENTS TITLE PAGE Safety Information Safety Symbols... 1 Meter Description...
More informationUser Manual Digital Clamp Multimeter. model no.: MSR-C600
User Manual Digital Clamp Multimeter model no.: MSR-C600 Overview This Operating Manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings
More informationUT207A/208A/209A Operating Manual. Table of Contents
Table of Contents Title Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Display Symbols Functional Buttons The Effectiveness
More informationUser s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free
User s Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 400A AC/DC Clamp Meter Model MA220 Introduction Thank you for selecting
More informationMODEL: D03128 CLAMP METER
MODEL: D03128 CLAMP METER 1 CONTENTS Page Number Details 3 Important Safety Information 3 Features 4 Product Overview 5 Switches, Buttons & Input Jacks 5 LCD 6 Specifications 6 Electrical Specifications
More informationUser's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 800 Amp AC/DC True RMS Clamp Meter Model EX730 Introduction Congratulations
More informationCompact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)
User Manual Compact Autoranging Clamp Meters with NIST-Traceable Calibration Models 20250-55 (400 A AC), 20250-56 (400 A AC/DC) THE STANDARD IN PRECISION MEASUREMENT 1065DGMAN_20250-55,-56 DS Clamp Meter
More informationAC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual
AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30 Handleiding / Manual INTRODUCTION 1-1 Unpacking and Inspection Upon removing your new Digital Clamp Multimeter from its packing, you should
More informationAC/DC DIGITAL CLAMP METER OPERATION MANUAL
AC/DC DIGITAL CLAMP METER OPERATION MANUAL HYS005661 A0 ACCESSORIES 6. ACCESSORIES 1) Test Leads: Electric Ratings 1000V 10A 1 pair (set) 2) Operating Manual 1 copy 3) 1.5V AAA Battery 3 piece - - 55 -
More informationUser s Guide. 400A AC/DC Clamp Meter. Model MA220
User s Guide 400A AC/DC Clamp Meter Model MA220 Introduction Thank you for selecting the Extech MA200 AC/DC Clamp Meter. This meter measures AC/DC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,
More informationMultifunction Digital
MS2009A Multifunction Digital Clamp Meter User Manual 200/600 OFF 2/20 NCV SEL MAX V RAN HOLD OFF MS2009A AC CLAMP METER AUTO MAX C F kmω μmva CONTENTS Safety requirements...1 Safety signs...1 Notes...1
More informationDIGITAL MULTIMETER AUTORANGING
MODEL: D03124 DIGITAL MULTIMETER AUTORANGING 1 CONTENTS Page Number Details 2 Introduction 2 What s Included 3 Important Safety Information 3 Symbol Guide 4 Overview 5 Buttons 5 Display Indicators 6 General
More informationDL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter
DL6508 User's Guide 1500Amp True RMS AC/DC Clamp Meter Introduction Congratulations on your purchase of this DL6508 True RMS Clamp Meter. This meter measures AC Current, DC Current, AC/DC Voltage, Resistance,
More informationUser Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph
User Guide AC/DC Mini Clamp Meter Model 380941 Large 3 3/4 digit LCD display with 40 segment bargraph Continuity and Frequency Measurements One touch DCA zero adjust MIN/MAX and Data Hold functions 0.9
More information312, 316, 318. Clamp Meter. Users Manual
312, 316, 318 Clamp Meter Users Manual PN 1989445 July 2002 Rev.2, 2/06 2002, 2006 Fluke Corporation. All rights reserved. Printed in China. All product names are trademarks of their respective companies.
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications
More informationOWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER
OWNER S MANUAL HH0308C AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER IMPORTANT! Read and understand this manual before using the tester. Failure to understand and comply with safety rules and operating
More informationAC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325
AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325 CONTENTS 1. FEATURES... 2 2. Safety precaution... 2 Symbols Description... 3 3. Specifications... 4 4. Electrical Specifications...
More informationINSTRUCTION MANUAL IDM17 PEN-TYPE MULTIMETER
INSTRUCTION MANUAL IDM17 PEN-TYPE MULTIMETER EN FR IT DE IDM 17 PEN-TYPE MULTIMETER INSTRUCTION MANUAL 1 2 INTRODUCTION 1-1 Unpacking and Inspection Upon removing your new Digital Multimeter from its packing,
More informationAC Clamp Meter + Phase Rotation Tester
User's Manual AC Clamp Meter + Phase Rotation Tester Model 380974 Hz Introduction Congratulations on your purchase of the Extech 380974 AC Clamp Meter + Phase Rotation Tester. This professional 1000A Clamp
More informationOPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER
OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER with Temperature Probe Copyright 2007 Elenco Electronics, Inc. Contents 1. Safety Information 3,4 2. Safety Symbols 5 3. Front Plate
More informationOPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER
OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER SAFETY INFORMATION This multimeter has been designed according to IEC 1010 concerning electronic measuring instruments with an overvoltage category (CATⅡ)
More informationUser's Manual. Clamp-on Power Datalogger. Model
User's Manual Clamp-on Power Datalogger Model 382060 WARRANTY EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a
More informationUser's Guide Extech EX Amp Clamp Meter with IR Thermometer
User's Guide Extech EX810 1000 Amp Clamp Meter with IR Thermometer Patented Introduction Congratulations on your purchase of the Extech EX810 Clamp Meter. This meter measures AC/DC Voltage, AC Current,
More informationUSER MANUAL 600A AC Clamp Meter + NCV Model MA610
USER MANUAL 600A AC Clamp Meter + NCV Model MA610 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech MA610 Clamp Meter. This meter measures
More informationDVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use
True RMS Digital Multimeter DVM98 1 Safety information This multimeter has been designed according to IEC - 1010 concerning electronic measuring instruments with an overvoltage category (CAT II) and pollution
More informationSales: Technical: Fax:
DATA SHEET Order code Manufacturer code Description 85-0733 n/a n/a The enclosed information is believed to be correct, Information may change without notice due to product improvement. Users should ensure
More informationVC835 DIGTAL MULTIMETER Operation Manual
VC835 DIGTAL MULTIMETER Operation Manual CONTENTS GENERAL DESCRIPTION Safety Instructions FEATURES OPERATION MAINTENANCE TROUBLE SHOOTING 1. General Description This is a 3 1/2 digital multimeter with
More informationTrue RMS AC / DC Power Clamp Meter Model
User's Guide True RMS AC / DC Power Clamp Meter Model 380940 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment
More informationKMD-S04 Multímetro de bolsillo
www.grupotemper.com KMD-S04 Multímetro de bolsillo Table of Contents Title Page Overview ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 3 Unpacking Inspection ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 4 Safety Information
More informationCM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH
AC/DC LOW CURRENT CLAMP-ON METER CM605 ENGLISH User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments
More informationMS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual
DUAL DISPLAY DIGITAL MULTIMETER User s Manual MS8250D 1. Safety Information Warning Use caution and follow all safety guidelines to prevent electric shock or damage to the meter. Please ready carefully
More informationModel ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com
Model ST-9933 True RMS Autoranging Digital Multimeter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-8 Technical...4-5 Accuracy...5-8 Display Description...
More informationSAFETY PRECAUTIONS: Before use, read the following safety precautions
[1] SAFETY PRECAUTIONS: Before use, read the following safety precautions This instruction manual explains how to use your multimeter CD731, CD751 safely. Before use, please read this manual thoroughly.
More informationNot for Reproduction
1 ADVANCE PRODUCT SERVICE INFORMATION SUBJECT: OPERATING PROCEDURES FOR EXTECH DIGITAL MULTIMETER No: #66 DATE: 05/31/2010 MODELS: 19602 DIGITAL MULTIMETER A digital multimeter is necessary for electrical
More information1.General instructions Specifications Description...7
USER S Manual CONTENTS 1.General instructions...1 1.1 Precautions safety measures...1 1.1.1 Preliminary...1 1.1.2 During use...2 1.1.3 Symbols...4 1.1.4 Instructions...5 1.2 Protection mechanisms...6 2.
More information400Amp True RMS AC Clamp Meter + NCV
User Guide 400Amp True RMS AC Clamp Meter + NCV Model MA410T Introduction Thank you for selecting the Extech MA410 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,
More information1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS
To all residents of the European Union Important environmental information about this product This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm
More informationItem ref: UK MTM01 DIGITAL MULTITESTER. User Manual
Item ref: 600.100UK MTM01 DIGITAL MULTITESTER User Manual Please read this manual thoroughly and ensure all contents are fully understood before using the apparatus. Warning To avoid possible electric
More informationINSTRUCTION MANUAL ACD-10 PRO & TRMS PRO
INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO AMPROBE 1 Congratulations! You are now the owner of an AMPROBE Instrument. It has been quality crafted according to quality standards and contains quality components
More informationUSER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series
USER'S MANUAL ACD-6 Pro ACD-6 TRMS Pro Versatile Clamp-on Multimeter Series 1 1) SAFETY This manual contains information and warnings that must be followed for operating the instrument safely and maintaining
More informationDigital Clamp Meter (TRMS) Model : 2727
Digital Clamp Meter (TRMS) Model : 2727 Instruction Manual 1. SPECIFICATIONS 1.1 General Specifications Display : 3 ¾ digit liquid crystal display (LCD) with a maximum reading of 3999. Polarity : Automatic,
More informationTrue RMS Digital Multimeter Model:
True RMS Digital Multimeter Model: 72-7780 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,
More informationMS8223A. CAT.IIi 600 V
Pen-type Digital Multimeter Manual MS8223A CAT.IIi 600 V CONTENTS 1. Safety Information......1 1.1 Preparing for use...1 1.2 During Use......2 1.3 Safety Symbols...3 1.4 Maintenance...4 2. Description......4
More information200Amp AC Clamp Meter + NCV Model MA250
User's Guide 200Amp AC Clamp Meter + NCV Model MA250 Introduction Congratulations on your purchase of this Extech MA250 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance,
More informationMW3105 DIGITAL CLAMP MULTIMETER
MW3105 DIGITAL CLAMP MULTIMETER 2 M MW3105 A 01 INTRODUCTION 1.1 - Unpacking and inspection Upon removing your new Digital Clamp Meter from its packing, you should have the following items: 1. Digital
More informationModel: &
600A True RMS Digital Clamp Meter Model: 72-3097 & 72-3099 1 CONTENTS Page Number Details 3 Important Safety Information 4 Product overview 4 Key Functions 5 General Specification 5 Electrical Specification
More informationDVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding
BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER User Manual Gebruikershandleiding Manuel d'utilisation Gebrauchsanleitung Introduction BENCH MULTIMETER This manual
More informationDigital Multi Meter OPERATING INSTRUCTION. Table of Contents
Table of Contents Digital Multi Meter OPERATING INSTRUCTION 1. Introduction 2. Safety note 3. Explanation of Controls and Indicators 3-1. Product illustration 3-2. Functional push button 3-3. LCD display
More informationUser's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer
User's Guide Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer EX810 AC Clamp meter EX820 True RMS AC Clamp meter EX830 AC/DC True RMS Clamp meter Patented Introduction Congratulations on your
More informationUSER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM
USER MANUAL Model MA440 400A AC Clamp Meter DMM Model MA443 True RMS 400 AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM Introduction Thank you for selecting the Extech EX44x Series
More informationEX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature
USER GUIDE True RMS Digital Multimeters EX350 Series EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature Table of Contents 1. INTRODUCTION 3 2. SAFETY INFORMATION 4 3.
More informationAC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español
Owner's Manual AC/DC Clamp Meter Model No. 82369 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español
More informationThank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at
ASTROAI USER MANUAL DT132A 4000 Count Auto-Ranging Multimeter Thank you for purchasing the AstroAI DT132A 4000 Count Auto-Ranging Multimeter. It is a 3 ¾ digit, 3999 counts, auto-ranging digital multimeter.
More informationLH240 LH1040 LH2040 LH2015
LH240 LH1040 LH2040 LH2015 AC/DC Clamp On Multimeters Pinces Multimétriques AC/DC AC/DC Zangen-Multimeter Multimetri tenaglia c.a./c.c. Multímetros de inserción de C.A./C.C. Operating Instructions Mode
More informationUT207/208. Digital Clamp Multimeter P/N:
UT207/208 Digital Clamp Multimeter P/N: 41451522 Model UT207/208 OPERATING MANUAL Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical
More information400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623
User's Guide 400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623 Introduction Congratulations on your purchase of this Extech EX623 True RMS Clamp Meter. This meter measures AC Current, DC
More informationMini Clamp Meter Model:
Mini Clamp Meter Model: 72-2985 1 CONTENTS Page Number Details 2 What s Included 3 Important Safety Information 3 Technical Specification 4 Product Overview 5 LCD Overview 6 Operation - AC/DC Voltage Measurement
More information600A Clamp Meters w/tightsight Display
V 750V #61-764 #61-766 #61-768 600A Clamp Meters w/tightsight Display Instruction Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com CAT.IV 600V CAT.III 1000V 600A 61-766
More informationThe Meter Structure The Figure 2-1 shows the Meter structure.
P/N:110401104496X The Meter Structure The Figure 2-1 shows the Meter structure. 1. USB Terminals 2. LCD Display 3. Functional Buttons 4. Rotary Switch 5. Power adaptor Input Terminals 6. 10A Input Terminal
More informationPen Multimeter. Model
Pen Multimeter Model 381626 CAUTION: Read, understand and follow all Safety Rules and Operating Instructions in this manual before using this product. This instrument is a 3200 count pen style digital
More informationMS2030 CAT III 600 V A V AUTO RS232
MS2030 AC Digital Clamp Meter User s Manual CAT III 600 V AUTO RS232 A V CONTENTS 1.Introduction...1 2.Safety Information...1 2.1 Precautions...1 2.2 Safety Symbols...3 3. Description...4 3.1 Front Panel...4
More informationDIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS
CONTENTS CONTENTS CONTENTS 1. SAFETY INFORMATION...1 1.1 Preliminary...1 1.2 Dos and don ts...2 1.3 Symbols...3 1.4 Precautions...4 2. DESCRIPTION...5 2.1 Names of parts...6 2.2 Switches, buttons and input
More informationContents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.
Contents 1. General instructions. 1.1 Precautions safety measures... 1.2 Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.2 LCD Display 2.3 Keypad. 3. Function description. 3.1
More informationAMM-1022 Digital Multimeter USER`S MANUAL
Digital Multimeter USER`S MANUAL www.tmatlantic.com CONTENTS 1. SAFETY INFORMATION.3 2. DESCRIPTION..6 3. SPECIFICATIONS.8 4. OPERATING INSTRUCTION..11 4.1 Voltage measurement...11 4.2 Current measurement
More informationR/C SMD Tweezers Multimeter Model RC200
User's Guide R/C SMD Tweezers Multimeter Model RC200 Introduction Congratulations on your purchase of the Extech RC200 RC Tweezers Multimeter This meter, using the tweezers adaptor, measures SMD capacitors,
More informationDCM730. Digital Clamp Meter User s Manual
DCM730 Digital Clamp Meter User s Manual Table of Contents LIMITED WARRANTY AND LIMITATION OF LIABILITY...1 Out of the Box...1 Safety Information...2 INTRODUCTION...4 Components and Buttons...6 Names of
More informationUser Manual Digital Multimeter. model no.: MSR-U1000
User Manual Digital Multimeter model no.: MSR-U1000 This Operating Manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings and Notes
More informationTRMS LEAKAGE CURRENT CLAMP-ON METER 565
TRMS LEAKAGE CURRENT CLAMP-ON METER 565 E N G L I S H User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards
More informationDigital Clamp Meter. User Manual
Digital Clamp Meter User Manual CM240 WWW.OWON.COM.CN Mar. 2016 edition V1.2 Copyright LILLIPUT Company. All rights reserved. The LILLIPUT's products are under the protection of the patent rights, including
More information1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10
CONTENTS 1. SAFETY INFORMATION.1 2. DESCRIPTION..4 3. SPECIFICATIONS.6 4. OPERATING INSTRUCTION..9 4.1 Voltage measurement...10 4.2 Current measurement 10 4.3 Resistance measurement...12 4.4 Diode test.12
More informationModel UT10A: OPERATING MANUAL Table of Contents (1)
Table of Contents (1) Table of Contents Title Page Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Functional Buttons Measurement
More informationICM 136R Operating Instruction Electrical Clamp-Multimeter
ICM 136R Operating Instruction Electrical Clamp-Multimeter Safety Information For safe operation of this clamp-multimeter, read these instructions completely before you use it and comply with them fully.
More informationPEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D
PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D T8211D 1 1. SAFETY INFORMATION BE EXTREMELY CAREFUL IN THE USE OF THIS METER. Improper use of this device can result in electric shock or destroy of
More informationMS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual
DUAL DISPLAY DIGITAL MULTIMETER User s Manual MS8250D Introduction MS8250D is a stable, safe, reliable compact digital handheld 6600 count, True RMS, auto-ranging multimeter. This meter can measure AC/DC
More informationInstruction Manual ICM A9 Electrical Clamp Multimeter EN FR IT DE ES
Instruction Manual ICM A9 Electrical Clamp Multimeter EN FR IT DE ES ICM A9 Warning...................................... Safety.............................................. Read First Safety Information
More informationDIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.
MS8265 DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD ON/OFF LIGHT 1000V CAT II 600V CAT III MS8265 200K 2M 20M 20K 200M KHz 2K 20 200 2 20 200μ 200 20μ 750 2μ 1000 200n F 20n 10A 2m 200m 10 10
More informationUSER S MANUAL DMR-1500
USER S MANUAL DIGITAL POCKET MULTIMETER DMR-1500 CIRCUIT-TEST ELECTRONICS www.circuittest.com TABLE OF CONTENTS SAFETY Safety Information............................... 2-3 Safety Symbols...................................
More information